@oimlsmart/primmel-packages 0.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (460) hide show
  1. package/AGENTS.md +60 -0
  2. package/LICENSE +21 -0
  3. package/README.md +68 -0
  4. package/acme-cgm-200/model/cgm200.prl +284 -0
  5. package/acme-cgm-200/model/r144-map.prl +337 -0
  6. package/acme-cgm-200/package.primmel +39 -0
  7. package/acme-cgm-system/model/cgm-system.prl +125 -0
  8. package/acme-cgm-system/model/r144-map.prl +75 -0
  9. package/acme-cgm-system/model/sample-line.prl +42 -0
  10. package/acme-cgm-system/package.primmel +23 -0
  11. package/acme-lc500/model/lc500.prl +218 -0
  12. package/acme-lc500/model/passport.prl +43 -0
  13. package/acme-lc500/model/r60-map.prl +161 -0
  14. package/acme-lc500/model/twin-cert-map.prl +114 -0
  15. package/acme-lc500/package.primmel +35 -0
  16. package/acme-md3xx/model/md350.prl +317 -0
  17. package/acme-md3xx/model/r129-map.prl +346 -0
  18. package/acme-md3xx/package.primmel +49 -0
  19. package/acme-rs180/model/r91-map.prl +234 -0
  20. package/acme-rs180/model/rs180.prl +236 -0
  21. package/acme-rs180/package.primmel +47 -0
  22. package/ims-demo/model/ims.prl +23 -0
  23. package/ims-demo/model/isms-map.prl +60 -0
  24. package/ims-demo/model/qms-map.prl +73 -0
  25. package/ims-demo/package.primmel +42 -0
  26. package/isms-ref/model/isms.prl +34 -0
  27. package/isms-ref/package.primmel +35 -0
  28. package/iso-iec-17000/package.primmel +8 -0
  29. package/iso-iec-17000/terminology.prl +268 -0
  30. package/iso-iec-17025/package.primmel +10 -0
  31. package/iso-iec-17025/specification/requirements/lab.prl +474 -0
  32. package/iso-iec-17025/terminology.prl +72 -0
  33. package/iso-iec-17065/package.primmel +10 -0
  34. package/iso-iec-17065/specification/requirements/body.prl +446 -0
  35. package/iso-iec-17065/terminology.prl +103 -0
  36. package/iso-iec-17067/package.primmel +10 -0
  37. package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
  38. package/iso-iec-17067/terminology.prl +24 -0
  39. package/oiml-cs/package.primmel +10 -0
  40. package/oiml-cs/specification/discrepancies.prl +26 -0
  41. package/oiml-cs/specification/requirements/cs.prl +515 -0
  42. package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
  43. package/oiml-cs-dataspace/package.primmel +9 -0
  44. package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
  45. package/oiml-cs-dataspace/specification/policies.prl +68 -0
  46. package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
  47. package/oiml-integrated-ref/package.primmel +10 -0
  48. package/oiml-r129/.primmel-allowlist.prl +2 -0
  49. package/oiml-r129/evaluation/processes.prl +152 -0
  50. package/oiml-r129/evaluation/workflow.prl +48 -0
  51. package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
  52. package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
  53. package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
  54. package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
  55. package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
  56. package/oiml-r129/execution/forms/admin/identification.prl +49 -0
  57. package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
  58. package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
  59. package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
  60. package/oiml-r129/execution/forms/emc/esd.prl +66 -0
  61. package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
  62. package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
  63. package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
  64. package/oiml-r129/execution/forms/emc/surge.prl +61 -0
  65. package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
  66. package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
  67. package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
  68. package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
  69. package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
  70. package/oiml-r129/execution/forms/shared/headers.prl +86 -0
  71. package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
  72. package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
  73. package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
  74. package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
  75. package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
  76. package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
  77. package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
  78. package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
  79. package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
  80. package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
  81. package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
  82. package/oiml-r129/layers.prl +50 -0
  83. package/oiml-r129/model/attributes.prl +243 -0
  84. package/oiml-r129/model/behaviors.prl +79 -0
  85. package/oiml-r129/model/capabilities.prl +29 -0
  86. package/oiml-r129/model/characteristics.prl +8 -0
  87. package/oiml-r129/model/conditions.prl +23 -0
  88. package/oiml-r129/model/instrument.prl +67 -0
  89. package/oiml-r129/model/state.prl +22 -0
  90. package/oiml-r129/model/twin.prl +23 -0
  91. package/oiml-r129/package.primmel +15 -0
  92. package/oiml-r129/payload/application.yaml +40 -0
  93. package/oiml-r129/payload/conditions-common-test.yaml +8 -0
  94. package/oiml-r129/payload/formulas-variants.yaml +33 -0
  95. package/oiml-r129/payload/promises.yaml +102 -0
  96. package/oiml-r129/payload/sample-data.yaml +300 -0
  97. package/oiml-r129/references.prl +306 -0
  98. package/oiml-r129/sources-prd/coverage.json +59 -0
  99. package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
  100. package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
  101. package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
  102. package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
  103. package/oiml-r129/specification/calculations.prl +83 -0
  104. package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
  105. package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
  106. package/oiml-r129/specification/conformance/examinations.prl +83 -0
  107. package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
  108. package/oiml-r129/specification/formulas.prl +9 -0
  109. package/oiml-r129/specification/requirements/electronic.prl +46 -0
  110. package/oiml-r129/specification/requirements/metrological.prl +83 -0
  111. package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
  112. package/oiml-r129/specification/requirements/software.prl +57 -0
  113. package/oiml-r129/specification/requirements/technical.prl +134 -0
  114. package/oiml-r129/specification/symbols.prl +187 -0
  115. package/oiml-r129/specification/tables.prl +74 -0
  116. package/oiml-r129/terminology.prl +415 -0
  117. package/oiml-r129/value-types.prl +40 -0
  118. package/oiml-r144/.primmel-allowlist.prl +2 -0
  119. package/oiml-r144/entities/instrument.prl +360 -0
  120. package/oiml-r144/entities/test-execution.prl +228 -0
  121. package/oiml-r144/entities/workflow.prl +2075 -0
  122. package/oiml-r144/evaluation/processes.prl +152 -0
  123. package/oiml-r144/evaluation/workflow.prl +48 -0
  124. package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
  125. package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
  126. package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
  127. package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
  128. package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
  129. package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
  130. package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
  131. package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
  132. package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
  133. package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
  134. package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
  135. package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
  136. package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
