@zwave-js/config 8.9.2 → 8.10.1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- package/config/devices/0x000c/hs-wd200.json +19 -17
- package/config/devices/0x000c/hs-wx300.json +46 -73
- package/config/devices/0x000c/templates/homeseer_template.json +32 -0
- package/config/devices/0x001a/rf9640.json +59 -73
- package/config/devices/0x003b/jbe109.json +29 -52
- package/config/devices/0x003b/jfe109.json +133 -0
- package/config/devices/0x003b/s-6500f.json +13 -13
- package/config/devices/0x0060/an301.json +17 -0
- package/config/devices/0x0063/39348_54890_54891_zw4008.json +2 -2
- package/config/devices/0x0063/39354_54912_zw4009.json +2 -2
- package/config/devices/0x0063/43072_zw4008dv.json +5 -5
- package/config/devices/0x0063/43074_zw4009dv.json +5 -5
- package/config/devices/0x0063/43105_zw3014.json +2 -2
- package/config/devices/0x0063/43107_zw3015.json +2 -2
- package/config/devices/0x0063/46201.json +3 -2
- package/config/devices/0x0063/46202.json +23 -2
- package/config/devices/0x0063/46562_zw4008.json +2 -2
- package/config/devices/0x0063/52190_zw7105.json +12 -5
- package/config/devices/0x0063/56590_56592_zw3012.json +200 -0
- package/config/devices/0x0063/64637_zw7105.json +50 -0
- package/config/devices/0x0086/templates/aeotec_template.json +23 -14
- package/config/devices/0x0090/{893.json → hc620.json} +13 -8
- package/config/devices/0x0094/2gig-edg-n.json +28 -0
- package/config/devices/0x0094/adc-sg130z.json +28 -0
- package/config/devices/0x0094/tboost-a_2.json +27 -0
- package/config/devices/0x0094/tboost-t_2.json +27 -0
- package/config/devices/0x009b/2gig-stz.json +1 -1
- package/config/devices/0x0109/za1021-7.json +27 -0
- package/config/devices/0x0109/zp3113-7.json +135 -0
- package/config/devices/0x010e/danalock_v3-btze.json +37 -21
- package/config/devices/0x010f/fgbs222.json +239 -185
- package/config/devices/0x010f/fghc3-001.json +27 -0
- package/config/devices/0x010f/fgt001.json +0 -1
- package/config/devices/0x010f/fgwdeu.json +28 -39
- package/config/devices/0x010f/hc3l-001.json +27 -0
- package/config/devices/0x010f/yh-001.json +27 -0
- package/config/devices/0x0112/itb-5104.json +27 -0
- package/config/devices/0x0129/templates/yale_template.json +15 -0
- package/config/devices/0x0129/yrc216-zw3.json +245 -0
- package/config/devices/0x0129/yrc226-zw3.json +76 -0
- package/config/devices/0x0129/yrc256-zw3.json +76 -0
- package/config/devices/0x0129/yrd216-zw3.json +76 -0
- package/config/devices/0x0129/yrd226-zw3.json +76 -0
- package/config/devices/0x012a/iq_dimmer.json +80 -0
- package/config/devices/0x012a/iq_outlet.json +76 -0
- package/config/devices/0x012a/qs9201-1208-840.json +12 -0
- package/config/devices/0x0138/smco400.json +61 -0
- package/config/devices/0x013c/pad15.json +12 -38
- package/config/devices/0x013c/pan30.json +160 -0
- package/config/devices/0x013c/pan34.json +124 -0
- package/config/devices/0x013c/pse04.json +162 -0
- package/config/devices/0x0140/sc428zw.json +177 -0
- package/config/devices/0x0149/wds2.json +34 -1
- package/config/devices/0x014a/tilt-zwave5.json +92 -0
- package/config/devices/0x014a/tstat-tbz500.json +66 -61
- package/config/devices/0x014f/el-sc-100.json +4 -4
- package/config/devices/0x0156/m_n_kp01.json +108 -0
- package/config/devices/0x0159/zmnhhd.json +162 -69
- package/config/devices/0x0159/zmnkad1.json +204 -0
- package/config/devices/0x0166/sw-zcs-1.json +5 -1
- package/config/devices/0x0189/117001.json +227 -0
- package/config/devices/0x0194/clr-c1-pnlx.json +28 -0
- package/config/devices/0x019a/11_01_022.json +30 -25
