@oimlsmart/primmel-packages 0.1.0
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/AGENTS.md +60 -0
- package/LICENSE +21 -0
- package/README.md +68 -0
- package/acme-cgm-200/model/cgm200.prl +284 -0
- package/acme-cgm-200/model/r144-map.prl +337 -0
- package/acme-cgm-200/package.primmel +39 -0
- package/acme-cgm-system/model/cgm-system.prl +125 -0
- package/acme-cgm-system/model/r144-map.prl +75 -0
- package/acme-cgm-system/model/sample-line.prl +42 -0
- package/acme-cgm-system/package.primmel +23 -0
- package/acme-lc500/model/lc500.prl +218 -0
- package/acme-lc500/model/passport.prl +43 -0
- package/acme-lc500/model/r60-map.prl +161 -0
- package/acme-lc500/model/twin-cert-map.prl +114 -0
- package/acme-lc500/package.primmel +35 -0
- package/acme-md3xx/model/md350.prl +317 -0
- package/acme-md3xx/model/r129-map.prl +346 -0
- package/acme-md3xx/package.primmel +49 -0
- package/acme-rs180/model/r91-map.prl +234 -0
- package/acme-rs180/model/rs180.prl +236 -0
- package/acme-rs180/package.primmel +47 -0
- package/ims-demo/model/ims.prl +23 -0
- package/ims-demo/model/isms-map.prl +60 -0
- package/ims-demo/model/qms-map.prl +73 -0
- package/ims-demo/package.primmel +42 -0
- package/isms-ref/model/isms.prl +34 -0
- package/isms-ref/package.primmel +35 -0
- package/iso-iec-17000/package.primmel +8 -0
- package/iso-iec-17000/terminology.prl +268 -0
- package/iso-iec-17025/package.primmel +10 -0
- package/iso-iec-17025/specification/requirements/lab.prl +474 -0
- package/iso-iec-17025/terminology.prl +72 -0
- package/iso-iec-17065/package.primmel +10 -0
- package/iso-iec-17065/specification/requirements/body.prl +446 -0
- package/iso-iec-17065/terminology.prl +103 -0
- package/iso-iec-17067/package.primmel +10 -0
- package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
- package/iso-iec-17067/terminology.prl +24 -0
- package/oiml-cs/package.primmel +10 -0
- package/oiml-cs/specification/discrepancies.prl +26 -0
- package/oiml-cs/specification/requirements/cs.prl +515 -0
- package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
- package/oiml-cs-dataspace/package.primmel +9 -0
- package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
- package/oiml-cs-dataspace/specification/policies.prl +68 -0
- package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
- package/oiml-integrated-ref/package.primmel +10 -0
- package/oiml-r129/.primmel-allowlist.prl +2 -0
- package/oiml-r129/evaluation/processes.prl +152 -0
- package/oiml-r129/evaluation/workflow.prl +48 -0
- package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
- package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
- package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
- package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
- package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
- package/oiml-r129/execution/forms/admin/identification.prl +49 -0
- package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
- package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
- package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
- package/oiml-r129/execution/forms/emc/esd.prl +66 -0
- package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
- package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
- package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
- package/oiml-r129/execution/forms/emc/surge.prl +61 -0
- package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
- package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
- package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
- package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
- package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
- package/oiml-r129/execution/forms/shared/headers.prl +86 -0
- package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
- package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
- package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
- package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
- package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
- package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
- package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
- package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
- package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
- package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
- package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
- package/oiml-r129/layers.prl +50 -0
- package/oiml-r129/model/attributes.prl +243 -0
- package/oiml-r129/model/behaviors.prl +79 -0
- package/oiml-r129/model/capabilities.prl +29 -0
- package/oiml-r129/model/characteristics.prl +8 -0
- package/oiml-r129/model/conditions.prl +23 -0
- package/oiml-r129/model/instrument.prl +67 -0
- package/oiml-r129/model/state.prl +22 -0
- package/oiml-r129/model/twin.prl +23 -0
- package/oiml-r129/package.primmel +15 -0
- package/oiml-r129/payload/application.yaml +40 -0
- package/oiml-r129/payload/conditions-common-test.yaml +8 -0
- package/oiml-r129/payload/formulas-variants.yaml +33 -0
- package/oiml-r129/payload/promises.yaml +102 -0
- package/oiml-r129/payload/sample-data.yaml +300 -0
- package/oiml-r129/references.prl +306 -0
- package/oiml-r129/sources-prd/coverage.json +59 -0
- package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
- package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
- package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
- package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
- package/oiml-r129/specification/calculations.prl +83 -0
- package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
- package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
- package/oiml-r129/specification/conformance/examinations.prl +83 -0
- package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
- package/oiml-r129/specification/formulas.prl +9 -0
- package/oiml-r129/specification/requirements/electronic.prl +46 -0
- package/oiml-r129/specification/requirements/metrological.prl +83 -0
- package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
- package/oiml-r129/specification/requirements/software.prl +57 -0
- package/oiml-r129/specification/requirements/technical.prl +134 -0
- package/oiml-r129/specification/symbols.prl +187 -0
- package/oiml-r129/specification/tables.prl +74 -0
- package/oiml-r129/terminology.prl +415 -0
- package/oiml-r129/value-types.prl +40 -0
- package/oiml-r144/.primmel-allowlist.prl +2 -0
- package/oiml-r144/entities/instrument.prl +360 -0
- package/oiml-r144/entities/test-execution.prl +228 -0
- package/oiml-r144/entities/workflow.prl +2075 -0
- package/oiml-r144/evaluation/processes.prl +152 -0
- package/oiml-r144/evaluation/workflow.prl +48 -0
- package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
- package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
