openstudio-standards 0.2.12.rc4 → 0.2.13.rc3
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
- data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
- data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
- data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
- data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
- data/data/geometry/ASHRAECourthouse.json +112 -0
- data/data/geometry/ASHRAECourthouse.osm +26470 -0
- data/data/geometry/ASHRAELargeHotel.osm +11 -1
- data/data/geometry/ASHRAELargeOffice.json +4 -0
- data/data/geometry/ASHRAESmallDataCenter.json +1 -1
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/exclude_list.csv +19 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/manage_OpenStudio_Standards.rb +87 -37
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +191 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +17 -0
- data/data/standards/test_performance_expected_dd_results.csv +1971 -1171
- data/lib/openstudio-standards.rb +76 -18
- data/lib/openstudio-standards/btap/btap.model.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +14 -11
- data/lib/openstudio-standards/btap/envelope.rb +185 -257
- data/lib/openstudio-standards/btap/fileio.rb +1 -0
- data/lib/openstudio-standards/btap/geometry.rb +21 -1
- data/lib/openstudio-standards/btap/measures.rb +12 -11
- data/lib/openstudio-standards/btap/schedules.rb +3 -12
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.rb +178 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXMultiSpeed.rb +8 -8
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +3 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +23 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +230 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +575 -345
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +142 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/refs/references.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +70 -51
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +91 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +30 -9
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +37 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
- data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +305 -247
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
- data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
- data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
- data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +76 -25
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +85 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +70 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +105 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +104 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +32 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +112 -25
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +37 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +125 -41
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +172 -55
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1662 -332
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +4994 -234
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +5967 -2727
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +5920 -2700
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +2011 -1112
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +1946 -1106
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
- data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
- data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +2 -18
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +87 -15
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +31 -19
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/curves.json +75 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -16
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +913 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/equip_eff_lim.json +52 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +109 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +23 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +803 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +787 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +100 -0
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +33 -0
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1729 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +68 -33
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +24 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +110 -99
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +24 -24
- data/lib/openstudio-standards/standards/necb/NECB2011/data/curves.json +50 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +31 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/led_lighting_data.json +2028 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1745 -1297
- data/lib/openstudio-standards/standards/necb/NECB2011/daylighting_control.md +70 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/demand_controlled_ventilation.md +46 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +69 -107
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +41 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +139 -141
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +38 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +492 -240
- data/lib/openstudio-standards/standards/necb/NECB2011/led_lighting.md +51 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +75 -9
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +1229 -37
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +11 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +32 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +29 -0
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
- data/lib/openstudio-standards/standards/standard.rb +6 -5
- data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
- data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
- data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
- data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
- data/lib/openstudio-standards/utilities/logging.rb +7 -7
- data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
- data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
- data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
- data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
- data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
- data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
- data/lib/openstudio-standards/utilities/simulation.rb +13 -21
- data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
- data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
- data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
- data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
- data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
- data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +112 -87
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
- metadata +236 -2
@@ -807,6 +807,7 @@ module BTAP
|
|
807
807
|
next if field_name.include?('Cooling Control Zone or Zone List Name')
|
808
808
|
next if field_name.include?('Heating Control Zone or Zone List Name')
|
809
809
|
next if field_name.include?('Heating Zone Fans Only Zone or Zone List Name')
|
810
|
+
next if field_name.include?('Zone Terminal Unit List')
|
810
811
|
|
811
812
|
# Don't compare the names of schedule type limits
|
812
813
|
# because they appear to be created non-deteministically
|
@@ -2176,6 +2176,26 @@ module BTAP
|
|
2176
2176
|
end
|
2177
2177
|
|
2178
2178
|
|
2179
|
+
def self.rotate_building(model: , degrees: nil)
|
2180
|
+
|
2181
|
+
# report as not applicable if effective relative rotation is 0
|
2182
|
+
if degrees == 0 || degrees.nil?
|
2183
|
+
puts ('The requested rotation was 0 or nil degrees. The model was not rotated.')
|
2184
|
+
return
|
2185
|
+
end
|
2186
|
+
|
2187
|
+
# check the relative_building_rotation for reasonableness
|
2188
|
+
degrees -= 360.0 * (degrees / 360.0).truncate if (degrees > 360) || (degrees < -360)
|
2189
|
+
|
2190
|
+
# reporting initial condition of model
|
2191
|
+
building = model.getBuilding
|
2192
|
+
# rotate the building
|
2193
|
+
final_building_angle = building.setNorthAxis(building.northAxis + degrees)
|
2194
|
+
end
|
2195
|
+
|
2196
|
+
|
2197
|
+
|
2198
|
+
|
2179
2199
|
module BuildingStoreys
|
2180
2200
|
|
2181
2201
|
#This method will delete any exisiting stories and then try to assign stories based on
|
@@ -2824,7 +2844,7 @@ module BTAP
|
|
2824
2844
|
#a bit of acrobatics to get the construction object from the ConstrustionBase object's name.
|
2825
2845
|
construction = OpenStudio::Model::getConstructionByName(surface.model, surface.construction.get.name.to_s).get
|
2826
2846
|
#create a new construction with the requested RSI value based on the current construction.
|
2827
|
-
return BTAP::Resources::Envelope::Constructions::get_shgc(model,construction)
|
2847
|
+
return BTAP::Resources::Envelope::Constructions::get_shgc(surface.model,construction)
|
2828
2848
|
end
|
2829
2849
|
|
2830
2850
|
#This method gets the tvis for the surface
|
@@ -716,17 +716,18 @@ module BTAP
|
|
716
716
|
|
717
717
|
new_construction_set =vintage_construction_set.clone(model).to_DefaultConstructionSet.get
|
718
718
|
#Set conductances to needed values in construction set if possible.
|
719
|
-
BTAP::Resources::Envelope::ConstructionSets::customize_default_surface_construction_set_rsi!(
|
720
|
-
|
721
|
-
|
722
|
-
|
723
|
-
|
724
|
-
|
725
|
-
|
726
|
-
|
727
|
-
|
728
|
-
|
729
|
-
|
719
|
+
BTAP::Resources::Envelope::ConstructionSets::customize_default_surface_construction_set_rsi!(
|
720
|
+
model: model, name: "#{@default_construction_set}-modified",default_surface_construction_set: new_construction_set,
|
721
|
+
ext_wall_rsi: @ext_wall_rsi, ext_floor_rsi: @ext_floor_rsi, ext_roof_rsi: @ext_roof_rsi,
|
722
|
+
ground_wall_rsi: @ground_wall_rsi, ground_floor_rsi: @ground_floor_rsi, ground_roof_rsi: @ground_roof_rsi,
|
723
|
+
fixed_window_rsi: @fixed_window_rsi, fixed_wind_solar_trans: @fixed_wind_solar_trans, fixed_wind_vis_trans: @fixed_wind_vis_trans,
|
724
|
+
operable_window_rsi: @operable_window_rsi, operable_wind_solar_trans: @operable_wind_solar_trans, operable_wind_vis_trans: @operable_wind_vis_trans,
|
725
|
+
door_construction_rsi: @door_construction_rsi,
|
726
|
+
glass_door_rsi: @glass_door_rsi, glass_door_solar_trans: @glass_door_solar_trans, glass_door_vis_trans: @glass_door_vis_trans,
|
727
|
+
overhead_door_rsi: @overhead_door_rsi,
|
728
|
+
skylight_rsi: @skylight_rsi, skylight_solar_trans: @skylight_solar_trans, skylight_vis_trans: @skylight_vis_trans,
|
729
|
+
tubular_daylight_dome_rsi: @tubular_daylight_dome_rsi, tubular_daylight_dome_solar_trans: @tubular_daylight_dome_solar_trans, tubular_daylight_dome_vis_trans: @tubular_daylight_dome_vis_trans,
|
730
|
+
tubular_daylight_diffuser_rsi: @tubular_daylight_diffuser_rsi, tubular_daylight_diffuser_solar_trans: @tubular_daylight_diffuser_solar_trans, tubular_daylight_diffuser_vis_trans: @tubular_daylight_diffuser_vis_trans
|
730
731
|
)
|
731
732
|
|
732
733
|
|
@@ -747,12 +747,15 @@ module BTAP
|
|
747
747
|
end
|
748
748
|
return ruleset
|
749
749
|
end
|
750
|
+
|
750
751
|
def self.create_annual_fraction_ruleset_schedule(model,name,hourArrayValues)
|
751
752
|
self.create_annual_ruleset_schedule(model,name,"FRACTION",hourArrayValues)
|
752
753
|
end
|
754
|
+
|
753
755
|
def self.create_annual_on_off_ruleset_schedule(model,name,hourArrayValues)
|
754
756
|
self.create_annual_ruleset_schedule(model,name,"ON_OFF",hourArrayValues)
|
755
757
|
end
|
758
|
+
|
756
759
|
def self.create_annual_temperature_ruleset_schedule(model,name,hourArrayValues)
|
757
760
|
self.create_annual_ruleset_schedule(model,name,"TEMPERATURE",hourArrayValues)
|
758
761
|
end
|
@@ -858,18 +861,6 @@ module BTAP
|
|
858
861
|
# return ruleset
|
859
862
|
# end
|
860
863
|
|
861
|
-
def self.create_annual_fraction_ruleset_schedule(model,name,hourArrayValues)
|
862
|
-
self.create_annual_ruleset_schedule(model,name,"FRACTION",hourArrayValues)
|
863
|
-
end
|
864
|
-
|
865
|
-
def self.create_annual_on_off_ruleset_schedule(model,name,hourArrayValues)
|
866
|
-
self.create_annual_ruleset_schedule(model,name,"ON_OFF",hourArrayValues)
|
867
|
-
end
|
868
|
-
|
869
|
-
def self.create_annual_temperature_ruleset_schedule(model,name,hourArrayValues)
|
870
|
-
self.create_annual_ruleset_schedule(model,name,"TEMPERATURE",hourArrayValues)
|
871
|
-
end
|
872
|
-
|
873
864
|
|
874
865
|
|
875
866
|
# This method creates a new dual setpoint schedule using pre-created heating and cooling schedules.
|
@@ -0,0 +1,178 @@
|
|
1
|
+
|
2
|
+
# open the class to add methods to return sizing values
|
3
|
+
class OpenStudio::Model::AirLoopHVACUnitaryHeatPumpAirToAir
|
4
|
+
|
5
|
+
# Sets all auto-sizeable fields to autosize
|
6
|
+
def autosize
|
7
|
+
self.autosizeSupplyAirFlowRateDuringCoolingOperation
|
8
|
+
self.autosizeSupplyAirFlowRateDuringHeatingOperation
|
9
|
+
self.autosizeSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded
|
10
|
+
self.autosizeSpeed1SupplyAirFlowRateDuringCoolingOperation
|
11
|
+
self.autosizeSpeed1SupplyAirFlowRateDuringHeatingOperation
|
12
|
+
self.autosizeSpeed2SupplyAirFlowRateDuringCoolingOperation
|
13
|
+
self.autosizeSpeed2SupplyAirFlowRateDuringHeatingOperation
|
14
|
+
self.autosizeSpeed3SupplyAirFlowRateDuringCoolingOperation
|
15
|
+
self.autosizeSpeed3SupplyAirFlowRateDuringHeatingOperation
|
16
|
+
self.autosizeSpeed4SupplyAirFlowRateDuringCoolingOperation
|
17
|
+
self.autosizeSpeed4SupplyAirFlowRateDuringHeatingOperation
|
18
|
+
self.autosizeMaximumSupplyAirTemperaturefromSupplementalHeater
|
19
|
+
end
|
20
|
+
|
21
|
+
# Takes the values calculated by the EnergyPlus sizing routines
|
22
|
+
# and puts them into this object model in place of the autosized fields.
|
23
|
+
# Must have previously completed a run with sql output for this to work.
|
24
|
+
def applySizingValues
|
25
|
+
|
26
|
+
sup_air_flow_cooling = self.autosizedSupplyAirFlowRateDuringCoolingOperation
|
27
|
+
if sup_air_flow_cooling.is_initialized
|
28
|
+
self.setSupplyAirFlowRateDuringCoolingOperation(sup_air_flow_cooling.get)
|
29
|
+
end
|
30
|
+
|
31
|
+
sup_air_flow_heating = self.autosizedsSupplyAirFlowRateDuringHeatingOperation
|
32
|
+
if sup_air_flow_heating.is_initialized
|
33
|
+
self.setSupplyAirFlowRateDuringHeatingOperation(sup_air_flow_heating.get)
|
34
|
+
end
|
35
|
+
|
36
|
+
sup_air_flow_no_htg_clg = self.autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded
|
37
|
+
if sup_air_flow_no_htg_clg.is_initialized
|
38
|
+
self.setSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded(sup_air_flow_no_htg_clg.get)
|
39
|
+
end
|
40
|
+
|
41
|
+
speed1_sup_air_flow_cooling = self.autosizedSpeed1SupplyAirFlowRateDuringCoolingOperation
|
42
|
+
if speed1_sup_air_flow_cooling.is_initialized
|
43
|
+
self.setSpeed1SupplyAirFlowRateDuringCoolingOperation(speed1_sup_air_flow_cooling.get)
|
44
|
+
end
|
45
|
+
|
46
|
+
speed1_sup_air_flow_heating = self.autosizedsSpeed1SupplyAirFlowRateDuringHeatingOperation
|
47
|
+
if speed1_sup_air_flow_heating.is_initialized
|
48
|
+
self.setSpeed1SupplyAirFlowRateDuringHeatingOperation(speed1_sup_air_flow_heating.get)
|
49
|
+
end
|
50
|
+
|
51
|
+
speed2_sup_air_flow_cooling = self.autosizedSpeed2SupplyAirFlowRateDuringCoolingOperation
|
52
|
+
if speed2_sup_air_flow_cooling.is_initialized
|
53
|
+
self.setSpeed2SupplyAirFlowRateDuringCoolingOperation(speed2_sup_air_flow_cooling.get)
|
54
|
+
end
|
55
|
+
|
56
|
+
speed2_sup_air_flow_heating = self.autosizedsSpeed2SupplyAirFlowRateDuringHeatingOperation
|
57
|
+
if speed2_sup_air_flow_heating.is_initialized
|
58
|
+
self.setSpeed2SupplyAirFlowRateDuringHeatingOperation(speed2_sup_air_flow_heating.get)
|
59
|
+
end
|
60
|
+
|
61
|
+
speed3_sup_air_flow_cooling = self.autosizedSpeed3SupplyAirFlowRateDuringCoolingOperation
|
62
|
+
if speed1_sup_air_flow_cooling.is_initialized
|
63
|
+
self.setSpeed3SupplyAirFlowRateDuringCoolingOperation(speed3_sup_air_flow_cooling.get)
|
64
|
+
end
|
65
|
+
|
66
|
+
speed3_sup_air_flow_heating = self.autosizedsSpeed3SupplyAirFlowRateDuringHeatingOperation
|
67
|
+
if speed3_sup_air_flow_heating.is_initialized
|
68
|
+
self.setSpeed3SupplyAirFlowRateDuringHeatingOperation(speed3_sup_air_flow_heating.get)
|
69
|
+
end
|
70
|
+
|
71
|
+
speed3_sup_air_flow_no_htg_clg = self.autosizedSpeed3SupplyAirFlowRateWhenNoCoolingorHeatingisNeeded
|
72
|
+
if speed3_sup_air_flow_no_htg_clg.is_initialized
|
73
|
+
self.setSpeed3SupplyAirFlowRateWhenNoCoolingorHeatingisNeeded(speed3_sup_air_flow_no_htg_clg.get)
|
74
|
+
end
|
75
|
+
|
76
|
+
speed4_sup_air_flow_cooling = self.autosizedSpeed4SupplyAirFlowRateDuringCoolingOperation
|
77
|
+
if speed4_sup_air_flow_cooling.is_initialized
|
78
|
+
self.setSpeed4SupplyAirFlowRateDuringCoolingOperation(speed4_sup_air_flow_cooling.get)
|
79
|
+
end
|
80
|
+
|
81
|
+
speed4_sup_air_flow_heating = self.autosizedsSpeed4SupplyAirFlowRateDuringHeatingOperation
|
82
|
+
if speed4_sup_air_flow_heating.is_initialized
|
83
|
+
self.setSpeed4SupplyAirFlowRateDuringHeatingOperation(speed4_sup_air_flow_heating.get)
|
84
|
+
end
|
85
|
+
|
86
|
+
max_sup_htg_temp = self.autosizedMaximumSupplyAirTemperaturefromSupplementalHeater
|
87
|
+
if max_sup_htg_temp.is_initialized
|
88
|
+
self.setMaximumSupplyAirTemperaturefromSupplementalHeater(max_sup_htg_temp.get)
|
89
|
+
end
|
90
|
+
|
91
|
+
end
|
92
|
+
|
93
|
+
# returns the autosized supply air flow rate during cooling operation as an optional double
|
94
|
+
def autosizedSupplyAirFlowRateDuringCoolingOperation
|
95
|
+
|
96
|
+
return self.model.getAutosizedValue(self, 'Supply Air Flow Rate During Heating Operation', 'm3/s')
|
97
|
+
|
98
|
+
end
|
99
|
+
|
100
|
+
# returns the autosized supply air flow rate during heating operation as an optional double
|
101
|
+
def autosizedSupplyAirFlowRateDuringHeatingOperation
|
102
|
+
|
103
|
+
return self.model.getAutosizedValue(self, 'Supply Air Flow Rate During Cooling Operation', 'm3/s')
|
104
|
+
|
105
|
+
end
|
106
|
+
|
107
|
+
# returns the autosized supply air flow rate when no heating or cooling is needed as an optional double
|
108
|
+
def autosizedSupplyAirFlowRateWhenNoCoolingorHeatingisNeeded
|
109
|
+
|
110
|
+
return self.model.getAutosizedValue(self, 'Supply Air Flow Rate', 'm3/s')
|
111
|
+
|
112
|
+
end
|
113
|
+
|
114
|
+
# returns the autosized supply air flow rate during cooling operation as an optional double
|
115
|
+
def autosizedSpeed1SupplyAirFlowRateDuringCoolingOperation
|
116
|
+
|
117
|
+
return self.model.getAutosizedValue(self, 'Speed 1 Supply Air Flow Rate During Heating Operation', 'm3/s')
|
118
|
+
|
119
|
+
end
|
120
|
+
|
121
|
+
# returns the autosized supply air flow rate during heating operation as an optional double
|
122
|
+
def autosizedSpeed1SupplyAirFlowRateDuringHeatingOperation
|
123
|
+
|
124
|
+
return self.model.getAutosizedValue(self, 'Speed 1 Supply Air Flow Rate During Cooling Operation', 'm3/s')
|
125
|
+
|
126
|
+
end
|
127
|
+
|
128
|
+
# returns the autosized supply air flow rate during cooling operation as an optional double
|
129
|
+
def autosizedSpeed2SupplyAirFlowRateDuringCoolingOperation
|
130
|
+
|
131
|
+
return self.model.getAutosizedValue(self, 'Speed 2 Supply Air Flow Rate During Heating Operation', 'm3/s')
|
132
|
+
|
133
|
+
end
|
134
|
+
|
135
|
+
# returns the autosized supply air flow rate during heating operation as an optional double
|
136
|
+
def autosizedSpeed2SupplyAirFlowRateDuringHeatingOperation
|
137
|
+
|
138
|
+
return self.model.getAutosizedValue(self, 'Speed 2 Supply Air Flow Rate During Cooling Operation', 'm3/s')
|
139
|
+
|
140
|
+
end
|
141
|
+
|
142
|
+
# returns the autosized supply air flow rate during cooling operation as an optional double
|
143
|
+
def autosizedSpeed3SupplyAirFlowRateDuringCoolingOperation
|
144
|
+
|
145
|
+
return self.model.getAutosizedValue(self, 'Speed 3 Supply Air Flow Rate During Heating Operation', 'm3/s')
|
146
|
+
|
147
|
+
end
|
148
|
+
|
149
|
+
# returns the autosized supply air flow rate during heating operation as an optional double
|
150
|
+
def autosizedSpeed3SupplyAirFlowRateDuringHeatingOperation
|
151
|
+
|
152
|
+
return self.model.getAutosizedValue(self, 'Speed 3 Supply Air Flow Rate During Cooling Operation', 'm3/s')
|
153
|
+
|
154
|
+
end
|
155
|
+
|
156
|
+
# returns the autosized supply air flow rate during cooling operation as an optional double
|
157
|
+
def autosizedSpeed4SupplyAirFlowRateDuringCoolingOperation
|
158
|
+
|
159
|
+
return self.model.getAutosizedValue(self, 'Speed 4 Supply Air Flow Rate During Heating Operation', 'm3/s')
|
160
|
+
|
161
|
+
end
|
162
|
+
|
163
|
+
# returns the autosized supply air flow rate during heating operation as an optional double
|
164
|
+
def autosizedSpeed4SupplyAirFlowRateDuringHeatingOperation
|
165
|
+
|
166
|
+
return self.model.getAutosizedValue(self, 'Speed 4 Supply Air Flow Rate During Cooling Operation', 'm3/s')
|
167
|
+
|
168
|
+
end
|
169
|
+
|
170
|
+
# returns the autosized maximum supply air temperature from supplemental heater as an optional double
|
171
|
+
def autosizedMaximumSupplyAirTemperaturefromSupplementalHeater
|
172
|
+
|
173
|
+
return self.model.getAutosizedValue(self, 'Maximum Supply Air Temperature from Supplemental Heater', 'C')
|
174
|
+
|
175
|
+
end
|
176
|
+
|
177
|
+
|
178
|
+
end
|
@@ -88,56 +88,56 @@ class OpenStudio::Model::CoilCoolingDXMultiSpeed
|
|
88
88
|
# returns the autosized rated total cooling capacity for stage 1 as an optional double
|
89
89
|
def autosizedSpeed1GrossRatedTotalCoolingCapacity
|
90
90
|
|
91
|
-
return self.model.getAutosizedValue(self,'Speed 1
|
91
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 1 Gross Rated Total Cooling Capacity', 'W')
|
92
92
|
|
93
93
|
end
|
94
94
|
|
95
95
|
# returns the autosized rated total cooling capacity for stage 2 as an optional double
|
96
96
|
def autosizedSpeed2GrossRatedTotalCoolingCapacity
|
97
97
|
|
98
|
-
return self.model.getAutosizedValue(self,'Speed 2
|
98
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 2 Gross Rated Total Cooling Capacity', 'W')
|
99
99
|
|
100
100
|
end
|
101
101
|
|
102
102
|
# returns the autosized rated total cooling capacity for stage 3 as an optional double
|
103
103
|
def autosizedSpeed3GrossRatedTotalCoolingCapacity
|
104
104
|
|
105
|
-
return self.model.getAutosizedValue(self,'Speed 3
|
105
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 3 Gross Rated Total Cooling Capacity', 'W')
|
106
106
|
|
107
107
|
end
|
108
108
|
|
109
109
|
# returns the autosized rated total cooling capacity for stage 4 as an optional double
|
110
110
|
def autosizedSpeed4GrossRatedTotalCoolingCapacity
|
111
111
|
|
112
|
-
return self.model.getAutosizedValue(self,'Speed 4
|
112
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 4 Gross Rated Total Cooling Capacity', 'W')
|
113
113
|
|
114
114
|
end
|
115
115
|
|
116
116
|
# returns the autosized rated sensible heat ratio for stage 1 as an optional double
|
117
117
|
def autosizedSpeed1RatedSensibleHeatRatio
|
118
118
|
|
119
|
-
return self.model.getAutosizedValue(self,'Speed 1
|
119
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 1 Rated Sensible Heat Ratio', '')
|
120
120
|
|
121
121
|
end
|
122
122
|
|
123
123
|
# returns the autosized rated sensible heat ratio for stage 2 as an optional double
|
124
124
|
def autosizedSpeed2RatedSensibleHeatRatio
|
125
125
|
|
126
|
-
return self.model.getAutosizedValue(self,'Speed 2
|
126
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 2 Rated Sensible Heat Ratio', '')
|
127
127
|
|
128
128
|
end
|
129
129
|
|
130
130
|
# returns the autosized rated sensible heat ratio for stage 3 as an optional double
|
131
131
|
def autosizedSpeed3RatedSensibleHeatRatio
|
132
132
|
|
133
|
-
return self.model.getAutosizedValue(self,'Speed 3
|
133
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 3 Rated Sensible Heat Ratio', '')
|
134
134
|
|
135
135
|
end
|
136
136
|
|
137
137
|
# returns the autosized rated sensible heat ratio for stage 4 as an optional double
|
138
138
|
def autosizedSpeed4RatedSensibleHeatRatio
|
139
139
|
|
140
|
-
return self.model.getAutosizedValue(self,'Speed 4
|
140
|
+
return self.model.getAutosizedValue(self,'Design Size Speed 4 Rated Sensible Heat Ratio', '')
|
141
141
|
|
142
142
|
end
|
143
143
|
|
@@ -17,16 +17,19 @@ class OpenStudio::Model::Model
|
|
17
17
|
require_relative 'Siz.AirTermSnglDuctUncontrolled'
|
18
18
|
require_relative 'Siz.AirLoopHVAC'
|
19
19
|
require_relative 'Siz.AirLoopHVACUnitaryHeatPumpAirToAir'
|
20
|
+
require_relative 'Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed'
|
20
21
|
require_relative 'Siz.FanConstantVolume'
|
21
22
|
require_relative 'Siz.FanVariableVolume'
|
22
23
|
require_relative 'Siz.FanOnOff'
|
23
24
|
require_relative 'Siz.CoilHeatingElectric'
|
24
25
|
require_relative 'Siz.CoilHeatingGas'
|
26
|
+
require_relative 'Siz.CoilHeatingGasMultiStage'
|
25
27
|
require_relative 'Siz.CoilHeatingWater'
|
26
28
|
require_relative 'Siz.CoilHeatingDXSingleSpeed'
|
27
29
|
require_relative 'Siz.CoilHeatingDXMultiSpeed'
|
28
30
|
require_relative 'Siz.CoilHeatingWaterToAirHeatPumpEquationFit'
|
29
31
|
require_relative 'Siz.CoilCoolingWaterToAirHeatPumpEquationFit'
|
32
|
+
require_relative 'Siz.CoilCoolingDXMultiSpeed'
|
30
33
|
require_relative 'Siz.CoilCoolingDXSingleSpeed'
|
31
34
|
require_relative 'Siz.CoilCoolingDXTwoSpeed'
|
32
35
|
require_relative 'Siz.CoilCoolingWater'
|
@@ -0,0 +1,28 @@
|
|
1
|
+
class ASHRAE9012004 < ASHRAE901
|
2
|
+
# @!group Pump
|
3
|
+
|
4
|
+
# Determine type of pump part load control type
|
5
|
+
#
|
6
|
+
# @code_sections [90.1-2004_6.5.4.1]
|
7
|
+
# @param pump [OpenStudio::Model::PumpVariableSpeed] OpenStudio pump object
|
8
|
+
# @param plant_loop_type [String] Type of plant loop
|
9
|
+
# @param pump_nominal_hp [Float] Pump nominal horsepower
|
10
|
+
# @return [String] Pump part load control type
|
11
|
+
def pump_variable_speed_get_control_type(pump, plant_loop_type, pump_nominal_hp)
|
12
|
+
threshold = 50 # hp
|
13
|
+
|
14
|
+
# Sizing factor to take into account that pumps
|
15
|
+
# are typically sized to handle a ~10% pressure
|
16
|
+
# increase and ~10% flow increase.
|
17
|
+
design_sizing_factor = 1.25
|
18
|
+
|
19
|
+
# Get pump head in Pa
|
20
|
+
pump_head_pa = pump.ratedPumpHead
|
21
|
+
|
22
|
+
if pump_nominal_hp * design_sizing_factor > threshold && pump_head_pa > 300_000 # 100 ft. of head
|
23
|
+
return 'VSD No Reset'
|
24
|
+
else
|
25
|
+
return 'Riding Curve'
|
26
|
+
end
|
27
|
+
end
|
28
|
+
end
|
@@ -0,0 +1,28 @@
|
|
1
|
+
class ASHRAE9012007 < ASHRAE901
|
2
|
+
# @!group Pump
|
3
|
+
|
4
|
+
# Determine type of pump part load control type
|
5
|
+
#
|
6
|
+
# @code_sections [90.1-2007_6.5.4.1]
|
7
|
+
# @param pump [OpenStudio::Model::PumpVariableSpeed] OpenStudio pump object
|
8
|
+
# @param plant_loop_type [String] Type of plant loop
|
9
|
+
# @param pump_nominal_hp [Float] Pump nominal horsepower
|
10
|
+
# @return [String] Pump part load control type
|
11
|
+
def pump_variable_speed_get_control_type(pump, plant_loop_type, pump_nominal_hp)
|
12
|
+
threshold = 50 # hp
|
13
|
+
|
14
|
+
# Sizing factor to take into account that pumps
|
15
|
+
# are typically sized to handle a ~10% pressure
|
16
|
+
# increase and ~10% flow increase.
|
17
|
+
design_sizing_factor = 1.25
|
18
|
+
|
19
|
+
# Get pump head in Pa
|
20
|
+
pump_head_pa = pump.ratedPumpHead
|
21
|
+
|
22
|
+
if pump_nominal_hp * design_sizing_factor > threshold && pump_head_pa > 300_000 # 100 ft. of head
|
23
|
+
return 'VSD No Reset'
|
24
|
+
else
|
25
|
+
return 'Riding Curve'
|
26
|
+
end
|
27
|
+
end
|
28
|
+
end
|
data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb
CHANGED
@@ -16,10 +16,12 @@ class ASHRAE9012010 < ASHRAE901
|
|
16
16
|
# 'DifferentialDryBulbAndEnthalpy'
|
17
17
|
def model_economizer_type(model, climate_zone)
|
18
18
|
economizer_type = case climate_zone
|
19
|
-
when 'ASHRAE 169-2006-
|
19
|
+
when 'ASHRAE 169-2006-0A',
|
20
|
+
'ASHRAE 169-2006-1A',
|
20
21
|
'ASHRAE 169-2006-2A',
|
21
22
|
'ASHRAE 169-2006-3A',
|
22
23
|
'ASHRAE 169-2006-4A',
|
24
|
+
'ASHRAE 169-2013-0A',
|
23
25
|
'ASHRAE 169-2013-1A',
|
24
26
|
'ASHRAE 169-2013-2A',
|
25
27
|
'ASHRAE 169-2013-3A',
|
@@ -30,4 +32,53 @@ class ASHRAE9012010 < ASHRAE901
|
|
30
32
|
end
|
31
33
|
return economizer_type
|
32
34
|
end
|
33
|
-
|
35
|
+
|
36
|
+
# Adjust model to comply with fenestration orientation requirements
|
37
|
+
#
|
38
|
+
# @code_sections [90.1-2010_5.5.4.5]
|
39
|
+
# @param [OpenStudio::Model::Model] OpenStudio model object
|
40
|
+
# @return [Boolean] Returns true if successful, false otherwise
|
41
|
+
def model_fenestration_orientation(model, climate_zone)
|
42
|
+
wwr = false
|
43
|
+
|
44
|
+
win_area_w = model_get_window_area_info_for_orientation(model, 'W', wwr: wwr)
|
45
|
+
win_area_e = model_get_window_area_info_for_orientation(model, 'E', wwr: wwr)
|
46
|
+
win_area_s = model_get_window_area_info_for_orientation(model, 'S', wwr: wwr)
|
47
|
+
|
48
|
+
# Make prototype specific adjustment to meet the code requirement
|
49
|
+
if !((win_area_s > win_area_w) && (win_area_s > win_area_e))
|
50
|
+
if model.getBuilding.standardsBuildingType.is_initialized
|
51
|
+
building_type = model.getBuilding.standardsBuildingType.get
|
52
|
+
|
53
|
+
case building_type
|
54
|
+
# TODO: Implementatation for other building types not meeting the requirement
|
55
|
+
# The offices, schools, warehouse (exempted), large hotel, outpatient,
|
56
|
+
# retails, apartments should meet the requirement according to Section
|
57
|
+
# 5.2.1.7 in Thornton et al. 2011
|
58
|
+
when 'Hospital'
|
59
|
+
# Rotate the building counter-clockwise
|
60
|
+
model_set_building_north_axis(model, 270.0)
|
61
|
+
when 'SmallHotel'
|
62
|
+
# Rotate the building clockwise
|
63
|
+
model_set_building_north_axis(model, 180.0)
|
64
|
+
else
|
65
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.model.ashrae_90_1_2010', "The prototype model doesn't meet the requirement from Section 5.5.4.5 in ASHRAE Standard 90.1-2010.")
|
66
|
+
end
|
67
|
+
else
|
68
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.model.ashrae_90_1_2010', "The prototype model doesn't meet the requirement from Section 5.5.4.5 in ASHRAE Standard 90.1-2010, its standards building type shall be specified.")
|
69
|
+
end
|
70
|
+
end
|
71
|
+
|
72
|
+
return true
|
73
|
+
end
|
74
|
+
|
75
|
+
# Is transfer air required?
|
76
|
+
#
|
77
|
+
# @code_sections [90.1-2010_6.5.7.1.2]
|
78
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
79
|
+
# @return [Boolean] true if transfer air is required, false otherwise
|
80
|
+
def model_transfer_air_required?(model)
|
81
|
+
# TODO: It actually is for kitchen but not implemented yet
|
82
|
+
return false
|
83
|
+
end
|
84
|
+
end
|