openstudio-standards 0.8.3 → 0.8.5.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.osm +30 -30
- data/data/geometry/ASHRAECourthouse.osm +22 -22
- data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
- data/data/geometry/DEER_Asm.osm +1 -1
- data/data/geometry/DEER_ECC.osm +1 -1
- data/data/geometry/DEER_EPr.osm +1 -1
- data/data/geometry/DEER_ERC.osm +1 -1
- data/data/geometry/DEER_ESe.osm +1 -1
- data/data/geometry/DEER_EUn.osm +1 -1
- data/data/geometry/DEER_Hsp.osm +1 -1
- data/data/geometry/DEER_Htl.osm +1 -1
- data/data/geometry/DEER_MBT.osm +1 -1
- data/data/geometry/DEER_MFm.osm +1 -1
- data/data/geometry/DEER_Nrs.osm +1 -1
- data/data/geometry/DEER_OfL.osm +1 -1
- data/data/geometry/DEER_OfS.osm +1 -1
- data/data/geometry/DEER_RFF.osm +1 -1
- data/data/geometry/DEER_RSD.osm +1 -1
- data/data/geometry/DEER_Rt3.osm +1 -1
- data/data/geometry/DEER_RtS.osm +1 -1
- data/data/standards/export_OpenStudio_libraries.rb +2 -3
- data/data/standards/test_performance_expected_dd_results.csv +42 -42
- data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
- data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
- data/lib/openstudio-standards/btap/activity.rb +480 -0
- data/lib/openstudio-standards/btap/attributes.rb +166 -0
- data/lib/openstudio-standards/btap/bridging.rb +561 -1402
- data/lib/openstudio-standards/btap/btap.rb +4 -2
- data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
- data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
- data/lib/openstudio-standards/btap/common_paths.rb +81 -0
- data/lib/openstudio-standards/btap/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
- data/lib/openstudio-standards/btap/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/materials_hvac.csv +1686 -0
- data/lib/openstudio-standards/btap/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +469 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +173 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +354 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +215 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +156 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +15 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +27 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/btap/geometry.rb +86 -6
- data/lib/openstudio-standards/btap/structure.rb +657 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
- data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
- data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
- data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
- data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
- data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
- data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
- data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
- data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
- data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
- data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
- data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
- data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
- data/lib/openstudio-standards/hvac/components/component.rb +39 -0
- data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
- data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
- data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
- data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
- data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
- data/lib/openstudio-standards/hvac/conversions.rb +222 -0
- data/lib/openstudio-standards/hvac/curves.rb +192 -0
- data/lib/openstudio-standards/hvac/helpers.rb +357 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
- data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
- data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
- data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
- data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
- data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
- data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
- data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
- data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
- data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
- data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
- data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
- data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
- data/lib/openstudio-standards/standards/Standards.Model.rb +45 -20
- data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
- data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +7 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
- data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
- data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +21 -37
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +115 -112
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +637 -249
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +75 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +25 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +18 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +68 -150
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +444 -134
