openstudio-standards 0.8.3 → 0.8.5.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.osm +30 -30
- data/data/geometry/ASHRAECourthouse.osm +22 -22
- data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
- data/data/geometry/DEER_Asm.osm +1 -1
- data/data/geometry/DEER_ECC.osm +1 -1
- data/data/geometry/DEER_EPr.osm +1 -1
- data/data/geometry/DEER_ERC.osm +1 -1
- data/data/geometry/DEER_ESe.osm +1 -1
- data/data/geometry/DEER_EUn.osm +1 -1
- data/data/geometry/DEER_Hsp.osm +1 -1
- data/data/geometry/DEER_Htl.osm +1 -1
- data/data/geometry/DEER_MBT.osm +1 -1
- data/data/geometry/DEER_MFm.osm +1 -1
- data/data/geometry/DEER_Nrs.osm +1 -1
- data/data/geometry/DEER_OfL.osm +1 -1
- data/data/geometry/DEER_OfS.osm +1 -1
- data/data/geometry/DEER_RFF.osm +1 -1
- data/data/geometry/DEER_RSD.osm +1 -1
- data/data/geometry/DEER_Rt3.osm +1 -1
- data/data/geometry/DEER_RtS.osm +1 -1
- data/data/standards/export_OpenStudio_libraries.rb +2 -3
- data/data/standards/test_performance_expected_dd_results.csv +42 -42
- data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
- data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
- data/lib/openstudio-standards/btap/activity.rb +480 -0
- data/lib/openstudio-standards/btap/attributes.rb +166 -0
- data/lib/openstudio-standards/btap/bridging.rb +561 -1402
- data/lib/openstudio-standards/btap/btap.rb +4 -2
- data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
- data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
- data/lib/openstudio-standards/btap/common_paths.rb +81 -0
- data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
- data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/materials_hvac.csv +1686 -0
- data/lib/openstudio-standards/btap/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +469 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +173 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +354 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +215 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +156 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +15 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +27 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/btap/geometry.rb +86 -6
- data/lib/openstudio-standards/btap/structure.rb +657 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
- data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
- data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
- data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
- data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
- data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
- data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
- data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
- data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
- data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
- data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
- data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
- data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
- data/lib/openstudio-standards/hvac/components/component.rb +39 -0
- data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
- data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
- data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
- data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
- data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
- data/lib/openstudio-standards/hvac/conversions.rb +222 -0
- data/lib/openstudio-standards/hvac/curves.rb +192 -0
- data/lib/openstudio-standards/hvac/helpers.rb +357 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
- data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
- data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
- data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
- data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
- data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
- data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
- data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
- data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
- data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
- data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
- data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
- data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
- data/lib/openstudio-standards/standards/Standards.Model.rb +45 -20
- data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
- data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +7 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
- data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
- data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +21 -37
