openstudio-standards 0.2.12.rc4 → 0.2.13.rc3
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAE90120162019HighriseApartment.json +1042 -0
- data/data/geometry/ASHRAE90120162019Hospital.json +199 -0
- data/data/geometry/ASHRAE90120162019LargeHotel.json +73 -0
- data/data/geometry/ASHRAE90120162019LargeOffice.json +109 -0
- data/data/geometry/ASHRAE90120162019SecondarySchool.json +205 -0
- data/data/geometry/ASHRAECourthouse.json +112 -0
- data/data/geometry/ASHRAECourthouse.osm +26470 -0
- data/data/geometry/ASHRAELargeHotel.osm +11 -1
- data/data/geometry/ASHRAELargeOffice.json +4 -0
- data/data/geometry/ASHRAESmallDataCenter.json +1 -1
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/exclude_list.csv +19 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +25426 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +508 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +21446 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +293 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +564 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +184 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +21380 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +49 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +395 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +550 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +466 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +137 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +238 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +21548 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +554 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +64 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +871 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +12487 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +1600 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +592 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +349 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +1096 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +164 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +10663 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +886 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +194 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +44 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +247 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +3094 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +829 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +562 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +52 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +220 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +156 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +1316 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +22079 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +994 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +68 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +28 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +12 -0
- data/data/standards/manage_OpenStudio_Standards.rb +87 -37
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1-ALL-comstockspace_types.csv +236 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +622 -0
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1space_types.csv +191 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +17 -0
- data/data/standards/test_performance_expected_dd_results.csv +1971 -1171
- data/lib/openstudio-standards.rb +76 -18
- data/lib/openstudio-standards/btap/btap.model.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +14 -11
- data/lib/openstudio-standards/btap/envelope.rb +185 -257
- data/lib/openstudio-standards/btap/fileio.rb +1 -0
- data/lib/openstudio-standards/btap/geometry.rb +21 -1
- data/lib/openstudio-standards/btap/measures.rb +12 -11
- data/lib/openstudio-standards/btap/schedules.rb +3 -12
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.rb +178 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingDXMultiSpeed.rb +8 -8
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +3 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +28 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +53 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +157 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +29 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +366 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +367 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +144 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +74 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +46 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +23 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +26 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +8 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +54 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +56 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +38 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +218 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +6 -2
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +230 -134
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +60 -62
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +25 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +34 -22
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +31 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +43 -28
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +48 -38
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +575 -345
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +13 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +13 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +9 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +79 -51
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +60 -60
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +133 -120
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +124 -112
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +138 -66
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +7275 -199
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +35 -35
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +4 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +7 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +13 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +7 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +0 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +25 -14
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +474 -89
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +35 -33
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +72 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +120 -120
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +142 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +9 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +11 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +26 -14
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +270 -247
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/refs/references.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +70 -51
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -0
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +91 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -5
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +30 -9
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +0 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +37 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -3
- data/lib/openstudio-standards/standards/Standards.Construction.rb +124 -118
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -4
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +10 -3
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +305 -247
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -9
- data/lib/openstudio-standards/standards/Standards.Pump.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +0 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +103 -121
- data/lib/openstudio-standards/standards/Standards.Space.rb +42 -35
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +9 -17
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +25 -27
- data/lib/openstudio-standards/standards/Standards.Surface.rb +97 -52
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +76 -25
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +6 -7
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +85 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +10 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +2420 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +70 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +105 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +5 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +32 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +104 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +32 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +52 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +123 -39
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +112 -25
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +37 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +1460 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +64 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +104 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +125 -41
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +172 -55
