openstudio-standards 0.2.14 → 0.2.15.pre.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.json +0 -19
- data/data/geometry/ASHRAEMidriseApartment.json +47 -47
- data/data/geometry/ASHRAESecondarySchool.osm +2 -2
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/export_OpenStudio_libraries.rb +1 -1
- data/data/standards/manage_OpenStudio_Standards.rb +43 -87
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
- data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
- data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
- data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
- data/lib/openstudio-standards/btap/btap_result.rb +12 -10
- data/lib/openstudio-standards/btap/envelope.rb +2 -2
- data/lib/openstudio-standards/btap/geometry.rb +96 -49
- data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
- data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
- data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
- data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
- data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
- data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
- data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
- data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
- data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
- data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
- data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
- data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
- data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
- data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
- data/lib/openstudio-standards/standards/standard.rb +2 -1
- data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
- data/lib/openstudio-standards/utilities/logging.rb +6 -0
- data/lib/openstudio-standards/utilities/simulation.rb +30 -14
- data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
- data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
- data/lib/openstudio-standards/version.rb +2 -2
- data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
- data/lib/openstudio-standards.rb +9 -0
- metadata +106 -205
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
- data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
|
@@ -3,6 +3,8 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype AirConditionerVariableRefrigerantFlow object
|
|
5
5
|
# Enters in default curves for coil by type of coil
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
7
9
|
# @param schedule [String] name of the availability schedule, or [<OpenStudio::Model::Schedule>] Schedule object, or nil in which case default to always on
|
|
8
10
|
# @param type [String] the type of unit to reference for the correct curve set
|
|
@@ -16,6 +18,7 @@ class Standard
|
|
|
16
18
|
# @param master_zone [<OpenStudio::Model::ThermalZone>] master control zone to switch between heating and cooling
|
|
17
19
|
# @param priority_control_type [String] type of master thermostat priority control type
|
|
18
20
|
# options are LoadPriority, ZonePriority, ThermostatOffsetPriority, MasterThermostatPriority
|
|
21
|
+
# @return [OpenStudio::Model::AirConditionerVariableRefrigerantFlow] the vrf unit
|
|
19
22
|
def create_air_conditioner_variable_refrigerant_flow(model,
|
|
20
23
|
name: 'VRF System',
|
|
21
24
|
schedule: nil,
|
data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb
CHANGED
|
@@ -5,7 +5,8 @@ class Standard
|
|
|
5
5
|
# Zones with low OA per area get lower initial guesses.
|
|
6
6
|
# Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions
|
|
7
7
|
#
|
|
8
|
-
# @param
|
|
8
|
+
# @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
|
|
9
|
+
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
9
10
|
# @return [Bool] returns true if successful, false if not
|
|
10
11
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
11
12
|
min_damper_position = 0.3
|
|
@@ -3,6 +3,7 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype BoilerHotWater object
|
|
5
5
|
#
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
7
|
# @param hot_water_loop [<OpenStudio::Model::PlantLoop>] a hot water loop served by the boiler
|
|
7
8
|
# @param name [String] the name of the boiler, or nil in which case it will be defaulted
|
|
8
9
|
# @param fuel_type [String] type of fuel serving the boiler
|
|
@@ -17,6 +18,7 @@ class Standard
|
|
|
17
18
|
# @param max_plr [Double] boiler maximum part load ratio
|
|
18
19
|
# @param opt_plr [Double] boiler optimum part load ratio
|
|
