logstash-integration-snmp 4.0.0-java

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (324) hide show
  1. checksums.yaml +7 -0
  2. data/CHANGELOG.md +23 -0
  3. data/CONTRIBUTORS +20 -0
  4. data/Gemfile +11 -0
  5. data/LICENSE +202 -0
  6. data/README.md +89 -0
  7. data/VERSION +1 -0
  8. data/docs/index.asciidoc +202 -0
  9. data/docs/input-snmp.asciidoc +524 -0
  10. data/docs/input-snmptrap.asciidoc +392 -0
  11. data/lib/logstash/inputs/snmp.rb +369 -0
  12. data/lib/logstash/inputs/snmptrap.rb +190 -0
  13. data/lib/logstash/plugin_mixins/snmp/common.rb +197 -0
  14. data/lib/logstash-integration-snmp_jars.rb +6 -0
  15. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  16. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  17. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  18. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  19. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  20. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  21. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  22. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  23. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  24. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  25. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  26. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  27. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  28. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  29. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  30. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  31. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  32. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  33. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  34. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  35. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  36. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  37. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  38. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  39. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  40. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  41. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  42. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  43. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  44. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  45. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  46. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  47. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  48. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  49. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  50. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  51. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  52. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  53. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  54. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  55. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  56. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  57. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  58. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  59. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  60. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  61. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  62. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  63. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  64. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  65. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  66. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  67. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  68. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  69. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  70. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  71. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  72. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  73. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  74. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  75. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  76. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  77. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  78. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  79. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  80. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  81. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  82. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  83. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  84. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  85. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  86. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  87. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  88. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  89. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  90. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  91. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  92. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  93. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  94. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  95. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  96. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  97. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  98. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  99. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  100. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  101. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  102. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  103. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  104. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  105. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  106. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  107. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  108. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  109. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  110. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  111. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  112. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  113. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  114. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  115. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  116. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  117. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  118. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  119. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  120. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  121. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  122. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  123. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  124. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  125. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  126. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  127. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  128. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  129. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  130. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  131. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  132. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  133. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  134. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  135. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  136. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  137. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  138. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  139. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  140. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  141. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  142. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  143. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  144. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  145. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  146. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  147. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  148. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  149. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  150. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  151. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  152. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  153. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  154. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  155. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  156. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  157. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  158. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  159. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  160. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  161. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  162. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  163. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  164. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  165. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  166. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  167. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  168. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  169. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  170. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  171. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  172. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  173. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  174. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  175. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  176. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  177. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  178. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  179. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  180. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  181. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  182. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  183. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  184. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  185. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  186. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  187. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  188. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  189. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  190. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  191. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  192. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  193. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  194. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  195. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  196. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  197. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  198. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  199. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  200. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  201. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  202. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  203. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  204. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  205. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  206. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  207. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  208. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  209. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  210. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  211. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  212. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  213. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  214. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  215. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  216. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  217. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  218. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  219. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  220. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  221. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  222. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  223. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  224. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  225. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  226. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  227. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  228. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  229. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  230. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  231. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  232. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  233. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  234. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  235. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  236. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  237. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  238. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  239. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  240. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  241. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  242. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  243. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  244. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  245. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  246. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  247. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  248. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  249. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  250. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  251. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  252. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  253. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  254. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  255. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  256. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  257. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  258. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  259. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  260. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  261. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  262. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  263. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  264. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  265. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  266. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  267. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  268. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  269. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  270. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  271. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  272. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  273. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  274. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  275. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  276. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  277. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  278. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  279. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  280. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  281. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  282. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  283. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  284. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  285. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  286. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  287. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  288. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  289. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  290. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  291. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  292. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  293. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  294. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  295. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  296. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  297. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  298. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  299. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  300. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  301. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  302. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  303. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  304. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  305. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  306. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  307. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  308. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  309. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  310. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  311. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  312. data/lib/mibs/logstash/iso.dic +18 -0
  313. data/logstash-integration-snmp.gemspec +40 -0
  314. data/spec/fixtures/RFC1213-MIB.dic +3445 -0
  315. data/spec/fixtures/collision.dic +25 -0
  316. data/spec/integration/inputs/snmp_spec.rb +443 -0
  317. data/spec/integration/inputs/snmptrap_spec.rb +383 -0
  318. data/spec/unit/inputs/common_spec.rb +264 -0
  319. data/spec/unit/inputs/snmp_spec.rb +510 -0
  320. data/spec/unit/inputs/snmptrap_spec.rb +141 -0
  321. data/vendor/jar-dependencies/org/logstash/integrations/plugin/4.0.0/plugin-4.0.0.jar +0 -0
  322. data/vendor/jar-dependencies/org/snakeyaml/snakeyaml-engine/2.7/snakeyaml-engine-2.7.jar +0 -0
  323. data/vendor/jar-dependencies/org/snmp4j/snmp4j/3.8.0/snmp4j-3.8.0.jar +0 -0
  324. metadata +523 -0
@@ -0,0 +1,812 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python BLDG-HVAC-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/BLDG-HVAC-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "BLDG-HVAC-MIB",
11
+
12
+ "BLDG-HVAC-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """SNMPCONF working group
17
+ E-mail: snmpconf@snmp.com""",
18
+ "contact" :
19
+ """Jon Saperia
20
+ Postal: JDS Consulting
21
+ 174 Chapman Street
22
+ Watertown, MA 02472
23
+ U.S.A.
