@oimlsmart/primmel-packages 0.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (460) hide show
  1. package/AGENTS.md +60 -0
  2. package/LICENSE +21 -0
  3. package/README.md +68 -0
  4. package/acme-cgm-200/model/cgm200.prl +284 -0
  5. package/acme-cgm-200/model/r144-map.prl +337 -0
  6. package/acme-cgm-200/package.primmel +39 -0
  7. package/acme-cgm-system/model/cgm-system.prl +125 -0
  8. package/acme-cgm-system/model/r144-map.prl +75 -0
  9. package/acme-cgm-system/model/sample-line.prl +42 -0
  10. package/acme-cgm-system/package.primmel +23 -0
  11. package/acme-lc500/model/lc500.prl +218 -0
  12. package/acme-lc500/model/passport.prl +43 -0
  13. package/acme-lc500/model/r60-map.prl +161 -0
  14. package/acme-lc500/model/twin-cert-map.prl +114 -0
  15. package/acme-lc500/package.primmel +35 -0
  16. package/acme-md3xx/model/md350.prl +317 -0
  17. package/acme-md3xx/model/r129-map.prl +346 -0
  18. package/acme-md3xx/package.primmel +49 -0
  19. package/acme-rs180/model/r91-map.prl +234 -0
  20. package/acme-rs180/model/rs180.prl +236 -0
  21. package/acme-rs180/package.primmel +47 -0
  22. package/ims-demo/model/ims.prl +23 -0
  23. package/ims-demo/model/isms-map.prl +60 -0
  24. package/ims-demo/model/qms-map.prl +73 -0
  25. package/ims-demo/package.primmel +42 -0
  26. package/isms-ref/model/isms.prl +34 -0
  27. package/isms-ref/package.primmel +35 -0
  28. package/iso-iec-17000/package.primmel +8 -0
  29. package/iso-iec-17000/terminology.prl +268 -0
  30. package/iso-iec-17025/package.primmel +10 -0
  31. package/iso-iec-17025/specification/requirements/lab.prl +474 -0
  32. package/iso-iec-17025/terminology.prl +72 -0
  33. package/iso-iec-17065/package.primmel +10 -0
  34. package/iso-iec-17065/specification/requirements/body.prl +446 -0
  35. package/iso-iec-17065/terminology.prl +103 -0
  36. package/iso-iec-17067/package.primmel +10 -0
  37. package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
  38. package/iso-iec-17067/terminology.prl +24 -0
  39. package/oiml-cs/package.primmel +10 -0
  40. package/oiml-cs/specification/discrepancies.prl +26 -0
  41. package/oiml-cs/specification/requirements/cs.prl +515 -0
  42. package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
  43. package/oiml-cs-dataspace/package.primmel +9 -0
  44. package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
  45. package/oiml-cs-dataspace/specification/policies.prl +68 -0
  46. package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
  47. package/oiml-integrated-ref/package.primmel +10 -0
  48. package/oiml-r129/.primmel-allowlist.prl +2 -0
  49. package/oiml-r129/evaluation/processes.prl +152 -0
  50. package/oiml-r129/evaluation/workflow.prl +48 -0
  51. package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
  52. package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
  53. package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
  54. package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
  55. package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
  56. package/oiml-r129/execution/forms/admin/identification.prl +49 -0
  57. package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
  58. package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
  59. package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
  60. package/oiml-r129/execution/forms/emc/esd.prl +66 -0
  61. package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
  62. package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
  63. package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
  64. package/oiml-r129/execution/forms/emc/surge.prl +61 -0
  65. package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
  66. package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
  67. package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
  68. package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
  69. package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
  70. package/oiml-r129/execution/forms/shared/headers.prl +86 -0
  71. package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
  72. package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
  73. package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
  74. package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
  75. package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
  76. package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
  77. package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
  78. package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
  79. package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
  80. package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
  81. package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
  82. package/oiml-r129/layers.prl +50 -0
  83. package/oiml-r129/model/attributes.prl +243 -0
  84. package/oiml-r129/model/behaviors.prl +79 -0
  85. package/oiml-r129/model/capabilities.prl +29 -0
  86. package/oiml-r129/model/characteristics.prl +8 -0
  87. package/oiml-r129/model/conditions.prl +23 -0
  88. package/oiml-r129/model/instrument.prl +67 -0
  89. package/oiml-r129/model/state.prl +22 -0
  90. package/oiml-r129/model/twin.prl +23 -0
  91. package/oiml-r129/package.primmel +15 -0
  92. package/oiml-r129/payload/application.yaml +40 -0
  93. package/oiml-r129/payload/conditions-common-test.yaml +8 -0
  94. package/oiml-r129/payload/formulas-variants.yaml +33 -0
  95. package/oiml-r129/payload/promises.yaml +102 -0
  96. package/oiml-r129/payload/sample-data.yaml +300 -0
  97. package/oiml-r129/references.prl +306 -0
  98. package/oiml-r129/sources-prd/coverage.json +59 -0
  99. package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
  100. package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
  101. package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
  102. package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
  103. package/oiml-r129/specification/calculations.prl +83 -0
  104. package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
  105. package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
  106. package/oiml-r129/specification/conformance/examinations.prl +83 -0
  107. package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
  108. package/oiml-r129/specification/formulas.prl +9 -0
  109. package/oiml-r129/specification/requirements/electronic.prl +46 -0
  110. package/oiml-r129/specification/requirements/metrological.prl +83 -0
  111. package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
  112. package/oiml-r129/specification/requirements/software.prl +57 -0
  113. package/oiml-r129/specification/requirements/technical.prl +134 -0
  114. package/oiml-r129/specification/symbols.prl +187 -0
  115. package/oiml-r129/specification/tables.prl +74 -0
  116. package/oiml-r129/terminology.prl +415 -0
  117. package/oiml-r129/value-types.prl +40 -0
  118. package/oiml-r144/.primmel-allowlist.prl +2 -0
  119. package/oiml-r144/entities/instrument.prl +360 -0
  120. package/oiml-r144/entities/test-execution.prl +228 -0
  121. package/oiml-r144/entities/workflow.prl +2075 -0
  122. package/oiml-r144/evaluation/processes.prl +152 -0
  123. package/oiml-r144/evaluation/workflow.prl +48 -0
  124. package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
  125. package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
  126. package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
  127. package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
  128. package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
  129. package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
  130. package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
  131. package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
  132. package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
  133. package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
  134. package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
  135. package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
  136. package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
  137. package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
  138. package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
  139. package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
  140. package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
  141. package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
  142. package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
  143. package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
  144. package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
  145. package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
  146. package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
  147. package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
  148. package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
  149. package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
  150. package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
  151. package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
  152. package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
  153. package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
  154. package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
  155. package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
  156. package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
  157. package/oiml-r144/execution/forms/shared/headers.prl +132 -0
  158. package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
  159. package/oiml-r144/layers.prl +44 -0
  160. package/oiml-r144/model/attributes.prl +679 -0
  161. package/oiml-r144/model/behaviors.prl +117 -0
  162. package/oiml-r144/model/capabilities.prl +99 -0
  163. package/oiml-r144/model/characteristics.prl +27 -0
  164. package/oiml-r144/model/conditions.prl +46 -0
  165. package/oiml-r144/model/instrument.prl +85 -0
  166. package/oiml-r144/model/state.prl +18 -0
  167. package/oiml-r144/model/twin.prl +25 -0
  168. package/oiml-r144/package.primmel +15 -0
  169. package/oiml-r144/payload/application.yaml +80 -0
  170. package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
  171. package/oiml-r144/payload/conditions-common-test.yaml +74 -0
  172. package/oiml-r144/payload/formulas-variants.yaml +32 -0
  173. package/oiml-r144/payload/promises.yaml +118 -0
  174. package/oiml-r144/payload/sample-data.yaml +643 -0
  175. package/oiml-r144/references.prl +594 -0
  176. package/oiml-r144/sources-prd/coverage.json +114 -0
  177. package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
  178. package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
  179. package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
  180. package/oiml-r144/specification/calculations.prl +123 -0
  181. package/oiml-r144/specification/conformance/examination.prl +87 -0
  182. package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
  183. package/oiml-r144/specification/formulas.prl +37 -0
  184. package/oiml-r144/specification/reference-materials.prl +87 -0
  185. package/oiml-r144/specification/requirements/controls.prl +51 -0
  186. package/oiml-r144/specification/requirements/metrological.prl +299 -0
  187. package/oiml-r144/specification/requirements/report.prl +35 -0
  188. package/oiml-r144/specification/requirements/technical.prl +455 -0
  189. package/oiml-r144/specification/symbols.prl +357 -0
  190. package/oiml-r144/specification/tables.prl +95 -0
  191. package/oiml-r144/specification/test-point-sets.prl +15 -0
  192. package/oiml-r144/terminology.prl +308 -0
  193. package/oiml-r144/value-types.prl +49 -0
  194. package/oiml-r60/.primmel-allowlist.prl +2 -0
  195. package/oiml-r60/entities/workflow.prl +2079 -0
  196. package/oiml-r60/evaluation/processes.prl +152 -0
  197. package/oiml-r60/evaluation/workflow.prl +48 -0
  198. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
  199. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
  200. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
  201. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
  202. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
  203. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
  204. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
  205. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
  206. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
  207. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
  208. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
  209. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
  210. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
  211. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
  212. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
  213. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
  214. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
  215. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
  216. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
  217. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
  218. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
  219. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
  220. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
  221. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
  222. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
  223. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
  224. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
  225. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
  226. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
  227. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
  228. package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
  229. package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
  230. package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
  231. package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
  232. package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
  233. package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
  234. package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
  235. package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
  236. package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
  237. package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
  238. package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
  239. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
  240. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
  241. package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
  242. package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
  243. package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
  244. package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
  245. package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
  246. package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
  247. package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
  248. package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
  249. package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
  250. package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
  251. package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
  252. package/oiml-r60/execution/forms/shared/headers.prl +255 -0
  253. package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
  254. package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
  255. package/oiml-r60/layers.prl +46 -0
  256. package/oiml-r60/model/attributes.prl +642 -0
  257. package/oiml-r60/model/behaviors.prl +165 -0
  258. package/oiml-r60/model/capabilities.prl +57 -0
  259. package/oiml-r60/model/characteristics.prl +27 -0
  260. package/oiml-r60/model/conditions.prl +50 -0
  261. package/oiml-r60/model/instrument.prl +96 -0
  262. package/oiml-r60/model/processes.prl +54 -0
  263. package/oiml-r60/model/state.prl +22 -0
  264. package/oiml-r60/model/twin.prl +16 -0
  265. package/oiml-r60/package.primmel +16 -0
  266. package/oiml-r60/payload/annexes-part4.yaml +122 -0
  267. package/oiml-r60/payload/application.yaml +83 -0
  268. package/oiml-r60/payload/conditions-common-test.yaml +121 -0
  269. package/oiml-r60/payload/formulas-variants.yaml +55 -0
  270. package/oiml-r60/payload/promises.yaml +224 -0
  271. package/oiml-r60/payload/sample-data.yaml +5025 -0
  272. package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
  273. package/oiml-r60/references.prl +549 -0
  274. package/oiml-r60/sources-prd/coverage.json +740 -0
  275. package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
  276. package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
  277. package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
  278. package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
  279. package/oiml-r60/specification/calculations.prl +318 -0
  280. package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
  281. package/oiml-r60/specification/conformance/electronic.prl +483 -0
  282. package/oiml-r60/specification/conformance/examination.prl +183 -0
  283. package/oiml-r60/specification/conformance/metrological.prl +478 -0
  284. package/oiml-r60/specification/constraints.prl +58 -0
  285. package/oiml-r60/specification/formulas-used.prl +43 -0
  286. package/oiml-r60/specification/formulas.prl +20 -0
  287. package/oiml-r60/specification/requirements/class-specific.prl +655 -0
  288. package/oiml-r60/specification/requirements/classification.prl +114 -0
  289. package/oiml-r60/specification/requirements/electronic.prl +222 -0
  290. package/oiml-r60/specification/requirements/metrological.prl +381 -0
  291. package/oiml-r60/specification/requirements/technical.prl +146 -0
  292. package/oiml-r60/specification/symbols.prl +599 -0
  293. package/oiml-r60/specification/tables.prl +182 -0
  294. package/oiml-r60/specification/test-sequences.prl +72 -0
  295. package/oiml-r60/terminology.prl +920 -0
  296. package/oiml-r60/value-types.prl +46 -0
  297. package/oiml-r91/.primmel-allowlist.prl +3 -0
  298. package/oiml-r91/entities/instrument.prl +359 -0
  299. package/oiml-r91/entities/workflow.prl +2075 -0
  300. package/oiml-r91/evaluation/processes.prl +152 -0
  301. package/oiml-r91/evaluation/workflow.prl +48 -0
  302. package/oiml-r91/execution/forms/evidence-file.prl +41 -0
  303. package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
  304. package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
  305. package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
  306. package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
  307. package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
  308. package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
  309. package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
  310. package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
  311. package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
  312. package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
  313. package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
  314. package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
  315. package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
  316. package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
  317. package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
  318. package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
  319. package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
  320. package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
  321. package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
  322. package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
  323. package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
  324. package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
  325. package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
  326. package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
  327. package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
  328. package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
  329. package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
  330. package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
  331. package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
  332. package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
  333. package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
  334. package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
  335. package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
  336. package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
  337. package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
  338. package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
  339. package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
  340. package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
  341. package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
  342. package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
  343. package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
  344. package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
  345. package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
  346. package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
  347. package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
  348. package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
  349. package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
  350. package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
  351. package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
  352. package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
  353. package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
  354. package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
  355. package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
  356. package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
  357. package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
  358. package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
  359. package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
  360. package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
  361. package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
  362. package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
  363. package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
  364. package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
  365. package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
  366. package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
  367. package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
  368. package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
  369. package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
  370. package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
  371. package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
  372. package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
  373. package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
  374. package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
  375. package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
  376. package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
  377. package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
  378. package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
  379. package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
  380. package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
  381. package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
  382. package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
  383. package/oiml-r91/layers.prl +46 -0
  384. package/oiml-r91/model/artifacts.prl +29 -0
  385. package/oiml-r91/model/attributes.prl +698 -0
  386. package/oiml-r91/model/behaviors.prl +142 -0
  387. package/oiml-r91/model/capabilities.prl +88 -0
  388. package/oiml-r91/model/characteristics.prl +27 -0
  389. package/oiml-r91/model/conditions.prl +37 -0
  390. package/oiml-r91/model/instrument.prl +147 -0
  391. package/oiml-r91/model/state.prl +22 -0
  392. package/oiml-r91/model/twin.prl +17 -0
  393. package/oiml-r91/package.primmel +14 -0
  394. package/oiml-r91/payload/application.yaml +201 -0
  395. package/oiml-r91/payload/conditions-common-test.yaml +19 -0
  396. package/oiml-r91/payload/promises.yaml +142 -0
  397. package/oiml-r91/payload/sample-data.yaml +464 -0
  398. package/oiml-r91/references.prl +72 -0
  399. package/oiml-r91/sources-prd/coverage.json +106 -0
  400. package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
  401. package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
  402. package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
  403. package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
  404. package/oiml-r91/specification/calculations.prl +26 -0
  405. package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
  406. package/oiml-r91/specification/conformance/metrological.prl +906 -0
  407. package/oiml-r91/specification/formulas.prl +10 -0
  408. package/oiml-r91/specification/requirements/class-specific.prl +308 -0
  409. package/oiml-r91/specification/requirements/metrological.prl +176 -0
  410. package/oiml-r91/specification/requirements/technical.prl +173 -0
  411. package/oiml-r91/specification/symbols.prl +323 -0
  412. package/oiml-r91/specification/tables.prl +136 -0
  413. package/oiml-r91/terminology.prl +535 -0
  414. package/oiml-r91/value-types.prl +26 -0
  415. package/oiml-smart-core/entities/comments.prl +101 -0
  416. package/oiml-smart-core/entities/cs-operations.prl +492 -0
  417. package/oiml-smart-core/entities/cs-participants.prl +470 -0
  418. package/oiml-smart-core/entities/engagement.prl +323 -0
  419. package/oiml-smart-core/entities/instrument.prl +359 -0
  420. package/oiml-smart-core/entities/module-b.prl +214 -0
  421. package/oiml-smart-core/entities/operated-schemes.prl +141 -0
  422. package/oiml-smart-core/entities/parties.prl +429 -0
  423. package/oiml-smart-core/entities/payment-records.prl +92 -0
  424. package/oiml-smart-core/entities/verification.prl +187 -0
  425. package/oiml-smart-core/entities/workflow.prl +2075 -0
  426. package/oiml-smart-core/evaluation/roles.prl +65 -0
  427. package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
  428. package/oiml-smart-core/package.primmel +10 -0
  429. package/oiml-smart-core/specification/competence-kinds.prl +64 -0
  430. package/oiml-smart-core/specification/constraints.prl +40 -0
  431. package/oiml-smart-core/specification/invariants.prl +90 -0
  432. package/oiml-smart-core/specification/predicates.prl +116 -0
  433. package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
  434. package/oiml-smart-module-env-iec60068/package.primmel +10 -0
  435. package/oiml-smart-module-examination-docs/package.primmel +10 -0
  436. package/oiml-smart-module-reference-materials/package.primmel +10 -0
  437. package/oiml-smart-module-report-headers/package.primmel +10 -0
  438. package/oiml-smart-module-software-d31/package.primmel +10 -0
  439. package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
  440. package/oiml-smart-module-specimen-governance/package.primmel +10 -0
  441. package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
  442. package/oiml-twin-cert/evaluation/roles.prl +15 -0
  443. package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
  444. package/oiml-twin-cert/execution/forms/probe.prl +99 -0
  445. package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
  446. package/oiml-twin-cert/model/attributes.prl +243 -0
  447. package/oiml-twin-cert/model/behaviors.prl +8 -0
  448. package/oiml-twin-cert/model/characteristics.prl +18 -0
  449. package/oiml-twin-cert/model/monitors.prl +16 -0
  450. package/oiml-twin-cert/package.primmel +16 -0
  451. package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
  452. package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
  453. package/oiml-twin-cert/specification/symbols.prl +36 -0
  454. package/oiml-twin-cert/terminology.prl +8 -0
  455. package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
  456. package/package.json +17 -0
  457. package/qms-ref/model/qms.prl +31 -0
  458. package/qms-ref/package.primmel +38 -0
  459. package/quarry-belt-scale/model/ops.prl +115 -0
  460. package/quarry-belt-scale/package.primmel +36 -0
@@ -0,0 +1,4212 @@
1
+ {
2
+ "prd_sentences": "0.1.0",
3
+ "document": {
4
+ "urn": "urn:oiml:pub:r:60-3:2021",
5
+ "short": "OIML R 60-3:2021",
6
+ "part": "3"
7
+ },
8
+ "sentences": [
9
+ {
10
+ "address": "clause-1.1/s1",
11
+ "fragment": "clause-1.1",
12
+ "clause": "1.1",
13
+ "kind": "provision",
14
+ "fragment_normative": true,
15
+ "modality": "informative",
16
+ "text": "This Report Format applies to any kind of load cell (independent of its technology)."
17
+ },
18
+ {
19
+ "address": "clause-1.1/s2",
20
+ "fragment": "clause-1.1",
21
+ "clause": "1.1",
22
+ "kind": "provision",
23
+ "fragment_normative": true,
24
+ "modality": "normative",
25
+ "text": "It presents a standardised format for the results of the various tests and examinations, described in OIML R 60-2, to which a type of load cell shall be submitted for the purpose of its approval based on this OIML Recommendation."
26
+ },
27
+ {
28
+ "address": "clause-1.2/s1",
29
+ "fragment": "clause-1.2",
30
+ "clause": "1.2",
31
+ "kind": "provision",
32
+ "fragment_normative": true,
33
+ "modality": "informative",
34
+ "text": "It is recommended that all metrology services or laboratories evaluating and/or testing types of load cells according to OIML R 60-1, or to national or regional regulations based on this Recommendation, use this Report Format, directly or after translation into a language other than English or French."
35
+ },
36
+ {
37
+ "address": "clause-1.2/s2",
38
+ "fragment": "clause-1.2",
39
+ "clause": "1.2",
40
+ "kind": "provision",
41
+ "fragment_normative": true,
42
+ "modality": "informative",
43
+ "text": "In the case of a translation, it is highly recommended to leave the structure and the numbers of the clauses unchanged: in this case, most of the content is also understandable for those who cannot read the language of the translation."
44
+ },
45
+ {
46
+ "address": "clause-1.3/s1",
47
+ "fragment": "clause-1.3",
48
+ "clause": "1.3",
49
+ "kind": "provision",
50
+ "fragment_normative": true,
51
+ "modality": "normative",
52
+ "text": "Some of the tests may have to be repeated several times and reported using several identical sheets; therefore, report pages must be numbered in the space provided at the top of each page, completed by the indication of the total number of pages."
53
+ },
54
+ {
55
+ "address": "clause-1.4/s1",
56
+ "fragment": "clause-1.4",
57
+ "clause": "1.4",
58
+ "kind": "provision",
59
+ "fragment_normative": true,
60
+ "modality": "normative",
61
+ "text": "In the practical application of the Report Format, in addition to a cover page by the Issuing Authority, as a minimum, clauses A-F (as necessary) shall be included."
62
+ },
63
+ {
64
+ "address": "clause-2/s1",
65
+ "fragment": "clause-2",
66
+ "clause": "2",
67
+ "kind": "provision",
68
+ "fragment_normative": true,
69
+ "modality": "informative",
70
+ "text": "In the framework of OIML B 18 Framework for the OIML Certification System (OIML-CS) [6] applicable to load cells in conformity with OIML R 60-1 and R 60-2, use of this Report Format is mandatory, in French and/or in English with translation into the national languages of the countries issuing such certificates, if appropriate."
71
+ },
72
+ {
73
+ "address": "clause-2/s2",
74
+ "fragment": "clause-2",
75
+ "clause": "2",
76
+ "kind": "provision",
77
+ "fragment_normative": true,
78
+ "modality": "informative",
79
+ "text": "Implementation of this Report Format is informative with regard to the implementation of OIML R 60-1 and R 60-2 in national regulations."
80
+ },
81
+ {
82
+ "address": "clause-2.1.1/s1",
83
+ "fragment": "clause-2.1.1",
84
+ "clause": "2.1.1",
85
+ "kind": "provision",
86
+ "fragment_normative": true,
87
+ "modality": "informative",
88
+ "text": "In order to facilitate a comparison of the reports established in English and in French, the same abbreviations (those of the English language) are used in both versions; the meanings of these abbreviations are given whenever appropriate."
89
+ },
90
+ {
91
+ "address": "clause-2.1.1/s2",
92
+ "fragment": "clause-2.1.1",
93
+ "clause": "2.1.1",
94
+ "kind": "provision",
95
+ "fragment_normative": true,
96
+ "modality": "informative",
97
+ "text": "In testing and evaluating load cells for type evaluation, it is recognised that the test apparatus and practices used by the various laboratories will be different."
98
+ },
99
+ {
100
+ "address": "clause-2.1.1/s3",
101
+ "fragment": "clause-2.1.1",
102
+ "clause": "2.1.1",
103
+ "kind": "provision",
104
+ "fragment_normative": true,
105
+ "modality": "informative",
106
+ "text": "OIML R 60 allows for these variations and still provides a method for testing, recording and calculating results that are readily understandable by other knowledgeable parties reviewing the data."
107
+ },
108
+ {
109
+ "address": "clause-2.1.1/s4",
110
+ "fragment": "clause-2.1.1",
111
+ "clause": "2.1.1",
112
+ "kind": "provision",
113
+ "fragment_normative": true,
114
+ "modality": "informative",
115
+ "text": "In order to achieve this ease of comparability it is necessary that those persons conducting the tests use a common system for recording data and calculating results."
116
+ },
117
+ {
118
+ "address": "clause-2.1.1/s5",
119
+ "fragment": "clause-2.1.1",
120
+ "clause": "2.1.1",
121
+ "kind": "provision",
122
+ "fragment_normative": true,
123
+ "modality": "informative",
124
+ "text": "Thus, it is essential that the calculation procedures below be reviewed and followed closely in the completion of this test report."
125
+ },
126
+ {
127
+ "address": "clause-2.1.2.1/s1",
128
+ "fragment": "clause-2.1.2.1",
129
+ "clause": "2.1.2.1",
130
+ "kind": "provision",
131
+ "fragment_normative": true,
132
+ "modality": "informative",
133
+ "text": "Complete a table-6.3 for each test temperature, calculate the averages and record in the right-hand column."
