openstudio-standards 0.8.4 → 0.8.5.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/geometry/ASHRAECollege.osm +30 -30
- data/data/geometry/ASHRAECourthouse.osm +22 -22
- data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
- data/data/geometry/DEER_Asm.osm +1 -1
- data/data/geometry/DEER_ECC.osm +1 -1
- data/data/geometry/DEER_EPr.osm +1 -1
- data/data/geometry/DEER_ERC.osm +1 -1
- data/data/geometry/DEER_ESe.osm +1 -1
- data/data/geometry/DEER_EUn.osm +1 -1
- data/data/geometry/DEER_Hsp.osm +1 -1
- data/data/geometry/DEER_Htl.osm +1 -1
- data/data/geometry/DEER_MBT.osm +1 -1
- data/data/geometry/DEER_MFm.osm +1 -1
- data/data/geometry/DEER_Nrs.osm +1 -1
- data/data/geometry/DEER_OfL.osm +1 -1
- data/data/geometry/DEER_OfS.osm +1 -1
- data/data/geometry/DEER_RFF.osm +1 -1
- data/data/geometry/DEER_RSD.osm +1 -1
- data/data/geometry/DEER_Rt3.osm +1 -1
- data/data/geometry/DEER_RtS.osm +1 -1
- data/data/standards/export_OpenStudio_libraries.rb +2 -3
- data/data/standards/test_performance_expected_dd_results.csv +42 -42
- data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
- data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
- data/lib/openstudio-standards/btap/activity.rb +480 -0
- data/lib/openstudio-standards/btap/attributes.rb +166 -0
- data/lib/openstudio-standards/btap/bridging.rb +561 -1402
- data/lib/openstudio-standards/btap/btap.rb +4 -2
- data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
- data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
- data/lib/openstudio-standards/btap/{costing/common_paths.rb → common_paths.rb} +14 -11
- data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
- data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
- data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting.csv +59 -59
- data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_hvac.csv +1019 -1032
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +3 -7
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +1 -5
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +5 -4
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +1 -1
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +112 -181
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +4 -4
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +2 -1
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +3 -3
- data/lib/openstudio-standards/btap/costing/test_list.txt +15 -17
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +10 -9
- data/lib/openstudio-standards/btap/geometry.rb +86 -6
- data/lib/openstudio-standards/btap/structure.rb +657 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
- data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
- data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
- data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
- data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
- data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
- data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
- data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
- data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
- data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
- data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
- data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
- data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
- data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
- data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
- data/lib/openstudio-standards/hvac/components/component.rb +39 -0
- data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
- data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
- data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
- data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
- data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
- data/lib/openstudio-standards/hvac/conversions.rb +222 -0
- data/lib/openstudio-standards/hvac/curves.rb +192 -0
- data/lib/openstudio-standards/hvac/helpers.rb +357 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
- data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
- data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
- data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
- data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
- data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
- data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
- data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
- data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
- data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
- data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
- data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
- data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
- data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
- data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
- data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
- data/lib/openstudio-standards/standards/Standards.Model.rb +6 -11
- data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
