logstash-integration-snmp 4.0.0-java

Sign up to get free protection for your applications and to get access to all the features.
Files changed (324) hide show
  1. checksums.yaml +7 -0
  2. data/CHANGELOG.md +23 -0
  3. data/CONTRIBUTORS +20 -0
  4. data/Gemfile +11 -0
  5. data/LICENSE +202 -0
  6. data/README.md +89 -0
  7. data/VERSION +1 -0
  8. data/docs/index.asciidoc +202 -0
  9. data/docs/input-snmp.asciidoc +524 -0
  10. data/docs/input-snmptrap.asciidoc +392 -0
  11. data/lib/logstash/inputs/snmp.rb +369 -0
  12. data/lib/logstash/inputs/snmptrap.rb +190 -0
  13. data/lib/logstash/plugin_mixins/snmp/common.rb +197 -0
  14. data/lib/logstash-integration-snmp_jars.rb +6 -0
  15. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  16. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  17. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  18. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  19. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  20. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  21. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  22. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  23. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  24. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  25. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  26. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  27. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  28. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  29. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  30. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  31. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  32. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  33. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  34. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  35. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  36. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  37. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  38. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  39. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  40. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  41. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  42. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  43. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  44. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  45. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  46. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  47. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  48. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  49. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  50. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  51. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  52. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  53. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  54. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  55. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  56. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  57. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  58. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  59. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  60. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  61. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  62. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  63. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  64. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  65. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  66. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  67. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  68. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  69. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  70. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  71. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  72. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  73. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  74. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  75. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  76. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  77. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  78. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  79. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  80. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  81. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  82. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  83. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  84. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  85. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  86. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  87. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  88. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  89. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  90. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  91. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  92. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  93. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  94. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  95. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  96. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  97. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  98. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  99. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  100. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  101. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  102. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  103. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  104. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  105. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  106. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  107. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  108. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  109. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  110. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  111. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  112. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  113. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  114. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  115. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  116. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  117. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  118. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  119. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  120. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  121. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  122. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  123. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  124. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  125. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  126. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  127. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  128. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  129. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  130. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  131. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  132. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  133. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  134. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  135. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  136. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  137. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  138. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  139. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  140. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  141. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  142. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  143. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  144. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  145. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  146. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  147. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  148. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  149. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  150. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  151. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  152. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  153. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  154. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  155. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  156. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  157. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  158. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  159. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  160. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  161. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  162. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  163. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  164. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  165. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  166. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  167. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  168. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  169. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  170. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  171. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  172. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  173. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  174. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  175. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  176. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  177. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  178. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  179. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  180. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  181. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  182. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  183. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  184. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  185. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  186. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  187. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  188. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  189. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  190. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  191. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  192. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  193. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  194. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  195. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  196. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  197. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  198. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  199. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  200. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  201. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  202. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  203. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  204. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  205. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  206. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  207. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  208. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  209. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  210. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  211. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  212. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  213. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  214. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  215. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  216. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  217. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  218. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  219. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  220. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  221. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  222. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  223. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  224. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  225. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  226. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  227. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  228. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  229. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  230. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  231. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  232. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  233. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  234. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  235. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  236. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  237. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  238. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  239. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  240. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  241. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  242. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  243. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  244. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  245. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  246. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  247. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  248. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  249. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  250. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  251. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  252. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  253. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  254. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  255. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  256. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  257. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  258. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  259. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  260. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  261. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  262. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  263. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  264. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  265. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  266. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  267. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  268. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  269. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  270. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  271. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  272. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  273. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  274. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  275. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  276. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  277. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  278. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  279. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  280. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  281. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  282. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  283. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  284. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  285. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  286. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  287. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  288. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  289. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  290. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  291. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  292. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  293. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  294. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  295. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  296. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  297. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  298. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  299. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  300. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  301. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  302. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  303. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  304. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  305. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  306. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  307. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  308. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  309. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  310. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  311. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  312. data/lib/mibs/logstash/iso.dic +18 -0
  313. data/logstash-integration-snmp.gemspec +40 -0
  314. data/spec/fixtures/RFC1213-MIB.dic +3445 -0
  315. data/spec/fixtures/collision.dic +25 -0
  316. data/spec/integration/inputs/snmp_spec.rb +443 -0
  317. data/spec/integration/inputs/snmptrap_spec.rb +383 -0
  318. data/spec/unit/inputs/common_spec.rb +264 -0
  319. data/spec/unit/inputs/snmp_spec.rb +510 -0
  320. data/spec/unit/inputs/snmptrap_spec.rb +141 -0
  321. data/vendor/jar-dependencies/org/logstash/integrations/plugin/4.0.0/plugin-4.0.0.jar +0 -0
  322. data/vendor/jar-dependencies/org/snakeyaml/snakeyaml-engine/2.7/snakeyaml-engine-2.7.jar +0 -0
  323. data/vendor/jar-dependencies/org/snmp4j/snmp4j/3.8.0/snmp4j-3.8.0.jar +0 -0
  324. metadata +523 -0
@@ -0,0 +1,3151 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python DISMAN-EVENT-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/DISMAN-EVENT-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "DISMAN-EVENT-MIB",
11
+
12
+ "DISMAN-EVENT-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF Distributed Management Working Group""",
17
+ "contact" :
18
+ """Ramanathan Kavasseri
19
+ Cisco Systems, Inc.
20
+ 170 West Tasman Drive,
21
+ San Jose CA 95134-1706.
22
+ Phone: +1 408 526 4527
23
+ Email: ramk@cisco.com""",
24
+ "description" :
25
+ """The MIB module for defining event triggers and actions
26
+ for network management purposes.""",
27
+ "revisions" : (
28
+ {
29
+ "date" : "2000-10-16 00:00",
30
+ "description" :
31
+ """This is the initial version of this MIB.
32
+ Published as RFC 2981""",
33
+ },
34
+ ),
35
+ "identity node" : "dismanEventMIB",
36
+ },
37
+
38
+ "imports" : (
39
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
40
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
41
+ {"module" : "SNMPv2-SMI", "name" : "Integer32"},
42
+ {"module" : "SNMPv2-SMI", "name" : "Unsigned32"},
43
+ {"module" : "SNMPv2-SMI", "name" : "NOTIFICATION-TYPE"},
44
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
45
+ {"module" : "SNMPv2-SMI", "name" : "Gauge32"},
46
+ {"module" : "SNMPv2-SMI", "name" : "mib-2"},
47
+ {"module" : "SNMPv2-SMI", "name" : "zeroDotZero"},
48
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
49
+ {"module" : "SNMPv2-TC", "name" : "RowStatus"},
50
+ {"module" : "SNMPv2-TC", "name" : "TruthValue"},
51
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
52
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
53
+ {"module" : "SNMPv2-CONF", "name" : "NOTIFICATION-GROUP"},
54
+ {"module" : "SNMPv2-MIB", "name" : "sysUpTime"},
55
+ {"module" : "SNMP-TARGET-MIB", "name" : "SnmpTagValue"},
56
+ {"module" : "SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
57
+ ),
58
+
59
+ "typedefs" : {
60
+ "FailureReason" : {
61
+ "basetype" : "Enumeration",
62
+ "status" : "current",
63
+ "sampleOverrun" : {
64
+ "nodetype" : "namednumber",
65
+ "number" : "-6"
66
+ },
67
+ "badType" : {
68
+ "nodetype" : "namednumber",
69
+ "number" : "-5"
70
+ },
71
+ "noResponse" : {
72
+ "nodetype" : "namednumber",
73
+ "number" : "-4"
74
+ },
75
+ "destinationUnreachable" : {
76
+ "nodetype" : "namednumber",
77
+ "number" : "-3"
78
+ },
79
+ "badDestination" : {
80
+ "nodetype" : "namednumber",
81
+ "number" : "-2"
82
+ },
83
+ "localResourceLack" : {
84
+ "nodetype" : "namednumber",
85
+ "number" : "-1"
86
+ },
87
+ "noError" : {
88
+ "nodetype" : "namednumber",
89
+ "number" : "0"
90
+ },
91
+ "tooBig" : {
92
+ "nodetype" : "namednumber",
93
+ "number" : "1"
94
+ },
95
+ "noSuchName" : {
96
+ "nodetype" : "namednumber",
97
+ "number" : "2"
98
+ },
99
+ "badValue" : {
100
+ "nodetype" : "namednumber",
101
+ "number" : "3"
102
+ },
103
+ "readOnly" : {
104
+ "nodetype" : "namednumber",
105
+ "number" : "4"
106
+ },
107
+ "genErr" : {
108
+ "nodetype" : "namednumber",
109
+ "number" : "5"
110
+ },
111
+ "noAccess" : {
112
+ "nodetype" : "namednumber",
113
+ "number" : "6"
114
+ },
115
+ "wrongType" : {
116
+ "nodetype" : "namednumber",
117
+ "number" : "7"
118
+ },
119
+ "wrongLength" : {
120
+ "nodetype" : "namednumber",
121
+ "number" : "8"
122
+ },
123
+ "wrongEncoding" : {
124
+ "nodetype" : "namednumber",
125
+ "number" : "9"
126
+ },
127
+ "wrongValue" : {
128
+ "nodetype" : "namednumber",
129
+ "number" : "10"
130
+ },
131
+ "noCreation" : {
132
+ "nodetype" : "namednumber",
133
+ "number" : "11"
134
+ },
135
+ "inconsistentValue" : {
136
+ "nodetype" : "namednumber",
137
+ "number" : "12"
138
+ },
139
+ "resourceUnavailable" : {
140
+ "nodetype" : "namednumber",
141
+ "number" : "13"
142
+ },
143
+ "commitFailed" : {
144
+ "nodetype" : "namednumber",
145
+ "number" : "14"
146
+ },
147
+ "undoFailed" : {
148
+ "nodetype" : "namednumber",
149
+ "number" : "15"
150
+ },
151
+ "authorizationError" : {
152
+ "nodetype" : "namednumber",
153
+ "number" : "16"
154
+ },
155
+ "notWritable" : {
156
+ "nodetype" : "namednumber",
157
+ "number" : "17"
158
+ },
159
+ "inconsistentName" : {
160
+ "nodetype" : "namednumber",
161
+ "number" : "18"
162
+ },
163
+ "description" :
164
+ """Reasons for failures in an attempt to perform a management
165
+ request.
166
+
167
+ The first group of errors, numbered less than 0, are related
168
+ to problems in sending the request. The existence of a
169
+ particular error code here does not imply that all
170
+ implementations are capable of sensing that error and
171
+
172
+
173
+ returning that code.
174
+
175
+ The second group, numbered greater than 0, are copied
176
+ directly from SNMP protocol operations and are intended to
177
+ carry exactly the meanings defined for the protocol as returned
178
+ in an SNMP response.
179
+
180
+ localResourceLack some local resource such as memory
181
+ lacking or
182
+ mteResourceSampleInstanceMaximum
183
+ exceeded
184
+ badDestination unrecognized domain name or otherwise
185
+ invalid destination address
186
+ destinationUnreachable can't get to destination address
187
+ noResponse no response to SNMP request
188
+ badType the data syntax of a retrieved object
189
+ as not as expected
190
+ sampleOverrun another sample attempt occurred before
191
+ the previous one completed""",
192
+ },
193
+ }, # typedefs
194
+
195
+ "nodes" : {
196
+ "sysUpTimeInstance" : {
197
+ "nodetype" : "node",
198
+ "moduleName" : "DISMAN-EVENT-MIB",
199
+ "oid" : "1.3.6.1.2.1.1.3.0",
200
+ }, # node
201
+ "dismanEventMIB" : {
202
+ "nodetype" : "node",
203
+ "moduleName" : "DISMAN-EVENT-MIB",
204
+ "oid" : "1.3.6.1.2.1.88",
205
+ "status" : "current",
206
+ }, # node
207
+ "dismanEventMIBObjects" : {
208
+ "nodetype" : "node",
209
+ "moduleName" : "DISMAN-EVENT-MIB",
210
+ "oid" : "1.3.6.1.2.1.88.1",
211
+ }, # node
212
+ "mteResource" : {
213
+ "nodetype" : "node",
214
+ "moduleName" : "DISMAN-EVENT-MIB",
215
+ "oid" : "1.3.6.1.2.1.88.1.1",
216
+ }, # node
217
+ "mteResourceSampleMinimum" : {
218
+ "nodetype" : "scalar",
219
+ "moduleName" : "DISMAN-EVENT-MIB",
220
+ "oid" : "1.3.6.1.2.1.88.1.1.1",
221
+ "status" : "current",
222
+ "syntax" : {
223
+ "type" : {
224
+ "basetype" : "Integer32",
225
+ "ranges" : [
226
+ {
227
+ "min" : "1",
228
+ "max" : "2147483647"
229
+ },
230
+ ],
231
+ "range" : {
232
+ "min" : "1",
233
+ "max" : "2147483647"
234
+ },
235
+ },
236
+ },
237
+ "access" : "readwrite",
238
+ "units" : "seconds",
239
+ "description" :
240
+ """The minimum mteTriggerFrequency this system will
241
+ accept. A system may use the larger values of this minimum to
242
+ lessen the impact of constant sampling. For larger
243
+ sampling intervals the system samples less often and
244
+ suffers less overhead. This object provides a way to enforce
245
+ such lower overhead for all triggers created after it is
246
+ set.
247
+
248
+ Unless explicitly resource limited, a system's value for
249
+ this object SHOULD be 1, allowing as small as a 1 second
250
+ interval for ongoing trigger sampling.
251
+
252
+ Changing this value will not invalidate an existing setting
253
+ of mteTriggerFrequency.""",
254
+ }, # scalar
255
+ "mteResourceSampleInstanceMaximum" : {
256
+ "nodetype" : "scalar",
257
+ "moduleName" : "DISMAN-EVENT-MIB",
258
+ "oid" : "1.3.6.1.2.1.88.1.1.2",
259
+ "status" : "current",
260
+ "syntax" : {
261
+ "type" : { "module" :"", "name" : "Unsigned32"},
262
+ },
263
+ "access" : "readwrite",
264
+ "units" : "instances",
265
+ "description" :
266
+ """The maximum number of instance entries this system will
267
+ support for sampling.
268
+
269
+ These are the entries that maintain state, one for each
270
+ instance of each sampled object as selected by
271
+ mteTriggerValueID. Note that wildcarded objects result
272
+ in multiple instances of this state.
273
+
274
+ A value of 0 indicates no preset limit, that is, the limit
275
+ is dynamic based on system operation and resources.
276
+
277
+ Unless explicitly resource limited, a system's value for
278
+ this object SHOULD be 0.
