openstudio-standards 0.2.14 → 0.2.15.pre.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (642) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.json +0 -19
  3. data/data/geometry/ASHRAEMidriseApartment.json +47 -47
  4. data/data/geometry/ASHRAESecondarySchool.osm +2 -2
  5. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  6. data/data/standards/export_OpenStudio_libraries.rb +1 -1
  7. data/data/standards/manage_OpenStudio_Standards.rb +43 -87
  8. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
  9. data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
  10. data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
  11. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
  12. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
  13. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
  14. data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
  15. data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
  16. data/lib/openstudio-standards/btap/btap_result.rb +12 -10
  17. data/lib/openstudio-standards/btap/envelope.rb +2 -2
  18. data/lib/openstudio-standards/btap/geometry.rb +96 -49
  19. data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
  20. data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
  21. data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
  22. data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
  23. data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
  24. data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
  25. data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
  26. data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
  27. data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
  28. data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
  29. data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
  30. data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
  31. data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
  32. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
  33. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
  34. data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
  35. data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
  36. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  37. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
  38. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
  39. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
  40. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
  41. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
  42. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
  43. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
  44. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
  45. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
  46. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
  47. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
  50. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
  51. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
  52. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
  53. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
  54. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
  55. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
  56. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
  57. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
  58. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
  59. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
  60. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
  61. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
  62. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
  63. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
  64. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
  65. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
  66. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
  67. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
  68. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
  69. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
  70. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
  71. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
  72. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
  73. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
  74. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
  75. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
  76. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  77. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
  78. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
  79. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
  80. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
  81. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
  82. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
  83. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
  84. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
  85. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
  86. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
  87. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  88. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
  89. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
  90. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
  91. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
  92. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
  93. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
  99. data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
  100. data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
  101. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
  102. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
  103. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
  111. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
  112. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
  113. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
  114. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
  115. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
  116. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
  117. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
  118. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
  119. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
  120. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
  121. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
  122. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
  123. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
  124. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
  125. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
  126. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
  127. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
  128. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
  129. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
  130. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
  131. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
  132. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
  133. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
  134. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
  135. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
  136. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
  137. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
  138. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
  139. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
  140. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
  141. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
  142. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
  143. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
  144. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
  145. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
  146. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
  147. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
  148. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
  149. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
  150. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
  151. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
  152. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
  153. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
  154. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
  155. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
  156. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
  157. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
  158. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
  159. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
  160. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
  161. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
  162. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
  163. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
  164. data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
  165. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
  166. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
  167. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
  168. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
  169. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
  170. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  171. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
  172. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
  173. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
  174. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
  175. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
  176. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
  177. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
  178. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
  179. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
  180. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
  181. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
  182. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
  183. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
  184. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
  185. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
  186. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
  187. data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
  188. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
  189. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
  190. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
  191. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
  192. data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
  193. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
  194. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
  195. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
  196. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
  197. data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
  198. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
  199. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
  200. data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
  201. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
  202. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
  203. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
  204. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
  205. data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
  206. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
  207. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
  208. data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
  209. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
  210. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
  211. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
  212. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
  213. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
  214. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
  215. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
  216. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
  217. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
  218. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
  219. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
  220. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
  221. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
  222. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
  223. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
  224. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
  225. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
  226. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
  227. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
  228. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
  229. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
  230. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
  231. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
  232. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
  233. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
  234. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
  235. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
  236. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
  237. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
  238. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
  239. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
  240. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
  241. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
  242. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
  243. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
  244. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
  245. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
  246. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
  247. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
  248. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
  249. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
  250. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
  251. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
  252. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
  253. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
  254. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
  255. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
  256. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
  257. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
  258. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
  259. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
  260. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
  261. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
  262. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
  263. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  264. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
  265. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
  266. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
  267. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
  268. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
  269. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
  270. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
  271. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
  272. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
  273. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
  274. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
  275. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
  276. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
  277. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
  278. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
  279. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
  280. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
  281. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
  282. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
  283. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
  284. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
  285. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
  286. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
  287. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
  288. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
  311. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
  312. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
  313. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
  314. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
  315. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
  316. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
  317. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
  318. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
  319. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
  320. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
  321. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
  322. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
  323. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
  324. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
  325. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
  326. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
  327. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
  328. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
  329. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
  330. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
  331. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
  332. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
  333. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
  334. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
  335. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
  336. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
  337. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
  338. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
  339. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
  340. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
  341. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