  137. package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
  138. package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
  139. package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
  140. package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
  141. package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
  142. package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
  143. package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
  144. package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
  145. package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
  146. package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
  147. package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
  148. package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
  149. package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
  150. package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
  151. package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
  152. package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
  153. package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
  154. package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
  155. package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
  156. package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
  157. package/oiml-r144/execution/forms/shared/headers.prl +132 -0
  158. package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
  159. package/oiml-r144/layers.prl +44 -0
  160. package/oiml-r144/model/attributes.prl +679 -0
  161. package/oiml-r144/model/behaviors.prl +117 -0
  162. package/oiml-r144/model/capabilities.prl +99 -0
  163. package/oiml-r144/model/characteristics.prl +27 -0
  164. package/oiml-r144/model/conditions.prl +46 -0
  165. package/oiml-r144/model/instrument.prl +85 -0
  166. package/oiml-r144/model/state.prl +18 -0
  167. package/oiml-r144/model/twin.prl +25 -0
  168. package/oiml-r144/package.primmel +15 -0
  169. package/oiml-r144/payload/application.yaml +80 -0
  170. package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
  171. package/oiml-r144/payload/conditions-common-test.yaml +74 -0
  172. package/oiml-r144/payload/formulas-variants.yaml +32 -0
  173. package/oiml-r144/payload/promises.yaml +118 -0
  174. package/oiml-r144/payload/sample-data.yaml +643 -0
  175. package/oiml-r144/references.prl +594 -0
  176. package/oiml-r144/sources-prd/coverage.json +114 -0
  177. package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
  178. package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
  179. package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
  180. package/oiml-r144/specification/calculations.prl +123 -0
  181. package/oiml-r144/specification/conformance/examination.prl +87 -0
  182. package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
  183. package/oiml-r144/specification/formulas.prl +37 -0
  184. package/oiml-r144/specification/reference-materials.prl +87 -0
  185. package/oiml-r144/specification/requirements/controls.prl +51 -0
  186. package/oiml-r144/specification/requirements/metrological.prl +299 -0
  187. package/oiml-r144/specification/requirements/report.prl +35 -0
  188. package/oiml-r144/specification/requirements/technical.prl +455 -0
  189. package/oiml-r144/specification/symbols.prl +357 -0
  190. package/oiml-r144/specification/tables.prl +95 -0
  191. package/oiml-r144/specification/test-point-sets.prl +15 -0
  192. package/oiml-r144/terminology.prl +308 -0
  193. package/oiml-r144/value-types.prl +49 -0
  194. package/oiml-r60/.primmel-allowlist.prl +2 -0
  195. package/oiml-r60/entities/workflow.prl +2079 -0
  196. package/oiml-r60/evaluation/processes.prl +152 -0
  197. package/oiml-r60/evaluation/workflow.prl +48 -0
  198. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
  199. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
  200. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
  201. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
  202. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
  203. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
  204. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
  205. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
  206. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
  207. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
  208. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
  209. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
  210. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
  211. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
  212. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
  213. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
  214. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
  215. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
  216. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
  217. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
  218. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
  219. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
  220. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
  221. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
  222. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
  223. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
  224. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
  225. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
  226. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
  227. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
  228. package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
  229. package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
  230. package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
  231. package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
  232. package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
  233. package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
  234. package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
  235. package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
  236. package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
  237. package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
  238. package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
  239. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
  240. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
  241. package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
  242. package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
  243. package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
  244. package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
  245. package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
  246. package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
  247. package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
  248. package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
  249. package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
  250. package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
  251. package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
  252. package/oiml-r60/execution/forms/shared/headers.prl +255 -0
  253. package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
  254. package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
  255. package/oiml-r60/layers.prl +46 -0
  256. package/oiml-r60/model/attributes.prl +642 -0
  257. package/oiml-r60/model/behaviors.prl +165 -0
  258. package/oiml-r60/model/capabilities.prl +57 -0
  259. package/oiml-r60/model/characteristics.prl +27 -0
  260. package/oiml-r60/model/conditions.prl +50 -0
  261. package/oiml-r60/model/instrument.prl +96 -0
  262. package/oiml-r60/model/processes.prl +54 -0
  263. package/oiml-r60/model/state.prl +22 -0
  264. package/oiml-r60/model/twin.prl +16 -0
  265. package/oiml-r60/package.primmel +16 -0
  266. package/oiml-r60/payload/annexes-part4.yaml +122 -0
  267. package/oiml-r60/payload/application.yaml +83 -0
