@oimlsmart/primmel-packages 0.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (460) hide show
  1. package/AGENTS.md +60 -0
  2. package/LICENSE +21 -0
  3. package/README.md +68 -0
  4. package/acme-cgm-200/model/cgm200.prl +284 -0
  5. package/acme-cgm-200/model/r144-map.prl +337 -0
  6. package/acme-cgm-200/package.primmel +39 -0
  7. package/acme-cgm-system/model/cgm-system.prl +125 -0
  8. package/acme-cgm-system/model/r144-map.prl +75 -0
  9. package/acme-cgm-system/model/sample-line.prl +42 -0
  10. package/acme-cgm-system/package.primmel +23 -0
  11. package/acme-lc500/model/lc500.prl +218 -0
  12. package/acme-lc500/model/passport.prl +43 -0
  13. package/acme-lc500/model/r60-map.prl +161 -0
  14. package/acme-lc500/model/twin-cert-map.prl +114 -0
  15. package/acme-lc500/package.primmel +35 -0
  16. package/acme-md3xx/model/md350.prl +317 -0
  17. package/acme-md3xx/model/r129-map.prl +346 -0
  18. package/acme-md3xx/package.primmel +49 -0
  19. package/acme-rs180/model/r91-map.prl +234 -0
  20. package/acme-rs180/model/rs180.prl +236 -0
  21. package/acme-rs180/package.primmel +47 -0
  22. package/ims-demo/model/ims.prl +23 -0
  23. package/ims-demo/model/isms-map.prl +60 -0
  24. package/ims-demo/model/qms-map.prl +73 -0
  25. package/ims-demo/package.primmel +42 -0
  26. package/isms-ref/model/isms.prl +34 -0
  27. package/isms-ref/package.primmel +35 -0
  28. package/iso-iec-17000/package.primmel +8 -0
  29. package/iso-iec-17000/terminology.prl +268 -0
  30. package/iso-iec-17025/package.primmel +10 -0
  31. package/iso-iec-17025/specification/requirements/lab.prl +474 -0
  32. package/iso-iec-17025/terminology.prl +72 -0
  33. package/iso-iec-17065/package.primmel +10 -0
  34. package/iso-iec-17065/specification/requirements/body.prl +446 -0
  35. package/iso-iec-17065/terminology.prl +103 -0
  36. package/iso-iec-17067/package.primmel +10 -0
  37. package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
  38. package/iso-iec-17067/terminology.prl +24 -0
  39. package/oiml-cs/package.primmel +10 -0
  40. package/oiml-cs/specification/discrepancies.prl +26 -0
  41. package/oiml-cs/specification/requirements/cs.prl +515 -0
  42. package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
  43. package/oiml-cs-dataspace/package.primmel +9 -0
  44. package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
  45. package/oiml-cs-dataspace/specification/policies.prl +68 -0
  46. package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
  47. package/oiml-integrated-ref/package.primmel +10 -0
  48. package/oiml-r129/.primmel-allowlist.prl +2 -0
  49. package/oiml-r129/evaluation/processes.prl +152 -0
  50. package/oiml-r129/evaluation/workflow.prl +48 -0
  51. package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
  52. package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
  53. package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
  54. package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
  55. package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
  56. package/oiml-r129/execution/forms/admin/identification.prl +49 -0
  57. package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
  58. package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
  59. package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
  60. package/oiml-r129/execution/forms/emc/esd.prl +66 -0
  61. package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
  62. package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
  63. package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
  64. package/oiml-r129/execution/forms/emc/surge.prl +61 -0
  65. package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
  66. package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
  67. package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
  68. package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
  69. package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
  70. package/oiml-r129/execution/forms/shared/headers.prl +86 -0
  71. package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
  72. package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
  73. package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
  74. package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
  75. package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
  76. package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
  77. package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
  78. package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
  79. package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
  80. package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
  81. package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
  82. package/oiml-r129/layers.prl +50 -0
  83. package/oiml-r129/model/attributes.prl +243 -0
  84. package/oiml-r129/model/behaviors.prl +79 -0
  85. package/oiml-r129/model/capabilities.prl +29 -0
  86. package/oiml-r129/model/characteristics.prl +8 -0
  87. package/oiml-r129/model/conditions.prl +23 -0
  88. package/oiml-r129/model/instrument.prl +67 -0
  89. package/oiml-r129/model/state.prl +22 -0
  90. package/oiml-r129/model/twin.prl +23 -0
  91. package/oiml-r129/package.primmel +15 -0
  92. package/oiml-r129/payload/application.yaml +40 -0
  93. package/oiml-r129/payload/conditions-common-test.yaml +8 -0
  94. package/oiml-r129/payload/formulas-variants.yaml +33 -0
  95. package/oiml-r129/payload/promises.yaml +102 -0
  96. package/oiml-r129/payload/sample-data.yaml +300 -0
  97. package/oiml-r129/references.prl +306 -0
  98. package/oiml-r129/sources-prd/coverage.json +59 -0
  99. package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
  100. package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
  101. package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
  102. package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
  103. package/oiml-r129/specification/calculations.prl +83 -0
  104. package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
  105. package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
  106. package/oiml-r129/specification/conformance/examinations.prl +83 -0
  107. package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
  108. package/oiml-r129/specification/formulas.prl +9 -0
  109. package/oiml-r129/specification/requirements/electronic.prl +46 -0
  110. package/oiml-r129/specification/requirements/metrological.prl +83 -0
  111. package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
  112. package/oiml-r129/specification/requirements/software.prl +57 -0
