logstash-integration-snmp 4.0.0-java

Sign up to get free protection for your applications and to get access to all the features.
Files changed (324) hide show
  1. checksums.yaml +7 -0
  2. data/CHANGELOG.md +23 -0
  3. data/CONTRIBUTORS +20 -0
  4. data/Gemfile +11 -0
  5. data/LICENSE +202 -0
  6. data/README.md +89 -0
  7. data/VERSION +1 -0
  8. data/docs/index.asciidoc +202 -0
  9. data/docs/input-snmp.asciidoc +524 -0
  10. data/docs/input-snmptrap.asciidoc +392 -0
  11. data/lib/logstash/inputs/snmp.rb +369 -0
  12. data/lib/logstash/inputs/snmptrap.rb +190 -0
  13. data/lib/logstash/plugin_mixins/snmp/common.rb +197 -0
  14. data/lib/logstash-integration-snmp_jars.rb +6 -0
  15. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  16. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  17. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  18. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  19. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  20. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  21. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  22. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  23. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  24. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  25. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  26. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  27. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  28. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  29. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  30. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  31. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  32. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  33. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  34. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  35. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  36. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  37. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  38. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  39. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  40. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  41. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  42. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  43. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  44. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  45. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  46. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  47. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  48. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  49. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  50. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  51. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  52. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  53. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  54. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  55. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  56. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  57. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  58. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  59. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  60. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  61. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  62. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  63. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  64. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  65. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  66. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  67. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  68. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  69. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  70. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  71. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  72. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  73. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  74. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  75. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  76. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  77. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  78. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  79. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  80. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  81. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  82. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  83. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  84. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  85. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  86. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  87. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  88. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  89. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  90. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  91. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  92. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  93. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  94. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  95. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  96. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  97. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  98. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  99. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  100. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  101. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  102. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  103. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  104. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  105. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  106. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  107. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  108. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  109. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  110. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  111. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  112. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  113. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  114. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  115. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  116. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  117. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  118. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  119. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  120. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  121. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  122. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  123. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  124. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  125. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  126. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  127. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  128. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  129. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  130. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  131. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  132. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  133. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  134. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  135. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  136. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  137. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  138. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  139. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  140. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  141. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  142. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  143. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  144. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  145. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  146. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  147. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  148. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  149. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  150. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  151. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  152. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  153. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  154. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  155. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  156. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  157. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  158. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  159. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  160. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  161. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  162. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  163. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  164. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  165. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  166. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  167. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  168. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  169. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  170. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  171. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  172. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  173. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  174. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  175. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  176. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  177. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  178. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  179. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  180. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  181. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  182. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  183. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  184. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  185. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  186. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  187. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  188. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  189. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  190. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  191. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  192. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  193. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  194. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  195. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  196. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  197. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  198. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  199. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  200. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  201. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  202. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  203. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  204. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  205. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  206. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  207. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  208. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  209. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  210. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  211. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  212. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  213. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  214. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  215. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  216. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  217. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  218. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  219. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  220. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  221. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  222. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  223. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  224. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  225. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  226. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  227. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  228. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  229. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  230. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  231. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  232. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  233. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  234. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  235. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  236. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  237. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  238. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  239. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  240. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  241. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  242. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  243. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  244. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  245. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  246. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  247. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  248. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  249. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  250. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  251. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  252. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  253. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  254. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  255. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  256. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  257. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  258. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  259. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  260. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  261. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  262. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  263. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  264. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  265. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  266. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  267. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  268. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  269. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  270. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  271. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  272. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  273. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  274. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  275. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  276. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  277. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  278. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  279. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  280. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  281. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  282. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  283. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  284. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  285. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  286. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  287. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  288. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  289. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  290. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  291. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  292. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  293. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  294. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  295. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  296. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  297. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  298. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  299. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  300. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  301. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  302. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  303. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  304. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  305. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  306. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  307. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  308. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  309. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  310. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  311. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  312. data/lib/mibs/logstash/iso.dic +18 -0
  313. data/logstash-integration-snmp.gemspec +40 -0
  314. data/spec/fixtures/RFC1213-MIB.dic +3445 -0
  315. data/spec/fixtures/collision.dic +25 -0
  316. data/spec/integration/inputs/snmp_spec.rb +443 -0
  317. data/spec/integration/inputs/snmptrap_spec.rb +383 -0
  318. data/spec/unit/inputs/common_spec.rb +264 -0
  319. data/spec/unit/inputs/snmp_spec.rb +510 -0
  320. data/spec/unit/inputs/snmptrap_spec.rb +141 -0
  321. data/vendor/jar-dependencies/org/logstash/integrations/plugin/4.0.0/plugin-4.0.0.jar +0 -0
  322. data/vendor/jar-dependencies/org/snakeyaml/snakeyaml-engine/2.7/snakeyaml-engine-2.7.jar +0 -0
  323. data/vendor/jar-dependencies/org/snmp4j/snmp4j/3.8.0/snmp4j-3.8.0.jar +0 -0
  324. metadata +523 -0
@@ -0,0 +1,1688 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python FRAME-RELAY-DTE-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/FRAME-RELAY-DTE-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
11
+
12
+ "FRAME-RELAY-DTE-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF IPLPDN Working Group""",
17
+ "contact" :
18
+ """ Caralyn Brown
19
+ Postal: Cadia Networks, Inc.
20
+ 1 Corporate Drive
21
+ Andover, Massachusetts 01810
22
+ Tel: +1 508 689 2400 x133
23
+ E-Mail: cbrown@cadia.com
24
+
25
+ Fred Baker
26
+ Postal: Cisco Systems
27
+ 519 Lado Drive
28
+ Santa Barbara, California 93111
29
+ Tel: +1 408 526 425
30
+ E-Mail: fred@cisco.com""",
31
+ "description" :
32
+ """The MIB module to describe the use of a Frame Relay
33
+ interface by a DTE.""",
34
+ "revisions" : (
35
+ {
36
+ "date" : "1997-05-01 02:29",
37
+ "description" :
38
+ """Converted from SMIv1 to SMIv2. (Thus, indices are
39
+ read-only rather than being not-accessible.) Added
40
+ objects and made clarifications based on implementation
41
+ experience.""",
42
+ },
43
+ {
44
+ "date" : "1992-04-01 00:00",
45
+ "description" :
46
+ """Published as RFC 1315, the initial version of this MIB
47
+ module.""",
48
+ },
49
+ ),
50
+ "identity node" : "frameRelayDTE",
51
+ },
52
+
53
+ "imports" : (
54
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
55
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
56
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
57
+ {"module" : "SNMPv2-SMI", "name" : "Integer32"},
58
+ {"module" : "SNMPv2-SMI", "name" : "NOTIFICATION-TYPE"},
59
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
60
+ {"module" : "SNMPv2-TC", "name" : "RowStatus"},
61
+ {"module" : "SNMPv2-TC", "name" : "TimeStamp"},
62
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
63
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
64
+ {"module" : "SNMPv2-CONF", "name" : "NOTIFICATION-GROUP"},
65
+ {"module" : "RFC1213-MIB", "name" : "transmission"},
66
+ {"module" : "IF-MIB", "name" : "InterfaceIndex"},
67
+ ),
68
+
69
+ "typedefs" : {
70
+ "DLCI" : {
71
+ "basetype" : "Integer32",
72
+ "status" : "current",
73
+ "ranges" : [
74
+ {
75
+ "min" : "0",
76
+ "max" : "8388607"
77
+ },
78
+ ],
79
+ "range" : {
80
+ "min" : "0",
81
+ "max" : "8388607"
82
+ },
83
+ "description" :
84
+ """The range of DLCI values. Note that this varies by
85
+ interface configuration; normally, interfaces may use
86
+ 0..1023, but may be configured to use ranges as large
87
+ as 0..2^23.""",
88
+ },
89
+ }, # typedefs
90
+
91
+ "nodes" : {
92
+ "frameRelayDTE" : {
93
+ "nodetype" : "node",
94
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
95
+ "oid" : "1.3.6.1.2.1.10.32",
96
+ "status" : "current",
97
+ }, # node
98
+ "frameRelayTraps" : {
99
+ "nodetype" : "node",
100
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
101
+ "oid" : "1.3.6.1.2.1.10.32.0",
102
+ }, # node
103
+ "frDlcmiTable" : {
104
+ "nodetype" : "table",
105
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
106
+ "oid" : "1.3.6.1.2.1.10.32.1",
107
+ "status" : "current",
108
+ "description" :
109
+ """The Parameters for the Data Link Connection Management
110
+ Interface for the frame relay service on this
111
+ interface.""",
112
+ "reference" :
113
+ """American National Standard T1.617-1991, Annex D""",
114
+ }, # table
115
+ "frDlcmiEntry" : {
116
+ "nodetype" : "row",
117
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
118
+ "oid" : "1.3.6.1.2.1.10.32.1.1",
119
+ "create" : "true",
120
+ "status" : "current",
121
+ "linkage" : [
122
+ "frDlcmiIfIndex",
123
+ ],
124
+ "description" :
125
+ """The Parameters for a particular Data Link Connection
126
+ Management Interface.""",
127
+ }, # row
128
+ "frDlcmiIfIndex" : {
129
+ "nodetype" : "column",
130
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
131
+ "oid" : "1.3.6.1.2.1.10.32.1.1.1",
132
+ "status" : "current",
133
+ "syntax" : {
134
+ "type" : { "module" :"IF-MIB", "name" : "InterfaceIndex"},
135
+ },
136
+ "access" : "readonly",
137
+ "description" :
138
+ """The ifIndex value of the corresponding ifEntry.""",
139
+ }, # column
140
+ "frDlcmiState" : {
141
+ "nodetype" : "column",
142
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
143
+ "oid" : "1.3.6.1.2.1.10.32.1.1.2",
144
+ "status" : "current",
145
+ "syntax" : {
146
+ "type" : {
147
+ "basetype" : "Enumeration",
148
+ "noLmiConfigured" : {
149
+ "nodetype" : "namednumber",
150
+ "number" : "1"
151
+ },
152
+ "lmiRev1" : {
153
+ "nodetype" : "namednumber",
154
+ "number" : "2"
155
+ },
156
+ "ansiT1617D" : {
157
+ "nodetype" : "namednumber",
158
+ "number" : "3"
159
+ },
160
+ "ansiT1617B" : {
161
+ "nodetype" : "namednumber",
162
+ "number" : "4"
163
+ },
164
+ "itut933A" : {
165
+ "nodetype" : "namednumber",
166
+ "number" : "5"
167
+ },
168
+ "ansiT1617D1994" : {
169
+ "nodetype" : "namednumber",
170
+ "number" : "6"
171
+ },
172
+ },
173
+ },
174
+ "access" : "readwrite",
175
+ "description" :
176
+ """This variable states which Data Link Connection
177
+ Management scheme is active (and by implication, what
178
+ DLCI it uses) on the Frame Relay interface.""",
179
+ "reference" :
180
+ """American National Standard T1.617-1991, American
181
+ National Standard T1.617a-1994, ITU-T Recommendation
182
+ Q.933 (03/93).""",
183
+ }, # column
184
+ "frDlcmiAddress" : {
185
+ "nodetype" : "column",
186
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
187
+ "oid" : "1.3.6.1.2.1.10.32.1.1.3",
188
+ "status" : "current",
189
+ "syntax" : {
190
+ "type" : {
191
+ "basetype" : "Enumeration",
192
+ "q921" : {
193
+ "nodetype" : "namednumber",
194
+ "number" : "1"
195
+ },
196
+ "q922March90" : {
197
+ "nodetype" : "namednumber",
198
+ "number" : "2"
199
+ },
200
+ "q922November90" : {
201
+ "nodetype" : "namednumber",
202
+ "number" : "3"
203
+ },
204
+ "q922" : {
205
+ "nodetype" : "namednumber",
206
+ "number" : "4"
207
+ },
208
+ },
209
+ },
210
+ "access" : "readwrite",
211
+ "description" :
212
+ """This variable states which address format is in use on
213
+ the Frame Relay interface.""",
214
+ }, # column
215
+ "frDlcmiAddressLen" : {
216
+ "nodetype" : "column",
217
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
218
+ "oid" : "1.3.6.1.2.1.10.32.1.1.4",
219
+ "status" : "current",
220
+ "syntax" : {
221
+ "type" : {
222
+ "basetype" : "Enumeration",
223
+ "twoOctets" : {
224
+ "nodetype" : "namednumber",
225
+ "number" : "2"
226
+ },
227
+ "threeOctets" : {
228
+ "nodetype" : "namednumber",
229
+ "number" : "3"
230
+ },
231
+ "fourOctets" : {
232
+ "nodetype" : "namednumber",
233
+ "number" : "4"
234
+ },
235
+ },
236
+ },
237
+ "access" : "readwrite",
238
+ "description" :
239
+ """This variable states the address length in octets. In
240
+ the case of Q922 format, the length indicates the
241
+ entire length of the address including the control
242
+ portion.""",
243
+ }, # column
244
+ "frDlcmiPollingInterval" : {
245
+ "nodetype" : "column",
246
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
247
+ "oid" : "1.3.6.1.2.1.10.32.1.1.5",
248
+ "status" : "current",
249
+ "syntax" : {
250
+ "type" : {
251
+ "basetype" : "Integer32",
252
+ "ranges" : [
253
+ {
254
+ "min" : "5",
255
+ "max" : "30"
256
+ },
257
+ ],
258
+ "range" : {
259
+ "min" : "5",
260
+ "max" : "30"
261
+ },
262
+ },
263
+ },
264
+ "access" : "readwrite",
265
+ "default" : "10",
266
+ "units" : "seconds",
267
+ "description" :
268
+ """This is the number of seconds between successive
269
+ status enquiry messages.""",
270
+ "reference" :
271
+ """American National Standard T1.617-1991, Section D.7
272
+ Timer T391.""",
273
+ }, # column
274
+ "frDlcmiFullEnquiryInterval" : {
275
+ "nodetype" : "column",
276
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
277
+ "oid" : "1.3.6.1.2.1.10.32.1.1.6",
278
+ "status" : "current",
279
+ "syntax" : {
280
+ "type" : {
281
+ "basetype" : "Integer32",
282
+ "ranges" : [
283
+ {
284
+ "min" : "1",
285
+ "max" : "255"
286
+ },
287
+ ],
288
+ "range" : {
289
+ "min" : "1",
290
+ "max" : "255"
291
+ },
292
+ },
293
+ },
294
+ "access" : "readwrite",
295
+ "default" : "6",
296
+ "description" :
297
+ """Number of status enquiry intervals that pass before
298
+ issuance of a full status enquiry message.""",
299
+ "reference" :
300
+ """American National Standard T1.617-1991, Section D.7
301
+ Counter N391.""",
302
+ }, # column
303
+ "frDlcmiErrorThreshold" : {
304
+ "nodetype" : "column",
305
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
306
+ "oid" : "1.3.6.1.2.1.10.32.1.1.7",
307
+ "status" : "current",
308
+ "syntax" : {
309
+ "type" : {
310
+ "basetype" : "Integer32",
311
+ "ranges" : [
312
+ {
313
+ "min" : "1",
314
+ "max" : "10"
315
+ },
316
+ ],
317
+ "range" : {
318
+ "min" : "1",
319
+ "max" : "10"
320
+ },
321
+ },
322
+ },
323
+ "access" : "readwrite",
324
+ "default" : "3",
325
+ "description" :
326
+ """This is the maximum number of unanswered Status
327
+ Enquiries the equipment shall accept before declaring
328
+ the interface down.""",
329
+ "reference" :
330
+ """American National Standard T1.617-1991, Section D.5.1
331
+ Counter N392.""",
332
+ }, # column
333
+ "frDlcmiMonitoredEvents" : {
334
+ "nodetype" : "column",
335
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
336
+ "oid" : "1.3.6.1.2.1.10.32.1.1.8",
337
+ "status" : "current",
338
+ "syntax" : {
339
+ "type" : {
340
+ "basetype" : "Integer32",
341
+ "ranges" : [
342
+ {
343
+ "min" : "1",
344
+ "max" : "10"
345
+ },
346
+ ],
347
+ "range" : {
348
+ "min" : "1",
349
+ "max" : "10"
350
+ },
351
+ },
352
+ },
353
+ "access" : "readwrite",
354
+ "default" : "4",
355
+ "description" :
356
+ """This is the number of status polling intervals over
357
+ which the error threshold is counted. For example, if
358
+ within 'MonitoredEvents' number of events the station
359
+ receives 'ErrorThreshold' number of errors, the
360
+ interface is marked as down.""",
361
+ "reference" :
362
+ """American National Standard T1.617-1991, Section D.5.2
363
+ Counter N393.""",
364
+ }, # column
365
+ "frDlcmiMaxSupportedVCs" : {
366
+ "nodetype" : "column",
367
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
368
+ "oid" : "1.3.6.1.2.1.10.32.1.1.9",
369
+ "status" : "current",
370
+ "syntax" : {
371
+ "type" : { "module" :"FRAME-RELAY-DTE-MIB", "name" : "DLCI"},
372
+ },
373
+ "access" : "readwrite",
374
+ "description" :
375
+ """The maximum number of Virtual Circuits allowed for
376
+ this interface. Usually dictated by the Frame Relay
377
+ network.
