@oimlsmart/primmel-packages 0.1.0

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (460) hide show
  1. package/AGENTS.md +60 -0
  2. package/LICENSE +21 -0
  3. package/README.md +68 -0
  4. package/acme-cgm-200/model/cgm200.prl +284 -0
  5. package/acme-cgm-200/model/r144-map.prl +337 -0
  6. package/acme-cgm-200/package.primmel +39 -0
  7. package/acme-cgm-system/model/cgm-system.prl +125 -0
  8. package/acme-cgm-system/model/r144-map.prl +75 -0
  9. package/acme-cgm-system/model/sample-line.prl +42 -0
  10. package/acme-cgm-system/package.primmel +23 -0
  11. package/acme-lc500/model/lc500.prl +218 -0
  12. package/acme-lc500/model/passport.prl +43 -0
  13. package/acme-lc500/model/r60-map.prl +161 -0
  14. package/acme-lc500/model/twin-cert-map.prl +114 -0
  15. package/acme-lc500/package.primmel +35 -0
  16. package/acme-md3xx/model/md350.prl +317 -0
  17. package/acme-md3xx/model/r129-map.prl +346 -0
  18. package/acme-md3xx/package.primmel +49 -0
  19. package/acme-rs180/model/r91-map.prl +234 -0
  20. package/acme-rs180/model/rs180.prl +236 -0
  21. package/acme-rs180/package.primmel +47 -0
  22. package/ims-demo/model/ims.prl +23 -0
  23. package/ims-demo/model/isms-map.prl +60 -0
  24. package/ims-demo/model/qms-map.prl +73 -0
  25. package/ims-demo/package.primmel +42 -0
  26. package/isms-ref/model/isms.prl +34 -0
  27. package/isms-ref/package.primmel +35 -0
  28. package/iso-iec-17000/package.primmel +8 -0
  29. package/iso-iec-17000/terminology.prl +268 -0
  30. package/iso-iec-17025/package.primmel +10 -0
  31. package/iso-iec-17025/specification/requirements/lab.prl +474 -0
  32. package/iso-iec-17025/terminology.prl +72 -0
  33. package/iso-iec-17065/package.primmel +10 -0
  34. package/iso-iec-17065/specification/requirements/body.prl +446 -0
  35. package/iso-iec-17065/terminology.prl +103 -0
  36. package/iso-iec-17067/package.primmel +10 -0
  37. package/iso-iec-17067/specification/requirements/scheme-content.prl +300 -0
  38. package/iso-iec-17067/terminology.prl +24 -0
  39. package/oiml-cs/package.primmel +10 -0
  40. package/oiml-cs/specification/discrepancies.prl +26 -0
  41. package/oiml-cs/specification/requirements/cs.prl +515 -0
  42. package/oiml-cs-dataspace/.primmel-allowlist.prl +25 -0
  43. package/oiml-cs-dataspace/package.primmel +9 -0
  44. package/oiml-cs-dataspace/specification/dataspace.prl +73 -0
  45. package/oiml-cs-dataspace/specification/policies.prl +68 -0
  46. package/oiml-integrated-ref/model/probe-pairing.prl +71 -0
  47. package/oiml-integrated-ref/package.primmel +10 -0
  48. package/oiml-r129/.primmel-allowlist.prl +2 -0
  49. package/oiml-r129/evaluation/processes.prl +152 -0
  50. package/oiml-r129/evaluation/workflow.prl +48 -0
  51. package/oiml-r129/execution/forms/admin/adjustments-modifications.prl +30 -0
  52. package/oiml-r129/execution/forms/admin/checklist.prl +70 -0
  53. package/oiml-r129/execution/forms/admin/configuration.prl +31 -0
  54. package/oiml-r129/execution/forms/admin/equipment-info.prl +27 -0
  55. package/oiml-r129/execution/forms/admin/general-info.prl +63 -0
  56. package/oiml-r129/execution/forms/admin/identification.prl +49 -0
  57. package/oiml-r129/execution/forms/admin/sample-selection.prl +30 -0
  58. package/oiml-r129/execution/forms/admin/summary-results.prl +50 -0
  59. package/oiml-r129/execution/forms/emc/bursts.prl +88 -0
  60. package/oiml-r129/execution/forms/emc/esd.prl +66 -0
  61. package/oiml-r129/execution/forms/emc/low-voltage-battery.prl +58 -0
  62. package/oiml-r129/execution/forms/emc/rf-immunity-conducted.prl +59 -0
  63. package/oiml-r129/execution/forms/emc/rf-immunity-radiated.prl +59 -0
  64. package/oiml-r129/execution/forms/emc/surge.prl +61 -0
  65. package/oiml-r129/execution/forms/emc/voltage-dips.prl +62 -0
  66. package/oiml-r129/execution/forms/emc/voltage-variation.prl +58 -0
  67. package/oiml-r129/execution/forms/env/damp-heat-cyclic.prl +43 -0
  68. package/oiml-r129/execution/forms/env/damp-heat-steady.prl +50 -0
  69. package/oiml-r129/execution/forms/env/static-temperatures.prl +61 -0
  70. package/oiml-r129/execution/forms/shared/headers.prl +86 -0
  71. package/oiml-r129/execution/forms/tests/acoustics.prl +44 -0
  72. package/oiml-r129/execution/forms/tests/ambient-light.prl +46 -0
  73. package/oiml-r129/execution/forms/tests/construction-examination.prl +46 -0
  74. package/oiml-r129/execution/forms/tests/examination-checklist.prl +51 -0
  75. package/oiml-r129/execution/forms/tests/object-shape.prl +43 -0
  76. package/oiml-r129/execution/forms/tests/orientation-position.prl +31 -0
  77. package/oiml-r129/execution/forms/tests/repeatability.prl +65 -0
  78. package/oiml-r129/execution/forms/tests/speed-movement.prl +59 -0
  79. package/oiml-r129/execution/forms/tests/surface-characteristics.prl +44 -0
  80. package/oiml-r129/execution/forms/tests/warm-up-time.prl +35 -0
  81. package/oiml-r129/execution/subforms/dimension-measurement.prl +93 -0
  82. package/oiml-r129/layers.prl +50 -0
  83. package/oiml-r129/model/attributes.prl +243 -0
  84. package/oiml-r129/model/behaviors.prl +79 -0
  85. package/oiml-r129/model/capabilities.prl +29 -0
  86. package/oiml-r129/model/characteristics.prl +8 -0
  87. package/oiml-r129/model/conditions.prl +23 -0
  88. package/oiml-r129/model/instrument.prl +67 -0
  89. package/oiml-r129/model/state.prl +22 -0
  90. package/oiml-r129/model/twin.prl +23 -0
  91. package/oiml-r129/package.primmel +15 -0
  92. package/oiml-r129/payload/application.yaml +40 -0
  93. package/oiml-r129/payload/conditions-common-test.yaml +8 -0
  94. package/oiml-r129/payload/formulas-variants.yaml +33 -0
  95. package/oiml-r129/payload/promises.yaml +102 -0
  96. package/oiml-r129/payload/sample-data.yaml +300 -0
  97. package/oiml-r129/references.prl +306 -0
  98. package/oiml-r129/sources-prd/coverage.json +59 -0
  99. package/oiml-r129/sources-prd/r129-1.sentences.json +4238 -0
  100. package/oiml-r129/sources-prd/r129-2.sentences.json +1139 -0
  101. package/oiml-r129/sources-prd/r129-3.sentences.json +3809 -0
  102. package/oiml-r129/sources-prd/r129-4.sentences.json +1227 -0
  103. package/oiml-r129/specification/calculations.prl +83 -0
  104. package/oiml-r129/specification/conformance/disturbance-tests.prl +212 -0
  105. package/oiml-r129/specification/conformance/effect-tests.prl +70 -0
  106. package/oiml-r129/specification/conformance/examinations.prl +83 -0
  107. package/oiml-r129/specification/conformance/metrological-tests.prl +178 -0
  108. package/oiml-r129/specification/formulas.prl +9 -0
  109. package/oiml-r129/specification/requirements/electronic.prl +46 -0
  110. package/oiml-r129/specification/requirements/metrological.prl +83 -0
  111. package/oiml-r129/specification/requirements/object-limitations.prl +99 -0
  112. package/oiml-r129/specification/requirements/software.prl +57 -0
  113. package/oiml-r129/specification/requirements/technical.prl +134 -0
