- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.json +0 -19
- data/data/geometry/ASHRAEMidriseApartment.json +47 -47
- data/data/geometry/ASHRAESecondarySchool.osm +2 -2
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/export_OpenStudio_libraries.rb +1 -1
- data/data/standards/manage_OpenStudio_Standards.rb +43 -87
- data/data/standards/metadata_units_OpenStudio_Standards-ashrae_90_1.csv +9 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +142 -27
- data/data/standards/test_performance_expected_dd_results.csv +2016 -2016
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.ddy +2316 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.epw +8768 -0
- data/data/weather/CAN_NU_Iqaluit.AP.719090_CWEC2016.stat +697 -0
- data/lib/openstudio-standards/btap/WeatherData1.json +54 -0
- data/lib/openstudio-standards/btap/WeatherData1.xlsx +0 -0
- data/lib/openstudio-standards/btap/btap_result.rb +12 -10
- data/lib/openstudio-standards/btap/envelope.rb +2 -2
- data/lib/openstudio-standards/btap/geometry.rb +96 -49
- data/lib/openstudio-standards/{utilities → btap/utilities}/Add_template_field_to_json.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/convert_surfaces_to_adiabatic_necb_8426.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/generate_space_types.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/necb_to_epw_map.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/os_sim_extract.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/rename_surfaces.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/round_surf_coords.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/sched_create.rb +0 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/set_mult_to_adiabatic.rb +0 -0
- data/lib/openstudio-standards/btap/utilities/space_type.rb +78 -0
- data/lib/openstudio-standards/{utilities → btap/utilities}/weatherData1_xlsx_to_json.rb +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +1 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +20 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +6 -6
- data/lib/openstudio-standards/hvac_sizing/Siz.WaterHeaterMixed.rb +2 -2
- data/lib/openstudio-standards/hvac_sizing/Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +6 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.elevators.rb +6 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +10 -9
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +17 -16
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +9 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +23 -22
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +89 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +9 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +76 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +22 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +11 -11
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +5 -5
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +5 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +2 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +11 -7
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +10 -10
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +4 -2
- data/lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb +3 -6
- data/lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanOnOff.rb +5 -4
- data/lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanVariableVolume.rb +5 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +65 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +54 -23
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +135 -147
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +42 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +85 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +42 -30
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +39 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +60 -12
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +33 -265
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +41 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +69 -297
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +68 -25
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +88 -59
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +88 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +48 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +130 -145
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +29 -101
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +24 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +48 -589
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +38 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +38 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +40 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +85 -171
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +87 -44
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +46 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +105 -17
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +97 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +26 -167
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +3828 -1131
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +2 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +2 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +9 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +4 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +23 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +29 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +29 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +43 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +22 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +46 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.elevators.rb +27 -22
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +15 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +22 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +429 -59
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +11 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +1 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +8 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +37 -28
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +24 -6
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -65
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +46 -31
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +62 -10
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +76 -33
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +445 -275
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +26 -21
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +7 -9
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +8 -2
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +10 -6
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +5 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +45 -4
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +18 -8
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +8 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +86 -3
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +5 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +6 -2
- data/lib/openstudio-standards/standards/Standards.Construction.rb +66 -35
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +53 -35
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +22 -16
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +77 -19
- data/lib/openstudio-standards/standards/Standards.Model.rb +387 -245
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +13 -15
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -48
- data/lib/openstudio-standards/standards/Standards.Pump.rb +28 -20
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +3 -4
- data/lib/openstudio-standards/standards/Standards.ScheduleCompact.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -0
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +34 -24
- data/lib/openstudio-standards/standards/Standards.Space.rb +179 -116
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +23 -12
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +55 -25
- data/lib/openstudio-standards/standards/Standards.Surface.rb +57 -32
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +157 -107
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +9 -6
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +52 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +28 -18
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/comstock_ashrae_90_1_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +123 -123
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +395 -384
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirLoopHVAC.rb +20 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/comstock_ashrae_90_1_2007.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +122 -122
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +413 -401
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +42 -53
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/comstock_ashrae_90_1_2010.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +129 -129
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +210 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +460 -320
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +45 -51
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/comstock_ashrae_90_1_2013.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +420 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +12 -12
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +475 -335
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +40 -50
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +8 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +152 -128
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.energy_recovery.json +488 -84
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +342 -56
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +30 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +151 -127
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.boilers.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.energy_recovery.json +2307 -101
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.refrigeration_compressors.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +47 -47
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.unitary_acs.json +69 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +25 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +286 -224
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/comstock_doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.ext_ltg.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +126 -126
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.furnaces.json +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +405 -393
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +696 -2938
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +121 -121
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.furnaces.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.prototype_inputs.json +11 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.refrigeration_system.json +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +403 -391
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +15 -11
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +64 -42
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb +4 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.furnaces.json +15 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +61 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +3 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +5 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +4 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +6 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +3 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +20 -14
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +3 -0
