openstudio-standards 0.2.14 → 0.2.15.pre.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (642) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.json +0 -19
  3. data/data/geometry/ASHRAEMidriseApartment.json +47 -47
  4. data/data/geometry/ASHRAESecondarySchool.osm +2 -2
  5. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  6. data/data/standards/export_OpenStudio_libraries.rb +1 -1
  7. data/data/standards/manage_OpenStudio_Standards.rb +43 -87
  8. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
  9. data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
  10. data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
  11. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
  12. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
  13. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
  14. data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
  15. data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
  16. data/lib/openstudio-standards/btap/btap_result.rb +12 -10
  17. data/lib/openstudio-standards/btap/envelope.rb +2 -2
  18. data/lib/openstudio-standards/btap/geometry.rb +96 -49
  19. data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
  20. data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
  21. data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
  22. data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
  23. data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
  24. data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
  25. data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
  26. data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
  27. data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
  28. data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
  29. data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
  30. data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
  31. data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
  32. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
  33. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
  34. data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
  35. data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
  36. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  37. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
  38. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
  39. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
  40. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
  41. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
  42. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
  43. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
  44. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
  45. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
  46. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
  47. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
  50. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
  51. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
  52. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
  53. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
  54. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
  55. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
  56. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
  57. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
  58. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
  59. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
  60. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
  61. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
  62. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
  63. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
  64. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
  65. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
  66. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
  67. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
  68. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
  69. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
  70. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
  71. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
  72. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
  73. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
  74. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
  75. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
  76. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  77. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
  78. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
  79. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
  80. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
  81. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
  82. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
  83. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
  84. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
  85. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
  86. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
  87. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  88. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
  89. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
  90. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
  91. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
  92. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
  93. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
  99. data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
  100. data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
  101. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
  102. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
  103. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
  111. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
  112. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
  113. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
  114. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
  115. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
  116. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
  117. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
  118. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
  119. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
  120. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
  121. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
  122. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
  123. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
  124. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
  125. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
  126. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
  127. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
  128. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
  129. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
  130. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
  131. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
  132. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
  133. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
  134. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
  135. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
  136. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
  137. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
  138. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
  139. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
  140. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
  141. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
  142. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
  143. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
  144. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
  145. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
  146. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
  147. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
  148. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
  149. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
  150. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
  151. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
  152. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
  153. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
  154. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
  155. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
  156. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
  157. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
  158. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
  159. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
  160. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
  161. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
  162. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
  163. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
  164. data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
  165. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
  166. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
  167. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
  168. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
  169. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
  170. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  171. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
  172. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
  173. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
  174. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
  175. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
  176. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
  177. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
  178. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
  179. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
  180. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
  181. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
  182. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
  183. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
  184. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
  185. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
  186. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
  187. data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
  188. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
  189. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
  190. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
  191. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
  192. data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
  193. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
  194. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
  195. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
  196. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
  197. data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
  198. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
  199. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
  200. data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
  201. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
  202. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
  203. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
  204. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
  205. data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
  206. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
  207. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
  208. data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
  209. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
  210. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
  211. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
  212. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
  213. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
  214. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
  215. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
  216. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
  217. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
  218. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
  219. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
  220. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
  221. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
  222. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
  223. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
  224. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
  225. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
  226. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
  227. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
  228. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
  229. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
  230. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
  231. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
  232. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
  233. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
  234. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
  235. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
  236. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
  237. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
  238. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
  239. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
  240. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
  241. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
  242. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
  243. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
  244. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
  245. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
  246. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
  247. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
  248. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
  249. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
  250. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
  251. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
  252. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
  253. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
  254. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
  255. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
  256. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
  257. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
  258. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
  259. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
  260. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
  261. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
  262. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
  263. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  264. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
  265. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
  266. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
  267. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
  268. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
  269. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
  270. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
  271. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
  272. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
  273. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
  274. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
  275. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
  276. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
  277. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
  278. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
  279. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
  280. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
  281. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
  282. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
  283. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
  284. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
  285. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
  286. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
  287. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
  288. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
  311. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
  312. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
  313. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
  314. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
  315. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
  316. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
  317. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
  318. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
  319. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
  320. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
  321. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
  322. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
  323. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
  324. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
  325. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
  326. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
  327. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
  328. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
  329. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
  330. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
  331. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
  332. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
  333. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
  334. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
  335. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
  336. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
  337. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
  338. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
  339. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
  340. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
  341. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