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +15 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +532 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +648 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +456 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +189 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +57 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.chillers.json +490 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_properties.json +21244 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.construction_sets.json +2111 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.economizers.json +676 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.elevators.json +372 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +1096 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +664 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +204 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_rejection.json +49 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.prototype_inputs.json +3094 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_cases.json +854 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.ref_lnup.json +562 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +58 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_condenser.json +238 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_system.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_walkins.json +1316 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +23067 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +671 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +1662 -332
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +4994 -234
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +1743 -161
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +5967 -2727
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +63 -99
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.ext_ltg.json +10 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +7 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +5920 -2700
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +2011 -1112
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +0 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +9 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +1946 -1106
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +3 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -3
- data/lib/openstudio-standards/standards/cbes/cbes.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +8 -13
- data/lib/openstudio-standards/standards/deer/deer.Model.rb +2 -2
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +2 -0
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +0 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +0 -1
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +0 -1
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +2 -18
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +87 -15
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +31 -19
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/curves.json +75 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -16
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +1677 -1005
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +16 -2
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +15 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +14 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +913 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/equip_eff_lim.json +52 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/erv.json +109 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +23 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +803 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +787 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/pv.json +112 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +29 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/unitary_acs.json +50 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +100 -0
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +33 -0
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1729 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +189 -0
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +104 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +68 -33
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +24 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +110 -99
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +24 -24
- data/lib/openstudio-standards/standards/necb/NECB2011/data/curves.json +50 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/erv.json +31 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +39278 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/led_lighting_data.json +2028 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1745 -1297
- data/lib/openstudio-standards/standards/necb/NECB2011/daylighting_control.md +70 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/demand_controlled_ventilation.md +46 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +69 -107
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +41 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +15 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +139 -141
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +38 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +12 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +492 -240
- data/lib/openstudio-standards/standards/necb/NECB2011/led_lighting.md +51 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +75 -9
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +1229 -37
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +74 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/pv_ground.md +44 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +11 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_resources/neb_end_use_prices.csv +39 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +32 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +2554 -1916
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +29 -0
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +0 -1
- data/lib/openstudio-standards/standards/standard.rb +6 -5
- data/lib/openstudio-standards/utilities/Add_template_field_to_json.rb +3 -3
- data/lib/openstudio-standards/utilities/convert_surfaces_to_adiabatic_necb_8426.rb +54 -54
- data/lib/openstudio-standards/utilities/generate_prototype_database.rb +2 -2
- data/lib/openstudio-standards/utilities/generate_space_types.rb +3 -3
- data/lib/openstudio-standards/utilities/logging.rb +7 -7
- data/lib/openstudio-standards/utilities/necb_to_epw_map.rb +14 -14
- data/lib/openstudio-standards/utilities/os_sim_extract.rb +25 -25
- data/lib/openstudio-standards/utilities/rename_surfaces.rb +10 -13
- data/lib/openstudio-standards/utilities/round_surf_coords.rb +18 -20
- data/lib/openstudio-standards/utilities/sched_create.rb +39 -41
- data/lib/openstudio-standards/utilities/set_mult_to_adiabatic.rb +31 -31
- data/lib/openstudio-standards/utilities/simulation.rb +13 -21
- data/lib/openstudio-standards/utilities/speacetype_map_converter.rb +10 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +6 -8
- data/lib/openstudio-standards/utilities/template_measure/measure.rb +108 -0
- data/lib/openstudio-standards/utilities/template_measure/measure.xml +162 -0
- data/lib/openstudio-standards/utilities/template_measure/resources/BTAPMeasureHelper.rb +448 -0
- data/lib/openstudio-standards/utilities/template_measure/tests/test.rb +160 -0
- data/lib/openstudio-standards/utilities/weatherData1_xlsx_to_json.rb +23 -26
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +112 -87
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +17 -17
- metadata +236 -2
@@ -0,0 +1,144 @@
|
|
1
|
+
class ASHRAE9012016 < ASHRAE901
|
2
|
+
# @!group Pump
|
3
|
+
|
4
|
+
# Determine type of pump part load control type
|
5
|
+
#
|
6
|
+
# @code_sections [90.1-2016_6.5.4.2]
|
7
|
+
# @param pump [OpenStudio::Model::PumpVariableSpeed] OpenStudio pump object
|
8
|
+
# @param plant_loop_type [String] Type of plant loop
|
9
|
+
# @param pump_nominal_hp [Float] Pump nominal horsepower
|
10
|
+
# @return [String] Pump part load control type
|
11
|
+
def pump_variable_speed_get_control_type(pump, plant_loop_type, pump_nominal_hp)
|
12
|
+
# Sizing factor to take into account that pumps
|
13
|
+
# are typically sized to handle a ~10% pressure
|
14
|
+
# increase and ~10% flow increase.
|
15
|
+
design_sizing_factor = 1.25
|
16
|
+
|
17
|
+
# Get climate zone
|
18
|
+
climate_zone = pump.plantLoop.get.model.getClimateZones.getClimateZone(0)
|
19
|
+
climate_zone = "#{climate_zone.institution} 169-#{climate_zone.year}-#{climate_zone.value}"
|
20
|
+
|
21
|
+
# Get nameplate hp threshold:
|
22
|
+
# The thresholds below represent the nameplate
|
23
|
+
# hp one level lower than the threshold in the
|
24
|
+
# code. Motor size from table in section 10 are
|
25
|
+
# used as reference.
|
26
|
+
case plant_loop_type
|
27
|
+
when 'Heating'
|
28
|
+
case climate_zone
|
29
|
+
when 'ASHRAE 169-2006-7A',
|
30
|
+
'ASHRAE 169-2006-7B',
|
31
|
+
'ASHRAE 169-2006-8A',
|
32
|
+
'ASHRAE 169-2006-8B',
|
33
|
+
'ASHRAE 169-2013-7A',
|
34
|
+
'ASHRAE 169-2013-7B',
|
35
|
+
'ASHRAE 169-2013-8A',
|
36
|
+
'ASHRAE 169-2013-8B'
|
37
|
+
threshold = 3
|
38
|
+
when 'ASHRAE 169-2006-3C',
|
39
|
+
'ASHRAE 169-2006-5A',
|
40
|
+
'ASHRAE 169-2006-5C',
|
41
|
+
'ASHRAE 169-2006-6A',
|
42
|
+
'ASHRAE 169-2006-6B',
|
43
|
+
'ASHRAE 169-2013-3C',
|
44
|
+
'ASHRAE 169-2013-5A',
|
45
|
+
'ASHRAE 169-2013-5C',
|
46
|
+
'ASHRAE 169-2013-6A',
|
47
|
+
'ASHRAE 169-2013-6B'
|
48
|
+
threshold = 5
|
49
|
+
when 'ASHRAE 169-2006-4A',
|
50
|
+
'ASHRAE 169-2006-4C',
|
51
|
+
'ASHRAE 169-2006-5B',
|
52
|
+
'ASHRAE 169-2013-4A',
|
53
|
+
'ASHRAE 169-2013-4C',
|
54
|
+
'ASHRAE 169-2013-5B'
|
55
|
+
threshold = 7.5
|
56
|
+
when 'ASHRAE 169-2006-4B',
|
57
|
+
'ASHRAE 169-2013-4B'
|
58
|
+
threshold = 10
|
59
|
+
when 'ASHRAE 169-2006-2A',
|
60
|
+
'ASHRAE 169-2006-2B',
|
61
|
+
'ASHRAE 169-2006-3A',
|
62
|
+
'ASHRAE 169-2006-3B',
|
63
|
+
'ASHRAE 169-2013-2A',
|
64
|
+
'ASHRAE 169-2013-2B',
|
65
|
+
'ASHRAE 169-2013-3A',
|
66
|
+
'ASHRAE 169-2013-3B'
|
67
|
+
threshold = 20
|
68
|
+
when 'ASHRAE 169-2006-1B',
|
69
|
+
'ASHRAE 169-2013-1B'
|
70
|
+
threshold = 75
|
71
|
+
when 'ASHRAE 169-2006-0A',
|
72
|
+
'ASHRAE 169-2006-0B',
|
73
|
+
'ASHRAE 169-2006-1A',
|
74
|
+
'ASHRAE 169-2013-0A',
|
75
|
+
'ASHRAE 169-2013-0B',
|
76
|
+
'ASHRAE 169-2013-1A'
|
77
|
+
threshold = 150
|
78
|
+
else
|
79
|
+
OpenStudio.logFree(OpenStudio::Warn, "Pump flow control requirement missing for heating water pumps in climate zone: #{climate_zone}.")
