openstudio-standards 0.8.3 → 0.8.5.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (330) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.osm +30 -30
  3. data/data/geometry/ASHRAECourthouse.osm +22 -22
  4. data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
  5. data/data/geometry/DEER_Asm.osm +1 -1
  6. data/data/geometry/DEER_ECC.osm +1 -1
  7. data/data/geometry/DEER_EPr.osm +1 -1
  8. data/data/geometry/DEER_ERC.osm +1 -1
  9. data/data/geometry/DEER_ESe.osm +1 -1
  10. data/data/geometry/DEER_EUn.osm +1 -1
  11. data/data/geometry/DEER_Hsp.osm +1 -1
  12. data/data/geometry/DEER_Htl.osm +1 -1
  13. data/data/geometry/DEER_MBT.osm +1 -1
  14. data/data/geometry/DEER_MFm.osm +1 -1
  15. data/data/geometry/DEER_Nrs.osm +1 -1
  16. data/data/geometry/DEER_OfL.osm +1 -1
  17. data/data/geometry/DEER_OfS.osm +1 -1
  18. data/data/geometry/DEER_RFF.osm +1 -1
  19. data/data/geometry/DEER_RSD.osm +1 -1
  20. data/data/geometry/DEER_Rt3.osm +1 -1
  21. data/data/geometry/DEER_RtS.osm +1 -1
  22. data/data/standards/export_OpenStudio_libraries.rb +2 -3
  23. data/data/standards/test_performance_expected_dd_results.csv +42 -42
  24. data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
  25. data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
  26. data/lib/openstudio-standards/btap/activity.rb +480 -0
  27. data/lib/openstudio-standards/btap/attributes.rb +166 -0
  28. data/lib/openstudio-standards/btap/bridging.rb +561 -1402
  29. data/lib/openstudio-standards/btap/btap.rb +4 -2
  30. data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
  31. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
  32. data/lib/openstudio-standards/btap/common_paths.rb +81 -0
  33. data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +52 -0
  34. data/lib/openstudio-standards/btap/common_resources/Constructions.csv +37 -0
  35. data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
  36. data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
  37. data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
  38. data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +1270 -0
  39. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
  40. data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +2256 -0
  41. data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
  42. data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +2315 -0
  43. data/lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv +925 -0
  44. data/lib/openstudio-standards/btap/common_resources/lighting.csv +364 -0
  45. data/lib/openstudio-standards/btap/common_resources/lighting_sets.csv +2667 -0
  46. data/lib/openstudio-standards/btap/common_resources/locations.csv +75 -0
  47. data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +35 -0
  48. data/lib/openstudio-standards/btap/common_resources/materials_hvac.csv +1686 -0
  49. data/lib/openstudio-standards/btap/common_resources/materials_lighting.csv +267 -0
  50. data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +164 -0
  51. data/lib/openstudio-standards/btap/costing/README.md +502 -0
  52. data/lib/openstudio-standards/btap/costing/btap_costing.rb +469 -0
  53. data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
  54. data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
  55. data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
  56. data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
  57. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +173 -0
  58. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +354 -0
  59. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
  60. data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
  61. data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
  62. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +215 -0
  63. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
  64. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +156 -0
  65. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
  66. data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
  67. data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
  68. data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
  69. data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
  70. data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
  71. data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
  72. data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
  73. data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
  74. data/lib/openstudio-standards/btap/costing/test_list.txt +15 -0
  75. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +27 -0
  76. data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
  77. data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
  78. data/lib/openstudio-standards/btap/geometry.rb +86 -6
  79. data/lib/openstudio-standards/btap/structure.rb +657 -0
  80. data/lib/openstudio-standards/constructions/modify.rb +2 -1
  81. data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
  82. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
  83. data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
  84. data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
  85. data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
  86. data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
  87. data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
  88. data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
  89. data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
  90. data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
  91. data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
  92. data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
  93. data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
  94. data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
  95. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
  96. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
  97. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
  98. data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
  99. data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
  100. data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
  101. data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
  102. data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
  103. data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
  104. data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
  105. data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
  106. data/lib/openstudio-standards/hvac/components/component.rb +39 -0
  107. data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
  108. data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
  109. data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
  110. data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
  111. data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
  112. data/lib/openstudio-standards/hvac/conversions.rb +222 -0
  113. data/lib/openstudio-standards/hvac/curves.rb +192 -0
  114. data/lib/openstudio-standards/hvac/helpers.rb +357 -0
  115. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
  116. data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
  117. data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
  118. data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
  119. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
  120. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
  121. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
  122. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
  123. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  124. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  125. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  126. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
  127. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  128. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
  129. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  130. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  131. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
  132. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
  133. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
  134. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
  135. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
  136. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
  137. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
  138. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
  139. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
  140. data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
  141. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
  142. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
  143. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
  144. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
  145. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
  146. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
  147. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
  148. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
  149. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
  150. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
  151. data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
  152. data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
  153. data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
  154. data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
  155. data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
  156. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
  157. data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
  158. data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
  159. data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
  160. data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
  161. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
  162. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
  163. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
  164. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
  165. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
  166. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
  167. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
  168. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
  169. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
  170. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
  171. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
  172. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
  173. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
  174. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
  175. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
  176. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
  177. data/lib/openstudio-standards/standards/Standards.Model.rb +45 -20
  178. data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
  179. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
  180. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
  181. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
  182. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
  183. data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
  184. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
  185. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
  186. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
  187. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
  188. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
  189. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
  191. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  192. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
  193. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
  194. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
  195. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  196. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
  197. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
  198. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
  199. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
  200. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
  202. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
  203. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
  204. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
  205. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
  206. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  207. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
  208. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
  209. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
  210. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
  211. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
  212. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
  213. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
  214. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
  215. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
  216. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
  217. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  218. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
  219. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  220. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
  221. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
  222. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
  223. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
  224. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
  225. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
  226. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
  227. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
  228. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
  229. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
  230. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
  231. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
  232. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
  233. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
  234. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
  235. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +7 -1
  236. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
  237. data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
  238. data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
  239. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +21 -37
  240. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
  241. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
  242. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
  243. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
  244. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
  245. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
  246. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +115 -112
  247. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +637 -249
  248. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
  249. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
  250. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
  251. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +75 -7
  252. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +25 -1
  253. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
  254. data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
  255. data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
  256. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
  257. data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
  258. data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
  259. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
  260. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +18 -6
  261. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
  262. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
  263. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
  264. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
  265. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
  266. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +68 -150
  267. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +444 -134
  268. data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
  269. data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
  270. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
  271. data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
  272. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +17 -8
  273. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
  274. data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
  275. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
  276. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
  277. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
  278. data/lib/openstudio-standards/standards/necb/README.md +343 -0
  279. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
  280. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +206 -32
  281. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +75 -43
  282. data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
  283. data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
  284. data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
  285. data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
  286. data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
  287. data/lib/openstudio-standards/utilities/logging.rb +18 -14
  288. data/lib/openstudio-standards/version.rb +1 -1
  289. data/lib/openstudio-standards/weather/modify.rb +2 -2
  290. data/lib/openstudio-standards/weather/stat_file.rb +2 -2
  291. data/lib/openstudio-standards.rb +67 -38
  292. metadata +141 -50
  293. data/lib/openstudio-standards/hvac/components/create.rb +0 -169
  294. data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
  295. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
  296. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
  297. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
  298. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
  299. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
  300. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
  301. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
  302. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
  303. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
  304. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
  305. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
  306. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
  307. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
  308. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
  309. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
  310. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
  311. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
  312. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
  313. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
  314. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
  315. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
  316. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
  317. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
  318. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
  319. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
  320. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
  321. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
  322. data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
  323. data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
  324. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
  325. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
  326. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
  327. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
  328. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
  329. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
  330. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
@@ -105,8 +105,8 @@ Standard.class_eval do
105
105
  model_update_exhaust_fan_efficiency(model)
106
106
  model_update_fan_efficiency(model)
107
107
  # rename air loop and plant loop nodes for readability
108
- rename_air_loop_nodes(model)
109
- rename_plant_loop_nodes(model)
108
+ OpenstudioStandards::HVAC.rename_air_loop_nodes(model)
109
+ OpenstudioStandards::HVAC.rename_plant_loop_nodes(model)
110
110
  # remove unused objects
111
111
  model_remove_unused_resource_objects(model)
112
112
  # Add output variables for debugging
@@ -118,6 +118,28 @@ Standard.class_eval do
118
118
  return measure_model
119
119
  end
120
120
 
