openstudio-standards 0.2.14 → 0.2.15.pre.rc1

Sign up to get free protection for your applications and to get access to all the features.
Files changed (642) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.json +0 -19
  3. data/data/geometry/ASHRAEMidriseApartment.json +47 -47
  4. data/data/geometry/ASHRAESecondarySchool.osm +2 -2
  5. data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
  6. data/data/standards/export_OpenStudio_libraries.rb +1 -1
  7. data/data/standards/manage_OpenStudio_Standards.rb +43 -87
  8. data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
  9. data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
  10. data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
  11. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
  12. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
  13. data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
  14. data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
  15. data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
  16. data/lib/openstudio-standards/btap/btap_result.rb +12 -10
  17. data/lib/openstudio-standards/btap/envelope.rb +2 -2
  18. data/lib/openstudio-standards/btap/geometry.rb +96 -49
  19. data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
  20. data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
  21. data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
  22. data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
  23. data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
  24. data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
  25. data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
  26. data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
  27. data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
  28. data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
  29. data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
  30. data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
  31. data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
  32. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
  33. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
  34. data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
  35. data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
  36. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  37. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
  38. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
  39. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
  40. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
  41. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
  42. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
  43. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
  44. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
  45. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
  46. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
  47. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
  50. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
  51. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
  52. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
  53. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
  54. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
  55. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
  56. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
  57. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
  58. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
  59. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
  60. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
  61. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
  62. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
  63. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
  64. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
  65. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
  66. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
  67. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
  68. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
  69. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
  70. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
  71. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
  72. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
  73. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
  74. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
  75. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
  76. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
  77. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
  78. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
  79. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
  80. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
  81. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
  82. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
  83. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
  84. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
  85. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
  86. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
  87. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  88. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
  89. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
  90. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
  91. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
  92. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
  93. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
  99. data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
  100. data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
  101. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
  102. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
  103. data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
  111. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
  112. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
  113. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
  114. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
  115. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
  116. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
  117. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
  118. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
  119. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
  120. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
  121. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
  122. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
  123. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
  124. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
  125. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
  126. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
  127. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
  128. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
  129. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
  130. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
  131. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
  132. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
  133. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
  134. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
  135. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
  136. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
  137. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
  138. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
  139. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
  140. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
  141. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
  142. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
  143. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
  144. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
  145. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
  146. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
  147. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
  148. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
  149. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
  150. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
  151. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
  152. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
  153. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
  154. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
  155. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
  156. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
  157. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
  158. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
  159. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
  160. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
  161. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
  162. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
  163. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
  164. data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
  165. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
  166. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
  167. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
  168. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
  169. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
  170. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  171. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
  172. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
  173. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
  174. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
  175. data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
  176. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
  177. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
  178. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
  179. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
  180. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
  181. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
  182. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
  183. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
  184. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