- data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
- data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +1 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
- data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
- data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +19 -10
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +69 -92
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +18 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +5 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +2 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +30 -141
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +233 -112
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
- data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +16 -4
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +65 -42
- data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
- data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/stat_file.rb +2 -2
- data/lib/openstudio-standards.rb +55 -38
- metadata +106 -66
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +0 -61
- data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +0 -1904
- data/lib/openstudio-standards/hvac/components/create.rb +0 -169
- data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
- data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
- data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
- data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
- data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/ConstructionProperties.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/Constructions.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/construction_sets.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/constructions_opaque.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/costs_local_factors.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/hvac_vent_ahu.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting_sets.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/locations.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_glazing.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_lighting.csv +0 -0
- /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_opaque.csv +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
- /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
|
@@ -8,7 +8,7 @@ class ASHRAE9012010 < ASHRAE901
|
|
|
8
8
|
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
9
9
|
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
11
|
-
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
11
|
+
min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
12
12
|
when 'Electricity', 'NaturalGas'
|
|
13
13
|
0.3
|
|
14
14
|
else # 'HotWater', other
|
|
@@ -8,7 +8,7 @@ class ASHRAE9012013 < ASHRAE901
|
|
|
8
8
|
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
9
9
|
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
11
|
-
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
11
|
+
min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
12
12
|
when 'Electricity', 'NaturalGas'
|
|
13
13
|
0.3
|
|
14
14
|
else # 'HotWater', other
|
|
@@ -8,7 +8,7 @@ class ASHRAE9012016 < ASHRAE901
|
|
|
8
8
|
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
9
9
|
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
11
|
-
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
11
|
+
min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
12
12
|
when 'Electricity', 'NaturalGas'
|
|
13
13
|
0.3
|
|
14
14
|
else # 'HotWater', other
|
data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb
CHANGED
|
@@ -300,7 +300,7 @@ class ASHRAE9012016 < ASHRAE901
|
|
|
300
300
|
key_name = space.name.to_s
|
|
301
301
|
end
|
|
302
302
|
light_sensor.setKeyName(key_name)
|
|
303
|
-
light_sensor_name_ems = "#{ems_friendly_name(key_name)}_LSr"
|
|
303
|
+
light_sensor_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_LSr"
|
|
304
304
|
light_sensor.setName(light_sensor_name_ems)
|
|
305
305
|
|
|
306
306
|
# get the space floor area for calculations
|
|
@@ -328,7 +328,7 @@ class ASHRAE9012016 < ASHRAE901
|
|
|
328
328
|
else
|
|
329
329
|
light_x_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(light_x, 'Lights', 'Electricity Rate')
|
|
330
330
|
end
|
|
331
|
-
light_x_actuator_name_ems = "#{ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
|
|
331
|
+
light_x_actuator_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
|
|
332
332
|
light_x_actuator.setName(light_x_actuator_name_ems)
|
|
333
333
|
add_lights_prog_null += "\n SET #{light_x_actuator_name_ems} = NULL,"
|
|
334
334
|
if light_x == big_light
|
|
@@ -339,7 +339,7 @@ class ASHRAE9012016 < ASHRAE901
|
|
|
339
339
|
end
|
|
340
340
|
|
|
341
341
|
light_ems_prog = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
|
342
|
-
light_ems_prog.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program")
|
|
342
|
+
light_ems_prog.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program")
|
|
343
343
|
light_ems_prog_body = <<-EMS
|
|
344
344
|