19
20
|
# @param sizing_factor [Double] boiler oversizing factor
|
|
21
|
+
# @return [OpenStudio::Model::BoilerHotWater] the boiler object
|
|
20
22
|
def create_boiler_hot_water(model,
|
|
21
23
|
hot_water_loop: nil,
|
|
22
24
|
name: 'Boiler',
|
data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb
CHANGED
|
@@ -3,9 +3,11 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype CentralAirSourceHeatPump object using PlantComponentUserDefined
|
|
5
5
|
#
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
7
|
# @param hot_water_loop [<OpenStudio::Model::PlantLoop>] a hot water loop served by the central air source heat pump
|
|
7
8
|
# @param name [String] the name of the central air source heat pump, or nil in which case it will be defaulted
|
|
8
9
|
# @param cop [Double] air source heat pump rated cop
|
|
10
|
+
# @return [OpenStudio::Model::PlantComponentUserDefined] a plant component representing the air source heat pump
|
|
9
11
|
# @todo update curve to better calculate based on the rated cop
|
|
10
12
|
# @todo refactor to use the new EnergyPlus central air source heat pump object when it becomes available
|
|
11
13
|
# set hot_water_loop to an optional keyword argument, and add input keyword arguments for other characteristics
|
data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb
CHANGED
|
@@ -3,11 +3,14 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype CoilCoolingDXSingleSpeed object
|
|
5
5
|
# Enters in default curves for coil by type of coil
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
7
9
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
8
10
|
# @param schedule [String] name of the availability schedule, or [<OpenStudio::Model::Schedule>] Schedule object, or nil in which case default to always on
|
|
9
11
|
# @param type [String] the type of single speed DX coil to reference the correct curve set
|
|
10
12
|
# @param cop [Double] rated cooling coefficient of performance
|
|
13
|
+
# @return [OpenStudio::Model::CoilCoolingDXTwoSpeed] the DX cooling coil
|
|
11
14
|
def create_coil_cooling_dx_single_speed(model,
|
|
12
15
|
air_loop_node: nil,
|
|
13
16
|
name: '1spd DX Clg Coil',
|
|
@@ -157,7 +160,7 @@ class Standard
|
|
|
157
160
|
when 'Window AC'
|
|
158
161
|
# Performance curves
|
|
159
162
|
# From Frigidaire 10.7 EER unit in Winkler et. al. Lab Testing of Window ACs (2013)
|
|
160
|
-
#
|
|
163
|
+
# @note These coefficients are in SI UNITS
|
|
161
164
|
cool_cap_ft_coeffs_si = [0.6405, 0.01568, 0.0004531, 0.001615, -0.0001825, 0.00006614]
|
|
162
165
|
cool_eir_ft_coeffs_si = [2.287, -0.1732, 0.004745, 0.01662, 0.000484, -0.001306]
|
|
163
166
|
cool_cap_fflow_coeffs = [0.887, 0.1128, 0]
|
|
@@ -3,10 +3,13 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype CoilCoolingDXTwoSpeed object
|
|
5
5
|
# Enters in default curves for coil by type of coil
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
7
9
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
8
10
|
# @param schedule [String] name of the availability schedule, or [<OpenStudio::Model::Schedule>] Schedule object, or nil in which case default to always on
|
|
9
11
|
# @param type [String] the type of two speed DX coil to reference the correct curve set
|
|
12
|
+
# @return [OpenStudio::Model::CoilCoolingDXTwoSpeed] the DX cooling coil
|
|
10
13
|
def create_coil_cooling_dx_two_speed(model,
|
|
11
14
|
air_loop_node: nil,
|
|
12
15
|
name: '2spd DX Clg Coil',
|
|
@@ -2,6 +2,8 @@ class Standard
|
|
|
2
2
|
# @!group CoilCoolingWater
|
|
3
3
|
|
|
4
4
|
# Prototype CoilCoolingWater object
|
|
5
|
+
#
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5
7
|
# @param chilled_water_loop [<OpenStudio::Model::PlantLoop>] the coil will be placed on the demand side of this plant loop
|
|
6
8
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
7
9
|
# @param name [String] the name of the coil, or nil in which case it will be defaulted
|
|
@@ -9,6 +11,7 @@ class Standard
|
|
|
9
11
|
# @param design_inlet_water_temperature [Double] design inlet water temperature in degrees Celsius, default is nil
|
|
10
12
|
# @param design_inlet_air_temperature [Double] design inlet air temperature in degrees Celsius, default is nil
|
|
11
13
|
# @param design_outlet_air_temperature [Double] design outlet air temperature in degrees Celsius, default is nil
|
|
14
|
+
# @return [OpenStudio::Model::CoilCoolingWater] the cooling coil
|
|
12
15
|
def create_coil_cooling_water(model,
|
|
13
16
|
chilled_water_loop,
|
|
14
17
|
air_loop_node: nil,