  268. package/oiml-r60/payload/conditions-common-test.yaml +121 -0
  269. package/oiml-r60/payload/formulas-variants.yaml +55 -0
  270. package/oiml-r60/payload/promises.yaml +224 -0
  271. package/oiml-r60/payload/sample-data.yaml +5025 -0
  272. package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
  273. package/oiml-r60/references.prl +549 -0
  274. package/oiml-r60/sources-prd/coverage.json +740 -0
  275. package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
  276. package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
  277. package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
  278. package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
  279. package/oiml-r60/specification/calculations.prl +318 -0
  280. package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
  281. package/oiml-r60/specification/conformance/electronic.prl +483 -0
  282. package/oiml-r60/specification/conformance/examination.prl +183 -0
  283. package/oiml-r60/specification/conformance/metrological.prl +478 -0
  284. package/oiml-r60/specification/constraints.prl +58 -0
  285. package/oiml-r60/specification/formulas-used.prl +43 -0
  286. package/oiml-r60/specification/formulas.prl +20 -0
  287. package/oiml-r60/specification/requirements/class-specific.prl +655 -0
  288. package/oiml-r60/specification/requirements/classification.prl +114 -0
  289. package/oiml-r60/specification/requirements/electronic.prl +222 -0
  290. package/oiml-r60/specification/requirements/metrological.prl +381 -0
  291. package/oiml-r60/specification/requirements/technical.prl +146 -0
  292. package/oiml-r60/specification/symbols.prl +599 -0
  293. package/oiml-r60/specification/tables.prl +182 -0
  294. package/oiml-r60/specification/test-sequences.prl +72 -0
  295. package/oiml-r60/terminology.prl +920 -0
  296. package/oiml-r60/value-types.prl +46 -0
  297. package/oiml-r91/.primmel-allowlist.prl +3 -0
  298. package/oiml-r91/entities/instrument.prl +359 -0
  299. package/oiml-r91/entities/workflow.prl +2075 -0
  300. package/oiml-r91/evaluation/processes.prl +152 -0
  301. package/oiml-r91/evaluation/workflow.prl +48 -0
  302. package/oiml-r91/execution/forms/evidence-file.prl +41 -0
  303. package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
  304. package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
  305. package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
  306. package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
  307. package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
  308. package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
  309. package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
  310. package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
  311. package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
  312. package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
  313. package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
  314. package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
  315. package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
  316. package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
  317. package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
  318. package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
  319. package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
  320. package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
  321. package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
  322. package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
  323. package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
  324. package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
  325. package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
  326. package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
  327. package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
  328. package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
  329. package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
  330. package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
  331. package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
  332. package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
  333. package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
  334. package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
  335. package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
  336. package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
  337. package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
  338. package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
  339. package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
  340. package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
  341. package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
  342. package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
  343. package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
  344. package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
  345. package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
  346. package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
  347. package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
  348. package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
  349. package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
  350. package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
  351. package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
  352. package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
  353. package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
  354. package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
  355. package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
  356. package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
  357. package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
  358. package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
  359. package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
  360. package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
  361. package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
  362. package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
  363. package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
  364. package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
  365. package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
  366. package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
  367. package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
  368. package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
  369. package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
  370. package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
  371. package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
  372. package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
  373. package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
  374. package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
  375. package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
  376. package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
  377. package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
  378. package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
  379. package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
  380. package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
  381. package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
  382. package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
  383. package/oiml-r91/layers.prl +46 -0
  384. package/oiml-r91/model/artifacts.prl +29 -0
  385. package/oiml-r91/model/attributes.prl +698 -0
  386. package/oiml-r91/model/behaviors.prl +142 -0
  387. package/oiml-r91/model/capabilities.prl +88 -0
  388. package/oiml-r91/model/characteristics.prl +27 -0
  389. package/oiml-r91/model/conditions.prl +37 -0
  390. package/oiml-r91/model/instrument.prl +147 -0
  391. package/oiml-r91/model/state.prl +22 -0
  392. package/oiml-r91/model/twin.prl +17 -0
