openstudio-standards 0.2.14 → 0.2.15.pre.rc1

Sign up to get free protection for your applications and to get access to all the features.
Files changed (642) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.json +0 -19
  3. data/data/geometry/ASHRAEMidriseApartment.json +47 -47
  4. data/data/geometry/ASHRAESecondarySchool.osm +2 -2
  5. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  6. data/data/standards/export_OpenStudio_libraries.rb +1 -1
  7. data/data/standards/manage_OpenStudio_Standards.rb +43 -87
  8. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
  9. data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
  10. data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
  11. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
  12. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
  13. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
  14. data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
  15. data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
  16. data/lib/openstudio-standards/btap/btap_result.rb +12 -10
  17. data/lib/openstudio-standards/btap/envelope.rb +2 -2
  18. data/lib/openstudio-standards/btap/geometry.rb +96 -49
  19. data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
  20. data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
  21. data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
  22. data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
  23. data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
  24. data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
  25. data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
  26. data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
  27. data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
  28. data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
  29. data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
  30. data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
  31. data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
  32. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
  33. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
  34. data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
  35. data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
  36. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  37. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
  38. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
  39. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
  40. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
  41. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
  42. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
  43. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
  44. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
  45. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
  46. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
  47. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
  50. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
  51. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
  52. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
  53. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
  54. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
  55. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
  56. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
  57. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
  58. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
  59. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
  60. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
  61. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
  62. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
  63. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
  64. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
  65. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
  66. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
  67. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
  68. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
  69. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
  70. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
  71. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
  72. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
  73. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
  74. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
  75. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
  76. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  77. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
  78. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
  79. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
  80. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
  81. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
  82. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
  83. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
  84. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
  85. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
  86. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
  87. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  88. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
  89. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
  90. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
  91. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
  92. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
  93. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
  99. data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
  100. data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
  101. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
  102. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
  103. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
  111. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
  112. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
  113. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
  114. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
  115. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
  116. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
  117. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
  118. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
  119. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
  120. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
  121. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
  122. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
  123. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
  124. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
  125. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
  126. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
  127. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
  128. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
  129. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
  130. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
  131. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
  132. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
  133. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
  134. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
  135. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
  136. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
  137. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
  138. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
  139. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
  140. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
  141. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
  142. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
  143. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
  144. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
  145. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
  146. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
  147. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
  148. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
  149. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
  150. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
  151. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
  152. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
  153. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
  154. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
  155. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
  156. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
  157. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
  158. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
  159. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
  160. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
  161. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
  162. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
  163. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
  164. data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
  165. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
  166. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
  167. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
  168. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
  169. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
  170. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  171. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
  172. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
  173. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
  174. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
  175. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
  176. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
  177. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
  178. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
  179. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
  180. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
  181. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
  182. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
  183. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
  184. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
  185. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
  186. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
  187. data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
  188. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
  189. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
  190. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
  191. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
  192. data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
  193. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
  194. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
  195. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
  196. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
  197. data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
  198. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
  199. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
  200. data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
  201. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
  202. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
  203. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
  204. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
  205. data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
  206. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
  207. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
  208. data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
  209. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
  210. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
  211. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
  212. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
  213. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
  214. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
  215. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
  216. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
  217. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
  218. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
  219. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
  220. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
  221. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
  222. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
  223. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
  224. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
  225. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
  226. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
  227. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
  228. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
  229. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
  230. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
  231. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
  232. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
  233. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
  234. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
  235. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
  236. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
  237. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
  238. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
  239. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
  240. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
  241. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
  242. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
  243. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
  244. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
  245. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
  246. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
  247. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
  248. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
  249. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
  250. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
  251. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
  252. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
  253. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
  254. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
  255. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
  256. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
  257. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
  258. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
  259. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
  260. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
  261. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
  262. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
  263. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  264. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
  265. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
  266. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
  267. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
  268. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
  269. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
  270. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
  271. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
  272. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
  273. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
  274. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
  275. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
  276. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
  277. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
  278. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
  279. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
  280. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
  281. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
  282. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
  283. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
  284. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
  285. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
  286. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
  287. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
  288. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
  311. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
  312. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
  313. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
  314. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
  315. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
  316. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
  317. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
  318. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
  319. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
  320. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
  321. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
  322. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
  323. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
  324. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
  325. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
  326. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
  327. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
  328. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
  329. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
  330. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
  331. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
  332. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
  333. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
  334. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
  335. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
  336. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
  337. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
  338. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
  339. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
  340. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
  341. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
  342. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
  343. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
  344. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
  345. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
  346. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
  347. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
  348. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
  349. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
  350. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
  351. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
  352. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
  353. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
  354. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
  355. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
  356. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
  357. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
  358. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
  359. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
  360. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
  361. data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
  362. data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
  363. data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
  364. data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
  365. data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
  366. data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
  367. data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
  368. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
  369. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
  370. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
  371. data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
  372. data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
  373. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
  374. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
  375. data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
  376. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
  377. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
  378. data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
  379. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
  380. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
  381. data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
  382. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
  383. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
  384. data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
  385. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
  386. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
  387. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
  388. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
  389. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
  390. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
  391. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
  392. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
  393. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
  394. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
  395. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
  396. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
  397. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
  398. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
  399. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
  400. data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
  401. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
  402. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
  403. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
  404. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
  405. data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
  406. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
  407. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
  408. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
  409. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
  410. data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
  411. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
  412. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
  413. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
  414. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
  415. data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
  416. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
  417. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
  418. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
  419. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
  420. data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
  421. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
  422. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
  423. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
  424. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
  425. data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
  426. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
  427. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
  428. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
  429. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
  430. data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
  431. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
  432. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
  433. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
  434. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
  435. data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
  436. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
  437. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
  438. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
  439. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
  440. data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
  441. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
  442. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
  443. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
  444. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
  445. data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
  446. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
  447. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
  448. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
  449. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
  450. data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
  451. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
  452. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
  453. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
  454. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
  455. data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
  456. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
  457. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
  458. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
  459. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
  460. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
  461. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
  462. data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
  463. data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
  464. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
  465. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
  466. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
  467. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
  468. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
  469. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
  470. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
  471. data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
  472. data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
  473. data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
  474. data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
  475. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
  476. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
  477. data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
  478. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
  479. data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
  480. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
  481. data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
  482. data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
  483. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
  484. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
  485. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
  486. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
  487. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
  488. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
  489. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
  490. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
  491. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
  492. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
  493. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
  494. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
  495. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
  496. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
  497. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
  498. data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
  499. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
  500. data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
  501. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
  502. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
  503. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
  504. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
  505. data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
  506. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
  507. data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
  508. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
  509. data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
  510. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
  511. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
  512. data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
  513. data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
  514. data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
  515. data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
  516. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
  517. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
  518. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
  519. data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
  520. data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
  521. data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
  522. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
  523. data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
  524. data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
  525. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
  526. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
  527. data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
  528. data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
  529. data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
  530. data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
  531. data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
  532. data/lib/openstudio-standards/standards/standard.rb +2 -1
  533. data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
  534. data/lib/openstudio-standards/utilities/logging.rb +6 -0
  535. data/lib/openstudio-standards/utilities/simulation.rb +30 -14
  536. data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
  537. data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
  538. data/lib/openstudio-standards/version.rb +2 -2
  539. data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
  540. data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
  541. data/lib/openstudio-standards.rb +9 -0
  542. metadata +106 -205
  543. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  544. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
  545. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
  546. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
  547. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
  548. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
  549. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
  550. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
  551. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
  552. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
  553. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
  554. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
  555. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
  556. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
  557. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
  558. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
  559. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
  560. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
  561. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
  562. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
  563. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
  564. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
  565. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
  566. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
  567. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
  568. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
  569. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
  570. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
  571. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
  572. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
  573. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
  574. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
  575. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
  576. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
  577. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
  578. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
  579. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
  580. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
  581. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
  582. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
  583. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
  584. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
  585. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
  586. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
  587. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
  588. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
  589. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
  590. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
  591. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
  592. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
  593. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
  594. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
  595. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
  596. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
  597. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
  598. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
  599. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
  600. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
  601. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
  602. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
  603. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
  604. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
  605. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
  606. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
  607. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
  608. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
  609. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
  610. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
  611. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
  612. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
  613. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
  614. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
  615. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
  616. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
  617. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
  618. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
  619. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
  620. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
  621. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
  622. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
  623. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
  624. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
  625. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
  626. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
  627. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
  628. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
  629. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
  630. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
  631. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
  632. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
  633. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
  634. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
  635. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
  636. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
  637. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
  638. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
  639. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
  640. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
  641. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
  642. data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
@@ -1,28 +1,10 @@
1
1
  class ASHRAE9012019 < ASHRAE901
2
2
  # @!group AirLoopHVAC
3
3
 