- data/lib/openstudio-standards/standards/cbes/cbes.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_pre_1978/cbes_pre_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1978/cbes_t24_1978.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_1992/cbes_t24_1992.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2001/cbes_t24_2001.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.rb +4 -0
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +10 -5
- data/lib/openstudio-standards/standards/deer/deer.PlanarSurface.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/comstock_deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/comstock_deer_1985/data/comstock_deer_1985.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1985/deer_1985.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/comstock_deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/comstock_deer_1996/data/comstock_deer_1996.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_1996/deer_1996.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/comstock_deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2003/comstock_deer_2003/data/comstock_deer_2003.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/comstock_deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2007/comstock_deer_2007/data/comstock_deer_2007.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/comstock_deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2011/comstock_deer_2011/data/comstock_deer_2011.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/comstock_deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2014/comstock_deer_2014/data/comstock_deer_2014.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/comstock_deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2015/comstock_deer_2015/data/comstock_deer_2015.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/comstock_deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2017/comstock_deer_2017/data/comstock_deer_2017.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/comstock_deer_2020/comstock_deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/comstock_deer_2025/comstock_deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/comstock_deer_2030/comstock_deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/comstock_deer_2035/comstock_deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/comstock_deer_2040/comstock_deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/comstock_deer_2045/comstock_deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/comstock_deer_2050/comstock_deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/comstock_deer_2055/comstock_deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/comstock_deer_2060/comstock_deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/comstock_deer_2065/comstock_deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/comstock_deer_2070/comstock_deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/comstock_deer_2075/comstock_deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +9 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +3 -0
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +5 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/comstock_deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/comstock_deer_pre_1975/data/comstock_deer_pre_1975.ext_ltg.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/deer_pre_1975.rb +4 -0
- data/lib/openstudio-standards/standards/icc_iecc/icc_iecc_2015/icc_iecc_2015.rb +4 -0
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/btap_1980to2010.rb +6 -28
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +25 -110
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +45 -60
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +19 -23
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +84 -83
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +52 -47
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +43 -40
- data/lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json +211 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +1195 -20
- data/lib/openstudio-standards/standards/necb/ECMS/data/furnace_set.json +18 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps.json +244 -182
- data/lib/openstudio-standards/standards/necb/ECMS/data/heat_pumps_heating.json +232 -185
- data/lib/openstudio-standards/standards/necb/ECMS/data/shw_set.json +20 -2
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +18 -25
- data/lib/openstudio-standards/standards/necb/ECMS/erv.rb +12 -13
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +1647 -466
- data/lib/openstudio-standards/standards/necb/ECMS/loads.rb +93 -0
- data/lib/openstudio-standards/standards/necb/ECMS/nv.rb +40 -47
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +26 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +303 -305
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +45 -45
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +90 -120
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm +1176 -1115
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm +8279 -28923
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +1173 -1173
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +15 -13
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +32 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +25 -26
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +14 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +24 -29
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +85 -84
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +41 -42
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +209 -197
- data/lib/openstudio-standards/standards/necb/NECB2011/lighting.rb +87 -82
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +510 -406
- data/lib/openstudio-standards/standards/necb/NECB2011/nv.md +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +686 -683
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +129 -82
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +25 -18
- data/lib/openstudio-standards/standards/necb/NECB2015/lighting.rb +73 -67
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +18 -22
- data/lib/openstudio-standards/standards/necb/NECB2015/qaqc/necb_2015_qaqc.rb +59 -63
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +1608 -1608
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -4
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +10 -14
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +779 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/boilers.json +122 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +335 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/constants.json +13 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/furnaces.json +41 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +452 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_rejection.json +228 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/led_lighting_data.json +2883 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +25851 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/surface_thermal_transmittance.json +60 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +585 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb +175 -0
- data/lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md +10 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +1963 -0
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +410 -0
- data/lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/standards/necb/common/phius.md +23 -0
- data/lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json +1158 -386
- data/lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb +4 -0
- data/lib/openstudio-standards/standards/standard.rb +2 -1
- data/lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb +1 -1
- data/lib/openstudio-standards/utilities/logging.rb +6 -0
- data/lib/openstudio-standards/utilities/simulation.rb +30 -14
- data/lib/openstudio-standards/utilities/{speacetype_map_converter.rb → spacetype_map_converter.rb} +0 -0
- data/lib/openstudio-standards/utilities/sqlfile.rb +112 -71
- data/lib/openstudio-standards/version.rb +2 -2
- data/lib/openstudio-standards/weather/Weather.Model.rb +209 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +1 -1
- data/lib/openstudio-standards.rb +9 -0
- metadata +106 -205
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +0 -25426
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +0 -508
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +0 -21446
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.chillers.json +0 -293
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +0 -564
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.motors.json +0 -184
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +0 -21380
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.boilers.json +0 -49
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.chillers.json +0 -395
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.energy_recovery.json +0 -550
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +0 -466
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +0 -137
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.motors.json +0 -238
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +0 -21548
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.unitary_acs.json +0 -554
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_source_heat_pumps_heating.json +0 -12
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.boilers.json +0 -64
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.chillers.json +0 -871
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +0 -12487
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_sets.json +0 -1600
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.economizers.json +0 -592
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.elevators.json +0 -349
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +0 -1096
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ext_ltg.json +0 -164
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +0 -10663
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +0 -886
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +0 -194
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_rejection.json +0 -44
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.motors.json +0 -247
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.prototype_inputs.json +0 -3094
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_cases.json +0 -829
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ref_lnup.json +0 -562
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_compressors.json +0 -52
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_condenser.json +0 -220
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_system.json +0 -156
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.refrigeration_walkins.json +0 -1316
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +0 -22079
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.unitary_acs.json +0 -994
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +0 -68
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps.json +0 -28
- data/data/standards/export/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_source_heat_pumps_heating.json +0 -12
- data/lib/openstudio-standards/utilities/convert_costing_constructions.rb +0 -105
@@ -1,12 +1,95 @@
|
|
1
1
|
class Standard
|
2
2
|
# @!group CoilHeatingGas
|
3
3
|
|
4
|
-
# Applies the standard efficiency ratings
|
4
|
+
# Applies the standard efficiency ratings to CoilHeatingGas.
|
5
5
|
#
|
6
|
-
# @
|
6
|
+
# @param coil_heating_gas [OpenStudio::Model::CoilHeatingGas] coil heating gas object
|
7
|
+
# @return [Bool] returns true if successful, false if not
|
7
8
|
def coil_heating_gas_apply_efficiency_and_curves(coil_heating_gas)
|
8
|
-
successfully_set_all_properties =
|
9
|
+
successfully_set_all_properties = false
|
10
|
+
# Initialize search criteria
|
11
|
+
search_criteria = {}
|
12
|
+
search_criteria['template'] = template
|
13
|
+
|
14
|
+
# Get the capacity, but return false if not available
|
15
|
+
capacity_w = coil_heating_gas_find_capacity(coil_heating_gas)
