openstudio-standards 0.8.4 → 0.8.5.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.osm +30 -30
- data/data/geometry/ASHRAECourthouse.osm +22 -22
- data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
- data/data/geometry/DEER_Asm.osm +1 -1
- data/data/geometry/DEER_ECC.osm +1 -1
- data/data/geometry/DEER_EPr.osm +1 -1
- data/data/geometry/DEER_ERC.osm +1 -1
- data/data/geometry/DEER_ESe.osm +1 -1
- data/data/geometry/DEER_EUn.osm +1 -1
- data/data/geometry/DEER_Hsp.osm +1 -1
- data/data/geometry/DEER_Htl.osm +1 -1
- data/data/geometry/DEER_MBT.osm +1 -1
- data/data/geometry/DEER_MFm.osm +1 -1
- data/data/geometry/DEER_Nrs.osm +1 -1
- data/data/geometry/DEER_OfL.osm +1 -1
- data/data/geometry/DEER_OfS.osm +1 -1
- data/data/geometry/DEER_RFF.osm +1 -1
- data/data/geometry/DEER_RSD.osm +1 -1
- data/data/geometry/DEER_Rt3.osm +1 -1
- data/data/geometry/DEER_RtS.osm +1 -1
- data/data/standards/export_OpenStudio_libraries.rb +2 -3
- data/data/standards/test_performance_expected_dd_results.csv +42 -42
- data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
- data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
- data/lib/openstudio-standards/btap/activity.rb +480 -0
- data/lib/openstudio-standards/btap/attributes.rb +166 -0
- data/lib/openstudio-standards/btap/bridging.rb +561 -1402
- data/lib/openstudio-standards/btap/btap.rb +4 -2
- data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
- data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
- data/lib/openstudio-standards/btap/{costing/common_paths.rb → common_paths.rb} +14 -11
- data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
- data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
- data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting.csv +59 -59
- data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_hvac.csv +1019 -1032
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +3 -7
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +1 -5
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +5 -4
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +1 -1
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +112 -181
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +4 -4
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +2 -1
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +3 -3
- data/lib/openstudio-standards/btap/costing/test_list.txt +15 -17
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +10 -9
- data/lib/openstudio-standards/btap/geometry.rb +86 -6
- data/lib/openstudio-standards/btap/structure.rb +657 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
- data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
- data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
- data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
- data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
- data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
- data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
- data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
- data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
- data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
- data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
- data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
- data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
- data/lib/openstudio-standards/hvac/components/component.rb +39 -0
- data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
- data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
- data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
- data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
- data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
- data/lib/openstudio-standards/hvac/conversions.rb +222 -0
- data/lib/openstudio-standards/hvac/curves.rb +192 -0
- data/lib/openstudio-standards/hvac/helpers.rb +357 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
- data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
- data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
- data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
