@oimlsmart/primmel-packages 0.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (460) hide show
  1. package/AGENTS.md +60 -0
  2. package/LICENSE +21 -0
  3. package/README.md +68 -0
  4. package/acme-cgm-200/model/cgm200.prl +284 -0
  5. package/acme-cgm-200/model/r144-map.prl +337 -0
  6. package/acme-cgm-200/package.primmel +39 -0
  7. package/acme-cgm-system/model/cgm-system.prl +125 -0
  8. package/acme-cgm-system/model/r144-map.prl +75 -0
  9. package/acme-cgm-system/model/sample-line.prl +42 -0
  10. package/acme-cgm-system/package.primmel +23 -0
  11. package/acme-lc500/model/lc500.prl +218 -0
  12. package/acme-lc500/model/passport.prl +43 -0
  13. package/acme-lc500/model/r60-map.prl +161 -0
  14. package/acme-lc500/model/twin-cert-map.prl +114 -0
  15. package/acme-lc500/package.primmel +35 -0
  16. package/acme-md3xx/model/md350.prl +317 -0
  17. package/acme-md3xx/model/r129-map.prl +346 -0
  18. package/acme-md3xx/package.primmel +49 -0
  19. package/acme-rs180/model/r91-map.prl +234 -0
  20. package/acme-rs180/model/rs180.prl +236 -0
  21. package/acme-rs180/package.primmel +47 -0
  22. package/ims-demo/model/ims.prl +23 -0
  23. package/ims-demo/model/isms-map.prl +60 -0
  24. package/ims-demo/model/qms-map.prl +73 -0
  25. package/ims-demo/package.primmel +42 -0
  26. package/isms-ref/model/isms.prl +34 -0
  27. package/isms-ref/package.primmel +35 -0
  28. package/iso-iec-17000/package.primmel +8 -0
  29. package/iso-iec-17000/terminology.prl +268 -0
  30. package/iso-iec-17025/package.primmel +10 -0
  31. package/iso-iec-17025/specification/requirements/lab.prl +474 -0
  32. package/iso-iec-17025/terminology.prl +72 -0
  33. package/iso-iec-17065/package.primmel +10 -0
  34. package/iso-iec-17065/specification/requirements/body.prl +446 -0
  35. package/iso-iec-17065/terminology.prl +103 -0
  36. package/iso-iec-17067/package.primmel +10 -0
  37. package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
  38. package/iso-iec-17067/terminology.prl +24 -0
  39. package/oiml-cs/package.primmel +10 -0
  40. package/oiml-cs/specification/discrepancies.prl +26 -0
  41. package/oiml-cs/specification/requirements/cs.prl +515 -0
  42. package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
  43. package/oiml-cs-dataspace/package.primmel +9 -0
  44. package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
  45. package/oiml-cs-dataspace/specification/policies.prl +68 -0
  46. package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
  47. package/oiml-integrated-ref/package.primmel +10 -0
  48. package/oiml-r129/.primmel-allowlist.prl +2 -0
  49. package/oiml-r129/evaluation/processes.prl +152 -0
  50. package/oiml-r129/evaluation/workflow.prl +48 -0
  51. package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
  52. package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
  53. package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
  54. package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
  55. package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
  56. package/oiml-r129/execution/forms/admin/identification.prl +49 -0
  57. package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
  58. package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
  59. package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
  60. package/oiml-r129/execution/forms/emc/esd.prl +66 -0
  61. package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
  62. package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
  63. package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
  64. package/oiml-r129/execution/forms/emc/surge.prl +61 -0
  65. package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
  66. package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
  67. package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
  68. package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
  69. package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
  70. package/oiml-r129/execution/forms/shared/headers.prl +86 -0
  71. package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
  72. package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
  73. package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
  74. package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
  75. package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
  76. package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
  77. package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
  78. package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
  79. package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
  80. package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
  81. package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
  82. package/oiml-r129/layers.prl +50 -0
  83. package/oiml-r129/model/attributes.prl +243 -0
  84. package/oiml-r129/model/behaviors.prl +79 -0
  85. package/oiml-r129/model/capabilities.prl +29 -0
  86. package/oiml-r129/model/characteristics.prl +8 -0
  87. package/oiml-r129/model/conditions.prl +23 -0
  88. package/oiml-r129/model/instrument.prl +67 -0
  89. package/oiml-r129/model/state.prl +22 -0
  90. package/oiml-r129/model/twin.prl +23 -0
  91. package/oiml-r129/package.primmel +15 -0
  92. package/oiml-r129/payload/application.yaml +40 -0
  93. package/oiml-r129/payload/conditions-common-test.yaml +8 -0
  94. package/oiml-r129/payload/formulas-variants.yaml +33 -0
  95. package/oiml-r129/payload/promises.yaml +102 -0
  96. package/oiml-r129/payload/sample-data.yaml +300 -0
  97. package/oiml-r129/references.prl +306 -0
  98. package/oiml-r129/sources-prd/coverage.json +59 -0
  99. package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
  100. package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
  101. package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
  102. package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
  103. package/oiml-r129/specification/calculations.prl +83 -0
  104. package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
  105. package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
  106. package/oiml-r129/specification/conformance/examinations.prl +83 -0
  107. package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
  108. package/oiml-r129/specification/formulas.prl +9 -0
  109. package/oiml-r129/specification/requirements/electronic.prl +46 -0
  110. package/oiml-r129/specification/requirements/metrological.prl +83 -0
  111. package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
  112. package/oiml-r129/specification/requirements/software.prl +57 -0
