This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (460) hide show
  1. package/AGENTS.md +60 -0
  2. package/LICENSE +21 -0
  3. package/README.md +68 -0
  4. package/acme-cgm-200/model/cgm200.prl +284 -0
  5. package/acme-cgm-200/model/r144-map.prl +337 -0
  6. package/acme-cgm-200/package.primmel +39 -0
  7. package/acme-cgm-system/model/cgm-system.prl +125 -0
  8. package/acme-cgm-system/model/r144-map.prl +75 -0
  9. package/acme-cgm-system/model/sample-line.prl +42 -0
  10. package/acme-cgm-system/package.primmel +23 -0
  11. package/acme-lc500/model/lc500.prl +218 -0
  12. package/acme-lc500/model/passport.prl +43 -0
  13. package/acme-lc500/model/r60-map.prl +161 -0
  14. package/acme-lc500/model/twin-cert-map.prl +114 -0
  15. package/acme-lc500/package.primmel +35 -0
  16. package/acme-md3xx/model/md350.prl +317 -0
  17. package/acme-md3xx/model/r129-map.prl +346 -0
  18. package/acme-md3xx/package.primmel +49 -0
  19. package/acme-rs180/model/r91-map.prl +234 -0
  20. package/acme-rs180/model/rs180.prl +236 -0
  21. package/acme-rs180/package.primmel +47 -0
  22. package/ims-demo/model/ims.prl +23 -0
  23. package/ims-demo/model/isms-map.prl +60 -0
  24. package/ims-demo/model/qms-map.prl +73 -0
  25. package/ims-demo/package.primmel +42 -0
  26. package/isms-ref/model/isms.prl +34 -0
  27. package/isms-ref/package.primmel +35 -0
  28. package/iso-iec-17000/package.primmel +8 -0
  29. package/iso-iec-17000/terminology.prl +268 -0
  30. package/iso-iec-17025/package.primmel +10 -0
  31. package/iso-iec-17025/specification/requirements/lab.prl +474 -0
  32. package/iso-iec-17025/terminology.prl +72 -0
  33. package/iso-iec-17065/package.primmel +10 -0
  34. package/iso-iec-17065/specification/requirements/body.prl +446 -0
  35. package/iso-iec-17065/terminology.prl +103 -0
  36. package/iso-iec-17067/package.primmel +10 -0
  37. package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
  38. package/iso-iec-17067/terminology.prl +24 -0
  39. package/oiml-cs/package.primmel +10 -0
  40. package/oiml-cs/specification/discrepancies.prl +26 -0
  41. package/oiml-cs/specification/requirements/cs.prl +515 -0
  42. package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
  43. package/oiml-cs-dataspace/package.primmel +9 -0
  44. package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
  45. package/oiml-cs-dataspace/specification/policies.prl +68 -0
  46. package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
  47. package/oiml-integrated-ref/package.primmel +10 -0
  48. package/oiml-r129/.primmel-allowlist.prl +2 -0
  49. package/oiml-r129/evaluation/processes.prl +152 -0
  50. package/oiml-r129/evaluation/workflow.prl +48 -0
  51. package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
  52. package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
  53. package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
  54. package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
  55. package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
  56. package/oiml-r129/execution/forms/admin/identification.prl +49 -0
  57. package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
  58. package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
  59. package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
  60. package/oiml-r129/execution/forms/emc/esd.prl +66 -0
  61. package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
  62. package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
  63. package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
  64. package/oiml-r129/execution/forms/emc/surge.prl +61 -0
  65. package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
  66. package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
  67. package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
  68. package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
  69. package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
  70. package/oiml-r129/execution/forms/shared/headers.prl +86 -0
  71. package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
  72. package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
  73. package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
  74. package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
  75. package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
  76. package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
  77. package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
  78. package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
  79. package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
  80. package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
  81. package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
  82. package/oiml-r129/layers.prl +50 -0
  83. package/oiml-r129/model/attributes.prl +243 -0
  84. package/oiml-r129/model/behaviors.prl +79 -0
  85. package/oiml-r129/model/capabilities.prl +29 -0
  86. package/oiml-r129/model/characteristics.prl +8 -0
  87. package/oiml-r129/model/conditions.prl +23 -0
  88. package/oiml-r129/model/instrument.prl +67 -0
  89. package/oiml-r129/model/state.prl +22 -0
  90. package/oiml-r129/model/twin.prl +23 -0
  91. package/oiml-r129/package.primmel +15 -0
  92. package/oiml-r129/payload/application.yaml +40 -0
  93. package/oiml-r129/payload/conditions-common-test.yaml +8 -0
  94. package/oiml-r129/payload/formulas-variants.yaml +33 -0
  95. package/oiml-r129/payload/promises.yaml +102 -0
  96. package/oiml-r129/payload/sample-data.yaml +300 -0
  97. package/oiml-r129/references.prl +306 -0
  98. package/oiml-r129/sources-prd/coverage.json +59 -0
  99. package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
  100. package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
  101. package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
  102. package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
  103. package/oiml-r129/specification/calculations.prl +83 -0
  104. package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
  105. package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
  106. package/oiml-r129/specification/conformance/examinations.prl +83 -0
  107. package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
  108. package/oiml-r129/specification/formulas.prl +9 -0
  109. package/oiml-r129/specification/requirements/electronic.prl +46 -0
  110. package/oiml-r129/specification/requirements/metrological.prl +83 -0
  111. package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
