openstudio-standards 0.2.12.rc4 → 0.2.13.rc3
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
- data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
- data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
- data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
- data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
- data/data/geometry/ASHRAECourthouse.json +112 -0
- data/data/geometry/ASHRAECourthouse.osm +26470 -0
- data/data/geometry/ASHRAELargeHotel.osm +11 -1
- data/data/geometry/ASHRAELargeOffice.json +4 -0
- data/data/geometry/ASHRAESmallDataCenter.json +1 -1
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/exclude_list.csv +19 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/manage_OpenStudio_Standards.rb +87 -37
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +191 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +17 -0
- data/data/standards/test_performance_expected_dd_results.csv +1971 -1171
- data/lib/openstudio-standards.rb +76 -18
- data/lib/openstudio-standards/btap/btap.model.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +14 -11
- data/lib/openstudio-standards/btap/envelope.rb +185 -257
- data/lib/openstudio-standards/btap/fileio.rb +1 -0
- data/lib/openstudio-standards/btap/geometry.rb +21 -1
- data/lib/openstudio-standards/btap/measures.rb +12 -11
- data/lib/openstudio-standards/btap/schedules.rb +3 -12
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.rb +178 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXMultiSpeed.rb +8 -8
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +3 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +23 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +230 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +575 -345
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +142 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/refs/references.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +70 -51
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +91 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +30 -9
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +37 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
- data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +305 -247
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
- data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
- data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
- data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +76 -25
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +85 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +70 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +105 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +104 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +32 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +112 -25
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +37 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +125 -41
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +172 -55
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1662 -332
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +4994 -234
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +5967 -2727
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +5920 -2700
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +2011 -1112
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +1946 -1106
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
- data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
- data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +2 -18
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +87 -15
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +31 -19
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/curves.json +75 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -16
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +913 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/equip_eff_lim.json +52 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +109 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +23 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +803 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +787 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +100 -0
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +33 -0
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1729 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +68 -33
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +24 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +110 -99
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +24 -24
- data/lib/openstudio-standards/standards/necb/NECB2011/data/curves.json +50 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +31 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/led_lighting_data.json +2028 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1745 -1297
- data/lib/openstudio-standards/standards/necb/NECB2011/daylighting_control.md +70 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/demand_controlled_ventilation.md +46 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +69 -107
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +41 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +139 -141
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +38 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +492 -240
- data/lib/openstudio-standards/standards/necb/NECB2011/led_lighting.md +51 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +75 -9
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +1229 -37
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +11 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +32 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +29 -0
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
- data/lib/openstudio-standards/standards/standard.rb +6 -5
- data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
- data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
- data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
- data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
- data/lib/openstudio-standards/utilities/logging.rb +7 -7
- data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
- data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
- data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
- data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
- data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
- data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
- data/lib/openstudio-standards/utilities/simulation.rb +13 -21
- data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
- data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
- data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
- data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
- data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
- data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +112 -87
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
- metadata +236 -2
