@oimlsmart/primmel-packages 0.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (460) hide show
  1. package/AGENTS.md +60 -0
  2. package/LICENSE +21 -0
  3. package/README.md +68 -0
  4. package/acme-cgm-200/model/cgm200.prl +284 -0
  5. package/acme-cgm-200/model/r144-map.prl +337 -0
  6. package/acme-cgm-200/package.primmel +39 -0
  7. package/acme-cgm-system/model/cgm-system.prl +125 -0
  8. package/acme-cgm-system/model/r144-map.prl +75 -0
  9. package/acme-cgm-system/model/sample-line.prl +42 -0
  10. package/acme-cgm-system/package.primmel +23 -0
  11. package/acme-lc500/model/lc500.prl +218 -0
  12. package/acme-lc500/model/passport.prl +43 -0
  13. package/acme-lc500/model/r60-map.prl +161 -0
  14. package/acme-lc500/model/twin-cert-map.prl +114 -0
  15. package/acme-lc500/package.primmel +35 -0
  16. package/acme-md3xx/model/md350.prl +317 -0
  17. package/acme-md3xx/model/r129-map.prl +346 -0
  18. package/acme-md3xx/package.primmel +49 -0
  19. package/acme-rs180/model/r91-map.prl +234 -0
  20. package/acme-rs180/model/rs180.prl +236 -0
  21. package/acme-rs180/package.primmel +47 -0
  22. package/ims-demo/model/ims.prl +23 -0
  23. package/ims-demo/model/isms-map.prl +60 -0
  24. package/ims-demo/model/qms-map.prl +73 -0
  25. package/ims-demo/package.primmel +42 -0
  26. package/isms-ref/model/isms.prl +34 -0
  27. package/isms-ref/package.primmel +35 -0
  28. package/iso-iec-17000/package.primmel +8 -0
  29. package/iso-iec-17000/terminology.prl +268 -0
  30. package/iso-iec-17025/package.primmel +10 -0
  31. package/iso-iec-17025/specification/requirements/lab.prl +474 -0
  32. package/iso-iec-17025/terminology.prl +72 -0
  33. package/iso-iec-17065/package.primmel +10 -0
  34. package/iso-iec-17065/specification/requirements/body.prl +446 -0
  35. package/iso-iec-17065/terminology.prl +103 -0
  36. package/iso-iec-17067/package.primmel +10 -0
  37. package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
  38. package/iso-iec-17067/terminology.prl +24 -0
  39. package/oiml-cs/package.primmel +10 -0
  40. package/oiml-cs/specification/discrepancies.prl +26 -0
  41. package/oiml-cs/specification/requirements/cs.prl +515 -0
  42. package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
  43. package/oiml-cs-dataspace/package.primmel +9 -0
  44. package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
  45. package/oiml-cs-dataspace/specification/policies.prl +68 -0
  46. package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
  47. package/oiml-integrated-ref/package.primmel +10 -0
  48. package/oiml-r129/.primmel-allowlist.prl +2 -0
  49. package/oiml-r129/evaluation/processes.prl +152 -0
  50. package/oiml-r129/evaluation/workflow.prl +48 -0
  51. package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
  52. package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
  53. package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
  54. package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
  55. package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
  56. package/oiml-r129/execution/forms/admin/identification.prl +49 -0
  57. package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
  58. package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
  59. package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
  60. package/oiml-r129/execution/forms/emc/esd.prl +66 -0
  61. package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
  62. package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
  63. package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
  64. package/oiml-r129/execution/forms/emc/surge.prl +61 -0
  65. package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
  66. package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
  67. package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
  68. package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
  69. package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
  70. package/oiml-r129/execution/forms/shared/headers.prl +86 -0
  71. package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
  72. package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
  73. package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
  74. package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
  75. package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
  76. package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
  77. package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
  78. package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
  79. package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
  80. package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
  81. package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
  82. package/oiml-r129/layers.prl +50 -0
  83. package/oiml-r129/model/attributes.prl +243 -0
  84. package/oiml-r129/model/behaviors.prl +79 -0
  85. package/oiml-r129/model/capabilities.prl +29 -0
  86. package/oiml-r129/model/characteristics.prl +8 -0
  87. package/oiml-r129/model/conditions.prl +23 -0
  88. package/oiml-r129/model/instrument.prl +67 -0
  89. package/oiml-r129/model/state.prl +22 -0
  90. package/oiml-r129/model/twin.prl +23 -0
  91. package/oiml-r129/package.primmel +15 -0
  92. package/oiml-r129/payload/application.yaml +40 -0
  93. package/oiml-r129/payload/conditions-common-test.yaml +8 -0
  94. package/oiml-r129/payload/formulas-variants.yaml +33 -0
  95. package/oiml-r129/payload/promises.yaml +102 -0
  96. package/oiml-r129/payload/sample-data.yaml +300 -0
  97. package/oiml-r129/references.prl +306 -0
  98. package/oiml-r129/sources-prd/coverage.json +59 -0
  99. package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
  100. package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
  101. package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
  102. package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
  103. package/oiml-r129/specification/calculations.prl +83 -0
  104. package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
  105. package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
  106. package/oiml-r129/specification/conformance/examinations.prl +83 -0
  107. package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
  108. package/oiml-r129/specification/formulas.prl +9 -0
  109. package/oiml-r129/specification/requirements/electronic.prl +46 -0
  110. package/oiml-r129/specification/requirements/metrological.prl +83 -0
  111. package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
  112. package/oiml-r129/specification/requirements/software.prl +57 -0
  113. package/oiml-r129/specification/requirements/technical.prl +134 -0
  114. package/oiml-r129/specification/symbols.prl +187 -0
  115. package/oiml-r129/specification/tables.prl +74 -0
  116. package/oiml-r129/terminology.prl +415 -0
  117. package/oiml-r129/value-types.prl +40 -0
  118. package/oiml-r144/.primmel-allowlist.prl +2 -0
  119. package/oiml-r144/entities/instrument.prl +360 -0
  120. package/oiml-r144/entities/test-execution.prl +228 -0
  121. package/oiml-r144/entities/workflow.prl +2075 -0
  122. package/oiml-r144/evaluation/processes.prl +152 -0
  123. package/oiml-r144/evaluation/workflow.prl +48 -0
  124. package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