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +17 -8
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +206 -32
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +75 -43
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
- data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards/weather/stat_file.rb +2 -2
- data/lib/openstudio-standards.rb +67 -38
- metadata +141 -50
- data/lib/openstudio-standards/hvac/components/create.rb +0 -169
- data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
- data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
|
@@ -3,7 +3,7 @@
|
|
|
3
3
|
"unitary_acs": {
|
|
4
4
|
"data_type": "table",
|
|
5
5
|
"refs": [
|
|
6
|
-
"
|
|
6
|
+
"NECB 2015p1"
|
|
7
7
|
],
|
|
8
8
|
"table": [
|
|
9
9
|
{
|
|
@@ -26,7 +26,7 @@
|
|
|
26
26
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
27
27
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
28
28
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
29
|
-
"notes": "From NECB
|
|
29
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
30
30
|
},
|
|
31
31
|
{
|
|
32
32
|
"equipment_type": "Air Conditioners",
|
|
@@ -48,7 +48,7 @@
|
|
|
48
48
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
49
49
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
50
50
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
51
|
-
"notes": "From NECB
|
|
51
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
52
52
|
},
|
|
53
53
|
{
|
|
54
54
|
"equipment_type": "Air Conditioners",
|
|
@@ -70,7 +70,7 @@
|
|
|
70
70
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
71
71
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
72
72
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
73
|
-
"notes": "From NECB
|
|
73
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
74
74
|
},
|
|
75
75
|
{
|
|
76
76
|
"equipment_type": "Air Conditioners",
|
|
@@ -92,14 +92,14 @@
|
|
|
92
92
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
93
93
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
94
94
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
95
|
-
"notes": "From NECB
|
|
95
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
96
96
|
},
|
|
97
97
|
{
|
|
98
98
|
"equipment_type": "Air Conditioners",
|
|
99
99
|
"cooling_type": "AirCooled",
|
|
100
100
|
"heating_type": "Electric Resistance or None",
|
|
101
101
|
"subcategory": "Single Package",
|
|
102
|
-
"minimum_capacity":
|
|
102
|
+
"minimum_capacity": 65000.0,
|
|
103
103
|
"maximum_capacity": 136480.0,
|
|
104
104
|
"start_date": "9/9/1919",
|
|
105
105
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -114,14 +114,14 @@
|
|
|
114
114
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
115
115
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
116
116
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
117
|
-
"notes": "From NECB
|
|
117
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
118
118
|
},
|
|
119
119
|
{
|
|
120
120
|
"equipment_type": "Air Conditioners",
|
|
121
121
|
"cooling_type": "AirCooled",
|
|
122
122
|
"heating_type": "All Other",
|
|
123
123
|
"subcategory": "Single Package",
|
|
124
|
-
"minimum_capacity":
|
|
124
|
+
"minimum_capacity": 65000.0,
|
|
125
125
|
"maximum_capacity": 136480.0,
|
|
126
126
|
"start_date": "9/9/1919",
|
|
127
127
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -136,14 +136,14 @@
|
|
|
136
136
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
137
137
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
138
138
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
139
|
-
"notes": "From NECB
|
|
139
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
140
140
|
},
|
|
141
141
|
{
|
|
142
142
|
"equipment_type": "Air Conditioners",
|
|
143
143
|
"cooling_type": "AirCooled",
|
|
144
144
|
"heating_type": "Electric Resistance or None",
|
|
145
145
|
"subcategory": "Split System",
|
|
146
|
-
"minimum_capacity":
|
|
146
|
+
"minimum_capacity": 65000.0,
|
|
147
147
|
"maximum_capacity": 136480.0,
|
|
148
148
|
"start_date": "9/9/1919",
|
|
149
149
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -158,14 +158,14 @@
|
|
|
158
158
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
159
159
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
160
160
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
161
|
-
"notes": "From NECB
|
|
161
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
162
162
|
},
|
|
163
163
|
{
|
|
164
164
|
"equipment_type": "Air Conditioners",
|
|
165
165
|
"cooling_type": "AirCooled",
|
|
166
166
|
"heating_type": "All Other",
|
|
167
167
|
"subcategory": "Split System",
|
|
168
|
-
"minimum_capacity":
|
|
168
|
+
"minimum_capacity": 65000.0,
|
|
169
169
|
"maximum_capacity": 136480.0,
|
|
170
170
|
"start_date": "9/9/1919",
|
|
171
171
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -180,14 +180,14 @@
|
|
|
180
180
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
181
181
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
182
182
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
183
|
-
"notes": "From NECB
|
|
183
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
184
184
|
},
|
|
185
185
|
{
|
|
186
186
|
"equipment_type": "Air Conditioners",