@@ -7356,6 +7356,93 @@
|
|
7356
7356
|
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
7357
7357
|
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
|
7358
7358
|
},
|
7359
|
+
{
|
7360
|
+
"template": "90.1-2007",
|
7361
|
+
"building_type": "LargeHotel",
|
7362
|
+
"space_type": "GuestRoom8",
|
7363
|
+
"lighting_standard": "ASHRAE 90.1-2007",
|
7364
|
+
"lighting_primary_space_type": "Hotel/Motel",
|
7365
|
+
"lighting_secondary_space_type": "Guest Rooms",
|
7366
|
+
"lighting_per_area": 1.1,
|
7367
|
+
"rcr_threshold": null,
|
7368
|
+
"lighting_per_person": null,
|
7369
|
+
"additional_lighting_per_area": null,
|
7370
|
+
"lighting_fraction_to_return_air": 0.0,
|
7371
|
+
"lighting_fraction_radiant": 0.7,
|
7372
|
+
"lighting_fraction_visible": 0.2,
|
7373
|
+
"lighting_fraction_replaceable": 1.0,
|
7374
|
+
"lpd_fraction_linear_fluorescent": 1.0,
|
7375
|
+
"lpd_fraction_compact_fluorescent": null,
|
7376
|
+
"lpd_fraction_high_bay": null,
|
7377
|
+
"lpd_fraction_specialty_lighting": null,
|
7378
|
+
"lpd_fraction_exit_lighting": null,
|
7379
|
+
"lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
|
7380
|
+
"compact_fluorescent_lighting_schedule": null,
|
7381
|
+
"high_bay_lighting_schedule": null,
|
7382
|
+
"specialty_lighting_schedule": null,
|
7383
|
+
"exit_lighting_schedule": null,
|
7384
|
+
"target_illuminance_setpoint": null,
|
7385
|
+
"psa_nongeometry_fraction": null,
|
7386
|
+
"ssa_nongeometry_fraction": null,
|
7387
|
+
"notes": null,
|
7388
|
+
"gas_equipment_per_area": null,
|
7389
|
+
"gas_equipment_fraction_latent": null,
|
7390
|
+
"gas_equipment_fraction_radiant": null,
|
7391
|
+
"gas_equipment_fraction_lost": null,
|
7392
|
+
"gas_equipment_schedule": null,
|
7393
|
+
"electric_equipment_per_area": 0.977,
|
7394
|
+
"electric_equipment_fraction_latent": 0.0,
|
7395
|
+
"electric_equipment_fraction_radiant": 0.5,
|
7396
|
+
"electric_equipment_fraction_lost": 0.0,
|
7397
|
+
"electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
|
7398
|
+
"additional_electric_equipment_schedule": null,
|
7399
|
+
"additional_gas_equipment_schedule": null,
|
7400
|
+
"ventilation_standard": "ASHRAE 62.1-2007",
|
7401
|
+
"ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
|
7402
|
+
"ventilation_secondary_space_type": "Bedroom/living Room",
|
7403
|
+
"ventilation_per_area": 0.06,
|
7404
|
+
"ventilation_per_person": 5.0,
|
7405
|
+
"ventilation_air_changes": null,
|
7406
|
+
"minimum_total_air_changes": null,
|
7407
|
+
"occupancy_per_area": 5.68,
|
7408
|
+
"occupancy_schedule": "Always Off",
|
7409
|
+
"occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
|
7410
|
+
"is_residential": "Yes",
|
7411
|
+
"infiltration_per_exterior_area": 0.112,
|
7412
|
+
"infiltration_per_exterior_wall_area": null,
|
7413
|
+
"infiltration_air_changes": null,
|
7414
|
+
"infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
|
7415
|
+
"infiltration_schedule_perimeter": null,
|
7416
|
+
"heating_setpoint_schedule": "HotelLarge VAC_OccGuestRoom_HtgSP_Sch",
|
7417
|
+
"cooling_setpoint_schedule": "HotelLarge VAC_OccGuestRoom_ClgSP_Sch",
|
7418
|
+
"service_water_heating_peak_flow_rate": 1.25,
|
7419
|
+
"service_water_heating_area": 264.0,
|
7420
|
+
"service_water_heating_peak_flow_per_area": 0.004734848485,
|
7421
|
+
"service_water_heating_system_type": "Shared",
|
7422
|
+
"booster_water_heater_fraction": null,
|
7423
|
+
"service_water_heating_target_temperature": 140.0,
|
7424
|
+
"booster_water_heating_target_temperature": null,
|
7425
|
+
"service_water_heating_fraction_sensible": 0.2,
|
7426
|
+
"service_water_heating_fraction_latent": 0.05,
|
7427
|
+
"service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
|
7428
|
+
"exhaust_per_area": null,
|
7429
|
+
"exhaust_fan_efficiency": null,
|
7430
|
+
"exhaust_fan_power": null,
|
7431
|
+
"exhaust_fan_pressure_rise": null,
|
7432
|
+
"exhaust_fan_maximum_flow_rate": null,
|
7433
|
+
"exhaust_availability_schedule": null,
|
7434
|
+
"exhaust_flow_fraction_schedule": null,
|
7435
|
+
"balanced_exhaust_fraction_schedule": null,
|
7436
|
+
"manual_continuous_dimming": null,
|
7437
|
+
"programmable_multilevel_dimming": null,
|
7438
|
+
"multilevel_occupancy_sensors": null,
|
7439
|
+
"occupancy_sensors": null,
|
7440
|
+
"occupancy_sensors_with_personal_continuous_dimming": null,
|
7441
|
+
"automatic_multilevel_switching_in_primary_sidelighted_areas": null,
|
7442
|
+
"automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
|
7443
|
+
"automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
|
7444
|
+
"automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
|
7445
|
+
},
|
7359
7446
|
{
|
7360
7447
|
"template": "90.1-2007",
|
7361
7448
|
"building_type": "LargeHotel",
|
@@ -13079,7 +13166,7 @@
|
|
13079
13166
|
"template": "90.1-2007",
|
13080
13167
|
"building_type": "Office",
|
13081
13168
|
"space_type": "WholeBuilding - Sm Office",
|
13082
|
-
"lighting_standard": "ASHRAE 90.1-
|
13169
|
+
"lighting_standard": "ASHRAE 90.1-2007",
|
13083
13170
|
"lighting_primary_space_type": "Whole Building",
|
13084
13171
|
"lighting_secondary_space_type": "Office",
|
13085
13172
|
"lighting_per_area": 1.0,
|
@@ -18975,7 +19062,7 @@
|
|
18975
19062
|
"template": "90.1-2007",
|
18976
19063
|
"building_type": "SmallHotel",
|
18977
19064
|
"space_type": "Elec/MechRoom",
|
18978
|
-
"lighting_standard": "
|
19065
|
+
"lighting_standard": "ASHRAE 90.1-2007",
|
18979
19066
|
"lighting_primary_space_type": "SmallHotel",
|
18980
19067
|
"lighting_secondary_space_type": "Elec/MechRoom",
|
18981
19068
|
"lighting_per_area": 0.0,
|
@@ -19063,7 +19150,7 @@
|
|
19063
19150
|
"template": "90.1-2007",
|
19064
19151
|
"building_type": "SmallHotel",
|
19065
19152
|
"space_type": "ElevatorCore",
|
19066
|
-
"lighting_standard": "
|
19153
|
+
"lighting_standard": "ASHRAE 90.1-2007",
|
19067
19154
|
"lighting_primary_space_type": "SmallHotel",
|
19068
19155
|
"lighting_secondary_space_type": "ElevatorCore",
|
19069
19156
|
"lighting_per_area": 0.0,
|
@@ -19151,7 +19238,7 @@
|
|
19151
19238
|
"template": "90.1-2007",
|
19152
19239
|
"building_type": "SmallHotel",
|
19153
19240
|
"space_type": "ElevatorCore4",
|
19154
|
-
"lighting_standard": "
|
19241
|
+
"lighting_standard": "ASHRAE 90.1-2007",
|
19155
19242
|
"lighting_primary_space_type": "SmallHotel",
|
19156
19243
|
"lighting_secondary_space_type": "ElevatorCore",
|
19157
19244
|
"lighting_per_area": 0.0,
|
@@ -20741,7 +20828,7 @@
|
|
20741
20828
|
"lighting_per_area": 1.5,
|
20742
20829
|
"rcr_threshold": null,
|
20743
20830
|
"lighting_per_person": null,
|
20744
|
-
"additional_lighting_per_area": 0
|
20831
|
+
"additional_lighting_per_area": 1.0,
|
20745
20832
|
"lighting_fraction_to_return_air": 0.0,
|
20746
20833
|
"lighting_fraction_radiant": 0.7,
|
20747
20834
|
"lighting_fraction_visible": 0.2,
|
@@ -20829,7 +20916,7 @@
|
|
20829
20916
|
"lighting_per_area": 1.5,
|
20830
20917
|
"rcr_threshold": null,
|
20831
20918
|
"lighting_per_person": null,
|
20832
|
-
"additional_lighting_per_area": 0.