134
+ },
135
+ {
136
+ "address": "clause-2.1.2.1/s2",
137
+ "fragment": "clause-2.1.2.1",
138
+ "clause": "2.1.2.1",
139
+ "kind": "provision",
140
+ "fragment_normative": true,
141
+ "modality": "informative",
142
+ "text": "When five runs are necessary, use table-6.4."
143
+ },
144
+ {
145
+ "address": "clause-2.1.2.2/s1",
146
+ "fragment": "clause-2.1.2.2",
147
+ "clause": "2.1.2.2",
148
+ "kind": "provision",
149
+ "fragment_normative": true,
150
+ "modality": "informative",
151
+ "text": "Determine the conversion factor, f, which is the number of indicated units per load cell verification interval, v, and is used to convert all “indicated units” to “v”."
152
+ },
153
+ {
154
+ "address": "clause-2.1.2.2/s2",
155
+ "fragment": "clause-2.1.2.2",
156
+ "clause": "2.1.2.2",
157
+ "kind": "provision",
158
+ "fragment_normative": true,
159
+ "modality": "informative",
160
+ "text": "It is determined from the test data averages of the increasing load tests at the initial 20 \"unitsml(degC)\" nominal test temperature."
161
+ },
162
+ {
163
+ "address": "clause-2.1.2.3/s1",
164
+ "fragment": "clause-2.1.2.3",
165
+ "clause": "2.1.2.3",
166
+ "kind": "provision",
167
+ "fragment_normative": true,
168
+ "modality": "informative",
169
+ "text": "If a test load corresponding to 75 % of the measuring range for the load cell under test (i.e. 2250 divisions for a 3000 division cell, which is D_{\"min\"} plus 75 % of the difference between D_{\"max\"} and D_{\"min\"}) is not included in the test loads used in table-6.3, interpolate between the adjacent upper and lower values of the averages of all three test runs and record in table-6.5 (see R 60-2, 2.8.2)."
170
+ },
171
+ {
172
+ "address": "clause-2.1.2.4/s1",
173
+ "fragment": "clause-2.1.2.4",
174
+ "clause": "2.1.2.4",
175
+ "kind": "provision",
176
+ "fragment_normative": true,
177
+ "modality": "informative",
178
+ "text": "Calculate the difference between the average indication on the increasing load test runs at 75 % of the difference between D_{\"max\"} and D_{\"min\"} and the indication at D_{\"min\"}."
179
+ },
180
+ {
181
+ "address": "clause-2.1.2.4/s2",
182
+ "fragment": "clause-2.1.2.4",
183
+ "clause": "2.1.2.4",
184
+ "kind": "provision",
185
+ "fragment_normative": true,
186
+ "modality": "informative",
187
+ "text": "Divide the result (to five significant figures) by the number of verification intervals (75 % of n) for that load to obtain the conversion factor, f, and record in the tables that follow."
188
+ },
189
+ {
190
+ "address": "clause-2.1.2.4/s3",
191
+ "fragment": "clause-2.1.2.4",
192
+ "clause": "2.1.2.4",
193
+ "kind": "provision",
194
+ "fragment_normative": true,
195
+ "modality": "informative",
196
+ "text": "f = {\"average indication at\" quad 0.75 cdot (D_{\"max\"} - D_{\"min\"}) - \"indication at\" quad D_{\"min\"}} / {0.75 cdot n}"
197
+ },
198
+ {
199
+ "address": "clause-2.1.2.4/s4",
200
+ "fragment": "clause-2.1.2.4",
201
+ "clause": "2.1.2.4",
202
+ "kind": "provision",
203
+ "fragment_normative": true,
204
+ "modality": "informative",
205
+ "text": "The units of conversion factor, f, are indicated units (e.g. digits or counts) per load cell verification interval, v."
206
+ },
207
+ {
208
+ "address": "clause-2.1.2.5/s1",
209
+ "fragment": "clause-2.1.2.5",
210
+ "clause": "2.1.2.5",
211
+ "kind": "provision",
212
+ "fragment_normative": true,
213
+ "modality": "informative",
214
+ "text": "Enter the average test indications of the tests at the temperatures following the initial test at a nominal 20 \"unitsml(degC)\" in table-6.5."
215
+ },
216
+ {
217
+ "address": "clause-2.1.2.5/s2",
218
+ "fragment": "clause-2.1.2.5",
219
+ "clause": "2.1.2.5",
220
+ "kind": "provision",
221
+ "fragment_normative": true,
222
+ "modality": "informative",
223
+ "text": "In recording this data, indicate a “no test load” indication (at D_{\"min\"}) as “0”."
224
+ },
225
+ {
226
+ "address": "clause-2.1.2.5/s3",
227
+ "fragment": "clause-2.1.2.5",
228
+ "clause": "2.1.2.5",
229
+ "kind": "provision",
230
+ "fragment_normative": true,
231
+ "modality": "normative",
232
+ "text": "This may require subtracting the “no load indication at D_{\"min\"}” from the “test load indication” so that the first entry in the column is “0”."
233
+ },
234
+ {
235
+ "address": "clause-2.1.2.5/s4",
236
+ "fragment": "clause-2.1.2.5",
237
+ "clause": "2.1.2.5",
238
+ "kind": "provision",
239
+ "fragment_normative": true,
240
+ "modality": "informative",
241
+ "text": "These “0’s” have been preprinted on the form to clarify that a dead load condition is recorded as “0”."
242
+ },
243
+ {
244
+ "address": "clause-2.1.2.6/s1",
245
+ "fragment": "clause-2.1.2.6",
246
+ "clause": "2.1.2.6",
247
+ "kind": "provision",
248
+ "fragment_normative": true,
249
+ "modality": "informative",
250
+ "text": "Calculate the reference indication, R_{\"i\"}, by converting the net test load, in mass units, to indicated units (e.g. counts or digits), by multiplying by the conversion factor, f, for each test load and recording in the 2nd column in table-6.5."
251
+ },
252
+ {
253
+ "address": "clause-2.1.2.6/s2",
254
+ "fragment": "clause-2.1.2.6",
255
+ "clause": "2.1.2.6",
256
+ "kind": "provision",
257
+ "fragment_normative": true,
258
+ "modality": "informative",
259
+ "text": "R_i = {(\"test load\" quad i - D_{\"min\"})} / {(D_{\"max\"} - D_{\"min\"})} cdot n cdot f"
260
+ },
261
+ {
262
+ "address": "clause-2.1.2.7/s1",
263
+ "fragment": "clause-2.1.2.7",
264
+ "clause": "2.1.2.7",
265
+ "kind": "provision",
266
+ "fragment_normative": true,
267
+ "modality": "informative",
268
+ "text": "In table-6.5 calculate the difference between the average test indication and the reference indication for each test load at each test temperature and divide the result by the conversion factor, f, to obtain the error, E_{\"L\"}, for each test load in terms of v."
269
+ },
270
+ {
271
+ "address": "clause-2.1.2.7/s2",
272
+ "fragment": "clause-2.1.2.7",
273
+ "clause": "2.1.2.7",
274
+ "kind": "provision",
275
+ "fragment_normative": true,
276
+ "modality": "informative",
277
+ "text": "E_L = (\"average test indication for test load\" quad i - \"reference indication\" quad R_i) // f"
278
+ },
279
+ {
280
+ "address": "clause-2.1.2.8/s1",
281
+ "fragment": "clause-2.1.2.8",
282
+ "clause": "2.1.2.8",
283
+ "kind": "provision",
284
+ "fragment_normative": true,
285
+ "modality": "informative",
286
+ "text": "Compare E_{\"L\"} with the corresponding MPE for each test load."
287
+ },
288
+ {
289
+ "address": "clause-2.1.3.1/s1",
290
+ "fragment": "clause-2.1.3.1",
291
+ "clause": "2.1.3.1",
292
+ "kind": "provision",
293
+ "fragment_normative": true,
294
+ "modality": "informative",
295
+ "text": "Enter data in table-6.6."
296
+ },
297
+ {
298
+ "address": "clause-2.1.3.2/s1",
299
+ "fragment": "clause-2.1.3.2",
300
+ "clause": "2.1.3.2",
301
+ "kind": "provision",
302
+ "fragment_normative": true,
303
+ "modality": "informative",
304
+ "text": "Calculate the maximum difference between the test indications on form-6.3 and divide it by f to obtain the repeatability error, E_{\"R\"}, in terms of the load cell verification interval, v."
305
+ },
306
+ {
307
+ "address": "clause-2.1.3.2/s2",
308
+ "fragment": "clause-2.1.3.2",
309
+ "clause": "2.1.3.2",
310
+ "kind": "provision",
311
+ "fragment_normative": true,
312
+ "modality": "informative",
313
+ "text": "E_R = (\"maximum indication of the test load\" - \"minimum indication\") // f"
314
+ },
315
+ {
316
+ "address": "clause-2.1.3.3/s1",
317
+ "fragment": "clause-2.1.3.3",
318
+ "clause": "2.1.3.3",
319
+ "kind": "provision",
320
+ "fragment_normative": true,
321
+ "modality": "informative",
322
+ "text": "Compare E_{\"R\"} with the absolute value of the corresponding MPE for each test load."
323
+ },
324
+ {
325
+ "address": "clause-2.1.4.1/s1",
326
+ "fragment": "clause-2.1.4.1",
327
+ "clause": "2.1.4.1",
328
+ "kind": "provision",
329
+ "fragment_normative": true,
330
+ "modality": "informative",
331
+ "text": "Enter in table-6.7 the average indication for the initial minimum test load, D_{\"min\"}, for each test temperature from table-6.3."
332
+ },
333
+ {
334
+ "address": "clause-2.1.4.2/s1",
335
+ "fragment": "clause-2.1.4.2",
336
+ "clause": "2.1.4.2",
337
+ "kind": "provision",
338
+ "fragment_normative": true,
339
+ "modality": "informative",
340
+ "text": "Calculate the difference between the average test indications for each temperature T_{\"i\"} in sequence and divide the result by the conversion factor, f, to obtain the change in terms of the load cell verification interval, v."
341
+ },
342
+ {
343
+ "address": "clause-2.1.4.2/s2",
344
+ "fragment": "clause-2.1.4.2",
345
+ "clause": "2.1.4.2",
346
+ "kind": "provision",
347
+ "fragment_normative": true,
348
+ "modality": "informative",
349
+ "text": "C_{\"M\"} = (\"average test indication at\" quad T_2 - \"average indication at\" quad T_1) // f"
350
+ },
351
+ {
352
+ "address": "clause-2.1.4.3/s1",
353
+ "fragment": "clause-2.1.4.3",
354
+ "clause": "2.1.4.3",
355
+ "kind": "provision",
356
+ "fragment_normative": true,
357
+ "modality": "informative",
358
+ "text": "Divide C_{\"M\"} by (T_2 - T_1) and multiply the result by a factor T_{\"f\"} = 5 for class B, C, and D load cells or T_{\"f\"} = 2 for class A load cells."
359
+ },
360
+ {
361
+ "address": "clause-2.1.4.3/s2",
362
+ "fragment": "clause-2.1.4.3",
363
+ "clause": "2.1.4.3",
364
+ "kind": "provision",
365
+ "fragment_normative": true,
366
+ "modality": "informative",
367
+ "text": "This gives the change in v per 5 \"unitsml(degC)\" for class B, C, and D load cells or in v per 2 \"unitsml(degC)\" for class A load cells."
368
+ },
369
+ {
370
+ "address": "clause-2.1.4.4/s1",
371
+ "fragment": "clause-2.1.4.4",
372
+ "clause": "2.1.4.4",
373
+ "kind": "provision",
374
+ "fragment_normative": true,
375
+ "modality": "informative",
376
+ "text": "Multiply the result by [(D_{\"max\"} - D_{\"min\"}) // n // v_{\"min\"}] to give the final result C_{\"M\"}( v_{\"min\"}) in units of v_{\"min\"} per 5 \"unitsml(degC)\" for class B, C, and D load cells, or in units of v_{\"min\"} per 2 \"unitsml(degC)\" for class A load cells."
377
+ },
378
+ {
379
+ "address": "clause-2.1.4.4/s2",
380
+ "fragment": "clause-2.1.4.4",
381
+ "clause": "2.1.4.4",
382
+ "kind": "provision",
383
+ "fragment_normative": true,
384
+ "modality": "normative",
385
+ "text": "C_{\"M\"}(v_{\"min\"}) must not exceed p_{\"LC\"}."
386
+ },
387
+ {
388
+ "address": "clause-2.1.4.4/s3",
389
+ "fragment": "clause-2.1.4.4",
390
+ "clause": "2.1.4.4",
391
+ "kind": "provision",
392
+ "fragment_normative": true,
393
+ "modality": "informative",
394
+ "text": "bb(C_M(v_{\"min\"}) = | {C_M cdot T_f}/{(T_2 - T_1)} xx {(D_{\"max\"} - D_{\"min\"})} / {n cdot v_{\"min\"}} |)"
395
+ },
396
+ {
397
+ "address": "clause-2.1.4.4/s4",
398
+ "fragment": "clause-2.1.4.4",
399
+ "clause": "2.1.4.4",
400
+ "kind": "provision",
401
+ "fragment_normative": true,
402
+ "modality": "informative",
403
+ "text": "C_M(v_{\"min\"}) <= p_{LC}"
404
+ },
405
+ {
406
+ "address": "clause-2.1.5/s1",
407
+ "fragment": "clause-2.1.5",
408
+ "clause": "2.1.5",
409
+ "kind": "provision",
410
+ "fragment_normative": true,
411
+ "modality": "informative",
412
+ "text": "(C_C(t) = Creep, expressed in terms of the load cell verification interval, v)"
413
+ },
414
+ {
415
+ "address": "clause-2.1.5/s2",
416
+ "fragment": "clause-2.1.5",
417
+ "clause": "2.1.5",
418
+ "kind": "provision",
419
+ "fragment_normative": true,
420
+ "modality": "informative",
421
+ "text": "(C_DR = DR, expressed in terms of the load cell verification interval, v)"
422
+ },
423
+ {
424
+ "address": "clause-2.1.5/s3",
425
+ "fragment": "clause-2.1.5",
426
+ "clause": "2.1.5",
427
+ "kind": "provision",
428
+ "fragment_normative": true,
429
+ "modality": "informative",
430
+ "text": "Remark: Contrary to the minimum dead load output return DR in terms of mass the minimum dead load output C_DR is expressed in terms of the verification interval, v."
431
+ },
432
+ {
433
+ "address": "clause-2.1.5/s4",
434
+ "fragment": "clause-2.1.5",
435
+ "clause": "2.1.5",
436
+ "kind": "provision",
437
+ "fragment_normative": true,
438
+ "modality": "informative",
439
+ "text": "From the test indications recorded in table-6.8, calculate the difference between the initial indication obtained at the minimum creep test load after the stabilisation period and any indication obtained over the 30 minute test period with the maximum creep test load of 90 % to 100 % of E_{\"max\"} and divide by the conversion factor, f."
440
+ },
441
+ {
442
+ "address": "clause-2.1.5/s5",
443
+ "fragment": "clause-2.1.5",
444
+ "clause": "2.1.5",
445
+ "kind": "provision",
446
+ "fragment_normative": true,
447
+ "modality": "informative",
448
+ "text": "C_C (t) = (\"indication\" - \"initial indication\") // f"
449
+ },
450
+ {
451
+ "address": "clause-2.1.5/s6",
452
+ "fragment": "clause-2.1.5",
453
+ "clause": "2.1.5",
454
+ "kind": "provision",
455
+ "fragment_normative": true,
456
+ "modality": "normative",
457
+ "text": "Remark: If the minimum creep test load or the maximum creep test load differ from D_{\"min\"} or D_{\"max\"} according to 2.1.2 “Load cell errors E_{\"L\"}” the conversion factor, f, must be recalculated with the minimum and maximum creep test loads (see 2.1.2.4)."
458
+ },
459
+ {
460
+ "address": "clause-2.1.5.1/s1",
461
+ "fragment": "clause-2.1.5.1",
462
+ "clause": "2.1.5.1",
463
+ "kind": "provision",
464
+ "fragment_normative": true,
465
+ "modality": "normative",
466
+ "text": "C_{\"C\"}(t) must not exceed 0.7 times the absolute value of the MPE for the maximum creep test load at any time t over the 30 minute creep test period."
467
+ },
468
+ {
469
+ "address": "clause-2.1.5.2/s1",
470
+ "fragment": "clause-2.1.5.2",
471
+ "clause": "2.1.5.2",
472
+ "kind": "provision",
473
+ "fragment_normative": true,
474
+ "modality": "informative",
475
+ "text": "Calculate the difference between the test indications obtained at t = 20 minutes and t = 30 minutes after the initial indication at t = t_0 and divide by f to obtain the creep error, C_{\"C\"} (30 - 20), in terms of the load cell verification interval, v."
476
+ },
477
+ {
478
+ "address": "clause-2.1.5.2/s2",
479
+ "fragment": "clause-2.1.5.2",
480
+ "clause": "2.1.5.2",
481
+ "kind": "provision",
482
+ "fragment_normative": true,
483
+ "modality": "informative",
484
+ "text": "C_{\"C\"} (30 - 20) = (\"indication at time\" quad t = 30 quad \"minutes\" - \"indication at time\" quad t = 20 quad \"minutes\") // f"
485
+ },
486
+ {
487
+ "address": "clause-2.1.5.3/s1",
488
+ "fragment": "clause-2.1.5.3",
489
+ "clause": "2.1.5.3",
490
+ "kind": "provision",
491
+ "fragment_normative": true,
492
+ "modality": "normative",
493
+ "text": "C_C (30 - 20) shall not exceed 0.15 times the absolute value of the MPE for the applied load."
494
+ },
495
+ {
496
+ "address": "clause-2.1.5.4/s1",
497
+ "fragment": "clause-2.1.5.4",
498
+ "clause": "2.1.5.4",
499
+ "kind": "provision",
500
+ "fragment_normative": true,
501
+ "modality": "informative",
502
+ "text": "Calculate the difference between the initial indication obtained at the minimum creep test load after the stabilisation period (t_0 = 0 \"unitsml(min)\") and the indication at the minimum creep test load after the creep test and after a time interval for stabilisation (t > 30 \"unitsml(min)\") and divide the result by conversion factor, f, to obtain the minimum dead load output return, C_{\"DR\"}, in terms of v."
503
+ },
504
+ {
505
+ "address": "clause-2.1.5.4/s2",
506
+ "fragment": "clause-2.1.5.4",
507
+ "clause": "2.1.5.4",
508
+ "kind": "provision",
509
+ "fragment_normative": true,
510
+ "modality": "informative",
511
+ "text": "C_{\"DR\"} = (\"minimum test load indication\"2 - \"minimum test load indication\"1) // f"
512
+ },
513
+ {
514
+ "address": "clause-2.1.5.5/s1",
515
+ "fragment": "clause-2.1.5.5",
516
+ "clause": "2.1.5.5",
517
+ "kind": "provision",
518
+ "fragment_normative": true,
519
+ "modality": "normative",
520
+ "text": "If the time intervals specified in R 60-2, Table 1 have been met, C_{\"DR\"} must not exceed 0.5 v."
521
+ },
522
+ {
523
+ "address": "clause-2.1.5.6/s1",
524
+ "fragment": "clause-2.1.5.6",
525
+ "clause": "2.1.5.6",
526
+ "kind": "provision",
527
+ "fragment_normative": true,
528
+ "modality": "informative",
529
+ "text": "If the actual time is between 100 % and 150 % of the specified time in R 60-2, Table 1, then the following applies:"
530
+ },
531
+ {
532
+ "address": "clause-2.1.5.6/s2",
533
+ "fragment": "clause-2.1.5.6",
534
+ "clause": "2.1.5.6",
535
+ "kind": "provision",
536
+ "fragment_normative": true,
537
+ "modality": "informative",
538
+ "text": "C_{\"DR\"} <= 0.5 (1 - (x - 1)) v"
539
+ },
540
+ {
541
+ "address": "clause-2.1.5.6/s3",
542
+ "fragment": "clause-2.1.5.6",
543
+ "clause": "2.1.5.6",
544
+ "kind": "provision",
545
+ "fragment_normative": true,
546
+ "modality": "informative",
547
+ "text": "with"
548
+ },
549
+ {
550
+ "address": "clause-2.1.5.6/s4",
551
+ "fragment": "clause-2.1.5.6",
552
+ "clause": "2.1.5.6",
553
+ "kind": "provision",
554
+ "fragment_normative": true,
555
+ "modality": "informative",
556
+ "text": "x = actual time/specified time"
557
+ },
558
+ {
559
+ "address": "clause-2.1.5.7/s1",
560
+ "fragment": "clause-2.1.5.7",
561
+ "clause": "2.1.5.7",
562
+ "kind": "provision",
563
+ "fragment_normative": true,
564
+ "modality": "informative",
565
+ "text": "Whereas C_{\"DR\"} expresses the minimum dead load output return in terms of v, the value of DR as used in OIML R 76 [1] is expressed in units of mass (\"unitsml(g)\", \"unitsml(kg)\" or \"unitsml(t)\")."
566
+ },
567
+ {
568
+ "address": "clause-2.1.5.8/s1",
569
+ "fragment": "clause-2.1.5.8",
570
+ "clause": "2.1.5.8",
571
+ "kind": "provision",
572
+ "fragment_normative": true,
573
+ "modality": "informative",
574
+ "text": "Calculate the minimum dead load output return, DR, expressed in units of mass (\"unitsml(g)\", \"unitsml(kg)\" or \"unitsml(t)\") as follows: DR_ = (E_{\"max\"} - E_{\"min\"}) C_{\"DR\"} // n_{\"LC\"}"
575
+ },
576
+ {
577
+ "address": "clause-2.1.5.9/s1",
578
+ "fragment": "clause-2.1.5.9",
579
+ "clause": "2.1.5.9",
580
+ "kind": "provision",
581
+ "fragment_normative": true,
582
+ "modality": "normative",
583
+ "text": "Regardless of the value declared by the manufacturer for the apportionment factor, p_{\"LC\"}, the MPE for creep shall be determined from R 60-1, Table 4 using the apportionment factor, p_{\"LC\"} = 0.7 (see R 60-1, 5.5.1)."
584
+ },
585
+ {
586
+ "address": "clause-2.1.6.1/s1",
587
+ "fragment": "clause-2.1.6.1",
588
+ "clause": "2.1.6.1",
589
+ "kind": "provision",
590
+ "fragment_normative": true,
591
+ "modality": "informative",
592
+ "text": "From the test indications recorded in R 60-3, table-6.9, calculate the difference between the indications for each pressure and divide the result by conversion factor, f, to obtain the change, C_{\"P\"}, in terms of v."
593
+ },
594
+ {
595
+ "address": "clause-2.1.6.1/s2",
596
+ "fragment": "clause-2.1.6.1",
597
+ "clause": "2.1.6.1",
598
+ "kind": "provision",
599
+ "fragment_normative": true,
600
+ "modality": "informative",
601
+ "text": "C_P = (\"indication at \" P_2 - \"indication at \" P_1) // f"
602
+ },
603
+ {
604
+ "address": "clause-2.1.6.2/s1",
605
+ "fragment": "clause-2.1.6.2",
606
+ "clause": "2.1.6.2",
607
+ "kind": "provision",
608
+ "fragment_normative": true,
609
+ "modality": "informative",
610
+ "text": "Divide C_{\"P\"} by (P_2 - P_1) to determine the change due to barometric pressure in terms of v per kilopascal (\"unitsml(kPa)\")."
611
+ },
612
+ {
613
+ "address": "clause-2.1.6.3/s1",
614
+ "fragment": "clause-2.1.6.3",
615
+ "clause": "2.1.6.3",
616
+ "kind": "provision",
617
+ "fragment_normative": true,
618
+ "modality": "informative",
619
+ "text": "Multiply the result by [(E_{\"max\"} - E_{\"min\"}) // n_{\"LC\"} to obtain the result in units of mass (g, kg, or t) per \"unitsml(kPa)\" (as stated by the manufacturer)."
620
+ },
621
+ {
622
+ "address": "clause-2.1.6.3/s2",
623
+ "fragment": "clause-2.1.6.3",
624
+ "clause": "2.1.6.3",
625
+ "kind": "provision",
626
+ "fragment_normative": true,
627
+ "modality": "normative",
628
+ "text": "The result must not exceed v_{\"min\"}."