  113. package/oiml-r129/specification/requirements/technical.prl +134 -0
  114. package/oiml-r129/specification/symbols.prl +187 -0
  115. package/oiml-r129/specification/tables.prl +74 -0
  116. package/oiml-r129/terminology.prl +415 -0
  117. package/oiml-r129/value-types.prl +40 -0
  118. package/oiml-r144/.primmel-allowlist.prl +2 -0
  119. package/oiml-r144/entities/instrument.prl +360 -0
  120. package/oiml-r144/entities/test-execution.prl +228 -0
  121. package/oiml-r144/entities/workflow.prl +2075 -0
  122. package/oiml-r144/evaluation/processes.prl +152 -0
  123. package/oiml-r144/evaluation/workflow.prl +48 -0
  124. package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
  125. package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
  126. package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
  127. package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
  128. package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
  129. package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
  130. package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
  131. package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
  132. package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
  133. package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
  134. package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
  135. package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
  136. package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
  137. package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
  138. package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
  139. package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
  140. package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
  141. package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
  142. package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
  143. package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
  144. package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
  145. package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
  146. package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
  147. package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
  148. package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
  149. package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
  150. package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
  151. package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
  152. package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
  153. package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
  154. package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
  155. package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
  156. package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
  157. package/oiml-r144/execution/forms/shared/headers.prl +132 -0
  158. package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
  159. package/oiml-r144/layers.prl +44 -0
  160. package/oiml-r144/model/attributes.prl +679 -0
  161. package/oiml-r144/model/behaviors.prl +117 -0
  162. package/oiml-r144/model/capabilities.prl +99 -0
  163. package/oiml-r144/model/characteristics.prl +27 -0
  164. package/oiml-r144/model/conditions.prl +46 -0
  165. package/oiml-r144/model/instrument.prl +85 -0
  166. package/oiml-r144/model/state.prl +18 -0
  167. package/oiml-r144/model/twin.prl +25 -0
  168. package/oiml-r144/package.primmel +15 -0
  169. package/oiml-r144/payload/application.yaml +80 -0
  170. package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
  171. package/oiml-r144/payload/conditions-common-test.yaml +74 -0
  172. package/oiml-r144/payload/formulas-variants.yaml +32 -0
  173. package/oiml-r144/payload/promises.yaml +118 -0
  174. package/oiml-r144/payload/sample-data.yaml +643 -0
  175. package/oiml-r144/references.prl +594 -0
  176. package/oiml-r144/sources-prd/coverage.json +114 -0
  177. package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
  178. package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
  179. package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
  180. package/oiml-r144/specification/calculations.prl +123 -0
  181. package/oiml-r144/specification/conformance/examination.prl +87 -0
  182. package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
  183. package/oiml-r144/specification/formulas.prl +37 -0
  184. package/oiml-r144/specification/reference-materials.prl +87 -0
  185. package/oiml-r144/specification/requirements/controls.prl +51 -0
  186. package/oiml-r144/specification/requirements/metrological.prl +299 -0
  187. package/oiml-r144/specification/requirements/report.prl +35 -0
  188. package/oiml-r144/specification/requirements/technical.prl +455 -0
  189. package/oiml-r144/specification/symbols.prl +357 -0
  190. package/oiml-r144/specification/tables.prl +95 -0
  191. package/oiml-r144/specification/test-point-sets.prl +15 -0
  192. package/oiml-r144/terminology.prl +308 -0
  193. package/oiml-r144/value-types.prl +49 -0
  194. package/oiml-r60/.primmel-allowlist.prl +2 -0
  195. package/oiml-r60/entities/workflow.prl +2079 -0
  196. package/oiml-r60/evaluation/processes.prl +152 -0
  197. package/oiml-r60/evaluation/workflow.prl +48 -0
  198. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
  199. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
  200. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
  201. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
  202. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
  203. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
  204. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
  205. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
  206. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
  207. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
  208. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
  209. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
  210. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
  211. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
  212. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
  213. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
  214. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
  215. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
  216. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
  217. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
  218. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