  185. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
  186. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
  187. data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
  188. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
  189. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
  190. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
  191. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
  192. data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
  193. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
  194. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
  195. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
  196. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
  197. data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
  198. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
  199. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
  200. data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
  201. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
  202. data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
  203. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
  204. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
  205. data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
  206. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
  207. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
  208. data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
  209. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
  210. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
  211. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
  212. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
  213. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
  214. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
  215. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
  216. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
  217. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
  218. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
  219. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
  220. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
  221. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
  222. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
  223. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
  224. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
  225. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
  226. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
  227. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
  228. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
  229. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
  230. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
  231. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
  232. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
  233. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
  234. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
  235. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
  236. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
  237. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
  238. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
  239. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
  240. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
  241. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
  242. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
  243. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
  244. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
  245. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
  246. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
  247. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
  248. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
  249. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
  250. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
  251. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
  252. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
  253. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
  254. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
  255. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
  256. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
  257. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
  258. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
  259. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
  260. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
  261. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
  262. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
  263. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  264. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
  265. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
  266. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
  267. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
  268. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
  269. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
  270. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
  271. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
  272. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
  273. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
  274. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
  275. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
  276. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
  277. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
  278. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
  279. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
  280. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
  281. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
  282. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
  283. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
  284. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
  285. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
  286. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
  287. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
  288. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
  289. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
  290. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
  291. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
  292. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
  293. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
  294. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
  295. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
  296. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
  297. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
  298. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
  299. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
  300. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
  301. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
  302. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
  303. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
  304. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
  305. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
  306. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
  307. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
  308. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
  309. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
  310. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
  311. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
  312. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
  313. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
  314. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
  315. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
  316. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
  317. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
  318. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
  319. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
  320. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
  321. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
  322. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
  323. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
  324. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
  325. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
  326. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
  327. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
  328. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
  329. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
  330. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
  331. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
  332. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
  333. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
  334. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
  335. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
  336. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
  337. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
  338. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
  339. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
  340. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
  341. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
  342. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
  343. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
  344. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
  345. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
  346. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
  347. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
  348. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
  349. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
  350. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
  351. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
  352. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
  353. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
  354. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
  355. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