  125. package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
  126. package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
  127. package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
  128. package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
  129. package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
  130. package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
  131. package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
  132. package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
  133. package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
  134. package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
  135. package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
  136. package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
  137. package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
  138. package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
  139. package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
  140. package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
  141. package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
  142. package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
  143. package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
  144. package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
  145. package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
  146. package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
  147. package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
  148. package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
  149. package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
  150. package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
  151. package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
  152. package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
  153. package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
  154. package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
  155. package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
  156. package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
  157. package/oiml-r144/execution/forms/shared/headers.prl +132 -0
  158. package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
  159. package/oiml-r144/layers.prl +44 -0
  160. package/oiml-r144/model/attributes.prl +679 -0
  161. package/oiml-r144/model/behaviors.prl +117 -0
  162. package/oiml-r144/model/capabilities.prl +99 -0
  163. package/oiml-r144/model/characteristics.prl +27 -0
  164. package/oiml-r144/model/conditions.prl +46 -0
  165. package/oiml-r144/model/instrument.prl +85 -0
  166. package/oiml-r144/model/state.prl +18 -0
  167. package/oiml-r144/model/twin.prl +25 -0
  168. package/oiml-r144/package.primmel +15 -0
  169. package/oiml-r144/payload/application.yaml +80 -0
  170. package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
  171. package/oiml-r144/payload/conditions-common-test.yaml +74 -0
  172. package/oiml-r144/payload/formulas-variants.yaml +32 -0
  173. package/oiml-r144/payload/promises.yaml +118 -0
  174. package/oiml-r144/payload/sample-data.yaml +643 -0
  175. package/oiml-r144/references.prl +594 -0
  176. package/oiml-r144/sources-prd/coverage.json +114 -0
  177. package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
  178. package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
  179. package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
  180. package/oiml-r144/specification/calculations.prl +123 -0
  181. package/oiml-r144/specification/conformance/examination.prl +87 -0
  182. package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
  183. package/oiml-r144/specification/formulas.prl +37 -0
  184. package/oiml-r144/specification/reference-materials.prl +87 -0
  185. package/oiml-r144/specification/requirements/controls.prl +51 -0
  186. package/oiml-r144/specification/requirements/metrological.prl +299 -0
  187. package/oiml-r144/specification/requirements/report.prl +35 -0
  188. package/oiml-r144/specification/requirements/technical.prl +455 -0
  189. package/oiml-r144/specification/symbols.prl +357 -0
  190. package/oiml-r144/specification/tables.prl +95 -0
  191. package/oiml-r144/specification/test-point-sets.prl +15 -0
  192. package/oiml-r144/terminology.prl +308 -0
  193. package/oiml-r144/value-types.prl +49 -0
  194. package/oiml-r60/.primmel-allowlist.prl +2 -0
  195. package/oiml-r60/entities/workflow.prl +2079 -0
  196. package/oiml-r60/evaluation/processes.prl +152 -0
  197. package/oiml-r60/evaluation/workflow.prl +48 -0
  198. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
  199. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
  200. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
  201. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
  202. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
  203. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
  204. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
  205. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
  206. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
  207. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
  208. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
  209. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
  210. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
  211. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
  212. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
  213. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
  214. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
  215. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
  216. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
  217. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
  218. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
  219. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
  220. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
  221. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
  222. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
  223. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
  224. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
  225. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
  226. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
  227. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
  228. package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
  229. package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
  230. package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
  231. package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
  232. package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
  233. package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
  234. package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
  235. package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
  236. package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
  237. package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
  238. package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
  239. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
  240. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
  241. package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