  219. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
  220. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
  221. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
  222. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
  223. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
  224. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
  225. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
  226. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
  227. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
  228. package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
  229. package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
  230. package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
  231. package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
  232. package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
  233. package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
  234. package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
  235. package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
  236. package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
  237. package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
  238. package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
  239. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
  240. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
  241. package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
  242. package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
  243. package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
  244. package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
  245. package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
  246. package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
  247. package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
  248. package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
  249. package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
  250. package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
  251. package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
  252. package/oiml-r60/execution/forms/shared/headers.prl +255 -0
  253. package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
  254. package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
  255. package/oiml-r60/layers.prl +46 -0
  256. package/oiml-r60/model/attributes.prl +642 -0
  257. package/oiml-r60/model/behaviors.prl +165 -0
  258. package/oiml-r60/model/capabilities.prl +57 -0
  259. package/oiml-r60/model/characteristics.prl +27 -0
  260. package/oiml-r60/model/conditions.prl +50 -0
  261. package/oiml-r60/model/instrument.prl +96 -0
  262. package/oiml-r60/model/processes.prl +54 -0
  263. package/oiml-r60/model/state.prl +22 -0
  264. package/oiml-r60/model/twin.prl +16 -0
  265. package/oiml-r60/package.primmel +16 -0
  266. package/oiml-r60/payload/annexes-part4.yaml +122 -0
  267. package/oiml-r60/payload/application.yaml +83 -0
  268. package/oiml-r60/payload/conditions-common-test.yaml +121 -0
  269. package/oiml-r60/payload/formulas-variants.yaml +55 -0
  270. package/oiml-r60/payload/promises.yaml +224 -0
  271. package/oiml-r60/payload/sample-data.yaml +5025 -0
  272. package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
  273. package/oiml-r60/references.prl +549 -0
  274. package/oiml-r60/sources-prd/coverage.json +740 -0
  275. package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
  276. package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
  277. package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
  278. package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
  279. package/oiml-r60/specification/calculations.prl +318 -0
  280. package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
  281. package/oiml-r60/specification/conformance/electronic.prl +483 -0
  282. package/oiml-r60/specification/conformance/examination.prl +183 -0
  283. package/oiml-r60/specification/conformance/metrological.prl +478 -0
  284. package/oiml-r60/specification/constraints.prl +58 -0
  285. package/oiml-r60/specification/formulas-used.prl +43 -0
  286. package/oiml-r60/specification/formulas.prl +20 -0
  287. package/oiml-r60/specification/requirements/class-specific.prl +655 -0
  288. package/oiml-r60/specification/requirements/classification.prl +114 -0
  289. package/oiml-r60/specification/requirements/electronic.prl +222 -0
  290. package/oiml-r60/specification/requirements/metrological.prl +381 -0
  291. package/oiml-r60/specification/requirements/technical.prl +146 -0
  292. package/oiml-r60/specification/symbols.prl +599 -0
  293. package/oiml-r60/specification/tables.prl +182 -0
  294. package/oiml-r60/specification/test-sequences.prl +72 -0
  295. package/oiml-r60/terminology.prl +920 -0
  296. package/oiml-r60/value-types.prl +46 -0
  297. package/oiml-r91/.primmel-allowlist.prl +3 -0
  298. package/oiml-r91/entities/instrument.prl +359 -0
  299. package/oiml-r91/entities/workflow.prl +2075 -0
  300. package/oiml-r91/evaluation/processes.prl +152 -0
  301. package/oiml-r91/evaluation/workflow.prl +48 -0
  302. package/oiml-r91/execution/forms/evidence-file.prl +41 -0
  303. package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
  304. package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
  305. package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
  306. package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
  307. package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
  308. package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
  309. package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
  310. package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
  311. package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
  312. package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
  313. package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
  314. package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
  315. package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
  316. package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
  317. package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
  318. package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
  319. package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
  320. package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
  321. package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
  322. package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