  112. package/oiml-r129/specification/requirements/software.prl +57 -0
  113. package/oiml-r129/specification/requirements/technical.prl +134 -0
  114. package/oiml-r129/specification/symbols.prl +187 -0
  115. package/oiml-r129/specification/tables.prl +74 -0
  116. package/oiml-r129/terminology.prl +415 -0
  117. package/oiml-r129/value-types.prl +40 -0
  118. package/oiml-r144/.primmel-allowlist.prl +2 -0
  119. package/oiml-r144/entities/instrument.prl +360 -0
  120. package/oiml-r144/entities/test-execution.prl +228 -0
  121. package/oiml-r144/entities/workflow.prl +2075 -0
  122. package/oiml-r144/evaluation/processes.prl +152 -0
  123. package/oiml-r144/evaluation/workflow.prl +48 -0
  124. package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
  125. package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
  126. package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
  127. package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
  128. package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
  129. package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
  130. package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
  131. package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
  132. package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
  133. package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
  134. package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
  135. package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
  136. package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
  137. package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
  138. package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
  139. package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
  140. package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
  141. package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
  142. package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
  143. package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
  144. package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
  145. package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
  146. package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
  147. package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
  148. package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
  149. package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
  150. package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
  151. package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
  152. package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
  153. package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
  154. package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
  155. package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
  156. package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
  157. package/oiml-r144/execution/forms/shared/headers.prl +132 -0
  158. package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
  159. package/oiml-r144/layers.prl +44 -0
  160. package/oiml-r144/model/attributes.prl +679 -0
  161. package/oiml-r144/model/behaviors.prl +117 -0
  162. package/oiml-r144/model/capabilities.prl +99 -0
  163. package/oiml-r144/model/characteristics.prl +27 -0
  164. package/oiml-r144/model/conditions.prl +46 -0
  165. package/oiml-r144/model/instrument.prl +85 -0
  166. package/oiml-r144/model/state.prl +18 -0
  167. package/oiml-r144/model/twin.prl +25 -0
  168. package/oiml-r144/package.primmel +15 -0
  169. package/oiml-r144/payload/application.yaml +80 -0
  170. package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
  171. package/oiml-r144/payload/conditions-common-test.yaml +74 -0
  172. package/oiml-r144/payload/formulas-variants.yaml +32 -0
  173. package/oiml-r144/payload/promises.yaml +118 -0
  174. package/oiml-r144/payload/sample-data.yaml +643 -0
  175. package/oiml-r144/references.prl +594 -0
  176. package/oiml-r144/sources-prd/coverage.json +114 -0
  177. package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
  178. package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
  179. package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
  180. package/oiml-r144/specification/calculations.prl +123 -0
  181. package/oiml-r144/specification/conformance/examination.prl +87 -0
  182. package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
  183. package/oiml-r144/specification/formulas.prl +37 -0
  184. package/oiml-r144/specification/reference-materials.prl +87 -0
  185. package/oiml-r144/specification/requirements/controls.prl +51 -0
  186. package/oiml-r144/specification/requirements/metrological.prl +299 -0
  187. package/oiml-r144/specification/requirements/report.prl +35 -0
  188. package/oiml-r144/specification/requirements/technical.prl +455 -0
  189. package/oiml-r144/specification/symbols.prl +357 -0
  190. package/oiml-r144/specification/tables.prl +95 -0
  191. package/oiml-r144/specification/test-point-sets.prl +15 -0
  192. package/oiml-r144/terminology.prl +308 -0
  193. package/oiml-r144/value-types.prl +49 -0
  194. package/oiml-r60/.primmel-allowlist.prl +2 -0
  195. package/oiml-r60/entities/workflow.prl +2079 -0
  196. package/oiml-r60/evaluation/processes.prl +152 -0
  197. package/oiml-r60/evaluation/workflow.prl +48 -0
  198. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
  199. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
  200. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
  201. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
  202. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
  203. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
  204. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
  205. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
  206. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
  207. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
  208. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
  209. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
  210. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
  211. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
  212. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
  213. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
  214. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
  215. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
  216. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
