openstudio-standards 0.8.3 → 0.8.5.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.osm +30 -30
- data/data/geometry/ASHRAECourthouse.osm +22 -22
- data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
- data/data/geometry/DEER_Asm.osm +1 -1
- data/data/geometry/DEER_ECC.osm +1 -1
- data/data/geometry/DEER_EPr.osm +1 -1
- data/data/geometry/DEER_ERC.osm +1 -1
- data/data/geometry/DEER_ESe.osm +1 -1
- data/data/geometry/DEER_EUn.osm +1 -1
- data/data/geometry/DEER_Hsp.osm +1 -1
- data/data/geometry/DEER_Htl.osm +1 -1
- data/data/geometry/DEER_MBT.osm +1 -1
- data/data/geometry/DEER_MFm.osm +1 -1
- data/data/geometry/DEER_Nrs.osm +1 -1
- data/data/geometry/DEER_OfL.osm +1 -1
- data/data/geometry/DEER_OfS.osm +1 -1
- data/data/geometry/DEER_RFF.osm +1 -1
- data/data/geometry/DEER_RSD.osm +1 -1
- data/data/geometry/DEER_Rt3.osm +1 -1
- data/data/geometry/DEER_RtS.osm +1 -1
- data/data/standards/export_OpenStudio_libraries.rb +2 -3
- data/data/standards/test_performance_expected_dd_results.csv +42 -42
- data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
- data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
- data/lib/openstudio-standards/btap/activity.rb +480 -0
- data/lib/openstudio-standards/btap/attributes.rb +166 -0
- data/lib/openstudio-standards/btap/bridging.rb +561 -1402
- data/lib/openstudio-standards/btap/btap.rb +4 -2
- data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
- data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
- data/lib/openstudio-standards/btap/common_paths.rb +81 -0
- data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
- data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/materials_hvac.csv +1686 -0
- data/lib/openstudio-standards/btap/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +469 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +173 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +354 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +215 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +156 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +15 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +27 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/btap/geometry.rb +86 -6
- data/lib/openstudio-standards/btap/structure.rb +657 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
- data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
- data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
- data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
- data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
- data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
- data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
- data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
- data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
- data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
- data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
- data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
- data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
- data/lib/openstudio-standards/hvac/components/component.rb +39 -0
- data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
- data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
- data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
- data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
- data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
- data/lib/openstudio-standards/hvac/conversions.rb +222 -0
- data/lib/openstudio-standards/hvac/curves.rb +192 -0
- data/lib/openstudio-standards/hvac/helpers.rb +357 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
- data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
- data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
- data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
- data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
- data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
- data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
- data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
- data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
- data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
- data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
- data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
- data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
- data/lib/openstudio-standards/standards/Standards.Model.rb +45 -20
- data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
- data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +7 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
- data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
- data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +21 -37
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +115 -112
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +637 -249
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +75 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +25 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +18 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +68 -150
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +444 -134
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +17 -8
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +206 -32
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +75 -43
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
- data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards/weather/stat_file.rb +2 -2
- data/lib/openstudio-standards.rb +67 -38
- metadata +141 -50
- data/lib/openstudio-standards/hvac/components/create.rb +0 -169
- data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
- data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
|
@@ -0,0 +1,181 @@
|
|
|
1
|
+
module OpenstudioStandards
|
|
2
|
+
# The HVAC module provides methods create, modify, and get information about HVAC systems in the model
|
|
3
|
+
module HVAC
|
|
4
|
+
# @!group Component:Pump
|
|
5
|
+
# Methods to create, modify, and get information about pumps
|
|
6
|
+
|
|
7
|
+
# Get the pump flow rate (whether autosized or hard-sized)
|
|
8
|
+
#
|
|
9
|
+
# @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types: PumpConstantSpeed, PumpVariableSpeed, HeaderedPumpsConstantSpeed, HeaderedPumpsVariableSpeed
|
|
10
|
+
# return [Double] flow rate in m^3/s
|
|
11
|
+
def self.pump_get_rated_flow_rate(pump)
|
|
12
|
+
flow_m3_per_s = 0.0
|
|
13
|
+
if pump.to_PumpVariableSpeed.is_initialized || pump.to_PumpConstantSpeed.is_initialized
|
|
14
|
+
if pump.ratedFlowRate.is_initialized
|
|
15
|
+
flow_m3_per_s = pump.ratedFlowRate.get
|
|
16
|
+
elsif pump.autosizedRatedFlowRate.is_initialized
|
|
17
|
+
flow_m3_per_s = pump.autosizedRatedFlowRate.get
|
|
18
|
+
else
|
|
19
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.HVAC.pump', "For #{pump.name}, could not find rated pump Flow Rate.")