  113. package/oiml-r129/specification/requirements/technical.prl +134 -0
  114. package/oiml-r129/specification/symbols.prl +187 -0
  115. package/oiml-r129/specification/tables.prl +74 -0
  116. package/oiml-r129/terminology.prl +415 -0
  117. package/oiml-r129/value-types.prl +40 -0
  118. package/oiml-r144/.primmel-allowlist.prl +2 -0
  119. package/oiml-r144/entities/instrument.prl +360 -0
  120. package/oiml-r144/entities/test-execution.prl +228 -0
  121. package/oiml-r144/entities/workflow.prl +2075 -0
  122. package/oiml-r144/evaluation/processes.prl +152 -0
  123. package/oiml-r144/evaluation/workflow.prl +48 -0
  124. package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
  125. package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
  126. package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
  127. package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
  128. package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
  129. package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
  130. package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
  131. package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
  132. package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
  133. package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
  134. package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
  135. package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
  136. package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
  137. package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
  138. package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
  139. package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
  140. package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
  141. package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
  142. package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
  143. package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
  144. package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
  145. package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
  146. package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
  147. package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
  148. package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
  149. package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
  150. package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
  151. package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
  152. package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
  153. package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
  154. package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
  155. package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
  156. package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
  157. package/oiml-r144/execution/forms/shared/headers.prl +132 -0
  158. package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
  159. package/oiml-r144/layers.prl +44 -0
  160. package/oiml-r144/model/attributes.prl +679 -0
  161. package/oiml-r144/model/behaviors.prl +117 -0
  162. package/oiml-r144/model/capabilities.prl +99 -0
  163. package/oiml-r144/model/characteristics.prl +27 -0
  164. package/oiml-r144/model/conditions.prl +46 -0
  165. package/oiml-r144/model/instrument.prl +85 -0
  166. package/oiml-r144/model/state.prl +18 -0
  167. package/oiml-r144/model/twin.prl +25 -0
  168. package/oiml-r144/package.primmel +15 -0
  169. package/oiml-r144/payload/application.yaml +80 -0
  170. package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
  171. package/oiml-r144/payload/conditions-common-test.yaml +74 -0
  172. package/oiml-r144/payload/formulas-variants.yaml +32 -0
  173. package/oiml-r144/payload/promises.yaml +118 -0
  174. package/oiml-r144/payload/sample-data.yaml +643 -0
  175. package/oiml-r144/references.prl +594 -0
  176. package/oiml-r144/sources-prd/coverage.json +114 -0
  177. package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
  178. package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
  179. package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
  180. package/oiml-r144/specification/calculations.prl +123 -0
  181. package/oiml-r144/specification/conformance/examination.prl +87 -0
  182. package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
  183. package/oiml-r144/specification/formulas.prl +37 -0
  184. package/oiml-r144/specification/reference-materials.prl +87 -0
  185. package/oiml-r144/specification/requirements/controls.prl +51 -0
  186. package/oiml-r144/specification/requirements/metrological.prl +299 -0
  187. package/oiml-r144/specification/requirements/report.prl +35 -0
  188. package/oiml-r144/specification/requirements/technical.prl +455 -0
  189. package/oiml-r144/specification/symbols.prl +357 -0
  190. package/oiml-r144/specification/tables.prl +95 -0
  191. package/oiml-r144/specification/test-point-sets.prl +15 -0
  192. package/oiml-r144/terminology.prl +308 -0
  193. package/oiml-r144/value-types.prl +49 -0
  194. package/oiml-r60/.primmel-allowlist.prl +2 -0
  195. package/oiml-r60/entities/workflow.prl +2079 -0
  196. package/oiml-r60/evaluation/processes.prl +152 -0
  197. package/oiml-r60/evaluation/workflow.prl +48 -0
  198. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
  199. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
  200. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
  201. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
  202. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
  203. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
  204. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
  205. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
  206. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
  207. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
  208. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
  209. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
  210. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
  211. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
  212. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
  213. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
  214. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
  215. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
  216. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
  217. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
  218. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
  219. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