  342. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
  343. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
  344. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
  345. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
  346. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
  347. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
  348. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
  349. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
  350. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
  351. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
  352. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
  353. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
  354. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
  355. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
  356. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
  357. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
  358. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
  359. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
  360. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
  361. data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
  362. data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
  363. data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
  364. data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
  365. data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
  366. data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
  367. data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
  368. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
  369. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
  370. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
  371. data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
  372. data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
  373. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
  374. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
  375. data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
  376. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
  377. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
  378. data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
  379. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
  380. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
  381. data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
  382. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
  383. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
  384. data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
  385. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
  386. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
  387. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
  388. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
  389. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
  390. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
  391. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
  392. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
  393. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
  394. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
  395. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
  396. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
  397. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
  398. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
  399. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
  400. data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
  401. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
  402. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
  403. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
  404. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
  405. data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
  406. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
  407. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
  408. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
  409. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
  410. data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
  411. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
  412. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
  413. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
  414. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
  415. data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
  416. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
  417. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
  418. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
  419. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
  420. data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
  421. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
  422. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
  423. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
  424. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
  425. data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
  426. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
  427. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
  428. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
  429. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
  430. data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
  431. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
  432. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
  433. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
  434. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
  435. data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
  436. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
  437. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
  438. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
  439. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
  440. data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
  441. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
  442. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
  443. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
  444. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
  445. data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
  446. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
  447. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
  448. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
  449. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
  450. data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
  451. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
  452. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
  453. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
  454. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
  455. data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
  456. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
  457. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
  458. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
  459. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
  460. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
  461. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
  462. data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
  463. data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
  464. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
  465. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
  466. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
  467. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
  468. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
  469. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
  470. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
  471. data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
  472. data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
  473. data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
  474. data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
  475. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
  476. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
  477. data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
  478. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
  479. data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
  480. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
  481. data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
  482. data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
  483. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
  484. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
  485. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
  486. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
  487. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
  488. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
  489. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
  490. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
  491. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
  492. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
  493. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
  494. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
  495. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
  496. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
  497. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
  498. data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
  499. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
  500. data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
  501. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
  502. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
  503. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
  504. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
  505. data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
  506. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
  507. data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
  508. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
  509. data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
  510. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
  511. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
  512. data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
  513. data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
  514. data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
  515. data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
  516. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
  517. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
  518. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
  519. data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
  520. data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
  521. data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
  522. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
  523. data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
  524. data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
  525. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
  526. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
  527. data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
  528. data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
  529. data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
  530. data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
  531. data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
  532. data/lib/openstudio-standards/standards/standard.rb +2 -1
  533. data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
  534. data/lib/openstudio-standards/utilities/logging.rb +6 -0
  535. data/lib/openstudio-standards/utilities/simulation.rb +30 -14
  536. data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
  537. data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
  538. data/lib/openstudio-standards/version.rb +2 -2
  539. data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
  540. data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
  541. data/lib/openstudio-standards.rb +9 -0
  542. metadata +106 -205
  543. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  544. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
  545. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
  546. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
  547. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
  548. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
  549. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
  550. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
  551. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
  552. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
  553. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
  554. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
  555. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
  556. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
  557. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
  558. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
  559. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
  560. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
  561. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
  562. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
  563. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
  564. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
  565. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
  566. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
  567. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
  568. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
  569. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
  570. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
  571. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
  572. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
  573. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
  574. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
  575. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
  576. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
  577. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
  578. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
  579. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
  580. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
  581. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
  582. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
  583. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
  584. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
  585. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
  586. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
  587. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
  588. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
  589. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
  590. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
  591. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
  592. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
  593. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
  594. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
  595. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
  596. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
  597. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
  598. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
  599. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
  600. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
  601. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
  602. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
  603. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
  604. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
  605. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
  606. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
  607. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
  608. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
  609. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
  610. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
  611. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
  612. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
  613. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
  614. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
  615. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
  616. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
  617. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
  618. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
  619. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
  620. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
  621. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
  622. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
  623. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
  624. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
  625. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
  626. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
  627. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
  628. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
  629. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
  630. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
  631. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
  632. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
  633. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
  634. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
  635. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
  636. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
  637. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
  638. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
  639. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
  640. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
  641. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
  642. data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
@@ -1,27 +1,27 @@
1
1
  class DOERefPre1980 < ASHRAE901
2
2
  # @!group AirLoopHVAC
3
3
 