121
+ # Loads a JSON file containing the space type map into a hash
122
+ #
123
+ # @param hvac_map_file [String] path to JSON file, relative to the /data folder
124
+ # @return [Hash] returns a hash that contains the space type map
125
+ def load_hvac_map(hvac_map_file)
126
+ # Load the geometry .osm from relative to the data folder
127
+ rel_path_to_hvac_map = "../../../../../data/#{hvac_map_file}"
128
+
129
+ # Load the JSON depending on whether running from normal gem location
130
+ # or from the embedded location in the OpenStudio CLI
131
+ if File.dirname(__FILE__)[0] == ':'
132
+ # running from embedded location in OpenStudio CLI
133
+ hvac_map_string = load_resource_relative(rel_path_to_hvac_map)
134
+ hvac_map = JSON.parse(hvac_map_string)
135
+ else
136
+ abs_path = File.join(File.dirname(__FILE__), rel_path_to_hvac_map)
137
+ hvac_map = JSON.parse(File.read(abs_path)) if File.exist?(abs_path)
138
+ end
139
+
140
+ return hvac_map
141
+ end
142
+
121
143
  # Replaces the contents of 'model_to_replace' with the contents of 'new_model.'
122
144
  # This method can be used when the memory location of model_to_replace needs
123
145
  # to be preserved, for example, when a measure is passed.
@@ -183,6 +205,105 @@ Standard.class_eval do
183
205
  return true
184
206
  end
185
207
 