  220. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
  221. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
  222. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
  223. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
  224. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
  225. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
  226. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
  227. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
  228. package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
  229. package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
  230. package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
  231. package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
  232. package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
  233. package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
  234. package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
  235. package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
  236. package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
  237. package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
  238. package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
  239. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
  240. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
  241. package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
  242. package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
  243. package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
  244. package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
  245. package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
  246. package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
  247. package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
  248. package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
  249. package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
  250. package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
  251. package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
  252. package/oiml-r60/execution/forms/shared/headers.prl +255 -0
  253. package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
  254. package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
  255. package/oiml-r60/layers.prl +46 -0
  256. package/oiml-r60/model/attributes.prl +642 -0
  257. package/oiml-r60/model/behaviors.prl +165 -0
  258. package/oiml-r60/model/capabilities.prl +57 -0
  259. package/oiml-r60/model/characteristics.prl +27 -0
  260. package/oiml-r60/model/conditions.prl +50 -0
  261. package/oiml-r60/model/instrument.prl +96 -0
  262. package/oiml-r60/model/processes.prl +54 -0
  263. package/oiml-r60/model/state.prl +22 -0
  264. package/oiml-r60/model/twin.prl +16 -0
  265. package/oiml-r60/package.primmel +16 -0
  266. package/oiml-r60/payload/annexes-part4.yaml +122 -0
  267. package/oiml-r60/payload/application.yaml +83 -0
  268. package/oiml-r60/payload/conditions-common-test.yaml +121 -0
  269. package/oiml-r60/payload/formulas-variants.yaml +55 -0
  270. package/oiml-r60/payload/promises.yaml +224 -0
  271. package/oiml-r60/payload/sample-data.yaml +5025 -0
  272. package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
  273. package/oiml-r60/references.prl +549 -0
  274. package/oiml-r60/sources-prd/coverage.json +740 -0
  275. package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
  276. package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
  277. package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
  278. package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
  279. package/oiml-r60/specification/calculations.prl +318 -0
  280. package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
  281. package/oiml-r60/specification/conformance/electronic.prl +483 -0
  282. package/oiml-r60/specification/conformance/examination.prl +183 -0
  283. package/oiml-r60/specification/conformance/metrological.prl +478 -0
  284. package/oiml-r60/specification/constraints.prl +58 -0
  285. package/oiml-r60/specification/formulas-used.prl +43 -0
  286. package/oiml-r60/specification/formulas.prl +20 -0
  287. package/oiml-r60/specification/requirements/class-specific.prl +655 -0
  288. package/oiml-r60/specification/requirements/classification.prl +114 -0
  289. package/oiml-r60/specification/requirements/electronic.prl +222 -0
  290. package/oiml-r60/specification/requirements/metrological.prl +381 -0
  291. package/oiml-r60/specification/requirements/technical.prl +146 -0
  292. package/oiml-r60/specification/symbols.prl +599 -0
  293. package/oiml-r60/specification/tables.prl +182 -0
  294. package/oiml-r60/specification/test-sequences.prl +72 -0
  295. package/oiml-r60/terminology.prl +920 -0
  296. package/oiml-r60/value-types.prl +46 -0
  297. package/oiml-r91/.primmel-allowlist.prl +3 -0
  298. package/oiml-r91/entities/instrument.prl +359 -0
  299. package/oiml-r91/entities/workflow.prl +2075 -0
  300. package/oiml-r91/evaluation/processes.prl +152 -0
  301. package/oiml-r91/evaluation/workflow.prl +48 -0
  302. package/oiml-r91/execution/forms/evidence-file.prl +41 -0
  303. package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
  304. package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
  305. package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
  306. package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
  307. package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
  308. package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
  309. package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
  310. package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
  311. package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
  312. package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
  313. package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
  314. package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
  315. package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
  316. package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
  317. package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
  318. package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
  319. package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
  320. package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
  321. package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
  322. package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
  323. package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
  324. package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
