openstudio-standards 0.2.14 → 0.2.15.pre.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.json +0 -19
- data/data/geometry/ASHRAEMidriseApartment.json +47 -47
- data/data/geometry/ASHRAESecondarySchool.osm +2 -2
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/export_OpenStudio_libraries.rb +1 -1
- data/data/standards/manage_OpenStudio_Standards.rb +43 -87
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
- data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
- data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
- data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
- data/lib/openstudio-standards/btap/btap_result.rb +12 -10
- data/lib/openstudio-standards/btap/envelope.rb +2 -2
- data/lib/openstudio-standards/btap/geometry.rb +96 -49
- data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
- data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
- data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
- data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
- data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
- data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
- data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
- data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
- data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
- data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
- data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
- data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
- data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
- data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
- data/lib/openstudio-standards/standards/standard.rb +2 -1
- data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
- data/lib/openstudio-standards/utilities/logging.rb +6 -0
- data/lib/openstudio-standards/utilities/simulation.rb +30 -14
- data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
- data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
- data/lib/openstudio-standards/version.rb +2 -2
- data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
- data/lib/openstudio-standards.rb +9 -0
- metadata +106 -205
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
- data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
|
@@ -2,7 +2,7 @@ class Standard
|
|
|
2
2
|
# @!group hvac_systems
|
|
3
3
|
|
|
4
4
|
# Returns standard design sizing temperatures
|
|
5
|
-
|
|
5
|
+
#
|
|
6
6
|
# @return [Hash] Hash of design sizing temperature lookups
|
|
7
7
|
def standard_design_sizing_temperatures
|
|
8
8
|
dsgn_temps = {}
|
|
@@ -21,9 +21,9 @@ class Standard
|
|
|
21
21
|
return dsgn_temps
|
|
22
22
|
end
|
|
23
23
|
|
|
24
|
-
# Creates a hot water loop with a boiler, district heating, or a
|
|
25
|
-
# water-to-water heat pump and adds it to the model.
|
|
24
|
+
# Creates a hot water loop with a boiler, district heating, or a water-to-water heat pump and adds it to the model.
|
|
26
25
|
#
|
|
26
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
27
27
|
# @param boiler_fuel_type [String] valid choices are Electricity, NaturalGas, PropaneGas, FuelOilNo1, FuelOilNo2, DistrictHeating, HeatPump
|
|
28
28
|
# @param ambient_loop [OpenStudio::Model::PlantLoop] The condenser loop for the heat pump. Only used when boiler_fuel_type is HeatPump.
|
|
29
29
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
@@ -152,7 +152,7 @@ class Standard
|
|
|
152
152
|
max_plr: boiler_max_plr,
|
|
153
153
|
sizing_factor: boiler_sizing_factor)
|
|
154
154
|
|
|
155
|
-
#
|
|
155
|
+
# @todo Yixing. Adding temperature setpoint controller at boiler outlet causes simulation errors
|
|
156
156
|
# boiler_stpt_manager = OpenStudio::Model::SetpointManagerScheduled.new(self, hw_temp_sch)
|
|
157
157
|
# boiler_stpt_manager.setName("Boiler outlet setpoint manager")
|
|
158
158
|
# boiler_stpt_manager.addToNode(boiler.outletModelObject.get.to_Node.get)
|
|
@@ -186,6 +186,7 @@ class Standard
|
|
|
186
186
|
|
|
187
187
|
# Creates a chilled water loop and adds it to the model.
|
|
188
188
|
#
|
|
189
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
189
190
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
190
191
|
# @param cooling_fuel [String] cooling fuel. Valid choices are: Electricity, DistrictCooling
|
|
191
192
|
# @param dsgn_sup_wtr_temp [Double] design supply water temperature in degrees Fahrenheit, default 44F
|
|
@@ -249,8 +250,8 @@ class Standard
|
|
|
249
250
|
chw_stpt_manager = OpenStudio::Model::SetpointManagerScheduled.new(model, chw_temp_sch)
|
|
250
251
|
chw_stpt_manager.setName("#{chilled_water_loop.name} Setpoint Manager")
|
|
251
252
|
chw_stpt_manager.addToNode(chilled_water_loop.supplyOutletNode)
|
|
252
|
-
#
|
|
253
|
-
#
|
|
253
|
+
# @todo Yixing check the CHW Setpoint from standards
|
|
254
|
+
# @todo Should be a OutdoorAirReset, see the changes I've made in Standards.PlantLoop.apply_prm_baseline_temperatures
|
|
254
255
|
|
|
255
256
|
# create chilled water pumps
|
|
256
257
|
if chw_pumping_type == 'const_pri'
|
|
@@ -379,6 +380,7 @@ class Standard
|
|
|
379
380
|
|
|
380
381
|
# Creates a condenser water loop and adds it to the model.
|
|
381
382
|
#
|
|
383
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
382
384
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
383
385
|
# @param cooling_tower_type [String] valid choices are Open Cooling Tower, Closed Cooling Tower
|
|
384
386
|
# @param cooling_tower_fan_type [String] valid choices are Centrifugal, "Propeller or Axial"
|
|
@@ -501,7 +503,7 @@ class Standard
|
|
|
501
503
|
end
|
|
502
504
|
when 'TwoSpeed Fan'
|
|
503
505
|
cooling_tower = OpenStudio::Model::CoolingTowerTwoSpeed.new(model)
|
|
504
|
-
#
|
|
506
|
+
# @todo expose newer cooling tower sizing fields in API
|
|
505
507
|
# cooling_tower.setLowFanSpeedAirFlowRateSizingFactor(0.5)
|
|
506
508
|
# cooling_tower.setLowFanSpeedFanPowerSizingFactor(0.3)
|
|
507
509
|
# cooling_tower.setLowFanSpeedUFactorTimesAreaSizingFactor
|
|
@@ -557,7 +559,10 @@ class Standard
|
|
|
557
559
|
if EmbeddedScripting.hasFile(ddy_file)
|
|
558
560
|
ddy_string = EmbeddedScripting.getFileAsString(ddy_file)
|
|
559
561
|
temp_ddy_path = "#{Dir.pwd}/in.ddy"
|
|
560
|
-
File.open(temp_ddy_path, 'wb')
|
|
562
|
+
File.open(temp_ddy_path, 'wb') do |f|
|
|
563
|
+
f << ddy_string
|
|
564
|
+
f.flush
|
|
565
|
+
end
|
|
561
566
|
ddy_model = OpenStudio::EnergyPlus.loadAndTranslateIdf(temp_ddy_path).get
|
|
562
567
|
File.delete(temp_ddy_path) if File.exist?(temp_ddy_path)
|
|
563
568
|
else
|
|
@@ -629,6 +634,7 @@ class Standard
|
|
|
629
634
|
|
|
630
635
|
# Creates a heat pump loop which has a boiler and fluid cooler for supplemental heating/cooling and adds it to the model.