|
|
@@ -65,7 +68,7 @@ class Standard
|
|
|
65
68
|
clg_coil.setHeatExchangerConfiguration('CrossFlow')
|
|
66
69
|
|
|
67
70
|
# coil controller properties
|
|
68
|
-
#
|
|
71
|
+
# @note These inputs will get overwritten if addToNode or addDemandBranchForComponent is called on the htg_coil object after this
|
|
69
72
|
clg_coil_controller = clg_coil.controllerWaterCoil.get
|
|
70
73
|
clg_coil_controller.setName("#{clg_coil.name} Controller")
|
|
71
74
|
clg_coil_controller.setAction('Reverse')
|
|
@@ -3,11 +3,14 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype CoilCoolingWaterToAirHeatPumpEquationFit object
|
|
5
5
|
# Enters in default curves for coil by type of coil
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @param plant_loop [<OpenStudio::Model::PlantLoop>] the coil will be placed on the demand side of this plant loop
|
|
7
9
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
8
10
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
9
11
|
# @param type [String] the type of coil to reference the correct curve set
|
|
10
12
|
# @param cop [Double] rated cooling coefficient of performance
|
|
13
|
+
# @return [OpenStudio::Model::CoilCoolingWaterToAirHeatPumpEquationFit] the cooling coil
|
|
11
14
|
def create_coil_cooling_water_to_air_heat_pump_equation_fit(model,
|
|
12
15
|
plant_loop,
|
|
13
16
|
air_loop_node: nil,
|
data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb
CHANGED
|
@@ -3,12 +3,15 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype CoilHeatingDXSingleSpeed object
|
|
5
5
|
# Enters in default curves for coil by type of coil
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
7
9
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
8
10
|
# @param schedule [String] name of the availability schedule, or [<OpenStudio::Model::Schedule>] Schedule object, or nil in which case default to always on
|
|
9
11
|
# @param type [String] the type of single speed DX coil to reference the correct curve set
|
|
10
12
|
# @param cop [Double] rated heating coefficient of performance
|
|
11
13
|
# @param defrost_strategy [String] type of defrost strategy. options are reverse-cycle or resistive
|
|
14
|
+
# @return [OpenStudio::Model::CoilHeatingDXSingleSpeed] the DX heating coil
|
|
12
15
|
def create_coil_heating_dx_single_speed(model,
|
|
13
16
|
air_loop_node: nil,
|
|
14
17
|
name: '1spd DX Htg Coil',
|
|
@@ -194,6 +197,10 @@ class Standard
|
|
|
194
197
|
return htg_coil
|
|
195
198
|
end
|
|
196
199
|
|
|
200
|
+
# sets defrost curve limits
|
|
201
|
+
#
|
|
202
|
+
# @param htg_coil [OpenStudio::Model::CoilHeatingDXSingleSpeed] a DX heating coil
|
|
203
|
+
# @return [Bool] returns true if successful, false if not
|
|
197
204
|
def coil_heating_dx_single_speed_apply_defrost_eir_curve_limits(htg_coil)
|
|
198
205
|
return false unless htg_coil.defrostEnergyInputRatioFunctionofTemperatureCurve.is_initialized
|
|
199
206
|
|
|
@@ -202,5 +209,7 @@ class Standard
|
|
|
202
209
|
def_eir_f_of_temp.setMaximumValueofx(23.88889)
|
|
203
210
|
def_eir_f_of_temp.setMinimumValueofy(21.11111)
|
|
204
211
|
def_eir_f_of_temp.setMaximumValueofy(46.11111)
|
|
212
|
+
|
|
213
|
+
return true
|
|
205
214
|
end
|
|
206
215
|
end
|
|
@@ -2,11 +2,14 @@ class Standard
|
|
|
2
2
|
# @!group CoilHeatingElectric
|
|
3
3
|
|
|
4
4
|
# Prototype CoilHeatingElectric object
|
|
5
|
+
#
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5
7
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
6
8
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
7
9
|
# @param schedule [String] name of the availability schedule, or [<OpenStudio::Model::Schedule>] Schedule object, or nil in which case default to always on
|
|
8
10
|
# @param nominal_capacity [Double] rated nominal capacity
|
|
9
11
|
# @param efficiency [Double] rated heating efficiency
|
|
12
|
+
# @return [OpenStudio::Model::CoilHeatingElectric] the electric heating coil
|
|
10
13
|
def create_coil_heating_electric(model,
|
|
11
14
|
air_loop_node: nil,
|
|
12
15
|
name: 'Electric Htg Coil',
|
|
@@ -2,11 +2,14 @@ class Standard
|
|
|
2
2
|
# @!group CoilHeatingGas
|
|
3
3
|
|
|
4
4
|
# Prototype CoilHeatingGas object
|
|
5
|
+
#
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5
7
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
6
8
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
7
9
|
# @param schedule [String] name of the availability schedule, or [<OpenStudio::Model::Schedule>] Schedule object, or nil in which case default to always on