- data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
- data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
- data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
- data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
- data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
- data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
- data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
- data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
- data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
- data/lib/openstudio-standards/standards/Standards.Model.rb +6 -11
- data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
- data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
- data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
- data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +19 -10
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +69 -92
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +18 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +5 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +2 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +30 -141
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +233 -112
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
- data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +16 -4
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +65 -42
- data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
- data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/stat_file.rb +2 -2
- data/lib/openstudio-standards.rb +55 -38
- metadata +106 -66
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +0 -61
- data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +0 -1904
- data/lib/openstudio-standards/hvac/components/create.rb +0 -169
- data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
- data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/ConstructionProperties.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/Constructions.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/construction_sets.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/constructions_opaque.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/costs_local_factors.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/hvac_vent_ahu.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting_sets.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/locations.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_glazing.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_lighting.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_opaque.csv +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
|
@@ -33,7 +33,7 @@
|
|
|
33
33
|
"motor_in_airstream_fraction": 1.0,
|
|
34
34
|
"fan_power_minimum_flow_rate_fraction": 0.25,
|
|
35
35
|
"fan_power_minimum_flow_rate_input_method": "Fraction",
|
|
36
|
-
"fan_curve": "Single
|
|
36
|
+
"fan_curve": "Single Zone VAV",
|
|
37
37
|
"notes": null
|
|
38
38
|
},
|
|
39
39
|
{
|
|
@@ -153,7 +153,7 @@
|
|
|
153
153
|
"motor_in_airstream_fraction": 1.0,
|
|
154
154
|
"fan_power_minimum_flow_rate_fraction": 0.25,
|
|
155
155
|
"fan_power_minimum_flow_rate_input_method": "Fraction",
|
|
156
|
-
"fan_curve": "Single
|
|
156
|
+
"fan_curve": "Single Zone VAV",
|
|
157
157
|
"notes": null
|
|
158
158
|
},
|
|
159
159
|
{
|
|
@@ -165,7 +165,7 @@
|
|
|
165
165
|
"motor_in_airstream_fraction": 1.0,
|
|
166
166
|
"fan_power_minimum_flow_rate_fraction": 0.0,
|
|
167
167
|
"fan_power_minimum_flow_rate_input_method": "Fraction",
|
|
168
|
-
"fan_curve": "Multi Zone VAV with
|
|
168
|
+
"fan_curve": "Multi Zone VAV with Fixed Static Pressure Setpoint",
|
|
169
169
|
"notes": null
|
|
170
170
|
},
|
|
171
171
|
{
|
|
@@ -285,7 +285,7 @@
|
|
|
285
285
|
"motor_in_airstream_fraction": 1.0,
|
|
286
286
|
"fan_power_minimum_flow_rate_fraction": 0.25,
|
|
287
287
|
"fan_power_minimum_flow_rate_input_method": "Fraction",
|
|
288
|
-
"fan_curve": "Multi Zone VAV with
|
|
288
|
+
"fan_curve": "Multi Zone VAV with Fixed Static Pressure Setpoint",
|
|
289
289
|
"notes": null
|
|
290
290
|
},
|
|
291
291
|
{
|
|
@@ -309,7 +309,7 @@