  342. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
  343. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
  344. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
  345. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
  346. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
  347. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
  348. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
  349. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
  350. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
  351. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
  352. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
  353. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
  354. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
  355. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
  356. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
  357. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
  358. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
  359. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
  360. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
  361. data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
  362. data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
  363. data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
  364. data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
  365. data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
  366. data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
  367. data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
  368. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
  369. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
  370. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
  371. data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
  372. data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
  373. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
  374. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
  375. data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
  376. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
  377. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
  378. data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
  379. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
  380. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
  381. data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
  382. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
  383. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
  384. data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
  385. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
  386. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
  387. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
  388. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
  389. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
  390. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
  391. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
  392. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
  393. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
  394. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
  395. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
  396. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
  397. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
  398. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
  399. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
  400. data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
  401. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
  402. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
  403. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
  404. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
  405. data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
  406. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
  407. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
  408. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
  409. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
  410. data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
  411. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
  412. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
  413. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
  414. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
  415. data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
  416. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
  417. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
  418. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
  419. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
  420. data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
  421. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
  422. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
  423. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
  424. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
  425. data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
  426. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
  427. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
  428. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
  429. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
  430. data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
  431. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
  432. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
  433. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
  434. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
  435. data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
  436. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
  437. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
  438. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
  439. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
  440. data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
  441. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
  442. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
  443. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
  444. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
  445. data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
  446. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
  447. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
  448. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
  449. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
  450. data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
  451. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
  452. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
  453. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
  454. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
  455. data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
  456. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
  457. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
  458. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
  459. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
  460. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
  461. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
  462. data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
  463. data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
  464. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
  465. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
  466. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
  467. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
  468. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
  469. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
  470. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
  471. data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
  472. data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
  473. data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
  474. data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
  475. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
  476. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
  477. data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
  478. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
  479. data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
  480. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
  481. data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
  482. data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
  483. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
  484. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
  485. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
  486. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
  487. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
  488. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
  489. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
  490. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
  491. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
  492. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
  493. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
  494. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
  495. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
  496. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
  497. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
  498. data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
  499. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
  500. data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
  501. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
  502. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
  503. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
  504. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
  505. data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
  506. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
  507. data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
  508. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
  509. data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
  510. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
  511. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
  512. data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
  513. data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
  514. data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
  515. data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
  516. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
  517. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
  518. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
  519. data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
  520. data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
  521. data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
  522. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
  523. data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
  524. data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
  525. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
  526. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
  527. data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
  528. data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
  529. data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
  530. data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
  531. data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
  532. data/lib/openstudio-standards/standards/standard.rb +2 -1
  533. data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
  534. data/lib/openstudio-standards/utilities/logging.rb +6 -0
  535. data/lib/openstudio-standards/utilities/simulation.rb +30 -14
  536. data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
  537. data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
  538. data/lib/openstudio-standards/version.rb +2 -2
  539. data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
  540. data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
  541. data/lib/openstudio-standards.rb +9 -0
  542. metadata +106 -205
  543. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  544. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
  545. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
  546. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
  547. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
  548. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
  549. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
  550. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
  551. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
  552. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
  553. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
  554. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
  555. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
  556. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
  557. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
  558. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
  559. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
  560. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
  561. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
  562. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
  563. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
  564. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
  565. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
  566. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
  567. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
  568. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
  569. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
  570. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
  571. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
  572. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
  573. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
  574. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
  575. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
  576. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
  577. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
  578. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
  579. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
  580. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
  581. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
  582. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
  583. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
  584. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
  585. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
  586. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
  587. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
  588. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
  589. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
  590. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
  591. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
  592. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
  593. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
  594. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
  595. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
  596. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
  597. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
  598. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
  599. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
  600. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
  601. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
  602. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
  603. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
  604. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
  605. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
  606. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
  607. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
  608. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
  609. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
  610. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
  611. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
  612. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
  613. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
  614. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
  615. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
  616. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
  617. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
  618. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
  619. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
  620. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
  621. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
  622. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
  623. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
  624. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
  625. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
  626. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
  627. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
  628. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
  629. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
  630. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
  631. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
  632. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
  633. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
  634. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
  635. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
  636. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
  637. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
  638. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
  639. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
  640. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
  641. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
  642. data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
@@ -2,12 +2,16 @@ class Standard
2
2
  # @!group HeatExchangerAirToAirSensibleAndLatent
3
3
 
