openstudio-standards 0.2.12.rc4 → 0.2.13.rc3
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
- data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
- data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
- data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
- data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
- data/data/geometry/ASHRAECourthouse.json +112 -0
- data/data/geometry/ASHRAECourthouse.osm +26470 -0
- data/data/geometry/ASHRAELargeHotel.osm +11 -1
- data/data/geometry/ASHRAELargeOffice.json +4 -0
- data/data/geometry/ASHRAESmallDataCenter.json +1 -1
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/exclude_list.csv +19 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/manage_OpenStudio_Standards.rb +87 -37
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +191 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +17 -0
- data/data/standards/test_performance_expected_dd_results.csv +1971 -1171
- data/lib/openstudio-standards.rb +76 -18
- data/lib/openstudio-standards/btap/btap.model.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +14 -11
- data/lib/openstudio-standards/btap/envelope.rb +185 -257
- data/lib/openstudio-standards/btap/fileio.rb +1 -0
- data/lib/openstudio-standards/btap/geometry.rb +21 -1
- data/lib/openstudio-standards/btap/measures.rb +12 -11
- data/lib/openstudio-standards/btap/schedules.rb +3 -12
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.rb +178 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXMultiSpeed.rb +8 -8
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +3 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +23 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +230 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +575 -345
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +142 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/refs/references.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +70 -51
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +91 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +30 -9
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +37 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
- data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +305 -247
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
- data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
- data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
- data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +76 -25
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +85 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +70 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +105 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +104 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +32 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +112 -25
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +37 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +125 -41
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +172 -55
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1662 -332
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +4994 -234
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +5967 -2727
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +5920 -2700
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +2011 -1112
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +1946 -1106
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
- data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
- data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +2 -18
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +87 -15
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +31 -19
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/curves.json +75 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -16
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +913 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/equip_eff_lim.json +52 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +109 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +23 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +803 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +787 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +100 -0
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +33 -0
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1729 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +68 -33
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +24 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +110 -99
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +24 -24
- data/lib/openstudio-standards/standards/necb/NECB2011/data/curves.json +50 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +31 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/led_lighting_data.json +2028 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1745 -1297
- data/lib/openstudio-standards/standards/necb/NECB2011/daylighting_control.md +70 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/demand_controlled_ventilation.md +46 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +69 -107
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +41 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +139 -141
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +38 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +492 -240
- data/lib/openstudio-standards/standards/necb/NECB2011/led_lighting.md +51 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +75 -9
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +1229 -37
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +11 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +32 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +29 -0
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
- data/lib/openstudio-standards/standards/standard.rb +6 -5
- data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
- data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
- data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
- data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
- data/lib/openstudio-standards/utilities/logging.rb +7 -7
- data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
- data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
- data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
- data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
- data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
- data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
- data/lib/openstudio-standards/utilities/simulation.rb +13 -21
- data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
- data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
- data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
- data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
- data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
- data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +112 -87
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
- metadata +236 -2
data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb
CHANGED
@@ -1,4 +1,3 @@
|
|
1
|
-
|
2
1
|
# Custom changes for the QuickServiceRestaurant prototype.
|
3
2
|
# These are changes that are inconsistent with other prototype
|
4
3
|
# building types.
|
@@ -28,31 +27,37 @@ module QuickServiceRestaurant
|
|
28
27
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Adjusting daylight sensor positions and fractions')
|
29
28
|
|
30
29
|
adjustments = [
|
31
|
-
|
32
|
-
|
33
|
-
|
34
|
-
|
35
|
-
|
36
|
-
|
37
|
-
|
38
|
-
|
39
|
-
|
40
|
-
|
41
|
-
|
42
|
-
|
43
|
-
|
44
|
-
|
30
|
+
{ '90.1-2010' => { 'Dining' => { 'sensor_1_frac' => 0.22,
|
31
|
+
'sensor_2_frac' => 0.22,
|
32
|
+
'sensor_1_xyz' => [1.9812, 1.9812, 0.762],
|
33
|
+
'sensor_2_xyz' => [13.2588, 1.9812, 0.762] } },
|
34
|
+
'90.1-2013' => { 'Dining' => { 'sensor_1_frac' => 0.38,
|
35
|
+
'sensor_2_frac' => 0.38,
|
36
|
+
'sensor_1_xyz' => [2.6548, 2.6548, 0.762],
|
37
|
+
'sensor_2_xyz' => [12.588, 2.6548, 0.762] } },
|
38
|
+
'90.1-2016' => { 'Dining' => { 'sensor_1_frac' => 0.38,
|
39
|
+
'sensor_2_frac' => 0.38,
|
40
|
+
'sensor_1_xyz' => [2.6548, 2.6548, 0.762],
|
41
|
+
'sensor_2_xyz' => [12.588, 2.6548, 0.762] } },
|
42
|
+
'90.1-2019' => { 'Dining' => { 'sensor_1_frac' => 0.38,
|
43
|
+
'sensor_2_frac' => 0.38,
|
44
|
+
'sensor_1_xyz' => [2.6548, 2.6548, 0.762],
|
45
|
+
'sensor_2_xyz' => [12.588, 2.6548, 0.762] } } }
|
46
|
+
]
|
45
47
|
|
46
48
|
# Adjust daylight sensors in each space
|
47
49
|
model.getSpaces.each do |space|
|
48
|
-
if adjustments[0].keys.include?
|
49
|
-
if adjustments[0][template].keys.include?
|
50
|
+
if adjustments[0].keys.include? template
|
51
|
+
if adjustments[0][template].keys.include? space.name.to_s
|
50
52
|
adj = adjustments[0][template][space.name.to_s]
|
51
53
|
next if space.thermalZone.empty?
|
54
|
+
|
52
55
|
zone = space.thermalZone.get
|
53
56
|
next if space.spaceType.empty?
|
57
|
+
|
54
58
|
spc_type = space.spaceType.get
|
55
59
|
next if spc_type.standardsSpaceType.empty?