|
|
8
10
|
# @param nominal_capacity [Double] rated nominal capacity
|
|
9
11
|
# @param efficiency [Double] rated heating efficiency
|
|
12
|
+
# @return [OpenStudio::Model::CoilHeatingGas] the gas heating coil
|
|
10
13
|
def create_coil_heating_gas(model,
|
|
11
14
|
air_loop_node: nil,
|
|
12
15
|
name: 'Gas Htg Coil',
|
|
@@ -54,11 +57,13 @@ class Standard
|
|
|
54
57
|
return htg_coil
|
|
55
58
|
end
|
|
56
59
|
|
|
57
|
-
# Updates the efficiency of some gas heating coils
|
|
58
|
-
#
|
|
59
|
-
#
|
|
60
|
+
# Updates the efficiency of some gas heating coils per the prototype assumptions.
|
|
61
|
+
# Defaults to making no changes.
|
|
62
|
+
#
|
|
63
|
+
# @param coil_heating_gas [OpenStudio::Model::CoilHeatingGas] a gas heating coil
|
|
64
|
+
# @return [Bool] returns true if successful, false if not
|
|
60
65
|
def coil_heating_gas_apply_prototype_efficiency(coil_heating_gas)
|
|
61
|
-
#
|
|
66
|
+
# do nothing
|
|
62
67
|
return true
|
|
63
68
|
end
|
|
64
69
|
end
|
|
@@ -2,6 +2,8 @@ class Standard
|
|
|
2
2
|
# @!group CoilHeatingWater
|
|
3
3
|
|
|
4
4
|
# Prototype CoilHeatingWater object
|
|
5
|
+
#
|
|
6
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5
7
|
# @param hot_water_loop [<OpenStudio::Model::PlantLoop>] the coil will be placed on the demand side of this plant loop
|
|
6
8
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
7
9
|
# @param name [String] the name of the coil, or nil in which case it will be defaulted
|
|
@@ -11,6 +13,7 @@ class Standard
|
|
|
11
13
|
# @param rated_inlet_air_temperature [Double] rated inlet air temperature in degrees Celsius, default is 16.6 (62F)
|
|
12
14
|
# @param rated_outlet_air_temperature [Double] rated outlet air temperature in degrees Celsius, default is 32.2 (90F)
|
|
13
15
|
# @param controller_convergence_tolerance [Double] controller convergence tolerance
|
|
16
|
+
# @return [OpenStudio::Model::CoilHeatingWater] the heating coil
|
|
14
17
|
def create_coil_heating_water(model,
|
|
15
18
|
hot_water_loop,
|
|
16
19
|
air_loop_node: nil,
|
|
@@ -83,7 +86,7 @@ class Standard
|
|
|
83
86
|
end
|
|
84
87
|
|
|
85
88
|
# coil controller properties
|
|
86
|
-
#
|
|
89
|
+
# @note These inputs will get overwritten if addToNode or addDemandBranchForComponent is called on the htg_coil object after this
|
|
87
90
|
htg_coil_controller = htg_coil.controllerWaterCoil.get
|
|
88
91
|
htg_coil_controller.setName("#{htg_coil.name} Controller")
|
|
89
92
|
htg_coil_controller.setMinimumActuatedFlow(0.0)
|
|
@@ -3,11 +3,14 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Prototype CoilHeatingWaterToAirHeatPumpEquationFit object
|
|
5
5
|
# Enters in default curves for coil by type of coil
|
|
6
|
+
#
|
|
7
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
6
8
|
# @param plant_loop [<OpenStudio::Model::PlantLoop>] the coil will be placed on the demand side of this plant loop
|
|
7
9
|
# @param air_loop_node [<OpenStudio::Model::Node>] the coil will be placed on this node of the air loop
|
|
8
10
|
# @param name [String] the name of the system, or nil in which case it will be defaulted
|
|
9
11
|
# @param type [String] the type of coil to reference the correct curve set
|
|
10
12
|
# @param cop [Double] rated heating coefficient of performance
|
|
13
|
+
# @return [OpenStudio::Model::CoilHeatingWaterToAirHeatPumpEquationFit] the heating coil
|
|
11
14
|
def create_coil_heating_water_to_air_heat_pump_equation_fit(model,
|
|
12
15
|
plant_loop,
|
|
13
16
|
air_loop_node: nil,
|
|
@@ -3,9 +3,9 @@ class Standard
|
|
|
3
3
|
|
|
4
4
|
# Sets the convergence tolerance to 0.0001 deltaC for all hot water coils.
|
|
5
5
|
#
|
|
6
|
+
# @param controller_water_coil [OpenStudio::Model::ControllerWaterCoil] controller water coil object
|
|
6
7
|
# @return [Bool] returns true if successful, false if not
|
|
7
|
-
# @
|
|
8
|
-
# because it seems like a workaround for an E+ bug that was probably addressed long ago.
|
|
8
|
+
# @todo Figure out what the reason for this is, because it seems like a workaround for an E+ bug that was probably addressed long ago.