- package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
- package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
- package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
- package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
- package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
- package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
- package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
- package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
- package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
- package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
- package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
- package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
- package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
- package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
- package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
- package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
- package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
- package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
- package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
- package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
- package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
- package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
- package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
- package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
- package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
- package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
- package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
- package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
- package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
- package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
- package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
- package/oiml-r144/execution/forms/shared/headers.prl +132 -0
- package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
- package/oiml-r144/layers.prl +44 -0
- package/oiml-r144/model/attributes.prl +679 -0
- package/oiml-r144/model/behaviors.prl +117 -0
- package/oiml-r144/model/capabilities.prl +99 -0
- package/oiml-r144/model/characteristics.prl +27 -0
- package/oiml-r144/model/conditions.prl +46 -0
- package/oiml-r144/model/instrument.prl +85 -0
- package/oiml-r144/model/state.prl +18 -0
- package/oiml-r144/model/twin.prl +25 -0
- package/oiml-r144/package.primmel +15 -0
- package/oiml-r144/payload/application.yaml +80 -0
- package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
- package/oiml-r144/payload/conditions-common-test.yaml +74 -0
- package/oiml-r144/payload/formulas-variants.yaml +32 -0
- package/oiml-r144/payload/promises.yaml +118 -0
- package/oiml-r144/payload/sample-data.yaml +643 -0
- package/oiml-r144/references.prl +594 -0
- package/oiml-r144/sources-prd/coverage.json +114 -0
- package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
- package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
- package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
- package/oiml-r144/specification/calculations.prl +123 -0
- package/oiml-r144/specification/conformance/examination.prl +87 -0
- package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
- package/oiml-r144/specification/formulas.prl +37 -0
- package/oiml-r144/specification/reference-materials.prl +87 -0
- package/oiml-r144/specification/requirements/controls.prl +51 -0
- package/oiml-r144/specification/requirements/metrological.prl +299 -0
- package/oiml-r144/specification/requirements/report.prl +35 -0
- package/oiml-r144/specification/requirements/technical.prl +455 -0
- package/oiml-r144/specification/symbols.prl +357 -0
- package/oiml-r144/specification/tables.prl +95 -0
- package/oiml-r144/specification/test-point-sets.prl +15 -0
- package/oiml-r144/terminology.prl +308 -0
- package/oiml-r144/value-types.prl +49 -0
- package/oiml-r60/.primmel-allowlist.prl +2 -0
- package/oiml-r60/entities/workflow.prl +2079 -0
- package/oiml-r60/evaluation/processes.prl +152 -0
- package/oiml-r60/evaluation/workflow.prl +48 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
- package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
- package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
- package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
- package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
- package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
- package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
- package/oiml-r60/execution/forms/shared/headers.prl +255 -0
- package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
- package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
- package/oiml-r60/layers.prl +46 -0
- package/oiml-r60/model/attributes.prl +642 -0
- package/oiml-r60/model/behaviors.prl +165 -0
- package/oiml-r60/model/capabilities.prl +57 -0
- package/oiml-r60/model/characteristics.prl +27 -0
- package/oiml-r60/model/conditions.prl +50 -0
- package/oiml-r60/model/instrument.prl +96 -0
- package/oiml-r60/model/processes.prl +54 -0
- package/oiml-r60/model/state.prl +22 -0
- package/oiml-r60/model/twin.prl +16 -0
- package/oiml-r60/package.primmel +16 -0
- package/oiml-r60/payload/annexes-part4.yaml +122 -0
- package/oiml-r60/payload/application.yaml +83 -0
- package/oiml-r60/payload/conditions-common-test.yaml +121 -0
- package/oiml-r60/payload/formulas-variants.yaml +55 -0
- package/oiml-r60/payload/promises.yaml +224 -0
- package/oiml-r60/payload/sample-data.yaml +5025 -0
- package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
- package/oiml-r60/references.prl +549 -0
- package/oiml-r60/sources-prd/coverage.json +740 -0
- package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
- package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
- package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
- package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
- package/oiml-r60/specification/calculations.prl +318 -0
- package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
- package/oiml-r60/specification/conformance/electronic.prl +483 -0
- package/oiml-r60/specification/conformance/examination.prl +183 -0
- package/oiml-r60/specification/conformance/metrological.prl +478 -0
- package/oiml-r60/specification/constraints.prl +58 -0
- package/oiml-r60/specification/formulas-used.prl +43 -0
- package/oiml-r60/specification/formulas.prl +20 -0
- package/oiml-r60/specification/requirements/class-specific.prl +655 -0
- package/oiml-r60/specification/requirements/classification.prl +114 -0
- package/oiml-r60/specification/requirements/electronic.prl +222 -0
- package/oiml-r60/specification/requirements/metrological.prl +381 -0