  114. package/oiml-r129/specification/symbols.prl +187 -0
  115. package/oiml-r129/specification/tables.prl +74 -0
  116. package/oiml-r129/terminology.prl +415 -0
  117. package/oiml-r129/value-types.prl +40 -0
  118. package/oiml-r144/.primmel-allowlist.prl +2 -0
  119. package/oiml-r144/entities/instrument.prl +360 -0
  120. package/oiml-r144/entities/test-execution.prl +228 -0
  121. package/oiml-r144/entities/workflow.prl +2075 -0
  122. package/oiml-r144/evaluation/processes.prl +152 -0
  123. package/oiml-r144/evaluation/workflow.prl +48 -0
  124. package/oiml-r144/execution/forms/sec-3-report/03-01-laboratory-info.prl +19 -0
  125. package/oiml-r144/execution/forms/sec-3-report/03-02-test-location.prl +14 -0
  126. package/oiml-r144/execution/forms/sec-3-report/03-03-manufacturer-info.prl +18 -0
  127. package/oiml-r144/execution/forms/sec-3-report/03-04-applicant-info.prl +19 -0
  128. package/oiml-r144/execution/forms/sec-3-report/03-05-type-identification.prl +80 -0
  129. package/oiml-r144/execution/forms/sec-3-report/03-06-type-composition.prl +31 -0
  130. package/oiml-r144/execution/forms/sec-3-report/03-07-visual-examination.prl +46 -0
  131. package/oiml-r144/execution/forms/sec-3-report/03-08-test-conclusions.prl +46 -0
  132. package/oiml-r144/execution/forms/sec-3-report/03-09-general-conclusion.prl +19 -0
  133. package/oiml-r144/execution/forms/sec-3-report/03-10-responsible-persons.prl +27 -0
  134. package/oiml-r144/execution/forms/sec-tests/ambient-pressure-test.prl +59 -0
  135. package/oiml-r144/execution/forms/sec-tests/bursts-mains-test.prl +52 -0
  136. package/oiml-r144/execution/forms/sec-tests/bursts-signal-test.prl +55 -0
  137. package/oiml-r144/execution/forms/sec-tests/cold-test.prl +48 -0
  138. package/oiml-r144/execution/forms/sec-tests/cross-sensitivity-test.prl +92 -0
  139. package/oiml-r144/execution/forms/sec-tests/damp-heat-test.prl +50 -0
  140. package/oiml-r144/execution/forms/sec-tests/documentation-examination.prl +52 -0
  141. package/oiml-r144/execution/forms/sec-tests/drift-test.prl +83 -0
  142. package/oiml-r144/execution/forms/sec-tests/dry-heat-test.prl +53 -0
  143. package/oiml-r144/execution/forms/sec-tests/error-determination.prl +37 -0
  144. package/oiml-r144/execution/forms/sec-tests/esd-test.prl +53 -0
  145. package/oiml-r144/execution/forms/sec-tests/flow-spillover-test.prl +83 -0
  146. package/oiml-r144/execution/forms/sec-tests/leakproofness-test.prl +41 -0
  147. package/oiml-r144/execution/forms/sec-tests/low-battery-test.prl +48 -0
  148. package/oiml-r144/execution/forms/sec-tests/power-reduction-test.prl +49 -0
  149. package/oiml-r144/execution/forms/sec-tests/power-supply-test.prl +57 -0
  150. package/oiml-r144/execution/forms/sec-tests/repeatability-test.prl +60 -0
  151. package/oiml-r144/execution/forms/sec-tests/response-time-test.prl +43 -0
  152. package/oiml-r144/execution/forms/sec-tests/rf-emf-test.prl +47 -0
  153. package/oiml-r144/execution/forms/sec-tests/shock-test.prl +50 -0
  154. package/oiml-r144/execution/forms/sec-tests/surge-test.prl +52 -0
  155. package/oiml-r144/execution/forms/sec-tests/vibration-test.prl +58 -0
  156. package/oiml-r144/execution/forms/sec-tests/warm-up-time-test.prl +69 -0
  157. package/oiml-r144/execution/forms/shared/headers.prl +132 -0
  158. package/oiml-r144/execution/subforms/cgm-point.prl +99 -0
  159. package/oiml-r144/layers.prl +44 -0
  160. package/oiml-r144/model/attributes.prl +679 -0
  161. package/oiml-r144/model/behaviors.prl +117 -0
  162. package/oiml-r144/model/capabilities.prl +99 -0
  163. package/oiml-r144/model/characteristics.prl +27 -0
  164. package/oiml-r144/model/conditions.prl +46 -0
  165. package/oiml-r144/model/instrument.prl +85 -0
  166. package/oiml-r144/model/state.prl +18 -0
  167. package/oiml-r144/model/twin.prl +25 -0
  168. package/oiml-r144/package.primmel +15 -0
  169. package/oiml-r144/payload/application.yaml +80 -0
  170. package/oiml-r144/payload/attributes-pair-list.yaml +18 -0
  171. package/oiml-r144/payload/conditions-common-test.yaml +74 -0
  172. package/oiml-r144/payload/formulas-variants.yaml +32 -0
  173. package/oiml-r144/payload/promises.yaml +118 -0
  174. package/oiml-r144/payload/sample-data.yaml +643 -0
  175. package/oiml-r144/references.prl +594 -0
  176. package/oiml-r144/sources-prd/coverage.json +114 -0
  177. package/oiml-r144/sources-prd/r144-1.sentences.json +2797 -0
  178. package/oiml-r144/sources-prd/r144-2.sentences.json +1627 -0
  179. package/oiml-r144/sources-prd/r144-3.sentences.json +838 -0
  180. package/oiml-r144/specification/calculations.prl +123 -0
  181. package/oiml-r144/specification/conformance/examination.prl +87 -0
  182. package/oiml-r144/specification/conformance/performance-tests.prl +755 -0
  183. package/oiml-r144/specification/formulas.prl +37 -0
  184. package/oiml-r144/specification/reference-materials.prl +87 -0
  185. package/oiml-r144/specification/requirements/controls.prl +51 -0
  186. package/oiml-r144/specification/requirements/metrological.prl +299 -0
  187. package/oiml-r144/specification/requirements/report.prl +35 -0
  188. package/oiml-r144/specification/requirements/technical.prl +455 -0
  189. package/oiml-r144/specification/symbols.prl +357 -0
  190. package/oiml-r144/specification/tables.prl +95 -0
  191. package/oiml-r144/specification/test-point-sets.prl +15 -0
  192. package/oiml-r144/terminology.prl +308 -0
  193. package/oiml-r144/value-types.prl +49 -0
  194. package/oiml-r60/.primmel-allowlist.prl +2 -0
  195. package/oiml-r60/entities/workflow.prl +2079 -0
  196. package/oiml-r60/evaluation/processes.prl +152 -0
  197. package/oiml-r60/evaluation/workflow.prl +48 -0
  198. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-01-authority-info.prl +76 -0
  199. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-02-synopsis.prl +20 -0
  200. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-01-examinations.prl +27 -0
  201. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-a-performance-general.prl +81 -0
  202. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-03-02-b-performance-digital.prl +104 -0
  203. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-01-manufacturer.prl +21 -0
  204. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-02-applicant.prl +44 -0
  205. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-04-03-testing-laboratories.prl +69 -0
  206. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-05-load-cell-type-info.prl +83 -0
  207. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-06-accessories.prl +41 -0
  208. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-07-sample-selection.prl +71 -0
  209. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-01-general-info.prl +103 -0
  210. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-02-performance-info.prl +66 -0
  211. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-03-digital-info.prl +35 -0
