openstudio-standards 0.8.4 → 0.8.5.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (289) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.osm +30 -30
  3. data/data/geometry/ASHRAECourthouse.osm +22 -22
  4. data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
  5. data/data/geometry/DEER_Asm.osm +1 -1
  6. data/data/geometry/DEER_ECC.osm +1 -1
  7. data/data/geometry/DEER_EPr.osm +1 -1
  8. data/data/geometry/DEER_ERC.osm +1 -1
  9. data/data/geometry/DEER_ESe.osm +1 -1
  10. data/data/geometry/DEER_EUn.osm +1 -1
  11. data/data/geometry/DEER_Hsp.osm +1 -1
  12. data/data/geometry/DEER_Htl.osm +1 -1
  13. data/data/geometry/DEER_MBT.osm +1 -1
  14. data/data/geometry/DEER_MFm.osm +1 -1
  15. data/data/geometry/DEER_Nrs.osm +1 -1
  16. data/data/geometry/DEER_OfL.osm +1 -1
  17. data/data/geometry/DEER_OfS.osm +1 -1
  18. data/data/geometry/DEER_RFF.osm +1 -1
  19. data/data/geometry/DEER_RSD.osm +1 -1
  20. data/data/geometry/DEER_Rt3.osm +1 -1
  21. data/data/geometry/DEER_RtS.osm +1 -1
  22. data/data/standards/export_OpenStudio_libraries.rb +2 -3
  23. data/data/standards/test_performance_expected_dd_results.csv +42 -42
  24. data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
  25. data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
  26. data/lib/openstudio-standards/btap/activity.rb +480 -0
  27. data/lib/openstudio-standards/btap/attributes.rb +166 -0
  28. data/lib/openstudio-standards/btap/bridging.rb +561 -1402
  29. data/lib/openstudio-standards/btap/btap.rb +4 -2
  30. data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
  31. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
  32. data/lib/openstudio-standards/btap/{costing/common_paths.rb → common_paths.rb} +14 -11
  33. data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
  34. data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
  35. data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
  36. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
  37. data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
  38. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting.csv +59 -59
  39. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_hvac.csv +1019 -1032
  40. data/lib/openstudio-standards/btap/costing/btap_costing.rb +3 -7
  41. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +1 -5
  42. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +5 -4
  43. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +1 -1
  44. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +112 -181
  45. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +4 -4
  46. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +2 -1
  47. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +3 -3
  48. data/lib/openstudio-standards/btap/costing/test_list.txt +15 -17
  49. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +10 -9
  50. data/lib/openstudio-standards/btap/geometry.rb +86 -6
  51. data/lib/openstudio-standards/btap/structure.rb +657 -0
  52. data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
  53. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
  54. data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
  55. data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
  56. data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
  57. data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
  58. data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
  59. data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
  60. data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
  61. data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
  62. data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
  63. data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
  64. data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
  65. data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
  66. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
  67. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
  68. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
  69. data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
  70. data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
  71. data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
  72. data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
  73. data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
  74. data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
  75. data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
  76. data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
  77. data/lib/openstudio-standards/hvac/components/component.rb +39 -0
  78. data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
  79. data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
  80. data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
  81. data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
  82. data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
  83. data/lib/openstudio-standards/hvac/conversions.rb +222 -0
  84. data/lib/openstudio-standards/hvac/curves.rb +192 -0
  85. data/lib/openstudio-standards/hvac/helpers.rb +357 -0
  86. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
  87. data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
  88. data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
  89. data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
  90. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
  91. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
  92. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
  93. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  99. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
  100. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  101. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  102. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
  103. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
  111. data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
  112. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
  113. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
  114. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
  115. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
  116. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
  117. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
  118. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
  119. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
  120. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
  121. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
  122. data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
  123. data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
  124. data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
  125. data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
  126. data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
  127. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
  128. data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
  129. data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
  130. data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
  131. data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
  132. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
  133. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
  134. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
  135. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
  136. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
  137. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
  138. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
  139. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
  140. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
  141. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
  142. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
  143. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
  144. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
  145. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
  146. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
  147. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
  148. data/lib/openstudio-standards/standards/Standards.Model.rb +6 -11
  149. data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
  150. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
  151. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
  152. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
  153. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
  154. data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
  155. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
  156. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
  157. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
  158. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
  159. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
  160. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
  161. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