4
- # Apply multizone vav outdoor air method and
5
- # adjust multizone VAV damper positions
6
- # to achieve a system minimum ventilation effectiveness
7
- # of 0.6 per PNNL. Hard-size the resulting min OA
8
- # into the sizing:system object.
9
- #
10
- # return [Bool] returns true if successful, false if not
11
- # @todo move building-type-specific code to Prototype classes
12
- def air_loop_hvac_apply_multizone_vav_outdoor_air_sizing(air_loop_hvac)
13
- # First time adjustment:
14
- # Only applies to multi-zone vav systems
15
- # exclusion: for Outpatient: (1) both AHU1 and AHU2 in 'DOE Ref Pre-1980' and 'DOE Ref 1980-2004'
16
- # (2) AHU1 in 2004-2019
17
- # TODO refactor: move building-type-specific code to Prototype classes
18
- if air_loop_hvac_multizone_vav_system?(air_loop_hvac) && !(air_loop_hvac.name.to_s.include? 'Outpatient F1')
19
- air_loop_hvac_adjust_minimum_vav_damper_positions(air_loop_hvac)
20
- end
21
-
22
- return true
23
- end
24
-
25
4
  # Determine the limits for the type of economizer present on the AirLoopHVAC, if any.
5
+ #
6
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
7
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
26
8
  # @return [Array<Double>] [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
27
9
  def air_loop_hvac_economizer_limits(air_loop_hvac, climate_zone)
28
10
  drybulb_limit_f = nil
@@ -31,11 +13,9 @@ class ASHRAE9012019 < ASHRAE901
31
13
 
32
14
  # Get the OA system and OA controller
33
15
  oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
34
- if oa_sys.is_initialized
35
- oa_sys = oa_sys.get
36
- else
37
- return [nil, nil, nil] # No OA system
38
- end
16
+ return [nil, nil, nil] unless oa_sys.is_initialized
17
+
18
+ oa_sys = oa_sys.get
39
19
  oa_control = oa_sys.getControllerOutdoorAir
40
20
  economizer_type = oa_control.getEconomizerControlType
41
21
  oa_control.resetEconomizerMinimumLimitDryBulbTemperature
@@ -67,17 +47,21 @@ class ASHRAE9012019 < ASHRAE901
67
47
 