24
+ Phone: +1 617 744 1079
25
+ E-mail: saperia@jdscons.com
26
+
27
+ Wayne Tackabury
28
+ Postal: Gold Wire Technology
29
+ 411 Waverley Oaks Rd.
30
+ Waltham, MA 02452
31
+ U.S.A.
32
+ Phone: +1 781 398 8800
33
+ E-mail: wayne@goldwiretech.com
34
+
35
+
36
+
37
+ Michael MacFaden
38
+ Postal: Riverstone Networks
39
+ 5200 Great America Pkwy.
40
+ Santa Clara, CA 95054
41
+ U.S.A.
42
+ Phone: +1 408 878 6500
43
+ E-mail: mrm@riverstonenet.com
44
+
45
+ David Partain
46
+ Postal: Ericsson AB
47
+ P.O. Box 1248
48
+ SE-581 12 Linkoping
49
+ Sweden
50
+ E-mail: David.Partain@ericsson.com""",
51
+ "description" :
52
+ """This example MIB module defines a set of management objects
53
+ for heating ventilation and air conditioning systems. It
54
+ also includes objects that can be used to create policies
55
+ that are applied to rooms. This eliminates the need to send
56
+ per-instance configuration commands to the system.
57
+
58
+ Copyright (C) The Internet Society (2003). This version of
59
+ this MIB module is part of RFC 3512; see the RFC itself for
60
+ full legal notices.""",
61
+ "revisions" : (
62
+ {
63
+ "date" : "2003-03-27 00:00",
64
+ "description" :
65
+ """Initial version of BLDG-HVAC-MIB as published in RFC 3512.""",
66
+ },
67
+ ),
68
+ "identity node" : "bldgHVACMIB",
69
+ },
70
+
71
+ "imports" : (
72
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
73
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
74
+ {"module" : "SNMPv2-SMI", "name" : "Gauge32"},
75
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
76
+ {"module" : "SNMPv2-SMI", "name" : "Unsigned32"},
77
+ {"module" : "SNMPv2-SMI", "name" : "experimental"},
78
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
79
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
80
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
81
+ {"module" : "SNMPv2-TC", "name" : "TimeStamp"},
82
+ {"module" : "SNMPv2-TC", "name" : "RowStatus"},
83
+ {"module" : "SNMPv2-TC", "name" : "StorageType"},
84
+ {"module" : "SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
85
+ ),
86
+
87
+ "typedefs" : {
88
+ "BldgHvacOperation" : {
89
+ "basetype" : "Enumeration",
90
+ "status" : "current",
91
+ "heat" : {
92
+ "nodetype" : "namednumber",
93
+ "number" : "1"
94
+ },
95
+ "cool" : {
96
+ "nodetype" : "namednumber",
97
+ "number" : "2"
98
+ },
99
+ "description" :
100
+ """Operations supported by a heating and cooling system.
101
+ A reference to underlying general systems would go here.""",
102
+ },
103
+ }, # typedefs
104
+
105
+ "nodes" : {
106
+ "bldgHVACMIB" : {
107
+ "nodetype" : "node",
108
+ "moduleName" : "BLDG-HVAC-MIB",
109
+ "oid" : "1.3.6.1.3.122",
110
+ "status" : "current",
111
+ }, # node
112
+ "bldgHVACObjects" : {
113
+ "nodetype" : "node",
114
+ "moduleName" : "BLDG-HVAC-MIB",
115
+ "oid" : "1.3.6.1.3.122.1",
116
+ }, # node
117
+ "bldgHVACTable" : {
118
+ "nodetype" : "table",
119
+ "moduleName" : "BLDG-HVAC-MIB",
120
+ "oid" : "1.3.6.1.3.122.1.1",
121
+ "status" : "current",
122
+ "description" :
123
+ """This table is the representation and data control
124
+ for building HVAC by each individual office.
125
+ The table has rows for, and is indexed by a specific
126
+ floor and office number. Each such row includes
127
+ HVAC statistical and current status information for
128
+ the associated office. The row also contains a
129
+ bldgHVACCfgTemplate columnar object that relates the
130
+ bldgHVACTable row to a row in the bldgHVACCfgTemplateTable.
