openstudio-standards 0.2.14 → 0.2.15.pre.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.json +0 -19
- data/data/geometry/ASHRAEMidriseApartment.json +47 -47
- data/data/geometry/ASHRAESecondarySchool.osm +2 -2
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/export_OpenStudio_libraries.rb +1 -1
- data/data/standards/manage_OpenStudio_Standards.rb +43 -87
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
- data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
- data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
- data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
- data/lib/openstudio-standards/btap/btap_result.rb +12 -10
- data/lib/openstudio-standards/btap/envelope.rb +2 -2
- data/lib/openstudio-standards/btap/geometry.rb +96 -49
- data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
- data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
- data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
- data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
- data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
- data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
- data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
- data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
- data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
- data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
- data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
- data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
- data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
- data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
- data/lib/openstudio-standards/standards/standard.rb +2 -1
- data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
- data/lib/openstudio-standards/utilities/logging.rb +6 -0
- data/lib/openstudio-standards/utilities/simulation.rb +30 -14
- data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
- data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
- data/lib/openstudio-standards/version.rb +2 -2
- data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
- data/lib/openstudio-standards.rb +9 -0
- metadata +106 -205
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
- data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb
CHANGED
|
@@ -1,27 +1,27 @@
|
|
|
1
1
|
class DOERefPre1980 < ASHRAE901
|
|
2
2
|
# @!group AirLoopHVAC
|
|
3
3
|
|
|
4
|
-
# Apply multizone vav outdoor air method and
|
|
5
|
-
#
|
|
6
|
-
# doesn't do anything for the DOE prototype buildings.
|
|
4
|
+
# Apply multizone vav outdoor air method and adjust multizone VAV damper positions.
|
|
5
|
+
# Currently doesn't do anything for the DOE prototype buildings.
|
|
7
6
|
#
|
|
8
|
-
# @
|
|
7
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
8
|
+
# return [Bool] returns true if successful, false if not
|
|
9
9
|
# @todo enable damper position adjustment for legacy IDFS
|
|
10
10
|
def air_loop_hvac_apply_multizone_vav_outdoor_air_sizing(air_loop_hvac)
|
|
11
|
-
# TODO: enable damper position adjustment for legacy IDFS
|
|
12
11
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', 'Damper positions not modified for DOE Ref Pre-1980 or DOE Ref 1980-2004 vintages.')
|
|
13
12
|
return true
|
|
14
13
|
end
|
|
15
14
|
|
|
16
|
-
# Determine if static pressure reset is required for this
|
|
17
|
-
#
|
|
15
|
+
# Determine if static pressure reset is required for this system.
|
|
16
|
+
# Not required by DOE Pre-1980.
|
|
18
17
|
#
|
|
19
18
|
# @todo Instead of requiring the input of whether a system
|
|
20
19
|
# has DDC control of VAV terminals or not, determine this
|
|
21
20
|
# from the system itself. This may require additional information
|
|
22
21
|
# be added to the OpenStudio data model.
|
|
23
|
-
#
|
|
24
|
-
#
|
|
22
|
+
#
|
|
23
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
24
|
+
# @param has_ddc [Bool] whether or not the system has DDC control over VAV terminals.
|
|
25
25
|
# return [Bool] returns true if static pressure reset is required, false if not
|
|
26
26
|
def air_loop_hvac_static_pressure_reset_required?(air_loop_hvac, has_ddc)
|
|
27
27
|
sp_reset_required = false
|
|
@@ -30,14 +30,18 @@ class DOERefPre1980 < ASHRAE901
|
|
|
30
30
|
|
|
31
31
|
# Determines if optimum start control is required.
|
|
32
32
|
# Not required by DOE Pre-1980.
|
|
33
|
+
#
|
|
34
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
35
|
+
# @return [Bool] returns true if required, false if not
|
|
33
36
|
def air_loop_hvac_optimum_start_required?(air_loop_hvac)