|
|
631
636
|
#
|
|
637
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
632
638
|
# @param heating_fuel [String]
|
|
633
639
|
# @param cooling_fuel [String] cooling fuel. Valid options are: Electricity, DistrictCooling
|
|
634
640
|
# @param cooling_type [String] cooling type if not DistrictCooling.
|
|
@@ -642,7 +648,7 @@ class Standard
|
|
|
642
648
|
# @param dsgn_sup_wtr_temp [Double] design supply water temperature in degrees Fahrenheit, default 102.2F
|
|
643
649
|
# @param dsgn_sup_wtr_temp_delt [Double] design supply-return water temperature difference in degrees Rankine, default 19.8R
|
|
644
650
|
# @return [OpenStudio::Model::PlantLoop] the resulting plant loop
|
|
645
|
-
#
|
|
651
|
+
# @todo replace cooling tower with fluid cooler after fixing sizing inputs
|
|
646
652
|
def model_add_hp_loop(model,
|
|
647
653
|
heating_fuel: 'NaturalGas',
|
|
648
654
|
cooling_fuel: 'Electricity',
|
|
@@ -840,9 +846,10 @@ class Standard
|
|
|
840
846
|
|
|
841
847
|
# Creates loop that roughly mimics a properly sized ground heat exchanger for supplemental heating/cooling and adds it to the model.
|
|
842
848
|
#
|
|
849
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
843
850
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
844
851
|
# @return [OpenStudio::Model::PlantLoop] the resulting plant loop
|
|
845
|
-
#
|
|
852
|
+
# @todo replace condenser loop w/ ground HX model that does not involve district objects
|
|
846
853
|
def model_add_ground_hx_loop(model,
|
|
847
854
|
system_name: 'Ground HX Loop')
|
|
848
855
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.Model.Model', 'Adding ground source loop.')
|
|
@@ -935,10 +942,11 @@ class Standard
|
|
|
935
942
|
|
|
936
943
|
# Adds an ambient condenser water loop that will be used in a district to connect buildings as a shared sink/source for heat pumps.
|
|
937
944
|
#
|
|
945
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
938
946
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
939
947
|
# @return [OpenStudio::Model::PlantLoop] the ambient loop
|
|
940
|
-
#
|
|
941
|
-
#
|
|
948
|
+
# @todo add inputs for design temperatures like heat pump loop object
|
|
949
|
+
# @todo handle ground and heat pump with this; make heating/cooling source options (boiler, fluid cooler, district)
|
|
942
950
|
def model_add_district_ambient_loop(model,
|
|
943
951
|
system_name: 'Ambient Loop')
|
|
944
952
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.Model.Model', 'Adding district ambient loop.')
|
|
@@ -1027,6 +1035,7 @@ class Standard
|
|
|
1027
1035
|
# Creates a DOAS system with cold supply and terminal units for each zone.
|
|
1028
1036
|
# This is the default DOAS system for DOE prototype buildings. Use model_add_doas for other DOAS systems.
|
|
1029
1037
|
#
|
|
1038
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
1030
1039
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
1031
1040
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
1032
1041
|
# @param hot_water_loop [OpenStudio::Model::PlantLoop] hot water loop to connect to heating and zone fan coils
|
|
@@ -1209,7 +1218,7 @@ class Standard
|
|
|
1209
1218
|
erv = OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent.new(model)
|
|
1210
1219
|
erv.addToNode(oa_system.outboardOANode.get)
|
|
1211
1220
|
erv.setHeatExchangerType('Rotary')
|
|
1212
|
-
#
|
|
1221
|
+
# @todo come up with scheme for estimating power of ERV motor wheel which might require knowing airflow.
|
|
1213
1222
|
# erv.setNominalElectricPower(value_new)
|
|
1214
1223
|
erv.setEconomizerLockout(true)
|
|
1215
1224
|
erv.setSupplyAirOutletTemperatureControl(false)
|
|
@@ -1254,6 +1263,7 @@ class Standard
|
|
|
1254
1263
|
|
|
1255
1264
|
# Creates a DOAS system with terminal units for each zone.
|
|
1256
1265
|
#
|
|
1266
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
1257
1267
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
1258
1268
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
1259
1269
|
# @param doas_type [String] DOASCV or DOASVAV, determines whether the DOAS is operated at scheduled,
|
|
@@ -1555,6 +1565,7 @@ class Standard
|
|
|
1555
1565
|
|
|
1556
1566
|
# Creates a VAV system and adds it to the model.
|
|
1557
1567
|
#
|
|
1568
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
1558
1569
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
1559
1570
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
1560
1571
|
# @param return_plenum [OpenStudio::Model::ThermalZone] the zone to attach as the supply plenum, or nil, in which case no return plenum will be used
|
|
@@ -1795,6 +1806,7 @@ class Standard
|
|
|
1795
1806
|
|
|
1796
1807
|
# Creates a VAV system with parallel fan powered boxes and adds it to the model.
|
|
1797
1808
|
#
|
|
1809
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
1798
1810
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
1799
1811
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
1800
1812
|
# @param chilled_water_loop [OpenStudio::Model::PlantLoop] chilled water loop to connect to the cooling coil
|
|
@@ -1926,6 +1938,7 @@ class Standard
|
|
|
1926
1938
|
|
|
1927
1939
|
# Creates a packaged VAV system and adds it to the model.
|
|
1928
1940
|
#
|
|
1941
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
1929
1942
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
1930
1943
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
1931
1944
|
# @param return_plenum [OpenStudio::Model::ThermalZone] the zone to attach as the supply plenum, or nil, in which case no return plenum will be used