|
|
|
309
309
|
"motor_in_airstream_fraction": 1.0,
|
|
310
310
|
"fan_power_minimum_flow_rate_fraction": null,
|
|
311
311
|
"fan_power_minimum_flow_rate_input_method": null,
|
|
312
|
-
"fan_curve": "Multi
|
|
312
|
+
"fan_curve": "Multi Zone VAV with Static Pressure Setpoint Reset",
|
|
313
313
|
"notes": null
|
|
314
314
|
},
|
|
315
315
|
{
|
|
@@ -7875,181 +7875,6 @@
|
|
|
7875
7875
|
"maximum_dependent_variable_output": null,
|
|
7876
7876
|
"notes": "From Reference Buildings"
|
|
7877
7877
|
},
|
|
7878
|
-
{
|
|
7879
|
-
"name": "Multi Zone VAV with Airfoil or Backward Incline riding the curve",
|
|
7880
|
-
"category": "FanEIR-FPLR",
|
|
7881
|
-
"form": "Cubic",
|
|
7882
|
-
"dependent_variable": "PwrRatio",
|
|
7883
|
-
"independent_variable_1": "FlowRatio",
|
|
7884
|
-
"independent_variable_2": null,
|
|
7885
|
-
"coeff_1": 0.1631,
|
|
7886
|
-
"coeff_2": 1.5901,
|
|
7887
|
-
"coeff_3": -0.8817,
|
|
7888
|
-
"coeff_4": 0.1281,
|
|
7889
|
-
"coeff_5": null,
|
|
7890
|
-
"coeff_6": null,
|
|
7891
|
-
"coeff_7": null,
|
|
7892
|
-
"coeff_8": null,
|
|
7893
|
-
"coeff_9": null,
|
|
7894
|
-
"coeff_10": null,
|
|
7895
|
-
"minimum_independent_variable_1": 0.0,
|
|
7896
|
-
"maximum_independent_variable_1": 1.0,
|
|
7897
|
-
"minimum_independent_variable_2": null,
|
|
7898
|
-
"maximum_independent_variable_2": null,
|
|
7899
|
-
"minimum_dependent_variable_output": 0.7,
|
|
7900
|
-
"maximum_dependent_variable_output": null,
|
|
7901
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7902
|
-
},
|
|
7903
|
-
{
|
|
7904
|
-
"name": "Multi Zone VAV with Airfoil or Backward Incline with inlet vanes",
|
|
7905
|
-
"category": "FanEIR-FPLR",
|
|
7906
|
-
"form": "Cubic",
|
|
7907
|
-
"dependent_variable": "PwrRatio",
|
|
7908
|
-
"independent_variable_1": "FlowRatio",
|
|
7909
|
-
"independent_variable_2": null,
|
|
7910
|
-
"coeff_1": 0.9977,
|
|
7911
|
-
"coeff_2": -0.659,
|
|
7912
|
-
"coeff_3": 0.9547,
|
|
7913
|
-
"coeff_4": -0.2936,
|
|
7914
|
-
"coeff_5": null,
|
|
7915
|
-
"coeff_6": null,
|
|
7916
|
-
"coeff_7": null,
|
|
7917
|
-
"coeff_8": null,
|
|
7918
|
-
"coeff_9": null,
|
|
7919
|
-
"coeff_10": null,
|
|
7920
|
-
"minimum_independent_variable_1": 0.0,
|
|
7921
|
-
"maximum_independent_variable_1": 1.0,
|
|
7922
|
-
"minimum_independent_variable_2": null,
|
|
7923
|
-
"maximum_independent_variable_2": null,
|
|
7924
|
-
"minimum_dependent_variable_output": 0.5,
|
|
7925
|
-
"maximum_dependent_variable_output": null,
|
|
7926
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7927
|
-
},
|
|
7928
|
-
{
|
|
7929
|
-
"name": "Multi Zone VAV with Forward Curved fans riding the curve",
|
|
7930
|
-
"category": "FanEIR-FPLR",
|
|
7931
|
-
"form": "Cubic",
|
|
7932
|
-
"dependent_variable": "PwrRatio",
|
|
7933
|
-
"independent_variable_1": "FlowRatio",
|
|
7934
|
-
"independent_variable_2": null,
|
|
7935
|
-
"coeff_1": 0.1224,
|
|
7936
|
-
"coeff_2": 0.612,
|
|
7937
|
-
"coeff_3": 0.5983,
|
|
7938
|
-
"coeff_4": -0.3334,
|
|
7939
|
-
"coeff_5": null,
|
|
7940
|
-
"coeff_6": null,
|
|
7941
|
-
"coeff_7": null,
|
|
7942
|
-
"coeff_8": null,
|
|
7943
|
-
"coeff_9": null,
|
|
7944
|
-
"coeff_10": null,
|
|
7945
|
-
"minimum_independent_variable_1": 0.0,
|
|
7946
|
-
"maximum_independent_variable_1": 1.0,
|
|
7947
|
-
"minimum_independent_variable_2": null,
|
|
7948
|
-
"maximum_independent_variable_2": null,
|
|
7949
|
-
"minimum_dependent_variable_output": 0.3,
|
|
7950
|
-
"maximum_dependent_variable_output": null,
|
|
7951
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7952
|
-
},
|
|
7953
|
-
{
|
|
7954
|
-
"name": "Multi Zone VAV with Forward Curved with inlet vanes",
|
|
7955
|
-
"category": "FanEIR-FPLR",
|
|
7956
|
-
"form": "Cubic",
|
|
7957
|
-
"dependent_variable": "PwrRatio",
|
|
7958
|
-
"independent_variable_1": "FlowRatio",
|
|
7959
|
-
"independent_variable_2": null,
|
|
7960
|
-
"coeff_1": 0.3038,
|
|
7961
|
-
"coeff_2": -0.7608,
|
|
7962
|
-
"coeff_3": 2.2729,
|
|
7963
|
-
"coeff_4": -0.8169,
|
|
7964
|
-
"coeff_5": null,
|
|
7965
|
-
"coeff_6": null,
|
|
7966
|
-
"coeff_7": null,
|
|
7967
|
-
"coeff_8": null,