  162. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  163. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
  164. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
  165. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
  166. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  167. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
  168. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
  169. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
  170. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
  171. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  172. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
  182. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
  183. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
  184. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
  185. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
  186. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
  187. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
  188. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  189. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  191. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
  192. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
  193. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
  194. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
  195. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
  196. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
  197. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
  198. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
  199. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
  200. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
  202. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
  203. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
  204. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
  205. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +1 -0
  206. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
  207. data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
  208. data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
  209. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +19 -10
  210. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
  211. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
  212. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
  213. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +69 -92
  214. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +2 -1
  215. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
  216. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
  217. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
  218. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +32 -0
  219. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +18 -0
  220. data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
  221. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +5 -5
  222. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +2 -0
  223. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +30 -141
  224. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +233 -112
  225. data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
  226. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -2
  227. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
  228. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
  229. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
  230. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
  231. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +16 -4
  232. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +65 -42
  233. data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
  234. data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
  235. data/lib/openstudio-standards/version.rb +1 -1
  236. data/lib/openstudio-standards/weather/stat_file.rb +2 -2
  237. data/lib/openstudio-standards.rb +55 -38
  238. metadata +106 -66
  239. data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +0 -61
  240. data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +0 -1904
  241. data/lib/openstudio-standards/hvac/components/create.rb +0 -169
  242. data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
  243. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
  244. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
  245. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
  246. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
  247. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
  248. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
  249. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
  250. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
  251. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
  252. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
  253. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
  254. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
  255. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
  256. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
  257. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
  258. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
  259. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
  260. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
  261. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
  262. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
  263. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
  264. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
  265. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
  266. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
  267. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
  268. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
  269. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
  270. data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
  271. data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
  272. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/ConstructionProperties.csv +0 -0
  273. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/Constructions.csv +0 -0
  274. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/construction_sets.csv +0 -0
  275. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/constructions_opaque.csv +0 -0
  276. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/costs_local_factors.csv +0 -0
  277. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/hvac_vent_ahu.csv +0 -0
  278. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting_sets.csv +0 -0
  279. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/locations.csv +0 -0
  280. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_glazing.csv +0 -0
  281. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_lighting.csv +0 -0
  282. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_opaque.csv +0 -0
  283. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
  284. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
  285. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
  286. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
  287. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
  288. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
  289. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
@@ -8,7 +8,7 @@ class ASHRAE9012010 < ASHRAE901
8
8
  # @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
9
9
  # @return [Boolean] returns true if successful, false if not
10
10
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
11
- min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
11
+ min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
12
12
  when 'Electricity', 'NaturalGas'
13
13
  0.3
14
14
  else # 'HotWater', other
@@ -8,7 +8,7 @@ class ASHRAE9012013 < ASHRAE901
8
8
  # @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
9
9
  # @return [Boolean] returns true if successful, false if not
10
10
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
11
- min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
11
+ min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
12
12
  when 'Electricity', 'NaturalGas'
13
13
  0.3
14
14
  else # 'HotWater', other
@@ -8,7 +8,7 @@ class ASHRAE9012016 < ASHRAE901
8
8
  # @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
9
9
  # @return [Boolean] returns true if successful, false if not
10
10
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
11
- min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
11
+ min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
12
12
  when 'Electricity', 'NaturalGas'
13
13
  0.3
14
14
  else # 'HotWater', other
@@ -300,7 +300,7 @@ class ASHRAE9012016 < ASHRAE901
300
300
  key_name = space.name.to_s
301
301
  end
302
302
  light_sensor.setKeyName(key_name)
303
- light_sensor_name_ems = "#{ems_friendly_name(key_name)}_LSr"
303
+ light_sensor_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_LSr"
304
304
  light_sensor.setName(light_sensor_name_ems)
305
305
 