|
|
@@ -2113,6 +2126,7 @@ class Standard
|
|
|
2113
2126
|
|
|
2114
2127
|
# Creates a packaged VAV system with parallel fan powered boxes and adds it to the model.
|
|
2115
2128
|
#
|
|
2129
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
2116
2130
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
2117
2131
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
2118
2132
|
# @param chilled_water_loop [OpenStudio::Model::PlantLoop] chilled water loop to connect cooling coils to. If nil, will be DX cooling
|
|
@@ -2251,6 +2265,7 @@ class Standard
|
|
|
2251
2265
|
|
|
2252
2266
|
# Creates a CAV system and adds it to the model.
|
|
2253
2267
|
#
|
|
2268
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
2254
2269
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
2255
2270
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
2256
2271
|
# @param hot_water_loop [OpenStudio::Model::PlantLoop] hot water loop to connect to heating and reheat coils.
|
|
@@ -2413,6 +2428,7 @@ class Standard
|
|
|
2413
2428
|
|
|
2414
2429
|
# Creates a PSZ-AC system for each zone and adds it to the model.
|
|
2415
2430
|
#
|
|
2431
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
2416
2432
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
2417
2433
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
2418
2434
|
# @param cooling_type [String] valid choices are Water, Two Speed DX AC, Single Speed DX AC, Single Speed Heat Pump, Water To Air Heat Pump
|
|
@@ -2655,7 +2671,7 @@ class Standard
|
|
|
2655
2671
|
oa_system.setName("#{air_loop.name} OA System")
|
|
2656
2672
|
oa_system.addToNode(air_loop.supplyInletNode)
|
|
2657
2673
|
|
|
2658
|
-
#
|
|
2674
|
+
# @todo enable economizer maximum fraction outdoor air schedule input
|
|
2659
2675
|
# econ_eff_sch = model_add_schedule(model, 'RetailStandalone PSZ_Econ_MaxOAFrac_Sch')
|
|
2660
2676
|
|
|
2661
2677
|
# set air loop availability controls and night cycle manager, after oa system added
|
|
@@ -2682,6 +2698,7 @@ class Standard
|
|
|
2682
2698
|
|
|
2683
2699
|
# Creates a packaged single zone VAV system for each zone and adds it to the model.
|
|
2684
2700
|
#
|
|
2701
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
2685
2702
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
2686
2703
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
2687
2704
|
# @param heating_type [String] valid choices are NaturalGas, Electricity, Water, nil (no heat)
|
|
@@ -2797,7 +2814,7 @@ class Standard
|
|
|
2797
2814
|
clg_coil.addSpeed(clg_spd_1)
|
|
2798
2815
|
clg_coil.setNominalSpeedLevel(1)
|
|
2799
2816
|
|
|
2800
|
-
#
|
|
2817
|
+
# @todo enable economizer maximum fraction outdoor air schedule input
|
|
2801
2818
|
# econ_eff_sch = model_add_schedule(model, 'RetailStandalone PSZ_Econ_MaxOAFrac_Sch')
|
|
2802
2819
|
|
|
2803
2820
|
# wrap coils in a unitary system
|
|
@@ -2807,7 +2824,7 @@ class Standard
|
|
|
2807
2824
|
unitary_system.setCoolingCoil(clg_coil)
|
|
2808
2825
|
unitary_system.setSupplementalHeatingCoil(supplemental_htg_coil)
|
|
2809
2826
|
unitary_system.setName("#{zone.name} Unitary PSZ-VAV")
|
|
2810
|
-
unitary_system.setString(2, 'SingleZoneVAV') #
|
|
2827
|
+
unitary_system.setString(2, 'SingleZoneVAV') # @todo add setControlType() method
|
|
2811
2828
|
unitary_system.setControllingZoneorThermostatLocation(zone)
|
|
2812
2829
|
unitary_system.setMaximumSupplyAirTemperature(dsgn_temps['zn_htg_dsgn_sup_air_temp_c'])
|
|
2813
2830
|
unitary_system.setFanPlacement('BlowThrough')