|
|
9
9
|
def controller_water_coil_set_convergence_limits(controller_water_coil)
|
|
10
10
|
controller_action = controller_water_coil.action
|
|
11
11
|
if controller_action.is_initialized
|
|
@@ -4,7 +4,8 @@ class Standard
|
|
|
4
4
|
# Apply approach temperature sizing criteria to a condenser water loop
|
|
5
5
|
#
|
|
6
6
|
# @param condenser_loop [<OpenStudio::Model::PlantLoop>] a condenser loop served by a cooling tower
|
|
7
|
-
# @param design_wet_bulb_c [Double] the outdoor design wetbulb conditions in degrees
|
|
7
|
+
# @param design_wet_bulb_c [Double] the outdoor design wetbulb conditions in degrees Celsius
|
|
8
|
+
# @return [Bool] returns true if successful, false if not
|
|
8
9
|
def prototype_apply_condenser_water_temperatures(condenser_loop,
|
|
9
10
|
design_wet_bulb_c: nil)
|
|
10
11
|
sizing_plant = condenser_loop.sizingPlant
|
|
@@ -99,6 +100,8 @@ class Standard
|
|
|
99
100
|
cw_t_stpt_manager.setMaximumSetpointTemperature(leaving_cw_t_c)
|
|
100
101
|
cw_t_stpt_manager.setMinimumSetpointTemperature(float_down_to_c)
|
|
101
102
|
cw_t_stpt_manager.setOffsetTemperatureDifference(approach_k)
|
|
103
|
+
|
|
104
|
+
return true
|
|
102
105
|
end
|
|
103
106
|
|
|
104
107
|
# Determine the performance rating method specified design condenser water temperature, approach, and range
|
|
@@ -7,7 +7,9 @@ module PrototypeFan
|
|
|
7
7
|
# model assumptions for fan impeller efficiency,
|
|
8
8
|
# motor type, and a 10% safety factor on brake horsepower.
|
|
9
9
|
#
|
|
10
|
-
# @
|
|
10
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object of type:
|
|
11
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
|
12
|
+
# @return [Bool] returns true if successful, false if not
|
|
11
13
|
def prototype_fan_apply_prototype_fan_efficiency(fan)
|
|
12
14
|
# Do not modify dummy exhaust fans
|
|
13
15
|
return true unless !fan.name.to_s.downcase.include? 'dummy'
|
|
@@ -35,7 +37,8 @@ module PrototypeFan
|
|
|
35
37
|
|
|
36
38
|
# Calculate the Brake Horsepower
|
|
37
39
|
brake_hp = (pressure_rise_in_h2o * maximum_flow_rate_cfm) / (fan_impeller_eff * 6356)
|
|
38
|
-
allowed_hp = brake_hp * 1.1 # Per PNNL document
|
|
40
|
+
allowed_hp = brake_hp * 1.1 # Per PNNL document
|
|
41
|
+
# @todo add reference
|
|
39
42
|
if allowed_hp > 0.1
|
|
40
43
|
allowed_hp = allowed_hp.round(2) + 0.0001
|
|
41
44
|
elsif allowed_hp < 0.01
|
|
@@ -70,6 +73,15 @@ module PrototypeFan
|
|
|
70
73
|
return true
|
|
71
74
|
end
|
|
72
75
|
|
|
76
|
+
# fan class method to apply fan variables
|
|
77
|
+
#
|
|
78
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object of type:
|
|
79
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
|
80
|
+
# @param fan_name [String] fan name
|
|
81
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
82
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
83
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
84
|
+
# @return [OpenStudio::Model::StraightComponent] fan object
|
|
73
85
|
def self.apply_base_fan_variables(fan,
|
|
74
86
|
fan_name: nil,
|
|
75
87
|
fan_efficiency: nil,
|
|
@@ -82,6 +94,8 @@ module PrototypeFan
|
|
|
82
94
|
return fan
|
|
83
95
|
end
|
|
84
96
|
|
|
97
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
98
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
85
99
|
def get_fan_from_standards(standards_name: nil,
|
|
86
100
|
type: nil,
|
|
87
101
|
fan_efficiency: nil,
|
|
@@ -115,6 +129,13 @@ module PrototypeFan
|
|
|
115
129
|
model_find_object(@standards_data['fans'], search_criteria)