  356. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
  357. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
  358. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
  359. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
  360. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
  361. data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
  362. data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
  363. data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
  364. data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
  365. data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
  366. data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
  367. data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
  368. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
  369. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
  370. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
  371. data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
  372. data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
  373. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
  374. data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
  375. data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
  376. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
  377. data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
  378. data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
  379. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
  380. data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
  381. data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
  382. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
  383. data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
  384. data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
  385. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
  386. data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
  387. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
  388. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
  389. data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
  390. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
  391. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
  392. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
  393. data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
  394. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
  395. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
  396. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
  397. data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
  398. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
  399. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
  400. data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
  401. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
  402. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
  403. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
  404. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
  405. data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
  406. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
  407. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
  408. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
  409. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
  410. data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
  411. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
  412. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
  413. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
  414. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
  415. data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
  416. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
  417. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
  418. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
  419. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
  420. data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
  421. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
  422. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
  423. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
  424. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
  425. data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
  426. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
  427. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
  428. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
  429. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
  430. data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
  431. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
  432. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
  433. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
  434. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
  435. data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
  436. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
  437. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
  438. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
  439. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
  440. data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
  441. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
  442. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
  443. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
  444. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
  445. data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
  446. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
  447. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
  448. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
  449. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
  450. data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
  451. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
  452. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
  453. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
  454. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
  455. data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
  456. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
  457. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
  458. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
  459. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
  460. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
  461. data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
  462. data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
  463. data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
  464. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
  465. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
  466. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
  467. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
  468. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
  469. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
  470. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
  471. data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
  472. data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
  473. data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
  474. data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
  475. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
  476. data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
  477. data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
  478. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
  479. data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
  480. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
  481. data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
  482. data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
  483. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
  484. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
  485. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
  486. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
  487. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
  488. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
  489. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
  490. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
  491. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
  492. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
  493. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
  494. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
  495. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
  496. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
  497. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
  498. data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
  499. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
  500. data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
  501. data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
  502. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
  503. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
  504. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
  505. data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
  506. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
  507. data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
  508. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
  509. data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
  510. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
  511. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
  512. data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
  513. data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
  514. data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
  515. data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
  516. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
  517. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
  518. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
  519. data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
  520. data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
  521. data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
  522. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
  523. data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