378
+
379
+ In response to a SET, if a value less than zero or
380
+ higher than the agent's maximal capability is
381
+ configured, the agent should respond badValue""",
382
+ }, # column
383
+ "frDlcmiMulticast" : {
384
+ "nodetype" : "column",
385
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
386
+ "oid" : "1.3.6.1.2.1.10.32.1.1.10",
387
+ "status" : "current",
388
+ "syntax" : {
389
+ "type" : {
390
+ "basetype" : "Enumeration",
391
+ "nonBroadcast" : {
392
+ "nodetype" : "namednumber",
393
+ "number" : "1"
394
+ },
395
+ "broadcast" : {
396
+ "nodetype" : "namednumber",
397
+ "number" : "2"
398
+ },
399
+ },
400
+ },
401
+ "access" : "readwrite",
402
+ "description" :
403
+ """This indicates whether the Frame Relay interface is
404
+ using a multicast service.""",
405
+ }, # column
406
+ "frDlcmiStatus" : {
407
+ "nodetype" : "column",
408
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
409
+ "oid" : "1.3.6.1.2.1.10.32.1.1.11",
410
+ "status" : "current",
411
+ "syntax" : {
412
+ "type" : {
413
+ "basetype" : "Enumeration",
414
+ "running" : {
415
+ "nodetype" : "namednumber",
416
+ "number" : "1"
417
+ },
418
+ "fault" : {
419
+ "nodetype" : "namednumber",
420
+ "number" : "2"
421
+ },
422
+ "initializing" : {
423
+ "nodetype" : "namednumber",
424
+ "number" : "3"
425
+ },
426
+ },
427
+ },
428
+ "access" : "readonly",
429
+ "description" :
430
+ """This indicates the status of the Frame Relay interface
431
+ as determined by the performance of the dlcmi. If no
432
+ dlcmi is running, the Frame Relay interface will stay
433
+ in the running state indefinitely.""",
434
+ }, # column
435
+ "frDlcmiRowStatus" : {
436
+ "nodetype" : "column",
437
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
438
+ "oid" : "1.3.6.1.2.1.10.32.1.1.12",
439
+ "status" : "current",
440
+ "syntax" : {
441
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
442
+ },
443
+ "access" : "readwrite",
444
+ "description" :
445
+ """SNMP Version 2 Row Status Variable. Writable objects
446
+ in the table may be written in any RowStatus state.""",
447
+ }, # column
448
+ "frCircuitTable" : {
449
+ "nodetype" : "table",
450
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
451
+ "oid" : "1.3.6.1.2.1.10.32.2",
452
+ "status" : "current",
453
+ "description" :
454
+ """A table containing information about specific Data
455
+ Link Connections (DLC) or virtual circuits.""",
456
+ }, # table
457
+ "frCircuitEntry" : {
458
+ "nodetype" : "row",
459
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
460
+ "oid" : "1.3.6.1.2.1.10.32.2.1",
461
+ "create" : "true",
462
+ "status" : "current",
463
+ "linkage" : [
464
+ "frCircuitIfIndex",
465
+ "frCircuitDlci",
466
+ ],
467
+ "description" :
468
+ """The information regarding a single Data Link
469
+ Connection. Discontinuities in the counters contained
470
+ in this table are indicated by the value in
471
+ frCircuitCreationTime.""",
472
+ }, # row
473
+ "frCircuitIfIndex" : {
474
+ "nodetype" : "column",
475
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
476
+ "oid" : "1.3.6.1.2.1.10.32.2.1.1",
477
+ "status" : "current",
478
+ "syntax" : {
479
+ "type" : { "module" :"IF-MIB", "name" : "InterfaceIndex"},
480
+ },
481
+ "access" : "readonly",
482
+ "description" :
483
+ """The ifIndex Value of the ifEntry this virtual circuit
484
+ is layered onto.""",
485
+ }, # column
486
+ "frCircuitDlci" : {
487
+ "nodetype" : "column",
488
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
489
+ "oid" : "1.3.6.1.2.1.10.32.2.1.2",
490
+ "status" : "current",
491
+ "syntax" : {
492
+ "type" : { "module" :"FRAME-RELAY-DTE-MIB", "name" : "DLCI"},
493
+ },
494
+ "access" : "readonly",
495
+ "description" :
496
+ """The Data Link Connection Identifier for this virtual
497
+ circuit.""",
498
+ "reference" :
499
+ """American National Standard T1.618-1991, Section 3.3.6""",
500
+ }, # column
501
+ "frCircuitState" : {
502
+ "nodetype" : "column",
503
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
504
+ "oid" : "1.3.6.1.2.1.10.32.2.1.3",
505
+ "status" : "current",
506
+ "syntax" : {
507
+ "type" : {
508
+ "basetype" : "Enumeration",
509
+ "invalid" : {
510
+ "nodetype" : "namednumber",
511
+ "number" : "1"
512
+ },
513
+ "active" : {
514
+ "nodetype" : "namednumber",
515
+ "number" : "2"
516
+ },
517
+ "inactive" : {
518
+ "nodetype" : "namednumber",
519
+ "number" : "3"
520
+ },
521
+ },
522
+ },
523
+ "access" : "readwrite",
524
+ "default" : "active",
525
+ "description" :
526
+ """Indicates whether the particular virtual circuit is
527
+ operational. In the absence of a Data Link Connection
528
+ Management Interface, virtual circuit entries (rows)
529
+ may be created by setting virtual circuit state to
530
+ 'active', or deleted by changing Circuit state to
531
+ 'invalid'.
532
+
533
+ Whether or not the row actually disappears is left to
534
+ the implementation, so this object may actually read as
535
+ 'invalid' for some arbitrary length of time. It is
536
+ also legal to set the state of a virtual circuit to
537
+ 'inactive' to temporarily disable a given circuit.