|
60
|
+
|
56
61
|
stds_spc_type = spc_type.standardsSpaceType.get
|
57
62
|
# Adjust the primary sensor
|
58
63
|
if adj['sensor_1_frac'] && zone.primaryDaylightingControl.is_initialized
|
@@ -106,7 +111,8 @@ module QuickServiceRestaurant
|
|
106
111
|
infiltration_diningdoor.setSchedule(model_add_schedule(model, 'RestaurantFastFood DOOR_INFIL_SCH'))
|
107
112
|
elsif template == '90.1-2007'
|
108
113
|
case climate_zone
|
109
|
-
when 'ASHRAE 169-2006-
|
114
|
+
when 'ASHRAE 169-2006-0A',
|
115
|
+
'ASHRAE 169-2006-1A',
|
110
116
|
'ASHRAE 169-2006-2A',
|
111
117
|
'ASHRAE 169-2006-2B',
|
112
118
|
'ASHRAE 169-2006-3A',
|
@@ -115,6 +121,7 @@ module QuickServiceRestaurant
|
|
115
121
|
'ASHRAE 169-2006-4A',
|
116
122
|
'ASHRAE 169-2006-4B',
|
117
123
|
'ASHRAE 169-2006-4C',
|
124
|
+
'ASHRAE 169-2013-0A',
|
118
125
|
'ASHRAE 169-2013-1A',
|
119
126
|
'ASHRAE 169-2013-2A',
|
120
127
|
'ASHRAE 169-2013-2B',
|
@@ -130,14 +137,16 @@ module QuickServiceRestaurant
|
|
130
137
|
infiltration_per_zone_diningdoor = 0.583798439
|
131
138
|
infiltration_diningdoor.setSchedule(model_add_schedule(model, 'RestaurantFastFood VESTIBULE_DOOR_INFIL_SCH'))
|
132
139
|
end
|
133
|
-
elsif template == '90.1-2010' || template == '90.1-2013'
|
140
|
+
elsif template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
|
134
141
|
case climate_zone
|
135
|
-
when 'ASHRAE 169-2006-
|
142
|
+
when 'ASHRAE 169-2006-0A',
|
143
|
+
'ASHRAE 169-2006-1A',
|
136
144
|
'ASHRAE 169-2006-2A',
|
137
145
|
'ASHRAE 169-2006-2B',
|
138
146
|
'ASHRAE 169-2006-3A',
|
139
147
|
'ASHRAE 169-2006-3B',
|
140
148
|
'ASHRAE 169-2006-3C',
|
149
|
+
'ASHRAE 169-2013-0A',
|
141
150
|
'ASHRAE 169-2013-1A',
|
142
151
|
'ASHRAE 169-2013-2A',
|
143
152
|
'ASHRAE 169-2013-2B',
|
@@ -169,14 +178,14 @@ module QuickServiceRestaurant
|
|
169
178
|
elec_equip_def1.setName('Kitchen Electric Equipment Definition1')
|
170
179
|
elec_equip_def2.setName('Kitchen Electric Equipment Definition2')
|
171
180
|
case template
|
172
|
-
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
|
181
|
+
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
173
182
|
elec_equip_def1.setFractionLatent(0)
|
174
183
|
elec_equip_def1.setFractionRadiant(0.25)
|
175
184
|
elec_equip_def1.setFractionLost(0)
|
176
185
|
elec_equip_def2.setFractionLatent(0)
|
177
186
|
elec_equip_def2.setFractionRadiant(0.25)
|
178
187
|
elec_equip_def2.setFractionLost(0)
|
179
|
-
if template == '90.1-2013'
|
188
|
+
if template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
|
180
189
|
elec_equip_def1.setDesignLevel(457.5)
|
181
190
|
elec_equip_def2.setDesignLevel(570)
|
182
191
|
else
|
@@ -207,7 +216,7 @@ module QuickServiceRestaurant
|
|
207
216
|
|
208
217
|
def update_sizing_zone(model)
|
209
218
|
case template
|
210
|
-
when '90.1-2007', '90.1-2010', '90.1-2013'
|
219
|
+
when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
211
220
|
zone_sizing = model.getSpaceByName('Dining').get.thermalZone.get.sizingZone
|
212
221
|
zone_sizing.setCoolingDesignAirFlowMethod('DesignDayWithLimit')
|
213
222
|
zone_sizing.setCoolingMinimumAirFlowperZoneFloorArea(0.003581176)
|
@@ -232,9 +241,11 @@ module QuickServiceRestaurant
|
|
232
241
|
case template
|
233
242
|
when '90.1-2004', '90.1-2007', '90.1-2010'
|
234
243
|
case climate_zone
|
235
|
-
when 'ASHRAE 169-2006-
|
244
|
+
when 'ASHRAE 169-2006-0B',
|
245
|
+
'ASHRAE 169-2006-1B',
|
236
246
|
'ASHRAE 169-2006-2B',
|
237
247
|
'ASHRAE 169-2006-3B',
|
248
|
+
'ASHRAE 169-2013-0B',
|
238
249
|
'ASHRAE 169-2013-1B',
|
239
250
|
'ASHRAE 169-2013-2B',
|
240
251
|
'ASHRAE 169-2013-3B'
|
@@ -258,7 +269,7 @@ module QuickServiceRestaurant
|
|
258
269
|
ventilation.setOutdoorAirFlowperPerson(0)
|
259
270
|
ventilation.setOutdoorAirFlowperFloorArea(0)
|
260
271
|
case template
|
261
|
-
when '90.1-2007', '90.1-2010', '90.1-2013'
|
272
|
+
when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
262
273
|
ventilation.setOutdoorAirFlowRate(1.14135966)
|
263
274
|
when '90.1-2004', 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
|
264
275
|
ventilation.setOutdoorAirFlowRate(0.7312)
|
@@ -267,7 +278,7 @@ module QuickServiceRestaurant
|
|
267
278
|
|
268
279
|
def model_update_exhaust_fan_efficiency(model)
|
269
280
|
case template
|
270
|
-
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
|
281
|
+
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
271
282
|
model.getFanZoneExhausts.sort.each do |exhaust_fan|
|
272
283
|
fan_name = exhaust_fan.name.to_s
|
273
284
|
if fan_name.include? 'Dining'
|
@@ -285,6 +296,9 @@ module QuickServiceRestaurant
|
|
285
296
|
|
286
297
|
def add_zone_mixing(model)
|
287
298
|
# add zone_mixing between kitchen and dining
|
299
|
+
# TODO: remove zone mixing objects,
|
300
|
+
# transfer air is the should be the same for
|
301
|
+
# all stds, exhaust flow varies
|
288
302
|
space_kitchen = model.getSpaceByName('Kitchen').get
|
289
303
|
zone_kitchen = space_kitchen.thermalZone.get
|
290
304
|
space_dining = model.getSpaceByName('Dining').get
|
@@ -294,7 +308,7 @@ module QuickServiceRestaurant
|
|
294
308
|
case template
|
295
309
|
when 'DOE Ref Pre-1980', 'DOE Ref 1980-2004'
|
296
310
|
zone_mixing_kitchen.setDesignFlowRate(0.834532374)
|
297
|
-
when '90.1-2007', '90.1-2010', '90.1-2013'
|
311
|
+
when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
298
312
|
zone_mixing_kitchen.setDesignFlowRate(0.416067345)
|
299
313
|
when '90.1-2004'
|
300
314
|
zone_mixing_kitchen.setDesignFlowRate(0.826232888)
|
@@ -304,11 +318,12 @@ module QuickServiceRestaurant
|
|
304
318
|
end
|
305
319
|
|
306
320
|
def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
|
307
|
-
|
308
321
|
return true
|
309
322
|
end
|
310
323
|
|
311
324
|
def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
|
325
|
+
# Set original building North axis
|
326
|
+
model_set_building_north_axis(model, 0.0)