208
+
209
+ # load a model into OS & version translates, exiting and erroring if a problem is found
210
+ #
211
+ # @param model_path_string [String] file path to OpenStudio model file
212
+ # @return [OpenStudio::Model::Model] OpenStudio model object
213
+ def safe_load_model(model_path_string)
214
+ model_path = OpenStudio::Path.new(model_path_string)
215
+ if OpenStudio.exists(model_path)
216
+ version_translator = OpenStudio::OSVersion::VersionTranslator.new
217
+ model = version_translator.loadModel(model_path)
218
+ if model.empty?
219
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', "Version translation failed for #{model_path_string}")
220
+ return false
221
+ else
222
+ model = model.get
223
+ end
224
+ else
225
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', "#{model_path_string} couldn't be found")
226
+ return false
227
+ end
228
+ return model
229
+ end
230
+
231
+ # Remove all resource objects in the model
232
+ #
233
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
234
+ # @return [OpenStudio::Model::Model] OpenStudio model object
235
+ def strip_model(model)
236
+ # remove all materials
237
+ model.getMaterials.each(&:remove)
238
+
239
+ # remove all constructions
240
+ model.getConstructions.each(&:remove)
241
+
242
+ # remove performance curves
243
+ model.getCurves.each do |curve|
244
+ model.removeObject(curve.handle)
245
+ end
246
+
247
+ # remove all zone equipment
248
+ model.getThermalZones.sort.each do |zone|
249
+ zone.equipment.each(&:remove)
250
+ end
251
+
252
+ # remove all thermostats
253
+ model.getThermostatSetpointDualSetpoints.each(&:remove)
254
+
255
+ # remove all people
256
+ model.getPeoples.each(&:remove)
257
+ model.getPeopleDefinitions.each(&:remove)
258
+
259
+ # remove all lights
260
+ model.getLightss.each(&:remove)
261
+ model.getLightsDefinitions.each(&:remove)
262
+
263
+ # remove all electric equipment
264
+ model.getElectricEquipments.each(&:remove)
265
+ model.getElectricEquipmentDefinitions.each(&:remove)
266
+
267
+ # remove all gas equipment
268
+ model.getGasEquipments.each(&:remove)
269
+ model.getGasEquipmentDefinitions.each(&:remove)
270
+
271
+ # remove all outdoor air
272
+ model.getDesignSpecificationOutdoorAirs.each(&:remove)
273
+
274
+ # remove all infiltration
275
+ model.getSpaceInfiltrationDesignFlowRates.each(&:remove)
276
+
277
+ # Remove all internal mass
278
+ model.getInternalMasss.each(&:remove)
279
+
280
+ # Remove all internal mass defs
281
+ model.getInternalMassDefinitions.each(&:remove)
282
+
283
+ # Remove all thermal zones
284
+ model.getThermalZones.each(&:remove)
285
+
286
+ # Remove all schedules
287
+ model.getSchedules.each(&:remove)
288
+
289
+ # Remove all schedule type limits
290
+ model.getScheduleTypeLimitss.each(&:remove)
291
+
292
+ # Remove the sizing parameters
293
+ model.getSizingParameters.remove
294
+
295
+ # Remove the design days
296
+ model.getDesignDays.each(&:remove)
297
+
298
+ # Remove the rendering colors
299
+ model.getRenderingColors.each(&:remove)
300
+
301
+ # Remove the daylight controls
302
+ model.getDaylightingControls.each(&:remove)
303
+
304
+ return model
305
+ end
306
+
186
307
  # Read the space type to space map from the model
187
308
  # instead of relying on an externally-defined mapping.
188
309
  def get_space_type_maps_from_model(model)
@@ -242,10 +363,13 @@ Standard.class_eval do
242
363
  space_type_apply_rendering_color(space_type)
243
364
 