  393. package/oiml-r91/package.primmel +14 -0
  394. package/oiml-r91/payload/application.yaml +201 -0
  395. package/oiml-r91/payload/conditions-common-test.yaml +19 -0
  396. package/oiml-r91/payload/promises.yaml +142 -0
  397. package/oiml-r91/payload/sample-data.yaml +464 -0
  398. package/oiml-r91/references.prl +72 -0
  399. package/oiml-r91/sources-prd/coverage.json +106 -0
  400. package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
  401. package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
  402. package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
  403. package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
  404. package/oiml-r91/specification/calculations.prl +26 -0
  405. package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
  406. package/oiml-r91/specification/conformance/metrological.prl +906 -0
  407. package/oiml-r91/specification/formulas.prl +10 -0
  408. package/oiml-r91/specification/requirements/class-specific.prl +308 -0
  409. package/oiml-r91/specification/requirements/metrological.prl +176 -0
  410. package/oiml-r91/specification/requirements/technical.prl +173 -0
  411. package/oiml-r91/specification/symbols.prl +323 -0
  412. package/oiml-r91/specification/tables.prl +136 -0
  413. package/oiml-r91/terminology.prl +535 -0
  414. package/oiml-r91/value-types.prl +26 -0
  415. package/oiml-smart-core/entities/comments.prl +101 -0
  416. package/oiml-smart-core/entities/cs-operations.prl +492 -0
  417. package/oiml-smart-core/entities/cs-participants.prl +470 -0
  418. package/oiml-smart-core/entities/engagement.prl +323 -0
  419. package/oiml-smart-core/entities/instrument.prl +359 -0
  420. package/oiml-smart-core/entities/module-b.prl +214 -0
  421. package/oiml-smart-core/entities/operated-schemes.prl +141 -0
  422. package/oiml-smart-core/entities/parties.prl +429 -0
  423. package/oiml-smart-core/entities/payment-records.prl +92 -0
  424. package/oiml-smart-core/entities/verification.prl +187 -0
  425. package/oiml-smart-core/entities/workflow.prl +2075 -0
  426. package/oiml-smart-core/evaluation/roles.prl +65 -0
  427. package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
  428. package/oiml-smart-core/package.primmel +10 -0
  429. package/oiml-smart-core/specification/competence-kinds.prl +64 -0
  430. package/oiml-smart-core/specification/constraints.prl +40 -0
  431. package/oiml-smart-core/specification/invariants.prl +90 -0
  432. package/oiml-smart-core/specification/predicates.prl +116 -0
  433. package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
  434. package/oiml-smart-module-env-iec60068/package.primmel +10 -0
  435. package/oiml-smart-module-examination-docs/package.primmel +10 -0
  436. package/oiml-smart-module-reference-materials/package.primmel +10 -0
  437. package/oiml-smart-module-report-headers/package.primmel +10 -0
  438. package/oiml-smart-module-software-d31/package.primmel +10 -0
  439. package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
  440. package/oiml-smart-module-specimen-governance/package.primmel +10 -0
  441. package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
  442. package/oiml-twin-cert/evaluation/roles.prl +15 -0
  443. package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
  444. package/oiml-twin-cert/execution/forms/probe.prl +99 -0
  445. package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
  446. package/oiml-twin-cert/model/attributes.prl +243 -0
  447. package/oiml-twin-cert/model/behaviors.prl +8 -0
  448. package/oiml-twin-cert/model/characteristics.prl +18 -0
  449. package/oiml-twin-cert/model/monitors.prl +16 -0
  450. package/oiml-twin-cert/package.primmel +16 -0
  451. package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
  452. package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
  453. package/oiml-twin-cert/specification/symbols.prl +36 -0
  454. package/oiml-twin-cert/terminology.prl +8 -0
  455. package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
  456. package/package.json +17 -0
  457. package/qms-ref/model/qms.prl +31 -0
  458. package/qms-ref/package.primmel +38 -0
  459. package/quarry-belt-scale/model/ops.prl +115 -0
  460. package/quarry-belt-scale/package.primmel +36 -0
@@ -0,0 +1,327 @@
1
+ form r60-3/table-6.8 {
2
+ name "Creep DR"
3
+ description "Creep (C_C) and minimum dead load output return (C_DR)"
4
+ data_class FormInstance#data
5
+ header r60-3/header-a
6
+ conformance_process { /conf/metrological-tests/creep /conf/metrological-tests/dr }
7
+ section "R 60-3, 6.8"
8
+ requirements { /req/metrological/creep /req/metrological/creep-20-30 /req/metrological/dr }
9
+ ref requirement "urn:oiml:pub:r:60-1:2021#clause-5.5.1"
10
+ ref requirement "urn:oiml:pub:r:60-1:2021#clause-5.5.2"
11
+ ref test-procedure "urn:oiml:pub:r:60-2:2021#clause-2.10.2"
12
+ ref test-procedure "urn:oiml:pub:r:60-2:2021#clause-2.10.3"
13
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.1.5"
14
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.1.5.2"
15
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.1.5.4"
16
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.8"
17
+ ref report-format "urn:oiml:pub:r:60-3:2021#table-6"
18
+ calculation_context { dimensions true tables { mpe_tiers } }
19
+ field conversion_factor_f : number {
20
+ label "Conversion factor (f)"
21
+ definition "Ratio of indication change to load change at 75% of Max. Converts counts to verification units (v)."
22
+ unit "counts/v"
23
+ required true
24
+ measurement_method computed
25
+ bind sample.test_context.conversion_factor_f
26
+ symbol f
27
+ specification_reference "R 60-3, 2.1.2.4"
28
+ calculation conversionFactor
29
+ calculation_bindings { avgIndicationAt75pct: reference_indication_75pct indicationAtDmin: indication_at_dmin n: n_test_intervals }
30
+ }
31
+ field reference_indication_75pct : number {
32
+ label "Reference indication at 75%"
33
+ definition "Average indication at the 75% load point, used to compute f."
34
+ unit "counts"
35
+ required true
36
+ measurement_method direct
37
+ }
38
+ field indication_at_dmin : number {
39
+ label "Indication at D_min"
40
+ definition "Load cell indication at minimum test load (D_min) used to compute f."
41
+ unit "counts"
42
+ required true
43
+ measurement_method direct
44
+ }
45
+ field n_lc : integer {
46
+ label "Number of verification intervals (n_LC)"
47
+ definition "Maximum number of load cell verification intervals n_LC, declared by the manufacturer."
48
+ required true
49
+ measurement_method declared
50
+ bind group.parameters.n_lc
51
+ symbol nLC
52
+ specification_reference "R 60-1, 3.5.8"
53
+ }
54
+ field y : integer {
55
+ label "Relative v_min (Y)"
56
+ definition "Ratio of the maximum measuring range to v_min (Y = (E_max - E_min)/v_min)."
57
+ measurement_method declared
58
+ bind group.parameters.y
59
+ symbol Y
60
+ specification_reference "R 60-1, 3.5.15"
61
+ }
62
+ field emax : number {
63
+ label "Maximum capacity (E_max)"
64
+ definition "Maximum capacity of the load cell."
65
+ unit "g, kg, or t"
66
+ required true
67
+ measurement_method declared
68
+ bind model.parameters.e_max
69
+ symbol Emax
70
+ specification_reference "R 60-1, 3.5.5"
71
+ }
72
+ field emin : number {
73
+ label "Minimum dead load (E_min)"
74
+ definition "Minimum dead load of the load cell."
75
+ unit "g, kg, or t"
76
+ measurement_method declared
77
+ bind family.parameters.e_min
78
+ symbol Emin
79
+ specification_reference "R 60-1, 3.5.9"
80
+ }
81
+ field vmin : number {
82
+ label "Minimum verification interval (v_min)"
83
+ definition "Minimum load cell verification interval."
84
+ unit "g, kg, or t"
85
+ required true
86
+ measurement_method declared
87
+ bind group.parameters.v_min
88
+ symbol vmin
89
+ specification_reference "R 60-1, 3.5.11"
90
+ }
91
+ field n_test_intervals : number {
92
+ label "Verification intervals of the tested range (n)"
93
+ definition "Number of verification intervals of the measuring range under test — (E_max − E_min)/v_min when the test spans the classified range (R 60-3, 2.1.2.4). Input n of the conversion-factor calculation."