629
+ },
630
+ {
631
+ "address": "clause-2.1.6.3/s3",
632
+ "fragment": "clause-2.1.6.3",
633
+ "clause": "2.1.6.3",
634
+ "kind": "provision",
635
+ "fragment_normative": true,
636
+ "modality": "informative",
637
+ "text": "C_P(v) = C_P/{(P_2 - P_1)} cdot {(E_{\"max\"} - E_{\"min\"})}/n_{\"max\"} <= v_min"
638
+ },
639
+ {
640
+ "address": "clause-2.1.7/s1",
641
+ "fragment": "clause-2.1.7",
642
+ "clause": "2.1.7",
643
+ "kind": "provision",
644
+ "fragment_normative": true,
645
+ "modality": "informative",
646
+ "text": "(C_{\"Hmin\"} = Change in terms of v due to Humidity effect on the indication of the minimum test load D_{\"min\"})"
647
+ },
648
+ {
649
+ "address": "clause-2.1.7/s2",
650
+ "fragment": "clause-2.1.7",
651
+ "clause": "2.1.7",
652
+ "kind": "provision",
653
+ "fragment_normative": true,
654
+ "modality": "informative",
655
+ "text": "(C_{\"Hmax\"} = Change due to Humidity effect on the indication of the maximum test load D_{\"max\"})"
656
+ },
657
+ {
658
+ "address": "clause-2.1.7/s3",
659
+ "fragment": "clause-2.1.7",
660
+ "clause": "2.1.7",
661
+ "kind": "provision",
662
+ "fragment_normative": true,
663
+ "modality": "normative",
664
+ "text": "Remark: If the minimum or maximum test load used for this test differ from the minimum test load D_{\"min\"} or maximum test load D_{\"max\"} according to R 60-3, 2.1.2 “Load cell errors E_{\"L\"}” the conversion factor, f, must be recalculated with the minimum and maximum test loads of this test (see R 60-3, 2.1.2.4)."
665
+ },
666
+ {
667
+ "address": "clause-2.1.7.1/s1",
668
+ "fragment": "clause-2.1.7.1",
669
+ "clause": "2.1.7.1",
670
+ "kind": "provision",
671
+ "fragment_normative": true,
672
+ "modality": "informative",
673
+ "text": "From the test indications recorded in R 60-3, Table 6.10.1, calculate the difference between the initial indications for the minimum test load, D_{\"min\"}, before and after the damp heat test and divide the result by conversion factor, f, to obtain the change, C_{\"Hmin\"}, in terms of verification interval, v (see R 60-1, 5.6.3.1)."
674
+ },
675
+ {
676
+ "address": "clause-2.1.7.1/s2",
677
+ "fragment": "clause-2.1.7.1",
678
+ "clause": "2.1.7.1",
679
+ "kind": "provision",
680
+ "fragment_normative": true,
681
+ "modality": "informative",
682
+ "text": "C_{\"Hmin\"} = [(\"indication at \" D_{\"min\"})_{\"after\"} - (\"indication at \" D_{\"min\"} )_{\"before\"}] // f"
683
+ },
684
+ {
685
+ "address": "clause-2.1.7.1/s3",
686
+ "fragment": "clause-2.1.7.1",
687
+ "clause": "2.1.7.1",
688
+ "kind": "provision",
689
+ "fragment_normative": true,
690
+ "modality": "normative",
691
+ "text": "C_{\"Hmin\"} \" must not exceed 0.04 \" cdot n."
692
+ },
693
+ {
694
+ "address": "clause-2.1.7.2/s1",
695
+ "fragment": "clause-2.1.7.2",
696
+ "clause": "2.1.7.2",
697
+ "kind": "provision",
698
+ "fragment_normative": true,
699
+ "modality": "informative",
700
+ "text": "Calculate the average indications bar I{D_{\"max\"}} and bar I{D_{\"min\"} at D_{\"min\"} (see R 60-2, 2.10.5) for the required number of test indications, before and after the damp heat test."
701
+ },
702
+ {
703
+ "address": "clause-2.1.7.2/s2",
704
+ "fragment": "clause-2.1.7.2",
705
+ "clause": "2.1.7.2",
706
+ "kind": "provision",
707
+ "fragment_normative": true,
708
+ "modality": "informative",
709
+ "text": "Subtract bar I{D_{\"min\" from bar I{D_{\"max\"}} for the tests before and after damp heat test and then calculate the difference between the results."
710
+ },
711
+ {
712
+ "address": "clause-2.1.7.2/s3",
713
+ "fragment": "clause-2.1.7.2",
714
+ "clause": "2.1.7.2",
715
+ "kind": "provision",
716
+ "fragment_normative": true,
717
+ "modality": "informative",
718
+ "text": "Divide the result by the conversion factor, f, to obtain the change, C_{\"Hmax\"} in terms of v."
719
+ },
720
+ {
721
+ "address": "clause-2.1.7.2/s4",
722
+ "fragment": "clause-2.1.7.2",
723
+ "clause": "2.1.7.2",
724
+ "kind": "provision",
725
+ "fragment_normative": true,
726
+ "modality": "informative",
727
+ "text": "C_{\"Hmax\"} = {[(bar I{D_{\"max\"}} - bar I{D_{\"min\"}})_{\"after\"} - (bar I{D_{\"max\"}} - bar I{D_{\"min\"}})_{\"before\"}]} / f"
728
+ },
729
+ {
730
+ "address": "clause-2.1.7.3/s1",
731
+ "fragment": "clause-2.1.7.3",
732
+ "clause": "2.1.7.3",
733
+ "kind": "provision",
734
+ "fragment_normative": true,
735
+ "modality": "normative",
736
+ "text": "C_{\"Hmax\"} must not exceed the MPE (see R 60-1, Table 4 in 5.3.2)."
737
+ },
738
+ {
739
+ "address": "clause-2.1.8/s1",
740
+ "fragment": "clause-2.1.8",
741
+ "clause": "2.1.8",
742
+ "kind": "provision",
743
+ "fragment_normative": true,
744
+ "modality": "informative",
745
+ "text": "Report load test errors at different temperatures and humidity conditions using R 60-3, Forms 6.3, then indicate the results in R 60-3, Table 6.10.2 utilising the procedure contained within “load cell errors” procedure, R 60-3, 2.1.2, in a manner similar to that used for the preparation of R 60-3, Table 6.5."
746
+ },
747
+ {
748
+ "address": "clause-2.2.1.1/s1",
749
+ "fragment": "clause-2.2.1.1",
750
+ "clause": "2.2.1.1",
751
+ "kind": "provision",
752
+ "fragment_normative": true,
753
+ "modality": "informative",
754
+ "text": "Enter data on R 60-3, Form 6.11 (Warm-up time)."
755
+ },
756
+ {
757
+ "address": "clause-2.2.1.2/s1",
758
+ "fragment": "clause-2.2.1.2",
759
+ "clause": "2.2.1.2",
760
+ "kind": "provision",
761
+ "fragment_normative": true,
762
+ "modality": "informative",
763
+ "text": "Span is the result of subtraction of the indication at the minimum test load, D_{\"min\"}, from the indication at the maximum test load, D_{\"max\"}."
764
+ },
765
+ {
766
+ "address": "clause-2.2.1.3/s1",
767
+ "fragment": "clause-2.2.1.3",
768
+ "clause": "2.2.1.3",
769
+ "kind": "provision",
770
+ "fragment_normative": true,
771
+ "modality": "informative",
772
+ "text": "Change is the difference between the span and the initial run span."
773
+ },
774
+ {
775
+ "address": "clause-2.2.2.1/s1",
776
+ "fragment": "clause-2.2.2.1",
777
+ "clause": "2.2.2.1",
778
+ "kind": "provision",
779
+ "fragment_normative": true,
780
+ "modality": "informative",
781
+ "text": "Enter data on R 60-3, Form 6.12."
782
+ },
783
+ {
784
+ "address": "clause-2.2.2.2/s1",
785
+ "fragment": "clause-2.2.2.2",
786
+ "clause": "2.2.2.2",
787
+ "kind": "provision",
788
+ "fragment_normative": true,
789
+ "modality": "informative",
790
+ "text": "Perform load tests and record results utilising R 60-3, Form 6.12."
791
+ },
792
+ {
793
+ "address": "clause-2.2.2.3/s1",
794
+ "fragment": "clause-2.2.2.3",
795
+ "clause": "2.2.2.3",
796
+ "kind": "provision",
797
+ "fragment_normative": true,
798
+ "modality": "informative",
799
+ "text": "Calculate reference indications in accordance with the “load cell errors” procedure, R 60-3, 2.1.2."
800
+ },
801
+ {
802
+ "address": "clause-2.2.2.4/s1",
803
+ "fragment": "clause-2.2.2.4",
804
+ "clause": "2.2.2.4",
805
+ "kind": "provision",
806
+ "fragment_normative": true,
807
+ "modality": "informative",
808
+ "text": "Indicate results on R 60-3, Form 6.12."
809
+ },
810
+ {
811
+ "address": "clause-2.2.3.1/s1",
812
+ "fragment": "clause-2.2.3.1",
813
+ "clause": "2.2.3.1",
814
+ "kind": "provision",
815
+ "fragment_normative": true,
816
+ "modality": "informative",
817
+ "text": "Enter data on R 60-3, Form 6.13."
818
+ },
819
+ {
820
+ "address": "clause-2.2.3.2/s1",
821
+ "fragment": "clause-2.2.3.2",
822
+ "clause": "2.2.3.2",
823
+ "kind": "provision",
824
+ "fragment_normative": true,
825
+ "modality": "informative",
826
+ "text": "Calculate the difference, which is:"
827
+ },
828
+ {
829
+ "address": "clause-2.2.3.2/s2",
830
+ "fragment": "clause-2.2.3.2",
831
+ "clause": "2.2.3.2",
832
+ "kind": "provision",
833
+ "fragment_normative": true,
834
+ "modality": "informative",
835
+ "text": "\"difference\" = {(\"indication with disturbance, in units\" - \"indication without disturbance, in units\")} / {\"conversion factor\", f}"
836
+ },
837
+ {
838
+ "address": "clause-2.2.3.3/s1",
839
+ "fragment": "clause-2.2.3.3",
840
+ "clause": "2.2.3.3",
841
+ "kind": "provision",
842
+ "fragment_normative": true,
843
+ "modality": "informative",
844
+ "text": "Indicate results on R 60-3, Form 6.13."
845
+ },
846
+ {
847
+ "address": "clause-2.2.4.1/s1",
848
+ "fragment": "clause-2.2.4.1",
849
+ "clause": "2.2.4.1",
850
+ "kind": "provision",
851
+ "fragment_normative": true,
852
+ "modality": "informative",
853
+ "text": "Enter data on R 60-3, Forms 6.14.1 and 6.14.2."
854
+ },
855
+ {
856
+ "address": "clause-2.2.4.2/s1",
857
+ "fragment": "clause-2.2.4.2",
858
+ "clause": "2.2.4.2",
859
+ "kind": "provision",
860
+ "fragment_normative": true,
861
+ "modality": "informative",
862
+ "text": "Indicate results on R 60-3, Forms 6.14.1 and 6.14.2."
863
+ },
864
+ {
865
+ "address": "clause-2.2.5.1/s1",
866
+ "fragment": "clause-2.2.5.1",
867
+ "clause": "2.2.5.1",
868
+ "kind": "provision",
869
+ "fragment_normative": true,
870
+ "modality": "informative",
871
+ "text": "Enter data on R 60-3, Forms 6.15"
872
+ },
873
+ {
874
+ "address": "clause-2.2.5.1/s2",
875
+ "fragment": "clause-2.2.5.1",
876
+ "clause": "2.2.5.1",
877
+ "kind": "provision",
878
+ "fragment_normative": true,
879
+ "modality": "informative",
880
+ "text": "\"difference\" = {(\"indication with disturbance, in units\" - \"indication without disturbance, in units\")} / {\"conversion factor, \" f}"
881
+ },
882
+ {
883
+ "address": "clause-2.2.5.2/s1",
884
+ "fragment": "clause-2.2.5.2",
885
+ "clause": "2.2.5.2",
886
+ "kind": "provision",
887
+ "fragment_normative": true,
888
+ "modality": "informative",
889
+ "text": "Indicate results on R 60-3, Forms 6.15"
890
+ },
891
+ {
892
+ "address": "clause-2.2.6.1/s1",
893
+ "fragment": "clause-2.2.6.1",
894
+ "clause": "2.2.6.1",
895
+ "kind": "provision",
896
+ "fragment_normative": true,
897
+ "modality": "informative",
898
+ "text": "Enter data on R 60-3, Forms 6.16.1, 6.16.2 and 6.16.3."
899
+ },
900
+ {
901
+ "address": "clause-2.2.6.2/s1",
902
+ "fragment": "clause-2.2.6.2",
903
+ "clause": "2.2.6.2",
904
+ "kind": "provision",
905
+ "fragment_normative": true,
906
+ "modality": "informative",
907
+ "text": "Calculate the difference, which is:"
908
+ },
909
+ {
910
+ "address": "clause-2.2.6.2/s2",
911
+ "fragment": "clause-2.2.6.2",
912
+ "clause": "2.2.6.2",
913
+ "kind": "provision",
914
+ "fragment_normative": true,
915
+ "modality": "informative",
916
+ "text": "\"difference\" = {(\"indication with disturbance, in units\" - \"indication without disturbance, in units\")} / {\"conversion factor\", f}"
917
+ },
918
+ {
919
+ "address": "clause-2.2.6.3/s1",
920
+ "fragment": "clause-2.2.6.3",
921
+ "clause": "2.2.6.3",
922
+ "kind": "provision",
923
+ "fragment_normative": true,
924
+ "modality": "informative",
925
+ "text": "Indicate results on R 60-3, Forms 6.16.1, 6.16.2.1, and 6.16.2.2."
926
+ },
927
+ {
928
+ "address": "clause-2.2.6.4/s1",
929
+ "fragment": "clause-2.2.6.4",
930
+ "clause": "2.2.6.4",
931
+ "kind": "provision",
932
+ "fragment_normative": true,
933
+ "modality": "informative",
934
+ "text": "Provide test point information on Form 6.16.3."
935
+ },
936
+ {
937
+ "address": "clause-2.2.7.1/s1",
938
+ "fragment": "clause-2.2.7.1",
939
+ "clause": "2.2.7.1",
940
+ "kind": "provision",
941
+ "fragment_normative": true,
942
+ "modality": "informative",
943
+ "text": "Enter data on R 60-3, Form 6.17.1."
944
+ },
945
+ {
946
+ "address": "clause-2.2.7.2/s1",
947
+ "fragment": "clause-2.2.7.2",
948
+ "clause": "2.2.7.2",
949
+ "kind": "provision",
950
+ "fragment_normative": true,
951
+ "modality": "informative",
952
+ "text": "Calculate the difference, which is:"
953
+ },
954
+ {
955
+ "address": "clause-2.2.7.2/s2",
956
+ "fragment": "clause-2.2.7.2",
957
+ "clause": "2.2.7.2",
958
+ "kind": "provision",
959
+ "fragment_normative": true,
960
+ "modality": "informative",
961
+ "text": "\"difference\" = {(\"indication with disturbance, in units\" - \"indication without disturbance, in units\")} / {\"conversion factor\", f}"
962
+ },
963
+ {
964
+ "address": "clause-2.2.7.3/s1",
965
+ "fragment": "clause-2.2.7.3",
966
+ "clause": "2.2.7.3",
967
+ "kind": "provision",
968
+ "fragment_normative": true,
969
+ "modality": "informative",
970
+ "text": "Indicate results on R 60-3, Form 6.17.1."
971
+ },
972
+ {
973
+ "address": "clause-2.2.7.4/s1",
974
+ "fragment": "clause-2.2.7.4",
975
+ "clause": "2.2.7.4",
976
+ "kind": "provision",
977
+ "fragment_normative": true,
978
+ "modality": "informative",
979
+ "text": "Provide test set-up information on R 60-3, Form 6.17.2."
980
+ },
981
+ {
982
+ "address": "clause-2.2.8.1/s1",
983
+ "fragment": "clause-2.2.8.1",
984
+ "clause": "2.2.8.1",
985
+ "kind": "provision",
986
+ "fragment_normative": true,
987
+ "modality": "informative",
988
+ "text": "Enter data on R 60-3, Form 6.18."
989
+ },
990
+ {
991
+ "address": "clause-2.2.8.2/s1",
992
+ "fragment": "clause-2.2.8.2",
993
+ "clause": "2.2.8.2",
994
+ "kind": "provision",
995
+ "fragment_normative": true,
996
+ "modality": "informative",
997
+ "text": "Calculate the difference, which is:"
998
+ },
999
+ {
1000
+ "address": "clause-2.2.8.2/s2",
1001
+ "fragment": "clause-2.2.8.2",
1002
+ "clause": "2.2.8.2",
1003
+ "kind": "provision",
1004
+ "fragment_normative": true,
1005
+ "modality": "informative",
1006
+ "text": "\"difference\" = {(\"indication with disturbance, in units\" - \"indication without disturbance, in units\")} / {\"conversion factor\", f}"
1007
+ },
1008
+ {
1009
+ "address": "clause-2.2.8.3/s1",
1010
+ "fragment": "clause-2.2.8.3",
1011
+ "clause": "2.2.8.3",
1012
+ "kind": "provision",
1013
+ "fragment_normative": true,
1014
+ "modality": "informative",
1015
+ "text": "Indicate results on R 60-3, Form 6.18."
1016
+ },
1017
+ {
1018
+ "address": "clause-2.2.8.4/s1",
1019
+ "fragment": "clause-2.2.8.4",
1020
+ "clause": "2.2.8.4",
1021
+ "kind": "provision",
1022
+ "fragment_normative": true,
1023
+ "modality": "informative",
1024
+ "text": "Provide test setup information on R 60-3, Form 6.18."
1025
+ },
1026
+ {
1027
+ "address": "clause-2.2.9.1/s1",
1028
+ "fragment": "clause-2.2.9.1",
1029
+ "clause": "2.2.9.1",
1030
+ "kind": "provision",
1031
+ "fragment_normative": true,
1032
+ "modality": "informative",
1033
+ "text": "Enter data on R 60-3, Forms 6.19.1 (3 runs) to 6.19.2 (5 runs)."
1034
+ },
1035
+ {
1036
+ "address": "clause-2.2.9.2/s1",
1037
+ "fragment": "clause-2.2.9.2",
1038
+ "clause": "2.2.9.2",
1039
+ "kind": "provision",
1040
+ "fragment_normative": true,
1041
+ "modality": "informative",
1042
+ "text": "Calculate averages and record on R 60-3, Forms 6.19.1 (3 runs) to 6.19.2 (5 runs)."
1043
+ },
1044
+ {
1045
+ "address": "clause-2.2.9.3/s1",
1046
+ "fragment": "clause-2.2.9.3",
1047
+ "clause": "2.2.9.3",
1048
+ "kind": "provision",
1049
+ "fragment_normative": true,
1050
+ "modality": "informative",
1051
+ "text": "Indicate results on R 60-3, Form 6.19.3"
1052
+ },
1053
+ {
1054
+ "address": "clause-2.3.1/s1",
1055
+ "fragment": "clause-2.3.1",
1056
+ "clause": "2.3.1",
1057
+ "kind": "provision",
1058
+ "fragment_normative": true,
1059
+ "modality": "normative",
1060
+ "text": "Absolute (not relative) time shall be recorded."
1061
+ },
1062
+ {
1063
+ "address": "clause-2.3.1/note-1/s1",
1064
+ "fragment": "clause-2.3.1/note-1",
1065
+ "kind": "note",
1066
+ "fragment_normative": false,
1067
+ "modality": "informative",
1068
+ "text": "For example, Figure 1 below gives a sample plot depicting the combined errors versus applied load."
1069
+ },
1070
+ {
1071
+ "address": "clause-2.3.2/s1",
1072
+ "fragment": "clause-2.3.2",
1073
+ "clause": "2.3.2",
1074
+ "kind": "provision",
1075
+ "fragment_normative": true,
1076
+ "modality": "normative",
1077
+ "text": "When reporting values for individual test data, the data should be truncated to two significant digits to the right of the decimal place and reported in load cell verification intervals, v."
1078
+ },
1079
+ {
1080
+ "address": "clause-2.5/table-1/note-1/s1",
1081
+ "fragment": "clause-2.5/table-1/note-1",
1082
+ "kind": "note",
1083
+ "fragment_normative": false,
1084
+ "modality": "informative",
1085
+ "text": "Observe extreme caution by referring to calculation procedure for correct application of these formulae."
1086
+ },
1087
+ {
1088
+ "address": "clause-2.5/table-1/note-2/s1",
1089
+ "fragment": "clause-2.5/table-1/note-2",
1090
+ "kind": "note",
1091
+ "fragment_normative": false,
1092
+ "modality": "informative",
1093
+ "text": "Use with initial 20 \"unitsml(degC)\" ascending load run only."
1094
+ },
1095
+ {
1096
+ "address": "clause-2.5/table-1/note-2/s2",
1097
+ "fragment": "clause-2.5/table-1/note-2",
1098
+ "kind": "note",
1099
+ "fragment_normative": false,
1100
+ "modality": "informative",
1101
+ "text": "Refer to R 60-2, 2.8.2."
1102
+ },
1103
+ {
1104
+ "address": "clause-3/s1",
1105
+ "fragment": "clause-3",
1106
+ "clause": "3",
1107
+ "kind": "provision",
1108
+ "fragment_normative": true,
1109
+ "modality": "normative",
1110
+ "text": "In case a prescribed test is not relevant for the type of instrument to be tested, the reason why the test is omitted shall be clearly stated in the field “Remarks” (for instance surge tests on signal lines shorter than 30 m, tests related to AC mains supply in case of an instrument only powered by batteries, or partial testing after modification of a previously tested type)."
1111
+ },
1112
+ {
1113
+ "address": "clause-3/s2",
1114
+ "fragment": "clause-3",
1115
+ "clause": "3",
1116
+ "kind": "provision",
1117
+ "fragment_normative": true,
1118
+ "modality": "normative",
1119
+ "text": "The number of the report and the page numbers shall be completed in the heading."
1120
+ },
1121
+ {
1122
+ "address": "clause-3/s3",
1123
+ "fragment": "clause-3",
1124
+ "clause": "3",
1125
+ "kind": "provision",
1126
+ "fragment_normative": true,
1127
+ "modality": "normative",
1128
+ "text": "Page 1 of this Report Format may be replaced by a cover page by the Issuing Authority."
1129
+ },
1130
+ {
1131
+ "address": "clause-3/s4",
1132
+ "fragment": "clause-3",
1133
+ "clause": "3",
1134
+ "kind": "provision",
1135
+ "fragment_normative": true,
1136
+ "modality": "informative",
1137
+ "text": "Enter “NA” or “/” for “the test is not applicable”."
1138
+ },
1139
+ {
1140
+ "address": "clause-4/s1",
1141
+ "fragment": "clause-4",
1142
+ "clause": "4",
1143
+ "kind": "provision",
1144
+ "fragment_normative": true,
1145
+ "modality": "informative",
1146
+ "text": "Cover page by the Issuing Authority"
1147
+ },
1148
+ {
1149
+ "address": "clause-4.3/s1",
1150
+ "fragment": "clause-4.3",
1151
+ "clause": "4.3",
1152
+ "kind": "provision",
1153
+ "fragment_normative": true,
1154
+ "modality": "informative",
1155
+ "text": "To be completed by the Issuing Authority"
1156
+ },
1157
+ {
1158
+ "address": "clause-4.3.1/s1",
1159
+ "fragment": "clause-4.3.1",
1160
+ "clause": "4.3.1",
1161
+ "kind": "provision",
1162
+ "fragment_normative": true,
1163
+ "modality": "informative",
1164
+ "text": "For details, refer to the tests as indicated in the last column."
1165
+ },
1166
+ {
1167
+ "address": "clause-4.3.2/s1",
1168
+ "fragment": "clause-4.3.2",
1169
+ "clause": "4.3.2",
1170
+ "kind": "provision",
1171
+ "fragment_normative": true,
1172
+ "modality": "informative",
1173
+ "text": "For details, refer to the tests as indicated in the last column."