  323. package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
  324. package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
  325. package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
  326. package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
  327. package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
  328. package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
  329. package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
  330. package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
  331. package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
  332. package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
  333. package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
  334. package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
  335. package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
  336. package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
  337. package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
  338. package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
  339. package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
  340. package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
  341. package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
  342. package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
  343. package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
  344. package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
  345. package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
  346. package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
  347. package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
  348. package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
  349. package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
  350. package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
  351. package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
  352. package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
  353. package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
  354. package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
  355. package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
  356. package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
  357. package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
  358. package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
  359. package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
  360. package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
  361. package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
  362. package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
  363. package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
  364. package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
  365. package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
  366. package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
  367. package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
  368. package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
  369. package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
  370. package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
  371. package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
  372. package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
  373. package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
  374. package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
  375. package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
  376. package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
  377. package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
  378. package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
  379. package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
  380. package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
  381. package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
  382. package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
  383. package/oiml-r91/layers.prl +46 -0
  384. package/oiml-r91/model/artifacts.prl +29 -0
  385. package/oiml-r91/model/attributes.prl +698 -0
  386. package/oiml-r91/model/behaviors.prl +142 -0
  387. package/oiml-r91/model/capabilities.prl +88 -0
  388. package/oiml-r91/model/characteristics.prl +27 -0
  389. package/oiml-r91/model/conditions.prl +37 -0
  390. package/oiml-r91/model/instrument.prl +147 -0
  391. package/oiml-r91/model/state.prl +22 -0
  392. package/oiml-r91/model/twin.prl +17 -0
  393. package/oiml-r91/package.primmel +14 -0
  394. package/oiml-r91/payload/application.yaml +201 -0
  395. package/oiml-r91/payload/conditions-common-test.yaml +19 -0
  396. package/oiml-r91/payload/promises.yaml +142 -0
  397. package/oiml-r91/payload/sample-data.yaml +464 -0
  398. package/oiml-r91/references.prl +72 -0
  399. package/oiml-r91/sources-prd/coverage.json +106 -0
  400. package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
  401. package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
  402. package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
  403. package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
  404. package/oiml-r91/specification/calculations.prl +26 -0
  405. package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
  406. package/oiml-r91/specification/conformance/metrological.prl +906 -0
  407. package/oiml-r91/specification/formulas.prl +10 -0
  408. package/oiml-r91/specification/requirements/class-specific.prl +308 -0
  409. package/oiml-r91/specification/requirements/metrological.prl +176 -0
  410. package/oiml-r91/specification/requirements/technical.prl +173 -0
  411. package/oiml-r91/specification/symbols.prl +323 -0
  412. package/oiml-r91/specification/tables.prl +136 -0
  413. package/oiml-r91/terminology.prl +535 -0
  414. package/oiml-r91/value-types.prl +26 -0
  415. package/oiml-smart-core/entities/comments.prl +101 -0
  416. package/oiml-smart-core/entities/cs-operations.prl +492 -0
  417. package/oiml-smart-core/entities/cs-participants.prl +470 -0
  418. package/oiml-smart-core/entities/engagement.prl +323 -0
  419. package/oiml-smart-core/entities/instrument.prl +359 -0
  420. package/oiml-smart-core/entities/module-b.prl +214 -0
  421. package/oiml-smart-core/entities/operated-schemes.prl +141 -0
  422. package/oiml-smart-core/entities/parties.prl +429 -0
  423. package/oiml-smart-core/entities/payment-records.prl +92 -0
  424. package/oiml-smart-core/entities/verification.prl +187 -0
  425. package/oiml-smart-core/entities/workflow.prl +2075 -0