|
|
187
187
|
"cooling_type": "AirCooled",
|
|
188
188
|
"heating_type": "Electric Resistance or None",
|
|
189
189
|
"subcategory": "Single Package",
|
|
190
|
-
"minimum_capacity":
|
|
190
|
+
"minimum_capacity": 136480.0,
|
|
191
191
|
"maximum_capacity": 238840.0,
|
|
192
192
|
"start_date": "9/9/1919",
|
|
193
193
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -202,14 +202,14 @@
|
|
|
202
202
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
203
203
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
204
204
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
205
|
-
"notes": "From NECB
|
|
205
|
+
"notes": "From NECB 2015, Table 5.2.12.1: CHECK THIS"
|
|
206
206
|
},
|
|
207
207
|
{
|
|
208
208
|
"equipment_type": "Air Conditioners",
|
|
209
209
|
"cooling_type": "AirCooled",
|
|
210
210
|
"heating_type": "All Other",
|
|
211
211
|
"subcategory": "Single Package",
|
|
212
|
-
"minimum_capacity":
|
|
212
|
+
"minimum_capacity": 136480.0,
|
|
213
213
|
"maximum_capacity": 238840.0,
|
|
214
214
|
"start_date": "9/9/1919",
|
|
215
215
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -224,14 +224,14 @@
|
|
|
224
224
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
225
225
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
226
226
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
227
|
-
"notes": "From NECB
|
|
227
|
+
"notes": "From NECB 2015, Table 5.2.12.1: CHECK THIS"
|
|
228
228
|
},
|
|
229
229
|
{
|
|
230
230
|
"equipment_type": "Air Conditioners",
|
|
231
231
|
"cooling_type": "AirCooled",
|
|
232
232
|
"heating_type": "Electric Resistance or None",
|
|
233
233
|
"subcategory": "Split System",
|
|
234
|
-
"minimum_capacity":
|
|
234
|
+
"minimum_capacity": 136480.0,
|
|
235
235
|
"maximum_capacity": 238840.0,
|
|
236
236
|
"start_date": "9/9/1919",
|
|
237
237
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -246,14 +246,14 @@
|
|
|
246
246
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
247
247
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
248
248
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
249
|
-
"notes": "From NECB
|
|
249
|
+
"notes": "From NECB 2015, Table 5.2.12.1: CHECK THIS"
|
|
250
250
|
},
|
|
251
251
|
{
|
|
252
252
|
"equipment_type": "Air Conditioners",
|
|
253
253
|
"cooling_type": "AirCooled",
|
|
254
254
|
"heating_type": "All Other",
|
|
255
255
|
"subcategory": "Split System",
|
|
256
|
-
"minimum_capacity":
|
|
256
|
+
"minimum_capacity": 136480.0,
|
|
257
257
|
"maximum_capacity": 238840.0,
|
|
258
258
|
"start_date": "9/9/1919",
|
|
259
259
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -268,14 +268,14 @@
|
|
|
268
268
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
269
269
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
270
270
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
271
|
-
"notes": "From NECB
|
|
271
|
+
"notes": "From NECB 2015, Table 5.2.12.1: CHECK THIS"
|
|
272
272
|
},
|
|
273
273
|
{
|
|
274
274
|
"equipment_type": "Air Conditioners",
|
|
275
275
|
"cooling_type": "AirCooled",
|
|
276
276
|
"heating_type": "Electric Resistance or None",
|
|
277
277
|
"subcategory": "Single Package",
|
|
278
|
-
"minimum_capacity":
|
|
278
|
+
"minimum_capacity": 238840.0,
|
|
279
279
|
"maximum_capacity": 759999.0,
|
|
280
280
|
"start_date": "9/9/1919",
|
|
281
281
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -290,14 +290,14 @@
|
|
|
290
290
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
291
291
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
292
292
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
293
|
-
"notes": "From NECB
|
|
293
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
294
294
|
},
|
|
295
295
|
{
|
|
296
296
|
"equipment_type": "Air Conditioners",
|
|
297
297
|
"cooling_type": "AirCooled",
|
|
298
298
|
"heating_type": "All Other",
|
|
299
299
|
"subcategory": "Single Package",
|
|
300
|
-
"minimum_capacity":
|
|
300
|
+
"minimum_capacity": 238840.0,
|
|
301
301
|
"maximum_capacity": 759999.0,
|
|
302
302
|
"start_date": "9/9/1919",
|
|
303
303
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -312,14 +312,14 @@
|
|
|
312
312
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
313
313
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
314
314
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
315
|
-
"notes": "From NECB
|
|
315
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
316
316
|
},
|
|
317
317
|
{
|
|
318
318
|
"equipment_type": "Air Conditioners",
|
|
319
319
|
"cooling_type": "AirCooled",
|
|
320
320
|
"heating_type": "Electric Resistance or None",
|
|
321
321
|
"subcategory": "Split System",
|
|
322
|
-
"minimum_capacity":
|
|
322
|
+
"minimum_capacity": 238840.0,
|
|
323
323
|
"maximum_capacity": 759999.0,
|
|
324
324
|
"start_date": "9/9/1919",
|
|
325
325
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -334,7 +334,7 @@
|
|
|
334
334
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
335
335
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
336
336
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
337
|
-
"notes": "From NECB
|
|
337
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
338
338
|
},