279
+
280
+ Changing this value will not eliminate or inhibit existing
281
+ sample state but could prevent allocation of additional state
282
+ information.""",
283
+ }, # scalar
284
+ "mteResourceSampleInstances" : {
285
+ "nodetype" : "scalar",
286
+ "moduleName" : "DISMAN-EVENT-MIB",
287
+ "oid" : "1.3.6.1.2.1.88.1.1.3",
288
+ "status" : "current",
289
+ "syntax" : {
290
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
291
+ },
292
+ "access" : "readonly",
293
+ "units" : "instances",
294
+ "description" :
295
+ """The number of currently active instance entries as
296
+ defined for mteResourceSampleInstanceMaximum.""",
297
+ }, # scalar
298
+ "mteResourceSampleInstancesHigh" : {
299
+ "nodetype" : "scalar",
300
+ "moduleName" : "DISMAN-EVENT-MIB",
301
+ "oid" : "1.3.6.1.2.1.88.1.1.4",
302
+ "status" : "current",
303
+ "syntax" : {
304
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
305
+ },
306
+ "access" : "readonly",
307
+ "units" : "instances",
308
+ "description" :
309
+ """The highest value of mteResourceSampleInstances that has
310
+ occurred since initialization of the management system.""",
311
+ }, # scalar
312
+ "mteResourceSampleInstanceLacks" : {
313
+ "nodetype" : "scalar",
314
+ "moduleName" : "DISMAN-EVENT-MIB",
315
+ "oid" : "1.3.6.1.2.1.88.1.1.5",
316
+ "status" : "current",
317
+ "syntax" : {
318
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
319
+ },
320
+ "access" : "readonly",
321
+ "units" : "instances",
322
+ "description" :
323
+ """The number of times this system could not take a new sample
324
+ because that allocation would have exceeded the limit set by
325
+ mteResourceSampleInstanceMaximum.""",
326
+ }, # scalar
327
+ "mteTrigger" : {
328
+ "nodetype" : "node",
329
+ "moduleName" : "DISMAN-EVENT-MIB",
330
+ "oid" : "1.3.6.1.2.1.88.1.2",
331
+ }, # node
332
+ "mteTriggerFailures" : {
333
+ "nodetype" : "scalar",
334
+ "moduleName" : "DISMAN-EVENT-MIB",
335
+ "oid" : "1.3.6.1.2.1.88.1.2.1",
336
+ "status" : "current",
337
+ "syntax" : {
338
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
339
+ },
340
+ "access" : "readonly",
341
+ "units" : "failures",
342
+ "description" :
343
+ """The number of times an attempt to check for a trigger
344
+ condition has failed. This counts individually for each
345
+ attempt in a group of targets or each attempt for a
346
+
347
+
348
+ wildcarded object.""",
349
+ }, # scalar
350
+ "mteTriggerTable" : {
351
+ "nodetype" : "table",
352
+ "moduleName" : "DISMAN-EVENT-MIB",
353
+ "oid" : "1.3.6.1.2.1.88.1.2.2",
354
+ "status" : "current",
355
+ "description" :
356
+ """A table of management event trigger information.""",
357
+ }, # table
358
+ "mteTriggerEntry" : {
359
+ "nodetype" : "row",
360
+ "moduleName" : "DISMAN-EVENT-MIB",
361
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1",
362
+ "create" : "true",
363
+ "status" : "current",
364
+ "implied" : "true",
365
+ "linkage" : [
366
+ "mteOwner",
367
+ "mteTriggerName",
368
+ ],
369
+ "description" :
370
+ """Information about a single trigger. Applications create and
371
+ delete entries using mteTriggerEntryStatus.""",
372
+ }, # row
373
+ "mteOwner" : {
374
+ "nodetype" : "column",
375
+ "moduleName" : "DISMAN-EVENT-MIB",
376
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.1",
377
+ "status" : "current",
378
+ "syntax" : {
379
+ "type" : {
380
+ "basetype" : "OctetString",
381
+ "parent module" : {
382
+ "name" : "SNMP-FRAMEWORK-MIB",
383
+ "type" : "SnmpAdminString",
384
+ },
385
+ "ranges" : [
386
+ {
387
+ "min" : "0",
388
+ "max" : "32"
389
+ },
390
+ ],
391
+ "range" : {
392
+ "min" : "0",
393
+ "max" : "32"
394
+ },
395
+ },
396
+ },
397
+ "access" : "noaccess",
398
+ "description" :
399
+ """The owner of this entry. The exact semantics of this
400
+ string are subject to the security policy defined by the
401
+ security administrator.""",
402
+ }, # column
403
+ "mteTriggerName" : {
404
+ "nodetype" : "column",
405
+ "moduleName" : "DISMAN-EVENT-MIB",
406
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.2",
407
+ "status" : "current",
408
+ "syntax" : {
409
+ "type" : {
410
+ "basetype" : "OctetString",
411
+ "parent module" : {
412
+ "name" : "SNMP-FRAMEWORK-MIB",
413
+ "type" : "SnmpAdminString",
414
+ },
415
+ "ranges" : [
416
+ {
417
+ "min" : "1",
418
+ "max" : "32"
419
+ },
420
+ ],
421
+ "range" : {
422
+ "min" : "1",
423
+ "max" : "32"
424
+ },
425
+ },
426
+ },
427
+ "access" : "noaccess",
428
+ "description" :
429
+ """A locally-unique, administratively assigned name for the
430
+ trigger within the scope of mteOwner.""",
431
+ }, # column
432
+ "mteTriggerComment" : {
433
+ "nodetype" : "column",
434
+ "moduleName" : "DISMAN-EVENT-MIB",
435
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.3",
436
+ "status" : "current",
437
+ "syntax" : {
438
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
439
+ },
440
+ "access" : "readwrite",
441
+ "default" : "",
442
+ "description" :
443
+ """A description of the trigger's function and use.""",
444
+ }, # column
445
+ "mteTriggerTest" : {
446
+ "nodetype" : "column",
447
+ "moduleName" : "DISMAN-EVENT-MIB",
448
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.4",
449
+ "status" : "current",
450
+ "syntax" : {
451
+ "type" : {
452
+ "basetype" : "Bits",
453
+ "existence" : {
454
+ "nodetype" : "namednumber",
455
+ "number" : "0"
456
+ },
457
+ "boolean" : {
458
+ "nodetype" : "namednumber",
459
+ "number" : "1"
460
+ },
461
+ "threshold" : {
462
+ "nodetype" : "namednumber",
463
+ "number" : "2"
464
+ },
465
+ },
466
+ },
467
+ "access" : "readwrite",
468
+ "default" : "(boolean)",
469
+ "description" :
470
+ """The type of trigger test to perform. For 'boolean' and
471
+ 'threshold' tests, the object at mteTriggerValueID MUST
472
+ evaluate to an integer, that is, anything that ends up encoded
473
+ for transmission (that is, in BER, not ASN.1) as an integer.
474
+
475
+ For 'existence', the specific test is as selected by
476
+ mteTriggerExistenceTest. When an object appears, vanishes
477
+ or changes value, the trigger fires. If the object's
478
+ appearance caused the trigger firing, the object MUST
479
+ vanish before the trigger can be fired again for it, and
480
+ vice versa. If the trigger fired due to a change in the
481
+ object's value, it will be fired again on every successive
482
+ value change for that object.
483
+
484
+ For 'boolean', the specific test is as selected by
485
+ mteTriggerBooleanTest. If the test result is true the trigger
486
+ fires. The trigger will not fire again until the value has
487
+ become false and come back to true.
488
+
489
+ For 'threshold' the test works as described below for
490
+
491
+
492
+ mteTriggerThresholdStartup, mteTriggerThresholdRising, and
493
+ mteTriggerThresholdFalling.
494
+
495
+ Note that combining 'boolean' and 'threshold' tests on the
496
+ same object may be somewhat redundant.""",
497
+ }, # column
498
+ "mteTriggerSampleType" : {
499
+ "nodetype" : "column",
500
+ "moduleName" : "DISMAN-EVENT-MIB",
501
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.5",
502
+ "status" : "current",
503
+ "syntax" : {
504
+ "type" : {
505
+ "basetype" : "Enumeration",
506
+ "absoluteValue" : {
507
+ "nodetype" : "namednumber",
508
+ "number" : "1"
509
+ },
510
+ "deltaValue" : {
511
+ "nodetype" : "namednumber",
512
+ "number" : "2"
513
+ },
514
+ },
515
+ },
516
+ "access" : "readwrite",
517
+ "default" : "absoluteValue",
518
+ "description" :
519
+ """The type of sampling to perform.
520
+
521
+ An 'absoluteValue' sample requires only a single sample to be
522
+ meaningful, and is exactly the value of the object at
523
+ mteTriggerValueID at the sample time.
524
+
525
+ A 'deltaValue' requires two samples to be meaningful and is
526
+ thus not available for testing until the second and subsequent
527
+ samples after the object at mteTriggerValueID is first found
528
+ to exist. It is the difference between the two samples. For
529
+ unsigned values it is always positive, based on unsigned
530
+ arithmetic. For signed values it can be positive or negative.
531
+
532
+ For SNMP counters to be meaningful they should be sampled as a
533
+ 'deltaValue'.
534
+
535
+ For 'deltaValue' mteTriggerDeltaTable contains further
536
+ parameters.
537
+
538
+ If only 'existence' is set in mteTriggerTest this object has
539
+ no meaning.""",
540
+ }, # column
541
+ "mteTriggerValueID" : {
542
+ "nodetype" : "column",
543
+ "moduleName" : "DISMAN-EVENT-MIB",
544
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.6",
545
+ "status" : "current",
546
+ "syntax" : {
547
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
548
+ },
549
+ "access" : "readwrite",
550
+ "default" : "0.0",
551
+ "description" :
552
+ """The object identifier of the MIB object to sample to see
553
+ if the trigger should fire.
554
+
555
+ This may be wildcarded by truncating all or part of the
556
+ instance portion, in which case the value is obtained
557
+ as if with a GetNext function, checking multiple values
558
+
559
+
560
+ if they exist. If such wildcarding is applied,
561
+ mteTriggerValueIDWildcard must be 'true' and if not it must
562
+ be 'false'.
563
+
564
+ Bad object identifiers or a mismatch between truncating the
565
+ identifier and the value of mteTriggerValueIDWildcard result
566
+ in operation as one would expect when providing the wrong
567
+ identifier to a Get or GetNext operation. The Get will fail
568
+ or get the wrong object. The GetNext will indeed get whatever
569
+ is next, proceeding until it runs past the initial part of the
570
+ identifier and perhaps many unintended objects for confusing
571
+ results. If the value syntax of those objects is not usable,
572
+ that results in a 'badType' error that terminates the scan.
573
+
574
+ Each instance that fills the wildcard is independent of any
575
+ additional instances, that is, wildcarded objects operate
576
+ as if there were a separate table entry for each instance
577
+ that fills the wildcard without having to actually predict
578
+ all possible instances ahead of time.""",
579
+ }, # column
580
+ "mteTriggerValueIDWildcard" : {
581
+ "nodetype" : "column",
582
+ "moduleName" : "DISMAN-EVENT-MIB",
583
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.7",
584
+ "status" : "current",
585
+ "syntax" : {
586
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
587
+ },
588
+ "access" : "readwrite",
589
+ "default" : "false",
590
+ "description" :
591
+ """Control for whether mteTriggerValueID is to be treated as
592
+ fully-specified or wildcarded, with 'true' indicating wildcard.""",
593
+ }, # column
594
+ "mteTriggerTargetTag" : {
595
+ "nodetype" : "column",
596
+ "moduleName" : "DISMAN-EVENT-MIB",
597
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.8",
598
+ "status" : "current",
599
+ "syntax" : {
600
+ "type" : { "module" :"SNMP-TARGET-MIB", "name" : "SnmpTagValue"},
601
+ },
602
+ "access" : "readwrite",
603
+ "default" : "",
604
+ "description" :
605
+ """The tag for the target(s) from which to obtain the condition
606
+ for a trigger check.
607
+
608
+ A length of 0 indicates the local system. In this case,
609
+ access to the objects indicated by mteTriggerValueID is under
610
+ the security credentials of the requester that set
611
+ mteTriggerEntryStatus to 'active'. Those credentials are the
612
+ input parameters for isAccessAllowed from the Architecture for
613
+ Describing SNMP Management Frameworks.
614
+
615
+ Otherwise access rights are checked according to the security
616
+
617
+
618
+ parameters resulting from the tag.""",
619
+ }, # column
620
+ "mteTriggerContextName" : {
621
+ "nodetype" : "column",
622
+ "moduleName" : "DISMAN-EVENT-MIB",
623
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.9",
624
+ "status" : "current",
625
+ "syntax" : {
626
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
627
+ },
628
+ "access" : "readwrite",
629
+ "default" : "",
630
+ "description" :
631
+ """The management context from which to obtain mteTriggerValueID.
632
+
633
+ This may be wildcarded by leaving characters off the end. For
634
+ example use 'Repeater' to wildcard to 'Repeater1',
635
+ 'Repeater2', 'Repeater-999.87b', and so on. To indicate such
636
+ wildcarding is intended, mteTriggerContextNameWildcard must
637
+ be 'true'.
638
+
639
+ Each instance that fills the wildcard is independent of any
640
+ additional instances, that is, wildcarded objects operate
641
+ as if there were a separate table entry for each instance
642
+ that fills the wildcard without having to actually predict
643
+ all possible instances ahead of time.
644
+
645
+ Operation of this feature assumes that the local system has a
646
+ list of available contexts against which to apply the
647
+ wildcard. If the objects are being read from the local
648
+ system, this is clearly the system's own list of contexts.
649
+ For a remote system a local version of such a list is not
650
+ defined by any current standard and may not be available, so
651
+ this function MAY not be supported.""",
652
+ }, # column
653
+ "mteTriggerContextNameWildcard" : {
654
+ "nodetype" : "column",
655
+ "moduleName" : "DISMAN-EVENT-MIB",
656
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.10",
657
+ "status" : "current",
658
+ "syntax" : {
659
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
660
+ },
661
+ "access" : "readwrite",
662
+ "default" : "false",
663
+ "description" :
664
+ """Control for whether mteTriggerContextName is to be treated as
665
+ fully-specified or wildcarded, with 'true' indicating wildcard.""",
666
+ }, # column
667
+ "mteTriggerFrequency" : {
668
+ "nodetype" : "column",
669
+ "moduleName" : "DISMAN-EVENT-MIB",
670
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.11",
671
+ "status" : "current",
672
+ "syntax" : {
673
+ "type" : { "module" :"", "name" : "Unsigned32"},
674
+ },
675
+ "access" : "readwrite",
676
+ "default" : "600",
677
+ "units" : "seconds",
678
+ "description" :
679
+ """The number of seconds to wait between trigger samples. To
680
+ encourage consistency in sampling, the interval is measured
681
+ from the beginning of one check to the beginning of the next
682
+ and the timer is restarted immediately when it expires, not
683
+ when the check completes.
684
+
685
+ If the next sample begins before the previous one completed the
686
+ system may either attempt to make the check or treat this as an
687
+ error condition with the error 'sampleOverrun'.
688
+
689
+ A frequency of 0 indicates instantaneous recognition of the
690
+ condition. This is not possible in many cases, but may
691
+ be supported in cases where it makes sense and the system is
692
+ able to do so. This feature allows the MIB to be used in
693
+ implementations where such interrupt-driven behavior is
694
+ possible and is not likely to be supported for all MIB objects
695
+ even then since such sampling generally has to be tightly
696
+ integrated into low-level code.
697
+
698
+ Systems that can support this SHOULD document those cases
699
+ where it can be used. In cases where it can not, setting this
700
+ object to 0 should be disallowed.""",
701
+ }, # column
702
+ "mteTriggerObjectsOwner" : {
703
+ "nodetype" : "column",
704
+ "moduleName" : "DISMAN-EVENT-MIB",
705
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.12",
706
+ "status" : "current",
707
+ "syntax" : {
708
+ "type" : {
709
+ "basetype" : "OctetString",
710
+ "parent module" : {
711
+ "name" : "SNMP-FRAMEWORK-MIB",
712
+ "type" : "SnmpAdminString",
713
+ },
714
+ "ranges" : [
715
+ {
716
+ "min" : "0",
717
+ "max" : "32"
718
+ },
719
+ ],
720
+ "range" : {
721
+ "min" : "0",
722
+ "max" : "32"
723
+ },
724
+ },
725
+ },
726
+ "access" : "readwrite",
727
+ "default" : "",
728
+ "description" :
729
+ """To go with mteTriggerObjects, the mteOwner of a group of
730
+ objects from mteObjectsTable.""",
731
+ }, # column
732
+ "mteTriggerObjects" : {
733
+ "nodetype" : "column",
734
+ "moduleName" : "DISMAN-EVENT-MIB",
735
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.13",
736
+ "status" : "current",
737
+ "syntax" : {
738
+ "type" : {
739
+ "basetype" : "OctetString",
740
+ "parent module" : {
741
+ "name" : "SNMP-FRAMEWORK-MIB",
742
+ "type" : "SnmpAdminString",
743
+ },
744
+ "ranges" : [
745
+ {
746
+ "min" : "0",
747
+ "max" : "32"
748
+ },
749
+ ],
750
+ "range" : {
751
+ "min" : "0",
752
+ "max" : "32"
753
+ },
754
+ },
755
+ },
756
+ "access" : "readwrite",
757
+ "default" : "",
758
+ "description" :
759
+ """The mteObjectsName of a group of objects from
760
+ mteObjectsTable. These objects are to be added to any
761
+ Notification resulting from the firing of this trigger.