SET #{light_sensor_name_ems}_IP=0.093*#{light_sensor_name_ems}/#{space_floor_area},
|
|
345
345
|
IF (#{business_sensor_name} <= 0) && (#{light_sensor_name_ems}_IP >= 0.02),#{add_lights_prog_0}
|
|
@@ -349,7 +349,7 @@ class ASHRAE9012016 < ASHRAE901
|
|
|
349
349
|
light_ems_prog.setBody(light_ems_prog_body)
|
|
350
350
|
|
|
351
351
|
light_ems_prog_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
|
|
352
|
-
light_ems_prog_manager.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
|
|
352
|
+
light_ems_prog_manager.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
|
|
353
353
|
light_ems_prog_manager.setCallingPoint('AfterPredictorAfterHVACManagers')
|
|
354
354
|
light_ems_prog_manager.addProgram(light_ems_prog)
|
|
355
355
|
end
|
|
@@ -8,7 +8,7 @@ class ASHRAE9012019 < ASHRAE901
|
|
|
8
8
|
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
9
9
|
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
11
|
-
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
11
|
+
min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
12
12
|
when 'Electricity', 'NaturalGas'
|
|
13
13
|
0.3
|
|
14
14
|
else # 'HotWater', other
|
data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb
CHANGED
|
@@ -300,7 +300,7 @@ class ASHRAE9012019 < ASHRAE901
|
|
|
300
300
|
key_name = space.name.to_s
|
|
301
301
|
end
|
|
302
302
|
light_sensor.setKeyName(key_name)
|
|
303
|
-
light_sensor_name_ems = "#{ems_friendly_name(key_name)}_LSr"
|
|
303
|
+
light_sensor_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_LSr"
|
|
304
304
|
light_sensor.setName(light_sensor_name_ems)
|
|
305
305
|
|
|
306
306
|
# get the space floor area for calculations
|
|
@@ -328,7 +328,7 @@ class ASHRAE9012019 < ASHRAE901
|
|
|
328
328
|
else
|
|
329
329
|
light_x_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(light_x, 'Lights', 'Electricity Rate')
|
|
330
330
|
end
|
|
331
|
-
light_x_actuator_name_ems = "#{ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
|
|
331
|
+
light_x_actuator_name_ems = "#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light#{light_id}_Actuator"
|
|
332
332
|
light_x_actuator.setName(light_x_actuator_name_ems)
|
|
333
333
|
add_lights_prog_null += "\n SET #{light_x_actuator_name_ems} = NULL,"
|
|
334
334
|
if light_x == big_light
|
|
@@ -339,7 +339,7 @@ class ASHRAE9012019 < ASHRAE901
|
|
|
339
339
|
end
|
|
340
340
|
|
|
341
341
|
light_ems_prog = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
|
342
|
-
light_ems_prog.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program")
|
|
342
|
+
light_ems_prog.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program")
|
|
343
343
|
light_ems_prog_body = <<-EMS
|
|
344
344
|
SET #{light_sensor_name_ems}_IP=0.093*#{light_sensor_name_ems}/#{space_floor_area},
|
|
345
345
|
IF (#{business_sensor_name} <= 0) && (#{light_sensor_name_ems}_IP >= 0.02),#{add_lights_prog_0}
|
|
@@ -349,7 +349,7 @@ class ASHRAE9012019 < ASHRAE901
|
|
|
349
349
|
light_ems_prog.setBody(light_ems_prog_body)
|
|
350
350
|
|
|
351
351
|
light_ems_prog_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
|
|
352
|
-
light_ems_prog_manager.setName("SET_#{ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
|
|
352
|
+
light_ems_prog_manager.setName("SET_#{OpenstudioStandards::HVAC.ems_friendly_name(key_name)}_Light_EMS_Program_Manager")
|
|
353
353
|
light_ems_prog_manager.setCallingPoint('AfterPredictorAfterHVACManagers')
|
|
354
354
|
light_ems_prog_manager.addProgram(light_ems_prog)
|
|
355
355
|
end
|
|
@@ -8,7 +8,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
8
8
|
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
9
9
|
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
11
|
-
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
11
|
+
min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
12
12
|
when 'HotWater'
|
|
13
13
|
0.2
|
|
14
14
|
when 'Electricity', 'NaturalGas'
|
|
@@ -8,7 +8,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
8
8
|
# @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
|
|
9
9
|
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
|
|
11
|
-
min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
11
|
+
min_damper_position = case OpenstudioStandards::HVAC.air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
|
|
12
12
|
when 'HotWater'
|
|
13
13
|
0.2
|
|
14
14
|
when 'Electricity', 'NaturalGas'
|
|
@@ -37,13 +37,12 @@ module HighriseApartment
|
|
|
37
37
|
'Electric Equipment Electricity Energy'
|
|
38
38
|
end
|
|
39
39
|
|
|
40
|
-
|
|
41
|
-
|
|
42
|
-
|
|
43
|
-
|
|
44
|
-
|
|
45
|
-
|
|
46
|
-
|
|
40
|
+
OpenstudioStandards::Equipment.create_transformer(model,
|
|
41
|
+
wired_lighting_frac: 0.0015,
|
|
42
|
+
transformer_size: 75000,
|
|
43
|
+
transformer_efficiency: transformer_efficiency,
|
|
44
|
+
excluded_interiorequip_key: 'T Corridor_Elevators_Equip',
|
|
45
|
+
excluded_interiorequip_meter: excluded_interiorequip_variable)
|
|
47
46
|
return true
|
|
48
47
|
end
|
|
49
48
|
|
|
@@ -25,10 +25,10 @@ module Hospital
|
|
|
25
25
|
end
|
|
26
26
|
|
|
27
27
|
unless transformer_efficiency.nil?
