openstudio-standards 0.8.3 → 0.8.5.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (330) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.osm +30 -30
  3. data/data/geometry/ASHRAECourthouse.osm +22 -22
  4. data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
  5. data/data/geometry/DEER_Asm.osm +1 -1
  6. data/data/geometry/DEER_ECC.osm +1 -1
  7. data/data/geometry/DEER_EPr.osm +1 -1
  8. data/data/geometry/DEER_ERC.osm +1 -1
  9. data/data/geometry/DEER_ESe.osm +1 -1
  10. data/data/geometry/DEER_EUn.osm +1 -1
  11. data/data/geometry/DEER_Hsp.osm +1 -1
  12. data/data/geometry/DEER_Htl.osm +1 -1
  13. data/data/geometry/DEER_MBT.osm +1 -1
  14. data/data/geometry/DEER_MFm.osm +1 -1
  15. data/data/geometry/DEER_Nrs.osm +1 -1
  16. data/data/geometry/DEER_OfL.osm +1 -1
  17. data/data/geometry/DEER_OfS.osm +1 -1
  18. data/data/geometry/DEER_RFF.osm +1 -1
  19. data/data/geometry/DEER_RSD.osm +1 -1
  20. data/data/geometry/DEER_Rt3.osm +1 -1
  21. data/data/geometry/DEER_RtS.osm +1 -1
  22. data/data/standards/export_OpenStudio_libraries.rb +2 -3
  23. data/data/standards/test_performance_expected_dd_results.csv +42 -42
  24. data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
  25. data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
  26. data/lib/openstudio-standards/btap/activity.rb +480 -0
  27. data/lib/openstudio-standards/btap/attributes.rb +166 -0
  28. data/lib/openstudio-standards/btap/bridging.rb +561 -1402
  29. data/lib/openstudio-standards/btap/btap.rb +4 -2
  30. data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
  31. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
  32. data/lib/openstudio-standards/btap/common_paths.rb +81 -0
  33. data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +52 -0
  34. data/lib/openstudio-standards/btap/common_resources/Constructions.csv +37 -0
  35. data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
  36. data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
  37. data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
  38. data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +1270 -0
  39. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
  40. data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +2256 -0
  41. data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
  42. data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +2315 -0
  43. data/lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv +925 -0
  44. data/lib/openstudio-standards/btap/common_resources/lighting.csv +364 -0
  45. data/lib/openstudio-standards/btap/common_resources/lighting_sets.csv +2667 -0
  46. data/lib/openstudio-standards/btap/common_resources/locations.csv +75 -0
  47. data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +35 -0
  48. data/lib/openstudio-standards/btap/common_resources/materials_hvac.csv +1686 -0
  49. data/lib/openstudio-standards/btap/common_resources/materials_lighting.csv +267 -0
  50. data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +164 -0
  51. data/lib/openstudio-standards/btap/costing/README.md +502 -0
  52. data/lib/openstudio-standards/btap/costing/btap_costing.rb +469 -0
  53. data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
  54. data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
  55. data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
  56. data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
  57. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +173 -0
  58. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +354 -0
  59. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
  60. data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
  61. data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
  62. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +215 -0
  63. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
  64. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +156 -0
  65. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
  66. data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
  67. data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
  68. data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
  69. data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
  70. data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
  71. data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
  72. data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
  73. data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
  74. data/lib/openstudio-standards/btap/costing/test_list.txt +15 -0
  75. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +27 -0
  76. data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
  77. data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
  78. data/lib/openstudio-standards/btap/geometry.rb +86 -6
  79. data/lib/openstudio-standards/btap/structure.rb +657 -0
  80. data/lib/openstudio-standards/constructions/modify.rb +2 -1
  81. data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
  82. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
  83. data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
  84. data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
  85. data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
  86. data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
  87. data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
  88. data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
  89. data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
  90. data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
  91. data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
  92. data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
  93. data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
  94. data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
  95. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
  96. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
  97. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
  98. data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
  99. data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
  100. data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
  101. data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
  102. data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
  103. data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
  104. data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
  105. data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
  106. data/lib/openstudio-standards/hvac/components/component.rb +39 -0
  107. data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
  108. data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
  109. data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
  110. data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
  111. data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
  112. data/lib/openstudio-standards/hvac/conversions.rb +222 -0
  113. data/lib/openstudio-standards/hvac/curves.rb +192 -0
  114. data/lib/openstudio-standards/hvac/helpers.rb +357 -0
  115. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
  116. data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
  117. data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
  118. data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
  119. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
  120. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
  121. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
  122. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
  123. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  124. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  125. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  126. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
  127. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  128. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
  129. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  130. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  131. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
  132. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
  133. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
  134. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
  135. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
  136. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
  137. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
  138. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
  139. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
  140. data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
  141. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
  142. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
  143. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
  144. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
  145. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
  146. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
  147. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
  148. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
  149. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
  150. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
  151. data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
  152. data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
  153. data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
  154. data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
  155. data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
  156. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
  157. data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
  158. data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
  159. data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
  160. data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
  161. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
  162. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
  163. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
  164. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