- package/oiml-r60/specification/requirements/technical.prl +146 -0
- package/oiml-r60/specification/symbols.prl +599 -0
- package/oiml-r60/specification/tables.prl +182 -0
- package/oiml-r60/specification/test-sequences.prl +72 -0
- package/oiml-r60/terminology.prl +920 -0
- package/oiml-r60/value-types.prl +46 -0
- package/oiml-r91/.primmel-allowlist.prl +3 -0
- package/oiml-r91/entities/instrument.prl +359 -0
- package/oiml-r91/entities/workflow.prl +2075 -0
- package/oiml-r91/evaluation/processes.prl +152 -0
- package/oiml-r91/evaluation/workflow.prl +48 -0
- package/oiml-r91/execution/forms/evidence-file.prl +41 -0
- package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
- package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
- package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
- package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
- package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
- package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
- package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
- package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
- package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
- package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
- package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
- package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
- package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
- package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
- package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
- package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
- package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
- package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
- package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
- package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
- package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
- package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
- package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
- package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
- package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
- package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
- package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
- package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
- package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
- package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
- package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
- package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
- package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
- package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
- package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
- package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
- package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
- package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
- package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
- package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
- package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
- package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
- package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
- package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
- package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
- package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
- package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
- package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
- package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
- package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
- package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
- package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
- package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
- package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
- package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
- package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
- package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
- package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
- package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
- package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
- package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
- package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
- package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
- package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
- package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
- package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
- package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
- package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
- package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
- package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
- package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
- package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
- package/oiml-r91/layers.prl +46 -0
- package/oiml-r91/model/artifacts.prl +29 -0
- package/oiml-r91/model/attributes.prl +698 -0
- package/oiml-r91/model/behaviors.prl +142 -0
- package/oiml-r91/model/capabilities.prl +88 -0
- package/oiml-r91/model/characteristics.prl +27 -0
- package/oiml-r91/model/conditions.prl +37 -0
- package/oiml-r91/model/instrument.prl +147 -0
- package/oiml-r91/model/state.prl +22 -0
- package/oiml-r91/model/twin.prl +17 -0
- package/oiml-r91/package.primmel +14 -0
- package/oiml-r91/payload/application.yaml +201 -0
- package/oiml-r91/payload/conditions-common-test.yaml +19 -0
- package/oiml-r91/payload/promises.yaml +142 -0
- package/oiml-r91/payload/sample-data.yaml +464 -0
- package/oiml-r91/references.prl +72 -0
- package/oiml-r91/sources-prd/coverage.json +106 -0
- package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
- package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
- package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
- package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
- package/oiml-r91/specification/calculations.prl +26 -0
- package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
- package/oiml-r91/specification/conformance/metrological.prl +906 -0
- package/oiml-r91/specification/formulas.prl +10 -0
- package/oiml-r91/specification/requirements/class-specific.prl +308 -0
- package/oiml-r91/specification/requirements/metrological.prl +176 -0
- package/oiml-r91/specification/requirements/technical.prl +173 -0
- package/oiml-r91/specification/symbols.prl +323 -0
- package/oiml-r91/specification/tables.prl +136 -0
- package/oiml-r91/terminology.prl +535 -0
- package/oiml-r91/value-types.prl +26 -0