|
80
|
+
end
|
81
|
+
when 'Cooling'
|
82
|
+
case climate_zone
|
83
|
+
when 'ASHRAE 169-2006-0A',
|
84
|
+
'ASHRAE 169-2006-0B',
|
85
|
+
'ASHRAE 169-2006-1A',
|
86
|
+
'ASHRAE 169-2006-1B',
|
87
|
+
'ASHRAE 169-2006-2B',
|
88
|
+
'ASHRAE 169-2013-0A',
|
89
|
+
'ASHRAE 169-2013-0B',
|
90
|
+
'ASHRAE 169-2013-1A',
|
91
|
+
'ASHRAE 169-2013-1B',
|
92
|
+
'ASHRAE 169-2013-2B'
|
93
|
+
threshold = 1.5
|
94
|
+
when 'ASHRAE 169-2006-2A',
|
95
|
+
'ASHRAE 169-2006-3B',
|
96
|
+
'ASHRAE 169-2013-2A',
|
97
|
+
'ASHRAE 169-2013-3B'
|
98
|
+
threshold = 2
|
99
|
+
when 'ASHRAE 169-2006-3A',
|
100
|
+
'ASHRAE 169-2006-3C',
|
101
|
+
'ASHRAE 169-2006-4A',
|
102
|
+
'ASHRAE 169-2006-4B',
|
103
|
+
'ASHRAE 169-2013-3A',
|
104
|
+
'ASHRAE 169-2013-3C',
|
105
|
+
'ASHRAE 169-2013-4A',
|
106
|
+
'ASHRAE 169-2013-4B'
|
107
|
+
threshold = 3
|
108
|
+
when 'ASHRAE 169-2006-4C',
|
109
|
+
'ASHRAE 169-2006-5A',
|
110
|
+
'ASHRAE 169-2006-5B',
|
111
|
+
'ASHRAE 169-2006-5C',
|
112
|
+
'ASHRAE 169-2006-6A',
|
113
|
+
'ASHRAE 169-2006-6B',
|
114
|
+
'ASHRAE 169-2013-4C',
|
115
|
+
'ASHRAE 169-2013-5A',
|
116
|
+
'ASHRAE 169-2013-5B',
|
117
|
+
'ASHRAE 169-2013-5C',
|
118
|
+
'ASHRAE 169-2013-6A',
|
119
|
+
'ASHRAE 169-2013-6B'
|
120
|
+
threshold = 5
|
121
|
+
when 'ASHRAE 169-2006-7A',
|
122
|
+
'ASHRAE 169-2006-7B',
|
123
|
+
'ASHRAE 169-2006-8A',
|
124
|
+
'ASHRAE 169-2006-8B',
|
125
|
+
'ASHRAE 169-2013-7A',
|
126
|
+
'ASHRAE 169-2013-7B',
|
127
|
+
'ASHRAE 169-2013-8A',
|
128
|
+
'ASHRAE 169-2013-8B'
|
129
|
+
threshold = 10
|
130
|
+
else
|
131
|
+
OpenStudio.logFree(OpenStudio::Warn, "Pump flow control requirement missing for chilled water pumps in climate zone: #{climate_zone}.")
|
132
|
+
end
|
133
|
+
else
|
134
|
+
OpenStudio.logFree(OpenStudio::Warn, "No pump flow requirement for #{plant_loop_type} plant loops.")
|
135
|
+
return false
|
136
|
+
end
|
137
|
+
|
138
|
+
if pump_nominal_hp * design_sizing_factor > threshold
|
139
|
+
return 'VSD DP Reset'
|
140
|
+
else
|
141
|
+
return 'Riding Curve'
|
142
|
+
end
|
143
|
+
end
|
144
|
+
end
|
@@ -0,0 +1,11 @@
|
|
1
|
+
class ASHRAE9012016 < ASHRAE901
|
2
|
+
# @!group hvac_systems
|
3
|
+
|
4
|
+
# Determine which type of fan the cooling tower
|
5
|
+
# will have. Variable Speed Fan for ASHRAE 90.1-2016.
|
6
|
+
# @return [String] the fan type: TwoSpeed Fan, Variable Speed Fan
|
7
|
+
def model_cw_loop_cooling_tower_fan_type(model)
|
8
|
+
fan_type = 'Variable Speed Fan'
|
9
|
+
return fan_type
|
10
|
+
end
|
11
|
+
end
|
@@ -0,0 +1,24 @@
|
|
1
|
+
class ASHRAE9012019 < ASHRAE901
|
2
|
+
# @!group AirTerminalSingleDuctVAVReheat
|
3
|
+
# Set the initial minimum damper position based on OA rate of the space and the template.
|
4
|
+
# Zones with low OA per area get lower initial guesses.
|
5
|
+
# Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions
|
6
|
+
#
|
7
|
+
# @param zone_oa_per_area [Double] the zone outdoor air per area, m^3/s
|
8
|
+
# @return [Bool] returns true if successful, false if not
|
9
|
+
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
10
|
+
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
11
|
+
when 'HotWater'
|
12
|
+
0.2
|
13
|
+
when 'Electricity', 'NaturalGas'
|
14
|
+
0.3
|
15
|
+
else
|
16
|
+
0.2
|
17
|
+
end
|
18
|
+
|
19
|
+
# Set the minimum flow fraction
|
20
|
+
air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position)