4
4
  # Default fan efficiency assumption for the prm added fan power
5
+ #
6
+ # @return [Double] default fan efficiency
5
7
  def heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency
6
8
  default_fan_efficiency = 0.5
7
9
  return default_fan_efficiency
8
10
  end
9
11
 
10
12
  # Sets the motor power to account for the extra fan energy from the increase in fan total static pressure
13
+ #
14
+ # @return [Bool] returns true if successful, false if not
11
15
  def heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_nominal_electric_power(heat_exchanger_air_to_air_sensible_and_latent)
12
16
  # Get the nominal supply air flow rate
13
17
  supply_air_flow_m3_per_s = nil
@@ -69,9 +73,11 @@ class Standard
69
73
  return true
70
74
  end
71
75
 
72
- # Sets the minimum effectiveness of the heat exchanger per
73
- # the DOE prototype assumptions, which assume that an enthalpy wheel is used, which exceeds
74
- # the 50% effectiveness minimum actually defined by 90.1.
76
+ # Sets the minimum effectiveness of the heat exchanger per the DOE prototype assumptions,
77
+ # which assume that an enthalpy wheel is used, which exceeds the 50% effectiveness minimum actually defined by 90.1.
78
+ #
79
+ # @param heat_exchanger_air_to_air_sensible_and_latent [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] hx
80
+ # @return [Bool] returns true if successful, false if not
75
81
  def heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency(heat_exchanger_air_to_air_sensible_and_latent)
76
82
  heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100HeatingAirFlow(0.7)
77
83
  heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100HeatingAirFlow(0.6)
@@ -86,4 +92,41 @@ class Standard
86
92
 