|
|
28
|
-
|
|
29
|
-
|
|
30
|
-
|
|
31
|
-
|
|
28
|
+
OpenstudioStandards::Equipment.create_transformer(model,
|
|
29
|
+
wired_lighting_frac: 0.022,
|
|
30
|
+
transformer_size: 500000,
|
|
31
|
+
transformer_efficiency: transformer_efficiency)
|
|
32
32
|
end
|
|
33
33
|
|
|
34
34
|
# add extra equipment for kitchen
|
|
@@ -85,10 +85,10 @@ module Hospital
|
|
|
85
85
|
|
|
86
86
|
# replace main supply air fan
|
|
87
87
|
air_loop.supplyFan.get.remove
|
|
88
|
-
fan =
|
|
89
|
-
|
|
90
|
-
|
|
91
|
-
|
|
88
|
+
fan = OpenstudioStandards::HVAC.create_typical_fan(model,
|
|
89
|
+
'Hospital_CAV_Sytem_Fan',
|
|
90
|
+
fan_name: "#{air_loop.name} Fan",
|
|
91
|
+
end_use_subcategory: 'CAV System Fans')
|
|
92
92
|
fan.setAvailabilitySchedule(model.alwaysOnDiscreteSchedule)
|
|
93
93
|
fan.addToNode(air_loop.supplyOutletNode)
|
|
94
94
|
|
|
@@ -276,13 +276,13 @@ module Hospital
|
|
|
276
276
|
humidity_spm = OpenStudio::Model::SetpointManagerSingleZoneHumidityMinimum.new(model)
|
|
277
277
|
case template
|
|
278
278
|
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
|
279
|
-
create_coil_heating_electric(model,
|
|
280
|
-
|
|
281
|
-
|
|
282
|
-
create_coil_heating_water(model,
|
|
283
|
-
|
|
284
|
-
|
|
285
|
-
|
|
279
|
+
OpenstudioStandards::HVAC.create_coil_heating_electric(model,
|
|
280
|
+
air_loop_node: supply_outlet_node,
|
|
281
|
+
name: "#{space_name} Electric Htg Coil")
|
|
282
|
+
OpenstudioStandards::HVAC.create_coil_heating_water(model,
|
|
283
|
+
hot_water_loop,
|
|
284
|
+
air_loop_node: supply_outlet_node,
|
|
285
|
+
name: "#{space_name} Water Htg Coil")
|
|
286
286
|
end
|
|
287
287
|
# humidity_spm.addToNode(supply_outlet_node)
|
|
288
288
|
humidity_spm.addToNode(humidifier.outletModelObject.get.to_Node.get)
|
|
@@ -25,10 +25,10 @@ module LargeHotel
|
|
|
25
25
|
end
|
|
26
26
|
return true if transformer_efficiency.nil?
|
|
27
27
|
|
|
28
|
-
|
|
29
|
-
|
|
30
|
-
|
|
31
|
-
|
|
28
|
+
OpenstudioStandards::Equipment.create_transformer(model,
|
|
29
|
+
wired_lighting_frac: 0.0352,
|
|
30
|
+
transformer_size: 150000,
|
|
31
|
+
transformer_efficiency: transformer_efficiency)
|
|
32
32
|
|
|
33
33
|
# add extra equipment for kitchen
|
|
34
34
|
add_extra_equip_kitchen(model)
|
|
@@ -32,11 +32,11 @@ module LargeOffice
|
|
|
32
32
|
end
|
|
33
33
|
end
|
|
34
34
|
|
|
35
|
-
|
|
36
|
-
|
|
37
|
-
|
|
38
|
-
|
|
39
|
-
|
|
35
|
+
OpenstudioStandards::Equipment.create_transformer(model,
|
|
36
|
+
wired_lighting_frac: 0.0281,
|
|
37
|
+
transformer_size: 500000,
|
|
38
|
+
transformer_efficiency: transformer_efficiency,
|
|
39
|
+
excluded_interiorequip_meter: 'DataCenterPlugLoads:InteriorEquipment:Electricity')
|
|
40
40
|
|
|
41
41
|
system_to_space_map = define_hvac_system_map(building_type, climate_zone)
|
|
42
42
|
|
|
@@ -32,12 +32,12 @@ module MediumOffice
|
|
|
32
32
|
'Electric Equipment Electricity Energy'
|
|
33
33
|
end
|
|
34
34
|
|
|
35
|
-
|
|
36
|
-
|
|
37
|
-
|
|
38
|
-
|
|
39
|
-
|
|
40
|
-
|
|
35
|
+
OpenstudioStandards::Equipment.create_transformer(model,
|
|
36
|
+
wired_lighting_frac: 0.0281,
|
|
37
|
+