94
+ measurement_method derived
95
+ symbol n
96
+ specification_reference "R 60-3, 2.1.2.4"
97
+ derivation "ocl{(emax - emin) / vmin}"
98
+ }
99
+ field dmin : number {
100
+ label "Minimum test load (D_min)"
101
+ definition "The minimum test load (dead load) applied during the creep test."
102
+ unit "g, kg, or t"
103
+ required true
104
+ measurement_method declared
105
+ bind sample.test_context.d_min
106
+ symbol Dmin
107
+ }
108
+ field dmax : number {
109
+ label "Maximum test load (D_max)"
110
+ definition "The maximum test load applied during the creep test."
111
+ unit "g, kg, or t"
112
+ required true
113
+ measurement_method declared
114
+ bind sample.test_context.d_max
115
+ symbol Dmax
116
+ }
117
+ field initial_dmin_indication : number {
118
+ label "Initial D_min indication"
119
+ definition "The load cell indication (counts) at D_min before the creep load is applied. Reference point for DR calculation."
120
+ unit "counts"
121
+ measurement_method direct
122
+ }
123
+ field initial_dmax_indication : number {
124
+ label "Initial D_max indication"
125
+ definition "The load cell indication (counts) at D_max immediately after loading. Reference point for creep calculation."
126
+ unit "counts"
127
+ measurement_method direct
128
+ }
129
+ field creep_readings : array {
130
+ label "Creep readings"
131
+ definition "Time-series indication readings during the creep test at D_max (and D_min). Creep is the change in indication over time under constant load."
132
+ items { object fields {
133
+ field test_load : string {
134
+ label "Test load"
135
+ definition "The load applied at this reading point: D_min or D_max."
136
+ measurement_method declared
137
+ }
138
+ field indication_counts : number {
139
+ label "Indication (counts)"
140
+ definition "Load cell indication reading at this time point."
141
+ unit "counts"
142
+ measurement_method direct
143
+ }
144
+ field elapsed_min : number {
145
+ label "Elapsed time (min)"
146
+ definition "Time elapsed since the initial D_max loading, in minutes. The numeric time axis of the series — verdicts address readings by it (t = 20, t = 30 per R 60-3, 2.1.5.2), never by string matching or by extreme value."
147
+ unit "min"
148
+ measurement_method direct
149
+ specification_reference "R 60-3, 2.1.5.2"
150
+ }
151
+ field indication_time : string {
152
+ label "Indication time"
153
+ definition "Absolute time of the reading (HH:MM:SS)."
154
+ measurement_method direct
155
+ pattern "\\d{2}:\\d{2}:\\d{2}"
156
+ }
157
+ field barometric_pressure : number {
158
+ label "Barometric pressure"
159
+ definition "Atmospheric pressure at time of reading, for correction if needed."
160
+ unit "kPa"
161
+ measurement_method direct
162
+ }
163
+ field change_v : number {
164
+ label "Creep change (v)"
165
+ definition "Change in indication from the initial D_max loading, divided by f, in verification units."
166
+ unit "v"
167
+ measurement_method derived
168
+ symbol CC
169
+ specification_reference "R 60-3, 2.1.5"
170
+ calculation creep
171
+ calculation_bindings { indicationAtTime: indication_counts initialIndication: initial_dmax_indication conversion_factor_f: conversion_factor_f }
172
+ }
173
+ field elapsed_time : string {
174
+ label "Elapsed time"
175
+ definition "Time elapsed since the initial D_max loading (mm:ss) — recorded display companion of the numeric elapsed_min axis (verdicts address readings by elapsed_min, never by this string)."
176
+ measurement_method direct
177
+ }
178
+ } }
179
+ series { axis elapsed_min { unit "min" role time } cell { symbol change_v unit "v" } }
180
+ }
181
+ field dr_readings : array {
182
+ label "DR readings"
183
+ definition "Minimum dead load output return measurements after the creep test. DR is the difference between the final and initial D_min indications."
184
+ items { object fields {
185
+ field indication_counts : number {
186
+ label "Indication (counts)"
187
+ definition "Load cell indication after returning to D_min."
188
+ unit "counts"
189
+ measurement_method direct
190
+ }
191
+ field indication_time : string {
192
+ label "Time"
193
+ definition "Absolute time of DR reading (HH:MM:SS)."
194
+ measurement_method direct
195
+ pattern "\\d{2}:\\d{2}:\\d{2}"
196
+ }
197
+ field barometric_pressure : number {
198
+ label "Barometric pressure"
199
+ definition "Atmospheric pressure at time of DR reading."
200
+ unit "kPa"
201
+ measurement_method direct
202
+ }
203
+ field change_v : number {
204
+ label "DR change (v)"
205
+ definition "Change from initial D_min indication, divided by f. This is the dead load output return C_DR."
206
+ unit "v"
207
+ measurement_method derived
208
+ symbol CDR
209
+ specification_reference "R 60-3, 2.1.5.4"
210
+ calculation deadLoadOutputReturn
211
+ calculation_bindings { minLoadIndication2: indication_counts minLoadIndication1: initial_dmin_indication conversion_factor_f: conversion_factor_f }
212
+ }
213
+ } }
214
+ }
215
+ field max_creep_change_v : number {
216
+ label "Maximum creep change (v)"
217
+ definition "Maximum creep change across all D_max readings in verification units."
218
+ unit "v"
219
+ measurement_method derived
220
+ symbol CC
221
+ derivation "ocl{creep_readings->collect(r | r.change_v)->max()}"
222
+ }
223
+ field creep_30min : number {
224
+ label "Creep at 30 min (v)"
225
+ definition "Creep change at exactly the 30-minute reading, in verification units."
226
+ unit "v"
227
+ measurement_method derived
228
+ symbol CC
229
+ specification_reference "R 60-3, 2.1.5.2"
230
+ derivation "ocl{reading_at(window(creep_readings->select(r | r.test_load = 'D_max'), 'elapsed_min', 20, 30), 'elapsed_min', 30, 'change_v')}"
231
+ }
232
+ field creep_20min : number {
233
+ label "Creep at 20 min (v)"
234
+ definition "Creep change at the 20-minute reading, in verification units."