87
93
  return true
88
94
  end
95
+
96
+ # Set sensible and latent effectiveness at 100 and 75 heating and cooling airflow;
97
+ # The values are calculated by using ERR, which is introduced in 90.1-2016 Addendum CE
98
+ #
99
+ # This function is only used for nontransient dwelling units (Mid-rise and High-rise Apartment)
100
+ # @param heat_exchanger_air_to_air_sensible_and_latent [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] heat exchanger air to air sensible and latent
101
+ # @param enthalpy_recovery_ratio [String] enthalpy recovery ratio
102
+ # @param design_conditions [String] enthalpy recovery ratio design conditions: 'heating' or 'cooling'
103
+ # @param climate_zone [String] climate zone
104
+ def heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency_enthalpy_recovery_ratio(heat_exchanger_air_to_air_sensible_and_latent, enthalpy_recovery_ratio, design_conditions, climate_zone)
105
+ # Assumed to be sensible and latent at all flow
106
+ if enthalpy_recovery_ratio.nil?
107
+ full_htg_sens_eff = 0.0
108
+ full_htg_lat_eff = 0.0
109
+ part_htg_sens_eff = 0.0
110
+ part_htg_lat_eff = 0.0
111
+ full_cool_sens_eff = 0.0
112
+ full_cool_lat_eff = 0.0
113
+ part_cool_sens_eff = 0.0
114
+ part_cool_lat_eff = 0.0
115
+ else
116
+ enthalpy_recovery_ratio = enthalpy_recovery_ratio_design_to_typical_adjustment(enthalpy_recovery_ratio, climate_zone)
117
+ full_htg_sens_eff, full_htg_lat_eff, part_htg_sens_eff, part_htg_lat_eff, full_cool_sens_eff, full_cool_lat_eff, part_cool_sens_eff, part_cool_lat_eff = heat_exchanger_air_to_air_sensible_and_latent_enthalpy_recovery_ratio_to_effectiveness(enthalpy_recovery_ratio, design_conditions)
118
+ end
119
+
120
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100HeatingAirFlow(full_htg_sens_eff)
121
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100HeatingAirFlow(full_htg_lat_eff)
122
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75HeatingAirFlow(part_htg_sens_eff)
123
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75HeatingAirFlow(part_htg_lat_eff)
124
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat100CoolingAirFlow(full_cool_sens_eff)
125
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat100CoolingAirFlow(full_cool_lat_eff)
126
+ heat_exchanger_air_to_air_sensible_and_latent.setSensibleEffectivenessat75CoolingAirFlow(part_cool_sens_eff)
127
+ heat_exchanger_air_to_air_sensible_and_latent.setLatentEffectivenessat75CoolingAirFlow(part_cool_lat_eff)
128
+
129
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.HeatExchangerSensLat', "For #{heat_exchanger_air_to_air_sensible_and_latent.name}: Set sensible and latent effectiveness calculated by using ERR.")
130
+ return true
131
+ end
89
132
  end
@@ -1,11 +1,10 @@
1
1
  class Standard
2
2
  # Add an elevator the the specified space
3
3
  #
4
- # @param space [OpenStudio::Model::Space] the space
5
- # to assign the elevators to.
4
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
5
+ # @param space [OpenStudio::Model::Space] the space that contains the elevators
6
6
  # @param number_of_elevators [Integer] the number of elevators
7
- # @param elevator_type [String] valid choices are
8
- # Traction, Hydraulic
7
+ # @param elevator_type [String] valid choices are Traction, Hydraulic
9
8
  # @param elevator_schedule [String] the name of the elevator schedule
10
9
  # @param elevator_fan_schedule [String] the name of the elevator fan schedule
11
10
  # @param elevator_lights_schedule [String] the name of the elevator lights schedule
@@ -99,11 +98,13 @@ class Standard
99
98
  return elevator_equipment
100
99
  end
101
100
 
102
- # Determines the power required by an individual elevator
103
- # of a given type. Defaults to the values used by the DOE
104
- # prototype buildings.
105
- # @param elevator_type [String] valid choices are
106
- # Traction, Hydraulic
101
+ # Determines the power required by an individual elevator of a given type.
102
+ # Defaults to the values used by the DOE prototype buildings.
103
+ #
104
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
105
+ # @param elevator_type [String] valid choices are Traction, Hydraulic
106
+ # @param building_type [String] the building type
107
+ # @return [Double] lift power in watts
107
108
  def model_elevator_lift_power(model, elevator_type, building_type)
108
109
  lift_pwr_w = 0
109
110
  if elevator_type == 'Traction'
@@ -118,19 +119,23 @@ class Standard
118
119
  return lift_pwr_w
119
120
  end
120
121
 
121
- # Determines the percentage of the elevator cab
122
- # lighting that is incandescent. The remainder
123
- # is assumed to be LED. Defaults to 70% incandescent,
124
- # representing older elevators.
122
+ # Determines the percentage of the elevator cab lighting that is incandescent.
123
+ # The remainder is assumed to be LED.
124
+ # Defaults to 70% incandescent, representing older elevators.
125
+ #
126
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
127
+ # @return [Double] incandescent lighting percentage
125
128
  def model_elevator_lighting_pct_incandescent(model)
126
129
  pct_incandescent = 0.7
127
130
  return pct_incandescent
128
131
  end
129
132
 
130
133
  # Determines the power of the elevator ventilation fan.
131
- # Defaults to 90.1-2010, which had no requirement
132
- # for ventilation fan efficiency.
133
- # @return [Double] the ventilation fan power (W)
134
+ # Defaults to 90.1-2010, which had no requirement for ventilation fan efficiency.
135
+ #
136
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
137
+ # @param vent_rate_cfm [Double] the ventilation rate in ft^3/min
138
+ # @return [Double] the ventilation fan power in watts
134
139
  def model_elevator_fan_pwr(model, vent_rate_cfm)
135
140
  vent_pwr_per_flow_w_per_cfm = 0.33
136
141
  vent_pwr_w = vent_pwr_per_flow_w_per_cfm * vent_rate_cfm
@@ -138,17 +143,17 @@ class Standard
138
143
  return vent_pwr_w
139
144
  end
140
145
 