  524. data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
  525. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
  526. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
  527. data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
  528. data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
  529. data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
  530. data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
  531. data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
  532. data/lib/openstudio-standards/standards/standard.rb +2 -1
  533. data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
  534. data/lib/openstudio-standards/utilities/logging.rb +6 -0
  535. data/lib/openstudio-standards/utilities/simulation.rb +30 -14
  536. data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
  537. data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
  538. data/lib/openstudio-standards/version.rb +2 -2
  539. data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
  540. data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
  541. data/lib/openstudio-standards.rb +9 -0
  542. metadata +106 -205
  543. data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
  544. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
  545. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
  546. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
  547. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
  548. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
  549. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
  550. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
  551. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
  552. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
  553. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
  554. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
  555. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
  556. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
  557. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
  558. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
  559. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
  560. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
  561. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
  562. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
  563. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
  564. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
  565. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
  566. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
  567. data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
  568. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
  569. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
  570. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
  571. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
  572. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
  573. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
  574. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
  575. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
  576. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
  577. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
  578. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
  579. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
  580. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
  581. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
  582. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
  583. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
  584. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
  585. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
  586. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
  587. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
  588. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
  589. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
  590. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
  591. data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
  592. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
  593. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
  594. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
  595. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
  596. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
  597. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
  598. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
  599. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
  600. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
  601. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
  602. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
  603. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
  604. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
  605. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
  606. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
  607. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
  608. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
  609. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
  610. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
  611. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
  612. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
  613. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
  614. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
  615. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
  616. data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
  617. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
  618. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
  619. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
  620. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
  621. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
  622. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
  623. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
  624. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
  625. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
  626. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
  627. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
  628. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
  629. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
  630. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
  631. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
  632. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
  633. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
  634. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
  635. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
  636. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
  637. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
  638. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
  639. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
  640. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
  641. data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
  642. data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
@@ -91,284 +91,11 @@
91
91
  {
92
92
  "template": "DOE Ref 1980-2004",
93
93
  "building_type": "College",
94
- "space_type": "College - Conference",
95
- "lighting_standard": "DOE Ref 1980-2004",
96
- "lighting_primary_space_type": "Conference",
97
- "lighting_secondary_space_type": "General",
98
- "lighting_per_area": 1.84,
99
- "rcr_threshold": null,
100
- "lighting_per_person": null,
101
- "additional_lighting_per_area": null,
102
- "lighting_fraction_to_return_air": null,
103
- "lighting_fraction_radiant": null,
104
- "lighting_fraction_visible": null,
105
- "lighting_fraction_replaceable": null,
106
- "lpd_fraction_linear_fluorescent": null,
107
- "lpd_fraction_compact_fluorescent": null,
108
- "lpd_fraction_high_bay": null,
109
- "lpd_fraction_specialty_lighting": null,
110
- "lpd_fraction_exit_lighting": null,
111
- "lighting_schedule": "College BLDG_LIGHT_SCH",
112
- "compact_fluorescent_lighting_schedule": null,
113
- "high_bay_lighting_schedule": null,
114
- "specialty_lighting_schedule": null,
115
- "exit_lighting_schedule": null,
116
- "target_illuminance_setpoint": null,
117
- "psa_nongeometry_fraction": null,
118
- "ssa_nongeometry_fraction": null,
119
- "notes": null,
120
- "manual_continuous_dimming": null,
121
- "programmable_multilevel_dimming": null,
122
- "multilevel_occupancy_sensors": null,
123
- "occupancy_sensors": null,
124
- "occupancy_sensors_with_personal_continuous_dimming": null,
125
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
126
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
127
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
128
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
129
- },
130
- {
131
- "template": "DOE Ref 1980-2004",
132
- "building_type": "College",
133
- "space_type": "College - Corridor",
134
- "lighting_standard": "DOE Ref 1980-2004",
135
- "lighting_primary_space_type": "Corridor",
136
- "lighting_secondary_space_type": "General",
137
- "lighting_per_area": 0.8,
138
- "rcr_threshold": null,
139
- "lighting_per_person": null,
140
- "additional_lighting_per_area": null,
141
- "lighting_fraction_to_return_air": null,
142
- "lighting_fraction_radiant": null,
143
- "lighting_fraction_visible": null,
144
- "lighting_fraction_replaceable": null,
145
- "lpd_fraction_linear_fluorescent": null,
146
- "lpd_fraction_compact_fluorescent": null,
147
- "lpd_fraction_high_bay": null,
148
- "lpd_fraction_specialty_lighting": null,
149
- "lpd_fraction_exit_lighting": null,
150
- "lighting_schedule": "College BLDG_LIGHT_SCH",
151
- "compact_fluorescent_lighting_schedule": null,
152
- "high_bay_lighting_schedule": null,
153
- "specialty_lighting_schedule": null,
154
- "exit_lighting_schedule": null,
155
- "target_illuminance_setpoint": null,
156
- "psa_nongeometry_fraction": null,
157
- "ssa_nongeometry_fraction": null,
158
- "notes": null,
159
- "manual_continuous_dimming": null,
160
- "programmable_multilevel_dimming": null,
161
- "multilevel_occupancy_sensors": null,
162
- "occupancy_sensors": null,
163
- "occupancy_sensors_with_personal_continuous_dimming": null,
164
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