  165. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
  166. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
  167. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
  168. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
  169. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
  170. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
  171. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
  172. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
  173. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
  174. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
  175. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
  176. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
  177. data/lib/openstudio-standards/standards/Standards.Model.rb +45 -20
  178. data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
  179. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
  180. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
  181. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
  182. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
  183. data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
  184. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
  185. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
  186. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
  187. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
  188. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
  189. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
  191. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  192. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
  193. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
  194. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
  195. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  196. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
  197. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
  198. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
  199. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
  200. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
  202. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
  203. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
  204. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
  205. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
  206. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  207. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
  208. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
  209. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
  210. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
  211. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
  212. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
  213. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
  214. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
  215. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
  216. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
  217. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  218. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
  219. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  220. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
  221. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
  222. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
  223. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
  224. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
  225. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
  226. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
  227. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
  228. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
  229. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
  230. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
  231. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
  232. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
  233. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
  234. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
  235. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +7 -1
  236. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
  237. data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
  238. data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
  239. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +21 -37
  240. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
  241. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
  242. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
  243. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
  244. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
  245. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
  246. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +115 -112
  247. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +637 -249
  248. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
  249. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
  250. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
  251. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +75 -7
  252. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +25 -1
  253. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
  254. data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
  255. data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
  256. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
  257. data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
  258. data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
  259. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
  260. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +18 -6
  261. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
  262. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
  263. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
  264. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
  265. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
  266. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +68 -150
  267. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +444 -134
  268. data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
  269. data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
  270. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
  271. data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
  272. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +17 -8
  273. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
  274. data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
  275. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
  276. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
  277. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
  278. data/lib/openstudio-standards/standards/necb/README.md +343 -0
  279. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
  280. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +206 -32
  281. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +75 -43
  282. data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
  283. data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
  284. data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
  285. data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
  286. data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
  287. data/lib/openstudio-standards/utilities/logging.rb +18 -14
  288. data/lib/openstudio-standards/version.rb +1 -1
  289. data/lib/openstudio-standards/weather/modify.rb +2 -2
  290. data/lib/openstudio-standards/weather/stat_file.rb +2 -2
  291. data/lib/openstudio-standards.rb +67 -38
  292. metadata +141 -50
  293. data/lib/openstudio-standards/hvac/components/create.rb +0 -169
  294. data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
  295. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
  296. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
  297. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
  298. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
  299. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
  300. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
  301. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
  302. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
  303. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
  304. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
  305. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
  306. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
  307. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
  308. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
  309. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
  310. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
  311. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
  312. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
  313. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
  314. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
  315. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
  316. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
  317. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
  318. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
  319. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
  320. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
  321. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
  322. data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
  323. data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
  324. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
  325. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
  326. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
  327. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
  328. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
  329. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
  330. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
@@ -22,10 +22,18 @@ module OpenstudioStandards
22
22
  require_relative 'openstudio-standards/constructions/materials/information'
23
23
  require_relative 'openstudio-standards/constructions/materials/modify'
24
24
 