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +115 -112
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +637 -249
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +75 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +25 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +18 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +68 -150
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +444 -134
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +17 -8
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +206 -32
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +75 -43
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
- data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards/weather/stat_file.rb +2 -2
- data/lib/openstudio-standards.rb +67 -38
- metadata +141 -50
- data/lib/openstudio-standards/hvac/components/create.rb +0 -169
- data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
- data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
|
@@ -81,7 +81,8 @@ class NECB2011
|
|
|
81
81
|
system_data,
|
|
82
82
|
determine_control_zone(zones),
|
|
83
83
|
necb_reference_hp: necb_reference_hp,
|
|
84
|
-
necb_reference_hp_supp_fuel: necb_reference_hp_supp_fuel
|
|
84
|
+
necb_reference_hp_supp_fuel: necb_reference_hp_supp_fuel,
|
|
85
|
+
hw_loop: hw_loop)
|
|
85
86
|
# Add Zone equipment
|
|
86
87
|
zones.each do |zone| # Zone sizing temperature difference
|
|
87
88
|
sizing_zone = zone.sizingZone
|
|
@@ -101,11 +102,10 @@ class NECB2011
|
|
|
101
102
|
hw_loop,
|
|
102
103
|
model,
|
|
103
104
|
zone)
|
|
104
|
-
|
|
105
105
|
end
|
|
106
106
|
else
|
|
107
107
|
zones.each do |zone|
|
|
108
|
-
air_loop = add_system_3_and_8_airloop(heating_coil_type, model, system_data, zone, necb_reference_hp: necb_reference_hp, necb_reference_hp_supp_fuel: necb_reference_hp_supp_fuel)
|
|
108
|
+
air_loop = add_system_3_and_8_airloop(heating_coil_type, model, system_data, zone, necb_reference_hp: necb_reference_hp, necb_reference_hp_supp_fuel: necb_reference_hp_supp_fuel, hw_loop: hw_loop)
|
|
109
109
|
add_sys3_and_8_zone_equip(air_loop,
|
|
110
110
|
baseboard_type,
|
|
111
111
|
hw_loop,
|
|
@@ -118,19 +118,20 @@ class NECB2011
|
|
|
118
118
|
sys_name_pars['sys_clg'] = 'dx'
|
|
119
119
|
sys_name_pars['sys_clg'] = 'ashp' if necb_reference_hp
|
|
120
120
|
sys_name_pars['sys_htg'] = heating_coil_type
|
|
121
|
-
sys_name_pars['sys_htg'] = 'ashp' if necb_reference_hp
|
|
121
|
+
sys_name_pars['sys_htg'] = 'ashp>c-g' if necb_reference_hp && (necb_reference_hp_supp_fuel == "NaturalGas" || necb_reference_hp_supp_fuel == "Gas")
|
|
122
|
+
sys_name_pars['sys_htg'] = 'ashp>c-e' if necb_reference_hp && (necb_reference_hp_supp_fuel == "Electricity" || necb_reference_hp_supp_fuel == "Electric" || necb_reference_hp_supp_fuel == "FuelOilNo2")
|
|
123
|
+
sys_name_pars['sys_htg'] = 'ashp>c-hw' if necb_reference_hp && (necb_reference_hp_supp_fuel == "Hot Water" || necb_reference_hp_supp_fuel == "HotWater")
|
|
122
124
|
sys_name_pars['sys_sf'] = 'cv'
|
|
123
125
|
sys_name_pars['zone_htg'] = baseboard_type
|
|
124
126
|
sys_name_pars['zone_clg'] = 'none'
|
|
125
127
|
sys_name_pars['sys_rf'] = 'none'
|
|
126
|
-
assign_base_sys_name(air_loop,
|
|
128
|
+
return assign_base_sys_name( air_loop: air_loop,
|
|
127
129
|
sys_abbr: 'sys_3',
|
|
128
130
|
sys_oa: 'mixed',
|
|
129
131
|
sys_name_pars: sys_name_pars)
|
|
130
|
-
return true
|
|
131
132
|
end
|
|
132
133
|
|
|
133
|
-
def add_system_3_and_8_airloop(heating_coil_type, model, system_data, control_zone, necb_reference_hp:false, necb_reference_hp_supp_fuel:'DefaultFuel')
|
|
134
|
+
def add_system_3_and_8_airloop(heating_coil_type, model, system_data, control_zone, necb_reference_hp:false, necb_reference_hp_supp_fuel:'DefaultFuel', necb_reference_hp_fancoil: false, hw_loop: nil)
|
|
134
135
|
# System Type 3: PSZ-AC
|
|
135
136
|
# This measure creates:
|
|
136
137
|
# -a constant volume packaged single-zone A/C unit
|
|
@@ -160,12 +161,14 @@ class NECB2011
|
|
|
160
161
|
sizing_zone.setZoneHeatingSizingFactor(system_data[:ZoneHeatingSizingFactor])
|
|
161
162
|
end
|
|
162
163
|
|
|
163
|
-
if necb_reference_hp
|
|
164
|
+
#if necb_reference_hp
|
|
164
165
|
#AirLoopHVACUnitaryHeatPumpAirToAir needs FanOnOff in order for the fan to turn off during off hours
|
|
165
|
-
|
|
166
|
-
else
|
|
167
|
-
|
|
168
|
-
end
|
|
166
|
+
# fan = OpenStudio::Model::FanOnOff.new(model, always_on)
|
|
167
|
+
#else
|
|
168
|
+
# fan = OpenStudio::Model::FanConstantVolume.new(model, always_on)
|
|
169
|
+
#end
|
|
170
|
+
# Not using unitary heat pump model until it works with backup hot water coils. Fan stays as contant volume.# Not using unitary heat pump model until it works with backup hot water coils. Fan stays as contant volume.