306
306
  # get the space floor area for calculations
@@ -328,7 +328,7 @@ class ASHRAE9012016 < ASHRAE901
328
328
  else
329
329
  light_x_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(light_x, 'Lights', 'Electricity Rate')
330
330
  end
331
- light_x_actuator_name_ems = "#{ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
331
+ light_x_actuator_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
332
332
  light_x_actuator.setName(light_x_actuator_name_ems)
333
333
  add_lights_prog_null += "\n SET #{light_x_actuator_name_ems} = NULL,"
334
334
  if light_x == big_light
@@ -339,7 +339,7 @@ class ASHRAE9012016 < ASHRAE901
339
339
  end
340
340
 
341
341
  light_ems_prog = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
342
- light_ems_prog.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program")
342
+ light_ems_prog.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program")
343
343
  light_ems_prog_body = <<-EMS
344
344
  SET #{light_sensor_name_ems}_IP=0.093*#{light_sensor_name_ems}/#{space_floor_area},
345
345
  IF (#{business_sensor_name} <= 0) && (#{light_sensor_name_ems}_IP >= 0.02),#{add_lights_prog_0}
@@ -349,7 +349,7 @@ class ASHRAE9012016 < ASHRAE901
349
349
  light_ems_prog.setBody(light_ems_prog_body)
350
350
 
351
351
  light_ems_prog_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
352
- light_ems_prog_manager.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
352
+ light_ems_prog_manager.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
353
353
  light_ems_prog_manager.setCallingPoint('AfterPredictorAfterHVACManagers')
354
354
  light_ems_prog_manager.addProgram(light_ems_prog)
355
355
  end
@@ -8,7 +8,7 @@ class ASHRAE9012019 < ASHRAE901
8
8
  # @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
9
9
  # @return [Boolean] returns true if successful, false if not
10
10
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
11
- min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
11
+ min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
12
12
  when 'Electricity', 'NaturalGas'
13
13
  0.3
14
14
  else # 'HotWater', other
@@ -300,7 +300,7 @@ class ASHRAE9012019 < ASHRAE901
300
300
  key_name = space.name.to_s
301
301
  end
302
302
  light_sensor.setKeyName(key_name)
303
- light_sensor_name_ems = "#{ems_friendly_name(key_name)}_LSr"
303
+ light_sensor_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_LSr"
304
304
  light_sensor.setName(light_sensor_name_ems)
305
305
 
306
306
  # get the space floor area for calculations
@@ -328,7 +328,7 @@ class ASHRAE9012019 < ASHRAE901
328
328
  else
329
329
  light_x_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(light_x, 'Lights', 'Electricity Rate')
330
330
  end
331
- light_x_actuator_name_ems = "#{ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
331
+ light_x_actuator_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
332
332
  light_x_actuator.setName(light_x_actuator_name_ems)
333
333
  add_lights_prog_null += "\n SET #{light_x_actuator_name_ems} = NULL,"
334
334
  if light_x == big_light
@@ -339,7 +339,7 @@ class ASHRAE9012019 < ASHRAE901
339
339
  end
340
340
 
341
341
  light_ems_prog = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
342
- light_ems_prog.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program")
342
+ light_ems_prog.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program")
343
343
  light_ems_prog_body = <<-EMS
344
344
  SET #{light_sensor_name_ems}_IP=0.093*#{light_sensor_name_ems}/#{space_floor_area},
345
345
  IF (#{business_sensor_name} <= 0) && (#{light_sensor_name_ems}_IP >= 0.02),#{add_lights_prog_0}
@@ -349,7 +349,7 @@ class ASHRAE9012019 < ASHRAE901
349
349
  light_ems_prog.setBody(light_ems_prog_body)
350
350
 
351
351
  light_ems_prog_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
352
- light_ems_prog_manager.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
352
+ light_ems_prog_manager.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
353
353
  light_ems_prog_manager.setCallingPoint('AfterPredictorAfterHVACManagers')
354
354
  light_ems_prog_manager.addProgram(light_ems_prog)
355
355
  end
@@ -8,7 +8,7 @@ class NRELZNEReady2017 < ASHRAE901
8
8
  # @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
9
9
  # @return [Boolean] returns true if successful, false if not
10
10
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
11
- min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
11
+ min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
12
12
  when 'HotWater'
13
13
  0.2
14
14
  when 'Electricity', 'NaturalGas'
@@ -8,7 +8,7 @@ class ZEAEDGMultifamily < ASHRAE901
8
8
  # @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
9
9
  # @return [Boolean] returns true if successful, false if not
10
10
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
11
- min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
11
+ min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
12
12
  when 'HotWater'
13
13
  0.2
14
14
  when 'Electricity', 'NaturalGas'
@@ -37,13 +37,12 @@ module HighriseApartment
37
37
  'Electric Equipment Electricity Energy'
38
38
  end
39
39
 
40
- model_add_transformer(model,
41
- wired_lighting_frac: 0.0015,
42
- transformer_size: 75000,
43
- transformer_efficiency: transformer_efficiency,
44
- excluded_interiorequip_key: 'T Corridor_Elevators_Equip',
45
- excluded_interiorequip_meter: excluded_interiorequip_variable)
46
-
40
+ OpenstudioStandards::Equipment.create_transformer(model,
41
+ wired_lighting_frac: 0.0015,
42
+ transformer_size: 75000,
43
+ transformer_efficiency: transformer_efficiency,
44
+ excluded_interiorequip_key: 'T Corridor_Elevators_Equip',
45
+ excluded_interiorequip_meter: excluded_interiorequip_variable)
47
46
  return true
48
47
  end
49
48
 