4
- # Apply multizone vav outdoor air method and
5
- # adjust multizone VAV damper positions. Currently
6
- # doesn't do anything for the DOE prototype buildings.
4
+ # Apply multizone vav outdoor air method and adjust multizone VAV damper positions.
5
+ # Currently doesn't do anything for the DOE prototype buildings.
7
6
  #
8
- # @return [Bool] returns true if successful, false if not
7
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
8
+ # return [Bool] returns true if successful, false if not
9
9
  # @todo enable damper position adjustment for legacy IDFS
10
10
  def air_loop_hvac_apply_multizone_vav_outdoor_air_sizing(air_loop_hvac)
11
- # TODO: enable damper position adjustment for legacy IDFS
12
11
  OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', 'Damper positions not modified for DOE Ref Pre-1980 or DOE Ref 1980-2004 vintages.')
13
12
  return true
14
13
  end
15
14
 
16
- # Determine if static pressure reset is required for this
17
- # system. Not required by DOE Pre-1980.
15
+ # Determine if static pressure reset is required for this system.
16
+ # Not required by DOE Pre-1980.
18
17
  #
19
18
  # @todo Instead of requiring the input of whether a system
20
19
  # has DDC control of VAV terminals or not, determine this
21
20
  # from the system itself. This may require additional information
22
21
  # be added to the OpenStudio data model.
23
- # @param has_ddc [Bool] whether or not the system has DDC control
24
- # over VAV terminals.
22
+ #
23
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
24
+ # @param has_ddc [Bool] whether or not the system has DDC control over VAV terminals.
25
25
  # return [Bool] returns true if static pressure reset is required, false if not
26
26
  def air_loop_hvac_static_pressure_reset_required?(air_loop_hvac, has_ddc)
27
27
  sp_reset_required = false
@@ -30,14 +30,18 @@ class DOERefPre1980 < ASHRAE901
30
30
 
31
31
  # Determines if optimum start control is required.
32
32
  # Not required by DOE Pre-1980.
33
+ #
34
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
35
+ # @return [Bool] returns true if required, false if not
33
36
  def air_loop_hvac_optimum_start_required?(air_loop_hvac)
34
37
  opt_start_required = false
35
38
  return opt_start_required
36
39
  end
37
40
 
38
- # Determine whether the VAV damper control is single maximum or
39
- # dual maximum control. Single Maximum for DOE Ref Pre-1980.
41
+ # Determine whether the VAV damper control is single maximum or dual maximum control.
42
+ # Single Maximum for DOE Ref Pre-1980.
40
43
  #
44
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
41
45
  # @return [String] the damper control type: Single Maximum, Dual Maximum
42
46
  def air_loop_hvac_vav_damper_action(air_loop_hvac)
43
47
  damper_action = 'Single Maximum'
@@ -7,7 +7,7 @@ class DOERefPre1980 < ASHRAE901
7
7
  # no changes are actually made to the model.
8
8
  #
9
9
  # base infiltration rates off of.
10
- # @return [Bool] true if successful, false if not
10
+ # @return [Bool] returns true if successful, false if not
11
11
  # @todo This infiltration method is not used by the Reference
12
12
  # buildings, fix this inconsistency.
13
13
  def model_apply_infiltration_standard(model)
@@ -3,6 +3,9 @@ class DOERefPre1980 < ASHRAE901
3
3
 
4
4
  # Determine if temperature reset is required.
5
5
  # Not required for the older DOE buildings.
6
+ #
7
+ # @param plant_loop [OpenStudio::Model::PlantLoop] plant loop
8
+ # @return [Bool] returns true if required, false if not
6
9
  def plant_loop_supply_water_temperature_reset_required?(plant_loop)
7
10
  reset_required = false
8
11
  return reset_required
@@ -10,6 +10,10 @@ class DOERefPre1980 < ASHRAE901
10
10
  load_standards_database
11
11
  end
12
12
 
