openstudio-standards 0.8.3 → 0.8.5.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.osm +30 -30
- data/data/geometry/ASHRAECourthouse.osm +22 -22
- data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
- data/data/geometry/DEER_Asm.osm +1 -1
- data/data/geometry/DEER_ECC.osm +1 -1
- data/data/geometry/DEER_EPr.osm +1 -1
- data/data/geometry/DEER_ERC.osm +1 -1
- data/data/geometry/DEER_ESe.osm +1 -1
- data/data/geometry/DEER_EUn.osm +1 -1
- data/data/geometry/DEER_Hsp.osm +1 -1
- data/data/geometry/DEER_Htl.osm +1 -1
- data/data/geometry/DEER_MBT.osm +1 -1
- data/data/geometry/DEER_MFm.osm +1 -1
- data/data/geometry/DEER_Nrs.osm +1 -1
- data/data/geometry/DEER_OfL.osm +1 -1
- data/data/geometry/DEER_OfS.osm +1 -1
- data/data/geometry/DEER_RFF.osm +1 -1
- data/data/geometry/DEER_RSD.osm +1 -1
- data/data/geometry/DEER_Rt3.osm +1 -1
- data/data/geometry/DEER_RtS.osm +1 -1
- data/data/standards/export_OpenStudio_libraries.rb +2 -3
- data/data/standards/test_performance_expected_dd_results.csv +42 -42
- data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
- data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
- data/lib/openstudio-standards/btap/activity.rb +480 -0
- data/lib/openstudio-standards/btap/attributes.rb +166 -0
- data/lib/openstudio-standards/btap/bridging.rb +561 -1402
- data/lib/openstudio-standards/btap/btap.rb +4 -2
- data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
- data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
- data/lib/openstudio-standards/btap/common_paths.rb +81 -0
- data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
- data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/materials_hvac.csv +1686 -0
- data/lib/openstudio-standards/btap/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +469 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +173 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +354 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +215 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +156 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +15 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +27 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/btap/geometry.rb +86 -6
- data/lib/openstudio-standards/btap/structure.rb +657 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
- data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
- data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
- data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
- data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
- data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
- data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
- data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
- data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
- data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
- data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
- data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
- data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
- data/lib/openstudio-standards/hvac/components/component.rb +39 -0
- data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
- data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
- data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
- data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
- data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
- data/lib/openstudio-standards/hvac/conversions.rb +222 -0
- data/lib/openstudio-standards/hvac/curves.rb +192 -0
- data/lib/openstudio-standards/hvac/helpers.rb +357 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
- data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
- data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
- data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
- data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
- data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
- data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
- data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
- data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
- data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
- data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
- data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
- data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
- data/lib/openstudio-standards/standards/Standards.Model.rb +45 -20
- data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
- data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +7 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
- data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
- data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +21 -37
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +115 -112
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +637 -249
