openstudio-standards 0.8.4 → 0.8.5.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (289) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.osm +30 -30
  3. data/data/geometry/ASHRAECourthouse.osm +22 -22
  4. data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
  5. data/data/geometry/DEER_Asm.osm +1 -1
  6. data/data/geometry/DEER_ECC.osm +1 -1
  7. data/data/geometry/DEER_EPr.osm +1 -1
  8. data/data/geometry/DEER_ERC.osm +1 -1
  9. data/data/geometry/DEER_ESe.osm +1 -1
  10. data/data/geometry/DEER_EUn.osm +1 -1
  11. data/data/geometry/DEER_Hsp.osm +1 -1
  12. data/data/geometry/DEER_Htl.osm +1 -1
  13. data/data/geometry/DEER_MBT.osm +1 -1
  14. data/data/geometry/DEER_MFm.osm +1 -1
  15. data/data/geometry/DEER_Nrs.osm +1 -1
  16. data/data/geometry/DEER_OfL.osm +1 -1
  17. data/data/geometry/DEER_OfS.osm +1 -1
  18. data/data/geometry/DEER_RFF.osm +1 -1
  19. data/data/geometry/DEER_RSD.osm +1 -1
  20. data/data/geometry/DEER_Rt3.osm +1 -1
  21. data/data/geometry/DEER_RtS.osm +1 -1
  22. data/data/standards/export_OpenStudio_libraries.rb +2 -3
  23. data/data/standards/test_performance_expected_dd_results.csv +42 -42
  24. data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
  25. data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
  26. data/lib/openstudio-standards/btap/activity.rb +480 -0
  27. data/lib/openstudio-standards/btap/attributes.rb +166 -0
  28. data/lib/openstudio-standards/btap/bridging.rb +561 -1402
  29. data/lib/openstudio-standards/btap/btap.rb +4 -2
  30. data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
  31. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
  32. data/lib/openstudio-standards/btap/{costing/common_paths.rb → common_paths.rb} +14 -11
  33. data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
  34. data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
  35. data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
  36. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
  37. data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
  38. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting.csv +59 -59
  39. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_hvac.csv +1019 -1032
  40. data/lib/openstudio-standards/btap/costing/btap_costing.rb +3 -7
  41. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +1 -5
  42. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +5 -4
  43. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +1 -1
  44. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +112 -181
  45. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +4 -4
  46. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +2 -1
  47. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +3 -3
  48. data/lib/openstudio-standards/btap/costing/test_list.txt +15 -17
  49. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +10 -9
  50. data/lib/openstudio-standards/btap/geometry.rb +86 -6
  51. data/lib/openstudio-standards/btap/structure.rb +657 -0
  52. data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
  53. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
  54. data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
  55. data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
  56. data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
  57. data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
  58. data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
  59. data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
  60. data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
  61. data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
  62. data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
  63. data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
  64. data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
  65. data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
  66. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
  67. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
  68. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
  69. data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
  70. data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
  71. data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
  72. data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
  73. data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
  74. data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
  75. data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
  76. data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
  77. data/lib/openstudio-standards/hvac/components/component.rb +39 -0
  78. data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
  79. data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
  80. data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
  81. data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
  82. data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
  83. data/lib/openstudio-standards/hvac/conversions.rb +222 -0
  84. data/lib/openstudio-standards/hvac/curves.rb +192 -0
  85. data/lib/openstudio-standards/hvac/helpers.rb +357 -0
  86. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
  87. data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
  88. data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
  89. data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
  90. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
  91. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
  92. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
  93. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  99. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
  100. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  101. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  102. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
  103. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
  111. data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
  112. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
  113. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
  114. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
  115. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
  116. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
  117. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
  118. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
  119. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
  120. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
  121. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
  122. data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
  123. data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
  124. data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
  125. data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
  126. data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
  127. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
  128. data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
  129. data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
  130. data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
  131. data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
  132. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
  133. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
  134. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
  135. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
  136. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
  137. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
  138. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
  139. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
  140. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
  141. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
  142. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
  143. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
  144. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
  145. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
  146. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
  147. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
  148. data/lib/openstudio-standards/standards/Standards.Model.rb +6 -11
  149. data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
  150. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
  151. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
  152. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
  153. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
  154. data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
  155. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
  156. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
