openstudio-standards 0.8.4 → 0.8.5.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (289) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.osm +30 -30
  3. data/data/geometry/ASHRAECourthouse.osm +22 -22
  4. data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
  5. data/data/geometry/DEER_Asm.osm +1 -1
  6. data/data/geometry/DEER_ECC.osm +1 -1
  7. data/data/geometry/DEER_EPr.osm +1 -1
  8. data/data/geometry/DEER_ERC.osm +1 -1
  9. data/data/geometry/DEER_ESe.osm +1 -1
  10. data/data/geometry/DEER_EUn.osm +1 -1
  11. data/data/geometry/DEER_Hsp.osm +1 -1
  12. data/data/geometry/DEER_Htl.osm +1 -1
  13. data/data/geometry/DEER_MBT.osm +1 -1
  14. data/data/geometry/DEER_MFm.osm +1 -1
  15. data/data/geometry/DEER_Nrs.osm +1 -1
  16. data/data/geometry/DEER_OfL.osm +1 -1
  17. data/data/geometry/DEER_OfS.osm +1 -1
  18. data/data/geometry/DEER_RFF.osm +1 -1
  19. data/data/geometry/DEER_RSD.osm +1 -1
  20. data/data/geometry/DEER_Rt3.osm +1 -1
  21. data/data/geometry/DEER_RtS.osm +1 -1
  22. data/data/standards/export_OpenStudio_libraries.rb +2 -3
  23. data/data/standards/test_performance_expected_dd_results.csv +42 -42
  24. data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
  25. data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
  26. data/lib/openstudio-standards/btap/activity.rb +480 -0
  27. data/lib/openstudio-standards/btap/attributes.rb +166 -0
  28. data/lib/openstudio-standards/btap/bridging.rb +561 -1402
  29. data/lib/openstudio-standards/btap/btap.rb +4 -2
  30. data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
  31. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
  32. data/lib/openstudio-standards/btap/{costing/common_paths.rb → common_paths.rb} +14 -11
  33. data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
  34. data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
  35. data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
  36. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
  37. data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
  38. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting.csv +59 -59
  39. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_hvac.csv +1019 -1032
  40. data/lib/openstudio-standards/btap/costing/btap_costing.rb +3 -7
  41. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +1 -5
  42. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +5 -4
  43. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +1 -1
  44. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +112 -181
  45. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +4 -4
  46. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +2 -1
  47. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +3 -3
  48. data/lib/openstudio-standards/btap/costing/test_list.txt +15 -17
  49. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +10 -9
  50. data/lib/openstudio-standards/btap/geometry.rb +86 -6
  51. data/lib/openstudio-standards/btap/structure.rb +657 -0
  52. data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
  53. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
  54. data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
  55. data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
  56. data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
  57. data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
  58. data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
  59. data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
  60. data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
  61. data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
  62. data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
  63. data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
  64. data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
  65. data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
  66. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
  67. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
  68. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
  69. data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
  70. data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
  71. data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
  72. data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
  73. data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
  74. data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
  75. data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
  76. data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
  77. data/lib/openstudio-standards/hvac/components/component.rb +39 -0
  78. data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
  79. data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
  80. data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
  81. data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
  82. data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
  83. data/lib/openstudio-standards/hvac/conversions.rb +222 -0
  84. data/lib/openstudio-standards/hvac/curves.rb +192 -0
  85. data/lib/openstudio-standards/hvac/helpers.rb +357 -0
  86. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
  87. data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
  88. data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
  89. data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
  90. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
  91. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
  92. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
  93. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  99. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
  100. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  101. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  102. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
  103. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
  111. data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
  112. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
  113. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
  114. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
  115. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
  116. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
  117. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
  118. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
  119. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
  120. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
  121. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
  122. data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
  123. data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
  124. data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
  125. data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
  126. data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
  127. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
  128. data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
  129. data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
  130. data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
  131. data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
  132. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
  133. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
  134. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
  135. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
  136. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
  137. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
  138. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