13
+ # Loads the openstudio standards dataset for this standard.
14
+ #
15
+ # @param data_directories [Array<String>] array of file paths that contain standards data
16
+ # @return [Hash] a hash of standards data
13
17
  def load_standards_database(data_directories = [])
14
18
  super([__dir__] + data_directories)
15
19
  end
@@ -0,0 +1,15 @@
1
+ {
2
+ "furnaces": [
3
+ {
4
+ "template": "NREL ZNE Ready 2017",
5
+ "minimum_capacity": 0.0,
6
+ "maximum_capacity": 9999999999.0,
7
+ "start_date": "1919-09-09T00:00:00+00:00",
8
+ "end_date": "2999-09-09T00:00:00+00:00",
9
+ "minimum_annual_fuel_utilization_efficiency": null,
10
+ "minimum_thermal_efficiency": 0.94,
11
+ "minimum_combustion_efficiency": null,
12
+ "notes": "Assume condensing furnace"
13
+ }
14
+ ]
15
+ }
@@ -1,8 +1,11 @@
1
1
  class NRELZNEReady2017 < ASHRAE901
2
2
  # @!group AirLoopHVAC
3
3
 
4
- # Same as 90.1-2013
5
4
  # Determine the limits for the type of economizer present on the AirLoopHVAC, if any.
5
+ # @note Same as 90.1-2013
6
+ #
7
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
8
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
6
9
  # @return [Array<Double>] [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
7
10
  def air_loop_hvac_economizer_limits(air_loop_hvac, climate_zone)
8
11
  drybulb_limit_f = nil
@@ -11,11 +14,9 @@ class NRELZNEReady2017 < ASHRAE901
11
14
 
12
15
  # Get the OA system and OA controller
13
16
  oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
14
- if oa_sys.is_initialized
15
- oa_sys = oa_sys.get
16
- else
17
- return [nil, nil, nil] # No OA system
18
- end
17
+ return [nil, nil, nil] unless oa_sys.is_initialized
18
+
19
+ oa_sys = oa_sys.get
19
20
  oa_control = oa_sys.getControllerOutdoorAir
20
21
  economizer_type = oa_control.getEconomizerControlType
21
22
  oa_control.resetEconomizerMinimumLimitDryBulbTemperature
@@ -75,21 +76,24 @@ class NRELZNEReady2017 < ASHRAE901
75
76
  return [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
76
77
  end
77
78
 
78
- # Same as 90.1-2013
79
79
  # Determine if the system economizer must be integrated or not.
80
- # All economizers must be integrated in NREL ZNE Ready 2017
80
+ # @note same as 90.1-2013
81
+ # All economizers must be integrated in 90.1-2013
82
+ #
83
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
84
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
85
+ # @return [Bool] returns true if required, false if not
81
86
  def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
82
- integrated_economizer_required = true
83
- return integrated_economizer_required
87
+ return true
84
88
  end
85
-
86
89
  # Same as 90.1-2013
87
90
  # Check the economizer type currently specified in the ControllerOutdoorAir object on this air loop
88
91
  # is acceptable per the standard.
89
92
  #
90
- # @param (see #economizer_required?)
93
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
94
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
91
95
  # @return [Bool] Returns true if allowable, if the system has no economizer or no OA system.
92
- # Returns false if the economizer type is not allowable.
96
+ # Returns false if the economizer type is not allowable.
93
97
  def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
94
98
  # EnergyPlus economizer types
95
99
  # 'NoEconomizer'
@@ -103,11 +107,9 @@ class NRELZNEReady2017 < ASHRAE901
103
107
 
104
108
  # Get the OA system and OA controller
105
109
  oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
106
- if oa_sys.is_initialized
107
- oa_sys = oa_sys.get
108
- else
109
- return true # No OA system
110
- end
110
+ return true unless oa_sys.is_initialized
111
+
112
+ oa_sys = oa_sys.get
111
113
  oa_control = oa_sys.getControllerOutdoorAir
112
114
  economizer_type = oa_control.getEconomizerControlType
113
115
 
@@ -173,14 +175,13 @@ class NRELZNEReady2017 < ASHRAE901
173
175
  return economizer_type_allowed
174
176
  end
175
177
 