  212. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-04-photographs.prl +12 -0
  213. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-05-documentation.prl +27 -0
  214. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-06-inscriptions.prl +126 -0
  215. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-07-model-range.prl +143 -0
  216. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-09-12-previous-tests.prl +26 -0
  217. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-01-force-generating-system.prl +89 -0
  218. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-02-weights.prl +61 -0
  219. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-03-temperature-chamber.prl +96 -0
  220. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-04-climate-chamber.prl +96 -0
  221. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-05-indicator.prl +92 -0
  222. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-06-terminal.prl +86 -0
  223. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-07-barometric-pressure-meter.prl +62 -0
  224. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-08-thermometer.prl +62 -0
  225. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-09-moisture-analyser.prl +62 -0
  226. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-10-additional-test-equipment.prl +69 -0
  227. package/oiml-r60/execution/forms/sec-4-evaluation-report/04-10-11-remarks.prl +11 -0
  228. package/oiml-r60/execution/forms/sec-4-evaluation-report/test-usage-matrix.prl +85 -0
  229. package/oiml-r60/execution/forms/sec-5-examination/documentation-examination.prl +53 -0
  230. package/oiml-r60/execution/forms/sec-5-examination/marking-examination.prl +104 -0
  231. package/oiml-r60/execution/forms/sec-5-examination/software-examination.prl +86 -0
  232. package/oiml-r60/execution/forms/sec-5-examination/suitability-examination.prl +56 -0
  233. package/oiml-r60/execution/forms/sec-6-performance-tests/barometric-pressure.prl +176 -0
  234. package/oiml-r60/execution/forms/sec-6-performance-tests/bursts.prl +129 -0
  235. package/oiml-r60/execution/forms/sec-6-performance-tests/conducted-emc.prl +170 -0
  236. package/oiml-r60/execution/forms/sec-6-performance-tests/creep-dr.prl +327 -0
  237. package/oiml-r60/execution/forms/sec-6-performance-tests/emc-susceptibility.prl +115 -0
  238. package/oiml-r60/execution/forms/sec-6-performance-tests/esd.prl +224 -0
  239. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-ch.prl +300 -0
  240. package/oiml-r60/execution/forms/sec-6-performance-tests/humidity-sh.prl +235 -0
  241. package/oiml-r60/execution/forms/sec-6-performance-tests/initial-tests.prl +129 -0
  242. package/oiml-r60/execution/forms/sec-6-performance-tests/load-cell-errors.prl +280 -0
  243. package/oiml-r60/execution/forms/sec-6-performance-tests/load-test.prl +29 -0
  244. package/oiml-r60/execution/forms/sec-6-performance-tests/performance-test-summary.prl +82 -0
  245. package/oiml-r60/execution/forms/sec-6-performance-tests/power-voltage.prl +166 -0
  246. package/oiml-r60/execution/forms/sec-6-performance-tests/repeatability.prl +189 -0
  247. package/oiml-r60/execution/forms/sec-6-performance-tests/short-time-power.prl +98 -0
  248. package/oiml-r60/execution/forms/sec-6-performance-tests/span-stability.prl +242 -0
  249. package/oiml-r60/execution/forms/sec-6-performance-tests/surge.prl +142 -0
  250. package/oiml-r60/execution/forms/sec-6-performance-tests/temperature-mdlo.prl +180 -0
  251. package/oiml-r60/execution/forms/sec-6-performance-tests/warm-up-time.prl +207 -0
  252. package/oiml-r60/execution/forms/shared/headers.prl +255 -0
  253. package/oiml-r60/execution/subforms/load-test-row.prl +55 -0
  254. package/oiml-r60/execution/subforms/test-procedures.prl +33 -0
  255. package/oiml-r60/layers.prl +46 -0
  256. package/oiml-r60/model/attributes.prl +642 -0
  257. package/oiml-r60/model/behaviors.prl +165 -0
  258. package/oiml-r60/model/capabilities.prl +57 -0
  259. package/oiml-r60/model/characteristics.prl +27 -0
  260. package/oiml-r60/model/conditions.prl +50 -0
  261. package/oiml-r60/model/instrument.prl +96 -0
  262. package/oiml-r60/model/processes.prl +54 -0
  263. package/oiml-r60/model/state.prl +22 -0
  264. package/oiml-r60/model/twin.prl +16 -0
  265. package/oiml-r60/package.primmel +16 -0
  266. package/oiml-r60/payload/annexes-part4.yaml +122 -0
  267. package/oiml-r60/payload/application.yaml +83 -0
  268. package/oiml-r60/payload/conditions-common-test.yaml +121 -0
  269. package/oiml-r60/payload/formulas-variants.yaml +55 -0
  270. package/oiml-r60/payload/promises.yaml +224 -0
  271. package/oiml-r60/payload/sample-data.yaml +5025 -0
  272. package/oiml-r60/payload/symbols-formula-notes.yaml +21 -0
  273. package/oiml-r60/references.prl +549 -0
  274. package/oiml-r60/sources-prd/coverage.json +740 -0
  275. package/oiml-r60/sources-prd/r60-1.sentences.json +2173 -0
  276. package/oiml-r60/sources-prd/r60-2.sentences.json +2961 -0
  277. package/oiml-r60/sources-prd/r60-3.sentences.json +4212 -0
  278. package/oiml-r60/sources-prd/r60-a.sentences.json +3361 -0
  279. package/oiml-r60/specification/calculations.prl +318 -0
  280. package/oiml-r60/specification/conformance/class-specific.prl +1120 -0
  281. package/oiml-r60/specification/conformance/electronic.prl +483 -0
  282. package/oiml-r60/specification/conformance/examination.prl +183 -0
  283. package/oiml-r60/specification/conformance/metrological.prl +478 -0
  284. package/oiml-r60/specification/constraints.prl +58 -0
  285. package/oiml-r60/specification/formulas-used.prl +43 -0
  286. package/oiml-r60/specification/formulas.prl +20 -0
  287. package/oiml-r60/specification/requirements/class-specific.prl +655 -0
  288. package/oiml-r60/specification/requirements/classification.prl +114 -0
  289. package/oiml-r60/specification/requirements/electronic.prl +222 -0
  290. package/oiml-r60/specification/requirements/metrological.prl +381 -0
  291. package/oiml-r60/specification/requirements/technical.prl +146 -0
  292. package/oiml-r60/specification/symbols.prl +599 -0
  293. package/oiml-r60/specification/tables.prl +182 -0
  294. package/oiml-r60/specification/test-sequences.prl +72 -0
  295. package/oiml-r60/terminology.prl +920 -0
  296. package/oiml-r60/value-types.prl +46 -0
  297. package/oiml-r91/.primmel-allowlist.prl +3 -0
  298. package/oiml-r91/entities/instrument.prl +359 -0
  299. package/oiml-r91/entities/workflow.prl +2075 -0
  300. package/oiml-r91/evaluation/processes.prl +152 -0
  301. package/oiml-r91/evaluation/workflow.prl +48 -0
  302. package/oiml-r91/execution/forms/evidence-file.prl +41 -0
  303. package/oiml-r91/execution/forms/report-evaluation/appraisal.prl +30 -0
  304. package/oiml-r91/execution/forms/report-evaluation/checklist-summary.prl +43 -0
  305. package/oiml-r91/execution/forms/report-evaluation/checklist.prl +76 -0
  306. package/oiml-r91/execution/forms/report-evaluation/configuration-samples.prl +22 -0
  307. package/oiml-r91/execution/forms/report-evaluation/corrective-actions.prl +24 -0
  308. package/oiml-r91/execution/forms/report-evaluation/descriptions.prl +47 -0
  309. package/oiml-r91/execution/forms/report-evaluation/evaluation-identification.prl +219 -0
  310. package/oiml-r91/execution/forms/report-evaluation/test-report-summary.prl +33 -0
  311. package/oiml-r91/execution/forms/report-general/adjustments.prl +12 -0
  312. package/oiml-r91/execution/forms/report-general/alignment-aiming.prl +17 -0
  313. package/oiml-r91/execution/forms/report-general/checking-facility.prl +17 -0
  314. package/oiml-r91/execution/forms/report-general/configuration.prl +12 -0
  315. package/oiml-r91/execution/forms/report-general/identification.prl +216 -0
  316. package/oiml-r91/execution/forms/report-general/indications-controls.prl +17 -0
  317. package/oiml-r91/execution/forms/report-general/sealing.prl +21 -0
  318. package/oiml-r91/execution/forms/report-general/software-description.prl +26 -0
  319. package/oiml-r91/execution/forms/report-general/summary-environmental.prl +35 -0
  320. package/oiml-r91/execution/forms/report-general/summary-tests.prl +35 -0
  321. package/oiml-r91/execution/forms/report-general/test-equipment.prl +36 -0
  322. package/oiml-r91/execution/forms/report-general/test-interface.prl +16 -0
  323. package/oiml-r91/execution/forms/report-tests/01-01-field-test.prl +84 -0
  324. package/oiml-r91/execution/forms/report-tests/01-02-statistical-analysis.prl +76 -0
  325. package/oiml-r91/execution/forms/report-tests/01-03-image-evidence.prl +30 -0
  326. package/oiml-r91/execution/forms/report-tests/02-01-dynamic-performance.prl +92 -0
  327. package/oiml-r91/execution/forms/report-tests/02-02-speed-linearity.prl +23 -0
  328. package/oiml-r91/execution/forms/report-tests/02-03-distance-linearity.prl +67 -0
  329. package/oiml-r91/execution/forms/report-tests/02-04-angle-linearity.prl +59 -0
  330. package/oiml-r91/execution/forms/report-tests/03-01-dry-heat-operating.prl +38 -0
  331. package/oiml-r91/execution/forms/report-tests/03-02-dry-heat-storage.prl +48 -0
  332. package/oiml-r91/execution/forms/report-tests/03-03-cold-operating.prl +40 -0
  333. package/oiml-r91/execution/forms/report-tests/03-04-cold-storage.prl +48 -0
  334. package/oiml-r91/execution/forms/report-tests/03-05-damp-heat-cyclic.prl +40 -0
  335. package/oiml-r91/execution/forms/report-tests/03-06-water.prl +48 -0
  336. package/oiml-r91/execution/forms/report-tests/03-07-sand-and-dust.prl +48 -0
  337. package/oiml-r91/execution/forms/report-tests/03-08-salt-mist.prl +48 -0
  338. package/oiml-r91/execution/forms/report-tests/03-09-vibration-random.prl +40 -0
  339. package/oiml-r91/execution/forms/report-tests/03-10-mechanical-shock.prl +48 -0
  340. package/oiml-r91/execution/forms/report-tests/03-11-dc-mains-voltage-variation.prl +40 -0
  341. package/oiml-r91/execution/forms/report-tests/03-12-ripple-on-dc-mains.prl +47 -0
  342. package/oiml-r91/execution/forms/report-tests/03-13-ac-mains-voltage-variation.prl +40 -0
  343. package/oiml-r91/execution/forms/report-tests/03-14-ac-mains-frequency-variation.prl +40 -0
  344. package/oiml-r91/execution/forms/report-tests/03-15-dc-mains-voltage-dips.prl +46 -0
  345. package/oiml-r91/execution/forms/report-tests/03-16-ac-mains-voltage-dips.prl +46 -0
  346. package/oiml-r91/execution/forms/report-tests/03-17-ac-mains-frequency-harmonics.prl +47 -0
  347. package/oiml-r91/execution/forms/report-tests/03-18-vlf-lf-disturbances.prl +46 -0
  348. package/oiml-r91/execution/forms/report-tests/03-19-bursts-ac-dc-mains.prl +44 -0
  349. package/oiml-r91/execution/forms/report-tests/03-20-surges-ac-dc-mains.prl +45 -0
  350. package/oiml-r91/execution/forms/report-tests/03-21-bursts-signal-lines.prl +45 -0
  351. package/oiml-r91/execution/forms/report-tests/03-22-surges-signal-lines.prl +46 -0
  352. package/oiml-r91/execution/forms/report-tests/03-23-ac-mains-magnetic-field.prl +45 -0
  353. package/oiml-r91/execution/forms/report-tests/03-24-conducted-rf-common-mode.prl +46 -0
  354. package/oiml-r91/execution/forms/report-tests/03-25-rf-electromagnetic-fields.prl +49 -0
  355. package/oiml-r91/execution/forms/report-tests/03-26-electrostatic-discharges.prl +47 -0
  356. package/oiml-r91/execution/forms/report-tests/03-27-internal-battery-low-voltage.prl +40 -0
  357. package/oiml-r91/execution/forms/report-tests/03-28-road-vehicle-battery.prl +40 -0
  358. package/oiml-r91/execution/forms/report-tests/03-29-transient-supply-lines.prl +47 -0
  359. package/oiml-r91/execution/forms/report-tests/03-30-transient-other-lines.prl +45 -0
  360. package/oiml-r91/execution/forms/report-tests/03-31-battery-cranking.prl +45 -0
  361. package/oiml-r91/execution/forms/report-tests/03-32-load-dump.prl +47 -0
  362. package/oiml-r91/execution/forms/report-tests/03-33-acceleration.prl +66 -0
  363. package/oiml-r91/execution/forms/report-tests/03-34-further-influence.prl +60 -0
  364. package/oiml-r91/execution/forms/report-tests/03-35-installation-alignment.prl +29 -0
  365. package/oiml-r91/execution/forms/report-tests/04-01-doppler-radar.prl +43 -0
  366. package/oiml-r91/execution/forms/report-tests/04-02-range-finding.prl +42 -0
  367. package/oiml-r91/execution/forms/report-tests/04-03-average-speed.prl +41 -0
  368. package/oiml-r91/execution/forms/report-tests/04-04-fixed-distance.prl +40 -0
  369. package/oiml-r91/execution/forms/report-tests/04-05-image-based.prl +41 -0
  370. package/oiml-r91/execution/forms/report-tests/04-06-across-road.prl +42 -0
  371. package/oiml-r91/execution/forms/report-tests/05-01-moving-field-test.prl +29 -0
  372. package/oiml-r91/execution/forms/report-tests/05-02-ego-field-test.prl +57 -0
  373. package/oiml-r91/execution/forms/report-tests/05-03-moving-traffic-simulation.prl +31 -0
  374. package/oiml-r91/execution/forms/report-tests/06-01-software-general.prl +25 -0
  375. package/oiml-r91/execution/forms/report-tests/06-02-software-protection.prl +25 -0
  376. package/oiml-r91/execution/forms/report-tests/06-03-software-hardware-support.prl +24 -0
  377. package/oiml-r91/execution/forms/report-tests/06-04-software-separation.prl +25 -0
  378. package/oiml-r91/execution/forms/report-tests/06-05-software-maintenance.prl +24 -0
  379. package/oiml-r91/execution/forms/report-tests/07-general-remarks.prl +11 -0
  380. package/oiml-r91/execution/forms/shared/header-a.prl +63 -0
  381. package/oiml-r91/execution/subforms/software-matrix-row.prl +30 -0
  382. package/oiml-r91/execution/subforms/speed-measurement-row.prl +38 -0
  383. package/oiml-r91/layers.prl +46 -0
  384. package/oiml-r91/model/artifacts.prl +29 -0
  385. package/oiml-r91/model/attributes.prl +698 -0
  386. package/oiml-r91/model/behaviors.prl +142 -0
  387. package/oiml-r91/model/capabilities.prl +88 -0
  388. package/oiml-r91/model/characteristics.prl +27 -0
  389. package/oiml-r91/model/conditions.prl +37 -0
  390. package/oiml-r91/model/instrument.prl +147 -0
  391. package/oiml-r91/model/state.prl +22 -0
  392. package/oiml-r91/model/twin.prl +17 -0
  393. package/oiml-r91/package.primmel +14 -0
  394. package/oiml-r91/payload/application.yaml +201 -0
  395. package/oiml-r91/payload/conditions-common-test.yaml +19 -0
  396. package/oiml-r91/payload/promises.yaml +142 -0
  397. package/oiml-r91/payload/sample-data.yaml +464 -0
  398. package/oiml-r91/references.prl +72 -0
  399. package/oiml-r91/sources-prd/coverage.json +106 -0
  400. package/oiml-r91/sources-prd/r91-1.sentences.json +4696 -0
  401. package/oiml-r91/sources-prd/r91-2.sentences.json +2067 -0
  402. package/oiml-r91/sources-prd/r91-3.sentences.json +5210 -0
  403. package/oiml-r91/sources-prd/r91-4.sentences.json +474 -0
  404. package/oiml-r91/specification/calculations.prl +26 -0
  405. package/oiml-r91/specification/conformance/influence-disturbance.prl +1792 -0
  406. package/oiml-r91/specification/conformance/metrological.prl +906 -0
  407. package/oiml-r91/specification/formulas.prl +10 -0
  408. package/oiml-r91/specification/requirements/class-specific.prl +308 -0
  409. package/oiml-r91/specification/requirements/metrological.prl +176 -0
  410. package/oiml-r91/specification/requirements/technical.prl +173 -0
  411. package/oiml-r91/specification/symbols.prl +323 -0
  412. package/oiml-r91/specification/tables.prl +136 -0
  413. package/oiml-r91/terminology.prl +535 -0
  414. package/oiml-r91/value-types.prl +26 -0
  415. package/oiml-smart-core/entities/comments.prl +101 -0
  416. package/oiml-smart-core/entities/cs-operations.prl +492 -0
  417. package/oiml-smart-core/entities/cs-participants.prl +470 -0
  418. package/oiml-smart-core/entities/engagement.prl +323 -0
  419. package/oiml-smart-core/entities/instrument.prl +359 -0
  420. package/oiml-smart-core/entities/module-b.prl +214 -0
  421. package/oiml-smart-core/entities/operated-schemes.prl +141 -0
  422. package/oiml-smart-core/entities/parties.prl +429 -0
  423. package/oiml-smart-core/entities/payment-records.prl +92 -0
  424. package/oiml-smart-core/entities/verification.prl +187 -0
  425. package/oiml-smart-core/entities/workflow.prl +2075 -0
  426. package/oiml-smart-core/evaluation/roles.prl +65 -0
  427. package/oiml-smart-core/evaluation/state-machines.prl +1157 -0
  428. package/oiml-smart-core/package.primmel +10 -0
  429. package/oiml-smart-core/specification/competence-kinds.prl +64 -0
  430. package/oiml-smart-core/specification/constraints.prl +40 -0
  431. package/oiml-smart-core/specification/invariants.prl +90 -0
  432. package/oiml-smart-core/specification/predicates.prl +116 -0
  433. package/oiml-smart-module-emc-disturbances/package.primmel +10 -0
  434. package/oiml-smart-module-env-iec60068/package.primmel +10 -0
  435. package/oiml-smart-module-examination-docs/package.primmel +10 -0
  436. package/oiml-smart-module-reference-materials/package.primmel +10 -0
  437. package/oiml-smart-module-report-headers/package.primmel +10 -0
  438. package/oiml-smart-module-software-d31/package.primmel +10 -0
  439. package/oiml-smart-module-specimen-governance/entities/test-execution.prl +228 -0
  440. package/oiml-smart-module-specimen-governance/package.primmel +10 -0
  441. package/oiml-twin-cert/documents/tw-1/document.yaml +454 -0
  442. package/oiml-twin-cert/evaluation/roles.prl +15 -0
  443. package/oiml-twin-cert/execution/forms/probe-creep.prl +179 -0
  444. package/oiml-twin-cert/execution/forms/probe.prl +99 -0
  445. package/oiml-twin-cert/execution/forms/static-conformance.prl +50 -0
  446. package/oiml-twin-cert/model/attributes.prl +243 -0
  447. package/oiml-twin-cert/model/behaviors.prl +8 -0
  448. package/oiml-twin-cert/model/characteristics.prl +18 -0
  449. package/oiml-twin-cert/model/monitors.prl +16 -0
  450. package/oiml-twin-cert/package.primmel +16 -0
  451. package/oiml-twin-cert/specification/conformance/twin-fidelity.prl +176 -0
  452. package/oiml-twin-cert/specification/requirements/twin-fidelity.prl +137 -0
  453. package/oiml-twin-cert/specification/symbols.prl +36 -0
  454. package/oiml-twin-cert/terminology.prl +8 -0
  455. package/oimlsmart-primmel-packages-0.1.0.tgz +0 -0
  456. package/package.json +17 -0
  457. package/qms-ref/model/qms.prl +31 -0
  458. package/qms-ref/package.primmel +38 -0
  459. package/quarry-belt-scale/model/ops.prl +115 -0
  460. package/quarry-belt-scale/package.primmel +36 -0
@@ -0,0 +1,48 @@
1
+ form r91-3/report-3-4 {
2
+ name "3.4 Cold (storage)"
3
+ description "R 91-3 test report, section 3.4 — the cold (storage) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFa No significant fault occurred after the disturbance. The EUT shall continue to operate as intended after the test (manual intervention allowed)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/cold-storage
7
+ section "R 91-3, p. 30"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-4-cold-storage"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-4-cold-storage/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-4"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-4"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-4/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-3"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field no_significant_fault : boolean {
22
+ label "No significant fault (NSFa)"
23
+ description "No significant fault occurred after the disturbance"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/disturbances }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field eut_operates_after : boolean {
31
+ label "EUT operates as intended after the test (manual intervention allowed)"
32
+ required true
33
+ measurement_method evaluated
34
+ targets { /req/metrological/disturbances }
35
+ true_label "Pass"
36
+ false_label "Fail"
37
+ }
38
+ field d11_reference : string {
39
+ label "Reference to OIML D 11:2013"
40
+ description "D 11 test-method reference recorded on the report form (clause 7)"
41
+ default "clause 7"
42
+ }
43
+ field remarks : text {
44
+
45
+ }
46
+ pass_fail { criteria "NSFa No significant fault occurred after the disturbance. The EUT shall continue to operate as intended after the test (manual intervention allowed)." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
47
+ }
48
+
@@ -0,0 +1,40 @@
1
+ form r91-3/report-3-5 {
2
+ name "3.5 Damp heat, cyclic (condensing)"
3
+ description "R 91-3 test report, section 3.5 — the damp heat, cyclic (condensing) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/influence/damp-heat-cyclic
7
+ section "R 91-3, p. 31"
8
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-5-damp-heat-cyclic-condensing"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-5-damp-heat-cyclic-condensing/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-5"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-5"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-5/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-4"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field evidence_files_intact : boolean {
22
+ label "Evidence files intact"
23
+ description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/linearity-limit }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field d11_reference : string {
31
+ label "Reference to OIML D 11:2013"
32
+ description "D 11 test-method reference recorded on the report form (clause 9)"
33
+ default "clause 9"
34
+ }
35
+ field remarks : text {
36
+
37
+ }
38
+ pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
39
+ }
40
+
@@ -0,0 +1,48 @@
1
+ form r91-3/report-3-6 {
2
+ name "3.6 Water (optional)"
3
+ description "R 91-3 test report, section 3.6 — the water (optional) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/water
7
+ section "R 91-3, p. 32"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-6-water-optional"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-6-water-optional/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-6"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-6"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-6/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-5"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field no_significant_fault : boolean {
22
+ label "No significant fault (NSFd)"
23
+ description "No significant fault occurred during the disturbance"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/disturbances }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field eut_operates_after : boolean {
31
+ label "EUT operates as intended after the test without manual intervention"
32
+ required true
33
+ measurement_method evaluated
34
+ targets { /req/metrological/disturbances }
35
+ true_label "Pass"
36
+ false_label "Fail"
37
+ }
38
+ field d11_reference : string {
39
+ label "Reference to OIML D 11:2013"
40
+ description "D 11 test-method reference recorded on the report form (clause 10)"
41
+ default "clause 10"
42
+ }
43
+ field remarks : text {
44
+
45
+ }
46
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
47
+ }
48
+
@@ -0,0 +1,48 @@
1
+ form r91-3/report-3-7 {
2
+ name "3.7 Sand and dust (optional)"
3
+ description "R 91-3 test report, section 3.7 — the sand and dust (optional) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/sand-and-dust
7
+ section "R 91-3, p. 33"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-7-sand-and-dust-optional"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-7-sand-and-dust-optional/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-7"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-7"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-7/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-6"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field no_significant_fault : boolean {
22
+ label "No significant fault (NSFd)"
23
+ description "No significant fault occurred during the disturbance"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/disturbances }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field eut_operates_after : boolean {
31
+ label "EUT operates as intended after the test without manual intervention"
32
+ required true
33
+ measurement_method evaluated
34
+ targets { /req/metrological/disturbances }
35
+ true_label "Pass"
36
+ false_label "Fail"
37
+ }
38
+ field d11_reference : string {
39
+ label "Reference to OIML D 11:2013"
40
+ description "D 11 test-method reference recorded on the report form (clause 13)"
41
+ default "clause 13"
42
+ }
43
+ field remarks : text {
44
+
45
+ }
46
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
47
+ }
48
+
@@ -0,0 +1,48 @@
1
+ form r91-3/report-3-8 {
2
+ name "3.8 Salt mist (optional)"
3
+ description "R 91-3 test report, section 3.8 — the salt mist (optional) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/salt-mist
7
+ section "R 91-3, p. 34"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-8-salt-mist-optional"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-8-salt-mist-optional/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-8"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-8"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-8/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-7"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field no_significant_fault : boolean {
22
+ label "No significant fault (NSFd)"
23
+ description "No significant fault occurred during the disturbance"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/disturbances }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field eut_operates_after : boolean {
31
+ label "EUT operates as intended after the test without manual intervention"
32
+ required true
33
+ measurement_method evaluated
34
+ targets { /req/metrological/disturbances }
35
+ true_label "Pass"
36
+ false_label "Fail"
37
+ }
38
+ field d11_reference : string {
39
+ label "Reference to OIML D 11:2013"
40
+ description "D 11 test-method reference recorded on the report form (clause 14)"
41
+ default "clause 14"
42
+ }
43
+ field remarks : text {
44
+
45
+ }
46
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
47
+ }
48
+
@@ -0,0 +1,40 @@
1
+ form r91-3/report-3-9 {
2
+ name "3.9 Vibration (random)"
3
+ description "R 91-3 test report, section 3.9 — the vibration (random) record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/influence/vibration-random
7
+ section "R 91-3, p. 35"
8
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-9-vibration-random"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-9-vibration-random/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-9"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-9"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-9/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-8"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field evidence_files_intact : boolean {
22
+ label "Evidence files intact"
23
+ description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/linearity-limit }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field d11_reference : string {
31
+ label "Reference to OIML D 11:2013"
32
+ description "D 11 test-method reference recorded on the report form (clause 15)"
33
+ default "clause 15"
34
+ }
35
+ field remarks : text {
36
+
37
+ }
38
+ pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
39
+ }
40
+
@@ -0,0 +1,48 @@
1
+ form r91-3/report-3-10 {
2
+ name "3.10 Mechanical shock"
3
+ description "R 91-3 test report, section 3.10 — the mechanical shock record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFa No significant fault occurred after the disturbance. The EUT shall continue to operate as intended after the test (manual intervention allowed)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/mechanical-shock
7
+ section "R 91-3, p. 36"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-10-mechanical-shock"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-10-mechanical-shock/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-10"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-10"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-10/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-9"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field no_significant_fault : boolean {
22
+ label "No significant fault (NSFa)"
23
+ description "No significant fault occurred after the disturbance"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/disturbances }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field eut_operates_after : boolean {
31
+ label "EUT operates as intended after the test (manual intervention allowed)"
32
+ required true
33
+ measurement_method evaluated
34
+ targets { /req/metrological/disturbances }
35
+ true_label "Pass"
36
+ false_label "Fail"
37
+ }
38
+ field d11_reference : string {
39
+ label "Reference to OIML D 11:2013"
40
+ description "D 11 test-method reference recorded on the report form (clause 17)"
41
+ default "clause 17"
42
+ }
43
+ field remarks : text {
44
+
45
+ }
46
+ pass_fail { criteria "NSFa No significant fault occurred after the disturbance. The EUT shall continue to operate as intended after the test (manual intervention allowed)." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
47
+ }
48
+
@@ -0,0 +1,40 @@
1
+ form r91-3/report-3-11 {
2
+ name "3.11 DC mains voltage variation"
3
+ description "R 91-3 test report, section 3.11 — the dc mains voltage variation record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/influence/dc-mains-voltage-variation
7
+ section "R 91-3, p. 37"
8
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-11-dc-mains-voltage-variation"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-11-dc-mains-voltage-variation/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-11"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-11"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-11/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-10"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field evidence_files_intact : boolean {
22
+ label "Evidence files intact"
23
+ description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/linearity-limit }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field d11_reference : string {
31
+ label "Reference to OIML D 11:2013"
32
+ description "D 11 test-method reference recorded on the report form (clause 18)"
33
+ default "clause 18"
34
+ }
35
+ field remarks : text {
36
+
37
+ }
38
+ pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
39
+ }
40
+
@@ -0,0 +1,47 @@
1
+ form r91-3/report-3-12 {
2
+ name "3.12 Ripple on DC mains power"
3
+ description "R 91-3 test report, section 3.12 — the ripple on dc mains power record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/ripple-on-dc-mains
7
+ section "R 91-3, p. 38"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-12-ripple-on-dc-mains-power"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-12-ripple-on-dc-mains-power/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-12"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-12/table-1"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-11"
14
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
15
+ field measurements : array {
16
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
17
+ required true
18
+ subform_ref speed-measurement-row { }
19
+ }
20
+ field no_significant_fault : boolean {
21
+ label "No significant fault (NSFd)"
22
+ description "No significant fault occurred during the disturbance"
23
+ required true
24
+ measurement_method evaluated
25
+ targets { /req/metrological/disturbances }
26
+ true_label "Pass"
27
+ false_label "Fail"
28
+ }
29
+ field eut_operates_after : boolean {
30
+ label "EUT operates as intended after the test without manual intervention"
31
+ required true
32
+ measurement_method evaluated
33
+ targets { /req/metrological/disturbances }
34
+ true_label "Pass"
35
+ false_label "Fail"
36
+ }
37
+ field d11_reference : string {
38
+ label "Reference to OIML D 11:2013"
39
+ description "D 11 test-method reference recorded on the report form (clause 19)"
40
+ default "clause 19"
41
+ }
42
+ field remarks : text {
43
+
44
+ }
45
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
46
+ }
47
+
@@ -0,0 +1,40 @@
1
+ form r91-3/report-3-13 {
2
+ name "3.13 AC mains voltage variation"
3
+ description "R 91-3 test report, section 3.13 — the ac mains voltage variation record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/influence/ac-mains-voltage-variation
7
+ section "R 91-3, p. 39"
8
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-13-ac-mains-voltage-variation"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-13-ac-mains-voltage-variation/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-13"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-12"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-12/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-12"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field evidence_files_intact : boolean {
22
+ label "Evidence files intact"
23
+ description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/linearity-limit }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field d11_reference : string {
31
+ label "Reference to OIML D 11:2013"
32
+ description "D 11 test-method reference recorded on the report form (clause 20)"
33
+ default "clause 20"
34
+ }
35
+ field remarks : text {
36
+
37
+ }
38
+ pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
39
+ }
40
+
@@ -0,0 +1,40 @@
1
+ form r91-3/report-3-14 {
2
+ name "3.14 AC mains frequency variation"
3
+ description "R 91-3 test report, section 3.14 — the ac mains frequency variation record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/influence/ac-mains-frequency-variation
7
+ section "R 91-3, p. 40"
8
+ requirements { /req/metrological/linearity-limit /req/metrological/influence-quantities }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-14-ac-mains-frequency-variation"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-14-ac-mains-frequency-variation/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-14"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-13"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-results-13/table-1"
14
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-13"
15
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
16
+ field measurements : array {
17
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
18
+ required true
19
+ subform_ref speed-measurement-row { }
20
+ }
21
+ field evidence_files_intact : boolean {
22
+ label "Evidence files intact"
23
+ description "The evidence files produced for every measurement are not corrupt and the photographic documentation is of the same quality as without the influence factor (if camera is part of EUT)"