538
+
539
+ The use of 'invalid' is deprecated in this SNMP Version
540
+ 2 MIB, in favor of frCircuitRowStatus.""",
541
+ }, # column
542
+ "frCircuitReceivedFECNs" : {
543
+ "nodetype" : "column",
544
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
545
+ "oid" : "1.3.6.1.2.1.10.32.2.1.4",
546
+ "status" : "current",
547
+ "syntax" : {
548
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
549
+ },
550
+ "access" : "readonly",
551
+ "description" :
552
+ """Number of frames received from the network indicating
553
+ forward congestion since the virtual circuit was
554
+ created. This occurs when the remote DTE sets the FECN
555
+ flag, or when a switch in the network enqueues the
556
+ frame to a trunk whose transmission queue is
557
+ congested.""",
558
+ "reference" :
559
+ """American National Standard T1.618-1991, Section 3.3.3""",
560
+ }, # column
561
+ "frCircuitReceivedBECNs" : {
562
+ "nodetype" : "column",
563
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
564
+ "oid" : "1.3.6.1.2.1.10.32.2.1.5",
565
+ "status" : "current",
566
+ "syntax" : {
567
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
568
+ },
569
+ "access" : "readonly",
570
+ "description" :
571
+ """Number of frames received from the network indicating
572
+ backward congestion since the virtual circuit was
573
+ created. This occurs when the remote DTE sets the BECN
574
+ flag, or when a switch in the network receives the
575
+ frame from a trunk whose transmission queue is
576
+ congested.""",
577
+ "reference" :
578
+ """American National Standard T1.618-1991, Section 3.3.4""",
579
+ }, # column
580
+ "frCircuitSentFrames" : {
581
+ "nodetype" : "column",
582
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
583
+ "oid" : "1.3.6.1.2.1.10.32.2.1.6",
584
+ "status" : "current",
585
+ "syntax" : {
586
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
587
+ },
588
+ "access" : "readonly",
589
+ "description" :
590
+ """The number of frames sent from this virtual circuit
591
+ since it was created.""",
592
+ }, # column
593
+ "frCircuitSentOctets" : {
594
+ "nodetype" : "column",
595
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
596
+ "oid" : "1.3.6.1.2.1.10.32.2.1.7",
597
+ "status" : "current",
598
+ "syntax" : {
599
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
600
+ },
601
+ "access" : "readonly",
602
+ "description" :
603
+ """The number of octets sent from this virtual circuit
604
+ since it was created. Octets counted are the full
605
+ frame relay header and the payload, but do not include
606
+ the flag characters or CRC.""",
607
+ }, # column
608
+ "frCircuitReceivedFrames" : {
609
+ "nodetype" : "column",
610
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
611
+ "oid" : "1.3.6.1.2.1.10.32.2.1.8",
612
+ "status" : "current",
613
+ "syntax" : {
614
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
615
+ },
616
+ "access" : "readonly",
617
+ "description" :
618
+ """Number of frames received over this virtual circuit
619
+ since it was created.""",
620
+ }, # column
621
+ "frCircuitReceivedOctets" : {
622
+ "nodetype" : "column",
623
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
624
+ "oid" : "1.3.6.1.2.1.10.32.2.1.9",
625
+ "status" : "current",
626
+ "syntax" : {
627
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
628
+ },
629
+ "access" : "readonly",
630
+ "description" :
631
+ """Number of octets received over this virtual circuit
632
+ since it was created. Octets counted include the full
633
+ frame relay header, but do not include the flag
634
+ characters or the CRC.""",
635
+ }, # column
636
+ "frCircuitCreationTime" : {
637
+ "nodetype" : "column",
638
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
639
+ "oid" : "1.3.6.1.2.1.10.32.2.1.10",
640
+ "status" : "current",
641
+ "syntax" : {
642
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
643
+ },
644
+ "access" : "readonly",
645
+ "description" :
646
+ """The value of sysUpTime when the virtual circuit was
647
+ created, whether by the Data Link Connection Management
648
+ Interface or by a SetRequest.""",
649
+ }, # column
650
+ "frCircuitLastTimeChange" : {
651
+ "nodetype" : "column",
652
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
653
+ "oid" : "1.3.6.1.2.1.10.32.2.1.11",
654
+ "status" : "current",
655
+ "syntax" : {
656
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
657
+ },
658
+ "access" : "readonly",
659
+ "description" :
660
+ """The value of sysUpTime when last there was a change in
661
+ the virtual circuit state""",
662
+ }, # column
663
+ "frCircuitCommittedBurst" : {
664
+ "nodetype" : "column",
665
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
666
+ "oid" : "1.3.6.1.2.1.10.32.2.1.12",
667
+ "status" : "current",
668
+ "syntax" : {
669
+ "type" : {
670
+ "basetype" : "Integer32",
671
+ "ranges" : [
672
+ {
673
+ "min" : "0",
674
+ "max" : "2147483647"
675
+ },
676
+ ],
677
+ "range" : {
678
+ "min" : "0",
679
+ "max" : "2147483647"
680
+ },
681
+ },
682
+ },
683
+ "access" : "readwrite",
684
+ "default" : "0",
685
+ "description" :
686
+ """This variable indicates the maximum amount of data, in
687
+ bits, that the network agrees to transfer under normal
688
+ conditions, during the measurement interval.""",
689
+ "reference" :
690
+ """American National Standard T1.617-1991, Section
691
+ 6.5.19""",
692
+ }, # column
693
+ "frCircuitExcessBurst" : {
694
+ "nodetype" : "column",
695
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
696
+ "oid" : "1.3.6.1.2.1.10.32.2.1.13",
697
+ "status" : "current",
698
+ "syntax" : {
699
+ "type" : {
700
+ "basetype" : "Integer32",
701
+ "ranges" : [
702
+ {
703
+ "min" : "0",
704
+ "max" : "2147483647"
705
+ },
706
+ ],
707
+ "range" : {
708
+ "min" : "0",
709
+ "max" : "2147483647"
710
+ },
711
+ },
712
+ },
713
+ "access" : "readwrite",
714
+ "description" :
715
+ """This variable indicates the maximum amount of
716
+ uncommitted data bits that the network will attempt to
717
+ deliver over the measurement interval.
718
+
719
+ By default, if not configured when creating the entry,
720
+ the Excess Information Burst Size is set to the value
721
+ of ifSpeed.""",
722
+ "reference" :
723
+ """American National Standard T1.617-1991, Section
724
+ 6.5.19""",
725
+ }, # column
726
+ "frCircuitThroughput" : {
727
+ "nodetype" : "column",
728
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
729
+ "oid" : "1.3.6.1.2.1.10.32.2.1.14",
730
+ "status" : "current",
731
+ "syntax" : {
732
+ "type" : {
733
+ "basetype" : "Integer32",
734
+ "ranges" : [
735
+ {
736
+ "min" : "0",
737
+ "max" : "2147483647"
738
+ },
739
+ ],
740
+ "range" : {
741
+ "min" : "0",
742
+ "max" : "2147483647"
743
+ },
744
+ },
745
+ },
746
+ "access" : "readwrite",
747
+ "default" : "0",
748
+ "description" :
749
+ """Throughput is the average number of 'Frame Relay
750
+ Information Field' bits transferred per second across a
751
+ user network interface in one direction, measured over
752
+ the measurement interval.
753
+
754
+ If the configured committed burst rate and throughput
755
+ are both non-zero, the measurement interval, T, is
756
+ T=frCircuitCommittedBurst/frCircuitThroughput.
757
+
758
+ If the configured committed burst rate and throughput
759
+ are both zero, the measurement interval, T, is
760
+ T=frCircuitExcessBurst/ifSpeed.""",
761
+ "reference" :
762
+ """American National Standard T1.617-1991, Section
763
+ 6.5.19""",
764
+ }, # column
765
+ "frCircuitMulticast" : {
766
+ "nodetype" : "column",
767
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
768
+ "oid" : "1.3.6.1.2.1.10.32.2.1.15",
769
+ "status" : "current",
770
+ "syntax" : {
771
+ "type" : {
772
+ "basetype" : "Enumeration",
773
+ "unicast" : {
774
+ "nodetype" : "namednumber",
775
+ "number" : "1"
776
+ },
777
+ "oneWay" : {
778
+ "nodetype" : "namednumber",
779
+ "number" : "2"
780
+ },
781
+ "twoWay" : {
782
+ "nodetype" : "namednumber",
783
+ "number" : "3"
784
+ },
785
+ "nWay" : {
786
+ "nodetype" : "namednumber",
787
+ "number" : "4"
788
+ },
789
+ },
790
+ },
791
+ "access" : "readwrite",
792
+ "default" : "unicast",
793
+ "description" :
794
+ """This indicates whether this VC is used as a unicast VC
795
+ (i.e. not multicast) or the type of multicast service
796
+ subscribed to""",
797
+ "reference" :
798
+ """Frame Relay PVC Multicast Service and Protocol
799
+ Description Implementation: FRF.7 Frame Relay Forum
800
+ Technical Committe October 21, 1994""",
801
+ }, # column
802
+ "frCircuitType" : {
803
+ "nodetype" : "column",
804
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
805
+ "oid" : "1.3.6.1.2.1.10.32.2.1.16",
806
+ "status" : "current",
807
+ "syntax" : {
808
+ "type" : {
809
+ "basetype" : "Enumeration",
810
+ "static" : {
811
+ "nodetype" : "namednumber",
812
+ "number" : "1"
813
+ },
814
+ "dynamic" : {
815
+ "nodetype" : "namednumber",
816
+ "number" : "2"
817
+ },
818
+ },
819
+ },
820
+ "access" : "readonly",
821
+ "description" :
822
+ """Indication of whether the VC was manually created
823
+ (static), or dynamically created (dynamic) via the data
824
+ link control management interface.""",
825
+ }, # column
826
+ "frCircuitDiscards" : {
827
+ "nodetype" : "column",
828
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
829
+ "oid" : "1.3.6.1.2.1.10.32.2.1.17",
830
+ "status" : "current",
831
+ "syntax" : {
832
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
833
+ },
834
+ "access" : "readonly",
835
+ "description" :
836
+ """The number of inbound frames dropped because of format
837
+ errors, or because the VC is inactive.""",
838
+ }, # column
839
+ "frCircuitReceivedDEs" : {
840
+ "nodetype" : "column",
841
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
842
+ "oid" : "1.3.6.1.2.1.10.32.2.1.18",
843
+ "status" : "current",
844
+ "syntax" : {
845
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
846
+ },
847
+ "access" : "readonly",
848
+ "description" :
849
+ """Number of frames received from the network indicating
850
+ that they were eligible for discard since the virtual
851
+ circuit was created. This occurs when the remote DTE
852
+ sets the DE flag, or when in remote DTE's switch
853
+ detects that the frame was received as Excess Burst
854
+ data.""",
855
+ "reference" :
856
+ """American National Standard T1.618-1991, Section 3.3.4""",
857
+ }, # column
858
+ "frCircuitSentDEs" : {
859
+ "nodetype" : "column",
860
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
861
+ "oid" : "1.3.6.1.2.1.10.32.2.1.19",
862
+ "status" : "current",
863
+ "syntax" : {
864
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
865
+ },
866
+ "access" : "readonly",
867
+ "description" :
868
+ """Number of frames sent to the network indicating that
869
+ they were eligible for discard since the virtual
870
+ circuit was created. This occurs when the local DTE
871
+ sets the DE flag, indicating that during Network
872
+ congestion situations those frames should be discarded
873
+ in preference of other frames sent without the DE bit
874
+ set.""",
875
+ "reference" :
876
+ """American National Standard T1.618-1991, Section
877
+ 3.3.4""",
878
+ }, # column
879
+ "frCircuitLogicalIfIndex" : {
880
+ "nodetype" : "column",
881
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
882
+ "oid" : "1.3.6.1.2.1.10.32.2.1.20",
883
+ "status" : "current",
884
+ "syntax" : {
885
+ "type" : { "module" :"IF-MIB", "name" : "InterfaceIndex"},
886
+ },
887
+ "access" : "readwrite",
888
+ "description" :
889
+ """Normally the same value as frDlcmiIfIndex, but
890
+ different when an implementation associates a virtual
891
+ ifEntry with a DLC or set of DLCs in order to associate
892
+ higher layer objects such as the ipAddrEntry with a
893
+ subset of the virtual circuits on a Frame Relay
894
+ interface. The type of such ifEntries is defined by the
895
+ higher layer object; for example, if PPP/Frame Relay is
896
+ implemented, the ifType of this ifEntry would be PPP.