|
|
@@ -2844,6 +2861,7 @@ class Standard
|
|
|
2844
2861
|
|
|
2845
2862
|
# Adds a data center load to a given space.
|
|
2846
2863
|
#
|
|
2864
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
2847
2865
|
# @param space [OpenStudio::Model::Space] which space to assign the data center loads to
|
|
2848
2866
|
# @param dc_watts_per_area [Double] data center load, in W/m^2
|
|
2849
2867
|
# @return [Bool] returns true if successful, false if not
|
|
@@ -2863,6 +2881,7 @@ class Standard
|
|
|
2863
2881
|
|
|
2864
2882
|
# Creates a data center PSZ-AC system for each zone.
|
|
2865
2883
|
#
|
|
2884
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
2866
2885
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
2867
2886
|
# @param hot_water_loop [OpenStudio::Model::PlantLoop] hot water loop to connect to the heating coil
|
|
2868
2887
|
# @param heat_pump_loop [OpenStudio::Model::PlantLoop] heat pump water loop to connect to heat pump
|
|
@@ -3023,6 +3042,7 @@ class Standard
|
|
|
3023
3042
|
|
|
3024
3043
|
# Creates a CRAC system for data center and adds it to the model.
|
|
3025
3044
|
#
|
|
3045
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3026
3046
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
3027
3047
|
# @param thermal_zones [String] zones to connect to this system
|
|
3028
3048
|
# @param hvac_op_sch [String] name of the HVAC operation schedule
|
|
@@ -3235,6 +3255,7 @@ class Standard
|
|
|
3235
3255
|
|
|
3236
3256
|
# Creates a CRAH system for larger size data center and adds it to the model.
|
|
3237
3257
|
#
|
|
3258
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3238
3259
|
# @param chilled_water_loop [string]
|
|
3239
3260
|
# @param system_name [String] the name of the system, or nil in which case it will be defaulted
|
|
3240
3261
|
# @param thermal_zones [String] zones to connect to this system
|
|
@@ -3391,6 +3412,7 @@ class Standard
|
|
|
3391
3412
|
|
|
3392
3413
|
# Creates a split DX AC system for each zone and adds it to the model.
|
|
3393
3414
|
#
|
|
3415
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3394
3416
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
3395
3417
|
# @param cooling_type [String] valid choices are Two Speed DX AC, Single Speed DX AC, Single Speed Heat Pump
|
|
3396
3418
|
# @param heating_type [String] valid choices are Gas, Single Speed Heat Pump
|
|
@@ -3550,6 +3572,7 @@ class Standard
|
|
|
3550
3572
|
|
|
3551
3573
|
# Creates a minisplit heatpump system for each zone and adds it to the model.
|
|
3552
3574
|
#
|
|
3575
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3553
3576
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
3554
3577
|
# @param cooling_type [String] valid choices are Two Speed DX AC, Single Speed DX AC, Single Speed Heat Pump
|
|
3555
3578
|
# @param heating_type [String] valid choices are Single Speed DX
|
|
@@ -3664,6 +3687,7 @@ class Standard
|
|
|
3664
3687
|
|
|
3665
3688
|
# Creates a PTAC system for each zone and adds it to the model.
|
|
3666
3689
|
#
|
|
3690
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3667
3691
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
3668
3692
|
# @param cooling_type [String] valid choices are Two Speed DX AC, Single Speed DX AC
|
|
3669
3693
|
# @param heating_type [String] valid choices are NaturalGas, Electricity, Water, nil (no heat)
|
|
@@ -3785,6 +3809,7 @@ class Standard
|
|
|
3785
3809
|
|
|
3786
3810
|
# Creates a PTHP system for each zone and adds it to the model.
|
|
3787
3811
|
#
|
|
3812
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3788
3813
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
3789
3814
|
# @param fan_type [String] valid choices are ConstantVolume, Cycling
|
|
3790
3815
|
# @param ventilation [Bool] If true, ventilation will be supplied through the unit. If false,
|
|
@@ -3870,6 +3895,7 @@ class Standard
|
|
|
3870
3895
|
|
|
3871
3896
|
# Creates a unit heater for each zone and adds it to the model.
|
|
3872
3897
|
#
|
|
3898
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3873
3899
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
3874
3900
|
# @param hvac_op_sch [String] name of the HVAC operation schedule or nil in which case will be defaulted to always on
|
|
3875
3901
|
# @param fan_control_type [String] valid choices are OnOff, ConstantVolume, VariableVolume
|
|
@@ -3986,6 +4012,7 @@ class Standard
|
|
|
3986
4012
|
|
|
3987
4013
|
# Creates a high temp radiant heater for each zone and adds it to the model.
|
|
3988
4014
|
#
|
|
4015
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
3989
4016
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
3990
4017
|
# @param heating_type [String] valid choices are Gas, Electric
|
|
3991
4018
|
# @param combustion_efficiency [Double] combustion efficiency as decimal
|
|
@@ -4043,6 +4070,7 @@ class Standard
|
|
|
4043
4070
|
|
|
4044
4071
|
# Creates an evaporative cooler for each zone and adds it to the model.
|
|
4045
4072
|
#
|
|
4073
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4046
4074
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to connect to this system
|
|
4047
4075
|
# @return [Array<OpenStudio::Model::AirLoopHVAC>] the resulting evaporative coolers
|
|
4048
4076
|
def model_add_evap_cooler(model,
|
|
@@ -4127,7 +4155,7 @@ class Standard
|
|
|
4127
4155
|
programs << avail_program
|
|
4128
4156
|
|
|
4129
4157
|
# Direct Evap Cooler
|
|
4130
|
-
#
|
|
4158
|
+
# @todo better assumptions for evap cooler performance and fan pressure rise
|
|
4131
4159
|
evap = OpenStudio::Model::EvaporativeCoolerDirectResearchSpecial.new(model, model.alwaysOnDiscreteSchedule)
|
|
4132
4160
|
evap.setName("#{zone.name} Evap Media")
|
|
4133
4161
|
evap.autosizePrimaryAirDesignFlowRate
|
|
@@ -4198,6 +4226,7 @@ class Standard
|
|
|
4198
4226
|
|
|
4199
4227
|
# Adds hydronic or electric baseboard heating to each zone.
|
|
4200
4228
|
#
|
|
4229
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4201
4230
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add baseboards to.
|
|
4202
4231
|
# @param hot_water_loop [OpenStudio::Model::PlantLoop] The hot water loop that serves the baseboards. If nil, baseboards are electric.
|
|
4203
4232
|
# @return [Array<OpenStudio::Model::ZoneHVACBaseboardConvectiveElectric, OpenStudio::Model::ZoneHVACBaseboardConvectiveWater>]
|
|
@@ -4232,6 +4261,7 @@ class Standard
|
|
|
4232
4261
|
|
|
4233
4262
|
# Adds Variable Refrigerant Flow system and terminal units for each zone
|
|
4234
4263
|
#
|
|
4264
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4235
4265
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add fan coil units
|
|
4236
4266
|
# @param ventilation [Bool] If true, ventilation will be supplied through the unit. If false,
|
|
4237
4267
|
# no ventilation will be supplied through the unit, with the expectation that it will be provided by a DOAS or separate system.
|
|
@@ -4288,6 +4318,7 @@ class Standard
|
|
|
4288
4318
|
|
|
4289
4319
|
# Adds four pipe fan coil units to each zone.
|
|
4290
4320
|
#
|
|
4321
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4291
4322
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add fan coil units
|
|
4292
4323
|
# @param chilled_water_loop [OpenStudio::Model::PlantLoop] the chilled water loop that serves the fan coils.
|
|
4293
4324
|
# @param hot_water_loop [OpenStudio::Model::PlantLoop] the hot water loop that serves the fan coils.
|
|
@@ -4372,6 +4403,7 @@ class Standard
|
|
|
4372
4403
|
|
|
4373
4404
|
# Adds low temperature radiant loop systems to each zone.
|
|
4374
4405
|
#
|
|
4406
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4375
4407
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add radiant loops
|
|
4376
4408
|
# @param hot_water_loop [OpenStudio::Model::PlantLoop] the hot water loop that serves the radiant loop.
|
|
4377
4409
|
# @param chilled_water_loop [OpenStudio::Model::PlantLoop] the chilled water loop that serves the radiant loop.
|
|
@@ -4394,7 +4426,7 @@ class Standard
|
|
|
4394
4426
|
# @param radiant_lockout_end_time [double] decimal hour of when radiant lockout ends
|
|
4395
4427
|
# Only used if radiant_lockout is true
|
|
4396
4428
|
# @return [Array<OpenStudio::Model::ZoneHVACLowTemperatureRadiantVariableFlow>] array of radiant objects.
|
|
4397
|
-
#
|
|
4429
|
+
# @todo Once the OpenStudio API supports it, make chilled water loops optional for heating only systems
|
|
4398
4430
|
def model_add_low_temp_radiant(model,
|
|
4399
4431
|
thermal_zones,
|
|
4400
4432
|
hot_water_loop,
|
|
@@ -4693,7 +4725,7 @@ class Standard
|
|
|
4693
4725
|
|
|
4694
4726
|
# radiant loop layout details
|
|
4695
4727
|
radiant_loop.setHydronicTubingInsideDiameter(0.015875) # 5/8 in. ID, 3/4 in. OD
|
|
4696
|
-
# @
|
|
4728
|
+
# @todo include a method to determine tubing length in the zone
|
|
4697
4729
|
# loop_length = 7*zone.floorArea
|
|
4698
4730
|
# radiant_loop.setHydronicTubingLength()
|
|
4699
4731
|
radiant_loop.setNumberofCircuits('CalculateFromCircuitLength')
|
|
@@ -4725,6 +4757,7 @@ class Standard
|
|
|
4725
4757
|
# Adds a window air conditioner to each zone.
|
|
4726
4758
|
# Code adapted from: https://github.com/NREL/OpenStudio-BEopt/blob/master/measures/ResidentialHVACRoomAirConditioner/measure.rb
|
|
4727
4759
|
#
|
|
4760
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4728
4761
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add fan coil units to.