|
|
20
|
+
end
|
|
21
|
+
elsif pump.to_HeaderedPumpsVariableSpeed.is_initialized || pump.to_HeaderedPumpsConstantSpeed.is_initialized
|
|
22
|
+
if pump.totalRatedFlowRate.is_initialized
|
|
23
|
+
flow_m3_per_s = pump.totalRatedFlowRate.get
|
|
24
|
+
elsif pump.autosizedTotalRatedFlowRate.is_initialized
|
|
25
|
+
flow_m3_per_s = pump.autosizedTotalRatedFlowRate.get
|
|
26
|
+
else
|
|
27
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.HVAC.pump', "For #{pump.name}, could not find rated pump Flow Rate.")
|
|
28
|
+
end
|
|
29
|
+
end
|
|
30
|
+
|
|
31
|
+
return flow_m3_per_s
|
|
32
|
+
end
|
|
33
|
+
|
|
34
|
+
# Determines the pump power (W) based on flow rate, pressure rise,
|
|
35
|
+
# and total pump efficiency(impeller eff * motor eff).
|
|
36
|
+
# Uses the E+ default assumption of 0.78 impeller efficiency.
|
|
37
|
+
#
|
|
38
|
+
# @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
|
|
39
|
+
# PumpConstantSpeed, PumpVariableSpeed
|
|
40
|
+
# @return [Double] pump power in watts
|
|
41
|
+
def self.pump_get_power(pump)
|
|
42
|
+
# Get flow rate (whether autosized or hard-sized)
|
|
43
|
+
flow_m3_per_s = OpenstudioStandards::HVAC.pump_get_rated_flow_rate(pump)
|
|
44
|
+
|
|
45
|
+
# E+ default impeller efficiency
|
|
46
|
+
# http://bigladdersoftware.com/epx/docs/8-4/engineering-reference/component-sizing.html#pump-sizing
|
|
47
|
+
impeller_eff = 0.78
|
|
48
|
+
|
|
49
|
+
# Get the motor efficiency
|
|
50
|
+
motor_eff = pump.motorEfficiency
|
|
51
|
+
|
|
52
|
+
# Calculate the total efficiency
|
|
53
|
+
# which includes both motor and
|
|
54
|
+
# impeller efficiency.
|
|
55
|
+
pump_total_eff = impeller_eff * motor_eff
|
|
56
|
+
|
|
57
|
+
# Get the pressure rise (Pa)
|
|
58
|
+
pressure_rise_pa = pump.ratedPumpHead
|
|
59
|
+
|
|
60
|
+
# Calculate the pump power (W)
|
|
61
|
+
pump_power_w = pressure_rise_pa * flow_m3_per_s / pump_total_eff
|
|
62
|
+
|
|
63
|
+
return pump_power_w
|
|
64
|
+
end
|
|
65
|
+
|
|
66
|
+
# Determines the brake horsepower of the pump based on flow rate,
|
|
67
|
+
# pressure rise, and impeller efficiency.
|
|
68
|
+
#
|
|
69
|
+
# @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
|
|
70
|
+
# PumpConstantSpeed, PumpVariableSpeed
|
|
71
|
+
# @return [Double] brake horsepower
|
|
72
|
+
def self.pump_get_brake_horsepower(pump)
|
|
73
|
+
# Get flow rate (whether autosized or hard-sized)
|
|
74
|
+
flow_m3_per_s = OpenstudioStandards::HVAC.pump_get_rated_flow_rate(pump)