131
+ If this value is nonzero, then the instance in the row
132
+ that has a value for how the HVAC has been configured
133
+ in the associated template (bldgHVACCfgTeplateTable row).
134
+ Hence, the bldgHVACCfgTeplateTable row contains the
135
+ specific configuration values for the offices as described
136
+ in this table.""",
137
+ }, # table
138
+ "bldgHVACEntry" : {
139
+ "nodetype" : "row",
140
+ "moduleName" : "BLDG-HVAC-MIB",
141
+ "oid" : "1.3.6.1.3.122.1.1.1",
142
+ "create" : "true",
143
+ "status" : "current",
144
+ "linkage" : [
145
+ "bldgHVACFloor",
146
+ "bldgHVACOffice",
147
+ ],
148
+ "description" :
149
+ """A row in the bldgHVACTable. Each row represents a particular
150
+ office in the building, qualified by its floor and office
151
+ number. A given row instance can be created or deleted by
152
+ set operations upon its bldgHVACStatus columnar
153
+ object instance.""",
154
+ }, # row
155
+ "bldgHVACFloor" : {
156
+ "nodetype" : "column",
157
+ "moduleName" : "BLDG-HVAC-MIB",
158
+ "oid" : "1.3.6.1.3.122.1.1.1.1",
159
+ "status" : "current",
160
+ "syntax" : {
161
+ "type" : {
162
+ "basetype" : "Unsigned32",
163
+ "ranges" : [
164
+ {
165
+ "min" : "1",
166
+ "max" : "1000"
167
+ },
168
+ ],
169
+ "range" : {
170
+ "min" : "1",
171
+ "max" : "1000"
172
+ },
173
+ },
174
+ },
175
+ "access" : "noaccess",
176
+ "description" :
177
+ """This portion of the index indicates the floor of the
178
+ building. The ground floor is considered the
179
+ first floor. For the purposes of this example,
180
+ floors under the ground floor cannot be
181
+ controlled using this MIB module.""",
182
+ }, # column
183
+ "bldgHVACOffice" : {
184
+ "nodetype" : "column",
185
+ "moduleName" : "BLDG-HVAC-MIB",
186
+ "oid" : "1.3.6.1.3.122.1.1.1.2",
187
+ "status" : "current",
188
+ "syntax" : {
189
+ "type" : {
190
+ "basetype" : "Unsigned32",
191
+ "ranges" : [
192
+ {
193
+ "min" : "1",
194
+ "max" : "2147483647"
195
+ },
196
+ ],
197
+ "range" : {
198
+ "min" : "1",
199
+ "max" : "2147483647"
200
+ },
201
+ },
202
+ },
203
+ "access" : "noaccess",
204
+ "description" :
205
+ """This second component of the index specifies the
206
+ office number.""",
207
+ }, # column
208
+ "bldgHVACCfgTemplate" : {
209
+ "nodetype" : "column",
210
+ "moduleName" : "BLDG-HVAC-MIB",
211
+ "oid" : "1.3.6.1.3.122.1.1.1.3",
212
+ "status" : "current",
213
+ "syntax" : {
214
+ "type" : { "module" :"", "name" : "Unsigned32"},
215
+ },
216
+ "access" : "readwrite",
217
+ "description" :
218
+ """The index (bldgHVACCfgTemplateIndex instance)
219
+ of an entry in the 'bldgHVACCfgTemplateTable'.
220
+ The bldgHVACCfgTable row instance referenced
221
+ is a pre-made configuration 'template'
222
+ that represents the configuration described
223
+ by the bldgHVACCfgTemplateInfoDescr object. Note
224
+ that not all configurations will be under a
225
+ defined template. As a result, a row in this
226
+ bldgHVACTable may point to an entry in the
227
+ bldgHVACCfgTemplateTable that does not in turn
228
+ have a reference (bldgHVACCfgTemplateInfo) to an
229
+ entry in the bldgHVACCfgTemplateInfoTable. The
230
+ benefit of this approach is that all
231
+ configuration information is available in one
232
+ table whether all elements in the system are
233
+ derived from configured templates or not.