|
|
4729
4762
|
# @return [Array<OpenStudio::Model::ZoneHVACPackagedTerminalAirConditioner>] and array of PTACs used as window AC units
|
|
4730
4763
|
def model_add_window_ac(model,
|
|
@@ -4779,6 +4812,7 @@ class Standard
|
|
|
4779
4812
|
# Code adapted from:
|
|
4780
4813
|
# https://github.com/NREL/OpenStudio-BEopt/blob/master/measures/ResidentialHVACFurnaceFuel/measure.rb
|
|
4781
4814
|
#
|
|
4815
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4782
4816
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add fan coil units to.
|
|
4783
4817
|
# @param heating [Bool] if true, the unit will include a NaturalGas heating coil
|
|
4784
4818
|
# @param cooling [Bool] if true, the unit will include a DX cooling coil
|
|
@@ -4909,6 +4943,7 @@ class Standard
|
|
|
4909
4943
|
# Code adapted from:
|
|
4910
4944
|
# https://github.com/NREL/OpenStudio-BEopt/blob/master/measures/ResidentialHVACAirSourceHeatPumpSingleSpeed/measure.rb
|
|
4911
4945
|
#
|
|
4946
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
4912
4947
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add fan coil units to.
|
|
4913
4948
|
# @param heating [Bool] if true, the unit will include a NaturalGas heating coil
|
|
4914
4949
|
# @param cooling [Bool] if true, the unit will include a DX cooling coil
|
|
@@ -5044,6 +5079,7 @@ class Standard
|
|
|
5044
5079
|
|
|
5045
5080
|
# Adds zone level water-to-air heat pumps for each zone.
|
|
5046
5081
|
#
|
|
5082
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5047
5083
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones served by heat pumps
|
|
5048
5084
|
# @param condenser_loop [OpenStudio::Model::PlantLoop] the condenser loop for the heat pumps #
|
|
5049
5085
|
# @param ventilation [Bool] if true, ventilation will be supplied through the unit.
|
|
@@ -5095,9 +5131,10 @@ class Standard
|
|
|
5095
5131
|
|
|
5096
5132
|
# Adds zone level ERVs for each zone.
|
|
5097
5133
|
#
|
|
5134
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5098
5135
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to add heat pumps to.
|
|
5099
5136
|
# @return [Array<OpenStudio::Model::ZoneHVACEnergyRecoveryVentilator>] an array of zone ERVs
|
|
5100
|
-
#
|
|
5137
|
+
# @todo review the static pressure rise for the ERV
|
|
5101
5138
|
def model_add_zone_erv(model,
|
|
5102
5139
|
thermal_zones)
|
|
5103
5140
|
ervs = []
|
|
@@ -5192,6 +5229,7 @@ class Standard
|
|
|
5192
5229
|
|
|
5193
5230
|
# Adds ideal air loads systems for each zone.
|
|
5194
5231
|
#
|
|
5232
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5195
5233
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] array of zones to enable ideal air loads
|
|
5196
5234
|
# @param hvac_op_sch [String] name of the HVAC operation schedule, default is always on
|
|
5197
5235
|
# @param heat_avail_sch [String] name of the heating availability schedule, default is always on
|
|
@@ -5269,7 +5307,7 @@ class Standard
|
|
|
5269
5307
|
ideal_loads.setHumidificationControlType(humid_ctrl_type)
|
|
5270
5308
|
if include_outdoor_air
|
|
5271
5309
|
# get the design specification outdoor air of the largest space in the zone
|
|
5272
|
-
#
|
|
5310
|
+
# @todo create a new design specification outdoor air object that sums ventilation rates and schedules if multiple design specification outdoor air objects
|
|
5273
5311
|
space_areas = zone.spaces.map(&:floorArea)
|
|
5274
5312
|
largest_space = zone.spaces.select { |s| s.floorArea == space_areas.max }
|
|
5275
5313
|
largest_space = largest_space[0]
