openstudio-standards 0.8.3 → 0.8.5.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (330) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.osm +30 -30
  3. data/data/geometry/ASHRAECourthouse.osm +22 -22
  4. data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
  5. data/data/geometry/DEER_Asm.osm +1 -1
  6. data/data/geometry/DEER_ECC.osm +1 -1
  7. data/data/geometry/DEER_EPr.osm +1 -1
  8. data/data/geometry/DEER_ERC.osm +1 -1
  9. data/data/geometry/DEER_ESe.osm +1 -1
  10. data/data/geometry/DEER_EUn.osm +1 -1
  11. data/data/geometry/DEER_Hsp.osm +1 -1
  12. data/data/geometry/DEER_Htl.osm +1 -1
  13. data/data/geometry/DEER_MBT.osm +1 -1
  14. data/data/geometry/DEER_MFm.osm +1 -1
  15. data/data/geometry/DEER_Nrs.osm +1 -1
  16. data/data/geometry/DEER_OfL.osm +1 -1
  17. data/data/geometry/DEER_OfS.osm +1 -1
  18. data/data/geometry/DEER_RFF.osm +1 -1
  19. data/data/geometry/DEER_RSD.osm +1 -1
  20. data/data/geometry/DEER_Rt3.osm +1 -1
  21. data/data/geometry/DEER_RtS.osm +1 -1
  22. data/data/standards/export_OpenStudio_libraries.rb +2 -3
  23. data/data/standards/test_performance_expected_dd_results.csv +42 -42
  24. data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
  25. data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
  26. data/lib/openstudio-standards/btap/activity.rb +480 -0
  27. data/lib/openstudio-standards/btap/attributes.rb +166 -0
  28. data/lib/openstudio-standards/btap/bridging.rb +561 -1402
  29. data/lib/openstudio-standards/btap/btap.rb +4 -2
  30. data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
  31. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
  32. data/lib/openstudio-standards/btap/common_paths.rb +81 -0
  33. data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +52 -0
  34. data/lib/openstudio-standards/btap/common_resources/Constructions.csv +37 -0
  35. data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
  36. data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
  37. data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
  38. data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +1270 -0
  39. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
  40. data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +2256 -0
  41. data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
  42. data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +2315 -0
  43. data/lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv +925 -0
  44. data/lib/openstudio-standards/btap/common_resources/lighting.csv +364 -0
  45. data/lib/openstudio-standards/btap/common_resources/lighting_sets.csv +2667 -0
  46. data/lib/openstudio-standards/btap/common_resources/locations.csv +75 -0
  47. data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +35 -0
  48. data/lib/openstudio-standards/btap/common_resources/materials_hvac.csv +1686 -0
  49. data/lib/openstudio-standards/btap/common_resources/materials_lighting.csv +267 -0
  50. data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +164 -0
  51. data/lib/openstudio-standards/btap/costing/README.md +502 -0
  52. data/lib/openstudio-standards/btap/costing/btap_costing.rb +469 -0
  53. data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
  54. data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
  55. data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
  56. data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
  57. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +173 -0
  58. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +354 -0
  59. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
  60. data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
  61. data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
  62. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +215 -0
  63. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
  64. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +156 -0
  65. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
  66. data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
  67. data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
  68. data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
  69. data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
  70. data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
  71. data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
  72. data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
  73. data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
  74. data/lib/openstudio-standards/btap/costing/test_list.txt +15 -0
  75. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +27 -0
  76. data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
  77. data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
  78. data/lib/openstudio-standards/btap/geometry.rb +86 -6
  79. data/lib/openstudio-standards/btap/structure.rb +657 -0
  80. data/lib/openstudio-standards/constructions/modify.rb +2 -1
  81. data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
  82. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
  83. data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
  84. data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
  85. data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
  86. data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
  87. data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
  88. data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
  89. data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
  90. data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
  91. data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
  92. data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
  93. data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
  94. data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
  95. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
  96. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
  97. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
  98. data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
  99. data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
  100. data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
  101. data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
  102. data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
  103. data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
  104. data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
  105. data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
  106. data/lib/openstudio-standards/hvac/components/component.rb +39 -0
  107. data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
  108. data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
  109. data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
  110. data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
  111. data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
  112. data/lib/openstudio-standards/hvac/conversions.rb +222 -0
  113. data/lib/openstudio-standards/hvac/curves.rb +192 -0
  114. data/lib/openstudio-standards/hvac/helpers.rb +357 -0
  115. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
  116. data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
  117. data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
  118. data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
  119. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
  120. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
  121. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
  122. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
  123. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  124. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  125. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  126. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
  127. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  128. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
  129. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  130. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  131. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
  132. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
  133. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
  134. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
  135. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
  136. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
  137. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
  138. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
  139. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
  140. data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
  141. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
  142. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
  143. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
  144. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
  145. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
  146. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
  147. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
  148. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
  149. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
  150. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
  151. data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
  152. data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
  153. data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
  154. data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
  155. data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
  156. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
  157. data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
  158. data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
  159. data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
  160. data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
  161. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
  162. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
  163. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
  164. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