234
+
235
+ Where the instance value for this colunmar object
236
+ is zero, this row represents data for an office
237
+ whose HVAC status can be monitored using the
238
+ read-only columnar object instances of this
239
+ row, but is not under the configuration control
240
+
241
+
242
+
243
+ of the agent.""",
244
+ }, # column
245
+ "bldgHVACFanSpeed" : {
246
+ "nodetype" : "column",
247
+ "moduleName" : "BLDG-HVAC-MIB",
248
+ "oid" : "1.3.6.1.3.122.1.1.1.4",
249
+ "status" : "current",
250
+ "syntax" : {
251
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
252
+ },
253
+ "access" : "readonly",
254
+ "units" : "revolutions per minute",
255
+ "description" :
256
+ """Shows the revolutions per minute of the fan. Fan speed
257
+ will vary based on the difference between
258
+ bldgHVACCfgTemplateDesiredTemp and bldgHVACCurrentTemp. The
259
+ speed is measured in revolutions of the fan blade per minute.""",
260
+ }, # column
261
+ "bldgHVACCurrentTemp" : {
262
+ "nodetype" : "column",
263
+ "moduleName" : "BLDG-HVAC-MIB",
264
+ "oid" : "1.3.6.1.3.122.1.1.1.5",
265
+ "status" : "current",
266
+ "syntax" : {
267
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
268
+ },
269
+ "access" : "readonly",
270
+ "units" : "degrees in celsius",
271
+ "description" :
272
+ """The current measured temperature in the office. Should
273
+ the current temperature be measured at a value of less
274
+ than zero degrees celsius, a read of the instance
275
+ for this object will return a value of zero.""",
276
+ }, # column
277
+ "bldgHVACCoolOrHeatMins" : {
278
+ "nodetype" : "column",
279
+ "moduleName" : "BLDG-HVAC-MIB",
280
+ "oid" : "1.3.6.1.3.122.1.1.1.6",
281
+ "status" : "current",
282
+ "syntax" : {
283
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
284
+ },
285
+ "access" : "readonly",
286
+ "units" : "minutes",
287
+ "description" :
288
+ """The total number of heating or cooling minutes that have
289
+ been consumed since the row was activated. Notice that
290
+ whether the minutes represent heating or cooling is a
291
+ function of the configuration of this row. If the system
292
+ is re-initialized from a cooling to heating function or
293
+ vice versa, then the counter would start over again. This
294
+ effect is similar to a reconfiguration of some network
295
+ interface cards. When parameters that impact
296
+ configuration are changed, the subsystem must be
297
+ re-initialized. Discontinuities in the value of this counter
298
+ can occur at re-initialization of the management system,
299
+ and at other times as indicated by the value of
300
+ bldgHVACDiscontinuityTime.""",
301
+ }, # column
302
+ "bldgHVACDiscontinuityTime" : {
303
+ "nodetype" : "column",
304
+ "moduleName" : "BLDG-HVAC-MIB",
305
+ "oid" : "1.3.6.1.3.122.1.1.1.7",
306
+ "status" : "current",
307
+ "syntax" : {
308
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeStamp"},
309
+ },
310
+ "access" : "readonly",
311
+ "description" :
312
+ """The value of sysUpTime on the most recent occasion at which
313
+ any heating or cooling operation for the office designated
314
+ by this row instance experienced a discontinuity. If
315
+ no such discontinuities have occurred since the last re-
316
+ initialization of the this row, then this object contains a
317
+ zero value.""",
318
+ }, # column
319
+ "bldgHVACOwner" : {
320
+ "nodetype" : "column",
321
+ "moduleName" : "BLDG-HVAC-MIB",
322
+ "oid" : "1.3.6.1.3.122.1.1.1.8",
323
+ "status" : "current",
324
+ "syntax" : {
325
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
326
+ },
327
+ "access" : "readwrite",
328
+ "description" :
329
+ """The identity of the operator/system that
330
+ last modified this entry. When a new entry
331
+ is created, a valid SnmpAdminString must
332
+ be supplied. If, on the other hand, this
333
+ entry is populated by the agent 'discovering'
334
+ unconfigured rooms, the empty string is a valid
335
+ value for this object.""",
336
+ }, # column
337
+ "bldgHVACStorageType" : {
338
+ "nodetype" : "column",
339
+ "moduleName" : "BLDG-HVAC-MIB",
340
+ "oid" : "1.3.6.1.3.122.1.1.1.9",
341
+ "status" : "current",
342
+ "syntax" : {
343
+ "type" : { "module" :"SNMPv2-TC", "name" : "StorageType"},
344
+ },
345
+ "access" : "readwrite",
346
+ "description" :
347
+ """The persistence of this row of the table in system storage,
348
+ as it pertains to permanence across system resets. A columnar
349
+ instance of this object with value 'permanent' need not allow
350
+ write-access to any of the columnar object instances in the
351
+ containing row.""",
352
+ }, # column
353
+ "bldgHVACStatus" : {
354
+ "nodetype" : "column",
355
+ "moduleName" : "BLDG-HVAC-MIB",
356
+ "oid" : "1.3.6.1.3.122.1.1.1.10",
357
+ "status" : "current",
358
+ "syntax" : {
359
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
360
+ },
361
+ "access" : "readwrite",
362
+ "description" :
363
+ """Controls and reflects the creation and activation status of
364
+ a row in this table.