|
21
|
+
|
22
|
+
return true
|
23
|
+
end
|
24
|
+
end
|
@@ -0,0 +1,32 @@
|
|
1
|
+
class ASHRAE9012019 < ASHRAE901
|
2
|
+
# @!group FanConstantVolume
|
3
|
+
|
4
|
+
# Determine the prototype fan pressure rise for a constant volume
|
5
|
+
# fan on an AirLoopHVAC based on the airflow of the system.
|
6
|
+
# @return [Double] the pressure rise (in H2O). Defaults
|
7
|
+
# to the logic from ASHRAE 90.1-2004 prototypes.
|
8
|
+
def fan_constant_volume_airloop_fan_pressure_rise(fan_constant_volume)
|
9
|
+
# Get the max flow rate from the fan.
|
10
|
+
maximum_flow_rate_m3_per_s = nil
|
11
|
+
if fan_constant_volume.maximumFlowRate.is_initialized
|
12
|
+
maximum_flow_rate_m3_per_s = fan_constant_volume.maximumFlowRate.get
|
13
|
+
elsif fan_constant_volume.autosizedMaximumFlowRate.is_initialized
|
14
|
+
maximum_flow_rate_m3_per_s = fan_constant_volume.autosizedMaximumFlowRate.get
|
15
|
+
else
|
16
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.prototype.FanConstantVolume', "For #{fan_constant_volume.name} max flow rate is not available, cannot apply prototype assumptions.")
|
17
|
+
return false
|
18
|
+
end
|
19
|
+
|
20
|
+
# Convert max flow rate to cfm
|
21
|
+
maximum_flow_rate_cfm = OpenStudio.convert(maximum_flow_rate_m3_per_s, 'm^3/s', 'cfm').get
|
22
|
+
|
23
|
+
# Determine the pressure rise
|
24
|
+
pressure_rise_in_h2o = if maximum_flow_rate_cfm < 7437
|
25
|
+
2.5
|
26
|
+
else # Over 7,437 cfm
|
27
|
+
4.09
|
28
|
+
end
|
29
|
+
|
30
|
+
return pressure_rise_in_h2o
|
31
|
+
end
|
32
|
+
end
|
data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb
ADDED
@@ -0,0 +1,33 @@
|
|
1
|
+
class ASHRAE9012019 < ASHRAE901
|
2
|
+
# @!group FanOnOff
|
3
|
+
|
4
|
+
# Determine the prototype fan pressure rise for an on off
|
5
|
+
# fan on an AirLoopHVAC or inside a unitary system
|
6
|
+
# based on the airflow of the system.
|
7
|
+
# @return [Double] the pressure rise (in H2O). Defaults
|
8
|
+
# to the logic from ASHRAE 90.1-2004 prototypes.
|
9
|
+
def fan_on_off_airloop_or_unitary_fan_pressure_rise(fan_on_off)
|
10
|
+
# Get the max flow rate from the fan.
|
11
|
+
maximum_flow_rate_m3_per_s = nil
|
12
|
+
if fan_on_off.maximumFlowRate.is_initialized
|
13
|
+
maximum_flow_rate_m3_per_s = fan_on_off.maximumFlowRate.get
|
14
|
+
elsif fan_on_off.autosizedMaximumFlowRate.is_initialized
|
15
|
+
maximum_flow_rate_m3_per_s = fan_on_off.autosizedMaximumFlowRate.get
|
16
|
+
else
|
17
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.prototype.FanOnOff', "For #{fan_on_off.name} max flow rate is not available, cannot apply prototype assumptions.")
|
18
|
+
return false
|
19
|
+
end
|
20
|
+
|
21
|
+
# Convert max flow rate to cfm
|
22
|
+
maximum_flow_rate_cfm = OpenStudio.convert(maximum_flow_rate_m3_per_s, 'm^3/s', 'cfm').get
|
23
|
+
|
24
|
+
# Determine the pressure rise
|
25
|
+
pressure_rise_in_h2o = if maximum_flow_rate_cfm < 7437
|
26
|
+
2.5
|
27
|
+
else # Over 7,437 cfm
|
28
|
+
4.09
|
29
|
+
end
|
30
|
+
|
31
|
+
return pressure_rise_in_h2o
|
32
|
+
end
|
33
|
+
end
|
@@ -0,0 +1,32 @@
|
|
1
|
+
class ASHRAE9012019 < ASHRAE901
|
2
|
+
# @!group FanVariableVolume
|
3
|
+
|
4
|
+
# Determine the prototype fan pressure rise for a variable volume
|
5
|
+
# fan on an AirLoopHVAC based on the airflow of the system.
|
6
|
+
# @return [Double] the pressure rise (in H2O). Defaults
|
7
|
+
# to the logic from ASHRAE 90.1-2004 prototypes.
|
8
|
+
def fan_variable_volume_airloop_fan_pressure_rise(fan_variable_volume)
|
9
|
+
# Get the max flow rate from the fan.
|
10
|
+
maximum_flow_rate_m3_per_s = nil
|
11
|
+
if fan_variable_volume.maximumFlowRate.is_initialized
|
12
|
+
maximum_flow_rate_m3_per_s = fan_variable_volume.maximumFlowRate.get
|
13
|
+
elsif fan_variable_volume.autosizedMaximumFlowRate.is_initialized
|
14
|
+
maximum_flow_rate_m3_per_s = fan_variable_volume.autosizedMaximumFlowRate.get
|
15
|
+
else
|
16
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.prototype.FanVariableVolume', "For #{fan_variable_volume.name} max flow rate is not available, cannot apply prototype assumptions.")