|
|
34
37
|
opt_start_required = false
|
|
35
38
|
return opt_start_required
|
|
36
39
|
end
|
|
37
40
|
|
|
38
|
-
# Determine whether the VAV damper control is single maximum or
|
|
39
|
-
#
|
|
41
|
+
# Determine whether the VAV damper control is single maximum or dual maximum control.
|
|
42
|
+
# Single Maximum for DOE Ref Pre-1980.
|
|
40
43
|
#
|
|
44
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
41
45
|
# @return [String] the damper control type: Single Maximum, Dual Maximum
|
|
42
46
|
def air_loop_hvac_vav_damper_action(air_loop_hvac)
|
|
43
47
|
damper_action = 'Single Maximum'
|
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
CHANGED
|
@@ -7,7 +7,7 @@ class DOERefPre1980 < ASHRAE901
|
|
|
7
7
|
# no changes are actually made to the model.
|
|
8
8
|
#
|
|
9
9
|
# base infiltration rates off of.
|
|
10
|
-
# @return [Bool] true if successful, false if not
|
|
10
|
+
# @return [Bool] returns true if successful, false if not
|
|
11
11
|
# @todo This infiltration method is not used by the Reference
|
|
12
12
|
# buildings, fix this inconsistency.
|
|
13
13
|
def model_apply_infiltration_standard(model)
|
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb
CHANGED
|
@@ -3,6 +3,9 @@ class DOERefPre1980 < ASHRAE901
|
|
|
3
3
|
|
|
4
4
|
# Determine if temperature reset is required.
|
|
5
5
|
# Not required for the older DOE buildings.
|
|
6
|
+
#
|
|
7
|
+
# @param plant_loop [OpenStudio::Model::PlantLoop] plant loop
|
|
8
|
+
# @return [Bool] returns true if required, false if not
|
|
6
9
|
def plant_loop_supply_water_temperature_reset_required?(plant_loop)
|
|
7
10
|
reset_required = false
|
|
8
11
|
return reset_required
|
|
@@ -10,6 +10,10 @@ class DOERefPre1980 < ASHRAE901
|
|
|
10
10
|
load_standards_database
|
|
11
11
|
end
|
|
12
12
|
|
|
13
|
+
# Loads the openstudio standards dataset for this standard.
|
|
14
|
+
#
|
|
15
|
+
# @param data_directories [Array<String>] array of file paths that contain standards data
|
|
16
|
+
# @return [Hash] a hash of standards data
|
|
13
17
|
def load_standards_database(data_directories = [])
|
|
14
18
|
super([__dir__] + data_directories)
|
|
15
19
|
end
|
|
@@ -0,0 +1,15 @@
|
|
|
1
|
+
{
|
|
2
|
+
"furnaces": [
|
|
3
|
+
{
|
|
4
|
+
"template": "NREL ZNE Ready 2017",
|
|
5
|
+
"minimum_capacity": 0.0,
|
|
6
|
+
"maximum_capacity": 9999999999.0,
|
|
7
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
|
8
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
|
9
|
+
"minimum_annual_fuel_utilization_efficiency": null,
|
|
10
|
+
"minimum_thermal_efficiency": 0.94,
|
|
11
|
+
"minimum_combustion_efficiency": null,
|
|
12
|
+
"notes": "Assume condensing furnace"
|
|
13
|
+
}
|
|
14
|
+
]
|
|
15
|
+
}
|
|
@@ -1,8 +1,11 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group AirLoopHVAC
|
|
3
3
|
|
|
4
|
-
# Same as 90.1-2013
|
|
5
4
|
# Determine the limits for the type of economizer present on the AirLoopHVAC, if any.
|
|
5
|
+
# @note Same as 90.1-2013
|
|
6
|
+
#
|
|
7
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
8
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
6
9
|
# @return [Array<Double>] [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
|
|
7
10
|
def air_loop_hvac_economizer_limits(air_loop_hvac, climate_zone)