141
- # Add elevators to the model based on the building size,
142
- # number of stories, and building type. Logic was derived
143
- # from the DOE prototype buildings.
146
+ # Add elevators to the model based on the building size, number of stories, and building type.
147
+ # Logic was derived from the DOE prototype buildings.
144
148
  #
149
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
145
150
  # @return [OpenStudio::Model::ElectricEquipment] the resulting elevator
146
151
  def model_add_elevators(model)
147
152
  # determine effective number of stories
148
153
  effective_num_stories = model_effective_num_stories(model)
149
154
 
150
155
  # determine elevator type
151
- # todo - add logic here or upstream to have some multi-story buildings without elevators (e.g. small multi-family and small hotels)
156
+ # todo add logic here or upstream to have some multi-story buildings without elevators (e.g. small multi-family and small hotels)
152
157
  if effective_num_stories[:below_grade] + effective_num_stories[:above_grade] < 2
153
158
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.prototype.elevators', 'The building only has 1 story, no elevators will be added.')
154
159
  return nil # don't add elevators
@@ -395,10 +400,10 @@ class Standard
395
400
  end
396
401
  elevator_fan_schedule = fan_sch.name.to_s
397
402
 
398
- # TODO: - currently add elevator doesn't allow me to choose the size of the elevator?
403
+ # @todo currently add elevator doesn't allow me to choose the size of the elevator?
399
404
  # ref bldg pdf has formula for motor hp based on weight, speed, counterweight fraction and mech eff (in 5.1.4)
400
405
 
401
- # TODO: - should schedules change based on traction vs. hydraulic vs. just taking what is in prototype.
406
+ # @todo should schedules change based on traction vs. hydraulic vs. just taking what is in prototype.
402
407
 
403
408
  # call add_elevator in Prototype.hvac_systems.rb to create elevator objects
404
409
  elevator = model_add_elevator(model,
@@ -1,9 +1,13 @@
1
1
  class Standard
2
2
  # Add exterior lighting to the model
3
3
  #
4
- # @param exterior_lighting_zone_number [Integer] Valid choices are
5
- # @return [Hash] the resulting exterior lights
6
- # @todo - would be nice to add argument for some building types (SmallHotel, MidriseApartment, PrimarySchool, SecondarySchool, RetailStripmall) if it has interior or exterior circulation.
4
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
5
+ # @param exterior_lighting_zone_number [Integer] exterior lighting zone number, 0-4
6
+ # @param onsite_parking_fraction [Double] onsite parking fraction, 0-1
7
+ # @param add_base_site_allowance [Bool] whether to include the base site allowance
8
+ # @param use_model_for_entries_and_canopies [Bool] use building geometry for number of entries and canopy size
9
+ # @return [Hash] a hash of OpenStudio::Model::ExteriorLights objects
10
+ # @todo would be nice to add argument for some building types (SmallHotel, MidriseApartment, PrimarySchool, SecondarySchool, RetailStripmall) if it has interior or exterior circulation.
7
11
  def model_add_typical_exterior_lights(model, exterior_lighting_zone_number, onsite_parking_fraction = 1.0, add_base_site_allowance = false, use_model_for_entries_and_canopies = false)
8
12
  exterior_lights = {}
9
13
  installed_power = 0.0
@@ -243,7 +247,7 @@ class Standard
243
247
  installed_power += power * multiplier
244
248
  end
245
249
 
246
- # TODO: - add_base_site_lighting_allowance (non landscaping tradable lighting)
250
+ # @todo - add_base_site_lighting_allowance (non landscaping tradable lighting)
247
251
  # add exterior lights for drive through windows
248
252
  if add_base_site_allowance
249
253
 
@@ -278,11 +282,14 @@ class Standard
278
282
  return exterior_lights
279
283
  end
280
284
 