  217. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
  218. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
  219. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
  220. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
  221. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
  222. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
  223. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
  224. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
  225. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
  226. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
  227. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
  228. package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
  229. package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
  230. package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
  231. package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
  232. package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
  233. package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
  234. package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
  235. package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
  236. package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
  237. package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
  238. package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
  239. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
  240. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
  241. package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
  242. package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
  243. package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
  244. package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
  245. package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
  246. package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
  247. package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
  248. package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
  249. package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
  250. package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
  251. package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
  252. package/oiml-r60/execution/forms/shared/headers.prl +255 -0
  253. package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
  254. package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
  255. package/oiml-r60/layers.prl +46 -0
  256. package/oiml-r60/model/attributes.prl +642 -0
  257. package/oiml-r60/model/behaviors.prl +165 -0
  258. package/oiml-r60/model/capabilities.prl +57 -0
  259. package/oiml-r60/model/characteristics.prl +27 -0
  260. package/oiml-r60/model/conditions.prl +50 -0
  261. package/oiml-r60/model/instrument.prl +96 -0
  262. package/oiml-r60/model/processes.prl +54 -0
  263. package/oiml-r60/model/state.prl +22 -0
  264. package/oiml-r60/model/twin.prl +16 -0
  265. package/oiml-r60/package.primmel +16 -0
  266. package/oiml-r60/payload/annexes-part4.yaml +122 -0
  267. package/oiml-r60/payload/application.yaml +83 -0
  268. package/oiml-r60/payload/conditions-common-test.yaml +121 -0
  269. package/oiml-r60/payload/formulas-variants.yaml +55 -0
  270. package/oiml-r60/payload/promises.yaml +224 -0
  271. package/oiml-r60/payload/sample-data.yaml +5025 -0
  272. package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
  273. package/oiml-r60/references.prl +549 -0
  274. package/oiml-r60/sources-prd/coverage.json +740 -0
  275. package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
  276. package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
  277. package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
  278. package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
  279. package/oiml-r60/specification/calculations.prl +318 -0
  280. package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
  281. package/oiml-r60/specification/conformance/electronic.prl +483 -0
  282. package/oiml-r60/specification/conformance/examination.prl +183 -0
  283. package/oiml-r60/specification/conformance/metrological.prl +478 -0
  284. package/oiml-r60/specification/constraints.prl +58 -0
  285. package/oiml-r60/specification/formulas-used.prl +43 -0
  286. package/oiml-r60/specification/formulas.prl +20 -0
  287. package/oiml-r60/specification/requirements/class-specific.prl +655 -0
  288. package/oiml-r60/specification/requirements/classification.prl +114 -0
  289. package/oiml-r60/specification/requirements/electronic.prl +222 -0
  290. package/oiml-r60/specification/requirements/metrological.prl +381 -0
  291. package/oiml-r60/specification/requirements/technical.prl +146 -0
  292. package/oiml-r60/specification/symbols.prl +599 -0
  293. package/oiml-r60/specification/tables.prl +182 -0
  294. package/oiml-r60/specification/test-sequences.prl +72 -0
  295. package/oiml-r60/terminology.prl +920 -0
  296. package/oiml-r60/value-types.prl +46 -0
  297. package/oiml-r91/.primmel-allowlist.prl +3 -0
  298. package/oiml-r91/entities/instrument.prl +359 -0
  299. package/oiml-r91/entities/workflow.prl +2075 -0
  300. package/oiml-r91/evaluation/processes.prl +152 -0
  301. package/oiml-r91/evaluation/workflow.prl +48 -0
  302. package/oiml-r91/execution/forms/evidence-file.prl +41 -0
  303. package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
  304. package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
  305. package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
  306. package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
  307. package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
  308. package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
  309. package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
  310. package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
  311. package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
  312. package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
  313. package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
  314. package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
  315. package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
  316. package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
  317. package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
  318. package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
  319. package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
  320. package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
  321. package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
  322. package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
  323. package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
  324. package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
  325. package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
  326. package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
  327. package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
  328. package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
  329. package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
  330. package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
  331. package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
  332. package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
  333. package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
  334. package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
  335. package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
  336. package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
  337. package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
  338. package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
  339. package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
  340. package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
  341. package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
  342. package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
  343. package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
  344. package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
  345. package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
  346. package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
  347. package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
  348. package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
  349. package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
  350. package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
  351. package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
  352. package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
  353. package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
  354. package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
  355. package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
  356. package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
  357. package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
  358. package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
  359. package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
  360. package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
  361. package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
  362. package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
  363. package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
  364. package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
  365. package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
  366. package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
  367. package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
  368. package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
  369. package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
  370. package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
  371. package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
  372. package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
  373. package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
  374. package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
  375. package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
  376. package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
  377. package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
  378. package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
  379. package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
  380. package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
  381. package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
  382. package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
  383. package/oiml-r91/layers.prl +46 -0
  384. package/oiml-r91/model/artifacts.prl +29 -0
  385. package/oiml-r91/model/attributes.prl +698 -0
  386. package/oiml-r91/model/behaviors.prl +142 -0
  387. package/oiml-r91/model/capabilities.prl +88 -0
  388. package/oiml-r91/model/characteristics.prl +27 -0
  389. package/oiml-r91/model/conditions.prl +37 -0
  390. package/oiml-r91/model/instrument.prl +147 -0
  391. package/oiml-r91/model/state.prl +22 -0
  392. package/oiml-r91/model/twin.prl +17 -0
  393. package/oiml-r91/package.primmel +14 -0
  394. package/oiml-r91/payload/application.yaml +201 -0
  395. package/oiml-r91/payload/conditions-common-test.yaml +19 -0
  396. package/oiml-r91/payload/promises.yaml +142 -0
  397. package/oiml-r91/payload/sample-data.yaml +464 -0
  398. package/oiml-r91/references.prl +72 -0
  399. package/oiml-r91/sources-prd/coverage.json +106 -0
  400. package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
  401. package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
  402. package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
  403. package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
  404. package/oiml-r91/specification/calculations.prl +26 -0
  405. package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
  406. package/oiml-r91/specification/conformance/metrological.prl +906 -0
  407. package/oiml-r91/specification/formulas.prl +10 -0
  408. package/oiml-r91/specification/requirements/class-specific.prl +308 -0
  409. package/oiml-r91/specification/requirements/metrological.prl +176 -0
  410. package/oiml-r91/specification/requirements/technical.prl +173 -0
  411. package/oiml-r91/specification/symbols.prl +323 -0
  412. package/oiml-r91/specification/tables.prl +136 -0
  413. package/oiml-r91/terminology.prl +535 -0
  414. package/oiml-r91/value-types.prl +26 -0
  415. package/oiml-smart-core/entities/comments.prl +101 -0
  416. package/oiml-smart-core/entities/cs-operations.prl +492 -0
  417. package/oiml-smart-core/entities/cs-participants.prl +470 -0
  418. package/oiml-smart-core/entities/engagement.prl +323 -0
  419. package/oiml-smart-core/entities/instrument.prl +359 -0
  420. package/oiml-smart-core/entities/module-b.prl +214 -0
  421. package/oiml-smart-core/entities/operated-schemes.prl +141 -0
  422. package/oiml-smart-core/entities/parties.prl +429 -0
  423. package/oiml-smart-core/entities/payment-records.prl +92 -0
  424. package/oiml-smart-core/entities/verification.prl +187 -0
  425. package/oiml-smart-core/entities/workflow.prl +2075 -0
  426. package/oiml-smart-core/evaluation/roles.prl +65 -0
  427. package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
  428. package/oiml-smart-core/package.primmel +10 -0
  429. package/oiml-smart-core/specification/competence-kinds.prl +64 -0
  430. package/oiml-smart-core/specification/constraints.prl +40 -0
  431. package/oiml-smart-core/specification/invariants.prl +90 -0
  432. package/oiml-smart-core/specification/predicates.prl +116 -0
  433. package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
  434. package/oiml-smart-module-env-iec60068/package.primmel +10 -0
  435. package/oiml-smart-module-examination-docs/package.primmel +10 -0
  436. package/oiml-smart-module-reference-materials/package.primmel +10 -0
  437. package/oiml-smart-module-report-headers/package.primmel +10 -0
  438. package/oiml-smart-module-software-d31/package.primmel +10 -0
  439. package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
  440. package/oiml-smart-module-specimen-governance/package.primmel +10 -0
  441. package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
  442. package/oiml-twin-cert/evaluation/roles.prl +15 -0
  443. package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
  444. package/oiml-twin-cert/execution/forms/probe.prl +99 -0
  445. package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
  446. package/oiml-twin-cert/model/attributes.prl +243 -0
  447. package/oiml-twin-cert/model/behaviors.prl +8 -0
  448. package/oiml-twin-cert/model/characteristics.prl +18 -0
  449. package/oiml-twin-cert/model/monitors.prl +16 -0
  450. package/oiml-twin-cert/package.primmel +16 -0
  451. package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
  452. package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
  453. package/oiml-twin-cert/specification/symbols.prl +36 -0
  454. package/oiml-twin-cert/terminology.prl +8 -0
  455. package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
  456. package/package.json +17 -0
  457. package/qms-ref/model/qms.prl +31 -0
  458. package/qms-ref/package.primmel +38 -0
  459. package/quarry-belt-scale/model/ops.prl +115 -0
  460. package/quarry-belt-scale/package.primmel +36 -0
@@ -0,0 +1,48 @@
1
+ form r144-3/test-low-battery {
2
+ name "Low Battery Voltage Test"
3
+ description "Low voltage of internal battery, not connected to the mains power (R 144-2, 1.18)"
4
+ data_class FormInstance#data
5
+ header r144-3/header-b
6
+ conformance_process /conf/performance-tests/low-battery
7
+ section "R 144-2, 1.18"
8
+ requirements { /req/metrological/rated-conditions }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.5.1"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.18"
11
+ applicability {
12
+ power_supply: [battery, ac-and-battery]
13
+ }
14
+ field battery_voltage_min_declared : number {
15
+ description "Manufacturer-specified minimum battery supply voltage"
16
+ unit "V"
17
+ required true
18
+ measurement_method declared
19
+ bind model.parameters.battery_voltage_min
20
+ }
21
+ field measurements_within_limits : array {
22
+ description "Measurements at a supply voltage within the defined limits (date/time, temperature, voltage, functional mode, indications, errors recorded)"
23
+ required true
24
+ subform_ref cgm-point { }
25
+ }
26
+ field cutoff_voltage : number {
27
+ description "Voltage at which the equipment clearly ceases to function properly"
28
+ unit "V"
29
+ required true
30
+ measurement_method direct
31
+ }
32
+ field response_below_limit : text {
33
+ description "Indications, errors and other relevant responses below the limit"
34
+ }
35
+ field within_spec : boolean {
36
+ required true
37
+ measurement_method evaluated
38
+ targets { /req/metrological/rated-conditions }
39
+ true_label "Pass"
40
+ false_label "Fail"
41
+ evaluation { rule "ocl{cutoff_voltage <= battery_voltage_min_declared}" condition "Functions properly down to the declared battery limit" }
42
+ }
43
+ field remarks : text {
44
+
45
+ }
46
+ pass_fail { criteria "The system shall function within the manufacturer specifications down to the declared battery voltage limit and shall give no invalid result below it (R 144-1, 4.5.1)." pass_if "ocl{within_spec}" }
47
+ }
48
+
@@ -0,0 +1,49 @@
1
+ form r144-3/test-power-reduction {
2
+ name "Short Time Power Reduction Test"
3
+ description "AC mains voltage dips, short interruptions and voltage variations (R 144-2, 1.12) — evidence for R 144-3, 3.8 \"Short time power reduction\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-b
6
+ conformance_process /conf/performance-tests/power-reduction
7
+ section "R 144-2, 1.12"
8
+ requirements { /req/metrological/disturbances }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.5.4"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.12"
11
+ field reductions : array {
12
+ description "Applied reductions (100 % × 10 ms; 40 % × 30 ms), 10 repetitions each with ≥ 10 s interval"
13
+ required true
14
+ items { object fields {
15
+ field reduction_pct : number {
16
+ unit "%"
17
+ required true
18
+ }
19
+ field duration_ms : number {
20
+ unit "ms"
21
+ required true
22
+ }
23
+ field repetitions : integer {
24
+ default 10
25
+ }
26
+ } }
27
+ }
28
+ field measurements : array {
29
+ description "Measurements during the test with the CGM of the largest volume fraction"
30
+ required true
31
+ subform_ref cgm-point { }
32
+ }
33
+ field fault_detected : boolean {
34
+ measurement_method direct
35
+ }
36
+ field within_limits_or_detected : boolean {
37
+ required true
38
+ measurement_method evaluated
39
+ targets { /req/metrological/disturbances }
40
+ true_label "Pass"
41
+ false_label "Fail"
42
+ evaluation { rule "ocl{measurements->forAll(m | abs(m.error) <= max(5, 0.10 * abs(m.cgm_reference))) or fault_detected}" condition "|error| <= MPE on verification, or fault detected" }
43
+ }
44
+ field remarks : text {
45
+
46
+ }
47
+ pass_fail { criteria "The error shall lie within the permissible limits, or the failure shall be detected by the checking facility (R 144-1, 4.5.4 b)." pass_if "ocl{within_limits_or_detected}" }
48
+ }
49
+
@@ -0,0 +1,57 @@
1
+ form r144-3/test-power-supply {
2
+ name "Power Supply Variation Test"
3
+ description "Operation within MPE at the extremes of supply voltage (-15 % / +10 %) and frequency (±2 %) (R 144-2, 1.9) — evidence for R 144-3, 3.8 \"AC supply voltage\" / \"Supply frequency\" / \"DC supply voltage\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-a
6
+ conformance_process /conf/performance-tests/power-supply
7
+ section "R 144-2, 1.9"
8
+ requirements { /req/metrological/rated-conditions /req/metrological/mpe-operating }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.5.1"
10
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.3.2"
11
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.9"
12
+ field nominal_voltage : number {
13
+ unit "V"
14
+ required true
15
+ measurement_method declared
16
+ bind model.parameters.supply_voltage
17
+ }
18
+ field nominal_frequency : number {
19
+ unit "Hz"
20
+ measurement_method declared
21
+ bind model.parameters.supply_frequency
22
+ }
23
+ field supply_extremes : array {
24
+ description "Each extreme of voltage (-15 % / +10 %) and frequency (±2 %)"
25
+ required true
26
+ items { object fields {
27
+ field voltage_actual : number {
28
+ unit "V"
29
+ required true
30
+ measurement_method direct
31
+ }
32
+ field frequency_actual : number {
33
+ unit "Hz"
34
+ measurement_method direct
35
+ }
36
+ field measurements : array {
37
+ description "At least two measurements with the CGM of the largest volume fraction"
38
+ required true
39
+ min_items 2
40
+ subform_ref cgm-point { }
41
+ }
42
+ } }
43
+ }
44
+ field within_mpe_operating : boolean {
45
+ required true
46
+ measurement_method evaluated
47
+ targets { /req/metrological/mpe-operating }
48
+ true_label "Pass"
49
+ false_label "Fail"
50
+ evaluation { rule "ocl{supply_extremes->forAll(x | x.measurements->forAll(m | abs(m.error) <= max(5, 0.10 * abs(m.cgm_reference))))}" condition "all |error| <= MPE on verification at all supply extremes" }
51
+ }
52
+ field remarks : text {
53
+
54
+ }
55
+ pass_fail { criteria "The reading shall remain within the MPE on verification (max(5 ppm, 10 %)) at each extreme of the power supply parameters." pass_if "ocl{within_mpe_operating}" }
56
+ }
57
+
@@ -0,0 +1,60 @@
1
+ form r144-3/test-repeatability {
2
+ name "Repeatability Test"
3
+ description "Estimated standard deviation of 20 consecutive measurements per CGM (R 144-2, 1.4) — evidence for R 144-3, 3.8 \"Repeatability\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-a
6
+ conformance_process /conf/performance-tests/repeatability-test
7
+ section "R 144-2, 1.4"
8
+ requirements { /req/metrological/repeatability }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.4"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.4"
11
+ calculation_context { dimensions true tables { repeatability_runs } }
12
+ field repeatability_series : array {
13
+ description "One series per recommended CGM (R 144-2, 1.2)"
14
+ required true
15
+ items { object fields {
16
+ field cgm_reference : number {
17
+ unit "ppm"
18
+ required true
19
+ measurement_method direct
20
+ }
21
+ field readings : array {
22
+ description "20 consecutive indications (n = 20)"
23
+ required true
24
+ measurement_method direct
25
+ items { number unit "ppm" }
26
+ min_items 20
27
+ }
28
+ field mean_indication : number {
29
+ unit "ppm"
30
+ measurement_method derived
31
+ derivation "ocl{readings->average()}"
32
+ }
33
+ field std_deviation : number {
34
+ unit "ppm"
35
+ measurement_method computed
36
+ specification_reference "R 144-2, 1.4"
37
+ calculation repeatabilityStdDev
38
+ calculation_bindings { y_i: readings }
39
+ }
40
+ field std_dev_limit : number {
41
+ unit "ppm"
42
+ measurement_method computed
43
+ specification_reference "R 144-1, 4.4"
44
+ calculation repeatabilityLimit
45
+ calculation_bindings { measured_value: cgm_reference }
46
+ }
47
+ field within_limit : boolean {
48
+ measurement_method evaluated
49
+ true_label "Pass"
50
+ false_label "Fail"
51
+ evaluation { rule "ocl{std_deviation <= std_dev_limit}" condition "s <= MPE / 3" }
52
+ }
53
+ } }
54
+ }
55
+ field remarks : text {
56
+
57
+ }
58
+ pass_fail { criteria "The estimated standard deviation shall not exceed 1/3 of the maximum permissible intrinsic error at each test point." pass_if "ocl{repeatability_series->forAll(s | s.within_limit)}" }
59
+ }
60
+
@@ -0,0 +1,43 @@
1
+ form r144-3/test-response-time {
2
+ name "Response Time Test"
3
+ description "Time to reach 90 % of the stable signal after switching from ambient air to CGM at 90 % of max range (R 144-2, 1.20) — supports R 144-3, 3.7 \"Response time\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-a
6
+ conformance_process /conf/performance-tests/response-time-test
7
+ section "R 144-2, 1.20"
8
+ requirements { /req/metrological/response-time }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.6"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.20"
11
+ ref definition "urn:oiml:pub:r:144-1:2013#clause-2.12"
12
+ field response_time_declared : number {
13
+ description "Declared response time t_90"
14
+ unit "s"
15
+ measurement_method declared
16
+ bind model.parameters.response_time
17
+ }
18
+ field cgm_reference : number {
19
+ description "CGM at 90 % of the maximum value of the measuring range or sub-range, supplied at ambient pressure ±750 Pa"
20
+ unit "ppm"
21
+ required true
22
+ measurement_method direct
23
+ }
24
+ field t90_measured : number {
25
+ description "Time from replacing ambient air with the sample to 90 % of the stable signal"
26
+ unit "s"
27
+ required true
28
+ measurement_method direct
29
+ }
30
+ field within_limit : boolean {
31
+ required true
32
+ measurement_method evaluated
33
+ targets { /req/metrological/response-time }
34
+ true_label "Pass"
35
+ false_label "Fail"
36
+ evaluation { rule "ocl{t90_measured <= 240}" condition "t_90 <= 4 min (240 s)" }
37
+ }
38
+ field remarks : text {
39
+
40
+ }
41
+ pass_fail { criteria "The reading shall reach at least 90 % of the value within four minutes of the abrupt 0 % to 100 % change (R 144-1, 4.6)." pass_if "ocl{within_limit}" }
42
+ }
43
+
@@ -0,0 +1,47 @@
1
+ form r144-3/test-rf-emf {
2
+ name "Radiated RF Electromagnetic Field Test"
3
+ description "Radiated radio frequency electromagnetic fields, 26 MHz–3 GHz at 10 V/m (R 144-2, 1.17) — evidence for R 144-3, 3.8 \"Radio frequency electromagnetic fields\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-b
6
+ conformance_process /conf/performance-tests/rf-emf
7
+ section "R 144-2, 1.17"
8
+ requirements { /req/metrological/disturbances }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.5.4"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.17"