365
+
366
+ No attempt to modify a row columnar object instance value in
367
+
368
+
369
+
370
+ the bldgHVACTable should be issued while the value of
371
+ bldgHVACStatus is active(1). Should an agent receive a SET
372
+ PDU attempting such a modification in this state, an
373
+ inconsistentValue error should be returned as a result of
374
+ the SET attempt.""",
375
+ }, # column
376
+ "bldgHVACCfgTemplateInfoTable" : {
377
+ "nodetype" : "table",
378
+ "moduleName" : "BLDG-HVAC-MIB",
379
+ "oid" : "1.3.6.1.3.122.1.2",
380
+ "status" : "current",
381
+ "description" :
382
+ """This table provides unique string identification for
383
+ HVAC templates in a network. If it were necessary to
384
+ configure rooms to deliver a particular quality of climate
385
+ control with regard to cooling or heating, the index string
386
+ of a row in this table could be the template name.
387
+ The bldgHVACCfgCfgTemplateInfoDescription
388
+ contains a brief description of the template service objective
389
+ such as: provides summer cooling settings for executive
390
+ offices. The bldgHVACCfgTemplateInfo in the
391
+ bldgHVACCfgTemplateTable will contain the pointer to the
392
+ relevant row in this table if it is intended that items
393
+ that point to a row in the bldgHVACCfgTemplateInfoTable be
394
+ identifiable as being under template control though this
395
+ mechanism.""",
396
+ }, # table
397
+ "bldgHVACCfgTemplateInfoEntry" : {
398
+ "nodetype" : "row",
399
+ "moduleName" : "BLDG-HVAC-MIB",
400
+ "oid" : "1.3.6.1.3.122.1.2.1",
401
+ "create" : "true",
402
+ "status" : "current",
403
+ "linkage" : [
404
+ "bldgHVACCfgTemplateInfoIndex",
405
+ ],
406
+ "description" :
407
+ """Each row represents a particular template and
408
+ description. A given row instance can be created or
409
+ deleted by set operations upon its
410
+ bldgHVACCfgTemplateInfoStatus columnar object
411
+ instance.""",
412
+ }, # row
413
+ "bldgHVACCfgTemplateInfoIndex" : {
414
+ "nodetype" : "column",
415
+ "moduleName" : "BLDG-HVAC-MIB",
416
+ "oid" : "1.3.6.1.3.122.1.2.1.1",
417
+ "status" : "current",
418
+ "syntax" : {
419
+ "type" : {
420
+ "basetype" : "Unsigned32",
421
+ "ranges" : [
422
+ {
423
+ "min" : "1",
424
+ "max" : "2147483647"
425
+ },
426
+ ],
427
+ "range" : {
428
+ "min" : "1",
429
+ "max" : "2147483647"
430
+ },
431
+ },
432
+ },
433
+ "access" : "noaccess",
434
+ "description" :
435
+ """The unique index to a row in this table.""",
436
+ }, # column
437
+ "bldgHVACCfgTemplateInfoID" : {
438
+ "nodetype" : "column",
439
+ "moduleName" : "BLDG-HVAC-MIB",
440
+ "oid" : "1.3.6.1.3.122.1.2.1.2",
441
+ "status" : "current",
442
+ "syntax" : {
443
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
444
+ },
445
+ "access" : "readwrite",
446
+ "description" :
447
+ """Textual identifier for this table row, and, consequently
448
+ the template. This should be a unique name within
449
+ an administrative domain for a particular template so that
450
+ all systems in a network that are under the same template
451
+ can have the same 'handle' (e.g., 'Executive Offices',
452
+ 'Lobby Areas').""",
453
+ }, # column
454
+ "bldgHVACCfgTemplateInfoDescr" : {
455
+ "nodetype" : "column",
456
+ "moduleName" : "BLDG-HVAC-MIB",
457
+ "oid" : "1.3.6.1.3.122.1.2.1.3",
458
+ "status" : "current",
459
+ "syntax" : {
460
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
461
+ },
462
+ "access" : "readwrite",
463
+ "description" :
464
+ """A general description of the template. One example might
465
+ be - Controls the cooling for offices on higher floors
466
+ during the summer.""",
467
+ }, # column
468
+ "bldgHVACCfgTemplateInfoOwner" : {
469
+ "nodetype" : "column",
470
+ "moduleName" : "BLDG-HVAC-MIB",
471
+ "oid" : "1.3.6.1.3.122.1.2.1.4",
472
+ "status" : "current",
473
+ "syntax" : {
474
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
475
+ },
476
+ "access" : "readwrite",
477
+ "description" :
478
+ """The identity of the operator/system that last modified
479
+ this entry.""",
480
+ }, # column
481
+ "bldgHVACCfgTemplateInfoStatus" : {
482
+ "nodetype" : "column",
483
+ "moduleName" : "BLDG-HVAC-MIB",
484
+ "oid" : "1.3.6.1.3.122.1.2.1.5",
485
+ "status" : "current",
486
+ "syntax" : {
487
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
488
+ },
489
+ "access" : "readwrite",
490
+ "description" :
491
+ """The activation status of this row.