  139. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
  140. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
  141. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
  142. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
  143. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
  144. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
  145. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
  146. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
  147. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
  148. data/lib/openstudio-standards/standards/Standards.Model.rb +6 -11
  149. data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
  150. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
  151. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
  152. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
  153. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
  154. data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
  155. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
  156. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
  157. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
  158. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
  159. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
  160. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
  161. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
  162. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  163. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
  164. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
  165. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
  166. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  167. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
  168. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
  169. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
  170. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
  171. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  172. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
  182. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
  183. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
  184. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
  185. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
  186. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
  187. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
  188. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  189. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  191. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
  192. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
  193. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
  194. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
  195. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
  196. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
  197. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
  198. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
  199. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
  200. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
  202. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
  203. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
  204. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
  205. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +1 -0
  206. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
  207. data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
  208. data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
  209. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +19 -10
  210. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
  211. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
  212. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
  213. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +69 -92
  214. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +2 -1
  215. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
  216. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
  217. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
  218. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +32 -0
  219. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +18 -0
  220. data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
  221. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +5 -5
  222. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +2 -0
  223. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +30 -141
  224. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +233 -112
  225. data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
  226. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -2
  227. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
  228. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
  229. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
  230. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
  231. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +16 -4
  232. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +65 -42
  233. data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
  234. data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
  235. data/lib/openstudio-standards/version.rb +1 -1
  236. data/lib/openstudio-standards/weather/stat_file.rb +2 -2
  237. data/lib/openstudio-standards.rb +55 -38
  238. metadata +106 -66
  239. data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +0 -61
  240. data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +0 -1904
  241. data/lib/openstudio-standards/hvac/components/create.rb +0 -169
  242. data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
  243. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
  244. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
  245. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
  246. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
  247. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
  248. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
  249. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
  250. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
  251. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
  252. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
  253. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
  254. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
  255. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
  256. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
  257. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
  258. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
  259. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
  260. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
  261. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
  262. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
  263. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
  264. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
  265. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
  266. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
  267. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
  268. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
  269. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
  270. data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
  271. data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
  272. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/ConstructionProperties.csv +0 -0
  273. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/Constructions.csv +0 -0