transformer_size: 45000,
|
|
38
|
+
transformer_efficiency: transformer_efficiency,
|
|
39
|
+
excluded_interiorequip_key: '2 Elevator Lift Motors',
|
|
40
|
+
excluded_interiorequip_meter: excluded_interiorequip_variable)
|
|
41
41
|
|
|
42
42
|
model.getSpaces.sort.each do |space|
|
|
43
43
|
if space.name.get.to_s == 'Core_bottom'
|
|
@@ -273,13 +273,13 @@ module Outpatient
|
|
|
273
273
|
humidity_spm = OpenStudio::Model::SetpointManagerSingleZoneHumidityMinimum.new(model)
|
|
274
274
|
case template
|
|
275
275
|
when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013', '90.1-2016', '90.1-2019'
|
|
276
|
-
create_coil_heating_electric(model,
|
|
277
|
-
|
|
278
|
-
|
|
279
|
-
create_coil_heating_water(model,
|
|
280
|
-
|
|
281
|
-
|
|
282
|
-
|
|
276
|
+
OpenstudioStandards::HVAC.create_coil_heating_electric(model,
|
|
277
|
+
air_loop_node: supply_outlet_node,
|
|
278
|
+
name: 'AHU1 extra Electric Htg Coil')
|
|
279
|
+
OpenstudioStandards::HVAC.create_coil_heating_water(model,
|
|
280
|
+
hot_water_loop,
|
|
281
|
+
air_loop_node: supply_outlet_node,
|
|
282
|
+
name: 'AHU1 extra Water Htg Coil')
|
|
283
283
|
end
|
|
284
284
|
# humidity_spm.addToNode(supply_outlet_node)
|
|
285
285
|
humidity_spm.addToNode(humidifier.outletModelObject.get.to_Node.get)
|
|
@@ -25,10 +25,10 @@ module PrimarySchool
|
|
|
25
25
|
end
|
|
26
26
|
return true if transformer_efficiency.nil?
|
|
27
27
|
|
|
28
|
-
|
|
29
|
-
|
|
30
|
-
|
|
31
|
-
|
|
28
|
+
OpenstudioStandards::Equipment.create_transformer(model,
|
|
29
|
+
wired_lighting_frac: 0.0119,
|
|
30
|
+
transformer_size: 112500,
|
|
31
|
+
transformer_efficiency: transformer_efficiency)
|
|
32
32
|
|
|
33
33
|
# add extra equipment for kitchen
|
|
34
34
|
add_extra_equip_kitchen(model)
|
|
@@ -32,12 +32,12 @@ module SecondarySchool
|
|
|
32
32
|
'Electric Equipment Electricity Energy'
|
|
33
33
|
end
|
|
34
34
|
|
|
35
|
-
|
|
36
|
-
|
|
37
|
-
|
|
38
|
-
|
|
39
|
-
|
|
40
|
-
|
|
35
|
+
OpenstudioStandards::Equipment.create_transformer(model,
|
|
36
|
+
wired_lighting_frac: 0.0194,
|
|
37
|
+
transformer_size: 225000,
|
|
38
|
+
transformer_efficiency: transformer_efficiency,
|
|
39
|
+
excluded_interiorequip_key: '2 Elevator Lift Motors',
|
|
40
|
+
excluded_interiorequip_meter: excluded_interiorequip_variable)
|
|
41
41
|
|
|
42
42
|
# add extra equipment for kitchen
|
|
43
43
|
add_extra_equip_kitchen(model)
|
|
@@ -68,7 +68,11 @@ module SmallOfficeDetailed
|
|
|
68
68
|
# add extra infiltration for attic in m3/s (there is no attic in 'DOE Ref Pre-1980')
|
|
69
69
|
return false if template == 'DOE Ref 1980-2004' || template == 'DOE Ref Pre-1980'
|
|
70
70
|
|
|
71
|
-
|
|
71
|
+
if model.getSpaceByName('Attic').is_initialized
|
|
72
|
+
entry_space = model.getSpaceByName('Attic').get
|
|
73
|
+
elsif model.getSpaceByName('Attic 1').is_initialized
|
|
74
|
+
entry_space = model.getSpaceByName('Attic 1').get
|
|
75
|
+
end
|
|
72
76
|
infiltration_attic = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
|
73
77
|
infiltration_attic.setName('attic Infiltration')
|
|
74
78
|
infiltration_per_zone_attic = 0.2001
|