68
48
  # Determine if the system economizer must be integrated or not.
69
49
  # All economizers must be integrated in 90.1-2019
50
+ #
51
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
52
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
53
+ # @return [Bool] returns true if required, false if not
70
54
  def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
71
- integrated_economizer_required = true
72
- return integrated_economizer_required
55
+ return true
73
56
  end
74
57
 
75
58
  # Check the economizer type currently specified in the ControllerOutdoorAir object on this air loop
76
59
  # is acceptable per the standard.
77
60
  #
78
- # @param (see #economizer_required?)
61
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
62
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
79
63
  # @return [Bool] Returns true if allowable, if the system has no economizer or no OA system.
80
- # Returns false if the economizer type is not allowable.
64
+ # Returns false if the economizer type is not allowable.
81
65
  def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
82
66
  # EnergyPlus economizer types
83
67
  # 'NoEconomizer'
@@ -91,11 +75,9 @@ class ASHRAE9012019 < ASHRAE901
91
75
 
92
76
  # Get the OA system and OA controller
93
77
  oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
94
- if oa_sys.is_initialized
95
- oa_sys = oa_sys.get
96
- else
97
- return true # No OA system
98
- end
78
+ return true unless oa_sys.is_initialized
79
+
80
+ oa_sys = oa_sys.get
99
81
  oa_control = oa_sys.getControllerOutdoorAir
100
82
  economizer_type = oa_control.getEconomizerControlType
101
83
 
@@ -162,13 +144,12 @@ class ASHRAE9012019 < ASHRAE901
162
144
  end
163
145
 
164
146
  # Determine if multizone vav optimization is required.
147
+ # @note code_sections [90.1-2019_6.5.3.3]
165
148
  #
166
- # @code_sections [90.1-2019_6.5.3.3]
167
- # @param (see #economizer_required?)
168
- # @return [Bool] Returns true if required, false if not.
169
- # @todo Add exception logic for
170
- # systems with AIA healthcare ventilation requirements
171
- # dual duct systems
149
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
150
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
151
+ # @return [Bool] returns true if required, false if not
152
+ # @todo Add exception logic for systems with AIA healthcare ventilation requirements dual duct systems
172
153
  def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
173
154
  multizone_opt_required = false
174
155
 
@@ -231,7 +212,7 @@ class ASHRAE9012019 < ASHRAE901
231
212
  return multizone_opt_required
232
213
  end
233
214
 
234
- # TODO: Not required for dual-duct systems
215
+ # @todo Not required for dual-duct systems
235
216
  # if self.isDualDuct
236
217
  # OpenStudio::logFree(OpenStudio::Info, "openstudio.standards.AirLoopHVAC", "For #{controller_oa.name}: multizone optimization is not applicable because it is a dual duct system")
237
218
  # return multizone_opt_required
@@ -244,9 +225,9 @@ class ASHRAE9012019 < ASHRAE901
244
225
  end
245
226
 
246
227
  # Determines the OA flow rates above which an economizer is required.
247
- # Two separate rates, one for systems with an economizer and another
248
- # for systems without.
249
- # are zero for both types.
228
+ # Two separate rates, one for systems with an economizer and another for systems without.
229
+ #
230
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
250
231
  # @return [Array<Double>] [min_oa_without_economizer_cfm, min_oa_with_economizer_cfm]
251
232
  def air_loop_hvac_demand_control_ventilation_limits(air_loop_hvac)
252
233
  min_oa_without_economizer_cfm = 3000
@@ -255,7 +236,10 @@ class ASHRAE9012019 < ASHRAE901
255
236
  end
256
237
 
257
238
  # Determine the air flow and number of story limits for whether motorized OA damper is required.
258
- # @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]
239
+ #
240
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
241
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
242
+ # @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]. If both nil, never required
259
243
  def air_loop_hvac_motorized_oa_damper_limits(air_loop_hvac, climate_zone)
260
244
  case climate_zone
261
245
  when 'ASHRAE 169-2006-0A',
@@ -289,6 +273,8 @@ class ASHRAE9012019 < ASHRAE901
289
273
  # Determine the number of stages that should be used as controls for single zone DX systems.
290
274
  # 90.1-2019 depends on the cooling capacity of the system.
291
275
  #
276
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
277
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
292
278
  # @return [Integer] the number of stages: 0, 1, 2
293
279
  def air_loop_hvac_single_zone_controls_num_stages(air_loop_hvac, climate_zone)
294
280
  min_clg_cap_btu_per_hr = 65_000
@@ -305,10 +291,11 @@ class ASHRAE9012019 < ASHRAE901
305
291
  end
306
292
 
307
293
  # Determine if the system required supply air temperature (SAT) reset.
308
- # For 90.1-2019, SAT reset requirements are based on climate zone.
294
+ # For 90.1-2019, SAT reset requirements are based on climate zone. More exceptions are added for 90.1 2019 6.5.3.5
309
295
  #
310
- # @param (see #economizer_required?)
311
- # @return [Bool] Returns true if required, false if not.
296
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
297
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
298
+ # @return [Bool] returns true if required, false if not
312
299
  def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
313
300
  is_sat_reset_required = false
314
301
 
@@ -317,16 +304,61 @@ class ASHRAE9012019 < ASHRAE901
317
304
  return is_sat_reset_required
318
305
  end
319
306
 