897
+ If it is not so defined, as would be the case with an
898
+ ipAddrEntry, it should be of type Other.""",
899
+ }, # column
900
+ "frCircuitRowStatus" : {
901
+ "nodetype" : "column",
902
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
903
+ "oid" : "1.3.6.1.2.1.10.32.2.1.21",
904
+ "status" : "current",
905
+ "syntax" : {
906
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
907
+ },
908
+ "access" : "readwrite",
909
+ "description" :
910
+ """This object is used to create a new row or modify or
911
+ destroy an existing row in the manner described in the
912
+ definition of the RowStatus textual convention.
913
+ Writable objects in the table may be written in any
914
+ RowStatus state.""",
915
+ }, # column
916
+ "frErrTable" : {
917
+ "nodetype" : "table",
918
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
919
+ "oid" : "1.3.6.1.2.1.10.32.3",
920
+ "status" : "current",
921
+ "description" :
922
+ """A table containing information about Errors on the
923
+ Frame Relay interface. Discontinuities in the counters
924
+ contained in this table are the same as apply to the
925
+ ifEntry associated with the Interface.""",
926
+ }, # table
927
+ "frErrEntry" : {
928
+ "nodetype" : "row",
929
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
930
+ "oid" : "1.3.6.1.2.1.10.32.3.1",
931
+ "status" : "current",
932
+ "linkage" : [
933
+ "frErrIfIndex",
934
+ ],
935
+ "description" :
936
+ """The error information for a single frame relay
937
+ interface.""",
938
+ }, # row
939
+ "frErrIfIndex" : {
940
+ "nodetype" : "column",
941
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
942
+ "oid" : "1.3.6.1.2.1.10.32.3.1.1",
943
+ "status" : "current",
944
+ "syntax" : {
945
+ "type" : { "module" :"IF-MIB", "name" : "InterfaceIndex"},
946
+ },
947
+ "access" : "readonly",
948
+ "description" :
949
+ """The ifIndex Value of the corresponding ifEntry.""",
950
+ }, # column
951
+ "frErrType" : {
952
+ "nodetype" : "column",
953
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
954
+ "oid" : "1.3.6.1.2.1.10.32.3.1.2",
955
+ "status" : "current",
956
+ "syntax" : {
957
+ "type" : {
958
+ "basetype" : "Enumeration",
959
+ "unknownError" : {
960
+ "nodetype" : "namednumber",
961
+ "number" : "1"
962
+ },
963
+ "receiveShort" : {
964
+ "nodetype" : "namednumber",
965
+ "number" : "2"
966
+ },
967
+ "receiveLong" : {
968
+ "nodetype" : "namednumber",
969
+ "number" : "3"
970
+ },
971
+ "illegalAddress" : {
972
+ "nodetype" : "namednumber",
973
+ "number" : "4"
974
+ },
975
+ "unknownAddress" : {
976
+ "nodetype" : "namednumber",
977
+ "number" : "5"
978
+ },
979
+ "dlcmiProtoErr" : {
980
+ "nodetype" : "namednumber",
981
+ "number" : "6"
982
+ },
983
+ "dlcmiUnknownIE" : {
984
+ "nodetype" : "namednumber",
985
+ "number" : "7"
986
+ },
987
+ "dlcmiSequenceErr" : {
988
+ "nodetype" : "namednumber",
989
+ "number" : "8"
990
+ },
991
+ "dlcmiUnknownRpt" : {
992
+ "nodetype" : "namednumber",
993
+ "number" : "9"
994
+ },
995
+ "noErrorSinceReset" : {
996
+ "nodetype" : "namednumber",
997
+ "number" : "10"
998
+ },
999
+ },
1000
+ },
1001
+ "access" : "readonly",
1002
+ "description" :
1003
+ """The type of error that was last seen on this interface:
1004
+
1005
+ receiveShort: frame was not long enough to allow
1006
+ demultiplexing - the address field was incomplete,
1007
+ or for virtual circuits using Multiprotocol over
1008
+ Frame Relay, the protocol identifier was missing
1009
+ or incomplete.
1010
+
1011
+ receiveLong: frame exceeded maximum length configured for this
1012
+ interface.
1013
+
1014
+ illegalAddress: address field did not match configured format.
1015
+
1016
+ unknownAddress: frame received on a virtual circuit which was not
1017
+ active or administratively disabled.
1018
+
1019
+ dlcmiProtoErr: unspecified error occurred when attempting to
1020
+ interpret link maintenance frame.
1021
+
1022
+ dlcmiUnknownIE: link maintenance frame contained an Information
1023
+ Element type which is not valid for the
1024
+ configured link maintenance protocol.
1025
+
1026
+ dlcmiSequenceErr: link maintenance frame contained a sequence
1027
+ number other than the expected value.
1028
+
1029
+ dlcmiUnknownRpt: link maintenance frame contained a Report Type
1030
+ Information Element whose value was not valid
1031
+ for the configured link maintenance protocol.