|
|
75
|
+
|
|
76
|
+
# E+ default impeller efficiency
|
|
77
|
+
# http://bigladdersoftware.com/epx/docs/8-4/engineering-reference/component-sizing.html#pump-sizing
|
|
78
|
+
impeller_eff = 0.78
|
|
79
|
+
|
|
80
|
+
# Get the pressure rise (Pa)
|
|
81
|
+
pressure_rise_pa = pump.ratedPumpHead
|
|
82
|
+
|
|
83
|
+
# Calculate the pump power (W)
|
|
84
|
+
pump_power_w = pressure_rise_pa * flow_m3_per_s / impeller_eff
|
|
85
|
+
|
|
86
|
+
# Convert to HP
|
|
87
|
+
pump_power_hp = pump_power_w / 745.7 # 745.7 W/HP
|
|
88
|
+
|
|
89
|
+
return pump_power_hp
|
|
90
|
+
end
|
|
91
|
+
|
|
92
|
+
# Determines the horsepower of the pump motor, including motor efficiency and pump impeller efficiency.
|
|
93
|
+
#
|
|
94
|
+
# @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
|
|
95
|
+
# PumpConstantSpeed, PumpVariableSpeed
|
|
96
|
+
# @return [Double] motor horsepower
|
|
97
|
+
def self.pump_get_motor_horsepower(pump)
|
|
98
|
+
# Get the pump power
|
|
99
|
+
pump_power_w = OpenstudioStandards::HVAC.pump_get_power(pump)
|
|
100
|
+
|
|
101
|
+
# Convert to HP
|
|
102
|
+
pump_hp = pump_power_w / 745.7 # 745.7 W/HP
|
|
103
|
+
|
|
104
|
+
return pump_hp
|
|
105
|
+
end
|
|
106
|
+
|
|
107
|
+
# Determines the rated watts per GPM of the pump
|
|
108
|
+
#
|
|
109
|
+
# @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
|
|
110
|
+
# PumpConstantSpeed, PumpVariableSpeed
|
|
111
|
+
# @return [Double] rated power consumption per flow in watts per gpm, W*min/gal
|
|
112
|
+
def self.pump_get_rated_w_per_gpm(pump)
|
|
113
|
+
# Get design power (whether autosized or hard-sized)
|
|
114
|
+
rated_power_w = 0
|
|
115
|
+
if pump.ratedPowerConsumption.is_initialized
|
|
116
|
+
rated_power_w = pump.ratedPowerConsumption.get
|
|
117
|
+
elsif pump.autosizedRatedPowerConsumption.is_initialized
|
|
118
|
+
rated_power_w = pump.autosizedRatedPowerConsumption.get
|
|
119
|
+
else
|
|
120
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.HVAC.pump', "For #{pump.name}, could not find rated pump power consumption, cannot determine w per gpm correctly.")
|
|
121
|
+
return 0.0
|
|
122
|
+
end
|
|
123
|
+
|
|
124
|
+
rated_m3_per_s = OpenstudioStandards::HVAC.pump_get_rated_flow_rate(pump)
|
|
125
|
+
rated_w_per_m3s = rated_power_w / rated_m3_per_s
|
|
126
|
+
rated_w_per_gpm = OpenStudio.convert(rated_w_per_m3s, 'W*s/m^3', 'W*min/gal').get
|
|
127
|
+
|
|
128
|
+
return rated_w_per_gpm
|
|
129
|
+
end
|
|
130
|
+
|
|
131
|
+
# Set the pump curve coefficients based on the specified control type.
|
|
132
|
+
#
|
|
133
|
+
# @param pump_variable_speed [OpenStudio::Model::PumpVariableSpeed, OpenStudio::Model::HeaderedPumpsVariableSpeed] variable speed pump or headered variable speed pumps object
|
|
134
|
+
# @param control_type [String] valid choices are Riding Curve, VSD No Reset, VSD DP Reset
|
|
135
|
+
# @return [Boolean] returns true if successful, false if not
|
|
136
|
+
def self.pump_variable_speed_set_control_type(pump_variable_speed, control_type: 'Riding Curve')
|
|
137
|
+
# Determine the coefficients
|
|
138
|
+
coeff_a = nil
|
|
139
|
+
coeff_b = nil
|
|
140
|
+
coeff_c = nil
|
|
141
|
+
coeff_d = nil
|
|
142
|
+
case control_type
|
|
143
|
+
when 'Constant Flow'
|
|
144
|
+
coeff_a = 0.0
|
|
145
|
+
coeff_b = 1.0
|
|
146
|
+
coeff_c = 0.0
|
|
147
|
+
coeff_d = 0.0
|
|
148
|
+
when 'Riding Curve'
|
|
149
|
+
coeff_a = 0.0
|
|
150
|
+
coeff_b = 3.2485
|
|
151
|
+
coeff_c = -4.7443
|
|
152
|
+
coeff_d = 2.5294
|
|
153
|
+
when 'VSD No Reset'
|
|
154
|
+
coeff_a = 0.0
|
|
155
|
+
coeff_b = 0.5726
|
|
156
|
+
coeff_c = -0.301
|
|
157
|
+
coeff_d = 0.7347
|
|
158
|
+
when 'VSD DP Reset'
|
|
159
|
+
coeff_a = 0.0
|
|
160
|
+
coeff_b = 0.0205
|
|
161
|
+
coeff_c = 0.4101
|
|
162
|
+
coeff_d = 0.5753
|
|
163
|
+
else
|
|
164
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.HVAC.pump', "Pump control type '#{control_type}' not recognized, pump coefficients will not be changed.")
|
|
165
|
+
return false
|
|
166
|
+
end
|
|
167
|
+
|
|
168
|
+
# Set the coefficients
|
|
169
|
+
pump_variable_speed.setCoefficient1ofthePartLoadPerformanceCurve(coeff_a)
|
|
170
|
+
pump_variable_speed.setCoefficient2ofthePartLoadPerformanceCurve(coeff_b)
|
|
171
|
+
pump_variable_speed.setCoefficient3ofthePartLoadPerformanceCurve(coeff_c)
|
|
172
|
+
pump_variable_speed.setCoefficient4ofthePartLoadPerformanceCurve(coeff_d)
|
|
173
|
+
pump_variable_speed.setPumpControlType('Intermittent')
|
|
174
|
+
|
|
175
|
+
# Append the control type to the pump name
|
|
176
|
+
# self.setName("#{self.name} #{control_type}")
|
|
177
|
+
|
|
178
|
+
return true
|
|
179
|
+
end
|
|
180
|
+
end
|
|
181
|
+
end
|