|
|
171
|
+
fan = OpenStudio::Model::FanConstantVolume.new(model, always_on)
|
|
169
172
|
|
|
170
173
|
# Set up DX coil
|
|
171
174
|
if necb_reference_hp #NECB curve characteristics
|
|
@@ -178,10 +181,13 @@ class NECB2011
|
|
|
178
181
|
|
|
179
182
|
raise("Flag 'necb_reference_hp' is set to true while parameter 'heating_coil_type' is not set to DX") if (necb_reference_hp && (heating_coil_type != 'DX'))
|
|
180
183
|
case heating_coil_type
|
|
181
|
-
when 'Electric' # electric coil
|
|
184
|
+
when 'Electric', 'Electricity', "FuelOilNo2" # electric coil
|
|
182
185
|
htg_coil = OpenStudio::Model::CoilHeatingElectric.new(model, always_on)
|
|
183
|
-
when 'Gas'
|
|
186
|
+
when 'Gas', 'NaturalGas'
|
|
184
187
|
htg_coil = OpenStudio::Model::CoilHeatingGas.new(model, always_on)
|
|
188
|
+
when 'Hot Water', 'HotWater'
|
|
189
|
+
htg_coil = OpenStudio::Model::CoilHeatingWater.new(model, always_on)
|
|
190
|
+
hw_loop.addDemandBranchForComponent(htg_coil)
|
|
185
191
|
when 'DX'
|
|
186
192
|
#create main DX heating coil
|
|
187
193
|
htg_coil = add_onespeed_htg_DX_coil(model, always_on)
|
|
@@ -210,31 +216,33 @@ class NECB2011
|
|
|
210
216
|
# Add the components to the air loop
|
|
211
217
|
# in order from closest to zone to furthest from zone
|
|
212
218
|
supply_inlet_node = air_loop.supplyInletNode
|
|
219
|
+
fan.addToNode(supply_inlet_node)
|
|
213
220
|
if necb_reference_hp
|
|
214
|
-
|
|
215
221
|
#create supplemental heating coil based on default regional fuel type
|
|
216
222
|
if necb_reference_hp_supp_fuel == 'DefaultFuel'
|
|
217
223
|
epw = OpenStudio::EpwFile.new(model.weatherFile.get.path.get)
|
|
218
224
|
necb_reference_hp_supp_fuel = @standards_data['regional_fuel_use'].detect { |fuel_sources| fuel_sources['state_province_regions'].include?(epw.stateProvinceRegion) }['fueltype_set']
|
|
219
225
|
end
|
|
220
|
-
if necb_reference_hp_supp_fuel == 'NaturalGas'
|
|
226
|
+
if necb_reference_hp_supp_fuel == 'NaturalGas' || necb_reference_hp_supp_fuel == 'Gas'
|
|
221
227
|
supplemental_htg_coil = OpenStudio::Model::CoilHeatingGas.new(model, always_on)
|
|
222
|
-
elsif necb_reference_hp_supp_fuel == 'Electricity'
|
|
228
|
+
elsif necb_reference_hp_supp_fuel == 'Electricity' || necb_reference_hp_supp_fuel == 'Electric' || necb_reference_hp_supp_fuel == 'FuelOilNo2'
|
|
223
229
|
supplemental_htg_coil = OpenStudio::Model::CoilHeatingElectric.new(model, always_on)
|
|
224
|
-
|
|
230
|
+
elsif necb_reference_hp_supp_fuel == 'Hot Water' || necb_reference_hp_supp_fuel == "HotWater"
|
|
231
|
+
supplemental_htg_coil = OpenStudio::Model::CoilHeatingWater.new(model, always_on)
|
|
232
|
+
hw_loop.addDemandBranchForComponent(supplemental_htg_coil)
|
|
233
|
+
else
|
|
225
234
|
raise('Invalid fuel type selected for heat pump supplemental coil')