|
20919
|
+
"additional_lighting_per_area": 0.959,
|
20833
20920
|
"lighting_fraction_to_return_air": 0.0,
|
20834
20921
|
"lighting_fraction_radiant": 0.7,
|
20835
20922
|
"lighting_fraction_visible": 0.2,
|
@@ -20917,7 +21004,7 @@
|
|
20917
21004
|
"lighting_per_area": 1.5,
|
20918
21005
|
"rcr_threshold": null,
|
20919
21006
|
"lighting_per_person": null,
|
20920
|
-
"additional_lighting_per_area": 0.
|
21007
|
+
"additional_lighting_per_area": 0.0,
|
20921
21008
|
"lighting_fraction_to_return_air": 0.0,
|
20922
21009
|
"lighting_fraction_radiant": 0.7,
|
20923
21010
|
"lighting_fraction_visible": 0.2,
|
@@ -21090,7 +21177,7 @@
|
|
21090
21177
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21091
21178
|
"lighting_primary_space_type": "Supermarket",
|
21092
21179
|
"lighting_secondary_space_type": "Corridor",
|
21093
|
-
"lighting_per_area": 0.
|
21180
|
+
"lighting_per_area": 0.5,
|
21094
21181
|
"rcr_threshold": null,
|
21095
21182
|
"lighting_per_person": null,
|
21096
21183
|
"additional_lighting_per_area": null,
|
@@ -21266,7 +21353,7 @@
|
|
21266
21353
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21267
21354
|
"lighting_primary_space_type": "Supermarket",
|
21268
21355
|
"lighting_secondary_space_type": "Dining",
|
21269
|
-
"lighting_per_area": 0.
|
21356
|
+
"lighting_per_area": 0.9,
|
21270
21357
|
"rcr_threshold": null,
|
21271
21358
|
"lighting_per_person": null,
|
21272
21359
|
"additional_lighting_per_area": null,
|
@@ -21354,7 +21441,7 @@
|
|
21354
21441
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21355
21442
|
"lighting_primary_space_type": "Supermarket",
|
21356
21443
|
"lighting_secondary_space_type": "DryStorage",
|
21357
|
-
"lighting_per_area": 0.
|
21444
|
+
"lighting_per_area": 0.8,
|
21358
21445
|
"rcr_threshold": null,
|
21359
21446
|
"lighting_per_person": null,
|
21360
21447
|
"additional_lighting_per_area": null,
|
@@ -21442,7 +21529,7 @@
|
|
21442
21529
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21443
21530
|
"lighting_primary_space_type": "Supermarket",
|
21444
21531
|
"lighting_secondary_space_type": "Elec/Mech",
|
21445
|
-
"lighting_per_area": 1.
|
21532
|
+
"lighting_per_area": 1.5,
|
21446
21533
|
"rcr_threshold": null,
|
21447
21534
|
"lighting_per_person": null,
|
21448
21535
|
"additional_lighting_per_area": null,
|
@@ -21706,7 +21793,7 @@
|
|
21706
21793
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21707
21794
|
"lighting_primary_space_type": "Supermarket",
|
21708
21795
|
"lighting_secondary_space_type": "Sales/Produce",
|
21709
|
-
"lighting_per_area":
|
21796
|
+
"lighting_per_area": 1.7,
|
21710
21797
|
"rcr_threshold": null,
|
21711
21798
|
"lighting_per_person": null,
|
21712
21799
|
"additional_lighting_per_area": null,
|
@@ -21794,7 +21881,7 @@
|
|
21794
21881
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21795
21882
|
"lighting_primary_space_type": "Supermarket",
|
21796
21883
|
"lighting_secondary_space_type": "Restroom",
|
21797
|
-
"lighting_per_area": 0.
|
21884
|
+
"lighting_per_area": 0.9,
|
21798
21885
|
"rcr_threshold": null,
|
21799
21886
|
"lighting_per_person": null,
|
21800
21887
|
"additional_lighting_per_area": null,
|
@@ -21882,7 +21969,7 @@
|
|
21882
21969
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21883
21970
|
"lighting_primary_space_type": "Supermarket",
|
21884
21971
|
"lighting_secondary_space_type": "Sales/Produce",
|
21885
|
-
"lighting_per_area":
|
21972
|
+
"lighting_per_area": 1.7,
|
21886
21973
|
"rcr_threshold": null,
|
21887
21974
|
"lighting_per_person": null,
|
21888
21975
|
"additional_lighting_per_area": null,
|
@@ -21970,7 +22057,7 @@
|
|
21970
22057
|
"lighting_standard": "ASHRAE 90.1-2007",
|
21971
22058
|
"lighting_primary_space_type": "Supermarket",
|
21972
22059
|
"lighting_secondary_space_type": "Vestibule",
|
21973
|
-
"lighting_per_area": 0.
|
22060
|
+
"lighting_per_area": 0.5,
|
21974
22061
|
"rcr_threshold": null,
|
21975
22062
|
"lighting_per_person": null,
|
21976
22063
|
"additional_lighting_per_area": null,
|
@@ -22058,7 +22145,7 @@
|
|
22058
22145
|
"lighting_standard": "ASHRAE 90.1-2007",
|
22059
22146
|
"lighting_primary_space_type": "Warehouse",
|
22060
22147
|
"lighting_secondary_space_type": "Medium/Bulky Material Storage",
|
22061
|
-
"lighting_per_area": 0.