|
17
|
+
return false
|
18
|
+
end
|
19
|
+
|
20
|
+
# Convert max flow rate to cfm
|
21
|
+
maximum_flow_rate_cfm = OpenStudio.convert(maximum_flow_rate_m3_per_s, 'm^3/s', 'cfm').get
|
22
|
+
|
23
|
+
# Determine the pressure rise
|
24
|
+
pressure_rise_in_h2o = if maximum_flow_rate_cfm < 4648
|
25
|
+
4.0
|
26
|
+
else # Over 7,437 cfm
|
27
|
+
5.58
|
28
|
+
end
|
29
|
+
|
30
|
+
return pressure_rise_in_h2o
|
31
|
+
end
|
32
|
+
end
|
@@ -0,0 +1,25 @@
|
|
1
|
+
class ASHRAE9012019 < ASHRAE901
|
2
|
+
# @!group elevators
|
3
|
+
|
4
|
+
# Determines the percentage of the elevator cab
|
5
|
+
# lighting that is incandescent. The remainder
|
6
|
+
# is assumed to be LED. Defaults to 0% incandescent
|
7
|
+
# (100% LED), representing newer elevators.
|
8
|
+
def model_elevator_lighting_pct_incandescent(model)
|
9
|
+
pct_incandescent = 0.0 # 100% LED
|
10
|
+
return pct_incandescent
|
11
|
+
end
|
12
|
+
|
13
|
+
# Determines the power of the elevator ventilation fan.
|
14
|
+
# 90.1-2019 has a requirement
|
15
|
+
# for ventilation fan efficiency.
|
16
|
+
# @return [Double] the ventilaton fan power (W)
|
17
|
+
def model_elevator_fan_pwr(model, vent_rate_cfm)
|
18
|
+
vent_pwr_per_flow_w_per_cfm = 0.33
|
19
|
+
vent_pwr_w = vent_pwr_per_flow_w_per_cfm * vent_rate_cfm
|
20
|
+
# addendum 90.1-2007 aj has requirement on efficiency
|
21
|
+
vent_pwr_w = vent_pwr_w * 0.29 / 0.70
|
22
|
+
|
23
|
+
return vent_pwr_w
|
24
|
+
end
|
25
|
+
end
|
data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb
ADDED
@@ -0,0 +1,367 @@
|
|
1
|
+
class ASHRAE9012019 < ASHRAE901
|
2
|
+
# @!group Model
|
3
|
+
|
4
|
+
# Determine the prototypical economizer type for the model.
|
5
|
+
#
|
6
|
+
# @param model [OpenStudio::Model::Model] the model
|
7
|
+
# @param climate_zone [String] the climate zone
|
8
|
+
# @return [String] the economizer type. Possible values are:
|
9
|
+
# 'NoEconomizer'
|
10
|
+
# 'FixedDryBulb'
|
11
|
+
# 'FixedEnthalpy'
|
12
|
+
# 'DifferentialDryBulb'
|
13
|
+
# 'DifferentialEnthalpy'
|
14
|
+
# 'FixedDewPointAndDryBulb'
|
15
|
+
# 'ElectronicEnthalpy'
|
16
|
+
# 'DifferentialDryBulbAndEnthalpy'
|
17
|
+
def model_economizer_type(model, climate_zone)
|
18
|
+
economizer_type = case climate_zone
|
19
|
+
when 'ASHRAE 169-2006-0A',
|
20
|
+
'ASHRAE 169-2006-1A',
|
21
|
+
'ASHRAE 169-2006-2A',
|
22
|
+
'ASHRAE 169-2006-3A',
|
23
|
+
'ASHRAE 169-2006-4A',
|
24
|
+
'ASHRAE 169-2013-0A',
|
25
|
+
'ASHRAE 169-2013-1A',
|
26
|
+
'ASHRAE 169-2013-2A',
|
27
|
+
'ASHRAE 169-2013-3A',
|
28
|
+
'ASHRAE 169-2013-4A'
|
29
|
+
'DifferentialEnthalpy'
|
30
|
+
else
|
31
|
+
'DifferentialDryBulb'
|
32
|
+
end
|
33
|
+
return economizer_type
|
34
|
+
end
|
35
|
+
|
36
|
+
# Adjust model to comply with fenestration orientation requirements
|
37
|
+
#
|
38
|
+
# @code_sections [90.1-2013_5.5.4.5]
|
39
|
+
# @param [OpenStudio::Model::Model] OpenStudio model object
|
40
|
+
# @return [Boolean] Returns true if successful, false otherwise
|
41
|
+
def model_fenestration_orientation(model, climate_zone)
|
42
|
+
# Building rotation to meet the same code requirement for
|
43
|
+
# 90.1-2010 are kept
|
44
|
+
if model.getBuilding.standardsBuildingType.is_initialized
|
45
|
+
building_type = model.getBuilding.standardsBuildingType.get
|
46
|
+
|
47
|
+
case building_type
|
48
|
+
when 'Hospital'
|
49
|
+
# Rotate the building counter-clockwise
|
50
|
+
model_set_building_north_axis(model, 270.0)
|
51
|
+
when 'SmallHotel'
|
52
|
+
# Rotate the building clockwise
|
53
|
+
model_set_building_north_axis(model, 180)