|
|
8
11
|
drybulb_limit_f = nil
|
|
@@ -11,11 +14,9 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
11
14
|
|
|
12
15
|
# Get the OA system and OA controller
|
|
13
16
|
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
|
14
|
-
|
|
15
|
-
|
|
16
|
-
|
|
17
|
-
return [nil, nil, nil] # No OA system
|
|
18
|
-
end
|
|
17
|
+
return [nil, nil, nil] unless oa_sys.is_initialized
|
|
18
|
+
|
|
19
|
+
oa_sys = oa_sys.get
|
|
19
20
|
oa_control = oa_sys.getControllerOutdoorAir
|
|
20
21
|
economizer_type = oa_control.getEconomizerControlType
|
|
21
22
|
oa_control.resetEconomizerMinimumLimitDryBulbTemperature
|
|
@@ -75,21 +76,24 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
75
76
|
return [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
|
|
76
77
|
end
|
|
77
78
|
|
|
78
|
-
# Same as 90.1-2013
|
|
79
79
|
# Determine if the system economizer must be integrated or not.
|
|
80
|
-
#
|
|
80
|
+
# @note same as 90.1-2013
|
|
81
|
+
# All economizers must be integrated in 90.1-2013
|
|
82
|
+
#
|
|
83
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
84
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
85
|
+
# @return [Bool] returns true if required, false if not
|
|
81
86
|
def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
|
|
82
|
-
|
|
83
|
-
return integrated_economizer_required
|
|
87
|
+
return true
|
|
84
88
|
end
|
|
85
|
-
|
|
86
89
|
# Same as 90.1-2013
|
|
87
90
|
# Check the economizer type currently specified in the ControllerOutdoorAir object on this air loop
|
|
88
91
|
# is acceptable per the standard.
|
|
89
92
|
#
|
|
90
|
-
# @param
|
|
93
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
94
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
91
95
|
# @return [Bool] Returns true if allowable, if the system has no economizer or no OA system.
|
|
92
|
-
#
|
|
96
|
+
# Returns false if the economizer type is not allowable.
|
|
93
97
|
def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
|
|
94
98
|
# EnergyPlus economizer types
|
|
95
99
|
# 'NoEconomizer'
|
|
@@ -103,11 +107,9 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
103
107
|
|
|
104
108
|
# Get the OA system and OA controller
|
|
105
109
|
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
|
106
|
-
|
|
107
|
-
|
|
108
|
-
|
|
109
|
-
return true # No OA system
|
|
110
|
-
end
|
|
110
|
+
return true unless oa_sys.is_initialized
|
|
111
|
+
|
|
112
|
+
oa_sys = oa_sys.get
|
|
111
113
|
oa_control = oa_sys.getControllerOutdoorAir
|
|
112
114
|
economizer_type = oa_control.getEconomizerControlType
|
|
113
115
|
|
|
@@ -173,14 +175,13 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
173
175
|
return economizer_type_allowed
|
|
174
176
|
end
|
|
175
177
|
|
|
176
|
-
# Same as 90.1-2013
|
|
177
178
|
# Determine if multizone vav optimization is required.
|
|
179
|
+
# @note Same as 90.1-2013
|
|
178
180
|
#
|
|
179
|
-
# @param
|
|
180
|
-
# @
|
|
181
|
-
# @
|
|
182
|
-
#
|
|
183
|
-
# dual duct systems
|
|
181
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
182
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
183
|
+
# @return [Bool] returns true if required, false if not
|
|
184
|
+
# @todo Add exception logic for systems with AIA healthcare ventilation requirements dual duct systems
|
|
184
185
|
def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
|
|
185
186
|
multizone_opt_required = false
|
|
186
187
|
|
|
@@ -249,7 +250,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
249
250
|
return multizone_opt_required
|
|
250
251
|
end
|
|
251
252
|
|
|
252
|
-
#
|
|
253
|
+
# @todo Not required for dual-duct systems
|
|
253
254
|
# if self.isDualDuct
|
|
254
255
|
# OpenStudio::logFree(OpenStudio::Info, "openstudio.standards.AirLoopHVAC", "For #{controller_oa.name}: multizone optimization is not applicable because it is a dual duct system")
|
|
255
256
|
# return multizone_opt_required
|
|
@@ -262,9 +263,9 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
262
263
|
end
|
|
263
264
|
|
|
264
265
|
# Determines the OA flow rates above which an economizer is required.
|
|
265
|
-
# Two separate rates, one for systems with an economizer and another
|
|
266
|
-
#
|
|
267
|
-
#
|
|
266
|
+
# Two separate rates, one for systems with an economizer and another for systems without.
|
|
267
|
+
#
|
|
268
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
268
269
|
# @return [Array<Double>] [min_oa_without_economizer_cfm, min_oa_with_economizer_cfm]
|
|
269
270
|
def air_loop_hvac_demand_control_ventilation_limits(air_loop_hvac)