|
22148
|
+
"lighting_per_area": 0.9,
|
22062
22149
|
"rcr_threshold": null,
|
22063
22150
|
"lighting_per_person": null,
|
22064
22151
|
"additional_lighting_per_area": null,
|
@@ -22146,7 +22233,7 @@
|
|
22146
22233
|
"lighting_standard": "ASHRAE 90.1-2007",
|
22147
22234
|
"lighting_primary_space_type": "Warehouse",
|
22148
22235
|
"lighting_secondary_space_type": "Fine Material Storage",
|
22149
|
-
"lighting_per_area":
|
22236
|
+
"lighting_per_area": 1.4,
|
22150
22237
|
"rcr_threshold": null,
|
22151
22238
|
"lighting_per_person": null,
|
22152
22239
|
"additional_lighting_per_area": null,
|
@@ -269,11 +269,11 @@
|
|
269
269
|
"ptac_eer_coefficient_1": null,
|
270
270
|
"ptac_eer_coefficient_2": null,
|
271
271
|
"minimum_scop": 2.2,
|
272
|
-
"cool_cap_ft": "
|
273
|
-
"cool_cap_fflow": "
|
274
|
-
"cool_eir_ft": "
|
275
|
-
"cool_eir_fflow": "
|
276
|
-
"cool_plf_fplr": "
|
272
|
+
"cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT",
|
273
|
+
"cool_cap_fflow": "DX Coil Cap-FF",
|
274
|
+
"cool_eir_ft": "PSZ-AC DX Coil EIR-FT",
|
275
|
+
"cool_eir_fflow": "Split DX Coil EIR-FF",
|
276
|
+
"cool_plf_fplr": "HPACCOOLPLFFPLR",
|
277
277
|
"notes": "2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units"
|
278
278
|
},
|
279
279
|
{
|
@@ -292,11 +292,11 @@
|
|
292
292
|
"ptac_eer_coefficient_1": null,
|
293
293
|
"ptac_eer_coefficient_2": null,
|
294
294
|
"minimum_scop": 2.1,
|
295
|
-
"cool_cap_ft": "
|
296
|
-
"cool_cap_fflow": "
|
297
|
-
"cool_eir_ft": "
|
298
|
-
"cool_eir_fflow": "
|
299
|
-
"cool_plf_fplr": "
|
295
|
+
"cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT",
|
296
|
+
"cool_cap_fflow": "DX Coil Cap-FF",
|
297
|
+
"cool_eir_ft": "PSZ-AC DX Coil EIR-FT",
|
298
|
+
"cool_eir_fflow": "Split DX Coil EIR-FF",
|
299
|
+
"cool_plf_fplr": "HPACCOOLPLFFPLR",
|
300
300
|
"notes": "2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units"
|
301
301
|
},
|
302
302
|
{
|
@@ -315,11 +315,11 @@
|
|
315
315
|
"ptac_eer_coefficient_1": null,
|
316
316
|
"ptac_eer_coefficient_2": null,
|
317
317
|
"minimum_scop": 1.9,
|
318
|
-
"cool_cap_ft": "
|
319
|
-
"cool_cap_fflow": "
|
320
|
-
"cool_eir_ft": "
|
321
|
-
"cool_eir_fflow": "
|
322
|
-
"cool_plf_fplr": "
|
318
|
+
"cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT",
|
319
|
+
"cool_cap_fflow": "DX Coil Cap-FF",
|
320
|
+
"cool_eir_ft": "PSZ-AC DX Coil EIR-FT",
|
321
|
+
"cool_eir_fflow": "Split DX Coil EIR-FF",
|
322
|
+
"cool_plf_fplr": "HPACCOOLPLFFPLR",
|
323
323
|
"notes": "2007 not specified, follow ASHRAE 90.1-2013 Table 6.8.1-11. capacity here is sensible only. SCOP for downflow units"
|
324
324
|
},
|
325
325
|
{
|
data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb
CHANGED
@@ -13,7 +13,7 @@ class ASHRAE9012010 < ASHRAE901
|
|
13
13
|
# First time adjustment:
|
14
14
|
# Only applies to multi-zone vav systems
|
15
15
|
# exclusion: for Outpatient: (1) both AHU1 and AHU2 in 'DOE Ref Pre-1980' and 'DOE Ref 1980-2004'
|
16
|
-
# (2) AHU1 in 2004-
|
16
|
+
# (2) AHU1 in 2004-2019
|
17
17
|
# TODO refactor: move building-type-specific code to Prototype classes
|
18
18
|
if air_loop_hvac_multizone_vav_system?(air_loop_hvac) && !(air_loop_hvac.name.to_s.include? 'Outpatient F1')
|
19
19
|
air_loop_hvac_adjust_minimum_vav_damper_positions(air_loop_hvac)
|
@@ -32,11 +32,9 @@ class ASHRAE9012010 < ASHRAE901
|
|
32
32
|
|
33
33
|
# Get the OA system and OA controller
|
34
34
|
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
35
|
-
|
36
|
-
|
37
|
-
|
38
|
-
return [nil, nil, nil] # No OA system
|
39
|
-
end
|
35
|
+
return [nil, nil, nil] unless oa_sys.is_initialized # No OA system
|
36
|
+
|
37
|
+
oa_sys = oa_sys.get
|
40
38
|
oa_control = oa_sys.getControllerOutdoorAir
|
41
39
|
economizer_type = oa_control.getEconomizerControlType
|
42
40
|
|
@@ -45,8 +43,8 @@ class ASHRAE9012010 < ASHRAE901
|
|
45
43
|
return [nil, nil, nil]
|
46
44
|
when 'FixedDryBulb'
|
47
45
|
search_criteria = {
|
48
|
-
|
49
|
-
|
46
|
+
'template' => template,
|
47
|
+
'climate_zone' => climate_zone
|
50
48
|
}
|
51
49
|
econ_limits = model_find_object(standards_data['economizers'], search_criteria)
|
52
50
|
drybulb_limit_f = econ_limits['fixed_dry_bulb_high_limit_shutoff_temp']
|
@@ -102,7 +100,8 @@ class ASHRAE9012010 < ASHRAE901
|
|
102
100
|
# Determine the prohibited types
|
103
101
|
prohibited_types = []
|
104
102
|
case climate_zone
|
105
|
-
when 'ASHRAE 169-2006-
|
103
|
+
when 'ASHRAE 169-2006-0B',
|
104
|
+
'ASHRAE 169-2006-1B',
|
106
105
|
'ASHRAE 169-2006-2B',
|
107
106
|
'ASHRAE 169-2006-3B',
|
108
107
|
'ASHRAE 169-2006-3C',
|
@@ -114,6 +113,7 @@ class ASHRAE9012010 < ASHRAE901
|
|
114
113
|
'ASHRAE 169-2006-7B',
|
115
114
|
'ASHRAE 169-2006-8A',
|
116
115
|
'ASHRAE 169-2006-8B',
|
116
|
+
'ASHRAE 169-2013-0B',
|
117
117
|
'ASHRAE 169-2013-1B',
|
118
118
|
'ASHRAE 169-2013-2B',
|
119
119
|
'ASHRAE 169-2013-3B',
|
@@ -127,10 +127,12 @@ class ASHRAE9012010 < ASHRAE901
|
|
127
127
|
'ASHRAE 169-2013-8A',
|
128
128
|
'ASHRAE 169-2013-8B'
|
129
129
|
prohibited_types = ['FixedEnthalpy']