762
+
763
+ A list of objects may also be added based on the event or on
764
+ the value of mteTriggerTest.
765
+
766
+
767
+
768
+ A length of 0 indicates no additional objects.""",
769
+ }, # column
770
+ "mteTriggerEnabled" : {
771
+ "nodetype" : "column",
772
+ "moduleName" : "DISMAN-EVENT-MIB",
773
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.14",
774
+ "status" : "current",
775
+ "syntax" : {
776
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
777
+ },
778
+ "access" : "readwrite",
779
+ "default" : "false",
780
+ "description" :
781
+ """A control to allow a trigger to be configured but not used.
782
+ When the value is 'false' the trigger is not sampled.""",
783
+ }, # column
784
+ "mteTriggerEntryStatus" : {
785
+ "nodetype" : "column",
786
+ "moduleName" : "DISMAN-EVENT-MIB",
787
+ "oid" : "1.3.6.1.2.1.88.1.2.2.1.15",
788
+ "status" : "current",
789
+ "syntax" : {
790
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
791
+ },
792
+ "access" : "readwrite",
793
+ "description" :
794
+ """The control that allows creation and deletion of entries.
795
+ Once made active an entry may not be modified except to
796
+ delete it.""",
797
+ }, # column
798
+ "mteTriggerDeltaTable" : {
799
+ "nodetype" : "table",
800
+ "moduleName" : "DISMAN-EVENT-MIB",
801
+ "oid" : "1.3.6.1.2.1.88.1.2.3",
802
+ "status" : "current",
803
+ "description" :
804
+ """A table of management event trigger information for delta
805
+ sampling.""",
806
+ }, # table
807
+ "mteTriggerDeltaEntry" : {
808
+ "nodetype" : "row",
809
+ "moduleName" : "DISMAN-EVENT-MIB",
810
+ "oid" : "1.3.6.1.2.1.88.1.2.3.1",
811
+ "status" : "current",
812
+ "implied" : "true",
813
+ "linkage" : [
814
+ "mteOwner",
815
+ "mteTriggerName",
816
+ ],
817
+ "description" :
818
+ """Information about a single trigger's delta sampling. Entries
819
+ automatically exist in this this table for each mteTriggerEntry
820
+ that has mteTriggerSampleType set to 'deltaValue'.""",
821
+ }, # row
822
+ "mteTriggerDeltaDiscontinuityID" : {
823
+ "nodetype" : "column",
824
+ "moduleName" : "DISMAN-EVENT-MIB",
825
+ "oid" : "1.3.6.1.2.1.88.1.2.3.1.1",
826
+ "status" : "current",
827
+ "syntax" : {
828
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
829
+ },
830
+ "access" : "readwrite",
831
+ "default" : "1.3.6.1.2.1.1.3.0",
832
+ "description" :
833
+ """The OBJECT IDENTIFIER (OID) of a TimeTicks, TimeStamp, or
834
+ DateAndTime object that indicates a discontinuity in the value
835
+ at mteTriggerValueID.
836
+
837
+ The OID may be for a leaf object (e.g. sysUpTime.0) or may
838
+ be wildcarded to match mteTriggerValueID.
839
+
840
+ This object supports normal checking for a discontinuity in a
841
+ counter. Note that if this object does not point to sysUpTime
842
+ discontinuity checking MUST still check sysUpTime for an overall
843
+ discontinuity.
844
+
845
+ If the object identified is not accessible the sample attempt
846
+ is in error, with the error code as from an SNMP request.
847
+
848
+ Bad object identifiers or a mismatch between truncating the
849
+ identifier and the value of mteDeltaDiscontinuityIDWildcard
850
+ result in operation as one would expect when providing the
851
+ wrong identifier to a Get operation. The Get will fail or get
852
+ the wrong object. If the value syntax of those objects is not
853
+ usable, that results in an error that terminates the sample
854
+ with a 'badType' error code.""",
855
+ }, # column
856
+ "mteTriggerDeltaDiscontinuityIDWildcard" : {
857
+ "nodetype" : "column",
858
+ "moduleName" : "DISMAN-EVENT-MIB",
859
+ "oid" : "1.3.6.1.2.1.88.1.2.3.1.2",
860
+ "status" : "current",
861
+ "syntax" : {
862
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
863
+ },
864
+ "access" : "readwrite",
865
+ "default" : "false",
866
+ "description" :
867
+ """Control for whether mteTriggerDeltaDiscontinuityID is to be
868
+ treated as fully-specified or wildcarded, with 'true'
869
+ indicating wildcard. Note that the value of this object will
870
+ be the same as that of the corresponding instance of
871
+ mteTriggerValueIDWildcard when the corresponding
872
+
873
+
874
+ mteTriggerSampleType is 'deltaValue'.""",
875
+ }, # column
876
+ "mteTriggerDeltaDiscontinuityIDType" : {
877
+ "nodetype" : "column",
878
+ "moduleName" : "DISMAN-EVENT-MIB",
879
+ "oid" : "1.3.6.1.2.1.88.1.2.3.1.3",
880
+ "status" : "current",
881
+ "syntax" : {
882
+ "type" : {
883
+ "basetype" : "Enumeration",
884
+ "timeTicks" : {
885
+ "nodetype" : "namednumber",
886
+ "number" : "1"
887
+ },
888
+ "timeStamp" : {
889
+ "nodetype" : "namednumber",
890
+ "number" : "2"
891
+ },
892
+ "dateAndTime" : {
893
+ "nodetype" : "namednumber",
894
+ "number" : "3"
895
+ },
896
+ },
897
+ },
898
+ "access" : "readwrite",
899
+ "default" : "timeTicks",
900
+ "description" :
901
+ """The value 'timeTicks' indicates the
902
+ mteTriggerDeltaDiscontinuityID of this row is of syntax
903
+ TimeTicks. The value 'timeStamp' indicates syntax TimeStamp.
904
+ The value 'dateAndTime' indicates syntax DateAndTime.""",
905
+ }, # column
906
+ "mteTriggerExistenceTable" : {
907
+ "nodetype" : "table",
908
+ "moduleName" : "DISMAN-EVENT-MIB",
909
+ "oid" : "1.3.6.1.2.1.88.1.2.4",
910
+ "status" : "current",
911
+ "description" :
912
+ """A table of management event trigger information for existence
913
+ triggers.""",
914
+ }, # table
915
+ "mteTriggerExistenceEntry" : {
916
+ "nodetype" : "row",
917
+ "moduleName" : "DISMAN-EVENT-MIB",
918
+ "oid" : "1.3.6.1.2.1.88.1.2.4.1",
919
+ "status" : "current",
920
+ "implied" : "true",
921
+ "linkage" : [
922
+ "mteOwner",
923
+ "mteTriggerName",
924
+ ],
925
+ "description" :
926
+ """Information about a single existence trigger. Entries
927
+ automatically exist in this this table for each mteTriggerEntry
928
+ that has 'existence' set in mteTriggerTest.""",
929
+ }, # row
930
+ "mteTriggerExistenceTest" : {
931
+ "nodetype" : "column",
932
+ "moduleName" : "DISMAN-EVENT-MIB",
933
+ "oid" : "1.3.6.1.2.1.88.1.2.4.1.1",
934
+ "status" : "current",
935
+ "syntax" : {
936
+ "type" : {
937
+ "basetype" : "Bits",
938
+ "present" : {
939
+ "nodetype" : "namednumber",
940
+ "number" : "0"
941
+ },
942
+ "absent" : {
943
+ "nodetype" : "namednumber",
944
+ "number" : "1"
945
+ },
946
+ "changed" : {
947
+ "nodetype" : "namednumber",
948
+ "number" : "2"
949
+ },
950
+ },
951
+ },
952
+ "access" : "readwrite",
953
+ "default" : "(present, absent)",
954
+ "description" :
955
+ """The type of existence test to perform. The trigger fires
956
+ when the object at mteTriggerValueID is seen to go from
957
+ present to absent, from absent to present, or to have it's
958
+ value changed, depending on which tests are selected:
959
+
960
+ present(0) - when this test is selected, the trigger fires
961
+ when the mteTriggerValueID object goes from absent to present.
962
+
963
+ absent(1) - when this test is selected, the trigger fires
964
+ when the mteTriggerValueID object goes from present to absent.
965
+ changed(2) - when this test is selected, the trigger fires
966
+ the mteTriggerValueID object value changes.
967
+
968
+ Once the trigger has fired for either presence or absence it
969
+ will not fire again for that state until the object has been
970
+ to the other state. """,
971
+ }, # column
972
+ "mteTriggerExistenceStartup" : {
973
+ "nodetype" : "column",
974
+ "moduleName" : "DISMAN-EVENT-MIB",
975
+ "oid" : "1.3.6.1.2.1.88.1.2.4.1.2",
976
+ "status" : "current",
977
+ "syntax" : {
978
+ "type" : {
979
+ "basetype" : "Bits",
980
+ "present" : {
981
+ "nodetype" : "namednumber",
982
+ "number" : "0"
983
+ },
984
+ "absent" : {
985
+ "nodetype" : "namednumber",
986
+ "number" : "1"
987
+ },
988
+ },
989
+ },
990
+ "access" : "readwrite",
991
+ "default" : "(present, absent)",
992
+ "description" :
993
+ """Control for whether an event may be triggered when this entry
994
+ is first set to 'active' and the test specified by
995
+ mteTriggerExistenceTest is true. Setting an option causes
996
+ that trigger to fire when its test is true.""",
997
+ }, # column
998
+ "mteTriggerExistenceObjectsOwner" : {
999
+ "nodetype" : "column",
1000
+ "moduleName" : "DISMAN-EVENT-MIB",
1001
+ "oid" : "1.3.6.1.2.1.88.1.2.4.1.3",
1002
+ "status" : "current",
1003
+ "syntax" : {
1004
+ "type" : {
1005
+ "basetype" : "OctetString",
1006
+ "parent module" : {
1007
+ "name" : "SNMP-FRAMEWORK-MIB",
1008
+ "type" : "SnmpAdminString",
1009
+ },
1010
+ "ranges" : [
1011
+ {
1012
+ "min" : "0",
1013
+ "max" : "32"
1014
+ },
1015
+ ],
1016
+ "range" : {
1017
+ "min" : "0",
1018
+ "max" : "32"
1019
+ },
1020
+ },
1021
+ },
1022
+ "access" : "readwrite",
1023
+ "default" : "",
1024
+ "description" :
1025
+ """To go with mteTriggerExistenceObjects, the mteOwner of a
1026
+ group of objects from mteObjectsTable.""",
1027
+ }, # column
1028
+ "mteTriggerExistenceObjects" : {
1029
+ "nodetype" : "column",
1030
+ "moduleName" : "DISMAN-EVENT-MIB",
1031
+ "oid" : "1.3.6.1.2.1.88.1.2.4.1.4",
1032
+ "status" : "current",
1033
+ "syntax" : {
1034
+ "type" : {
1035
+ "basetype" : "OctetString",
1036
+ "parent module" : {
1037
+ "name" : "SNMP-FRAMEWORK-MIB",
1038
+ "type" : "SnmpAdminString",
1039
+ },
1040
+ "ranges" : [
1041
+ {
1042
+ "min" : "0",
1043
+ "max" : "32"
1044
+ },
1045
+ ],
1046
+ "range" : {
1047
+ "min" : "0",
1048
+ "max" : "32"
1049
+ },
1050
+ },
1051
+ },
1052
+ "access" : "readwrite",
1053
+ "default" : "",
1054
+ "description" :
1055
+ """The mteObjectsName of a group of objects from
1056
+ mteObjectsTable. These objects are to be added to any
1057
+ Notification resulting from the firing of this trigger for
1058
+ this test.
1059
+
1060
+ A list of objects may also be added based on the overall
1061
+ trigger, the event or other settings in mteTriggerTest.
1062
+
1063
+ A length of 0 indicates no additional objects.""",
1064
+ }, # column
1065
+ "mteTriggerExistenceEventOwner" : {
1066
+ "nodetype" : "column",
1067
+ "moduleName" : "DISMAN-EVENT-MIB",
1068
+ "oid" : "1.3.6.1.2.1.88.1.2.4.1.5",
1069
+ "status" : "current",
1070
+ "syntax" : {
1071
+ "type" : {
1072
+ "basetype" : "OctetString",
1073
+ "parent module" : {
1074
+ "name" : "SNMP-FRAMEWORK-MIB",
1075
+ "type" : "SnmpAdminString",
1076
+ },
1077
+ "ranges" : [
1078
+ {
1079
+ "min" : "0",
1080
+ "max" : "32"
1081
+ },
1082
+ ],
1083
+ "range" : {
1084
+ "min" : "0",
1085
+ "max" : "32"
1086
+ },
1087
+ },
1088
+ },
1089
+ "access" : "readwrite",
1090
+ "default" : "",
1091
+ "description" :
1092
+ """To go with mteTriggerExistenceEvent, the mteOwner of an event
1093
+ entry from the mteEventTable.""",
1094
+ }, # column
1095
+ "mteTriggerExistenceEvent" : {
1096
+ "nodetype" : "column",
1097
+ "moduleName" : "DISMAN-EVENT-MIB",
1098
+ "oid" : "1.3.6.1.2.1.88.1.2.4.1.6",
1099
+ "status" : "current",
1100
+ "syntax" : {
1101
+ "type" : {
1102
+ "basetype" : "OctetString",
1103
+ "parent module" : {
1104
+ "name" : "SNMP-FRAMEWORK-MIB",
1105
+ "type" : "SnmpAdminString",
1106
+ },
1107
+ "ranges" : [
1108
+ {
1109
+ "min" : "0",
1110
+ "max" : "32"
1111
+ },
1112
+ ],
1113
+ "range" : {
1114
+ "min" : "0",
1115
+ "max" : "32"
1116
+ },
1117
+ },
1118
+ },
1119
+ "access" : "readwrite",
1120
+ "default" : "",
1121
+ "description" :
1122
+ """The mteEventName of the event to invoke when mteTriggerType is
1123
+ 'existence' and this trigger fires. A length of 0 indicates no
1124
+ event.""",
1125
+ }, # column
1126
+ "mteTriggerBooleanTable" : {
1127
+ "nodetype" : "table",
1128
+ "moduleName" : "DISMAN-EVENT-MIB",
1129
+ "oid" : "1.3.6.1.2.1.88.1.2.5",
1130
+ "status" : "current",
1131
+ "description" :
1132
+ """A table of management event trigger information for boolean
1133
+ triggers.""",
1134
+ }, # table
1135
+ "mteTriggerBooleanEntry" : {
1136
+ "nodetype" : "row",
1137
+ "moduleName" : "DISMAN-EVENT-MIB",
1138
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1",
1139
+ "status" : "current",
1140
+ "implied" : "true",
1141
+ "linkage" : [
1142
+ "mteOwner",
1143
+ "mteTriggerName",
1144
+ ],
1145
+ "description" :
1146
+ """Information about a single boolean trigger. Entries
1147
+ automatically exist in this this table for each mteTriggerEntry
1148
+ that has 'boolean' set in mteTriggerTest.""",
1149
+ }, # row
1150
+ "mteTriggerBooleanComparison" : {
1151
+ "nodetype" : "column",
1152
+ "moduleName" : "DISMAN-EVENT-MIB",
1153
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1.1",
1154
+ "status" : "current",
1155
+ "syntax" : {
1156
+ "type" : {
1157
+ "basetype" : "Enumeration",
1158
+ "unequal" : {
1159
+ "nodetype" : "namednumber",
1160
+ "number" : "1"
1161
+ },
1162
+ "equal" : {
1163
+ "nodetype" : "namednumber",
1164
+ "number" : "2"
1165
+ },
1166
+ "less" : {
1167
+ "nodetype" : "namednumber",
1168
+ "number" : "3"
1169
+ },
1170
+ "lessOrEqual" : {
1171
+ "nodetype" : "namednumber",
1172
+ "number" : "4"
1173
+ },
1174
+ "greater" : {
1175
+ "nodetype" : "namednumber",
1176
+ "number" : "5"
1177
+ },
1178
+ "greaterOrEqual" : {
1179
+ "nodetype" : "namednumber",
1180
+ "number" : "6"
1181
+ },
1182
+ },
1183
+ },
1184
+ "access" : "readwrite",
1185
+ "default" : "unequal",
1186
+ "description" :
1187
+ """The type of boolean comparison to perform.