|
|
226
235
|
end
|
|
227
236
|
# This method will seem like an error in number of args..but this is due to swig voodoo.
|
|
228
|
-
air_to_air_heatpump = OpenStudio::Model::AirLoopHVACUnitaryHeatPumpAirToAir.new(model, always_on, fan, htg_coil, clg_coil, supplemental_htg_coil)
|
|
229
|
-
air_to_air_heatpump.setName("#{control_zone.name} ASHP")
|
|
230
|
-
air_to_air_heatpump.setControllingZone(control_zone)
|
|
231
|
-
air_to_air_heatpump.setSupplyAirFanOperatingModeSchedule(always_on)
|
|
232
|
-
air_to_air_heatpump.addToNode(supply_inlet_node)
|
|
233
|
-
|
|
234
|
-
fan.addToNode(supply_inlet_node)
|
|
235
|
-
htg_coil.addToNode(supply_inlet_node)
|
|
236
|
-
clg_coil.addToNode(supply_inlet_node)
|
|
237
|
+
#air_to_air_heatpump = OpenStudio::Model::AirLoopHVACUnitaryHeatPumpAirToAir.new(model, always_on, fan, htg_coil, clg_coil, supplemental_htg_coil)
|
|
238
|
+
#air_to_air_heatpump.setName("#{control_zone.name} ASHP")
|
|
239
|
+
#air_to_air_heatpump.setControllingZone(control_zone)
|
|
240
|
+
#air_to_air_heatpump.setSupplyAirFanOperatingModeSchedule(always_on)
|
|
241
|
+
#air_to_air_heatpump.addToNode(supply_inlet_node)
|
|
242
|
+
supplemental_htg_coil.addToNode(supply_inlet_node)
|
|
237
243
|
end
|
|
244
|
+
htg_coil.addToNode(supply_inlet_node)
|
|
245
|
+
clg_coil.addToNode(supply_inlet_node)
|
|
238
246
|
oa_system.addToNode(supply_inlet_node)
|
|
239
247
|
|
|
240
248
|
# Add a setpoint manager single zone reheat to control the
|
|
@@ -54,9 +54,7 @@ class NECB2011
|
|
|
54
54
|
# NOTE: This is the same as system type 3 (single zone make-up air unit and single zone rooftop unit are both PSZ systems)
|
|
55
55
|
# SHOULD WE COMBINE sys3 and sys4 into one script?
|
|
56
56
|
#
|
|
57
|
-
|
|
58
|
-
# Todo change this when control zone method is working.
|
|
59
|
-
control_zone = zones.first
|
|
57
|
+
control_zone = determine_control_zone(zones)
|
|
60
58
|
|
|
61
59
|
always_on = model.alwaysOnDiscreteSchedule
|
|
62
60
|
|
|
@@ -83,12 +81,14 @@ class NECB2011
|
|
|
83
81
|
sizing_zone.setZoneHeatingSizingFactor(system_data[:ZoneHeatingSizingFactor])