|
130
|
-
when 'ASHRAE 169-2006-
|
130
|
+
when 'ASHRAE 169-2006-0A',
|
131
|
+
'ASHRAE 169-2006-1A',
|
131
132
|
'ASHRAE 169-2006-2A',
|
132
133
|
'ASHRAE 169-2006-3A',
|
133
134
|
'ASHRAE 169-2006-4A',
|
135
|
+
'ASHRAE 169-2013-0A',
|
134
136
|
'ASHRAE 169-2013-1A',
|
135
137
|
'ASHRAE 169-2013-2A',
|
136
138
|
'ASHRAE 169-2013-3A',
|
@@ -154,6 +156,7 @@ class ASHRAE9012010 < ASHRAE901
|
|
154
156
|
|
155
157
|
# Determine if multizone vav optimization is required.
|
156
158
|
#
|
159
|
+
# @code_sections [90.1-2010_6.5.3.3]
|
157
160
|
# @param (see #economizer_required?)
|
158
161
|
# @return [Bool] Returns true if required, false if not.
|
159
162
|
# @todo Add exception logic for
|
@@ -175,6 +178,7 @@ class ASHRAE9012010 < ASHRAE901
|
|
175
178
|
end
|
176
179
|
|
177
180
|
# Not required for systems that require an ERV
|
181
|
+
# Exception 2 to Section 6.5.3.3
|
178
182
|
if air_loop_hvac_energy_recovery?(air_loop_hvac)
|
179
183
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: multizone vav optimization is not required because the system has Energy Recovery.")
|
180
184
|
return multizone_opt_required
|
@@ -255,14 +259,18 @@ class ASHRAE9012010 < ASHRAE901
|
|
255
259
|
# @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]
|
256
260
|
def air_loop_hvac_motorized_oa_damper_limits(air_loop_hvac, climate_zone)
|
257
261
|
case climate_zone
|
258
|
-
when 'ASHRAE 169-2006-
|
262
|
+
when 'ASHRAE 169-2006-0A',
|
263
|
+
'ASHRAE 169-2006-1A',
|
264
|
+
'ASHRAE 169-2006-0B',
|
259
265
|
'ASHRAE 169-2006-1B',
|
260
266
|
'ASHRAE 169-2006-2A',
|
261
267
|
'ASHRAE 169-2006-2B',
|
262
268
|
'ASHRAE 169-2006-3A',
|
263
269
|
'ASHRAE 169-2006-3B',
|
264
270
|
'ASHRAE 169-2006-3C',
|
271
|
+
'ASHRAE 169-2013-0A',
|
265
272
|
'ASHRAE 169-2013-1A',
|
273
|
+
'ASHRAE 169-2013-0B',
|
266
274
|
'ASHRAE 169-2013-1B',
|
267
275
|
'ASHRAE 169-2013-2A',
|
268
276
|
'ASHRAE 169-2013-2B',
|
@@ -312,15 +320,18 @@ class ASHRAE9012010 < ASHRAE901
|
|
312
320
|
end
|
313
321
|
|
314
322
|
case climate_zone
|
315
|
-
when 'ASHRAE 169-2006-
|
323
|
+
when 'ASHRAE 169-2006-0A',
|
324
|
+
'ASHRAE 169-2006-1A',
|
316
325
|
'ASHRAE 169-2006-2A',
|
317
326
|
'ASHRAE 169-2006-3A',
|
327
|
+
'ASHRAE 169-2013-0A',
|
318
328
|
'ASHRAE 169-2013-1A',
|
319
329
|
'ASHRAE 169-2013-2A',
|
320
330
|
'ASHRAE 169-2013-3A'
|
321
331
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.4 Exception 1, the system is located in climate zone #{climate_zone}.")
|
322
332
|
return is_sat_reset_required
|
323
|
-
when 'ASHRAE 169-2006-
|
333
|
+
when 'ASHRAE 169-2006-0B',
|
334
|
+
'ASHRAE 169-2006-1B',
|
324
335
|
'ASHRAE 169-2006-2B',
|
325
336
|
'ASHRAE 169-2006-3B',
|
326
337
|
'ASHRAE 169-2006-3C',
|
@@ -336,6 +347,7 @@ class ASHRAE9012010 < ASHRAE901
|
|
336
347
|
'ASHRAE 169-2006-7B',
|
337
348
|
'ASHRAE 169-2006-8A',
|
338
349
|
'ASHRAE 169-2006-8B',
|
350
|
+
'ASHRAE 169-2013-0B',
|
339
351
|
'ASHRAE 169-2013-1B',
|
340
352
|
'ASHRAE 169-2013-2B',
|
341
353
|
'ASHRAE 169-2013-3B',
|
@@ -365,10 +377,15 @@ class ASHRAE9012010 < ASHRAE901
|
|
365
377
|
def air_loop_hvac_energy_recovery_ventilator_flow_limit(air_loop_hvac, climate_zone, pct_oa)
|
366
378
|
# Table 6.5.6.1
|
367
379
|
search_criteria = {
|
368
|
-
|
369
|
-
|
380
|
+
'template' => template,
|
381
|
+
'climate_zone' => climate_zone
|
370
382
|
}
|
371
383
|
energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
|
384
|
+
if energy_recovery_limits.nil?