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +75 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +25 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +18 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +68 -150
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +444 -134
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +17 -8
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +206 -32
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +75 -43
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
- data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards/weather/stat_file.rb +2 -2
- data/lib/openstudio-standards.rb +67 -38
- metadata +141 -50
- data/lib/openstudio-standards/hvac/components/create.rb +0 -169
- data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
- data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
|
@@ -211,13 +211,16 @@ module OpenstudioStandards
|
|
|
211
211
|
runperiodctrl_daylightsaving.setEndDate(end_date)
|
|
212
212
|
end
|
|
213
213
|
|
|
214
|
+
# set space type additional properties
|
|
215
|
+
standard.prototype_space_type_map(model, reset_standards_space_type: false, set_additional_properties: true)
|
|
216
|
+
|
|
214
217
|
# add internal loads to space types
|
|
215
218
|
if add_space_type_loads
|
|
216
219
|
|
|
217
220
|
# remove internal loads
|
|
218
221
|
if remove_objects
|
|
219
222
|
model.getSpaceLoads.sort.each do |instance|
|
|
220
|
-
# most prototype building types model
|
|
223
|
+
# most prototype building types model elevators with name Elevator
|
|
221
224
|
next if instance.name.to_s.include?('Elevator')
|
|
222
225
|
next if instance.to_InternalMass.is_initialized
|
|
223
226
|
next if instance.to_WaterUseEquipment.is_initialized
|
|
@@ -229,15 +232,17 @@ module OpenstudioStandards
|
|
|
229
232
|
end
|
|
230
233
|
|
|
231
234
|
model.getSpaceTypes.sort.each do |space_type|
|
|
232
|
-
|
|
235
|
+
# split out parts here to allow different options for lighting and ventilation
|
|
236
|
+
# lighting standard or technology
|
|
237
|
+
# ventilation standard
|
|
238
|
+
test = standard.space_type_apply_internal_loads(space_type)
|
|
233
239
|
if test == false
|
|
234
240
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Could not add loads for #{space_type.name}. Not expected for #{template}")
|
|
235
241
|
next
|
|
236
242
|
end
|
|
237
243
|
|
|
238
244
|
# apply internal load schedules
|
|
239
|
-
|
|
240
|
-
standard.space_type_apply_internal_load_schedules(space_type, true, true, true, true, true, false)
|
|
245
|
+
standard.space_type_apply_internal_load_schedules(space_type)
|
|
241
246
|
|
|
242
247
|
# extend space type name to include the template. Consider this as well for load defs
|
|
243
248
|
space_type.setName("#{space_type.name} - #{template}")
|
|
@@ -458,10 +463,10 @@ module OpenstudioStandards
|
|
|
458
463
|
ext_light.remove
|
|
459
464
|
end
|
|
460
465
|
end
|
|
461
|
-
exterior_lights = OpenstudioStandards::ExteriorLighting.
|
|
462
|
-
|
|
463
|
-
|
|
464
|
-
|
|
466
|
+
exterior_lights = OpenstudioStandards::ExteriorLighting.create_typical_exterior_lighting(model,
|
|
467
|
+
lighting_generation: 'default',
|
|
468
|
+
lighting_zone: exterior_lighting_zone.chars[0].to_i,
|
|
469
|
+
onsite_parking_fraction: onsite_parking_fraction)
|
|
465
470
|
exterior_lights.each do |v|
|
|
466
471
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Adding Exterior Lights named #{v.exteriorLightsDefinition.name} with design level of #{v.exteriorLightsDefinition.designLevel} * #{OpenStudio.toNeatString(v.multiplier, 0, true)}.")
|
|
467
472
|
end
|
|
@@ -578,28 +583,7 @@ module OpenstudioStandards
|
|
|
578
583
|
model.getThermostatSetpointDualSetpoints.each(&:remove)
|
|
579
584
|
end
|
|
580
585
|
|
|
581
|
-
model.
|
|
582
|
-
# create thermostat schedules
|
|
583
|
-
# skip un-recognized space types
|
|
584
|
-
next if standard.space_type_get_standards_data(space_type).empty?
|
|
585
|
-
|
|
586
|
-
# the last bool test it to make thermostat schedules. They are added to the model but not assigned
|
|
587
|
-
standard.space_type_apply_internal_load_schedules(space_type, false, false, false, false, false, true)
|
|
588
|
-
|
|
589
|
-
# identify thermal thermostat and apply to zones (apply_internal_load_schedules names )
|
|
590
|
-
model.getThermostatSetpointDualSetpoints.sort.each do |thermostat|
|
|
591
|
-
next if thermostat.name.to_s != "#{space_type.name} Thermostat"
|
|
592
|
-
next if !thermostat.coolingSetpointTemperatureSchedule.is_initialized
|
|
593
|
-
next if !thermostat.heatingSetpointTemperatureSchedule.is_initialized
|
|
594
|
-
|
|
595
|
-
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CreateTypical', "Assigning #{thermostat.name} to thermal zones with #{space_type.name} assigned.")