  165. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
  166. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
  167. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
  168. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
  169. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
  170. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
  171. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
  172. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
  173. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
  174. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
  175. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
  176. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
  177. data/lib/openstudio-standards/standards/Standards.Model.rb +45 -20
  178. data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
  179. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
  180. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
  181. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
  182. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
  183. data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
  184. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
  185. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
  186. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
  187. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
  188. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
  189. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
  191. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  192. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
  193. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
  194. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
  195. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  196. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
  197. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
  198. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
  199. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
  200. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
  202. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
  203. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
  204. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
  205. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
  206. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  207. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
  208. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
  209. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
  210. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
  211. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
  212. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
  213. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
  214. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
  215. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
  216. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
  217. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  218. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
  219. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  220. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
  221. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
  222. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
  223. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
  224. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
  225. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
  226. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
  227. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
  228. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
  229. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
  230. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
  231. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
  232. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
  233. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
  234. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
  235. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +7 -1
  236. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
  237. data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
  238. data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
  239. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +21 -37
  240. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
  241. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
  242. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
  243. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
  244. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
  245. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
  246. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +115 -112
  247. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +637 -249
  248. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
  249. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
  250. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
  251. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +75 -7
  252. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +25 -1
  253. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
  254. data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
  255. data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
  256. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
  257. data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
  258. data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
  259. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
  260. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +18 -6
  261. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
  262. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
  263. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
  264. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
  265. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
  266. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +68 -150
  267. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +444 -134
  268. data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
  269. data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
  270. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
  271. data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
  272. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +17 -8
  273. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
  274. data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
  275. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
  276. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
  277. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
  278. data/lib/openstudio-standards/standards/necb/README.md +343 -0
  279. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
  280. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +206 -32
  281. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +75 -43
  282. data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
  283. data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
  284. data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
  285. data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
  286. data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
  287. data/lib/openstudio-standards/utilities/logging.rb +18 -14
  288. data/lib/openstudio-standards/version.rb +1 -1
  289. data/lib/openstudio-standards/weather/modify.rb +2 -2
  290. data/lib/openstudio-standards/weather/stat_file.rb +2 -2
  291. data/lib/openstudio-standards.rb +67 -38
  292. metadata +141 -50
  293. data/lib/openstudio-standards/hvac/components/create.rb +0 -169
  294. data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
  295. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
  296. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
  297. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
  298. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
  299. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
  300. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
  301. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
  302. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
  303. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
  304. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
  305. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
  306. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
  307. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
  308. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
  309. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
  310. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
  311. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
  312. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
  313. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
  314. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
  315. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
  316. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
  317. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
  318. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
  319. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
  320. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
  321. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
  322. data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
  323. data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
  324. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
  325. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
  326. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
  327. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
  328. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
  329. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
  330. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
@@ -0,0 +1,215 @@
1
+ class String
2
+ def underscore
3
+ self.gsub(/::/, '/').
4
+ gsub(/([A-Z]+)([A-Z][a-z])/, '\1_\2').
5
+ gsub(/([a-z\d])([A-Z])/, '\1_\2').
6
+ tr("-", "_").