1188
+
1189
+ The value at mteTriggerValueID is compared to
1190
+ mteTriggerBooleanValue, so for example if
1191
+ mteTriggerBooleanComparison is 'less' the result would be true
1192
+ if the value at mteTriggerValueID is less than the value of
1193
+ mteTriggerBooleanValue.""",
1194
+ }, # column
1195
+ "mteTriggerBooleanValue" : {
1196
+ "nodetype" : "column",
1197
+ "moduleName" : "DISMAN-EVENT-MIB",
1198
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1.2",
1199
+ "status" : "current",
1200
+ "syntax" : {
1201
+ "type" : { "module" :"", "name" : "Integer32"},
1202
+ },
1203
+ "access" : "readwrite",
1204
+ "default" : "0",
1205
+ "description" :
1206
+ """The value to use for the test specified by
1207
+ mteTriggerBooleanTest.""",
1208
+ }, # column
1209
+ "mteTriggerBooleanStartup" : {
1210
+ "nodetype" : "column",
1211
+ "moduleName" : "DISMAN-EVENT-MIB",
1212
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1.3",
1213
+ "status" : "current",
1214
+ "syntax" : {
1215
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
1216
+ },
1217
+ "access" : "readwrite",
1218
+ "default" : "true",
1219
+ "description" :
1220
+ """Control for whether an event may be triggered when this entry
1221
+ is first set to 'active' or a new instance of the object at
1222
+ mteTriggerValueID is found and the test specified by
1223
+ mteTriggerBooleanComparison is true. In that case an event is
1224
+ triggered if mteTriggerBooleanStartup is 'true'.""",
1225
+ }, # column
1226
+ "mteTriggerBooleanObjectsOwner" : {
1227
+ "nodetype" : "column",
1228
+ "moduleName" : "DISMAN-EVENT-MIB",
1229
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1.4",
1230
+ "status" : "current",
1231
+ "syntax" : {
1232
+ "type" : {
1233
+ "basetype" : "OctetString",
1234
+ "parent module" : {
1235
+ "name" : "SNMP-FRAMEWORK-MIB",
1236
+ "type" : "SnmpAdminString",
1237
+ },
1238
+ "ranges" : [
1239
+ {
1240
+ "min" : "0",
1241
+ "max" : "32"
1242
+ },
1243
+ ],
1244
+ "range" : {
1245
+ "min" : "0",
1246
+ "max" : "32"
1247
+ },
1248
+ },
1249
+ },
1250
+ "access" : "readwrite",
1251
+ "default" : "",
1252
+ "description" :
1253
+ """To go with mteTriggerBooleanObjects, the mteOwner of a group
1254
+ of objects from mteObjectsTable.""",
1255
+ }, # column
1256
+ "mteTriggerBooleanObjects" : {
1257
+ "nodetype" : "column",
1258
+ "moduleName" : "DISMAN-EVENT-MIB",
1259
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1.5",
1260
+ "status" : "current",
1261
+ "syntax" : {
1262
+ "type" : {
1263
+ "basetype" : "OctetString",
1264
+ "parent module" : {
1265
+ "name" : "SNMP-FRAMEWORK-MIB",
1266
+ "type" : "SnmpAdminString",
1267
+ },
1268
+ "ranges" : [
1269
+ {
1270
+ "min" : "0",
1271
+ "max" : "32"
1272
+ },
1273
+ ],
1274
+ "range" : {
1275
+ "min" : "0",
1276
+ "max" : "32"
1277
+ },
1278
+ },
1279
+ },
1280
+ "access" : "readwrite",
1281
+ "default" : "",
1282
+ "description" :
1283
+ """The mteObjectsName of a group of objects from
1284
+ mteObjectsTable. These objects are to be added to any
1285
+ Notification resulting from the firing of this trigger for
1286
+ this test.
1287
+
1288
+ A list of objects may also be added based on the overall
1289
+ trigger, the event or other settings in mteTriggerTest.
1290
+
1291
+ A length of 0 indicates no additional objects.""",
1292
+ }, # column
1293
+ "mteTriggerBooleanEventOwner" : {
1294
+ "nodetype" : "column",
1295
+ "moduleName" : "DISMAN-EVENT-MIB",
1296
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1.6",
1297
+ "status" : "current",
1298
+ "syntax" : {
1299
+ "type" : {
1300
+ "basetype" : "OctetString",
1301
+ "parent module" : {
1302
+ "name" : "SNMP-FRAMEWORK-MIB",
1303
+ "type" : "SnmpAdminString",
1304
+ },
1305
+ "ranges" : [
1306
+ {
1307
+ "min" : "0",
1308
+ "max" : "32"
1309
+ },
1310
+ ],
1311
+ "range" : {
1312
+ "min" : "0",
1313
+ "max" : "32"
1314
+ },
1315
+ },
1316
+ },
1317
+ "access" : "readwrite",
1318
+ "default" : "",
1319
+ "description" :
1320
+ """To go with mteTriggerBooleanEvent, the mteOwner of an event
1321
+ entry from mteEventTable.""",
1322
+ }, # column
1323
+ "mteTriggerBooleanEvent" : {
1324
+ "nodetype" : "column",
1325
+ "moduleName" : "DISMAN-EVENT-MIB",
1326
+ "oid" : "1.3.6.1.2.1.88.1.2.5.1.7",
1327
+ "status" : "current",
1328
+ "syntax" : {
1329
+ "type" : {
1330
+ "basetype" : "OctetString",
1331
+ "parent module" : {
1332
+ "name" : "SNMP-FRAMEWORK-MIB",
1333
+ "type" : "SnmpAdminString",
1334
+ },
1335
+ "ranges" : [
1336
+ {
1337
+ "min" : "0",
1338
+ "max" : "32"
1339
+ },
1340
+ ],
1341
+ "range" : {
1342
+ "min" : "0",
1343
+ "max" : "32"
1344
+ },
1345
+ },
1346
+ },
1347
+ "access" : "readwrite",
1348
+ "default" : "",
1349
+ "description" :
1350
+ """The mteEventName of the event to invoke when mteTriggerType is
1351
+ 'boolean' and this trigger fires. A length of 0 indicates no
1352
+ event.""",
1353
+ }, # column
1354
+ "mteTriggerThresholdTable" : {
1355
+ "nodetype" : "table",
1356
+ "moduleName" : "DISMAN-EVENT-MIB",
1357
+ "oid" : "1.3.6.1.2.1.88.1.2.6",
1358
+ "status" : "current",
1359
+ "description" :
1360
+ """A table of management event trigger information for threshold
1361
+ triggers.""",
1362
+ }, # table
1363
+ "mteTriggerThresholdEntry" : {
1364
+ "nodetype" : "row",
1365
+ "moduleName" : "DISMAN-EVENT-MIB",
1366
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1",
1367
+ "status" : "current",
1368
+ "implied" : "true",
1369
+ "linkage" : [
1370
+ "mteOwner",
1371
+ "mteTriggerName",
1372
+ ],
1373
+ "description" :
1374
+ """Information about a single threshold trigger. Entries
1375
+ automatically exist in this table for each mteTriggerEntry
1376
+ that has 'threshold' set in mteTriggerTest.""",
1377
+ }, # row
1378
+ "mteTriggerThresholdStartup" : {
1379
+ "nodetype" : "column",
1380
+ "moduleName" : "DISMAN-EVENT-MIB",
1381
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.1",
1382
+ "status" : "current",
1383
+ "syntax" : {
1384
+ "type" : {
1385
+ "basetype" : "Enumeration",
1386
+ "rising" : {
1387
+ "nodetype" : "namednumber",
1388
+ "number" : "1"
1389
+ },
1390
+ "falling" : {
1391
+ "nodetype" : "namednumber",
1392
+ "number" : "2"
1393
+ },
1394
+ "risingOrFalling" : {
1395
+ "nodetype" : "namednumber",
1396
+ "number" : "3"
1397
+ },
1398
+ },
1399
+ },
1400
+ "access" : "readwrite",
1401
+ "default" : "risingOrFalling",
1402
+ "description" :
1403
+ """The event that may be triggered when this entry is first
1404
+ set to 'active' and a new instance of the object at
1405
+ mteTriggerValueID is found. If the first sample after this
1406
+ instance becomes active is greater than or equal to
1407
+ mteTriggerThresholdRising and mteTriggerThresholdStartup is
1408
+ equal to 'rising' or 'risingOrFalling', then one
1409
+ mteTriggerThresholdRisingEvent is triggered for that instance.
1410
+ If the first sample after this entry becomes active is less
1411
+ than or equal to mteTriggerThresholdFalling and
1412
+ mteTriggerThresholdStartup is equal to 'falling' or
1413
+ 'risingOrFalling', then one mteTriggerThresholdRisingEvent is
1414
+ triggered for that instance.""",
1415
+ }, # column
1416
+ "mteTriggerThresholdRising" : {
1417
+ "nodetype" : "column",
1418
+ "moduleName" : "DISMAN-EVENT-MIB",
1419
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.2",
1420
+ "status" : "current",
1421
+ "syntax" : {
1422
+ "type" : { "module" :"", "name" : "Integer32"},
1423
+ },
1424
+ "access" : "readwrite",
1425
+ "default" : "0",
1426
+ "description" :
1427
+ """A threshold value to check against if mteTriggerType is
1428
+ 'threshold'.
1429
+
1430
+ When the current sampled value is greater than or equal to
1431
+ this threshold, and the value at the last sampling interval
1432
+ was less than this threshold, one
1433
+ mteTriggerThresholdRisingEvent is triggered. That event is
1434
+ also triggered if the first sample after this entry becomes
1435
+ active is greater than or equal to this threshold and
1436
+ mteTriggerThresholdStartup is equal to 'rising' or
1437
+ 'risingOrFalling'.
1438
+
1439
+ After a rising event is generated, another such event is not
1440
+ triggered until the sampled value falls below this threshold
1441
+ and reaches mteTriggerThresholdFalling.""",
1442
+ }, # column
1443
+ "mteTriggerThresholdFalling" : {
1444
+ "nodetype" : "column",
1445
+ "moduleName" : "DISMAN-EVENT-MIB",
1446
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.3",
1447
+ "status" : "current",
1448
+ "syntax" : {
1449
+ "type" : { "module" :"", "name" : "Integer32"},
1450
+ },
1451
+ "access" : "readwrite",
1452
+ "default" : "0",
1453
+ "description" :
1454
+ """A threshold value to check against if mteTriggerType is
1455
+ 'threshold'.
1456
+
1457
+ When the current sampled value is less than or equal to this
1458
+ threshold, and the value at the last sampling interval was
1459
+ greater than this threshold, one
1460
+ mteTriggerThresholdFallingEvent is triggered. That event is
1461
+ also triggered if the first sample after this entry becomes
1462
+ active is less than or equal to this threshold and
1463
+ mteTriggerThresholdStartup is equal to 'falling' or
1464
+ 'risingOrFalling'.
1465
+
1466
+ After a falling event is generated, another such event is not
1467
+ triggered until the sampled value rises above this threshold
1468
+ and reaches mteTriggerThresholdRising.""",
1469
+ }, # column
1470
+ "mteTriggerThresholdDeltaRising" : {
1471
+ "nodetype" : "column",
1472
+ "moduleName" : "DISMAN-EVENT-MIB",
1473
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.4",
1474
+ "status" : "current",
1475
+ "syntax" : {
1476
+ "type" : { "module" :"", "name" : "Integer32"},
1477
+ },
1478
+ "access" : "readwrite",
1479
+ "default" : "0",
1480
+ "description" :
1481
+ """A threshold value to check against if mteTriggerType is
1482
+ 'threshold'.
1483
+
1484
+ When the delta value (difference) between the current sampled
1485
+ value (value(n)) and the previous sampled value (value(n-1))
1486
+ is greater than or equal to this threshold,
1487
+ and the delta value calculated at the last sampling interval
1488
+ (i.e. value(n-1) - value(n-2)) was less than this threshold,
1489
+ one mteTriggerThresholdDeltaRisingEvent is triggered. That event
1490
+ is also triggered if the first delta value calculated after this
1491
+ entry becomes active, i.e. value(2) - value(1), where value(1)
1492
+ is the first sample taken of that instance, is greater than or
1493
+ equal to this threshold.
1494
+
1495
+ After a rising event is generated, another such event is not
1496
+ triggered until the delta value falls below this threshold and
1497
+ reaches mteTriggerThresholdDeltaFalling.""",
1498
+ }, # column
1499
+ "mteTriggerThresholdDeltaFalling" : {
1500
+ "nodetype" : "column",
1501
+ "moduleName" : "DISMAN-EVENT-MIB",
1502
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.5",
1503
+ "status" : "current",
1504
+ "syntax" : {
1505
+ "type" : { "module" :"", "name" : "Integer32"},
1506
+ },
1507
+ "access" : "readwrite",
1508
+ "default" : "0",
1509
+ "description" :
1510
+ """A threshold value to check against if mteTriggerType is
1511
+ 'threshold'.
1512
+
1513
+ When the delta value (difference) between the current sampled
1514
+ value (value(n)) and the previous sampled value (value(n-1))
1515
+ is less than or equal to this threshold,
1516
+ and the delta value calculated at the last sampling interval
1517
+ (i.e. value(n-1) - value(n-2)) was greater than this threshold,
1518
+ one mteTriggerThresholdDeltaFallingEvent is triggered. That event
1519
+ is also triggered if the first delta value calculated after this
1520
+ entry becomes active, i.e. value(2) - value(1), where value(1)
1521
+ is the first sample taken of that instance, is less than or
1522
+ equal to this threshold.
1523
+
1524
+ After a falling event is generated, another such event is not
1525
+ triggered until the delta value falls below this threshold and
1526
+ reaches mteTriggerThresholdDeltaRising.""",
1527
+ }, # column
1528
+ "mteTriggerThresholdObjectsOwner" : {
1529
+ "nodetype" : "column",
1530
+ "moduleName" : "DISMAN-EVENT-MIB",
1531
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.6",
1532
+ "status" : "current",
1533
+ "syntax" : {
1534
+ "type" : {
1535
+ "basetype" : "OctetString",
1536
+ "parent module" : {
1537
+ "name" : "SNMP-FRAMEWORK-MIB",
1538
+ "type" : "SnmpAdminString",
1539
+ },
1540
+ "ranges" : [
1541
+ {
1542
+ "min" : "0",
1543
+ "max" : "32"
1544
+ },
1545
+ ],
1546
+ "range" : {
1547
+ "min" : "0",
1548
+ "max" : "32"
1549
+ },
1550
+ },
1551
+ },
1552
+ "access" : "readwrite",
1553
+ "default" : "",
1554
+ "description" :
1555
+ """To go with mteTriggerThresholdObjects, the mteOwner of a group
1556
+ of objects from mteObjectsTable.""",
1557
+ }, # column
1558
+ "mteTriggerThresholdObjects" : {
1559
+ "nodetype" : "column",
1560
+ "moduleName" : "DISMAN-EVENT-MIB",
1561
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.7",
1562
+ "status" : "current",
1563
+ "syntax" : {
1564
+ "type" : {
1565
+ "basetype" : "OctetString",
1566
+ "parent module" : {
1567
+ "name" : "SNMP-FRAMEWORK-MIB",
1568
+ "type" : "SnmpAdminString",
1569
+ },
1570
+ "ranges" : [
1571
+ {
1572
+ "min" : "0",
1573
+ "max" : "32"
1574
+ },
1575
+ ],
1576
+ "range" : {
1577
+ "min" : "0",
1578
+ "max" : "32"
1579
+ },
1580
+ },
1581
+ },
1582
+ "access" : "readwrite",
1583
+ "default" : "",
1584
+ "description" :
1585
+ """The mteObjectsName of a group of objects from
1586
+ mteObjectsTable. These objects are to be added to any
1587
+ Notification resulting from the firing of this trigger for
1588
+ this test.