11
+ field frequency_range : string {
12
+ required true
13
+ measurement_method direct
14
+ default "26 MHz – 3 GHz"
15
+ }
16
+ field field_strength : number {
17
+ unit "V/m"
18
+ required true
19
+ measurement_method direct
20
+ default 10
21
+ }
22
+ field modulation : string {
23
+ measurement_method direct
24
+ default "80 % AM, 1 kHz sine"
25
+ }
26
+ field measurements : array {
27
+ description "Measurements during the test with the CGM of the largest volume fraction"
28
+ required true
29
+ subform_ref cgm-point { }
30
+ }
31
+ field fault_detected : boolean {
32
+ measurement_method direct
33
+ }
34
+ field within_limits_or_detected : boolean {
35
+ required true
36
+ measurement_method evaluated
37
+ targets { /req/metrological/disturbances }
38
+ true_label "Pass"
39
+ false_label "Fail"
40
+ evaluation { rule "ocl{measurements->forAll(m | abs(m.error) <= max(5, 0.10 * abs(m.cgm_reference))) or fault_detected}" condition "|error| <= MPE on verification, or fault detected" }
41
+ }
42
+ field remarks : text {
43
+
44
+ }
45
+ pass_fail { criteria "The error shall lie within the permissible limits, or the failure shall be detected by the checking facility (R 144-1, 4.5.4 e)." pass_if "ocl{within_limits_or_detected}" }
46
+ }
47
+
@@ -0,0 +1,50 @@
1
+ form r144-3/test-shock {
2
+ name "Mechanical Shock Test"
3
+ description "Error before/after 25 mm drops on each bottom edge (R 144-2, 1.11.2) — evidence for R 144-3, 3.8 \"Mechanical shocks\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-b
6
+ conformance_process /conf/performance-tests/shock-test
7
+ section "R 144-2, 1.11.2"
8
+ requirements { /req/metrological/disturbances }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.5.4"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.11.2"
11
+ field drop_height_mm : number {
12
+ unit "mm"
13
+ required true
14
+ measurement_method direct
15
+ default 25
16
+ }
17
+ field drops_per_edge : integer {
18
+ description "One fall on each bottom edge"
19
+ required true
20
+ measurement_method direct
21
+ default 1
22
+ }
23
+ field error_before : object {
24
+ description "Error before the test with the CGM of the largest volume fraction"
25
+ required true
26
+ subform_ref cgm-point { }
27
+ }
28
+ field error_after : object {
29
+ description "Error after the test with the CGM of the largest volume fraction"
30
+ required true
31
+ subform_ref cgm-point { }
32
+ }
33
+ field fault_detected : boolean {
34
+ description "Significant fault detected and acted upon by the checking facility"
35
+ measurement_method direct
36
+ }
37
+ field within_limits_or_detected : boolean {
38
+ required true
39
+ measurement_method evaluated
40
+ targets { /req/metrological/disturbances }
41
+ true_label "Pass"
42
+ false_label "Fail"
43
+ evaluation { rule "ocl{(abs(error_after.error) <= max(5, 0.10 * abs(error_after.cgm_reference))) or fault_detected}" condition "|error| <= MPE on verification, or fault detected" }
44
+ }
45
+ field remarks : text {
46
+
47
+ }
48
+ pass_fail { criteria "The error shall lie within the permissible limits, or the failure shall be detected by the checking facility (R 144-1, 4.5.4 a)." pass_if "ocl{within_limits_or_detected}" }
49
+ }
50
+
@@ -0,0 +1,52 @@
1
+ form r144-3/test-surge {
2
+ name "Surge Test (Signal, Data and Control Lines)"
3
+ description "Electrical surges on signal, data and control lines (R 144-2, 1.15)"
4
+ data_class FormInstance#data
5
+ header r144-3/header-b
6
+ conformance_process /conf/performance-tests/surge
7
+ section "R 144-2, 1.15"
8
+ requirements { /req/metrological/disturbances }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.5.4"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.15"
11
+ applicability {
12
+ capabilities: [data-interface]
13
+ }
14
+ field surge_levels : array {
15
+ description "Unbalanced lines 1.0 kV line-to-line / 2.0 kV line-to-earth; balanced lines 2.0 kV line-to-earth"
16
+ required true
17
+ items { object fields {
18
+ field coupling : string {
19
+ required true
20
+ }
21
+ field amplitude_kv : number {
22
+ unit "kV"
23
+ required true
24
+ }
25
+ } }
26
+ }
27
+ field surges_applied : string {
28
+ description "At least three positive and three negative surges"
29
+ required true
30
+ measurement_method direct
31
+ }
32
+ field measurements : array {
33
+ required true
34
+ subform_ref cgm-point { }
35
+ }
36
+ field fault_detected : boolean {
37
+ measurement_method direct
38
+ }
39
+ field within_limits_or_detected : boolean {
40
+ required true
41
+ measurement_method evaluated
42
+ targets { /req/metrological/disturbances }
43
+ true_label "Pass"
44
+ false_label "Fail"
45
+ evaluation { rule "ocl{measurements->forAll(m | abs(m.error) <= max(5, 0.10 * abs(m.cgm_reference))) or fault_detected}" condition "|error| <= MPE on verification, or fault detected" }
46
+ }
47
+ field remarks : text {
48
+
49
+ }
50
+ pass_fail { criteria "The error shall lie within the permissible limits, or the failure shall be detected by the checking facility." pass_if "ocl{within_limits_or_detected}" }
51
+ }
52
+
@@ -0,0 +1,58 @@
1
+ form r144-3/test-vibration {
2
+ name "Mechanical Vibration Test"
3
+ description "Reading variation under random vibration (R 144-2, 1.11.1) — evidence for R 144-3, 3.8 \"Mechanical vibrations\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-a
6
+ conformance_process /conf/performance-tests/vibration-test
7
+ section "R 144-2, 1.11.1"
8
+ requirements { /req/metrological/vibration }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.5.3"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.11.1"
11
+ field vibration_severity_declared : string {
12
+ description "Manufacturer-specified vibration parameters (minimum severity level 1 of OIML D 11:2013, 11.1)"
13
+ required true
14
+ measurement_method declared
15
+ bind model.parameters.vibration_severity
16
+ }
17
+ field cgm_reference : number {
18
+ description "CGM of the largest volume fraction (R 144-2, 1.2)"
19
+ unit "ppm"
20
+ required true
21
+ measurement_method direct
22
+ }
23
+ field reading_at_rest : number {
24
+ unit "ppm"
25
+ required true
26
+ measurement_method direct
27
+ }
28
+ field reading_under_vibration : number {
29
+ unit "ppm"
30
+ required true
31
+ measurement_method direct
32
+ }
33
+ field variation : number {
34
+ unit "ppm"
35
+ measurement_method computed
36
+ calculation indicationVariation
37
+ calculation_bindings { indication_with: reading_under_vibration indication_without: reading_at_rest }
38
+ }