|
|
116
130
|
end
|
|
117
131
|
|
|
132
|
+
# create a fan with properties for a fan name in the standards data
|
|
133
|
+
#
|
|
134
|
+
# @param fan_name [String] fan name
|
|
135
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
136
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
137
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
138
|
+
# @return [OpenStudio::Model::StraightComponent] fan object
|
|
118
139
|
def create_fan_by_name(model,
|
|
119
140
|
standards_name,
|
|
120
141
|
fan_name: nil,
|
|
@@ -5,6 +5,9 @@ class Standard
|
|
|
5
5
|
# Sets the fan pressure rise based on the Prototype buildings inputs
|
|
6
6
|
# which are governed by the flow rate coming through the fan
|
|
7
7
|
# and whether the fan lives inside a unit heater, PTAC, etc.
|
|
8
|
+
#
|
|
9
|
+
# @param fan_constant_volume [OpenStudio::Model::FanConstantVolume] constant volume fan object
|
|
10
|
+
# @return [Bool] returns true if successful, false if not
|
|
8
11
|
def fan_constant_volume_apply_prototype_fan_pressure_rise(fan_constant_volume)
|
|
9
12
|
# Don't modify unit heater fans
|
|
10
13
|
return true if fan_constant_volume.name.to_s.include?('UnitHeater Fan')
|
|
@@ -53,10 +56,11 @@ class Standard
|
|
|
53
56
|
return true
|
|
54
57
|
end
|
|
55
58
|
|
|
56
|
-
# Determine the prototype fan pressure rise for a constant volume
|
|
57
|
-
#
|
|
58
|
-
#
|
|
59
|
-
#
|
|
59
|
+
# Determine the prototype fan pressure rise for a constant volume fan on an AirLoopHVAC based on system airflow.
|
|
60
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
61
|
+
#
|
|
62
|
+
# @param fan_constant_volume [OpenStudio::Model::FanConstantVolume] constant volume fan object
|
|
63
|
+
# @return [Double] pressure rise in inches H20
|
|
60
64
|
def fan_constant_volume_airloop_fan_pressure_rise(fan_constant_volume)
|
|
61
65
|
# Get the max flow rate from the fan.
|
|
62
66
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -84,6 +88,16 @@ class Standard
|
|
|
84
88
|
return pressure_rise_in_h2o
|
|
85
89
|
end
|
|
86
90
|
|
|
91
|
+
# creates a constant volume fan
|
|
92
|
+
#
|
|
93
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
94
|
+
# @param fan_name [String] fan name
|
|
95
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
96
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
97
|
+
# @param motor_efficiency [Double] fan motor efficiency
|
|
98
|
+
# @param motor_in_airstream_fraction [Double] fraction of motor heat in airstream
|
|
99
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
100
|
+
# @return [OpenStudio::Model::FanConstantVolume] constant volume fan object
|
|
87
101
|
def create_fan_constant_volume(model,
|
|
88
102
|
fan_name: nil,
|
|
89
103
|
fan_efficiency: nil,
|
|
@@ -102,6 +116,17 @@ class Standard
|
|
|
102
116
|
return fan
|
|
103
117
|
end
|
|
104
118
|
|
|
119
|
+
# creates a constant volume fan from a json
|
|
120
|
+
#
|
|
121
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
122
|
+
# @param fan_json [Hash] hash of fan properties
|
|
123
|
+
# @param fan_name [String] fan name
|
|
124
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
125
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
126
|
+
# @param motor_efficiency [Double] fan motor efficiency
|
|
127
|
+
# @param motor_in_airstream_fraction [Double] fraction of motor heat in airstream
|
|
128
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
129
|
+
# @return [OpenStudio::Model::FanConstantVolume] constant volume fan object
|
|
105
130
|
def create_fan_constant_volume_from_json(model,
|
|
106
131
|
fan_json,
|
|
107
132
|
fan_name: nil,
|
|
@@ -6,6 +6,9 @@ class Standard
|
|
|
6
6
|
# Sets the fan pressure rise based on the Prototype buildings inputs
|
|
7
7
|
# which are governed by the flow rate coming through the fan
|
|
8
8
|
# and whether the fan lives inside a unit heater, PTAC, etc.
|
|
9
|
+
#
|
|
10
|
+
# @param fan_on_off [OpenStudio::Model::FanOnOff] on off fan object
|
|
11
|
+
# @return [Bool] returns true if successful, false if not
|
|
9
12
|
def fan_on_off_apply_prototype_fan_pressure_rise(fan_on_off)
|
|
10
13
|
# Get the max flow rate from the fan.
|
|
11
14
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -58,11 +61,11 @@ class Standard
|
|
|
58
61
|
return true
|
|
59
62
|
end
|
|
60
63
|
|
|
61
|
-
# Determine the prototype fan pressure rise for an on off
|
|
62
|
-
#
|
|
63
|
-
#
|
|
64
|
-
# @
|
|
65
|
-
#
|
|
64
|
+
# Determine the prototype fan pressure rise for an on off fan on an AirLoopHVAC or inside a unitary system based on system airflow.