@@ -25,10 +25,10 @@ module Hospital
25
25
  end
26
26
 
27
27
  unless transformer_efficiency.nil?
28
- model_add_transformer(model,
29
- wired_lighting_frac: 0.022,
30
- transformer_size: 500000,
31
- transformer_efficiency: transformer_efficiency)
28
+ OpenstudioStandards::Equipment.create_transformer(model,
29
+ wired_lighting_frac: 0.022,
30
+ transformer_size: 500000,
31
+ transformer_efficiency: transformer_efficiency)
32
32
  end
33
33
 
34
34
  # add extra equipment for kitchen
@@ -85,10 +85,10 @@ module Hospital
85
85
 
86
86
  # replace main supply air fan
87
87
  air_loop.supplyFan.get.remove
88
- fan = create_fan_by_name(model,
89
- 'Hospital_CAV_Sytem_Fan',
90
- fan_name: "#{air_loop.name} Fan",
91
- end_use_subcategory: 'CAV System Fans')
88
+ fan = OpenstudioStandards::HVAC.create_typical_fan(model,
89
+ 'Hospital_CAV_Sytem_Fan',
90
+ fan_name: "#{air_loop.name} Fan",
91
+ end_use_subcategory: 'CAV System Fans')
92
92
  fan.setAvailabilitySchedule(model.alwaysOnDiscreteSchedule)
93
93
  fan.addToNode(air_loop.supplyOutletNode)
94
94
 
@@ -276,13 +276,13 @@ module Hospital
276
276
  humidity_spm = OpenStudio::Model::SetpointManagerSingleZoneHumidityMinimum.new(model)
277
277
  case template
278
278
  when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
279
- create_coil_heating_electric(model,
280
- air_loop_node: supply_outlet_node,
281
- name: "#{space_name} Electric Htg Coil")
282
- create_coil_heating_water(model,
283
- hot_water_loop,
284
- air_loop_node: supply_outlet_node,
285
- name: "#{space_name} Water Htg Coil")
279
+ OpenstudioStandards::HVAC.create_coil_heating_electric(model,
280
+ air_loop_node: supply_outlet_node,
281
+ name: "#{space_name} Electric Htg Coil")
282
+ OpenstudioStandards::HVAC.create_coil_heating_water(model,
283
+ hot_water_loop,
284
+ air_loop_node: supply_outlet_node,
285
+ name: "#{space_name} Water Htg Coil")
286
286
  end
287
287
  # humidity_spm.addToNode(supply_outlet_node)
288
288
  humidity_spm.addToNode(humidifier.outletModelObject.get.to_Node.get)
@@ -25,10 +25,10 @@ module LargeHotel
25
25
  end
26
26
  return true if transformer_efficiency.nil?
27
27
 
28
- model_add_transformer(model,
29
- wired_lighting_frac: 0.0352,
30
- transformer_size: 150000,
31
- transformer_efficiency: transformer_efficiency)
28
+ OpenstudioStandards::Equipment.create_transformer(model,
29
+ wired_lighting_frac: 0.0352,
30
+ transformer_size: 150000,
31
+ transformer_efficiency: transformer_efficiency)
32
32
 
33
33
  # add extra equipment for kitchen
34
34
  add_extra_equip_kitchen(model)
@@ -32,11 +32,11 @@ module LargeOffice
32
32
  end
33
33
  end
34
34
 
35
- model_add_transformer(model,
36
- wired_lighting_frac: 0.0281,
37
- transformer_size: 500000,
38
- transformer_efficiency: transformer_efficiency,
39
- excluded_interiorequip_meter: 'DataCenterPlugLoads:InteriorEquipment:Electricity')
35
+ OpenstudioStandards::Equipment.create_transformer(model,
36
+ wired_lighting_frac: 0.0281,
37
+ transformer_size: 500000,
38
+ transformer_efficiency: transformer_efficiency,
39
+ excluded_interiorequip_meter: 'DataCenterPlugLoads:InteriorEquipment:Electricity')
40
40
 
41
41
  system_to_space_map = define_hvac_system_map(building_type, climate_zone)
42
42
 