|
54
|
+
end
|
55
|
+
end
|
56
|
+
|
57
|
+
wwr = false
|
58
|
+
# Section 6.2.1.2 in the ANSI/ASHRAE/IES Standard 90.1-2013 Determination
|
59
|
+
# of Energy Savings: Quantitative Analysis mentions that the SHGC trade-off
|
60
|
+
# path is most likely to be used by designers for compliance.
|
61
|
+
#
|
62
|
+
# The following adjustment are only made for models with simple glazing objects
|
63
|
+
non_simple_glazing = false
|
64
|
+
shgc_a = 0
|
65
|
+
model.getSpaces.each do |space|
|
66
|
+
# Get thermal zone multiplier
|
67
|
+
multiplier = space.thermalZone.get.multiplier
|
68
|
+
|
69
|
+
space.surfaces.each do |surface|
|
70
|
+
surface.subSurfaces.each do |subsurface|
|
71
|
+
# Get window subsurface type
|
72
|
+
subsurface_type = subsurface.subSurfaceType.to_s.downcase
|
73
|
+
|
74
|
+
# Window, glass doors
|
75
|
+
next unless (subsurface_type.include? 'window') || (subsurface_type.include? 'glass')
|
76
|
+
|
77
|
+
# Check if non simple glazing fenestration objects are used
|
78
|
+
subsurface_cons = subsurface.construction.get.to_Construction.get
|
79
|
+
non_simple_glazing = true unless subsurface_cons.layers[0].to_SimpleGlazing.is_initialized
|
80
|
+
|
81
|
+
if non_simple_glazing
|
82
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2013.model', 'Fenestration objects in the model use non-simple glazing models, fenestration requirements are not applied')
|
83
|
+
return false
|
84
|
+
end
|
85
|
+
|
86
|
+
# Get subsurface's simple glazing object
|
87
|
+
subsurface_shgc = subsurface_cons.layers[0].to_SimpleGlazing.get.solarHeatGainCoefficient
|
88
|
+
|
89
|
+
# Get subsurface area
|
90
|
+
subsurface_area = subsurface.grossArea * subsurface.multiplier * multiplier
|
91
|
+
|
92
|
+
# SHGC * Area
|
93
|
+
shgc_a += subsurface_shgc * subsurface_area
|
94
|
+
end
|
95
|
+
end
|
96
|
+
end
|
97
|
+
|
98
|
+
# Calculate West, East and total fenestration area
|
99
|
+
a_w = model_get_window_area_info_for_orientation(model, 'W', wwr: wwr)
|
100
|
+
a_e = model_get_window_area_info_for_orientation(model, 'E', wwr: wwr)
|
101
|
+
a_t = a_w + a_e + model_get_window_area_info_for_orientation(model, 'N', wwr: wwr) + model_get_window_area_info_for_orientation(model, 'S', wwr: wwr)
|
102
|
+
|
103
|
+
return true if a_t == 0.0
|
104
|
+
|
105
|
+
# For prototypes SHGC_c assumed to be the building's weighted average SHGC
|
106
|
+
shgc_c = shgc_a / a_t
|
107
|
+
shgc_c = shgc_c.round(2)
|
108
|
+
|
109
|
+
# West and East facing WWR
|
110
|
+
wwr_w = model_get_window_area_info_for_orientation(model, 'W', wwr: true)
|
111
|
+
wwr_e = model_get_window_area_info_for_orientation(model, 'E', wwr: true)
|
112
|
+
|
113
|
+
# Calculate new SHGC for west and east facing fenestration;
|
114
|
+
# Create new simple glazing object and assign it to all
|
115
|
+
# West and East fenestration
|
116
|
+
#
|
117
|
+
# Exception 5 is applied when applicable
|
118
|
+
shgc_w = 0
|
119
|
+
shgc_e = 0
|
120
|
+
|
121
|
+
# Determine requirement criteria
|
122
|
+
case climate_zone
|
123
|
+
when 'ASHRAE 169-2006-0A',
|
124
|
+
'ASHRAE 169-2006-0B',
|
125
|
+
'ASHRAE 169-2006-1A',
|
126
|
+
'ASHRAE 169-2006-1B',
|
127
|
+
'ASHRAE 169-2006-2A',
|
128
|
+
'ASHRAE 169-2006-2B',
|
129
|
+
'ASHRAE 169-2006-3A',
|
130
|
+
'ASHRAE 169-2006-3B',
|
131
|
+
'ASHRAE 169-2006-3C',
|
132
|
+
'ASHRAE 169-2013-0A',
|
133
|
+
'ASHRAE 169-2013-0B',
|
134
|
+
'ASHRAE 169-2013-1A',
|
135
|
+
'ASHRAE 169-2013-1B',
|
136
|
+
'ASHRAE 169-2013-2A',
|
137
|
+
'ASHRAE 169-2013-2B',
|
138
|
+
'ASHRAE 169-2013-3A',
|
139
|
+
'ASHRAE 169-2013-3B',
|
140
|
+
'ASHRAE 169-2013-3C'
|
141
|
+
criteria = 4
|
142
|
+
when 'ASHRAE 169-2006-4A',
|
143
|
+
'ASHRAE 169-2006-4B',
|
144
|
+
'ASHRAE 169-2006-4C',
|
145
|
+
'ASHRAE 169-2006-5A',
|
146
|
+
'ASHRAE 169-2006-5B',
|
147
|
+
'ASHRAE 169-2006-5C',
|
148
|
+
'ASHRAE 169-2006-6A',
|
149
|
+
'ASHRAE 169-2006-6B',
|
150
|
+
'ASHRAE 169-2006-7A',
|
151
|
+
'ASHRAE 169-2006-7B',
|
152
|
+
'ASHRAE 169-2006-8A',
|
153
|
+
'ASHRAE 169-2006-8B',
|
154
|
+
'ASHRAE 169-2013-4A',
|
155
|
+
'ASHRAE 169-2013-4B',
|
156
|
+
'ASHRAE 169-2013-4C',
|
157
|
+
'ASHRAE 169-2013-5A',
|
158
|
+
'ASHRAE 169-2013-5B',
|
159
|
+
'ASHRAE 169-2013-5C',
|
160
|
+
'ASHRAE 169-2013-6A',
|
161
|
+
'ASHRAE 169-2013-6B',
|
162
|
+
'ASHRAE 169-2013-7A',
|
163
|
+
'ASHRAE 169-2013-7B',
|
164
|
+
'ASHRAE 169-2013-8A',
|
165
|
+
'ASHRAE 169-2013-8B'
|
166
|
+
criteria = 5
|
167
|
+
else
|
168
|
+
return false
|
169
|