|
|
270
271
|
min_oa_without_economizer_cfm = 1500.0 # half the 90.1-2013 requirement
|
|
@@ -274,14 +275,20 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
274
275
|
|
|
275
276
|
# Determine if the standard has an exception for demand control ventilation when an energy recovery device is present.
|
|
276
277
|
# DCV and an ERV may be used in conjunction.
|
|
278
|
+
#
|
|
279
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
280
|
+
# @return [Bool] returns true if required, false if not
|
|
277
281
|
def air_loop_hvac_dcv_required_when_erv(air_loop_hvac)
|
|
278
282
|
dcv_required_when_erv_present = true
|
|
279
283
|
return dcv_required_when_erv_present
|
|
280
284
|
end
|
|
281
285
|
|
|
282
|
-
# Same as 90.1-2013
|
|
283
286
|
# Determine the air flow and number of story limits for whether motorized OA damper is required.
|
|
284
|
-
# @
|
|
287
|
+
# @note Same as 90.1-2013
|
|
288
|
+
#
|
|
289
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
290
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
291
|
+
# @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]. If both nil, never required
|
|
285
292
|
def air_loop_hvac_motorized_oa_damper_limits(air_loop_hvac, climate_zone)
|
|
286
293
|
case climate_zone
|
|
287
294
|
when 'ASHRAE 169-2006-0A',
|
|
@@ -312,10 +319,12 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
312
319
|
return [minimum_oa_flow_cfm, maximum_stories]
|
|
313
320
|
end
|
|
314
321
|
|
|
315
|
-
# Same as 90.1-2013
|
|
316
322
|
# Determine the number of stages that should be used as controls for single zone DX systems.
|
|
323
|
+
# @note Same as 90.1-2013
|
|
317
324
|
# 90.1-2013 depends on the cooling capacity of the system.
|
|
318
325
|
#
|
|
326
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
327
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
319
328
|
# @return [Integer] the number of stages: 0, 1, 2
|
|
320
329
|
def air_loop_hvac_single_zone_controls_num_stages(air_loop_hvac, climate_zone)
|
|
321
330
|
min_clg_cap_btu_per_hr = 65_000
|
|
@@ -331,12 +340,13 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
331
340
|
return num_stages
|
|
332
341
|
end
|
|
333
342
|
|
|
334
|
-
# Same as 90.1-2013
|
|
335
343
|
# Determine if the system required supply air temperature (SAT) reset.
|
|
344
|
+
# @note Same as 90.1-2013
|
|
336
345
|
# For 90.1-2013, SAT reset requirements are based on climate zone.
|
|
337
346
|
#
|
|
338
|
-
# @param
|
|
339
|
-
# @
|
|
347
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
348
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
349
|
+
# @return [Bool] returns true if required, false if not
|
|
340
350
|
def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
|
|
341
351
|
is_sat_reset_required = false
|
|
342
352
|
|
|
@@ -397,6 +407,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
397
407
|
end
|
|
398
408
|
|
|
399
409
|
# Default occupancy fraction threshold for determining if the spaces on the air loop are occupied
|
|
410
|
+
# @return [Double] threshold at which the air loop space are considered unoccupied
|
|
400
411
|
def air_loop_hvac_unoccupied_threshold
|
|
401
412
|
return 0.05
|
|
402
413
|
end
|
|
@@ -404,7 +415,9 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
404
415
|
# Same as Standards method but with no DCV exception
|
|
405
416
|
# Check if ERV is required on this airloop.
|
|
406
417
|
#
|
|
407
|
-
# @
|
|
418
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
419
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
420
|
+
# @return [Bool] Returns true if required, false if not
|
|
408
421
|
def air_loop_hvac_energy_recovery_ventilator_required?(air_loop_hvac, climate_zone)