7
+ downcase
8
+ end
9
+ end
10
+
11
+ class BTAPCosting
12
+ def cost_audit_envelope(model, prototype_creator)
13
+ @attributes.surface_types.each do |surface_type|
14
+ @costing_report["envelope"]["#{surface_type.underscore}_cost"] = 0.00
15
+ @costing_report["envelope"]["#{surface_type.underscore}_area_m2"] = 0.0
16
+ @costing_report["envelope"]["#{surface_type.underscore}_cost_per_m2"] = 0.00
17
+ end
18
+
19
+ @costing_report["envelope"]["construction_costs"] = []
20
+
21
+ generate_construction_cost_database_for_city(@costing_report["city"], @costing_report["province_state"])
22
+
23
+ totEnvCost = 0
24
+
25
+ @attributes.spaces.each do |space|
26
+ # Get SpaceType defined for space.. if not defined it will skip the spacetype. May have to deal with Attic spaces.
27
+ if space.spaceType.empty? or space.spaceType.get.standardsSpaceType.empty? or space.spaceType.get.standardsBuildingType.empty?
28
+ raise ("standards Space type and building type is not defined for space:#{space.name.get}. Skipping this space for costing.")
29
+ end
30
+
31
+ @attributes.surface_types.each do |surface_type|
32
+ # Get Costs for this construction type. This will get the cost for the particular construction type
33
+ # for all rsi levels for this location. This has been collected by the API costs data. Note that a space_type
34
+ # of "- undefined -" will create a nil construction_set!
35
+
36
+ if space.construction_set.nil?
37
+ cost_range_hash = {}
38
+ else
39
+ cost_range_hash = @costing_database['constructions_costs'].select { |construction|
40
+ construction['construction_type_name'] == space.construction_set[surface_type] &&
41
+ construction['province_state'] == @costing_report["province_state"] &&
42
+ construction['city'] == @costing_report["city"]
43
+ }
44
+ end
45
+
46
+ # We don't need all the information, just the rsi and cost. However, for windows rsi = 1/u_w_per_m2_k
47
+ surfaceIsGlazing = (
48
+ surface_type == 'ExteriorFixedWindow' || surface_type == 'ExteriorOperableWindow' ||
49
+ surface_type == 'ExteriorSkylight' || surface_type == 'ExteriorTubularDaylightDiffuser' ||
50
+ surface_type == 'ExteriorTubularDaylightDome' || surface_type == 'ExteriorGlassDoor')
51
+ if surfaceIsGlazing
52
+ cost_range_array = cost_range_hash.map { |cost|
53
+ [
54
+ (1.0 / cost['u_w_per_m2_k'].to_f),
55
+ cost['total_cost_with_op']
56
+ ]
57
+ }
58
+ else
59
+ cost_range_array = cost_range_hash.map { |cost|
60
+ [
61
+ cost['rsi_k_m2_per_w'],
62
+ cost['total_cost_with_op']
63
+ ]
64
+ }
65
+ end
66
+ # Sorted based on rsi.
67
+ cost_range_array.sort! { |a, b| a[0] <=> b[0] }
68
+
69
+ # Iterate through actual surfaces in the model of surface_type.
70
+ numSurfType = 0
71
+ space.surfaces_hash[surface_type].each do |surface|
72
+ numSurfType = numSurfType + 1
73
+
74
+ # Get RSI of existing model surface (actually returns rsi for glazings too!).
75
+ # Make an array of constructions to use with surfaces_get_conductance method which replaces the get_rsi
76
+ # method
77
+ rsi = 1 / (OpenstudioStandards::Constructions.construction_get_conductance(OpenStudio::Model::getConstructionByName(surface.model, surface.construction.get.name.to_s).get))
78
+
79
+
80
+ #Check to see if it is in range
81
+
82
+
83
+ # Use the cost_range_array to interpolate the estimated cost for the given rsi.
84
+ # Note that window costs in the API data use U-value, which was converted to rsi for cost_range_array above
85
+ exterpolate_percentage_range = 30.0
86
+ cost = interpolate(x_y_array: cost_range_array, x2: rsi, exterpolate_percentage_range: exterpolate_percentage_range)
87
+
88
+
89
+ # If the cost is nil, that means the rsi is out of range. Flag in the report.