  274. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/construction_sets.csv +0 -0
  275. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/constructions_opaque.csv +0 -0
  276. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/costs_local_factors.csv +0 -0
  277. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/hvac_vent_ahu.csv +0 -0
  278. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting_sets.csv +0 -0
  279. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/locations.csv +0 -0
  280. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_glazing.csv +0 -0
  281. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_lighting.csv +0 -0
  282. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_opaque.csv +0 -0
  283. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
  284. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
  285. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
  286. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
  287. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
  288. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
  289. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
@@ -0,0 +1,164 @@
1
+ materials_opaque_id,description,type,quantity,per m2,Product Category,Embodied Carbon (A1-A5),Embodied Carbon (A-C),Environmental Product Declaration (EPD)
2
+ 1,gypsum wallboard 0.5 in thick,Unit,1.0,1.0,"Solid Sheets, gypsum board, fiber, 13 mm",2.634,1.806,"Lightwieight gypsum boards for wall and ceiling, 12.7 mm (1/2 in), 6.5 kg/m2, 2438-4877 x 1219 mm, 1/2 in. Sheetrock ® Brand Ultralight Panels (USG)"
3
+ 2,"standard wood studs with single bottom plate and double top plate, 16"" O.C., pneumatic nailer",Assembly,0.1,0.011,"Wood Rigid Profiles, softwood lumber",0.11,4.292,"Softwood lumber, kiln-dried and planed, 19 mm, 460 kg/m3, 15% moisture content (American Wood Council, Canadian Wood Council)"
4
+ 3,polyethylene 4 ml vapour barrier,Unit,0.01,1.0,"Vapor Barriers, polyethylene, 3 mil",0.125,3.485,"Polyethylene vapour barrier membrane, 0.15 mm, 0.14 kg/m2 (One Click LCA)"
5
+ 4,"foil face fibreglass batts, 5"" thick, 15"" wide, RSI 3.36",Unit,1.0,0.127,"Blanket Thermal Insulation, fiberglass",13.296,10.394,Average
6
+ 5,"plywood sheathing, CDX, 0.5 in, pneumatic nailer",Unit,1.0,0.0127,"Solid Sheets, softwood plywood",11.218,5.299,"Softwood plywood, 477.33 kg/m3 (Canadian Wood Council)"
7
+ 6,"weather barrier, spunbonded polyethylene",Unit,1.0,1.0,"Vapor Barriers, polyethylene, 3 mil",0.545,5.773,"Polyethylene vapour barrier membrane, 0.15 mm, 0.14 kg/m2 (One Click LCA)"
8
+ 7,"wood siding T&G ""B"" grade",Unit,1.0,1.0,"Wood Exterior Siding, tongue and groove",15.686,15.397,Average
9
+ 8,"joint sealants. tapes, foam, adhesive ",Assembly,0.001,0.05,"Construction Sealants, exterior",0.589,0.354,"Resinous components for structural strengthening, sealing and bonding, 1650 kg/m3, Sikadur-30 (Sika Canada)"
10
+ 9,"waterproof sealer, 1 coat, sprayed",Unit,1.0,1.0,"Fluid Applied Waterproofing, cold applied",0.686,58.436,"Concrete waterproofer, 0.162 kg/m2, 980 N/A White (Behr Process LLC)"
11
+ 10,"stains, paints, 2 coats sprayed",Unit,1.0,0.182,"General Purpose Paints and Varnishes, water based latex, 2 coats",0.91,6.971,"Acrylic paint, semi-gloss finish, 0.118 kg/m2, 8020, 7020 (MF Paints)"
12
+ 11,"galvanized LB studs, 16 ga x 3-5/8\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging",Unit,0.1,4.3,"Ferrous Metal Rigid Profiles, galvanized steel stud",17.135,10.424,"Galvanized steel stud framing profiles per m2 (air gap included), UD and CD profiles included, wing width: 6 mm, flange width:50 mm, steel thicnkess:0.6 mm (23 gauge), 450 mm spacing, 2.4 kg/m2 (One Click LCA)"
13
+ 12,Polymer EIFS with 2 in EPS and finish,Unit,1.0,1.5,,56.461,5.164,
14
+ 13,"standard wood studs with single bottom plate and double top plate, 16"" O.C.",Assembly,1.0,0.011,"Wood Rigid Profiles, softwood lumber",2.594,1.272,"Softwood lumber, kiln-dried and planed, 19 mm, 460 kg/m3, 15% moisture content (American Wood Council, Canadian Wood Council)"
15
+ 14,"vinyl siding, clapboard profile, woodgrain texture, 0.048 "" thick, 8"" width",Unit,1.0,1.0,"Plastic Exterior Siding, vinyl",1.488,14.362,"Horizontal vinyl siding, T: 0.04 inches, L: 12 ft, W: 0.75 ft, 89.27 lbs/ft3 (VSI)"
16
+ 15,"aluminum flashing, mill finish. 0.013 "" thick",Assembly,1.0,1.3,"Roof Flashings, aluminum",57.84,44.589,"Thermally improved aluminium extrusions (profiles), mill finished (Aluminum Extruders Council (AEC))"
17
+ 16,"metal decking strips, galvanized, 18 gauge",Unit,0.0766,9.5,"Thin Sheets, galvanized steel decking",86.005,86.418,"Steel roof and floor deck, North America average, 38-76 mm (Steel Deck Institute)"
18
+ 17,"10 yr finish metal siding, 24 gauge, 0.0239 "" thick with fasteners",Unit,1.0,1.0,"Metal Exterior Siding, steel",77.052,19.698,Average
19
+ 18,"aluminum closure strips, mill finish. 0.032 "" thick",Unit,0.111,2.19,"Roof Flashings, aluminum",15.105,70.23,"Thermally improved aluminium extrusions (profiles), mill finished (Aluminum Extruders Council (AEC))"
20
+ 19,"joint sealants. tapes, foam, adhesive ",Assembly,0.00397,0.05,"Construction Sealants, exterior",0.02,0.605,"Resinous components for structural strengthening, sealing and bonding, 1650 kg/m3, Sikadur-30 (Sika Canada)"
21
+ 20,"Brick walls, face brick, red, running bond, 6.75/SF, 4\"" thick, includes mortar",Unit,1.0,1.0,Face Bricks,81.246,22.534,"Clay bricks, 2060 kg/m3, 15.70% moisture content (Shaw Group)"
22
+ 21,"Lintel angle, structural, unpainted, under 500 lb., shop fabricated",Unit,1.0,4.0,"Ferrous Metal Rigid Profiles, structural steel",25.797,38.542,"Cold roll formed steel sections, 7800 kg/m3 (Canadian Sheet Steel Building Institute (CSSBI))"
23
+ 22,"Sheet metal flashing, 0.019"" thick",Assembly,0.1,3.79,"Roof Flashings, metal",14.069,1.326,"Cold roll formed steel panels, 7800 kg/m3 (Canadian Sheet Steel Building Institute (CSSBI))"
24
+ 23,"standard wood studs with single bottom plate and double top plate, 16"" O.C.",Assembly,1.0,0.011,"Wood Rigid Profiles, softwood lumber",4.449,4.289,"Softwood lumber, kiln-dried and planed, 19 mm, 460 kg/m3, 15% moisture content (American Wood Council, Canadian Wood Council)"
25
+ 24,"Block, tooled joints both sides, includes morter, excludes, scaffolding, reinforcing, grout",Unit,1.0,13.0,"Concrete Blocks, 190 mm",32.2,49.677,"Medium density concrete block, solid, 440 x 215 x 100mm (17x8x4in), 1425 kg/m3, 13.25 kg/unit (One Click LCA)"
26
+ 25,"masonry reinforcing bars, galvanized ladder type 9 gauge with ties placed horizontally",Unit,0.008,1.8,"Reinforcement Components, steel bars",0.785,0.837,"Rebar - fabricated, Carbon Leadership Forum benchmark, ASTM A615, ASTM A706, 7850 kg/m3 (Concrete Reinforcing Steel Institute (CRSI))"
27
+ 26,masonry #5 and #6 reinforcing bars placed vertically,Unit,0.43,15.18,"Reinforcement Components, steel bars",38.911,25.115,"Rebar - fabricated, Carbon Leadership Forum benchmark, ASTM A615, ASTM A706, 7850 kg/m3 (Concrete Reinforcing Steel Institute (CRSI))"
28
+ 27,"Control joint, PVC",Unit,0.05,0.05,"Construction Sealants, exterior",0.036,0.39,"Resinous components for structural strengthening, sealing and bonding, 1650 kg/m3, Sikadur-30 (Sika Canada)"
29
+ 28,"Grout, 8"" thick including pumping",Unit,0.188,487.0,"Concrete Grouts, nonmetallic",177.368,157.496,Average
30
+ 29,"XPS, 25 PSI, 3"" RSI 2.64 modified to 3.75"" RSI 3.33",Unit,1.0,0.09525,"Slab and Board Thermal Insulation, extruded polystyrene",173.407,17.155,Average
31
+ 30,"fibreglass batts, 3.5 in thick RSI2.29",Unit,1.0,0.0889,"Blanket Thermal Insulation, fiberglass",7.7,8.116,Average