|
|
@@ -5353,13 +5391,14 @@ class Standard
|
|
|
5353
5391
|
|
|
5354
5392
|
# Adds an exhaust fan to each zone.
|
|
5355
5393
|
#
|
|
5394
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5356
5395
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] an array of thermal zones
|
|
5357
5396
|
# @param flow_rate [Double] the exhaust fan flow rate in m^3/s
|
|
5358
5397
|
# @param availability_sch_name [String] the name of the fan availability schedule
|
|
5359
5398
|
# @param flow_fraction_schedule_name [String] the name of the flow fraction schedule
|
|
5360
5399
|
# @param balanced_exhaust_fraction_schedule_name [String] the name of the balanced exhaust fraction schedule
|
|
5361
5400
|
# @return [Array<OpenStudio::Model::FanZoneExhaust>] an array of exhaust fans created
|
|
5362
|
-
# @todo
|
|
5401
|
+
# @todo use the create_fan_zone_exhaust method, default to 1.25 inH2O pressure rise and fan efficiency of 0.6
|
|
5363
5402
|
def model_add_exhaust_fan(model,
|
|
5364
5403
|
thermal_zones,
|
|
5365
5404
|
flow_rate: nil,
|
|
@@ -5410,6 +5449,7 @@ class Standard
|
|
|
5410
5449
|
|
|
5411
5450
|
# Adds a zone ventilation design flow rate to each zone.
|
|
5412
5451
|
#
|
|
5452
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5413
5453
|
# @param thermal_zones [Array<OpenStudio::Model::ThermalZone>] an array of thermal zones
|
|
5414
5454
|
# @param ventilation_type [String] the zone ventilation type either Exhaust, Natural, or Intake
|
|
5415
5455
|
# @param flow_rate [Double] the ventilation design flow rate in m^3/s
|
|
@@ -5488,6 +5528,7 @@ class Standard
|
|
|
5488
5528
|
|
|
5489
5529
|
# Get the existing chilled water loop in the model or add a new one if there isn't one already.
|
|
5490
5530
|
#
|
|
5531
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5491
5532
|
# @param cool_fuel [String] the cooling fuel. Valid choices are Electricity, DistrictCooling, and HeatPump.
|
|
5492
5533
|
# @param chilled_water_loop_cooling_type [String] Archetype for chilled water loops, AirCooled or WaterCooled
|
|
5493
5534
|
def model_get_or_add_chilled_water_loop(model, cool_fuel,
|
|
@@ -5537,6 +5578,8 @@ class Standard
|
|
|
5537
5578
|
end
|
|
5538
5579
|
|
|
5539
5580
|
# Determine which type of fan the cooling tower will have. Defaults to TwoSpeed Fan.
|
|
5581
|
+
#
|
|
5582
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5540
5583
|
# @return [String] the fan type: TwoSpeed Fan, Variable Speed Fan
|
|
5541
5584
|
def model_cw_loop_cooling_tower_fan_type(model)
|
|
5542
5585
|
fan_type = 'Variable Speed Fan'
|
|
@@ -5545,6 +5588,7 @@ class Standard
|
|
|
5545
5588
|
|
|
5546
5589
|
# Adds a waterside economizer to the chilled water and condenser loop
|
|
5547
5590
|
#
|
|
5591
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5548
5592
|
# @param integrated [Bool] when set to true, models an integrated waterside economizer
|
|
5549
5593
|
# Integrated: in series with chillers, can run simultaneously with chillers
|
|
5550
5594
|
# Non-Integrated: in parallel with chillers, chillers locked out during operation
|
|
@@ -5693,6 +5737,7 @@ class Standard
|
|
|
5693
5737
|
|
|
5694
5738
|
# Get the existing hot water loop in the model or add a new one if there isn't one already.
|
|
5695
5739
|
#
|
|
5740
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5696
5741
|
# @param heat_fuel [String] the heating fuel. Valid choices are NaturalGas, Electricity, DistrictHeating
|
|
5697
5742
|
# @param hot_water_loop_type [String] Archetype for hot water loops
|
|
5698
5743
|
# HighTemperature (180F supply) or LowTemperature (120F supply)
|
|
@@ -5735,6 +5780,9 @@ class Standard
|
|
|
5735
5780
|
end
|
|
5736
5781
|
|
|
5737
5782
|
# Get the existing ambient water loop in the model or add a new one if there isn't one already.
|
|
5783
|
+
#
|
|
5784
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5785
|
+
# @return [OpenStudio::Model::PlantLoop] the ambient water loop
|
|
5738
5786
|
def model_get_or_add_ambient_water_loop(model)
|
|
5739
5787
|
# retrieve the existing hot water loop or add a new one if necessary
|
|
5740
5788
|
ambient_water_loop = if model.getPlantLoopByName('Ambient Loop').is_initialized
|
|
@@ -5746,6 +5794,9 @@ class Standard
|
|
|
5746
5794
|
end
|
|
5747
5795
|
|
|
5748
5796
|
# Get the existing ground heat exchanger loop in the model or add a new one if there isn't one already.
|
|
5797
|
+
#
|
|
5798
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5799
|
+
# @return [OpenStudio::Model::PlantLoop] the ground hx loop
|
|
5749
5800
|
def model_get_or_add_ground_hx_loop(model)
|
|
5750
5801
|
# retrieve the existing ground HX loop or add a new one if necessary
|
|
5751
5802
|
ground_hx_loop = if model.getPlantLoopByName('Ground HX Loop').is_initialized
|
|
@@ -5758,6 +5809,7 @@ class Standard
|
|
|
5758
5809
|
|
|
5759
5810
|
# Get the existing heat pump loop in the model or add a new one if there isn't one already.
|
|
5760
5811
|
#
|
|
5812
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5761
5813
|
# @param heat_fuel [String] the heating fuel. Valid choices are NaturalGas, Electricity, DistrictHeating
|
|
5762
5814
|
# @param cool_fuel [String] the cooling fuel. Valid choices are Electricity and DistrictCooling.
|
|
5763
5815
|
# @param heat_pump_loop_cooling_type [String] the type of cooling equipment if not DistrictCooling.
|
|
@@ -5779,6 +5831,7 @@ class Standard
|
|
|
5779
5831
|
# Add the specified system type to the specified zones based on the specified template.
|
|
5780
5832
|
# For multi-zone system types, add one system per story.
|
|
5781
5833
|
#
|
|
5834
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
|
5782
5835
|
# @param system_type [String] The system type
|
|
5783
5836
|
# @param main_heat_fuel [String] Main heating fuel used for air loops and plant loops
|
|
5784
5837
|
# @param zone_heat_fuel [String] Zone heating fuel for zone hvac equipment and terminal units
|
|
@@ -6423,48 +6476,181 @@ class Standard
|
|
|
6423
6476
|
rename_plant_loop_nodes(model)
|
|
6424
6477
|
end
|
|
6425
6478
|
|
|
6426
|
-
#
|
|
6427
|
-
#
|
|
6428
|
-
|
|
6429
|
-
|
|
6430
|
-
|
|
6431
|
-
|
|
6432
|
-
|
|
6433
|
-
|
|
6434
|
-
|
|
6435
|
-
|
|
6436
|
-
|
|
6437
|
-
|
|
6438
|
-
|
|
6439
|
-
|
|
6440
|
-
|
|
6441
|
-
|
|
6442
|
-
|
|
6443
|
-
|
|
6444
|
-
|
|
6445
|
-
|
|
6446
|
-
|
|
6447
|
-
|
|
6448
|
-
|
|
6449
|
-
|
|
6450
|
-
|
|
6451
|
-
|
|
6452
|
-
|
|
6453
|
-
|
|
6454
|
-
|
|
6455
|
-
|
|
6456
|
-
|
|
6457
|
-
|
|
6458
|
-
|
|
6459
|
-
|
|
6460
|
-
|
|
6461
|
-
|
|
6462
|
-
|
|
6463
|
-
|
|
6464
|
-
|
|
6465
|
-
|
|
6466
|
-
|
|
6467
|
-
|
|
6468
|
-
|
|
6479
|
+
# Add a residential ERV: standalone ERV that operates to provide OA,
|
|
6480
|
+
# use in conjuction witha system that having mechanical cooling and
|
|
6481
|
+
# a heating coil
|
|
6482
|
+
#
|
|
6483
|
+
# @param model [OpenStudio::Model::Model] OpenStudio Model object
|
|
6484
|
+
# @param thermal_zone [OpenStudio::Model::ThermalZone] OpenStudio ThermalZone object
|
|
6485
|
+
# @param climate_zone [String] Climate zone
|
|
6486
|
+
# @param energy_recovery [Boolean] Indicates if the ERV is to recover energy, if false, only provides OA
|
|
6487
|
+
# @return [OpenStudio::Model::ZoneHVACEnergyRecoveryVentilator] Standalone ERV
|
|
6488
|
+
def model_add_residential_erv(model,
|
|
6489
|
+
thermal_zone,
|
|
6490
|
+
climate_zone,
|
|
6491
|
+
energy_recovery,
|
|
6492
|
+
min_oa_flow_m3_per_s_per_m2 = nil)
|
|
6493
|
+
|
|
6494
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.Model.Model', "Adding standalone ERV for #{thermal_zone.name}.")