1589
+
1590
+ A list of objects may also be added based on the overall
1591
+
1592
+
1593
+ trigger, the event or other settings in mteTriggerTest.
1594
+
1595
+ A length of 0 indicates no additional objects.""",
1596
+ }, # column
1597
+ "mteTriggerThresholdRisingEventOwner" : {
1598
+ "nodetype" : "column",
1599
+ "moduleName" : "DISMAN-EVENT-MIB",
1600
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.8",
1601
+ "status" : "current",
1602
+ "syntax" : {
1603
+ "type" : {
1604
+ "basetype" : "OctetString",
1605
+ "parent module" : {
1606
+ "name" : "SNMP-FRAMEWORK-MIB",
1607
+ "type" : "SnmpAdminString",
1608
+ },
1609
+ "ranges" : [
1610
+ {
1611
+ "min" : "0",
1612
+ "max" : "32"
1613
+ },
1614
+ ],
1615
+ "range" : {
1616
+ "min" : "0",
1617
+ "max" : "32"
1618
+ },
1619
+ },
1620
+ },
1621
+ "access" : "readwrite",
1622
+ "default" : "",
1623
+ "description" :
1624
+ """To go with mteTriggerThresholdRisingEvent, the mteOwner of an
1625
+ event entry from mteEventTable.""",
1626
+ }, # column
1627
+ "mteTriggerThresholdRisingEvent" : {
1628
+ "nodetype" : "column",
1629
+ "moduleName" : "DISMAN-EVENT-MIB",
1630
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.9",
1631
+ "status" : "current",
1632
+ "syntax" : {
1633
+ "type" : {
1634
+ "basetype" : "OctetString",
1635
+ "parent module" : {
1636
+ "name" : "SNMP-FRAMEWORK-MIB",
1637
+ "type" : "SnmpAdminString",
1638
+ },
1639
+ "ranges" : [
1640
+ {
1641
+ "min" : "0",
1642
+ "max" : "32"
1643
+ },
1644
+ ],
1645
+ "range" : {
1646
+ "min" : "0",
1647
+ "max" : "32"
1648
+ },
1649
+ },
1650
+ },
1651
+ "access" : "readwrite",
1652
+ "default" : "",
1653
+ "description" :
1654
+ """The mteEventName of the event to invoke when mteTriggerType is
1655
+ 'threshold' and this trigger fires based on
1656
+ mteTriggerThresholdRising. A length of 0 indicates no event.""",
1657
+ }, # column
1658
+ "mteTriggerThresholdFallingEventOwner" : {
1659
+ "nodetype" : "column",
1660
+ "moduleName" : "DISMAN-EVENT-MIB",
1661
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.10",
1662
+ "status" : "current",
1663
+ "syntax" : {
1664
+ "type" : {
1665
+ "basetype" : "OctetString",
1666
+ "parent module" : {
1667
+ "name" : "SNMP-FRAMEWORK-MIB",
1668
+ "type" : "SnmpAdminString",
1669
+ },
1670
+ "ranges" : [
1671
+ {
1672
+ "min" : "0",
1673
+ "max" : "32"
1674
+ },
1675
+ ],
1676
+ "range" : {
1677
+ "min" : "0",
1678
+ "max" : "32"
1679
+ },
1680
+ },
1681
+ },
1682
+ "access" : "readwrite",
1683
+ "default" : "",
1684
+ "description" :
1685
+ """To go with mteTriggerThresholdFallingEvent, the mteOwner of an
1686
+ event entry from mteEventTable.""",
1687
+ }, # column
1688
+ "mteTriggerThresholdFallingEvent" : {
1689
+ "nodetype" : "column",
1690
+ "moduleName" : "DISMAN-EVENT-MIB",
1691
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.11",
1692
+ "status" : "current",
1693
+ "syntax" : {
1694
+ "type" : {
1695
+ "basetype" : "OctetString",
1696
+ "parent module" : {
1697
+ "name" : "SNMP-FRAMEWORK-MIB",
1698
+ "type" : "SnmpAdminString",
1699
+ },
1700
+ "ranges" : [
1701
+ {
1702
+ "min" : "0",
1703
+ "max" : "32"
1704
+ },
1705
+ ],
1706
+ "range" : {
1707
+ "min" : "0",
1708
+ "max" : "32"
1709
+ },
1710
+ },
1711
+ },
1712
+ "access" : "readwrite",
1713
+ "default" : "",
1714
+ "description" :
1715
+ """The mteEventName of the event to invoke when mteTriggerType is
1716
+ 'threshold' and this trigger fires based on
1717
+ mteTriggerThresholdFalling. A length of 0 indicates no event.""",
1718
+ }, # column
1719
+ "mteTriggerThresholdDeltaRisingEventOwner" : {
1720
+ "nodetype" : "column",
1721
+ "moduleName" : "DISMAN-EVENT-MIB",
1722
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.12",
1723
+ "status" : "current",
1724
+ "syntax" : {
1725
+ "type" : {
1726
+ "basetype" : "OctetString",
1727
+ "parent module" : {
1728
+ "name" : "SNMP-FRAMEWORK-MIB",
1729
+ "type" : "SnmpAdminString",
1730
+ },
1731
+ "ranges" : [
1732
+ {
1733
+ "min" : "0",
1734
+ "max" : "32"
1735
+ },
1736
+ ],
1737
+ "range" : {
1738
+ "min" : "0",
1739
+ "max" : "32"
1740
+ },
1741
+ },
1742
+ },
1743
+ "access" : "readwrite",
1744
+ "default" : "",
1745
+ "description" :
1746
+ """To go with mteTriggerThresholdDeltaRisingEvent, the mteOwner
1747
+ of an event entry from mteEventTable.""",
1748
+ }, # column
1749
+ "mteTriggerThresholdDeltaRisingEvent" : {
1750
+ "nodetype" : "column",
1751
+ "moduleName" : "DISMAN-EVENT-MIB",
1752
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.13",
1753
+ "status" : "current",
1754
+ "syntax" : {
1755
+ "type" : {
1756
+ "basetype" : "OctetString",
1757
+ "parent module" : {
1758
+ "name" : "SNMP-FRAMEWORK-MIB",
1759
+ "type" : "SnmpAdminString",
1760
+ },
1761
+ "ranges" : [
1762
+ {
1763
+ "min" : "0",
1764
+ "max" : "32"
1765
+ },
1766
+ ],
1767
+ "range" : {
1768
+ "min" : "0",
1769
+ "max" : "32"
1770
+ },
1771
+ },
1772
+ },
1773
+ "access" : "readwrite",
1774
+ "default" : "",
1775
+ "description" :
1776
+ """The mteEventName of the event to invoke when mteTriggerType is
1777
+ 'threshold' and this trigger fires based on
1778
+ mteTriggerThresholdDeltaRising. A length of 0 indicates
1779
+ no event.""",
1780
+ }, # column
1781
+ "mteTriggerThresholdDeltaFallingEventOwner" : {
1782
+ "nodetype" : "column",
1783
+ "moduleName" : "DISMAN-EVENT-MIB",
1784
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.14",
1785
+ "status" : "current",
1786
+ "syntax" : {
1787
+ "type" : {
1788
+ "basetype" : "OctetString",
1789
+ "parent module" : {
1790
+ "name" : "SNMP-FRAMEWORK-MIB",
1791
+ "type" : "SnmpAdminString",
1792
+ },
1793
+ "ranges" : [
1794
+ {
1795
+ "min" : "0",
1796
+ "max" : "32"
1797
+ },
1798
+ ],
1799
+ "range" : {
1800
+ "min" : "0",
1801
+ "max" : "32"
1802
+ },
1803
+ },
1804
+ },
1805
+ "access" : "readwrite",
1806
+ "default" : "",
1807
+ "description" :
1808
+ """To go with mteTriggerThresholdDeltaFallingEvent, the mteOwner
1809
+ of an event entry from mteEventTable.""",
1810
+ }, # column
1811
+ "mteTriggerThresholdDeltaFallingEvent" : {
1812
+ "nodetype" : "column",
1813
+ "moduleName" : "DISMAN-EVENT-MIB",
1814
+ "oid" : "1.3.6.1.2.1.88.1.2.6.1.15",
1815
+ "status" : "current",
1816
+ "syntax" : {
1817
+ "type" : {
1818
+ "basetype" : "OctetString",
1819
+ "parent module" : {
1820
+ "name" : "SNMP-FRAMEWORK-MIB",
1821
+ "type" : "SnmpAdminString",
1822
+ },
1823
+ "ranges" : [
1824
+ {
1825
+ "min" : "0",
1826
+ "max" : "32"
1827
+ },
1828
+ ],
1829
+ "range" : {
1830
+ "min" : "0",
1831
+ "max" : "32"
1832
+ },
1833
+ },
1834
+ },
1835
+ "access" : "readwrite",
1836
+ "default" : "",
1837
+ "description" :
1838
+ """The mteEventName of the event to invoke when mteTriggerType is
1839
+ 'threshold' and this trigger fires based on
1840
+ mteTriggerThresholdDeltaFalling. A length of 0 indicates
1841
+ no event.""",
1842
+ }, # column
1843
+ "mteObjects" : {
1844
+ "nodetype" : "node",
1845
+ "moduleName" : "DISMAN-EVENT-MIB",
1846
+ "oid" : "1.3.6.1.2.1.88.1.3",
1847
+ }, # node
1848
+ "mteObjectsTable" : {
1849
+ "nodetype" : "table",
1850
+ "moduleName" : "DISMAN-EVENT-MIB",
1851
+ "oid" : "1.3.6.1.2.1.88.1.3.1",
1852
+ "status" : "current",
1853
+ "description" :
1854
+ """A table of objects that can be added to notifications based
1855
+ on the trigger, trigger test, or event, as pointed to by
1856
+ entries in those tables.""",
1857
+ }, # table
1858
+ "mteObjectsEntry" : {
1859
+ "nodetype" : "row",
1860
+ "moduleName" : "DISMAN-EVENT-MIB",
1861
+ "oid" : "1.3.6.1.2.1.88.1.3.1.1",
1862
+ "create" : "true",
1863
+ "status" : "current",
1864
+ "linkage" : [
1865
+ "mteOwner",
1866
+ "mteObjectsName",
1867
+ "mteObjectsIndex",
1868
+ ],
1869
+ "description" :
1870
+ """A group of objects. Applications create and delete entries
1871
+ using mteObjectsEntryStatus.
1872
+
1873
+ When adding objects to a notification they are added in the
1874
+ lexical order of their index in this table. Those associated
1875
+ with a trigger come first, then trigger test, then event.""",
1876
+ }, # row
1877
+ "mteObjectsName" : {
1878
+ "nodetype" : "column",
1879
+ "moduleName" : "DISMAN-EVENT-MIB",
1880
+ "oid" : "1.3.6.1.2.1.88.1.3.1.1.1",
1881
+ "status" : "current",
1882
+ "syntax" : {
1883
+ "type" : {
1884
+ "basetype" : "OctetString",
1885
+ "parent module" : {
1886
+ "name" : "SNMP-FRAMEWORK-MIB",
1887
+ "type" : "SnmpAdminString",
1888
+ },
1889
+ "ranges" : [
1890
+ {
1891
+ "min" : "1",
1892
+ "max" : "32"
1893
+ },
1894
+ ],
1895
+ "range" : {
1896
+ "min" : "1",
1897
+ "max" : "32"
1898
+ },
1899
+ },
1900
+ },
1901
+ "access" : "noaccess",
1902
+ "description" :
1903
+ """A locally-unique, administratively assigned name for a group
1904
+ of objects.""",
1905
+ }, # column
1906
+ "mteObjectsIndex" : {
1907
+ "nodetype" : "column",
1908
+ "moduleName" : "DISMAN-EVENT-MIB",
1909
+ "oid" : "1.3.6.1.2.1.88.1.3.1.1.2",
1910
+ "status" : "current",
1911
+ "syntax" : {
1912
+ "type" : {
1913
+ "basetype" : "Unsigned32",
1914
+ "ranges" : [
1915
+ {
1916
+ "min" : "1",
1917
+ "max" : "4294967295"
1918
+ },
1919
+ ],
1920
+ "range" : {
1921
+ "min" : "1",
1922
+ "max" : "4294967295"
1923
+ },
1924
+ },
1925
+ },
1926
+ "access" : "noaccess",
1927
+ "description" :
1928
+ """An arbitrary integer for the purpose of identifying
1929
+ individual objects within a mteObjectsName group.
1930
+
1931
+
1932
+ Objects within a group are placed in the notification in the
1933
+ numerical order of this index.
1934
+
1935
+ Groups are placed in the notification in the order of the
1936
+ selections for overall trigger, trigger test, and event.
1937
+ Within trigger test they are in the same order as the
1938
+ numerical values of the bits defined for mteTriggerTest.
1939
+
1940
+ Bad object identifiers or a mismatch between truncating the
1941
+ identifier and the value of mteDeltaDiscontinuityIDWildcard
1942
+ result in operation as one would expect when providing the
1943
+ wrong identifier to a Get operation. The Get will fail or get
1944
+ the wrong object. If the object is not available it is omitted
1945
+ from the notification.""",
1946
+ }, # column
1947
+ "mteObjectsID" : {
1948
+ "nodetype" : "column",
1949
+ "moduleName" : "DISMAN-EVENT-MIB",
1950
+ "oid" : "1.3.6.1.2.1.88.1.3.1.1.3",
1951
+ "status" : "current",
1952
+ "syntax" : {
1953
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
1954
+ },
1955
+ "access" : "readwrite",
1956
+ "default" : "0.0",
1957
+ "description" :
1958
+ """The object identifier of a MIB object to add to a
1959
+ Notification that results from the firing of a trigger.
1960
+
1961
+ This may be wildcarded by truncating all or part of the
1962
+ instance portion, in which case the instance portion of the
1963
+ OID for obtaining this object will be the same as that used
1964
+ in obtaining the mteTriggerValueID that fired. If such
1965
+ wildcarding is applied, mteObjectsIDWildcard must be
1966
+ 'true' and if not it must be 'false'.
1967
+
1968
+ Each instance that fills the wildcard is independent of any
1969
+ additional instances, that is, wildcarded objects operate
1970
+ as if there were a separate table entry for each instance
1971
+ that fills the wildcard without having to actually predict
1972
+ all possible instances ahead of time.""",
1973
+ }, # column
1974
+ "mteObjectsIDWildcard" : {
1975
+ "nodetype" : "column",
1976
+ "moduleName" : "DISMAN-EVENT-MIB",
1977
+ "oid" : "1.3.6.1.2.1.88.1.3.1.1.4",
1978
+ "status" : "current",
1979
+ "syntax" : {
1980
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
1981
+ },
1982
+ "access" : "readwrite",
1983
+ "default" : "false",
1984
+ "description" :
1985
+ """Control for whether mteObjectsID is to be treated as
1986
+ fully-specified or wildcarded, with 'true' indicating wildcard.""",
1987
+ }, # column
1988
+ "mteObjectsEntryStatus" : {
1989
+ "nodetype" : "column",
1990
+ "moduleName" : "DISMAN-EVENT-MIB",
1991
+ "oid" : "1.3.6.1.2.1.88.1.3.1.1.5",
1992
+ "status" : "current",
1993
+ "syntax" : {
1994
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
1995
+ },
1996
+ "access" : "readwrite",
1997
+ "description" :
1998
+ """The control that allows creation and deletion of entries.