|
|
596
|
-
space_type.spaces.sort.each do |space|
|
|
597
|
-
next if !space.thermalZone.is_initialized
|
|
598
|
-
|
|
599
|
-
space.thermalZone.get.setThermostatSetpointDualSetpoint(thermostat)
|
|
600
|
-
end
|
|
601
|
-
end
|
|
602
|
-
end
|
|
586
|
+
OpenstudioStandards::ThermalZone.thermal_zones_set_thermostat_schedules(model.getThermalZones)
|
|
603
587
|
end
|
|
604
588
|
|
|
605
589
|
# add internal mass
|
|
@@ -933,13 +917,13 @@ module OpenstudioStandards
|
|
|
933
917
|
space_types_new << space_type
|
|
934
918
|
|
|
935
919
|
# add internal loads (the nil check isn't necessary, but I will keep it in as a warning instad of an error)
|
|
936
|
-
test = standard.space_type_apply_internal_loads(space_type
|
|
920
|
+
test = standard.space_type_apply_internal_loads(space_type)
|
|
937
921
|
if test.nil?
|
|
938
922
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CreateTypical', "Could not add loads for #{space_type.name}. Not expected for #{template} #{lookup_building_type}")
|
|
939
923
|
end
|
|
940
924
|
|
|
941
|
-
#
|
|
942
|
-
standard.space_type_apply_internal_load_schedules(space_type
|
|
925
|
+
# assign internal load schedules
|
|
926
|
+
standard.space_type_apply_internal_load_schedules(space_type)
|
|
943
927
|
|
|
944
928
|
# assign colors
|
|
945
929
|
standard.space_type_apply_rendering_color(space_type)
|
|
@@ -308,43 +308,43 @@ module OpenstudioStandards
|
|
|
308
308
|
when 'SmallDataCenterHighITE', 'SmallDataCenterLowITE'
|
|
309
309
|
hash['ComputerRoom'] = { ratio: 1.0, space_type_gen: true, default: true }
|
|
310
310
|
when 'Courthouse'
|
|
311
|
-
hash['
|
|
312
|
-
hash['
|
|
313
|
-
hash['
|
|
314
|
-
hash['
|
|
315
|
-
hash['
|
|
316
|
-
hash['
|
|
317
|
-
hash['
|
|
318
|
-
hash['
|
|
319
|
-
hash['
|
|
320
|
-
hash['
|
|
321
|
-
hash['
|
|
322
|
-
hash['
|
|
323
|
-
hash['
|
|
324
|
-
hash['
|
|
325
|
-
hash['
|
|
326
|
-
hash['
|
|
327
|
-
hash['
|
|
328
|
-
hash['
|
|
329
|
-
hash['
|
|
330
|
-
hash['
|
|
331
|
-
hash['
|
|
311
|
+
hash['Break Room'] = { ratio: 0.0067, space_type_gen: true, default: false }
|
|
312
|
+
hash['Cell'] = { ratio: 0.0731, space_type_gen: true, default: false }
|
|
313
|
+
hash['Conference'] = { ratio: 0.0203, space_type_gen: true, default: false }
|
|
314
|
+
hash['Corridor'] = { ratio: 0.0829, space_type_gen: true, default: false }
|
|
315
|
+
hash['Courtroom'] = { ratio: 0.1137, space_type_gen: true, default: false }
|
|
316
|
+
hash['Courtroom Waiting'] = { ratio: 0.051, space_type_gen: true, default: false }
|
|
317
|
+
hash['Elevator Lobby'] = { ratio: 0.0085, space_type_gen: true, default: false }
|
|
318
|
+
hash['Elevator Shaft'] = { ratio: 0.0047, space_type_gen: true, default: false }
|
|
319
|
+
hash['Entrance Lobby'] = { ratio: 0.0299, space_type_gen: true, default: false }