  426. package/oiml-smart-core/evaluation/roles.prl +65 -0
  427. package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
  428. package/oiml-smart-core/package.primmel +10 -0
  429. package/oiml-smart-core/specification/competence-kinds.prl +64 -0
  430. package/oiml-smart-core/specification/constraints.prl +40 -0
  431. package/oiml-smart-core/specification/invariants.prl +90 -0
  432. package/oiml-smart-core/specification/predicates.prl +116 -0
  433. package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
  434. package/oiml-smart-module-env-iec60068/package.primmel +10 -0
  435. package/oiml-smart-module-examination-docs/package.primmel +10 -0
  436. package/oiml-smart-module-reference-materials/package.primmel +10 -0
  437. package/oiml-smart-module-report-headers/package.primmel +10 -0
  438. package/oiml-smart-module-software-d31/package.primmel +10 -0
  439. package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
  440. package/oiml-smart-module-specimen-governance/package.primmel +10 -0
  441. package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
  442. package/oiml-twin-cert/evaluation/roles.prl +15 -0
  443. package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
  444. package/oiml-twin-cert/execution/forms/probe.prl +99 -0
  445. package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
  446. package/oiml-twin-cert/model/attributes.prl +243 -0
  447. package/oiml-twin-cert/model/behaviors.prl +8 -0
  448. package/oiml-twin-cert/model/characteristics.prl +18 -0
  449. package/oiml-twin-cert/model/monitors.prl +16 -0
  450. package/oiml-twin-cert/package.primmel +16 -0
  451. package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
  452. package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
  453. package/oiml-twin-cert/specification/symbols.prl +36 -0
  454. package/oiml-twin-cert/terminology.prl +8 -0
  455. package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
  456. package/package.json +17 -0
  457. package/qms-ref/model/qms.prl +31 -0
  458. package/qms-ref/package.primmel +38 -0
  459. package/quarry-belt-scale/model/ops.prl +115 -0
  460. package/quarry-belt-scale/package.primmel +36 -0
@@ -0,0 +1,46 @@
1
+ form r91-3/report-3-18 {
2
+ name "3.18 VLF and LF disturbances on AC and DC mains"
3
+ description "R 91-3 test report, section 3.18 — the vlf and lf disturbances on ac and dc mains record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/vlf-lf-disturbances-ac-mains
7
+ section "R 91-3, p. 44"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-18-vlf-and-lf-disturbances-on-ac-and-dc-mains"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-18-vlf-and-lf-disturbances-on-ac-and-dc-mains/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-18-vlf-and-lf-disturbances-on-ac-and-dc-mains/table-2"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-16"
13
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
14
+ field measurements : array {
15
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
16
+ required true
17
+ subform_ref speed-measurement-row { }
18
+ }
19
+ field no_significant_fault : boolean {
20
+ label "No significant fault (NSFd)"
21
+ description "No significant fault occurred during the disturbance"
22
+ required true
23
+ measurement_method evaluated
24
+ targets { /req/metrological/disturbances }
25
+ true_label "Pass"
26
+ false_label "Fail"
27
+ }
28
+ field eut_operates_after : boolean {
29
+ label "EUT operates as intended after the test without manual intervention"
30
+ required true
31
+ measurement_method evaluated
32
+ targets { /req/metrological/disturbances }
33
+ true_label "Pass"
34
+ false_label "Fail"
35
+ }
36
+ field d11_reference : string {
37
+ label "Reference to OIML D 11:2013"
38
+ description "D 11 test-method reference recorded on the report form (clause 25)"
39
+ default "clause 25"
40
+ }
41
+ field remarks : text {
42
+
43
+ }
44
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
45
+ }
46
+
@@ -0,0 +1,44 @@
1
+ form r91-3/report-3-19 {
2
+ name "3.19 Bursts (transients) on AC and DC mains"
3
+ description "R 91-3 test report, section 3.19 — the bursts (transients) on ac and dc mains record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/bursts-ac-dc-mains
7
+ section "R 91-3, p. 45"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-19-bursts-transients-on-ac-and-dc-mains"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-19-bursts-transients-on-ac-and-dc-mains/table-1"
11
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
12
+ field measurements : array {
13
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
14
+ required true
15
+ subform_ref speed-measurement-row { }
16
+ }
17
+ field no_significant_fault : boolean {
18
+ label "No significant fault (NSFd)"
19
+ description "No significant fault occurred during the disturbance"
20
+ required true
21
+ measurement_method evaluated
22
+ targets { /req/metrological/disturbances }
23
+ true_label "Pass"
24
+ false_label "Fail"
25
+ }
26
+ field eut_operates_after : boolean {
27
+ label "EUT operates as intended after the test without manual intervention"
28
+ required true
29
+ measurement_method evaluated
30
+ targets { /req/metrological/disturbances }
31
+ true_label "Pass"
32
+ false_label "Fail"
33
+ }
34
+ field d11_reference : string {
35
+ label "Reference to OIML D 11:2013"
36
+ description "D 11 test-method reference recorded on the report form (clause 26)"
37
+ default "clause 26"
38
+ }
39
+ field remarks : text {
40
+
41
+ }
42
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
43
+ }
44
+
@@ -0,0 +1,45 @@
1
+ form r91-3/report-3-20 {
2
+ name "3.20 Surges on AC and DC mains power lines"
3
+ description "R 91-3 test report, section 3.20 — the surges on ac and dc mains power lines record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/surges-ac-dc-mains
7
+ section "R 91-3, p. 46"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-20-surges-on-ac-and-dc-mains-power-lines"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-20-surges-on-ac-and-dc-mains-power-lines/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-20-surges-on-ac-and-dc-mains-power-lines/table-2"
12
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
13
+ field measurements : array {
14
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
15
+ required true
16
+ subform_ref speed-measurement-row { }
17
+ }
18
+ field no_significant_fault : boolean {
19
+ label "No significant fault (NSFd)"
20
+ description "No significant fault occurred during the disturbance"
21
+ required true
22
+ measurement_method evaluated
23