492
+
493
+ No attempt to modify a row columnar object instance value in
494
+ the bldgHVACCfgTemplateInfo Table should be issued while the
495
+ value of bldgHVACCfgTemplateInfoStatus is active(1).
496
+ Should an agent receive a SET PDU attempting such a modification
497
+ in this state, an inconsistentValue error should be returned as
498
+ a result of the SET attempt.""",
499
+ }, # column
500
+ "bldgHVACCfgTemplateInfoStorType" : {
501
+ "nodetype" : "column",
502
+ "moduleName" : "BLDG-HVAC-MIB",
503
+ "oid" : "1.3.6.1.3.122.1.2.1.6",
504
+ "status" : "current",
505
+ "syntax" : {
506
+ "type" : { "module" :"SNMPv2-TC", "name" : "StorageType"},
507
+ },
508
+ "access" : "readwrite",
509
+ "description" :
510
+ """The persistence of this row of the table in system storage,
511
+ as it pertains to permanence across system resets. A columnar
512
+ instance of this object with value 'permanent' need not allow
513
+ write-access to any of the columnar object instances in the
514
+ containing row.""",
515
+ }, # column
516
+ "bldgHVACCfgTemplateTable" : {
517
+ "nodetype" : "table",
518
+ "moduleName" : "BLDG-HVAC-MIB",
519
+ "oid" : "1.3.6.1.3.122.1.3",
520
+ "status" : "current",
521
+ "description" :
522
+ """This table contains the templates, which
523
+ can be used to set defaults that will
524
+ be applied to specific offices. The application
525
+ of those values is accomplished by having a row
526
+ instance of the bldgHVACTable reference a row of
527
+ this table (by the value of the former's
528
+ bldgHVACCfgTemplate columnar instance). Identifying
529
+ information concerning a row instance of this table
530
+ can be found in the columnar data of the row instance
531
+ of the bldgHVACCfgTemplateInfoTable entry referenced
532
+ by the bldgHVACCfgTemplateInfo columnar object of
533
+ this table.""",
534
+ }, # table
535
+ "bldgHVACCfgTemplateEntry" : {
536
+ "nodetype" : "row",
537
+ "moduleName" : "BLDG-HVAC-MIB",
538
+ "oid" : "1.3.6.1.3.122.1.3.1",
539
+ "create" : "true",
540
+ "status" : "current",
541
+ "linkage" : [
542
+ "bldgHVACCfgTemplateIndex",
543
+ ],
544
+ "description" :
545
+ """Each row represents a single set of template parameters
546
+ that can be applied to selected instances - in this case
547
+ offices. These policies will be turned on and off by the
548
+ policy module through its scheduling facilities.
549
+
550
+ A given row instance can be created or
551
+ deleted by set operations upon its
552
+ bldgHVACCfgTemplateStatus columnar object instance.""",
553
+ }, # row
554
+ "bldgHVACCfgTemplateIndex" : {
555
+ "nodetype" : "column",
556
+ "moduleName" : "BLDG-HVAC-MIB",
557
+ "oid" : "1.3.6.1.3.122.1.3.1.1",
558
+ "status" : "current",
559
+ "syntax" : {
560
+ "type" : {
561
+ "basetype" : "Unsigned32",
562
+ "ranges" : [
563
+ {
564
+ "min" : "1",
565
+ "max" : "2147483647"
566
+ },
567
+ ],
568
+ "range" : {
569
+ "min" : "1",
570
+ "max" : "2147483647"
571
+ },
572
+ },
573
+ },
574
+ "access" : "noaccess",
575
+ "description" :
576
+ """A unique value for each defined template in this
577
+ table. This value can be referenced as a row index
578
+ by any MIB module that needs access to this information.