@@ -32,12 +32,12 @@ module MediumOffice
32
32
  'Electric Equipment Electricity Energy'
33
33
  end
34
34
 
35
- model_add_transformer(model,
36
- wired_lighting_frac: 0.0281,
37
- transformer_size: 45000,
38
- transformer_efficiency: transformer_efficiency,
39
- excluded_interiorequip_key: '2 Elevator Lift Motors',
40
- excluded_interiorequip_meter: excluded_interiorequip_variable)
35
+ OpenstudioStandards::Equipment.create_transformer(model,
36
+ wired_lighting_frac: 0.0281,
37
+ transformer_size: 45000,
38
+ transformer_efficiency: transformer_efficiency,
39
+ excluded_interiorequip_key: '2 Elevator Lift Motors',
40
+ excluded_interiorequip_meter: excluded_interiorequip_variable)
41
41
 
42
42
  model.getSpaces.sort.each do |space|
43
43
  if space.name.get.to_s == 'Core_bottom'
@@ -273,13 +273,13 @@ module Outpatient
273
273
  humidity_spm = OpenStudio::Model::SetpointManagerSingleZoneHumidityMinimum.new(model)
274
274
  case template
275
275
  when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
276
- create_coil_heating_electric(model,
277
- air_loop_node: supply_outlet_node,
278
- name: 'AHU1 extra Electric Htg Coil')
279
- create_coil_heating_water(model,
280
- hot_water_loop,
281
- air_loop_node: supply_outlet_node,
282
- name: 'AHU1 extra Water Htg Coil')
276
+ OpenstudioStandards::HVAC.create_coil_heating_electric(model,
277
+ air_loop_node: supply_outlet_node,
278
+ name: 'AHU1 extra Electric Htg Coil')
279
+ OpenstudioStandards::HVAC.create_coil_heating_water(model,
280
+ hot_water_loop,
281
+ air_loop_node: supply_outlet_node,
282
+ name: 'AHU1 extra Water Htg Coil')
283
283
  end
284
284
  # humidity_spm.addToNode(supply_outlet_node)
285
285
  humidity_spm.addToNode(humidifier.outletModelObject.get.to_Node.get)
@@ -25,10 +25,10 @@ module PrimarySchool
25
25
  end
26
26
  return true if transformer_efficiency.nil?
27
27
 
28
- model_add_transformer(model,
29
- wired_lighting_frac: 0.0119,
30
- transformer_size: 112500,
31
- transformer_efficiency: transformer_efficiency)
28
+ OpenstudioStandards::Equipment.create_transformer(model,
29
+ wired_lighting_frac: 0.0119,
30
+ transformer_size: 112500,
31
+ transformer_efficiency: transformer_efficiency)
32
32
 
33
33
  # add extra equipment for kitchen
34
34
  add_extra_equip_kitchen(model)
@@ -32,12 +32,12 @@ module SecondarySchool
32
32
  'Electric Equipment Electricity Energy'
33
33
  end
34
34
 
35
- model_add_transformer(model,
36
- wired_lighting_frac: 0.0194,
37
- transformer_size: 225000,
38
- transformer_efficiency: transformer_efficiency,
39
- excluded_interiorequip_key: '2 Elevator Lift Motors',
40
- excluded_interiorequip_meter: excluded_interiorequip_variable)
35
+ OpenstudioStandards::Equipment.create_transformer(model,
36
+ wired_lighting_frac: 0.0194,
37
+ transformer_size: 225000,
38
+ transformer_efficiency: transformer_efficiency,
39
+ excluded_interiorequip_key: '2 Elevator Lift Motors',
40
+ excluded_interiorequip_meter: excluded_interiorequip_variable)
41
41
 
42
42
  # add extra equipment for kitchen
43
43
  add_extra_equip_kitchen(model)
@@ -68,7 +68,11 @@ module SmallOfficeDetailed
68
68
  # add extra infiltration for attic in m3/s (there is no attic in 'DOE Ref Pre-1980')
69
69
  return false if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980'
70
70
 
71
- entry_space = model.getSpaceByName('Attic').get
71
+ if model.getSpaceByName('Attic').is_initialized
72
+ entry_space = model.getSpaceByName('Attic').get
73
+ elsif model.getSpaceByName('Attic 1').is_initialized
74
+ entry_space = model.getSpaceByName('Attic 1').get
75
+ end
72
76
  infiltration_attic = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
73
77
  infiltration_attic.setName('attic Infiltration')
74
78
  infiltration_per_zone_attic = 0.2001