165
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
166
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
167
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
168
- },
169
- {
170
- "template": "DOE Ref 1980-2004",
171
- "building_type": "College",
172
- "space_type": "College - Elevator Shaft",
173
- "lighting_standard": "DOE Ref 1980-2004",
174
- "lighting_primary_space_type": "ElevatorCore",
175
- "lighting_secondary_space_type": null,
176
- "lighting_per_area": null,
177
- "rcr_threshold": null,
178
- "lighting_per_person": null,
179
- "additional_lighting_per_area": null,
180
- "lighting_fraction_to_return_air": null,
181
- "lighting_fraction_radiant": null,
182
- "lighting_fraction_visible": null,
183
- "lighting_fraction_replaceable": null,
184
- "lpd_fraction_linear_fluorescent": null,
185
- "lpd_fraction_compact_fluorescent": null,
186
- "lpd_fraction_high_bay": null,
187
- "lpd_fraction_specialty_lighting": null,
188
- "lpd_fraction_exit_lighting": null,
189
- "lighting_schedule": "College ELEV_LIGHT_FAN_SCH_24_7",
190
- "compact_fluorescent_lighting_schedule": null,
191
- "high_bay_lighting_schedule": null,
192
- "specialty_lighting_schedule": null,
193
- "exit_lighting_schedule": null,
194
- "target_illuminance_setpoint": null,
195
- "psa_nongeometry_fraction": null,
196
- "ssa_nongeometry_fraction": null,
197
- "notes": null,
198
- "manual_continuous_dimming": null,
199
- "programmable_multilevel_dimming": null,
200
- "multilevel_occupancy_sensors": null,
201
- "occupancy_sensors": null,
202
- "occupancy_sensors_with_personal_continuous_dimming": null,
203
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
204
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
205
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
206
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
207
- },
208
- {
209
- "template": "DOE Ref 1980-2004",
210
- "building_type": "College",
211
- "space_type": "College - Entrance Lobby",
212
- "lighting_standard": "DOE Ref 1980-2004",
213
- "lighting_primary_space_type": "Lobby - elevator",
214
- "lighting_secondary_space_type": "General",
215
- "lighting_per_area": null,
216
- "rcr_threshold": null,
217
- "lighting_per_person": null,
218
- "additional_lighting_per_area": null,
219
- "lighting_fraction_to_return_air": null,
220
- "lighting_fraction_radiant": null,
221
- "lighting_fraction_visible": null,
222
- "lighting_fraction_replaceable": null,
223
- "lpd_fraction_linear_fluorescent": null,
224
- "lpd_fraction_compact_fluorescent": null,
225
- "lpd_fraction_high_bay": null,
226
- "lpd_fraction_specialty_lighting": null,
227
- "lpd_fraction_exit_lighting": null,
228
- "lighting_schedule": "College BLDG_LIGHT_SCH",
229
- "compact_fluorescent_lighting_schedule": null,
230
- "high_bay_lighting_schedule": null,
231
- "specialty_lighting_schedule": null,
232
- "exit_lighting_schedule": null,
233
- "target_illuminance_setpoint": null,
234
- "psa_nongeometry_fraction": null,
235
- "ssa_nongeometry_fraction": null,
236
- "notes": null,
237
- "manual_continuous_dimming": null,
238
- "programmable_multilevel_dimming": null,
239
- "multilevel_occupancy_sensors": null,
240
- "occupancy_sensors": null,
241
- "occupancy_sensors_with_personal_continuous_dimming": null,
242
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
243
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
244
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
245
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
246
- },
247
- {
248
- "template": "DOE Ref 1980-2004",
249
- "building_type": "College",
250
- "space_type": "College - Lounge",
251
- "lighting_standard": "DOE Ref 1980-2004",
252
- "lighting_primary_space_type": "Lounge",
253
- "lighting_secondary_space_type": "General",
254
- "lighting_per_area": null,
255
- "rcr_threshold": null,
256
- "lighting_per_person": null,
257
- "additional_lighting_per_area": null,
258
- "lighting_fraction_to_return_air": null,
259
- "lighting_fraction_radiant": null,
260
- "lighting_fraction_visible": null,
261
- "lighting_fraction_replaceable": null,
262
- "lpd_fraction_linear_fluorescent": null,
263
- "lpd_fraction_compact_fluorescent": null,
264
- "lpd_fraction_high_bay": null,
265
- "lpd_fraction_specialty_lighting": null,
266
- "lpd_fraction_exit_lighting": null,
267
- "lighting_schedule": "College BLDG_LIGHT_SCH",
268
- "compact_fluorescent_lighting_schedule": null,
269
- "high_bay_lighting_schedule": null,
270
- "specialty_lighting_schedule": null,
271
- "exit_lighting_schedule": null,
272
- "target_illuminance_setpoint": null,
273
- "psa_nongeometry_fraction": null,
274
- "ssa_nongeometry_fraction": null,
275
- "notes": null,
276
- "manual_continuous_dimming": null,
277
- "programmable_multilevel_dimming": null,
278
- "multilevel_occupancy_sensors": null,
279
- "occupancy_sensors": null,
280
- "occupancy_sensors_with_personal_continuous_dimming": null,
281
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
282
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
283
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
284
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
285
- },
286
- {
287
- "template": "DOE Ref 1980-2004",
288
- "building_type": "College",
289
- "space_type": "College - Office",
290
- "lighting_standard": "DOE Ref 1980-2004",
291
- "lighting_primary_space_type": "Office - enclosed",
292
- "lighting_secondary_space_type": "General",
293
- "lighting_per_area": 1.8,
294
- "rcr_threshold": null,
295
- "lighting_per_person": null,
296
- "additional_lighting_per_area": null,
297
- "lighting_fraction_to_return_air": null,
298
- "lighting_fraction_radiant": null,
299
- "lighting_fraction_visible": null,
300
- "lighting_fraction_replaceable": null,
301
- "lpd_fraction_linear_fluorescent": null,
302
- "lpd_fraction_compact_fluorescent": null,
303
- "lpd_fraction_high_bay": null,
304
- "lpd_fraction_specialty_lighting": null,
305
- "lpd_fraction_exit_lighting": null,
306
- "lighting_schedule": "College BLDG_LIGHT_SCH",
307
- "compact_fluorescent_lighting_schedule": null,
308
- "high_bay_lighting_schedule": null,
309
- "specialty_lighting_schedule": null,
310
- "exit_lighting_schedule": null,
311
- "target_illuminance_setpoint": null,
312
- "psa_nongeometry_fraction": null,
313
- "ssa_nongeometry_fraction": null,
314
- "notes": null,
315
- "manual_continuous_dimming": null,
316
- "programmable_multilevel_dimming": null,
317
- "multilevel_occupancy_sensors": null,
318
- "occupancy_sensors": null,
319
- "occupancy_sensors_with_personal_continuous_dimming": null,
320
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
321
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
322
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
323
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
324
- },
325
- {
326
- "template": "DOE Ref 1980-2004",
327
- "building_type": "College",
328
- "space_type": "College - Restroom",
329
- "lighting_standard": "DOE Ref 1980-2004",
330
- "lighting_primary_space_type": "Restroom",
331
- "lighting_secondary_space_type": "General",
332
- "lighting_per_area": 0.8,
333
- "rcr_threshold": null,
334
- "lighting_per_person": null,
335
- "additional_lighting_per_area": null,
336
- "lighting_fraction_to_return_air": null,
337
- "lighting_fraction_radiant": null,
338
- "lighting_fraction_visible": null,
339
- "lighting_fraction_replaceable": null,
340
- "lpd_fraction_linear_fluorescent": null,
341
- "lpd_fraction_compact_fluorescent": null,
342
- "lpd_fraction_high_bay": null,
343
- "lpd_fraction_specialty_lighting": null,
344
- "lpd_fraction_exit_lighting": null,
345
- "lighting_schedule": "College BLDG_LIGHT_SCH",
346
- "compact_fluorescent_lighting_schedule": null,
347
- "high_bay_lighting_schedule": null,
348
- "specialty_lighting_schedule": null,
349
- "exit_lighting_schedule": null,
350
- "target_illuminance_setpoint": null,
351
- "psa_nongeometry_fraction": null,
352
- "ssa_nongeometry_fraction": null,
353
- "notes": null,
354
- "manual_continuous_dimming": null,
355
- "programmable_multilevel_dimming": null,
356
- "multilevel_occupancy_sensors": null,
357
- "occupancy_sensors": null,
358
- "occupancy_sensors_with_personal_continuous_dimming": null,
359
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
360
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
361
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
362
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
363
- },
364
- {
365
- "template": "DOE Ref 1980-2004",
366
- "building_type": "College",
367
- "space_type": "College - Utility",
94
+ "space_type": "College - Art Classroom",
368
95
  "lighting_standard": "DOE Ref 1980-2004",
369
- "lighting_primary_space_type": "Electrical/Mechanical",
96
+ "lighting_primary_space_type": "Classroom/lecture/training",
370
97
  "lighting_secondary_space_type": "General",
371
- "lighting_per_area": 1.5,
98
+ "lighting_per_area": 1.6,
372
99
  "rcr_threshold": null,
373
100
  "lighting_per_person": null,
374
101
  "additional_lighting_per_area": null,
@@ -390,66 +117,27 @@
390
117
  "psa_nongeometry_fraction": null,
391
118
  "ssa_nongeometry_fraction": null,
392
119
  "notes": null,
393
- "gas_equipment_per_area": 532.0,
394
- "gas_equipment_fraction_latent": 0.1,
395
- "gas_equipment_fraction_radiant": 0.2,
396
- "gas_equipment_fraction_lost": 0.7,
397
- "gas_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
398
- "electric_equipment_per_area": 70.29,
399
- "electric_equipment_fraction_latent": 0.2,
400
- "electric_equipment_fraction_radiant": 0.3,
401
- "electric_equipment_fraction_lost": 0.25,
120
+ "gas_equipment_per_area": null,
121
+ "gas_equipment_fraction_latent": null,
122
+ "gas_equipment_fraction_radiant": null,
123
+ "gas_equipment_fraction_lost": null,
124
+ "gas_equipment_schedule": null,
125
+ "electric_equipment_per_area": 0.93,
126
+ "electric_equipment_fraction_latent": 0.0,
127
+ "electric_equipment_fraction_radiant": 0.5,
128
+ "electric_equipment_fraction_lost": 0.0,
402
129
  "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
403
130
  "additional_electric_equipment_schedule": null,
404
131
  "additional_gas_equipment_schedule": null,
405
- "manual_continuous_dimming": null,
406
- "programmable_multilevel_dimming": null,
407
- "multilevel_occupancy_sensors": null,
408