|
|
409
422
|
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
|
410
423
|
oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
|
|
@@ -460,11 +473,14 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
460
473
|
return erv_required
|
|
461
474
|
end
|
|
462
475
|
|
|
463
|
-
# Same as 90.1-2016
|
|
464
476
|
# Determine the airflow limits that govern whether or not an ERV is required.
|
|
465
477
|
# Based on climate zone and % OA, plus the number of operating hours the system has.
|
|
466
|
-
# @
|
|
467
|
-
#
|
|
478
|
+
# @note Same as 90.1-2016
|
|
479
|
+
#
|
|
480
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
481
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
482
|
+
# @param pct_oa [Double] percentage of outdoor air
|
|
483
|
+
# @return [Double] the flow rate above which an ERV is required. if nil, ERV is never required.
|
|
468
484
|
def air_loop_hvac_energy_recovery_ventilator_flow_limit(air_loop_hvac, climate_zone, pct_oa)
|
|
469
485
|
# Calculate the number of system operating hours
|
|
470
486
|
# based on the availability schedule.
|
|
@@ -729,9 +745,13 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
729
745
|
return erv_cfm
|
|
730
746
|
end
|
|
731
747
|
|
|
732
|
-
# Determine whether to apply an Energy Recovery Ventilator 'ERV'
|
|
748
|
+
# Determine whether to apply an Energy Recovery Ventilator 'ERV'
|
|
749
|
+
# or a Heat Recovery Ventilator 'HRV' depending on the climate zone
|
|
733
750
|
# Defaults to ERV.
|
|
734
|
-
#
|
|
751
|
+
#
|
|
752
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
753
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
754
|
+
# @return [String] the erv type
|
|
735
755
|
def air_loop_hvac_energy_recovery_ventilator_type(air_loop_hvac, climate_zone)
|
|
736
756
|
erv_type = 'ERV'
|
|
737
757
|
return erv_type
|
|
@@ -739,7 +759,9 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
739
759
|
|
|
740
760
|
# Determine whether to use a Plate-Frame or Rotary Wheel style ERV depending on air loop outdoor air flow rate
|
|
741
761
|
# Defaults to Rotary.
|
|
742
|
-
#
|
|
762
|
+
#
|
|
763
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
764
|
+
# @return [String] the erv type
|
|
743
765
|
def air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type(air_loop_hvac)
|
|
744
766
|
# Get the OA system
|
|
745
767
|
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
|
@@ -778,7 +800,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
778
800
|
# @param erv [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] erv to apply efficiency values
|
|
779
801
|
# @param erv_type [String] erv type ERV or HRV
|
|
780
802
|
# @param heat_exchanger_type [String] heat exchanger type Rotary or Plate
|
|
781
|
-
# @return
|
|
803
|
+
# @return [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] erv to apply efficiency values
|
|
782
804
|
def air_loop_hvac_apply_energy_recovery_ventilator_efficiency(erv, erv_type: 'ERV', heat_exchanger_type: 'Rotary')
|
|
783
805
|
if heat_exchanger_type == 'Plate'
|
|
784
806
|
# based on Zehnder ComfoAir
|
|
@@ -2,10 +2,11 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
2
2
|
# @!group AirTerminalSingleDuctVAVReheat
|
|
3
3
|
|
|
4
4
|
# Specifies the minimum damper position for VAV dampers.
|
|
5
|
-
# For terminals with hot water heat and DDC, the minimum is 20%,
|
|
6
|
-
# otherwise the minimum is 30%.
|
|
5
|
+
# For terminals with hot water heat and DDC, the minimum is 20%, otherwise the minimum is 30%.
|
|
7
6
|
#
|
|
7
|
+
# @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
|
|
8
8
|
# @param has_ddc [Bool] whether or not there is DDC control of the VAV terminal in question
|
|
9
|
+
# @return [Double] minimum damper position
|
|
9
10
|
def air_terminal_single_duct_vav_reheat_minimum_damper_position(air_terminal_single_duct_vav_reheat, has_ddc = true)