- package/oiml-smart-core/entities/comments.prl +101 -0
- package/oiml-smart-core/entities/cs-operations.prl +492 -0
- package/oiml-smart-core/entities/cs-participants.prl +470 -0
- package/oiml-smart-core/entities/engagement.prl +323 -0
- package/oiml-smart-core/entities/instrument.prl +359 -0
- package/oiml-smart-core/entities/module-b.prl +214 -0
- package/oiml-smart-core/entities/operated-schemes.prl +141 -0
- package/oiml-smart-core/entities/parties.prl +429 -0
- package/oiml-smart-core/entities/payment-records.prl +92 -0
- package/oiml-smart-core/entities/verification.prl +187 -0
- package/oiml-smart-core/entities/workflow.prl +2075 -0
- package/oiml-smart-core/evaluation/roles.prl +65 -0
- package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
- package/oiml-smart-core/package.primmel +10 -0
- package/oiml-smart-core/specification/competence-kinds.prl +64 -0
- package/oiml-smart-core/specification/constraints.prl +40 -0
- package/oiml-smart-core/specification/invariants.prl +90 -0
- package/oiml-smart-core/specification/predicates.prl +116 -0
- package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
- package/oiml-smart-module-env-iec60068/package.primmel +10 -0
- package/oiml-smart-module-examination-docs/package.primmel +10 -0
- package/oiml-smart-module-reference-materials/package.primmel +10 -0
- package/oiml-smart-module-report-headers/package.primmel +10 -0
- package/oiml-smart-module-software-d31/package.primmel +10 -0
- package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
- package/oiml-smart-module-specimen-governance/package.primmel +10 -0
- package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
- package/oiml-twin-cert/evaluation/roles.prl +15 -0
- package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
- package/oiml-twin-cert/execution/forms/probe.prl +99 -0
- package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
- package/oiml-twin-cert/model/attributes.prl +243 -0
- package/oiml-twin-cert/model/behaviors.prl +8 -0
- package/oiml-twin-cert/model/characteristics.prl +18 -0
- package/oiml-twin-cert/model/monitors.prl +16 -0
- package/oiml-twin-cert/package.primmel +16 -0
- package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
- package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
- package/oiml-twin-cert/specification/symbols.prl +36 -0
- package/oiml-twin-cert/terminology.prl +8 -0
- package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
- package/package.json +17 -0
- package/qms-ref/model/qms.prl +31 -0
- package/qms-ref/package.primmel +38 -0
- package/quarry-belt-scale/model/ops.prl +115 -0
- package/quarry-belt-scale/package.primmel +36 -0
|
@@ -0,0 +1,35 @@
|
|
|
1
|
+
form r91-3/report-summary-tests {
|
|
2
|
+
name "Summary of type evaluation tests"
|
|
3
|
+
description "R 91-3 test report, section 16 — the summary of type evaluation tests: one conclusion row per OIML R 91-2 requirement (4 Metrological field test … 8.3.5 Maintenance and re-configuration) with the report page and the passed/failed record. The row vocabulary is the report's conclusion-row space for the laboratory/field/category/software tests (r144 F15): every executed conformance test of those families maps its verdict to its row(s)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
section "R 91-3, p. 17"
|
|
6
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-adjustments-or-modifications/table-1"
|
|
7
|
+
report_rows { field summary_rows item_key row }
|
|
8
|
+
field summary_rows : array {
|
|
9
|
+
label "Summary of type evaluation tests"
|
|
10
|
+
description "One row per OIML R 91-2 requirement"
|
|
11
|
+
required true
|
|
12
|
+
items { object fields {
|
|
13
|
+
field row : enum {
|
|
14
|
+
label "Requirement (OIML R 91-2)"
|
|
15
|
+
required true
|
|
16
|
+
enum_values { metrological-field-test maximum-permissible-error statistical-analysis-of-errors assignment-to-image-evidence laboratory-tests-traffic-simulation dynamic-performance-test speed-linearity-test distance-linearity-test angle-linearity-test influence-disturbance-tests evaluation-method-detailed-checklist acceleration-test further-influence-quantity-tests installation-alignment category-tests doppler-radar range-finding average-speed fixed-distance image-based across-the-road moving-speed-meters moving-field-test ego-field-test moving-traffic-simulation software-examination software-general-requirements software-protection software-hardware-support software-separation-interfaces software-maintenance-reconfiguration }
|
|
17
|
+
}
|
|
18
|
+
field report_page : string {
|
|
19
|
+
label "Report page"
|
|
20
|
+
}
|
|
21
|
+
field passed : boolean {
|
|
22
|
+
label "Passed"
|
|
23
|
+
measurement_method evaluated
|
|
24
|
+
}
|
|
25
|
+
field failed : boolean {
|
|
26
|
+
label "Failed"
|
|
27
|
+
measurement_method evaluated
|
|
28
|
+
}
|
|
29
|
+
field remarks : text {
|
|
30
|
+
|
|
31
|
+
}
|
|
32
|
+
} }
|
|
33
|
+
}
|
|
34
|
+
}
|
|
35
|
+
|
|
@@ -0,0 +1,36 @@
|
|
|
1
|
+
form r91-3/report-test-equipment {
|
|
2
|
+
name "Information concerning the test equipment used for type evaluation"
|
|
3
|
+
description "R 91-3 test report, section 14 — the test-equipment record. Per R 91-3, Introduction, the 'information concerning the test equipment used for type evaluation' shall cover all test equipment which has been used in determining the test results given in a report; the information may be a short list containing essential data (name, type, reference number for purpose of traceability)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
section "R 91-3, p. 14"
|
|
6
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-introduction"
|
|
7
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-information-concerning-the-test-equipment-used-for-type-evaluation"
|
|
8
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-information-concerning-the-test-equipment-used-for-type-evaluation/table-1"
|
|
9
|
+
field test_equipment : array {
|
|
10
|
+
label "Test equipment used in this report"
|
|
11
|
+
description "All test equipment used in determining the test results given in the report (including descriptions of the equipment used for testing) — essential data: name, type, reference number for purpose of traceability"
|
|
12
|
+
required true
|
|
13
|
+
items { object fields {
|
|
14
|
+
field equipment_name : string {
|
|
15
|
+
label "Equipment name"
|
|
16
|
+
required true
|
|
17
|
+
}
|
|
18
|
+
field manufacturer : string {
|
|
19
|
+
label "Manufacturer"
|
|
20
|
+
}
|
|
21
|
+
field equipment_type : string {
|
|
22
|
+
label "Type"
|
|
23
|
+
required true
|
|
24
|
+
}
|
|
25
|
+
field serial_no : string {
|
|
26
|
+
label "Serial no. (traceability reference)"
|
|
27
|
+
required true
|
|
28
|
+
}
|
|
29
|
+
field used_for : string {
|
|
30
|
+
label "Used for (test references)"