32
+ 31,"80 ton erection crane, truck mounted",Unit,0.000116,,,0.0,0.0,
33
+ 32,"C.I.P. forms, wood to 10 inches high, including erecting, bracing, stripping cleaning",Unit,0.24,,,0.0,0.0,
34
+ 33,"Form aligner for C.I.P. footing forms, material only",Unit,0.056,,,0.0,0.0,
35
+ 34,"Slab lifting inserts, galvanized, 1"" diameter by 10"" high material only",Unit,8e-05,,,0.0,0.0,
36
+ 35,"Welded wire fabric sheets 6""x6"" 42 lbs per Ft2, excludes accessories",Unit,0.02,2.05,"Reinforcement Components, welded wire fabric",2.754,6.406,"Rebar - fabricated, Carbon Leadership Forum benchmark, ASTM A615, ASTM A706, 7850 kg/m3 (Concrete Reinforcing Steel Institute (CRSI))"
37
+ 36,"Structural concrete, 3000 PSI, 6"" thick includes, levelling, excludes additives and treatment",Unit,0.0125,360.0,Structural Concrete,53.666,103.28,Average
38
+ 37,"Concrete surface treatment, sprayed membrane compound",Unit,0.01,1.0,"Floor Treatment Products, concrete sealer",1.201,1.878,"Concrete waterproofer, 0.162 kg/m2, 980 N/A White (Behr Process LLC)"
39
+ 38,"Tilt-up panel release agent, 1 gal/700ft2",Unit,0.000285,,,0.0,0.0,
40
+ 39,"Angle framing structural steel, field fabricated",Unit,0.19,1.23,"Ferrous Metal Rigid Profiles, structural steel",6.916,8.537,"Fabricated hot-rolled structural steel sections, unpainted, 7800 kg/m3 (487 lb/ft3) (CISC)"
41
+ 40,"XPS, 25 PSI, 2"" RSI 1.76",Unit,1.0,0.05,"Slab and Board Thermal Insulation, extruded polystyrene",82.734,6.69,Average
42
+ 41,"Precast panel, 4 ft x 8 ft smooth white face finish, 4 inch thick, includes erection on prepared openings",Unit,1.0,0.114,Precast Structural Concrete,229.943,139.394,"Precast concrete panel for Canadian eastern region, Fly ash 1.74% (Canadian Precast Concrete Institute)"
43
+ 42,"XPS, 25 PSI, 2 sheets of 2"" RSI 1.76 each total 4"" RSI 3.52",Unit,1.0,0.114,"Slab and Board Thermal Insulation, extruded polystyrene",266.981,45.471,Average
44
+ 43,"fibreglass batts, 6 in thick RSI 3.35",Unit,1.0,0.154,"Blanket Thermal Insulation, fiberglass",18.22,9.765,Average
45
+ 44,"C.I.P. forms, plywood to 8ft high, including erecting, bracing, stripping cleaning",Unit,2.0,,,0.0,0.0,
46
+ 45,"Reinforcing Steel, #3 to #7, includes labour for accessories, but excludes accessories",Unit,0.000376,12.0,"Reinforcement Components, steel bars",12.977,28.483,"Rebar - fabricated, Carbon Leadership Forum benchmark, ASTM A615, ASTM A706, 7850 kg/m3 (Concrete Reinforcing Steel Institute (CRSI))"
47
+ 46,"Structural concrete, 3000 PSI, 6"" thick includes pumping, levelling, consolidation, excludes additives and treatment",Unit,0.018,360.0,Structural Concrete,220.485,216.785,Average
48
+ 47,"Concrete finishing, surface treatment, patching, tie break-off",Unit,2.0,,,0.0,0.0,
49
+ 48,"Steel siding, factory panel, galvanized, 22 gauge, colored 1 side and baked enamal exterior finish, includes 2 in. polystyrene modified to 3"" PS",Unit,1.0,1.0,"Exterior Wall Cladding, insulated metal panel",56.618,97.472,Average
50
+ 49,"fibreglass batts, 3.5 in thick RSI2.29 modified to 5 inch batt RSI 3.05",Unit,1.0,0.127,"Blanket Thermal Insulation, fiberglass",8.528,10.525,Average
51
+ 50,"Spandrel glass 3/8"" plate",Unit,1.0,1.0,"Solid Sheets, glass",79.71,137.458,"Argon gas filled insulating glass unit (IGU) with tempered glass panes, double glazed, 4-16-4, 20 kg/m2 (One Click LCA)"
52
+ 51,Aluminum panel with 2 inches fibreglass,Unit,1.0,2.0,,187.757,298.64,
53
+ 52,"22 gauge sheet metal galvanized with 2"" fibreglass, polyvinyl exterior finish",Unit,1.0,3.0,,99.614,103.097,
54
+ 53,"foil face fibreglass batts, 6 "" thick, 15"" wide, RSI 3.52",Unit,1.0,0.152,"Blanket Thermal Insulation, fiberglass",13.367,14.024,Average
55
+ 54,"0.5"" Isoboard, 4 x 8 sheet, foil faced (RSI 0.48)",Unit,1.0,0.386,"Slab and Board Thermal Insulation, extruded polystyrene",14.608,9.459,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
56
+ 55,"XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.5"" sheets: total 5"" RSI 4.4",Unit,1.0,0.127,"Slab and Board Thermal Insulation, extruded polystyrene",152.454,282.183,Average
57
+ 56,"Isoboard, 1"" thick, RSI .98",Unit,1.0,0.0254,"Slab and Board Thermal Insulation, extruded polystyrene",46.973,43.565,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
58
+ 57,"XPS, 25 PSI, 2"" RSI 1.76",Unit,1.0,0.05,"Slab and Board Thermal Insulation, extruded polystyrene",221.524,128.215,Average
59
+ 58,"XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.25"" sheets RSI 4",Unit,1.0,0.114,"Slab and Board Thermal Insulation, extruded polystyrene",314.85,205.514,Average
60
+ 59,"XPS, 25 PSI, 2"" RSI 1.76 modified to 3 x 2"" sheets RSI 5.28",Unit,1.0,0.154,"Slab and Board Thermal Insulation, extruded polystyrene",535.45,747.559,Average
61
+ 60,"fibreglass batts, 6 in thick RSI3.35",Unit,1.0,0.154,"Blanket Thermal Insulation, fiberglass",2.074,17.015,Average
62
+ 61,"Polyurethane foam lining of spandrel panel, 1 "" RSI 1.14",Unit,1.0,0.0254,"Slab and Board Thermal Insulation, urethane",9.12,7.264,Average
63
+ 62,"Polyurethane foam lining of spandrel panel, 1 "" RSI 1.14",Unit,1.0,0.0254,"Slab and Board Thermal Insulation, urethane",6.456,8.503,Average
64
+ 63,"Isoboard, 1.5"" thick, RSI 1.38",Unit,1.0,0.0381,"Slab and Board Thermal Insulation, extruded polystyrene",31.605,11.477,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
65
+ 64,"Polyurethane Foam 4.5"" thick, RSI 5.15 modifed to 5"" foaming RSI 5.67",Unit,1.0,0.127,"Slab and Board Thermal Insulation, urethane",50.019,44.506,Average
66
+ 65,"XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.5"" sheets: total 5"" RSI 4.4",Unit,1.0,0.127,"Slab and Board Thermal Insulation, extruded polystyrene",123.637,583.983,Average
67
+ 66,"Polyurethane foam lining of spandrel panel, 2 "" RSI 2.2",Unit,1.0,0.0508,"Slab and Board Thermal Insulation, urethane",5.411,18.3,Average
68
+ 67,"Isoboard sheathing, 2"" thick RSI 1.93",Unit,1.0,0.05,"Slab and Board Thermal Insulation, extruded polystyrene",70.573,28.131,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
69
+ 68,"Polyurethane Foam 4.5"" thick, RSI 5.15 modified to 5.5"" foaming RSI 6.18",Unit,1.0,0.139,"Slab and Board Thermal Insulation, urethane",24.155,49.128,Average
70
+ 69,"fibreglass batts, 6 in thick RSI 3.34",Unit,1.0,0.154,"Blanket Thermal Insulation, fiberglass",1.529,8.895,Average
71
+ 70,"Isoboard sheathing, 3"" thick RSI 2.88 2 sheets 6"" RSI 5.76",Unit,1.0,0.154,"Slab and Board Thermal Insulation, extruded polystyrene",61.619,112.774,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
72
+ 71,"XPS, 25 PSI, 2"" RSI 1.76 modified to 2 x 2.5"" sheets: total 5"" RSI 4.4",Unit,1.0,0.127,"Slab and Board Thermal Insulation, extruded polystyrene",325.36,254.895,Average
73
+ 72,"Polyurethane foam lining of spandrel panel, 3 "" RSI 3.42",Unit,1.0,0.076,"Slab and Board Thermal Insulation, urethane",21.607,48.124,Average
74
+ 73,"Isoboard 3"" RSI 2.9, modified to 3.75"" sheet RSI 3.63",Unit,1.0,0.095,"Slab and Board Thermal Insulation, extruded polystyrene",28.474,18.556,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
75
+ 74,"gypsumboard, 0.5 in. fire rated, no finish or taping",Unit,1.0,0.0127,"Solid Sheets, gypsum board, fiber, 13 mm",8.0,5.212,"Lightwieight gypsum boards for wall and ceiling, 12.7 mm (1/2 in), 6.5 kg/m2, 2438-4877 x 1219 mm, 1/2 in. Sheetrock ® Brand Ultralight Panels (USG)"
76
+ 75,"Isoboard 3"" RSI 2.9, modified to 4"" sheet RSI 3.85",Unit,1.0,0.1,"Slab and Board Thermal Insulation, extruded polystyrene",4.523,29.213,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
77