|
|
6495
|
+
|
|
6496
|
+
# Exception 3 to 6.5.6.1.1
|
|
6497
|
+
case template
|
|
6498
|
+
when '90.1-2019'
|
|
6499
|
+
case climate_zone
|
|
6500
|
+
when 'ASHRAE 169-2006-0A',
|
|
6501
|
+
'ASHRAE 169-2006-0B',
|
|
6502
|
+
'ASHRAE 169-2006-1A',
|
|
6503
|
+
'ASHRAE 169-2006-1B',
|
|
6504
|
+
'ASHRAE 169-2006-2A',
|
|
6505
|
+
'ASHRAE 169-2006-2B',
|
|
6506
|
+
'ASHRAE 169-2006-3A',
|
|
6507
|
+
'ASHRAE 169-2006-3B',
|
|
6508
|
+
'ASHRAE 169-2006-3C',
|
|
6509
|
+
'ASHRAE 169-2006-4A',
|
|
6510
|
+
'ASHRAE 169-2006-4B',
|
|
6511
|
+
'ASHRAE 169-2006-4C',
|
|
6512
|
+
'ASHRAE 169-2006-5A',
|
|
6513
|
+
'ASHRAE 169-2006-5B',
|
|
6514
|
+
'ASHRAE 169-2006-5C',
|
|
6515
|
+
'ASHRAE 169-2013-0A',
|
|
6516
|
+
'ASHRAE 169-2013-0B',
|
|
6517
|
+
'ASHRAE 169-2013-1A',
|
|
6518
|
+
'ASHRAE 169-2013-1B',
|
|
6519
|
+
'ASHRAE 169-2013-2A',
|
|
6520
|
+
'ASHRAE 169-2013-2B',
|
|
6521
|
+
'ASHRAE 169-2013-3A',
|
|
6522
|
+
'ASHRAE 169-2013-3B',
|
|
6523
|
+
'ASHRAE 169-2013-3C',
|
|
6524
|
+
'ASHRAE 169-2013-4A',
|
|
6525
|
+
'ASHRAE 169-2013-4B',
|
|
6526
|
+
'ASHRAE 169-2013-4C',
|
|
6527
|
+
'ASHRAE 169-2013-5A',
|
|
6528
|
+
'ASHRAE 169-2013-5B',
|
|
6529
|
+
'ASHRAE 169-2013-5C'
|
|
6530
|
+
if thermal_zone_floor_area(thermal_zone) <= OpenStudio.convert(500, 'ft^2', 'm^2').get
|
|
6531
|
+
energy_recovery = false
|
|
6532
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.Model.Model', "Energy recovery will not be modeled for the ERV serving #{thermal_zone.name}.")
|
|
6533
|
+
end
|
|
6534
|
+
end
|
|
6535
|
+
end
|
|
6536
|
+
|
|
6537
|
+
# Determine ERR and design basis when energy recovery is required
|
|
6538
|
+
#
|
|
6539
|
+
# enthalpy_recovery_ratio = nil will trigger an ERV with no effectiveness that only provides OA
|
|
6540
|
+
enthalpy_recovery_ratio = nil
|
|
6541
|
+
if energy_recovery
|
|
6542
|
+
case template
|
|
6543
|
+
when '90.1-2019'
|
|
6544
|
+
search_criteria = {
|
|
6545
|
+
'template' => template,
|
|
6546
|
+
'climate_zone' => climate_zone,
|
|
6547
|
+
'under_8000_hours' => false,
|
|
6548
|
+
'nontransient_dwelling' => true
|
|
6549
|
+
}
|
|
6550
|
+
else
|
|
6551
|
+
search_criteria = {
|
|
6552
|
+
'template' => template,
|
|
6553
|
+
'climate_zone' => climate_zone,
|
|
6554
|
+
'under_8000_hours' => false
|
|
6555
|
+
}
|
|
6556
|
+
end
|
|
6557
|
+
|
|
6558
|
+
erv_enthalpy_recovery_ratio = model_find_object(standards_data['energy_recovery'], search_criteria)
|
|
6559
|
+
|
|
6560
|
+
# Extract ERR from data lookup
|
|
6561
|
+
if !erv_enthalpy_recovery_ratio.nil?
|
|
6562
|
+
if erv_enthalpy_recovery_ratio['enthalpy_recovery_ratio'].nil? & erv_enthalpy_recovery_ratio['enthalpy_recovery_ratio_design_conditions'].nil?