25
+ # Equipment Module
26
+ require_relative 'openstudio-standards/equipment/create_typical_equipment'
27
+ require_relative 'openstudio-standards/equipment/create_transformer'
28
+
25
29
  # Infiltration Module
26
30
  require_relative 'openstudio-standards/infiltration/infiltration'
27
31
  require_relative 'openstudio-standards/infiltration/nist_infiltration'
28
32
 
33
+ # Interior Lighting Module
34
+ require_relative 'openstudio-standards/interior_lighting/create_lights'
35
+ require_relative 'openstudio-standards/interior_lighting/create_typical_interior_lighting'
36
+
29
37
  # Daylighting Module
30
38
  require_relative 'openstudio-standards/daylighting/space'
31
39
 
@@ -59,16 +67,43 @@ module OpenstudioStandards
59
67
  # Space Module
60
68
  require_relative 'openstudio-standards/space/space'
61
69
 
70
+ # Space Type Module
71
+ require_relative 'openstudio-standards/space_type/standards_space_type'
72
+
62
73
  # Thermal Zone Module
63
- require_relative 'openstudio-standards/thermal_zone/thermal_zone'
74
+ require_relative 'openstudio-standards/thermal_zone/information'
75
+ require_relative 'openstudio-standards/thermal_zone/thermostat_schedules'
64
76
 
65
77
  # HVAC Module
66
78
  require_relative 'openstudio-standards/hvac/air_loop/information'
79
+ require_relative 'openstudio-standards/hvac/cbecs_hvac'
80
+ require_relative 'openstudio-standards/hvac/curves'
81
+ require_relative 'openstudio-standards/hvac/components/air_conditioner_vrf'
82
+ require_relative 'openstudio-standards/hvac/components/air_terminal'
83
+ require_relative 'openstudio-standards/hvac/components/boiler_hot_water'
84
+ require_relative 'openstudio-standards/hvac/components/central_air_source_heat_pump'
85
+ require_relative 'openstudio-standards/hvac/components/chiller'
86
+ require_relative 'openstudio-standards/hvac/components/coil'
87
+ require_relative 'openstudio-standards/hvac/components/coil_cooling_dx_single_speed'
88
+ require_relative 'openstudio-standards/hvac/components/coil_cooling_dx_two_speed'
89
+ require_relative 'openstudio-standards/hvac/components/coil_cooling_dx_multi_speed'
90
+ require_relative 'openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit'
91
+ require_relative 'openstudio-standards/hvac/components/coil_cooling_water'
92
+ require_relative 'openstudio-standards/hvac/components/coil_heating_dx_single_speed'
93
+ require_relative 'openstudio-standards/hvac/components/coil_heating_electric'
94
+ require_relative 'openstudio-standards/hvac/components/coil_heating_gas'
95
+ require_relative 'openstudio-standards/hvac/components/coil_heating_gas_multi_stage'
96
+ require_relative 'openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit'
97
+ require_relative 'openstudio-standards/hvac/components/coil_heating_water'
98
+ require_relative 'openstudio-standards/hvac/components/component'
99
+ require_relative 'openstudio-standards/hvac/components/fan'
100
+ require_relative 'openstudio-standards/hvac/components/heat_exchanger_air_to_air'
101
+ require_relative 'openstudio-standards/hvac/components/pump'
102
+ require_relative 'openstudio-standards/hvac/controls/radiant_system_controls'
103
+ require_relative 'openstudio-standards/hvac/conversions'
104
+ require_relative 'openstudio-standards/hvac/helpers'
67
105
  require_relative 'openstudio-standards/hvac/exhaust/create_exhaust_fan'
68
106
  require_relative 'openstudio-standards/hvac/setpoint_managers/information'
69
- require_relative 'openstudio-standards/hvac/cbecs_hvac'
70
- require_relative 'openstudio-standards/hvac/components/create'
71
- require_relative 'openstudio-standards/hvac/components/modify'
72
107
 