  157. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
  158. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
  159. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
  160. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
  161. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
  162. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  163. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
  164. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
  165. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
  166. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  167. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
  168. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
  169. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
  170. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
  171. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  172. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
  182. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
  183. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
  184. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
  185. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
  186. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
  187. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
  188. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  189. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  191. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
  192. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
  193. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
  194. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
  195. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
  196. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
  197. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
  198. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
  199. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
  200. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
  202. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
  203. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
  204. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
  205. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +1 -0
  206. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
  207. data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
  208. data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
  209. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +19 -10
  210. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
  211. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
  212. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
  213. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +69 -92
  214. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +2 -1
  215. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
  216. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
  217. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
  218. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +32 -0
  219. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +18 -0
  220. data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
  221. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +5 -5
  222. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +2 -0
  223. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +30 -141
  224. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +233 -112
  225. data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
  226. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -2
  227. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
  228. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
  229. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
  230. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
  231. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +16 -4
  232. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +65 -42
  233. data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
  234. data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
  235. data/lib/openstudio-standards/version.rb +1 -1
  236. data/lib/openstudio-standards/weather/stat_file.rb +2 -2
  237. data/lib/openstudio-standards.rb +55 -38
  238. metadata +106 -66
  239. data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +0 -61
  240. data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +0 -1904
  241. data/lib/openstudio-standards/hvac/components/create.rb +0 -169
  242. data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
  243. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
  244. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
  245. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
  246. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
  247. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
  248. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
  249. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
  250. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
  251. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
  252. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
  253. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
  254. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
  255. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
  256. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
  257. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
  258. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
  259. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
  260. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
  261. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
  262. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
  263. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
  264. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
  265. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
  266. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
  267. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
  268. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
  269. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
  270. data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
  271. data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
  272. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/ConstructionProperties.csv +0 -0
  273. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/Constructions.csv +0 -0
  274. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/construction_sets.csv +0 -0
  275. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/constructions_opaque.csv +0 -0
  276. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/costs_local_factors.csv +0 -0
  277. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/hvac_vent_ahu.csv +0 -0
  278. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting_sets.csv +0 -0
  279. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/locations.csv +0 -0
  280. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_glazing.csv +0 -0
  281. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_lighting.csv +0 -0
  282. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_opaque.csv +0 -0
  283. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
  284. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
  285. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
  286. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
  287. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
  288. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
  289. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
@@ -0,0 +1,181 @@
1
+ module OpenstudioStandards
2
+ # The HVAC module provides methods create, modify, and get information about HVAC systems in the model
3
+ module HVAC
4
+ # @!group Component:Pump
5
+ # Methods to create, modify, and get information about pumps
6
+
7
+ # Get the pump flow rate (whether autosized or hard-sized)
8
+ #
9
+ # @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types: PumpConstantSpeed, PumpVariableSpeed, HeaderedPumpsConstantSpeed, HeaderedPumpsVariableSpeed
10
+ # return [Double] flow rate in m^3/s
11
+ def self.pump_get_rated_flow_rate(pump)
12
+ flow_m3_per_s = 0.0
13
+ if pump.to_PumpVariableSpeed.is_initialized || pump.to_PumpConstantSpeed.is_initialized
14
+ if pump.ratedFlowRate.is_initialized
15
+ flow_m3_per_s = pump.ratedFlowRate.get
16
+ elsif pump.autosizedRatedFlowRate.is_initialized
17
+ flow_m3_per_s = pump.autosizedRatedFlowRate.get
18
+ else
19
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.HVAC.pump', "For #{pump.name}, could not find rated pump Flow Rate.")