1999
+ Once made active an entry MAY not be modified except to
2000
+ delete it.""",
2001
+ }, # column
2002
+ "mteEvent" : {
2003
+ "nodetype" : "node",
2004
+ "moduleName" : "DISMAN-EVENT-MIB",
2005
+ "oid" : "1.3.6.1.2.1.88.1.4",
2006
+ }, # node
2007
+ "mteEventFailures" : {
2008
+ "nodetype" : "scalar",
2009
+ "moduleName" : "DISMAN-EVENT-MIB",
2010
+ "oid" : "1.3.6.1.2.1.88.1.4.1",
2011
+ "status" : "current",
2012
+ "syntax" : {
2013
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
2014
+ },
2015
+ "access" : "readonly",
2016
+ "description" :
2017
+ """The number of times an attempt to invoke an event
2018
+ has failed. This counts individually for each
2019
+ attempt in a group of targets or each attempt for a
2020
+ wildcarded trigger object.""",
2021
+ }, # scalar
2022
+ "mteEventTable" : {
2023
+ "nodetype" : "table",
2024
+ "moduleName" : "DISMAN-EVENT-MIB",
2025
+ "oid" : "1.3.6.1.2.1.88.1.4.2",
2026
+ "status" : "current",
2027
+ "description" :
2028
+ """A table of management event action information.""",
2029
+ }, # table
2030
+ "mteEventEntry" : {
2031
+ "nodetype" : "row",
2032
+ "moduleName" : "DISMAN-EVENT-MIB",
2033
+ "oid" : "1.3.6.1.2.1.88.1.4.2.1",
2034
+ "create" : "true",
2035
+ "status" : "current",
2036
+ "implied" : "true",
2037
+ "linkage" : [
2038
+ "mteOwner",
2039
+ "mteEventName",
2040
+ ],
2041
+ "description" :
2042
+ """Information about a single event. Applications create and
2043
+ delete entries using mteEventEntryStatus.""",
2044
+ }, # row
2045
+ "mteEventName" : {
2046
+ "nodetype" : "column",
2047
+ "moduleName" : "DISMAN-EVENT-MIB",
2048
+ "oid" : "1.3.6.1.2.1.88.1.4.2.1.1",
2049
+ "status" : "current",
2050
+ "syntax" : {
2051
+ "type" : {
2052
+ "basetype" : "OctetString",
2053
+ "parent module" : {
2054
+ "name" : "SNMP-FRAMEWORK-MIB",
2055
+ "type" : "SnmpAdminString",
2056
+ },
2057
+ "ranges" : [
2058
+ {
2059
+ "min" : "1",
2060
+ "max" : "32"
2061
+ },
2062
+ ],
2063
+ "range" : {
2064
+ "min" : "1",
2065
+ "max" : "32"
2066
+ },
2067
+ },
2068
+ },
2069
+ "access" : "noaccess",
2070
+ "description" :
2071
+ """A locally-unique, administratively assigned name for the
2072
+ event.""",
2073
+ }, # column
2074
+ "mteEventComment" : {
2075
+ "nodetype" : "column",
2076
+ "moduleName" : "DISMAN-EVENT-MIB",
2077
+ "oid" : "1.3.6.1.2.1.88.1.4.2.1.2",
2078
+ "status" : "current",
2079
+ "syntax" : {
2080
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
2081
+ },
2082
+ "access" : "readwrite",
2083
+ "default" : "",
2084
+ "description" :
2085
+ """A description of the event's function and use.""",
2086
+ }, # column
2087
+ "mteEventActions" : {
2088
+ "nodetype" : "column",
2089
+ "moduleName" : "DISMAN-EVENT-MIB",
2090
+ "oid" : "1.3.6.1.2.1.88.1.4.2.1.3",
2091
+ "status" : "current",
2092
+ "syntax" : {
2093
+ "type" : {
2094
+ "basetype" : "Bits",
2095
+ "notification" : {
2096
+ "nodetype" : "namednumber",
2097
+ "number" : "0"
2098
+ },
2099
+ "set" : {
2100
+ "nodetype" : "namednumber",
2101
+ "number" : "1"
2102
+ },
2103
+ },
2104
+ },
2105
+ "access" : "readwrite",
2106
+ "default" : "()",
2107
+ "description" :
2108
+ """The actions to perform when this event occurs.
2109
+
2110
+ For 'notification', Traps and/or Informs are sent according
2111
+ to the configuration in the SNMP Notification MIB.
2112
+
2113
+ For 'set', an SNMP Set operation is performed according to
2114
+ control values in this entry.""",
2115
+ }, # column
2116
+ "mteEventEnabled" : {
2117
+ "nodetype" : "column",
2118
+ "moduleName" : "DISMAN-EVENT-MIB",
2119
+ "oid" : "1.3.6.1.2.1.88.1.4.2.1.4",
2120
+ "status" : "current",
2121
+ "syntax" : {
2122
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
2123
+ },
2124
+ "access" : "readwrite",
2125
+ "default" : "false",
2126
+ "description" :
2127
+ """A control to allow an event to be configured but not used.
2128
+ When the value is 'false' the event does not execute even if
2129
+
2130
+
2131
+ triggered.""",
2132
+ }, # column
2133
+ "mteEventEntryStatus" : {
2134
+ "nodetype" : "column",
2135
+ "moduleName" : "DISMAN-EVENT-MIB",
2136
+ "oid" : "1.3.6.1.2.1.88.1.4.2.1.5",
2137
+ "status" : "current",
2138
+ "syntax" : {
2139
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
2140
+ },
2141
+ "access" : "readwrite",
2142
+ "description" :
2143
+ """The control that allows creation and deletion of entries.
2144
+ Once made active an entry MAY not be modified except to
2145
+ delete it.""",
2146
+ }, # column
2147
+ "mteEventNotificationTable" : {
2148
+ "nodetype" : "table",
2149
+ "moduleName" : "DISMAN-EVENT-MIB",
2150
+ "oid" : "1.3.6.1.2.1.88.1.4.3",
2151
+ "status" : "current",
2152
+ "description" :
2153
+ """A table of information about notifications to be sent as a
2154
+ consequence of management events.""",
2155
+ }, # table
2156
+ "mteEventNotificationEntry" : {
2157
+ "nodetype" : "row",
2158
+ "moduleName" : "DISMAN-EVENT-MIB",
2159
+ "oid" : "1.3.6.1.2.1.88.1.4.3.1",
2160
+ "status" : "current",
2161
+ "implied" : "true",
2162
+ "linkage" : [
2163
+ "mteOwner",
2164
+ "mteEventName",
2165
+ ],
2166
+ "description" :
2167
+ """Information about a single event's notification. Entries
2168
+ automatically exist in this this table for each mteEventEntry
2169
+ that has 'notification' set in mteEventActions.""",
2170
+ }, # row
2171
+ "mteEventNotification" : {
2172
+ "nodetype" : "column",
2173
+ "moduleName" : "DISMAN-EVENT-MIB",
2174
+ "oid" : "1.3.6.1.2.1.88.1.4.3.1.1",
2175
+ "status" : "current",
2176
+ "syntax" : {
2177
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
2178
+ },
2179
+ "access" : "readwrite",
2180
+ "default" : "0.0",
2181
+ "description" :
2182
+ """The object identifier from the NOTIFICATION-TYPE for the
2183
+ notification to use if metEventActions has 'notification' set.""",
2184
+ }, # column
2185
+ "mteEventNotificationObjectsOwner" : {
2186
+ "nodetype" : "column",
2187
+ "moduleName" : "DISMAN-EVENT-MIB",
2188
+ "oid" : "1.3.6.1.2.1.88.1.4.3.1.2",
2189
+ "status" : "current",
2190
+ "syntax" : {
2191
+ "type" : {
2192
+ "basetype" : "OctetString",
2193
+ "parent module" : {
2194
+ "name" : "SNMP-FRAMEWORK-MIB",
2195
+ "type" : "SnmpAdminString",
2196
+ },
2197
+ "ranges" : [
2198
+ {
2199
+ "min" : "0",
2200
+ "max" : "32"
2201
+ },
2202
+ ],
2203
+ "range" : {
2204
+ "min" : "0",
2205
+ "max" : "32"
2206
+ },
2207
+ },
2208
+ },
2209
+ "access" : "readwrite",
2210
+ "default" : "",
2211
+ "description" :
2212
+ """To go with mteEventNotificationObjects, the mteOwner of a
2213
+ group of objects from mteObjectsTable.""",
2214
+ }, # column
2215
+ "mteEventNotificationObjects" : {
2216
+ "nodetype" : "column",
2217
+ "moduleName" : "DISMAN-EVENT-MIB",
2218
+ "oid" : "1.3.6.1.2.1.88.1.4.3.1.3",
2219
+ "status" : "current",
2220
+ "syntax" : {
2221
+ "type" : {
2222
+ "basetype" : "OctetString",
2223
+ "parent module" : {
2224
+ "name" : "SNMP-FRAMEWORK-MIB",
2225
+ "type" : "SnmpAdminString",
2226
+ },
2227
+ "ranges" : [
2228
+ {
2229
+ "min" : "0",
2230
+ "max" : "32"
2231
+ },
2232
+ ],
2233
+ "range" : {
2234
+ "min" : "0",
2235
+ "max" : "32"
2236
+ },
2237
+ },
2238
+ },
2239
+ "access" : "readwrite",
2240
+ "default" : "",
2241
+ "description" :
2242
+ """The mteObjectsName of a group of objects from
2243
+ mteObjectsTable if mteEventActions has 'notification' set.
2244
+ These objects are to be added to any Notification generated by
2245
+ this event.
2246
+
2247
+ Objects may also be added based on the trigger that stimulated
2248
+ the event.
2249
+
2250
+ A length of 0 indicates no additional objects.""",
2251
+ }, # column
2252
+ "mteEventSetTable" : {
2253
+ "nodetype" : "table",
2254
+ "moduleName" : "DISMAN-EVENT-MIB",
2255
+ "oid" : "1.3.6.1.2.1.88.1.4.4",
2256
+ "status" : "current",
2257
+ "description" :
2258
+ """A table of management event action information.""",
2259
+ }, # table
2260
+ "mteEventSetEntry" : {
2261
+ "nodetype" : "row",
2262
+ "moduleName" : "DISMAN-EVENT-MIB",
2263
+ "oid" : "1.3.6.1.2.1.88.1.4.4.1",
2264
+ "status" : "current",
2265
+ "implied" : "true",
2266
+ "linkage" : [
2267
+ "mteOwner",
2268
+ "mteEventName",
2269
+ ],
2270
+ "description" :
2271
+ """Information about a single event's set option. Entries
2272
+ automatically exist in this this table for each mteEventEntry
2273
+ that has 'set' set in mteEventActions.""",
2274
+ }, # row
2275
+ "mteEventSetObject" : {
2276
+ "nodetype" : "column",
2277
+ "moduleName" : "DISMAN-EVENT-MIB",
2278
+ "oid" : "1.3.6.1.2.1.88.1.4.4.1.1",
2279
+ "status" : "current",
2280
+ "syntax" : {
2281
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
2282
+ },
2283
+ "access" : "readwrite",
2284
+ "default" : "0.0",
2285
+ "description" :
2286
+ """The object identifier from the MIB object to set if
2287
+ mteEventActions has 'set' set.
2288
+
2289
+ This object identifier may be wildcarded by leaving
2290
+ sub-identifiers off the end, in which case
2291
+ nteEventSetObjectWildCard must be 'true'.
2292
+
2293
+ If mteEventSetObject is wildcarded the instance used to set the
2294
+ object to which it points is the same as the instance from the
2295
+ value of mteTriggerValueID that triggered the event.
2296
+
2297
+ Each instance that fills the wildcard is independent of any
2298
+ additional instances, that is, wildcarded objects operate
2299
+ as if there were a separate table entry for each instance
2300
+ that fills the wildcard without having to actually predict
2301
+ all possible instances ahead of time.
2302
+
2303
+ Bad object identifiers or a mismatch between truncating the
2304
+ identifier and the value of mteSetObjectWildcard
2305
+ result in operation as one would expect when providing the
2306
+ wrong identifier to a Set operation. The Set will fail or set
2307
+ the wrong object. If the value syntax of the destination
2308
+ object is not correct, the Set fails with the normal SNMP
2309
+ error code.""",
2310
+ }, # column
2311
+ "mteEventSetObjectWildcard" : {
2312
+ "nodetype" : "column",
2313
+ "moduleName" : "DISMAN-EVENT-MIB",
2314
+ "oid" : "1.3.6.1.2.1.88.1.4.4.1.2",
2315
+ "status" : "current",
2316
+ "syntax" : {
2317
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
2318
+ },
2319
+ "access" : "readwrite",
2320
+ "default" : "false",
2321
+ "description" :
2322
+ """Control over whether mteEventSetObject is to be treated as
2323
+ fully-specified or wildcarded, with 'true' indicating wildcard
2324
+ if mteEventActions has 'set' set.""",
2325
+ }, # column
2326
+ "mteEventSetValue" : {
2327
+ "nodetype" : "column",
2328
+ "moduleName" : "DISMAN-EVENT-MIB",
2329
+ "oid" : "1.3.6.1.2.1.88.1.4.4.1.3",
2330
+ "status" : "current",
2331
+ "syntax" : {
2332
+ "type" : { "module" :"", "name" : "Integer32"},
2333
+ },
2334
+ "access" : "readwrite",
2335
+ "default" : "0",
2336
+ "description" :
2337
+ """The value to which to set the object at mteEventSetObject
2338
+ if mteEventActions has 'set' set.""",
2339
+ }, # column
2340
+ "mteEventSetTargetTag" : {
2341
+ "nodetype" : "column",
2342
+ "moduleName" : "DISMAN-EVENT-MIB",
2343
+ "oid" : "1.3.6.1.2.1.88.1.4.4.1.4",
2344
+ "status" : "current",
2345
+ "syntax" : {
2346
+ "type" : { "module" :"SNMP-TARGET-MIB", "name" : "SnmpTagValue"},
2347
+ },
2348
+ "access" : "readwrite",
2349
+ "default" : "",
2350
+ "description" :
2351
+ """The tag for the target(s) at which to set the object at
2352
+ mteEventSetObject to mteEventSetValue if mteEventActions
2353
+ has 'set' set.
2354
+
2355
+ Systems limited to self management MAY reject a non-zero
2356
+ length for the value of this object.
2357
+
2358
+ A length of 0 indicates the local system. In this case,
2359
+ access to the objects indicated by mteEventSetObject is under
2360
+ the security credentials of the requester that set
2361
+ mteTriggerEntryStatus to 'active'. Those credentials are the
2362
+ input parameters for isAccessAllowed from the Architecture for
2363
+ Describing SNMP Management Frameworks.
2364
+
2365
+ Otherwise access rights are checked according to the security
2366
+ parameters resulting from the tag.""",
2367
+ }, # column
2368
+ "mteEventSetContextName" : {
2369
+ "nodetype" : "column",
2370
+ "moduleName" : "DISMAN-EVENT-MIB",
2371
+ "oid" : "1.3.6.1.2.1.88.1.4.4.1.5",
2372
+ "status" : "current",
2373
+ "syntax" : {
2374
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
2375
+ },
2376
+ "access" : "readwrite",
2377
+ "default" : "",
2378
+ "description" :
2379
+ """The management context in which to set mteEventObjectID.
2380
+ if mteEventActions has 'set' set.
2381
+
2382
+ This may be wildcarded by leaving characters off the end. To
2383
+ indicate such wildcarding mteEventSetContextNameWildcard must
2384
+ be 'true'.