|
16
|
+
|
17
|
+
# Return false if the coil does not have a heating capacity associated with it. Cannot apply the standard if without
|
18
|
+
# it.
|
19
|
+
return successfully_set_all_properties if capacity_w == false
|
20
|
+
|
21
|
+
# Convert capacity to Btu/hr
|
22
|
+
capacity_btu_per_hr = OpenStudio.convert(capacity_w, 'W', 'Btu/hr').get
|
23
|
+
capacity_kbtu_per_hr = OpenStudio.convert(capacity_w, 'W', 'kBtu/hr').get
|
24
|
+
|
25
|
+
# Get the boiler properties, if it exists for this template
|
26
|
+
return false unless standards_data.include?('furnaces')
|
27
|
+
|
28
|
+
furnace_props = model_find_object(standards_data['furnaces'], search_criteria, capacity_btu_per_hr)
|
29
|
+
unless furnace_props
|
30
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilHeatingGas', "For #{coil_heating_gas.name}, cannot find furnace properties with search criteria #{search_criteria}, cannot apply efficiency standard.")
|
31
|
+
successfully_set_all_properties = false
|
32
|
+
return successfully_set_all_properties
|
33
|
+
end
|
34
|
+
|
35
|
+
# Get the minimum efficiency standards
|
36
|
+
thermal_eff = nil
|
37
|
+
|
38
|
+
# If specified as thermal efficiency, this takes precedent
|
39
|
+
if !furnace_props['minimum_thermal_efficiency'].nil?
|
40
|
+
thermal_eff = furnace_props['minimum_thermal_efficiency']
|
41
|
+
new_comp_name = "#{coil_heating_gas.name} #{capacity_kbtu_per_hr.round}kBtu/hr #{thermal_eff} Thermal Eff"
|
42
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilHeatingGas', "For #{template}: #{coil_heating_gas.name}: = #{capacity_kbtu_per_hr.round}kBtu/hr; Thermal Efficiency = #{thermal_eff}")
|
43
|
+
|
44
|
+
else # If not thermal efficiency, check other parameters
|
45
|
+
|
46
|
+
# If specified as AFUE
|
47
|
+
unless furnace_props['minimum_annual_fuel_utilization_efficiency'].nil?
|
48
|
+
min_afue = furnace_props['minimum_annual_fuel_utilization_efficiency']
|
49
|
+
thermal_eff = afue_to_thermal_eff(min_afue)
|
50
|
+
new_comp_name = "#{coil_heating_gas.name} #{capacity_kbtu_per_hr.round}kBtu/hr #{min_afue} AFUE"
|
51
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilHeatingGas', "For #{template}: #{coil_heating_gas.name}: = #{capacity_kbtu_per_hr.round}kBtu/hr; AFUE = #{min_afue}")
|
52
|
+
end
|
53
|
+
|
54
|
+
# If specified as combustion efficiency
|
55
|
+
unless furnace_props['minimum_combustion_efficiency'].nil?
|
56
|
+
min_comb_eff = furnace_props['minimum_combustion_efficiency']
|
57
|
+
thermal_eff = combustion_eff_to_thermal_eff(min_comb_eff)
|
58
|
+
new_comp_name = "#{coil_heating_gas.name} #{capacity_kbtu_per_hr.round}kBtu/hr #{min_comb_eff} Combustion Eff"
|
59
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilHeatingGas', "For #{template}: #{coil_heating_gas.name}: = #{capacity_kbtu_per_hr.round}kBtu/hr; Combustion Efficiency = #{min_comb_eff}")
|
60
|
+
end
|
61
|
+
|
62
|
+
end
|
63
|
+
|
64
|
+
# Set the efficiency values
|
65
|
+
unless thermal_eff.nil?
|
66
|
+
|
67
|
+
# Set the name
|
68
|
+
coil_heating_gas.setName(new_comp_name)
|
69
|
+
coil_heating_gas.setGasBurnerEfficiency(thermal_eff)
|
70
|
+
successfully_set_all_properties = true
|
71
|
+
end
|
9
72
|
|
10
73
|
return successfully_set_all_properties
|
11
74
|
end
|
75
|
+
|
76
|
+
# Retrieves the capacity of an OpenStudio::Model::CoilHeatingGas in watts
|
77
|
+
#
|
78
|
+
# @param coil_heating_gas [OpenStudio::Model::CoilHeatingGas] the gas heating coil
|
79
|
+
# @return [Double, false] a double representing the capacity of the CoilHeatingGas object in watts. If unsuccessful in
|
80
|
+
# determining the capacity, this function returns false.
|
81
|
+
def coil_heating_gas_find_capacity(coil_heating_gas)
|
82
|
+
capacity_w = nil
|
83
|
+
if coil_heating_gas.nominalCapacity.is_initialized
|
84
|
+
capacity_w = coil_heating_gas.nominalCapacity.get
|
85
|
+
elsif coil_heating_gas.autosizedNominalCapacity.is_initialized
|
86
|
+
capacity_w = coil_heating_gas.autosizedNominalCapacity.get
|
87
|
+
else
|
88
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilHeatingGas', "For #{coil_heating_gas.name} capacity is not available, cannot apply efficiency standard.")