579
+ The bldgHVACCfgTemplate will point to entries in this
580
+ table.""",
581
+ }, # column
582
+ "bldgHVACCfgTemplateDesiredTemp" : {
583
+ "nodetype" : "column",
584
+ "moduleName" : "BLDG-HVAC-MIB",
585
+ "oid" : "1.3.6.1.3.122.1.3.1.2",
586
+ "status" : "current",
587
+ "syntax" : {
588
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Gauge32"},
589
+ },
590
+ "access" : "readwrite",
591
+ "units" : "degrees in celsius",
592
+ "description" :
593
+ """This is the desired temperature setting. It might be
594
+ changed at different times of the day or based on
595
+ seasonal conditions. It is permitted to change this value
596
+ by first moving the row to an inactive state, making the
597
+
598
+
599
+
600
+ change and then reactivating the row.""",
601
+ }, # column
602
+ "bldgHVACCfgTemplateCoolOrHeat" : {
603
+ "nodetype" : "column",
604
+ "moduleName" : "BLDG-HVAC-MIB",
605
+ "oid" : "1.3.6.1.3.122.1.3.1.3",
606
+ "status" : "current",
607
+ "syntax" : {
608
+ "type" : { "module" :"BLDG-HVAC-MIB", "name" : "BldgHvacOperation"},
609
+ },
610
+ "access" : "readwrite",
611
+ "description" :
612
+ """This controls the heating and cooling mechanism and is
613
+ set-able by building maintenance. It is permitted to
614
+ change this value by first moving the row to an inactive
615
+ state, making the change and then reactivating the row.""",
616
+ }, # column
617
+ "bldgHVACCfgTemplateInfo" : {
618
+ "nodetype" : "column",
619
+ "moduleName" : "BLDG-HVAC-MIB",
620
+ "oid" : "1.3.6.1.3.122.1.3.1.4",
621
+ "status" : "current",
622
+ "syntax" : {
623
+ "type" : { "module" :"", "name" : "Unsigned32"},
624
+ },
625
+ "access" : "readwrite",
626
+ "description" :
627
+ """This object points to a row in the
628
+ bldgHVACCfgTemplateInfoTable. This controls the
629
+ heating and cooling mechanism and is set-able by
630
+ building maintenance. It is permissible to change
631
+ this value by first moving the row to an inactive
632
+ state, making the change and then reactivating
633
+ the row. A value of zero means that this entry
634
+ is not associated with a named template found
635
+ in the bldgHVACCfgTemplateInfoTable.""",
636
+ }, # column
637
+ "bldgHVACCfgTemplateOwner" : {
638
+ "nodetype" : "column",
639
+ "moduleName" : "BLDG-HVAC-MIB",
640
+ "oid" : "1.3.6.1.3.122.1.3.1.5",
641
+ "status" : "current",
642
+ "syntax" : {
643
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
644
+ },
645
+ "access" : "readwrite",
646
+ "description" :
647
+ """The identity of the administrative entity
648
+ that created this row of the table.""",
649
+ }, # column
650
+ "bldgHVACCfgTemplateStorage" : {
651
+ "nodetype" : "column",
652
+ "moduleName" : "BLDG-HVAC-MIB",
653
+ "oid" : "1.3.6.1.3.122.1.3.1.6",
654
+ "status" : "current",
655
+ "syntax" : {
656
+ "type" : { "module" :"SNMPv2-TC", "name" : "StorageType"},
657
+ },
658
+ "access" : "readwrite",
659
+ "description" :
660
+ """The persistence of this row of the table across
661
+ system resets. A columnar instance of this object with
662
+ value 'permanent' need not allow write-access to any
663
+ of the columnar object instances in the containing row.""",
664
+ }, # column
665
+ "bldgHVACCfgTemplateStatus" : {
666
+ "nodetype" : "column",
667
+ "moduleName" : "BLDG-HVAC-MIB",
668
+ "oid" : "1.3.6.1.3.122.1.3.1.7",
669
+ "status" : "current",
670
+ "syntax" : {
671
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
672
+ },
673
+ "access" : "readwrite",
674
+ "description" :
675
+ """The activation status of this row of the table.
676
+
677
+ No attempt to modify a row columnar object instance value in
678
+ the bldgHVACCfgTemplateTable should be issued while the
679
+ value of bldgHVACCfgTemplateStatus is active(1).