|
|
6563
|
+
# If not included in the data, an enthalpy
|
|
6564
|
+
# recovery ratio (ERR) of 50% is used
|
|
6565
|
+
enthalpy_recovery_ratio = 0.5
|
|
6566
|
+
case climate_zone
|
|
6567
|
+
when 'ASHRAE 169-2006-6B',
|
|
6568
|
+
'ASHRAE 169-2013-6B',
|
|
6569
|
+
'ASHRAE 169-2006-7A',
|
|
6570
|
+
'ASHRAE 169-2013-7A',
|
|
6571
|
+
'ASHRAE 169-2006-7B',
|
|
6572
|
+
'ASHRAE 169-2013-7B',
|
|
6573
|
+
'ASHRAE 169-2006-8A',
|
|
6574
|
+
'ASHRAE 169-2013-8A',
|
|
6575
|
+
'ASHRAE 169-2006-8B',
|
|
6576
|
+
'ASHRAE 169-2013-8B'
|
|
6577
|
+
design_conditions = 'heating'
|
|
6578
|
+
else
|
|
6579
|
+
design_conditions = 'cooling'
|
|
6580
|
+
end
|
|
6581
|
+
else
|
|
6582
|
+
design_conditions = erv_enthalpy_recovery_ratio['enthalpy_recovery_ratio_design_conditions'].downcase
|
|
6583
|
+
enthalpy_recovery_ratio = erv_enthalpy_recovery_ratio['enthalpy_recovery_ratio']
|
|
6584
|
+
end
|
|
6585
|
+
end
|
|
6586
|
+
end
|
|
6587
|
+
|
|
6588
|
+
# Create fans
|
|
6589
|
+
#
|
|
6590
|
+
# Fan power:
|
|
6591
|
+
# No energy recovery = 0.806 W/cfm
|
|
6592
|
+
# Energy recovery = 0.934 W/cfm
|
|
6593
|
+
supply_fan = create_fan_by_name(model,
|
|
6594
|
+
'ERV_Supply_Fan',
|
|
6595
|
+
fan_name: "#{thermal_zone.name} ERV Supply Fan")
|
|
6596
|
+
exhaust_fan = create_fan_by_name(model,
|
|
6597
|
+
'ERV_Supply_Fan',
|
|
6598
|
+
fan_name: "#{thermal_zone.name} ERV Exhaust Fan")
|
|
6599
|
+
supply_fan.setMotorEfficiency(0.48)
|
|
6600
|
+
exhaust_fan.setMotorEfficiency(0.48)
|
|
6601
|
+
supply_fan.setFanTotalEfficiency(0.303158)
|
|
6602
|
+
exhaust_fan.setFanTotalEfficiency(0.303158)
|
|
6603
|
+
if energy_recovery
|
|
6604
|
+
supply_fan.setPressureRise(270.64755)
|
|
6605
|
+
exhaust_fan.setPressureRise(270.64755)
|
|
6606
|
+
else
|
|
6607
|
+
supply_fan.setPressureRise(233.6875)
|
|
6608
|
+
exhaust_fan.setPressureRise(233.6875)
|
|
6609
|
+
end
|
|
6610
|
+
|
|
6611
|
+
# Create ERV Controller
|
|
6612
|
+
erv_controller = OpenStudio::Model::ZoneHVACEnergyRecoveryVentilatorController.new(model)
|
|
6613
|
+
erv_controller.setName("#{thermal_zone.name} ERV Controller")
|
|
6614
|
+
erv_controller.setControlHighIndoorHumidityBasedonOutdoorHumidityRatio(false)
|
|
6615
|
+
|
|
6616
|
+
# Create heat exchanger
|
|
6617
|
+
heat_exchanger = OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent.new(model)
|
|
6618
|
+
heat_exchanger.setName("#{thermal_zone.name} ERV HX")
|
|
6619
|
+
heat_exchanger.setSupplyAirOutletTemperatureControl(false)
|
|
6620
|
+
heat_exchanger.setHeatExchangerType('Rotary')
|
|
6621
|
+
heat_exchanger.setEconomizerLockout(false)
|
|
6622
|
+
heat_exchanger.setFrostControlType('ExhaustOnly')
|
|
6623
|
+
heat_exchanger.setThresholdTemperature(-23.3)
|
|
6624
|
+
heat_exchanger.setInitialDefrostTimeFraction(0.167)
|
|
6625
|
+
heat_exchanger.setRateofDefrostTimeFractionIncrease(1.44)
|
|
6626
|
+
heat_exchanger.setAvailabilitySchedule(model_add_schedule(model, 'Always On - No Design Day'))
|
|
6627
|
+
heat_exchanger_air_to_air_sensible_and_latent_apply_prototype_efficiency_enthalpy_recovery_ratio(heat_exchanger, enthalpy_recovery_ratio, design_conditions, climate_zone)
|
|
6628
|
+
|
|
6629
|
+
erv = OpenStudio::Model::ZoneHVACEnergyRecoveryVentilator.new(model, heat_exchanger, supply_fan, exhaust_fan)
|
|
6630
|
+
erv.setName("#{thermal_zone.name} ERV")
|
|
6631
|
+
|
|
6632
|
+
erv.setController(erv_controller)
|
|
6633
|
+
erv.addToThermalZone(thermal_zone)
|
|
6634
|
+
|
|
6635
|
+
# Set OA requirements; Assumes a default of 55 cfm
|
|
6636
|
+
if min_oa_flow_m3_per_s_per_m2.nil?
|
|
6637
|
+
erv.setSupplyAirFlowRate(OpenStudio.convert(55.0, 'cfm', 'm^3/s').get)
|
|
6638
|
+
erv.setExhaustAirFlowRate(OpenStudio.convert(55.0, 'cfm', 'm^3/s').get)
|
|
6639
|
+
else
|
|
6640
|
+
erv.setVentilationRateperUnitFloorArea(min_oa_flow_m3_per_s_per_m2)
|
|
6641
|
+
end
|
|
6642
|
+
erv.setVentilationRateperOccupant(0.0)
|
|
6643
|
+
|
|
6644
|
+
# Ensure the ERV takes priority, so ventilation load is included when treated by other zonal systems
|
|
6645
|
+
# From EnergyPlus I/O reference:
|
|
6646
|
+
# "For situations where one or more equipment types has limited capacity or limited control capability, order the
|
|
6647
|
+
# sequence so that the most controllable piece of equipment runs last. For example, with a dedicated outdoor air
|
|
6648
|
+
# system (DOAS), the air terminal for the DOAS should be assigned Heating Sequence = 1 and Cooling Sequence = 1.
|
|
6649
|
+
# Any other equipment should be assigned sequence 2 or higher so that it will see the net load after the DOAS air
|
|
6650
|
+
# is added to the zone."
|
|
6651
|
+
thermal_zone.setCoolingPriority(erv.to_ModelObject.get, 1)
|
|
6652
|
+
thermal_zone.setHeatingPriority(erv.to_ModelObject.get, 1)
|
|
6653
|
+
|
|
6654
|
+
return erv
|
|
6469
6655
|
end
|
|
6470
6656
|
end
|