1032
+
1033
+ noErrorSinceReset: no errors have been detected since the last
1034
+ cold start or warm start.""",
1035
+ }, # column
1036
+ "frErrData" : {
1037
+ "nodetype" : "column",
1038
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1039
+ "oid" : "1.3.6.1.2.1.10.32.3.1.3",
1040
+ "status" : "current",
1041
+ "syntax" : {
1042
+ "type" : {
1043
+ "basetype" : "OctetString",
1044
+ "ranges" : [
1045
+ {
1046
+ "min" : "1",
1047
+ "max" : "1600"
1048
+ },
1049
+ ],
1050
+ "range" : {
1051
+ "min" : "1",
1052
+ "max" : "1600"
1053
+ },
1054
+ },
1055
+ },
1056
+ "access" : "readonly",
1057
+ "description" :
1058
+ """An octet string containing as much of the error packet
1059
+ as possible. As a minimum, it must contain the Q.922
1060
+ Address or as much as was delivered. It is desirable
1061
+ to include all header and demultiplexing information.""",
1062
+ }, # column
1063
+ "frErrTime" : {
1064
+ "nodetype" : "column",
1065
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1066
+ "oid" : "1.3.6.1.2.1.10.32.3.1.4",
1067
+ "status" : "current",
1068
+ "syntax" : {
1069
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1070
+ },
1071
+ "access" : "readonly",
1072
+ "description" :
1073
+ """The value of sysUpTime at which the error was
1074
+ detected.""",
1075
+ }, # column
1076
+ "frErrFaults" : {
1077
+ "nodetype" : "column",
1078
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1079
+ "oid" : "1.3.6.1.2.1.10.32.3.1.5",
1080
+ "status" : "current",
1081
+ "syntax" : {
1082
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1083
+ },
1084
+ "access" : "readonly",
1085
+ "description" :
1086
+ """The number of times the interface has gone down since
1087
+ it was initialized.""",
1088
+ }, # column
1089
+ "frErrFaultTime" : {
1090
+ "nodetype" : "column",
1091
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1092
+ "oid" : "1.3.6.1.2.1.10.32.3.1.6",
1093
+ "status" : "current",
1094
+ "syntax" : {
1095
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
1096
+ },
1097
+ "access" : "readonly",
1098
+ "description" :
1099
+ """The value of sysUpTime at the time when the interface
1100
+ was taken down due to excessive errors. Excessive
1101
+ errors is defined as the time when a DLCMI exceeds the
1102
+ frDlcmiErrorThreshold number of errors within
1103
+ frDlcmiMonitoredEvents. See FrDlcmiEntry for further
1104
+ details.""",
1105
+ }, # column
1106
+ "frameRelayTrapControl" : {
1107
+ "nodetype" : "node",
1108
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1109
+ "oid" : "1.3.6.1.2.1.10.32.4",
1110
+ }, # node
1111
+ "frTrapState" : {
1112
+ "nodetype" : "scalar",
1113
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1114
+ "oid" : "1.3.6.1.2.1.10.32.4.1",
1115
+ "status" : "current",
1116
+ "syntax" : {
1117
+ "type" : {
1118
+ "basetype" : "Enumeration",
1119
+ "enabled" : {
1120
+ "nodetype" : "namednumber",
1121
+ "number" : "1"
1122
+ },
1123
+ "disabled" : {
1124
+ "nodetype" : "namednumber",
1125
+ "number" : "2"
1126
+ },
1127
+ },
1128
+ },
1129
+ "access" : "readwrite",
1130
+ "default" : "disabled",
1131
+ "description" :
1132
+ """This variable indicates whether the system produces
1133
+ the frDLCIStatusChange trap.""",
1134
+ }, # scalar
1135
+ "frTrapMaxRate" : {
1136
+ "nodetype" : "scalar",
1137
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1138
+ "oid" : "1.3.6.1.2.1.10.32.4.2",
1139
+ "status" : "current",
1140
+ "syntax" : {
1141
+ "type" : {
1142
+ "basetype" : "Integer32",
1143
+ "ranges" : [
1144
+ {
1145
+ "min" : "0",
1146
+ "max" : "3600000"
1147
+ },
1148
+ ],
1149
+ "range" : {
1150
+ "min" : "0",
1151
+ "max" : "3600000"
1152
+ },
1153
+ },
1154
+ },
1155
+ "access" : "readwrite",
1156
+ "default" : "0",
1157
+ "description" :
1158
+ """This variable indicates the number of milliseconds
1159
+ that must elapse between trap emissions. If events
1160
+ occur more rapidly, the impementation may simply fail
1161
+ to trap, or may queue traps until an appropriate time.""",
1162
+ }, # scalar
1163
+ "frConformance" : {
1164
+ "nodetype" : "node",
1165
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1166
+ "oid" : "1.3.6.1.2.1.10.32.6",
1167
+ }, # node
1168
+ "frGroups" : {
1169
+ "nodetype" : "node",
1170
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1171
+ "oid" : "1.3.6.1.2.1.10.32.6.1",
1172
+ }, # node
1173
+ "frCompliances" : {
1174
+ "nodetype" : "node",
1175
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1176
+ "oid" : "1.3.6.1.2.1.10.32.6.2",
1177
+ }, # node
1178
+ }, # nodes
1179
+
1180
+ "notifications" : {
1181
+ "frDLCIStatusChange" : {
1182
+ "nodetype" : "notification",
1183
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1184
+ "oid" : "1.3.6.1.2.1.10.32.0.1",
1185
+ "status" : "current",
1186
+ "objects" : {
1187
+ "frCircuitState" : {
1188
+ "nodetype" : "object",
1189
+ "module" : "FRAME-RELAY-DTE-MIB"
1190
+ },
1191
+ },
1192
+ "description" :
1193
+ """This trap indicates that the indicated Virtual Circuit
1194
+ has changed state. It has either been created or
1195
+ invalidated, or has toggled between the active and
1196
+ inactive states. If, however, the reason for the state
1197
+ change is due to the DLCMI going down, per-DLCI traps
1198
+ should not be generated.""",
1199
+ }, # notification
1200
+ }, # notifications
1201
+
1202
+ "groups" : {
1203
+ "frPortGroup" : {
1204
+ "nodetype" : "group",
1205
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1206
+ "oid" : "1.3.6.1.2.1.10.32.6.1.1",
1207
+ "status" : "current",
1208
+ "members" : {
1209
+ "frDlcmiIfIndex" : {
1210
+ "nodetype" : "member",
1211
+ "module" : "FRAME-RELAY-DTE-MIB"
1212
+ },
1213
+ "frDlcmiState" : {
1214
+ "nodetype" : "member",
1215
+ "module" : "FRAME-RELAY-DTE-MIB"
1216
+ },
1217
+ "frDlcmiAddress" : {
1218
+ "nodetype" : "member",
1219
+ "module" : "FRAME-RELAY-DTE-MIB"
1220
+ },
1221
+ "frDlcmiAddressLen" : {
1222
+ "nodetype" : "member",
1223
+ "module" : "FRAME-RELAY-DTE-MIB"
1224
+ },
1225
+ "frDlcmiPollingInterval" : {
1226
+ "nodetype" : "member",
1227
+ "module" : "FRAME-RELAY-DTE-MIB"
1228
+ },
1229
+ "frDlcmiFullEnquiryInterval" : {
1230
+ "nodetype" : "member",
1231
+ "module" : "FRAME-RELAY-DTE-MIB"
1232
+ },
1233
+ "frDlcmiErrorThreshold" : {
1234
+ "nodetype" : "member",
1235
+ "module" : "FRAME-RELAY-DTE-MIB"
1236
+ },
1237
+ "frDlcmiMonitoredEvents" : {
1238
+ "nodetype" : "member",
1239
+ "module" : "FRAME-RELAY-DTE-MIB"
1240
+ },
1241
+ "frDlcmiMaxSupportedVCs" : {
1242
+ "nodetype" : "member",
1243
+ "module" : "FRAME-RELAY-DTE-MIB"
1244
+ },
1245
+ "frDlcmiMulticast" : {
1246
+ "nodetype" : "member",