|
89
|
+
successfully_set_all_properties = false
|
90
|
+
return successfully_set_all_properties
|
91
|
+
end
|
92
|
+
|
93
|
+
return capacity_w
|
94
|
+
end
|
12
95
|
end
|
@@ -3,6 +3,7 @@ class Standard
|
|
3
3
|
|
4
4
|
# find search criteria
|
5
5
|
#
|
6
|
+
# @param coil_heating_gas_multi_stage [OpenStudio::Model::CoilHeatingGasMultiStage] coil heating gas multi stage object
|
6
7
|
# @return [Hash] used for model_find_object(model)
|
7
8
|
def coil_heating_gas_multi_stage_find_search_criteria(coil_heating_gas_multi_stage)
|
8
9
|
# Define the criteria to find the coil heating gas multi-stage properties
|
@@ -17,8 +18,9 @@ class Standard
|
|
17
18
|
|
18
19
|
# Applies the standard efficiency ratings and typical performance curves to this object.
|
19
20
|
#
|
20
|
-
# @
|
21
|
-
|
21
|
+
# @param coil_heating_gas_multi_stage [OpenStudio::Model::CoilHeatingGasMultiStage] coil heating gas multi stage object
|
22
|
+
# @return [Bool] returns true if successful, false if not
|
23
|
+
def coil_heating_gas_multi_stage_apply_efficiency_and_curves(coil_heating_gas_multi_stage)
|
22
24
|
successfully_set_all_properties = true
|
23
25
|
|
24
26
|
# Get the coil capacity
|
@@ -46,6 +48,7 @@ class Standard
|
|
46
48
|
|
47
49
|
# Finds capacity in W
|
48
50
|
#
|
51
|
+
# @param coil_heating_gas_multi_stage [OpenStudio::Model::CoilHeatingGasMultiStage] coil heating gas multi stage object
|
49
52
|
# @return [Double] capacity in W to be used for find object
|
50
53
|
def coil_heating_gas_multi_stage_find_capacity(coil_heating_gas_multi_stage)
|
51
54
|
capacity_w = nil
|
data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb
CHANGED
@@ -4,6 +4,7 @@ class Standard
|
|
4
4
|
# Finds capacity in W.
|
5
5
|
# This is the cooling capacity of the paired cooling coil.
|
6
6
|
#
|
7
|
+
# @param coil_heating_water_to_air_heat_pump [OpenStudio::Model::CoilHeatingWaterToAirHeatPumpEquationFit] coil heating object
|
7
8
|
# @return [Double] capacity in W to be used for find object
|
8
9
|
def coil_heating_water_to_air_heat_pump_find_capacity(coil_heating_water_to_air_heat_pump)
|
9
10
|
capacity_w = nil
|
@@ -86,6 +87,7 @@ class Standard
|
|
86
87
|
|
87
88
|
# Finds lookup object in standards and return efficiency
|
88
89
|
#
|
90
|
+
# @param coil_heating_water_to_air_heat_pump [OpenStudio::Model::CoilHeatingWaterToAirHeatPumpEquationFit] coil heating object
|
89
91
|
# @param rename [Bool] if true, object will be renamed to include capacity and efficiency level
|
90
92
|
# @return [Double] full load efficiency (COP)
|
91
93
|
def coil_heating_water_to_air_heat_pump_standard_minimum_cop(coil_heating_water_to_air_heat_pump, rename = false)
|
@@ -125,7 +127,9 @@ class Standard
|
|
125
127
|
|
126
128
|
# Applies the standard efficiency ratings and typical performance curves to this object.
|
127
129
|
#
|
128
|
-
# @
|
130
|
+
# @param coil_heating_water_to_air_heat_pump [OpenStudio::Model::CoilHeatingWaterToAirHeatPumpEquationFit] coil heating object
|
131
|
+
# @param sql_db_vars_map [Hash] hash map
|
132
|
+
# @return [Hash] hash of coil objects
|
129
133
|
def coil_heating_water_to_air_heat_pump_apply_efficiency_and_curves(coil_heating_water_to_air_heat_pump, sql_db_vars_map)