90
+ if cost.nil?
91
+ if !cost_range_array.empty?
92
+ notes = "Warning! RSI out of the range (#{'%.2f' % rsi}) or cost is 0!. Range for #{space.construction_set[surface_type]} is #{'%.2f' % cost_range_array.first[0]}-#{'%.2f' % cost_range_array.last[0]}."
93
+ cost = 0.0
94
+ else
95
+ notes = "No cost found for this! So Cost is set to 0.0!"
96
+ cost = 0.0
97
+ end
98
+ elsif cost.nan?
99
+ raise("the values for cost and conductance for #{space.construction_set[surface_type]} cannot be interpolated...cannot create an equation of a line from #{cost_range_array.sort.uniq}. Check construction database and either eliminate the errant row, or set the x value to an appropriate number. ")
100
+ else
101
+ #Tell user if we are extrapolating outside of library.
102
+ array = cost_range_array.sort { |a, b| a[0] <=> b[0] }
103
+ if rsi < (array.first[0].to_f) || rsi > (array.last[0].to_f)
104
+ notes = "RSI out of the range (#{'%.2f' % rsi}). Range for #{space.construction_set[surface_type]} is #{'%.2f' % cost_range_array.first[0]}-#{'%.2f' % cost_range_array.last[0]}.Using extrapolation up to +/-30% of library boundaries. "
105
+ else
106
+ notes = "OK"
107
+ end
108
+ end
109
+
110
+ # Calculate SHGC/film cost
111
+ film_cost = 0.0
112
+ if surfaceIsGlazing
113
+ #Get SHGC from surface.
114
+ shgc = OpenstudioStandards::Constructions.construction_get_solar_transmittance(surface.construction.get.to_Construction.get)
115
+ # Get the closest value in materials_glazing sheet of SolarFilms.
116
+ material_row = @costing_database["raw"]["materials_glazing"].select{ |row| row['material_type'] == 'Solarfilms' }.min_by {|row| (shgc.to_f - row['solar_heat_gain_coefficient'].to_f).abs}
117
+ standard_film_cost = getCost(material_row['description'], material_row, 1.0)
118
+ regional_factors = get_regional_cost_factors(@costing_report['province_state'], @costing_report['city'], material_row)
119
+ # mult regional cost and sum costs. Zip adds the arrays together, map multiplies each row and divides by 100.0 since the regional factor is in percents.
120
+ film_cost = standard_film_cost.zip(regional_factors).map{|cost,region_factor| cost * region_factor / 100.0}.inject(0, :+)
121
+ end
122
+
123
+
124
+ testSurfName = surface.name.to_s
125
+ testSpaceName = space.name.to_s
126
+ surfArea = surface.netArea * space.thermalZone.get.multiplier
127
+ surfAreaft = (OpenStudio.convert(surfArea, "m^2", "ft^2").get).to_f
128
+ surfCost = (cost + film_cost) * surfAreaft
129
+ totEnvCost = totEnvCost + surfCost
130
+ name = ""
131
+
132
+ # Bin the costing by construction standard type and rsi
133
+ if space.construction_set.nil?
134
+ name = "undefined space type_#{(1.0 / rsi).round(3)}"
135
+ else
136
+ name = "#{space.construction_set[surface_type]}"
137
+ end
138
+ row = @costing_report["envelope"]["construction_costs"].detect { |row| (row['name'] == name) && (row['conductance'].round(3) == ((1.0 / rsi).round(3))) }
139
+ if row.nil?