- package/config/devices/0x019a/11_02_022.json +320 -0
- package/config/devices/0x019a/11_04_21_22_28.json +210 -0
- package/config/devices/0x019b/z-ph_wall_controller.json +113 -0
- package/config/devices/0x019b/zm_thermostat_16.json +159 -0
- package/config/devices/0x021d/ml2.json +120 -0
- package/config/devices/0x0234/zdb5100.json +4 -0
- package/config/devices/0x0244/homey.json +2 -2
- package/config/devices/0x0258/nas-pd07u1.json +0 -1
- package/config/devices/0x0258/nas-wr01ze.json +7 -1
- package/config/devices/0x0258/neo-ds07z.json +156 -0
- package/config/devices/0x025b/ezlopl.json +28 -0
- package/config/devices/0x025b/ezlosecure.json +28 -0
- package/config/devices/0x027a/zen17.json +11 -0
- package/config/devices/0x027a/zen32.json +12 -1
- package/config/devices/0x027a/zen34.json +11 -4
- package/config/devices/0x027a/zen71.json +9 -2
- package/config/devices/0x027a/zen72.json +9 -2
- package/config/devices/0x027a/zen76.json +9 -2
- package/config/devices/0x027a/zen77.json +9 -2
- package/config/devices/0x027a/zse40.json +20 -2
- package/config/devices/0x027a/zse43.json +212 -0
- package/config/devices/0x027a/zse44.json +365 -0
- package/config/devices/0x028c/pwly-7828-a1.json +289 -0
- package/config/devices/0x0300/7aa-ss-ve-a0.json +117 -0
- package/config/devices/0x0300/7ba-kp-v-b-a0.json +105 -0
- package/config/devices/0x0300/7ca-ss-ve-a0.json +110 -0
- package/config/devices/0x0312/mp21zd.json +40 -122
- package/config/devices/0x0312/mp21zp.json +24 -48
- package/config/devices/0x0312/mp22z.json +62 -52
- package/config/devices/0x0312/mr40z.json +55 -0
- package/config/devices/0x0312/ms10z.json +45 -185
- package/config/devices/0x0312/ms11zs.json +107 -0
- package/config/devices/0x0312/ms12z.json +45 -185
- package/config/devices/0x0312/ms13z.json +61 -256
- package/config/devices/0x0312/mse30z.json +216 -0
- package/config/devices/0x0312/n4001.json +50 -0
- package/config/devices/0x0312/n4002.json +108 -0
- package/config/devices/0x0312/templates/minoston_template.json +276 -0
- package/config/devices/0x0312/zw1103.json +1 -1
- package/config/devices/0x0312/zw1105.json +1 -1
- package/config/devices/0x0312/zw1201.json +1 -1
- package/config/devices/0x0312/zw1204.json +1 -1
- package/config/devices/0x0312/zw15.json +1 -1
- package/config/devices/0x0312/zw31.json +1 -1
- package/config/devices/0x0312/zw31s.json +109 -0
- package/config/devices/0x0312/zw32.json +1 -1
- package/config/devices/0x0312/zw37.json +1 -1
- package/config/devices/0x0312/zw39.json +211 -1
- package/config/devices/0x0312/zw681.json +1 -1
- package/config/devices/0x0312/zw922.json +70 -0
- package/config/devices/0x0312/zw96.json +1 -1
- package/config/devices/0x0312/zw97.json +1 -1
- package/config/devices/0x031e/lzw30-sn.json +9 -2
- package/config/devices/0x031e/lzw31-sn.json +9 -2
- package/config/devices/0x0330/sr-zv9001t4-dim.json +4 -0
- package/config/devices/0x0330/sr-zv9021a.json +201 -0
- package/config/devices/0x0330/sr-zv9092a.json +423 -0
- package/config/devices/0x0344/he-tps01.json +6 -1
- package/config/devices/0x0344/he-tps02.json +12 -2
- package/config/devices/0x0344/he-tps03.json +18 -13
- package/config/devices/0x0344/he-tps04.json +24 -4
- package/config/devices/0x0344/he-tps05.json +31 -6
- package/config/devices/0x0344/templates/heltun_template.json +57 -0
- package/config/devices/0x0346/contact_sensor_gen2.json +1 -1
- package/config/devices/0x0346/keypad_v2.json +7 -7
- package/config/devices/0x0346/motion_sensor_gen2.json +7 -3