|
312
327
|
|
313
328
|
return true
|
314
329
|
end
|
@@ -1,4 +1,3 @@
|
|
1
|
-
|
2
1
|
# Custom changes for the RetailStandalone prototype.
|
3
2
|
# These are changes that are inconsistent with other prototype
|
4
3
|
# building types.
|
@@ -11,7 +10,7 @@ module RetailStandalone
|
|
11
10
|
def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model)
|
12
11
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments')
|
13
12
|
|
14
|
-
# Add the door infiltration for template 2004,2007,2010,2013
|
13
|
+
# Add the door infiltration for template 2004,2007,2010,2013,2016,2019
|
15
14
|
case template
|
16
15
|
when '90.1-2004'
|
17
16
|
entry_space = model.getSpaceByName('Front_Entry').get
|
@@ -23,16 +22,20 @@ module RetailStandalone
|
|
23
22
|
infiltration_entry.setSpace(entry_space)
|
24
23
|
|
25
24
|
# temporal solution for CZ dependent door infiltration rate. In fact other standards need similar change as well
|
26
|
-
when '90.1-2007', '90.1-2010', '90.1-2013'
|
25
|
+
when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
27
26
|
entry_space = model.getSpaceByName('Front_Entry').get
|
28
27
|
infiltration_entry = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
29
28
|
infiltration_entry.setName('Entry door Infiltration')
|
30
29
|
case climate_zone
|
31
|
-
when 'ASHRAE 169-2006-
|
30
|
+
when 'ASHRAE 169-2006-0A',
|
31
|
+
'ASHRAE 169-2006-1A',
|
32
|
+
'ASHRAE 169-2006-0B',
|
32
33
|
'ASHRAE 169-2006-1B',
|
33
34
|
'ASHRAE 169-2006-2A',
|
34
35
|
'ASHRAE 169-2006-2B',
|
36
|
+
'ASHRAE 169-2013-0A',
|
35
37
|
'ASHRAE 169-2013-1A',
|
38
|
+
'ASHRAE 169-2013-0B',
|
36
39
|
'ASHRAE 169-2013-1B',
|
37
40
|
'ASHRAE 169-2013-2A',
|
38
41
|
'ASHRAE 169-2013-2B'
|
@@ -55,14 +58,14 @@ module RetailStandalone
|
|
55
58
|
end
|
56
59
|
|
57
60
|
case template
|
58
|
-
when '90.1-2013'
|
61
|
+
when '90.1-2013', '90.1-2016', '90.1-2019'
|
59
62
|
# Add EMS for controlling the system serving the front entry zone
|
60
63
|
oa_sens = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Site Outdoor Air Drybulb Temperature')
|
61
64
|
oa_sens.setName('OAT_F')
|
62
65
|
oa_sens.setKeyName('Environment')
|
63
66
|
|
64
67
|
model.getFanConstantVolumes.each do |fan|
|
65
|
-
if fan.name.to_s.include?
|
68
|
+
if fan.name.to_s.include?('Front') && fan.name.to_s.include?('Entry')
|
66
69
|
frt_entry_avail_fan_sch = fan.availabilitySchedule
|
67
70
|
frt_entry_fan = OpenStudio::Model::EnergyManagementSystemActuator.new(frt_entry_avail_fan_sch, 'Schedule:Year', 'Schedule Value')
|
68
71
|
frt_entry_fan.setName('FrontEntry_Fan')
|
@@ -70,7 +73,7 @@ module RetailStandalone
|
|
70
73
|
end
|
71
74
|
|
72
75
|
model.getCoilHeatingGass.each do |coil|
|
73
|
-
if coil.name.to_s.include?
|
76
|
+
if coil.name.to_s.include?('Front') && coil.name.to_s.include?('Entry')
|
74
77
|
frt_entry_avail_coil_sch = coil.availabilitySchedule
|
75
78
|
frt_entry_coil = OpenStudio::Model::EnergyManagementSystemActuator.new(frt_entry_avail_coil_sch, 'Schedule:Year', 'Schedule Value')
|
76
79
|
frt_entry_coil.setName('FrontEntry_Coil')
|
@@ -114,45 +117,50 @@ module RetailStandalone
|
|
114
117
|
'ASHRAE 169-2013-6B',
|
115
118
|
'ASHRAE 169-2013-7A',
|
116
119
|
'ASHRAE 169-2013-8A'
|
117
|
-
|
118
|
-
|
119
|
-
|
120
|
-
|
121
|
-
|
122
|
-
|
123
|
-
|
124
|
-
|
125
|
-
|
126
|
-
|
127
|
-
|
128
|
-
|
129
|
-
|
130
|
-
|
131
|
-
|
132
|
-
|
133
|
-
|
134
|
-
|
135
|
-
|
136
|
-
|
137
|
-
|
138
|
-
|
139
|
-
|
140
|
-
|
141
|
-
|
142
|
-
|
143
|
-
|
120
|
+
[
|
121
|
+
{ '90.1-2010' => { 'Core_Retail' => { 'sensor_1_frac' => 0.1724,
|
122
|
+
'sensor_1_xyz' => [9.144, 24.698, 0] } },
|
123
|
+
'90.1-2013' => { 'Core_Retail' => { 'sensor_1_frac' => 0.1724,
|
124
|
+
'sensor_1_xyz' => [9.144, 24.698, 0] } },
|
125
|
+
'90.1-2016' => { 'Core_Retail' => { 'sensor_1_frac' => 0.1724,
|
126
|
+
'sensor_1_xyz' => [9.144, 24.698, 0] } },
|
127
|
+
'90.1-2019' => { 'Core_Retail' => { 'sensor_1_frac' => 0.1724,
|
128
|
+
'sensor_1_xyz' => [9.144, 24.698, 0] } } }
|
129
|
+
]
|
130
|
+
else
|
131
|
+
[
|
132
|
+
{ '90.1-2010' => { 'Core_Retail' => { 'sensor_1_frac' => 0.25,
|
133
|
+
'sensor_2_frac' => 0.25,
|
134
|
+
'sensor_1_xyz' => [14.2, 14.2, 0],
|
135
|
+
'sensor_2_xyz' => [3.4, 14.2, 0] } },
|
136
|
+
'90.1-2013' => { 'Core_Retail' => { 'sensor_1_frac' => 0.25,
|
137
|
+
'sensor_2_frac' => 0.25,
|
138
|
+
'sensor_1_xyz' => [14.2, 14.2, 0],
|
139
|
+
'sensor_2_xyz' => [3.4, 14.2, 0] } },
|
140
|
+
'90.1-2016' => { 'Core_Retail' => { 'sensor_1_frac' => 0.25,
|
141
|
+
'sensor_2_frac' => 0.25,
|
142
|
+
'sensor_1_xyz' => [14.2, 14.2, 0],
|
143
|
+
'sensor_2_xyz' => [3.4, 14.2, 0] } },
|
144
|
+
'90.1-2019' => { 'Core_Retail' => { 'sensor_1_frac' => 0.25,
|
145
|
+
'sensor_2_frac' => 0.25,
|
146
|
+
'sensor_1_xyz' => [14.2, 14.2, 0],
|
147
|
+
'sensor_2_xyz' => [3.4, 14.2, 0] } } }
|
148
|
+
]
|
144
149
|
end
|
145
150
|
|
146
151
|
# Adjust daylight sensors in each space
|
147
152
|
model.getSpaces.each do |space|
|
148
|
-
if adjustments[0].keys.include?
|
149
|
-
if adjustments[0][template].keys.include?
|
153
|
+
if adjustments[0].keys.include? template
|
154
|
+
if adjustments[0][template].keys.include? space.name.to_s
|
150
155
|
adj = adjustments[0][template][space.name.to_s]
|
151
156
|
next if space.thermalZone.empty?
|
157
|
+
|
152
158
|
zone = space.thermalZone.get
|
153
159
|
next if space.spaceType.empty?
|
160
|
+
|
154
161
|
spc_type = space.spaceType.get
|
155
162
|
next if spc_type.standardsSpaceType.empty?