  242. package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
  243. package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
  244. package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
  245. package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
  246. package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
  247. package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
  248. package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
  249. package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
  250. package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
  251. package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
  252. package/oiml-r60/execution/forms/shared/headers.prl +255 -0
  253. package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
  254. package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
  255. package/oiml-r60/layers.prl +46 -0
  256. package/oiml-r60/model/attributes.prl +642 -0
  257. package/oiml-r60/model/behaviors.prl +165 -0
  258. package/oiml-r60/model/capabilities.prl +57 -0
  259. package/oiml-r60/model/characteristics.prl +27 -0
  260. package/oiml-r60/model/conditions.prl +50 -0
  261. package/oiml-r60/model/instrument.prl +96 -0
  262. package/oiml-r60/model/processes.prl +54 -0
  263. package/oiml-r60/model/state.prl +22 -0
  264. package/oiml-r60/model/twin.prl +16 -0
  265. package/oiml-r60/package.primmel +16 -0
  266. package/oiml-r60/payload/annexes-part4.yaml +122 -0
  267. package/oiml-r60/payload/application.yaml +83 -0
  268. package/oiml-r60/payload/conditions-common-test.yaml +121 -0
  269. package/oiml-r60/payload/formulas-variants.yaml +55 -0
  270. package/oiml-r60/payload/promises.yaml +224 -0
  271. package/oiml-r60/payload/sample-data.yaml +5025 -0
  272. package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
  273. package/oiml-r60/references.prl +549 -0
  274. package/oiml-r60/sources-prd/coverage.json +740 -0
  275. package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
  276. package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
  277. package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
  278. package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
  279. package/oiml-r60/specification/calculations.prl +318 -0
  280. package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
  281. package/oiml-r60/specification/conformance/electronic.prl +483 -0
  282. package/oiml-r60/specification/conformance/examination.prl +183 -0
  283. package/oiml-r60/specification/conformance/metrological.prl +478 -0
  284. package/oiml-r60/specification/constraints.prl +58 -0
  285. package/oiml-r60/specification/formulas-used.prl +43 -0
  286. package/oiml-r60/specification/formulas.prl +20 -0
  287. package/oiml-r60/specification/requirements/class-specific.prl +655 -0
  288. package/oiml-r60/specification/requirements/classification.prl +114 -0
  289. package/oiml-r60/specification/requirements/electronic.prl +222 -0
  290. package/oiml-r60/specification/requirements/metrological.prl +381 -0
  291. package/oiml-r60/specification/requirements/technical.prl +146 -0
  292. package/oiml-r60/specification/symbols.prl +599 -0
  293. package/oiml-r60/specification/tables.prl +182 -0
  294. package/oiml-r60/specification/test-sequences.prl +72 -0
  295. package/oiml-r60/terminology.prl +920 -0
  296. package/oiml-r60/value-types.prl +46 -0
  297. package/oiml-r91/.primmel-allowlist.prl +3 -0
  298. package/oiml-r91/entities/instrument.prl +359 -0
  299. package/oiml-r91/entities/workflow.prl +2075 -0
  300. package/oiml-r91/evaluation/processes.prl +152 -0
  301. package/oiml-r91/evaluation/workflow.prl +48 -0
  302. package/oiml-r91/execution/forms/evidence-file.prl +41 -0
  303. package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
  304. package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
  305. package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
  306. package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
  307. package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
  308. package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
  309. package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
  310. package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
  311. package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
  312. package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
  313. package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
  314. package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
  315. package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
  316. package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
  317. package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
  318. package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
  319. package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
  320. package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
  321. package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
  322. package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
  323. package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
  324. package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
  325. package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
  326. package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
  327. package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
  328. package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
  329. package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
  330. package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
  331. package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
  332. package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
  333. package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
  334. package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
  335. package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
  336. package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
  337. package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
  338. package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
  339. package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
  340. package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
  341. package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
  342. package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
  343. package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
  344. package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
  345. package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
  346. package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
  347. package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
  348. package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
  349. package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
  350. package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
  351. package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
  352. package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
  353. package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
  354. package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
  355. package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