176
- # Same as 90.1-2013
177
178
  # Determine if multizone vav optimization is required.
179
+ # @note Same as 90.1-2013
178
180
  #
179
- # @param (see #economizer_required?)
180
- # @return [Bool] Returns true if required, false if not.
181
- # @todo Add exception logic for
182
- # systems with AIA healthcare ventilation requirements
183
- # dual duct systems
181
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
182
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
183
+ # @return [Bool] returns true if required, false if not
184
+ # @todo Add exception logic for systems with AIA healthcare ventilation requirements dual duct systems
184
185
  def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
185
186
  multizone_opt_required = false
186
187
 
@@ -249,7 +250,7 @@ class NRELZNEReady2017 < ASHRAE901
249
250
  return multizone_opt_required
250
251
  end
251
252
 
252
- # TODO: Not required for dual-duct systems
253
+ # @todo Not required for dual-duct systems
253
254
  # if self.isDualDuct
254
255
  # OpenStudio::logFree(OpenStudio::Info, "openstudio.standards.AirLoopHVAC", "For #{controller_oa.name}: multizone optimization is not applicable because it is a dual duct system")
255
256
  # return multizone_opt_required
@@ -262,9 +263,9 @@ class NRELZNEReady2017 < ASHRAE901
262
263
  end
263
264
 
264
265
  # Determines the OA flow rates above which an economizer is required.
265
- # Two separate rates, one for systems with an economizer and another
266
- # for systems without.
267
- # are zero for both types.
266
+ # Two separate rates, one for systems with an economizer and another for systems without.
267
+ #
268
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
268
269
  # @return [Array<Double>] [min_oa_without_economizer_cfm, min_oa_with_economizer_cfm]
269
270
  def air_loop_hvac_demand_control_ventilation_limits(air_loop_hvac)
270
271
  min_oa_without_economizer_cfm = 1500.0 # half the 90.1-2013 requirement
@@ -274,14 +275,20 @@ class NRELZNEReady2017 < ASHRAE901
274
275
 
275
276
  # Determine if the standard has an exception for demand control ventilation when an energy recovery device is present.
276
277
  # DCV and an ERV may be used in conjunction.
278
+ #
279
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
280
+ # @return [Bool] returns true if required, false if not
277
281
  def air_loop_hvac_dcv_required_when_erv(air_loop_hvac)
278
282
  dcv_required_when_erv_present = true
279
283
  return dcv_required_when_erv_present
280
284
  end
281
285
 
282
- # Same as 90.1-2013
283
286
  # Determine the air flow and number of story limits for whether motorized OA damper is required.
284
- # @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]
287
+ # @note Same as 90.1-2013
288
+ #
289
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
290
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
291
+ # @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]. If both nil, never required
285
292
  def air_loop_hvac_motorized_oa_damper_limits(air_loop_hvac, climate_zone)
286
293
  case climate_zone
287
294
  when 'ASHRAE 169-2006-0A',
@@ -312,10 +319,12 @@ class NRELZNEReady2017 < ASHRAE901
312
319
  return [minimum_oa_flow_cfm, maximum_stories]
313
320
  end
314
321
 
315
- # Same as 90.1-2013
316
322
  # Determine the number of stages that should be used as controls for single zone DX systems.
323
+ # @note Same as 90.1-2013
317
324
  # 90.1-2013 depends on the cooling capacity of the system.
318
325
  #
326
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
327
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
319
328
  # @return [Integer] the number of stages: 0, 1, 2
320
329
  def air_loop_hvac_single_zone_controls_num_stages(air_loop_hvac, climate_zone)
321
330
  min_clg_cap_btu_per_hr = 65_000
@@ -331,12 +340,13 @@ class NRELZNEReady2017 < ASHRAE901
331
340
  return num_stages
332
341
  end
333
342
 
334
- # Same as 90.1-2013
335
343
  # Determine if the system required supply air temperature (SAT) reset.
344
+ # @note Same as 90.1-2013
336
345
  # For 90.1-2013, SAT reset requirements are based on climate zone.
337
346
  #
338
- # @param (see #economizer_required?)
339
- # @return [Bool] Returns true if required, false if not.
347
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
348
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
349
+ # @return [Bool] returns true if required, false if not
340
350
  def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
341
351
  is_sat_reset_required = false
342
352
 