|
|
84
82
|
end
|
|
85
83
|
|
|
86
|
-
if necb_reference_hp
|
|
84
|
+
#if necb_reference_hp
|
|
87
85
|
# AirLoopHVACUnitaryHeatPumpAirToAir needs FanOnOff in order for the fan to turn off during off hours
|
|
88
|
-
|
|
89
|
-
else
|
|
90
|
-
|
|
91
|
-
end
|
|
86
|
+
# fan = OpenStudio::Model::FanOnOff.new(model, always_on)
|
|
87
|
+
#else
|
|
88
|
+
# fan = OpenStudio::Model::FanConstantVolume.new(model, always_on)
|
|
89
|
+
#end
|
|
90
|
+
# Not using unitary heat pump model until it works with backup hot water coils. Fan stays as contant volume.
|
|
91
|
+
fan = OpenStudio::Model::FanConstantVolume.new(model, always_on)
|
|
92
92
|
|
|
93
93
|
# Set up DX coil with NECB performance curve characteristics;
|
|
94
94
|
clg_coil = add_onespeed_DX_coil(model, always_on)
|
|
@@ -96,13 +96,16 @@ class NECB2011
|
|
|
96
96
|
clg_coil.setName('CoilCoolingDXSingleSpeed_ashp') if necb_reference_hp
|
|
97
97
|
|
|
98
98
|
raise("Flag 'necb_reference_hp' is set to true while parameter 'heating_coil_type' is not set to DX") if (necb_reference_hp && (heating_coil_type != 'DX'))
|
|
99
|
-
if heating_coil_type == 'Electric' # electric coil
|
|
99
|
+
if heating_coil_type == 'Electric' || heating_coil_type == 'FuelOilNo2' # electric coil
|
|
100
100
|
htg_coil = OpenStudio::Model::CoilHeatingElectric.new(model, always_on)
|
|
101
101
|
elsif heating_coil_type == 'Gas'
|
|
102
102
|
htg_coil = OpenStudio::Model::CoilHeatingGas.new(model, always_on)
|
|
103
103
|
elsif heating_coil_type == 'DX'
|
|
104
104
|
htg_coil = add_onespeed_htg_DX_coil(model, always_on)
|
|
105
105
|
htg_coil.setName('CoilHeatingDXSingleSpeed_ashp')
|
|
106
|
+
elsif heating_coil_type == 'Hot Water'
|
|
107
|
+
htg_coil = OpenStudio::Model::CoilHeatingWater.new(model, always_on)
|
|
108
|
+
hw_loop.addDemandBranchForComponent(htg_coil)
|
|
106
109
|
end
|
|
107
110
|
|
|
108
111
|
# TO DO: other fuel-fired heating coil types? (not available in OpenStudio/E+ - may need to play with efficiency to mimic other fuel types)
|
|
@@ -121,6 +124,7 @@ class NECB2011
|
|
|
121
124
|
# Add the components to the air loop
|
|
122
125
|
# in order from closest to zone to furthest from zone
|
|
123
126
|
supply_inlet_node = air_loop.supplyInletNode
|
|
127
|
+
fan.addToNode(supply_inlet_node)
|
|
124
128
|
if necb_reference_hp
|
|
125
129
|
#create supplemental heating coil based on default regional fuel type
|
|
126
130
|
if necb_reference_hp_supp_fuel == 'DefaultFuel'
|
|
@@ -131,21 +135,27 @@ class NECB2011
|
|
|
131
135
|
supplemental_htg_coil = OpenStudio::Model::CoilHeatingGas.new(model, always_on)
|
|
132
136
|
elsif necb_reference_hp_supp_fuel == 'Electricity' or necb_reference_hp_supp_fuel == 'FuelOilNo2'
|
|
133
137
|
supplemental_htg_coil = OpenStudio::Model::CoilHeatingElectric.new(model, always_on)
|
|
134
|
-
|
|
138
|
+
elsif necb_reference_hp_supp_fuel == 'Hot Water'
|
|
139
|
+
supplemental_htg_coil = OpenStudio::Model::CoilHeatingWater.new(model, always_on)
|
|
140
|
+
hw_loop.addDemandBranchForComponent(supplemental_htg_coil)
|
|
141
|
+
else
|
|
135
142
|
raise('Invalid fuel type selected for heat pump supplemental coil')
|
|
136
143
|
end
|
|
144
|
+
supplemental_htg_coil.addToNode(supply_inlet_node)