|
|
320
|
+
hash['Judges Chamber'] = { ratio: 0.0261, space_type_gen: true, default: false }
|
|
321
|
+
hash['Jury Assembly'] = { ratio: 0.0355, space_type_gen: true, default: false }
|
|
322
|
+
hash['Jury Deliberation'] = { ratio: 0.0133, space_type_gen: true, default: false }
|
|
323
|
+
hash['Library'] = { ratio: 0.0302, space_type_gen: true, default: false }
|
|
324
|
+
hash['Office'] = { ratio: 0.1930, space_type_gen: true, default: true }
|
|
325
|
+
hash['Parking'] = { ratio: 0.1083, space_type_gen: true, default: false }
|
|
326
|
+
hash['Restrooms'] = { ratio: 0.04, space_type_gen: true, default: false }
|
|
327
|
+
hash['Security Screening'] = { ratio: 0.0132, space_type_gen: true, default: false }
|
|
328
|
+
hash['Service Shaft'] = { ratio: 0.0019, space_type_gen: true, default: false }
|
|
329
|
+
hash['Stairs'] = { ratio: 0.0111, space_type_gen: true, default: false }
|
|
330
|
+
hash['Storage'] = { ratio: 0.0882, space_type_gen: true, default: false }
|
|
331
|
+
hash['Utility'] = { ratio: 0.0484, space_type_gen: true, default: false }
|
|
332
332
|
when 'College'
|
|
333
|
-
hash['
|
|
334
|
-
hash['
|
|
335
|
-
hash['
|
|
336
|
-
hash['
|
|
337
|
-
hash['
|
|
338
|
-
hash['
|
|
339
|
-
hash['
|
|
340
|
-
hash['
|
|
341
|
-
hash['
|
|
342
|
-
hash['
|
|
343
|
-
hash['
|
|
344
|
-
hash['
|
|
345
|
-
hash['
|
|
346
|
-
hash['
|
|
347
|
-
hash['
|
|
333
|
+
hash['Art Classroom'] = { ratio: 0.1868, space_type_gen: true, default: false }
|
|
334
|
+
hash['Classroom'] = { ratio: 0.2348, space_type_gen: true, default: true }
|
|
335
|
+
hash['Conference'] = { ratio: 0.0215, space_type_gen: true, default: false }
|
|
336
|
+
hash['Corridor'] = { ratio: 0.0716, space_type_gen: true, default: false }
|
|
337
|
+
hash['Elevator Shaft'] = { ratio: 0.0074, space_type_gen: true, default: false }
|
|
338
|
+
hash['Entrance Lobby'] = { ratio: 0.0117, space_type_gen: true, default: false }
|
|
339
|
+
hash['Laboratory'] = { ratio: 0.0843, space_type_gen: true, default: false }
|
|
340
|
+
hash['Lecture Hall'] = { ratio: 0.0421, space_type_gen: true, default: false }
|
|
341
|
+
hash['Lounge'] = { ratio: 0.028, space_type_gen: true, default: false }
|
|
342
|
+
hash['Media Center'] = { ratio: 0.0421, space_type_gen: true, default: false }
|
|
343
|
+
hash['Office'] = { ratio: 0.1894, space_type_gen: true, default: false }
|
|
344
|
+
hash['Restroom'] = { ratio: 0.0363, space_type_gen: true, default: false }
|
|
345
|
+
hash['Stairs'] = { ratio: 0.0272, space_type_gen: true, default: false }
|
|
346
|
+
hash['Storage'] = { ratio: 0.0117, space_type_gen: true, default: false }
|
|
347
|
+
hash['Utility'] = { ratio: 0.0051, space_type_gen: true, default: false }
|
|
348
348
|
|
|
349
349
|
# DEER Prototypes
|
|
350
350
|
when 'Asm'