|
385
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2010.AirLoopHVAC', "Cannot find energy recovery limits for template '#{template}', climate zone '#{climate_zone}', assuming no energy recovery required.")
|
386
|
+
return nil
|
387
|
+
end
|
388
|
+
|
372
389
|
if pct_oa < 0.1
|
373
390
|
erv_cfm = nil
|
374
391
|
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb
CHANGED
@@ -39,7 +39,7 @@ class ASHRAE9012010 < ASHRAE901
|
|
39
39
|
# Check effective sidelighted aperture
|
40
40
|
sidelighted_effective_aperture = space_sidelighting_effective_aperture(space, areas['primary_sidelighted_area'])
|
41
41
|
OpenStudio.logFree(OpenStudio::Debug, 'openstudio.model.Space', "sidelighted_effective_aperture_pri = #{sidelighted_effective_aperture}")
|
42
|
-
if sidelighted_effective_aperture < 0.1
|
42
|
+
if sidelighted_effective_aperture < 0.1 && @instvarbuilding_type.nil?
|
43
43
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Space', "For #{space.name}, primary sidelighting control not required because sidelighted effective aperture less than 0.1 per 9.4.1.4 Exception b.")
|
44
44
|
req_pri_ctrl = false
|
45
45
|
end
|
@@ -341828,11 +341828,24 @@
|
|
341828
341828
|
"name": "Warehouse BLDG_LIGHT_OFFICE_SCH",
|
341829
341829
|
"category": "Lighting",
|
341830
341830
|
"units": null,
|
341831
|
-
"day_types": "
|
341831
|
+
"day_types": "SmrDsn",
|
341832
341832
|
"start_date": "2014-01-01T00:00:00+00:00",
|
341833
341833
|
"end_date": "2014-12-31T00:00:00+00:00",
|
341834
|
-
"type": "
|
341834
|
+
"type": "Constant",
|
341835
341835
|
"notes": "From DOE Prototype Buildings",
|
341836
|
+
"values": [
|
341837
|
+
1.0
|
341838
|
+
]
|
341839
|
+
},
|
341840
|
+
{
|
341841
|
+
"name": "Warehouse BLDG_LIGHT_OFFICE_SCH",
|
341842
|
+
"category": "Lighting",
|
341843
|
+
"units": null,
|
341844
|
+
"day_types": "Wkdy",
|
341845
|
+
"start_date": "2014-01-01T00:00:00+00:00",
|
341846
|
+
"end_date": "2014-12-31T00:00:00+00:00",
|
341847
|
+
"type": "Hourly",
|
341848
|
+
"notes": "From DOE Prototype Buildings. Day Types changed from Sat|Wkdy to Wkdy based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
341836
341849
|
"values": [
|
341837
341850
|
0.18,
|
341838
341851
|
0.18,
|
@@ -341860,19 +341873,6 @@
|
|
341860
341873
|
0.18
|
341861
341874
|
]
|
341862
341875
|
},
|
341863
|
-
{
|
341864
|
-
"name": "Warehouse BLDG_LIGHT_OFFICE_SCH",
|
341865
|
-
"category": "Lighting",
|
341866
|
-
"units": null,
|
341867
|
-
"day_types": "SmrDsn",
|
341868
|
-
"start_date": "2014-01-01T00:00:00+00:00",
|
341869
|
-
"end_date": "2014-12-31T00:00:00+00:00",
|
341870
|
-
"type": "Constant",
|
341871
|
-
"notes": "From DOE Prototype Buildings",
|
341872
|
-
"values": [
|
341873
|
-
1.0
|
341874
|
-
]
|
341875
|
-
},
|
341876
341876
|
{
|
341877
341877
|
"name": "Warehouse BLDG_LIGHT_OFFICE_SCH",
|
341878
341878
|
"category": "Lighting",
|
@@ -342053,11 +342053,24 @@
|
|
342053
342053
|
"name": "Warehouse BLDG_LIGHT_STORAGE_SCH",
|
342054
342054
|
"category": "Lighting",
|
342055
342055
|
"units": null,
|
342056
|
-
"day_types": "
|
342056
|
+
"day_types": "SmrDsn",
|
342057
342057
|
"start_date": "2014-01-01T00:00:00+00:00",
|
342058
342058
|
"end_date": "2014-12-31T00:00:00+00:00",
|
342059
|
-
"type": "
|
342059
|
+
"type": "Constant",
|
342060
342060
|
"notes": "From DOE Prototype Buildings",
|
342061
|
+
"values": [
|
342062
|
+
1.0
|
342063
|
+
]
|
342064
|
+
},
|
342065
|
+
{
|
342066
|
+
"name": "Warehouse BLDG_LIGHT_STORAGE_SCH",
|
342067
|
+
"category": "Lighting",
|
342068
|
+
"units": null,
|
342069
|
+
"day_types": "Wkdy",
|
342070
|
+
"start_date": "2014-01-01T00:00:00+00:00",
|
342071
|
+
"end_date": "2014-12-31T00:00:00+00:00",
|
342072
|
+
"type": "Hourly",
|
342073
|
+
"notes": "From DOE Prototype Buildings. Day Types changed from Sat|Wkdy to Wkdy based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
342061
342074
|
"values": [
|
342062
342075
|
0.1,
|
342063
342076
|
0.1,
|
@@ -342085,19 +342098,6 @@
|
|
342085
342098
|
0.1
|
342086
342099
|
]
|
342087
342100
|
},
|
342088
|
-
{
|
342089
|
-
"name": "Warehouse BLDG_LIGHT_STORAGE_SCH",
|
342090
|
-
"category": "Lighting",
|
342091
|
-
"units": null,
|
342092
|
-
"day_types": "SmrDsn",
|
342093
|
-
"start_date": "2014-01-01T00:00:00+00:00",
|
342094
|
-
"end_date": "2014-12-31T00:00:00+00:00",
|
342095
|
-
"type": "Constant",
|
342096
|
-
"notes": "From DOE Prototype Buildings",
|
342097
|
-
"values": [
|
342098
|
-
1.0
|
342099
|
-
]
|
342100
|
-
},
|
342101
342101
|
{
|
342102
342102
|
"name": "Warehouse BLDG_LIGHT_STORAGE_SCH",
|
342103
342103
|
"category": "Lighting",
|
@@ -342128,11 +342128,11 @@
|
|
342128
342128
|
"name": "Warehouse BLDG_OCC_SCH",
|
342129
342129
|
"category": "Occupancy",
|
342130
342130
|
"units": null,
|
342131
|
-
"day_types": "WntrDsn|SmrDsn|
|
342131
|
+
"day_types": "WntrDsn|SmrDsn|Wkdy",
|
342132
342132
|
"start_date": "2014-01-01T00:00:00+00:00",
|
342133
342133
|
"end_date": "2014-12-31T00:00:00+00:00",
|
342134
342134
|
"type": "Hourly",
|
342135
|
-
"notes": "From DOE Prototype Buildings",
|
342135
|
+
"notes": "From DOE Prototype Buildings. Day Types changed from WntrDsn|SmrDsn|Sat|Wkdy to WntrDsn|SmrDsn|Wkdy based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
342136
342136
|
"values": [
|
342137
342137
|
0.0,
|
342138
342138
|
0.0,
|
@@ -342177,7 +342177,7 @@
|
|
342177
342177
|
"name": "Warehouse Bldg Equip",
|
342178
342178
|
"category": "Equipment",
|
342179
342179
|
"units": null,
|
342180
|
-
"day_types": "
|
342180
|
+
"day_types": "SmrDsn",
|
342181
342181
|
"start_date": "2014-01-01T00:00:00+00:00",
|
342182
342182
|
"end_date": "2014-12-31T00:00:00+00:00",
|
342183
342183
|
"type": "Hourly",
|
@@ -342213,11 +342213,11 @@
|
|
342213
342213
|
"name": "Warehouse Bldg Equip",
|
342214
342214
|
"category": "Equipment",
|
342215
342215
|
"units": null,
|
342216
|
-
"day_types": "
|
342216
|
+
"day_types": "Wkdy",
|
342217
342217
|
"start_date": "2014-01-01T00:00:00+00:00",
|
342218
342218
|
"end_date": "2014-12-31T00:00:00+00:00",
|
342219
342219
|
"type": "Hourly",
|
342220
|
-
"notes": "From DOE Reference Buildings ",
|
342220
|
+
"notes": "From DOE Reference Buildings. Day Types changed from Mon|Tue|Wed|Thu|Fri|Sat to Wkdy based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
342221
342221
|
"values": [
|
342222
342222
|
0.25,
|
342223
342223
|
0.25,
|
@@ -342249,11 +342249,11 @@
|
|
342249
342249
|
"name": "Warehouse Bldg Equip",
|
342250
342250
|
"category": "Equipment",
|
342251
342251
|
"units": null,
|
342252
|
-
"day_types": "
|
342252
|
+
"day_types": "Wknd|Hol",
|
342253
342253
|
"start_date": "2014-01-01T00:00:00+00:00",
|
342254
342254
|
"end_date": "2014-12-31T00:00:00+00:00",
|
342255
342255
|
"type": "Constant",
|
342256
|
-
"notes": "From DOE Reference Buildings ",
|
342256
|
+
"notes": "From DOE Reference Buildings. Day Types changed from Sun|Hol to Wknd|Hol based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
342257
342257
|
"values": [
|
342258
342258
|
0.0
|
342259
342259
|
]
|
@@ -342441,42 +342441,6 @@
|
|
342441
342441
|
0.0
|
342442
342442
|
]
|
342443
342443
|
},
|
342444
|
-
{
|
342445
|
-
"name": "Warehouse Bldg Occ",
|
342446
|
-
"category": "Occupancy",
|
342447
|
-
"units": null,
|
342448
|
-
"day_types": "Sat",
|
342449
|
-
"start_date": "2014-01-01T00:00:00+00:00",
|
342450
|
-
"end_date": "2014-12-31T00:00:00+00:00",
|
342451
|
-
"type": "Hourly",
|
342452
|
-
"notes": "From DOE Reference Buildings ",
|
342453
|
-
"values": [
|
342454
|
-
0.0,
|
342455
|
-
0.0,
|
342456
|
-
0.0,
|
342457
|
-
0.0,
|
342458
|
-
0.0,
|
342459
|
-
0.0,
|
342460
|
-
0.0,
|
342461
|
-
0.0,
|
342462
|
-
0.2,
|
342463
|
-
0.2,
|
342464
|
-
0.2,
|
342465
|
-
0.2,
|
342466
|
-
0.1,
|
342467
|
-
0.1,
|
342468
|
-
0.1,
|
342469
|
-
0.1,
|
342470
|
-
0.0,
|
342471
|
-
0.0,
|
342472
|
-
0.0,
|
342473
|
-
0.0,
|
342474
|
-
0.0,
|
342475
|
-
0.0,
|
342476
|
-
0.0,
|
342477
|
-
0.0
|
342478
|
-
]
|
342479
|
-
},
|
342480
342444
|
{
|
342481
342445
|
"name": "Warehouse Bldg Occ",
|
342482
342446
|
"category": "Occupancy",
|
@@ -342494,11 +342458,11 @@
|
|
342494
342458
|
"name": "Warehouse Bldg Occ",
|
342495
342459
|
"category": "Occupancy",
|
342496
342460
|
"units": null,
|
342497
|
-
"day_types": "WntrDsn|
|
342461
|
+
"day_types": "WntrDsn|Wknd",
|
342498
342462
|
"start_date": "2014-01-01T00:00:00+00:00",
|
342499
342463
|
"end_date": "2014-12-31T00:00:00+00:00",
|
342500
342464
|
"type": "Constant",
|
342501
|
-
"notes": "From DOE Reference Buildings ",
|
342465
|
+