|
|
10
11
|
min_damper_position = nil
|
|
11
12
|
case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
@@ -3,17 +3,14 @@
|
|
|
3
3
|
module NRELZNEReady2017CoolingTower
|
|
4
4
|
# @!group CoolingTower
|
|
5
5
|
|
|
6
|
-
# Above this point, centrifugal fan cooling towers must meet the limits
|
|
7
|
-
#
|
|
8
|
-
# 90.1 6.5.5.3 Limit on Centrifugal Fan Open Circuit Cooling Towers.
|
|
9
|
-
# is 1,100 gallons per minute.
|
|
6
|
+
# Above this point, centrifugal fan cooling towers must meet the limits of propeller or axial cooling towers instead.
|
|
7
|
+
# @note code_sections 6.5.5.3 limit on centrifugal fan open=circuit cooling towers is 1,100 gallons per minute.
|
|
10
8
|
#
|
|
11
|
-
# @param cooling_tower [OpenStudio::Model::
|
|
12
|
-
#
|
|
13
|
-
# OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
|
|
9
|
+
# @param cooling_tower [OpenStudio::Model::StraightComponent] cooling tower object, allowable types:
|
|
10
|
+
# CoolingTowerSingleSpeed, CoolingTowerTwoSpeed, CoolingTowerVariableSpeed
|
|
14
11
|
# @return [Double] the limit, in gallons per minute. Return nil for no limit.
|
|
15
12
|
def cooling_tower_apply_minimum_power_per_flow_gpm_limit(cooling_tower)
|
|
16
|
-
gpm_limit = 1100
|
|
13
|
+
gpm_limit = 1100.0
|
|
17
14
|
return gpm_limit
|
|
18
15
|
end
|
|
19
16
|
end
|
|
@@ -5,12 +5,11 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
5
5
|
|
|
6
6
|
# Apply the efficiency, plus Multicell heat rejection with VSD per 90.1-2013 6.5.2.2
|
|
7
7
|
#
|
|
8
|
-
# @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed]
|
|
8
|
+
# @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] variable speed cooling tower
|
|
9
|
+
# @return [Bool] returns true if successful, false if not
|
|
9
10
|
def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
|
|
10
11
|
cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
|
|
11
|
-
|
|
12
12
|
cooling_tower_variable_speed.setCellControl('MaximalCell')
|
|
13
|
-
|
|
14
13
|
return true
|
|
15
14
|
end
|
|
16
15
|
end
|
|
@@ -5,7 +5,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
5
5
|
# Per 90.1-2013, table 6.5.3.2.1: the fan motor size for chiller-water
|
|
6
6
|
# and evaporative cooling is 0.25 hp as of 1/1/2014 instead of 5 hp
|
|
7
7
|
#
|
|
8
|
-
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume]
|
|
8
|
+
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
9
9
|
# @return [Double] the limit, in horsepower. Return nil for no limit by default.
|
|
10
10
|
def fan_variable_volume_part_load_fan_power_limitation_hp_limit(fan_variable_volume)
|
|
11
11
|
hp_limit = case fan_variable_volume_cooling_system_type(fan_variable_volume)
|
|
@@ -24,7 +24,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
24
24
|
# Per 90.1-2013, table 6.5.3.2.1: the cooling capacity threshold is 75000
|
|
25
25
|
# instead of 110000 as of 1/1/2014
|
|
26
26
|
#
|
|
27
|
-
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume]
|
|
27
|
+
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
28
28
|
# @return [Double] the limit, in Btu/hr. Return nil for no limit by default.
|
|
29
29
|
def fan_variable_volume_part_load_fan_power_limitation_capacity_limit(fan_variable_volume)
|
|
30
30
|
cap_limit_btu_per_hr = case fan_variable_volume_cooling_system_type(fan_variable_volume)
|
|
@@ -2,7 +2,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
2
2
|
# @!group HeatExchangerSensLat
|
|
3
3
|
|
|
4
4
|
# Sets the minimum effectiveness of the heat exchanger
|
|
5
|
-
def
|
|
5
|
+
def heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness(heat_exchanger_air_to_air_sensible_and_latent)
|
|
6
6
|
# Assumed to be sensible and latent at all flow
|
|
7
7
|
heat_exchanger_type = heat_exchanger_air_to_air_sensible_and_latent.heatExchangerType
|
|
8
8
|
|
data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb
CHANGED
|
@@ -73,7 +73,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
73
73
|
model.getEvaporativeFluidCoolerTwoSpeeds.sort.each { |obj| fluid_cooler_apply_minimum_power_per_flow(obj, equipment_type: 'Closed Cooling Tower') }
|
|
74
74
|
|
|
75
75
|
# ERVs
|
|
76
|
-
model.getHeatExchangerAirToAirSensibleAndLatents.each { |obj|
|
|
76
|
+
model.getHeatExchangerAirToAirSensibleAndLatents.each { |obj| heat_exchanger_air_to_air_sensible_and_latent_apply_effectiveness(obj) }
|
|
77
77
|
|
|
78
78
|
# Gas Heaters
|
|
79
79
|
model.getCoilHeatingGass.sort.each { |obj| coil_heating_gas_apply_efficiency_and_curves(obj) }
|
|
@@ -1,7 +1,10 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group PlantLoop