|
|
@@ -0,0 +1,104 @@
|
|
|
1
|
+
module OpenstudioStandards
|
|
2
|
+
# The Equipment module provides methods to create, modify, and get information about equipment
|
|
3
|
+
module Equipment
|
|
4
|
+
# @!group Create Transformer
|
|
5
|
+
# Methods to create electrical transformers.
|
|
6
|
+
|
|
7
|
+
# Add transformer to the model
|
|
8
|
+
#
|
|
9
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
10
|
+
# @param name [String] the name of the transformer
|
|
11
|
+
# @param wired_lighting_frac [Double] the wired lighting fraction, 0-1
|
|
12
|
+
# @param transformer_size [Double] the transformer size in VA
|
|
13
|
+
# @param transformer_efficiency [Double] the transformer efficiency, 0-1
|
|
14
|
+
# @param excluded_interiorequip_key [String] key to exclude
|
|
15
|
+
# @param excluded_interiorequip_meter [String] meter to exclude
|
|
16
|
+
# @return [OpenStudio::Model::ElectricLoadCenterTransformer] the transformer object
|
|
17
|
+
def self.create_transformer(model,
|
|
18
|
+
name: 'Transformer_1',
|
|
19
|
+
wired_lighting_frac: nil,
|
|
20
|
+
transformer_size: nil,
|
|
21
|
+
transformer_efficiency: nil,
|
|
22
|
+
excluded_interiorequip_key: '',
|
|
23
|
+
excluded_interiorequip_meter: nil)
|
|
24
|
+
# throw an error if transformer properties are missing
|
|
25
|
+
if wired_lighting_frac.nil? || transformer_size.nil? || transformer_efficiency.nil?
|
|
26
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Equipment', "Either 'wired_lighting_frac', 'transformer_size', or 'transformer_efficiency' is unspecified. Cannot add transformer.")
|
|
27
|
+
return false
|
|
28
|
+
end
|
|
29
|
+
|
|
30
|
+
# throw an error if Decepticon
|
|
31
|
+
if ['megatron', 'starscream', 'soundwave', 'shockwave', 'skywarp', 'thundercracker', 'reflector'].include? name.downcase
|
|
32
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Equipment', "Decepticons will corrupt the OpenStudio model. Will not add transformer.")
|
|
33
|
+
return false
|
|
34
|
+
end
|
|
35
|
+
|
|
36
|
+
# @todo default values are for testing only
|
|
37
|
+
# ems sensor for interior lighting
|
|
38
|
+
facility_int_ltg = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'InteriorLights:Electricity')
|
|
39
|
+
facility_int_ltg.setName('Facility_Int_LTG')
|
|
40
|
+
|
|
41
|
+
# declaire ems variable for transformer wired lighting portion
|
|
42
|
+
wired_ltg_var = OpenStudio::Model::EnergyManagementSystemGlobalVariable.new(model, 'Wired_LTG')
|
|
43
|
+
|
|
44
|
+
# ems program for transformer load
|
|
45
|
+
transformer_load_prog = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
|
46
|
+
transformer_load_prog.setName('Transformer_Load_Prog')
|
|
47
|
+
transformer_load_prog_body = <<-EMS
|
|
48
|
+
SET Wired_LTG = Facility_Int_LTG*#{wired_lighting_frac}
|
|
49
|
+
EMS
|
|
50
|
+
transformer_load_prog.setBody(transformer_load_prog_body)
|
|
51
|
+
|
|
52
|
+
# ems program calling manager
|
|
53
|
+
transformer_load_prog_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
|
|
54
|
+
transformer_load_prog_manager.setName('Transformer_Load_Prog_Manager')
|
|
55
|
+
transformer_load_prog_manager.setCallingPoint('AfterPredictorAfterHVACManagers')
|
|
56
|
+
transformer_load_prog_manager.addProgram(transformer_load_prog)
|
|
57
|
+
|
|
58
|
+
# ems output variable
|
|
59
|
+
wired_ltg_emsout = OpenStudio::Model::EnergyManagementSystemOutputVariable.new(model, wired_ltg_var)
|
|
60
|
+
wired_ltg_emsout.setName('Wired_LTG')
|
|
61
|
+
wired_ltg_emsout.setTypeOfDataInVariable('Summed')
|
|
62
|
+
wired_ltg_emsout.setUpdateFrequency('ZoneTimeStep')
|
|
63
|
+
wired_ltg_emsout.setUnits('J')
|
|
64
|
+
|
|
65
|
+
# meter for ems output
|
|
66
|
+
wired_ltg_meter = OpenStudio::Model::MeterCustom.new(model)
|
|
67
|
+
wired_ltg_meter.setName('Wired_LTG_Electricity')
|
|
68
|
+
wired_ltg_meter.setFuelType('Electricity')
|
|
69
|
+
wired_ltg_meter.addKeyVarGroup('', 'Wired_LTG')
|
|
70
|
+
|
|
71
|
+
# meter for wired int equip
|
|
72
|
+
unless excluded_interiorequip_meter.nil?