@@ -397,6 +407,7 @@ class NRELZNEReady2017 < ASHRAE901
397
407
  end
398
408
 
399
409
  # Default occupancy fraction threshold for determining if the spaces on the air loop are occupied
410
+ # @return [Double] threshold at which the air loop space are considered unoccupied
400
411
  def air_loop_hvac_unoccupied_threshold
401
412
  return 0.05
402
413
  end
@@ -404,7 +415,9 @@ class NRELZNEReady2017 < ASHRAE901
404
415
  # Same as Standards method but with no DCV exception
405
416
  # Check if ERV is required on this airloop.
406
417
  #
407
- # @return [Bool] Returns true if required, false if not.
418
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
419
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
420
+ # @return [Bool] Returns true if required, false if not
408
421
  def air_loop_hvac_energy_recovery_ventilator_required?(air_loop_hvac, climate_zone)
409
422
  if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
410
423
  oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
@@ -460,11 +473,14 @@ class NRELZNEReady2017 < ASHRAE901
460
473
  return erv_required
461
474
  end
462
475
 
463
- # Same as 90.1-2016
464
476
  # Determine the airflow limits that govern whether or not an ERV is required.
465
477
  # Based on climate zone and % OA, plus the number of operating hours the system has.
466
- # @return [Double] the flow rate above which an ERV is required.
467
- # if nil, ERV is never required.
478
+ # @note Same as 90.1-2016
479
+ #
480
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
481
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
482
+ # @param pct_oa [Double] percentage of outdoor air
483
+ # @return [Double] the flow rate above which an ERV is required. if nil, ERV is never required.
468
484
  def air_loop_hvac_energy_recovery_ventilator_flow_limit(air_loop_hvac, climate_zone, pct_oa)
469
485
  # Calculate the number of system operating hours
470
486
  # based on the availability schedule.
@@ -729,9 +745,13 @@ class NRELZNEReady2017 < ASHRAE901
729
745
  return erv_cfm
730
746
  end
731
747
 
732
- # Determine whether to apply an Energy Recovery Ventilator 'ERV' or a Heat Recovery Ventilator 'HRV' depending on the climate zone
748
+ # Determine whether to apply an Energy Recovery Ventilator 'ERV'
749
+ # or a Heat Recovery Ventilator 'HRV' depending on the climate zone
733
750
  # Defaults to ERV.
734
- # @return [String] the ERV type
751
+ #
752
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
753
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
754
+ # @return [String] the erv type
735
755
  def air_loop_hvac_energy_recovery_ventilator_type(air_loop_hvac, climate_zone)
736
756
  erv_type = 'ERV'
737
757
  return erv_type
@@ -739,7 +759,9 @@ class NRELZNEReady2017 < ASHRAE901
739
759
 
740
760
  # Determine whether to use a Plate-Frame or Rotary Wheel style ERV depending on air loop outdoor air flow rate
741
761
  # Defaults to Rotary.
742
- # @return [String] the ERV type
762
+ #
763
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
764
+ # @return [String] the erv type
743
765
  def air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type(air_loop_hvac)
744
766
  # Get the OA system
745
767
  if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
@@ -778,7 +800,7 @@ class NRELZNEReady2017 < ASHRAE901
778
800
  # @param erv [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] erv to apply efficiency values
779
801
  # @param erv_type [String] erv type ERV or HRV
780
802
  # @param heat_exchanger_type [String] heat exchanger type Rotary or Plate
781
- # @return erv [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] erv to apply efficiency values
803
+ # @return [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] erv to apply efficiency values
782
804
  def air_loop_hvac_apply_energy_recovery_ventilator_efficiency(erv, erv_type: 'ERV', heat_exchanger_type: 'Rotary')
783
805
  if heat_exchanger_type == 'Plate'
784
806
  # based on Zehnder ComfoAir
@@ -2,10 +2,11 @@ class NRELZNEReady2017 < ASHRAE901
2
2
  # @!group AirTerminalSingleDuctVAVReheat
3
3
 
4
4
  # Specifies the minimum damper position for VAV dampers.
5
- # For terminals with hot water heat and DDC, the minimum is 20%,
6
- # otherwise the minimum is 30%.
5
+ # For terminals with hot water heat and DDC, the minimum is 20%, otherwise the minimum is 30%.
7
6
  #
7
+ # @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
8
8
  # @param has_ddc [Bool] whether or not there is DDC control of the VAV terminal in question
9
+ # @return [Double] minimum damper position
9
10
  def air_terminal_single_duct_vav_reheat_minimum_damper_position(air_terminal_single_duct_vav_reheat, has_ddc = true)
10
11
  min_damper_position = nil
11
12
  case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
@@ -3,17 +3,14 @@
3
3
  module NRELZNEReady2017CoolingTower
4
4
  # @!group CoolingTower
5
5
 