307
+ # check if design outside air is less than 10,000cfm (5000L/s) 90.1 2019 6.5.3.5 Exception 1 and 2
308
+ design_oa_m3s = nil
309
+ if air_loop_hvac.sizingSystem.designOutdoorAirFlowRate.is_initialized
310
+ design_oa_m3s = air_loop_hvac.sizingSystem.designOutdoorAirFlowRate.get
311
+ elsif air_loop_hvac.sizingSystem.autosizedDesignOutdoorAirFlowRate.is_initialized
312
+ design_oa_m3s = air_loop_hvac.sizingSystem.autosizedDesignOutdoorAirFlowRate.get
313
+ else
314
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name} design outdoor air flow rate is not available.")
315
+ end
316
+ design_oa_cfm = OpenStudio.convert(design_oa_m3s, 'm^3/s', 'cfm').get
317
+
318
+ # check if there is erv 90.1 2019 Exceptions to 6.5.3.5 Exception 3
319
+ has_erv = air_loop_hvac_energy_recovery?(air_loop_hvac)
320
+ design_sa_m3s = air_loop_hvac_find_design_supply_air_flow_rate(air_loop_hvac)
321
+
322
+ oa_ratio = 0
323
+ if design_sa_m3s > 0
324
+ oa_ratio = design_oa_m3s / design_sa_m3s
325
+ end
326
+ has_large_oa = (oa_ratio >= 0.8)
327
+
320
328
  case climate_zone
321
329
  when 'ASHRAE 169-2006-0A',
322
330
  'ASHRAE 169-2006-1A',
323
- 'ASHRAE 169-2006-2A',
324
331
  'ASHRAE 169-2006-3A',
325
332
  'ASHRAE 169-2013-0A',
326
333
  'ASHRAE 169-2013-1A',
327
- 'ASHRAE 169-2013-2A',
328
334
  'ASHRAE 169-2013-3A'
329
- OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.4 Exception 1, the system is located in climate zone #{climate_zone}.")
335
+ if design_oa_cfm < 3000
336
+ is_sat_reset_required = false
337
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.5 Exception 1, the system is located in climate zone #{climate_zone}.")
338
+ return is_sat_reset_required
339
+ end
340
+ if has_erv && has_large_oa
341
+ is_sat_reset_required = false
342
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.5 Exception 3, the system is located in climate zone #{climate_zone}.")
343
+ return is_sat_reset_required
344
+ end
345
+ is_sat_reset_required = true
346
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is required.")
347
+ return is_sat_reset_required
348
+ when 'ASHRAE 169-2006-2A',
349
+ 'ASHRAE 169-2013-2A'
350
+ if design_oa_cfm < 10000
351
+ is_sat_reset_required = false
352
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.5 Exception 2, the system is located in climate zone #{climate_zone}.")
353
+ return is_sat_reset_required
354
+ end
355
+ if has_erv && has_large_oa
356
+ is_sat_reset_required = false
357
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.5 Exception 3, the system is located in climate zone #{climate_zone}.")
358
+ return is_sat_reset_required
359
+ end
360
+ is_sat_reset_required = true
361
+ OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is required.")
330
362
  return is_sat_reset_required
331
363
  when 'ASHRAE 169-2006-0B',
332
364
  'ASHRAE 169-2006-1B',
@@ -370,8 +402,11 @@ class ASHRAE9012019 < ASHRAE901
370
402
 
371
403
  # Determine the airflow limits that govern whether or not an ERV is required.
372
404
  # Based on climate zone and % OA, plus the number of operating hours the system has.
373
- # @return [Double] the flow rate above which an ERV is required.
374
- # if nil, ERV is never required.
405
+ #
406
+ # @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
407
+ # @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
408
+ # @param pct_oa [Double] percentage of outdoor air
409
+ # @return [Double] the flow rate above which an ERV is required. if nil, ERV is never required.
375
410
  def air_loop_hvac_energy_recovery_ventilator_flow_limit(air_loop_hvac, climate_zone, pct_oa)
376
411
  # Calculate the number of system operating hours
377
412
  # based on the availability schedule.
@@ -419,11 +454,26 @@ class ASHRAE9012019 < ASHRAE901
419
454
  erv_cfm = energy_recovery_limits['greater_than_80_percent_oa']
420
455
  end
421
456
  else
457
+ # Check if air loop serves a non-transient dwelling unit,
458
+ # currently non-transient dwelling units are residential
459
+ # spaces in the apartment prototypes
460
+ building_data = model_get_building_climate_zone_and_building_type(air_loop_hvac.model)
461
+ building_type = building_data['building_type']
462
+ nontrans_dwel = false
463
+ if building_type == 'MidriseApartment' || building_type == 'HighriseApartment'
464
+ air_loop_hvac.thermalZones.each do |zone|
465
+ next unless thermal_zone_residential?(zone)
466
+
467
+ nontrans_dwel = true
468
+ end
469
+ end
470
+
422
471
  # Table 6.5.6.1-2, above 8000 hrs
423
472
  search_criteria = {
424
473
  'template' => template,
425
474
  'climate_zone' => climate_zone,
426
- 'under_8000_hours' => false
475
+ 'under_8000_hours' => false,
476
+ 'nontransient_dwelling' => nontrans_dwel
427
477
  }
428
478
  energy_recovery_limits = model_find_object(standards_data['energy_recovery'], search_criteria)
429
479
  if energy_recovery_limits.nil?
@@ -431,7 +481,11 @@ class ASHRAE9012019 < ASHRAE901
431
481
  return nil
432
482
  end
433
483
  if pct_oa < 0.1
434
- erv_cfm = nil
484
+ if nontrans_dwel
485
+ erv_cfm = energy_recovery_limits['0_to_10_percent_oa']
486
+ else
487
+ erv_cfm = nil
488
+ end
435
489
  elsif pct_oa >= 0.1 && pct_oa < 0.2
436
490
  erv_cfm = energy_recovery_limits['10_to_20_percent_oa']
437
491
  elsif pct_oa >= 0.2 && pct_oa < 0.3
@@ -453,4 +507,236 @@ class ASHRAE9012019 < ASHRAE901
453
507
 