|
|
73
|
+
wired_int_equip_meter = OpenStudio::Model::MeterCustomDecrement.new(model, 'InteriorEquipment:Electricity')
|
|
74
|
+
wired_int_equip_meter.setName('Wired_Int_EQUIP')
|
|
75
|
+
wired_int_equip_meter.setFuelType('Electricity')
|
|
76
|
+
wired_int_equip_meter.addKeyVarGroup(excluded_interiorequip_key, excluded_interiorequip_meter)
|
|
77
|
+
end
|
|
78
|
+
|
|
79
|
+
# add transformer
|
|
80
|
+
transformer = OpenStudio::Model::ElectricLoadCenterTransformer.new(model)
|
|
81
|
+
transformer.setName(name)
|
|
82
|
+
transformer.setAvailabilitySchedule(model.alwaysOnDiscreteSchedule)
|
|
83
|
+
transformer.setTransformerUsage('PowerInFromGrid')
|
|
84
|
+
transformer.setRatedCapacity(transformer_size)
|
|
85
|
+
transformer.setPhase('3')
|
|
86
|
+
transformer.setConductorMaterial('Aluminum')
|
|
87
|
+
transformer.setFullLoadTemperatureRise(150)
|
|
88
|
+
transformer.setFractionofEddyCurrentLosses(0.1)
|
|
89
|
+
transformer.setPerformanceInputMethod('NominalEfficiency')
|
|
90
|
+
transformer.setNameplateEfficiency(transformer_efficiency)
|
|
91
|
+
transformer.setPerUnitLoadforNameplateEfficiency(0.35)
|
|
92
|
+
transformer.setReferenceTemperatureforNameplateEfficiency(75)
|
|
93
|
+
transformer.setConsiderTransformerLossforUtilityCost(true)
|
|
94
|
+
transformer.addMeter('Wired_LTG_Electricity')
|
|
95
|
+
if excluded_interiorequip_meter.nil?
|
|
96
|
+
transformer.addMeter('InteriorEquipment:Electricity') # by default, add this as the second meter
|
|
97
|
+
else
|
|
98
|
+
transformer.addMeter('Wired_Int_EQUIP')
|
|
99
|
+
end
|
|
100
|
+
|
|
101
|
+
return transformer
|
|
102
|
+
end
|
|
103
|
+
end
|
|
104
|
+
end
|
|
@@ -0,0 +1,117 @@
|
|
|
1
|
+
module OpenstudioStandards
|
|
2
|
+
# The Equipment module provides methods to create, modify, and get information about equipment
|
|
3
|
+
module Equipment
|
|
4
|
+
# @!group Create Typical Equipment
|
|
5
|
+
# Methods to create typical equipment
|
|
6
|
+
|
|
7
|
+
# Create typical equipment in a model
|
|
8
|
+
#
|
|
9
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
10
|
+
# @return [Boolean] returns true if successful, false if not
|
|
11
|
+
def self.create_typical_equipment(model)
|
|
12
|
+
# load equipment data
|
|
13
|
+
electric_equipment_space_type_data = JSON.parse(File.read("#{File.dirname(__FILE__)}/data/electric_equipment_space_types.json"), symbolize_names: true)
|
|
14
|
+
gas_equipment_space_type_data = JSON.parse(File.read("#{File.dirname(__FILE__)}/data/gas_equipment_space_types.json"), symbolize_names: true)
|
|
15
|
+
|
|
16
|
+
if electric_equipment_space_type_data.nil? || gas_equipment_space_type_data.nil?
|
|
17
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Equipment', 'Unable to load equipment space types data. No equipment will be added to model.')