|
|
31
|
+
required true
|
|
32
|
+
}
|
|
33
|
+
} }
|
|
34
|
+
}
|
|
35
|
+
}
|
|
36
|
+
|
|
@@ -0,0 +1,16 @@
|
|
|
1
|
+
form r91-3/report-test-interface {
|
|
2
|
+
name "Test interface"
|
|
3
|
+
description "R 91-3 test report, section 11 — the test-interface description (access, parameters), recorded for the indication/modes/test-interface examination (R 91-1, 7.9)"
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
section "R 91-3, p. 13"
|
|
6
|
+
requirements { /req/technical/test-interface }
|
|
7
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-test-interface"
|
|
8
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-7.9"
|
|
9
|
+
field test_interface : text {
|
|
10
|
+
label "Test interface"
|
|
11
|
+
description "Describe, using point form, test interface (access, parameters)"
|
|
12
|
+
required true
|
|
13
|
+
targets { /req/technical/test-interface }
|
|
14
|
+
}
|
|
15
|
+
}
|
|
16
|
+
|
|
@@ -0,0 +1,84 @@
|
|
|
1
|
+
form r91-3/report-1-1 {
|
|
2
|
+
name "1.1 Traffic condition during measurement (metrological field test)"
|
|
3
|
+
description "R 91-3 test report, section 1.1 — the stationary metrological field test record (procedure per OIML R 91-2, clause 4): the location/test-site/traffic-conditions descriptions, the decision for the number of executed measurements, the reference speed meter, the R 91-2 requirements checklist (4.1/4.2/4.3/4.4/4.5/4.9), and the measurement results. Acceptance criterion: the integer speed values from the EUT shall fulfil the MPE for stationary measurements (OIML R 91-1, 6.4)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/field/stationary-field-test
|
|
7
|
+
section "R 91-3, pp. 19-20"
|
|
8
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/measuring-intervals /req/metrological/indicated-speed /req/category-moving/stationary-mode }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-metrological-field-test-oiml-r-91-2-4"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-1-traffic-condition-during-measurement-oiml-r-91-2-4-3"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-1-traffic-condition-during-measurement-oiml-r-91-2-4-3/table-1"
|
|
12
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-location"
|
|
13
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-test-site"
|
|
14
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-traffic-conditions"
|
|
15
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-number-of-measurements"
|
|
16
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-reference-speed-meter"
|
|
17
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-1-traffic-condition-during-measurement-oiml-r-91-2-4-3-continued"
|
|
18
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-1-traffic-condition-during-measurement-oiml-r-91-2-4-3-continued/table-1"
|
|
19
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-1-traffic-condition-during-measurement-oiml-r-91-2-4-3-continued/table-2"
|
|
20
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-4"
|
|
21
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-6.4"
|
|
22
|
+
report_rows { field conditions_checklist item_key requirement_ref }
|
|
23
|
+
field location : text {
|
|
24
|
+
label "Location"
|
|
25
|
+
description "Describe, using point form, the location (location, map, photos, …)"
|
|
26
|
+
required true
|
|
27
|
+
}
|
|
28
|
+
field test_site : text {
|
|
29
|
+
label "Test site"
|
|
30
|
+
description "Describe, using point form, the test site (road category, speed limits, …)"
|
|
31
|
+
required true
|
|
32
|
+
}
|
|
33
|
+
field traffic_conditions : text {
|
|
34
|
+
label "Traffic conditions"
|
|
35
|
+
description "Describe, using point form, the traffic conditions (traffic density, distance between vehicles, …)"
|
|
36
|
+
required true
|
|
37
|
+
}
|
|
38
|
+
field number_of_measurements_decision : text {
|
|
39
|
+
label "Number of measurements"
|
|
40
|
+
description "Describe, using point form, the decision for number of executed measurements"
|
|
41
|
+
required true
|
|
42
|
+
}
|
|
43
|
+
field reference_speed_meter : text {
|
|
44
|
+
label "Reference speed meter"
|
|
45
|
+
description "Describe, using point form, the used reference speed meter (manufacturer, type, serial, technology, traceability, …)"
|
|
46
|
+
required true
|
|
47
|
+
}
|
|
48
|
+
field conditions_checklist : array {
|
|
49
|
+
label "Checklist for traffic conditions (OIML R 91-2 requirements)"
|
|
50
|
+
description "One row per R 91-2 clause-4 requirement checked for this field test (4.1 General conditions, 4.2 Choice of test sites, 4.3 Traffic condition during measurement, 4.4 Number of measurements, 4.5 Reference speed meter, 4.9 Testing at speeds above the legal limit up to the maximum specified speed)"
|
|
51
|
+
required true
|
|
52
|
+
items { object fields {
|
|
53
|
+
field requirement_ref : string {
|
|
54
|
+
label "OIML R 91-2 clause"
|
|
55
|
+
required true
|
|
56
|
+
}
|
|
57
|
+
field requirement_text : string {
|
|
58
|
+
label "Requirement"
|
|
59
|
+
required true
|
|
60
|
+
}
|
|
61
|
+
field yes : boolean {
|
|
62
|
+
label "Yes"
|
|
63
|
+
measurement_method evaluated
|
|
64
|
+
}
|
|
65
|
+
field no : boolean {
|
|
66
|
+
label "No"
|
|
67
|
+
measurement_method evaluated
|
|
68
|
+
}
|
|
69
|
+
field remarks : text {
|
|
70
|
+
|
|
71
|
+
}
|
|
72
|
+
} }
|
|
73
|
+
}
|
|
74
|
+
field measurements : array {
|
|
75
|
+
description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
|
|
76
|
+
required true
|
|
77
|
+
subform_ref speed-measurement-row { }
|
|
78
|
+
}
|
|
79
|
+
field remarks : text {
|
|
80
|
+
|
|
81
|
+
}
|
|
82
|
+
pass_fail { criteria "The integer speed values from the EUT shall fulfil the MPE for stationary measurements (OIML R 91-1, 6.4)." pass_if "ocl{measurements->forAll(m | m.row_passed) and conditions_checklist->forAll(c | c.yes)}" }
|
|
83
|
+
}
|
|
84
|
+
|
|
@@ -0,0 +1,76 @@
|
|
|
1
|
+
form r91-3/report-1-2 {
|
|
2
|
+
name "1.2 Statistical analysis of errors (optional)"
|
|
3
|
+
description "R 91-3 test report, section 1.2 — the optional statistical analysis of the metrological field test errors (procedure per OIML R 91-2, 4.7): per speed subdivision, the mean deviation m and standard deviation σ of the field-test measurements with the confidence factor z. Acceptance criterion: for the subdivision the measurements from the metrological field test given above shall be used; the interval [m − zσ, m + zσ] shall be fully within the MPE for stationary measurements (OIML R 91-1, 6.4)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/field/stationary-field-test
|
|
7
|
+
section "R 91-3, p. 21"
|
|
8
|
+
requirements { /req/metrological/mpe-stationary }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-2-statistical-analysis-of-errors-optional-oiml-r-91-2-4-7"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-2-statistical-analysis-of-errors-optional-oiml-r-91-2-4-7/table-1"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion"