+ targets { /req/metrological/disturbances }
24
+ true_label "Pass"
25
+ false_label "Fail"
26
+ }
27
+ field eut_operates_after : boolean {
28
+ label "EUT operates as intended after the test without manual intervention"
29
+ required true
30
+ measurement_method evaluated
31
+ targets { /req/metrological/disturbances }
32
+ true_label "Pass"
33
+ false_label "Fail"
34
+ }
35
+ field d11_reference : string {
36
+ label "Reference to OIML D 11:2013"
37
+ description "D 11 test-method reference recorded on the report form (clause 27)"
38
+ default "clause 27"
39
+ }
40
+ field remarks : text {
41
+
42
+ }
43
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
44
+ }
45
+
@@ -0,0 +1,45 @@
1
+ form r91-3/report-3-21 {
2
+ name "3.21 Bursts (transients) on signal, data and control lines"
3
+ description "R 91-3 test report, section 3.21 — the bursts (transients) on signal, data and control lines record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/bursts-signal-lines
7
+ section "R 91-3, p. 47"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-21-bursts-transients-on-signal-data-and-control-lines"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-21-bursts-transients-on-signal-data-and-control-lines/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-21-bursts-transients-on-signal-data-and-control-lines/table-2"
12
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
13
+ field measurements : array {
14
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
15
+ required true
16
+ subform_ref speed-measurement-row { }
17
+ }
18
+ field no_significant_fault : boolean {
19
+ label "No significant fault (NSFd)"
20
+ description "No significant fault occurred during the disturbance"
21
+ required true
22
+ measurement_method evaluated
23
+ targets { /req/metrological/disturbances }
24
+ true_label "Pass"
25
+ false_label "Fail"
26
+ }
27
+ field eut_operates_after : boolean {
28
+ label "EUT operates as intended after the test without manual intervention"
29
+ required true
30
+ measurement_method evaluated
31
+ targets { /req/metrological/disturbances }
32
+ true_label "Pass"
33
+ false_label "Fail"
34
+ }
35
+ field d11_reference : string {
36
+ label "Reference to OIML D 11:2013"
37
+ description "D 11 test-method reference recorded on the report form (clause 28)"
38
+ default "clause 28"
39
+ }
40
+ field remarks : text {
41
+
42
+ }
43
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
44
+ }
45
+
@@ -0,0 +1,46 @@
1
+ form r91-3/report-3-22 {
2
+ name "3.22 Surges on signal, data and control lines"
3
+ description "R 91-3 test report, section 3.22 — the surges on signal, data and control lines record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/surges-signal-lines
7
+ section "R 91-3, p. 48"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-22-surges-on-signal-data-and-control-lines"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-22-surges-on-signal-data-and-control-lines/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-17"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-17/table-1"
13
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
14
+ field measurements : array {
15
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
16
+ required true
17
+ subform_ref speed-measurement-row { }
18
+ }
19
+ field no_significant_fault : boolean {
20
+ label "No significant fault (NSFd)"
21
+ description "No significant fault occurred during the disturbance"
22
+ required true
23
+ measurement_method evaluated
24
+ targets { /req/metrological/disturbances }
25
+ true_label "Pass"
26
+ false_label "Fail"
27
+ }
28
+ field eut_operates_after : boolean {
29
+ label "EUT operates as intended after the test without manual intervention"
30
+ required true
31
+ measurement_method evaluated
32
+ targets { /req/metrological/disturbances }
33
+ true_label "Pass"
34
+ false_label "Fail"
35
+ }
36
+ field d11_reference : string {
37
+ label "Reference to OIML D 11:2013"
38
+ description "D 11 test-method reference recorded on the report form (clause 29)"
39
+ default "clause 29"
40
+ }
41
+ field remarks : text {
42
+
43
+ }
44
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
45
+ }
46
+
@@ -0,0 +1,45 @@
1
+ form r91-3/report-3-23 {
2
+ name "3.23 AC mains power frequency magnetic field"
3
+ description "R 91-3 test report, section 3.23 — the ac mains power frequency magnetic field record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/ac-mains-power-frequency-magnetic-field
7
+ section "R 91-3, p. 49"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-23-ac-mains-power-frequency-magnetic-field"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-23-ac-mains-power-frequency-magnetic-field/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-23-ac-mains-power-frequency-magnetic-field/table-2"
12
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
13
+ field measurements : array {
14
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
15
+ required true
16
+ subform_ref speed-measurement-row { }
17
+ }
18
+ field no_significant_fault : boolean {
19
+ label "No significant fault (NSFd)"
20
+ description "No significant fault occurred during the disturbance"
21
+ required true
22
+ measurement_method evaluated
23
+ targets { /req/metrological/disturbances }
24
+ true_label "Pass"
25
+ false_label "Fail"
26
+ }
27
+ field eut_operates_after : boolean {
28
+ label "EUT operates as intended after the test without manual intervention"
29
+ required true
30
+ measurement_method evaluated
31
+ targets { /req/metrological/disturbances }
32
+ true_label "Pass"
33
+ false_label "Fail"
34
+ }
35
+ field d11_reference : string {
36
+ label "Reference to OIML D 11:2013"
37
+ description "D 11 test-method reference recorded on the report form (clause 30)"
38
+ default "clause 30"
39
+ }
40
+ field remarks : text {
41
+
42
+ }
43
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
44
+ }
45
+
@@ -0,0 +1,46 @@
1
+ form r91-3/report-3-24 {
2
+ name "3.24 Conducted (common mode) currents generated by RF electromagnetic fields"
3
+ description "R 91-3 test report, section 3.24 — the conducted (common mode) currents generated by rf electromagnetic fields record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/conducted-rf-common-mode-currents
7
+ section "R 91-3, p. 50"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-24-conducted-common-mode-currents-generated-by-rf-electromagnetic-fields"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-24-conducted-common-mode-currents-generated-by-rf-electromagnetic-fields/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-24-conducted-common-mode-currents-generated-by-rf-electromagnetic-fields/table-2"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-17"