"notes": "From DOE Reference Buildings. Day Types changed from WntrDsn|Sun to WntrDsn|Wknd based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
342502
342466
|
"values": [
|
342503
342467
|
0.0
|
342504
342468
|
]
|
@@ -343715,11 +343679,24 @@
|
|
343715
343679
|
"name": "Warehouse Office_Plug_SCH",
|
343716
343680
|
"category": "Unknown",
|
343717
343681
|
"units": null,
|
343718
|
-
"day_types": "
|
343682
|
+
"day_types": "SmrDsn",
|
343719
343683
|
"start_date": "2014-01-01T00:00:00+00:00",
|
343720
343684
|
"end_date": "2014-12-31T00:00:00+00:00",
|
343721
|
-
"type": "
|
343685
|
+
"type": "Constant",
|
343722
343686
|
"notes": "From DOE Prototype Buildings",
|
343687
|
+
"values": [
|
343688
|
+
1.0
|
343689
|
+
]
|
343690
|
+
},
|
343691
|
+
{
|
343692
|
+
"name": "Warehouse Office_Plug_SCH",
|
343693
|
+
"category": "Unknown",
|
343694
|
+
"units": null,
|
343695
|
+
"day_types": "Wkdy",
|
343696
|
+
"start_date": "2014-01-01T00:00:00+00:00",
|
343697
|
+
"end_date": "2014-12-31T00:00:00+00:00",
|
343698
|
+
"type": "Hourly",
|
343699
|
+
"notes": "From DOE Prototype Buildings. Day Types changed from Sat|Wkdy to Wkdy based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
343723
343700
|
"values": [
|
343724
343701
|
0.25545,
|
343725
343702
|
0.25545,
|
@@ -343751,50 +343728,50 @@
|
|
343751
343728
|
"name": "Warehouse Office_Plug_SCH",
|
343752
343729
|
"category": "Unknown",
|
343753
343730
|
"units": null,
|
343754
|
-
"day_types": "
|
343731
|
+
"day_types": "WntrDsn",
|
343755
343732
|
"start_date": "2014-01-01T00:00:00+00:00",
|
343756
343733
|
"end_date": "2014-12-31T00:00:00+00:00",
|
343757
343734
|
"type": "Constant",
|
343758
343735
|
"notes": "From DOE Prototype Buildings",
|
343759
343736
|
"values": [
|
343760
|
-
|
343737
|
+
0.0
|
343761
343738
|
]
|
343762
343739
|
},
|
343763
343740
|
{
|
343764
|
-
"name": "Warehouse
|
343741
|
+
"name": "Warehouse Office_Plug_SCH_2013",
|
343765
343742
|
"category": "Unknown",
|
343766
343743
|
"units": null,
|
343767
|
-
"day_types": "
|
343744
|
+
"day_types": "Default",
|
343768
343745
|
"start_date": "2014-01-01T00:00:00+00:00",
|
343769
343746
|
"end_date": "2014-12-31T00:00:00+00:00",
|
343770
343747
|
"type": "Constant",
|
343771
343748
|
"notes": "From DOE Prototype Buildings",
|
343772
343749
|
"values": [
|
343773
|
-
0.
|
343750
|
+
0.25545
|
343774
343751
|
]
|
343775
343752
|
},
|
343776
343753
|
{
|
343777
343754
|
"name": "Warehouse Office_Plug_SCH_2013",
|
343778
343755
|
"category": "Unknown",
|
343779
343756
|
"units": null,
|
343780
|
-
"day_types": "
|
343757
|
+
"day_types": "SmrDsn",
|
343781
343758
|
"start_date": "2014-01-01T00:00:00+00:00",
|
343782
343759
|
"end_date": "2014-12-31T00:00:00+00:00",
|
343783
343760
|
"type": "Constant",
|
343784
343761
|
"notes": "From DOE Prototype Buildings",
|
343785
343762
|
"values": [
|
343786
|
-
0
|
343763
|
+
1.0
|
343787
343764
|
]
|
343788
343765
|
},
|
343789
343766
|
{
|
343790
343767
|
"name": "Warehouse Office_Plug_SCH_2013",
|
343791
343768
|
"category": "Unknown",
|
343792
343769
|
"units": null,
|
343793
|
-
"day_types": "
|
343770
|
+
"day_types": "Wkdy",
|
343794
343771
|
"start_date": "2014-01-01T00:00:00+00:00",
|
343795
343772
|
"end_date": "2014-12-31T00:00:00+00:00",
|
343796
343773
|
"type": "Hourly",
|
343797
|
-
"notes": "From DOE Prototype Buildings",
|
343774
|
+
"notes": "From DOE Prototype Buildings. Day Types changed from Sat|Wkdy to Wkdy based on EULP Calibration with AMI data from Fort Collins/PGE/Seattle",
|
343798
343775
|
"values": [
|
343799
343776
|
0.2456865339,
|
343800
343777
|
0.2456865339,
|
@@ -343822,19 +343799,6 @@
|
|
343822
343799
|
0.2456865339
|
343823
343800
|
]
|
343824
343801
|
},
|
343825
|
-
{
|
343826
|
-
"name": "Warehouse Office_Plug_SCH_2013",
|
343827
|
-
"category": "Unknown",
|
343828
|
-
"units": null,
|
343829
|
-
"day_types": "SmrDsn",
|
343830
|
-
"start_date": "2014-01-01T00:00:00+00:00",
|
343831
|
-
"end_date": "2014-12-31T00:00:00+00:00",
|
343832
|
-
"type": "Constant",
|
343833
|
-
"notes": "From DOE Prototype Buildings",
|
343834
|
-
"values": [
|
343835
|
-
1.0
|
343836
|
-
]
|
343837
|
-
},
|
343838
343802
|
{
|
343839
343803
|
"name": "Warehouse Office_Plug_SCH_2013",
|
343840
343804
|
"category": "Unknown",
|