|
130
134
|
successfully_set_all_properties = true
|
131
135
|
|
@@ -145,7 +149,7 @@ class Standard
|
|
145
149
|
return sql_db_vars_map
|
146
150
|
end
|
147
151
|
|
148
|
-
#
|
152
|
+
# @todo Add methods to set coefficients, and add coefficients to data spreadsheet
|
149
153
|
# using OS defaults for now
|
150
154
|
# heat_cap_coeff1 = coil_props['heat_cap_coeff1']
|
151
155
|
# if heat_cap_coeff1
|
@@ -1,9 +1,9 @@
|
|
1
1
|
class Standard
|
2
2
|
# @!group Construction
|
3
3
|
|
4
|
-
# Sets the U-value of a construction to a specified value
|
5
|
-
# by modifying the thickness of the insulation layer.
|
4
|
+
# Sets the U-value of a construction to a specified value by modifying the thickness of the insulation layer.
|
6
5
|
#
|
6
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
7
7
|
# @param target_u_value_ip [Double] U-Value (Btu/ft^2*hr*R)
|
8
8
|
# @param insulation_layer_name [String] The name of the insulation layer in this construction
|
9
9
|
# @param intended_surface_type [String]
|
@@ -118,9 +118,9 @@ class Standard
|
|
118
118
|
return true
|
119
119
|
end
|
120
120
|
|
121
|
-
# Sets the U-value of a construction to a specified value
|
122
|
-
# by modifying the thickness of the insulation layer.
|
121
|
+
# Sets the U-value of a construction to a specified value by modifying the thickness of the insulation layer.
|
123
122
|
#
|
123
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
124
124
|
# @param target_u_value_ip [Double] U-Value (Btu/ft^2*hr*R)
|
125
125
|
# @param intended_surface_type [String]
|
126
126
|
# Valid choices: 'AtticFloor', 'AtticWall', 'AtticRoof', 'DemisingFloor', 'InteriorFloor', 'InteriorCeiling',
|
@@ -209,9 +209,9 @@ class Standard
|
|
209
209
|
return true
|
210
210
|
end
|
211
211
|
|
212
|
-
# Sets the U-value of a construction to a specified value
|
213
|
-
# by modifying the thickness of the insulation layer.
|
212
|
+
# Sets the U-value of a construction to a specified value by modifying the thickness of the insulation layer.
|
214
213
|
#
|
214
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
215
215
|
# @param target_shgc [Double] Solar Heat Gain Coefficient
|
216
216
|
# @return [Bool] returns true if successful, false if not
|
217
217
|
def construction_set_glazing_shgc(construction, target_shgc)
|
@@ -236,7 +236,9 @@ class Standard
|
|
236
236
|
|
237
237
|
# Determines if the construction is a simple glazing construction,
|
238
238
|
# as indicated by having a single layer of type SimpleGlazing.
|
239
|
-
#
|
239
|
+
#
|
240
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
241
|
+
# @return [Bool] returns true if it is a simple glazing, false if not
|
240
242
|
def construction_simple_glazing?(construction)
|
241
243
|
# Not simple if more than 1 layer
|
242
244
|
if construction.layers.length > 1
|
@@ -257,6 +259,7 @@ class Standard
|
|
257
259
|
# the insulation layer according to the values from 90.1-2004
|
258
260
|
# Table A6.3 Assembly F-Factors for Slab-on-Grade Floors.
|
259
261
|
#
|
262
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
260
263
|
# @param target_f_factor_ip [Double] F-Factor
|
261
264
|
# @param insulation_layer_name [String] The name of the insulation layer in this construction
|
262
265
|
# @return [Bool] returns true if successful, false if not
|
@@ -279,6 +282,7 @@ class Standard
|
|
279
282
|
# the insulation layer according to the values from 90.1-2004
|
280
283
|
# Table A4.2 Assembly C-Factors for Below-Grade walls.
|
281
284
|
#
|
285
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
282
286
|
# @param target_c_factor_ip [Double] C-Factor
|
283
287
|
# @param insulation_layer_name [String] The name of the insulation layer in this construction
|
284
288
|
# @return [Bool] returns true if successful, false if not
|
@@ -298,6 +302,8 @@ class Standard
|
|
298
302
|
|
299
303
|
# Get the SHGC as calculated by EnergyPlus.
|
300
304
|
# Only applies to fenestration constructions.
|
305
|
+
#
|
306
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
301
307
|
# @return [Double] the SHGC as a decimal.
|
302
308
|
def construction_calculated_solar_heat_gain_coefficient(construction)
|
303
309
|
construction_name = construction.name.get.to_s
|
@@ -348,6 +354,8 @@ class Standard
|
|
348
354
|
|
349
355
|
# Get the VT as calculated by EnergyPlus.
|
350
356
|
# Only applies to fenestration constructions.
|
357
|
+
#
|
358
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
351
359
|
# @return [Double] the visible transmittance as a decimal.
|
352
360
|
def construction_calculated_visible_transmittance(construction)
|
353
361
|
construction_name = construction.name.get.to_s
|
@@ -398,6 +406,8 @@ class Standard
|
|
398
406
|
|
399
407
|
# Get the U-Factor as calculated by EnergyPlus.
|
400
408
|
# Only applies to fenestration constructions.
|
409
|
+
#
|
410
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
401
411
|
# @return [Double] the U-Factor in W/m^2*K.
|
402
412
|
def construction_calculated_u_factor(construction)
|
403
413
|
construction_name = construction.name.get.to_s
|
@@ -446,39 +456,48 @@ class Standard
|
|
446
456
|
return u_factor_w_per_m2_k
|
447
457
|
end
|
448
458
|
|
459
|
+
# find and get the insulation layer for a construction
|
460
|
+
#
|
461
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
462
|
+
# @return [OpenStudio::Model::Material] insulation layer
|
449
463
|
def find_and_set_insulation_layer(construction)
|
450
464
|
# skip if already has an insulation layer set.
|
451
|
-
|
452
|
-
|
453
|
-
|
454
|
-
|
455
|
-
|
456
|
-
|
457
|
-
|
458
|
-
|
459
|
-
|
460
|
-
|
461
|
-
|
462
|
-
|
463
|
-
|
464
|
-
|
465
|
-
|
466
|
-
|
467
|
-
|
468
|
-
|
469
|
-
|
465
|
+
return construction.insulation.get unless construction.insulation.empty?
|
466
|
+
|
467
|
+
# find insulation layer
|
468
|
+
min_conductance = 100.0
|
469
|
+
# loop through Layers
|
470
|
+
construction.layers.each do |layer|
|
471
|
+
# try casting the layer to an OpaqueMaterial.
|
472
|
+
material = nil
|
473
|
+
material = layer.to_OpaqueMaterial.get unless layer.to_OpaqueMaterial.empty?
|
474
|
+
material = layer.to_FenestrationMaterial.get unless layer.to_FenestrationMaterial.empty?
|
475
|
+
# check if the cast was successful, then find the insulation layer.
|
476
|
+
unless material.nil?
|
477
|
+
|
478
|
+
if BTAP::Resources::Envelope::Materials.get_conductance(material) < min_conductance
|
479
|
+
# Keep track of the highest thermal resistance value.
|
480
|
+
min_conductance = BTAP::Resources::Envelope::Materials.get_conductance(material)
|
481
|
+
return_material = material
|
482
|
+
unless material.to_OpaqueMaterial.empty?
|
483
|
+
construction.setInsulation(material)
|
470
484
|
end
|
471
485
|
end
|
472
486
|
end
|
473
|
-
if construction.insulation.empty? && construction.isOpaque
|
474
|
-
raise
|
475
|
-
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Construction', "This construction has no insulation layer specified. Construction #{construction.name.get} insulation layer could not be set!. This occurs when a insulation layer is duplicated in the construction.")