235
+ unit "v"
236
+ measurement_method derived
237
+ symbol CC
238
+ specification_reference "R 60-3, 2.1.5.2"
239
+ derivation "ocl{reading_at(window(creep_readings->select(r | r.test_load = 'D_max'), 'elapsed_min', 20, 30), 'elapsed_min', 20, 'change_v')}"
240
+ }
241
+ field creep_30_20_diff : number {
242
+ label "Creep 30-20 difference (v)"
243
+ definition "Difference between creep at 30 min and 20 min per R 60-3, 2.1.5.2."
244
+ unit "v"
245
+ measurement_method derived
246
+ symbol CC-30-20
247
+ specification_reference "R 60-3, 2.1.5.2"
248
+ derivation "ocl{creep_30min - creep_20min}"
249
+ }
250
+ field mpe_at_dmax : number {
251
+ label "MPE at D_max (v), p_LC = 0.7"
252
+ definition "Maximum permissible error at D_max with p_LC forced to 0.7 for creep evaluation per R 60-1, 5.5.1."
253
+ unit "v"
254
+ measurement_method lookup
255
+ symbol MPE
256
+ specification_reference "R 60-1, 5.5.1"
257
+ calculation mpe
258
+ calculation_bindings { load: dmax accuracy_class: accuracy_class p_lc: plc_for_creep }
259
+ }
260
+ field plc_for_creep : number {
261
+ label "Apportionment factor for creep"
262
+ definition "Apportionment factor fixed at 0.7 for creep MPE evaluation per R 60-1, 5.5.1."
263
+ measurement_method declared
264
+ default 0.7
265
+ }
266
+ field dr_value : number {
267
+ label "DR value (v)"
268
+ definition "Final dead load output return value in verification units."
269
+ unit "v"
270
+ measurement_method derived
271
+ symbol CDR
272
+ derivation "ocl{dr_readings->collect(r | r.change_v)->last()}"
273
+ }
274
+ field actual_time_s : number {
275
+ label "Actual test duration"
276
+ definition "Duration of the creep test in seconds."
277
+ unit "s"
278
+ measurement_method direct
279
+ }
280
+ field specified_time_s : number {
281
+ label "Specified test duration"
282
+ definition "Required test duration per R 60-2 in seconds."
283
+ unit "s"
284
+ measurement_method declared
285
+ specification_reference "R 60-2, 2.10.2"
286
+ }
287
+ field mpe_for_dr : number {
288
+ label "MPE for DR"
289
+ definition "Maximum permissible error for DR evaluation = 0.5 v."
290
+ unit "v"
291
+ measurement_method declared
292
+ specification_reference "R 60-1, 5.5.2"
293
+ }
294
+ field creep_30min_result : boolean {
295
+ label "30-min creep result"
296
+ definition "Whether the total creep over 30 minutes is within 0.7 x |MPE| at D_max."
297
+ measurement_method evaluated
298
+ true_label "Pass"
299
+ false_label "Fail"
300
+ evaluation { rule "ocl{abs(max_creep_change_v) <= 0.7 * abs(mpe_at_dmax)}" condition "|C_C(30 min)| <= 0.7 x |MPE|" specification_reference "R 60-1, 5.5.1" }
301
+ }
302
+ field creep_20_30_result : boolean {
303
+ label "20-30 min creep result"
304
+ definition "Whether the creep change between 20 and 30 minutes is within 0.15 x |MPE|."
305
+ measurement_method evaluated
306
+ true_label "Pass"
307
+ false_label "Fail"
308
+ evaluation { rule "ocl{abs(creep_30min - creep_20min) <= 0.15 * abs(mpe_at_dmax)}" condition "|C_C(30-20)| <= 0.15 x |MPE|" specification_reference "R 60-1, 5.5.1" }
309
+ }
310
+ field dr_half_v_result : boolean {
311
+ label "DR <= 0.5 v result"
312
+ definition "Whether the dead load output return does not exceed 0.5 v."
313
+ measurement_method evaluated
314
+ true_label "Pass"
315
+ false_label "Fail"
316
+ evaluation { rule "ocl{if actual_time_s / specified_time_s <= 1 then abs(dr_value) <= 0.5 else abs(dr_value) <= 0.5 * (1 - (actual_time_s / specified_time_s - 1)) endif}" condition "|C_DR| <= 0.5(1 - (x-1)) v with x = actual time/specified time (relaxed rule for 100-150 % loading times, R 60-3, 2.1.5.6)" specification_reference "R 60-3, 2.1.5.6" }
317
+ }
318
+ field dr_within_manuf_spec_result : boolean {
319
+ label "DR within manufacturer spec"
320
+ definition "Whether DR is within the manufacturer's specified DR value (if different from 0.5 v) — assessed by the evaluator against the declared group DR; no machine-computable rule (the declared DR is a group-level characteristic outside this form's sample scope)."