73
108
  # CreateTypical Module
74
109
  require_relative 'openstudio-standards/create_typical/enumerations'
@@ -106,6 +141,19 @@ module OpenstudioStandards
106
141
 
107
142
  # BTAP (Natural Resources Canada)
108
143
  require_relative 'openstudio-standards/btap/btap'
144
+ require_relative 'openstudio-standards/btap/common_paths'
145
+ require_relative 'openstudio-standards/btap/costing/btap_costing'
146
+ require_relative 'openstudio-standards/btap/carbon/btap_carbon'
147
+ require_relative 'openstudio-standards/btap/costing/ventilation_costing'
148
+ require_relative 'openstudio-standards/btap/costing/envelope_costing'
149
+ require_relative 'openstudio-standards/btap/costing/lighting_costing'
150
+ require_relative 'openstudio-standards/btap/costing/heating_cooling_costing'
151
+ require_relative 'openstudio-standards/btap/costing/shw_costing'
152
+ require_relative 'openstudio-standards/btap/costing/dcv_costing'
153
+ require_relative 'openstudio-standards/btap/costing/daylighting_sensor_control_costing'
154
+ require_relative 'openstudio-standards/btap/costing/led_lighting_costing'
155
+ require_relative 'openstudio-standards/btap/costing/pv_ground_costing'
156
+ require_relative 'openstudio-standards/btap/costing/nv_costing'
109
157
 
110
158
  # Utilities
111
159
  require_relative 'openstudio-standards/utilities/logging'
@@ -137,6 +185,7 @@ module OpenstudioStandards
137
185
  require_relative "#{stds}/necb/NECB2011/hvac_system_3_and_8_multi_speed"
138
186
  require_relative "#{stds}/necb/NECB2011/hvac_system_4"
139
187
  require_relative "#{stds}/necb/NECB2011/hvac_system_6"
188
+ require_relative "#{stds}/necb/NECB2011/hvac_namer"
140
189
  require_relative "#{stds}/necb/NECB2011/service_water_heating"
141
190
  require_relative "#{stds}/necb/NECB2011/electrical_power_systems_and_motors"
142
191
  require_relative "#{stds}/necb/NECB2011/beps_compliance_path"
@@ -166,6 +215,7 @@ module OpenstudioStandards
166
215
  # NECB QAQC
167
216
  require_relative "#{stds}/necb/NECB2011/qaqc/necb_qaqc.rb"
168
217
  require_relative "#{stds}/necb/NECB2015/qaqc/necb_2015_qaqc.rb"
218
+ require_relative "#{stds}/necb/common/btap_analysis.rb"
169
219
  require_relative "#{stds}/necb/common/btap_data.rb"
170
220
  require_relative "#{stds}/necb/common/btap_datapoint.rb"
171
221
 