1247
+ "module" : "FRAME-RELAY-DTE-MIB"
1248
+ },
1249
+ "frDlcmiStatus" : {
1250
+ "nodetype" : "member",
1251
+ "module" : "FRAME-RELAY-DTE-MIB"
1252
+ },
1253
+ "frDlcmiRowStatus" : {
1254
+ "nodetype" : "member",
1255
+ "module" : "FRAME-RELAY-DTE-MIB"
1256
+ },
1257
+ }, # members
1258
+ "description" :
1259
+ """The objects necessary to control the Link Management
1260
+ Interface for a Frame Relay Interface as well as
1261
+ maintain the error statistics on this interface.""",
1262
+ }, # group
1263
+ "frCircuitGroup" : {
1264
+ "nodetype" : "group",
1265
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1266
+ "oid" : "1.3.6.1.2.1.10.32.6.1.2",
1267
+ "status" : "current",
1268
+ "members" : {
1269
+ "frCircuitIfIndex" : {
1270
+ "nodetype" : "member",
1271
+ "module" : "FRAME-RELAY-DTE-MIB"
1272
+ },
1273
+ "frCircuitDlci" : {
1274
+ "nodetype" : "member",
1275
+ "module" : "FRAME-RELAY-DTE-MIB"
1276
+ },
1277
+ "frCircuitState" : {
1278
+ "nodetype" : "member",
1279
+ "module" : "FRAME-RELAY-DTE-MIB"
1280
+ },
1281
+ "frCircuitReceivedFECNs" : {
1282
+ "nodetype" : "member",
1283
+ "module" : "FRAME-RELAY-DTE-MIB"
1284
+ },
1285
+ "frCircuitReceivedBECNs" : {
1286
+ "nodetype" : "member",
1287
+ "module" : "FRAME-RELAY-DTE-MIB"
1288
+ },
1289
+ "frCircuitSentFrames" : {
1290
+ "nodetype" : "member",
1291
+ "module" : "FRAME-RELAY-DTE-MIB"
1292
+ },
1293
+ "frCircuitSentOctets" : {
1294
+ "nodetype" : "member",
1295
+ "module" : "FRAME-RELAY-DTE-MIB"
1296
+ },
1297
+ "frCircuitReceivedFrames" : {
1298
+ "nodetype" : "member",
1299
+ "module" : "FRAME-RELAY-DTE-MIB"
1300
+ },
1301
+ "frCircuitReceivedOctets" : {
1302
+ "nodetype" : "member",
1303
+ "module" : "FRAME-RELAY-DTE-MIB"
1304
+ },
1305
+ "frCircuitCreationTime" : {
1306
+ "nodetype" : "member",
1307
+ "module" : "FRAME-RELAY-DTE-MIB"
1308
+ },
1309
+ "frCircuitLastTimeChange" : {
1310
+ "nodetype" : "member",
1311
+ "module" : "FRAME-RELAY-DTE-MIB"
1312
+ },
1313
+ "frCircuitCommittedBurst" : {
1314
+ "nodetype" : "member",
1315
+ "module" : "FRAME-RELAY-DTE-MIB"
1316
+ },
1317
+ "frCircuitExcessBurst" : {
1318
+ "nodetype" : "member",
1319
+ "module" : "FRAME-RELAY-DTE-MIB"
1320
+ },
1321
+ "frCircuitThroughput" : {
1322
+ "nodetype" : "member",
1323
+ "module" : "FRAME-RELAY-DTE-MIB"
1324
+ },
1325
+ "frCircuitMulticast" : {
1326
+ "nodetype" : "member",
1327
+ "module" : "FRAME-RELAY-DTE-MIB"
1328
+ },
1329
+ "frCircuitType" : {
1330
+ "nodetype" : "member",
1331
+ "module" : "FRAME-RELAY-DTE-MIB"
1332
+ },
1333
+ "frCircuitDiscards" : {
1334
+ "nodetype" : "member",
1335
+ "module" : "FRAME-RELAY-DTE-MIB"
1336
+ },
1337
+ "frCircuitReceivedDEs" : {
1338
+ "nodetype" : "member",
1339
+ "module" : "FRAME-RELAY-DTE-MIB"
1340
+ },
1341
+ "frCircuitSentDEs" : {
1342
+ "nodetype" : "member",
1343
+ "module" : "FRAME-RELAY-DTE-MIB"
1344
+ },
1345
+ "frCircuitLogicalIfIndex" : {
1346
+ "nodetype" : "member",
1347
+ "module" : "FRAME-RELAY-DTE-MIB"
1348
+ },
1349
+ "frCircuitRowStatus" : {
1350
+ "nodetype" : "member",
1351
+ "module" : "FRAME-RELAY-DTE-MIB"
1352
+ },
1353
+ }, # members
1354
+ "description" :
1355
+ """The objects necessary to control the Virtual Circuits
1356
+ layered onto a Frame Relay Interface.""",
1357
+ }, # group
1358
+ "frTrapGroup" : {
1359
+ "nodetype" : "group",
1360
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1361
+ "oid" : "1.3.6.1.2.1.10.32.6.1.3",
1362
+ "status" : "current",
1363
+ "members" : {
1364
+ "frTrapState" : {
1365
+ "nodetype" : "member",
1366
+ "module" : "FRAME-RELAY-DTE-MIB"
1367
+ },
1368
+ "frTrapMaxRate" : {
1369
+ "nodetype" : "member",
1370
+ "module" : "FRAME-RELAY-DTE-MIB"
1371
+ },
1372
+ }, # members
1373
+ "description" :
1374
+ """The objects necessary to control a Frame Relay
1375
+ Interface's notification messages.""",
1376
+ }, # group
1377
+ "frErrGroup" : {
1378
+ "nodetype" : "group",
1379
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1380
+ "oid" : "1.3.6.1.2.1.10.32.6.1.4",
1381
+ "status" : "current",
1382
+ "members" : {
1383
+ "frErrIfIndex" : {
1384
+ "nodetype" : "member",
1385
+ "module" : "FRAME-RELAY-DTE-MIB"
1386
+ },
1387
+ "frErrType" : {
1388
+ "nodetype" : "member",
1389
+ "module" : "FRAME-RELAY-DTE-MIB"
1390
+ },
1391
+ "frErrData" : {
1392
+ "nodetype" : "member",
1393
+ "module" : "FRAME-RELAY-DTE-MIB"
1394
+ },
1395
+ "frErrTime" : {
1396
+ "nodetype" : "member",
1397
+ "module" : "FRAME-RELAY-DTE-MIB"
1398
+ },
1399
+ "frErrFaults" : {
1400
+ "nodetype" : "member",
1401
+ "module" : "FRAME-RELAY-DTE-MIB"
1402
+ },
1403
+ "frErrFaultTime" : {
1404
+ "nodetype" : "member",
1405
+ "module" : "FRAME-RELAY-DTE-MIB"
1406
+ },
1407
+ }, # members
1408
+ "description" :
1409
+ """Objects designed to assist in debugging Frame Relay
1410
+ Interfaces.""",
1411
+ }, # group
1412
+ "frNotificationGroup" : {
1413
+ "nodetype" : "group",
1414
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1415
+ "oid" : "1.3.6.1.2.1.10.32.6.1.5",
1416
+ "status" : "current",
1417
+ "members" : {
1418
+ "frDLCIStatusChange" : {
1419
+ "nodetype" : "member",
1420
+ "module" : "FRAME-RELAY-DTE-MIB"
1421
+ },
1422
+ }, # members
1423
+ "description" :
1424
+ """Traps which may be used to enhance event driven
1425
+ management of the interface.""",
1426
+ }, # group
1427
+ "frPortGroup0" : {
1428
+ "nodetype" : "group",
1429
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1430
+ "oid" : "1.3.6.1.2.1.10.32.6.1.6",
1431
+ "status" : "current",
1432
+ "members" : {
1433
+ "frDlcmiIfIndex" : {
1434
+ "nodetype" : "member",
1435
+ "module" : "FRAME-RELAY-DTE-MIB"
1436
+ },
1437
+ "frDlcmiState" : {
1438
+ "nodetype" : "member",
1439
+ "module" : "FRAME-RELAY-DTE-MIB"
1440
+ },
1441
+ "frDlcmiAddress" : {
1442
+ "nodetype" : "member",
1443
+ "module" : "FRAME-RELAY-DTE-MIB"
1444
+ },
1445
+ "frDlcmiAddressLen" : {
1446
+ "nodetype" : "member",
1447
+ "module" : "FRAME-RELAY-DTE-MIB"
1448
+ },
1449
+ "frDlcmiPollingInterval" : {
1450
+ "nodetype" : "member",
1451
+ "module" : "FRAME-RELAY-DTE-MIB"
1452
+ },
1453
+ "frDlcmiFullEnquiryInterval" : {
1454
+ "nodetype" : "member",
1455
+ "module" : "FRAME-RELAY-DTE-MIB"
1456
+ },
1457
+ "frDlcmiErrorThreshold" : {
1458
+ "nodetype" : "member",
1459
+ "module" : "FRAME-RELAY-DTE-MIB"
1460
+ },
1461
+ "frDlcmiMonitoredEvents" : {
1462
+ "nodetype" : "member",
1463
+ "module" : "FRAME-RELAY-DTE-MIB"
1464
+ },
1465
+ "frDlcmiMaxSupportedVCs" : {
1466
+ "nodetype" : "member",
1467
+ "module" : "FRAME-RELAY-DTE-MIB"
1468
+ },
1469
+ "frDlcmiMulticast" : {
1470
+ "nodetype" : "member",
1471
+ "module" : "FRAME-RELAY-DTE-MIB"