|
|
65
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
66
|
+
#
|
|
67
|
+
# @param fan_on_off [OpenStudio::Model::FanOnOff] on off fan object
|
|
68
|
+
# @return [Double] pressure rise in inches H20
|
|
66
69
|
def fan_on_off_airloop_or_unitary_fan_pressure_rise(fan_on_off)
|
|
67
70
|
# Get the max flow rate from the fan.
|
|
68
71
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -90,6 +93,16 @@ class Standard
|
|
|
90
93
|
return pressure_rise_in_h2o
|
|
91
94
|
end
|
|
92
95
|
|
|
96
|
+
# creates an on off fan
|
|
97
|
+
#
|
|
98
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
99
|
+
# @param fan_name [String] fan name
|
|
100
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
101
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
102
|
+
# @param motor_efficiency [Double] fan motor efficiency
|
|
103
|
+
# @param motor_in_airstream_fraction [Double] fraction of motor heat in airstream
|
|
104
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
105
|
+
# @return [OpenStudio::Model::FanOnOff] on off fan object
|
|
93
106
|
def create_fan_on_off(model,
|
|
94
107
|
fan_name: nil,
|
|
95
108
|
fan_efficiency: nil,
|
|
@@ -108,6 +121,17 @@ class Standard
|
|
|
108
121
|
return fan
|
|
109
122
|
end
|
|
110
123
|
|
|
124
|
+
# creates a on off fan from a json
|
|
125
|
+
#
|
|
126
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
127
|
+
# @param fan_json [Hash] hash of fan properties
|
|
128
|
+
# @param fan_name [String] fan name
|
|
129
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
130
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
131
|
+
# @param motor_efficiency [Double] fan motor efficiency
|
|
132
|
+
# @param motor_in_airstream_fraction [Double] fraction of motor heat in airstream
|
|
133
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
134
|
+
# @return [OpenStudio::Model::FanOnOff] on off fan object
|
|
111
135
|
def create_fan_on_off_from_json(model,
|
|
112
136
|
fan_json,
|
|
113
137
|
fan_name: nil,
|
|
@@ -6,6 +6,9 @@ class Standard
|
|
|
6
6
|
# Sets the fan pressure rise based on the Prototype buildings inputs
|
|
7
7
|
# which are governed by the flow rate coming through the fan
|
|
8
8
|
# and whether the fan lives inside a unit heater, PTAC, etc.
|
|
9
|
+
#
|
|
10
|
+
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
11
|
+
# @return [Bool] returns true if successful, false if not
|
|
9
12
|
def fan_variable_volume_apply_prototype_fan_pressure_rise(fan_variable_volume)
|
|
10
13
|
# Get the max flow rate from the fan.
|
|
11
14
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -51,10 +54,11 @@ class Standard
|
|
|
51
54
|
return true
|
|
52
55
|
end
|
|
53
56
|
|
|
54
|
-
# Determine the prototype fan pressure rise for a variable volume
|
|
55
|
-
#
|
|
56
|
-
#
|
|
57
|
-
#
|
|
57
|
+
# Determine the prototype fan pressure rise for a variable volume fan on an AirLoopHVAC based on system airflow.
|
|
58
|
+
# Defaults to the logic from ASHRAE 90.1-2004 prototypes.
|
|
59
|
+
#
|
|
60
|
+
# @param fan_variable_volume [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
61
|
+
# @return [Double] pressure rise in inches H20
|
|
58
62
|
def fan_variable_volume_airloop_fan_pressure_rise(fan_variable_volume)