24
+ required true
25
+ measurement_method evaluated
26
+ targets { /req/metrological/linearity-limit }
27
+ true_label "Pass"
28
+ false_label "Fail"
29
+ }
30
+ field d11_reference : string {
31
+ label "Reference to OIML D 11:2013"
32
+ description "D 11 test-method reference recorded on the report form (clause 21)"
33
+ default "clause 21"
34
+ }
35
+ field remarks : text {
36
+
37
+ }
38
+ pass_fail { criteria "MPE Linearity error limit defined in OIML R 91-1, 6.5 is respected during the presence of the influence factor. The evidence files produced for every measurement must not be corrupt and the photographic documentation must be of the same quality as without the influence factor (if camera is part of EUT)." pass_if "ocl{measurements->forAll(m | m.row_passed) and evidence_files_intact}" }
39
+ }
40
+
@@ -0,0 +1,46 @@
1
+ form r91-3/report-3-15 {
2
+ name "3.15 DC mains voltage dips, short interruptions and (short term) voltage variations"
3
+ description "R 91-3 test report, section 3.15 — the dc mains voltage dips, short interruptions and (short term) voltage variations record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/dc-mains-voltage-dips
7
+ section "R 91-3, p. 41"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-15-dc-mains-voltage-dips-short-interruptions-and-short-term-voltage-variations"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-15-dc-mains-voltage-dips-short-interruptions-and-short-term-voltage-variations/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-15-dc-mains-voltage-dips-short-interruptions-and-short-term-voltage-variations/table-2"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-14"
13
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
14
+ field measurements : array {
15
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
16
+ required true
17
+ subform_ref speed-measurement-row { }
18
+ }
19
+ field no_significant_fault : boolean {
20
+ label "No significant fault (NSFd)"
21
+ description "No significant fault occurred during the disturbance"
22
+ required true
23
+ measurement_method evaluated
24
+ targets { /req/metrological/disturbances }
25
+ true_label "Pass"
26
+ false_label "Fail"
27
+ }
28
+ field eut_operates_after : boolean {
29
+ label "EUT operates as intended after the test without manual intervention"
30
+ required true
31
+ measurement_method evaluated
32
+ targets { /req/metrological/disturbances }
33
+ true_label "Pass"
34
+ false_label "Fail"
35
+ }
36
+ field d11_reference : string {
37
+ label "Reference to OIML D 11:2013"
38
+ description "D 11 test-method reference recorded on the report form (clause 22)"
39
+ default "clause 22"
40
+ }
41
+ field remarks : text {
42
+
43
+ }
44
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
45
+ }
46
+
@@ -0,0 +1,46 @@
1
+ form r91-3/report-3-16 {
2
+ name "3.16 AC mains voltage dips, short interruptions and reductions"
3
+ description "R 91-3 test report, section 3.16 — the ac mains voltage dips, short interruptions and reductions record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/ac-mains-voltage-dips
7
+ section "R 91-3, p. 42"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-16-ac-mains-voltage-dips-short-interruptions-and-reductions"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-16-ac-mains-voltage-dips-short-interruptions-and-reductions/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-15"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-15/table-1"
13
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
14
+ field measurements : array {
15
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
16
+ required true
17
+ subform_ref speed-measurement-row { }
18
+ }
19
+ field no_significant_fault : boolean {
20
+ label "No significant fault (NSFd)"
21
+ description "No significant fault occurred during the disturbance"
22
+ required true
23
+ measurement_method evaluated
24
+ targets { /req/metrological/disturbances }
25
+ true_label "Pass"
26
+ false_label "Fail"
27
+ }
28
+ field eut_operates_after : boolean {
29
+ label "EUT operates as intended after the test without manual intervention"
30
+ required true
31
+ measurement_method evaluated
32
+ targets { /req/metrological/disturbances }
33
+ true_label "Pass"
34
+ false_label "Fail"
35
+ }
36
+ field d11_reference : string {
37
+ label "Reference to OIML D 11:2013"
38
+ description "D 11 test-method reference recorded on the report form (clause 23)"
39
+ default "clause 23"
40
+ }
41
+ field remarks : text {
42
+
43
+ }
44
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
45
+ }
46
+
@@ -0,0 +1,47 @@
1
+ form r91-3/report-3-17 {
2
+ name "3.17 AC mains frequency harmonics"
3
+ description "R 91-3 test report, section 3.17 — the ac mains frequency harmonics record (procedure per OIML R 91-2, clause 6 / 6.1 Tables 1–2). Acceptance criterion: NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention."
4
+ data_class FormInstance#data
5
+ header r91-3/header-a
6
+ conformance_process /conf/disturbances/ac-mains-frequency-harmonics
7
+ section "R 91-3, p. 43"
8
+ requirements { /req/metrological/disturbances }
9
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-17-ac-mains-frequency-harmonics"
10
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-3-17-ac-mains-frequency-harmonics/table-1"
11
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-16"
12
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-acceptance-criterion-16/table-1"
13
+ ref report-format "urn:oiml:pub:r:91-3:2025#clause-remarks-15"
14
+ ref test-procedure "urn:oiml:pub:r:91-2:2025#clause-6.1"
15
+ field measurements : array {
16
+ description "Results-table rows (Measurement No. | v | vref | Δv | MPE | Pass | Fail)"
17
+ required true
18
+ subform_ref speed-measurement-row { }
19
+ }
20
+ field no_significant_fault : boolean {
21
+ label "No significant fault (NSFd)"
22
+ description "No significant fault occurred during the disturbance"
23
+ required true
24
+ measurement_method evaluated
25
+ targets { /req/metrological/disturbances }
26
+ true_label "Pass"
27
+ false_label "Fail"
28
+ }
29
+ field eut_operates_after : boolean {
30
+ label "EUT operates as intended after the test without manual intervention"
31
+ required true
32
+ measurement_method evaluated
33
+ targets { /req/metrological/disturbances }
34
+ true_label "Pass"
35
+ false_label "Fail"
36
+ }
37
+ field d11_reference : string {
38
+ label "Reference to OIML D 11:2013"
39
+ description "D 11 test-method reference recorded on the report form (clause 24)"
40
+ default "clause 24"
41
+ }
42
+ field remarks : text {
43
+
44
+ }
45
+ pass_fail { criteria "NSFd No significant fault occurred during the disturbance. The EUT shall continue to operate as intended after the test without manual intervention." pass_if "ocl{measurements->forAll(m | m.row_passed) and no_significant_fault and eut_operates_after}" }
46
+ }
47
+