13
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
14
+ field measurements : array {
15
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
16
+ required true
17
+ subform_ref speed-measurement-row { }
18
+ }
19
+ field no_significant_fault : boolean {
20
+ label "No significant fault (NSFd)"
21
+ description "No significant fault occurred during the disturbance"
22
+ required true
23
+ measurement_method evaluated
24
+ targets { /req/metrological/disturbances }
25
+ true_label "Pass"
26
+ false_label "Fail"
27
+ }
28
+ field eut_operates_after : boolean {
29
+ label "EUT operates as intended after the test without manual intervention"
30
+ required true
31
+ measurement_method evaluated
32
+ targets { /req/metrological/disturbances }
33
+ true_label "Pass"
34
+ false_label "Fail"
35
+ }
36
+ field d11_reference : string {
37
+ label "Reference to OIML D 11:2013"
38
+ description "D 11 test-method reference recorded on the report form (clause 31)"
39
+ default "clause 31"
40
+ }
41
+ field remarks : text {
42
+
43
+ }
44
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
45
+ }
46
+
@@ -0,0 +1,49 @@
1
+ form r91-3/report-3-25 {
2
+ name "3.25 RF electromagnetic fields"
3
+ description "R 91-3 test report, section 3.25 — the rf electromagnetic fields record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/rf-electromagnetic-fields
7
+ section "R 91-3, p. 51"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-25-rf-electromagnetic-fields"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-25-rf-electromagnetic-fields/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-18"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-14"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-14/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-14/table-2"
15
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-14/table-3"
16
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
17
+ field measurements : array {
18
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
19
+ required true
20
+ subform_ref speed-measurement-row { }
21
+ }
22
+ field no_significant_fault : boolean {
23
+ label "No significant fault (NSFd)"
24
+ description "No significant fault occurred during the disturbance"
25
+ required true
26
+ measurement_method evaluated
27
+ targets { /req/metrological/disturbances }
28
+ true_label "Pass"
29
+ false_label "Fail"
30
+ }
31
+ field eut_operates_after : boolean {
32
+ label "EUT operates as intended after the test without manual intervention"
33
+ required true
34
+ measurement_method evaluated
35
+ targets { /req/metrological/disturbances }
36
+ true_label "Pass"
37
+ false_label "Fail"
38
+ }
39
+ field d11_reference : string {
40
+ label "Reference to OIML D 11:2013"
41
+ description "D 11 test-method reference recorded on the report form (clause 32)"
42
+ default "clause 32"
43
+ }
44
+ field remarks : text {
45
+
46
+ }
47
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
48
+ }
49
+
@@ -0,0 +1,47 @@
1
+ form r91-3/report-3-26 {
2
+ name "3.26 Electrostatic discharges"
3
+ description "R 91-3 test report, section 3.26 — the electrostatic discharges record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/electrostatic-discharges
7
+ section "R 91-3, p. 52"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-26-electrostatic-discharges"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-26-electrostatic-discharges/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-19"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-19/table-1"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-18"
14
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
15
+ field measurements : array {
16
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
17
+ required true
18
+ subform_ref speed-measurement-row { }
19
+ }
20
+ field no_significant_fault : boolean {
21
+ label "No significant fault (NSFd)"
22
+ description "No significant fault occurred during the disturbance"
23
+ required true
24
+ measurement_method evaluated
25
+ targets { /req/metrological/disturbances }
26
+ true_label "Pass"
27
+ false_label "Fail"
28
+ }
29
+ field eut_operates_after : boolean {
30
+ label "EUT operates as intended after the test without manual intervention"
31
+ required true
32
+ measurement_method evaluated
33
+ targets { /req/metrological/disturbances }
34
+ true_label "Pass"
35
+ false_label "Fail"
36
+ }
37
+ field d11_reference : string {
38
+ label "Reference to OIML D 11:2013"
39
+ description "D 11 test-method reference recorded on the report form (clause 35)"
40
+ default "clause 35"
41
+ }
42
+ field remarks : text {
43
+
44
+ }
45
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
46
+ }
47
+
@@ -0,0 +1,40 @@
1
+ form r91-3/report-3-27 {
2
+ name "3.27 Low voltage of internal battery"
3
+ description "R 91-3 test report, section 3.27 — the low voltage of internal battery record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/influence/internal-battery-low-voltage
7
+ section "R 91-3, p. 53"
8
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-27-low-voltage-of-internal-battery"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-27-low-voltage-of-internal-battery/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-20"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-15"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-15/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-19"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field evidence_files_intact : boolean {
22
+ label "Evidence files intact"
23
+ description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/linearity-limit }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field d11_reference : string {
31
+ label "Reference to OIML D 11:2013"
32
+ description "D 11 test-method reference recorded on the report form (clause 36)"
33
+ default "clause 36"
34
+ }
35
+ field remarks : text {
36
+
37
+ }
38
+ pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
39
+ }
40
+
@@ -0,0 +1,40 @@
1
+ form r91-3/report-3-28 {
2
+ name "3.28 Voltage variations of a road vehicle battery"
3
+ description "R 91-3 test report, section 3.28 — the voltage variations of a road vehicle battery record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/influence/road-vehicle-battery-voltage-variations
7
+ section "R 91-3, p. 54"
8