|
476
|
-
end
|
477
|
-
else
|
478
|
-
return construction.insulation.get
|
479
487
|
end
|
488
|
+
if construction.insulation.empty? && construction.isOpaque
|
489
|
+
raise
|
490
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.Construction', "This construction has no insulation layer specified. Construction #{construction.name.get} insulation layer could not be set!. This occurs when a insulation layer is duplicated in the construction.")
|
491
|
+
end
|
492
|
+
return construction.insulation.get
|
480
493
|
end
|
481
494
|
|
495
|
+
# change construction properties based on an a set of values
|
496
|
+
#
|
497
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
498
|
+
# @param values [Hash] has of values
|
499
|
+
# @param is_percentage [Bool] toggle is percentage
|
500
|
+
# @return [Hash] json information
|
482
501
|
def change_construction_properties_in_model(model, values, is_percentage = false)
|
483
502
|
puts JSON.pretty_generate(values)
|
484
503
|
# copy orginal model for reporting.
|
@@ -532,6 +551,15 @@ class Standard
|
|
532
551
|
return info
|
533
552
|
end
|
534
553
|
|
554
|
+
# apply changes to a surface construction
|
555
|
+
#
|
556
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
557
|
+
# @param surface [OpenStudio::Model::Surface] surface object
|
558
|
+
# @param conductance [Double] conductance value in SI
|
559
|
+
# @param shgc [Double] solar heat gain coefficient value, unitless
|
560
|
+
# @param tvis [Double] visible transmittance
|
561
|
+
# @param is_percentage [Bool] toggle is percentage
|
562
|
+
# @return [Bool] returns true if successful, false if not
|
535
563
|
def apply_changes_to_surface_construction(model, surface, conductance = nil, shgc = nil, tvis = nil, is_percentage = false)
|
536
564
|
# If user has no changes...do nothing and return true.
|
537
565
|
return true if conductance.nil? && shgc.nil? && tvis.nil?
|
@@ -634,13 +662,15 @@ class Standard
|
|
634
662
|
new_construction = new_construction.get
|
635
663
|
end
|
636
664
|
surface.setConstruction(new_construction)
|
665
|
+
return true
|
637
666
|
end
|
638
667
|
|
639
668
|
# This will create a deep copy of the construction
|
640
669
|
# @author Phylroy A. Lopez <plopez@nrcan.gc.ca>
|
641
|
-
#
|
642
|
-
# @param
|
643
|
-
# @
|
670
|
+
#
|
671
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
672
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
673
|
+
# @return [OpenStudio::Model::Construction] new construction object
|
644
674
|
def construction_deep_copy(model, construction)
|
645
675
|
construction = BTAP::Common.validate_array(model, construction, 'Construction').first
|
646
676
|
new_construction = construction.clone.to_Construction.get
|
@@ -657,6 +687,7 @@ class Standard
|
|
657
687
|
# Sets the T-vis of a simple glazing construction to a specified value
|
658
688
|
# by modifying the thickness of the insulation layer.
|
659
689
|
#
|
690
|
+
# @param construction [OpenStudio::Model::Construction] construction object
|
660
691
|
# @param target_tvis [Double] Visible Transmittance
|
661
692
|
# @return [Bool] returns true if successful, false if not
|
662
693
|
def construction_set_glazing_tvis(construction, target_tvis)
|
@@ -16,7 +16,9 @@ module CoolingTower
|
|
16
16
|
# rate will not (and should not)
|
17
17
|
# exactly equal the minimum tower performance.
|
18
18
|
#
|
19
|
-
# @
|
19
|
+
# @param cooling_tower [OpenStudio::Model::StraightComponent] cooling tower object, allowable types:
|
20
|
+
# CoolingTowerSingleSpeed, CoolingTowerTwoSpeed, and CoolingTowerVariableSpeed
|
21
|
+
# @return [Bool] returns true if successful, false if not
|
20
22
|
def cooling_tower_apply_minimum_power_per_flow(cooling_tower)
|
21
23
|
# Get the design water flow rate
|
22
24
|
design_water_flow_m3_per_s = nil
|
@@ -42,7 +44,7 @@ module CoolingTower
|
|
42
44
|
# Closed cooling towers are the fluidcooler objects.
|
43
45
|
search_criteria['equipment_type'] = 'Open Cooling Tower'
|
44
46
|
|
45
|
-
#
|
47
|
+
# @todo Standards replace this with a mechanism to store this
|
46
48
|
# data in the cooling tower object itself.
|
47
49
|
# For now, retrieve the fan type from the name
|
48
50
|
name = cooling_tower.name.get
|
@@ -135,12 +137,10 @@ module CoolingTower
|
|
135
137
|
return true
|
136
138
|
end
|
137
139
|
|
138
|
-
# Above this point, centrifugal fan cooling towers must meet the limits
|
139
|
-
# of propeller or axial cooling towers instead.
|
140
|
+
# Above this point, centrifugal fan cooling towers must meet the limits of propeller or axial cooling towers instead.
|
140
141
|
#
|
141
|
-
# @param cooling_tower [OpenStudio::Model::
|
142
|
-
#
|
143
|
-
# OpenStudio::Model::CoolingTowerVariableSpeed] the cooling tower
|
142
|
+
# @param cooling_tower [OpenStudio::Model::StraightComponent] cooling tower object, allowable types:
|
143
|
+
# CoolingTowerSingleSpeed, CoolingTowerTwoSpeed, CoolingTowerVariableSpeed
|
144
144
|
# @return [Double] the limit, in gallons per minute. Return nil for no limit.
|
145
145
|
def cooling_tower_apply_minimum_power_per_flow_gpm_limit(cooling_tower)