454
508
  return erv_cfm
455
509
  end
510
+
511
+ # Adjust minimum VAV damper positions and set minimum design
512
+ # system outdoor air flow following ASHRAE Std. 62.1-2019
513
+ #
514
+ # @param (see #economizer_required?)
515
+ # @return [Bool] Returns true if required, false if not.
516
+ # @todo Add exception logic for systems serving parking garage, warehouse, or multifamily
517
+ def air_loop_hvac_adjust_minimum_vav_damper_positions(air_loop_hvac)
518
+ # Do not apply the adjustment to some of the system in
519
+ # the hospital and outpatient which have their minimum
520
+ # damper position determined based on AIA 2001 ventilation
521
+ # requirements
522
+ if (@instvarbuilding_type == 'Hospital' && (air_loop_hvac.name.to_s.include?('VAV_ER') || air_loop_hvac.name.to_s.include?('VAV_ICU') ||
523
+ air_loop_hvac.name.to_s.include?('VAV_OR') || air_loop_hvac.name.to_s.include?('VAV_LABS') ||
524
+ air_loop_hvac.name.to_s.include?('VAV_PATRMS'))) ||
525
+ (@instvarbuilding_type == 'Outpatient' && air_loop_hvac.name.to_s.include?('Outpatient F1'))
526
+
527
+ return true
528
+ end
529
+
530
+ # Total uncorrected outdoor airflow rate
531
+ v_ou = 0.0
532
+ air_loop_hvac.thermalZones.each do |zone|
533
+ # Vou is the system uncorrected outdoor airflow:
534
+ # Zone airflow is multiplied by the zone multiplier
535
+ v_ou += thermal_zone_outdoor_airflow_rate(zone) * zone.multiplier.to_f
536
+ end
537
+
538
+ v_ou_cfm = OpenStudio.convert(v_ou, 'm^3/s', 'cfm').get
539
+
540
+ OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: v_ou = #{v_ou_cfm.round} cfm.")
541
+
542
+ # Retrieve the sum of the zone minimum primary airflow
543
+ vpz_min_sum = air_loop_hvac.autosizeSumMinimumHeatingAirFlowRates
544
+
545
+ air_loop_hvac.thermalZones.sort.each do |zone|
546
+ # Breathing zone airflow rate
547
+ v_bz = thermal_zone_outdoor_airflow_rate(zone)
548
+
549
+ # Zone air distribution, assumed 1 per PNNL
550
+ e_z = 1.0
551
+
552
+ # Zone airflow rate
553
+ v_oz = v_bz / e_z
554
+
555
+ # Primary design airflow rate
556
+ # max of heating and cooling
557
+ # design air flow rates
558
+ v_pz = 0.0
559
+ clg_dsn_flow = zone.autosizedCoolingDesignAirFlowRate
560
+ if clg_dsn_flow.is_initialized
561
+ clg_dsn_flow = clg_dsn_flow.get
562
+ if clg_dsn_flow > v_pz
563
+ v_pz = clg_dsn_flow
564
+ end
565
+ else
566
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: #{zone.name} clg_dsn_flow could not be found.")
567
+ end
568
+ htg_dsn_flow = zone.autosizedHeatingDesignAirFlowRate
569
+ if htg_dsn_flow.is_initialized
570
+ htg_dsn_flow = htg_dsn_flow.get
571
+ if htg_dsn_flow > v_pz
572
+ v_pz = htg_dsn_flow
573
+ end
574
+ else
575
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: #{zone.name} htg_dsn_flow could not be found.")
576
+ end
577
+
578
+ # Zone ventilation efficiency calculation is computed
579
+ # on a per zone basis, the zone primary airflow is
580
+ # adjusted to removed the zone multiplier
581
+ v_pz /= zone.multiplier.to_f
582
+
583
+ # Set minimum damper position
584
+ air_loop_hvac_set_minimum_damper_position(zone, [0.01, [1.5 * v_oz / v_pz, 1.0].min].max.round(3))
585
+ end
586
+
587
+ # Occupant diversity (D): Ps / sum(Pz)
588
+ # Current value is based on school prototypes
589
+ # which are assumed to have the most diversity
590
+ occ_diver_d = 0.66
591
+
592
+ # From ASHRAE Std 62.1-2019 Section 6.2.5.3
593
+ if occ_diver_d < 0.6
594
+ e_v = 0.88 * occ_diver_d + 0.22
595
+ else
596
+ e_v = 0.75
597
+ end
598
+
599
+ # Total system outdoor intake flow rate
600
+ v_ot = v_ou / e_v
601
+ v_ot_cfm = OpenStudio.convert(v_ot, 'm^3/s', 'cfm').get
602
+
603
+ # Get maximum OA fraction schedule
604
+ oa_ctrl = air_loop_hvac.airLoopHVACOutdoorAirSystem.get.getControllerOutdoorAir
605
+ max_oa_frac_sch = oa_ctrl.maximumFractionofOutdoorAirSchedule
606
+
607
+ if !max_oa_frac_sch.is_initialized
608
+ max_oa_frac_sch = OpenStudio::Model::ScheduleConstant.new(air_loop_hvac.model)
609
+ max_oa_frac_sch.setName("#{air_loop_hvac.name}_MAX_OA_FRAC")
610
+ max_oa_frac_sch.setValue(1.0)
611
+ max_oa_frac_sch_type = 'Schedule:Constant'
612
+ oa_ctrl.setMaximumFractionofOutdoorAirSchedule(max_oa_frac_sch)
613
+ else
614
+ if max_oa_frac_sch.to_ScheduleRuleset.is_initialized
615
+ max_oa_frac_sch = max_oa_frac_sch.to_ScheduleRuleset.get
616
+ max_oa_frac_sch_type = 'Schedule:Year'
617
+ elsif max_oa_frac_sch.to_ScheduleConstant.is_initialized
618
+ max_oa_frac_sch = max_oa_frac_sch.to_ScheduleConstant.get
619
+ max_oa_frac_sch_type = 'Schedule:Constant'
620
+ elsif max_oa_frac_sch.to_ScheduleCompact.is_initialized
621
+ max_oa_frac_sch = max_oa_frac_sch.to_ScheduleCompact.get
622
+ max_oa_frac_sch_type = 'Schedule:Compact'
623
+ end
624
+ end
625
+
626
+ # Add EMS to "cap" the OA calculated by the
627
+ # Controller:MechanicalVentilation object
628
+ # to the design v_ot using the maximum OA
629
+ # fraction schedule
630
+
631
+ # Add EMS sensors
632
+ # OA mass flow calculated by the Controller:MechanicalVentilation
633
+ air_loop_hvac_name_ems = "EMS_#{air_loop_hvac.name.to_s.gsub(' ', '_')}"
634
+ oa_vrp_mass_flow = OpenStudio::Model::EnergyManagementSystemSensor.new(air_loop_hvac.model, 'Air System Outdoor Air Mechanical Ventilation Requested Mass Flow Rate')
635
+ oa_vrp_mass_flow.setKeyName(air_loop_hvac.name.to_s)
636
+ oa_vrp_mass_flow.setName("#{air_loop_hvac_name_ems}_OA_VRP")
637
+ # Actual sensed OA mass flow
638
+ oa_mass_flow = OpenStudio::Model::EnergyManagementSystemSensor.new(air_loop_hvac.model, 'Air System Outdoor Air Mass Flow Rate')
639
+ oa_mass_flow.setKeyName(air_loop_hvac.name.to_s)
640
+ oa_mass_flow.setName("#{air_loop_hvac_name_ems}_OA")
641
+ # Actual sensed volumetric OA flow
642
+ oa_vol_flow = OpenStudio::Model::EnergyManagementSystemSensor.new(air_loop_hvac.model, 'System Node Standard Density Volume Flow Rate')
643
+ oa_vol_flow.setKeyName("#{air_loop_hvac.name} Mixed Air Node")
644
+ oa_vol_flow.setName("#{air_loop_hvac_name_ems}_SUPPLY_FLOW")
645
+
646
+ # Add EMS actuator
647
+ max_oa_fraction = OpenStudio::Model::EnergyManagementSystemActuator.new(max_oa_frac_sch, max_oa_frac_sch_type, 'Schedule Value')
648
+ max_oa_fraction.setName("#{air_loop_hvac_name_ems}_MAX_OA_FRAC")
649
+
650
+ # Add EMS program
651
+ max_oa_ems_prog = OpenStudio::Model::EnergyManagementSystemProgram.new(air_loop_hvac.model)
652
+ max_oa_ems_prog.setName("#{air_loop_hvac.name}_MAX_OA_FRAC")
653
+ max_oa_ems_prog_body = <<-EMS
654
+ IF #{air_loop_hvac_name_ems}_OA > #{air_loop_hvac_name_ems}_OA_VRP,
655
+ SET #{air_loop_hvac_name_ems}_MAX_OA_FRAC = NULL,
656
+ ELSE,
657
+ IF #{air_loop_hvac_name_ems}_SUPPLY_FLOW > 0,
658
+ SET #{air_loop_hvac_name_ems}_MAX_OA_FRAC = #{v_ot} / #{air_loop_hvac_name_ems}_SUPPLY_FLOW,
659
+ ELSE,
660
+ SET #{air_loop_hvac_name_ems}_MAX_OA_FRAC = NULL,
661
+ ENDIF,
662
+ ENDIF
663
+ EMS
664
+ max_oa_ems_prog.setBody(max_oa_ems_prog_body)
665
+
666
+ max_oa_ems_prog_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(air_loop_hvac.model)
667
+ max_oa_ems_prog_manager.setName("SET_#{air_loop_hvac.name.to_s.gsub(' ', '_')}_MAX_OA_FRAC")
668
+ max_oa_ems_prog_manager.setCallingPoint('InsideHVACSystemIterationLoop')
669
+ max_oa_ems_prog_manager.addProgram(max_oa_ems_prog)
670
+
671
+ # Hard-size the sizing:system
672
+ # object with the calculated min OA flow rate
673
+ sizing_system = air_loop_hvac.sizingSystem
674
+ sizing_system.setDesignOutdoorAirFlowRate(v_ot)
675
+ sizing_system.setSystemOutdoorAirMethod('ZoneSum')
676
+
677
+ return true
678
+ end
679
+
680
+ # Add occupant standby controls to air loop
681
+ # When the thermostat schedule is setup or setback
682
+ # the ventilation is shutoff. Currently this is done
683
+ # by scheduling air terminal dampers (so load can
684
+ # still be met) and cycling unitary system fans
685
+ #
686
+ # @param air_loop_hvac [OpenStudio::model::AirLoopHVAC] OpenStudio AirLoopHVAC object
687
+ # @param standby_mode_space [Array] List of all spaces required to have standby mode controls
688
+ # @return [Boolean] true if sucessful, false otherwise
689
+ def air_loop_hvac_standby_mode_occupancy_control(air_loop_hvac, standby_mode_spaces)
690
+ if air_loop_hvac_include_unitary_system?(air_loop_hvac)
691
+ unitary_system = nil
692
+ # Get unitary system
693
+ air_loop_hvac.supplyComponents.each do |comp|
694
+ if comp.to_AirLoopHVACUnitarySystem.is_initialized
695
+ unitary_system = comp.to_AirLoopHVACUnitarySystem.get
696
+ end
697
+ end
698
+ return false unless !unitary_system.nil?
699
+
700
+ # Set fan operating schedule during assumed occupant standby mode time to 0 so the fan can cycle
701
+ new_sch = model_set_schedule_value(unitary_system.supplyAirFanOperatingModeSchedule.get, '12' => 0)
702
+ unitary_system.setSupplyAirFanOperatingModeSchedule(new_sch) unless new_sch.nil?
703
+ else
704
+ # Get thermal zones associated with spaces having standby mode occupancy requirements
705
+ standby_mode_zones = []
706
+ standby_mode_spaces.sort.each do |space|
707
+ standby_mode_zones << space.thermalZone.get
708
+ end
709
+ # Schedule the MDP of terminals to a low value during occupant standby mode
710
+ # The intent is to reduce ventilation while still allowing the terminal to
711
+ # meet loads
712
+ standby_mode_zones.each do |zone|
713
+ air_terminal = zone.airLoopHVACTerminal
714
+ if air_terminal.is_initialized
715
+ air_terminal = air_terminal.get
716
+ if air_terminal.to_AirTerminalSingleDuctVAVReheat.is_initialized
717
+ air_terminal = air_terminal.to_AirTerminalSingleDuctVAVReheat.get
718
+ if air_terminal.zoneMinimumAirFlowInputMethod == 'Constant' || air_terminal.zoneMinimumAirFlowInputMethod == 'FixedFlow'
719
+ if air_terminal.zoneMinimumAirFlowInputMethod == 'FixedFlow'
720
+ mdp_org = air_terminal.fixedMinimumAirFlowRate.get / air_terminal.autosizedMaximumAirFlowRate.get
721
+ air_terminal.setFixedMinimumAirFlowRate(0)
722
+ else
723
+ mdp_org = air_terminal.constantMinimumAirFlowFraction.get
724
+ air_terminal.setConstantMinimumAirFlowFraction(0)
725
+ end
726
+ air_terminal.setZoneMinimumAirFlowInputMethod('Scheduled')
727
+ air_terminal.setMinimumAirFlowFractionSchedule(model_set_schedule_value(model_add_constant_schedule_ruleset(air_loop_hvac.model, mdp_org, name = "#{air_terminal.name} - MDP", sch_type_limit: 'Fraction'), '12' => 0.1))
728
+ elsif air_terminal.zoneMinimumAirFlowInputMethod == 'Scheduled'
729
+ air_terminal.setMinimumAirFlowFractionSchedule(model_set_schedule_value(air_terminal.minimumAirFlowFractionSchedule.get, '12' => 0.1))
730
+ else
731
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "The air terminal associated with #{zone.name} uses a zone minimum air flow input method that is currently not supported so occupant standby controls were not modeled.")
732
+ end
733
+ else
734
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.ashrae_90_1_2019.AirLoopHVAC', "The air terminal associated with #{zone.name} isn't of the SingleDuctVAVReheat type so occupant standby controls were not modeled.")
735
+ end
736
+ end
737
+ end
738
+ end
739
+
740
+ return true
741
+ end
456
742
  end
@@ -2,10 +2,11 @@ class ASHRAE9012019 < ASHRAE901
2
2
  # @!group AirTerminalSingleDuctVAVReheat
3
3
 
4
4
  # Specifies the minimum damper position for VAV dampers.
5
- # For terminals with hot water heat and DDC, the minimum is 20%,
6
- # otherwise the minimum is 30%.
5
+ # For terminals with hot water heat and DDC, the minimum is 20%, otherwise the minimum is 30%.
7
6
  #
7
+ # @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
8
8
  # @param has_ddc [Bool] whether or not there is DDC control of the VAV terminal in question
9
+ # @return [Double] minimum damper position
9
10
  def air_terminal_single_duct_vav_reheat_minimum_damper_position(air_terminal_single_duct_vav_reheat, has_ddc = false)
10
11
  min_damper_position = nil
11
12
  case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
@@ -3,17 +3,14 @@
3
3
  module ASHRAE9012019CoolingTower
4
4
  # @!group CoolingTower
5
5
 
6
- # Above this point, centrifugal fan cooling towers must meet the limits
7
- # of propeller or axial cooling towers instead.
8
- # 90.1 6.5.5.3 Limit on Centrifugal Fan Open Circuit Cooling Towers.
9
- # is 1,100 gallons per minute.
6
+ # Above this point, centrifugal fan cooling towers must meet the limits of propeller or axial cooling towers instead.
7
+ # @note code_sections 6.5.5.3 limit on centrifugal fan open=circuit cooling towers is 1,100 gallons per minute.
10
8
  #
11
- # @param cooling_tower [OpenStudio::Model::CoolingTowerSingleSpeed,
12
- # OpenStudio::Model::CoolingTowerTwoSpeed,
13
- # OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
9
+ # @param cooling_tower [OpenStudio::Model::StraightComponent] cooling tower object, allowable types:
10
+ # CoolingTowerSingleSpeed, CoolingTowerTwoSpeed, CoolingTowerVariableSpeed
14
11
  # @return [Double] the limit, in gallons per minute. Return nil for no limit.
15
12
  def cooling_tower_apply_minimum_power_per_flow_gpm_limit(cooling_tower)
16
- gpm_limit = 1100
13
+ gpm_limit = 1100.0
17
14
  return gpm_limit
18
15
  end
19
16
  end
@@ -5,12 +5,11 @@ class ASHRAE9012019 < ASHRAE901
5
5
 
6
6
  # Apply the efficiency, plus Multicell heat rejection with VSD
7
7
  #
8
- # @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
8
+ # @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] variable speed cooling tower
9
+ # @return [Bool] returns true if successful, false if not
9
10
  def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
10
11
  cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
11
-
12
12
  cooling_tower_variable_speed.setCellControl('MaximalCell')
13
-
14
13
  return true
15
14
  end
16
15
  end
@@ -5,7 +5,7 @@ class ASHRAE9012019 < ASHRAE901
5
5
  # Per 90.1-2019, table 6.5.3.2.1: the fan motor size for chiller-water
6
6
  # and evaporative cooling is 0.25 hp as of 1/1/2014 instead of 5 hp
7
7
  #
8
- # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] the fan
8
+ # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
9
9
  # @return [Double] the limit, in horsepower. Return nil for no limit by default.
10
10
  def fan_variable_volume_part_load_fan_power_limitation_hp_limit(fan_variable_volume)
11
11
  hp_limit = case fan_variable_volume_cooling_system_type(fan_variable_volume)
@@ -24,7 +24,7 @@ class ASHRAE9012019 < ASHRAE901
24
24
  # Per 90.1-2019, table 6.5.3.2.1: the cooling capacity threshold is 75000
25
25
  # instead of 110000 as of 1/1/2014
26
26
  #
27
- # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] the fan
27
+ # @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
28
28
  # @return [Double] the limit, in Btu/hr. Return nil for no limit by default.
29
29
  def fan_variable_volume_part_load_fan_power_limitation_capacity_limit(fan_variable_volume)
30
30
  cap_limit_btu_per_hr = case fan_variable_volume_cooling_system_type(fan_variable_volume)
@@ -96,15 +96,17 @@ class ASHRAE9012019 < ASHRAE901
96
96
  return [req_top_ctrl, req_pri_ctrl, req_sec_ctrl]
97
97
  end
98
98
 
99
- # Determine the fraction controlled by each sensor and which
100
- # window each sensor should go near.
99
+ # Determine the fraction controlled by each sensor and which window each sensor should go near.
101
100
  #
102
- # @param space [OpenStudio::Model::Space] the space with the daylighting
101
+ # @param space [OpenStudio::Model::Space] space object
102
+ # @param areas [Hash] a hash of daylighted areas
103
103
  # @param sorted_windows [Hash] a hash of windows, sorted by priority
104
104
  # @param sorted_skylights [Hash] a hash of skylights, sorted by priority
105
105
  # @param req_top_ctrl [Bool] if toplighting controls are required
106
106
  # @param req_pri_ctrl [Bool] if primary sidelighting controls are required
107
107
  # @param req_sec_ctrl [Bool] if secondary sidelighting controls are required
108
+ # @return [Array] array of 4 items
109
+ # [sensor 1 fraction, sensor 2 fraction, sensor 1 window, sensor 2 window]
108
110
  def space_daylighting_fractions_and_windows(space,
109
111
  areas,
110
112
  sorted_windows,
@@ -160,7 +162,8 @@ class ASHRAE9012019 < ASHRAE901
160
162
  sensor_1_window = sorted_skylights[0]
161
163
  else
162
164
  # Sensor 1 controls toplighted area
163
- sensor_1_frac = areas['toplighted_area'] / space_area_m2
165
+ num_sensors = 2
166
+ sensor_1_frac = areas['toplighted_area'] / space_area_m2 / num_sensors
164
167
  sensor_1_window = sorted_skylights[0]
165
168
  sensor_2_frac = sensor_1_frac
166
169
  sensor_2_window = sensor_1_window
@@ -178,7 +181,7 @@ class ASHRAE9012019 < ASHRAE901
178
181
  return [sensor_1_frac, sensor_2_frac, sensor_1_window, sensor_2_window]
179
182
  end
180
183
 
181
- # Determine the base infiltration rate at 75 PA.
184
+ # Determine the base infiltration rate at 75 Pa.
182
185
  #
183
186
  # @return [Double] the baseline infiltration rate, in cfm/ft^2
184
187
  # defaults to no infiltration.
@@ -186,4 +189,21 @@ class ASHRAE9012019 < ASHRAE901
186
189
  basic_infil_rate_cfm_per_ft2 = 1.0
187
190
  return basic_infil_rate_cfm_per_ft2
188
191
  end
192
+
193
+ # Provide the type of daylighting control type
194
+ #
195
+ # @param [OpenStudio::Model::Space] OpenStudio Space object
196
+ # return [String] daylighting control type
197
+ def space_daylighting_control_type(space)
198
+ return 'ContinuousOff'
199
+ end
200
+
201
+ # Provide the minimum input power fraction for continuous
202
+ # dimming daylighting control
203
+ #
204
+ # @param [OpenStudio::Model::Space] OpenStudio Space object
205
+ # return [Float] daylighting minimum input power fraction
206
+ def space_daylighting_minimum_input_power_fraction(space)
207
+ return 0.2
208
+ end
189
209
  end
@@ -24,7 +24,8 @@ class ASHRAE9012019 < ASHRAE901
24
24
  case bldg_type
25
25
  when 'Retail', 'StripMall', 'SuperMarket'
26
26
  occ_type = 'retail'
27
- # when 'SomeBuildingType' # TODO add publicassembly building types
27
+ # when 'SomeBuildingType'
28
+ # @todo add publicassembly building types
28
29
  # occ_type = 'publicassembly'
29
30
  end
30
31
  end