- package/config/devices/0x0346/outdoor_contact_sensor.json +106 -0
- package/config/devices/0x0346/range_extender_gen2.json +6 -2
- package/config/devices/0x0346/ring_base_station.json +5 -5
- package/config/devices/0x0346/ring_outdoor_siren.json +5 -1
- package/config/devices/0x0367/svhszwb1.json +13 -6
- package/config/devices/0x0371/zwa022.json +175 -0
- package/config/devices/0x0371/zwa024.json +831 -0
- package/config/devices/0x0390/ah-hub3.json +28 -0
- package/config/devices/0x039a/INT-SMDWD-01.json +99 -0
- package/config/devices/0x041b/39455_zw4008.json +6 -22
- package/config/devices/0x0445/trf-zw10.json +28 -0
- package/config/devices/0x0447/sqr14101_z.json +2 -18
- package/config/devices/0x0447/sqr14102_z.json +52 -0
- package/config/devices/0x0447/sqr22101_z.json +2 -18
- package/config/devices/0x0447/sqr22102_z.json +74 -0
- package/config/devices/0x0447/sqr44101_z.json +2 -18
- package/config/devices/0x0447/sqr44102_z.json +52 -0
- package/config/devices/0x0447/sqr50101_z.json +44 -0
- package/config/devices/0x0447/sqr62101whz.json +1 -17
- package/config/devices/0x0447/sqr62102whz.json +52 -0
- package/config/devices/0x0447/templates/schneider_template.json +15 -0
- package/config/devices/0x044f/uvh1301.json +30 -0
- package/config/devices/0x0450/h3ps-wc1.json +28 -0
- package/config/devices/0x0452/u-bolt-pro-zwave.json +30 -0
- package/config/devices/0x0454/v11-n13.json +30 -0
- package/config/devices/0x0456/homee-005.json +28 -0
- package/config/devices/0x4118/tsm02.json +122 -0
- package/config/devices/templates/master_template.json +93 -5
- package/package.json +10 -10
- package/config/devices/0x0090/892.json +0 -170
- package/config/devices/0x019a/11_04_022.json +0 -230
- package/config/devices/0x0312/nzw39.json +0 -215
|
@@ -1,16 +1,226 @@
|
|
|
1
1
|
{
|
|
2
|
-
"manufacturer": "
|
|
2
|
+
"manufacturer": "EVA Logik",
|
|
3
3
|
"manufacturerId": "0x0312",
|
|
4
4
|
"label": "ZW39",
|
|
5
5
|
"description": "Dimmable Smart Plug",
|
|
6
6
|
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x2700",
|
|
9
|
+
"productId": "0x2700"
|
|
10
|
+
},
|
|
7
11
|
{
|
|
8
12
|
"productType": "0xc000",
|
|
9
13
|
"productId": "0xc002"
|
|
14
|
+
},
|
|
15
|
+
{
|
|
16
|
+
"productType": "0xb212",
|
|
17
|
+
"productId": "0x271c",
|
|
18
|
+
"zwaveAllianceId": 2358
|
|
10
19
|
}
|
|
11
20
|
],
|
|
12
21
|
"firmwareVersion": {
|
|
13
22
|
"min": "0.0",
|
|
14
23
|
"max": "255.255"
|
|
24
|
+
},
|
|
25
|
+
"paramInformation": [
|
|
26
|
+
{
|
|
27
|
+
"#": "1",
|
|
28
|
+
"label": "Dimming Step",
|
|
29
|
+
"description": "Percentage of step when switch is dimming up or down (0 = instant)",
|
|
30
|
+
"valueSize": 1,
|
|
31
|
+
"minValue": 0,
|
|
32
|
+
"maxValue": 99,
|
|
33
|
+
"defaultValue": 0
|
|
34
|
+
},
|
|
35
|
+
{
|
|
36
|
+
"#": "2",
|
|
37
|
+
"label": "Minimum Level",
|
|
38
|
+
"description": "Minimum dimming level for attached light",
|
|
39
|
+
"valueSize": 1,
|
|
40
|
+
"minValue": 1,
|
|
41
|
+
"maxValue": 99,
|
|
42
|
+
"defaultValue": 1
|
|
43
|
+
},
|
|
44
|
+
{
|
|
45
|
+
"#": "3",
|
|
46
|
+
"label": "LED Indicator",
|
|
47
|
+
"description": "Turn LED indicator ON when light is ON (paddle switch only)",
|
|
48
|
+
"valueSize": 1,
|
|
49
|
+
"minValue": 0,
|
|
50
|
+
"maxValue": 3,
|
|
51
|
+
"defaultValue": 1,
|
|
52
|
+
"allowManualEntry": false,
|
|
53
|
+
"options": [
|
|
54
|
+
{
|
|
55
|
+
"label": "OFF",
|
|
56
|
+
"value": 0
|
|
57
|
+
},
|
|
58
|
+
{
|
|
59
|
+
"label": "ON",
|
|
60
|
+
"value": 1
|
|
61
|
+
},
|
|
62
|
+
{
|
|
63
|
+
"label": "Disabled",
|
|
64
|
+
"value": 2