- "occupancy_sensors": null,
409
- "occupancy_sensors_with_personal_continuous_dimming": null,
410
- "automatic_multilevel_switching_in_primary_sidelighted_areas": null,
411
- "automatic_continuous_daylight_dimming_in_primary_sidelighted_areas": null,
412
- "automatic_continuous_daylight_dimming_in_secondary_sidelighted_areas": null,
413
- "automatic_continuous_daylight_dimming_in_daylighted_areas_under_skylights": null
414
- },
415
- {
416
- "template": "DOE Ref 1980-2004",
417
- "building_type": "College",
418
- "space_type": "College - Art Classroom",
419
- "lighting_standard": "DOE Ref 1980-2004",
420
- "lighting_primary_space_type": "Classroom/lecture/training",
421
- "lighting_secondary_space_type": "General",
422
- "lighting_per_area": null,
423
- "rcr_threshold": null,
424
- "lighting_per_person": null,
425
- "additional_lighting_per_area": null,
426
- "lighting_fraction_to_return_air": null,
427
- "lighting_fraction_radiant": null,
428
- "lighting_fraction_visible": null,
429
- "lighting_fraction_replaceable": null,
430
- "lpd_fraction_linear_fluorescent": null,
431
- "lpd_fraction_compact_fluorescent": null,
432
- "lpd_fraction_high_bay": null,
433
- "lpd_fraction_specialty_lighting": null,
434
- "lpd_fraction_exit_lighting": null,
435
- "lighting_schedule": "College BLDG_LIGHT_SCH",
436
- "compact_fluorescent_lighting_schedule": null,
437
- "high_bay_lighting_schedule": null,
438
- "specialty_lighting_schedule": null,
439
- "exit_lighting_schedule": null,
440
- "target_illuminance_setpoint": null,
441
- "psa_nongeometry_fraction": null,
442
- "ssa_nongeometry_fraction": null,
443
- "notes": null,
444
132
  "occupancy_per_area": null,
445
133
  "occupancy_schedule": "College BLDG_OCC_SCH",
446
134
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
447
135
  "is_residential": null,
448
136
  "ventilation_standard": "ASHRAE 62.1-1999",
449
- "ventilation_primary_space_type": null,
450
- "ventilation_secondary_space_type": null,
451
- "ventilation_per_area": null,
452
- "ventilation_per_person": null,
137
+ "ventilation_primary_space_type": "Education",
138
+ "ventilation_secondary_space_type": "Classroom",
139
+ "ventilation_per_area": 0.0,
140
+ "ventilation_per_person": 15.0,
453
141
  "ventilation_air_changes": null,
454
142
  "minimum_total_air_changes": null,
455
143
  "infiltration_per_exterior_area": null,
@@ -495,7 +183,7 @@
495
183
  "lighting_standard": "DOE Ref 1980-2004",
496
184
  "lighting_primary_space_type": "Classroom",
497
185
  "lighting_secondary_space_type": "General",
498
- "lighting_per_area": null,
186
+ "lighting_per_area": 1.6,
499
187
  "rcr_threshold": null,
500
188
  "lighting_per_person": null,
501
189
  "additional_lighting_per_area": null,
@@ -517,15 +205,27 @@
517
205
  "psa_nongeometry_fraction": null,
518
206
  "ssa_nongeometry_fraction": null,
519
207
  "notes": null,
208
+ "gas_equipment_per_area": null,
209
+ "gas_equipment_fraction_latent": null,
210
+ "gas_equipment_fraction_radiant": null,
211
+ "gas_equipment_fraction_lost": null,
212
+ "gas_equipment_schedule": null,
213
+ "electric_equipment_per_area": 0.93,
214
+ "electric_equipment_fraction_latent": 0.0,
215
+ "electric_equipment_fraction_radiant": 0.5,
216
+ "electric_equipment_fraction_lost": 0.0,
217
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
218
+ "additional_electric_equipment_schedule": null,
219
+ "additional_gas_equipment_schedule": null,
520
220
  "occupancy_per_area": 65.0,
521
221
  "occupancy_schedule": "College BLDG_OCC_SCH",
522
222
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
523
223
  "is_residential": null,
524
224
  "ventilation_standard": "ASHRAE 62.1-1999",
525
- "ventilation_primary_space_type": null,
526
- "ventilation_secondary_space_type": null,
527
- "ventilation_per_area": null,
528
- "ventilation_per_person": null,
225
+ "ventilation_primary_space_type": "Education",
226
+ "ventilation_secondary_space_type": "Classroom",
227
+ "ventilation_per_area": 0.0,
228
+ "ventilation_per_person": 15.0,
529
229
  "ventilation_air_changes": null,
530
230
  "minimum_total_air_changes": null,
531
231
  "infiltration_per_exterior_area": null,
@@ -568,16 +268,52 @@
568
268
  "template": "DOE Ref 1980-2004",
569
269
  "building_type": "College",
570
270
  "space_type": "College - Conference",
271
+ "lighting_standard": "DOE Ref 1980-2004",
272
+ "lighting_primary_space_type": "Conference",
273
+ "lighting_secondary_space_type": "General",
274
+ "lighting_per_area": 1.5,
275
+ "rcr_threshold": null,
276
+ "lighting_per_person": null,
277
+ "additional_lighting_per_area": null,
278
+ "lighting_fraction_to_return_air": null,
279
+ "lighting_fraction_radiant": null,
280
+ "lighting_fraction_visible": null,
281
+ "lighting_fraction_replaceable": null,
282
+ "lpd_fraction_linear_fluorescent": null,
283
+ "lpd_fraction_compact_fluorescent": null,
284
+ "lpd_fraction_high_bay": null,
285
+ "lpd_fraction_specialty_lighting": null,
286
+ "lpd_fraction_exit_lighting": null,
287
+ "lighting_schedule": "College BLDG_LIGHT_SCH",
288
+ "compact_fluorescent_lighting_schedule": null,
289
+ "high_bay_lighting_schedule": null,
290
+ "specialty_lighting_schedule": null,
291
+ "exit_lighting_schedule": null,
292
+ "target_illuminance_setpoint": null,
293
+ "psa_nongeometry_fraction": null,
294
+ "ssa_nongeometry_fraction": null,
295
+ "notes": null,
296
+ "gas_equipment_per_area": null,
297
+ "gas_equipment_fraction_latent": null,
298
+ "gas_equipment_fraction_radiant": null,
299
+ "gas_equipment_fraction_lost": null,
300
+ "gas_equipment_schedule": null,
301
+ "electric_equipment_per_area": 1.33,
302
+ "electric_equipment_fraction_latent": 0.0,
303
+ "electric_equipment_fraction_radiant": 0.5,
304
+ "electric_equipment_fraction_lost": 0.0,
305
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
306
+ "additional_electric_equipment_schedule": null,
307
+ "additional_gas_equipment_schedule": null,
571
308
  "occupancy_per_area": 50.0,
572
309
  "occupancy_schedule": "College BLDG_OCC_SCH",
573
310
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
574
311
  "is_residential": null,
575
- "notes": null,
576
312
  "ventilation_standard": "ASHRAE 62.1-1999",
577
- "ventilation_primary_space_type": null,
578
- "ventilation_secondary_space_type": null,
579
- "ventilation_per_area": 0.0,
580
- "ventilation_per_person": 7.0,
313
+ "ventilation_primary_space_type": "Offices",
314
+ "ventilation_secondary_space_type": "Conference rooms",
315
+ "ventilation_per_area": 20.0,
316
+ "ventilation_per_person": 20.0,
581
317
  "ventilation_air_changes": null,
582
318
  "minimum_total_air_changes": null,
583
319
  "infiltration_per_exterior_area": null,
@@ -611,15 +347,51 @@
611
347
  "template": "DOE Ref 1980-2004",
612
348
  "building_type": "College",
613
349
  "space_type": "College - Corridor",
350
+ "lighting_standard": "DOE Ref 1980-2004",
351
+ "lighting_primary_space_type": "Corridor",
352
+ "lighting_secondary_space_type": "General",
353
+ "lighting_per_area": 0.7,
354
+ "rcr_threshold": null,
355
+ "lighting_per_person": null,
356
+ "additional_lighting_per_area": null,
357
+ "lighting_fraction_to_return_air": null,
358
+ "lighting_fraction_radiant": null,
359
+ "lighting_fraction_visible": null,
360
+ "lighting_fraction_replaceable": null,
361
+ "lpd_fraction_linear_fluorescent": null,
362
+ "lpd_fraction_compact_fluorescent": null,
363
+ "lpd_fraction_high_bay": null,
364
+ "lpd_fraction_specialty_lighting": null,
365
+ "lpd_fraction_exit_lighting": null,
366
+ "lighting_schedule": "College BLDG_LIGHT_SCH",
367
+ "compact_fluorescent_lighting_schedule": null,
368
+ "high_bay_lighting_schedule": null,
369
+ "specialty_lighting_schedule": null,
370
+ "exit_lighting_schedule": null,
371
+ "target_illuminance_setpoint": null,
372
+ "psa_nongeometry_fraction": null,
373
+ "ssa_nongeometry_fraction": null,
374
+ "notes": null,
375
+ "gas_equipment_per_area": null,
376
+ "gas_equipment_fraction_latent": null,
377
+ "gas_equipment_fraction_radiant": null,
378
+ "gas_equipment_fraction_lost": null,
379
+ "gas_equipment_schedule": null,
380
+ "electric_equipment_per_area": 0.37,
381
+ "electric_equipment_fraction_latent": 0.0,
382
+ "electric_equipment_fraction_radiant": 0.5,
383
+ "electric_equipment_fraction_lost": 0.0,
384
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
385
+ "additional_electric_equipment_schedule": null,
386
+ "additional_gas_equipment_schedule": null,
614
387
  "occupancy_per_area": null,
615
388
  "occupancy_schedule": null,
616
389
  "occupancy_activity_schedule": null,
617
390
  "is_residential": null,
618
- "notes": null,
619
391
  "ventilation_standard": "ASHRAE 62.1-1999",
620
- "ventilation_primary_space_type": null,
621
- "ventilation_secondary_space_type": null,
622
- "ventilation_per_area": 0.02,
392
+ "ventilation_primary_space_type": "Public Spaces",
393
+ "ventilation_secondary_space_type": "Corridors and utilities",
394
+ "ventilation_per_area": 0.05,
623
395
  "ventilation_per_person": 0.0,
624
396
  "ventilation_air_changes": null,
625
397
  "minimum_total_air_changes": null,
@@ -654,14 +426,38 @@
654
426
  "template": "DOE Ref 1980-2004",
655
427
  "building_type": "College",
656
428
  "space_type": "College - Elevator Shaft",
429
+ "lighting_standard": "DOE Ref 1980-2004",
430
+ "lighting_primary_space_type": "ElevatorCore",
431
+ "lighting_secondary_space_type": null,
432
+ "lighting_per_area": 0.0,
433
+ "rcr_threshold": null,
434
+ "lighting_per_person": null,
435
+ "additional_lighting_per_area": null,
436
+ "lighting_fraction_to_return_air": null,
437
+ "lighting_fraction_radiant": null,
438
+ "lighting_fraction_visible": null,
439
+ "lighting_fraction_replaceable": null,
440
+ "lpd_fraction_linear_fluorescent": null,
441
+ "lpd_fraction_compact_fluorescent": null,
442
+ "lpd_fraction_high_bay": null,
443
+ "lpd_fraction_specialty_lighting": null,
444
+ "lpd_fraction_exit_lighting": null,
445
+ "lighting_schedule": "College ELEV_LIGHT_FAN_SCH_24_7",
446
+ "compact_fluorescent_lighting_schedule": null,
447
+ "high_bay_lighting_schedule": null,
448
+ "specialty_lighting_schedule": null,
449
+ "exit_lighting_schedule": null,
450
+ "target_illuminance_setpoint": null,
451
+ "psa_nongeometry_fraction": null,
452
+ "ssa_nongeometry_fraction": null,
453
+ "notes": null,
657
454