2385
+
2386
+ If this context name is wildcarded the value used to complete
2387
+ the wildcarding of mteTriggerContextName will be appended.""",
2388
+ }, # column
2389
+ "mteEventSetContextNameWildcard" : {
2390
+ "nodetype" : "column",
2391
+ "moduleName" : "DISMAN-EVENT-MIB",
2392
+ "oid" : "1.3.6.1.2.1.88.1.4.4.1.6",
2393
+ "status" : "current",
2394
+ "syntax" : {
2395
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
2396
+ },
2397
+ "access" : "readwrite",
2398
+ "default" : "false",
2399
+ "description" :
2400
+ """Control for whether mteEventSetContextName is to be treated as
2401
+ fully-specified or wildcarded, with 'true' indicating wildcard
2402
+ if mteEventActions has 'set' set.""",
2403
+ }, # column
2404
+ "dismanEventMIBNotificationPrefix" : {
2405
+ "nodetype" : "node",
2406
+ "moduleName" : "DISMAN-EVENT-MIB",
2407
+ "oid" : "1.3.6.1.2.1.88.2",
2408
+ }, # node
2409
+ "dismanEventMIBNotifications" : {
2410
+ "nodetype" : "node",
2411
+ "moduleName" : "DISMAN-EVENT-MIB",
2412
+ "oid" : "1.3.6.1.2.1.88.2.0",
2413
+ }, # node
2414
+ "dismanEventMIBNotificationObjects" : {
2415
+ "nodetype" : "node",
2416
+ "moduleName" : "DISMAN-EVENT-MIB",
2417
+ "oid" : "1.3.6.1.2.1.88.2.1",
2418
+ }, # node
2419
+ "mteHotTrigger" : {
2420
+ "nodetype" : "scalar",
2421
+ "moduleName" : "DISMAN-EVENT-MIB",
2422
+ "oid" : "1.3.6.1.2.1.88.2.1.1",
2423
+ "status" : "current",
2424
+ "syntax" : {
2425
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
2426
+ },
2427
+ "access" : "notifyonly",
2428
+ "description" :
2429
+ """The name of the trigger causing the notification.""",
2430
+ }, # scalar
2431
+ "mteHotTargetName" : {
2432
+ "nodetype" : "scalar",
2433
+ "moduleName" : "DISMAN-EVENT-MIB",
2434
+ "oid" : "1.3.6.1.2.1.88.2.1.2",
2435
+ "status" : "current",
2436
+ "syntax" : {
2437
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
2438
+ },
2439
+ "access" : "notifyonly",
2440
+ "description" :
2441
+ """The SNMP Target MIB's snmpTargetAddrName related to the
2442
+ notification.""",
2443
+ }, # scalar
2444
+ "mteHotContextName" : {
2445
+ "nodetype" : "scalar",
2446
+ "moduleName" : "DISMAN-EVENT-MIB",
2447
+ "oid" : "1.3.6.1.2.1.88.2.1.3",
2448
+ "status" : "current",
2449
+ "syntax" : {
2450
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
2451
+ },
2452
+ "access" : "notifyonly",
2453
+ "description" :
2454
+ """The context name related to the notification. This MUST be as
2455
+ fully-qualified as possible, including filling in wildcard
2456
+ information determined in processing.""",
2457
+ }, # scalar
2458
+ "mteHotOID" : {
2459
+ "nodetype" : "scalar",
2460
+ "moduleName" : "DISMAN-EVENT-MIB",
2461
+ "oid" : "1.3.6.1.2.1.88.2.1.4",
2462
+ "status" : "current",
2463
+ "syntax" : {
2464
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
2465
+ },
2466
+ "access" : "notifyonly",
2467
+ "description" :
2468
+ """The object identifier of the destination object related to the
2469
+ notification. This MUST be as fully-qualified as possible,
2470
+ including filling in wildcard information determined in
2471
+ processing.
2472
+
2473
+ For a trigger-related notification this is from
2474
+ mteTriggerValueID.
2475
+
2476
+ For a set failure this is from mteEventSetObject.""",
2477
+ }, # scalar
2478
+ "mteHotValue" : {
2479
+ "nodetype" : "scalar",
2480
+ "moduleName" : "DISMAN-EVENT-MIB",
2481
+ "oid" : "1.3.6.1.2.1.88.2.1.5",
2482
+ "status" : "current",
2483
+ "syntax" : {
2484
+ "type" : { "module" :"", "name" : "Integer32"},
2485
+ },
2486
+ "access" : "notifyonly",
2487
+ "description" :
2488
+ """The value of the object at mteTriggerValueID when a
2489
+ trigger fired.""",
2490
+ }, # scalar
2491
+ "mteFailedReason" : {
2492
+ "nodetype" : "scalar",
2493
+ "moduleName" : "DISMAN-EVENT-MIB",
2494
+ "oid" : "1.3.6.1.2.1.88.2.1.6",
2495
+ "status" : "current",
2496
+ "syntax" : {
2497
+ "type" : { "module" :"DISMAN-EVENT-MIB", "name" : "FailureReason"},
2498
+ },
2499
+ "access" : "notifyonly",
2500
+ "description" :
2501
+ """The reason for the failure of an attempt to check for a
2502
+ trigger condition or set an object in response to an event.""",
2503
+ }, # scalar
2504
+ "dismanEventMIBConformance" : {
2505
+ "nodetype" : "node",
2506
+ "moduleName" : "DISMAN-EVENT-MIB",
2507
+ "oid" : "1.3.6.1.2.1.88.3",
2508
+ }, # node
2509
+ "dismanEventMIBCompliances" : {
2510
+ "nodetype" : "node",
2511
+ "moduleName" : "DISMAN-EVENT-MIB",
2512
+ "oid" : "1.3.6.1.2.1.88.3.1",
2513
+ }, # node
2514
+ "dismanEventMIBGroups" : {
2515
+ "nodetype" : "node",
2516
+ "moduleName" : "DISMAN-EVENT-MIB",
2517
+ "oid" : "1.3.6.1.2.1.88.3.2",
2518
+ }, # node
2519
+ }, # nodes
2520
+
2521
+ "notifications" : {
2522
+ "mteTriggerFired" : {
2523
+ "nodetype" : "notification",
2524
+ "moduleName" : "DISMAN-EVENT-MIB",
2525
+ "oid" : "1.3.6.1.2.1.88.2.0.1",
2526
+ "status" : "current",
2527
+ "objects" : {
2528
+ "mteHotTrigger" : {
2529
+ "nodetype" : "object",
2530
+ "module" : "DISMAN-EVENT-MIB"
2531
+ },
2532
+ "mteHotTargetName" : {
2533
+ "nodetype" : "object",
2534
+ "module" : "DISMAN-EVENT-MIB"
2535
+ },
2536
+ "mteHotContextName" : {
2537
+ "nodetype" : "object",
2538
+ "module" : "DISMAN-EVENT-MIB"
2539
+ },
2540
+ "mteHotOID" : {
2541
+ "nodetype" : "object",
2542
+ "module" : "DISMAN-EVENT-MIB"
2543
+ },
2544
+ "mteHotValue" : {
2545
+ "nodetype" : "object",
2546
+ "module" : "DISMAN-EVENT-MIB"
2547
+ },
2548
+ },
2549
+ "description" :
2550
+ """Notification that the trigger indicated by the object
2551
+ instances has fired, for triggers with mteTriggerType
2552
+ 'boolean' or 'existence'.""",
2553
+ }, # notification
2554
+ "mteTriggerRising" : {
2555
+ "nodetype" : "notification",
2556
+ "moduleName" : "DISMAN-EVENT-MIB",
2557
+ "oid" : "1.3.6.1.2.1.88.2.0.2",
2558
+ "status" : "current",
2559
+ "objects" : {
2560
+ "mteHotTrigger" : {
2561
+ "nodetype" : "object",
2562
+ "module" : "DISMAN-EVENT-MIB"
2563
+ },
2564
+ "mteHotTargetName" : {
2565
+ "nodetype" : "object",
2566
+ "module" : "DISMAN-EVENT-MIB"
2567
+ },
2568
+ "mteHotContextName" : {
2569
+ "nodetype" : "object",
2570
+ "module" : "DISMAN-EVENT-MIB"
2571
+ },
2572
+ "mteHotOID" : {
2573
+ "nodetype" : "object",
2574
+ "module" : "DISMAN-EVENT-MIB"
2575
+ },
2576
+ "mteHotValue" : {
2577
+ "nodetype" : "object",
2578
+ "module" : "DISMAN-EVENT-MIB"
2579
+ },
2580
+ },
2581
+ "description" :
2582
+ """Notification that the rising threshold was met for triggers
2583
+ with mteTriggerType 'threshold'.""",
2584
+ }, # notification
2585
+ "mteTriggerFalling" : {
2586
+ "nodetype" : "notification",
2587
+ "moduleName" : "DISMAN-EVENT-MIB",
2588
+ "oid" : "1.3.6.1.2.1.88.2.0.3",
2589
+ "status" : "current",
2590
+ "objects" : {
2591
+ "mteHotTrigger" : {
2592
+ "nodetype" : "object",
2593
+ "module" : "DISMAN-EVENT-MIB"
2594
+ },
2595
+ "mteHotTargetName" : {
2596
+ "nodetype" : "object",
2597
+ "module" : "DISMAN-EVENT-MIB"
2598
+ },
2599
+ "mteHotContextName" : {
2600
+ "nodetype" : "object",
2601
+ "module" : "DISMAN-EVENT-MIB"
2602
+ },
2603
+ "mteHotOID" : {
2604
+ "nodetype" : "object",
2605
+ "module" : "DISMAN-EVENT-MIB"
2606
+ },
2607
+ "mteHotValue" : {
2608
+ "nodetype" : "object",
2609
+ "module" : "DISMAN-EVENT-MIB"
2610
+ },
2611
+ },
2612
+ "description" :
2613
+ """Notification that the falling threshold was met for triggers
2614
+ with mteTriggerType 'threshold'.""",
2615
+ }, # notification
2616
+ "mteTriggerFailure" : {
2617
+ "nodetype" : "notification",
2618
+ "moduleName" : "DISMAN-EVENT-MIB",
2619
+ "oid" : "1.3.6.1.2.1.88.2.0.4",
2620
+ "status" : "current",
2621
+ "objects" : {
2622
+ "mteHotTrigger" : {
2623
+ "nodetype" : "object",
2624
+ "module" : "DISMAN-EVENT-MIB"
2625
+ },
2626
+ "mteHotTargetName" : {
2627
+ "nodetype" : "object",
2628
+ "module" : "DISMAN-EVENT-MIB"
2629
+ },
2630
+ "mteHotContextName" : {
2631
+ "nodetype" : "object",
2632
+ "module" : "DISMAN-EVENT-MIB"
2633
+ },
2634
+ "mteHotOID" : {
2635
+ "nodetype" : "object",
2636
+ "module" : "DISMAN-EVENT-MIB"
2637
+ },
2638
+ "mteFailedReason" : {
2639
+ "nodetype" : "object",
2640
+ "module" : "DISMAN-EVENT-MIB"
2641
+ },
2642
+ },
2643
+ "description" :
2644
+ """Notification that an attempt to check a trigger has failed.
2645
+
2646
+ The network manager must enable this notification only with
2647
+ a certain fear and trembling, as it can easily crowd out more
2648
+ important information. It should be used only to help diagnose
2649
+ a problem that has appeared in the error counters and can not
2650
+ be found otherwise.""",
2651
+ }, # notification
2652
+ "mteEventSetFailure" : {
2653
+ "nodetype" : "notification",
2654
+ "moduleName" : "DISMAN-EVENT-MIB",
2655
+ "oid" : "1.3.6.1.2.1.88.2.0.5",
2656
+ "status" : "current",
2657
+ "objects" : {
2658
+ "mteHotTrigger" : {
2659
+ "nodetype" : "object",
2660
+ "module" : "DISMAN-EVENT-MIB"
2661
+ },
2662
+ "mteHotTargetName" : {
2663
+ "nodetype" : "object",
2664
+ "module" : "DISMAN-EVENT-MIB"
2665
+ },
2666
+ "mteHotContextName" : {
2667
+ "nodetype" : "object",
2668
+ "module" : "DISMAN-EVENT-MIB"
2669
+ },
2670
+ "mteHotOID" : {
2671
+ "nodetype" : "object",
2672
+ "module" : "DISMAN-EVENT-MIB"
2673
+ },
2674
+ "mteFailedReason" : {
2675
+ "nodetype" : "object",
2676
+ "module" : "DISMAN-EVENT-MIB"
2677
+ },
2678
+ },
2679
+ "description" :
2680
+ """Notification that an attempt to do a set in response to an
2681
+ event has failed.