6
- # Above this point, centrifugal fan cooling towers must meet the limits
7
- # of propeller or axial cooling towers instead.
8
- # 90.1 6.5.5.3 Limit on Centrifugal Fan Open Circuit Cooling Towers.
9
- # is 1,100 gallons per minute.
6
+ # Above this point, centrifugal fan cooling towers must meet the limits of propeller or axial cooling towers instead.
7
+ # @note code_sections 6.5.5.3 limit on centrifugal fan open=circuit cooling towers is 1,100 gallons per minute.
10
8
  #
11
- # @param cooling_tower [OpenStudio::Model::CoolingTowerSingleSpeed,
12
- # OpenStudio::Model::CoolingTowerTwoSpeed,
13
- # OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
9
+ # @param cooling_tower [OpenStudio::Model::StraightComponent] cooling tower object, allowable types:
10
+ # CoolingTowerSingleSpeed, CoolingTowerTwoSpeed, CoolingTowerVariableSpeed
14
11
  # @return [Double] the limit, in gallons per minute. Return nil for no limit.
15
12
  def cooling_tower_apply_minimum_power_per_flow_gpm_limit(cooling_tower)
16
- gpm_limit = 1100
13
+ gpm_limit = 1100.0
17
14
  return gpm_limit
18
15
  end
19
16
  end
@@ -5,12 +5,11 @@ class NRELZNEReady2017 < ASHRAE901
5
5
 
6
6
  # Apply the efficiency, plus Multicell heat rejection with VSD per 90.1-2013 6.5.2.2
7
7
  #
8
- # @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
8
+ # @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] variable speed cooling tower
9
+ # @return [Bool] returns true if successful, false if not
9
10
  def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
10
11
  cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
11
-
12
12
  cooling_tower_variable_speed.setCellControl('MaximalCell')
13
-
14
13
  return true
15
14
  end
16
15
  end
@@ -5,7 +5,7 @@ class NRELZNEReady2017 < ASHRAE901
5
5
  # Per 90.1-2013, table 6.5.3.2.1: the fan motor size for chiller-water
6
6
  # and evaporative cooling is 0.25 hp as of 1/1/2014 instead of 5 hp
7
7
  #
8
- # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] the fan
8
+ # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
9
9
  # @return [Double] the limit, in horsepower. Return nil for no limit by default.
10
10
  def fan_variable_volume_part_load_fan_power_limitation_hp_limit(fan_variable_volume)
11
11
  hp_limit = case fan_variable_volume_cooling_system_type(fan_variable_volume)
@@ -24,7 +24,7 @@ class NRELZNEReady2017 < ASHRAE901
24
24
  # Per 90.1-2013, table 6.5.3.2.1: the cooling capacity threshold is 75000
25
25
  # instead of 110000 as of 1/1/2014
26
26
  #
27
- # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] the fan
27
+ # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
28
28
  # @return [Double] the limit, in Btu/hr. Return nil for no limit by default.
29
29
  def fan_variable_volume_part_load_fan_power_limitation_capacity_limit(fan_variable_volume)
30
30
  cap_limit_btu_per_hr = case fan_variable_volume_cooling_system_type(fan_variable_volume)
@@ -2,7 +2,7 @@ class NRELZNEReady2017 < ASHRAE901
2
2
  # @!group HeatExchangerSensLat
3
3
 
4
4
  # Sets the minimum effectiveness of the heat exchanger
5
- def heat_exchanger_air_to_air_sensible_and_latent_apply_efficiency(heat_exchanger_air_to_air_sensible_and_latent)
5
+ def heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
6
6
  # Assumed to be sensible and latent at all flow
7
7
  heat_exchanger_type = heat_exchanger_air_to_air_sensible_and_latent.heatExchangerType
8
8
 
@@ -73,7 +73,7 @@ class NRELZNEReady2017 < ASHRAE901
73
73
  model.getEvaporativeFluidCoolerTwoSpeeds.sort.each { |obj| fluid_cooler_apply_minimum_power_per_flow(obj, equipment_type: 'Closed Cooling Tower') }
74
74
 