|
|
137
145
|
# This method will seem like an error in number of args..but this is due to swig voodoo.
|
|
138
|
-
air_to_air_heatpump = OpenStudio::Model::AirLoopHVACUnitaryHeatPumpAirToAir.new(model, always_on, fan, htg_coil, clg_coil, supplemental_htg_coil)
|
|
139
|
-
air_to_air_heatpump.setName("#{control_zone.name} ASHP")
|
|
140
|
-
air_to_air_heatpump.setControllingZone(control_zone)
|
|
141
|
-
air_to_air_heatpump.setSupplyAirFanOperatingModeSchedule(always_on)
|
|
142
|
-
air_to_air_heatpump.addToNode(supply_inlet_node)
|
|
143
|
-
else
|
|
144
|
-
fan.addToNode(supply_inlet_node)
|
|
145
|
-
htg_coil.addToNode(supply_inlet_node)
|
|
146
|
-
clg_coil.addToNode(supply_inlet_node)
|
|
147
|
-
|
|
146
|
+
#air_to_air_heatpump = OpenStudio::Model::AirLoopHVACUnitaryHeatPumpAirToAir.new(model, always_on, fan, htg_coil, clg_coil, supplemental_htg_coil)
|
|
147
|
+
#air_to_air_heatpump.setName("#{control_zone.name} ASHP")
|
|
148
|
+
#air_to_air_heatpump.setControllingZone(control_zone)
|
|
149
|
+
#air_to_air_heatpump.setSupplyAirFanOperatingModeSchedule(always_on)
|
|
150
|
+
#air_to_air_heatpump.addToNode(supply_inlet_node)
|
|
148
151
|
end
|
|
152
|
+
htg_coil.addToNode(supply_inlet_node)
|
|
153
|
+
clg_coil.addToNode(supply_inlet_node)
|
|
154
|
+
#fan.addToNode(supply_inlet_node)
|
|
155
|
+
#htg_coil.addToNode(supply_inlet_node)
|
|
156
|
+
#clg_coil.addToNode(supply_inlet_node)
|
|
157
|
+
#supplemental_htg_coil.addToNode(supply_inlet_node) if necb_reference_hp
|
|
158
|
+
|
|
149
159
|
oa_system.addToNode(supply_inlet_node)
|
|
150
160
|
# Add a setpoint manager single zone reheat to control the
|
|
151
161
|
# supply air temperature based on the needs of this zone
|
|
@@ -198,17 +208,18 @@ class NECB2011
|
|
|
198
208
|
sys_name_pars['sys_clg'] = 'dx'
|
|
199
209
|
sys_name_pars['sys_clg'] = 'ashp' if necb_reference_hp
|
|
200
210
|
sys_name_pars['sys_htg'] = heating_coil_type
|
|
201
|
-
sys_name_pars['sys_htg'] = 'ashp' if necb_reference_hp
|
|
211
|
+
sys_name_pars['sys_htg'] = 'ashp>c-g' if necb_reference_hp and necb_reference_hp_supp_fuel == "NaturalGas"
|
|
212
|
+
sys_name_pars['sys_htg'] = 'ashp>c-e' if necb_reference_hp and necb_reference_hp_supp_fuel == "Electricity"
|
|
213
|
+
sys_name_pars['sys_htg'] = 'ashp>c-hw' if necb_reference_hp and necb_reference_hp_supp_fuel == "Hot Water"
|
|
202
214
|
sys_name_pars['sys_sf'] = 'cv'
|
|
203
215
|
sys_name_pars['zone_htg'] = baseboard_type
|
|
204
216
|
sys_name_pars['zone_clg'] = 'none'
|
|
205
217
|
sys_name_pars['sys_rf'] = 'none'
|
|
206
|
-
assign_base_sys_name(air_loop,
|
|
218
|
+
return assign_base_sys_name(air_loop: air_loop,
|
|
207
219
|
sys_abbr: 'sys_4',
|
|
208
220
|
sys_oa: 'mixed',
|
|
209
221
|
sys_name_pars: sys_name_pars)
|
|