+
end
|
170
|
+
|
171
|
+
if !((a_w <= a_t / criteria) && (a_e <= a_t / criteria))
|
172
|
+
# Calculate new SHGC
|
173
|
+
if wwr_w > 0.2
|
174
|
+
shgc_w = a_t * shgc_c / (criteria * a_w)
|
175
|
+
end
|
176
|
+
if wwr_e > 0.2
|
177
|
+
shgc_e = a_t * shgc_c / (criteria * a_w)
|
178
|
+
end
|
179
|
+
|
180
|
+
# No SHGC adjustment needed
|
181
|
+
return true if shgc_w == 0 && shgc_e == 0
|
182
|
+
|
183
|
+
model.getSpaces.each do |space|
|
184
|
+
# Get thermal zone multiplier
|
185
|
+
multiplier = space.thermalZone.get.multiplier
|
186
|
+
|
187
|
+
space.surfaces.each do |surface|
|
188
|
+
# Proceed only for East and West facing surfaces that are required
|
189
|
+
# to have their SHGC adjusted
|
190
|
+
next unless (surface_cardinal_direction(surface) == 'W' && shgc_w > 0) ||
|
191
|
+
(surface_cardinal_direction(surface) == 'E' && shgc_e > 0)
|
192
|
+
|
193
|
+
surface.subSurfaces.each do |subsurface|
|
194
|
+
# Get window subsurface type
|
195
|
+
subsurface_type = subsurface.subSurfaceType.to_s.downcase
|
196
|
+
|
197
|
+
# Window, glass doors
|
198
|
+
next unless (subsurface_type.include? 'window') || (subsurface_type.include? 'glass')
|
199
|
+
|
200
|
+
new_shgc = surface_cardinal_direction(surface) == 'W' ? shgc_w : shgc_e
|
201
|
+
new_shgc = new_shgc.round(2)
|
202
|
+
|
203
|
+
# Get construction/simple glazing associated with the subsurface
|
204
|
+
subsurface_org_cons = subsurface.construction.get.to_Construction.get
|
205
|
+
subsurface_org_cons_mat = subsurface_org_cons.layers[0].to_SimpleGlazing.get
|
206
|
+
|
207
|
+
# Only proceed if new SHGC is different than orignal one
|
208
|
+
next unless (new_shgc - subsurface_org_cons_mat.solarHeatGainCoefficient).abs > 0
|
209
|
+
|
210
|
+
# Clone construction/simple glazing associated with the subsurface
|
211
|
+
subsurface_new_cons = subsurface_org_cons.clone(model).to_Construction.get
|
212
|
+
subsurface_new_cons.setName("#{subsurface.name} Wind Cons U-#{OpenStudio.convert(subsurface_org_cons_mat.uFactor, 'W/m^2*K', 'Btu/ft^2*h*R').get.round(2)} SHGC #{new_shgc}")
|
213
|
+
subsurface_new_cons_mat = subsurface_org_cons_mat.clone(model).to_SimpleGlazing.get
|
214
|
+
subsurface_new_cons_mat.setName("#{subsurface.name} Wind SG Mat U-#{OpenStudio.convert(subsurface_org_cons_mat.uFactor, 'W/m^2*K', 'Btu/ft^2*h*R').get.round(2)} SHGC #{new_shgc}")
|
215
|
+
subsurface_new_cons_mat.setSolarHeatGainCoefficient(new_shgc)
|
216
|
+
new_layers = OpenStudio::Model::MaterialVector.new
|
217
|
+
new_layers << subsurface_new_cons_mat
|
218
|
+
subsurface_new_cons.setLayers(new_layers)
|
219
|
+
|
220
|
+
# Assign new construction to sub surface
|
221
|
+
subsurface.setConstruction(subsurface_new_cons)
|
222
|
+
end
|
223
|
+
end
|
224
|
+
end
|
225
|
+
end
|
226
|
+
|
227
|
+
return true
|
228
|
+
end
|
229
|
+
|
230
|
+
# Is transfer air required?
|
231
|
+
#
|
232
|
+
# @code_sections [90.1-2019_6.5.7.1]
|
233
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
234
|
+
# @return [Boolean] true if transfer air is required, false otherwise
|
235
|
+
def model_transfer_air_required?(model)
|
236
|
+
return true
|
237
|
+
end
|
238
|
+
|
239
|
+
# Metal coiling door code minimum infiltration rate at 75 Pa
|
240
|
+
#
|
241
|
+
# @code_sections [90.1-2019_5.4.3.2]
|
242
|
+
# @param [String] Climate zone
|
243
|
+
# @return [Float] Minimum infiltration rate for metal coiling doors
|
244
|
+
def model_door_infil_flow_rate_metal_coiling_cfm_ft2(climate_zone)
|
245
|
+
case climate_zone
|
246
|
+
when 'ASHRAE 169-2006-7A',
|
247
|
+
'ASHRAE 169-2006-7B',
|
248
|
+
'ASHRAE 169-2006-8A',
|
249
|
+
'ASHRAE 169-2006-8B',
|
250
|
+
'ASHRAE 169-2013-7A',
|
251
|
+
'ASHRAE 169-2013-7B',
|
252
|
+
'ASHRAE 169-2013-8A',
|
253
|
+
'ASHRAE 169-2013-8B'
|
254
|
+
return 0.4
|
255
|
+
else
|
256
|
+
return 1.0
|
257
|
+
end
|
258
|
+
end
|
259
|
+
|
260
|
+
# Implement occupancy based lighting level threshold (0.02 W/sqft). This is only for ASHRAE 90.1 2016 onwards.
|
261
|
+
#
|
262
|
+
# @code_sections [90.1-2016_9.4.1.1.h/i]
|
263
|
+
# @author Xuechen (Jerry) Lei, PNNL
|
264
|
+
# @param model [OpenStudio::Model::Model] OpenStudio Model
|
265
|
+
#
|
266
|
+
def model_add_lights_shutoff(model)
|
267
|
+
zones = model.getThermalZones
|
268
|
+
num_zones = 0
|
269
|
+
business_sch_name = prototype_input['business_schedule']
|
270
|
+
return if business_sch_name.nil? # This is only for 10 prototypes that do not have continuous operation.