|
|
7968
|
-
"coeff_9": null,
|
|
7969
|
-
"coeff_10": null,
|
|
7970
|
-
"minimum_independent_variable_1": 0.0,
|
|
7971
|
-
"maximum_independent_variable_1": 1.0,
|
|
7972
|
-
"minimum_independent_variable_2": null,
|
|
7973
|
-
"maximum_independent_variable_2": null,
|
|
7974
|
-
"minimum_dependent_variable_output": 0.3,
|
|
7975
|
-
"maximum_dependent_variable_output": null,
|
|
7976
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7977
|
-
},
|
|
7978
|
-
{
|
|
7979
|
-
"name": "Multi Zone VAV with VSD and fixed SP setpoint",
|
|
7980
|
-
"category": "FanEIR-FPLR",
|
|
7981
|
-
"form": "Cubic",
|
|
7982
|
-
"dependent_variable": "PwrRatio",
|
|
7983
|
-
"independent_variable_1": "FlowRatio",
|
|
7984
|
-
"independent_variable_2": null,
|
|
7985
|
-
"coeff_1": 0.0013,
|
|
7986
|
-
"coeff_2": 0.147,
|
|
7987
|
-
"coeff_3": 0.9506,
|
|
7988
|
-
"coeff_4": -0.0998,
|
|
7989
|
-
"coeff_5": null,
|
|
7990
|
-
"coeff_6": null,
|
|
7991
|
-
"coeff_7": null,
|
|
7992
|
-
"coeff_8": null,
|
|
7993
|
-
"coeff_9": null,
|
|
7994
|
-
"coeff_10": null,
|
|
7995
|
-
"minimum_independent_variable_1": 0.0,
|
|
7996
|
-
"maximum_independent_variable_1": 1.0,
|
|
7997
|
-
"minimum_independent_variable_2": null,
|
|
7998
|
-
"maximum_independent_variable_2": null,
|
|
7999
|
-
"minimum_dependent_variable_output": 0.2,
|
|
8000
|
-
"maximum_dependent_variable_output": null,
|
|
8001
|
-
"notes": "Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
8002
|
-
},
|
|
8003
|
-
{
|
|
8004
|
-
"name": "Multi Zone VAV with vane-axial with variable pitch blades",
|
|
8005
|
-
"category": "FanEIR-FPLR",
|
|
8006
|
-
"form": "Cubic",
|
|
8007
|
-
"dependent_variable": "PwrRatio",
|
|
8008
|
-
"independent_variable_1": "FlowRatio",
|
|
8009
|
-
"independent_variable_2": null,
|
|
8010
|
-
"coeff_1": 0.1639,
|
|
8011
|
-
"coeff_2": -0.4016,
|
|
8012
|
-
"coeff_3": 1.9909,
|
|
8013
|
-
"coeff_4": -0.7541,
|
|
8014
|
-
"coeff_5": null,
|
|
8015
|
-
"coeff_6": null,
|
|
8016
|
-
"coeff_7": null,
|
|
8017
|
-
"coeff_8": null,
|
|
8018
|
-
"coeff_9": null,
|
|
8019
|
-
"coeff_10": null,
|
|
8020
|
-
"minimum_independent_variable_1": 0.0,
|
|
8021
|
-
"maximum_independent_variable_1": 1.0,
|
|
8022
|
-
"minimum_independent_variable_2": null,
|
|
8023
|
-
"maximum_independent_variable_2": null,
|
|
8024
|
-
"minimum_dependent_variable_output": 0.2,
|
|
8025
|
-
"maximum_dependent_variable_output": null,
|
|
8026
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
8027
|
-
},
|
|
8028
|
-
{
|
|
8029
|
-
"name": "Multi zone VAV with static pressure reset",
|
|
8030
|
-
"category": "FanEIR-FPLR",
|
|
8031
|
-
"form": "Cubic",
|
|
8032
|
-
"dependent_variable": "PwrRatio",
|
|
8033
|
-
"independent_variable_1": "FlowRatio",
|
|
8034
|
-
"independent_variable_2": null,
|
|
8035
|
-
"coeff_1": 0.040759894,
|
|
8036
|
-
"coeff_2": 0.08804497,
|
|
8037
|
-
"coeff_3": -0.07292612,
|
|
8038
|
-
"coeff_4": 0.943739823,
|
|
8039
|
-
"coeff_5": null,
|
|
8040
|
-
"coeff_6": null,
|
|
8041
|
-
"coeff_7": null,
|
|
8042
|
-
"coeff_8": null,
|
|
8043
|
-
"coeff_9": null,
|
|
8044
|
-
"coeff_10": null,
|
|
8045
|
-
"minimum_independent_variable_1": 0.0,
|
|
8046
|
-
"maximum_independent_variable_1": 1.0,
|
|
8047
|
-
"minimum_independent_variable_2": null,
|
|
8048
|
-
"maximum_independent_variable_2": null,
|
|
8049
|
-
"minimum_dependent_variable_output": 0.1,
|
|
8050
|
-
"maximum_dependent_variable_output": null,
|
|
8051
|
-
"notes": "OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
8052
|
-
},
|
|
8053
7878
|
{
|
|
8054
7879
|
"name": "New_Low_Temp_Comp_Cap_Curve",
|
|
8055
7880
|
"category": null,
|
|
@@ -12700,31 +12525,6 @@
|
|
|
12700
12525
|
"maximum_dependent_variable_output": null,
|
|
12701
12526
|
"notes": "From Reference Buildings"
|
|
12702
12527
|
},
|
|
12703
|
-
{
|
|
12704
|
-
"name": "Single zone VAV fan",
|
|
12705
|
-
"category": "FanEIR-FPLR",
|
|
12706
|
-
"form": "Cubic",
|
|
12707
|
-
"dependent_variable": "PwrRatio",
|
|
12708
|
-
"independent_variable_1": "FlowRatio",
|
|
12709
|
-
"independent_variable_2": null,
|
|
12710
|
-
"coeff_1": 0.027827882,
|
|