281
- # get exterior lighting area's, distances, and counts
285
+ # get exterior lighting areas, distances, and counts
282
286
  #
287
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
288
+ # @param space_type_hash [Hash] hash of space types
289
+ # @param use_model_for_entries_and_canopies [Bool] use building geometry for number of entries and canopy size
283
290
  # @return [hash] hash of exterior lighting value types and building type and model specific values
284
- # @todo - add code in to determine number of entries and canopy area from model geoemtry
285
- # @todo - come up with better logic for entry widths
291
+ # @todo add code in to determine number of entries and canopy area from model geoemtry
292
+ # @todo come up with better logic for entry widths
286
293
  def model_create_exterior_lighting_area_length_count_hash(model, space_type_hash, use_model_for_entries_and_canopies)
287
294
  # populate building_type_hashes from space_type_hash
288
295
  building_type_hashes = {}
@@ -365,7 +372,7 @@ class Standard
365
372
 
366
373
  # calculate door, window, and canopy length properties for exterior lighting
367
374
  if use_model_for_entries_and_canopies
368
- # TODO: - get number of entries and canopy size from model geometry
375
+ # @todo get number of entries and canopy size from model geometry
369
376
  else
370
377
 
371
378
  # main entries
@@ -1,5 +1,12 @@
1
1
  class Standard
2
- def model_add_hvac(model, building_type, climate_zone, prototype_input, epw_file)
2
+ # Adds the prototype HVAC system to the model
3
+ #
4
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
5
+ # @param building_type [String] the building type
6
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
7
+ # @param prototype_input [Hash] hash of prototype inputs
8
+ # @return [Bool] returns true if successful, false if not
9
+ def model_add_hvac(model, building_type, climate_zone, prototype_input)
3
10
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started Adding HVAC')
4
11
 
5
12
  # Get the list of HVAC systems, as defined for each building in the Prototype.building_name files
@@ -132,9 +139,9 @@ class Standard
132
139
  # Special logic to make a heat pump loop if necessary
133
140
  heat_pump_loop = nil
134
141
  if system['heating_type'] == 'Water To Air Heat Pump'
135
- # @code_sections [90.1-2016_6.5.5.2.1]
142
+ # @note code_sections [90.1-2016_6.5.5.2.1]
136
143
  # change highrise apartment heat rejection fan (< 5hp) from single speed to two speed evaporative fluid cooler
137
- # TODO: this is temporary fix, it should be applied to all heat rejection devices smaller than 5hp.
144
+ # @todo this is temporary fix, it should be applied to all heat rejection devices smaller than 5hp.
138
145
  if system['heat_pump_loop_cooling_type'].nil?
139
146
  hp_loop_cooling_type = 'EvaporativeFluidCooler'
140
147
  else
@@ -486,8 +493,9 @@ class Standard
486
493
  return true
487
494
  end
488
495
 
489
- # Determine the typical system type given the inputs.
496
+ # Determine the typical system type given the inputs
490
497
  #
498
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
491
499
  # @param area_type [String] Valid choices are residential and nonresidential
492
500
  # @param delivery_type [String] Conditioning delivery type. Valid choices are air and hydronic
493
501
  # @param heating_source [String] Valid choices are Electricity, NaturalGas, DistrictHeating, DistrictAmbient
@@ -553,6 +561,11 @@ class Standard
553
561
 
554
562
  private
555
563
 
564
+ # returns the thermal zones served by the system
565
+ #
566
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
567
+ # @param system [Hash] hash of system inputs
568
+ # @return [Array<OpenStudio::Model::ThermalZone>] system thermal zones
556
569
  def model_get_zones_from_spaces_on_system(model, system)
557
570
  # Find all zones associated with these spaces
558
571
  thermal_zones = []
@@ -574,6 +587,11 @@ class Standard
574
587
  return thermal_zones
575
588
  end
576
589
 
590
+ # returns the thermal zone that serves as the return plenum
591
+ #
592
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
593
+ # @param system [Hash] hash of system inputs
594
+ # @return [OpenStudio::Model::ThermalZone] the return plenum thermal zone
577
595
  def model_get_return_plenum_from_system(model, system)
578
596
  # Find the zone associated with the return plenum space name
579
597
  return_plenum = nil