  325. package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
  326. package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
  327. package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
  328. package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
  329. package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
  330. package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
  331. package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
  332. package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
  333. package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
  334. package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
  335. package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
  336. package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
  337. package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
  338. package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
  339. package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
  340. package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
  341. package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
  342. package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
  343. package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
  344. package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
  345. package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
  346. package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
  347. package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
  348. package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
  349. package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
  350. package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
  351. package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
  352. package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
  353. package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
  354. package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
  355. package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
  356. package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
  357. package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
  358. package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
  359. package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
  360. package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
  361. package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
  362. package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
  363. package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
  364. package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
  365. package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
  366. package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
  367. package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
  368. package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
  369. package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
  370. package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
  371. package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
  372. package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
  373. package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
  374. package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
  375. package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
  376. package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
  377. package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
  378. package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
  379. package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
  380. package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
  381. package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
  382. package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
  383. package/oiml-r91/layers.prl +46 -0
  384. package/oiml-r91/model/artifacts.prl +29 -0
  385. package/oiml-r91/model/attributes.prl +698 -0
  386. package/oiml-r91/model/behaviors.prl +142 -0
  387. package/oiml-r91/model/capabilities.prl +88 -0
  388. package/oiml-r91/model/characteristics.prl +27 -0
  389. package/oiml-r91/model/conditions.prl +37 -0
  390. package/oiml-r91/model/instrument.prl +147 -0
  391. package/oiml-r91/model/state.prl +22 -0
  392. package/oiml-r91/model/twin.prl +17 -0
  393. package/oiml-r91/package.primmel +14 -0
  394. package/oiml-r91/payload/application.yaml +201 -0
  395. package/oiml-r91/payload/conditions-common-test.yaml +19 -0
  396. package/oiml-r91/payload/promises.yaml +142 -0
  397. package/oiml-r91/payload/sample-data.yaml +464 -0
  398. package/oiml-r91/references.prl +72 -0
  399. package/oiml-r91/sources-prd/coverage.json +106 -0
  400. package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
  401. package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
  402. package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
  403. package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
  404. package/oiml-r91/specification/calculations.prl +26 -0
  405. package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
  406. package/oiml-r91/specification/conformance/metrological.prl +906 -0
  407. package/oiml-r91/specification/formulas.prl +10 -0
  408. package/oiml-r91/specification/requirements/class-specific.prl +308 -0
  409. package/oiml-r91/specification/requirements/metrological.prl +176 -0
  410. package/oiml-r91/specification/requirements/technical.prl +173 -0
  411. package/oiml-r91/specification/symbols.prl +323 -0
  412. package/oiml-r91/specification/tables.prl +136 -0
  413. package/oiml-r91/terminology.prl +535 -0
  414. package/oiml-r91/value-types.prl +26 -0
  415. package/oiml-smart-core/entities/comments.prl +101 -0
  416. package/oiml-smart-core/entities/cs-operations.prl +492 -0
  417. package/oiml-smart-core/entities/cs-participants.prl +470 -0
  418. package/oiml-smart-core/entities/engagement.prl +323 -0
  419. package/oiml-smart-core/entities/instrument.prl +359 -0
  420. package/oiml-smart-core/entities/module-b.prl +214 -0
  421. package/oiml-smart-core/entities/operated-schemes.prl +141 -0
  422. package/oiml-smart-core/entities/parties.prl +429 -0
  423. package/oiml-smart-core/entities/payment-records.prl +92 -0
  424. package/oiml-smart-core/entities/verification.prl +187 -0
  425. package/oiml-smart-core/entities/workflow.prl +2075 -0
  426. package/oiml-smart-core/evaluation/roles.prl +65 -0
  427. package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