|
|
18
|
+
return false
|
|
19
|
+
end
|
|
20
|
+
|
|
21
|
+
# loop over space types and apply equipment
|
|
22
|
+
model.getSpaceTypes.each do |space_type|
|
|
23
|
+
# remove existing equipment objects
|
|
24
|
+
space_type.electricEquipment.sort.each(&:remove)
|
|
25
|
+
space_type.gasEquipment.sort.each(&:remove)
|
|
26
|
+
|
|
27
|
+
# remove existing equipment objects from spaces
|
|
28
|
+
space_type.spaces.each do |space|
|
|
29
|
+
space.electricEquipment.sort.each(&:remove)
|
|
30
|
+
space.gasEquipment.sort.each(&:remove)
|
|
31
|
+
end
|
|
32
|
+
|
|
33
|
+
# get building type
|
|
34
|
+
standards_building_type = nil
|
|
35
|
+
if space_type.standardsBuildingType.is_initialized
|
|
36
|
+
standards_building_type = space_type.standardsBuildingType.get
|
|
37
|
+
end
|
|
38
|
+
|
|
39
|
+
# get equipment space type from the object
|
|
40
|
+
has_electric_equipment_space_type = space_type.additionalProperties.hasFeature('electric_equipment_space_type')
|
|
41
|
+
has_gas_equipment_space_type = space_type.additionalProperties.hasFeature('natural_gas_equipment_space_type')
|
|
42
|
+
unless has_electric_equipment_space_type || has_gas_equipment_space_type
|
|
43
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Equipment', "Space type '#{space_type.name}' does not have a electric_equipment_space_type or natural_gas_equipment_space_type property assigned. Ignoring space type.")
|
|
44
|
+
next
|
|
45
|
+
end
|
|
46
|
+
if has_electric_equipment_space_type
|
|
47
|
+
electric_equipment_space_type = space_type.additionalProperties.getFeatureAsString('electric_equipment_space_type').to_s
|
|
48
|
+
else
|
|
49
|
+
electric_equipment_space_type = nil
|
|
50
|
+
end
|
|
51
|
+
if has_gas_equipment_space_type
|
|
52
|
+
gas_equipment_space_type = space_type.additionalProperties.getFeatureAsString('natural_gas_equipment_space_type').to_s
|
|
53
|
+
else
|
|
54
|
+
gas_equipment_space_type = nil
|
|
55
|
+
end
|
|
56
|
+
|
|
57
|
+
if has_electric_equipment_space_type && !electric_equipment_space_type.nil? && (electric_equipment_space_type != 'na')
|
|
58
|
+
# get equipment properties for the electric equipment space type
|
|
59
|
+
electric_equipment_space_type_properties = electric_equipment_space_type_data.select { |r| (r[:electric_equipment_space_type_name] == electric_equipment_space_type) && (r[:standards_building_type] == standards_building_type) }
|
|
60
|
+
if electric_equipment_space_type_properties.empty?
|
|
61
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Equipment', "Unable to find electric equipment space type data for '#{electric_equipment_space_type}' with standards_building_type #{standards_building_type}.")