|
163
|
+
|
156
164
|
stds_spc_type = spc_type.standardsSpaceType.get
|
157
165
|
# Adjust the primary sensor
|
158
166
|
if adj['sensor_1_frac'] && zone.primaryDaylightingControl.is_initialized
|
@@ -195,14 +203,16 @@ module RetailStandalone
|
|
195
203
|
end
|
196
204
|
|
197
205
|
def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
|
198
|
-
|
199
206
|
return true
|
200
207
|
end
|
201
208
|
|
202
209
|
def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
|
210
|
+
# Set original building North axis
|
211
|
+
model_set_building_north_axis(model, 0.0)
|
212
|
+
|
203
213
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Adjusting geometry input')
|
204
214
|
case template
|
205
|
-
when '90.1-2010', '90.1-2013'
|
215
|
+
when '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
206
216
|
case climate_zone
|
207
217
|
when 'ASHRAE 169-2006-6A',
|
208
218
|
'ASHRAE 169-2006-6B',
|
@@ -1,4 +1,3 @@
|
|
1
|
-
|
2
1
|
# Custom changes for the RetailStripmall prototype.
|
3
2
|
# These are changes that are inconsistent with other prototype
|
4
3
|
# building types.
|
@@ -15,13 +14,17 @@ module RetailStripmall
|
|
15
14
|
door_infiltration_map = { ['LGstore1', 'LGstore2'] => 0.388884328,
|
16
15
|
['SMstore1', 'SMstore2', 'SMstore3', 'SMstore4', 'SMstore5', 'SMstore6', 'SMstore7', 'SMstore8'] => 0.222287037 }
|
17
16
|
infiltration_schedule = model_add_schedule(model, 'RetailStripmall INFIL_Door_Opening_SCH')
|
18
|
-
when '90.1-2007', '90.1-2010', '90.1-2013'
|
17
|
+
when '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
19
18
|
case climate_zone
|
20
|
-
when 'ASHRAE 169-2006-
|
19
|
+
when 'ASHRAE 169-2006-0A',
|
20
|
+
'ASHRAE 169-2006-1A',
|
21
|
+
'ASHRAE 169-2006-0B',
|
21
22
|
'ASHRAE 169-2006-1B',
|
22
23
|
'ASHRAE 169-2006-2A',
|
23
24
|
'ASHRAE 169-2006-2B',
|
25
|
+
'ASHRAE 169-2013-0A',
|
24
26
|
'ASHRAE 169-2013-1A',
|
27
|
+
'ASHRAE 169-2013-0B',
|
25
28
|
'ASHRAE 169-2013-1B',
|
26
29
|
'ASHRAE 169-2013-2A',
|
27
30
|
'ASHRAE 169-2013-2B'
|
@@ -60,7 +63,7 @@ module RetailStripmall
|
|
60
63
|
|
61
64
|
# Add economizer max fraction schedules
|
62
65
|
case template
|
63
|
-
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', 'NREL ZNE Ready 2017'
|
66
|
+
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019', 'NREL ZNE Ready 2017'
|
64
67
|
econ_eff_sch = model_add_schedule(model, 'RetailStandalone PSZ_Econ_MaxOAFrac_Sch')
|
65
68
|
model.getAirLoopHVACs.each do |air_loop|
|
66
69
|
oa_sys = air_loop.airLoopHVACOutdoorAirSystem
|
@@ -79,11 +82,12 @@ module RetailStripmall
|
|
79
82
|
# add hvac
|
80
83
|
|
81
84
|
def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
|
82
|
-
|
83
85
|
return true
|
84
86
|
end
|
85
87
|
|
86
88
|
def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
|
89
|
+
# Set original building North axis
|
90
|
+
model_set_building_north_axis(model, 0.0)
|
87
91
|
|
88
92
|
return true
|
89
93
|
end
|
@@ -1,27 +1,37 @@
|
|
1
|
-
|
2
1
|
# Custom changes for the SecondarySchool prototype.
|
3
2
|
# These are changes that are inconsistent with other prototype
|
4
3
|
# building types.
|
5
4
|
module SecondarySchool
|
6
5
|
def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model)
|
7
|
-
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments')
|
6
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific HVAC adjustments')
|
8
7
|
|
9
8
|
# add transformer
|
10
|
-
|
9
|
+
# efficiency based on a 225 kVA transformer
|
11
10
|
case template
|
12
11
|
when '90.1-2004', '90.1-2007'
|
13
12
|
transformer_efficiency = 0.974
|
14
13
|
when '90.1-2010', '90.1-2013'
|
15
14
|
transformer_efficiency = 0.985
|
15
|
+
when '90.1-2016', '90.1-2019'
|
16
|
+
transformer_efficiency = 0.989
|
17
|
+
else
|
18
|
+
transformer_efficiency = nil
|
16
19
|
end
|
17
20
|
return true unless !transformer_efficiency.nil?
|
18
21
|
|
22
|
+
# Change to output variable name in E+ 9.4 (OS 3.1.0)
|
23
|
+
excluded_interiorequip_variable = if model.version < OpenStudio::VersionString.new('3.1.0')
|
24
|
+
'Electric Equipment Electric Energy'
|
25
|
+
else
|
26
|
+
'Electric Equipment Electricity Energy'
|
27
|
+
end
|
28
|
+
|
19
29
|
model_add_transformer(model,
|
20
30
|
wired_lighting_frac: 0.0194,
|
21
31
|
transformer_size: 225000,
|
22
32
|
transformer_efficiency: transformer_efficiency,
|
23
33
|
excluded_interiorequip_key: '2 Elevator Lift Motors',
|
24
|
-
excluded_interiorequip_meter:
|
34
|
+
excluded_interiorequip_meter: excluded_interiorequip_variable)
|
25
35
|
|
26
36
|
# add extra equipment for kitchen
|
27
37
|
add_extra_equip_kitchen(model)
|
@@ -66,14 +76,14 @@ module SecondarySchool
|
|
66
76
|
elec_equip_def1.setName('Kitchen Electric Equipment Definition1')
|
67
77
|
elec_equip_def2.setName('Kitchen Electric Equipment Definition2')
|
68
78
|
case template
|
69
|
-
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013'
|
79
|
+
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
70
80
|
elec_equip_def1.setFractionLatent(0)
|
71
81
|
elec_equip_def1.setFractionRadiant(0.25)
|
72
82
|
elec_equip_def1.setFractionLost(0)
|
73
83
|
elec_equip_def2.setFractionLatent(0)
|
74
84
|
elec_equip_def2.setFractionRadiant(0.25)
|
75
85
|
elec_equip_def2.setFractionLost(0)
|
76
|
-
if template == '90.1-2013'
|
86
|
+
if template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019'
|
77
87
|
elec_equip_def1.setDesignLevel(915)
|
78
88
|
elec_equip_def2.setDesignLevel(570)
|
79
89
|
else
|
@@ -96,7 +106,7 @@ module SecondarySchool
|
|
96
106
|
model.getWaterHeaterMixeds.sort.each do |water_heater|
|
97
107
|
if water_heater.name.to_s.include?('Booster')
|
98
108
|
water_heater.resetAmbientTemperatureSchedule
|
99
|
-
water_heater.setAmbientTemperatureIndicator('ThermalZone')
|
109
|
+
water_heater.setAmbientTemperatureIndicator('ThermalZone')
|
100
110
|
water_heater.setAmbientTemperatureThermalZone(model.getThermalZoneByName('Kitchen_ZN_1_FLR_1 ZN').get)
|
101
111
|
end
|
102
112
|
end
|
@@ -112,351 +122,549 @@ module SecondarySchool
|
|
112
122
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Adjusting daylight sensor positions and fractions')
|
113
123
|
|
114
124
|
adjustments = [
|
115
|
-
|
116
|
-
|
117
|
-
|
118
|
-
|
119
|
-
|
120
|
-
|
121
|
-
|
122
|
-
|
123
|
-
|
124
|
-
|
125
|
-
|
126
|
-
|
127
|
-
|
128
|
-
|
129
|
-
|
130
|
-
|
131
|
-
|
132
|
-
|
133
|
-
|
134
|
-
|
135
|
-
|
136
|
-
|
137
|
-
|
138
|
-
|
139
|
-
|
140
|
-
|
141
|
-
|
142
|
-
|
143
|
-
|
144
|
-
|
145
|
-
|
146
|
-
|
147
|
-
|
148
|
-
|
149
|
-
|
150
|
-
|
151
|
-
|
152
|
-
|
153
|
-
|
154
|
-
|
155
|
-
|
156
|
-
|
157
|
-
|
158
|
-
|
159
|
-
|
160
|
-
|
161
|
-
|
162
|
-
|
163
|
-
|
164
|
-
|
165
|
-
|
166
|
-
|
167
|
-
|
168
|
-
|
169
|
-
|
170
|
-
|
171
|
-
|
172
|
-
|
173
|
-
|
174
|
-
|
175
|
-
|
176
|
-
|
177
|
-
|
178
|
-
|
179
|
-
|
180
|
-
|
181
|
-
|
182
|
-
|
183
|
-
|
184
|
-
|
185
|
-
|
186
|
-
|
187
|
-
|
188
|
-
|
189
|
-
|
190
|
-
|
191
|
-
|
192
|
-
|
193
|
-
|
194
|
-
|
195
|
-
|
196
|
-
|
197
|
-
|
198
|
-
|
199
|
-
|
200
|
-
|
201
|
-
|
202
|
-
|
203
|
-
|
204
|
-
|
205
|
-
|
206
|
-
|
207
|
-
|
208
|
-
|
209
|
-
|
210
|
-
|
211
|
-
|
212
|
-
|
213
|
-
|
214
|
-
|
215
|
-
|
216
|
-
|
217
|
-
|
218
|
-
|
219
|
-
|
220
|
-
|
221
|
-
|
222
|
-
|
223
|
-
|
224
|
-
|
225
|
-
|
226
|
-
|
227
|
-
|
228
|
-
|
229
|
-
|
230
|
-
|
231
|
-
|
232
|
-
|
233
|
-
|
234
|
-
|
235
|
-
|
236
|
-
|
237
|
-
|
238
|
-
|
239
|
-
|
240
|
-
|
241
|
-
|
242
|
-
|
243
|
-
|
244
|
-
|
245
|
-
|
246
|
-
|
247
|
-
|
248
|
-
|
249
|
-
|
250
|
-
|
251
|
-
|
252
|
-
|
253
|
-
|
254
|
-
|
255
|
-
|
256
|
-
|
257
|
-
|
258
|
-
|
259
|
-
|
260
|
-
|
261
|
-
|
262
|
-
|
263
|
-
|
264
|
-
|
265
|
-
|
266
|
-
|
267
|
-
|
268
|
-
|
269
|
-
|
270
|
-
|
271
|
-
|
272
|
-
|
273
|
-
|
274
|
-
|
275
|
-
|
276
|
-
|
277
|
-
|
278
|
-
|
279
|
-
|
280
|
-
|
281
|
-
|
282
|
-
|
283
|
-
|
284
|
-
|
285
|
-
|
286
|
-
|
287
|
-
|
288
|
-
|
289
|
-
|
290
|
-
|
291
|
-
|
292
|
-
|
293
|
-
|
294
|
-
|
295
|
-
|
296
|
-
|
297
|
-
|
298
|
-
|
299
|
-
|
300
|
-
|
301
|
-
|
302
|
-
|
303
|
-
|
304
|
-
|
305
|