|
|
12
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-results"
|
|
13
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-results/table-1"
|
|
14
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-4.7"
|
|
15
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-6.4"
|
|
16
|
+
report_rows { field intervals item_key interval }
|
|
17
|
+
field z_factor : number {
|
|
18
|
+
label "Confidence factor z"
|
|
19
|
+
description "The factor z chosen as a measure of confidence for the interval [m − zσ, m + zσ]"
|
|
20
|
+
required true
|
|
21
|
+
measurement_method declared
|
|
22
|
+
}
|
|
23
|
+
field intervals : array {
|
|
24
|
+
label "Subdivision results"
|
|
25
|
+
description "One row per speed subdivision (Interval | Mean deviation m | Standard deviation σ | m−zσ | m+zσ | MPE | Pass | Fail)"
|
|
26
|
+
required true
|
|
27
|
+
items { object fields {
|
|
28
|
+
field interval : string {
|
|
29
|
+
label "Interval (e.g. 0km/h..50km/h)"
|
|
30
|
+
required true
|
|
31
|
+
}
|
|
32
|
+
field mean_deviation : number {
|
|
33
|
+
label "Mean deviation m [km/h]"
|
|
34
|
+
unit "km/h"
|
|
35
|
+
required true
|
|
36
|
+
measurement_method direct
|
|
37
|
+
}
|
|
38
|
+
field std_deviation : number {
|
|
39
|
+
label "Standard deviation σ [km/h]"
|
|
40
|
+
unit "km/h"
|
|
41
|
+
required true
|
|
42
|
+
measurement_method direct
|
|
43
|
+
}
|
|
44
|
+
field interval_low : number {
|
|
45
|
+
label "m−zσ [km/h]"
|
|
46
|
+
unit "km/h"
|
|
47
|
+
required true
|
|
48
|
+
measurement_method direct
|
|
49
|
+
}
|
|
50
|
+
field interval_high : number {
|
|
51
|
+
label "m+zσ [km/h]"
|
|
52
|
+
unit "km/h"
|
|
53
|
+
required true
|
|
54
|
+
measurement_method direct
|
|
55
|
+
}
|
|
56
|
+
field mpe : number {
|
|
57
|
+
label "MPE [km/h]"
|
|
58
|
+
unit "km/h"
|
|
59
|
+
required true
|
|
60
|
+
measurement_method direct
|
|
61
|
+
}
|
|
62
|
+
field row_passed : boolean {
|
|
63
|
+
label "Row result"
|
|
64
|
+
required true
|
|
65
|
+
measurement_method evaluated
|
|
66
|
+
true_label "Pass"
|
|
67
|
+
false_label "Fail"
|
|
68
|
+
}
|
|
69
|
+
} }
|
|
70
|
+
}
|
|
71
|
+
field remarks : text {
|
|
72
|
+
|
|
73
|
+
}
|
|
74
|
+
pass_fail { criteria "For the subdivision the measurements from the metrological field test given above shall be used. The interval [m - z sigma, m + z sigma] shall be fully within the MPE for stationary measurements (OIML R 91-1, 6.4)." pass_if "ocl{intervals->forAll(i | i.row_passed)}" }
|
|
75
|
+
}
|
|
76
|
+
|
|
@@ -0,0 +1,30 @@
|
|
|
1
|
+
form r91-3/report-1-3 {
|
|
2
|
+
name "1.3 Assignment to image evidence"
|
|
3
|
+
description "R 91-3 test report, section 1.3 — the assignment of the field-test measurements to the image evidence (procedure per OIML R 91-2, 4.8): examples of evidence photos supporting the certainty of vehicle identification (R 91-1, 6.6)"
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/field/stationary-field-test
|
|
7
|
+
section "R 91-3, p. 22"
|
|
8
|
+
requirements { /req/metrological/vehicle-identification }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-1-3-assignment-to-image-evidence-oiml-r-91-2-4-8"
|
|
10
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-4.8"
|
|
11
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-6.6"
|
|
12
|
+
field evidence_photos : array {
|
|
13
|
+
label "Examples of evidence photos"
|
|
14
|
+
description "References to the evidence-photo artifacts assigned to the field-test measurements (artifact instance ids)"
|
|
15
|
+
items { string }
|
|
16
|
+
}
|
|
17
|
+
field vehicle_identification_supported : boolean {
|
|
18
|
+
label "Image evidence supports the certainty of vehicle identification"
|
|
19
|
+
required true
|
|
20
|
+
measurement_method evaluated
|
|
21
|
+
targets { /req/metrological/vehicle-identification }
|
|
22
|
+
true_label "Pass"
|
|
23
|
+
false_label "Fail"
|
|
24
|
+
}
|
|
25
|
+
field remarks : text {
|
|
26
|
+
|
|
27
|
+
}
|
|
28
|
+
pass_fail { criteria "The field-test measurements are assigned to image evidence supporting the certainty of vehicle identification (OIML R 91-1, 6.6; procedure per OIML R 91-2, 4.8)." pass_if "ocl{vehicle_identification_supported}" }
|
|
29
|
+
}
|
|
30
|
+
|
|
@@ -0,0 +1,92 @@
|
|
|
1
|
+
form r91-3/report-2-1 {
|
|
2
|
+
name "2.1 Dynamic performance test"
|
|
3
|
+
description "R 91-3 test report, section 2.1 — the dynamic performance test record (procedure per OIML R 91-2, 5.3): the R 91-2 requirements checklist (5.1 General conditions, 5.2 Characteristics of the traffic simulator) and the measurement results with the reference acceleration. Acceptance criterion: the integer speed values from the EUT shall fulfil the MPE for stationary measurements (OIML R 91-1, 6.4)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/field/dynamic-performance
|
|
7
|
+
section "R 91-3, p. 23"
|
|
8
|
+
requirements { /req/metrological/mpe-stationary /req/metrological/relevant-speed-values }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-metrological-laboratory-tests-by-traffic-simulation-oiml-r-91-2-5"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-1-dynamic-performance-test-oiml-r-91-2-5-3"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-1-dynamic-performance-test-oiml-r-91-2-5-3/table-1"
|
|
12
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-1-dynamic-performance-test-oiml-r-91-2-5-3/table-2"
|
|
13
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-1-dynamic-performance-test-oiml-r-91-2-5-3/table-3"
|
|
14
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-5.3"
|
|
15
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-6.4"
|
|
16
|
+
report_rows { field conditions_checklist item_key requirement_ref }
|
|
17
|
+
field conditions_checklist : array {
|
|
18
|
+
label "Checklist for conditions (OIML R 91-2 requirements)"
|
|
19
|
+
description "One row per R 91-2 clause-5 requirement checked for this test (5.1 General conditions, 5.2 Characteristics of the traffic simulator)"
|
|
20
|
+
required true
|
|
21
|
+
items { object fields {
|
|
22
|
+
field requirement_ref : string {
|
|
23
|
+
label "OIML R 91-2 clause"
|
|
24
|
+
required true
|
|
25
|
+
}
|
|
26
|
+
field requirement_text : string {
|
|
27
|
+
label "Requirement"
|
|
28
|
+
required true
|
|
29
|
+
}
|
|
30
|
+
field yes : boolean {
|
|
31
|
+
label "Yes"
|
|
32
|
+
measurement_method evaluated
|
|
33
|
+
}
|
|
34
|
+
field no : boolean {
|
|
35
|
+
label "No"
|
|
36
|
+
measurement_method evaluated
|
|
37
|
+
}
|
|
38
|
+
field remarks : text {
|
|
39
|
+
|
|
40
|
+
}
|
|
41
|
+
} }
|
|
42
|
+
}
|
|
43
|
+
field measurements : array {
|
|
44
|
+
description "Results-table rows (Measurement No. | v | vref | aref | Δv | MPE | Pass | Fail)"
|
|
45
|
+
required true
|
|
46
|
+
items { object fields {
|
|
47
|
+
field measurement_no : integer {
|
|
48
|
+
label "Measurement No."
|
|
49
|
+
required true
|
|
50
|
+
}
|
|
51
|
+
field indicated_speed : number {
|
|
52
|
+
label "v [km/h]"
|
|
53
|
+
unit "km/h"
|
|
54
|
+
required true
|
|
55
|
+
measurement_method direct
|
|
56
|
+
}
|
|
57
|
+
field reference_speed : number {
|
|
58
|
+
label "vref [km/h]"
|
|
59
|
+
unit "km/h"
|
|
60
|
+
required true
|
|
61
|
+
measurement_method direct
|
|
62
|
+
}
|
|
63
|
+
field reference_acceleration : number {
|
|
64
|
+
label "aref [m/s²]"
|
|
65
|
+
unit "m/s2"
|
|
66
|
+
measurement_method direct
|
|
67
|
+
}
|
|
68
|
+
field speed_error : number {
|
|
69
|
+
label "Δv [km/h]"
|
|
70
|
+
unit "km/h"
|
|
71
|
+
measurement_method direct
|
|
72
|
+
}
|
|
73
|
+
field mpe : number {
|
|
74
|
+
label "MPE [km/h]"
|
|
75
|
+
unit "km/h"
|
|
76
|
+
measurement_method direct
|
|
77
|
+
}
|
|
78
|
+
field row_passed : boolean {
|
|
79
|
+
label "Row result"
|
|
80
|
+
required true
|
|
81
|
+
measurement_method evaluated
|
|
82
|
+
true_label "Pass"
|
|
83
|
+
false_label "Fail"
|
|
84
|
+
}
|
|
85
|
+
} }
|
|
86
|
+
}
|
|
87
|
+
field remarks : text {
|
|
88
|
+
|
|
89
|
+
}
|
|
90
|
+
pass_fail { criteria "The integer speed values from the EUT shall fulfil the MPE for stationary measurements (OIML R 91-1, 6.4)." pass_if "ocl{measurements->forAll(m | m.row_passed) and conditions_checklist->forAll(c | c.yes)}" }
|
|
91
|
+
}
|
|
92
|
+
|
|
@@ -0,0 +1,23 @@
|
|
|
1
|
+
form r91-3/report-2-2 {
|
|
2
|
+
name "2.2 Speed linearity test"
|
|
3
|
+
description "R 91-3 test report, section 2.2 — the speed linearity test record (procedure per OIML R 91-2, 5.4). Acceptance criterion: the high-resolution speed values from the EUT shall fulfil the linearity error limit (OIML R 91-1, 6.5)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/linearities/speed-linearity
|
|
7
|
+
section "R 91-3, p. 24"
|
|
8
|
+
requirements { /req/metrological/linearity-limit }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-2-speed-linearity-test-oiml-r-91-2-5-4"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-2-speed-linearity-test-oiml-r-91-2-5-4/table-1"
|
|
11
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-5.4"
|
|
12
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-6.5"
|
|
13
|
+
field measurements : array {
|
|
14
|
+
description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
|
|
15
|
+
required true
|
|
16
|
+
subform_ref speed-measurement-row { }
|
|
17
|
+
}
|
|
18
|
+
field remarks : text {
|
|
19
|
+
|
|
20
|
+
}
|
|
21
|
+
pass_fail { criteria "The high-resolution speed values from the EUT shall fulfil the linearity error limit (OIML R 91-1, 6.5)." pass_if "ocl{measurements->forAll(m | m.row_passed)}" }
|
|
22
|
+
}
|
|
23
|
+
|
|
@@ -0,0 +1,67 @@
|
|
|
1
|
+
form r91-3/report-2-3 {
|
|
2
|
+
name "2.3 Distance linearity test"
|
|
3
|
+
description "R 91-3 test report, section 2.3 — the distance linearity test record (procedure per OIML R 91-2, 5.5). Acceptance criterion: the distance values from the EUT shall fulfil the error limit specified by the manufacturer. The reference speed for this kind of test should be 0 km/h."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/linearities/distance-linearity
|
|
7
|
+
section "R 91-3, p. 25"
|
|
8
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-3-distance-linearity-test-oiml-r-91-2-5-5"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-3-distance-linearity-test-oiml-r-91-2-5-5/table-1"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-3-distance-linearity-test-oiml-r-91-2-5-5/table-2"
|
|
12
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-5.5"
|
|
13
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-6.7"
|
|
14
|
+
field reference_speed : number {
|
|
15
|
+
label "Reference speed [km/h]"
|
|
16
|
+
description "The reference speed for this kind of test should be 0 km/h"
|
|
17
|
+
unit "km/h"
|
|
18
|
+
required true
|
|
19
|
+
measurement_method declared
|
|
20
|
+
default 0
|
|
21
|
+
}
|
|
22
|
+
field measurements : array {
|
|
23
|
+
description "Results-table rows (Measurement No. | d [m] | d_ref [m] | Δd [m] | MPE [m] | Pass | Fail)"
|
|
24
|
+
required true
|
|
25
|
+
items { object fields {
|
|
26
|
+
field measurement_no : integer {
|
|
27
|
+
label "Measurement No."
|
|
28
|
+
required true
|
|
29
|
+
}
|
|
30
|
+
field indicated_distance : number {
|
|
31
|
+
label "d [m]"
|
|
32
|
+
unit "m"
|
|
33
|
+
required true
|
|
34
|
+
measurement_method direct
|
|
35
|
+
}
|
|
36
|
+
field reference_distance : number {
|
|
37
|
+
label "d_ref [m]"
|
|
38
|
+
unit "m"
|
|
39
|
+
required true
|
|
40
|
+
measurement_method direct
|
|
41
|
+
}
|
|
42
|
+
field distance_error : number {
|
|
43
|
+
label "Δd [m]"
|
|
44
|
+
unit "m"
|
|
45
|
+
measurement_method direct
|
|
46
|
+
}
|
|
47
|
+
field error_limit : number {
|
|
48
|
+
label "MPE [m] — the error limit specified by the manufacturer"
|
|
49
|
+
unit "m"
|
|
50
|
+
required true
|
|
51
|
+
measurement_method declared
|
|
52
|
+
}
|
|
53
|
+
field row_passed : boolean {
|
|
54
|
+
label "Row result"
|
|
55
|
+
required true
|
|
56
|
+
measurement_method evaluated
|
|
57
|
+
true_label "Pass"
|
|
58
|
+
false_label "Fail"
|
|
59
|
+
}
|
|
60
|
+
} }
|
|
61
|
+
}
|
|
62
|
+
field remarks : text {
|
|
63
|
+
|
|
64
|
+
}
|
|
65
|
+
pass_fail { criteria "The distance values from the EUT shall fulfil the error limit specified by the manufacturer." pass_if "ocl{measurements->forAll(m | m.row_passed)}" }
|
|
66
|
+
}
|
|
67
|
+
|
|
@@ -0,0 +1,59 @@
|
|
|
1
|
+
form r91-3/report-2-4 {
|
|
2
|
+
name "2.4 Angle linearity test"
|
|
3
|
+
description "R 91-3 test report, section 2.4 — the angle linearity test record (procedure per OIML R 91-2, 5.6). Acceptance criterion: the angle values from the EUT shall fulfil the error limit specified by the manufacturer."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/linearities/angle-linearity
|
|
7
|
+
section "R 91-3, p. 26"
|
|
8
|
+
requirements { /req/metrological/distance-angle-indication }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-4-angle-linearity-test-oiml-r-91-2-5-6"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-4-angle-linearity-test-oiml-r-91-2-5-6/table-1"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-2-4-angle-linearity-test-oiml-r-91-2-5-6/table-2"
|
|
12
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-5.6"
|
|
13
|
+
ref requirement "urn:oiml:pub:r:91-1:2025#clause-6.7"
|
|
14
|
+
field measurements : array {
|
|
15
|
+
description "Results-table rows (Measurement No. | α [°] | α_ref [°] | Δα [°] | MPE [°] | Pass | Fail)"
|
|
16
|
+
required true
|
|
17
|
+
items { object fields {
|
|
18
|
+
field measurement_no : integer {
|
|
19
|
+
label "Measurement No."
|
|
20
|
+
required true
|
|
21
|
+
}
|
|
22
|
+
field indicated_angle : number {
|
|
23
|
+
label "α [°]"
|
|
24
|
+
unit "deg"
|
|
25
|
+
required true
|
|
26
|
+
measurement_method direct
|
|
27
|
+
}
|
|
28
|
+
field reference_angle : number {
|
|
29
|
+
label "α_ref [°]"
|
|
30
|
+
unit "deg"
|
|
31
|
+
required true
|
|
32
|
+
measurement_method direct
|
|
33
|
+
}
|
|
34
|
+
field angle_error : number {
|
|
35
|
+
label "Δα [°]"
|
|
36
|
+
unit "deg"
|
|
37
|
+
measurement_method direct
|
|
38
|
+
}
|
|
39
|
+
field error_limit : number {
|
|
40
|
+
label "MPE [°] — the error limit specified by the manufacturer"
|
|
41
|
+
unit "deg"
|
|
42
|
+
required true
|
|
43
|
+
measurement_method declared
|
|
44
|
+
}
|
|
45
|
+
field row_passed : boolean {
|
|
46
|
+
label "Row result"
|
|
47
|
+
required true
|
|
48
|
+
measurement_method evaluated
|
|
49
|
+
true_label "Pass"
|
|
50
|
+
false_label "Fail"
|
|
51
|
+
}
|
|
52
|
+
} }
|
|
53
|
+
}
|
|
54
|
+
field remarks : text {
|
|
55
|
+
|
|
56
|
+
}
|
|
57
|
+
pass_fail { criteria "The angle values from the EUT shall fulfil the error limit specified by the manufacturer." pass_if "ocl{measurements->forAll(m | m.row_passed)}" }
|
|
58
|
+
}
|
|
59
|
+
|
|
@@ -0,0 +1,38 @@
|
|
|
1
|
+
form r91-3/report-3-1 {
|
|
2
|
+
name "3.1 Dry heat (operating)"
|
|
3
|
+
description "R 91-3 test report, section 3.1 — the dry heat (operating) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/influence/dry-heat-operating
|
|
7
|
+
section "R 91-3, p. 27"
|
|
8
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-1-dry-heat-operating"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-1-dry-heat-operating/table-1"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-1-dry-heat-operating/table-2"
|
|
12
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-influence-factor-and-disturbance-tests-oiml-r-91-2-clause-6"
|
|
13
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
|
|
14
|
+
field measurements : array {
|
|
15
|
+
description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
|
|
16
|
+
required true
|
|
17
|
+
subform_ref speed-measurement-row { }
|
|
18
|
+
}
|
|
19
|
+
field evidence_files_intact : boolean {
|
|
20
|
+
label "Evidence files intact"
|
|
21
|
+
description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
|
|
22
|
+
required true
|
|
23
|
+
measurement_method evaluated
|
|
24
|
+
targets { /req/metrological/linearity-limit }
|
|
25
|
+
true_label "Pass"
|
|
26
|
+
false_label "Fail"
|
|
27
|
+
}
|
|
28
|
+
field d11_reference : string {
|
|
29
|
+
label "Reference to OIML D 11:2013"
|
|
30
|
+
description "D 11 test-method reference recorded on the report form (clause 6)"
|
|
31
|
+
default "clause 6"
|
|
32
|
+
}
|
|
33
|
+
field remarks : text {
|
|
34
|
+
|
|
35
|
+
}
|
|
36
|
+
pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
|
|
37
|
+
}
|
|
38
|
+
|
|
@@ -0,0 +1,48 @@
|
|
|
1
|
+
form r91-3/report-3-2 {
|
|
2
|
+
name "3.2 Dry heat (storage)"
|
|
3
|
+
description "R 91-3 test report, section 3.2 — the dry heat (storage) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFa No significant fault occurred after the disturbance. The EUT shall continue to operate as intended after the test (manual intervention allowed)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/disturbances/dry-heat-storage
|
|
7
|
+
section "R 91-3, p. 28"
|
|
8
|
+
requirements { /req/metrological/disturbances }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-2-dry-heat-storage"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-2-dry-heat-storage/table-1"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-2"
|
|
12
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-2"
|
|
13
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-2/table-1"
|
|
14
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks"
|
|
15
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
|
|
16
|
+
field measurements : array {
|
|
17
|
+
description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
|
|
18
|
+
required true
|
|
19
|
+
subform_ref speed-measurement-row { }
|
|
20
|
+
}
|
|
21
|
+
field no_significant_fault : boolean {
|
|
22
|
+
label "No significant fault (NSFa)"
|
|
23
|
+
description "No significant fault occurred after the disturbance"
|
|
24
|
+
required true
|
|
25
|
+
measurement_method evaluated
|
|
26
|
+
targets { /req/metrological/disturbances }
|
|
27
|
+
true_label "Pass"
|
|
28
|
+
false_label "Fail"
|
|
29
|
+
}
|
|
30
|
+
field eut_operates_after : boolean {
|
|
31
|
+
label "EUT operates as intended after the test (manual intervention allowed)"
|
|
32
|
+
required true
|
|
33
|
+
measurement_method evaluated
|
|
34
|
+
targets { /req/metrological/disturbances }
|
|
35
|
+
true_label "Pass"
|
|
36
|
+
false_label "Fail"
|
|
37
|
+
}
|
|
38
|
+
field d11_reference : string {
|
|
39
|
+
label "Reference to OIML D 11:2013"
|
|
40
|
+
description "D 11 test-method reference recorded on the report form (clause 6)"
|
|
41
|
+
default "clause 6"
|
|
42
|
+
}
|
|
43
|
+
field remarks : text {
|
|
44
|
+
|
|
45
|
+
}
|
|
46
|
+
pass_fail { criteria "NSFa No significant fault occurred after the disturbance. The EUT shall continue to operate as intended after the test (manual intervention allowed)." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
|
|
47
|
+
}
|
|
48
|
+
|
|
@@ -0,0 +1,40 @@
|
|
|
1
|
+
form r91-3/report-3-3 {
|
|
2
|
+
name "3.3 Cold (operating)"
|
|
3
|
+
description "R 91-3 test report, section 3.3 — the cold (operating) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
|
|
4
|
+
data_class FormInstance#data
|
|
5
|
+
header r91-3/header-a
|
|
6
|
+
conformance_process /conf/influence/cold-operating
|
|
7
|
+
section "R 91-3, p. 29"
|
|
8
|
+
requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
|
|
9
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-3-cold-operating"
|
|
10
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-3-cold-operating/table-1"
|
|
11
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-3"
|
|
12
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-3"
|
|
13
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-3/table-1"
|
|
14
|
+
ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-2"
|
|
15
|
+
ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
|
|
16
|
+
field measurements : array {
|
|
17
|
+
description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
|
|
18
|
+
required true
|
|
19
|
+
subform_ref speed-measurement-row { }
|
|
20
|
+
}
|
|
21
|
+
field evidence_files_intact : boolean {
|
|
22
|
+
label "Evidence files intact"
|
|
23
|
+
description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
|
|
24
|
+
required true
|
|
25
|
+
measurement_method evaluated
|
|
26
|
+
targets { /req/metrological/linearity-limit }
|
|
27
|
+
true_label "Pass"
|
|
28
|
+
false_label "Fail"
|
|
29
|
+
}
|
|
30
|
+
field d11_reference : string {
|
|
31
|
+
label "Reference to OIML D 11:2013"
|
|
32
|
+
description "D 11 test-method reference recorded on the report form (clause 7)"
|
|
33
|
+
default "clause 7"
|
|
34
|
+
}
|
|
35
|
+
field remarks : text {
|
|
36
|
+
|
|
37
|
+
}
|
|
38
|
+
pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
|
|
39
|
+
}
|
|
40
|
+
|