  "occupancy_per_area": null,
658
455
  "occupancy_schedule": null,
659
456
  "occupancy_activity_schedule": null,
660
457
  "is_residential": null,
661
- "notes": null,
662
458
  "ventilation_standard": "ASHRAE 62.1-1999",
663
- "ventilation_primary_space_type": null,
664
- "ventilation_secondary_space_type": null,
459
+ "ventilation_primary_space_type": "Public Spaces",
460
+ "ventilation_secondary_space_type": "Elevators",
665
461
  "ventilation_per_area": 1.0,
666
462
  "ventilation_per_person": 0.0,
667
463
  "ventilation_air_changes": null,
@@ -697,16 +493,52 @@
697
493
  "template": "DOE Ref 1980-2004",
698
494
  "building_type": "College",
699
495
  "space_type": "College - Entrance Lobby",
496
+ "lighting_standard": "DOE Ref 1980-2004",
497
+ "lighting_primary_space_type": "Lobby",
498
+ "lighting_secondary_space_type": "General",
499
+ "lighting_per_area": 1.8,
500
+ "rcr_threshold": null,
501
+ "lighting_per_person": null,
502
+ "additional_lighting_per_area": null,
503
+ "lighting_fraction_to_return_air": null,
504
+ "lighting_fraction_radiant": null,
505
+ "lighting_fraction_visible": null,
506
+ "lighting_fraction_replaceable": null,
507
+ "lpd_fraction_linear_fluorescent": null,
508
+ "lpd_fraction_compact_fluorescent": null,
509
+ "lpd_fraction_high_bay": null,
510
+ "lpd_fraction_specialty_lighting": null,
511
+ "lpd_fraction_exit_lighting": null,
512
+ "lighting_schedule": "College BLDG_LIGHT_SCH",
513
+ "compact_fluorescent_lighting_schedule": null,
514
+ "high_bay_lighting_schedule": null,
515
+ "specialty_lighting_schedule": null,
516
+ "exit_lighting_schedule": null,
517
+ "target_illuminance_setpoint": null,
518
+ "psa_nongeometry_fraction": null,
519
+ "ssa_nongeometry_fraction": null,
520
+ "notes": null,
521
+ "gas_equipment_per_area": null,
522
+ "gas_equipment_fraction_latent": null,
523
+ "gas_equipment_fraction_radiant": null,
524
+ "gas_equipment_fraction_lost": null,
525
+ "gas_equipment_schedule": null,
526
+ "electric_equipment_per_area": 0.37,
527
+ "electric_equipment_fraction_latent": 0.0,
528
+ "electric_equipment_fraction_radiant": 0.5,
529
+ "electric_equipment_fraction_lost": 0.0,
530
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
531
+ "additional_electric_equipment_schedule": null,
532
+ "additional_gas_equipment_schedule": null,
700
533
  "occupancy_per_area": 10.0,
701
534
  "occupancy_schedule": "College BLDG_OCC_SCH",
702
535
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
703
536
  "is_residential": null,
704
- "notes": null,
705
537
  "ventilation_standard": "ASHRAE 62.1-1999",
706
- "ventilation_primary_space_type": null,
707
- "ventilation_secondary_space_type": null,
708
- "ventilation_per_area": null,
709
- "ventilation_per_person": null,
538
+ "ventilation_primary_space_type": "Offices",
539
+ "ventilation_secondary_space_type": "Reception areas",
540
+ "ventilation_per_area": 0.0,
541
+ "ventilation_per_person": 15.0,
710
542
  "ventilation_air_changes": null,
711
543
  "minimum_total_air_changes": null,
712
544
  "infiltration_per_exterior_area": null,
@@ -743,7 +575,7 @@
743
575
  "lighting_standard": "DOE Ref 1980-2004",
744
576
  "lighting_primary_space_type": "Lab",
745
577
  "lighting_secondary_space_type": "General",
746
- "lighting_per_area": null,
578
+ "lighting_per_area": 1.4,
747
579
  "rcr_threshold": null,
748
580
  "lighting_per_person": null,
749
581
  "additional_lighting_per_area": null,
@@ -765,15 +597,27 @@
765
597
  "psa_nongeometry_fraction": null,
766
598
  "ssa_nongeometry_fraction": null,
767
599
  "notes": null,
600
+ "gas_equipment_per_area": null,
601
+ "gas_equipment_fraction_latent": null,
602
+ "gas_equipment_fraction_radiant": null,
603
+ "gas_equipment_fraction_lost": null,
604
+ "gas_equipment_schedule": null,
605
+ "electric_equipment_per_area": 4.0,
606
+ "electric_equipment_fraction_latent": 0.0,
607
+ "electric_equipment_fraction_radiant": 0.5,
608
+ "electric_equipment_fraction_lost": 0.0,
609
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
610
+ "additional_electric_equipment_schedule": null,
611
+ "additional_gas_equipment_schedule": null,
768
612
  "occupancy_per_area": 25.0,
769
613
  "occupancy_schedule": "College BLDG_OCC_SCH",
770
614
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
771
615
  "is_residential": null,
772
616
  "ventilation_standard": "ASHRAE 62.1-1999",
773
- "ventilation_primary_space_type": null,
617
+ "ventilation_primary_space_type": "college/university-laboratories",
774
618
  "ventilation_secondary_space_type": null,
775
- "ventilation_per_area": null,
776
- "ventilation_per_person": null,
619
+ "ventilation_per_area": 0.0,
620
+ "ventilation_per_person": 20.0,
777
621
  "ventilation_air_changes": null,
778
622
  "minimum_total_air_changes": null,
779
623
  "infiltration_per_exterior_area": null,
@@ -819,7 +663,7 @@
819
663
  "lighting_standard": "DOE Ref 1980-2004",
820
664
  "lighting_primary_space_type": "Auditorium",
821
665
  "lighting_secondary_space_type": "General",
822
- "lighting_per_area": null,
666
+ "lighting_per_area": 1.4,
823
667
  "rcr_threshold": null,
824
668
  "lighting_per_person": null,
825
669
  "additional_lighting_per_area": null,
@@ -841,15 +685,27 @@
841
685
  "psa_nongeometry_fraction": null,
842
686
  "ssa_nongeometry_fraction": null,
843
687
  "notes": null,
688
+ "gas_equipment_per_area": null,
689
+ "gas_equipment_fraction_latent": null,
690
+ "gas_equipment_fraction_radiant": null,
691
+ "gas_equipment_fraction_lost": null,
692
+ "gas_equipment_schedule": null,
693
+ "electric_equipment_per_area": 0.93,
694
+ "electric_equipment_fraction_latent": 0.0,
695
+ "electric_equipment_fraction_radiant": 0.5,
696
+ "electric_equipment_fraction_lost": 0.0,
697
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
698
+ "additional_electric_equipment_schedule": null,
699
+ "additional_gas_equipment_schedule": null,
844
700
  "occupancy_per_area": 65.0,
845
701
  "occupancy_schedule": "College BLDG_OCC_SCH_Lecture Theater",
846
702
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
847
703
  "is_residential": null,
848
704
  "ventilation_standard": "ASHRAE 62.1-1999",
849
- "ventilation_primary_space_type": null,
850
- "ventilation_secondary_space_type": null,
851
- "ventilation_per_area": null,
852
- "ventilation_per_person": null,
705
+ "ventilation_primary_space_type": "Education",
706
+ "ventilation_secondary_space_type": "Classroom",
707
+ "ventilation_per_area": 0.0,
708
+ "ventilation_per_person": 15.0,
853
709
  "ventilation_air_changes": null,
854
710
  "minimum_total_air_changes": null,
855
711
  "infiltration_per_exterior_area": null,
@@ -892,16 +748,52 @@
892
748
  "template": "DOE Ref 1980-2004",
893
749
  "building_type": "College",
894
750
  "space_type": "College - Lounge",
895
- "occupancy_per_area": null,
896
- "occupancy_schedule": null,
897
- "occupancy_activity_schedule": null,
898
- "is_residential": null,
751
+ "lighting_standard": "DOE Ref 1980-2004",
752
+ "lighting_primary_space_type": "Lounge",
753
+ "lighting_secondary_space_type": "General",
754
+ "lighting_per_area": 1.4,
755
+ "rcr_threshold": null,
756
+ "lighting_per_person": null,
757
+ "additional_lighting_per_area": null,
758
+ "lighting_fraction_to_return_air": null,
759
+ "lighting_fraction_radiant": null,
760
+ "lighting_fraction_visible": null,
761
+ "lighting_fraction_replaceable": null,
762
+ "lpd_fraction_linear_fluorescent": null,
763
+ "lpd_fraction_compact_fluorescent": null,
764
+ "lpd_fraction_high_bay": null,
765
+ "lpd_fraction_specialty_lighting": null,
766
+ "lpd_fraction_exit_lighting": null,
767
+ "lighting_schedule": "College BLDG_LIGHT_SCH",
768
+ "compact_fluorescent_lighting_schedule": null,
769
+ "high_bay_lighting_schedule": null,
770
+ "specialty_lighting_schedule": null,
771
+ "exit_lighting_schedule": null,
772
+ "target_illuminance_setpoint": null,
773
+ "psa_nongeometry_fraction": null,
774
+ "ssa_nongeometry_fraction": null,
899
775
  "notes": null,
776
+ "gas_equipment_per_area": null,
777
+ "gas_equipment_fraction_latent": null,
778
+ "gas_equipment_fraction_radiant": null,
779
+ "gas_equipment_fraction_lost": null,
780
+ "gas_equipment_schedule": null,
781
+ "electric_equipment_per_area": 1.79,
782
+ "electric_equipment_fraction_latent": 0.0,
783
+ "electric_equipment_fraction_radiant": 0.5,
784
+ "electric_equipment_fraction_lost": 0.0,
785
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
786
+ "additional_electric_equipment_schedule": null,
787
+ "additional_gas_equipment_schedule": null,
788
+ "occupancy_per_area": 25.0,
789
+ "occupancy_schedule": "College BLDG_OCC_SCH",
790
+ "occupancy_activity_schedule": "College ACTIVITY_SCH",
791
+ "is_residential": null,
900
792
  "ventilation_standard": "ASHRAE 62.1-1999",
901
- "ventilation_primary_space_type": null,
902
- "ventilation_secondary_space_type": null,
903
- "ventilation_per_area": null,
904
- "ventilation_per_person": null,
793
+ "ventilation_primary_space_type": "Food and Beverage Service",
794
+ "ventilation_secondary_space_type": "Cafeteria, fast food",
795
+ "ventilation_per_area": 0.0,
796
+ "ventilation_per_person": 20.0,
905
797
  "ventilation_air_changes": null,
906
798
  "minimum_total_air_changes": null,
907
799
  "infiltration_per_exterior_area": null,
@@ -938,7 +830,7 @@
938
830
  "lighting_standard": "DOE Ref 1980-2004",
939
831
  "lighting_primary_space_type": "Auditorium",
940
832
  "lighting_secondary_space_type": "General",
941
- "lighting_per_area": 1.9,
833
+ "lighting_per_area": 1.8,
942
834
  "rcr_threshold": null,
943
835
  "lighting_per_person": null,
944
836
  "additional_lighting_per_area": null,
@@ -960,15 +852,27 @@
960
852
  "psa_nongeometry_fraction": null,
961
853
  "ssa_nongeometry_fraction": null,
962
854
  "notes": null,
855
+ "gas_equipment_per_area": null,
856
+ "gas_equipment_fraction_latent": null,
857
+ "gas_equipment_fraction_radiant": null,
858
+ "gas_equipment_fraction_lost": null,
859
+ "gas_equipment_schedule": null,
860
+ "electric_equipment_per_area": 0.93,
861
+ "electric_equipment_fraction_latent": 0.0,
862
+ "electric_equipment_fraction_radiant": 0.5,
863
+ "electric_equipment_fraction_lost": 0.0,
864
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
865
+ "additional_electric_equipment_schedule": null,
866
+ "additional_gas_equipment_schedule": null,