+ 76,"Isoboard 4"" RSI 3.87 modified to 2x2.5"" sheets RSI 4.84",Unit,1.0,0.127,"Slab and Board Thermal Insulation, extruded polystyrene",53.408,98.006,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
78
+ 77,"Isoboard 4"" RSI 3.87 modfied to 2 x 2.75"" sheets RSI 5.15",Unit,1.0,0.13,"Slab and Board Thermal Insulation, extruded polystyrene",54.818,60.119,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
79
+ 78,"Polyurethane foam, closed cell, 4"", RSI 4.10 modified to 6""foaming RSI 6.15",Unit,1.0,0.152,"Slab and Board Thermal Insulation, urethane",18.434,35.933,Average
80
+ 79,"Fibreglass Foil Faced 3 "" RSI 2.29",Unit,1.0,0.076,"Blanket Thermal Insulation, fiberglass",0.904,2.343,"Fiberglass insulation in rolls and batts, foil-faced, R = 1 m2/KW, 39.8 mm, 0.644 kg/unit, Foil-faced EcoBatt®, EcoRoll (Knauff Insulation, Albion plant)"
81
+ 80,"XPS, 25 PSI, 3"" RSI 2.64",Unit,1.0,0.076,"Slab and Board Thermal Insulation, extruded polystyrene",272.047,280.221,Average
82
+ 81,"Fibreglass Foil Faced High Density 3 "" RSI 2.64",Unit,1.0,0.076,"Blanket Thermal Insulation, fiberglass",3.492,2.642,"Fiberglass insulation in rolls and batts, foil-faced, R = 1 m2/KW, 39.8 mm, 0.644 kg/unit, Foil-faced EcoBatt®, EcoRoll (Knauff Insulation, Albion plant)"
83
+ 82,"XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52",Unit,1.0,0.101,"Slab and Board Thermal Insulation, extruded polystyrene",108.02,107.441,Average
84
+ 83,"Fibreglass Foil Faced 6 "" RSI 3.7",Unit,1.0,0.152,"Blanket Thermal Insulation, fiberglass",14.268,8.154,"Fiberglass insulation in rolls and batts, foil-faced, R = 1 m2/KW, 39.8 mm, 0.644 kg/unit, Foil-faced EcoBatt®, EcoRoll (Knauff Insulation, Albion plant)"
85
+ 84,"XPS, 25 PSI, 2"" RSI 1.76 modified to 2 sheets 4"" RSI 3.52",Unit,1.0,0.101,"Slab and Board Thermal Insulation, extruded polystyrene",314.019,287.012,Average
86
+ 85,"XPS, 25 PSI, 3"" RSI 2.64 modified to 1x 3"" sheet and 1x 2.25"" sheet RSI 4.63",Unit,1.0,0.133,"Slab and Board Thermal Insulation, extruded polystyrene",630.418,588.993,Average
87
+ 86,"Polyurethance foam, 6"" RSI 5.28",Unit,1.0,0.152,"Slab and Board Thermal Insulation, urethane",42.219,2.693,Average
88
+ 87,"asphalt flood coat, gravel base coated glass-fibre sheet and 3 plies glass fibre felt (type IV) mopped on nailable deck",Unit,0.01,1.0,"Roof Underlayment, rubberized asphalt",18.894,2.128,"Bitumen roofing membrane, hot mopped, M/M, 2.13 lbs/ft2 (Soprema)"
89
+ 88,"plywood underlayment 0.5"" thick",Unit,1.0,0.0127,"Solid Sheets, softwood plywood",10.94,7.68,"Softwood plywood, 477.33 kg/m3 (Canadian Wood Council)"
90
+ 89,"roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI modifed to 1x4"" + 1x1.25"" sheets RSI 4.4",Unit,1.0,0.133,"Slab and Board Thermal Insulation, extruded polystyrene",318.332,570.12,Average
91
+ 90,"Spruce Wood decking, 2 "" thick",Unit,1.0,0.05,"Wood Flooring, engineered factory finished",9.689,5.121,"Planned redwood decking, thickness range: 8 - 22mm, 3.04kg/m2, 380 kg/m3 oven-dry, moisture content < 13% (One Click LCA)"
92
+ 91,"roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI",Unit,1.0,0.101,"Slab and Board Thermal Insulation, extruded polystyrene",81.154,55.33,Average
93
+ 92,"Fibreglassboard, 1-5/16 inches thick RSI 0.92",Unit,1.0,0.007,"Blanket Thermal Insulation, fiberglass",1.878,1.909,"Fiberglass insulation, 44 mm, R = 1 m2K/W, 0.354 kg/m2, PINK Next Gen™ Fiberglas™ Insulation, unfaced (Owens Corning)"
94
+ 93,"Steel decking, open type galvanized, 1.5"" rib depth, 18 gauge",Unit,1.0,10.5,"Structural Roof Decks, metal",55.625,34.06,"Steel roof and floor deck, North America average, 38-76 mm (Steel Deck Institute)"
95
+ 94,"60 ml Single ply EPDM membrane fully adhered to underlayment, 0.4 lb/ft2 no ballast or aggregate topping",Unit,0.01,1.0,"Single Layer Roof Membranes, ethylene propylene diene monomer (EPDM), 60 mil",16.694,5.051,"TPO Single ply waterproofing roof membrane (mechanically fastened), 60 mils: 1.55 kg/m2 (Single Ply Roofing Industry)"
96
+ 95,"Zinc Steel roofing, 28 gauge, .020"" thick, 115 lb/ft2",Unit,0.01,3.99,"Exterior Metal Roof Panels, insulated, 50 mm",11.342,2.31,"Hot-dip galvanized steel sheets, Steel thickness range: 0.4-3.0 mm (0.015-0.12 in), zinc coating: 20 μm (787.4 µin) (0.28kg/m2 / 0.057 lbs/ft2 sheet steel), 100% recycled content (One Click LCA)"
97
+ 96,"Asphalt felt, #15",Unit,1.0,1.0,"Roof Underlayment, organic felt, #15 ",9.136,6.55,"Hot-applied rubberized asphalt membrane, waterproofing, 5.56 mm (219 mils), 6.39 kg/m2 (1.3 lb/ft2), Monolithic Membrane 6125 (MM6125) (Hydrotech Membrane Corp (2023))"
98
+ 97,Plywood underlayment 0.75' thick,Unit,1.0,0.019,"Solid Sheets, softwood plywood",10.796,3.732,"Softwood plywood, 477.33 kg/m3 (Canadian Wood Council)"
99
+ 98,"Premium shingles, Class A, 300-385 lbs/ft2, pneumatic nailer",Unit,0.01,1.0,"Fiberglass Siding, 19 mm",23.596,18.009,"Fiberglass asphalt shingle roofing system, 12.7 kg/m2 (Asphalt Roofing Manufacturers Association (ARMA))"
100
+ 99,"9.5"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 5.28)",Unit,1.0,0.241,"Blanket Thermal Insulation, kraft paper faced fiberglass",26.362,19.333,"Fiberglass batt insulation, kraft faced, 1 m2K/W, 35 mm, 12.03 kg/m3, 0.421 kg/m2 (North American Insulation Manufacturers Association (NAIMA))"
101
+ 100,"Isoboard, 1.5 in thick RSI 1.48",Unit,1.0,0.0381,"Slab and Board Thermal Insulation, extruded polystyrene",16.787,5.456,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
102
+ 101,"12"" thick fibreglass, kraft coated ceiling insulation, 15"" wide blanket (RSI 6.69)",Unit,1.0,0.3,"Blanket Thermal Insulation, kraft paper faced fiberglass",10.648,27.818,"Fiberglass batt insulation, kraft faced, 1 m2K/W, 35 mm, 12.03 kg/m3, 0.421 kg/m2 (North American Insulation Manufacturers Association (NAIMA))"
103
+ 102,"roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI modifed to 1x4"" + 1x2"" sheets RSI 5.28",Unit,1.0,0.152,"Slab and Board Thermal Insulation, extruded polystyrene",237.606,643.136,Average
104
+ 103,"Isoboard, 0.75 in thick RSI .72",Unit,1.0,0.019,"Slab and Board Thermal Insulation, extruded polystyrene",1.461,16.418,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
105
+ 104,"18"" thick fibreglass blown ceiling (RSI 7.9) ",Unit,1.0,0.457,"Loose Fill Thermal Insulation, fiberglass",23.154,25.901,"Fiberglass insulation blow insulation, R = 1m2K/W, 0.47 kg/m2 (Certainteed)"
106
+ 105,"16"" thick fibreglass blown ceiling (RSI 6.7)",Unit,1.0,0.406,"Loose Fill Thermal Insulation, fiberglass",22.845,7.648,"Fiberglass insulation blow insulation, R = 1m2K/W, 0.47 kg/m2 (Certainteed)"
107
+ 106,"roof deck extruded polystyrene, 4"" (RSI 3.52), 25 PSI modifed to 2x4"" sheets RSI 7.04",Unit,1.0,0.203,"Slab and Board Thermal Insulation, extruded polystyrene",317.644,405.72,Average
108
+ 107,"20"" thick fibreglass blown ceiling (RSI 8.63)",Unit,1.0,0.508,"Loose Fill Thermal Insulation, fiberglass",31.87,1.015,"Fiberglass insulation blow insulation, R = 1m2K/W, 0.47 kg/m2 (Certainteed)"
109
+ 108,gypsum wallboard 0.5 in thick,Unit,1.0,1.0,"Solid Sheets, gypsum board, fiber, 13 mm",3.658,1.294,"Lightwieight gypsum boards for wall and ceiling, 12.7 mm (1/2 in), 6.5 kg/m2, 2438-4877 x 1219 mm, 1/2 in. Sheetrock ® Brand Ultralight Panels (USG)"
110
+ 109,"Roof Insulation fastening, 4"" screws",Unit,1.0,0.07,"Mechanical Fasteners for Metal Structures, screws",0.312,0.363,"Fabricated hot-rolled structural steel sections, unpainted, 7800 kg/m3 (487 lb/ft3) (CISC (2022))"
111
+ 110,"C.I.P. forms elevated slab floor hung from steel beams, including shoring, erection, bracing",Unit,1.0,,,0.0,0.0,