@@ -281,19 +331,15 @@ module OpenstudioStandards
281
331
  require_relative "#{stds}/Standards.CoolingTowerSingleSpeed"
282
332
  require_relative "#{stds}/Standards.CoolingTowerTwoSpeed"
283
333
  require_relative "#{stds}/Standards.CoolingTowerVariableSpeed"
284
- require_relative "#{stds}/Standards.FanConstantVolume"
285
- require_relative "#{stds}/Standards.FanOnOff"
286
334
  require_relative "#{stds}/Standards.FanVariableVolume"
287
- require_relative "#{stds}/Standards.FanZoneExhaust"
288
335
  require_relative "#{stds}/Standards.FluidCooler"
289
- require_relative "#{stds}/Standards.HeaderedPumpsConstantSpeed"
290
- require_relative "#{stds}/Standards.HeaderedPumpsVariableSpeed"
291
336
  require_relative "#{stds}/Standards.HeatExchangerSensLat"
292
337
  require_relative "#{stds}/Standards.Model"
293
338
  require_relative "#{stds}/Standards.Motor"
339
+ require_relative "#{stds}/Standards.People"
294
340
  require_relative "#{stds}/Standards.PlanarSurface"
295
341
  require_relative "#{stds}/Standards.PlantLoop"
296
- require_relative "#{stds}/Standards.PumpConstantSpeed"
342
+ require_relative "#{stds}/Standards.Pump"
297
343
  require_relative "#{stds}/Standards.PumpVariableSpeed"
298
344
  require_relative "#{stds}/Standards.ScheduleRuleset"
299
345
  require_relative "#{stds}/Standards.ServiceWaterHeating"
@@ -302,6 +348,7 @@ module OpenstudioStandards
302
348
  require_relative "#{stds}/Standards.SubSurface"
303
349
  require_relative "#{stds}/Standards.Surface"
304
350
  require_relative "#{stds}/Standards.ThermalZone"
351
+ require_relative "#{stds}/Standards.Ventilation"
305
352
  require_relative "#{stds}/Standards.WaterHeaterMixed"
306
353
  require_relative "#{stds}/Standards.ZoneHVACComponent"
307
354
  # 90.1 Common
@@ -312,6 +359,7 @@ module OpenstudioStandards
312
359
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume"
313
360
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Model"
314
361
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop"
362
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed"
315
363
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.ThermalZone"
316
364
  # 90.1-2007
317
365
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC"
@@ -319,6 +367,7 @@ module OpenstudioStandards
319
367
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.ChillerElectricEIR"
320
368
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume"
321
369
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model"
370
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed"
322
371
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.ThermalZone"
323
372
  # 90.1-2010
324
373
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC"
@@ -331,6 +380,7 @@ module OpenstudioStandards
331
380
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTowerVariableSpeed"
332
381
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume"
333
382
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model"
383
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed"
334
384
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space"
335
385
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.ThermalZone"
336
386
  # 90.1-2013
@@ -346,6 +396,7 @@ module OpenstudioStandards
346
396
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model"
347
397
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Motor"
348
398
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PlantLoop"
399
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed"
349
400
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space"
350
401
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone"
351
402
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed"
@@ -361,6 +412,7 @@ module OpenstudioStandards
361
412
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume"
362
413
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model"
363
414
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Motor"
415
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed"
364
416
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space"
365
417
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone"
366
418
  # 90.1-2019
@@ -376,6 +428,8 @@ module OpenstudioStandards
376
428
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume"
377
429
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model"
378
430
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Motor"
431
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump"
432
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed"
379
433
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space"
380
434
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone"
381
435
  require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.WaterHeaterMixed"
@@ -388,10 +442,7 @@ module OpenstudioStandards
388
442
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat"
389
443
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent"
390
444
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop"
391
- require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume"
392
- require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff"
393
445
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume"
394
- require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust"
395
446
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX"
396
447
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed"
397
448
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed"
@@ -479,6 +530,9 @@ module OpenstudioStandards
479
530
  require_relative "#{stds}/cbes/cbes.PlantLoop"
480
531
 
481
532
  ### Prototypes ###
533
+ # Mapping Old Standards Space Types
534
+ require_relative "#{proto}/common/prototype_space_type_map"
535
+
482
536
  # Building Types
483
537
  require_relative "#{proto}/common/buildings/Prototype.FullServiceRestaurant"
484
538
  require_relative "#{proto}/common/buildings/Prototype.HighRiseApartment"
@@ -515,22 +569,8 @@ module OpenstudioStandards
515
569
  create_meta_classes
516
570
 