1174
+ },
1175
+ {
1176
+ "address": "clause-4.3.2/s2",
1177
+ "fragment": "clause-4.3.2",
1178
+ "clause": "4.3.2",
1179
+ "kind": "provision",
1180
+ "fragment_normative": true,
1181
+ "modality": "informative",
1182
+ "text": "Tests performed at (20 \"unitsml(degC)\" / X_1 \"unitsml(degC)\" / X_2 \"unitsml(degC)\" / 20 \"unitsml(degC)\"):"
1183
+ },
1184
+ {
1185
+ "address": "clause-4.3.2/s3",
1186
+ "fragment": "clause-4.3.2",
1187
+ "clause": "4.3.2",
1188
+ "kind": "provision",
1189
+ "fragment_normative": true,
1190
+ "modality": "informative",
1191
+ "text": "Additional tests performed for digital load cells:"
1192
+ },
1193
+ {
1194
+ "address": "clause-4.4.3/s1",
1195
+ "fragment": "clause-4.4.3",
1196
+ "clause": "4.4.3",
1197
+ "kind": "provision",
1198
+ "fragment_normative": true,
1199
+ "modality": "informative",
1200
+ "text": "(This table has to be completed for each test laboratory)"
1201
+ },
1202
+ {
1203
+ "address": "clause-4.5/s1",
1204
+ "fragment": "clause-4.5",
1205
+ "clause": "4.5",
1206
+ "kind": "provision",
1207
+ "fragment_normative": true,
1208
+ "modality": "informative",
1209
+ "text": "(as provided by the manufacturer prior to the evaluation)"
1210
+ },
1211
+ {
1212
+ "address": "clause-4.6/s1",
1213
+ "fragment": "clause-4.6",
1214
+ "clause": "4.6",
1215
+ "kind": "provision",
1216
+ "fragment_normative": true,
1217
+ "modality": "informative",
1218
+ "text": "Further remarks concerning accessories:"
1219
+ },
1220
+ {
1221
+ "address": "clause-4.6/s2",
1222
+ "fragment": "clause-4.6",
1223
+ "clause": "4.6",
1224
+ "kind": "provision",
1225
+ "fragment_normative": true,
1226
+ "modality": "informative",
1227
+ "text": "_________________________________________________________________________________"
1228
+ },
1229
+ {
1230
+ "address": "clause-4.6/s3",
1231
+ "fragment": "clause-4.6",
1232
+ "clause": "4.6",
1233
+ "kind": "provision",
1234
+ "fragment_normative": true,
1235
+ "modality": "informative",
1236
+ "text": "_________________________________________________________________________________"
1237
+ },
1238
+ {
1239
+ "address": "clause-4.6/s4",
1240
+ "fragment": "clause-4.6",
1241
+ "clause": "4.6",
1242
+ "kind": "provision",
1243
+ "fragment_normative": true,
1244
+ "modality": "informative",
1245
+ "text": "_________________________________________________________________________________"
1246
+ },
1247
+ {
1248
+ "address": "clause-4.6/s5",
1249
+ "fragment": "clause-4.6",
1250
+ "clause": "4.6",
1251
+ "kind": "provision",
1252
+ "fragment_normative": true,
1253
+ "modality": "informative",
1254
+ "text": "_________________________________________________________________________________"
1255
+ },
1256
+ {
1257
+ "address": "clause-4.6/s6",
1258
+ "fragment": "clause-4.6",
1259
+ "clause": "4.6",
1260
+ "kind": "provision",
1261
+ "fragment_normative": true,
1262
+ "modality": "informative",
1263
+ "text": "_________________________________________________________________________________"
1264
+ },
1265
+ {
1266
+ "address": "clause-4.6/s7",
1267
+ "fragment": "clause-4.6",
1268
+ "clause": "4.6",
1269
+ "kind": "provision",
1270
+ "fragment_normative": true,
1271
+ "modality": "informative",
1272
+ "text": "_________________________________________________________________________________"
1273
+ },
1274
+ {
1275
+ "address": "clause-4.7.1/s1",
1276
+ "fragment": "clause-4.7.1",
1277
+ "clause": "4.7.1",
1278
+ "kind": "provision",
1279
+ "fragment_normative": true,
1280
+ "modality": "informative",
1281
+ "text": "This test report is issued for the following load cell:"
1282
+ },
1283
+ {
1284
+ "address": "clause-4.7.2/s1",
1285
+ "fragment": "clause-4.7.2",
1286
+ "clause": "4.7.2",
1287
+ "kind": "provision",
1288
+ "fragment_normative": true,
1289
+ "modality": "informative",
1290
+ "text": "(refer to R 60-2, 2.3, 2.4 and Annex D):"
1291
+ },
1292
+ {
1293
+ "address": "clause-4.8/s1",
1294
+ "fragment": "clause-4.8",
1295
+ "clause": "4.8",
1296
+ "kind": "provision",
1297
+ "fragment_normative": true,
1298
+ "modality": "informative",
1299
+ "text": "Justification of the selection of the test sample(s) (refer to R 60-2, 2.3):"
1300
+ },
1301
+ {
1302
+ "address": "clause-4.8/s2",
1303
+ "fragment": "clause-4.8",
1304
+ "clause": "4.8",
1305
+ "kind": "provision",
1306
+ "fragment_normative": true,
1307
+ "modality": "informative",
1308
+ "text": "Further information concerning adjustments:"
1309
+ },
1310
+ {
1311
+ "address": "clause-4.8/s3",
1312
+ "fragment": "clause-4.8",
1313
+ "clause": "4.8",
1314
+ "kind": "provision",
1315
+ "fragment_normative": true,
1316
+ "modality": "informative",
1317
+ "text": "_________________________________________________________________________________"
1318
+ },
1319
+ {
1320
+ "address": "clause-4.8/s4",
1321
+ "fragment": "clause-4.8",
1322
+ "clause": "4.8",
1323
+ "kind": "provision",
1324
+ "fragment_normative": true,
1325
+ "modality": "informative",
1326
+ "text": "_________________________________________________________________________________"
1327
+ },
1328
+ {
1329
+ "address": "clause-4.8/s5",
1330
+ "fragment": "clause-4.8",
1331
+ "clause": "4.8",
1332
+ "kind": "provision",
1333
+ "fragment_normative": true,
1334
+ "modality": "informative",
1335
+ "text": "_________________________________________________________________________________"
1336
+ },
1337
+ {
1338
+ "address": "clause-4.8/s6",
1339
+ "fragment": "clause-4.8",
1340
+ "clause": "4.8",
1341
+ "kind": "provision",
1342
+ "fragment_normative": true,
1343
+ "modality": "informative",
1344
+ "text": "_________________________________________________________________________________"
1345
+ },
1346
+ {
1347
+ "address": "clause-4.8/s7",
1348
+ "fragment": "clause-4.8",
1349
+ "clause": "4.8",
1350
+ "kind": "provision",
1351
+ "fragment_normative": true,
1352
+ "modality": "informative",
1353
+ "text": "_________________________________________________________________________________"
1354
+ },
1355
+ {
1356
+ "address": "clause-4.8/s8",
1357
+ "fragment": "clause-4.8",
1358
+ "clause": "4.8",
1359
+ "kind": "provision",
1360
+ "fragment_normative": true,
1361
+ "modality": "informative",
1362
+ "text": "_________________________________________________________________________________"
1363
+ },
1364
+ {
1365
+ "address": "clause-4.9.1/s1",
1366
+ "fragment": "clause-4.9.1",
1367
+ "clause": "4.9.1",
1368
+ "kind": "provision",
1369
+ "fragment_normative": true,
1370
+ "modality": "informative",
1371
+ "text": "Additional information concerning the type (connection equipment, interfaces, etc.):"
1372
+ },
1373
+ {
1374
+ "address": "clause-4.9.1/s2",
1375
+ "fragment": "clause-4.9.1",
1376
+ "clause": "4.9.1",
1377
+ "kind": "provision",
1378
+ "fragment_normative": true,
1379
+ "modality": "informative",
1380
+ "text": "_________________________________________________________________________________"
1381
+ },
1382
+ {
1383
+ "address": "clause-4.9.1/s3",
1384
+ "fragment": "clause-4.9.1",
1385
+ "clause": "4.9.1",
1386
+ "kind": "provision",
1387
+ "fragment_normative": true,
1388
+ "modality": "informative",
1389
+ "text": "_________________________________________________________________________________"
1390
+ },
1391
+ {
1392
+ "address": "clause-4.9.1/s4",
1393
+ "fragment": "clause-4.9.1",
1394
+ "clause": "4.9.1",
1395
+ "kind": "provision",
1396
+ "fragment_normative": true,
1397
+ "modality": "informative",
1398
+ "text": "_________________________________________________________________________________"
1399
+ },
1400
+ {
1401
+ "address": "clause-4.9.1/s5",
1402
+ "fragment": "clause-4.9.1",
1403
+ "clause": "4.9.1",
1404
+ "kind": "provision",
1405
+ "fragment_normative": true,
1406
+ "modality": "informative",
1407
+ "text": "_________________________________________________________________________________"
1408
+ },
1409
+ {
1410
+ "address": "clause-4.9.1/s6",
1411
+ "fragment": "clause-4.9.1",
1412
+ "clause": "4.9.1",
1413
+ "kind": "provision",
1414
+ "fragment_normative": true,
1415
+ "modality": "informative",
1416
+ "text": "_________________________________________________________________________________"
1417
+ },
1418
+ {
1419
+ "address": "clause-4.9.1/s7",
1420
+ "fragment": "clause-4.9.1",
1421
+ "clause": "4.9.1",
1422
+ "kind": "provision",
1423
+ "fragment_normative": true,
1424
+ "modality": "informative",
1425
+ "text": "_________________________________________________________________________________"
1426
+ },
1427
+ {
1428
+ "address": "clause-4.9.2/s1",
1429
+ "fragment": "clause-4.9.2",
1430
+ "clause": "4.9.2",
1431
+ "kind": "provision",
1432
+ "fragment_normative": true,
1433
+ "modality": "informative",
1434
+ "text": "(Refer to R 60-1, 6.2.2, 6.2.3, and 6.2.4)"
1435
+ },
1436
+ {
1437
+ "address": "clause-4.9.6/s1",
1438
+ "fragment": "clause-4.9.6",
1439
+ "clause": "4.9.6",
1440
+ "kind": "provision",
1441
+ "fragment_normative": true,
1442
+ "modality": "informative",
1443
+ "text": "(according to manufacturer statement, refer to R 60-1, 6.2)"
1444
+ },
1445
+ {
1446
+ "address": "clause-4.9.6/s2",
1447
+ "fragment": "clause-4.9.6",
1448
+ "clause": "4.9.6",
1449
+ "kind": "provision",
1450
+ "fragment_normative": true,
1451
+ "modality": "informative",
1452
+ "text": "Further load cell information given by the manufacturer:"
1453
+ },
1454
+ {
1455
+ "address": "clause-4.9.6/s3",
1456
+ "fragment": "clause-4.9.6",
1457
+ "clause": "4.9.6",
1458
+ "kind": "provision",
1459
+ "fragment_normative": true,
1460
+ "modality": "informative",
1461
+ "text": "_________________________________________________________________________________"
1462
+ },
1463
+ {
1464
+ "address": "clause-4.9.6/s4",
1465
+ "fragment": "clause-4.9.6",
1466
+ "clause": "4.9.6",
1467
+ "kind": "provision",
1468
+ "fragment_normative": true,
1469
+ "modality": "informative",
1470
+ "text": "_________________________________________________________________________________"
1471
+ },
1472
+ {
1473
+ "address": "clause-4.9.6/s5",
1474
+ "fragment": "clause-4.9.6",
1475
+ "clause": "4.9.6",
1476
+ "kind": "provision",
1477
+ "fragment_normative": true,
1478
+ "modality": "informative",
1479
+ "text": "_________________________________________________________________________________"
1480
+ },
1481
+ {
1482
+ "address": "clause-4.9.6/s6",
1483
+ "fragment": "clause-4.9.6",
1484
+ "clause": "4.9.6",
1485
+ "kind": "provision",
1486
+ "fragment_normative": true,
1487
+ "modality": "informative",
1488
+ "text": "_________________________________________________________________________________"
1489
+ },
1490
+ {
1491
+ "address": "clause-4.9.6/s7",
1492
+ "fragment": "clause-4.9.6",
1493
+ "clause": "4.9.6",
1494
+ "kind": "provision",
1495
+ "fragment_normative": true,
1496
+ "modality": "informative",
1497
+ "text": "_________________________________________________________________________________"
1498
+ },
1499
+ {
1500
+ "address": "clause-4.9.6/s8",
1501
+ "fragment": "clause-4.9.6",
1502
+ "clause": "4.9.6",
1503
+ "kind": "provision",
1504
+ "fragment_normative": true,
1505
+ "modality": "informative",
1506
+ "text": "_________________________________________________________________________________"
1507
+ },
1508
+ {
1509
+ "address": "clause-4.9.9/s1",
1510
+ "fragment": "clause-4.9.9",
1511
+ "clause": "4.9.9",
1512
+ "kind": "provision",
1513
+ "fragment_normative": true,
1514
+ "modality": "informative",
1515
+ "text": "(This table is to be completed by the manufacturer for each load cell family within the model range)"
1516
+ },
1517
+ {
1518
+ "address": "clause-4.9.9/s2",
1519
+ "fragment": "clause-4.9.9",
1520
+ "clause": "4.9.9",
1521
+ "kind": "provision",
1522
+ "fragment_normative": true,
1523
+ "modality": "informative",
1524
+ "text": "Further remarks concerning the definition of load cell families / construction (see table above)"
1525
+ },
1526
+ {
1527
+ "address": "clause-4.9.9/s3",
1528
+ "fragment": "clause-4.9.9",
1529
+ "clause": "4.9.9",
1530
+ "kind": "provision",
1531
+ "fragment_normative": true,
1532
+ "modality": "informative",
1533
+ "text": "_________________________________________________________________________________"
1534
+ },
1535
+ {
1536
+ "address": "clause-4.9.9/s4",
1537
+ "fragment": "clause-4.9.9",
1538
+ "clause": "4.9.9",
1539
+ "kind": "provision",
1540
+ "fragment_normative": true,
1541
+ "modality": "informative",
1542
+ "text": "_________________________________________________________________________________"
1543
+ },
1544
+ {
1545
+ "address": "clause-4.9.9/s5",
1546
+ "fragment": "clause-4.9.9",
1547
+ "clause": "4.9.9",
1548
+ "kind": "provision",
1549
+ "fragment_normative": true,
1550
+ "modality": "informative",
1551
+ "text": "_________________________________________________________________________________"
1552
+ },
1553
+ {
1554
+ "address": "clause-4.9.9/s6",
1555
+ "fragment": "clause-4.9.9",
1556
+ "clause": "4.9.9",
1557
+ "kind": "provision",
1558
+ "fragment_normative": true,
1559
+ "modality": "informative",
1560
+ "text": "_________________________________________________________________________________"
1561
+ },
1562
+ {
1563
+ "address": "clause-4.9.9/s7",
1564
+ "fragment": "clause-4.9.9",
1565
+ "clause": "4.9.9",
1566
+ "kind": "provision",
1567
+ "fragment_normative": true,
1568
+ "modality": "informative",
1569
+ "text": "_________________________________________________________________________________"
1570
+ },
1571
+ {
1572
+ "address": "clause-4.9.9/s8",
1573
+ "fragment": "clause-4.9.9",
1574
+ "clause": "4.9.9",
1575
+ "kind": "provision",
1576
+ "fragment_normative": true,
1577
+ "modality": "informative",
1578
+ "text": "_________________________________________________________________________________"
1579
+ },
1580
+ {
1581
+ "address": "clause-4.10/s1",
1582
+ "fragment": "clause-4.10",
1583
+ "clause": "4.10",
1584
+ "kind": "provision",
1585
+ "fragment_normative": true,
1586
+ "modality": "informative",
1587
+ "text": "(including details of simulations and the way uncertainties are taken into account, including the level of “risk.”"
1588
+ },
1589
+ {
1590
+ "address": "clause-4.10/s2",
1591
+ "fragment": "clause-4.10",
1592
+ "clause": "4.10",
1593
+ "kind": "provision",
1594
+ "fragment_normative": true,
1595
+ "modality": "informative",
1596
+ "text": "For instance, 95 % or k = 2)"
1597
+ },
1598
+ {
1599
+ "address": "clause-4.10/s3",
1600
+ "fragment": "clause-4.10",
1601
+ "clause": "4.10",
1602
+ "kind": "provision",
1603
+ "fragment_normative": true,
1604
+ "modality": "informative",
1605
+ "text": "The following tables have to be completed for each individual piece of test equipment used for the tests."
1606
+ },
1607
+ {
1608
+ "address": "clause-4.10/s4",
1609
+ "fragment": "clause-4.10",
1610
+ "clause": "4.10",
1611
+ "kind": "provision",
1612
+ "fragment_normative": true,
1613
+ "modality": "informative",
1614
+ "text": "General information:"
1615
+ },
1616
+ {
1617
+ "address": "clause-4.10/s5",
1618
+ "fragment": "clause-4.10",
1619
+ "clause": "4.10",
1620
+ "kind": "provision",
1621
+ "fragment_normative": true,
1622
+ "modality": "informative",
1623
+ "text": "For each of the following pieces of test equipment, indicate for which of the following test procedures the test equipment is used:"
1624
+ },
1625
+ {
1626
+ "address": "clause-4.10/s6",
1627
+ "fragment": "clause-4.10",
1628
+ "clause": "4.10",
1629
+ "kind": "provision",
1630
+ "fragment_normative": true,
1631
+ "modality": "informative",
1632
+ "text": "A piece of test equipment is used for determination of the measurement error (R 60-2, 2.10.1), the creep error (R 60-2, 2.10.2), the minimum dead load output return (R 60-2, 2.10.3) and humidity effect marked with SH (R 60-2, 2.10.6): R 60-2 reference 2.10.1 2.10.2 2.10.3 2.10.4 2.10.5 2.10.5 2.10.6 2.10.7 Used for"
1633
+ },
1634
+ {
1635
+ "address": "clause-4.10.1/s1",
1636
+ "fragment": "clause-4.10.1",
1637
+ "clause": "4.10.1",
1638
+ "kind": "provision",
1639
+ "fragment_normative": true,
1640
+ "modality": "informative",
1641
+ "text": "The force generating system is used for the following test procedures:"
1642
+ },
1643
+ {
1644
+ "address": "clause-4.10.1/s2",
1645
+ "fragment": "clause-4.10.1",
1646
+ "clause": "4.10.1",
1647
+ "kind": "provision",
1648
+ "fragment_normative": true,
1649
+ "modality": "informative",
1650
+ "text": "Remarks / picture of the force generating system:"
1651
+ },
1652
+ {
1653
+ "address": "clause-4.10.1/s3",
1654
+ "fragment": "clause-4.10.1",
1655
+ "clause": "4.10.1",
1656
+ "kind": "provision",
1657
+ "fragment_normative": true,
1658
+ "modality": "informative",
1659
+ "text": "_________________________________________________________________________________"
1660
+ },
1661
+ {
1662
+ "address": "clause-4.10.1/s4",
1663
+ "fragment": "clause-4.10.1",
1664
+ "clause": "4.10.1",
1665
+ "kind": "provision",
1666
+ "fragment_normative": true,
1667
+ "modality": "informative",
1668
+ "text": "_________________________________________________________________________________"
1669
+ },
1670
+ {
1671
+ "address": "clause-4.10.1/s5",
1672
+ "fragment": "clause-4.10.1",
1673
+ "clause": "4.10.1",
1674
+ "kind": "provision",
1675
+ "fragment_normative": true,
1676
+ "modality": "informative",
1677
+ "text": "_________________________________________________________________________________"
1678
+ },
1679
+ {
1680
+ "address": "clause-4.10.1/s6",
1681
+ "fragment": "clause-4.10.1",
1682
+ "clause": "4.10.1",
1683
+ "kind": "provision",
1684
+ "fragment_normative": true,
1685
+ "modality": "informative",
1686
+ "text": "_________________________________________________________________________________"
1687
+ },
1688
+ {
1689
+ "address": "clause-4.10.1/s7",
1690
+ "fragment": "clause-4.10.1",
1691
+ "clause": "4.10.1",
1692
+ "kind": "provision",
1693
+ "fragment_normative": true,
1694
+ "modality": "informative",
1695
+ "text": "_________________________________________________________________________________"
1696
+ },
1697
+ {
1698
+ "address": "clause-4.10.1/s8",
1699
+ "fragment": "clause-4.10.1",
1700
+ "clause": "4.10.1",
1701
+ "kind": "provision",
1702
+ "fragment_normative": true,
1703
+ "modality": "informative",
1704
+ "text": "_________________________________________________________________________________"
1705
+ },
1706
+ {
1707
+ "address": "clause-4.10.2/s1",
1708
+ "fragment": "clause-4.10.2",
1709
+ "clause": "4.10.2",
1710
+ "kind": "provision",
1711
+ "fragment_normative": true,
1712
+ "modality": "informative",
1713
+ "text": "(if the load cell is tested manually with weights)"
1714
+ },
1715
+ {
1716
+ "address": "clause-4.10.2/s2",
1717
+ "fragment": "clause-4.10.2",
1718
+ "clause": "4.10.2",
1719
+ "kind": "provision",
1720
+ "fragment_normative": true,
1721
+ "modality": "informative",
1722
+ "text": "The weights are used for the following test procedures:"
1723
+ },
1724
+ {
1725
+ "address": "clause-4.10.2/s3",
1726
+ "fragment": "clause-4.10.2",
1727
+ "clause": "4.10.2",
1728
+ "kind": "provision",
1729
+ "fragment_normative": true,
1730
+ "modality": "informative",
1731
+ "text": "Remarks / picture of the weights:"
1732
+ },
1733
+ {
1734
+ "address": "clause-4.10.2/s4",
1735
+ "fragment": "clause-4.10.2",
1736
+ "clause": "4.10.2",
1737
+ "kind": "provision",
1738
+ "fragment_normative": true,
1739
+ "modality": "informative",
1740
+ "text": "_________________________________________________________________________________"
1741
+ },
1742
+ {
1743
+ "address": "clause-4.10.2/s5",
1744
+ "fragment": "clause-4.10.2",
1745
+ "clause": "4.10.2",
1746
+ "kind": "provision",
1747
+ "fragment_normative": true,
1748
+ "modality": "informative",
1749
+ "text": "_________________________________________________________________________________"
1750
+ },
1751
+ {
1752
+ "address": "clause-4.10.2/s6",
1753
+ "fragment": "clause-4.10.2",
1754
+ "clause": "4.10.2",
1755
+ "kind": "provision",
1756
+ "fragment_normative": true,
1757
+ "modality": "informative",
1758
+ "text": "_________________________________________________________________________________"
1759
+ },
1760
+ {
1761
+ "address": "clause-4.10.2/s7",
1762
+ "fragment": "clause-4.10.2",
1763
+ "clause": "4.10.2",
1764
+ "kind": "provision",
1765
+ "fragment_normative": true,
1766
+ "modality": "informative",
1767
+ "text": "_________________________________________________________________________________"
1768
+ },
1769
+ {
1770
+ "address": "clause-4.10.2/s8",
1771
+ "fragment": "clause-4.10.2",
1772
+ "clause": "4.10.2",
1773
+ "kind": "provision",
1774
+ "fragment_normative": true,
1775
+ "modality": "informative",
1776
+ "text": "_________________________________________________________________________________"
1777
+ },
1778
+ {
1779
+ "address": "clause-4.10.2/s9",
1780
+ "fragment": "clause-4.10.2",
1781
+ "clause": "4.10.2",
1782
+ "kind": "provision",
1783
+ "fragment_normative": true,
1784
+ "modality": "informative",
1785
+ "text": "_________________________________________________________________________________"
1786
+ },
1787
+ {
1788
+ "address": "clause-4.10.3/s1",
1789
+ "fragment": "clause-4.10.3",
1790
+ "clause": "4.10.3",
1791
+ "kind": "provision",
1792
+ "fragment_normative": true,
1793
+ "modality": "informative",
1794
+ "text": "The climate chamber is used for the following test procedures:"
1795
+ },
1796
+ {
1797
+ "address": "clause-4.10.3/s2",
1798
+ "fragment": "clause-4.10.3",
1799
+ "clause": "4.10.3",
1800
+ "kind": "provision",
1801
+ "fragment_normative": true,
1802
+ "modality": "informative",
1803
+ "text": "Remarks / picture of the temperature chamber:"
1804
+ },
1805
+ {
1806
+ "address": "clause-4.10.3/s3",
1807
+ "fragment": "clause-4.10.3",
1808
+ "clause": "4.10.3",
1809
+ "kind": "provision",
1810
+ "fragment_normative": true,
1811
+ "modality": "informative",
1812
+ "text": "_________________________________________________________________________________"
1813
+ },
1814
+ {
1815
+ "address": "clause-4.10.3/s4",
1816
+ "fragment": "clause-4.10.3",
1817
+ "clause": "4.10.3",
1818
+ "kind": "provision",
1819
+ "fragment_normative": true,
1820
+ "modality": "informative",
1821
+ "text": "_________________________________________________________________________________"
1822
+ },
1823
+ {
1824
+ "address": "clause-4.10.3/s5",
1825
+ "fragment": "clause-4.10.3",
1826
+ "clause": "4.10.3",
1827
+ "kind": "provision",
1828
+ "fragment_normative": true,
1829
+ "modality": "informative",
1830
+ "text": "_________________________________________________________________________________"
1831
+ },
1832
+ {
1833
+ "address": "clause-4.10.3/s6",
1834
+ "fragment": "clause-4.10.3",
1835
+ "clause": "4.10.3",
1836
+ "kind": "provision",
1837
+ "fragment_normative": true,
1838
+ "modality": "informative",
1839
+ "text": "_________________________________________________________________________________"
1840
+ },
1841
+ {
1842
+ "address": "clause-4.10.3/s7",
1843
+ "fragment": "clause-4.10.3",
1844
+ "clause": "4.10.3",
1845
+ "kind": "provision",
1846
+ "fragment_normative": true,
1847
+ "modality": "informative",
1848
+ "text": "_________________________________________________________________________________"
1849
+ },
1850
+ {
1851
+ "address": "clause-4.10.3/s8",
1852
+ "fragment": "clause-4.10.3",
1853
+ "clause": "4.10.3",
1854
+ "kind": "provision",
1855
+ "fragment_normative": true,
1856
+ "modality": "informative",
1857
+ "text": "_________________________________________________________________________________"
1858
+ },
1859
+ {
1860
+ "address": "clause-4.10.4/s1",
1861
+ "fragment": "clause-4.10.4",
1862
+ "clause": "4.10.4",
1863
+ "kind": "provision",
1864
+ "fragment_normative": true,
1865
+ "modality": "informative",
1866
+ "text": "The climate chamber is used for the following test procedures:"
1867
+ },
1868
+ {
1869
+ "address": "clause-4.10.4/s2",
1870
+ "fragment": "clause-4.10.4",
1871
+ "clause": "4.10.4",
1872
+ "kind": "provision",
1873
+ "fragment_normative": true,
1874
+ "modality": "informative",
1875
+ "text": "Remarks / picture of the climate chamber:"
1876
+ },
1877
+ {
1878
+ "address": "clause-4.10.4/s3",
1879
+ "fragment": "clause-4.10.4",
1880
+ "clause": "4.10.4",
1881
+ "kind": "provision",
1882
+ "fragment_normative": true,
1883
+ "modality": "informative",
1884
+ "text": "_________________________________________________________________________________"
1885
+ },
1886
+ {
1887
+ "address": "clause-4.10.4/s4",
1888
+ "fragment": "clause-4.10.4",
1889
+ "clause": "4.10.4",
1890
+ "kind": "provision",
1891
+ "fragment_normative": true,
1892
+ "modality": "informative",
1893
+ "text": "_________________________________________________________________________________"
1894
+ },
1895
+ {
1896
+ "address": "clause-4.10.4/s5",
1897
+ "fragment": "clause-4.10.4",
1898
+ "clause": "4.10.4",
1899
+ "kind": "provision",
1900
+ "fragment_normative": true,
1901
+ "modality": "informative",
1902
+ "text": "_________________________________________________________________________________"
1903
+ },
1904
+ {
1905
+ "address": "clause-4.10.4/s6",
1906
+ "fragment": "clause-4.10.4",
1907
+ "clause": "4.10.4",
1908
+ "kind": "provision",
1909
+ "fragment_normative": true,
1910
+ "modality": "informative",
1911
+ "text": "_________________________________________________________________________________"
1912
+ },
1913
+ {
1914
+ "address": "clause-4.10.4/s7",
1915
+ "fragment": "clause-4.10.4",
1916
+ "clause": "4.10.4",
1917
+ "kind": "provision",
1918
+ "fragment_normative": true,
1919
+ "modality": "informative",
1920
+ "text": "_________________________________________________________________________________"
1921
+ },
1922
+ {
1923
+ "address": "clause-4.10.4/s8",
1924
+ "fragment": "clause-4.10.4",
1925
+ "clause": "4.10.4",
1926
+ "kind": "provision",
1927
+ "fragment_normative": true,
1928
+ "modality": "informative",
1929
+ "text": "_________________________________________________________________________________"
1930
+ },
1931
+ {
1932
+ "address": "clause-4.10.5/s1",
1933
+ "fragment": "clause-4.10.5",
1934
+ "clause": "4.10.5",
1935
+ "kind": "provision",
1936
+ "fragment_normative": true,
1937
+ "modality": "informative",
1938
+ "text": "(for testing analogue load cells)"
1939
+ },
1940
+ {
1941
+ "address": "clause-4.10.5/s2",
1942
+ "fragment": "clause-4.10.5",
1943
+ "clause": "4.10.5",
1944
+ "kind": "provision",
1945
+ "fragment_normative": true,
1946
+ "modality": "informative",
1947
+ "text": "Settings of the indicator / indicating instrument used for the tests"
1948
+ },
1949
+ {
1950
+ "address": "clause-4.10.5/s3",
1951
+ "fragment": "clause-4.10.5",
1952
+ "clause": "4.10.5",
1953
+ "kind": "provision",
1954
+ "fragment_normative": true,
1955
+ "modality": "informative",
1956
+ "text": "The indicator / indicating instrument is used for the following test procedures:"
1957
+ },
1958
+ {
1959
+ "address": "clause-4.10.5/s4",
1960
+ "fragment": "clause-4.10.5",
1961
+ "clause": "4.10.5",
1962
+ "kind": "provision",
1963
+ "fragment_normative": true,
1964
+ "modality": "informative",
1965
+ "text": "Remarks / picture of the indicator / indicating instrument:"
1966
+ },
1967
+ {
1968
+ "address": "clause-4.10.5/s5",
1969
+ "fragment": "clause-4.10.5",
1970
+ "clause": "4.10.5",
1971
+ "kind": "provision",
1972
+ "fragment_normative": true,
1973
+ "modality": "informative",
1974
+ "text": "_________________________________________________________________________________"
1975
+ },
1976
+ {
1977
+ "address": "clause-4.10.5/s6",
1978
+ "fragment": "clause-4.10.5",
1979
+ "clause": "4.10.5",
1980
+ "kind": "provision",
1981
+ "fragment_normative": true,
1982
+ "modality": "informative",
1983
+ "text": "_________________________________________________________________________________"
1984
+ },
1985
+ {
1986
+ "address": "clause-4.10.5/s7",
1987
+ "fragment": "clause-4.10.5",
1988
+ "clause": "4.10.5",
1989
+ "kind": "provision",
1990
+ "fragment_normative": true,
1991
+ "modality": "informative",
1992
+ "text": "_________________________________________________________________________________"
1993
+ },
1994
+ {
1995
+ "address": "clause-4.10.5/s8",
1996
+ "fragment": "clause-4.10.5",
1997
+ "clause": "4.10.5",
1998
+ "kind": "provision",
1999
+ "fragment_normative": true,
2000
+ "modality": "informative",
2001
+ "text": "_________________________________________________________________________________"
2002
+ },
2003
+ {
2004
+ "address": "clause-4.10.5/s9",
2005
+ "fragment": "clause-4.10.5",
2006
+ "clause": "4.10.5",
2007
+ "kind": "provision",
2008
+ "fragment_normative": true,
2009
+ "modality": "informative",
2010
+ "text": "_________________________________________________________________________________"
2011
+ },
2012
+ {
2013
+ "address": "clause-4.10.5/s10",
2014
+ "fragment": "clause-4.10.5",
2015
+ "clause": "4.10.5",
2016
+ "kind": "provision",
2017
+ "fragment_normative": true,
2018
+ "modality": "informative",
2019
+ "text": "_________________________________________________________________________________"
2020
+ },
2021
+ {
2022
+ "address": "clause-4.10.6/s1",
2023
+ "fragment": "clause-4.10.6",
2024
+ "clause": "4.10.6",
2025
+ "kind": "provision",
2026
+ "fragment_normative": true,
2027
+ "modality": "informative",
2028
+ "text": "(for testing digital load cells)"
2029
+ },
2030
+ {
2031
+ "address": "clause-4.10.6/s2",
2032
+ "fragment": "clause-4.10.6",
2033
+ "clause": "4.10.6",
2034
+ "kind": "provision",
2035
+ "fragment_normative": true,
2036
+ "modality": "informative",
2037
+ "text": "Settings of the indicator / indicating instrument used for the tests"
2038
+ },
2039
+ {
2040
+ "address": "clause-4.10.6/s3",
2041
+ "fragment": "clause-4.10.6",
2042
+ "clause": "4.10.6",
2043
+ "kind": "provision",
2044
+ "fragment_normative": true,
2045
+ "modality": "informative",
2046
+ "text": "The terminal / digital data processing device is used for the following test procedures:"
2047
+ },
2048
+ {
2049
+ "address": "clause-4.10.6/s4",
2050
+ "fragment": "clause-4.10.6",
2051
+ "clause": "4.10.6",
2052
+ "kind": "provision",
2053
+ "fragment_normative": true,
2054
+ "modality": "informative",
2055
+ "text": "Remarks / picture of the terminal / digital data processing device:"
2056
+ },
2057
+ {
2058
+ "address": "clause-4.10.6/s5",
2059
+ "fragment": "clause-4.10.6",
2060
+ "clause": "4.10.6",
2061
+ "kind": "provision",
2062
+ "fragment_normative": true,
2063
+ "modality": "informative",
2064
+ "text": "_________________________________________________________________________________"
2065
+ },
2066
+ {
2067
+ "address": "clause-4.10.6/s6",
2068
+ "fragment": "clause-4.10.6",
2069
+ "clause": "4.10.6",
2070
+ "kind": "provision",
2071
+ "fragment_normative": true,
2072
+ "modality": "informative",
2073
+ "text": "_________________________________________________________________________________"
2074
+ },
2075
+ {
2076
+ "address": "clause-4.10.6/s7",
2077
+ "fragment": "clause-4.10.6",
2078
+ "clause": "4.10.6",
2079
+ "kind": "provision",
2080
+ "fragment_normative": true,
2081
+ "modality": "informative",
2082
+ "text": "_________________________________________________________________________________"
2083
+ },
2084
+ {
2085
+ "address": "clause-4.10.6/s8",
2086
+ "fragment": "clause-4.10.6",
2087
+ "clause": "4.10.6",
2088
+ "kind": "provision",
2089
+ "fragment_normative": true,
2090
+ "modality": "informative",
2091
+ "text": "_________________________________________________________________________________"
2092
+ },
2093
+ {
2094
+ "address": "clause-4.10.6/s9",
2095
+ "fragment": "clause-4.10.6",
2096
+ "clause": "4.10.6",
2097
+ "kind": "provision",
2098
+ "fragment_normative": true,
2099
+ "modality": "informative",
2100
+ "text": "_________________________________________________________________________________"
2101
+ },
2102
+ {
2103
+ "address": "clause-4.10.6/s10",
2104
+ "fragment": "clause-4.10.6",
2105
+ "clause": "4.10.6",
2106
+ "kind": "provision",
2107
+ "fragment_normative": true,
2108
+ "modality": "informative",
2109
+ "text": "_________________________________________________________________________________"
2110
+ },
2111
+ {
2112
+ "address": "clause-4.10.7/s1",
2113
+ "fragment": "clause-4.10.7",
2114
+ "clause": "4.10.7",
2115
+ "kind": "provision",
2116
+ "fragment_normative": true,
2117
+ "modality": "informative",
2118
+ "text": "The barometric pressure meter is used for the following test procedures:"
2119
+ },
2120
+ {
2121
+ "address": "clause-4.10.8/s1",
2122
+ "fragment": "clause-4.10.8",
2123
+ "clause": "4.10.8",
2124
+ "kind": "provision",
2125
+ "fragment_normative": true,
2126
+ "modality": "informative",
2127
+ "text": "The thermometer is used for the following test procedures:"
2128
+ },
2129
+ {
2130
+ "address": "clause-4.10.9/s1",
2131
+ "fragment": "clause-4.10.9",
2132
+ "clause": "4.10.9",
2133
+ "kind": "provision",
2134
+ "fragment_normative": true,
2135
+ "modality": "informative",
2136
+ "text": "The moisture analyser is used for the following test procedures"
2137
+ },
2138
+ {
2139
+ "address": "clause-4.10.10/s1",
2140
+ "fragment": "clause-4.10.10",
2141
+ "clause": "4.10.10",
2142
+ "kind": "provision",
2143
+ "fragment_normative": true,
2144
+ "modality": "informative",
2145
+ "text": "(e.g. burst generator for testing of digital load cells)"
2146
+ },
2147
+ {
2148
+ "address": "clause-4.10.10/s2",
2149
+ "fragment": "clause-4.10.10",
2150
+ "clause": "4.10.10",
2151
+ "kind": "provision",
2152
+ "fragment_normative": true,
2153
+ "modality": "informative",
2154
+ "text": "The equipment is used for the following test procedures:"
2155
+ },
2156
+ {
2157
+ "address": "clause-4.10.11/s1",
2158
+ "fragment": "clause-4.10.11",
2159
+ "clause": "4.10.11",
2160
+ "kind": "provision",
2161
+ "fragment_normative": true,
2162
+ "modality": "informative",
2163
+ "text": "_________________________________________________________________________________"
2164
+ },
2165
+ {
2166
+ "address": "clause-4.10.11/s2",
2167
+ "fragment": "clause-4.10.11",
2168
+ "clause": "4.10.11",
2169
+ "kind": "provision",
2170
+ "fragment_normative": true,
2171
+ "modality": "informative",
2172
+ "text": "_________________________________________________________________________________"
2173
+ },
2174
+ {
2175
+ "address": "clause-4.10.11/s3",
2176
+ "fragment": "clause-4.10.11",
2177
+ "clause": "4.10.11",
2178
+ "kind": "provision",
2179
+ "fragment_normative": true,
2180
+ "modality": "informative",
2181
+ "text": "_________________________________________________________________________________"
2182
+ },
2183
+ {
2184
+ "address": "clause-4.10.11/s4",
2185
+ "fragment": "clause-4.10.11",
2186
+ "clause": "4.10.11",
2187
+ "kind": "provision",
2188
+ "fragment_normative": true,
2189
+ "modality": "informative",
2190
+ "text": "_________________________________________________________________________________"
2191
+ },
2192
+ {
2193
+ "address": "clause-4.10.11/s5",
2194
+ "fragment": "clause-4.10.11",
2195
+ "clause": "4.10.11",
2196
+ "kind": "provision",
2197
+ "fragment_normative": true,
2198
+ "modality": "informative",
2199
+ "text": "_________________________________________________________________________________"
2200
+ },
2201
+ {
2202
+ "address": "clause-4.10.11/s6",
2203
+ "fragment": "clause-4.10.11",
2204
+ "clause": "4.10.11",
2205
+ "kind": "provision",
2206
+ "fragment_normative": true,
2207
+ "modality": "informative",
2208
+ "text": "_________________________________________________________________________________"
2209
+ },
2210
+ {
2211
+ "address": "clause-5/s1",
2212
+ "fragment": "clause-5",
2213
+ "clause": "5",
2214
+ "kind": "provision",
2215
+ "fragment_normative": true,
2216
+ "modality": "informative",
2217
+ "text": "(To be completed by the Evaluating Authority)"
2218
+ },
2219
+ {
2220
+ "address": "clause-5.1.2/s1",
2221
+ "fragment": "clause-5.1.2",
2222
+ "clause": "5.1.2",
2223
+ "kind": "provision",
2224
+ "fragment_normative": true,
2225
+ "modality": "informative",
2226
+ "text": "(R 60-1, 6.2.2)"
2227
+ },
2228
+ {
2229
+ "address": "clause-6.1/s1",
2230
+ "fragment": "clause-6.1",
2231
+ "clause": "6.1",
2232
+ "kind": "provision",
2233
+ "fragment_normative": true,
2234
+ "modality": "informative",
2235
+ "text": "Remarks:"
2236
+ },
2237
+ {
2238
+ "address": "clause-6.1/s2",
2239
+ "fragment": "clause-6.1",
2240
+ "clause": "6.1",
2241
+ "kind": "provision",
2242
+ "fragment_normative": true,
2243
+ "modality": "informative",
2244
+ "text": "_________________________________________________________________________________"
2245
+ },
2246
+ {
2247
+ "address": "clause-6.1/s3",
2248
+ "fragment": "clause-6.1",
2249
+ "clause": "6.1",
2250
+ "kind": "provision",
2251
+ "fragment_normative": true,
2252
+ "modality": "informative",
2253
+ "text": "_________________________________________________________________________________"
2254
+ },
2255
+ {
2256
+ "address": "clause-6.1/s4",
2257
+ "fragment": "clause-6.1",
2258
+ "clause": "6.1",
2259
+ "kind": "provision",
2260
+ "fragment_normative": true,
2261
+ "modality": "informative",
2262
+ "text": "_________________________________________________________________________________"
2263
+ },
2264
+ {
2265
+ "address": "clause-6.1/s5",
2266
+ "fragment": "clause-6.1",
2267
+ "clause": "6.1",
2268
+ "kind": "provision",
2269
+ "fragment_normative": true,
2270
+ "modality": "informative",
2271
+ "text": "_________________________________________________________________________________"
2272
+ },
2273
+ {
2274
+ "address": "clause-6.1/table-1/note-1/s1",
2275
+ "fragment": "clause-6.1/table-1/note-1",
2276
+ "kind": "note",
2277
+ "fragment_normative": false,
2278
+ "modality": "informative",
2279
+ "text": "DR is the minimum dead load output return in units of (\"unitsml(g)\", \"unitsml(kg)\", \"unitsml(t)\") and determined according to R 60-3, 2.1.5.8"
2280
+ },
2281
+ {
2282
+ "address": "clause-6.1/table-1/note-2/s1",
2283
+ "fragment": "clause-6.1/table-1/note-2",
2284
+ "kind": "note",
2285
+ "fragment_normative": false,
2286
+ "modality": "informative",
2287
+ "text": "Maximum error in unit v_{\"min\"}"
2288
+ },
2289
+ {
2290
+ "address": "clause-6.1.1/s1",
2291
+ "fragment": "clause-6.1.1",
2292
+ "clause": "6.1.1",
2293
+ "kind": "provision",
2294
+ "fragment_normative": true,
2295
+ "modality": "informative",
2296
+ "text": "Remarks:"
2297
+ },
2298
+ {
2299
+ "address": "clause-6.1.1/s2",
2300
+ "fragment": "clause-6.1.1",
2301
+ "clause": "6.1.1",
2302
+ "kind": "provision",
2303
+ "fragment_normative": true,
2304
+ "modality": "informative",
2305
+ "text": "_________________________________________________________________________________"
2306
+ },
2307
+ {
2308
+ "address": "clause-6.1.1/s3",
2309
+ "fragment": "clause-6.1.1",
2310
+ "clause": "6.1.1",
2311
+ "kind": "provision",
2312
+ "fragment_normative": true,
2313
+ "modality": "informative",
2314
+ "text": "_________________________________________________________________________________"
2315
+ },
2316
+ {
2317
+ "address": "clause-6.1.1/s4",
2318
+ "fragment": "clause-6.1.1",
2319
+ "clause": "6.1.1",
2320
+ "kind": "provision",
2321
+ "fragment_normative": true,
2322
+ "modality": "informative",
2323
+ "text": "_________________________________________________________________________________"
2324
+ },
2325
+ {
2326
+ "address": "clause-6.1.1/s5",
2327
+ "fragment": "clause-6.1.1",
2328
+ "clause": "6.1.1",
2329
+ "kind": "provision",
2330
+ "fragment_normative": true,
2331
+ "modality": "informative",
2332
+ "text": "_________________________________________________________________________________"
2333
+ },
2334
+ {
2335
+ "address": "clause-6.2/s1",
2336
+ "fragment": "clause-6.2",
2337
+ "clause": "6.2",
2338
+ "kind": "provision",
2339
+ "fragment_normative": true,
2340
+ "modality": "informative",
2341
+ "text": "(To be completed or under the responsibility of the Evaluating Authority)"
2342
+ },
2343
+ {
2344
+ "address": "clause-6.2.1/s1",
2345
+ "fragment": "clause-6.2.1",
2346
+ "clause": "6.2.1",
2347
+ "kind": "provision",
2348
+ "fragment_normative": true,
2349
+ "modality": "informative",
2350
+ "text": "Unit (e.g. counts, digits, g, kg, t) in which the measurement result is displayed."
2351
+ },
2352
+ {
2353
+ "address": "clause-6.2.3/s1",
2354
+ "fragment": "clause-6.2.3",
2355
+ "clause": "6.2.3",
2356
+ "kind": "provision",
2357
+ "fragment_normative": true,
2358
+ "modality": "informative",
2359
+ "text": "(see R 60-2, 2.8.1)"
2360
+ },
2361
+ {
2362
+ "address": "clause-6.2.3/s2",
2363
+ "fragment": "clause-6.2.3",
2364
+ "clause": "6.2.3",
2365
+ "kind": "provision",
2366
+ "fragment_normative": true,
2367
+ "modality": "normative",
2368
+ "text": "(To ensure that these requirements are met, the calculations should be carried out using lower n values than the n_{\"LC\"} specified."
2369
+ },
2370
+ {
2371
+ "address": "clause-6.2.3/s3",
2372
+ "fragment": "clause-6.2.3",
2373
+ "clause": "6.2.3",
2374
+ "kind": "provision",
2375
+ "fragment_normative": true,
2376
+ "modality": "informative",
2377
+ "text": "The calculations made do not include the application of 2.8.1)."
2378
+ },
2379
+ {
2380
+ "address": "clause-6.2.3/s4",
2381
+ "fragment": "clause-6.2.3",
2382
+ "clause": "6.2.3",
2383
+ "kind": "provision",
2384
+ "fragment_normative": true,
2385
+ "modality": "informative",
2386
+ "text": "Check that"
2387
+ },
2388
+ {
2389
+ "address": "clause-6.2.3/s5",
2390
+ "fragment": "clause-6.2.3",
2391
+ "clause": "6.2.3",
2392
+ "kind": "provision",
2393
+ "fragment_normative": true,
2394
+ "modality": "informative",
2395
+ "text": "v_{\"min\"} <= {D_{\"max\"} - D_{\"min\"}} / n"
2396
+ },
2397
+ {
2398
+ "address": "clause-6.2.3/s6",
2399
+ "fragment": "clause-6.2.3",
2400
+ "clause": "6.2.3",
2401
+ "kind": "provision",
2402
+ "fragment_normative": true,
2403
+ "modality": "normative",
2404
+ "text": "It should be sufficient to carry out the calculations with n = n_{\"LC\"}, n_{\"max\"} - 500 and n = n_{\"LC\"} - 1000 if applicable."
2405
+ },
2406
+ {
2407
+ "address": "clause-6.2.3/s7",
2408
+ "fragment": "clause-6.2.3",
2409
+ "clause": "6.2.3",
2410
+ "kind": "provision",
2411
+ "fragment_normative": true,
2412
+ "modality": "informative",
2413
+ "text": "Passed ☐ Yes ☐ No"
2414
+ },
2415
+ {
2416
+ "address": "clause-6.2.4/s1",
2417
+ "fragment": "clause-6.2.4",
2418
+ "clause": "6.2.4",
2419
+ "kind": "provision",
2420
+ "fragment_normative": true,
2421
+ "modality": "informative",
2422
+ "text": "Measure the input impedance and compare the result with the input impedance in OIML R 60-3, 4.5."
2423
+ },
2424
+ {
2425
+ "address": "clause-6.3/s1",
2426
+ "fragment": "clause-6.3",
2427
+ "clause": "6.3",
2428
+ "kind": "provision",
2429
+ "fragment_normative": true,
2430
+ "modality": "informative",
2431
+ "text": "Ref.: R 60-2, 2.10.1.1 to 2.10.1.11."
2432
+ },
2433
+ {
2434
+ "address": "clause-6.3/s2",
2435
+ "fragment": "clause-6.3",
2436
+ "clause": "6.3",
2437
+ "kind": "provision",
2438
+ "fragment_normative": true,
2439
+ "modality": "informative",
2440
+ "text": "Complete one sheet for each test temperature, one for each humidity (SH) test in 2.10.6, and when applicable, one for each electronics power voltage in 2.10.7.4."
2441
+ },
2442
+ {
2443
+ "address": "clause-6.3/s3",
2444
+ "fragment": "clause-6.3",
2445
+ "clause": "6.3",
2446
+ "kind": "provision",
2447
+ "fragment_normative": true,
2448
+ "modality": "informative",
2449
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Electronics power voltage (when applicable):"
2450
+ },
2451
+ {
2452
+ "address": "table-1/note-1/s1",
2453
+ "fragment": "table-1/note-1",
2454
+ "kind": "note",
2455
+ "fragment_normative": false,
2456
+ "modality": "informative",
2457
+ "text": "* = Average initial minimum test load indication."
2458
+ },
2459
+ {
2460
+ "address": "table-1/note-1/s2",
2461
+ "fragment": "table-1/note-1",
2462
+ "kind": "note",
2463
+ "fragment_normative": false,
2464
+ "modality": "informative",
2465
+ "text": "Absolute (not relative) time shall be recorded."
2466
+ },
2467
+ {
2468
+ "address": "clause-6.4/s1",
2469
+ "fragment": "clause-6.4",
2470
+ "clause": "6.4",
2471
+ "kind": "provision",
2472
+ "fragment_normative": true,
2473
+ "modality": "informative",
2474
+ "text": "R 60-2, 2.10.1.1 to 2.10.1.11."
2475
+ },
2476
+ {
2477
+ "address": "clause-6.4/s2",
2478
+ "fragment": "clause-6.4",
2479
+ "clause": "6.4",
2480
+ "kind": "provision",
2481
+ "fragment_normative": true,
2482
+ "modality": "informative",
2483
+ "text": "Complete one sheet for each test temperature, one for each humidity (SH) test in 2.10.6, and when applicable, one for each electronics power voltage in 2.10.7.4."
2484
+ },
2485
+ {
2486
+ "address": "clause-6.4/s3",
2487
+ "fragment": "clause-6.4",
2488
+ "clause": "6.4",
2489
+ "kind": "provision",
2490
+ "fragment_normative": true,
2491
+ "modality": "informative",
2492
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Electronics power voltage (when applicable):"
2493
+ },
2494
+ {
2495
+ "address": "table-2/note-1/s1",
2496
+ "fragment": "table-2/note-1",
2497
+ "kind": "note",
2498
+ "fragment_normative": false,
2499
+ "modality": "informative",
2500
+ "text": "* = Average initial minimum test load indication."
2501
+ },
2502
+ {
2503
+ "address": "table-2/note-1/s2",
2504
+ "fragment": "table-2/note-1",
2505
+ "kind": "note",
2506
+ "fragment_normative": false,
2507
+ "modality": "informative",
2508
+ "text": "Absolute (not relative) time shall be recorded."
2509
+ },
2510
+ {
2511
+ "address": "clause-6.5/s1",
2512
+ "fragment": "clause-6.5",
2513
+ "clause": "6.5",
2514
+ "kind": "provision",
2515
+ "fragment_normative": true,
2516
+ "modality": "informative",
2517
+ "text": "R 60-1, 5.3.1 R 60-2, 2.10.1.12 to 2.10.1.14 R 60-3, 2.1.2.2"
2518
+ },
2519
+ {
2520
+ "address": "clause-6.5/s2",
2521
+ "fragment": "clause-6.5",
2522
+ "clause": "6.5",
2523
+ "kind": "provision",
2524
+ "fragment_normative": true,
2525
+ "modality": "informative",
2526
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Conversion factor, f: 75 % test load (\"unitsml(g)\", \"unitsml(kg)\", \"unitsml(t)\"): Reference indication at 75 % test load:"
2527
+ },
2528
+ {
2529
+ "address": "clause-6.5/s3",
2530
+ "fragment": "clause-6.5",
2531
+ "clause": "6.5",
2532
+ "kind": "provision",
2533
+ "fragment_normative": true,
2534
+ "modality": "informative",
2535
+ "text": "Minimum test load, D_{\"min\"}: PASS: FAIL:"
2536
+ },
2537
+ {
2538
+ "address": "clause-6.5/note-1/s1",
2539
+ "fragment": "clause-6.5/note-1",
2540
+ "kind": "note",
2541
+ "fragment_normative": false,
2542
+ "modality": "informative",
2543
+ "text": "Load/reference indications: if a 75 % load point was not obtained, a straight line interpolation between the adjacent higher and lower load point indications is used (see R 60-1, 5.3.1 and calculation procedures in R 60-3, 2.1.2.2)."
2544
+ },
2545
+ {
2546
+ "address": "clause-6.5/note-1/s2",
2547
+ "fragment": "clause-6.5/note-1",
2548
+ "kind": "note",
2549
+ "fragment_normative": false,
2550
+ "modality": "informative",
2551
+ "text": "Error, E_{\"L\"}: the difference between the test indication and the reference indication divided by the conversion factor, f."
2552
+ },
2553
+ {
2554
+ "address": "clause-6.5/note-1/s3",
2555
+ "fragment": "clause-6.5/note-1",
2556
+ "kind": "note",
2557
+ "fragment_normative": false,
2558
+ "modality": "informative",
2559
+ "text": "Test load values are values above minimum test load, D_{\"min\"}."
2560
+ },
2561
+ {
2562
+ "address": "clause-6.6/s1",
2563
+ "fragment": "clause-6.6",
2564
+ "clause": "6.6",
2565
+ "kind": "provision",
2566
+ "fragment_normative": true,
2567
+ "modality": "informative",
2568
+ "text": "R 60-1, 5.4 R 60-2, 2.10.1.15 R 60-3, 2.1.3"
2569
+ },
2570
+ {
2571
+ "address": "clause-6.6/s2",
2572
+ "fragment": "clause-6.6",
2573
+ "clause": "6.6",
2574
+ "kind": "provision",
2575
+ "fragment_normative": true,
2576
+ "modality": "informative",
2577
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Conversion factor, f:"
2578
+ },
2579
+ {
2580
+ "address": "clause-6.6/s3",
2581
+ "fragment": "clause-6.6",
2582
+ "clause": "6.6",
2583
+ "kind": "provision",
2584
+ "fragment_normative": true,
2585
+ "modality": "informative",
2586
+ "text": "PASS: FAIL:"
2587
+ },
2588
+ {
2589
+ "address": "clause-6.6/note-1/s1",
2590
+ "fragment": "clause-6.6/note-1",
2591
+ "kind": "note",
2592
+ "fragment_normative": false,
2593
+ "modality": "informative",
2594
+ "text": "Error, E_R: the maximum difference between the three test indications divided by the conversion factor, f (classes C and D) or the maximum difference between the five test indications divided by the conversion factor, f (classes A and B)."
2595
+ },
2596
+ {
2597
+ "address": "clause-6.7/s1",
2598
+ "fragment": "clause-6.7",
2599
+ "clause": "6.7",
2600
+ "kind": "provision",
2601
+ "fragment_normative": true,
2602
+ "modality": "informative",
2603
+ "text": "R 60-1, 5.5.2 R 60-2, 2.10.1.16 R 60-3, 2.1.4"
2604
+ },
2605
+ {
2606
+ "address": "clause-6.7/s2",
2607
+ "fragment": "clause-6.7",
2608
+ "clause": "6.7",
2609
+ "kind": "provision",
2610
+ "fragment_normative": true,
2611
+ "modality": "informative",
2612
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Conversion factor, f:"
2613
+ },
2614
+ {
2615
+ "address": "clause-6.7/s3",
2616
+ "fragment": "clause-6.7",
2617
+ "clause": "6.7",
2618
+ "kind": "provision",
2619
+ "fragment_normative": true,
2620
+ "modality": "informative",
2621
+ "text": "PASS: ☐ FAIL: ☐"
2622
+ },
2623
+ {
2624
+ "address": "clause-6.7/note-1/s1",
2625
+ "fragment": "clause-6.7/note-1",
2626
+ "kind": "note",
2627
+ "fragment_normative": false,
2628
+ "modality": "informative",
2629
+ "text": "MDLO: minimum dead load output."
2630
+ },
2631
+ {
2632
+ "address": "clause-6.7/note-1/s2",
2633
+ "fragment": "clause-6.7/note-1",
2634
+ "kind": "note",
2635
+ "fragment_normative": false,
2636
+ "modality": "informative",
2637
+ "text": "Indication: the average initial minimum test load indication obtained from table-6.3."
2638
+ },
2639
+ {
2640
+ "address": "clause-6.7/note-1/s3",
2641
+ "fragment": "clause-6.7/note-1",
2642
+ "kind": "note",
2643
+ "fragment_normative": false,
2644
+ "modality": "informative",
2645
+ "text": "The maximum permissible change (mpc) allowed is: (v_{\"min\"} // 5 \"unitsml(degC)\") for classes B, C, and D; (v_{\"min\"} // 2 \"unitsml(degC)\") for class A."
2646
+ },
2647
+ {
2648
+ "address": "clause-6.7/note-1/s4",
2649
+ "fragment": "clause-6.7/note-1",
2650
+ "kind": "note",
2651
+ "fragment_normative": false,
2652
+ "modality": "informative",
2653
+ "text": "Change, C_{\"M\"} (v): the difference between the observed indications, and the indications at the prior temperature, divided by the conversion factor, f."
2654
+ },
2655
+ {
2656
+ "address": "clause-6.8/s1",
2657
+ "fragment": "clause-6.8",
2658
+ "clause": "6.8",
2659
+ "kind": "provision",
2660
+ "fragment_normative": true,
2661
+ "modality": "informative",
2662
+ "text": "R 60-1, 5.5.1, 5.5.2 R 60-2, 2.10.2, 2.10.3."
2663
+ },
2664
+ {
2665
+ "address": "clause-6.8/s2",
2666
+ "fragment": "clause-6.8",
2667
+ "clause": "6.8",
2668
+ "kind": "provision",
2669
+ "fragment_normative": true,
2670
+ "modality": "informative",
2671
+ "text": "Complete one sheet for each test temperature."
2672
+ },
2673
+ {
2674
+ "address": "clause-6.8/s3",
2675
+ "fragment": "clause-6.8",
2676
+ "clause": "6.8",
2677
+ "kind": "provision",
2678
+ "fragment_normative": true,
2679
+ "modality": "informative",
2680
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Conversion factor, f:"
2681
+ },
2682
+ {
2683
+ "address": "clause-6.8/s4",
2684
+ "fragment": "clause-6.8",
2685
+ "clause": "6.8",
2686
+ "kind": "provision",
2687
+ "fragment_normative": true,
2688
+ "modality": "informative",
2689
+ "text": "DR (v): 30 minute creep: PASS: FAIL: actual time (s): 20 — 30 minute creep difference (< 0.15*\"MPE\"): PASS: FAIL: specified time (s): DR < 0.5 v: PASS: FAIL: MPE for DR (v): DR within manuf."
2690
+ },
2691
+ {
2692
+ "address": "clause-6.8/s5",
2693
+ "fragment": "clause-6.8",
2694
+ "clause": "6.8",
2695
+ "kind": "provision",
2696
+ "fragment_normative": true,
2697
+ "modality": "informative",
2698
+ "text": "Specified DR requirements: PASS: FAIL:"
2699
+ },
2700
+ {
2701
+ "address": "clause-6.8/note-1/s1",
2702
+ "fragment": "clause-6.8/note-1",
2703
+ "kind": "note",
2704
+ "fragment_normative": false,
2705
+ "modality": "informative",
2706
+ "text": "Change (v) for creep: the observed indication minus the initial “load” indication (**) divided by the conversion factor, f."
2707
+ },
2708
+ {
2709
+ "address": "clause-6.8/note-1/s2",
2710
+ "fragment": "clause-6.8/note-1",
2711
+ "kind": "note",
2712
+ "fragment_normative": false,
2713
+ "modality": "informative",
2714
+ "text": "Determine the difference between the reading obtained at 20 minutes and the reading obtained at 30 minutes (see 5.5.1)."
2715
+ },
2716
+ {
2717
+ "address": "clause-6.8/note-1/s3",
2718
+ "fragment": "clause-6.8/note-1",
2719
+ "kind": "note",
2720
+ "fragment_normative": false,
2721
+ "modality": "informative",
2722
+ "text": "Change (v) for DR: the initial indication (***) minus the initial “no load” indication (*) divided by the conversion factor, f."
2723
+ },
2724
+ {
2725
+ "address": "clause-6.8/note-1/s4",
2726
+ "fragment": "clause-6.8/note-1",
2727
+ "kind": "note",
2728
+ "fragment_normative": false,
2729
+ "modality": "informative",
2730
+ "text": "Absolute (not relative) time shall be recorded."
2731
+ },
2732
+ {
2733
+ "address": "clause-6.9/s1",
2734
+ "fragment": "clause-6.9",
2735
+ "clause": "6.9",
2736
+ "kind": "provision",
2737
+ "fragment_normative": true,
2738
+ "modality": "informative",
2739
+ "text": "R 60-1, 5.6.2 R 60-2, 2.7.3.8, 2.10.4 R 60-3, 2.1.6"
2740
+ },
2741
+ {
2742
+ "address": "clause-6.9/s2",
2743
+ "fragment": "clause-6.9",
2744
+ "clause": "6.9",
2745
+ "kind": "provision",
2746
+ "fragment_normative": true,
2747
+ "modality": "informative",
2748
+ "text": "Complete one sheet for each test temperature."
2749
+ },
2750
+ {
2751
+ "address": "clause-6.9/s3",
2752
+ "fragment": "clause-6.9",
2753
+ "clause": "6.9",
2754
+ "kind": "provision",
2755
+ "fragment_normative": true,
2756
+ "modality": "informative",
2757
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: E_{\"min\"}: n_{\"LC\"}: p_{\"LC\"}: Y: Z: v_{\"min\"}: DR: Force-generating system: Test load:, D_{\"max\"}: D_{\"min\"}: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Conversion factor, f:"
2758
+ },
2759
+ {
2760
+ "address": "clause-6.9/s4",
2761
+ "fragment": "clause-6.9",
2762
+ "clause": "6.9",
2763
+ "kind": "provision",
2764
+ "fragment_normative": true,
2765
+ "modality": "informative",
2766
+ "text": "PASS: ☐ FAIL: ☐"
2767
+ },
2768
+ {
2769
+ "address": "clause-6.10.1/s1",
2770
+ "fragment": "clause-6.10.1",
2771
+ "clause": "6.10.1",
2772
+ "kind": "provision",
2773
+ "fragment_normative": true,
2774
+ "modality": "informative",
2775
+ "text": "R 60-1, 5.6.3 60-2, 2.7.3.9, 2.10.5 R 60-3, 2.1.7"
2776
+ },
2777
+ {
2778
+ "address": "clause-6.10.1.1/s1",
2779
+ "fragment": "clause-6.10.1.1",
2780
+ "clause": "6.10.1.1",
2781
+ "kind": "provision",
2782
+ "fragment_normative": true,
2783
+ "modality": "informative",
2784
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: E_{\"min\"}: n_{\"LC\"}: p_{\"LC\"}: Y: Z: v_{\"min\"}: DR: Force-generating system: Test load:, D_{\"max\"}: D_{\"min\"}: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Conversion factor, f:"
2785
+ },
2786
+ {
2787
+ "address": "clause-6.10.1.1/s2",
2788
+ "fragment": "clause-6.10.1.1",
2789
+ "clause": "6.10.1.1",
2790
+ "kind": "provision",
2791
+ "fragment_normative": true,
2792
+ "modality": "informative",
2793
+ "text": "(¤) Indications at minimum test load"
2794
+ },
2795
+ {
2796
+ "address": "clause-6.10.1.1/s3",
2797
+ "fragment": "clause-6.10.1.1",
2798
+ "clause": "6.10.1.1",
2799
+ "kind": "provision",
2800
+ "fragment_normative": true,
2801
+ "modality": "informative",
2802
+ "text": "Change (¤), C_{\"Hmin\"}: PASS: ☐ FAIL: ☐"
2803
+ },
2804
+ {
2805
+ "address": "clause-6.10.1.1/s4",
2806
+ "fragment": "clause-6.10.1.1",
2807
+ "clause": "6.10.1.1",
2808
+ "kind": "provision",
2809
+ "fragment_normative": true,
2810
+ "modality": "informative",
2811
+ "text": "(‡) Indications at maximum test load note_3"
2812
+ },
2813
+ {
2814
+ "address": "clause-6.10.1.1/s5",
2815
+ "fragment": "clause-6.10.1.1",
2816
+ "clause": "6.10.1.1",
2817
+ "kind": "provision",
2818
+ "fragment_normative": true,
2819
+ "modality": "informative",
2820
+ "text": "(*) Average, see R 60-1, 5.6.3 and R 60-3, 2.1.7"
2821
+ },
2822
+ {
2823
+ "address": "clause-6.10.1.1/s6",
2824
+ "fragment": "clause-6.10.1.1",
2825
+ "clause": "6.10.1.1",
2826
+ "kind": "provision",
2827
+ "fragment_normative": true,
2828
+ "modality": "informative",
2829
+ "text": "Change (*), C_{\"Hmax\"}: PASS: ☐ FAIL: ☐"
2830
+ },
2831
+ {
2832
+ "address": "clause-6.10.1.1/note-1/s1",
2833
+ "fragment": "clause-6.10.1.1/note-1",
2834
+ "kind": "note",
2835
+ "fragment_normative": false,
2836
+ "modality": "informative",
2837
+ "text": "This test is not necessary if the load cell is marked NH or SH."
2838
+ },
2839
+ {
2840
+ "address": "clause-6.10.1.1/note-1/s2",
2841
+ "fragment": "clause-6.10.1.1/note-1",
2842
+ "kind": "note",
2843
+ "fragment_normative": false,
2844
+ "modality": "informative",
2845
+ "text": "Change (v): the difference between the indication after and before humidity exposure divided by the conversion factor, f."
2846
+ },
2847
+ {
2848
+ "address": "clause-6.10.1.1/note-1/s3",
2849
+ "fragment": "clause-6.10.1.1/note-1",
2850
+ "kind": "note",
2851
+ "fragment_normative": false,
2852
+ "modality": "informative",
2853
+ "text": "Use five test runs for Class A and B; use 3 test runs for Class C and D."
2854
+ },
2855
+ {
2856
+ "address": "clause-6.10.1.1/note-1/s4",
2857
+ "fragment": "clause-6.10.1.1/note-1",
2858
+ "kind": "note",
2859
+ "fragment_normative": false,
2860
+ "modality": "informative",
2861
+ "text": "Absolute (not relative) time shall be recorded."
2862
+ },
2863
+ {
2864
+ "address": "clause-6.10.1.1/note-1/s5",
2865
+ "fragment": "clause-6.10.1.1/note-1",
2866
+ "kind": "note",
2867
+ "fragment_normative": false,
2868
+ "modality": "informative",
2869
+ "text": "For family certification this test is not necessary, if a pattern with a smaller capacity and the same or better metrological characteristics has passed this test."
2870
+ },
2871
+ {
2872
+ "address": "clause-6.10.2/s1",
2873
+ "fragment": "clause-6.10.2",
2874
+ "clause": "6.10.2",
2875
+ "kind": "provision",
2876
+ "fragment_normative": true,
2877
+ "modality": "informative",
2878
+ "text": "R 60-2, 2.10.1.1-2.10.1.11."
2879
+ },
2880
+ {
2881
+ "address": "clause-6.10.2/s2",
2882
+ "fragment": "clause-6.10.2",
2883
+ "clause": "6.10.2",
2884
+ "kind": "provision",
2885
+ "fragment_normative": true,
2886
+ "modality": "informative",
2887
+ "text": "Complete this form if the measurement error is determined before the humidity test (CH) is carried out (not mandatory)"
2888
+ },
2889
+ {
2890
+ "address": "clause-6.10.2/s3",
2891
+ "fragment": "clause-6.10.2",
2892
+ "clause": "6.10.2",
2893
+ "kind": "provision",
2894
+ "fragment_normative": true,
2895
+ "modality": "informative",
2896
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: E_{\"min\"}: n_{\"LC\"}: p_{\"LC\"}: Y: Z: v_{\"min\"}: DR: Force-generating system: Test load:, D_{\"max\"}: D_{\"min\"}: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Electronics power voltage (when applicable):"
2897
+ },
2898
+ {
2899
+ "address": "table-9/note-1/s1",
2900
+ "fragment": "table-9/note-1",
2901
+ "kind": "note",
2902
+ "fragment_normative": false,
2903
+ "modality": "informative",
2904
+ "text": "* Average initial minimum test load indication"
2905
+ },
2906
+ {
2907
+ "address": "table-9/note-1/s2",
2908
+ "fragment": "table-9/note-1",
2909
+ "kind": "note",
2910
+ "fragment_normative": false,
2911
+ "modality": "informative",
2912
+ "text": "Absolute (not relative) time shall be recorded"
2913
+ },
2914
+ {
2915
+ "address": "clause-6.10.2.1/s1",
2916
+ "fragment": "clause-6.10.2.1",
2917
+ "clause": "6.10.2.1",
2918
+ "kind": "provision",
2919
+ "fragment_normative": true,
2920
+ "modality": "informative",
2921
+ "text": "R 60-2, 2.10.1.1-2.10.1.11."
2922
+ },
2923
+ {
2924
+ "address": "clause-6.10.2.1/s2",
2925
+ "fragment": "clause-6.10.2.1",
2926
+ "clause": "6.10.2.1",
2927
+ "kind": "provision",
2928
+ "fragment_normative": true,
2929
+ "modality": "informative",
2930
+ "text": "Complete this form if the measurement error is determined after the humidity test (CH) is carried out (not mandatory)"
2931
+ },
2932
+ {
2933
+ "address": "clause-6.10.2.1/s3",
2934
+ "fragment": "clause-6.10.2.1",
2935
+ "clause": "6.10.2.1",
2936
+ "kind": "provision",
2937
+ "fragment_normative": true,
2938
+ "modality": "informative",
2939
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: E_{\"min\"}: n_{\"LC\"}: p_{\"LC\"}: Y: Z: v_{\"min\"}: DR: Force-generating system: Test load:, D_{\"max\"}: D_{\"min\"}: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Electronics power voltage (when applicable):"
2940
+ },
2941
+ {
2942
+ "address": "table-10/note-1/s1",
2943
+ "fragment": "table-10/note-1",
2944
+ "kind": "note",
2945
+ "fragment_normative": false,
2946
+ "modality": "informative",
2947
+ "text": "* Average initial minimum test load indication"
2948
+ },
2949
+ {
2950
+ "address": "table-10/note-1/s2",
2951
+ "fragment": "table-10/note-1",
2952
+ "kind": "note",
2953
+ "fragment_normative": false,
2954
+ "modality": "informative",
2955
+ "text": "Absolute (not relative) time shall be recorded"
2956
+ },
2957
+ {
2958
+ "address": "clause-6.10.3/s1",
2959
+ "fragment": "clause-6.10.3",
2960
+ "clause": "6.10.3",
2961
+ "kind": "provision",
2962
+ "fragment_normative": true,
2963
+ "modality": "informative",
2964
+ "text": "R 60-2, 2.10.1.1-2.10.1.11."
2965
+ },
2966
+ {
2967
+ "address": "clause-6.10.3/s2",
2968
+ "fragment": "clause-6.10.3",
2969
+ "clause": "6.10.3",
2970
+ "kind": "provision",
2971
+ "fragment_normative": true,
2972
+ "modality": "informative",
2973
+ "text": "Complete this form if the measurement error is determined before the humidity test (CH) is carried out (not mandatory)"
2974
+ },
2975
+ {
2976
+ "address": "clause-6.10.3/s3",
2977
+ "fragment": "clause-6.10.3",
2978
+ "clause": "6.10.3",
2979
+ "kind": "provision",
2980
+ "fragment_normative": true,
2981
+ "modality": "informative",
2982
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Electronics power voltage (when applicable):"
2983
+ },
2984
+ {
2985
+ "address": "table-11/note-1/s1",
2986
+ "fragment": "table-11/note-1",
2987
+ "kind": "note",
2988
+ "fragment_normative": false,
2989
+ "modality": "informative",
2990
+ "text": "* Average initial minimum test load indication"
2991
+ },
2992
+ {
2993
+ "address": "clause-6.10.4/s1",
2994
+ "fragment": "clause-6.10.4",
2995
+ "clause": "6.10.4",
2996
+ "kind": "provision",
2997
+ "fragment_normative": true,
2998
+ "modality": "informative",
2999
+ "text": "R 60-2, 2.10.1.1-2.10.1.11."
3000
+ },
3001
+ {
3002
+ "address": "clause-6.10.4/s2",
3003
+ "fragment": "clause-6.10.4",
3004
+ "clause": "6.10.4",
3005
+ "kind": "provision",
3006
+ "fragment_normative": true,
3007
+ "modality": "informative",
3008
+ "text": "Complete this form if the measurement error is determined after the humidity test (CH) is carried out (not mandatory)"
3009
+ },
3010
+ {
3011
+ "address": "clause-6.10.4/s3",
3012
+ "fragment": "clause-6.10.4",
3013
+ "clause": "6.10.4",
3014
+ "kind": "provision",
3015
+ "fragment_normative": true,
3016
+ "modality": "informative",
3017
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: E_{\"min\"}: n_{\"LC\"}: p_{\"LC\"}: Y: Z: v_{\"min\"}: DR: Force-generating system: Test load:, D_{\"max\"}: D_{\"min\"}: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Electronics power voltage (when applicable):"
3018
+ },
3019
+ {
3020
+ "address": "table-12/note-1/s1",
3021
+ "fragment": "table-12/note-1",
3022
+ "kind": "note",
3023
+ "fragment_normative": false,
3024
+ "modality": "informative",
3025
+ "text": "* Average initial minimum test load indication"
3026
+ },
3027
+ {
3028
+ "address": "clause-6.10.5.1/s1",
3029
+ "fragment": "clause-6.10.5.1",
3030
+ "clause": "6.10.5.1",
3031
+ "kind": "provision",
3032
+ "fragment_normative": true,
3033
+ "modality": "informative",
3034
+ "text": "R 60-1, 5.6.3.2 R 60-2, 2.7.3.9, 2.10.6 R 60-3, 2.1.8"
3035
+ },
3036
+ {
3037
+ "address": "clause-6.10.5.1/s2",
3038
+ "fragment": "clause-6.10.5.1",
3039
+ "clause": "6.10.5.1",
3040
+ "kind": "provision",
3041
+ "fragment_normative": true,
3042
+ "modality": "informative",
3043
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: At start At end Date: Conditioning period: Reference temperature: \"unitsml(degC)\" High temperature: \"unitsml(degC)\" Reference relative humidity: % High relative humidity: % Conversion factor, f: Page of load test before humidity test: Page of load test during humidity test: Page of load test after humidity test:"
3044
+ },
3045
+ {
3046
+ "address": "clause-6.10.5.1/s3",
3047
+ "fragment": "clause-6.10.5.1",
3048
+ "clause": "6.10.5.1",
3049
+ "kind": "provision",
3050
+ "fragment_normative": true,
3051
+ "modality": "informative",
3052
+ "text": "For summary of SH-humidity load test errors: use form 6.3 (3 runs) or 6.4 (5 runs) as appropriate to record individual teat results."
3053
+ },
3054
+ {
3055
+ "address": "clause-6.10.5.1/s4",
3056
+ "fragment": "clause-6.10.5.1",
3057
+ "clause": "6.10.5.1",
3058
+ "kind": "provision",
3059
+ "fragment_normative": true,
3060
+ "modality": "informative",
3061
+ "text": "PASS: FAIL:"
3062
+ },
3063
+ {
3064
+ "address": "clause-6.10.5.1/note-1/s1",
3065
+ "fragment": "clause-6.10.5.1/note-1",
3066
+ "kind": "note",
3067
+ "fragment_normative": false,
3068
+ "modality": "informative",
3069
+ "text": "Load/reference indications: if at 75 % load point was not obtained, a straight line interpolation between the adjacent higher and lower load point indication is used."
3070
+ },
3071
+ {
3072
+ "address": "clause-6.10.5.1/note-1/s2",
3073
+ "fragment": "clause-6.10.5.1/note-1",
3074
+ "kind": "note",
3075
+ "fragment_normative": false,
3076
+ "modality": "informative",
3077
+ "text": "Error, E_{\"L\"}: the difference between the test reference and the reference indication divided by the conversion factor, f."
3078
+ },
3079
+ {
3080
+ "address": "clause-6.10.5.1/note-1/s3",
3081
+ "fragment": "clause-6.10.5.1/note-1",
3082
+ "kind": "note",
3083
+ "fragment_normative": false,
3084
+ "modality": "informative",
3085
+ "text": "Test load values are values above minimum test load, D_{\"min\"}."
3086
+ },
3087
+ {
3088
+ "address": "clause-6.10.5.1/note-1/s4",
3089
+ "fragment": "clause-6.10.5.1/note-1",
3090
+ "kind": "note",
3091
+ "fragment_normative": false,
3092
+ "modality": "informative",
3093
+ "text": "Conditioning period: the time period for exercising the load cell."
3094
+ },
3095
+ {
3096
+ "address": "clause-6.10.5.1/note-1/s5",
3097
+ "fragment": "clause-6.10.5.1/note-1",
3098
+ "kind": "note",
3099
+ "fragment_normative": false,
3100
+ "modality": "informative",
3101
+ "text": "For family certification this test is not necessary, if a pattern with a smaller capacity and the same or better metrological characteristics has passed this test."
3102
+ },
3103
+ {
3104
+ "address": "clause-6.11.1/s1",
3105
+ "fragment": "clause-6.11.1",
3106
+ "clause": "6.11.1",
3107
+ "kind": "provision",
3108
+ "fragment_normative": true,
3109
+ "modality": "informative",
3110
+ "text": "R 60-1, 3.5.17 R 60-2, 2.10.7.3 R 60-3, 2.2.1"
3111
+ },
3112
+ {
3113
+ "address": "clause-6.11.1/s2",
3114
+ "fragment": "clause-6.11.1",
3115
+ "clause": "6.11.1",
3116
+ "kind": "provision",
3117
+ "fragment_normative": true,
3118
+ "modality": "informative",
3119
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: E_{\"min\"}: n_{\"LC\"}: p_{\"LC\"}: Y: Z: v_{\"min\"}: DR: Force-generating system: Test load:, D_{\"max\"}: D_{\"min\"}: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Conversion factor, f: counts/v Duration of disconnection before test:"
3120
+ },
3121
+ {
3122
+ "address": "clause-6.11.1/s3",
3123
+ "fragment": "clause-6.11.1",
3124
+ "clause": "6.11.1",
3125
+ "kind": "provision",
3126
+ "fragment_normative": true,
3127
+ "modality": "informative",
3128
+ "text": "PASS: ☐ FAIL: ☐"
3129
+ },
3130
+ {
3131
+ "address": "clause-6.11.1/note-1/s1",
3132
+ "fragment": "clause-6.11.1/note-1",
3133
+ "kind": "note",
3134
+ "fragment_normative": false,
3135
+ "modality": "informative",
3136
+ "text": "Absolute (not relative) time shall be recorded."
3137
+ },
3138
+ {
3139
+ "address": "clause-6.11.1/note-1/s2",
3140
+ "fragment": "clause-6.11.1/note-1",
3141
+ "kind": "note",
3142
+ "fragment_normative": false,
3143
+ "modality": "informative",
3144
+ "text": "Span: the result of subtraction of the indication at minimum test load from the indication at maximum test load."
3145
+ },
3146
+ {
3147
+ "address": "clause-6.11.1/note-1/s3",
3148
+ "fragment": "clause-6.11.1/note-1",
3149
+ "kind": "note",
3150
+ "fragment_normative": false,
3151
+ "modality": "informative",
3152
+ "text": "All span errors (error at maximum test load minus the error at minimum test load) shall be within the maximum permissible error during the 30 minute test."
3153
+ },
3154
+ {
3155
+ "address": "clause-6.11.1/note-1/s4",
3156
+ "fragment": "clause-6.11.1/note-1",
3157
+ "kind": "note",
3158
+ "fragment_normative": false,
3159
+ "modality": "informative",
3160
+ "text": "The change of span must not exceed v_{\"min\"}."
3161
+ },
3162
+ {
3163
+ "address": "clause-6.11.1/note-1/s5",
3164
+ "fragment": "clause-6.11.1/note-1",
3165
+ "kind": "note",
3166
+ "fragment_normative": false,
3167
+ "modality": "informative",
3168
+ "text": "Change: the difference between the span and the initial run span."
3169
+ },
3170
+ {
3171
+ "address": "clause-6.11.1/note-1/s6",
3172
+ "fragment": "clause-6.11.1/note-1",
3173
+ "kind": "note",
3174
+ "fragment_normative": false,
3175
+ "modality": "informative",
3176
+ "text": "Maximum permissible change, mpc: the absolute value of the maximum permissible error for the maximum test load applied."
3177
+ },
3178
+ {
3179
+ "address": "clause-6.11.1/note-1/s7",
3180
+ "fragment": "clause-6.11.1/note-1",
3181
+ "kind": "note",
3182
+ "fragment_normative": false,
3183
+ "modality": "informative",
3184
+ "text": "Exercises have to be run before disconnection."
3185
+ },
3186
+ {
3187
+ "address": "clause-6.12.1/s1",
3188
+ "fragment": "clause-6.12.1",
3189
+ "clause": "6.12.1",
3190
+ "kind": "provision",
3191
+ "fragment_normative": true,
3192
+ "modality": "informative",
3193
+ "text": "R 60-1, 5.7.2.2, 5.7.2.3, 5.7.2.4 R 60-2, 2.10.7.4 R 60-3, 2.2.2"
3194
+ },
3195
+ {
3196
+ "address": "clause-6.12.1/s2",
3197
+ "fragment": "clause-6.12.1",
3198
+ "clause": "6.12.1",
3199
+ "kind": "provision",
3200
+ "fragment_normative": true,
3201
+ "modality": "informative",
3202
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: E_{\"min\"}: n_{\"LC\"}: p_{\"LC\"}: Y: Z: v_{\"min\"}: DR: Force-generating system: Test load:, D_{\"max\"}: D_{\"min\"}: Indicating instrument: Evaluator: At start At end Date: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Indicator temperature: \"unitsml(degC)\" Conversion factor, f: counts/v Main voltage: AC: DC:"
3203
+ },
3204
+ {
3205
+ "address": "clause-6.12.1/s3",
3206
+ "fragment": "clause-6.12.1",
3207
+ "clause": "6.12.1",
3208
+ "kind": "provision",
3209
+ "fragment_normative": true,
3210
+ "modality": "informative",
3211
+ "text": "PASS: ☐ FAIL:☐"
3212
+ },
3213
+ {
3214
+ "address": "table-15/note-1/s1",
3215
+ "fragment": "table-15/note-1",
3216
+ "kind": "note",
3217
+ "fragment_normative": false,
3218
+ "modality": "informative",
3219
+ "text": "Reference indications: if at 75 % load point was not obtained, a straight line interpolation between the adjacent higher and lower indication is used (see 2.8.2 in R 60-2 and calculation procedures in R 60-3, 2.1.2)"
3220
+ },
3221
+ {
3222
+ "address": "table-15/note-1/s2",
3223
+ "fragment": "table-15/note-1",
3224
+ "kind": "note",
3225
+ "fragment_normative": false,
3226
+ "modality": "informative",
3227
+ "text": "Error: the difference between the test indication and the reference indication divided by the conversion factor, f."
3228
+ },
3229
+ {
3230
+ "address": "table-15/note-1/s3",
3231
+ "fragment": "table-15/note-1",
3232
+ "kind": "note",
3233
+ "fragment_normative": false,
3234
+ "modality": "informative",
3235
+ "text": "The change of span must not exceed v_{\"min\"}."
3236
+ },
3237
+ {
3238
+ "address": "table-15/note-1/s4",
3239
+ "fragment": "table-15/note-1",
3240
+ "kind": "note",
3241
+ "fragment_normative": false,
3242
+ "modality": "informative",
3243
+ "text": "When a voltage range is marked, use the average value as the reference value and determine upper and lower values of applied voltage according to R 60-2, 2.10.7.4."
3244
+ },
3245
+ {
3246
+ "address": "table-15/note-1/s5",
3247
+ "fragment": "table-15/note-1",
3248
+ "kind": "note",
3249
+ "fragment_normative": false,
3250
+ "modality": "informative",
3251
+ "text": "Upper limit not applicable to battery powered load cells"
3252
+ },
3253
+ {
3254
+ "address": "table-15/note-1/s6",
3255
+ "fragment": "table-15/note-1",
3256
+ "kind": "note",
3257
+ "fragment_normative": false,
3258
+ "modality": "informative",
3259
+ "text": "At lower limit, battery powered load cells shall function and be within MPE, or cease to function"
3260
+ },
3261
+ {
3262
+ "address": "clause-6.13.1/s1",
3263
+ "fragment": "clause-6.13.1",
3264
+ "clause": "6.13.1",
3265
+ "kind": "provision",
3266
+ "fragment_normative": true,
3267
+ "modality": "informative",
3268
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.5 R 60-3, 2.2.3"
3269
+ },
3270
+ {
3271
+ "address": "clause-6.13.1/s2",
3272
+ "fragment": "clause-6.13.1",
3273
+ "clause": "6.13.1",
3274
+ "kind": "provision",
3275
+ "fragment_normative": true,
3276
+ "modality": "informative",
3277
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Conversion factor, f: Minimum test load, D_{\"min\"}: Reference voltage range: V"
3278
+ },
3279
+ {
3280
+ "address": "clause-6.13.1/s3",
3281
+ "fragment": "clause-6.13.1",
3282
+ "clause": "6.13.1",
3283
+ "kind": "provision",
3284
+ "fragment_normative": true,
3285
+ "modality": "informative",
3286
+ "text": "PASS: ☐ FAIL: ☐"
3287
+ },
3288
+ {
3289
+ "address": "clause-6.13.1/s4",
3290
+ "fragment": "clause-6.13.1",
3291
+ "clause": "6.13.1",
3292
+ "kind": "provision",
3293
+ "fragment_normative": true,
3294
+ "modality": "informative",
3295
+ "text": "Equipment used (supply sketch if necessary):"
3296
+ },
3297
+ {
3298
+ "address": "clause-6.13.1/s5",
3299
+ "fragment": "clause-6.13.1",
3300
+ "clause": "6.13.1",
3301
+ "kind": "provision",
3302
+ "fragment_normative": true,
3303
+ "modality": "informative",
3304
+ "text": "Remarks:"
3305
+ },
3306
+ {
3307
+ "address": "clause-6.13.1/note-1/s1",
3308
+ "fragment": "clause-6.13.1/note-1",
3309
+ "kind": "note",
3310
+ "fragment_normative": false,
3311
+ "modality": "informative",
3312
+ "text": "In the case of a voltage range, use the average value as the reference value."
3313
+ },
3314
+ {
3315
+ "address": "clause-6.14.1/s1",
3316
+ "fragment": "clause-6.14.1",
3317
+ "clause": "6.14.1",
3318
+ "kind": "provision",
3319
+ "fragment_normative": true,
3320
+ "modality": "informative",
3321
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.6 R 60-3, 2.2.4"
3322
+ },
3323
+ {
3324
+ "address": "clause-6.14.1/s2",
3325
+ "fragment": "clause-6.14.1",
3326
+ "clause": "6.14.1",
3327
+ "kind": "provision",
3328
+ "fragment_normative": true,
3329
+ "modality": "informative",
3330
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Conversion factor, f: Minimum test load, D_{\"min\"}:"
3331
+ },
3332
+ {
3333
+ "address": "clause-6.14.1/s3",
3334
+ "fragment": "clause-6.14.1",
3335
+ "clause": "6.14.1",
3336
+ "kind": "provision",
3337
+ "fragment_normative": true,
3338
+ "modality": "informative",
3339
+ "text": "PASS: ☐ FAIL: ☐"
3340
+ },
3341
+ {
3342
+ "address": "clause-6.14.1/s4",
3343
+ "fragment": "clause-6.14.1",
3344
+ "clause": "6.14.1",
3345
+ "kind": "provision",
3346
+ "fragment_normative": true,
3347
+ "modality": "informative",
3348
+ "text": "L = phase, N = neutral, PE = protective earth"
3349
+ },
3350
+ {
3351
+ "address": "clause-6.14.1/s5",
3352
+ "fragment": "clause-6.14.1",
3353
+ "clause": "6.14.1",
3354
+ "kind": "provision",
3355
+ "fragment_normative": true,
3356
+ "modality": "informative",
3357
+ "text": "Equipment used (supply sketch if necessary)"
3358
+ },
3359
+ {
3360
+ "address": "clause-6.14.2/s1",
3361
+ "fragment": "clause-6.14.2",
3362
+ "clause": "6.14.2",
3363
+ "kind": "provision",
3364
+ "fragment_normative": true,
3365
+ "modality": "informative",
3366
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.6 R 60-3, 2.2.4"
3367
+ },
3368
+ {
3369
+ "address": "clause-6.14.2/s2",
3370
+ "fragment": "clause-6.14.2",
3371
+ "clause": "6.14.2",
3372
+ "kind": "provision",
3373
+ "fragment_normative": true,
3374
+ "modality": "informative",
3375
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Conversion factor, f: Minimum test load, D_{\"min\"}:"
3376
+ },
3377
+ {
3378
+ "address": "clause-6.14.2/s3",
3379
+ "fragment": "clause-6.14.2",
3380
+ "clause": "6.14.2",
3381
+ "kind": "provision",
3382
+ "fragment_normative": true,
3383
+ "modality": "informative",
3384
+ "text": "PASS: ☐ FAIL: ☐"
3385
+ },
3386
+ {
3387
+ "address": "clause-6.14.2/s4",
3388
+ "fragment": "clause-6.14.2",
3389
+ "clause": "6.14.2",
3390
+ "kind": "provision",
3391
+ "fragment_normative": true,
3392
+ "modality": "informative",
3393
+ "text": "Equipment used (supply sketch if necessary)"
3394
+ },
3395
+ {
3396
+ "address": "clause-6.14.2/s5",
3397
+ "fragment": "clause-6.14.2",
3398
+ "clause": "6.14.2",
3399
+ "kind": "provision",
3400
+ "fragment_normative": true,
3401
+ "modality": "informative",
3402
+ "text": "Remarks:"
3403
+ },
3404
+ {
3405
+ "address": "clause-6.14.2/note-1/s1",
3406
+ "fragment": "clause-6.14.2/note-1",
3407
+ "kind": "note",
3408
+ "fragment_normative": false,
3409
+ "modality": "informative",
3410
+ "text": "Explain or make a sketch indicating where the clamp is located on the cable: if necessary use additional page(s)."
3411
+ },
3412
+ {
3413
+ "address": "clause-6.15.1/s1",
3414
+ "fragment": "clause-6.15.1",
3415
+ "clause": "6.15.1",
3416
+ "kind": "provision",
3417
+ "fragment_normative": true,
3418
+ "modality": "informative",
3419
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.7 R 60-3, 2.2.5"
3420
+ },
3421
+ {
3422
+ "address": "clause-6.15.1/s2",
3423
+ "fragment": "clause-6.15.1",
3424
+ "clause": "6.15.1",
3425
+ "kind": "provision",
3426
+ "fragment_normative": true,
3427
+ "modality": "informative",
3428
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Conversion factor, f: Minimum test load, D_{\"min\"}:"
3429
+ },
3430
+ {
3431
+ "address": "clause-6.16.1/s1",
3432
+ "fragment": "clause-6.16.1",
3433
+ "clause": "6.16.1",
3434
+ "kind": "provision",
3435
+ "fragment_normative": true,
3436
+ "modality": "informative",
3437
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.8 R 60-3, 2.2.6"
3438
+ },
3439
+ {
3440
+ "address": "clause-6.16.1/s2",
3441
+ "fragment": "clause-6.16.1",
3442
+ "clause": "6.16.1",
3443
+ "kind": "provision",
3444
+ "fragment_normative": true,
3445
+ "modality": "informative",
3446
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Conversion factor, f: Minimum test load, D_{\"min\"}: Contact discharges Paint penetration Air discharges Polarity (see note-6.16-2): Positive Negative"
3447
+ },
3448
+ {
3449
+ "address": "clause-6.16.1/s3",
3450
+ "fragment": "clause-6.16.1",
3451
+ "clause": "6.16.1",
3452
+ "kind": "provision",
3453
+ "fragment_normative": true,
3454
+ "modality": "informative",
3455
+ "text": "PASS: ☐ FAIL: ☐"
3456
+ },
3457
+ {
3458
+ "address": "clause-6.16.1/s4",
3459
+ "fragment": "clause-6.16.1",
3460
+ "clause": "6.16.1",
3461
+ "kind": "provision",
3462
+ "fragment_normative": true,
3463
+ "modality": "informative",
3464
+ "text": "Remarks:"
3465
+ },
3466
+ {
3467
+ "address": "clause-6.16.1/note-1/s1",
3468
+ "fragment": "clause-6.16.1/note-1",
3469
+ "kind": "note",
3470
+ "fragment_normative": false,
3471
+ "modality": "informative",
3472
+ "text": "If the load cell fails, the test point at which this occurs shall be recorded."
3473
+ },
3474
+ {
3475
+ "address": "clause-6.16.1/note-2/s1",
3476
+ "fragment": "clause-6.16.1/note-2",
3477
+ "kind": "note",
3478
+ "fragment_normative": false,
3479
+ "modality": "informative",
3480
+ "text": "IEC Publication 61000-4-2 Ed 2.0 (2008-12) Consolidated edition specifies that the test be conducted with the most sensitive polarity."
3481
+ },
3482
+ {
3483
+ "address": "clause-6.16.2/s1",
3484
+ "fragment": "clause-6.16.2",
3485
+ "clause": "6.16.2",
3486
+ "kind": "provision",
3487
+ "fragment_normative": true,
3488
+ "modality": "informative",
3489
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.8 R 60-3, 2.2.6"
3490
+ },
3491
+ {
3492
+ "address": "clause-6.16.2/s2",
3493
+ "fragment": "clause-6.16.2",
3494
+ "clause": "6.16.2",
3495
+ "kind": "provision",
3496
+ "fragment_normative": true,
3497
+ "modality": "informative",
3498
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Conversion factor, f: Minimum test load, D_{\"min\"}: Polarity (see note-6.16.2-2): Positive Negative"
3499
+ },
3500
+ {
3501
+ "address": "clause-6.16.2/s3",
3502
+ "fragment": "clause-6.16.2",
3503
+ "clause": "6.16.2",
3504
+ "kind": "provision",
3505
+ "fragment_normative": true,
3506
+ "modality": "informative",
3507
+ "text": "PASS: ☐ FAIL: ☐"
3508
+ },
3509
+ {
3510
+ "address": "clause-6.16.2/s4",
3511
+ "fragment": "clause-6.16.2",
3512
+ "clause": "6.16.2",
3513
+ "kind": "provision",
3514
+ "fragment_normative": true,
3515
+ "modality": "informative",
3516
+ "text": "Remarks:"
3517
+ },
3518
+ {
3519
+ "address": "clause-6.16.2/note-1/s1",
3520
+ "fragment": "clause-6.16.2/note-1",
3521
+ "kind": "note",
3522
+ "fragment_normative": false,
3523
+ "modality": "informative",
3524
+ "text": "If the load cell fails, the test point at which this occurs shall be recorded."
3525
+ },
3526
+ {
3527
+ "address": "clause-6.16.2/note-2/s1",
3528
+ "fragment": "clause-6.16.2/note-2",
3529
+ "kind": "note",
3530
+ "fragment_normative": false,
3531
+ "modality": "informative",
3532
+ "text": "IEC Publication 61000-4-2 Ed."
3533
+ },
3534
+ {
3535
+ "address": "clause-6.16.2/note-2/s2",
3536
+ "fragment": "clause-6.16.2/note-2",
3537
+ "kind": "note",
3538
+ "fragment_normative": false,
3539
+ "modality": "informative",
3540
+ "text": "2.0 (2008-12)."
3541
+ },
3542
+ {
3543
+ "address": "clause-6.16.2/note-2/s3",
3544
+ "fragment": "clause-6.16.2/note-2",
3545
+ "kind": "note",
3546
+ "fragment_normative": false,
3547
+ "modality": "informative",
3548
+ "text": "Consolidated edition specifies that the test be conducted with the most sensitive polarity."
3549
+ },
3550
+ {
3551
+ "address": "clause-6.16.3/s1",
3552
+ "fragment": "clause-6.16.3",
3553
+ "clause": "6.16.3",
3554
+ "kind": "provision",
3555
+ "fragment_normative": true,
3556
+ "modality": "informative",
3557
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.8 R 60-3, 2.2.6"
3558
+ },
3559
+ {
3560
+ "address": "clause-6.16.3/s2",
3561
+ "fragment": "clause-6.16.3",
3562
+ "clause": "6.16.3",
3563
+ "kind": "provision",
3564
+ "fragment_normative": true,
3565
+ "modality": "informative",
3566
+ "text": "Specify test points utilised on load cell and test equipment used, e.g. by photos or sketches."
3567
+ },
3568
+ {
3569
+ "address": "clause-6.16.3/s3",
3570
+ "fragment": "clause-6.16.3",
3571
+ "clause": "6.16.3",
3572
+ "kind": "provision",
3573
+ "fragment_normative": true,
3574
+ "modality": "informative",
3575
+ "text": "Direct application Contact discharges: Air discharges:"
3576
+ },
3577
+ {
3578
+ "address": "clause-6.16.3/s4",
3579
+ "fragment": "clause-6.16.3",
3580
+ "clause": "6.16.3",
3581
+ "kind": "provision",
3582
+ "fragment_normative": true,
3583
+ "modality": "informative",
3584
+ "text": "Indirect application"
3585
+ },
3586
+ {
3587
+ "address": "clause-6.17.1/s1",
3588
+ "fragment": "clause-6.17.1",
3589
+ "clause": "6.17.1",
3590
+ "kind": "provision",
3591
+ "fragment_normative": true,
3592
+ "modality": "informative",
3593
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.9 R 60-3, 2.2.7"
3594
+ },
3595
+ {
3596
+ "address": "clause-6.17.1/s2",
3597
+ "fragment": "clause-6.17.1",
3598
+ "clause": "6.17.1",
3599
+ "kind": "provision",
3600
+ "fragment_normative": true,
3601
+ "modality": "informative",
3602
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Conversion factor, f: Minimum test load, D_{\"min\"}: Rate of sweep: Test load: Test load material:"
3603
+ },
3604
+ {
3605
+ "address": "clause-6.17.1/s3",
3606
+ "fragment": "clause-6.17.1",
3607
+ "clause": "6.17.1",
3608
+ "kind": "provision",
3609
+ "fragment_normative": true,
3610
+ "modality": "informative",
3611
+ "text": "PASS: ☐ FAIL: ☐"
3612
+ },
3613
+ {
3614
+ "address": "clause-6.17.1/s4",
3615
+ "fragment": "clause-6.17.1",
3616
+ "clause": "6.17.1",
3617
+ "kind": "provision",
3618
+ "fragment_normative": true,
3619
+ "modality": "informative",
3620
+ "text": "Frequency range: 80 \"unitsml(MHz)\"The lower limit of frequency of electromagnetic field is 26 MHz for load cells without power lines or I/O ports, and for which the test for conducted electromagnetic field (R 60-2, 2.10.7.10) is not applicable. to 3000 \"unitsml(MHz)\""
3621
+ },
3622
+ {
3623
+ "address": "clause-6.17.1/s5",
3624
+ "fragment": "clause-6.17.1",
3625
+ "clause": "6.17.1",
3626
+ "kind": "provision",
3627
+ "fragment_normative": true,
3628
+ "modality": "informative",
3629
+ "text": "Field strength: 10 \"unitsml(V/m)\""
3630
+ },
3631
+ {
3632
+ "address": "clause-6.17.1/s6",
3633
+ "fragment": "clause-6.17.1",
3634
+ "clause": "6.17.1",
3635
+ "kind": "provision",
3636
+ "fragment_normative": true,
3637
+ "modality": "informative",
3638
+ "text": "Modulation: 80 % AM, 1 \"unitsml(kHz)\" sine wave"
3639
+ },
3640
+ {
3641
+ "address": "clause-6.17.1/s7",
3642
+ "fragment": "clause-6.17.1",
3643
+ "clause": "6.17.1",
3644
+ "kind": "provision",
3645
+ "fragment_normative": true,
3646
+ "modality": "informative",
3647
+ "text": "Remarks:"
3648
+ },
3649
+ {
3650
+ "address": "clause-6.17.1/note-1/s1",
3651
+ "fragment": "clause-6.17.1/note-1",
3652
+ "kind": "note",
3653
+ "fragment_normative": false,
3654
+ "modality": "informative",
3655
+ "text": "If the load cell fails, the test point at which this occurs shall be recorded."
3656
+ },
3657
+ {
3658
+ "address": "clause-6.17.2/s1",
3659
+ "fragment": "clause-6.17.2",
3660
+ "clause": "6.17.2",
3661
+ "kind": "provision",
3662
+ "fragment_normative": true,
3663
+ "modality": "informative",
3664
+ "text": "Describe the setup of the test and equipment, e.g. by photos or sketches:"
3665
+ },
3666
+ {
3667
+ "address": "clause-6.18.1/s1",
3668
+ "fragment": "clause-6.18.1",
3669
+ "clause": "6.18.1",
3670
+ "kind": "provision",
3671
+ "fragment_normative": true,
3672
+ "modality": "informative",
3673
+ "text": "R 60-1, 5.7.2.5 R 60-2, 2.10.7.10 R 60-3, 2.2.8"
3674
+ },
3675
+ {
3676
+ "address": "clause-6.18.1/s2",
3677
+ "fragment": "clause-6.18.1",
3678
+ "clause": "6.18.1",
3679
+ "kind": "provision",
3680
+ "fragment_normative": true,
3681
+ "modality": "informative",
3682
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\" Conversion factor, f: Minimum test load, D_{\"min\"}: Rate of sweep: Test load: Test load material:"
3683
+ },
3684
+ {
3685
+ "address": "clause-6.19.1/s1",
3686
+ "fragment": "clause-6.19.1",
3687
+ "clause": "6.19.1",
3688
+ "kind": "provision",
3689
+ "fragment_normative": true,
3690
+ "modality": "informative",
3691
+ "text": "R 60-1, 5.7.2.6 R 60-2, 2.10.7.11 R 60-3, 2.2.9"
3692
+ },
3693
+ {
3694
+ "address": "clause-6.19.1/s2",
3695
+ "fragment": "clause-6.19.1",
3696
+ "clause": "6.19.1",
3697
+ "kind": "provision",
3698
+ "fragment_normative": true,
3699
+ "modality": "informative",
3700
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator: Conversion factor, f: Minimum test load, D_{\"min\"}: Maximum test load, D_{\"max\"}:"
3701
+ },
3702
+ {
3703
+ "address": "clause-6.19.1/s3",
3704
+ "fragment": "clause-6.19.1",
3705
+ "clause": "6.19.1",
3706
+ "kind": "provision",
3707
+ "fragment_normative": true,
3708
+ "modality": "informative",
3709
+ "text": "Measurement no."
3710
+ },
3711
+ {
3712
+ "address": "clause-6.19.1/s4",
3713
+ "fragment": "clause-6.19.1",
3714
+ "clause": "6.19.1",
3715
+ "kind": "provision",
3716
+ "fragment_normative": true,
3717
+ "modality": "informative",
3718
+ "text": "1:"
3719
+ },
3720
+ {
3721
+ "address": "clause-6.19.1/s5",
3722
+ "fragment": "clause-6.19.1",
3723
+ "clause": "6.19.1",
3724
+ "kind": "provision",
3725
+ "fragment_normative": true,
3726
+ "modality": "informative",
3727
+ "text": "Evaluator: ____________________ Remarks:"
3728
+ },
3729
+ {
3730
+ "address": "clause-6.19.1/s6",
3731
+ "fragment": "clause-6.19.1",
3732
+ "clause": "6.19.1",
3733
+ "kind": "provision",
3734
+ "fragment_normative": true,
3735
+ "modality": "informative",
3736
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3737
+ },
3738
+ {
3739
+ "address": "clause-6.19.1/s7",
3740
+ "fragment": "clause-6.19.1",
3741
+ "clause": "6.19.1",
3742
+ "kind": "provision",
3743
+ "fragment_normative": true,
3744
+ "modality": "informative",
3745
+ "text": "Measurement no."
3746
+ },
3747
+ {
3748
+ "address": "clause-6.19.1/s8",
3749
+ "fragment": "clause-6.19.1",
3750
+ "clause": "6.19.1",
3751
+ "kind": "provision",
3752
+ "fragment_normative": true,
3753
+ "modality": "informative",
3754
+ "text": "2:"
3755
+ },
3756
+ {
3757
+ "address": "clause-6.19.1/s9",
3758
+ "fragment": "clause-6.19.1",
3759
+ "clause": "6.19.1",
3760
+ "kind": "provision",
3761
+ "fragment_normative": true,
3762
+ "modality": "informative",
3763
+ "text": "Evaluator: ____________________ Remarks:"
3764
+ },
3765
+ {
3766
+ "address": "clause-6.19.1/s10",
3767
+ "fragment": "clause-6.19.1",
3768
+ "clause": "6.19.1",
3769
+ "kind": "provision",
3770
+ "fragment_normative": true,
3771
+ "modality": "informative",
3772
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3773
+ },
3774
+ {
3775
+ "address": "clause-6.19.1/s11",
3776
+ "fragment": "clause-6.19.1",
3777
+ "clause": "6.19.1",
3778
+ "kind": "provision",
3779
+ "fragment_normative": true,
3780
+ "modality": "informative",
3781
+ "text": "Measurement no."
3782
+ },
3783
+ {
3784
+ "address": "clause-6.19.1/s12",
3785
+ "fragment": "clause-6.19.1",
3786
+ "clause": "6.19.1",
3787
+ "kind": "provision",
3788
+ "fragment_normative": true,
3789
+ "modality": "informative",
3790
+ "text": "3:"
3791
+ },
3792
+ {
3793
+ "address": "clause-6.19.1/s13",
3794
+ "fragment": "clause-6.19.1",
3795
+ "clause": "6.19.1",
3796
+ "kind": "provision",
3797
+ "fragment_normative": true,
3798
+ "modality": "informative",
3799
+ "text": "Evaluator: ____________________ Remarks:"
3800
+ },
3801
+ {
3802
+ "address": "clause-6.19.1/s14",
3803
+ "fragment": "clause-6.19.1",
3804
+ "clause": "6.19.1",
3805
+ "kind": "provision",
3806
+ "fragment_normative": true,
3807
+ "modality": "informative",
3808
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3809
+ },
3810
+ {
3811
+ "address": "clause-6.19.1/s15",
3812
+ "fragment": "clause-6.19.1",
3813
+ "clause": "6.19.1",
3814
+ "kind": "provision",
3815
+ "fragment_normative": true,
3816
+ "modality": "informative",
3817
+ "text": "Measurement no."
3818
+ },
3819
+ {
3820
+ "address": "clause-6.19.1/s16",
3821
+ "fragment": "clause-6.19.1",
3822
+ "clause": "6.19.1",
3823
+ "kind": "provision",
3824
+ "fragment_normative": true,
3825
+ "modality": "informative",
3826
+ "text": "4:"
3827
+ },
3828
+ {
3829
+ "address": "clause-6.19.1/s17",
3830
+ "fragment": "clause-6.19.1",
3831
+ "clause": "6.19.1",
3832
+ "kind": "provision",
3833
+ "fragment_normative": true,
3834
+ "modality": "informative",
3835
+ "text": "Evaluator: ____________________ Remarks:"
3836
+ },
3837
+ {
3838
+ "address": "clause-6.19.1/s18",
3839
+ "fragment": "clause-6.19.1",
3840
+ "clause": "6.19.1",
3841
+ "kind": "provision",
3842
+ "fragment_normative": true,
3843
+ "modality": "informative",
3844
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3845
+ },
3846
+ {
3847
+ "address": "clause-6.19.1/s19",
3848
+ "fragment": "clause-6.19.1",
3849
+ "clause": "6.19.1",
3850
+ "kind": "provision",
3851
+ "fragment_normative": true,
3852
+ "modality": "informative",
3853
+ "text": "Measurement no."
3854
+ },
3855
+ {
3856
+ "address": "clause-6.19.1/s20",
3857
+ "fragment": "clause-6.19.1",
3858
+ "clause": "6.19.1",
3859
+ "kind": "provision",
3860
+ "fragment_normative": true,
3861
+ "modality": "informative",
3862
+ "text": "5:"
3863
+ },
3864
+ {
3865
+ "address": "clause-6.19.1/s21",
3866
+ "fragment": "clause-6.19.1",
3867
+ "clause": "6.19.1",
3868
+ "kind": "provision",
3869
+ "fragment_normative": true,
3870
+ "modality": "informative",
3871
+ "text": "Evaluator: ____________________ Remarks:"
3872
+ },
3873
+ {
3874
+ "address": "clause-6.19.1/s22",
3875
+ "fragment": "clause-6.19.1",
3876
+ "clause": "6.19.1",
3877
+ "kind": "provision",
3878
+ "fragment_normative": true,
3879
+ "modality": "informative",
3880
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3881
+ },
3882
+ {
3883
+ "address": "clause-6.19.1/s23",
3884
+ "fragment": "clause-6.19.1",
3885
+ "clause": "6.19.1",
3886
+ "kind": "provision",
3887
+ "fragment_normative": true,
3888
+ "modality": "informative",
3889
+ "text": "Measurement no."
3890
+ },
3891
+ {
3892
+ "address": "clause-6.19.1/s24",
3893
+ "fragment": "clause-6.19.1",
3894
+ "clause": "6.19.1",
3895
+ "kind": "provision",
3896
+ "fragment_normative": true,
3897
+ "modality": "informative",
3898
+ "text": "6:"
3899
+ },
3900
+ {
3901
+ "address": "clause-6.19.1/s25",
3902
+ "fragment": "clause-6.19.1",
3903
+ "clause": "6.19.1",
3904
+ "kind": "provision",
3905
+ "fragment_normative": true,
3906
+ "modality": "informative",
3907
+ "text": "Evaluator: ____________________ Remarks:"
3908
+ },
3909
+ {
3910
+ "address": "clause-6.19.1/s26",
3911
+ "fragment": "clause-6.19.1",
3912
+ "clause": "6.19.1",
3913
+ "kind": "provision",
3914
+ "fragment_normative": true,
3915
+ "modality": "informative",
3916
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3917
+ },
3918
+ {
3919
+ "address": "clause-6.19.1/s27",
3920
+ "fragment": "clause-6.19.1",
3921
+ "clause": "6.19.1",
3922
+ "kind": "provision",
3923
+ "fragment_normative": true,
3924
+ "modality": "informative",
3925
+ "text": "Measurement no."
3926
+ },
3927
+ {
3928
+ "address": "clause-6.19.1/s28",
3929
+ "fragment": "clause-6.19.1",
3930
+ "clause": "6.19.1",
3931
+ "kind": "provision",
3932
+ "fragment_normative": true,
3933
+ "modality": "informative",
3934
+ "text": "7:"
3935
+ },
3936
+ {
3937
+ "address": "clause-6.19.1/s29",
3938
+ "fragment": "clause-6.19.1",
3939
+ "clause": "6.19.1",
3940
+ "kind": "provision",
3941
+ "fragment_normative": true,
3942
+ "modality": "informative",
3943
+ "text": "Evaluator: ____________________ Remarks:"
3944
+ },
3945
+ {
3946
+ "address": "clause-6.19.1/s30",
3947
+ "fragment": "clause-6.19.1",
3948
+ "clause": "6.19.1",
3949
+ "kind": "provision",
3950
+ "fragment_normative": true,
3951
+ "modality": "informative",
3952
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3953
+ },
3954
+ {
3955
+ "address": "clause-6.19.1/s31",
3956
+ "fragment": "clause-6.19.1",
3957
+ "clause": "6.19.1",
3958
+ "kind": "provision",
3959
+ "fragment_normative": true,
3960
+ "modality": "informative",
3961
+ "text": "Measurement no."
3962
+ },
3963
+ {
3964
+ "address": "clause-6.19.1/s32",
3965
+ "fragment": "clause-6.19.1",
3966
+ "clause": "6.19.1",
3967
+ "kind": "provision",
3968
+ "fragment_normative": true,
3969
+ "modality": "informative",
3970
+ "text": "8:"
3971
+ },
3972
+ {
3973
+ "address": "clause-6.19.1/s33",
3974
+ "fragment": "clause-6.19.1",
3975
+ "clause": "6.19.1",
3976
+ "kind": "provision",
3977
+ "fragment_normative": true,
3978
+ "modality": "informative",
3979
+ "text": "Evaluator: ____________________ Remarks:"
3980
+ },
3981
+ {
3982
+ "address": "clause-6.19.1/s34",
3983
+ "fragment": "clause-6.19.1",
3984
+ "clause": "6.19.1",
3985
+ "kind": "provision",
3986
+ "fragment_normative": true,
3987
+ "modality": "informative",
3988
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
3989
+ },
3990
+ {
3991
+ "address": "clause-6.19.1/note-1/s1",
3992
+ "fragment": "clause-6.19.1/note-1",
3993
+ "kind": "note",
3994
+ "fragment_normative": false,
3995
+ "modality": "informative",
3996
+ "text": "Span is the result of subtracting the average indication at minimum test load from the average indication at maximum test load."
3997
+ },
3998
+ {
3999
+ "address": "clause-6.19.1/note-1/s2",
4000
+ "fragment": "clause-6.19.1/note-1",
4001
+ "kind": "note",
4002
+ "fragment_normative": false,
4003
+ "modality": "informative",
4004
+ "text": "Absolute (not relative) time shall be recorded."
4005
+ },
4006
+ {
4007
+ "address": "clause-6.19.2/s1",
4008
+ "fragment": "clause-6.19.2",
4009
+ "clause": "6.19.2",
4010
+ "kind": "provision",
4011
+ "fragment_normative": true,
4012
+ "modality": "informative",
4013
+ "text": "R 60-1, 5.7.2.6 R 60-2, 2.10.7.11 R 60-3, 2.2.9"
4014
+ },
4015
+ {
4016
+ "address": "clause-6.19.2/s2",
4017
+ "fragment": "clause-6.19.2",
4018
+ "clause": "6.19.2",
4019
+ "kind": "provision",
4020
+ "fragment_normative": true,
4021
+ "modality": "informative",
4022
+ "text": "Evaluator: ____________________ Remarks:"
4023
+ },
4024
+ {
4025
+ "address": "clause-6.19.2/s3",
4026
+ "fragment": "clause-6.19.2",
4027
+ "clause": "6.19.2",
4028
+ "kind": "provision",
4029
+ "fragment_normative": true,
4030
+ "modality": "informative",
4031
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4032
+ },
4033
+ {
4034
+ "address": "clause-6.19.2/s4",
4035
+ "fragment": "clause-6.19.2",
4036
+ "clause": "6.19.2",
4037
+ "kind": "provision",
4038
+ "fragment_normative": true,
4039
+ "modality": "informative",
4040
+ "text": "Evaluator: ____________________ Remarks:"
4041
+ },
4042
+ {
4043
+ "address": "clause-6.19.2/s5",
4044
+ "fragment": "clause-6.19.2",
4045
+ "clause": "6.19.2",
4046
+ "kind": "provision",
4047
+ "fragment_normative": true,
4048
+ "modality": "informative",
4049
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4050
+ },
4051
+ {
4052
+ "address": "clause-6.19.2/s6",
4053
+ "fragment": "clause-6.19.2",
4054
+ "clause": "6.19.2",
4055
+ "kind": "provision",
4056
+ "fragment_normative": true,
4057
+ "modality": "informative",
4058
+ "text": "Evaluator: ____________________ Remarks:"
4059
+ },
4060
+ {
4061
+ "address": "clause-6.19.2/s7",
4062
+ "fragment": "clause-6.19.2",
4063
+ "clause": "6.19.2",
4064
+ "kind": "provision",
4065
+ "fragment_normative": true,
4066
+ "modality": "informative",
4067
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4068
+ },
4069
+ {
4070
+ "address": "clause-6.19.2/s8",
4071
+ "fragment": "clause-6.19.2",
4072
+ "clause": "6.19.2",
4073
+ "kind": "provision",
4074
+ "fragment_normative": true,
4075
+ "modality": "informative",
4076
+ "text": "Evaluator: ____________________ Remarks:"
4077
+ },
4078
+ {
4079
+ "address": "clause-6.19.2/s9",
4080
+ "fragment": "clause-6.19.2",
4081
+ "clause": "6.19.2",
4082
+ "kind": "provision",
4083
+ "fragment_normative": true,
4084
+ "modality": "informative",
4085
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4086
+ },
4087
+ {
4088
+ "address": "clause-6.19.2/s10",
4089
+ "fragment": "clause-6.19.2",
4090
+ "clause": "6.19.2",
4091
+ "kind": "provision",
4092
+ "fragment_normative": true,
4093
+ "modality": "informative",
4094
+ "text": "Evaluator: ____________________ Remarks:"
4095
+ },
4096
+ {
4097
+ "address": "clause-6.19.2/s11",
4098
+ "fragment": "clause-6.19.2",
4099
+ "clause": "6.19.2",
4100
+ "kind": "provision",
4101
+ "fragment_normative": true,
4102
+ "modality": "informative",
4103
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4104
+ },
4105
+ {
4106
+ "address": "clause-6.19.2/s12",
4107
+ "fragment": "clause-6.19.2",
4108
+ "clause": "6.19.2",
4109
+ "kind": "provision",
4110
+ "fragment_normative": true,
4111
+ "modality": "informative",
4112
+ "text": "Evaluator: ____________________ Remarks:"
4113
+ },
4114
+ {
4115
+ "address": "clause-6.19.2/s13",
4116
+ "fragment": "clause-6.19.2",
4117
+ "clause": "6.19.2",
4118
+ "kind": "provision",
4119
+ "fragment_normative": true,
4120
+ "modality": "informative",
4121
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4122
+ },
4123
+ {
4124
+ "address": "clause-6.19.2/s14",
4125
+ "fragment": "clause-6.19.2",
4126
+ "clause": "6.19.2",
4127
+ "kind": "provision",
4128
+ "fragment_normative": true,
4129
+ "modality": "informative",
4130
+ "text": "Evaluator: ____________________ Remarks:"
4131
+ },
4132
+ {
4133
+ "address": "clause-6.19.2/s15",
4134
+ "fragment": "clause-6.19.2",
4135
+ "clause": "6.19.2",
4136
+ "kind": "provision",
4137
+ "fragment_normative": true,
4138
+ "modality": "informative",
4139
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4140
+ },
4141
+ {
4142
+ "address": "clause-6.19.2/s16",
4143
+ "fragment": "clause-6.19.2",
4144
+ "clause": "6.19.2",
4145
+ "kind": "provision",
4146
+ "fragment_normative": true,
4147
+ "modality": "informative",
4148
+ "text": "Evaluator: ____________________ Remarks:"
4149
+ },
4150
+ {
4151
+ "address": "clause-6.19.2/s17",
4152
+ "fragment": "clause-6.19.2",
4153
+ "clause": "6.19.2",
4154
+ "kind": "provision",
4155
+ "fragment_normative": true,
4156
+ "modality": "informative",
4157
+ "text": "Date: Time: Temperature: \"unitsml(degC)\" Relative humidity: % Barometric pressure: \"unitsml(kPa)\""
4158
+ },
4159
+ {
4160
+ "address": "clause-6.19.2/note-1/s1",
4161
+ "fragment": "clause-6.19.2/note-1",
4162
+ "kind": "note",
4163
+ "fragment_normative": false,
4164
+ "modality": "informative",
4165
+ "text": "Span is the result of subtracting the average indication at minimum test load from the average indication at maximum test load."
4166
+ },
4167
+ {
4168
+ "address": "clause-6.19.2/note-1/s2",
4169
+ "fragment": "clause-6.19.2/note-1",
4170
+ "kind": "note",
4171
+ "fragment_normative": false,
4172
+ "modality": "informative",
4173
+ "text": "Absolute (not relative) time shall be recorded."
4174
+ },
4175
+ {
4176
+ "address": "clause-6.19.3/s1",
4177
+ "fragment": "clause-6.19.3",
4178
+ "clause": "6.19.3",
4179
+ "kind": "provision",
4180
+ "fragment_normative": true,
4181
+ "modality": "informative",
4182
+ "text": "R 60-1, 5.7.2.6 R 60-2, 2.10.7.11 R 60-3, 2.2.9"
4183
+ },
4184
+ {
4185
+ "address": "clause-6.19.3/s2",
4186
+ "fragment": "clause-6.19.3",
4187
+ "clause": "6.19.3",
4188
+ "kind": "provision",
4189
+ "fragment_normative": true,
4190
+ "modality": "informative",
4191
+ "text": "Application no.: Load cell model: Serial no.: E_{\"max\"}: n_{\"LC\"}: v_{\"min\"}: p_{\"LC\"}: DR: Force-generating system: Indicating instrument: Evaluator:"
4192
+ },
4193
+ {
4194
+ "address": "clause-6.19.3/s3",
4195
+ "fragment": "clause-6.19.3",
4196
+ "clause": "6.19.3",
4197
+ "kind": "provision",
4198
+ "fragment_normative": true,
4199
+ "modality": "informative",
4200
+ "text": "PASS: ☐ FAIL: ☐"
4201
+ },
4202
+ {
4203
+ "address": "clause-6.19.3/s4",
4204
+ "fragment": "clause-6.19.3",
4205
+ "clause": "6.19.3",
4206
+ "kind": "provision",
4207
+ "fragment_normative": true,
4208