|
|
339
339
|
{
|
|
340
340
|
"equipment_type": "Air Conditioners",
|
|
@@ -356,14 +356,14 @@
|
|
|
356
356
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
357
357
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
358
358
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
359
|
-
"notes": "From NECB
|
|
359
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
360
360
|
},
|
|
361
361
|
{
|
|
362
362
|
"equipment_type": "Air Conditioners",
|
|
363
363
|
"cooling_type": "AirCooled",
|
|
364
364
|
"heating_type": "Electric Resistance or None",
|
|
365
365
|
"subcategory": "Single Package",
|
|
366
|
-
"minimum_capacity":
|
|
366
|
+
"minimum_capacity": 759999.0,
|
|
367
367
|
"maximum_capacity": 9999999.0,
|
|
368
368
|
"start_date": "9/9/1919",
|
|
369
369
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -378,14 +378,14 @@
|
|
|
378
378
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
379
379
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
380
380
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
381
|
-
"notes": "From NECB
|
|
381
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
382
382
|
},
|
|
383
383
|
{
|
|
384
384
|
"equipment_type": "Air Conditioners",
|
|
385
385
|
"cooling_type": "AirCooled",
|
|
386
386
|
"heating_type": "All Other",
|
|
387
387
|
"subcategory": "Single Package",
|
|
388
|
-
"minimum_capacity":
|
|
388
|
+
"minimum_capacity": 759999.0,
|
|
389
389
|
"maximum_capacity": 9999999.0,
|
|
390
390
|
"start_date": "9/9/1919",
|
|
391
391
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -400,14 +400,14 @@
|
|
|
400
400
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
401
401
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
402
402
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
403
|
-
"notes": "From NECB
|
|
403
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
404
404
|
},
|
|
405
405
|
{
|
|
406
406
|
"equipment_type": "Air Conditioners",
|
|
407
407
|
"cooling_type": "AirCooled",
|
|
408
408
|
"heating_type": "Electric Resistance or None",
|
|
409
409
|
"subcategory": "Split System",
|
|
410
|
-
"minimum_capacity":
|
|
410
|
+
"minimum_capacity": 759999.0,
|
|
411
411
|
"maximum_capacity": 9999999.0,
|
|
412
412
|
"start_date": "9/9/1919",
|
|
413
413
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -422,14 +422,14 @@
|
|
|
422
422
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
423
423
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
424
424
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
425
|
-
"notes": "From NECB
|
|
425
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
426
426
|
},
|
|
427
427
|
{
|
|
428
428
|
"equipment_type": "Air Conditioners",
|
|
429
429
|
"cooling_type": "AirCooled",
|
|
430
430
|
"heating_type": "All Other",
|
|
431
431
|
"subcategory": "Split System",
|
|
432
|
-
"minimum_capacity":
|
|
432
|
+
"minimum_capacity": 759999.0,
|
|
433
433
|
"maximum_capacity": 9999999.0,
|
|
434
434
|
"start_date": "9/9/1919",
|
|
435
435
|
"end_date": "2999-09-09T00:00:00+00:00",
|
|
@@ -444,7 +444,7 @@
|
|
|
444
444
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
445
445
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
446
446
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
447
|
-
"notes": "From NECB
|
|
447
|
+
"notes": "From NECB 2015, Table 5.2.12.1"
|
|
448
448
|
},
|
|
449
449
|
{
|
|
450
450
|
"equipment_type": "PTAC",
|
|
@@ -467,7 +467,7 @@
|
|
|
467
467
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
468
468
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
469
469
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
470
|
-
"notes": "From NECB
|
|
470
|
+
"notes": "From NECB 2015, Table 5.2.12.1 (page 5-16)"
|
|
471
471
|
},
|
|
472
472
|
{
|
|
473
473
|
"equipment_type": "PTAC",
|
|
@@ -490,7 +490,7 @@
|
|
|
490
490
|
"cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT",
|
|
491
491
|
"cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW",
|
|
492
492
|
"cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR",
|
|
493
|
-
"notes": "From NECB
|
|
493
|
+
"notes": "From NECB 2015, Table 5.2.12.1 (page 5-16)"
|
|
494
494
|
}
|
|
495
495
|
]
|
|
496
496
|
}
|
|
@@ -13,7 +13,7 @@ class NECB2015
|
|
|
13
13
|
compressor_type = search_criteria['compressor_type']
|
|
14
14
|
|
|
15
15
|
# Get the chiller capacity
|
|
16
|
-
capacity_w =
|
|
16
|
+
capacity_w = OpenstudioStandards::HVAC.chiller_electric_get_capacity(chiller_electric_eir)
|
|
17
17
|
|
|
18
18
|
# All chillers must be modulating down to 25% of their capacity
|
|
19
19
|
chiller_electric_eir.setChillerFlowMode('LeavingSetpointModulated')
|
|
@@ -95,7 +95,7 @@ class NECB2015
|
|
|
95
95
|
cop = nil
|
|
96
96
|
if chlr_props['minimum_full_load_efficiency']
|
|
97
97
|
kw_per_ton = chlr_props['minimum_full_load_efficiency']
|
|
98
|
-
cop = kw_per_ton_to_cop(kw_per_ton)
|
|
98
|
+
cop = OpenstudioStandards::HVAC.kw_per_ton_to_cop(kw_per_ton)
|
|
99
99
|
chiller_electric_eir.setReferenceCOP(cop)
|
|
100
100
|
else
|
|
101
101
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.ChillerElectricEIR', "For #{chiller_electric_eir.name}, cannot find minimum full load efficiency, will not be set.")