1472
+ },
1473
+ }, # members
1474
+ "description" :
1475
+ """The objects necessary to control the Link Management
1476
+ Interface for a Frame Relay Interface as well as
1477
+ maintain the error statistics on this interface from
1478
+ RFC 1315.""",
1479
+ }, # group
1480
+ "frCircuitGroup0" : {
1481
+ "nodetype" : "group",
1482
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1483
+ "oid" : "1.3.6.1.2.1.10.32.6.1.7",
1484
+ "status" : "current",
1485
+ "members" : {
1486
+ "frCircuitIfIndex" : {
1487
+ "nodetype" : "member",
1488
+ "module" : "FRAME-RELAY-DTE-MIB"
1489
+ },
1490
+ "frCircuitDlci" : {
1491
+ "nodetype" : "member",
1492
+ "module" : "FRAME-RELAY-DTE-MIB"
1493
+ },
1494
+ "frCircuitState" : {
1495
+ "nodetype" : "member",
1496
+ "module" : "FRAME-RELAY-DTE-MIB"
1497
+ },
1498
+ "frCircuitReceivedFECNs" : {
1499
+ "nodetype" : "member",
1500
+ "module" : "FRAME-RELAY-DTE-MIB"
1501
+ },
1502
+ "frCircuitReceivedBECNs" : {
1503
+ "nodetype" : "member",
1504
+ "module" : "FRAME-RELAY-DTE-MIB"
1505
+ },
1506
+ "frCircuitSentFrames" : {
1507
+ "nodetype" : "member",
1508
+ "module" : "FRAME-RELAY-DTE-MIB"
1509
+ },
1510
+ "frCircuitSentOctets" : {
1511
+ "nodetype" : "member",
1512
+ "module" : "FRAME-RELAY-DTE-MIB"
1513
+ },
1514
+ "frCircuitReceivedFrames" : {
1515
+ "nodetype" : "member",
1516
+ "module" : "FRAME-RELAY-DTE-MIB"
1517
+ },
1518
+ "frCircuitReceivedOctets" : {
1519
+ "nodetype" : "member",
1520
+ "module" : "FRAME-RELAY-DTE-MIB"
1521
+ },
1522
+ "frCircuitCreationTime" : {
1523
+ "nodetype" : "member",
1524
+ "module" : "FRAME-RELAY-DTE-MIB"
1525
+ },
1526
+ "frCircuitLastTimeChange" : {
1527
+ "nodetype" : "member",
1528
+ "module" : "FRAME-RELAY-DTE-MIB"
1529
+ },
1530
+ "frCircuitCommittedBurst" : {
1531
+ "nodetype" : "member",
1532
+ "module" : "FRAME-RELAY-DTE-MIB"
1533
+ },
1534
+ "frCircuitExcessBurst" : {
1535
+ "nodetype" : "member",
1536
+ "module" : "FRAME-RELAY-DTE-MIB"
1537
+ },
1538
+ "frCircuitThroughput" : {
1539
+ "nodetype" : "member",
1540
+ "module" : "FRAME-RELAY-DTE-MIB"
1541
+ },
1542
+ }, # members
1543
+ "description" :
1544
+ """The objects necessary to control the Virtual Circuits
1545
+ layered onto a Frame Relay Interface from RFC 1315.""",
1546
+ }, # group
1547
+ "frErrGroup0" : {
1548
+ "nodetype" : "group",
1549
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1550
+ "oid" : "1.3.6.1.2.1.10.32.6.1.8",
1551
+ "status" : "current",
1552
+ "members" : {
1553
+ "frErrIfIndex" : {
1554
+ "nodetype" : "member",
1555
+ "module" : "FRAME-RELAY-DTE-MIB"
1556
+ },
1557
+ "frErrType" : {
1558
+ "nodetype" : "member",
1559
+ "module" : "FRAME-RELAY-DTE-MIB"
1560
+ },
1561
+ "frErrData" : {
1562
+ "nodetype" : "member",
1563
+ "module" : "FRAME-RELAY-DTE-MIB"
1564
+ },
1565
+ "frErrTime" : {
1566
+ "nodetype" : "member",
1567
+ "module" : "FRAME-RELAY-DTE-MIB"
1568
+ },
1569
+ }, # members
1570
+ "description" :
1571
+ """Objects designed to assist in debugging Frame Relay
1572
+ Interfaces from RFC 1315.""",
1573
+ }, # group
1574
+ "frTrapGroup0" : {
1575
+ "nodetype" : "group",
1576
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1577
+ "oid" : "1.3.6.1.2.1.10.32.6.1.9",
1578
+ "status" : "current",
1579
+ "members" : {
1580
+ "frTrapState" : {
1581
+ "nodetype" : "member",
1582
+ "module" : "FRAME-RELAY-DTE-MIB"
1583
+ },
1584
+ }, # members
1585
+ "description" :
1586
+ """The objects necessary to control a Frame Relay
1587
+ Interface's notification messages from RFC 1315.""",
1588
+ }, # group
1589
+ }, # groups
1590
+
1591
+ "compliances" : {
1592
+ "frCompliance" : {
1593
+ "nodetype" : "compliance",
1594
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1595
+ "oid" : "1.3.6.1.2.1.10.32.6.2.1",
1596
+ "status" : "current",
1597
+ "description" :
1598
+ """The compliance statement """,
1599
+ "requires" : {
1600
+ "frPortGroup" : {
1601
+ "nodetype" : "mandatory",
1602
+ "module" : "FRAME-RELAY-DTE-MIB"
1603
+ },
1604
+ "frCircuitGroup" : {
1605
+ "nodetype" : "mandatory",
1606
+ "module" : "FRAME-RELAY-DTE-MIB"
1607
+ },
1608
+ "frErrGroup" : {
1609
+ "nodetype" : "optional",
1610
+ "module" : "FRAME-RELAY-DTE-MIB",
1611
+ "description" :
1612
+ """This optional group is used for debugging Frame Relay
1613
+ Systems.""",
1614
+ },
1615
+ "frTrapGroup" : {
1616
+ "nodetype" : "optional",
1617
+ "module" : "FRAME-RELAY-DTE-MIB",
1618
+ "description" :
1619
+ """This optional group is used for the management of
1620
+ asynchronous notifications by Frame Relay Systems.""",
1621
+ },
1622
+ "frNotificationGroup" : {
1623
+ "nodetype" : "optional",
1624
+ "module" : "FRAME-RELAY-DTE-MIB",
1625
+ "description" :
1626
+ """This optional group defines the asynchronous
1627
+ notifications generated by Frame Relay Systems.""",
1628
+ },
1629
+ }, # requires
1630
+ "refinements" : {
1631
+ "frDlcmiRowStatus" : {
1632
+ "module" : "FRAME-RELAY-DTE-MIB",
1633
+ "access" : "readonly",
1634
+ "description" :
1635
+ """Row creation is not required for the frDlcmiTable.""",
1636
+ },
1637
+ "frCircuitRowStatus" : {
1638
+ "module" : "FRAME-RELAY-DTE-MIB",
1639
+ "access" : "readonly",
1640
+ "description" :
1641
+ """Row creation is not required for the frCircuitTable.""",
1642
+ },
1643
+ }, # refinements
1644
+
1645
+ }, # compliance
1646
+ "frCompliance0" : {
1647
+ "nodetype" : "compliance",
1648
+ "moduleName" : "FRAME-RELAY-DTE-MIB",
1649
+ "oid" : "1.3.6.1.2.1.10.32.6.2.2",
1650
+ "status" : "current",
1651
+ "description" :
1652
+ """The compliance statement for objects and the trap
1653
+ defined in RFC 1315.""",
1654
+ "requires" : {
1655
+ "frPortGroup0" : {
1656
+ "nodetype" : "mandatory",
1657
+ "module" : "FRAME-RELAY-DTE-MIB"
1658
+ },
1659
+ "frCircuitGroup0" : {
1660
+ "nodetype" : "mandatory",
1661
+ "module" : "FRAME-RELAY-DTE-MIB"
1662
+ },
1663
+ "frErrGroup0" : {
1664
+ "nodetype" : "optional",
1665
+ "module" : "FRAME-RELAY-DTE-MIB",
1666
+ "description" :
1667
+ """This optional group is used for debugging Frame Relay
1668
+ Systems.""",
1669
+ },
1670
+ "frTrapGroup0" : {
1671
+ "nodetype" : "optional",
1672
+ "module" : "FRAME-RELAY-DTE-MIB",
1673
+ "description" :
1674
+ """This optional group is used for the management of
1675
+ asynchronous notifications by Frame Relay Systems.""",
1676
+ },
1677
+ "frNotificationGroup" : {
1678
+ "nodetype" : "optional",
1679
+ "module" : "FRAME-RELAY-DTE-MIB",
1680
+ "description" :
1681
+ """This optional group defines the asynchronous
1682
+ notifications generated by Frame Relay Systems.""",
1683
+ },
1684
+ }, # requires
1685
+ }, # compliance
1686
+ }, # compliances
1687
+
1688
+ }