|
271
|
+
|
272
|
+
# Add business schedule
|
273
|
+
model_add_schedule(model, business_sch_name)
|
274
|
+
|
275
|
+
# Add EMS object for business schedule variable
|
276
|
+
business_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Schedule Value')
|
277
|
+
business_sensor.setKeyName(business_sch_name)
|
278
|
+
business_sensor.setName('Business_Sensor')
|
279
|
+
business_sensor_name = business_sensor.name.to_s
|
280
|
+
|
281
|
+
zones.each do |zone|
|
282
|
+
spaces = zone.spaces
|
283
|
+
if spaces.length != 1
|
284
|
+
puts 'warning, there are more than one spaces in the zone, need to confirm the implementation'
|
285
|
+
end
|
286
|
+
space = spaces[0]
|
287
|
+
space_lights = space.lights
|
288
|
+
if space_lights.empty?
|
289
|
+
space_lights = space.spaceType.get.lights
|
290
|
+
end
|
291
|
+
space_people = space.people
|
292
|
+
if space_people.empty?
|
293
|
+
space_people = space.spaceType.get.people
|
294
|
+
end
|
295
|
+
|
296
|
+
next if space_lights.empty? # skip space with no lights
|
297
|
+
|
298
|
+
zone_name = zone.name.to_s
|
299
|
+
next if zone_name =~ /data\s*center/i # skip data centers
|
300
|
+
|
301
|
+
# EnergyPlus v9.4 name change for EMS actuators
|
302
|
+
# https://github.com/NREL/OpenStudio/pull/4104
|
303
|
+
if model.version < OpenStudio::VersionString.new('3.1.0')
|
304
|
+
light_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Lights Electric Power')
|
305
|
+
else
|
306
|
+
light_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Lights Electricity Rate')
|
307
|
+
end
|
308
|
+
light_sensor.setKeyName(zone_name)
|
309
|
+
light_sensor.setName("#{zone_name}_LSr".gsub(/[\s-]/, ''))
|
310
|
+
light_sensor_name = light_sensor.name.to_s
|
311
|
+
|
312
|
+
floor_area = OpenStudio::Model::EnergyManagementSystemInternalVariable.new(model, 'Zone Floor Area')
|
313
|
+
floor_area.setInternalDataIndexKeyName(zone_name)
|
314
|
+
floor_area.setName("#{zone_name}_Area".gsub(/[\s-]/, ''))
|
315
|
+
floor_area_name = floor_area.name.to_s
|
316
|
+
|
317
|
+
# account for multiple lights (also work for single light)
|
318
|
+
big_light = space_lights[0] # find the light with highest power (assuming specified by watts/area)
|
319
|
+
space_lights.each do |light_x|
|
320
|
+
big_light_power = big_light.definition.to_LightsDefinition.get.wattsperSpaceFloorArea.to_f
|
321
|
+
light_x_power = light_x.definition.to_LightsDefinition.get.wattsperSpaceFloorArea.to_f
|
322
|
+
if light_x_power > big_light_power
|
323
|
+
big_light = light_x
|
324
|
+
end
|
325
|
+
end
|
326
|
+
|
327
|
+
add_lights_prog_0 = ''
|
328
|
+
add_lights_prog_null = ''
|
329
|
+
light_id = 0
|
330
|
+
space_lights.each do |light_x|
|
331
|
+
light_id += 1
|
332
|
+
# EnergyPlus v9.4 name change for EMS actuators
|
333
|
+
# https://github.com/NREL/OpenStudio/pull/4104
|
334
|
+
if model.version < OpenStudio::VersionString.new('3.1.0')
|
335
|
+
light_x_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(light_x, 'Lights', 'Electric Power Level')
|
336
|
+
else
|
337
|
+
light_x_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(light_x, 'Lights', 'Electricity Rate')
|
338
|
+
end
|
339
|
+
light_x_actuator.setName("#{zone_name}_Light#{light_id}_Actuator".gsub(/[\s-]/, ''))
|
340
|
+
light_x_actuator_name = light_x_actuator.name.to_s
|
341
|
+
add_lights_prog_null += "\n SET #{light_x_actuator_name} = NULL,"
|
342
|
+
if light_x == big_light
|
343
|
+
add_lights_prog_0 += "\n SET #{light_x_actuator_name} = 0.02*#{floor_area_name}/0.09290304,"
|
344
|
+
next
|
345
|
+
end
|
346
|
+
add_lights_prog_0 += "\n SET #{light_x_actuator_name} = 0,"
|
347
|
+
end
|
348
|
+
|
349
|
+
light_ems_prog = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
350
|
+
light_ems_prog.setName("SET_#{zone_name}_Light_EMS_Program".gsub(/[\s-]/, ''))
|
351
|
+
light_ems_prog_body = <<-EMS
|
352
|
+
SET #{light_sensor_name}_IP=0.093*#{light_sensor_name}/#{floor_area_name},
|
353
|
+
IF (#{business_sensor_name} <= 0) && (#{light_sensor_name}_IP >= 0.02),#{add_lights_prog_0}
|
354
|
+
ELSE,#{add_lights_prog_null}
|
355
|
+
ENDIF
|
356
|
+
EMS
|
357
|
+
light_ems_prog.setBody(light_ems_prog_body)
|
358
|
+
|
359
|
+
light_ems_prog_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
|
360
|
+
light_ems_prog_manager.setName("SET_#{zone_name}_Light_EMS_Program_Manager")
|
361
|
+
light_ems_prog_manager.setCallingPoint('AfterPredictorAfterHVACManagers')
|
362
|
+
light_ems_prog_manager.addProgram(light_ems_prog)
|
363
|
+
end
|
364
|
+
|
365
|
+
return true
|
366
|
+
end
|
367
|
+
end
|