  428. package/oiml-smart-core/package.primmel +10 -0
  429. package/oiml-smart-core/specification/competence-kinds.prl +64 -0
  430. package/oiml-smart-core/specification/constraints.prl +40 -0
  431. package/oiml-smart-core/specification/invariants.prl +90 -0
  432. package/oiml-smart-core/specification/predicates.prl +116 -0
  433. package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
  434. package/oiml-smart-module-env-iec60068/package.primmel +10 -0
  435. package/oiml-smart-module-examination-docs/package.primmel +10 -0
  436. package/oiml-smart-module-reference-materials/package.primmel +10 -0
  437. package/oiml-smart-module-report-headers/package.primmel +10 -0
  438. package/oiml-smart-module-software-d31/package.primmel +10 -0
  439. package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
  440. package/oiml-smart-module-specimen-governance/package.primmel +10 -0
  441. package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
  442. package/oiml-twin-cert/evaluation/roles.prl +15 -0
  443. package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
  444. package/oiml-twin-cert/execution/forms/probe.prl +99 -0
  445. package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
  446. package/oiml-twin-cert/model/attributes.prl +243 -0
  447. package/oiml-twin-cert/model/behaviors.prl +8 -0
  448. package/oiml-twin-cert/model/characteristics.prl +18 -0
  449. package/oiml-twin-cert/model/monitors.prl +16 -0
  450. package/oiml-twin-cert/package.primmel +16 -0
  451. package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
  452. package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
  453. package/oiml-twin-cert/specification/symbols.prl +36 -0
  454. package/oiml-twin-cert/terminology.prl +8 -0
  455. package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
  456. package/package.json +17 -0
  457. package/qms-ref/model/qms.prl +31 -0
  458. package/qms-ref/package.primmel +38 -0
  459. package/quarry-belt-scale/model/ops.prl +115 -0
  460. package/quarry-belt-scale/package.primmel +36 -0
@@ -0,0 +1,317 @@
1
+ # ─────────────────────────────────────────────────────────────────────
2
+ # ACME MD-350 — the product model (TODO.v2/08's R 129 leg; TODO.roadmap/
3
+ # 36; doctrine ch. 15 §15.2; the acme-lc500/acme-rs180 pattern). ***
4
+ # FICTIONAL DEMO PRODUCT. *** A manufacturer authors their product model
5
+ # exactly as any subject model — the full IS/HAS/DOES anatomy:
6
+ # IS design parameters, the classification values stated on R 129's
7
+ # category axes (measurement principle, instrument category,
8
+ # power supply, object capability — R 129-2, Annex A, Table A.1),
9
+ # promises, the endpoint declaration, metadata, provenance (the
10
+ # type-evaluation certificate — the promises-as-verified
11
+ # provenance, §15.2);
12
+ # HAS exhibited attributes (the per-axis indications, the reference
13
+ # dimensions, the calculated quantities), the characteristics the
14
+ # standard's tests compute, the operational state, the serve
15
+ # bindings;
16
+ # DOES the optical scanning behavior, the influence responses (speed,
17
+ # temperature, ambient light), the warm-up and the self-test
18
+ # (the checking facility, R 129-1, 5.6).
19
+ #
20
+ # The MD-350 is an optical, automatic, AC-mains conveyor dimensioner
21
+ # for freight terminals: a light-section scanning frame over the
22
+ # conveyor measures the length, width and height of the smallest
23
+ # enclosing rectangular box of each object in relative movement
24
+ # (R 129-1, 2.1.8 automatic; 2.1.10/2.1.11 V_max/V_min), computes the
25
+ # dimensional volume and the dimensional weight (DW = DV / F,
26
+ # R 129-1, 2.2.4/2.2.7 with the factor of 2.2.8), and serves all of it
27
+ # over its twin endpoint.
28
+ # Irregular-shaped objects are allowed (R 129-1, 5.3 — the instrument
29
+ # is NOT marked rectangular-only).
30
+ #
31
+ # Quantity-typed design parameters carry their literal as the qualifier
32
+ # string "<value> <unit>" — the design-time vocabulary a consumer's
33
+ # abstract import validates against (§15.3 mode 1, computed by the
34
+ # platform's product-coverage gate). The parameter ids are R 129's own
35
+ # vocabulary (d, Min/Max per axis, V_min/V_max, F, T_min/T_max, U_nom):
36
+ # "our x is your x" is the mapping's whole point.
37
+ # ─────────────────────────────────────────────────────────────────────
38
+
39
+ quantity_register si {
40
+ kind length { dimensions { L 1 } si_unit m description "Length of one axis of the object's smallest enclosing rectangular box." }
41
+ unit m { symbol "m" label "metre" kind length factor 1 }
42
+ unit cm { symbol "cm" label "centimetre" kind length factor 0.01 }
43
+ unit d { symbol "d" label "scale interval (d = 0.5 cm on the MD-350)" kind length factor 0.005 }
44
+ kind volume { dimensions { L 3 } si_unit "m³" description "Dimensional volume of the object's smallest enclosing rectangular box." }
45
+ unit cm3 { symbol "cm³" label "cubic centimetre" kind volume factor 0.000001 }
46
+ kind mass { dimensions { M 1 } si_unit kg description "Dimensional weight (DW = DV / F)." }
47
+ unit kg { symbol "kg" label "kilogram" kind mass factor 1 }
48
+ kind speed { dimensions { L 1 T -1 } si_unit "m/s" description "Speed of relative movement between object and instrument (the conveyor speed)." }
49
+ unit m/s { symbol "m/s" label "metre per second" kind speed factor 1 }
50
+ kind temperature { dimensions { Θ 1 } si_unit K description "Temperature." }
51
+ unit degC { symbol "°C" label "degree Celsius" kind temperature offset 273.15 }
52
+ kind voltage { dimensions { I -1 L 2 M 1 T -3 } si_unit V description "Electric voltage." }
53
+ unit V { symbol "V" label "volt" kind voltage factor 1 }
54
+ kind illuminance { si_unit lx description "Illuminance of the ambient light on the measuring area." }
55
+ unit lx { symbol "lx" label "lux" kind illuminance factor 1 }
56
+ kind volume-per-mass { dimensions { L 3 M -1 } si_unit "m³/kg" description "Conversion factor kind — dimensional volume per unit mass (DW = DV / F, R 129-1, 2.2.8)." }
57
+ unit cm3/kg { symbol "cm³/kg" label "cubic centimetre per kilogram" kind volume-per-mass factor 0.000001 }
58
+ kind dimensionless { si_unit "1" }
59
+ unit dimensionless { label "dimensionless" kind dimensionless }
60
+ }
61
+
62
+ attribute_definition indication_length {
63
+ symbol "L"
64
+ name "Indicated length"
65
+ definition "The indicated length of the object's smallest enclosing rectangular box (along the conveyor), rounded to the scale interval d — the served live reading (the product's answer to R 129-1, 2.2.3/5.2.1)."