-
|
306
|
-
|
307
|
-
|
308
|
-
|
309
|
-
|
310
|
-
|
311
|
-
|
312
|
-
|
313
|
-
|
314
|
-
|
315
|
-
|
316
|
-
|
317
|
-
|
318
|
-
|
319
|
-
|
320
|
-
|
321
|
-
|
322
|
-
|
323
|
-
|
324
|
-
|
325
|
-
|
326
|
-
|
327
|
-
|
328
|
-
|
329
|
-
|
330
|
-
|
331
|
-
|
332
|
-
|
333
|
-
|
334
|
-
|
335
|
-
|
336
|
-
|
337
|
-
|
338
|
-
|
339
|
-
|
340
|
-
|
341
|
-
|
342
|
-
|
343
|
-
|
344
|
-
|
345
|
-
|
346
|
-
|
347
|
-
|
348
|
-
|
349
|
-
|
350
|
-
|
351
|
-
|
352
|
-
|
353
|
-
|
354
|
-
|
355
|
-
|
356
|
-
|
357
|
-
|
358
|
-
|
359
|
-
|
360
|
-
|
361
|
-
|
362
|
-
|
363
|
-
|
364
|
-
|
365
|
-
|
366
|
-
|
367
|
-
|
368
|
-
|
369
|
-
|
370
|
-
|
371
|
-
|
372
|
-
|
373
|
-
|
374
|
-
|
375
|
-
|
376
|
-
|
377
|
-
|
378
|
-
|
379
|
-
|
380
|
-
|
381
|
-
|
382
|
-
|
383
|
-
|
384
|
-
|
385
|
-
|
386
|
-
|
387
|
-
|
388
|
-
|
389
|
-
|
390
|
-
|
391
|
-
|
392
|
-
|
393
|
-
|
394
|
-
|
395
|
-
|
396
|
-
|
397
|
-
|
398
|
-
|
399
|
-
|
400
|
-
|
401
|
-
|
402
|
-
|
403
|
-
|
404
|
-
|
405
|
-
|
406
|
-
|
407
|
-
|
408
|
-
|
409
|
-
|
410
|
-
|
411
|
-
|
412
|
-
|
413
|
-
|
414
|
-
|
415
|
-
|
416
|
-
|
417
|
-
|
418
|
-
|
419
|
-
|
420
|
-
|
421
|
-
|
422
|
-
|
423
|
-
|
424
|
-
|
425
|
-
|
426
|
-
|
427
|
-
|
428
|
-
|
429
|
-
|
430
|
-
|
431
|
-
|
432
|
-
|
433
|
-
|
434
|
-
|
435
|
-
|
436
|
-
|
437
|
-
|
438
|
-
|
439
|
-
|
440
|
-
|
441
|
-
|
442
|
-
|
443
|
-
|
444
|
-
|
445
|
-
|
446
|
-
|
447
|
-
|
448
|
-
|
125
|
+
{ '90.1-2010' => { 'Auditorium_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.125,
|
126
|
+
'sensor_2_frac' => 0.125,
|
127
|
+
'sensor_1_xyz' => [9.5006, 21.7328, 0.762],
|
128
|
+
'sensor_2_xyz' => [28.5004, 21.7328, 0.762] },
|
129
|
+
'Aux_Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
130
|
+
'sensor_2_frac' => 0.5,
|
131
|
+
'sensor_1_xyz' => [12, 24, 0],
|
132
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
133
|
+
'Cafeteria_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.095,
|
134
|
+
'sensor_2_frac' => 0.095,
|
135
|
+
'sensor_1_xyz' => [22.3236, 13, 0.762],
|
136
|
+
'sensor_2_xyz' => [12, 24.3236, 0.762] },
|
137
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.22,
|
138
|
+
'sensor_2_frac' => 0.22,
|
139
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
140
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
141
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.22,
|
142
|
+
'sensor_2_frac' => 0.22,
|
143
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
144
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
145
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.22,
|
146
|
+
'sensor_2_frac' => 0.22,
|
147
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
148
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
149
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.22,
|
150
|
+
'sensor_2_frac' => 0.22,
|
151
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
152
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
153
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.22,
|
154
|
+
'sensor_2_frac' => 0.22,
|
155
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
156
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
157
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.22,
|
158
|
+
'sensor_2_frac' => 0.22,
|
159
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
160
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
161
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.22,
|
162
|
+
'sensor_2_frac' => 0.22,
|
163
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
164
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
165
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.22,
|
166
|
+
'sensor_2_frac' => 0.22,
|
167
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
168
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
169
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.22,
|
170
|
+
'sensor_2_frac' => 0.22,
|
171
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
172
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
173
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.22,
|
174
|
+
'sensor_2_frac' => 0.22,
|
175
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
176
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
177
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.22,
|
178
|
+
'sensor_2_frac' => 0.22,
|
179
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
180
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
181
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.22,
|
182
|
+
'sensor_2_frac' => 0.22,
|
183
|
+
'sensor_1_xyz' => [1.6764, 4.5, 0.762],
|
184
|
+
'sensor_2_xyz' => [5.5, 1.6764, 0.762] },
|
185
|
+
'Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
186
|
+
'sensor_2_frac' => 0.5,
|
187
|
+
'sensor_1_xyz' => [19, 24, 0],
|
188
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
189
|
+
'LIBRARY_MEDIA_CENTER_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.085,
|
190
|
+
'sensor_2_frac' => 0.085,
|
191
|
+
'sensor_1_xyz' => [22.3236, 17.5, 0.762],
|
192
|
+
'sensor_2_xyz' => [12, 33.3236, 0.762] },
|
193
|
+
'Lobby_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.09,
|
194
|
+
'sensor_2_frac' => 0.09,
|
195
|
+
'sensor_1_xyz' => [3.7338, 1.6764, 0.762],
|
196
|
+
'sensor_2_xyz' => [11.2014, 1.6764, 0.762] },
|
197
|
+
'Lobby_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.09,
|
198
|
+
'sensor_2_frac' => 0.09,
|
199
|
+
'sensor_1_xyz' => [3.7338, 1.6764, 0.762],
|
200
|
+
'sensor_2_xyz' => [11.2014, 1.6764, 0.762] },
|
201
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.14,
|
202
|
+
'sensor_2_frac' => 0.14,
|
203
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
204
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
205
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.14,
|
206
|
+
'sensor_2_frac' => 0.14,
|
207
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
208
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
209
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.14,
|
210
|
+
'sensor_2_frac' => 0.14,
|
211
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
212
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
213
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.14,
|
214
|
+
'sensor_2_frac' => 0.14,
|
215
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
216
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
217
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.14,
|
218
|
+
'sensor_2_frac' => 0.14,
|
219
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
220
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
221
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.14,
|
222
|
+
'sensor_2_frac' => 0.14,
|
223
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
224
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
225
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.14,
|
226
|
+
'sensor_2_frac' => 0.14,
|
227
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
228
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
229
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.14,
|
230
|
+
'sensor_2_frac' => 0.14,
|
231
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
232
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
233
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.14,
|
234
|
+
'sensor_2_frac' => 0.14,
|
235
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
236
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
237
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.14,
|
238
|
+
'sensor_2_frac' => 0.14,
|
239
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
240
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
241
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.14,
|
242
|
+
'sensor_2_frac' => 0.14,
|
243
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
244
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
245
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.14,
|
246
|
+
'sensor_2_frac' => 0.14,
|
247
|
+
'sensor_1_xyz' => [13.2588, 1.6764, 0.762],
|
248
|
+