680
+ Should an agent receive a SET PDU attempting such a modification
681
+ in this state, an inconsistentValue error should be returned as
682
+ a result of the SET attempt.""",
683
+ }, # column
684
+ "bldgConformance" : {
685
+ "nodetype" : "node",
686
+ "moduleName" : "BLDG-HVAC-MIB",
687
+ "oid" : "1.3.6.1.3.122.2",
688
+ }, # node
689
+ "bldgCompliances" : {
690
+ "nodetype" : "node",
691
+ "moduleName" : "BLDG-HVAC-MIB",
692
+ "oid" : "1.3.6.1.3.122.2.1",
693
+ }, # node
694
+ "bldgGroups" : {
695
+ "nodetype" : "node",
696
+ "moduleName" : "BLDG-HVAC-MIB",
697
+ "oid" : "1.3.6.1.3.122.2.2",
698
+ }, # node
699
+ }, # nodes
700
+
701
+ "groups" : {
702
+ "bldgHVACObjectsGroup" : {
703
+ "nodetype" : "group",
704
+ "moduleName" : "BLDG-HVAC-MIB",
705
+ "oid" : "1.3.6.1.3.122.2.2.1",
706
+ "status" : "current",
707
+ "members" : {
708
+ "bldgHVACCfgTemplate" : {
709
+ "nodetype" : "member",
710
+ "module" : "BLDG-HVAC-MIB"
711
+ },
712
+ "bldgHVACFanSpeed" : {
713
+ "nodetype" : "member",
714
+ "module" : "BLDG-HVAC-MIB"
715
+ },
716
+ "bldgHVACCurrentTemp" : {
717
+ "nodetype" : "member",
718
+ "module" : "BLDG-HVAC-MIB"
719
+ },
720
+ "bldgHVACCoolOrHeatMins" : {
721
+ "nodetype" : "member",
722
+ "module" : "BLDG-HVAC-MIB"
723
+ },
724
+ "bldgHVACDiscontinuityTime" : {
725
+ "nodetype" : "member",
726
+ "module" : "BLDG-HVAC-MIB"
727
+ },
728
+ "bldgHVACOwner" : {
729
+ "nodetype" : "member",
730
+ "module" : "BLDG-HVAC-MIB"
731
+ },
732
+ "bldgHVACStatus" : {
733
+ "nodetype" : "member",
734
+ "module" : "BLDG-HVAC-MIB"
735
+ },
736
+ "bldgHVACStorageType" : {
737
+ "nodetype" : "member",
738
+ "module" : "BLDG-HVAC-MIB"
739
+ },
740
+ "bldgHVACCfgTemplateInfoID" : {
741
+ "nodetype" : "member",
742
+ "module" : "BLDG-HVAC-MIB"
743
+ },
744
+ "bldgHVACCfgTemplateInfoDescr" : {
745
+ "nodetype" : "member",
746
+ "module" : "BLDG-HVAC-MIB"
747
+ },
748
+ "bldgHVACCfgTemplateInfoOwner" : {
749
+ "nodetype" : "member",
750
+ "module" : "BLDG-HVAC-MIB"
751
+ },
752
+ "bldgHVACCfgTemplateInfoStatus" : {
753
+ "nodetype" : "member",
754
+ "module" : "BLDG-HVAC-MIB"
755
+ },
756
+ "bldgHVACCfgTemplateInfoStorType" : {
757
+ "nodetype" : "member",
758
+ "module" : "BLDG-HVAC-MIB"
759
+ },
760
+ "bldgHVACCfgTemplateDesiredTemp" : {
761
+ "nodetype" : "member",
762
+ "module" : "BLDG-HVAC-MIB"
763
+ },
764
+ "bldgHVACCfgTemplateCoolOrHeat" : {
765
+ "nodetype" : "member",
766
+ "module" : "BLDG-HVAC-MIB"
767
+ },
768
+ "bldgHVACCfgTemplateInfo" : {
769
+ "nodetype" : "member",
770
+ "module" : "BLDG-HVAC-MIB"
771
+ },
772
+ "bldgHVACCfgTemplateOwner" : {
773
+ "nodetype" : "member",
774
+ "module" : "BLDG-HVAC-MIB"
775
+ },
776
+ "bldgHVACCfgTemplateStorage" : {
777
+ "nodetype" : "member",
778
+ "module" : "BLDG-HVAC-MIB"
779
+ },
780
+ "bldgHVACCfgTemplateStatus" : {
781
+ "nodetype" : "member",
782
+ "module" : "BLDG-HVAC-MIB"
783
+ },
784
+ }, # members
785
+ "description" :
786
+ """The bldgHVACObjects Group.""",
787
+ }, # group
788
+ }, # groups
789
+
790
+ "compliances" : {
791
+ "bldgCompliance" : {
792
+ "nodetype" : "compliance",
793
+ "moduleName" : "BLDG-HVAC-MIB",
794
+ "oid" : "1.3.6.1.3.122.2.1.1",
795
+ "status" : "current",
796
+ "description" :
797
+ """The requirements for conformance to the BLDG-HVAC-MIB. The
798
+ bldgHVACObjects group must be implemented to conform to the
799
+ BLDG-HVAC-MIB.""",
800
+ "requires" : {
801
+ "bldgHVACObjectsGroup" : {
802
+ "nodetype" : "optional",
803
+ "module" : "BLDG-HVAC-MIB",
804
+ "description" :
805
+ """The bldgHVACObjects is mandatory for all systems that
806
+ support HVAC systems.""",
807
+ },
808
+ }, # requires
809
+ }, # compliance
810
+ }, # compliances
811
+
812
+ }