66
+ quantity_kind length
67
+ unit cm
68
+ value_type QuantityValue
69
+ origin measured
70
+ scope sample
71
+ category metrological
72
+ }
73
+
74
+ attribute_definition indication_width {
75
+ symbol "W"
76
+ name "Indicated width"
77
+ definition "The indicated width of the object's smallest enclosing rectangular box (across the conveyor), rounded to the scale interval d — the served live reading (R 129-1, 2.2.3)."
78
+ quantity_kind length
79
+ unit cm
80
+ value_type QuantityValue
81
+ origin measured
82
+ scope sample
83
+ category metrological
84
+ }
85
+
86
+ attribute_definition indication_height {
87
+ symbol "H"
88
+ name "Indicated height"
89
+ definition "The indicated height of the object's smallest enclosing rectangular box (vertical), rounded to the scale interval d — the served live reading (R 129-1, 2.2.3)."
90
+ quantity_kind length
91
+ unit cm
92
+ value_type QuantityValue
93
+ origin measured
94
+ scope sample
95
+ category metrological
96
+ }
97
+
98
+ attribute_definition dim_volume {
99
+ symbol "DV"
100
+ name "Dimensional volume"
101
+ definition "The dimensional volume, derived from the indicated measured dimensions rounded to the applicable scale interval and in mathematical agreement with L × W × H (the product's answer to R 129-1, 2.2.4/4.1.6)."
102
+ quantity_kind volume
103
+ unit "cm3"
104
+ value_type QuantityValue
105
+ origin measured
106
+ scope sample
107
+ category metrological
108
+ }
109
+
110
+ attribute_definition dim_weight {
111
+ symbol "DW"
112
+ name "Dimensional weight"
113
+ definition "The dimensional weight, DW = DV / F with the marked conversion factor F (the product's answer to R 129-1, 2.2.7/4.1.6)."
114
+ quantity_kind mass
115
+ unit kg
116
+ value_type QuantityValue
117
+ origin measured
118
+ scope sample
119
+ category metrological
120
+ }
121
+
122
+ state_machine md_operational {
123
+ kind operational
124
+ initial off
125
+ states { off warming ready measuring fault }
126
+ transition off -> warming action power_on
127
+ transition warming -> ready action warmed
128
+ transition ready -> measuring action start_measurement
129
+ transition measuring -> ready action stop_measurement
130
+ transition [off, warming, ready, measuring] -> fault action fault_detected
131
+ }
132
+
133
+ behavior optical_scanning {
134
+ kind static
135
+ stimulus object-dimensions
136
+ response "The light-section measurement: laser-line triangulation across the measuring frame plus the beam-cutting object detection along the conveyor produce the cross-section samples from which the length, width and height of the smallest enclosing rectangular box are computed (the product's answer to R 129-1, 2.1.1; optical principle, R 129-2, Annex A, Table A.1)."
137
+ }
138
+
139
+ behavior speed_response {
140
+ kind dynamic
141
+ stimulus object-speed
142
+ response "The indication stays within the maximum permissible errors over the declared measuring-speed range V_min to V_max (0.1–1.5 m/s) — the along-track sampling resolution scales with the conveyor speed (the product's answer to R 129-2, Annex A, the speed-of-movement test)."
143
+ }
144
+
145
+ behavior temperature_response {
146
+ kind influence-response
147
+ stimulus temperature
148
+ response "The indication stays within the maximum permissible errors over the rated temperature range −10…+40 °C — the measuring-frame geometry compensation holds (the product's answer to R 129-1, 4.2.1(b))."
149
+ }
150
+
151
+ behavior ambient_light_response {
152
+ kind influence-response
153
+ stimulus ambient-light
154
+ response "The optical measuring chain stays within the maximum permissible errors under ambient light from 100 lx to 1500 lx (the product's answer to R 129-1, 4.4 and the R 129-2, A.4.1 ambient-light test)."