|
|
65
|
+
},
|
|
66
|
+
{
|
|
67
|
+
"label": "Always ON",
|
|
68
|
+
"value": 3
|
|
69
|
+
}
|
|
70
|
+
]
|
|
71
|
+
},
|
|
72
|
+
{
|
|
73
|
+
"#": "4",
|
|
74
|
+
"label": "Invert Switch",
|
|
75
|
+
"description": "Invert on & off on the physical switch",
|
|
76
|
+
"valueSize": 1,
|
|
77
|
+
"minValue": 0,
|
|
78
|
+
"maxValue": 1,
|
|
79
|
+
"defaultValue": 0,
|
|
80
|
+
"allowManualEntry": false,
|
|
81
|
+
"options": [
|
|
82
|
+
{
|
|
83
|
+
"label": "Disable",
|
|
84
|
+
"value": 0
|
|
85
|
+
},
|
|
86
|
+
{
|
|
87
|
+
"label": "Enable",
|
|
88
|
+
"value": 1
|
|
89
|
+
}
|
|
90
|
+
]
|
|
91
|
+
},
|
|
92
|
+
{
|
|
93
|
+
"#": "5",
|
|
94
|
+
"label": "Auto Off Timer",
|
|
95
|
+
"valueSize": 2,
|
|
96
|
+
"unit": "seconds",
|
|
97
|
+
"minValue": 0,
|
|
98
|
+
"maxValue": 32767,
|
|
99
|
+
"defaultValue": 0
|
|
100
|
+
},
|
|
101
|
+
{
|
|
102
|
+
"#": "7",
|
|
103
|
+
"label": "Association Group 3 Setting",
|
|
104
|
+
"description": "Change how devices respond when associated in group 3",
|
|
105
|
+
"valueSize": 1,
|
|
106
|
+
"minValue": 0,
|
|
107
|
+
"maxValue": 1,
|
|
108
|
+
"defaultValue": 0,
|
|
109
|
+
"allowManualEntry": false,
|
|
110
|
+
"options": [
|
|
111
|
+
{
|
|
112
|
+
"label": "Dim up/down",
|
|
113
|
+
"value": 0
|
|
114
|
+
},
|
|
115
|
+
{
|
|
116
|
+
"label": "Keep in sync",
|
|
117
|
+
"value": 1
|
|
118
|
+
}
|
|
119
|
+
]
|
|
120
|
+
},
|
|
121
|
+
{
|
|
122
|
+
"#": "8",
|
|
123
|
+
"label": "Default Level (local)",
|
|
124
|
+
"description": "Default level when light is turned on at the switch (0 = previous level)",
|
|
125
|
+
"valueSize": 1,
|
|
126
|
+
"minValue": 0,
|
|
127
|
+
"maxValue": 99,
|
|
128
|
+
"defaultValue": 0
|
|
129
|
+
},
|
|
130
|
+
{
|
|
131
|
+
"#": "9",
|
|
132
|
+
"label": "Default Level (Z-Wave)",
|
|
133
|
+
"description": "Default level when light is turned on via Z-Wave command (0 = previous level)",
|
|
134
|
+
"valueSize": 1,
|
|
135
|
+
"minValue": 0,
|
|
136
|
+
"maxValue": 99,
|
|
137
|
+
"defaultValue": 0
|
|
138
|
+
},
|
|
139
|
+
{
|
|
140
|
+
"#": "6[0x01]",
|
|
141
|
+
"label": "Send command on local action",
|
|
142
|
+
"description": "When should the switch send commands to Group 3 devices?",
|
|
143
|
+
"valueSize": 1,
|
|
144
|
+
"minValue": 0,
|
|
145
|
+
"maxValue": 1,
|
|
146
|
+
"defaultValue": 1,
|
|
147
|
+
"allowManualEntry": false,
|
|
148
|
+
"options": [
|
|
149
|
+
{
|
|
150
|
+
"label": "Disable",
|
|
151
|
+
"value": 0
|
|
152
|
+
},
|
|
153
|
+
{
|
|
154
|
+
"label": "Enable",
|
|
155
|
+
"value": 1
|
|
156
|
+
}
|
|
157
|
+
]
|
|
158
|
+
},
|
|
159
|
+
{
|
|
160
|
+
"#": "6[0x02]",
|
|
161
|
+
"label": "Send command on 3-way action",
|
|
162
|
+
"description": "When should the switch send commands to Group 3 devices?",
|
|
163
|
+
"valueSize": 1,
|
|
164
|
+
"minValue": 0,
|
|
165
|
+
"maxValue": 1,
|
|
166
|
+
"defaultValue": 0,
|
|
167
|
+
"allowManualEntry": false,
|
|
168
|
+
"options": [
|
|
169
|
+
{
|
|
170
|
+
"label": "Disable",
|
|
171
|
+
"value": 0
|
|
172
|
+
},
|
|
173
|
+
{
|
|
174
|
+
"label": "Enable",
|
|
175
|
+
"value": 1
|
|
176
|
+
}
|
|
177
|
+
]
|
|
178
|
+
},
|
|
179
|
+
{
|
|
180
|
+
"#": "6[0x04]",
|
|
181
|
+
"label": "Send command on z-wave action",
|
|
182
|
+
"description": "When should the switch send commands to Group 3 devices?",
|
|
183
|
+
"valueSize": 1,
|
|
184
|
+
"minValue": 0,
|
|
185
|
+
"maxValue": 1,
|
|
186
|
+
"defaultValue": 0,
|
|
187
|
+
"allowManualEntry": false,
|
|
188
|
+
"options": [
|
|
189
|
+
{
|
|
190
|
+
"label": "Disable",
|
|
191
|
+
"value": 0
|
|
192
|
+
},
|
|
193
|
+
{
|
|
194
|
+
"label": "Enable",
|
|
195
|
+
"value": 1
|
|
196
|
+
}
|
|
197
|
+
]
|
|
198
|
+
},
|
|
199
|
+
{
|
|
200
|
+
"#": "6[0x08]",
|
|
201
|
+
"label": "Send command on auto off timer",
|
|
202
|
+
"description": "When should the switch send commands to Group 3 devices?",
|
|
203
|
+
"valueSize": 1,
|
|
204
|
+
"minValue": 0,
|
|
205
|
+
"maxValue": 1,
|
|
206
|
+
"defaultValue": 0,
|
|
207
|
+
"allowManualEntry": false,
|
|
208
|
+
"options": [
|
|
209
|
+
{
|
|
210
|
+
"label": "Disable",
|
|
211
|
+
"value": 0
|
|
212
|
+
},
|
|
213
|
+
{
|
|
214
|
+
"label": "Enable",
|
|
215
|
+
"value": 1
|
|
216
|
+
}
|
|
217
|
+
]
|
|
218
|
+
}
|
|
219
|
+
],
|
|
220
|
+
"metadata": {
|
|
221
|
+
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.\n2. Once the controller is ready to include your device, press up and release the toggle to include it in the network.\n3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance.\n4. The device is associated in the same group when it included in setting process. \nNow you can control your Z-Wave device according to groups, scenes, schedules and automation programmed.",
|
|
222
|
+
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.\n2. Once the controller is ready to Exclude your device, press up and release the front button to exclude it from the network.",
|
|
223
|
+
"reset": "1. Press and hold the top button for at least 3 seconds while you plug the smart switch into a receptacle.\n2. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.",
|
|
224
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2358/ZW39manual170412.pdf"
|
|
15
225
|
}
|
|
16
226
|
}
|
|
@@ -0,0 +1,70 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "EVA Logik",
|
|
3
|
+
"manufacturerId": "0x0312",
|
|
4
|
+
"label": "ZW922",
|
|
5
|
+
"description": "S2 Remote Control Switch",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x7000",
|
|
9
|
+
"productId": "0xf001",
|
|
10
|
+
"zwaveAllianceId": 4080
|
|
11
|
+
}
|
|
12
|
+
],
|
|
13
|
+
"firmwareVersion": {
|
|
14
|
+
"min": "0.0",
|
|
15
|
+
"max": "255.255"
|
|
16
|
+
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 1,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
},
|
|
23
|
+
"2": {
|
|
24
|
+
"label": "Single Press",
|
|
25
|
+
"maxNodes": 5
|
|
26
|
+
},
|
|
27
|
+
"3": {
|
|
28
|
+
"label": "Hold button",
|
|
29
|
+
"maxNodes": 5
|
|
30
|
+
}
|
|
31
|
+
},
|
|
32
|
+
"paramInformation": [
|
|
33
|
+
{
|
|
34
|
+
"#": "1",
|
|
35
|
+
"$import": "~/templates/master_template.json#led_indicator_four_options",
|
|
36
|
+
"options": [
|
|
37
|
+
{
|
|
38
|
+
"label": "Always off",
|
|
39
|
+
"value": 0
|
|
40
|
+
},
|
|
41
|
+
{
|
|
42
|
+
"label": "On at 100% brightness",
|
|
43
|
+
"value": 1
|
|
44
|
+
},
|
|
45
|
+
{
|
|
46
|
+
"label": "Always on - color per parameter 2",
|
|
47
|
+
"value": 2
|
|
48
|
+
},
|
|
49
|
+
{
|
|
50
|
+
"label": "Always on - color per parameter 3",
|
|
51
|
+
"value": 3
|
|
52
|
+
}
|
|
53
|
+
]
|
|
54
|
+
},
|
|
55
|
+
{
|
|
56
|
+
"#": "2",
|
|
57
|
+
"$import": "~/0x0312/templates/minoston_template.json#led_indicator_color_upper"
|
|
58
|
+
},
|
|
59
|
+
{
|
|
60
|
+
"#": "3",
|
|
61
|
+
"$import": "~/0x0312/templates/minoston_template.json#led_indicator_color_lower"
|
|
62
|
+
}
|
|
63
|
+
],
|
|
64
|
+
"metadata": {
|
|
65
|
+