112
+ 111,"C.I.P. forms elevated slab edge forms, including shoring, erection, bracing",Unit,0.2,,,0.0,0.0,
113
+ 112,"Reinforcing steel for elevated slabs and ceilings/roofa, grade 60, all assembly and accessories",Unit,0.001275,12.0,"Reinforcement Components, steel bars",16.252,27.173,"Rebar - fabricated, Carbon Leadership Forum benchmark, ASTM A615, ASTM A706, 7850 kg/m3 (Concrete Reinforcing Steel Institute (CRSI))"
114
+ 113,"Structural concrete, 3000 PSI, complete delivered and pum,ped in place",Unit,0.0231,487.2,Structural Concrete,261.325,344.455,Average
115
+ 114,"Concrete surface treatment, curing, sprayed membrane compound",Unit,0.01,0.2,"Floor Treatment Products, concrete sealer",4.698,17.7,"Concrete waterproofer, 0.162 kg/m2, 980 N/A White (Behr Process LLC)"
116
+ 115,"Sprayed fireproofing, vermiculite cement, 0.25""",Unit,1.0,18.9,"Fireproofing Coatings, cementitious",19.058,61.193,"Portland-fly-ash cement, generic, CEM II/A-V, 20% fly ash content (One Click LCA)"
117
+ 116,"Roof Insulation fastening, 4"" screws modifed to 8"" screws",Assembly,1.0,0.14,"Mechanical Fasteners for Metal Structures, screws",0.675,0.631,"Fabricated hot-rolled structural steel sections, unpainted, 7800 kg/m3 (487 lb/ft3) (CISC (2022))"
118
+ 117,"Floor system, light gauge (14 ga.) galvanized steel, ""C"" type joists, 10"" deep, 24"" spacing, 15' span, 116 PSF total load",Unit,0.22,8.0,"Framing Products, metal framing",26.346,16.001,"Steel stud framing for drywall/gypsum plasterboard per sq. meter of wall area (incl. air gaps per m3), C-profile: 6 x 3 inch, gauge 20, 10 ft. height x 12 inch (30 cm) spacing"
119
+ 118,"3/4"" thick CDX plywood subfloor, pneumatic nailed",Unit,1.0,0.019,"Solid Sheets, softwood plywood",17.066,9.629,"Softwood plywood, 477.33 kg/m3 (Canadian Wood Council)"
120
+ 119,"Steel siding, bevelled with vinyl finish, 10"" width",Unit,1.0,2.0,,27.768,3.584,
121
+ 120,"Floor system, 2""x10"" joists, 24"" spacing, 116 PSF total load",Unit,0.00091,0.0147,"Web Beams and Joists, wood joists",3.022,4.378,"Softwood lumber, kiln-dried and planed, 19 mm, 460 kg/m3, 15% moisture content (American Wood Council, Canadian Wood Council)"
122
+ 121,"Isoboard, 1.5 "" 4 x 8 sheet, foil faced (RSI 1.28)",Unit,1.0,0.038,"Slab and Board Thermal Insulation, extruded polystyrene",17.442,29.014,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
123
+ 122,"6"" sprayed polyurethane foam (RSI 6.86) modifed to 9"" foaming RSI 10.3",Unit,1.0,0.228,"Slab and Board Thermal Insulation, urethane",26.832,12.351,Average
124
+ 123,"Concrete forms, wooden, erecting, bracing, stripping, cleaning",Unit,0.03,,,0.0,0.0,
125
+ 124,"Expansion joint, premolded bituminous fiber",Unit,0.22,0.05,"Construction Sealants, exterior",0.475,0.049,"Resinous components for structural strengthening, sealing and bonding, 1650 kg/m3, Sikadur-30 (Sika Canada)"
126
+ 125,"Welded wire, 6 x 6 sheets, 30 lbs/ft2",Unit,0.012,1.46,"Reinforcement Components, welded wire fabric",1.392,4.117,"Rebar - fabricated, Carbon Leadership Forum benchmark, ASTM A615, ASTM A706, 7850 kg/m3 (Concrete Reinforcing Steel Institute (CRSI))"
127
+ 126,"Structural concrete, ready mix 3500 psi, local aggregate, Type 1 Portland cement, no additives",Unit,0.019,487.2,Structural Concrete,306.643,266.018,Average
128
+ 127,"Structural concrete, placing, slab on grade, direct chute, over 6\"" thick, includes leveling ",Unit,0.019,364.8,Structural Concrete,35.648,111.954,Average
129
+ 128,"Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4",Unit,1.0,,,0.0,0.0,
130
+ 129,"Concrete surface treatment, sprayed membrane",Unit,0.01,1.0,"Floor Treatment Products, concrete sealer",12.023,9.159,"Concrete waterproofer, 0.162 kg/m2, 980 N/A White (Behr Process LLC)"
131
+ 130,"Vapur barrier, polyethylene 6 mil",Unit,0.01,1.0,"Vapor Barriers, polyethylene, 6 mil",0.758,5.516,"Polyethylene vapour barrier membrane, 0.15 mm, 0.14 kg/m2 (One Click LCA)"
132
+ 131,"Fine grading, finish grading, small area, to be paved with grader",Unit,0.11,,,0.0,0.0,
133
+ 132,"Fill, gravel fill, compacted, under floor slabs, 4\"" deep",Unit,1.0,0.1,"Dense Fills and Aggregates, granular fill",2.786,0.307,"Aggregate (crushed gravel), generic, dry bulk density, 1600 kg/m3"
134
+ 133,"Isoboard, 38 mm RSI 1.44",Unit,1.0,0.038,"Slab and Board Thermal Insulation, extruded polystyrene",0.95,20.543,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
135
+ 134,"XPS, 3"" 2.64",Unit,1.0,0.076,"Slab and Board Thermal Insulation, extruded polystyrene",63.515,363.292,Average
136
+ 135,"Concrete finishing, fresh concrete flatwork, floors, basic finishing for unspecified flatwork",Unit,1.5,,,0.0,0.0,
137
+ 136,"Washing brick, smooth brick, acid wash",Unit,1.0,,,0.0,0.0,
138
+ 137,"Structural concrete, placing, slab on grade, direct chute, up to 6\"" thick, includes leveling ",Unit,0.025,360.0,Structural Concrete,208.621,174.278,Average
139
+ 138,"Wood framing, partitions, standard & better lumber, 2\"" x 6\"" studs, 16\"" O.C., 10' high, includes single bottom plate and double top plate",Unit,0.1,0.011,Wood Framed Structural Walls,0.37,2.996,"Softwood lumber, kiln-dried and planed, 19 mm, 460 kg/m3, 15% moisture content (American Wood Council, Canadian Wood Council)"
140
+ 139,"Sheet metal flashing, aluminum, flexible, mill finish, .019\"" thick, including up to 4 bends",Unit,0.1,1.0,"Roof Flashings, aluminum",31.566,12.817,"Galvanized steel panels, trims, flashings and flat sheets from electric arc furnace (EAF), 5.89 kg/m2 (AEP Span)"
141
+ 140,"Pre-formed joint seals, backer rod, polyethylene, 1/4\"" dia""",Unit,0.001,0.05,"Construction Sealants, elastomeric",0.092,0.115,"Resinous components for structural strengthening, sealing and bonding, 1650 kg/m3, Sikadur-30 (Sika Canada)"
142
+ 141,"Joint sealants, caulking and sealants, butyl based, bulk, 1/4\"" x 1/2\""",Unit,0.125,0.05,Joint Fillers,0.444,0.042,"Resinous components for structural strengthening, sealing and bonding, 1650 kg/m3, Sikadur-30 (Sika Canada)"
143
+ 142,"Structural concrete, placing, walls, pumped, 8\"" thick, includes leveling (strike off) & consolidation",Unit,0.018,487.2,Structural Concrete,352.56,246.584,Average
144
+ 143,"Concrete finishing, specified Random Access Floors ACI Classes 1, 2, 3 & 4,",Unit,1.0,,,0.0,0.0,
145
+ 144,"Structural concrete, placing, elevated slab, pumped, 6\"" to 10\"" thick, includes leveling (strike off) & consolidation",Unit,0.625,487.2,Structural Concrete,32.713,207.482,Average
146
+ 145,Installation of 14 gauge steel floor joist to beams/headers,Unit,0.3,,,0.0,0.0,
147
+ 146,"Metal Door 20 gauge, includes hardware",Unit,0.0476,8.2,"Metal Doors, exterior",80.358,17.29,"Steel door frame, 1.51 mm, depth 5.75 inch, 21.3 kg/unit (Steel Door Institute, Deansteel, Mesker, MPI, HMX, Hollow metal on demand)"
148
+ 147,"Aluminum Commercial Entrance pair of 2'-6"" x 7'-0"" includes hardware",Unit,0.02857,9.38,"Aluminum Doors, Storm",99.156,252.776,"Aluminium framed glass door, swing type, 30.87 kg/m2, 4487 Series Swing Door, 458T Series Swing Door (Toro Aluminum)"
149
+ 148,"Fibreglass Door, 3'-0"" x 7'-0', includes hardware",Unit,0.0476,14.75,Fiberglass Composite Doors,22.841,8.784,"Fiberglass reinforced PE door, 2.68m2/unit, FRP (ASSA ABLOY)"
150
+ 149,"Steel Overhead Rolling Door, 10'-0 x 10'-0' includes hardware",Unit,0.01,21.53,"Overhead Metal Doors, roller shutter",335.479,318.393,"Residental garage overhead sectional door with PUR core, 2500x2125 mm, 123 kg/unit (One Click LCA)"
151
+ 150,"XPS, 25 PSI, 1"" RSI 0.88",Unit,1.0,0.025,"Slab and Board Thermal Insulation, extruded polystyrene",76.831,111.44,Average