'sensor_2_xyz' => [39.7764, 1.6764, 0.762] },
|
249
|
+
'Offices_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.115,
|
250
|
+
'sensor_2_frac' => 0.115,
|
251
|
+
'sensor_1_xyz' => [18.9982, 1.6764, 0.762],
|
252
|
+
'sensor_2_xyz' => [36.3322, 7.0104, 0.762] },
|
253
|
+
'Offices_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.115,
|
254
|
+
'sensor_2_frac' => 0.115,
|
255
|
+
'sensor_1_xyz' => [18.9982, 1.6764, 0.762],
|
256
|
+
'sensor_2_xyz' => [36.3322, 7.0104, 0.762] } },
|
257
|
+
'90.1-2013' => { 'Auditorium_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.125,
|
258
|
+
'sensor_2_frac' => 0.125,
|
259
|
+
'sensor_1_xyz' => [9.5006, 21.7328, 0.762],
|
260
|
+
'sensor_2_xyz' => [28.5004, 21.7328, 0.762] },
|
261
|
+
'Aux_Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
262
|
+
'sensor_2_frac' => 0.5,
|
263
|
+
'sensor_1_xyz' => [12, 24, 0],
|
264
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
265
|
+
'Cafeteria_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.21,
|
266
|
+
'sensor_2_frac' => 0.15,
|
267
|
+
'sensor_1_xyz' => [20.6472, 13, 0.762],
|
268
|
+
'sensor_2_xyz' => [12, 22.6472, 0.762] },
|
269
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
270
|
+
'sensor_2_frac' => 0.2,
|
271
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
272
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
273
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
274
|
+
'sensor_2_frac' => 0.2,
|
275
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
276
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
277
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
278
|
+
'sensor_2_frac' => 0.2,
|
279
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
280
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
281
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
282
|
+
'sensor_2_frac' => 0.2,
|
283
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
284
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
285
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
286
|
+
'sensor_2_frac' => 0.2,
|
287
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
288
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
289
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
290
|
+
'sensor_2_frac' => 0.2,
|
291
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
292
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
293
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
294
|
+
'sensor_2_frac' => 0.2,
|
295
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
296
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
297
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
298
|
+
'sensor_2_frac' => 0.2,
|
299
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
300
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
301
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
302
|
+
'sensor_2_frac' => 0.2,
|
303
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
304
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
305
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
306
|
+
'sensor_2_frac' => 0.2,
|
307
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
308
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
309
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
310
|
+
'sensor_2_frac' => 0.2,
|
311
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
312
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
313
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
314
|
+
'sensor_2_frac' => 0.2,
|
315
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
316
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
317
|
+
'Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
318
|
+
'sensor_2_frac' => 0.5,
|
319
|
+
'sensor_1_xyz' => [19, 24, 0],
|
320
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
321
|
+
'LIBRARY_MEDIA_CENTER_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.21,
|
322
|
+
'sensor_2_frac' => 0.11,
|
323
|
+
'sensor_1_xyz' => [20.6472, 17.5, 0.762],
|
324
|
+
'sensor_2_xyz' => [12, 31.6472, 0.762] },
|
325
|
+
'Lobby_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.18,
|
326
|
+
'sensor_2_frac' => 0.18,
|
327
|
+
'sensor_1_xyz' => [7.5, 1.6764, 0.762],
|
328
|
+
'sensor_2_xyz' => [7.5, 3.3528, 0.762] },
|
329
|
+
'Lobby_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.18,
|
330
|
+
'sensor_2_frac' => 0.18,
|
331
|
+
'sensor_1_xyz' => [7.5, 1.6764, 0.762],
|
332
|
+
'sensor_2_xyz' => [7.5, 3.3528, 0.762] },
|
333
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
334
|
+
'sensor_2_frac' => 0.28,
|
335
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
336
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
337
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
338
|
+
'sensor_2_frac' => 0.28,
|
339
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
340
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
341
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
342
|
+
'sensor_2_frac' => 0.28,
|
343
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
344
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
345
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
346
|
+
'sensor_2_frac' => 0.28,
|
347
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
348
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
349
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
350
|
+
'sensor_2_frac' => 0.28,
|
351
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
352
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
353
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
354
|
+
'sensor_2_frac' => 0.28,
|
355
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
356
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
357
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
358
|
+
'sensor_2_frac' => 0.28,
|
359
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
360
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
361
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
362
|
+
'sensor_2_frac' => 0.28,
|
363
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
364
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
365
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
366
|
+
'sensor_2_frac' => 0.28,
|
367
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
368
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
369
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
370
|
+
'sensor_2_frac' => 0.28,
|
371
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
372
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
373
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
374
|
+
'sensor_2_frac' => 0.28,
|
375
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
376
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
377
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
378
|
+
'sensor_2_frac' => 0.28,
|
379
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
380
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
381
|
+
'Offices_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.36,
|
382
|
+
'sensor_2_frac' => 0.08,
|
383
|
+
'sensor_1_xyz' => [34.6472, 7.0104, 0.762],
|
384
|
+
'sensor_2_xyz' => [18.9982, 3.3528, 0.762] },
|
385
|
+
'Offices_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.36,
|
386
|
+
'sensor_2_frac' => 0.08,
|
387
|
+
'sensor_1_xyz' => [34.6472, 7.0104, 0.762],
|
388
|
+
'sensor_2_xyz' => [18.9982, 3.3528, 0.762] } },
|
389
|
+
'90.1-2016' => { 'Auditorium_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.125,
|
390
|
+
'sensor_2_frac' => 0.125,
|
391
|
+
'sensor_1_xyz' => [9.5006, 21.7328, 0.762],
|
392
|
+
'sensor_2_xyz' => [28.5004, 21.7328, 0.762] },
|
393
|
+
'Aux_Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
394
|
+
'sensor_2_frac' => 0.5,
|
395
|
+
'sensor_1_xyz' => [12, 24, 0],
|
396
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
397
|
+
'Cafeteria_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.21,
|
398
|
+
'sensor_2_frac' => 0.15,
|
399
|
+
'sensor_1_xyz' => [20.6472, 13, 0.762],
|
400
|
+