210
222
|
|
|
211
|
-
return true
|
|
212
223
|
end
|
|
213
224
|
# end add_sys4_single_zone_make_up_air_unit_with_baseboard_heating
|
|
214
225
|
end
|
|
@@ -138,7 +138,6 @@ class NECB2011
|
|
|
138
138
|
vav_terminal.setFixedMinimumAirFlowRate(system_data[:ZoneVAVMinFlowFactorPerFloorArea] * zone.floorArea)
|
|
139
139
|
vav_terminal.setMaximumReheatAirTemperature(system_data[:ZoneVAVMaxReheatTemp])
|
|
140
140
|
vav_terminal.setDamperHeatingAction(system_data[:ZoneVAVDamperAction])
|
|
141
|
-
|
|
142
141
|
end
|
|
143
142
|
sys_name_pars = {}
|
|
144
143
|
sys_name_pars['sys_hr'] = 'none'
|
|
@@ -148,7 +147,7 @@ class NECB2011
|
|
|
148
147
|
sys_name_pars['zone_htg'] = baseboard_type
|
|
149
148
|
sys_name_pars['zone_clg'] = 'none'
|
|
150
149
|
sys_name_pars['sys_rf'] = 'vv'
|
|
151
|
-
assign_base_sys_name(air_loop,
|
|
150
|
+
assign_base_sys_name(air_loop: air_loop,
|
|
152
151
|
sys_abbr: 'sys_6',
|
|
153
152
|
sys_oa: 'mixed',
|
|
154
153
|
sys_name_pars: sys_name_pars)
|
|
@@ -411,11 +410,14 @@ class NECB2011
|
|
|
411
410
|
epw = OpenStudio::EpwFile.new(model.weatherFile.get.path.get)
|
|
412
411
|
necb_reference_hp_supp_fuel = @standards_data['regional_fuel_use'].detect { |fuel_sources| fuel_sources['state_province_regions'].include?(epw.stateProvinceRegion) }['fueltype_set']
|
|
413
412
|
end
|
|
414
|
-
if necb_reference_hp_supp_fuel == 'NaturalGas'
|
|
413
|
+
if necb_reference_hp_supp_fuel == 'NaturalGas' || necb_reference_hp_supp_fuel == 'Gas'
|
|
415
414
|
rh_coil = OpenStudio::Model::CoilHeatingGas.new(model, always_on)
|
|
416
|
-
elsif necb_reference_hp_supp_fuel == 'Electricity'
|
|
415
|
+
elsif necb_reference_hp_supp_fuel == 'Electricity' || necb_reference_hp_supp_fuel == 'Electric' || necb_reference_hp_supp_fuel == 'FuelOilNo2'
|
|
417
416
|
rh_coil = OpenStudio::Model::CoilHeatingElectric.new(model, always_on)
|
|
418
|
-
|
|
417
|
+
elsif necb_reference_hp_supp_fuel == 'Hot Water' || necb_reference_hp_supp_fuel == 'HotWater'
|
|
418
|
+
rh_coil = OpenStudio::Model::CoilHeatingWater.new(model, always_on)
|
|
419
|
+
hw_loop.addDemandBranchForComponent(rh_coil)
|
|
420
|
+
else
|
|
419
421
|
raise('Invalid fuel type selected for heat pump supplemental coil')
|
|
420
422
|
end
|
|
421
423
|
cav_rh_terminal = OpenStudio::Model::AirTerminalSingleDuctConstantVolumeReheat.new(model, always_on, rh_coil)
|
|
@@ -429,7 +431,7 @@ class NECB2011
|
|
|
429
431
|
sys_name_pars['zone_htg'] = baseboard_type
|
|
430
432
|
sys_name_pars['zone_clg'] = 'none'
|
|
431
433
|
sys_name_pars['sys_rf'] = 'cv'
|
|
432
|
-
assign_base_sys_name(air_loop,
|
|
434
|
+
assign_base_sys_name(air_loop: air_loop,
|
|
433
435
|
sys_abbr: 'sys_6',
|
|
434
436
|
sys_oa: 'mixed',
|
|
435
437
|
sys_name_pars: sys_name_pars)
|