|
146
146
|
gpm_limit = nil
|
@@ -5,10 +5,10 @@ class Standard
|
|
5
5
|
|
6
6
|
# Applies the standard efficiency ratings and typical performance curves to this object.
|
7
7
|
#
|
8
|
-
# @
|
8
|
+
# @param cooling_tower_single_speed [OpenStudio::Model::CoolingTowerSingleSpeed] single speed cooling tower
|
9
|
+
# @return [Bool] returns true if successful, false if not
|
9
10
|
def cooling_tower_single_speed_apply_efficiency_and_curves(cooling_tower_single_speed)
|
10
11
|
cooling_tower_apply_minimum_power_per_flow(cooling_tower_single_speed)
|
11
|
-
|
12
12
|
return true
|
13
13
|
end
|
14
14
|
end
|
@@ -5,7 +5,8 @@ class Standard
|
|
5
5
|
|
6
6
|
# Applies the standard efficiency ratings and typical performance curves to this object.
|
7
7
|
#
|
8
|
-
# @
|
8
|
+
# @param cooling_tower_two_speed [OpenStudio::Model::CoolingTowerTwoSpeed] two speed cooling tower
|
9
|
+
# @return [Bool] returns true if successful, false if not
|
9
10
|
def cooling_tower_two_speed_apply_efficiency_and_curves(cooling_tower_two_speed)
|
10
11
|
cooling_tower_apply_minimum_power_per_flow(cooling_tower_two_speed)
|
11
12
|
|
@@ -5,7 +5,8 @@ class Standard
|
|
5
5
|
|
6
6
|
# Applies the standard efficiency ratings and typical performance curves to this object.
|
7
7
|
#
|
8
|
-
# @
|
8
|
+
# @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] variable speed cooling tower
|
9
|
+
# @return [Bool] returns true if successful, false if not
|
9
10
|
def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
|
10
11
|
cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
|
11
12
|
return true
|
@@ -3,8 +3,12 @@
|
|
3
3
|
module Fan
|
4
4
|
# @!group Fan
|
5
5
|
|
6
|
-
# Applies the minimum motor efficiency for this fan
|
7
|
-
#
|
6
|
+
# Applies the minimum motor efficiency for this fan based on the motor's brake horsepower.
|
7
|
+
#
|
8
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
9
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
10
|
+
# @param allowed_bhp [Double] allowable brake horsepower
|
11
|
+
# @return [Bool] returns true if successful, false if not
|
8
12
|
def fan_apply_standard_minimum_motor_efficiency(fan, allowed_bhp)
|
9
13
|
# Find the motor efficiency
|
10
14
|
motor_eff, nominal_hp = fan_standard_minimum_motor_efficiency_and_size(fan, allowed_bhp)
|
@@ -32,8 +36,10 @@ module Fan
|
|
32
36
|
# Adjust the fan pressure rise to hit the target fan power (W).
|
33
37
|
# Keep the fan impeller and motor efficiencies static.
|
34
38
|
#
|
35
|
-
# @param
|
36
|
-
#
|
39
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
40
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
41
|
+
# @param target_fan_power [Double] the target fan power in watts
|
42
|
+
# @return [Bool] returns true if successful, false if not
|
37
43
|
def fan_adjust_pressure_rise_to_meet_fan_power(fan, target_fan_power)
|
38
44
|
# Get design supply air flow rate (whether autosized or hard-sized)
|
39
45
|
dsn_air_flow_m3_per_s = 0
|
@@ -67,11 +73,12 @@ module Fan
|
|
67
73
|
return true
|
68
74
|
end
|
69
75
|
|
70
|
-
# Determines the fan power (W) based on
|
71
|
-
#
|
76
|
+
# Determines the fan power (W) based on flow rate,
|
77
|
+
# pressure rise, and total fan efficiency(impeller eff * motor eff)
|
72
78
|
#
|
73
|
-
# @
|
74
|
-
#
|
79
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
80
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
81
|
+
# @return [Double] fan power in watts
|
75
82
|
def fan_fanpower(fan)
|
76
83
|
# Get design supply air flow rate (whether autosized or hard-sized)
|
77
84
|
dsn_air_flow_m3_per_s = if fan.to_FanZoneExhaust.empty?
|
@@ -104,11 +111,11 @@ module Fan
|
|
104
111
|
return fan_power_w
|
105
112
|
end
|
106
113
|
|
107
|
-
# Determines the brake horsepower of the fan
|
108
|
-
# based on fan power and fan motor efficiency.
|
114
|
+
# Determines the brake horsepower of the fan based on fan power and fan motor efficiency.
|
109
115
|
#
|
116
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
117
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
110
118
|
# @return [Double] brake horsepower
|
111
|
-
# @units horsepower (hp)
|
112
119
|
def fan_brake_horsepower(fan)
|
113
120
|
# Get the fan motor efficiency
|
114
121
|
existing_motor_eff = 0.7
|
@@ -125,11 +132,11 @@ module Fan
|
|
125
132
|
return fan_bhp
|
126
133
|
end
|
127
134
|
|
128
|
-
# Determines the horsepower of the fan
|
129
|
-
# motor, including motor efficiency and
|
130
|
-
# fan impeller efficiency.
|
135
|
+
# Determines the horsepower of the fan motor, including motor efficiency and fan impeller efficiency.
|
131
136
|
#
|
132
|
-
# @
|
137
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
138
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
139
|
+
# @return [Double] motor horsepower
|
133
140
|
def fan_motor_horsepower(fan)
|
134
141
|
# Get the fan power
|
135
142
|
fan_power_w = fan_fanpower(fan)