"inclusion": "1. Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.\n2. When prompted by your primary controller, click the Up or Down button six times in one second.\nThe device is compatible with SmartStart\nSmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code found on the top of the outlet or the back of\nthe box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within\n10 minutes of being switched on and in the network vicinity",
|
|
66
|
+
"exclusion": "1. Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.\n2. When prompted by your primary controller, click the Up or Down button six times in one second.\nThe device is compatible with SmartStart\nSmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code found on the top of the outlet or the back of\nthe box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within\n10 minutes of being switched on and in the network vicinity",
|
|
67
|
+
"reset": "Tap-tap-tap’and’hold to reset, LED indicator will blink red 5 times to confirm successful reset",
|
|
68
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4080/ZW922-manual-20210118.pdf"
|
|
69
|
+
}
|
|
70
|
+
}
|
|
@@ -6,7 +6,8 @@
|
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x0002",
|
|
9
|
-
"productId": "0x0001"
|
|
9
|
+
"productId": "0x0001",
|
|
10
|
+
"zwaveAllianceId": 4197
|
|
10
11
|
}
|
|
11
12
|
],
|
|
12
13
|
"firmwareVersion": {
|
|
@@ -493,5 +494,11 @@
|
|
|
493
494
|
}
|
|
494
495
|
]
|
|
495
496
|
}
|
|
496
|
-
]
|
|
497
|
+
],
|
|
498
|
+
"metadata": {
|
|
499
|
+
"inclusion": "To include your on/off switch start the inclusion process on your HUB and tap the Configuration Button three (3) times.\n\nPlease Note: If this doesn't work, you can check to see if your switch is within Z-Wave Range by holding down the Configuration Button for 5-10 seconds (if it's not within range, the LED Bar will indicate Red and if it is within Range, the LED Bar will indicate Green). If your switch indicates Red, please move the switch closer to the HUB. If your switch indicates Green, please try running an Exclusion to reset your switch",
|
|
500
|
+
"exclusion": "To Exclude your switch, put your HUB in exclusion mode and press the Configuration Button three (3) times",
|
|
501
|
+
"reset": "You may factory reset the switch by holding down the Config Button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. \n\nHowever, we recommend using a certified Z-Wave controller to remove the device from your network for factory resetting the switch. \n\nOnly use either of these procedures in the event that the network primary controller is missing or otherwise inoperable",
|
|
502
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4197/LZW30-SN%20Manual%20-%20Inovelli%20On-Off%20Switch%20(Red%20Series)%20-%2006.28.21.pdf"
|
|
503
|
+
}
|
|
497
504
|
}
|
|
@@ -6,7 +6,8 @@
|
|
|
6
6
|
"devices": [
|
|
7
7
|
{
|
|
8
8
|
"productType": "0x0001",
|
|
9
|
-
"productId": "0x0001"
|
|
9
|
+
"productId": "0x0001",
|
|
10
|
+
"zwaveAllianceId": 4206
|
|
10
11
|
}
|
|
11
12
|
],
|
|
12
13
|
"firmwareVersion": {
|
|
@@ -717,5 +718,11 @@
|
|
|
717
718
|
}
|
|
718
719
|
]
|
|
719
720
|
}
|
|
720
|
-
]
|
|
721
|
+
],
|
|
722
|
+
"metadata": {
|
|
723
|
+
"inclusion": "Start the inclusion process again on your HUB and tap the Configuration Button three (3) times.\n\nPlease Note: If this doesn't work, you can check to see if your switch is within Z-Wave Range by holding down the Configuration Button for 5-10 seconds (if it's not within range, the LED Bar will indicate Red and if it is within Range, the LED Bar will indicate Green). If your switch indicates Red, please move the switch closer to the HUB. If your switch indicates Green, please try running an Exclusion to reset your switch",