244
365
  # Loads
245
- space_type_apply_internal_loads(space_type, true, true, true, true, true)
366
+ space_type_apply_internal_loads(space_type)
246
367
 
247
368
  # Schedules
248
- space_type_apply_internal_load_schedules(space_type, true, true, true, true, true, true)
369
+ space_type_apply_internal_load_schedules(space_type)
370
+
371
+ # Thermostat Schedules
372
+ space_type_apply_thermostat_schedules(space_type)
249
373
  end
250
374
 
251
375
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Finished applying space types (loads)')
@@ -1421,18 +1545,9 @@ Standard.class_eval do
1421
1545
  model.getFanOnOffs.sort.each { |obj| prototype_fan_apply_prototype_fan_efficiency(obj) }
1422
1546
  model.getFanZoneExhausts.sort.each { |obj| prototype_fan_apply_prototype_fan_efficiency(obj) }
1423
1547
 
1424
- # Gas Heating Coil
1425
- model.getCoilHeatingGass.sort.each { |obj| coil_heating_gas_apply_prototype_efficiency(obj) }
1426
-
1427
1548
  # Add Economizers
1428
1549
  apply_economizers(climate_zone, model)
1429
1550
 
1430
- # @todo What is the logic behind hard-sizing hot water coil convergence tolerances?
1431
- model.getControllerWaterCoils.sort.each { |obj| controller_water_coil_set_convergence_limits(obj) }
1432
-
1433
- # Adjust defrost curve limits for coil heating dx single speed
1434
- model.getCoilHeatingDXSingleSpeeds.sort.each { |obj| coil_heating_dx_single_speed_apply_defrost_eir_curve_limits(obj) }
1435
-
1436
1551
  # Pump part load performances
1437
1552
  model.getPumpVariableSpeeds.sort.each { |obj| pump_variable_speed_control_type(obj) }
1438