'sensor_2_xyz' => [12, 22.6472, 0.762] },
|
401
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
402
|
+
'sensor_2_frac' => 0.2,
|
403
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
404
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
405
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
406
|
+
'sensor_2_frac' => 0.2,
|
407
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
408
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
409
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
410
|
+
'sensor_2_frac' => 0.2,
|
411
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
412
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
413
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
414
|
+
'sensor_2_frac' => 0.2,
|
415
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
416
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
417
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
418
|
+
'sensor_2_frac' => 0.2,
|
419
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
420
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
421
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
422
|
+
'sensor_2_frac' => 0.2,
|
423
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
424
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
425
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
426
|
+
'sensor_2_frac' => 0.2,
|
427
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
428
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
429
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
430
|
+
'sensor_2_frac' => 0.2,
|
431
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
432
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
433
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
434
|
+
'sensor_2_frac' => 0.2,
|
435
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
436
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
437
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
438
|
+
'sensor_2_frac' => 0.2,
|
439
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
440
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
441
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
442
|
+
'sensor_2_frac' => 0.2,
|
443
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
444
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
445
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
446
|
+
'sensor_2_frac' => 0.2,
|
447
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
448
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
449
|
+
'Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
450
|
+
'sensor_2_frac' => 0.5,
|
451
|
+
'sensor_1_xyz' => [19, 24, 0],
|
452
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
453
|
+
'LIBRARY_MEDIA_CENTER_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.21,
|
454
|
+
'sensor_2_frac' => 0.11,
|
455
|
+
'sensor_1_xyz' => [20.6472, 17.5, 0.762],
|
456
|
+
'sensor_2_xyz' => [12, 31.6472, 0.762] },
|
457
|
+
'Lobby_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.18,
|
458
|
+
'sensor_2_frac' => 0.18,
|
459
|
+
'sensor_1_xyz' => [7.5, 1.6764, 0.762],
|
460
|
+
'sensor_2_xyz' => [7.5, 3.3528, 0.762] },
|
461
|
+
'Lobby_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.18,
|
462
|
+
'sensor_2_frac' => 0.18,
|
463
|
+
'sensor_1_xyz' => [7.5, 1.6764, 0.762],
|
464
|
+
'sensor_2_xyz' => [7.5, 3.3528, 0.762] },
|
465
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
466
|
+
'sensor_2_frac' => 0.28,
|
467
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
468
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
469
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
470
|
+
'sensor_2_frac' => 0.28,
|
471
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
472
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
473
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
474
|
+
'sensor_2_frac' => 0.28,
|
475
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
476
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
477
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
478
|
+
'sensor_2_frac' => 0.28,
|
479
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
480
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
481
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
482
|
+
'sensor_2_frac' => 0.28,
|
483
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
484
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
485
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
486
|
+
'sensor_2_frac' => 0.28,
|
487
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
488
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
489
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
490
|
+
'sensor_2_frac' => 0.28,
|
491
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
492
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
493
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
494
|
+
'sensor_2_frac' => 0.28,
|
495
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
496
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
497
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
498
|
+
'sensor_2_frac' => 0.28,
|
499
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
500
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
501
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
502
|
+
'sensor_2_frac' => 0.28,
|
503
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
504
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
505
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
506
|
+
'sensor_2_frac' => 0.28,
|
507
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
508
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
509
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
510
|
+
'sensor_2_frac' => 0.28,
|
511
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
512
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
513
|
+
'Offices_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.36,
|
514
|
+
'sensor_2_frac' => 0.08,
|
515
|
+
'sensor_1_xyz' => [34.6472, 7.0104, 0.762],
|
516
|
+
'sensor_2_xyz' => [18.9982, 3.3528, 0.762] },
|
517
|
+
'Offices_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.36,
|
518
|
+
'sensor_2_frac' => 0.08,
|
519
|
+
'sensor_1_xyz' => [34.6472, 7.0104, 0.762],
|
520
|
+
'sensor_2_xyz' => [18.9982, 3.3528, 0.762] } },
|
521
|
+
'90.1-2019' => { 'Auditorium_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.125,
|
522
|
+
'sensor_2_frac' => 0.125,
|
523
|
+
'sensor_1_xyz' => [9.5006, 21.7328, 0.762],
|
524
|
+
'sensor_2_xyz' => [28.5004, 21.7328, 0.762] },
|
525
|
+
'Aux_Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
526
|
+
'sensor_2_frac' => 0.5,
|
527
|
+
'sensor_1_xyz' => [12, 24, 0],
|
528
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
529
|
+
'Cafeteria_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.21,
|
530
|
+
'sensor_2_frac' => 0.15,
|
531
|
+
'sensor_1_xyz' => [20.6472, 13, 0.762],
|
532
|
+
'sensor_2_xyz' => [12, 22.6472, 0.762] },
|
533
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
534
|
+
'sensor_2_frac' => 0.2,
|
535
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
536
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
537
|
+
'Corner_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
538
|
+
'sensor_2_frac' => 0.2,
|
539
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
540
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
541
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
542
|
+
'sensor_2_frac' => 0.2,
|
543
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
544
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
545
|
+
'Corner_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
546
|
+
'sensor_2_frac' => 0.2,
|
547
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
548
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
549
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
550
|
+
'sensor_2_frac' => 0.2,
|
551
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
552
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
553
|
+
'Corner_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
554
|
+
'sensor_2_frac' => 0.2,
|
555
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
556
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
557
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
558
|
+
'sensor_2_frac' => 0.2,
|
559
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
560
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
561
|
+
'Corner_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
562
|
+
'sensor_2_frac' => 0.2,
|
563
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
564
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
565
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
566
|
+
'sensor_2_frac' => 0.2,
|
567
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
568
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
569
|
+
'Corner_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
570
|
+
'sensor_2_frac' => 0.2,
|
571
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
572
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
573
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.56,
|
574
|
+
'sensor_2_frac' => 0.2,
|
575
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
576
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
577
|
+
'Corner_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.56,
|
578
|
+
'sensor_2_frac' => 0.2,
|
579
|
+
'sensor_1_xyz' => [7.6198, 3.3711, 0.762],
|
580
|
+
'sensor_2_xyz' => [3.3711, 6.0313, 0.762] },
|
581
|
+
'Gym_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.5,
|
582
|
+
'sensor_2_frac' => 0.5,
|
583
|
+
'sensor_1_xyz' => [19, 24, 0],
|
584
|
+
'sensor_2_xyz' => [2, 24, 0] },
|
585
|
+
'LIBRARY_MEDIA_CENTER_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.21,
|
586
|
+
'sensor_2_frac' => 0.11,
|
587
|
+
'sensor_1_xyz' => [20.6472, 17.5, 0.762],
|
588
|
+
'sensor_2_xyz' => [12, 31.6472, 0.762] },
|
589
|
+
'Lobby_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.18,
|
590
|
+
'sensor_2_frac' => 0.18,
|
591
|
+
'sensor_1_xyz' => [7.5, 1.6764, 0.762],
|
592
|
+
'sensor_2_xyz' => [7.5, 3.3528, 0.762] },
|
593
|
+
'Lobby_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.18,
|
594
|
+
'sensor_2_frac' => 0.18,
|
595
|
+
'sensor_1_xyz' => [7.5, 1.6764, 0.762],
|
596
|
+
'sensor_2_xyz' => [7.5, 3.3528, 0.762] },
|
597
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
598
|
+
'sensor_2_frac' => 0.28,
|
599
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
600
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
601
|
+
'Mult_Class_1_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
602
|
+
'sensor_2_frac' => 0.28,
|
603
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
604
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
605
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
606
|
+
'sensor_2_frac' => 0.28,
|
607
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
608
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
609
|
+
'Mult_Class_2_Pod_1_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
610
|
+
'sensor_2_frac' => 0.28,
|
611
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
612
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
613
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
614
|
+
'sensor_2_frac' => 0.28,
|
615
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
616
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
617
|
+
'Mult_Class_1_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
618
|
+
'sensor_2_frac' => 0.28,
|
619
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
620
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
621
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
622
|
+
'sensor_2_frac' => 0.28,
|
623
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
624
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
625
|
+
'Mult_Class_2_Pod_2_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
626
|
+
'sensor_2_frac' => 0.28,
|
627
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
628
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
629
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
630
|
+
'sensor_2_frac' => 0.28,
|
631
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
632
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
633
|
+
'Mult_Class_1_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
634
|
+
'sensor_2_frac' => 0.28,
|
635
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
636
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
637
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.28,
|
638
|
+
'sensor_2_frac' => 0.28,
|
639
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
640
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
641
|
+
'Mult_Class_2_Pod_3_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.28,
|
642
|
+
'sensor_2_frac' => 0.28,
|
643
|
+
'sensor_1_xyz' => [26.5, 1.6764, 0.762],
|
644
|
+
'sensor_2_xyz' => [26.5, 3.3528, 0.762] },
|
645
|
+
'Offices_ZN_1_FLR_1 ZN' => { 'sensor_1_frac' => 0.36,
|
646
|
+
'sensor_2_frac' => 0.08,
|
647
|
+
'sensor_1_xyz' => [34.6472, 7.0104, 0.762],
|
648
|
+
'sensor_2_xyz' => [18.9982, 3.3528, 0.762] },
|
649
|
+
'Offices_ZN_1_FLR_2 ZN' => { 'sensor_1_frac' => 0.36,
|
650
|
+
'sensor_2_frac' => 0.08,
|
651
|
+
'sensor_1_xyz' => [34.6472, 7.0104, 0.762],
|
652
|
+
'sensor_2_xyz' => [18.9982, 3.3528, 0.762] } } }
|
653
|
+
]
|
449
654
|
|
450
655
|
# Adjust daylight sensors in each space
|
451
656
|
model.getSpaces.each do |space|
|
452
|
-
if adjustments[0].keys.include?
|
453
|
-
if adjustments[0][template].keys.include?
|
454
|
-
adj = adjustments[0][template][space.name.to_s +
|
657
|
+
if adjustments[0].keys.include?(template)
|
658
|
+
if adjustments[0][template].keys.include?(space.name.to_s + ' ZN')
|
659
|
+
adj = adjustments[0][template][space.name.to_s + ' ZN']
|
455
660
|
next if space.thermalZone.empty?
|
661
|
+
|
456
662
|
zone = space.thermalZone.get
|
457
663
|
next if space.spaceType.empty?
|
664
|
+
|
458
665
|
spc_type = space.spaceType.get
|
459
666
|
next if spc_type.standardsSpaceType.empty?
|
667
|
+
|
460
668
|
stds_spc_type = spc_type.standardsSpaceType.get
|
461
669
|
# Adjust the primary sensor
|
462
670
|
if adj['sensor_1_frac'] && zone.primaryDaylightingControl.is_initialized
|
@@ -496,16 +704,38 @@ module SecondarySchool
|
|
496
704
|
end
|
497
705
|
|
498
706
|
def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model)
|
707
|
+
# Set original building North axis
|
708
|
+
model_set_building_north_axis(model, 0.0)
|
499
709
|
|
500
710
|
return true
|
501
711
|
end
|
502
712
|
|
503
713
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
504
|
-
min_damper_position = template == '90.1-2010' || template == '90.1-2013' ? 0.2 : 0.3
|
714
|
+
min_damper_position = template == '90.1-2010' || template == '90.1-2013' || template == '90.1-2016' || template == '90.1-2019' ? 0.2 : 0.3
|
505
715
|
|
506
716
|
# Set the minimum flow fraction
|
507
717
|
air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position)
|
508
718
|
|
509
719
|
return true
|
510
720
|
end
|
721
|
+
|
722
|
+
# Type of SAT reset for this building type
|
723
|
+
#
|
724
|
+
# @param air_loop_hvac [OpenStudio::model::AirLoopHVAC] Airloop
|
725
|
+
# @return [String] Returns type of SAT reset
|
726
|
+
def air_loop_hvac_supply_air_temperature_reset_type(air_loop_hvac)
|
727
|
+
return 'oa'
|
728
|
+
end
|
729
|
+
|
730
|
+
# List transfer air target and source zones, and air aflow (cfm)
|
731
|
+
#
|
732
|
+
# code_sections [90.1-2019_6.5.7.1], [90.1-2016_6.5.7.1]
|
733
|
+
# @return [Hash] target zones (key) and source zones (value) and air flow (value)
|
734
|
+
def model_transfer_air_target_and_source_zones(model)
|
735
|
+
model_transfer_air_target_and_source_zones_hash = {
|
736
|
+
'Bathrooms_ZN_1_FLR_1 ZN' => ['Main_Corridor_ZN_1_FLR_1 ZN', 600.0],
|
737
|
+
'Bathrooms_ZN_1_FLR_2 ZN' => ['Main_Corridor_ZN_1_FLR_2 ZN', 600.0]
|
738
|
+
}
|
739
|
+
return model_transfer_air_target_and_source_zones_hash
|
740
|
+
end
|
511
741
|
end
|