140
+ @costing_report["envelope"]["construction_costs"] << {'name' => name, 'conductance' => ((1.0 / rsi).round(3)), 'area' => (surfArea.round(2)), 'cost' => (surfCost.round(2)), 'cost_per_area' => (surfCost / surfArea).round(2), 'note' => "Surf ##{numSurfType}: #{notes}"}
141
+ else
142
+ # Not using += for @costing_report additions so that output can be properly rounded
143
+ row['area'] = (row['area'] + surfArea).round(2)
144
+ row['cost'] = (row['cost'] + surfCost).round(2)
145
+ row['cost_per_area'] = ((row['cost'] / row['area']).to_f.round(2))
146
+ row['note'] += " / #{numSurfType}: #{notes}"
147
+ end
148
+ # Not using += for @costing_report additions so that output can be properly rounded
149
+ @costing_report["envelope"]["#{surface_type.underscore}_cost"] = (@costing_report["envelope"]["#{surface_type.underscore}_cost"] + surfCost).round(2)
150
+ @costing_report["envelope"]["#{surface_type.underscore}_area_m2"] = (@costing_report["envelope"]["#{surface_type.underscore}_area_m2"] + surfArea).round(2)
151
+ @costing_report["envelope"]["#{surface_type.underscore}_cost_per_m2"] = (@costing_report["envelope"]["#{surface_type.underscore}_cost"] / @costing_report["envelope"]["#{surface_type.underscore}_area_m2"]).round(2)
152
+ end # surfaces of surface type
153
+ end # surface_type
154
+ end # spaces
155
+
156
+ @costing_report["envelope"]['total_envelope_cost'] = totEnvCost.to_f.round(2)
157
+ puts "\nEnvelope costing data successfully generated. Total envelope cost is $#{totEnvCost.to_f.round(2)}"
158
+
159
+ return totEnvCost
160
+ end
161
+
162
+ def cost_construction(construction, location, type = 'opaque')
163
+
164
+ material_layers = "material_#{type}_id_layers"
165
+ material_id = "materials_#{type}_id"
166
+ materials_database = @costing_database["raw"]["materials_#{type}"]
167
+
168
+ total_with_op = 0.0
169
+ material_cost_pairs = []
170
+ construction[material_layers].split(',').reject { |c| c.empty? }.each do |material_index|
171
+ material = materials_database.find { |data| data[material_id].to_s == material_index.to_s }
172
+ if material.nil?
173
+ puts "material error..could not find material #{material_index} in #{materials_database}"
174
+ raise()
175
+ else
176
+ costing_data = @costing_database['costs'].detect { |data| data['id'].to_s.upcase == material['id'].to_s.upcase }
177
+ if costing_data.nil?
178
+ puts "This material id #{material['id']} was not found in the costing database. Skipping. This construction will be inaccurate. "
179
+ raise()
180
+ else
181
+ regional_material, regional_installation = get_regional_cost_factors(location['province_state'], location['city'], material)
182
+
183
+ # Get cost information from lookup.
184
+ # Note that "glazing" types don't have a 'quantity' hash entry!
185
+ # Don't need "and" below but using in-case this hash field is added in the future.
186
+ if type == 'glazing' and material['quantity'].to_f == 0.0
187
+ material['quantity'] = '1.0'
188
+ end
189
+ material_cost = costing_data['baseCosts']['materialOpCost'].to_f * material['material_mult'].to_f
190
+ labour_cost = costing_data['baseCosts']['laborOpCost'].to_f * material['labour_mult'].to_f
191
+ equipment_cost = costing_data['baseCosts']['equipmentOpCost'].to_f
192
+ layer_cost = (((material_cost * regional_material / 100.0) + (labour_cost * regional_installation / 100.0) + equipment_cost) * material['quantity'].to_f).round(2)
193
+ material_cost_pairs << {material_id.to_s => material_index,
194
+ 'cost' => layer_cost}
195
+ total_with_op += layer_cost
196
+ end
197
+ end
198
+ end
199
+ new_construction = {
200
+ 'province_state' => location['province_state'],
201
+ 'city' => location['city'],
202
+ "construction_type_name" => construction["construction_type_name"],
203
+ 'description' => construction["description"],
204
+ 'intended_surface_type' => construction["intended_surface_type"],
205
+ 'standards_construction_type' => construction["standards_construction_type"],
206
+ 'rsi_k_m2_per_w' => construction['rsi_k_m2_per_w'].to_f,
207
+ 'zone' => construction['climate_zone'],
208
+ 'fenestration_type' => construction['fenestration_type'],
209
+ 'u_w_per_m2_k' => construction['u_w_per_m2_k'],
210
+ 'materials' => material_cost_pairs,
211
+ 'total_cost_with_op' => total_with_op}
212
+
213
+ @costing_database['constructions_costs'] << new_construction
214
+ end
215
+ end