|
|
724
|
+
"exclusion": "To Exclude your dimmer, put your HUB in exclusion mode and press the Configuration Button three (3) times",
|
|
725
|
+
"reset": "You may factory reset the switch by holding down the Config Button for twenty (20) or more seconds. The LED Bar will turn Red and blink three (3) times to confirm. \n\nHowever, we recommend using a certified Z-Wave controller to remove the device from your network for factory resetting the switch. \n\nOnly use either of these procedures in the event that the network primary controller is missing or otherwise inoperable",
|
|
726
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4206/LZW31-SN%20Manual%20-%20Inovelli%20Dimmer%20Switch%20(Red%20Series)%20-%2006.28.21.pdf"
|
|
727
|
+
}
|
|
721
728
|
}
|
|
@@ -0,0 +1,201 @@
|
|
|
1
|
+
{
|
|
2
|
+
"manufacturer": "ShenZhen Sunricher Technology, Ltd.",
|
|
3
|
+
"manufacturerId": "0x0330",
|
|
4
|
+
"label": "SR-ZV9021A",
|
|
5
|
+
"description": "Z-Wave Smart Plug",
|
|
6
|
+
"devices": [
|
|
7
|
+
{
|
|
8
|
+
"productType": "0x0200",
|
|
9
|
+
"productId": "0xd004",
|
|
10
|
+
"zwaveAllianceId": 4302
|
|
11
|
+
}
|
|
12
|
+
],
|
|
13
|
+
"firmwareVersion": {
|
|
14
|
+
"min": "0.0",
|
|
15
|
+
"max": "255.255"
|
|
16
|
+
},
|
|
17
|
+
"associations": {
|
|
18
|
+
"1": {
|
|
19
|
+
"label": "Lifeline",
|
|
20
|
+
"maxNodes": 5,
|
|
21
|
+
"isLifeline": true
|
|
22
|
+
}
|
|
23
|
+
},
|
|
24
|
+
"paramInformation": [
|
|
25
|
+
{
|
|
26
|
+
"#": "7",
|
|
27
|
+
"label": "Operating Mode",
|
|
28
|
+
"valueSize": 1,
|
|
29
|
+
"minValue": 0,
|
|
30
|
+
"maxValue": 1,
|
|
31
|
+
"defaultValue": 0,
|
|
32
|
+
"unsigned": true,
|
|
33
|
+
"allowManualEntry": false,
|
|
34
|
+
"options": [
|
|
35
|
+
{
|
|
36
|
+
"label": "Switch mode",
|
|
37
|
+
"value": 0
|
|
38
|
+
},
|
|
39
|
+
{
|
|
40
|
+
"label": "Thermostat mode",
|
|
41
|
+
"value": 1
|
|
42
|
+
}
|
|
43
|
+
]
|
|
44
|
+
},
|
|
45
|
+
{
|
|
46
|
+
"#": "8",
|
|
47
|
+
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
48
|
+
"label": "Report Setpoint & Mode Changes",
|
|
49
|
+
"defaultValue": 1
|
|
50
|
+
},
|
|
51
|
+
{
|
|
52
|
+
"#": "9",
|
|
53
|
+
"label": "Temperature Threshold",
|
|
54
|
+
"valueSize": 1,
|
|
55
|
+
"unit": "0.1 °C",
|
|
56
|
+
"minValue": -50,
|
|
57
|
+
"maxValue": 50,
|
|
58
|
+
"defaultValue": 0
|
|
59
|
+
},
|
|
60
|
+
{
|
|
61
|
+
"#": "10",
|
|
62
|
+
"label": "Overheat Protection",
|
|
63
|
+
"valueSize": 1,
|
|
64
|
+
"unit": "°C",
|
|
65
|
+
"minValue": 0,
|
|
66
|
+
"maxValue": 60,
|
|
67
|
+
"defaultValue": 36,
|
|
68
|
+
"unsigned": true,
|
|
69
|
+
"options": [
|
|
70
|
+
{
|
|
71
|
+
"label": "Disable",
|
|
72
|
+
"value": 0
|
|
73
|
+
}
|
|
74
|
+
]
|
|
75
|
+
},
|
|
76
|
+
{
|
|
77
|
+
"#": "11",
|
|
78
|
+
"label": "Automatic Reporting: Temperature Change Reporting Threshold",
|
|
79
|
+
"valueSize": 1,
|
|
80
|
+
"unit": "0.1 °C",
|
|
81
|
+
"minValue": 0,
|
|
82
|
+
"maxValue": 50,
|
|
83
|
+
"defaultValue": 2,
|
|
84
|
+
"unsigned": true,
|
|
85
|
+
"options": [
|
|
86
|
+
{
|
|
87
|
+
"label": "Disable",
|
|
88
|
+
"value": 0
|
|
89
|
+
}
|
|
90
|
+
]
|
|
91
|
+
},
|
|
92
|
+
{
|
|
93
|
+
"#": "12",
|
|
94
|
+
"label": "Automatic Reporting: Temperature Reporting Interval",
|
|
95
|
+
"description": "Allowable range: 10-65535",
|
|
96
|
+
"valueSize": 2,
|
|
97
|
+
"unit": "seconds",
|
|
98
|
+
"minValue": 0,
|
|
99
|
+
"maxValue": 65535,
|
|
100
|
+
"defaultValue": 300,
|
|
101
|
+
"unsigned": true,
|
|
102
|
+
"options": [
|
|
103
|
+
{
|
|
104
|
+
"label": "Disable",