20
+ end
21
+ elsif pump.to_HeaderedPumpsVariableSpeed.is_initialized || pump.to_HeaderedPumpsConstantSpeed.is_initialized
22
+ if pump.totalRatedFlowRate.is_initialized
23
+ flow_m3_per_s = pump.totalRatedFlowRate.get
24
+ elsif pump.autosizedTotalRatedFlowRate.is_initialized
25
+ flow_m3_per_s = pump.autosizedTotalRatedFlowRate.get
26
+ else
27
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.HVAC.pump', "For #{pump.name}, could not find rated pump Flow Rate.")
28
+ end
29
+ end
30
+
31
+ return flow_m3_per_s
32
+ end
33
+
34
+ # Determines the pump power (W) based on flow rate, pressure rise,
35
+ # and total pump efficiency(impeller eff * motor eff).
36
+ # Uses the E+ default assumption of 0.78 impeller efficiency.
37
+ #
38
+ # @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
39
+ # PumpConstantSpeed, PumpVariableSpeed
40
+ # @return [Double] pump power in watts
41
+ def self.pump_get_power(pump)
42
+ # Get flow rate (whether autosized or hard-sized)
43
+ flow_m3_per_s = OpenstudioStandards::HVAC.pump_get_rated_flow_rate(pump)
44
+
45
+ # E+ default impeller efficiency
46
+ # http://bigladdersoftware.com/epx/docs/8-4/engineering-reference/component-sizing.html#pump-sizing
47
+ impeller_eff = 0.78
48
+
49
+ # Get the motor efficiency
50
+ motor_eff = pump.motorEfficiency
51
+
52
+ # Calculate the total efficiency
53
+ # which includes both motor and
54
+ # impeller efficiency.
55
+ pump_total_eff = impeller_eff * motor_eff
56
+
57
+ # Get the pressure rise (Pa)
58
+ pressure_rise_pa = pump.ratedPumpHead
59
+
60
+ # Calculate the pump power (W)
61
+ pump_power_w = pressure_rise_pa * flow_m3_per_s / pump_total_eff
62
+
63
+ return pump_power_w
64
+ end
65
+
66
+ # Determines the brake horsepower of the pump based on flow rate,
67
+ # pressure rise, and impeller efficiency.
68
+ #
69
+ # @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
70
+ # PumpConstantSpeed, PumpVariableSpeed
71
+ # @return [Double] brake horsepower
72
+ def self.pump_get_brake_horsepower(pump)
73
+ # Get flow rate (whether autosized or hard-sized)
74
+ flow_m3_per_s = OpenstudioStandards::HVAC.pump_get_rated_flow_rate(pump)
75
+
76
+ # E+ default impeller efficiency
77
+ # http://bigladdersoftware.com/epx/docs/8-4/engineering-reference/component-sizing.html#pump-sizing
78
+ impeller_eff = 0.78
79
+
80
+ # Get the pressure rise (Pa)
81
+ pressure_rise_pa = pump.ratedPumpHead
82
+
83
+ # Calculate the pump power (W)
84
+ pump_power_w = pressure_rise_pa * flow_m3_per_s / impeller_eff
85
+
86
+ # Convert to HP
87
+ pump_power_hp = pump_power_w / 745.7 # 745.7 W/HP
88
+
89
+ return pump_power_hp
90
+ end
91
+
92
+ # Determines the horsepower of the pump motor, including motor efficiency and pump impeller efficiency.