|
@@ -143,7 +150,10 @@ module Fan
|
|
143
150
|
# Changes the fan motor efficiency and also the fan total efficiency
|
144
151
|
# at the same time, preserving the impeller efficiency.
|
145
152
|
#
|
153
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
154
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
146
155
|
# @param motor_eff [Double] motor efficiency (0.0 to 1.0)
|
156
|
+
# @return [Bool] returns true if successful, false if not
|
147
157
|
def fan_change_motor_efficiency(fan, motor_eff)
|
148
158
|
# Calculate the existing impeller efficiency
|
149
159
|
existing_motor_eff = 0.7
|
@@ -163,12 +173,16 @@ module Fan
|
|
163
173
|
fan.setFanEfficiency(new_total_eff)
|
164
174
|
fan.setMotorEfficiency(motor_eff)
|
165
175
|
end
|
176
|
+
return true
|
166
177
|
end
|
167
178
|
|
168
179
|
# Changes the fan impeller efficiency and also the fan total efficiency
|
169
180
|
# at the same time, preserving the motor efficiency.
|
170
181
|
#
|
182
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
183
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
171
184
|
# @param impeller_eff [Double] impeller efficiency (0.0 to 1.0)
|
185
|
+
# @return [Bool] returns true if successful, false if not
|
172
186
|
def fan_change_impeller_efficiency(fan, impeller_eff)
|
173
187
|
# Get the existing motor efficiency
|
174
188
|
existing_motor_eff = 0.7
|
@@ -181,21 +195,23 @@ module Fan
|
|
181
195
|
|
182
196
|
# Set the revised motor and total fan efficiencies
|
183
197
|
fan.setFanEfficiency(new_total_eff)
|
198
|
+
return true
|
184
199
|
end
|
185
200
|
|
186
|
-
# Determines the baseline fan impeller efficiency
|
187
|
-
# based on the specified fan type.
|
201
|
+
# Determines the baseline fan impeller efficiency based on the specified fan type.
|
188
202
|
#
|
203
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
204
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
189
205
|
# @return [Double] impeller efficiency (0.0 to 1.0)
|
190
206
|
# @todo Add fan type to data model and modify this method
|
191
207
|
def fan_baseline_impeller_efficiency(fan)
|
192
208
|
# Assume that the fan efficiency is 65% for normal fans
|
193
209
|
# and 55% for small fans (like exhaust fans).
|
194
|
-
#
|
210
|
+
# @todo add fan type to fan data model
|
195
211
|
# and infer impeller efficiency from that?
|
196
212
|
# or do we always assume a certain type of
|
197
213
|
# fan impeller for the baseline system?
|
198
|
-
#
|
214
|
+
# @todo check COMNET and T24 ACM and PNNL 90.1 doc
|
199
215
|
fan_impeller_eff = 0.65
|
200
216
|
|
201
217
|
if fan_small_fan?(fan)
|
@@ -205,15 +221,16 @@ module Fan
|
|
205
221
|
return fan_impeller_eff
|
206
222
|
end
|
207
223
|
|
208
|
-
# Determines the minimum fan motor efficiency and nominal size
|
209
|
-
#
|
210
|
-
#
|
211
|
-
# the
|
212
|
-
#
|
213
|
-
#
|
214
|
-
#
|
215
|
-
# 4-pole, 1800rpm totally-enclosed fan-cooled motors.
|
224
|
+
# Determines the minimum fan motor efficiency and nominal size for a given motor bhp.
|
225
|
+
# This should be the total brake horsepower with any desired safety factor already included.
|
226
|
+
# This method picks the next nominal motor catgory larger than the required brake horsepower,
|
227
|
+
# and the efficiency is based on that size.
|
228
|
+
# For example, if the bhp = 6.3, the nominal size will be 7.5HP and the efficiency
|
229
|
+
# for 90.1-2010 will be 91.7% from Table 10.8B.
|
230
|
+
# This method assumes 4-pole, 1800rpm totally-enclosed fan-cooled motors.
|
216
231
|
#
|
232
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
233
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
217
234
|
# @param motor_bhp [Double] motor brake horsepower (hp)
|
218
235
|
# @return [Array<Double>] minimum motor efficiency (0.0 to 1.0), nominal horsepower
|
219
236
|
def fan_standard_minimum_motor_efficiency_and_size(fan, motor_bhp)
|
@@ -275,10 +292,11 @@ module Fan
|
|
275
292
|
return [fan_motor_eff, nominal_hp]
|
276
293
|
end
|
277
294
|
|
278
|
-
# Zone exhaust fans, fan coil unit fans,
|
279
|
-
# and
|
280
|
-
#
|
281
|
-
#
|
295
|
+
# Zone exhaust fans, fan coil unit fans, and powered VAV terminal fans all count
|
296
|
+
# as small fans and get different impeller efficiencies and motor efficiencies than other fans
|
297
|
+
#
|
298
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
299
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
282
300
|
# @return [Bool] returns true if it is a small fan, false if not
|
283
301
|
def fan_small_fan?(fan)
|
284
302
|
is_small = false
|
@@ -315,11 +333,11 @@ module Fan
|
|
315
333
|
return is_small
|
316
334
|
end
|
317
335
|
|
318
|
-
# Find the actual rated fan power per flow (W/CFM)
|
319
|
-
# by querying the sql file
|
336
|
+
# Find the actual rated fan power per flow (W/CFM) by querying the sql file
|
320
337
|
#
|
321
|
-
# @
|
322
|
-
#
|
338
|
+
# @param fan [OpenStudio::Model::StraightComponent] fan object, allowable types:
|
339
|
+
# FanConstantVolume, FanOnOff, FanVariableVolume, and FanZoneExhaust
|
340
|
+
# @return [Double] rated power consumption per flow in watters per cfm, W*min/ft^3
|
323
341
|
def fan_rated_w_per_cfm(fan)
|
324
342
|
# Get design power (whether autosized or hard-sized)
|
325
343
|
rated_power_w = fan.model.getAutosizedValueFromEquipmentSummary(fan, 'Fans', 'Rated Electric Power', 'W')
|