75
75
  # ERVs
76
- model.getHeatExchangerAirToAirSensibleAndLatents.each { |obj| heat_exchanger_air_to_air_sensible_and_latent_apply_efficiency(obj) }
76
+ model.getHeatExchangerAirToAirSensibleAndLatents.each { |obj| heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness(obj) }
77
77
 
78
78
  # Gas Heaters
79
79
  model.getCoilHeatingGass.sort.each { |obj| coil_heating_gas_apply_efficiency_and_curves(obj) }
@@ -1,7 +1,10 @@
1
1
  class NRELZNEReady2017 < ASHRAE901
2
2
  # @!group PlantLoop
3
3
 
4
- # Applies the chilled water pumping controls to the loop
4
+ # Applies the chilled water pumping controls to the loop based on Appendix G.
5
+ #
6
+ # @param plant_loop [OpenStudio::Model::PlantLoop] chilled water loop
7
+ # @return [Bool] returns true if successful, false if not
5
8
  def plant_loop_apply_prm_baseline_chilled_water_pumping_type(plant_loop)
6
9
  pri_control_type = 'VSD DP Reset'
7
10
  sec_control_type = 'VSD DP Reset'
@@ -73,15 +73,17 @@ class NRELZNEReady2017 < ASHRAE901
73
73
  return [req_top_ctrl, req_pri_ctrl, req_sec_ctrl]
74
74
  end
75
75
 
76
- # Determine the fraction controlled by each sensor and which
77
- # window each sensor should go near.
76
+ # Determine the fraction controlled by each sensor and which window each sensor should go near.
78
77
  #
79
- # @param space [OpenStudio::Model::Space] the space with the daylighting
78
+ # @param space [OpenStudio::Model::Space] space object
79
+ # @param areas [Hash] a hash of daylighted areas
80
80
  # @param sorted_windows [Hash] a hash of windows, sorted by priority
81
81
  # @param sorted_skylights [Hash] a hash of skylights, sorted by priority
82
82
  # @param req_top_ctrl [Bool] if toplighting controls are required
83
83
  # @param req_pri_ctrl [Bool] if primary sidelighting controls are required
84
84
  # @param req_sec_ctrl [Bool] if secondary sidelighting controls are required
85
+ # @return [Array] array of 4 items
86
+ # [sensor 1 fraction, sensor 2 fraction, sensor 1 window, sensor 2 window]
85
87
  def space_daylighting_fractions_and_windows(space,
86
88
  areas,
87
89
  sorted_windows,
@@ -1,6 +1,9 @@
1
1
  class NRELZNEReady2017 < ASHRAE901
2
2
  # @!group ZoneHVACComponent
3
3
 
4
+ # default fan efficiency for small zone hvac fans, in watts per cfm
5
+ #
6
+ # @return [Double] fan efficiency in watts per cfm
4
7
  def zone_hvac_component_prm_baseline_fan_efficacy
5
8
  fan_efficacy_w_per_cfm = 0.65
6
9
  return fan_efficacy_w_per_cfm
@@ -10,6 +10,10 @@ class NRELZNEReady2017 < ASHRAE901
10
10
  load_standards_database
11
11
  end
12
12
 
13
+ # Loads the openstudio standards dataset for this standard.
14
+ #
15
+ # @param data_directories [Array<String>] array of file paths that contain standards data
16
+ # @return [Hash] a hash of standards data
13
17
  def load_standards_database(data_directories = [])
14
18
  super([__dir__] + data_directories)
15
19
  end
@@ -0,0 +1,15 @@
1
+ {
2
+ "furnaces": [
3
+ {
4
+ "template": "ZE AEDG Multifamily",
5
+ "minimum_capacity": 0.0,
6
+ "maximum_capacity": 9999999999.0,
7
+ "start_date": "1919-09-09T00:00:00+00:00",
8
+ "end_date": "2999-09-09T00:00:00+00:00",
9
+ "minimum_annual_fuel_utilization_efficiency": null,
10
+ "minimum_thermal_efficiency": 0.94,
11
+ "minimum_combustion_efficiency": null,
12
+ "notes": "Assume condensing furnace"
13
+ }
14
+ ]
15
+ }