155
+ }
156
+
157
+ behavior warm_up {
158
+ kind temporal
159
+ stimulus time
160
+ response "As soon as the instrument indicates, prints, stores or transmits results after switch-on, the indications are within the mpe — verified at 0, 5, 15 and 30 min (the product's answer to R 129-1, 5.1.7)."
161
+ }
162
+
163
+ behavior self_test {
164
+ kind procedural
165
+ stimulus invoke
166
+ response "The checking facilities run: a detected significant fault makes the instrument inoperative automatically (the automatic-instrument reaction of R 129-1, 5.6.1) — the operational state machine drives to fault and measurement is refused."
167
+ }
168
+
169
+ subject MD350 {
170
+ is {
171
+ metadata {
172
+ name "MD-350 multi-dimensional measuring instrument model"
173
+ designation "MD-350 optical automatic conveyor dimensioner (light-section, irregular-allowed, AC mains)"
174
+ }
175
+ provenance {
176
+ manufacturer "ACME Logistics Systems GmbH (FICTIONAL — demo manufacturer)"
177
+ certificate "R129/2026-DE-26-042 (FICTIONAL — demo value)"
178
+ type_evaluation_report "ACME-TE-2026-114 (FICTIONAL — demo value)"
179
+ promises_as_verified "±1 d per axis over 5–250 × 5–120 × 5–180 cm, 0.1–1.5 m/s and −10…+40 °C (the demo certificate's content — the claims as verified, distinct from the claims as declared, §15.2)"
180
+ }
181
+ design_parameters {
182
+ d : "0.5 cm"
183
+ min_dimension : "5 cm"
184
+ max_length : "250 cm"
185
+ max_width : "120 cm"
186
+ max_height : "180 cm"
187
+ v_min : "0.1 m/s"
188
+ v_max : "1.5 m/s"
189
+ t_min : "-10 degC"
190
+ t_max : "40 degC"
191
+ u_nom : "230 V"
192
+ conv_factor : "5000 cm3/kg"
193
+ }
194
+ promises {
195
+ mpe_within_length {
196
+ target error_hold_length
197
+ level { value 1 unit d }
198
+ conditions ocl{self.temperature >= rated.t_min and self.temperature <= rated.t_max}
199
+ statement "The length axis error of indication stays within ±1.0 d (d = 0.5 cm) across the 5–250 cm range, for initial and subsequent verification (R 129-1, 4.1.2)."
200
+ verified_by { oiml-r129#/req/metrological/mpe }
201
+ }
202
+ mpe_within_width {
203
+ target error_hold_width
204
+ level { value 1 unit d }
205
+ conditions ocl{self.temperature >= rated.t_min and self.temperature <= rated.t_max}
206
+ statement "The width axis error of indication stays within ±1.0 d across the 5–120 cm range, for initial and subsequent verification (R 129-1, 4.1.2)."
207
+ verified_by { oiml-r129#/req/metrological/mpe }
208
+ }
209
+ mpe_within_height {
210
+ target error_hold_height
211
+ level { value 1 unit d }
212
+ conditions ocl{self.temperature >= rated.t_min and self.temperature <= rated.t_max}
213
+ statement "The height axis error of indication stays within ±1.0 d across the 5–180 cm range, for initial and subsequent verification (R 129-1, 4.1.2)."
214
+ verified_by { oiml-r129#/req/metrological/mpe }
215
+ }
216
+ volume_agrees {
217
+ target volume_consistency
218
+ statement "The served dimensional volume is derived from the indicated dimensions rounded to the scale interval and is in mathematical agreement with L × W × H; the dimensional weight applies the marked conversion factor (R 129-1, 4.1.6)."
219
+ verified_by { oiml-r129#/req/metrological/calculated-quantities }
220
+ }
221
+ speed_envelope {
222
+ target speed_response
223
+ level range { min 0.1 max 1.5 unit m/s }
224
+ statement "Measurements at any relative speed in the V_min…V_max range 0.1–1.5 m/s stay within the mpe (R 129-2, Annex A, the speed-of-movement test at both bounds)."
225
+ verified_by { oiml-r129#/req/object-limitations/speed-movement }
226
+ }
227
+ temp_envelope {
228
+ target temperature_response
229
+ level range { min -10 max 40 unit degC }
230
+ conditions "over the rated operating conditions (mains 230 V −15 %/+10 %, 85 % RH at the upper temperature limit)"
231
+ statement "The rated temperature envelope spans −10…+40 °C — the R 129-1, 4.2.1(b) default envelope."
232
+ verified_by { oiml-r129#/req/electronic/rated-operating-conditions }
233
+ }
234
+ light_immunity {
235
+ target ambient_light_response
236
+ level range { min 100 max 1500 unit lx }
237
+ statement "The optical chain stays within the mpe under ambient light from 100 lx to 1500 lx (R 129-1, 4.4; the R 129-2, A.4.1 test range)."