321
+ measurement_method declared
322
+ true_label "Pass"
323
+ false_label "Fail"
324
+ }
325
+ pass_fail { criteria "30-min creep C_C(t) <= 0.7 * |MPE|; 20-30 min difference C_C(30-20) <= 0.15 * |MPE|; C_DR <= 0.5 v (if time intervals met)" pass_if "ocl{creep_30min_result and creep_20_30_result and dr_half_v_result}" }
326
+ }
327
+
@@ -0,0 +1,115 @@
1
+ form r60-3/form-6.17 {
2
+ name "EMC Susceptibility"
3
+ description "Electromagnetic susceptibility test"
4
+ data_class FormInstance#data
5
+ header r60-3/header-a
6
+ conformance_process /conf/electronic-tests/emc-susceptibility
7
+ section "R 60-3, 6.17"
8
+ requirements { /req/electronic/disturbances }
9
+ ref requirement "urn:oiml:pub:r:60-1:2021#clause-5.7.2.5"
10
+ ref test-procedure "urn:oiml:pub:r:60-2:2021#clause-2.10.7.9"
11
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.7"
12
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.7.1"
13
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.7.2"
14
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.7.3"
15
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.7.4"
16
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.17"
17
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.17.1"
18
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.17.2"
19
+ ref report-format "urn:oiml:pub:r:60-3:2021#table-23"
20
+ field conversion_factor_f : number {
21
+ label "Conversion Factor F"
22
+ unit "counts/v"
23
+ required true
24
+ bind sample.test_context.conversion_factor_f
25
+ targets { /req/electronic/disturbances }
26
+ }
27
+ field dmin_value : number {
28
+ label "Dmin Value"
29
+ unit "g, kg, or t"
30
+ bind sample.test_context.d_min
31
+ targets { /req/electronic/disturbances }
32
+ }
33
+ field rate_of_sweep : string {
34
+ label "Rate Of Sweep"
35
+ targets { /req/electronic/disturbances }
36
+ }
37
+ field test_load : number {
38
+ label "Test Load"
39
+ unit "g, kg, or t"
40
+ targets { /req/electronic/disturbances }
41
+ }
42
+ field test_load_material : string {
43
+ label "Test Load Material"
44
+ targets { /req/electronic/disturbances }
45
+ }
46
+ field without_disturbance : object {
47
+ label "Without Disturbance"
48
+ targets { /req/electronic/disturbances }
49
+ fields {
50
+ field indication : number {
51
+ label "Indication"
52
+ unit "counts"
53
+ }
54
+ field difference : number {
55
+ label "Difference"
56
+ unit "v"
57
+ }
58
+ }
59
+ }
60
+ field disturbance_results : array {
61
+ label "Disturbance Results"
62
+ targets { /req/electronic/disturbances /req/electronic/no-significant-faults }
63
+ items { object fields {
64
+ field antenna : string {
65
+ label "Antenna"
66
+ }
67
+ field frequency_range_mhz : string {
68
+ label "Frequency Range Mhz"
69
+ description "e.g. 80-3000 MHz"
70
+ }
71
+ field polarisation : enum {
72
+ label "Polarisation"
73
+ values { vertical { label "Vertical" } horizontal { label "Horizontal" } }
74
+ }
75
+ field facing : enum {
76
+ label "Facing"
77
+ values { front { label "Front" } right { label "Right" } left { label "Left" } rear { label "Rear" } }
78
+ }
79
+ field indication : number {
80
+ label "Indication"
81
+ unit "counts"
82
+ }
83
+ field difference : number {
84
+ label "Difference"
85
+ unit "v"
86
+ calculation "ocl{(indication - without_disturbance.indication) / conversion_factor_f}"
87
+ }
88
+ field significant_fault : boolean {
89
+ label "Significant Fault"
90
+ true_label "Yes"
91
+ false_label "No"
92
+ calculation "ocl{abs(difference) > 1}"
93
+ }
94
+ field remarks : string {
95
+ label "Remarks"
96
+ }
97
+ } }
98
+ }
99
+ field test_setup_description : text {
100
+ label "Test Setup Description"
101
+ description "Form 6.17.2 - description of test setup"
102
+ targets { /req/electronic/disturbances }
103
+ }
104
+ field remarks : text {
105
+ label "Remarks"
106
+ }
107
+ field overall_result : boolean {
108
+ label "Overall Result"
109
+ required true
110
+ true_label "Pass"
111
+ false_label "Fail"
112
+ }
113
+ pass_fail { criteria "No significant fault (> v_min)" pass_if "ocl{disturbance_results->forAll(r | not r.significant_fault)}" }
114
+ }
115
+
@@ -0,0 +1,224 @@
1
+ form r60-3/form-6.16 {
2
+ name "ESD"
3
+ description "Electrostatic discharge test - direct and indirect application"
4
+ data_class FormInstance#data
5
+ header r60-3/header-a
6
+ conformance_process /conf/electronic-tests/esd
7
+ section "R 60-3, 6.16"
8
+ requirements { /req/electronic/disturbances }
9
+ ref requirement "urn:oiml:pub:r:60-1:2021#clause-5.7.2.5"
10
+ ref test-procedure "urn:oiml:pub:r:60-2:2021#clause-2.10.7.8"
11
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.6"
12
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.6.1"
13
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.6.2"
14
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.6.3"
15
+ ref calculation "urn:oiml:pub:r:60-3:2021#clause-2.2.6.4"
16
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.16"
17
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.16.1"
18
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.16.2"
19
+ ref report-format "urn:oiml:pub:r:60-3:2021#clause-6.16.3"
20
+ ref report-format "urn:oiml:pub:r:60-3:2021#table-20"
21
+ ref report-format "urn:oiml:pub:r:60-3:2021#table-21"
22
+ ref report-format "urn:oiml:pub:r:60-3:2021#table-22"
23
+ field conversion_factor_f : number {
24
+ label "Conversion Factor F"
25
+ unit "counts/v"
26
+ required true
27
+ bind sample.test_context.conversion_factor_f
28
+ targets { /req/electronic/disturbances }
29
+ }
30