93
+ #
94
+ # @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
95
+ # PumpConstantSpeed, PumpVariableSpeed
96
+ # @return [Double] motor horsepower
97
+ def self.pump_get_motor_horsepower(pump)
98
+ # Get the pump power
99
+ pump_power_w = OpenstudioStandards::HVAC.pump_get_power(pump)
100
+
101
+ # Convert to HP
102
+ pump_hp = pump_power_w / 745.7 # 745.7 W/HP
103
+
104
+ return pump_hp
105
+ end
106
+
107
+ # Determines the rated watts per GPM of the pump
108
+ #
109
+ # @param pump [OpenStudio::Model::StraightComponent] pump object, allowable types:
110
+ # PumpConstantSpeed, PumpVariableSpeed
111
+ # @return [Double] rated power consumption per flow in watts per gpm, W*min/gal
112
+ def self.pump_get_rated_w_per_gpm(pump)
113
+ # Get design power (whether autosized or hard-sized)
114
+ rated_power_w = 0
115
+ if pump.ratedPowerConsumption.is_initialized
116
+ rated_power_w = pump.ratedPowerConsumption.get
117
+ elsif pump.autosizedRatedPowerConsumption.is_initialized
118
+ rated_power_w = pump.autosizedRatedPowerConsumption.get
119
+ else
120
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.HVAC.pump', "For #{pump.name}, could not find rated pump power consumption, cannot determine w per gpm correctly.")
121
+ return 0.0
122
+ end
123
+
124
+ rated_m3_per_s = OpenstudioStandards::HVAC.pump_get_rated_flow_rate(pump)
125
+ rated_w_per_m3s = rated_power_w / rated_m3_per_s
126
+ rated_w_per_gpm = OpenStudio.convert(rated_w_per_m3s, 'W*s/m^3', 'W*min/gal').get
127
+
128
+ return rated_w_per_gpm
129
+ end
130
+
131
+ # Set the pump curve coefficients based on the specified control type.
132
+ #
133
+ # @param pump_variable_speed [OpenStudio::Model::PumpVariableSpeed, OpenStudio::Model::HeaderedPumpsVariableSpeed] variable speed pump or headered variable speed pumps object
134
+ # @param control_type [String] valid choices are Riding Curve, VSD No Reset, VSD DP Reset
135
+ # @return [Boolean] returns true if successful, false if not
136
+ def self.pump_variable_speed_set_control_type(pump_variable_speed, control_type: 'Riding Curve')
137
+ # Determine the coefficients
138
+ coeff_a = nil
139
+ coeff_b = nil
140
+ coeff_c = nil
141
+ coeff_d = nil
142
+ case control_type
143
+ when 'Constant Flow'
144
+ coeff_a = 0.0
145
+ coeff_b = 1.0
146
+ coeff_c = 0.0
147
+ coeff_d = 0.0
148
+ when 'Riding Curve'
149
+ coeff_a = 0.0
150
+ coeff_b = 3.2485
151
+ coeff_c = -4.7443
152
+ coeff_d = 2.5294
153
+ when 'VSD No Reset'
154
+ coeff_a = 0.0
155
+ coeff_b = 0.5726
156
+ coeff_c = -0.301
157
+ coeff_d = 0.7347
158
+ when 'VSD DP Reset'
159
+ coeff_a = 0.0
160
+ coeff_b = 0.0205
161
+ coeff_c = 0.4101
162
+ coeff_d = 0.5753
163
+ else
164
+ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.HVAC.pump', "Pump control type '#{control_type}' not recognized, pump coefficients will not be changed.")
165
+ return false
166
+ end
167
+
168
+ # Set the coefficients
169
+ pump_variable_speed.setCoefficient1ofthePartLoadPerformanceCurve(coeff_a)
170
+ pump_variable_speed.setCoefficient2ofthePartLoadPerformanceCurve(coeff_b)
171
+ pump_variable_speed.setCoefficient3ofthePartLoadPerformanceCurve(coeff_c)
172
+ pump_variable_speed.setCoefficient4ofthePartLoadPerformanceCurve(coeff_d)
173
+ pump_variable_speed.setPumpControlType('Intermittent')
174
+
175
+ # Append the control type to the pump name
176
+ # self.setName("#{self.name} #{control_type}")
177
+
178
+ return true
179
+ end
180
+ end
181
+ end