963
867
  "occupancy_per_area": 10.0,
964
868
  "occupancy_schedule": "College BLDG_OCC_SCH_Lecture Theater",
965
869
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
966
870
  "is_residential": null,
967
871
  "ventilation_standard": "ASHRAE 62.1-1999",
968
- "ventilation_primary_space_type": null,
969
- "ventilation_secondary_space_type": null,
872
+ "ventilation_primary_space_type": "Education",
873
+ "ventilation_secondary_space_type": "Libraries",
970
874
  "ventilation_per_area": 0.0,
971
- "ventilation_per_person": 5.0,
875
+ "ventilation_per_person": 15.0,
972
876
  "ventilation_air_changes": null,
973
877
  "minimum_total_air_changes": null,
974
878
  "infiltration_per_exterior_area": null,
@@ -1011,16 +915,52 @@
1011
915
  "template": "DOE Ref 1980-2004",
1012
916
  "building_type": "College",
1013
917
  "space_type": "College - Office",
918
+ "lighting_standard": "DOE Ref 1980-2004",
919
+ "lighting_primary_space_type": "Office - enclosed",
920
+ "lighting_secondary_space_type": "General",
921
+ "lighting_per_area": 1.5,
922
+ "rcr_threshold": null,
923
+ "lighting_per_person": null,
924
+ "additional_lighting_per_area": null,
925
+ "lighting_fraction_to_return_air": null,
926
+ "lighting_fraction_radiant": null,
927
+ "lighting_fraction_visible": null,
928
+ "lighting_fraction_replaceable": null,
929
+ "lpd_fraction_linear_fluorescent": null,
930
+ "lpd_fraction_compact_fluorescent": null,
931
+ "lpd_fraction_high_bay": null,
932
+ "lpd_fraction_specialty_lighting": null,
933
+ "lpd_fraction_exit_lighting": null,
934
+ "lighting_schedule": "College BLDG_LIGHT_SCH",
935
+ "compact_fluorescent_lighting_schedule": null,
936
+ "high_bay_lighting_schedule": null,
937
+ "specialty_lighting_schedule": null,
938
+ "exit_lighting_schedule": null,
939
+ "target_illuminance_setpoint": null,
940
+ "psa_nongeometry_fraction": null,
941
+ "ssa_nongeometry_fraction": null,
942
+ "notes": null,
943
+ "gas_equipment_per_area": null,
944
+ "gas_equipment_fraction_latent": null,
945
+ "gas_equipment_fraction_radiant": null,
946
+ "gas_equipment_fraction_lost": null,
947
+ "gas_equipment_schedule": null,
948
+ "electric_equipment_per_area": 1.0,
949
+ "electric_equipment_fraction_latent": 0.0,
950
+ "electric_equipment_fraction_radiant": 0.5,
951
+ "electric_equipment_fraction_lost": 0.0,
952
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
953
+ "additional_electric_equipment_schedule": null,
954
+ "additional_gas_equipment_schedule": null,
1014
955
  "occupancy_per_area": 5.0,
1015
956
  "occupancy_schedule": "College BLDG_OCC_SCH_Offices",
1016
957
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
1017
958
  "is_residential": null,
1018
- "notes": null,
1019
959
  "ventilation_standard": "ASHRAE 62.1-1999",
1020
- "ventilation_primary_space_type": null,
1021
- "ventilation_secondary_space_type": null,
960
+ "ventilation_primary_space_type": "Offices",
961
+ "ventilation_secondary_space_type": "Office space",
1022
962
  "ventilation_per_area": 0.0,
1023
- "ventilation_per_person": 5.0,
963
+ "ventilation_per_person": 20.0,
1024
964
  "ventilation_air_changes": null,
1025
965
  "minimum_total_air_changes": null,
1026
966
  "infiltration_per_exterior_area": null,
@@ -1054,16 +994,52 @@
1054
994
  "template": "DOE Ref 1980-2004",
1055
995
  "building_type": "College",
1056
996
  "space_type": "College - Restroom",
997
+ "lighting_standard": "DOE Ref 1980-2004",
998
+ "lighting_primary_space_type": "Restroom",
999
+ "lighting_secondary_space_type": "General",
1000
+ "lighting_per_area": 1.0,
1001
+ "rcr_threshold": null,
1002
+ "lighting_per_person": null,
1003
+ "additional_lighting_per_area": null,
1004
+ "lighting_fraction_to_return_air": null,
1005
+ "lighting_fraction_radiant": null,
1006
+ "lighting_fraction_visible": null,
1007
+ "lighting_fraction_replaceable": null,
1008
+ "lpd_fraction_linear_fluorescent": null,
1009
+ "lpd_fraction_compact_fluorescent": null,
1010
+ "lpd_fraction_high_bay": null,
1011
+ "lpd_fraction_specialty_lighting": null,
1012
+ "lpd_fraction_exit_lighting": null,
1013
+ "lighting_schedule": "College BLDG_LIGHT_SCH",
1014
+ "compact_fluorescent_lighting_schedule": null,
1015
+ "high_bay_lighting_schedule": null,
1016
+ "specialty_lighting_schedule": null,
1017
+ "exit_lighting_schedule": null,
1018
+ "target_illuminance_setpoint": null,
1019
+ "psa_nongeometry_fraction": null,
1020
+ "ssa_nongeometry_fraction": null,
1021
+ "notes": null,
1022
+ "gas_equipment_per_area": null,
1023
+ "gas_equipment_fraction_latent": null,
1024
+ "gas_equipment_fraction_radiant": null,
1025
+ "gas_equipment_fraction_lost": null,
1026
+ "gas_equipment_schedule": null,
1027
+ "electric_equipment_per_area": 0.37,
1028
+ "electric_equipment_fraction_latent": 0.0,
1029
+ "electric_equipment_fraction_radiant": 0.5,
1030
+ "electric_equipment_fraction_lost": 0.0,
1031
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
1032
+ "additional_electric_equipment_schedule": null,
1033
+ "additional_gas_equipment_schedule": null,
1057
1034
  "occupancy_per_area": null,
1058
1035
  "occupancy_schedule": null,
1059
1036
  "occupancy_activity_schedule": null,
1060
1037
  "is_residential": null,
1061
- "notes": null,
1062
1038
  "ventilation_standard": "ASHRAE 62.1-1999",
1063
- "ventilation_primary_space_type": null,
1064
- "ventilation_secondary_space_type": null,
1065
- "ventilation_per_area": 0.0,
1066
- "ventilation_per_person": 75.0,
1039
+ "ventilation_primary_space_type": "Public Spaces",
1040
+ "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
1041
+ "ventilation_per_area": 0.96,
1042
+ "ventilation_per_person": 0.0,
1067
1043
  "ventilation_air_changes": null,
1068
1044
  "minimum_total_air_changes": null,
1069
1045
  "infiltration_per_exterior_area": null,
@@ -1100,7 +1076,7 @@
1100
1076
  "lighting_standard": "DOE Ref 1980-2004",
1101
1077
  "lighting_primary_space_type": "Stair",
1102
1078
  "lighting_secondary_space_type": "General",
1103
- "lighting_per_area": 0.6,
1079
+ "lighting_per_area": 0.9,
1104
1080
  "rcr_threshold": null,
1105
1081
  "lighting_per_person": null,
1106
1082
  "additional_lighting_per_area": null,
@@ -1127,9 +1103,9 @@
1127
1103
  "occupancy_activity_schedule": null,
1128
1104
  "is_residential": null,
1129
1105
  "ventilation_standard": "ASHRAE 62.1-1999",
1130
- "ventilation_primary_space_type": null,
1131
- "ventilation_secondary_space_type": null,
1132
- "ventilation_per_area": 0.02,
1106
+ "ventilation_primary_space_type": "Public Spaces",
1107
+ "ventilation_secondary_space_type": "Corridors and utilities",
1108
+ "ventilation_per_area": 0.05,
1133
1109
  "ventilation_per_person": 0.0,
1134
1110
  "ventilation_air_changes": null,
1135
1111
  "minimum_total_air_changes": null,
@@ -1176,7 +1152,7 @@
1176
1152
  "lighting_standard": "DOE Ref 1980-2004",
1177
1153
  "lighting_primary_space_type": "Storage",
1178
1154
  "lighting_secondary_space_type": "General",
1179
- "lighting_per_area": 0.3,
1155
+ "lighting_per_area": 1.1,
1180
1156
  "rcr_threshold": null,
1181
1157
  "lighting_per_person": null,
1182
1158
  "additional_lighting_per_area": null,
@@ -1203,10 +1179,10 @@
1203
1179
  "occupancy_activity_schedule": "College ACTIVITY_SCH",
1204
1180
  "is_residential": null,
1205
1181
  "ventilation_standard": "ASHRAE 62.1-1999",
1206
- "ventilation_primary_space_type": null,
1207
- "ventilation_secondary_space_type": null,
1208
- "ventilation_per_area": 0.0,
1209
- "ventilation_per_person": 5.0,
1182
+ "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
1183
+ "ventilation_secondary_space_type": "Storage rooms",
1184
+ "ventilation_per_area": 0.15,
1185
+ "ventilation_per_person": 0.0,
1210
1186
  "ventilation_air_changes": null,
1211
1187
  "minimum_total_air_changes": null,
1212
1188
  "infiltration_per_exterior_area": null,
@@ -1249,15 +1225,51 @@
1249
1225
  "template": "DOE Ref 1980-2004",
1250
1226
  "building_type": "College",
1251
1227
  "space_type": "College - Utility",
1228
+ "lighting_standard": "DOE Ref 1980-2004",
1229
+ "lighting_primary_space_type": "Electrical/Mechanical",
1230
+ "lighting_secondary_space_type": "General",
1231
+ "lighting_per_area": 1.3,
1232
+ "rcr_threshold": null,
1233
+ "lighting_per_person": null,
1234
+ "additional_lighting_per_area": null,
1235
+ "lighting_fraction_to_return_air": null,
1236
+ "lighting_fraction_radiant": null,
1237
+ "lighting_fraction_visible": null,
1238
+ "lighting_fraction_replaceable": null,
1239
+ "lpd_fraction_linear_fluorescent": null,
1240
+ "lpd_fraction_compact_fluorescent": null,
1241
+ "lpd_fraction_high_bay": null,
1242
+ "lpd_fraction_specialty_lighting": null,
1243
+ "lpd_fraction_exit_lighting": null,
1244
+ "lighting_schedule": "College BLDG_LIGHT_SCH",
1245
+ "compact_fluorescent_lighting_schedule": null,
1246
+ "high_bay_lighting_schedule": null,
1247
+ "specialty_lighting_schedule": null,
1248
+ "exit_lighting_schedule": null,
1249
+ "target_illuminance_setpoint": null,
1250
+ "psa_nongeometry_fraction": null,
1251
+ "ssa_nongeometry_fraction": null,
1252
+ "notes": null,
1253
+ "gas_equipment_per_area": null,
1254
+ "gas_equipment_fraction_latent": null,
1255
+ "gas_equipment_fraction_radiant": null,
1256
+ "gas_equipment_fraction_lost": null,
1257
+ "gas_equipment_schedule": null,
1258
+ "electric_equipment_per_area": 0.37,
1259
+ "electric_equipment_fraction_latent": 0.0,
1260
+ "electric_equipment_fraction_radiant": 0.5,
1261
+ "electric_equipment_fraction_lost": 0.0,
1262
+ "electric_equipment_schedule": "College BLDG_EQUIP_SCH_Base",
1263
+ "additional_electric_equipment_schedule": null,
1264
+ "additional_gas_equipment_schedule": null,
1252
1265
  "occupancy_per_area": null,
1253
1266
  "occupancy_schedule": null,
1254
1267
  "occupancy_activity_schedule": null,
1255
1268
  "is_residential": null,
1256
- "notes": null,
1257
1269
  "ventilation_standard": "ASHRAE 62.1-1999",
1258
- "ventilation_primary_space_type": null,
1259
- "ventilation_secondary_space_type": null,
1260
- "ventilation_per_area": 0.02,
1270
+ "ventilation_primary_space_type": "Public Spaces",
1271
+ "ventilation_secondary_space_type": "Corridors and utilities",
1272
+ "ventilation_per_area": 0.05,
1261
1273
  "ventilation_per_person": 0.0,
1262
1274
  "ventilation_air_changes": null,
1263
1275
  "minimum_total_air_changes": null,