238
+ verified_by { oiml-r129#/req/electronic/light-acoustic-effects }
239
+ }
240
+ warm_up_within {
241
+ target warm_up
242
+ statement "From the first indication after switch-on the instrument operates within the mpe — verified at 0, 5, 15 and 30 min (R 129-1, 5.1.7)."
243
+ verified_by { oiml-r129#/req/technical/warm-up }
244
+ }
245
+ self_check_reacts {
246
+ target self_test
247
+ statement "A detected significant fault makes the instrument inoperative automatically — the automatic-instrument reaction (R 129-1, 5.6.1)."
248
+ verified_by { oiml-r129#/req/technical/checking-significant-faults }
249
+ }
250
+ fault_annunciation {
251
+ target self_test
252
+ statement "Under disturbances either no significant fault occurs (a fault ≤ d is allowed) or the fault is detected and acted upon — the state machine drives to fault and measurement is refused (R 129-1, 4.3.1)."
253
+ verified_by { oiml-r129#/req/electronic/disturbance-resistance }
254
+ }
255
+ irregular_objects {
256
+ target optical_scanning
257
+ statement "Irregular-shaped objects are measured as the smallest enclosing rectangular box — the instrument is not restricted to rectangular boxes and carries no such marking (R 129-1, 5.3/A.2)."
258
+ verified_by { oiml-r129#/req/object-limitations/object-shape }
259
+ }
260
+ surface_robustness {
261
+ target optical_scanning
262
+ statement "Objects from shiny white to matt black and of varying surface finish are measured within the marked limitations (R 129-1, A.3)."
263
+ verified_by { oiml-r129#/req/object-limitations/surface-reflectivity }
264
+ }
265
+ orientation_robustness {
266
+ target optical_scanning
267
+ statement "The measurement does not depend on a particular orientation or position of the object on the conveyor — results stay within the mpe across orientations (R 129-1, A.4)."
268
+ verified_by { oiml-r129#/req/object-limitations/orientation-position }
269
+ }
270
+ }
271
+ endpoint md350_api {
272
+ operation get_dimensions { kind query serves { indication_length indication_width indication_height } payload { quantity_kind length unit cm timestamp true } }
273
+ operation get_volume { kind query serves { dim_volume } payload { quantity_kind volume unit cm3 timestamp true } }
274
+ operation get_dim_weight { kind query serves { dim_weight } payload { quantity_kind mass unit kg timestamp true } }
275
+ operation watch_state { kind subscribe serves { state environmental_context } payload { quantity_kind state unit dimensionless timestamp true } }
276
+ operation run_self_test { kind invoke does { self_test } payload { quantity_kind diagnostic_report unit dimensionless timestamp true } }
277
+ access { public { get_dimensions get_volume get_dim_weight } registered { watch_state } authority { run_self_test } }
278
+ profile rest_json
279
+ }
280
+ }
281
+ has {
282
+ attributes {
283
+ indication_length : length test_dependent
284
+ indication_width : length test_dependent
285
+ indication_height : length test_dependent
286
+ reference_length : length test_dependent
287
+ reference_width : length test_dependent
288
+ reference_height : length test_dependent
289
+ dim_volume : volume test_dependent
290
+ dim_weight : mass test_dependent
291
+ conveyor_speed : speed test_dependent
292
+ }
293
+ dimensions { measurement_principle : optical instrument_category : automatic power_supply : ac-mains object_capability : irregular-allowed }
294
+ characteristics {
295
+ error_hold_length e_l = ocl{self.indication_length - self.reference_length}
296
+ error_hold_width e_w = ocl{self.indication_width - self.reference_width}
297
+ error_hold_height e_h = ocl{self.indication_height - self.reference_height}
298
+ volume_consistency dv = ocl{self.dim_volume - self.indication_length * self.indication_width * self.indication_height}
299
+ }
300
+ state md_operational
301
+ serve sample.indication_length via get_dimensions { fresh_within 2s }
302
+ serve sample.indication_width via get_dimensions { fresh_within 2s }
303
+ serve sample.indication_height via get_dimensions { fresh_within 2s }
304
+ serve sample.dim_volume via get_volume { fresh_within 2s }
305
+ serve sample.dim_weight via get_dim_weight { fresh_within 2s }
306
+ serve sample.state via watch_state { fresh_within 1s }
307
+ serve sample.environmental_context via watch_state { fresh_within 1s }
308
+ }
309
+ does {
310
+ behavior optical_scanning
311
+ behavior speed_response
312
+ behavior temperature_response
313
+ behavior ambient_light_response
314
+ behavior warm_up
315
+ behavior self_test
316
+ }
317
+ }