+ field dmin_value : number {
31
+ label "Dmin Value"
32
+ unit "g, kg, or t"
33
+ bind sample.test_context.d_min
34
+ targets { /req/electronic/disturbances }
35
+ }
36
+ field discharge_types : object {
37
+ label "Discharge Types"
38
+ targets { /req/electronic/disturbances }
39
+ fields {
40
+ field contact_discharges : boolean {
41
+ label "Contact Discharges"
42
+ true_label "Yes"
43
+ false_label "No"
44
+ }
45
+ field paint_penetration : boolean {
46
+ label "Paint Penetration"
47
+ true_label "Yes"
48
+ false_label "No"
49
+ }
50
+ field air_discharges : boolean {
51
+ label "Air Discharges"
52
+ true_label "Yes"
53
+ false_label "No"
54
+ }
55
+ field polarity : enum {
56
+ label "Polarity"
57
+ values { positive { label "Positive" } negative { label "Negative" } }
58
+ }
59
+ }
60
+ }
61
+ field direct_application : array {
62
+ label "Direct Application"
63
+ description "Form 6.16.1 - direct application"
64
+ targets { /req/electronic/disturbances /req/electronic/no-significant-faults }
65
+ items { object fields {
66
+ field test_load : number {
67
+ label "Test Load"
68
+ unit "g, kg, or t"
69
+ }
70
+ field test_voltage_kv : number {
71
+ label "Test Voltage Kv"
72
+ unit "kV"
73
+ }
74
+ field no_of_discharges : integer {
75
+ label "No Of Discharges"
76
+ description ">= 10"
77
+ }
78
+ field repetition_interval_s : number {
79
+ label "Repetition Interval S"
80
+ unit "s"
81
+ }
82
+ field indication_without : number {
83
+ label "Indication Without Disturbance"
84
+ unit "counts"
85
+ measurement_method direct
86
+ }
87
+ field indication : number {
88
+ label "Indication"
89
+ unit "counts"
90
+ }
91
+ field difference : number {
92
+ label "Difference"
93
+ unit "v"
94
+ calculation "ocl{(indication - indication_without) / conversion_factor_f}"
95
+ }
96
+ field significant_fault : boolean {
97
+ label "Significant Fault"
98
+ true_label "Yes"
99
+ false_label "No"
100
+ calculation "ocl{abs(difference) > 1}"
101
+ }
102
+ field remarks : string {
103
+ label "Remarks"
104
+ }
105
+ } }
106
+ }
107
+ field horizontal_coupling_plane : array {
108
+ label "Horizontal Coupling Plane"
109
+ description "Form 6.16.2.1 - horizontal coupling plane"
110
+ targets { /req/electronic/disturbances /req/electronic/no-significant-faults }
111
+ items { object fields {
112
+ field test_load : number {
113
+ label "Test Load"
114
+ unit "g, kg, or t"
115
+ }
116
+ field test_voltage_kv : number {
117
+ label "Test Voltage Kv"
118
+ unit "kV"
119
+ }
120
+ field no_of_discharges : integer {
121
+ label "No Of Discharges"
122
+ }
123
+ field repetition_interval_s : number {
124
+ label "Repetition Interval S"
125
+ unit "s"
126
+ }
127
+ field indication_without : number {
128
+ label "Indication Without Disturbance"
129
+ unit "counts"
130
+ measurement_method direct
131
+ }
132
+ field indication : number {
133
+ label "Indication"
134
+ unit "counts"
135
+ }
136
+ field difference : number {
137
+ label "Difference"
138
+ unit "v"
139
+ calculation "ocl{(indication - indication_without) / conversion_factor_f}"
140
+ }
141
+ field significant_fault : boolean {
142
+ label "Significant Fault"
143
+ true_label "Yes"
144
+ false_label "No"
145
+ calculation "ocl{abs(difference) > 1}"
146
+ }
147
+ field remarks : string {
148
+ label "Remarks"
149
+ }
150
+ } }
151
+ }
152
+ field vertical_coupling_plane : array {
153
+ label "Vertical Coupling Plane"
154
+ description "Form 6.16.2.2 - vertical coupling plane"
155
+ targets { /req/electronic/disturbances /req/electronic/no-significant-faults }
156
+ items { object fields {
157
+ field test_load : number {
158
+ label "Test Load"
159
+ unit "g, kg, or t"
160
+ }
161
+ field test_voltage_kv : number {
162
+ label "Test Voltage Kv"
163
+ unit "kV"
164
+ }
165
+ field no_of_discharges : integer {
166
+ label "No Of Discharges"
167
+ }
168
+ field repetition_interval_s : number {
169
+ label "Repetition Interval S"
170
+ unit "s"
171
+ }
172
+ field indication_without : number {
173
+ label "Indication Without Disturbance"
174
+ unit "counts"
175
+ measurement_method direct
176
+ }
177
+ field indication : number {
178
+ label "Indication"
179
+ unit "counts"
180
+ }
181
+ field difference : number {
182
+ label "Difference"
183
+ unit "v"
184
+ calculation "ocl{(indication - indication_without) / conversion_factor_f}"
185
+ }
186
+ field significant_fault : boolean {
187
+ label "Significant Fault"
188
+ true_label "Yes"
189
+ false_label "No"
190
+ calculation "ocl{abs(difference) > 1}"
191
+ }
192
+ field remarks : string {
193
+ label "Remarks"
194
+ }
195
+ } }
196
+ }
197
+ field test_points : object {
198
+ label "Test Points"
199
+ description "Form 6.16.3 - specification of test points"
200
+ targets { /req/electronic/disturbances }
201
+ fields {
202
+ field direct_contact_discharges : text {
203
+ label "Direct Contact Discharges"
204
+ }
205
+ field direct_air_discharges : text {
206
+ label "Direct Air Discharges"
207
+ }
208
+ field indirect_application : text {
209
+ label "Indirect Application"
210
+ }
211
+ }
212
+ }
213
+ field remarks : text {
214
+ label "Remarks"
215
+ }
216
+ field overall_result : boolean {
217
+ label "Overall Result"
218
+ required true
219
+ true_label "Pass"
220
+ false_label "Fail"
221
+ }
222
+ pass_fail { criteria "No significant fault (> v_min)" pass_if "ocl{direct_application->forAll(r | not r.significant_fault) and horizontal_coupling_plane->forAll(r | not r.significant_fault) and vertical_coupling_plane->forAll(r | not r.significant_fault)}" }
223
+ }
224
+