|
|
62
|
+
else
|
|
63
|
+
electric_equipment_space_type_properties = electric_equipment_space_type_properties[0]
|
|
64
|
+
elec_equip_per_area = electric_equipment_space_type_properties[:electric_equipment_per_area].to_f
|
|
65
|
+
elec_equip_frac_latent = electric_equipment_space_type_properties[:electric_equipment_fraction_latent]
|
|
66
|
+
elec_equip_frac_radiant = electric_equipment_space_type_properties[:electric_equipment_fraction_radiant]
|
|
67
|
+
elec_equip_frac_lost = electric_equipment_space_type_properties[:electric_equipment_fraction_lost]
|
|
68
|
+
if elec_equip_per_area > 0
|
|
69
|
+
definition = OpenStudio::Model::ElectricEquipmentDefinition.new(space_type.model)
|
|
70
|
+
definition.setName("#{space_type.name} Elec Equip Definition")
|
|
71
|
+
definition.setWattsperSpaceFloorArea(OpenStudio.convert(elec_equip_per_area.to_f, 'W/ft^2', 'W/m^2').get)
|
|
72
|
+
definition.resetFractionLatent unless definition.isFractionLatentDefaulted
|
|
73
|
+
definition.resetFractionRadiant unless definition.isFractionRadiantDefaulted
|
|
74
|
+
definition.resetFractionLost unless definition.isFractionLostDefaulted
|
|
75
|
+
definition.setFractionLatent(elec_equip_frac_latent.to_f) if elec_equip_frac_latent
|
|
76
|
+
definition.setFractionRadiant(elec_equip_frac_radiant.to_f) if elec_equip_frac_radiant
|
|
77
|
+
definition.setFractionLost(elec_equip_frac_lost.to_f) if elec_equip_frac_lost
|
|
78
|
+
instance = OpenStudio::Model::ElectricEquipment.new(definition)
|
|
79
|
+
instance.setName("#{space_type.name} Elec Equip")
|
|
80
|
+
instance.setSpaceType(space_type)
|
|
81
|
+
end
|
|
82
|
+
end
|
|
83
|
+
end
|
|
84
|
+
|
|
85
|
+
if has_gas_equipment_space_type && !gas_equipment_space_type.nil? && (gas_equipment_space_type != 'na')
|
|
86
|
+
# get equipment properties for the gas equipment space type
|
|
87
|
+
gas_equipment_space_type_properties = gas_equipment_space_type_data.select { |r| (r[:natural_gas_equipment_space_type_name] == gas_equipment_space_type) && (r[:standards_building_type] == standards_building_type) }
|
|
88
|
+
if gas_equipment_space_type_properties.empty?
|
|
89
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.Equipment', "Unable to find gas equipment space type data for '#{gas_equipment_space_type}' with standards_building_type #{standards_building_type}.")
|
|
90
|
+
else
|
|
91
|
+
gas_equipment_space_type_properties = gas_equipment_space_type_properties[0]
|
|
92
|
+
gas_equip_per_area = gas_equipment_space_type_properties[:gas_equipment_per_area].to_f
|
|
93
|
+
gas_equip_frac_latent = gas_equipment_space_type_properties[:gas_equipment_fraction_latent]
|
|
94
|
+
gas_equip_frac_radiant = gas_equipment_space_type_properties[:gas_equipment_fraction_radiant]
|
|
95
|
+
gas_equip_frac_lost = gas_equipment_space_type_properties[:gas_equipment_fraction_lost]
|
|
96
|
+
if gas_equip_per_area > 0
|
|
97
|
+
definition = OpenStudio::Model::GasEquipmentDefinition.new(space_type.model)
|
|
98
|
+
definition.setName("#{space_type.name} Gas Equip Definition")
|
|
99
|
+
definition.setWattsperSpaceFloorArea(OpenStudio.convert(gas_equip_per_area.to_f, 'Btu/hr*ft^2', 'W/m^2').get)
|
|
100
|
+
definition.resetFractionLatent unless definition.isFractionLatentDefaulted
|
|
101
|
+
definition.resetFractionRadiant unless definition.isFractionRadiantDefaulted
|
|
102
|
+
definition.resetFractionLost unless definition.isFractionLostDefaulted
|
|
103
|
+
definition.setFractionLatent(gas_equip_frac_latent.to_f) if gas_equip_frac_latent
|
|
104
|
+
definition.setFractionRadiant(gas_equip_frac_radiant.to_f) if gas_equip_frac_radiant
|
|
105
|
+
definition.setFractionLost(gas_equip_frac_lost.to_f) if gas_equip_frac_lost
|
|
106
|
+
instance = OpenStudio::Model::GasEquipment.new(definition)
|
|
107
|
+
instance.setName("#{space_type.name} Gas Equip")
|
|
108
|
+
instance.setSpaceType(space_type)
|
|
109
|
+
end
|
|
110
|
+
end
|
|
111
|
+
end
|
|
112
|
+
end
|
|
113
|
+
|
|
114
|
+
return true
|
|
115
|
+
end
|
|
116
|
+
end
|
|
117
|
+
end
|