12711
|
-
"coeff_2": 0.026583195,
|
|
12712
|
-
"coeff_3": -0.0870687,
|
|
12713
|
-
"coeff_4": 1.03091975,
|
|
12714
|
-
"coeff_5": null,
|
|
12715
|
-
"coeff_6": null,
|
|
12716
|
-
"coeff_7": null,
|
|
12717
|
-
"coeff_8": null,
|
|
12718
|
-
"coeff_9": null,
|
|
12719
|
-
"coeff_10": null,
|
|
12720
|
-
"minimum_independent_variable_1": 0.0,
|
|
12721
|
-
"maximum_independent_variable_1": 1.0,
|
|
12722
|
-
"minimum_independent_variable_2": null,
|
|
12723
|
-
"maximum_independent_variable_2": null,
|
|
12724
|
-
"minimum_dependent_variable_output": 0.1,
|
|
12725
|
-
"maximum_dependent_variable_output": null,
|
|
12726
|
-
"notes": "Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
12727
|
-
},
|
|
12728
12528
|
{
|
|
12729
12529
|
"name": "Small-CHW-Bypass-fAirflow",
|
|
12730
12530
|
"category": "CHWCoils",
|
|
@@ -7875,181 +7875,6 @@
|
|
|
7875
7875
|
"maximum_dependent_variable_output": null,
|
|
7876
7876
|
"notes": "From Reference Buildings"
|
|
7877
7877
|
},
|
|
7878
|
-
{
|
|
7879
|
-
"name": "Multi Zone VAV with Airfoil or Backward Incline riding the curve",
|
|
7880
|
-
"category": "FanEIR-FPLR",
|
|
7881
|
-
"form": "Cubic",
|
|
7882
|
-
"dependent_variable": "PwrRatio",
|
|
7883
|
-
"independent_variable_1": "FlowRatio",
|
|
7884
|
-
"independent_variable_2": null,
|
|
7885
|
-
"coeff_1": 0.1631,
|
|
7886
|
-
"coeff_2": 1.5901,
|
|
7887
|
-
"coeff_3": -0.8817,
|
|
7888
|
-
"coeff_4": 0.1281,
|
|
7889
|
-
"coeff_5": null,
|
|
7890
|
-
"coeff_6": null,
|
|
7891
|
-
"coeff_7": null,
|
|
7892
|
-
"coeff_8": null,
|
|
7893
|
-
"coeff_9": null,
|
|
7894
|
-
"coeff_10": null,
|
|
7895
|
-
"minimum_independent_variable_1": 0.0,
|
|
7896
|
-
"maximum_independent_variable_1": 1.0,
|
|
7897
|
-
"minimum_independent_variable_2": null,
|
|
7898
|
-
"maximum_independent_variable_2": null,
|
|
7899
|
-
"minimum_dependent_variable_output": 0.7,
|
|
7900
|
-
"maximum_dependent_variable_output": null,
|
|
7901
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7902
|
-
},
|
|
7903
|
-
{
|
|
7904
|
-
"name": "Multi Zone VAV with Airfoil or Backward Incline with inlet vanes",
|
|
7905
|
-
"category": "FanEIR-FPLR",
|
|
7906
|
-
"form": "Cubic",
|
|
7907
|
-
"dependent_variable": "PwrRatio",
|
|
7908
|
-
"independent_variable_1": "FlowRatio",
|
|
7909
|
-
"independent_variable_2": null,
|
|
7910
|
-
"coeff_1": 0.9977,
|
|
7911
|
-
"coeff_2": -0.659,
|
|
7912
|
-
"coeff_3": 0.9547,
|
|
7913
|
-
"coeff_4": -0.2936,
|
|
7914
|
-
"coeff_5": null,
|
|
7915
|
-
"coeff_6": null,
|
|
7916
|
-
"coeff_7": null,
|
|
7917
|
-
"coeff_8": null,
|
|
7918
|
-
"coeff_9": null,
|
|
7919
|
-
"coeff_10": null,
|
|
7920
|
-
"minimum_independent_variable_1": 0.0,
|
|
7921
|
-
"maximum_independent_variable_1": 1.0,
|
|
7922
|
-
"minimum_independent_variable_2": null,
|
|
7923
|
-
"maximum_independent_variable_2": null,
|
|
7924
|
-
"minimum_dependent_variable_output": 0.5,
|
|
7925
|
-
"maximum_dependent_variable_output": null,
|
|
7926
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7927
|
-
},
|
|
7928
|
-
{
|
|
7929
|
-
"name": "Multi Zone VAV with Forward Curved fans riding the curve",
|
|
7930
|
-
"category": "FanEIR-FPLR",
|
|
7931
|
-
"form": "Cubic",
|
|
7932
|
-
"dependent_variable": "PwrRatio",
|
|
7933
|
-
"independent_variable_1": "FlowRatio",
|
|
7934
|
-
"independent_variable_2": null,
|
|
7935
|
-
"coeff_1": 0.1224,
|
|
7936
|
-
"coeff_2": 0.612,
|
|
7937
|
-
"coeff_3": 0.5983,
|
|
7938
|
-
"coeff_4": -0.3334,
|
|
7939
|
-
"coeff_5": null,
|
|
7940
|
-
"coeff_6": null,
|
|
7941
|
-
"coeff_7": null,
|
|
7942
|
-
"coeff_8": null,
|
|
7943
|
-
"coeff_9": null,
|
|
7944
|
-
"coeff_10": null,
|
|
7945
|
-
"minimum_independent_variable_1": 0.0,
|
|
7946
|
-
"maximum_independent_variable_1": 1.0,
|
|
7947
|
-
"minimum_independent_variable_2": null,
|
|
7948
|
-
"maximum_independent_variable_2": null,
|
|
7949
|
-
"minimum_dependent_variable_output": 0.3,
|
|
7950
|
-
"maximum_dependent_variable_output": null,
|
|
7951
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7952
|
-
},
|
|
7953
|
-
{
|
|
7954
|
-
"name": "Multi Zone VAV with Forward Curved with inlet vanes",