39
+ field variation_limit : number {
40
+ description "Limit of the reading variation given in the operating manual"
41
+ unit "ppm"
42
+ required true
43
+ measurement_method declared
44
+ }
45
+ field within_limit : boolean {
46
+ required true
47
+ measurement_method evaluated
48
+ targets { /req/metrological/vibration }
49
+ true_label "Pass"
50
+ false_label "Fail"
51
+ evaluation { rule "ocl{abs(variation) <= variation_limit}" condition "|Δreading| <= value given in the operating manual" }
52
+ }
53
+ field remarks : text {
54
+
55
+ }
56
+ pass_fail { criteria "The absolute value of the reading variation shall not exceed the value given in the operating manual (R 144-1, 8.4.3)." pass_if "ocl{within_limit}" }
57
+ }
58
+
@@ -0,0 +1,69 @@
1
+ form r144-3/test-warm-up-time {
2
+ name "Warm-up Time Test"
3
+ description "Measurements immediately after warm-up and at 2, 5, 15 min, at reference conditions and 5 °C (R 144-2, 1.19) — supports R 144-3, 3.7 \"Warm-up time\""
4
+ data_class FormInstance#data
5
+ header r144-3/header-a
6
+ conformance_process /conf/performance-tests/warm-up-test
7
+ section "R 144-2, 1.19"
8
+ requirements { /req/metrological/warm-up-time }
9
+ ref requirement "urn:oiml:pub:r:144-1:2013#clause-4.7"
10
+ ref test-procedure "urn:oiml:pub:r:144-2:2013#clause-1.19"
11
+ field warm_up_time_declared : number {
12
+ description "Manufacturer-specified warm-up time (or automatic warm-up lockout)"
13
+ unit "min"
14
+ required true
15
+ measurement_method declared
16
+ bind model.parameters.warm_up_time
17
+ }
18
+ field test_temperatures : array {
19
+ description "Series at reference conditions and at 5 °C"
20
+ required true
21
+ items { object fields {
22
+ field temperature : number {
23
+ unit "degC"
24
+ required true
25
+ measurement_method direct
26
+ }
27
+ field warm_up_series : array {
28
+ description "Measurements immediately after warm-up, +2 min, +5 min, +15 min, with each CGM"
29
+ required true
30
+ items { object fields {
31
+ field elapsed_min : number {
32
+ description "Time after warm-up (0, 2, 5, 15)"
33
+ unit "min"
34
+ required true
35
+ }
36
+ field cgm_reference : number {
37
+ unit "ppm"
38
+ required true
39
+ }
40
+ field indication : number {
41
+ unit "ppm"
42
+ required true
43
+ measurement_method direct
44
+ }
45
+ } }
46
+ min_items 4
47
+ series { axis elapsed_min { unit "min" role time } axis cgm_reference { unit "ppm" } cell { symbol indication unit "ppm" } }
48
+ }
49
+ } }
50
+ }
51
+ field mpe_basis : string {
52
+ measurement_method declared
53
+ specification_reference "R 144-1, 4.3.2"
54
+ default "max(5 ppm, 10 % of measured value) — MPE on initial verification (R 144-1, 4.3.2)"
55
+ }
56
+ field within_mpe_verification : boolean {
57
+ required true
58
+ measurement_method evaluated
59
+ targets { /req/metrological/warm-up-time }
60
+ true_label "Pass"
61
+ false_label "Fail"
62
+ evaluation { rule "ocl{test_temperatures->forAll(t | group_by(t.warm_up_series, 'cgm_reference')->forAll(g | pairwise_max_difference(g, 'indication') <= max(5, 0.10 * abs(g->first().cgm_reference))))}" condition "Difference between any of the four values <= |MPE on initial verification|" specification_reference "R 144-2, 1.19" }
63
+ }
64
+ field remarks : text {
65
+
66
+ }
67
+ pass_fail { criteria "The difference between any of the four measured values (0, 2, 5, 15 min after warm-up) shall not exceed the absolute value of the maximum permissible error on initial verification (R 144-1, 4.3.2)." pass_if "ocl{within_mpe_verification}" }
68
+ }
69
+
@@ -0,0 +1,132 @@
1
+ form r144-3/header-a {
2
+ name "Form Header A"
3
+ description "Header for gas analytical system test forms with full identification and test conditions"
4
+ data_class FormInstance#data
5
+ field application_no : string {
6
+ required true
7
+ bind application.application_number
8
+ }
9
+ field system_model : string {
10
+ required true
11
+ bind model.model_designation
12
+ }
13
+ field serial_no : string {
14
+ required true
15
+ bind sample.serial_number
16
+ }
17
+ field measurand_components : string {
18
+ required true
19
+ bind model.classification.measurand_components
20
+ }
21
+ field measuring_principle : string {
22
+ bind family.classification.measuring_principle
23
+ }
24
+ field component_under_test : enum {
25
+ required true
26
+ enum_values { CO NO NO2 NOx }
27
+ }
28
+ field range_min : number {
29
+ unit "ppm"
30
+ required true
31
+ }
32
+ field range_max : number {
33
+ unit "ppm"
34
+ required true
35
+ }
36
+ field evaluator : string {
37
+ required true
38
+ }
39
+ field conditions : object {
40
+ fields {
41
+ field date_start : date {
42
+
43
+ }
44
+ field date_end : date {
45
+
46
+ }
47
+ field temperature_start : number {
48
+ unit "degC"
49
+ }
50
+ field temperature_end : number {
51
+ unit "degC"
52
+ }
53
+ field relative_humidity_start : number {
54
+ unit "%"
55
+ }
56
+ field relative_humidity_end : number {
57
+ unit "%"
58
+ }
59
+ field barometric_pressure_start : number {
60
+ unit "kPa"
61
+ }
62
+ field barometric_pressure_end : number {
63
+ unit "kPa"
64
+ }
65
+ }
66
+ }
67
+ }
68
+
69
+
70
+ form r144-3/header-b {
71
+ name "Form Header B"
72
+ description "Compact header for disturbance/EMC test forms"
73
+ data_class FormInstance#data
74
+ field application_no : string {
75
+ required true
76
+ bind application.application_number
77
+ }
78
+ field system_model : string {
79
+ required true
80
+ bind model.model_designation
81
+ }
82
+ field serial_no : string {
83
+ required true
84
+ bind sample.serial_number
85
+ }
86
+ field date : date {
87
+ required true
88
+ }
89
+ field time : string {
90
+ pattern "\\d{2}:\\d{2}:\\d{2}"
91
+ }
92
+ field temperature : number {
93
+ unit "degC"
94
+ }
95
+ field relative_humidity : number {
96
+ unit "%"
97
+ }
98
+ field barometric_pressure : number {
99
+ unit "kPa"
100
+ }
101
+ }
102
+
103
+
104
+ form r144-3/conditions {
105
+ name "Form Conditions"
106
+ description "Conditions block used in most test forms"
107
+ field date_start : date {
108
+
109
+ }
110
+ field date_end : date {
111
+
112
+ }
113
+ field temperature_start : number {
114
+ unit "degC"
115
+ }
116
+ field temperature_end : number {
117
+ unit "degC"
118
+ }
119
+ field relative_humidity_start : number {
120
+ unit "%"
121
+ }
122
+ field relative_humidity_end : number {
123
+ unit "%"
124
+ }
125
+ field barometric_pressure_start : number {
126
+ unit "kPa"
127
+ }
128
+ field barometric_pressure_end : number {
129
+ unit "kPa"
130
+ }
131
+ }
132
+