|
|
3
3
|
|
|
4
|
-
# Applies the chilled water pumping controls to the loop
|
|
4
|
+
# Applies the chilled water pumping controls to the loop based on Appendix G.
|
|
5
|
+
#
|
|
6
|
+
# @param plant_loop [OpenStudio::Model::PlantLoop] chilled water loop
|
|
7
|
+
# @return [Bool] returns true if successful, false if not
|
|
5
8
|
def plant_loop_apply_prm_baseline_chilled_water_pumping_type(plant_loop)
|
|
6
9
|
pri_control_type = 'VSD DP Reset'
|
|
7
10
|
sec_control_type = 'VSD DP Reset'
|
data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb
CHANGED
|
@@ -73,15 +73,17 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
73
73
|
return [req_top_ctrl, req_pri_ctrl, req_sec_ctrl]
|
|
74
74
|
end
|
|
75
75
|
|
|
76
|
-
# Determine the fraction controlled by each sensor and which
|
|
77
|
-
# window each sensor should go near.
|
|
76
|
+
# Determine the fraction controlled by each sensor and which window each sensor should go near.
|
|
78
77
|
#
|
|
79
|
-
# @param space [OpenStudio::Model::Space]
|
|
78
|
+
# @param space [OpenStudio::Model::Space] space object
|
|
79
|
+
# @param areas [Hash] a hash of daylighted areas
|
|
80
80
|
# @param sorted_windows [Hash] a hash of windows, sorted by priority
|
|
81
81
|
# @param sorted_skylights [Hash] a hash of skylights, sorted by priority
|
|
82
82
|
# @param req_top_ctrl [Bool] if toplighting controls are required
|
|
83
83
|
# @param req_pri_ctrl [Bool] if primary sidelighting controls are required
|
|
84
84
|
# @param req_sec_ctrl [Bool] if secondary sidelighting controls are required
|
|
85
|
+
# @return [Array] array of 4 items
|
|
86
|
+
# [sensor 1 fraction, sensor 2 fraction, sensor 1 window, sensor 2 window]
|
|
85
87
|
def space_daylighting_fractions_and_windows(space,
|
|
86
88
|
areas,
|
|
87
89
|
sorted_windows,
|
|
@@ -1,6 +1,9 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group ZoneHVACComponent
|
|
3
3
|
|
|
4
|
+
# default fan efficiency for small zone hvac fans, in watts per cfm
|
|
5
|
+
#
|
|
6
|
+
# @return [Double] fan efficiency in watts per cfm
|
|
4
7
|
def zone_hvac_component_prm_baseline_fan_efficacy
|
|
5
8
|
fan_efficacy_w_per_cfm = 0.65
|
|
6
9
|
return fan_efficacy_w_per_cfm
|
data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb
CHANGED
|
@@ -10,6 +10,10 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
10
10
|
load_standards_database
|
|
11
11
|
end
|
|
12
12
|
|
|
13
|
+
# Loads the openstudio standards dataset for this standard.
|
|
14
|
+
#
|
|
15
|
+
# @param data_directories [Array<String>] array of file paths that contain standards data
|
|
16
|
+
# @return [Hash] a hash of standards data
|
|
13
17
|
def load_standards_database(data_directories = [])
|
|
14
18
|
super([__dir__] + data_directories)
|
|
15
19
|
end
|
|
@@ -0,0 +1,15 @@
|
|
|
1
|
+
{
|
|
2
|
+
"furnaces": [
|
|
3
|
+
{
|
|
4
|
+
"template": "ZE AEDG Multifamily",
|
|
5
|
+
"minimum_capacity": 0.0,
|
|
6
|
+
"maximum_capacity": 9999999999.0,
|
|
7
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
|
8
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
|
9
|
+
"minimum_annual_fuel_utilization_efficiency": null,
|
|
10
|
+
"minimum_thermal_efficiency": 0.94,
|
|
11
|
+
"minimum_combustion_efficiency": null,
|
|
12
|
+
"notes": "Assume condensing furnace"
|
|
13
|
+
}
|
|
14
|
+
]
|
|
15
|
+
}
|