|
|
59
63
|
# Get the max flow rate from the fan.
|
|
60
64
|
maximum_flow_rate_m3_per_s = nil
|
|
@@ -82,6 +86,23 @@ class Standard
|
|
|
82
86
|
return pressure_rise_in_h2o
|
|
83
87
|
end
|
|
84
88
|
|
|
89
|
+
# creates a variable volume fan
|
|
90
|
+
#
|
|
91
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
92
|
+
# @param fan_name [String] fan name
|
|
93
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
94
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
95
|
+
# @param motor_efficiency [Double] fan motor efficiency
|
|
96
|
+
# @param motor_in_airstream_fraction [Double] fraction of motor heat in airstream
|
|
97
|
+
# @param fan_power_minimum_flow_rate_input_method [String] options are Fraction, FixedFlowRate
|
|
98
|
+
# @param fan_power_minimum_flow_rate_fraction [Double] minimum flow rate fraction
|
|
99
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
100
|
+
# @param fan_power_coefficient_1 [Double] fan power coefficient 1
|
|
101
|
+
# @param fan_power_coefficient_2 [Double] fan power coefficient 2
|
|
102
|
+
# @param fan_power_coefficient_3 [Double] fan power coefficient 3
|
|
103
|
+
# @param fan_power_coefficient_4 [Double] fan power coefficient 4
|
|
104
|
+
# @param fan_power_coefficient_5 [Double] fan power coefficient 5
|
|
105
|
+
# @return [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
85
106
|
def create_fan_variable_volume(model,
|
|
86
107
|
fan_name: nil,
|
|
87
108
|
fan_efficiency: nil,
|
|
@@ -114,6 +135,24 @@ class Standard
|
|
|
114
135
|
return fan
|
|
115
136
|
end
|
|
116
137
|
|
|
138
|
+
# creates a variable volume fan from a json
|
|
139
|
+
#
|
|
140
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
141
|
+
# @param fan_json [Hash] hash of fan properties
|
|
142
|
+
# @param fan_name [String] fan name
|
|
143
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
144
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
145
|
+
# @param motor_efficiency [Double] fan motor efficiency
|
|
146
|
+
# @param motor_in_airstream_fraction [Double] fraction of motor heat in airstream
|
|
147
|
+
# @param fan_power_minimum_flow_rate_input_method [String] options are Fraction, FixedFlowRate
|
|
148
|
+
# @param fan_power_minimum_flow_rate_fraction [Double] minimum flow rate fraction
|
|
149
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
150
|
+
# @param fan_power_coefficient_1 [Double] fan power coefficient 1
|
|
151
|
+
# @param fan_power_coefficient_2 [Double] fan power coefficient 2
|
|
152
|
+
# @param fan_power_coefficient_3 [Double] fan power coefficient 3
|
|
153
|
+
# @param fan_power_coefficient_4 [Double] fan power coefficient 4
|
|
154
|
+
# @param fan_power_coefficient_5 [Double] fan power coefficient 5
|
|
155
|
+
# @return [OpenStudio::Model::FanVariableVolume] variable volume fan object
|
|
117
156
|
def create_fan_variable_volume_from_json(model,
|
|
118
157
|
fan_json,
|
|
119
158
|
fan_name: nil,
|
|
@@ -4,6 +4,9 @@ class Standard
|
|
|
4
4
|
include PrototypeFan
|
|
5
5
|
|
|
6
6
|
# Sets the fan pressure rise based on the Prototype buildings inputs
|
|
7
|
+
#
|
|
8
|
+
# @param fan_zone_exhaust [OpenStudio::Model::FanZoneExhaust] the exhaust fan
|
|
9
|
+
# @return [Bool] returns true if successful, false if not
|
|
7
10
|
def fan_zone_exhaust_apply_prototype_fan_pressure_rise(fan_zone_exhaust)
|
|
8
11
|
# Do not modify dummy exhaust fans
|
|
9
12
|
return true if fan_zone_exhaust.name.to_s.downcase.include? 'dummy'
|
|
@@ -21,6 +24,16 @@ class Standard
|
|
|
21
24
|
return true
|
|
22
25
|
end
|
|
23
26
|
|
|
27
|
+
# creates a FanZoneExhaust from a json
|
|
28
|
+
#
|
|
29
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
30
|
+
# @param fan_json [Hash] hash of fan properties
|
|
31
|
+
# @param fan_name [String] fan name
|
|
32
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
33
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
34
|
+
# @param system_availability_manager_coupling_mode [String] coupling mode, options are Coupled, Decoupled
|
|
35
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
36
|
+
# @return [OpenStudio::Model::FanZoneExhaust] the exhaust fan
|
|
24
37
|
def create_fan_zone_exhaust_from_json(model,
|
|
25
38
|
fan_json,
|
|
26
39
|
fan_name: nil,
|
|
@@ -47,6 +60,15 @@ class Standard
|
|
|
47
60
|
return fan
|
|
48
61
|
end
|
|
49
62
|
|
|
63
|
+
# creates a FanZoneExhaust
|
|
64
|
+
#
|
|
65
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
66
|
+
# @param fan_name [String] fan name
|
|
67
|
+
# @param fan_efficiency [Double] fan efficiency
|
|
68
|
+
# @param pressure_rise [Double] fan pressure rise in Pa
|
|
69
|
+
# @param system_availability_manager_coupling_mode [String] coupling mode, options are Coupled, Decoupled
|
|
70
|
+
# @param end_use_subcategory [String] end use subcategory name
|
|
71
|
+
# @return [OpenStudio::Model::FanZoneExhaust] the exhaust fan
|
|
50
72
|
def create_fan_zone_exhaust(model,
|
|
51
73
|
fan_name: nil,
|
|
52
74
|
fan_efficiency: nil,
|