152
+ 151,"XPS, 25 PSI, 1"" RSI 0.88 modifed to 1.5"" sheet RSI 1.32",Unit,1.0,0.0381,"Slab and Board Thermal Insulation, extruded polystyrene",57.575,44.58,Average
153
+ 152,"Isoboard, 1"" RSI 1.94 modified to 2"" RSI 3.88",Unit,1.0,0.0508,"Slab and Board Thermal Insulation, extruded polystyrene",2.951,33.731,"Polyisocyanurate (PIR) roof insulation boards, coated glass faced (CGF), 0.941kg/m2 (2.07 lb/m2), 25 mm (0.984 in) (Atlas Roofing Corporation, Carlisle Construction Materials, Firestone Building Products, GAF, IKO, Johns Manville, Rmax - A Sika Brand, Soprema, Inc. (USA)) "
154
+ 153,"Fibreglasboard 1"" RSI 0.69",Unit,1.0,0.025,"Blanket Thermal Insulation, fiberglass",9.548,4.715,"Fiberglass insulation board, R = 1m2K/W, 45.3 mm, 2.61 kg/m2, 57.62 kg/m3 (NAIMA)"
155
+ 154,10 inch fibreglass insulation RSI 5.86,Unit,1.0,0.254,"Blanket Thermal Insulation, fiberglass",8.638,3.197,"Fiberglass insulation, 44 mm, R = 1 m2K/W, 0.354 kg/m2, PINK Next Gen™ Fiberglas™ Insulation, unfaced (Owens Corning)"
156
+ 155,"Fibreglass Foil Faced 6 "" RSI 3.7 batts, 2 batts installed, modifed to 2 6"" batts back to back RSI 7.4",Unit,1.0,0.304,"Blanket Thermal Insulation, fiberglass",16.482,25.675,"Fiberglass insulation in rolls and batts, foil-faced, R = 1 m2/KW, 39.8 mm, 0.644 kg/unit, Foil-faced EcoBatt®, EcoRoll (Knauff Insulation, Albion plant)"
157
+ 156,concrete cutting through wall per inch of thickness,Unit,1.0,,,0.0,0.0,
158
+ 157,"galvanized LB studs, 16 ga x 6\"" W studs 16\"" O.C. x 10' H, incl galvanized top & bottom track, excl openings, headers, beams, bracing & bridging",Unit,0.1,4.3,"Ferrous Metal Rigid Profiles, galvanized steel stud",45.591,33.525,"Galvanized steel stud framing profiles per m2 (air gap included), UD and CD profiles included, wing width: 6 mm, flange width:50 mm, steel thicnkess:0.6 mm (23 gauge), 450 mm spacing, 2.4 kg/m2 (One Click LCA)"
159
+ 158,"XPS, 3/4"" RSI 0.501",Unit,1.0,0.019,"Slab and Board Thermal Insulation, extruded polystyrene",23.296,23.889,Average
160
+ 159,"fibreglass batts, 6 in thick RSI 3.7",Unit,1.0,0.152,"Blanket Thermal Insulation, fiberglass",6.967,10.569,Average
161
+ 160,"Fibreglass Foil Faced 6 "" RSI 3.7 batts",Unit,1.0,0.152,"Blanket Thermal Insulation, fiberglass",3.102,2.729,"Fiberglass insulation in rolls and batts, foil-faced, R = 1 m2/KW, 39.8 mm, 0.644 kg/unit, Foil-faced EcoBatt®, EcoRoll (Knauff Insulation, Albion plant)"
162
+ 161,"Kraft faced fiberglass, 3-1/2"" thick, 23"" wide, RSI1.93",Unit,1.0,0.0889,"Blanket Thermal Insulation, kraft paper faced fiberglass",1.34,7.225,"Fiberglass batt insulation, kraft faced, 1 m2K/W, 35 mm, 12.03 kg/m3, 0.421 kg/m2 (North American Insulation Manufacturers Association (NAIMA))"
163
+ 162,"Kraft faced fiberglass, 3-1/2"" thick, 23"" wide, RSI2.29",Unit,1.0,0.0889,"Blanket Thermal Insulation, kraft paper faced fiberglass",6.593,6.891,"Fiberglass batt insulation, kraft faced, 1 m2K/W, 35 mm, 12.03 kg/m3, 0.421 kg/m2 (North American Insulation Manufacturers Association (NAIMA))"
164
+ 163,"Polyurethane Foam 4.5"" thick, RSI5.72",Unit,1.0,0.0114,"Slab and Board Thermal Insulation, urethane",10.851,15.122,Average
@@ -0,0 +1,121 @@
1
+ construction_glazing_id,construction_type_name,author,old_type_code,intended_surface_type,fenestration_type,type_index,climate_zone,u_w_per_m2_k,description,material_glazing_id_layers,component,surface_type
2
+ 1,BTAP-ExteriorWindow-FixedWindow-1,BTAP,1,ExteriorWindow,FixedWindow,1,Zone 4,2.4,Fixed window,1,"Windows, aluminum, awning, standard glass, 4'-5"" x 5'-3""
3
+ ",GLAZING
4
+ 2,BTAP-ExteriorWindow-FixedWindow-1,BTAP,1,ExteriorWindow,FixedWindow,1,Zone 5,2.2,Fixed window,9,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
5
+ ",GLAZING
6
+ 3,BTAP-ExteriorWindow-FixedWindow-1,BTAP,1,ExteriorWindow,FixedWindow,1,Zone 6,2.2,Fixed window,9,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
7
+ ",GLAZING
8
+ 4,BTAP-ExteriorWindow-FixedWindow-1,BTAP,1,ExteriorWindow,FixedWindow,1,Zone 7A,2.2,Fixed window,9,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
9
+ ",GLAZING
10
+ 5,BTAP-ExteriorWindow-FixedWindow-1,BTAP,1,ExteriorWindow,FixedWindow,1,Zone 7B,2.2,Fixed window,9,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
11
+ ",GLAZING
12
+ 6,BTAP-ExteriorWindow-FixedWindow-1,BTAP,1,ExteriorWindow,FixedWindow,1,Zone 8,1.6,Fixed window,17,"Windows, aluminum, double hung, insul. glass, 3'-0"" x 4'-0""
13
+ ",GLAZING
14
+ 7,BTAP-ExteriorWindow-FixedWindow-2,BTAP,4,ExteriorWindow,FixedWindow,2,Zone 4,2.4,Mall Front Fixed Panels (window wall),4,"fixed mall front panels, aluminum finish 48' x 9' opening, zero frame thermal break
15
+ ",GLAZING
16
+ 8,BTAP-ExteriorWindow-FixedWindow-2,BTAP,4,ExteriorWindow,FixedWindow,2,Zone 5,2.2,Mall Front Fixed Panels (window wall),12,"fixed mall front panels, aluminum finish 48' x 9' opening
17
+ ",GLAZING
18
+ 9,BTAP-ExteriorWindow-FixedWindow-2,BTAP,4,ExteriorWindow,FixedWindow,2,Zone 6,2.2,Mall Front Fixed Panels (window wall),12,"fixed mall front panels, aluminum finish 48' x 9' opening
19
+ ",GLAZING
20
+ 10,BTAP-ExteriorWindow-FixedWindow-2,BTAP,4,ExteriorWindow,FixedWindow,2,Zone 7A,2.2,Mall Front Fixed Panels (window wall),12,"fixed mall front panels, aluminum finish 48' x 9' opening
21
+ ",GLAZING
22
+ 11,BTAP-ExteriorWindow-FixedWindow-2,BTAP,4,ExteriorWindow,FixedWindow,2,Zone 7B,2.2,Mall Front Fixed Panels (window wall),12,"fixed mall front panels, aluminum finish 48' x 9' opening
23
+ ",GLAZING
24
+ 12,BTAP-ExteriorWindow-FixedWindow-2,BTAP,4,ExteriorWindow,FixedWindow,2,Zone 8,1.6,Mall Front Fixed Panels (window wall),20,"triple glazed U= 1.6 W/m2-K, fixed mall front panels, aluminum finish 48' x 9' opening
25
+ ",GLAZING
26
+ 13,BTAP-ExteriorWindow-OperableWindow-3,BTAP,5,ExteriorWindow,OperableWindow,3,Zone 4,2.4,Aluminum Commercial Operable Sliders,5,"aluminum window: stock 5'x3' including framing and insulated glazing, zero frame thermal break
27
+ ",GLAZING
28
+ 14,BTAP-ExteriorWindow-OperableWindow-3,BTAP,5,ExteriorWindow,OperableWindow,3,Zone 5,2.2,Aluminum Commercial Operable Sliders,13,"aluminum window: stock 5'x3' including framing and insulated glazing
29
+ ",GLAZING
30
+ 15,BTAP-ExteriorWindow-OperableWindow-3,BTAP,5,ExteriorWindow,OperableWindow,3,Zone 6,2.2,Aluminum Commercial Operable Sliders,13,"aluminum window: stock 5'x3' including framing and insulated glazing
31
+ ",GLAZING
32
+ 16,BTAP-ExteriorWindow-OperableWindow-3,BTAP,5,ExteriorWindow,OperableWindow,3,Zone 7A,2.2,Aluminum Commercial Operable Sliders,13,"aluminum window: stock 5'x3' including framing and insulated glazing
33
+ ",GLAZING
34
+ 17,BTAP-ExteriorWindow-OperableWindow-3,BTAP,5,ExteriorWindow,OperableWindow,3,Zone 7B,2.2,Aluminum Commercial Operable Sliders,13,"aluminum window: stock 5'x3' including framing and insulated glazing
35
+ ",GLAZING
36
+ 18,BTAP-ExteriorWindow-OperableWindow-3,BTAP,5,ExteriorWindow,OperableWindow,3,Zone 8,1.6,Aluminum Commercial Operable Sliders,21,"triple glazed U= 1.6 W/m2-K, aluminum window: stock 5'x3' including framing and insulated glazing
37
+ ",GLAZING
38
+ 19,BTAP-ExteriorWindow-FixedWindow-4,BTAP,6,ExteriorWindow,FixedWindow,4,Zone 4,2.4,Vinyl Commercial Picture Windows,6,"Windows, aluminum, awning, standard glass, 4'-5"" x 5'-3""
39
+ ",GLAZING
40
+ 20,BTAP-ExteriorWindow-FixedWindow-4,BTAP,6,ExteriorWindow,FixedWindow,4,Zone 5,2.2,Vinyl Commercial Picture Windows,14,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
41
+ ",GLAZING
42
+ 21,BTAP-ExteriorWindow-FixedWindow-4,BTAP,6,ExteriorWindow,FixedWindow,4,Zone 6,2.2,Vinyl Commercial Picture Windows,14,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