|
|
7955
|
-
"category": "FanEIR-FPLR",
|
|
7956
|
-
"form": "Cubic",
|
|
7957
|
-
"dependent_variable": "PwrRatio",
|
|
7958
|
-
"independent_variable_1": "FlowRatio",
|
|
7959
|
-
"independent_variable_2": null,
|
|
7960
|
-
"coeff_1": 0.3038,
|
|
7961
|
-
"coeff_2": -0.7608,
|
|
7962
|
-
"coeff_3": 2.2729,
|
|
7963
|
-
"coeff_4": -0.8169,
|
|
7964
|
-
"coeff_5": null,
|
|
7965
|
-
"coeff_6": null,
|
|
7966
|
-
"coeff_7": null,
|
|
7967
|
-
"coeff_8": null,
|
|
7968
|
-
"coeff_9": null,
|
|
7969
|
-
"coeff_10": null,
|
|
7970
|
-
"minimum_independent_variable_1": 0.0,
|
|
7971
|
-
"maximum_independent_variable_1": 1.0,
|
|
7972
|
-
"minimum_independent_variable_2": null,
|
|
7973
|
-
"maximum_independent_variable_2": null,
|
|
7974
|
-
"minimum_dependent_variable_output": 0.3,
|
|
7975
|
-
"maximum_dependent_variable_output": null,
|
|
7976
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
7977
|
-
},
|
|
7978
|
-
{
|
|
7979
|
-
"name": "Multi Zone VAV with VSD and fixed SP setpoint",
|
|
7980
|
-
"category": "FanEIR-FPLR",
|
|
7981
|
-
"form": "Cubic",
|
|
7982
|
-
"dependent_variable": "PwrRatio",
|
|
7983
|
-
"independent_variable_1": "FlowRatio",
|
|
7984
|
-
"independent_variable_2": null,
|
|
7985
|
-
"coeff_1": 0.0013,
|
|
7986
|
-
"coeff_2": 0.147,
|
|
7987
|
-
"coeff_3": 0.9506,
|
|
7988
|
-
"coeff_4": -0.0998,
|
|
7989
|
-
"coeff_5": null,
|
|
7990
|
-
"coeff_6": null,
|
|
7991
|
-
"coeff_7": null,
|
|
7992
|
-
"coeff_8": null,
|
|
7993
|
-
"coeff_9": null,
|
|
7994
|
-
"coeff_10": null,
|
|
7995
|
-
"minimum_independent_variable_1": 0.0,
|
|
7996
|
-
"maximum_independent_variable_1": 1.0,
|
|
7997
|
-
"minimum_independent_variable_2": null,
|
|
7998
|
-
"maximum_independent_variable_2": null,
|
|
7999
|
-
"minimum_dependent_variable_output": 0.2,
|
|
8000
|
-
"maximum_dependent_variable_output": null,
|
|
8001
|
-
"notes": "Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
8002
|
-
},
|
|
8003
|
-
{
|
|
8004
|
-
"name": "Multi Zone VAV with vane-axial with variable pitch blades",
|
|
8005
|
-
"category": "FanEIR-FPLR",
|
|
8006
|
-
"form": "Cubic",
|
|
8007
|
-
"dependent_variable": "PwrRatio",
|
|
8008
|
-
"independent_variable_1": "FlowRatio",
|
|
8009
|
-
"independent_variable_2": null,
|
|
8010
|
-
"coeff_1": 0.1639,
|
|
8011
|
-
"coeff_2": -0.4016,
|
|
8012
|
-
"coeff_3": 1.9909,
|
|
8013
|
-
"coeff_4": -0.7541,
|
|
8014
|
-
"coeff_5": null,
|
|
8015
|
-
"coeff_6": null,
|
|
8016
|
-
"coeff_7": null,
|
|
8017
|
-
"coeff_8": null,
|
|
8018
|
-
"coeff_9": null,
|
|
8019
|
-
"coeff_10": null,
|
|
8020
|
-
"minimum_independent_variable_1": 0.0,
|
|
8021
|
-
"maximum_independent_variable_1": 1.0,
|
|
8022
|
-
"minimum_independent_variable_2": null,
|
|
8023
|
-
"maximum_independent_variable_2": null,
|
|
8024
|
-
"minimum_dependent_variable_output": 0.2,
|
|
8025
|
-
"maximum_dependent_variable_output": null,
|
|
8026
|
-
"notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
8027
|
-
},
|
|
8028
|
-
{
|
|
8029
|
-
"name": "Multi zone VAV with static pressure reset",
|
|
8030
|
-
"category": "FanEIR-FPLR",
|
|
8031
|
-
"form": "Cubic",
|
|
8032
|
-
"dependent_variable": "PwrRatio",
|
|
8033
|
-
"independent_variable_1": "FlowRatio",
|
|
8034
|
-
"independent_variable_2": null,
|
|
8035
|
-
"coeff_1": 0.040759894,
|
|
8036
|
-
"coeff_2": 0.08804497,
|
|
8037
|
-
"coeff_3": -0.07292612,
|
|
8038
|
-
"coeff_4": 0.943739823,
|
|
8039
|
-
"coeff_5": null,
|
|
8040
|
-
"coeff_6": null,
|
|
8041
|
-
"coeff_7": null,
|
|
8042
|
-
"coeff_8": null,
|
|
8043
|
-
"coeff_9": null,
|
|
8044
|
-
"coeff_10": null,
|
|
8045
|
-
"minimum_independent_variable_1": 0.0,
|
|
8046
|
-
"maximum_independent_variable_1": 1.0,
|
|
8047
|
-
"minimum_independent_variable_2": null,
|
|
8048
|
-
"maximum_independent_variable_2": null,
|
|
8049
|
-
"minimum_dependent_variable_output": 0.1,
|
|
8050
|
-
"maximum_dependent_variable_output": null,
|
|
8051
|
-
"notes": "OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
8052
|
-
},
|
|
8053
7878
|
{
|
|
8054
7879
|
"name": "New_Low_Temp_Comp_Cap_Curve",
|
|
8055
7880
|
"category": null,
|