|
|
@@ -104,14 +104,23 @@ class NECB2015
|
|
|
104
104
|
|
|
105
105
|
# Set cooling tower properties now that the new COP of the chiller is set
|
|
106
106
|
if chiller_electric_eir.name.to_s.include? 'Primary Chiller'
|
|
107
|
-
#
|
|
107
|
+
# Get the cooling tower based on the condenser water loop rather than assume that there is only one cooling tower loop.
|
|
108
|
+
clg_towers = []
|
|
108
109
|
tower_cap = capacity_w * (1.0 + 1.0 / chiller_electric_eir.referenceCOP)
|
|
110
|
+
condenser_loop = chiller_electric_eir.condenserWaterLoop.get
|
|
111
|
+
condenser_loop.supplyComponents.each do |supply_comp|
|
|
112
|
+
if supply_comp.to_CoolingTowerSingleSpeed.is_initialized
|
|
113
|
+
clg_towers << supply_comp.to_CoolingTowerSingleSpeed.get
|
|
114
|
+
end
|
|
115
|
+
end
|
|
116
|
+
# Single speed tower model assumes 25% extra for compressor power
|
|
109
117
|
if (tower_cap / 1000.0) < 1750
|
|
110
|
-
|
|
118
|
+
clg_towers[0].setNumberofCells(1)
|
|
111
119
|
else
|
|
112
|
-
|
|
120
|
+
clg_towers[0].setNumberofCells((tower_cap / (1000 * 1750) + 0.5).round)
|
|
113
121
|
end
|
|
114
|
-
|
|
122
|
+
# Only apply cooling tower fan power if power is greater than 13kW. This is to avoid EnergyPlus issues with some small cooling towers.
|
|
123
|
+
clg_towers[0].setFanPoweratDesignAirFlowRate(0.013 * tower_cap) if (tower_cap * 0.013 > 13000.0)
|
|
115
124
|
end
|
|
116
125
|
|
|
117
126
|
# Append the name with size and kw/ton
|
|
@@ -138,7 +147,7 @@ class NECB2015
|
|
|
138
147
|
max_total_loop_pump_power_table = @standards_data['max_total_loop_pump_power']
|
|
139
148
|
plantloop.supplyComponents.each do |supplycomp|
|
|
140
149
|
case supplycomp.iddObjectType.valueName.to_s
|
|
141
|
-
when 'OS_CentralHeatPumpSystem', 'OS_Coil_Heating_WaterToAirHeatPump_EquationFit', 'OS_Coil_Heating_WaterToAirHeatPump_VariableSpeedEquationFit',
|
|
150
|
+
when 'OS_CentralHeatPumpSystem', 'OS_Coil_Heating_WaterToAirHeatPump_EquationFit', 'OS_Coil_Heating_WaterToAirHeatPump_VariableSpeedEquationFit',
|
|
142
151
|
'OS_Coil_Heating_WaterToAirHeatPump_VariableSpeedEquationFit_SpeedData', 'OS_HeatPump_PlantLoop_EIR_Heating', 'OS_HeatPump_PlantLoop_EIR_Cooling'
|
|
143
152
|
search_hash = { 'hydronic_system_type' => 'WSHP' }
|
|
144
153
|
max_powertoload = model_find_object(max_total_loop_pump_power_table, search_hash)['total_normalized_pump_power_wperkw']
|
|
@@ -167,7 +176,7 @@ class NECB2015
|
|
|
167
176
|
var_spd_pumps = pumps.select {|pump| pump.to_PumpVariableSpeed.is_initialized}
|
|
168
177
|
# EnergyPlus doesn't currently properly account for variable speed pumps operation in the condenser loop.
|
|
169
178
|
# This code is an approximation for a correction to the pump head when the loop has variable speed pumps for ground-source condenser loops.
|
|
170
|
-
# These estimates were confirmed with OS runs using Montreal weather file for offices, schoold, and apartment bldgs. Office estimates are
|
|
179
|
+
# These estimates were confirmed with OS runs using Montreal weather file for offices, schoold, and apartment bldgs. Office estimates are
|
|
171
180
|
# then for other bldg types.
|
|
172
181
|
if plantloop.name.to_s.upcase.include? "GLHX"
|
|
173
182
|
max_powertoload = 21.0
|