  356. package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
  357. package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
  358. package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
  359. package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
  360. package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
  361. package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
  362. package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
  363. package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
  364. package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
  365. package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
  366. package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
  367. package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
  368. package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
  369. package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
  370. package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
  371. package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
  372. package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
  373. package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
  374. package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
  375. package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
  376. package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
  377. package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
  378. package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
  379. package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
  380. package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
  381. package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
  382. package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
  383. package/oiml-r91/layers.prl +46 -0
  384. package/oiml-r91/model/artifacts.prl +29 -0
  385. package/oiml-r91/model/attributes.prl +698 -0
  386. package/oiml-r91/model/behaviors.prl +142 -0
  387. package/oiml-r91/model/capabilities.prl +88 -0
  388. package/oiml-r91/model/characteristics.prl +27 -0
  389. package/oiml-r91/model/conditions.prl +37 -0
  390. package/oiml-r91/model/instrument.prl +147 -0
  391. package/oiml-r91/model/state.prl +22 -0
  392. package/oiml-r91/model/twin.prl +17 -0
  393. package/oiml-r91/package.primmel +14 -0
  394. package/oiml-r91/payload/application.yaml +201 -0
  395. package/oiml-r91/payload/conditions-common-test.yaml +19 -0
  396. package/oiml-r91/payload/promises.yaml +142 -0
  397. package/oiml-r91/payload/sample-data.yaml +464 -0
  398. package/oiml-r91/references.prl +72 -0
  399. package/oiml-r91/sources-prd/coverage.json +106 -0
  400. package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
  401. package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
  402. package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
  403. package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
  404. package/oiml-r91/specification/calculations.prl +26 -0
  405. package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
  406. package/oiml-r91/specification/conformance/metrological.prl +906 -0
  407. package/oiml-r91/specification/formulas.prl +10 -0
  408. package/oiml-r91/specification/requirements/class-specific.prl +308 -0
  409. package/oiml-r91/specification/requirements/metrological.prl +176 -0
  410. package/oiml-r91/specification/requirements/technical.prl +173 -0
  411. package/oiml-r91/specification/symbols.prl +323 -0
  412. package/oiml-r91/specification/tables.prl +136 -0
  413. package/oiml-r91/terminology.prl +535 -0
  414. package/oiml-r91/value-types.prl +26 -0
  415. package/oiml-smart-core/entities/comments.prl +101 -0
  416. package/oiml-smart-core/entities/cs-operations.prl +492 -0
  417. package/oiml-smart-core/entities/cs-participants.prl +470 -0
  418. package/oiml-smart-core/entities/engagement.prl +323 -0
  419. package/oiml-smart-core/entities/instrument.prl +359 -0
  420. package/oiml-smart-core/entities/module-b.prl +214 -0
  421. package/oiml-smart-core/entities/operated-schemes.prl +141 -0
  422. package/oiml-smart-core/entities/parties.prl +429 -0
  423. package/oiml-smart-core/entities/payment-records.prl +92 -0
  424. package/oiml-smart-core/entities/verification.prl +187 -0
  425. package/oiml-smart-core/entities/workflow.prl +2075 -0
  426. package/oiml-smart-core/evaluation/roles.prl +65 -0
  427. package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
  428. package/oiml-smart-core/package.primmel +10 -0
  429. package/oiml-smart-core/specification/competence-kinds.prl +64 -0
  430. package/oiml-smart-core/specification/constraints.prl +40 -0
  431. package/oiml-smart-core/specification/invariants.prl +90 -0
  432. package/oiml-smart-core/specification/predicates.prl +116 -0
  433. package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
  434. package/oiml-smart-module-env-iec60068/package.primmel +10 -0
  435. package/oiml-smart-module-examination-docs/package.primmel +10 -0
  436. package/oiml-smart-module-reference-materials/package.primmel +10 -0
  437. package/oiml-smart-module-report-headers/package.primmel +10 -0
  438. package/oiml-smart-module-software-d31/package.primmel +10 -0
  439. package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
  440. package/oiml-smart-module-specimen-governance/package.primmel +10 -0
  441. package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
  442. package/oiml-twin-cert/evaluation/roles.prl +15 -0
  443. package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
  444. package/oiml-twin-cert/execution/forms/probe.prl +99 -0
  445. package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
  446. package/oiml-twin-cert/model/attributes.prl +243 -0
  447. package/oiml-twin-cert/model/behaviors.prl +8 -0
  448. package/oiml-twin-cert/model/characteristics.prl +18 -0
  449. package/oiml-twin-cert/model/monitors.prl +16 -0
  450. package/oiml-twin-cert/package.primmel +16 -0
  451. package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
  452. package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
  453. package/oiml-twin-cert/specification/symbols.prl +36 -0
  454. package/oiml-twin-cert/terminology.prl +8 -0
  455. package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
  456. package/package.json +17 -0
  457. package/qms-ref/model/qms.prl +31 -0
  458. package/qms-ref/package.primmel +38 -0
  459. package/quarry-belt-scale/model/ops.prl +115 -0
  460. package/quarry-belt-scale/package.primmel +36 -0
@@ -0,0 +1,308 @@
1
+ term gas-analytical-system {
2
+ label "gas analytical system"
3
+ definition "assembly to carry out specified gas analytical measurements (ISO 7504:2001)"
4
+ section "2.1"
5
+ note "In this Recommendation, a system that continuously measures the volume fraction of CO, NO, NO2, or sum of nitrogen oxides (NOx), or measures only CO or only NO and NO2, or NOx, by analyzing the gas samples taken directly from the smokestack or gas pipe in industry. Includes sampling/sample preparation means (extractive sampling), a gas analyzer, zero/CGM adjustment means, accumulation/processing/storage of results, control and adjustment of main components, an interface for gas flow parameter devices, and gas/electric communication lines."
6
+ source "urn:oiml:pub:r:144-1:2013#clause-2.1"
7
+ language "en"
8
+ form_type "fullForm"
9
+ part_of_speech "noun"
10
+ }
11
+
12
+ term sampling-probe {
13
+ label "sampling probe"
14
+ definition "device inserted into the gas, designed to take a representative sample thereof, to which a sample line or a sample container is connected (ISO 7504:2001)"
15
+ section "2.2"
16
+ source "urn:oiml:pub:r:144-1:2013#clause-2.2"
17
+ language "en"
18
+ form_type "fullForm"
19
+ part_of_speech "noun"
20
+ }
21
+
22
+ term sample-line {
23
+ label "sample line"
24
+ definition "line provided to remove a representative sample of a gas to be analyzed and to transport it to the analyzer (ISO 7504:2001)"
25
+ section "2.3"
26
+ note "A sample line may include devices such as coarse and fine filters, dryers or separators which are necessary to prepare the sample for analysis."
27
+ source "urn:oiml:pub:r:144-1:2013#clause-2.3"
28
+ language "en"
29
+ form_type "fullForm"
30
+ part_of_speech "noun"
31
+ }
32
+
33
+ term gas-analyzer {
34
+ label "gas analyzer"
35
+ definition "assembly which enables qualitative and/or quantitative determinations (measurements) of substances content on the basis of their chemical or physical properties (ISO 7504:2001)"
36
+ section "2.4"
37
+ note "A gas analyzer measures all components covered by this Recommendation (CO, NO, NO2, or NOx), or measures only CO, or only NO and NO2, or NOx."
38
+ source "urn:oiml:pub:r:144-1:2013#clause-2.4"
39
+ language "en"
40
+ form_type "fullForm"
41
+ part_of_speech "noun"
42
+ }
43
+
44
+ term input-measurement-signal {
45
+ label "input measurement signal"
46
+ definition "measurement signal functionally related to the measurand — the volume fraction of a component to be measured, which enters the input of a measuring instrument, a measuring channel or a separate converter component"
47
+ section "2.5"
48
+ source "urn:oiml:pub:r:144-1:2013#clause-2.5"
49
+ language "en"
50
+ form_type "fullForm"
51
+ part_of_speech "noun"
52
+ }
53
+
54
+ term gas-handling-system {
55
+ label "gas handling system"
56
+ definition "all components of the gas analytical system, from the sampling probe to the tube of the gas sample outlet, through which the gas samples, including the Calibration Gas Mixture (CGM) and the zero gas, are conveyed by the pump"
57
+ section "2.6"
58
+ source "urn:oiml:pub:r:144-1:2013#clause-2.6"
59
+ language "en"
60
+ form_type "fullForm"
61
+ part_of_speech "noun"
62
+ }
63
+
64
+ term adjustment {
65
+ label "adjustment"
66
+ definition "set of operations carried out on a measuring system so that it provides prescribed indications corresponding to given values of a quantity to be measured"
67
+ vocab_ref { register vim-2012 clause "3.11" }
68
+ section "2.7"
69
+ source "urn:oiml:pub:v:2-200:2012#clause-3.11"
70
+ language "en"
71
+ form_type "fullForm"
72
+ part_of_speech "noun"
73
+ }
74
+
75
+ term user-adjustment {
76
+ label "user adjustment"
77
+ definition "adjustment employing only the means at the disposal of the user"
78
+ section "2.7.1"
79
+ source "urn:oiml:pub:r:144-1:2013#clause-2.7.1"
80
+ language "en"
81
+ form_type "fullForm"
82
+ part_of_speech "noun"
83
+ }
84
+
85
+ term adjustment-means {
86
+ label "adjustment means"
87
+ definition "means allowing the adjustment of the gas analytical system by the user"
88
+ section "2.7.2"
89
+ source "urn:oiml:pub:r:144-1:2013#clause-2.7.2"
90
+ language "en"
91
+ form_type "fullForm"
92
+ part_of_speech "noun"
93
+ }
94
+
95
+ term semi-automatic-adjustment {
96
+ label "semi-automatic adjustment means"
97
+ definition "means allowing the user to adjust the gas analytical system without having the possibility of changing the input measurement signal, whether the automatic adjustment is required or not"
98
+ section "2.7.3"
99
+ note "For those gas analytical systems that require the calibration gas mixture to be entered manually, the adjustment means are considered to be semi-automatic."
100
+ source "urn:oiml:pub:r:144-1:2013#clause-2.7.3"
101
+ language "en"
102
+ form_type "fullForm"
103
+ part_of_speech "noun"
104
+ }
105
+
106
+ term automatic-adjustment {
107
+ label "automatic adjustment means"
108
+ definition "means which perform the adjustment of the gas analytical system as programmed without the intervention of the user, to initiate the adjustment or regulate the measurement signal"
109
+ section "2.7.4"
110
+ source "urn:oiml:pub:r:144-1:2013#clause-2.7.4"
111
+ language "en"
112
+ form_type "fullForm"
113
+ part_of_speech "noun"
114
+ }
115
+
116
+ term zero-setting-means {
117
+ label "zero-setting means (of a gas analyzer)"
118
+ definition "means to set the indication of the gas analyzer to zero"
119
+ section "2.8"
120
+ source "urn:oiml:pub:r:144-1:2013#clause-2.8"
121
+ language "en"
122
+ form_type "fullForm"
123
+ part_of_speech "noun"
124
+ }
125
+
126
+ term cgm-adjustment-means {
127
+ label "means for adjustment of a gas analyzer by the calibration gas mixture"
128
+ definition "means to adjust the indication of the gas analyzer to the value of the CO, NO and NO2 volume fraction in a CGM"
129
+ section "2.9"
130
+ source "urn:oiml:pub:r:144-1:2013#clause-2.9"
131
+ language "en"
132
+ form_type "fullForm"
133
+ part_of_speech "noun"
134
+ }
135
+
136
+ term internal-adjustment-means {
137
+ label "internal adjustment means"
138
+ definition "means to adjust the gas analyzer without the use of a CGM"
139
+ section "2.10"
140
+ source "urn:oiml:pub:r:144-1:2013#clause-2.10"
141
+ language "en"
142
+ form_type "fullForm"
143
+ part_of_speech "noun"
144
+ }
145
+
146
+ term warm-up-time {
147
+ label "warm-up time"
148
+ definition "period of time that the gas analytical system requires from applying power to the instrument to attaining the operating mode at which the instrument will operate within the maximum permissible errors"
149
+ section "2.11"
150
+ note "For a gas analyzer this is the time between the instant at which power is applied to it and the instant at which the measurement result of the volume fraction, a CGM being supplied to the input, is within the permissible limits."
151
+ source "urn:oiml:pub:r:144-1:2013#clause-2.11"
152
+ language "en"
153
+ form_type "fullForm"
154
+ part_of_speech "noun"
155
+ }
156
+
157
+ term response-time {
158
+ label "response time"
159
+ definition "time interval between the instant of a stepwise concentration change of the component being measured (CO, NO, NO2 or NOx) and the instant at which the signal reaches 90 % of its stable value"
160
+ section "2.12"
161
+ source "urn:oiml:pub:r:144-1:2013#clause-2.12"
162
+ language "en"
163
+ form_type "fullForm"
164
+ part_of_speech "noun"
165
+ }
166
+
167
+ term error {
168
+ label "error"
169
+ definition "measured quantity value minus a reference quantity value"
170
+ vocab_ref { register vim-2012 clause "2.16" }
171
+ section "2.13"
172
+ source "urn:oiml:pub:v:2-200:2012#clause-2.16"
173
+ language "en"
174
+ form_type "fullForm"
175
+ part_of_speech "noun"
176
+ }
177
+
178
+ term intrinsic-error {
179
+ label "intrinsic error"
180
+ definition "error of a gas analyzer, determined under reference conditions"
181
+ section "2.14"
182
+ source "urn:oiml:pub:r:144-1:2013#clause-2.14"
183
+ language "en"
184
+ form_type "fullForm"
185
+ part_of_speech "noun"
186
+ }
187
+
188
+ term relative-error {
189
+ label "relative error"
190
+ definition "absolute error of measurement divided by the reference value of the measurand"
191
+ section "2.15"
192
+ source "urn:oiml:pub:r:144-1:2013#clause-2.15"
193
+ language "en"
194
+ form_type "fullForm"
195
+ part_of_speech "noun"
196
+ }
197
+
198
+ term fault {
199
+ label "fault"
200
+ definition "difference between the error of indication and the intrinsic error of the measuring instrument (OIML V 1:2012, 5.11)"
201
+ section "2.16"
202
+ note "Random errors presenting momentary variations in the indication but which cannot be interpreted, recorded or transmitted as measuring results are considered to be insignificant faults."
203
+ source "urn:oiml:pub:r:144-1:2013#clause-2.16"
204
+ language "en"
205
+ form_type "fullForm"
206
+ part_of_speech "noun"
207
+ }
208
+
209
+ term influence-quantity {
210
+ label "influence quantity"
211
+ definition "quantity that, in a direct measurement, does not affect the quantity that is actually measured, but that affects the relation between the indication and the measurement result"
212
+ vocab_ref { register vim-2012 clause "2.52" }
213
+ section "2.17"
214
+ source "urn:oiml:pub:v:2-200:2012#clause-2.52"
215
+ language "en"
216
+ form_type "fullForm"
217
+ part_of_speech "noun"
218
+ }
219
+
220
+ term rated-operating-conditions {
221
+ label "rated operating conditions"
222
+ definition "operating conditions that must be fulfilled during measurement in order that a measuring instrument or measuring system perform as designed"
223
+ vocab_ref { register vim-2012 clause "4.9" }
224
+ section "2.18"
225
+ source "urn:oiml:pub:v:2-200:2012#clause-4.9"
226
+ language "en"
227
+ form_type "fullForm"
228
+ part_of_speech "noun"
229
+ }
230
+
231
+ term disturbance {
232
+ label "disturbance"
233
+ definition "influence quantity having a value within the limits specified in this Recommendation but outside the specified rated operating conditions of a measuring instrument (OIML V 1:2012, 5.16)"
234
+ section "2.19"
235
+ source "urn:oiml:pub:r:144-1:2013#clause-2.19"
236
+ language "en"
237
+ form_type "fullForm"
238
+ part_of_speech "noun"
239
+ }
240
+
241
+ term reference-condition {
242
+ label "reference condition"
243
+ definition "operating condition prescribed for evaluating the performance of a measuring instrument or measuring system or for comparison of measurement results"
244
+ vocab_ref { register vim-2012 clause "4.11" }
245
+ section "2.20"
246
+ source "urn:oiml:pub:v:2-200:2012#clause-4.11"
247
+ language "en"
248
+ form_type "fullForm"
249
+ part_of_speech "noun"
250
+ }
251
+
252
+ term checking-facility {
253
+ label "checking facility"
254
+ definition "facility that is incorporated in a measuring instrument and which enables significant faults to be detected and acted upon (OIML V 1:2012, 5.06)"
255
+ section "2.21"
256
+ note "\"Acted upon\" refers to any adequate response by the measuring instrument (luminous signal, acoustic signal, prevention of the measurement process, etc.)."
257
+ source "urn:oiml:pub:r:144-1:2013#clause-2.21"
258
+ language "en"
259
+ form_type "fullForm"
260
+ part_of_speech "noun"
261
+ }
262
+
263
+ term gas-sample {
264
+ label "gas sample"
265
+ definition "gas taken from the pipe or gas duct of the stationary source of emissions, conveyed to the gas analyzer for analysis"
266
+ section "2.22"
267
+ source "urn:oiml:pub:r:144-1:2013#clause-2.22"
268
+ language "en"
269
+ form_type "fullForm"
270
+ part_of_speech "noun"
271
+ }
272
+
273
+ term drift {
274
+ label "instrumental drift"
275
+ definition "continuous or incremental change over time in the indication, due to changes in the metrological properties of a measuring instrument"
276
+ vocab_ref { register vim-2012 clause "4.21" }
277
+ section "2.23"
278
+ note "In this Recommendation, \"drift\" means a change in the indication which occurs during a stated period of time at a given concentration of CO, NO and NO2 in a sample to be analyzed."
279
+ source "urn:oiml:pub:v:2-200:2012#clause-4.21"
280
+ language "en"
281
+ form_type "fullForm"
282
+ part_of_speech "noun"
283
+ aliases { drift }
284
+ colloquial { drifting "readings drift over time" }
285
+ }
286
+
287
+ term cgm {
288
+ label "calibration gas mixture"
289
+ definition "stable gas mixture of known concentration (volume fraction) of a component being determined and used for periodic calibration and adjustment of the gas analyzer, as well as for tests of its metrological characteristics for compliance with the requirements of normative documents"
290
+ section "2.24"
291
+ source "urn:oiml:pub:r:144-1:2013#clause-2.24"
292
+ language "en"
293
+ form_type "fullForm"
294
+ part_of_speech "noun"
295
+ abbreviations { CGM }
296
+ }
297
+
298
+ term abbreviations {
299
+ label "abbreviations"
300
+ definition "Abbreviations used in this Recommendation: CGM (Calibration Gas Mixture), IEC, ISO, MPE (Maximum Permissible Error), ppm (part per million, e.g. 1 cm3/1 m3 — ISO 80000-9, SI Brochure 5.3.7), EUT (Equipment Under Test)"
301
+ section "2.25"
302
+ source "urn:oiml:pub:r:144-1:2013#clause-2.25"
303
+ language "en"
304
+ form_type "fullForm"
305
+ part_of_speech "noun"
306
+ see_also { gas-analytical-system cgm intrinsic-error }
307
+ }
308
+
@@ -0,0 +1,49 @@
1
+ quantity_register r144 {
2
+ kind length { dimensions { L 1 } si_unit "m" }
3
+ kind time { dimensions { T 1 } si_unit "s" }
4
+ kind temperature { dimensions { Θ 1 } si_unit "K" }
5
+ kind electric-current { dimensions { I 1 } si_unit "A" }
6
+ kind pressure { dimensions { L -1 M 1 T -2 } si_unit "Pa" }
7
+ kind frequency { dimensions { T -1 } si_unit "Hz" }
8
+ kind voltage { dimensions { I -1 L 2 M 1 T -3 } si_unit "V" }
9
+ kind electrical-resistance { dimensions { I -2 L 2 M 1 T -3 } si_unit "Ω" }
10
+ kind capacitance { dimensions { I 2 L -2 M -1 T 4 } si_unit "F" }
11
+ kind electric-field-strength { dimensions { I -1 L 1 M 1 T -3 } si_unit "V/m" }
12
+ kind magnetic-field-strength { dimensions { I 1 L -1 } si_unit "A/m" }
13
+ kind volume-flow-rate { dimensions { L 3 T -1 } si_unit "m³/s" }
14
+ kind relative-humidity { si_unit "1" }
15
+ kind ratio { si_unit "1" }
16
+ kind volume-fraction { si_unit "1" }
17
+ kind mass-concentration { dimensions { L -3 M 1 } si_unit "kg/m³" }
18
+ kind dimensionless { si_unit "1" }
19
+ unit m { symbol "m" label "metre" kind length }
20
+ unit s { symbol "s" label "second" kind time }
21
+ unit K { symbol "K" label "kelvin" kind temperature }
22
+ unit A { symbol "A" label "ampere" kind electric-current }
23
+ unit Pa { symbol "Pa" label "pascal" kind pressure definition "N/m²" }
24
+ unit Hz { symbol "Hz" label "hertz" kind frequency definition "1/s" }
25
+ unit V { symbol "V" label "volt" kind voltage definition "W/A" }
26
+ unit Ω { symbol "Ω" label "ohm" kind electrical-resistance definition "V/A" }
27
+ unit F { symbol "F" label "farad" kind capacitance definition "C/V" }
28
+ unit degC { symbol "°C" label "degree Celsius" kind temperature offset 273.15 }
29
+ unit min { symbol "min" label "minute" kind time factor 60 }
30
+ unit h { symbol "h" label "hour" kind time factor 3600 }
31
+ unit d { symbol "d" label "day" kind time factor 86400 }
32
+ unit ms { symbol "ms" label "millisecond" kind time factor 0.001 }
33
+ unit ns { symbol "ns" label "nanosecond" kind time factor 1e-9 }
34
+ unit kPa { symbol "kPa" label "kilopascal" kind pressure factor 1000 }
35
+ unit mm { symbol "mm" label "millimetre" kind length factor 0.001 }
36
+ unit kV { symbol "kV" label "kilovolt" kind voltage factor 1000 }
37
+ unit pF { symbol "pF" label "picofarad" kind capacitance factor 1e-12 }
38
+ unit kHz { symbol "kHz" label "kilohertz" kind frequency factor 1000 }
39
+ unit MHz { symbol "MHz" label "megahertz" kind frequency factor 1000000 }
40
+ unit GHz { symbol "GHz" label "gigahertz" kind frequency factor 1000000000 }
41
+ unit V/m { symbol "V/m" label "volt per metre" kind electric-field-strength }
42
+ unit A/m { symbol "A/m" label "ampere per metre" kind magnetic-field-strength }
43
+ unit L/min { symbol "L/min" label "litre per minute" kind volume-flow-rate factor 0.0000166667 }
44
+ unit pctRH { symbol "%RH" label "percent relative humidity" kind relative-humidity factor 0.01 }
45
+ unit % { symbol "%" label "percent" kind ratio factor 0.01 }
46
+ unit ppm { symbol "ppm" label "part per million (volume fraction)" kind volume-fraction factor 0.000001 definition "1 cm³/m³ (ISO 80000-9, 9.15)" }
47
+ unit mg/m3 { symbol "mg/m³" label "milligram per cubic metre" kind mass-concentration factor 0.000001 }
48
+ unit dimensionless { label "dimensionless" kind dimensionless }
49
+ }
@@ -0,0 +1,2 @@
1
+ # .primmel-allowlist.prl — GENERATED from primmel-allowlist.yaml (TODO.roadmap/17), do not edit.
2
+ text_coverage_budget 0 "TODO.roadmap/26 — the R 60 report shows 100% normative-sentence coverage over the four parts (315/315 gated sentences accounted: 292 bound + 23 deliberate exclusions sentence-pinned in sources-prd/coverage.yaml; R 60-4 joined the corpus in the TODO.UPGRADE/25 successor wave). Any new uncovered sentence is a regression and fails (C72)."