|
@@ -12700,31 +12525,6 @@
|
|
|
12700
12525
|
"maximum_dependent_variable_output": null,
|
|
12701
12526
|
"notes": "From Reference Buildings"
|
|
12702
12527
|
},
|
|
12703
|
-
{
|
|
12704
|
-
"name": "Single zone VAV fan",
|
|
12705
|
-
"category": "FanEIR-FPLR",
|
|
12706
|
-
"form": "Cubic",
|
|
12707
|
-
"dependent_variable": "PwrRatio",
|
|
12708
|
-
"independent_variable_1": "FlowRatio",
|
|
12709
|
-
"independent_variable_2": null,
|
|
12710
|
-
"coeff_1": 0.027827882,
|
|
12711
|
-
"coeff_2": 0.026583195,
|
|
12712
|
-
"coeff_3": -0.0870687,
|
|
12713
|
-
"coeff_4": 1.03091975,
|
|
12714
|
-
"coeff_5": null,
|
|
12715
|
-
"coeff_6": null,
|
|
12716
|
-
"coeff_7": null,
|
|
12717
|
-
"coeff_8": null,
|
|
12718
|
-
"coeff_9": null,
|
|
12719
|
-
"coeff_10": null,
|
|
12720
|
-
"minimum_independent_variable_1": 0.0,
|
|
12721
|
-
"maximum_independent_variable_1": 1.0,
|
|
12722
|
-
"minimum_independent_variable_2": null,
|
|
12723
|
-
"maximum_independent_variable_2": null,
|
|
12724
|
-
"minimum_dependent_variable_output": 0.1,
|
|
12725
|
-
"maximum_dependent_variable_output": null,
|
|
12726
|
-
"notes": "Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
|
|
12727
|
-
},
|
|
12728
12528
|
{
|
|
12729
12529
|
"name": "Small-CHW-Bypass-fAirflow",
|
|
12730
12530
|
"category": "CHWCoils",
|
|
@@ -6,8 +6,13 @@ class BTAPPRE1980 < NECB2011
|
|
|
6
6
|
|
|
7
7
|
def initialize
|
|
8
8
|
super()
|
|
9
|
+
@template = self.class.name
|
|
9
10
|
@standards_data = load_standards_database_new
|
|
10
11
|
corrupt_standards_database
|
|
12
|
+
@tbd = nil
|
|
13
|
+
@activity = nil
|
|
14
|
+
@structure = nil
|
|
15
|
+
@osut = {gra0: 0, graX: 0, status: 0, logs: []} # "gra": "gross roof area"
|
|
11
16
|
end
|
|
12
17
|
|
|
13
18
|
def load_standards_database_new
|
|
@@ -45,21 +50,25 @@ class BTAPPRE1980 < NECB2011
|
|
|
45
50
|
end
|
|
46
51
|
|
|
47
52
|
# Thermal zones need to be set to determine conditioned spaces when applying fdwr and srr limits.
|
|
48
|
-
#
|
|
49
|
-
#
|
|
50
|
-
#
|
|
51
|
-
#
|
|
52
|
-
#
|
|
53
|
-
#
|
|
54
|
-
#
|
|
55
|
-
#
|
|
56
|
-
|
|
53
|
+
#
|
|
54
|
+
# fdwr_set/srr_set settings:
|
|
55
|
+
# 0-1: Remove all windows/skylights and add windows/skylights to match this fdwr/srr
|
|
56
|
+
# -1: Remove all windows/skylights and add windows/skylights to match max fdwr/srr from NECB
|
|
57
|
+
# -2: Do not apply any fdwr/srr changes, leave windows/skylights alone (also works for fdwr/srr > 1)
|
|
58
|
+
# -3: Use old method which reduces existing window/skylight size (if necessary) to meet maximum NECB fdwr/srr limit
|
|
59
|
+
# <-3.1: Remove all the windows/skylights
|
|
60
|
+
# > 1: Do nothing
|
|
61
|
+
#
|
|
62
|
+
# By default, :srr_opt is an empty string (" "). If set to "osut", SRR is
|
|
63
|
+
# instead met using OSut's 'addSkylights' (:srr_set numeric values may apply).
|
|
64
|
+
def apply_fdwr_srr_daylighting(model:, fdwr_set: -1.0, srr_set: -1.0, necb_hdd: true, srr_opt: '')
|
|
57
65
|
fdwr_set = -2.0 if (fdwr_set == 'NECB_default') || fdwr_set.nil? || (fdwr_set.to_f.round(0) == -1.0)
|
|
58
66
|
srr_set = -2.0 if (srr_set == 'NECB_default') || srr_set.nil? || (srr_set.to_f.round(0) == -1.0)
|
|
59
67
|
fdwr_set = fdwr_set.to_f
|
|
60
68
|
srr_set = srr_set.to_f
|
|
61
69
|
apply_standard_window_to_wall_ratio(model: model, fdwr_set: fdwr_set, necb_hdd: true)
|
|
62
|
-
apply_standard_skylight_to_roof_ratio(model: model, srr_set: srr_set)
|
|
70
|
+
# apply_standard_skylight_to_roof_ratio(model: model, srr_set: srr_set)
|
|
71
|
+
apply_standard_skylight_to_roof_ratio(model: model, srr_set: srr_set, srr_opt: srr_opt)
|
|
63
72
|
# model_add_daylighting_controls(model) # to be removed after refactor.
|
|
64
73
|
end
|
|
65
74
|
|
|
@@ -24,27 +24,28 @@ class BTAPPRE1980
|
|
|
24
24
|
|
|
25
25
|
# Reduces the SRR to the values specified by the PRM. SRR reduction
|
|
26
26
|
# will be done by shrinking vertices toward the centroid.
|
|
27
|
-
|
|
28
|
-
def apply_standard_skylight_to_roof_ratio(model:, srr_set: -1.0)
|
|
27
|
+
def apply_standard_skylight_to_roof_ratio(model:, srr_set: -1.0, srr_opt: '')