43
+ ",GLAZING
44
+ 22,BTAP-ExteriorWindow-FixedWindow-4,BTAP,6,ExteriorWindow,FixedWindow,4,Zone 7A,2.2,Vinyl Commercial Picture Windows,14,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
45
+ ",GLAZING
46
+ 23,BTAP-ExteriorWindow-FixedWindow-4,BTAP,6,ExteriorWindow,FixedWindow,4,Zone 7B,2.2,Vinyl Commercial Picture Windows,14,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
47
+ ",GLAZING
48
+ 24,BTAP-ExteriorWindow-FixedWindow-4,BTAP,6,ExteriorWindow,FixedWindow,4,Zone 8,1.6,Vinyl Commercial Picture Windows,22,"Windows, aluminum, double hung, insul. glass, 3'-0"" x 4'-0""
49
+ ",GLAZING
50
+ 25,BTAP-ExteriorWindow-OperableWindow-5,BTAP,7,ExteriorWindow,OperableWindow,5,Zone 4,2.4,Vinyl-Wood Clad Commercial Casement Windows,7,"6' x 4' picture with insulating glass, 2 lites, low E, finished extensions and jambs, zero frame thermal break
51
+ ",GLAZING
52
+ 26,BTAP-ExteriorWindow-OperableWindow-5,BTAP,7,ExteriorWindow,OperableWindow,5,Zone 5,2.2,Vinyl-Wood Clad Commercial Casement Windows,15,"6' x 4' picture with insulating glass, 2 lites, low E, finished extensions and jambs
53
+ ",GLAZING
54
+ 27,BTAP-ExteriorWindow-OperableWindow-5,BTAP,7,ExteriorWindow,OperableWindow,5,Zone 6,2.2,Vinyl-Wood Clad Commercial Casement Windows,15,"6' x 4' picture with insulating glass, 2 lites, low E, finished extensions and jambs
55
+ ",GLAZING
56
+ 28,BTAP-ExteriorWindow-OperableWindow-5,BTAP,7,ExteriorWindow,OperableWindow,5,Zone 7A,2.2,Vinyl-Wood Clad Commercial Casement Windows,15,"6' x 4' picture with insulating glass, 2 lites, low E, finished extensions and jambs
57
+ ",GLAZING
58
+ 29,BTAP-ExteriorWindow-OperableWindow-5,BTAP,7,ExteriorWindow,OperableWindow,5,Zone 7B,2.2,Vinyl-Wood Clad Commercial Casement Windows,15,"6' x 4' picture with insulating glass, 2 lites, low E, finished extensions and jambs
59
+ ",GLAZING
60
+ 30,BTAP-ExteriorWindow-OperableWindow-5,BTAP,7,ExteriorWindow,OperableWindow,5,Zone 8,1.6,Vinyl-Wood Clad Commercial Casement Windows,23,"triple glazed U= 1.6 W/m2-K, 6' x 4' picture with insulating glass, 2 lites, low E, finished extensions and jambs
61
+ ",GLAZING
62
+ 31,BTAP-ExteriorWindow-FixedWindow-6,BTAP,8,ExteriorWindow,FixedWindow,6,Zone 4,2.4,Aluminum Commercial Picture Windows,8,"Windows, aluminum, awning, standard glass, 4'-5"" x 5'-3""
63
+ ",GLAZING
64
+ 32,BTAP-ExteriorWindow-FixedWindow-6,BTAP,8,ExteriorWindow,FixedWindow,6,Zone 5,2.2,Aluminum Commercial Picture Windows,16,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
65
+ ",GLAZING
66
+ 33,BTAP-ExteriorWindow-FixedWindow-6,BTAP,8,ExteriorWindow,FixedWindow,6,Zone 6,2.2,Aluminum Commercial Picture Windows,16,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
67
+ ",GLAZING
68
+ 34,BTAP-ExteriorWindow-FixedWindow-6,BTAP,8,ExteriorWindow,FixedWindow,6,Zone 7A,2.2,Aluminum Commercial Picture Windows,16,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
69
+ ",GLAZING
70
+ 35,BTAP-ExteriorWindow-FixedWindow-6,BTAP,8,ExteriorWindow,FixedWindow,6,Zone 7B,2.2,Aluminum Commercial Picture Windows,16,"Windows, aluminum, awning, insulated glass, 4'-5"" x 5'-3""
71
+ ",GLAZING
72
+ 36,BTAP-ExteriorWindow-FixedWindow-6,BTAP,8,ExteriorWindow,FixedWindow,6,Zone 8,1.6,Aluminum Commercial Picture Windows,24,"Windows, aluminum, double hung, insul. glass, 3'-0"" x 4'-0""
73
+ ",GLAZING
74
+ 37,BTAP-GlassDoor-GlazedDoor-1,BTAP,2,GlassDoor,GlazedDoor,1,Zone 4,2.4,"Sliding Glass, Aluminum Patio Door",2,"6' x 7' aluminum patio, tempered glass, zero frame thermal break
75
+ ",GLAZING
76
+ 38,BTAP-GlassDoor-GlazedDoor-1,BTAP,2,GlassDoor,GlazedDoor,1,Zone 5,2.2,"Sliding Glass, Aluminum Patio Door",10,"6' x 7' aluminum patio, tempered glass
77
+ ",GLAZING
78
+ 39,BTAP-GlassDoor-GlazedDoor-1,BTAP,2,GlassDoor,GlazedDoor,1,Zone 6,2.2,"Sliding Glass, Aluminum Patio Door",10,"6' x 7' aluminum patio, tempered glass
79
+ ",GLAZING
80
+ 40,BTAP-GlassDoor-GlazedDoor-1,BTAP,2,GlassDoor,GlazedDoor,1,Zone 7A,2.2,"Sliding Glass, Aluminum Patio Door",10,"6' x 7' aluminum patio, tempered glass
81
+ ",GLAZING
82
+ 41,BTAP-GlassDoor-GlazedDoor-1,BTAP,2,GlassDoor,GlazedDoor,1,Zone 7B,2.2,"Sliding Glass, Aluminum Patio Door",10,"6' x 7' aluminum patio, tempered glass
83
+ ",GLAZING
84
+ 42,BTAP-GlassDoor-GlazedDoor-1,BTAP,2,GlassDoor,GlazedDoor,1,Zone 8,1.6,"Sliding Glass, Aluminum Patio Door",18,"triple glazed U= 1.6 W/m2-K, 6' x 7' aluminum patio, tempered glass
85
+ ",GLAZING
86
+ 43,BTAP-GlassDoor-GlazedDoor-2,BTAP,3,GlassDoor,GlazedDoor,2,Zone 4,2.4,Sliding Entrance Aluminum Doors,11,"entrance, door 5'x7', opening 12'x7'-6', electric operator
87
+ ",GLAZING
88
+ 44,BTAP-GlassDoor-GlazedDoor-2,BTAP,3,GlassDoor,GlazedDoor,2,Zone 5,2.2,Sliding Entrance Aluminum Doors,11,"entrance, door 5'x7', opening 12'x7'-6', electric operator
89
+ ",GLAZING
90
+ 45,BTAP-GlassDoor-GlazedDoor-2,BTAP,3,GlassDoor,GlazedDoor,2,Zone 6,2.2,Sliding Entrance Aluminum Doors,11,"entrance, door 5'x7', opening 12'x7'-6', electric operator
91
+ ",GLAZING
92
+ 46,BTAP-GlassDoor-GlazedDoor-2,BTAP,3,GlassDoor,GlazedDoor,2,Zone 7A,2.2,Sliding Entrance Aluminum Doors,11,"entrance, door 5'x7', opening 12'x7'-6', electric operator
93
+ ",GLAZING
94
+ 47,BTAP-GlassDoor-GlazedDoor-2,BTAP,3,GlassDoor,GlazedDoor,2,Zone 7B,2.2,Sliding Entrance Aluminum Doors,11,"entrance, door 5'x7', opening 12'x7'-6', electric operator
95
+ ",GLAZING
96
+ 48,BTAP-GlassDoor-GlazedDoor-2,BTAP,3,GlassDoor,GlazedDoor,2,Zone 8,1.6,Sliding Entrance Aluminum Doors,19,"triple glazed U= 1.6 W/m2-K, entrance, door 5'x7', opening 12'x7'-6', electric operator
97
+ ",GLAZING
98
+ 49,BTAP-Skylight-1,BTAP,1,Skylight,PlasticSkylightwithCurb,1,Zone 4,2.4,Plastic Skylight,28,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
99
+ ",SKYLIGHT
100
+ 50,BTAP-Skylight-1,BTAP,1,Skylight,PlasticSkylightwithCurb,1,Zone 5,2.4,Plastic Skylight,28,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
101
+ ",SKYLIGHT
102
+ 51,BTAP-Skylight-1,BTAP,1,Skylight,PlasticSkylightwithCurb,1,Zone 6,2.4,Plastic Skylight,28,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
103
+ ",SKYLIGHT
104
+ 52,BTAP-Skylight-1,BTAP,1,Skylight,PlasticSkylightwithCurb,1,Zone 7A,2.4,Plastic Skylight,28,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
105
+ ",SKYLIGHT
106
+ 53,BTAP-Skylight-1,BTAP,1,Skylight,PlasticSkylightwithCurb,1,Zone 7B,2.4,Plastic Skylight,28,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
107
+ ",SKYLIGHT
108
+ 54,BTAP-Skylight-1,BTAP,1,Skylight,PlasticSkylightwithCurb,1,Zone 8,1.6,Plastic Skylight,26,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
109
+ ",SKYLIGHT
110
+ 55,BTAP-Skylight-2,BTAP,2,Skylight,GlassSkylightwithCurb,2,Zone 4,2.4,Glass Skylight,27,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
111
+ ",SKYLIGHT
112
+ 56,BTAP-Skylight-2,BTAP,2,Skylight,GlassSkylightwithCurb,2,Zone 5,2.4,Glass Skylight,27,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
113
+ ",SKYLIGHT
114
+ 57,BTAP-Skylight-2,BTAP,2,Skylight,GlassSkylightwithCurb,2,Zone 6,2.4,Glass Skylight,27,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
115
+ ",SKYLIGHT
116
+ 58,BTAP-Skylight-2,BTAP,2,Skylight,GlassSkylightwithCurb,2,Zone 7A,2.4,Glass Skylight,27,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
117
+ ",SKYLIGHT
118
+ 59,BTAP-Skylight-2,BTAP,2,Skylight,GlassSkylightwithCurb,2,Zone 7B,2.4,Glass Skylight,27,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
119
+ ",SKYLIGHT
120
+ 60,BTAP-Skylight-2,BTAP,2,Skylight,GlassSkylightwithCurb,2,Zone 8,1.6,Glass Skylight,25,"Skylights, non venting, insulated, plexiglass dome with curb mount, 46"" x 46""
121
+ ",SKYLIGHT