2682
+
2683
+ The network manager must enable this notification only with
2684
+ a certain fear and trembling, as it can easily crowd out more
2685
+ important information. It should be used only to help diagnose
2686
+ a problem that has appeared in the error counters and can not
2687
+ be found otherwise.""",
2688
+ }, # notification
2689
+ }, # notifications
2690
+
2691
+ "groups" : {
2692
+ "dismanEventResourceGroup" : {
2693
+ "nodetype" : "group",
2694
+ "moduleName" : "DISMAN-EVENT-MIB",
2695
+ "oid" : "1.3.6.1.2.1.88.3.2.1",
2696
+ "status" : "current",
2697
+ "members" : {
2698
+ "mteResourceSampleMinimum" : {
2699
+ "nodetype" : "member",
2700
+ "module" : "DISMAN-EVENT-MIB"
2701
+ },
2702
+ "mteResourceSampleInstanceMaximum" : {
2703
+ "nodetype" : "member",
2704
+ "module" : "DISMAN-EVENT-MIB"
2705
+ },
2706
+ "mteResourceSampleInstances" : {
2707
+ "nodetype" : "member",
2708
+ "module" : "DISMAN-EVENT-MIB"
2709
+ },
2710
+ "mteResourceSampleInstancesHigh" : {
2711
+ "nodetype" : "member",
2712
+ "module" : "DISMAN-EVENT-MIB"
2713
+ },
2714
+ "mteResourceSampleInstanceLacks" : {
2715
+ "nodetype" : "member",
2716
+ "module" : "DISMAN-EVENT-MIB"
2717
+ },
2718
+ }, # members
2719
+ "description" :
2720
+ """Event resource status and control objects.""",
2721
+ }, # group
2722
+ "dismanEventTriggerGroup" : {
2723
+ "nodetype" : "group",
2724
+ "moduleName" : "DISMAN-EVENT-MIB",
2725
+ "oid" : "1.3.6.1.2.1.88.3.2.2",
2726
+ "status" : "current",
2727
+ "members" : {
2728
+ "mteTriggerFailures" : {
2729
+ "nodetype" : "member",
2730
+ "module" : "DISMAN-EVENT-MIB"
2731
+ },
2732
+ "mteTriggerComment" : {
2733
+ "nodetype" : "member",
2734
+ "module" : "DISMAN-EVENT-MIB"
2735
+ },
2736
+ "mteTriggerTest" : {
2737
+ "nodetype" : "member",
2738
+ "module" : "DISMAN-EVENT-MIB"
2739
+ },
2740
+ "mteTriggerSampleType" : {
2741
+ "nodetype" : "member",
2742
+ "module" : "DISMAN-EVENT-MIB"
2743
+ },
2744
+ "mteTriggerValueID" : {
2745
+ "nodetype" : "member",
2746
+ "module" : "DISMAN-EVENT-MIB"
2747
+ },
2748
+ "mteTriggerValueIDWildcard" : {
2749
+ "nodetype" : "member",
2750
+ "module" : "DISMAN-EVENT-MIB"
2751
+ },
2752
+ "mteTriggerTargetTag" : {
2753
+ "nodetype" : "member",
2754
+ "module" : "DISMAN-EVENT-MIB"
2755
+ },
2756
+ "mteTriggerContextName" : {
2757
+ "nodetype" : "member",
2758
+ "module" : "DISMAN-EVENT-MIB"
2759
+ },
2760
+ "mteTriggerContextNameWildcard" : {
2761
+ "nodetype" : "member",
2762
+ "module" : "DISMAN-EVENT-MIB"
2763
+ },
2764
+ "mteTriggerFrequency" : {
2765
+ "nodetype" : "member",
2766
+ "module" : "DISMAN-EVENT-MIB"
2767
+ },
2768
+ "mteTriggerObjectsOwner" : {
2769
+ "nodetype" : "member",
2770
+ "module" : "DISMAN-EVENT-MIB"
2771
+ },
2772
+ "mteTriggerObjects" : {
2773
+ "nodetype" : "member",
2774
+ "module" : "DISMAN-EVENT-MIB"
2775
+ },
2776
+ "mteTriggerEnabled" : {
2777
+ "nodetype" : "member",
2778
+ "module" : "DISMAN-EVENT-MIB"
2779
+ },
2780
+ "mteTriggerEntryStatus" : {
2781
+ "nodetype" : "member",
2782
+ "module" : "DISMAN-EVENT-MIB"
2783
+ },
2784
+ "mteTriggerDeltaDiscontinuityID" : {
2785
+ "nodetype" : "member",
2786
+ "module" : "DISMAN-EVENT-MIB"
2787
+ },
2788
+ "mteTriggerDeltaDiscontinuityIDWildcard" : {
2789
+ "nodetype" : "member",
2790
+ "module" : "DISMAN-EVENT-MIB"
2791
+ },
2792
+ "mteTriggerDeltaDiscontinuityIDType" : {
2793
+ "nodetype" : "member",
2794
+ "module" : "DISMAN-EVENT-MIB"
2795
+ },
2796
+ "mteTriggerExistenceTest" : {
2797
+ "nodetype" : "member",
2798
+ "module" : "DISMAN-EVENT-MIB"
2799
+ },
2800
+ "mteTriggerExistenceStartup" : {
2801
+ "nodetype" : "member",
2802
+ "module" : "DISMAN-EVENT-MIB"
2803
+ },
2804
+ "mteTriggerExistenceObjectsOwner" : {
2805
+ "nodetype" : "member",
2806
+ "module" : "DISMAN-EVENT-MIB"
2807
+ },
2808
+ "mteTriggerExistenceObjects" : {
2809
+ "nodetype" : "member",
2810
+ "module" : "DISMAN-EVENT-MIB"
2811
+ },
2812
+ "mteTriggerExistenceEventOwner" : {
2813
+ "nodetype" : "member",
2814
+ "module" : "DISMAN-EVENT-MIB"
2815
+ },
2816
+ "mteTriggerExistenceEvent" : {
2817
+ "nodetype" : "member",
2818
+ "module" : "DISMAN-EVENT-MIB"
2819
+ },
2820
+ "mteTriggerBooleanComparison" : {
2821
+ "nodetype" : "member",
2822
+ "module" : "DISMAN-EVENT-MIB"
2823
+ },
2824
+ "mteTriggerBooleanValue" : {
2825
+ "nodetype" : "member",
2826
+ "module" : "DISMAN-EVENT-MIB"
2827
+ },
2828
+ "mteTriggerBooleanStartup" : {
2829
+ "nodetype" : "member",
2830
+ "module" : "DISMAN-EVENT-MIB"
2831
+ },
2832
+ "mteTriggerBooleanObjectsOwner" : {
2833
+ "nodetype" : "member",
2834
+ "module" : "DISMAN-EVENT-MIB"
2835
+ },
2836
+ "mteTriggerBooleanObjects" : {
2837
+ "nodetype" : "member",
2838
+ "module" : "DISMAN-EVENT-MIB"
2839
+ },
2840
+ "mteTriggerBooleanEventOwner" : {
2841
+ "nodetype" : "member",
2842
+ "module" : "DISMAN-EVENT-MIB"
2843
+ },
2844
+ "mteTriggerBooleanEvent" : {
2845
+ "nodetype" : "member",
2846
+ "module" : "DISMAN-EVENT-MIB"
2847
+ },
2848
+ "mteTriggerThresholdStartup" : {
2849
+ "nodetype" : "member",
2850
+ "module" : "DISMAN-EVENT-MIB"
2851
+ },
2852
+ "mteTriggerThresholdObjectsOwner" : {
2853
+ "nodetype" : "member",
2854
+ "module" : "DISMAN-EVENT-MIB"
2855
+ },
2856
+ "mteTriggerThresholdObjects" : {
2857
+ "nodetype" : "member",
2858
+ "module" : "DISMAN-EVENT-MIB"
2859
+ },
2860
+ "mteTriggerThresholdRising" : {
2861
+ "nodetype" : "member",
2862
+ "module" : "DISMAN-EVENT-MIB"
2863
+ },
2864
+ "mteTriggerThresholdFalling" : {
2865
+ "nodetype" : "member",
2866
+ "module" : "DISMAN-EVENT-MIB"
2867
+ },
2868
+ "mteTriggerThresholdDeltaRising" : {
2869
+ "nodetype" : "member",
2870
+ "module" : "DISMAN-EVENT-MIB"
2871
+ },
2872
+ "mteTriggerThresholdDeltaFalling" : {
2873
+ "nodetype" : "member",
2874
+ "module" : "DISMAN-EVENT-MIB"
2875
+ },
2876
+ "mteTriggerThresholdRisingEventOwner" : {
2877
+ "nodetype" : "member",
2878
+ "module" : "DISMAN-EVENT-MIB"
2879
+ },
2880
+ "mteTriggerThresholdRisingEvent" : {
2881
+ "nodetype" : "member",
2882
+ "module" : "DISMAN-EVENT-MIB"
2883
+ },
2884
+ "mteTriggerThresholdFallingEventOwner" : {
2885
+ "nodetype" : "member",
2886
+ "module" : "DISMAN-EVENT-MIB"
2887
+ },
2888
+ "mteTriggerThresholdFallingEvent" : {
2889
+ "nodetype" : "member",
2890
+ "module" : "DISMAN-EVENT-MIB"
2891
+ },
2892
+ "mteTriggerThresholdDeltaRisingEventOwner" : {
2893
+ "nodetype" : "member",
2894
+ "module" : "DISMAN-EVENT-MIB"
2895
+ },
2896
+ "mteTriggerThresholdDeltaRisingEvent" : {
2897
+ "nodetype" : "member",
2898
+ "module" : "DISMAN-EVENT-MIB"
2899
+ },
2900
+ "mteTriggerThresholdDeltaFallingEventOwner" : {
2901
+ "nodetype" : "member",
2902
+ "module" : "DISMAN-EVENT-MIB"
2903
+ },
2904
+ "mteTriggerThresholdDeltaFallingEvent" : {
2905
+ "nodetype" : "member",
2906
+ "module" : "DISMAN-EVENT-MIB"
2907
+ },
2908
+ }, # members
2909
+ "description" :
2910
+ """Event triggers.""",
2911
+ }, # group
2912
+ "dismanEventObjectsGroup" : {
2913
+ "nodetype" : "group",
2914
+ "moduleName" : "DISMAN-EVENT-MIB",
2915
+ "oid" : "1.3.6.1.2.1.88.3.2.3",
2916
+ "status" : "current",
2917
+ "members" : {
2918
+ "mteObjectsID" : {
2919
+ "nodetype" : "member",
2920
+ "module" : "DISMAN-EVENT-MIB"
2921
+ },
2922
+ "mteObjectsIDWildcard" : {
2923
+ "nodetype" : "member",
2924
+ "module" : "DISMAN-EVENT-MIB"
2925
+ },
2926
+ "mteObjectsEntryStatus" : {
2927
+ "nodetype" : "member",
2928
+ "module" : "DISMAN-EVENT-MIB"
2929
+ },
2930
+ }, # members
2931
+ "description" :
2932
+ """Supplemental objects.""",
2933
+ }, # group
2934
+ "dismanEventEventGroup" : {
2935
+ "nodetype" : "group",
2936
+ "moduleName" : "DISMAN-EVENT-MIB",
2937
+ "oid" : "1.3.6.1.2.1.88.3.2.4",
2938
+ "status" : "current",
2939
+ "members" : {
2940
+ "mteEventFailures" : {
2941
+ "nodetype" : "member",
2942
+ "module" : "DISMAN-EVENT-MIB"
2943
+ },
2944
+ "mteEventComment" : {
2945
+ "nodetype" : "member",
2946
+ "module" : "DISMAN-EVENT-MIB"
2947
+ },
2948
+ "mteEventActions" : {
2949
+ "nodetype" : "member",
2950
+ "module" : "DISMAN-EVENT-MIB"
2951
+ },
2952
+ "mteEventEnabled" : {
2953
+ "nodetype" : "member",
2954
+ "module" : "DISMAN-EVENT-MIB"
2955
+ },
2956
+ "mteEventEntryStatus" : {
2957
+ "nodetype" : "member",
2958
+ "module" : "DISMAN-EVENT-MIB"
2959
+ },
2960
+ "mteEventNotification" : {
2961
+ "nodetype" : "member",
2962
+ "module" : "DISMAN-EVENT-MIB"
2963
+ },
2964
+ "mteEventNotificationObjectsOwner" : {
2965
+ "nodetype" : "member",
2966
+ "module" : "DISMAN-EVENT-MIB"
2967
+ },
2968
+ "mteEventNotificationObjects" : {
2969
+ "nodetype" : "member",
2970
+ "module" : "DISMAN-EVENT-MIB"
2971
+ },
2972
+ "mteEventSetObject" : {
2973
+ "nodetype" : "member",
2974
+ "module" : "DISMAN-EVENT-MIB"
2975
+ },
2976
+ "mteEventSetObjectWildcard" : {
2977
+ "nodetype" : "member",
2978
+ "module" : "DISMAN-EVENT-MIB"
2979
+ },
2980
+ "mteEventSetValue" : {
2981
+ "nodetype" : "member",
2982
+ "module" : "DISMAN-EVENT-MIB"
2983
+ },
2984
+ "mteEventSetTargetTag" : {
2985
+ "nodetype" : "member",
2986
+ "module" : "DISMAN-EVENT-MIB"
2987
+ },
2988
+ "mteEventSetContextName" : {
2989
+ "nodetype" : "member",
2990
+ "module" : "DISMAN-EVENT-MIB"
2991
+ },
2992
+ "mteEventSetContextNameWildcard" : {
2993
+ "nodetype" : "member",
2994
+ "module" : "DISMAN-EVENT-MIB"
2995
+ },
2996
+ }, # members
2997
+ "description" :
2998
+ """Events.""",
2999
+ }, # group
3000
+ "dismanEventNotificationObjectGroup" : {
3001
+ "nodetype" : "group",
3002
+ "moduleName" : "DISMAN-EVENT-MIB",
3003
+ "oid" : "1.3.6.1.2.1.88.3.2.5",
3004
+ "status" : "current",
3005
+ "members" : {
3006
+ "mteHotTrigger" : {
3007
+ "nodetype" : "member",
3008
+ "module" : "DISMAN-EVENT-MIB"
3009
+ },
3010
+ "mteHotTargetName" : {
3011
+ "nodetype" : "member",
3012
+ "module" : "DISMAN-EVENT-MIB"
3013
+ },
3014
+ "mteHotContextName" : {
3015
+ "nodetype" : "member",
3016
+ "module" : "DISMAN-EVENT-MIB"
3017
+ },
3018
+ "mteHotOID" : {
3019
+ "nodetype" : "member",
3020
+ "module" : "DISMAN-EVENT-MIB"
3021
+ },
3022
+ "mteHotValue" : {
3023
+ "nodetype" : "member",
3024
+ "module" : "DISMAN-EVENT-MIB"
3025
+ },
3026
+ "mteFailedReason" : {
3027
+ "nodetype" : "member",
3028
+ "module" : "DISMAN-EVENT-MIB"
3029
+ },
3030
+ }, # members
3031
+ "description" :
3032
+ """Notification objects.""",
3033
+ }, # group
3034
+ "dismanEventNotificationGroup" : {
3035
+ "nodetype" : "group",
3036
+ "moduleName" : "DISMAN-EVENT-MIB",
3037
+ "oid" : "1.3.6.1.2.1.88.3.2.6",
3038
+ "status" : "current",
3039
+ "members" : {
3040
+ "mteTriggerFired" : {
3041
+ "nodetype" : "member",
3042
+ "module" : "DISMAN-EVENT-MIB"
3043
+ },
3044
+ "mteTriggerRising" : {
3045
+ "nodetype" : "member",
3046
+ "module" : "DISMAN-EVENT-MIB"
3047
+ },
3048
+ "mteTriggerFalling" : {
3049
+ "nodetype" : "member",
3050
+ "module" : "DISMAN-EVENT-MIB"
3051
+ },
3052
+ "mteTriggerFailure" : {
3053
+ "nodetype" : "member",
3054
+ "module" : "DISMAN-EVENT-MIB"
3055
+ },
3056
+ "mteEventSetFailure" : {
3057
+ "nodetype" : "member",
3058
+ "module" : "DISMAN-EVENT-MIB"
3059
+ },
3060
+ }, # members
3061
+ "description" :
3062
+ """Notifications.""",
3063
+ }, # group
3064
+ }, # groups
3065
+
3066
+ "compliances" : {
3067
+ "dismanEventMIBCompliance" : {
3068
+ "nodetype" : "compliance",
3069
+ "moduleName" : "DISMAN-EVENT-MIB",
3070
+ "oid" : "1.3.6.1.2.1.88.3.1.1",
3071
+ "status" : "current",
3072
+ "description" :
3073
+ """The compliance statement for entities which implement
3074
+ the Event MIB.""",
3075
+ "requires" : {
3076
+ "dismanEventResourceGroup" : {
3077
+ "nodetype" : "mandatory",
3078
+ "module" : "DISMAN-EVENT-MIB"
3079
+ },
3080
+ "dismanEventTriggerGroup" : {
3081
+ "nodetype" : "mandatory",
3082
+ "module" : "DISMAN-EVENT-MIB"
3083
+ },
3084
+ "dismanEventObjectsGroup" : {
3085
+ "nodetype" : "mandatory",
3086
+ "module" : "DISMAN-EVENT-MIB"
3087
+ },
3088
+ "dismanEventEventGroup" : {
3089
+ "nodetype" : "mandatory",
3090
+ "module" : "DISMAN-EVENT-MIB"
3091
+ },
3092
+ "dismanEventNotificationObjectGroup" : {
3093
+ "nodetype" : "mandatory",
3094
+ "module" : "DISMAN-EVENT-MIB"
3095
+ },
3096
+ "dismanEventNotificationGroup" : {
3097
+ "nodetype" : "mandatory",
3098
+ "module" : "DISMAN-EVENT-MIB"
3099
+ },
3100
+ }, # requires
3101
+ "refinements" : {
3102
+ "mteTriggerTargetTag" : {
3103
+ "module" : "DISMAN-EVENT-MIB",
3104
+ "access" : "readonly",
3105
+ "description" :
3106
+ """Write access is not required, thus limiting
3107
+ monitoring to the local system or pre-configured
3108
+ remote systems.""",
3109
+ },
3110
+ "mteEventSetTargetTag" : {
3111
+ "module" : "DISMAN-EVENT-MIB",
3112
+ "access" : "readonly",
3113
+ "description" :
3114
+ """Write access is not required, thus limiting
3115
+ setting to the local system or pre-configured
3116
+ remote systems.""",
3117
+ },
3118
+ "mteTriggerValueIDWildcard" : {
3119
+ "module" : "DISMAN-EVENT-MIB",
3120
+ "access" : "readonly",
3121
+ "description" :
3122
+ """Write access is not required, thus allowing
3123
+ the system not to implement wildcarding.""",
3124
+ },
3125
+ "mteTriggerContextNameWildcard" : {
3126
+ "module" : "DISMAN-EVENT-MIB",
3127
+ "access" : "readonly",
3128
+ "description" :
3129
+ """Write access is not required, thus allowing
3130
+ the system not to implement wildcarding.""",
3131
+ },
3132
+ "mteObjectsIDWildcard" : {
3133
+ "module" : "DISMAN-EVENT-MIB",
3134
+ "access" : "readonly",
3135
+ "description" :
3136
+ """Write access is not required, thus allowing
3137
+ the system not to implement wildcarding.""",
3138
+ },
3139
+ "mteEventSetContextNameWildcard" : {
3140
+ "module" : "DISMAN-EVENT-MIB",
3141
+ "access" : "readonly",
3142
+ "description" :
3143
+ """Write access is not required, thus allowing
3144
+ the system not to implement wildcarding.""",
3145
+ },
3146
+ }, # refinements
3147
+
3148
+ }, # compliance
3149
+ }, # compliances
3150
+
3151
+ }