|
|
29
28
|
# If srr_set is between 1.0 and 1.2 set it to the maximum allowed by the NECB. If srr_set is between 0.0 and 1.0
|
|
30
29
|
# apply whatever was passed. If srr_set >= 1.2 then set the existing srr of the building to be the necb maximum
|
|
31
30
|
# only if the the srr exceeds this maximum (otherwise leave it to be whatever was modeled).
|
|
32
31
|
|
|
33
32
|
# srr_set settings:
|
|
34
|
-
#
|
|
35
|
-
#
|
|
36
|
-
#
|
|
37
|
-
#
|
|
38
|
-
# <-3.1: Remove all
|
|
39
|
-
#
|
|
40
|
-
|
|
33
|
+
# 0-1: Remove all skylights and add skylights to match this srr
|
|
34
|
+
# -1: Remove all skylights and add skylights to match max srr from NECB
|
|
35
|
+
# -2: Do not apply any srr changes, leave skylights alone (also works for srr > 1)
|
|
36
|
+
# -3: Use old method which reduces existing skylight size (if necessary) to meet maximum NECB skylight limit
|
|
37
|
+
# <-3.1: Remove all skylights
|
|
38
|
+
# > 1: Do nothing
|
|
39
|
+
#
|
|
40
|
+
# By default, :srr_opt is an empty string (" "). If set to "osut", SRR is
|
|
41
|
+
# instead met using OSut's addSkylights (:srr_set numeric values may apply).
|
|
41
42
|
return if srr_set.to_f > 1.0
|
|
42
|
-
return apply_max_srr_nrcan(model: model, srr_lim: srr_set.to_f) if srr_set.to_f >= 0.0 && srr_set <= 1.0
|
|
43
|
+
return apply_max_srr_nrcan(model: model, srr_lim: srr_set.to_f, srr_opt: srr_opt) if srr_set.to_f >= 0.0 && srr_set.to_f <= 1.0
|
|
43
44
|
|
|
44
45
|
# No skylights set for BTAPPRE1980 buildings.
|
|
45
46
|
return if srr_set.to_f >= -1.1 && srr_set <= -0.9
|
|
46
47
|
return if srr_set.to_f >= -2.1 && srr_set <= -1.9
|
|
47
|
-
return apply_max_srr_nrcan(model: model, srr_lim: srr_set.to_f) if srr_set < -3.1
|
|
48
|
+
return apply_max_srr_nrcan(model: model, srr_lim: srr_set.to_f, srr_opt: srr_opt) if srr_set.to_f < -3.1
|
|
48
49
|
|
|
49
50
|
# Continue with the rest of this method, use old method which reduces existing skylight size (if necessary) to
|
|
50
51
|
# meet maximum srr limit
|
|
@@ -23,13 +23,13 @@ class BTAPPRE1980
|
|
|
23
23
|
compressor_type = search_criteria['compressor_type']
|
|
24
24
|
|
|
25
25
|
# Get the chiller capacity
|
|
26
|
-
capacity_w =
|
|
26
|
+
capacity_w = OpenstudioStandards::HVAC.chiller_electric_get_capacity(chiller_electric_eir)
|
|
27
27
|
|
|
28
28
|
# All chillers must be modulating down to 25% of their capacity
|
|
29
29
|
chiller_electric_eir.setChillerFlowMode('LeavingSetpointModulated')
|
|
30
30
|
chiller_electric_eir.setMinimumPartLoadRatio(0.25)
|
|
31
31
|
chiller_electric_eir.setMinimumUnloadingRatio(0.25)
|
|
32
|
-
|
|
32
|
+
|
|
33
33
|
chiller_capacity = capacity_w
|
|
34
34
|
if (capacity_w / 1000.0) <= 700.0
|
|
35
35
|
# As per MNECB if chiller capacity <= 700 kW the compressor should be reciprocating so change the type here in
|
|
@@ -106,11 +106,11 @@ class BTAPPRE1980
|
|
|
106
106
|
cop = nil
|
|
107
107
|
if chlr_props['cop']
|
|
108
108
|
cop = chlr_props['cop']
|
|
109
|
-
kw_per_ton = cop_to_kw_per_ton(cop)
|
|
109
|
+
kw_per_ton = OpenstudioStandards::HVAC.cop_to_kw_per_ton(cop)
|
|
110
110
|
chiller_electric_eir.setReferenceCOP(cop)
|
|
111
111
|
elsif !chlr_props['cop'] && chlr_props['minimum_full_load_efficiency']
|
|
112
112
|
kw_per_ton = chlr_props['minimum_full_load_efficiency']
|
|
113
|
-
cop = kw_per_ton_to_cop(kw_per_ton)
|
|
113
|
+
cop = OpenstudioStandards::HVAC.kw_per_ton_to_cop(kw_per_ton)
|
|
114
114
|
chiller_electric_eir.setReferenceCOP(cop)
|
|
115
115
|
else
|
|
116
116
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.ChillerElectricEIR', "For #{chiller_electric_eir.name}, cannot find minimum full load efficiency, will not be set.")
|
|
@@ -60,7 +60,7 @@ class ECMS < NECB2011
|
|
|
60
60
|
|
|
61
61
|
# when the ecm is associated with adding a new HVAC system, then remove existing system components and loops
|
|
62
62
|
ecm_std.remove_all_zone_eqpt(systems)
|
|
63
|
-
|
|
63
|
+
OpenstudioStandards::HVAC.remove_air_loops(model)
|
|
64
64
|
ecm_std.remove_hw_loops(model)
|
|
65
65
|
ecm_std.remove_chw_loops(model)
|
|
66
66
|
ecm_std.remove_cw_loops(model)
|