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-28-voltage-variations-of-a-road-vehicle-battery"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-28-voltage-variations-of-a-road-vehicle-battery/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-21"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-16"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-16/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-20"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field evidence_files_intact : boolean {
22
+ label "Evidence files intact"
23
+ description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/linearity-limit }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field d11_reference : string {
31
+ label "Reference to OIML D 11:2013"
32
+ description "D 11 test-method reference recorded on the report form (clause 37)"
33
+ default "clause 37"
34
+ }
35
+ field remarks : text {
36
+
37
+ }
38
+ pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
39
+ }
40
+
@@ -0,0 +1,47 @@
1
+ form r91-3/report-3-29 {
2
+ name "3.29 Electrical transient conduction along supply lines of external 12 V and 24 V batteries"
3
+ description "R 91-3 test report, section 3.29 — the electrical transient conduction along supply lines of external 12 v and 24 v batteries record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/transient-conduction-supply-lines
7
+ section "R 91-3, p. 55"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-29-electrical-transient-conduction-along-supply-lines-of-external-12-v-and-24-v-batteries"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-29-electrical-transient-conduction-along-supply-lines-of-external-12-v-and-24-v-batteries/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-17"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-17/table-1"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-21"
14
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
15
+ field measurements : array {
16
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
17
+ required true
18
+ subform_ref speed-measurement-row { }
19
+ }
20
+ field no_significant_fault : boolean {
21
+ label "No significant fault (NSFd)"
22
+ description "No significant fault occurred during the disturbance"
23
+ required true
24
+ measurement_method evaluated
25
+ targets { /req/metrological/disturbances }
26
+ true_label "Pass"
27
+ false_label "Fail"
28
+ }
29
+ field eut_operates_after : boolean {
30
+ label "EUT operates as intended after the test without manual intervention"
31
+ required true
32
+ measurement_method evaluated
33
+ targets { /req/metrological/disturbances }
34
+ true_label "Pass"
35
+ false_label "Fail"
36
+ }
37
+ field d11_reference : string {
38
+ label "Reference to OIML D 11:2013"
39
+ description "D 11 test-method reference recorded on the report form (clause 38)"
40
+ default "clause 38"
41
+ }
42
+ field remarks : text {
43
+
44
+ }
45
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
46
+ }
47
+
@@ -0,0 +1,45 @@
1
+ form r91-3/report-3-30 {
2
+ name "3.30 Electrical transient conduction via lines other than supply lines for external 12 V and 24 V batteries"
3
+ description "R 91-3 test report, section 3.30 — the electrical transient conduction via lines other than supply lines for external 12 v and 24 v batteries record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/transient-conduction-other-lines
7
+ section "R 91-3, p. 56"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-30-electrical-transient-conduction-via-lines-other-than-supply-lines-for-external-12-v-and-24-v-batteries"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-30-electrical-transient-conduction-via-lines-other-than-supply-lines-for-external-12-v-and-24-v-batteries/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-30-electrical-transient-conduction-via-lines-other-than-supply-lines-for-external-12-v-and-24-v-batteries/table-2"
12
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
13
+ field measurements : array {
14
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
15
+ required true
16
+ subform_ref speed-measurement-row { }
17
+ }
18
+ field no_significant_fault : boolean {
19
+ label "No significant fault (NSFd)"
20
+ description "No significant fault occurred during the disturbance"
21
+ required true
22
+ measurement_method evaluated
23
+ targets { /req/metrological/disturbances }
24
+ true_label "Pass"
25
+ false_label "Fail"
26
+ }
27
+ field eut_operates_after : boolean {
28
+ label "EUT operates as intended after the test without manual intervention"
29
+ required true
30
+ measurement_method evaluated
31
+ targets { /req/metrological/disturbances }
32
+ true_label "Pass"
33
+ false_label "Fail"
34
+ }
35
+ field d11_reference : string {
36
+ label "Reference to OIML D 11:2013"
37
+ description "D 11 test-method reference recorded on the report form (clause 39)"
38
+ default "clause 39"
39
+ }
40
+ field remarks : text {
41
+
42
+ }
43
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
44
+ }
45
+
@@ -0,0 +1,45 @@
1
+ form r91-3/report-3-31 {
2
+ name "3.31 Battery voltage variations during cranking"
3
+ description "R 91-3 test report, section 3.31 — the battery voltage variations during cranking record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/battery-voltage-cranking
7
+ section "R 91-3, p. 57"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-31-battery-voltage-variations-during-cranking"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-31-battery-voltage-variations-during-cranking/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-31-battery-voltage-variations-during-cranking/table-2"
12
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
13
+ field measurements : array {
14
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
15
+ required true
16
+ subform_ref speed-measurement-row { }
17
+ }
18
+ field no_significant_fault : boolean {
19
+ label "No significant fault (NSFd)"
20
+ description "No significant fault occurred during the disturbance"
21
+ required true
22
+ measurement_method evaluated
23
+ targets { /req/metrological/disturbances }
24
+ true_label "Pass"
25
+ false_label "Fail"
26
+ }
27
+ field eut_operates_after : boolean {
28
+ label "EUT operates as intended after the test without manual intervention"
29
+ required true
30
+ measurement_method evaluated
31
+ targets { /req/metrological/disturbances }
32
+ true_label "Pass"
33
+ false_label "Fail"
34
+ }
35
+ field d11_reference : string {
36
+ label "Reference to OIML D 11:2013"
37
+ description "D 11 test-method reference recorded on the report form (clause 40)"
38
+ default "clause 40"
39
+ }
40
+ field remarks : text {
41
+
42
+ }
43
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
44
+ }
45
+