517
571
  # Model Objects
518
- require_relative "#{proto}/common/objects/Prototype.AirConditionerVariableRefrigerantFlow"
519
572
  require_relative "#{proto}/common/objects/Prototype.AirTerminalSingleDuctVAVReheat"
520
- require_relative "#{proto}/common/objects/Prototype.BoilerHotWater"
521
- require_relative "#{proto}/common/objects/Prototype.CentralAirSourceHeatPump"
522
- require_relative "#{proto}/common/objects/Prototype.CoilCoolingDXSingleSpeed"
523
- require_relative "#{proto}/common/objects/Prototype.CoilCoolingDXTwoSpeed"
524
- require_relative "#{proto}/common/objects/Prototype.CoilCoolingWater"
525
- require_relative "#{proto}/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit"
526
- require_relative "#{proto}/common/objects/Prototype.CoilHeatingDXSingleSpeed"
527
- require_relative "#{proto}/common/objects/Prototype.CoilHeatingElectric"
528
- require_relative "#{proto}/common/objects/Prototype.CoilHeatingGas"
529
- require_relative "#{proto}/common/objects/Prototype.CoilHeatingWater"
530
- require_relative "#{proto}/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit"
531
- require_relative "#{proto}/common/objects/Prototype.ControllerWaterCoil"
532
573
  require_relative "#{proto}/common/objects/Prototype.CoolingTower"
533
- require_relative "#{proto}/common/objects/Prototype.radiant_system_controls"
534
574
  require_relative "#{proto}/common/objects/Prototype.Fan"
535
575
  require_relative "#{proto}/common/objects/Prototype.FanConstantVolume"
536
576
  require_relative "#{proto}/common/objects/Prototype.FanOnOff"
@@ -539,23 +579,17 @@ module OpenstudioStandards
539
579
  require_relative "#{proto}/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent"
540
580
  require_relative "#{proto}/common/objects/Prototype.hvac_systems"
541
581
  require_relative "#{proto}/common/objects/Prototype.Model.elevators"
542
- require_relative "#{proto}/common/objects/Prototype.Model.transformers"
543
582
  require_relative "#{proto}/common/objects/Prototype.Model.hvac"
544
583
  require_relative "#{proto}/common/objects/Prototype.Model"
545
- require_relative "#{proto}/common/objects/Prototype.Pump"
546
- require_relative "#{proto}/common/objects/Prototype.PumpVariableSpeed"
547
584
  require_relative "#{proto}/common/objects/Prototype.refrigeration"
548
585
  require_relative "#{proto}/common/objects/Prototype.SizingSystem"
549
- require_relative "#{proto}/common/objects/Prototype.utilities"
550
586
  # 90.1-2004
551
587
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat"
552
- require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed"
553
588
  # 90.1-2007
554
589
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume"
555
590
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff"
556
591
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume"
557
592
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat"
558
- require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed"
559
593
  # 90.1-2010
560
594
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume"
561
595
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff"
@@ -563,7 +597,6 @@ module OpenstudioStandards
563
597
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model"
564
598
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators"
565
599
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat"
566
- require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed"
567
600
  # 90.1-2013
568
601
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume"
569
602
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff"
@@ -572,7 +605,6 @@ module OpenstudioStandards
572
605
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators"
573
606
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems"
574
607
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat"
575
- require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed"
576
608
  # 90.1-2016
577
609
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume"
578
610
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff"
@@ -581,7 +613,6 @@ module OpenstudioStandards
581
613
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators"
582
614
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems"
583
615
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat"
584
- require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed"
585
616
  # 90.1-2019
586
617
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume"
587
618
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff"
@@ -590,8 +621,6 @@ module OpenstudioStandards
590
621
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators"
591
622
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems"
592
623
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat"
593
- require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump"
594
- require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed"
595
624
  require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space"
596
625
  # DOE Ref 1980-2004
597
626
  require_relative "#{proto}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat"