openstudio-standards 0.2.14 → 0.2.15.pre.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.json +0 -19
- data/data/geometry/ASHRAEMidriseApartment.json +47 -47
- data/data/geometry/ASHRAESecondarySchool.osm +2 -2
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/export_OpenStudio_libraries.rb +1 -1
- data/data/standards/manage_OpenStudio_Standards.rb +43 -87
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
- data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
- data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
- data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
- data/lib/openstudio-standards/btap/btap_result.rb +12 -10
- data/lib/openstudio-standards/btap/envelope.rb +2 -2
- data/lib/openstudio-standards/btap/geometry.rb +96 -49
- data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
- data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
- data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
- data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
- data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
- data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
- data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
- data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
- data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
- data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
- data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
- data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
- data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
- data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
- data/lib/openstudio-standards/standards/standard.rb +2 -1
- data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
- data/lib/openstudio-standards/utilities/logging.rb +6 -0
- data/lib/openstudio-standards/utilities/simulation.rb +30 -14
- data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
- data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
- data/lib/openstudio-standards/version.rb +2 -2
- data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
- data/lib/openstudio-standards.rb +9 -0
- metadata +106 -205
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
- data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
|
@@ -4,7 +4,8 @@ class DOERefPre1980 < ASHRAE901
|
|
|
4
4
|
# Zones with low OA per area get lower initial guesses.
|
|
5
5
|
# Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions
|
|
6
6
|
#
|
|
7
|
-
# @param
|
|
7
|
+
# @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
|
|
8
|
+
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
8
9
|
# @return [Bool] returns true if successful, false if not
|
|
9
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
10
11
|
# Set the minimum flow fraction
|
|
@@ -1,11 +1,12 @@
|
|
|
1
1
|
class DOERefPre1980 < ASHRAE901
|
|
2
2
|
# @!group CoilHeatingGas
|
|
3
3
|
|
|
4
|
-
# Updates the efficiency of some gas heating coils
|
|
5
|
-
# per the
|
|
6
|
-
# inside PSZ-AC systems to 78% efficiency per
|
|
7
|
-
# the older vintages.
|
|
4
|
+
# Updates the efficiency of some gas heating coils per the prototype assumptions.
|
|
5
|
+
# Sets heating coils inside PSZ-AC systems to 78% efficiency per the older vintages.
|
|
8
6
|
# @todo Refactor: remove inconsistency in logic; all coils should be lower efficiency
|
|
7
|
+
#
|
|
8
|
+
# @param coil_heating_gas [OpenStudio::Model::CoilHeatingGas] a gas heating coil
|
|
9
|
+
# @return [Bool] returns true if successful, false if not
|
|
9
10
|
def coil_heating_gas_apply_prototype_efficiency(coil_heating_gas)
|
|
10
11
|
# Only modify coils in PSZ-AC units
|
|
11
12
|
name_patterns = ['PSZ-AC Gas Htg Coil',
|
|
@@ -3,18 +3,16 @@ class DOERefPre1980 < ASHRAE901
|
|
|
3
3
|
|
|
4
4
|
# Add an elevator the the specified space
|
|
5
5
|
#
|
|
6
|
-
# @param
|
|
7
|
-
# to assign the elevators to.
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
7
|
+
# @param space [OpenStudio::Model::Space] the space to assign the elevators to.
|
|
8
8
|
# @param number_of_elevators [Integer] the number of elevators
|
|
9
|
-
# @param elevator_type [String] valid choices are
|
|
10
|
-
# Traction, Hydraulic
|
|
9
|
+
# @param elevator_type [String] valid choices are Traction, Hydraulic
|
|
11
10
|
# @param elevator_schedule [String] the name of the elevator schedule
|
|
12
11
|
# @param elevator_fan_schedule [String] the name of the elevator fan schedule
|
|
13
12
|
# @param elevator_lights_schedule [String] the name of the elevator lights schedule
|
|
14
13
|
# @param building_type [String] the building type
|
|
15
14
|
# @return [OpenStudio::Model::ElectricEquipment] the resulting elevator
|
|
16
|
-
# @todo Inconsistency. Older vintages don't have lights or fans
|
|
17
|
-
# in elevators, which is not realistic.
|
|
15
|
+
# @todo Inconsistency. Older vintages don't have lights or fans in elevators, which is not realistic.
|
|
18
16
|
def model_add_elevator(model,
|
|
19
17
|
space,
|
|
20
18
|
number_of_elevators,
|
|
@@ -75,11 +73,13 @@ class DOERefPre1980 < ASHRAE901
|
|
|
75
73
|
return elevator_equipment
|
|
76
74
|
end
|
|
77
75
|
|
|
78
|
-
# Determines the power required by an individual elevator
|
|
79
|
-
#
|
|
80
|
-
#
|
|
81
|
-
# @param
|
|
82
|
-
# Traction, Hydraulic
|
|
76
|
+
# Determines the power required by an individual elevator of a given type.
|
|
77
|
+
# Values used by the older vintages are slightly higher than those used by the DOE prototypes.
|
|
78
|
+
#
|
|
79
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
80
|
+
# @param elevator_type [String] valid choices are Traction, Hydraulic
|
|
81
|
+
# @param building_type [string] the building type
|
|
82
|
+
# @return [Double] elevator lift power in watts
|
|
83
83
|
def model_elevator_lift_power(model, elevator_type, building_type)
|
|
84
84
|
lift_pwr_w = 0
|
|
85
85
|
if elevator_type == 'Traction'
|
|
@@ -1,10 +1,11 @@
|
|
|
1
1
|
class DOERefPre1980 < ASHRAE901
|
|
2
2
|
# @!group refrigeration
|
|
3
3
|
|
|
4
|
-
# Determine the latent case credit curve to use
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determine the latent case credit curve to use for walkins.
|
|
5
|
+
# @todo Should probably use the model_add_refrigeration_walkin and lookups from the spreadsheet instead of hard-coded values.
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
8
|
+
# @return [String] curve name
|
|
8
9
|
def model_walkin_freezer_latent_case_credit_curve(model)
|
|
9
10
|
latent_case_credit_curve_name = 'Single Shelf Horizontal Latent Energy Multiplier_Pre2004'
|
|
10
11
|
return latent_case_credit_curve_name
|
|
@@ -4,7 +4,8 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
4
4
|
# Zones with low OA per area get lower initial guesses.
|
|
5
5
|
# Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions
|
|
6
6
|
#
|
|
7
|
-
# @param
|
|
7
|
+
# @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
|
|
8
|
+
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
8
9
|
# @return [Bool] returns true if successful, false if not
|
|
9
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
10
11
|
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
@@ -1,10 +1,11 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group FanConstantVolume
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for a constant volume
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for a constant volume fan on an AirLoopHVAC based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_constant_volume [OpenStudio::Model::FanConstantVolume] constant volume fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
8
9
|
def fan_constant_volume_airloop_fan_pressure_rise(fan_constant_volume)
|
|
9
10
|
# Get the max flow rate from the fan.
|
|
10
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -1,11 +1,11 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group FanOnOff
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for an on off
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
# @
|
|
8
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for an on off fan on an AirLoopHVAC or inside a unitary system based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_on_off [OpenStudio::Model::FanOnOff] on off fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
9
9
|
def fan_on_off_airloop_or_unitary_fan_pressure_rise(fan_on_off)
|
|
10
10
|
# Get the max flow rate from the fan.
|
|
11
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -1,10 +1,11 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group FanVariableVolume
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for a variable volume
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for a variable volume fan on an AirLoopHVAC based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
8
9
|
def fan_variable_volume_airloop_fan_pressure_rise(fan_variable_volume)
|
|
9
10
|
# Get the max flow rate from the fan.
|
|
10
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -2,6 +2,8 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
2
2
|
# @!group HeatExchangerAirToAirSensibleAndLatent
|
|
3
3
|
|
|
4
4
|
# Default fan efficiency assumption for the prm added fan power
|
|
5
|
+
#
|
|
6
|
+
# @return [Double] default fan efficiency
|
|
5
7
|
def heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency
|
|
6
8
|
default_fan_efficiency = 0.55
|
|
7
9
|
return default_fan_efficiency
|
|
@@ -1,19 +1,23 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group elevators
|
|
3
3
|
|
|
4
|
-
# Determines the percentage of the elevator cab
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determines the percentage of the elevator cab lighting that is incandescent.
|
|
5
|
+
# The remainder is assumed to be LED.
|
|
6
|
+
# Defaults to 0% incandescent (100% LED), representing newer elevators.
|
|
7
|
+
#
|
|
8
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
9
|
+
# @return [Double] incandescent lighting percentage
|
|
8
10
|
def model_elevator_lighting_pct_incandescent(model)
|
|
9
11
|
pct_incandescent = 0.0 # 100% LED
|
|
10
12
|
return pct_incandescent
|
|
11
13
|
end
|
|
12
14
|
|
|
13
15
|
# Determines the power of the elevator ventilation fan.
|
|
14
|
-
# Same as 90.1-2013, which has a requirement
|
|
15
|
-
#
|
|
16
|
-
# @
|
|
16
|
+
# Same as 90.1-2013, which has a requirement for ventilation fan efficiency.
|
|
17
|
+
#
|
|
18
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
19
|
+
# @param vent_rate_cfm [Double] the ventilation rate in ft^3/min
|
|
20
|
+
# @return [Double] the ventilation fan power in watts
|
|
17
21
|
def model_elevator_fan_pwr(model, vent_rate_cfm)
|
|
18
22
|
vent_pwr_per_flow_w_per_cfm = 0.33
|
|
19
23
|
vent_pwr_w = vent_pwr_per_flow_w_per_cfm * vent_rate_cfm
|
|
@@ -3,17 +3,17 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
3
3
|
|
|
4
4
|
# Determine the prototypical economizer type for the model.
|
|
5
5
|
#
|
|
6
|
-
# @param model [OpenStudio::Model::Model]
|
|
7
|
-
# @param climate_zone [String]
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
7
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
8
8
|
# @return [String] the economizer type. Possible values are:
|
|
9
|
-
#
|
|
10
|
-
#
|
|
11
|
-
#
|
|
12
|
-
#
|
|
13
|
-
#
|
|
14
|
-
#
|
|
15
|
-
#
|
|
16
|
-
#
|
|
9
|
+
# 'NoEconomizer'
|
|
10
|
+
# 'FixedDryBulb'
|
|
11
|
+
# 'FixedEnthalpy'
|
|
12
|
+
# 'DifferentialDryBulb'
|
|
13
|
+
# 'DifferentialEnthalpy'
|
|
14
|
+
# 'FixedDewPointAndDryBulb'
|
|
15
|
+
# 'ElectronicEnthalpy'
|
|
16
|
+
# 'DifferentialDryBulbAndEnthalpy'
|
|
17
17
|
def model_economizer_type(model, climate_zone)
|
|
18
18
|
economizer_type = case climate_zone
|
|
19
19
|
when 'ASHRAE 169-2006-0A',
|
|
@@ -1,8 +1,10 @@
|
|
|
1
1
|
class NRELZNEReady2017 < ASHRAE901
|
|
2
2
|
# @!group hvac_systems
|
|
3
3
|
|
|
4
|
-
# Determine which type of fan the cooling tower
|
|
5
|
-
#
|
|
4
|
+
# Determine which type of fan the cooling tower will have.
|
|
5
|
+
# Variable Speed Fan for NREL ZNE Ready 2017.
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @return [String] the fan type: TwoSpeed Fan, Variable Speed Fan
|
|
7
9
|
def model_cw_loop_cooling_tower_fan_type(model)
|
|
8
10
|
fan_type = 'Variable Speed Fan'
|
|
@@ -4,7 +4,8 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
4
4
|
# Zones with low OA per area get lower initial guesses.
|
|
5
5
|
# Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions
|
|
6
6
|
#
|
|
7
|
-
# @param
|
|
7
|
+
# @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
|
|
8
|
+
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
8
9
|
# @return [Bool] returns true if successful, false if not
|
|
9
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
10
11
|
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
@@ -1,10 +1,11 @@
|
|
|
1
1
|
class ZEAEDGMultifamily < ASHRAE901
|
|
2
2
|
# @!group FanConstantVolume
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for a constant volume
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for a constant volume fan on an AirLoopHVAC based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_constant_volume [OpenStudio::Model::FanConstantVolume] constant volume fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
8
9
|
def fan_constant_volume_airloop_fan_pressure_rise(fan_constant_volume)
|
|
9
10
|
# Get the max flow rate from the fan.
|
|
10
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -1,11 +1,11 @@
|
|
|
1
1
|
class ZEAEDGMultifamily < ASHRAE901
|
|
2
2
|
# @!group FanOnOff
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for an on off
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
# @
|
|
8
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for an on off fan on an AirLoopHVAC or inside a unitary system based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_on_off [OpenStudio::Model::FanOnOff] on off fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
9
9
|
def fan_on_off_airloop_or_unitary_fan_pressure_rise(fan_on_off)
|
|
10
10
|
# Get the max flow rate from the fan.
|
|
11
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -1,10 +1,11 @@
|
|
|
1
1
|
class ZEAEDGMultifamily < ASHRAE901
|
|
2
2
|
# @!group FanVariableVolume
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for a variable volume
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for a variable volume fan on an AirLoopHVAC based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
8
9
|
def fan_variable_volume_airloop_fan_pressure_rise(fan_variable_volume)
|
|
9
10
|
# Get the max flow rate from the fan.
|
|
10
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -2,6 +2,8 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
2
2
|
# @!group HeatExchangerAirToAirSensibleAndLatent
|
|
3
3
|
|
|
4
4
|
# Default fan efficiency assumption for the prm added fan power
|
|
5
|
+
#
|
|
6
|
+
# @return [Double] default fan efficiency
|
|
5
7
|
def heat_exchanger_air_to_air_sensible_and_latent_prototype_default_fan_efficiency
|
|
6
8
|
default_fan_efficiency = 0.55
|
|
7
9
|
return default_fan_efficiency
|
|
@@ -1,19 +1,23 @@
|
|
|
1
1
|
class ZEAEDGMultifamily < ASHRAE901
|
|
2
2
|
# @!group elevators
|
|
3
3
|
|
|
4
|
-
# Determines the percentage of the elevator cab
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determines the percentage of the elevator cab lighting that is incandescent.
|
|
5
|
+
# The remainder is assumed to be LED.
|
|
6
|
+
# Defaults to 0% incandescent (100% LED), representing newer elevators.
|
|
7
|
+
#
|
|
8
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
9
|
+
# @return [Double] incandescent lighting percentage
|
|
8
10
|
def model_elevator_lighting_pct_incandescent(model)
|
|
9
11
|
pct_incandescent = 0.0 # 100% LED
|
|
10
12
|
return pct_incandescent
|
|
11
13
|
end
|
|
12
14
|
|
|
13
15
|
# Determines the power of the elevator ventilation fan.
|
|
14
|
-
# Same as 90.1-2013, which has a requirement
|
|
15
|
-
#
|
|
16
|
-
# @
|
|
16
|
+
# Same as 90.1-2013, which has a requirement for ventilation fan efficiency.
|
|
17
|
+
#
|
|
18
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
19
|
+
# @param vent_rate_cfm [Double] the ventilation rate in ft^3/min
|
|
20
|
+
# @return [Double] the ventilation fan power in watts
|
|
17
21
|
def model_elevator_fan_pwr(model, vent_rate_cfm)
|
|
18
22
|
vent_pwr_per_flow_w_per_cfm = 0.33
|
|
19
23
|
vent_pwr_w = vent_pwr_per_flow_w_per_cfm * vent_rate_cfm
|
|
@@ -3,17 +3,17 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
3
3
|
|
|
4
4
|
# Determine the prototypical economizer type for the model.
|
|
5
5
|
#
|
|
6
|
-
# @param model [OpenStudio::Model::Model]
|
|
7
|
-
# @param climate_zone [String]
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
7
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
8
8
|
# @return [String] the economizer type. Possible values are:
|
|
9
|
-
#
|
|
10
|
-
#
|
|
11
|
-
#
|
|
12
|
-
#
|
|
13
|
-
#
|
|
14
|
-
#
|
|
15
|
-
#
|
|
16
|
-
#
|
|
9
|
+
# 'NoEconomizer'
|
|
10
|
+
# 'FixedDryBulb'
|
|
11
|
+
# 'FixedEnthalpy'
|
|
12
|
+
# 'DifferentialDryBulb'
|
|
13
|
+
# 'DifferentialEnthalpy'
|
|
14
|
+
# 'FixedDewPointAndDryBulb'
|
|
15
|
+
# 'ElectronicEnthalpy'
|
|
16
|
+
# 'DifferentialDryBulbAndEnthalpy'
|
|
17
17
|
def model_economizer_type(model, climate_zone)
|
|
18
18
|
economizer_type = case climate_zone
|
|
19
19
|
when 'ASHRAE 169-2006-0A',
|
|
@@ -1,8 +1,10 @@
|
|
|
1
1
|
class ZEAEDGMultifamily < ASHRAE901
|
|
2
2
|
# @!group hvac_systems
|
|
3
3
|
|
|
4
|
-
# Determine which type of fan the cooling tower
|
|
5
|
-
#
|
|
4
|
+
# Determine which type of fan the cooling tower will have.
|
|
5
|
+
# Variable Speed Fan for NREL ZNE Ready 2017.
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @return [String] the fan type: TwoSpeed Fan, Variable Speed Fan
|
|
7
9
|
def model_cw_loop_cooling_tower_fan_type(model)
|
|
8
10
|
fan_type = 'Variable Speed Fan'
|
|
@@ -3,18 +3,15 @@ class CBES < Standard
|
|
|
3
3
|
|
|
4
4
|
# Add an elevator the the specified space
|
|
5
5
|
#
|
|
6
|
-
# @param space [OpenStudio::Model::Space] the space
|
|
7
|
-
# to assign the elevators to.
|
|
6
|
+
# @param space [OpenStudio::Model::Space] the space to assign the elevators to.
|
|
8
7
|
# @param number_of_elevators [Integer] the number of elevators
|
|
9
|
-
# @param elevator_type [String] valid choices are
|
|
10
|
-
# Traction, Hydraulic
|
|
8
|
+
# @param elevator_type [String] valid choices are Traction, Hydraulic
|
|
11
9
|
# @param elevator_schedule [String] the name of the elevator schedule
|
|
12
10
|
# @param elevator_fan_schedule [String] the name of the elevator fan schedule
|
|
13
11
|
# @param elevator_lights_schedule [String] the name of the elevator lights schedule
|
|
14
12
|
# @param building_type [String] the building type
|
|
15
13
|
# @return [OpenStudio::Model::ElectricEquipment] the resulting elevator
|
|
16
|
-
# @todo Inconsistency. Older vintages don't have lights or fans
|
|
17
|
-
# in elevators, which is not realistic.
|
|
14
|
+
# @todo Inconsistency. Older vintages don't have lights or fans in elevators, which is not realistic.
|
|
18
15
|
def model_add_elevator(model,
|
|
19
16
|
space,
|
|
20
17
|
number_of_elevators,
|
|
@@ -1,10 +1,11 @@
|
|
|
1
1
|
class CBES < Standard
|
|
2
2
|
# @!group refrigeration
|
|
3
3
|
|
|
4
|
-
# Determine the latent case credit curve to use
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
#
|
|
4
|
+
# Determine the latent case credit curve to use for walkins.
|
|
5
|
+
# @todo Should probably use the model_add_refrigeration_walkin and lookups from the spreadsheet instead of hard-coded values.
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
8
|
+
# @return [String] curve name
|
|
8
9
|
def model_walkin_freezer_latent_case_credit_curve(model)
|
|
9
10
|
latent_case_credit_curve_name = 'Single Shelf Horizontal Latent Energy Multiplier_Pre2004'
|
|
10
11
|
return latent_case_credit_curve_name
|
data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb
CHANGED
|
@@ -1,9 +1,11 @@
|
|
|
1
1
|
class CBEST242008 < CBES
|
|
2
2
|
# @!group FanConstantVolume
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for a constant volume
|
|
5
|
-
#
|
|
6
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for a constant volume fan on an AirLoopHVAC based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_constant_volume [OpenStudio::Model::FanConstantVolume] constant volume fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
7
9
|
def fan_constant_volume_airloop_fan_pressure_rise(fan_constant_volume)
|
|
8
10
|
# Get the max flow rate from the fan.
|
|
9
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -1,10 +1,11 @@
|
|
|
1
1
|
class CBEST242008 < CBES
|
|
2
2
|
# @!group FanOnOff
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for an on off
|
|
5
|
-
#
|
|
6
|
-
#
|
|
7
|
-
# @
|
|
4
|
+
# Determine the prototype fan pressure rise for an on off fan on an AirLoopHVAC or inside a unitary system based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_on_off [OpenStudio::Model::FanOnOff] on off fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
8
9
|
def fan_on_off_airloop_or_unitary_fan_pressure_rise(fan_on_off)
|
|
9
10
|
# Get the max flow rate from the fan.
|
|
10
11
|
maximum_flow_rate_m3_per_s = nil
|
data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb
CHANGED
|
@@ -1,9 +1,11 @@
|
|
|
1
1
|
class CBEST242008 < CBES
|
|
2
2
|
# @!group FanVariableVolume
|
|
3
3
|
|
|
4
|
-
# Determine the prototype fan pressure rise for a variable volume
|
|
5
|
-
#
|
|
6
|
-
#
|
|
4
|
+
# Determine the prototype fan pressure rise for a variable volume fan on an AirLoopHVAC based on system airflow.
|
|
5
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
6
|
+
#
|
|
7
|
+
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
8
|
+
# @return [Double] pressure rise in inches H20
|
|
7
9
|
def fan_variable_volume_airloop_fan_pressure_rise(fan_variable_volume)
|
|
8
10
|
# Get the max flow rate from the fan.
|
|
9
11
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -1,47 +1,82 @@
|
|
|
1
1
|
# Custom changes for the College prototype.
|
|
2
|
-
# These are changes that are inconsistent with other prototype
|
|
3
|
-
# building types.
|
|
2
|
+
# These are changes that are inconsistent with other prototype building types.
|
|
4
3
|
module College
|
|
5
|
-
|
|
4
|
+
# hvac adjustments specific to the prototype model
|
|
5
|
+
#
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
7
|
+
# @param building_type [string] the building type
|
|
8
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
9
|
+
# @param prototype_input [Hash] hash of prototype inputs
|
|
10
|
+
# @return [Bool] returns true if successful, false if not
|
|
11
|
+
def model_custom_hvac_tweaks(model, building_type, climate_zone, prototype_input)
|
|
6
12
|
return true
|
|
7
13
|
end
|
|
8
14
|
|
|
9
|
-
|
|
10
|
-
|
|
11
|
-
|
|
12
|
-
|
|
13
|
-
|
|
14
|
-
|
|
15
|
-
|
|
16
|
-
|
|
17
|
-
|
|
18
|
-
|
|
19
|
-
|
|
20
|
-
|
|
21
|
-
|
|
15
|
+
# add door infiltration
|
|
16
|
+
#
|
|
17
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
18
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
19
|
+
# @return [Bool] returns true if successful, false if not
|
|
20
|
+
def add_door_infiltration(climate_zone, model)
|
|
21
|
+
return false if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980'
|
|
22
|
+
|
|
23
|
+
entry_space = model.getSpaceByName('CB_ENTRANCE_LOBBY_F1').get
|
|
24
|
+
infiltration_entrydoor = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
|
25
|
+
infiltration_entrydoor.setName('entry door Infiltration')
|
|
26
|
+
infiltration_per_zone_entrydoor = 0
|
|
27
|
+
if template == '90.1-2004'
|
|
28
|
+
infiltration_per_zone_entrydoor = 7.678585
|
|
29
|
+
infiltration_entrydoor.setSchedule(model_add_schedule(model, 'College INFIL_Door_Opening_SCH'))
|
|
30
|
+
elsif template == '90.1-2007'
|
|
31
|
+
case climate_zone
|
|
32
|
+
when 'ASHRAE 169-2006-3A',
|
|
33
|
+
'ASHRAE 169-2006-3B',
|
|
34
|
+
'ASHRAE 169-2006-3C',
|
|
35
|
+
'ASHRAE 169-2006-4A',
|
|
36
|
+
'ASHRAE 169-2006-4B',
|
|
37
|
+
'ASHRAE 169-2006-4C'
|
|
38
|
+
infiltration_per_zone_entrydoor = 5.600600
|
|
39
|
+
infiltration_entrydoor.setSchedule(model_add_schedule(model, 'College INFIL_Door_Opening_SCH'))
|
|
40
|
+
else
|
|
41
|
+
infiltration_per_zone_entrydoor = 7.678585
|
|
42
|
+
infiltration_entrydoor.setSchedule(model_add_schedule(model, 'College INFIL_Door_Opening_SCH'))
|
|
43
|
+
end
|
|
44
|
+
elsif template == '90.1-2010' || template == '90.1-2013'
|
|
45
|
+
case climate_zone
|
|
46
|
+
when 'ASHRAE 169-2006-3A',
|
|
47
|
+
'ASHRAE 169-2006-3B',
|
|
48
|
+
'ASHRAE 169-2006-3C'
|
|
49
|
+
infiltration_per_zone_entrydoor = 5.600600
|
|
50
|
+
infiltration_entrydoor.setSchedule(model_add_schedule(model, 'College INFIL_Door_Opening_SCH'))
|
|
22
51
|
else
|
|
23
|
-
|
|
24
|
-
|
|
25
|
-
rate.setSchedule(infil_schedule)
|
|
26
|
-
end
|
|
52
|
+
infiltration_per_zone_entrydoor = 7.678585
|
|
53
|
+
infiltration_entrydoor.setSchedule(model_add_schedule(model, 'College INFIL_Door_Opening_SCH'))
|
|
27
54
|
end
|
|
28
55
|
end
|
|
29
|
-
|
|
30
|
-
|
|
31
|
-
|
|
32
|
-
lobby_door_leakage_area.setEffectiveAirLeakageArea(5.0) # Need modification
|
|
33
|
-
lobby_door_leakage_area.setSpace(building_entrance_lobby)
|
|
34
|
-
|
|
35
|
-
# Plugload:Average power density (W/ft2) See under Zone Summary (MISSING)
|
|
36
|
-
# Schedule See under Schedules
|
|
37
|
-
# Zone Control Type: minimum supply air at 30% of the zone design peak supply air
|
|
56
|
+
infiltration_entrydoor.setDesignFlowRate(infiltration_per_zone_entrydoor)
|
|
57
|
+
infiltration_entrydoor.setSpace(entry_space)
|
|
58
|
+
return true
|
|
38
59
|
end
|
|
39
60
|
|
|
61
|
+
# swh adjustments specific to the prototype model
|
|
62
|
+
#
|
|
63
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
64
|
+
# @param building_type [string] the building type
|
|
65
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
66
|
+
# @param prototype_input [Hash] hash of prototype inputs
|
|
67
|
+
# @return [Bool] returns true if successful, false if not
|
|
40
68
|
def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input)
|
|
41
69
|
return true
|
|
42
70
|
end
|
|
43
71
|
|
|
44
|
-
|
|
72
|
+
# geometry adjustments specific to the prototype model
|
|
73
|
+
#
|
|
74
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
75
|
+
# @param building_type [string] the building type
|
|
76
|
+
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
77
|
+
# @param prototype_input [Hash] hash of prototype inputs
|
|
78
|
+
# @return [Bool] returns true if successful, false if not
|
|
79
|
+
def model_custom_geometry_tweaks(model, building_type, climate_zone, prototype_input)
|
|
45
80
|
return true
|
|
46
81
|
end
|
|
47
82
|
end
|