|
|
105
|
+
"value": 0
|
|
106
|
+
}
|
|
107
|
+
]
|
|
108
|
+
},
|
|
109
|
+
{
|
|
110
|
+
"#": "13",
|
|
111
|
+
"label": "Automatic Reporting: Power Change Threshold",
|
|
112
|
+
"valueSize": 1,
|
|
113
|
+
"unit": "W",
|
|
114
|
+
"minValue": 0,
|
|
115
|
+
"maxValue": 255,
|
|
116
|
+
"defaultValue": 5,
|
|
117
|
+
"unsigned": true,
|
|
118
|
+
"options": [
|
|
119
|
+
{
|
|
120
|
+
"label": "Disable",
|
|
121
|
+
"value": 0
|
|
122
|
+
}
|
|
123
|
+
]
|
|
124
|
+
},
|
|
125
|
+
{
|
|
126
|
+
"#": "14",
|
|
127
|
+
"label": "Automatic Reporting: Voltage Change Threshold",
|
|
128
|
+
"valueSize": 1,
|
|
129
|
+
"unit": "V",
|
|
130
|
+
"minValue": 0,
|
|
131
|
+
"maxValue": 127,
|
|
132
|
+
"defaultValue": 2,
|
|
133
|
+
"unsigned": true,
|
|
134
|
+
"options": [
|
|
135
|
+
{
|
|
136
|
+
"label": "Disable",
|
|
137
|
+
"value": 0
|
|
138
|
+
}
|
|
139
|
+
]
|
|
140
|
+
},
|
|
141
|
+
{
|
|
142
|
+
"#": "15",
|
|
143
|
+
"label": "Automatic Reporting: Current Change Threshold",
|
|
144
|
+
"valueSize": 1,
|
|
145
|
+
"unit": "0.1 A",
|
|
146
|
+
"minValue": 0,
|
|
147
|
+
"maxValue": 255,
|
|
148
|
+
"defaultValue": 10,
|
|
149
|
+
"unsigned": true,
|
|
150
|
+
"options": [
|
|
151
|
+
{
|
|
152
|
+
"label": "Disable",
|
|
153
|
+
"value": 0
|
|
154
|
+
}
|
|
155
|
+
]
|
|
156
|
+
},
|
|
157
|
+
{
|
|
158
|
+
"#": "17",
|
|
159
|
+
"label": "Automatic Reporting: Energy Reports Interval",
|
|
160
|
+
"valueSize": 4,
|
|
161
|
+
"unit": "seconds",
|
|
162
|
+
"minValue": 60,
|
|
163
|
+
"maxValue": 2678400,
|
|
164
|
+
"defaultValue": 600,
|
|
165
|
+
"unsigned": true
|
|
166
|
+
},
|
|
167
|
+
{
|
|
168
|
+
"#": "18",
|
|
169
|
+
"$import": "~/templates/master_template.json#state_after_power_failure_off_on_prev"
|
|
170
|
+
},
|
|
171
|
+
{
|
|
172
|
+
"#": "19",
|
|
173
|
+
"$import": "~/templates/master_template.json#base_enable_disable",
|
|
174
|
+
"label": "Send Binary Reports",
|
|
175
|
+
"defaultValue": 1
|
|
176
|
+
},
|
|
177
|
+
{
|
|
178
|
+
"#": "20",
|
|
179
|
+
"label": "Overcurrent Protection",
|
|
180
|
+
"description": "Allowable range: 10-16",
|
|
181
|
+
"valueSize": 1,
|
|
182
|
+
"unit": "A",
|
|
183
|
+
"minValue": 0,
|
|
184
|
+
"maxValue": 16,
|
|
185
|
+
"defaultValue": 16,
|
|
186
|
+
"unsigned": true,
|
|
187
|
+
"options": [
|
|
188
|
+
{
|
|
189
|
+
"label": "Disable",
|
|
190
|
+
"value": 0
|
|
191
|
+
}
|
|
192
|
+
]
|
|
193
|
+
}
|
|
194
|
+
],
|
|
195
|
+
"metadata": {
|
|
196
|
+
"inclusion": "Triple press the action button on the smart plug, it will set the plug into inclusion mode.The LED indicator will flash a white LED fast then stay solid white for 3 seconds to indicate successful inclusion. If there is no Z-Wave network available, the LED indicator will flash white fast for 30 seconds and the plug will quit inclusion mode automatically",
|
|
197
|
+
"exclusion": "Triple press the action button, the smart plug will be set to exclusion mode, the LED indicator will flash a\nwhite LED fast and then flash white slowly for 3 times to indicate successful exclusion. If exclusion fails, the\nLED indicator will flash fast for 30 seconds and the plug will quit exclusion mode automatically",
|
|
198
|
+
"reset": "Press and hold down action button for over 10 seconds, LED indicator stays solid white for 3s to indicate\nsuccessful factory reset, release action button, the smart plug will restart automatically",
|
|
199
|
+
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4302/SR-ZV9021A%20Instruction%20ForRelease.pdf"
|
|
200
|
+
}
|
|
201
|
+
}
|