openstudio-standards 0.8.4 → 0.8.5.rc1

This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
Files changed (289) hide show
  1. checksums.yaml +4 -4
  2. data/data/geometry/ASHRAECollege.osm +30 -30
  3. data/data/geometry/ASHRAECourthouse.osm +22 -22
  4. data/data/geometry/ASHRAESmallOfficeDetailed.osm +2 -2
  5. data/data/geometry/DEER_Asm.osm +1 -1
  6. data/data/geometry/DEER_ECC.osm +1 -1
  7. data/data/geometry/DEER_EPr.osm +1 -1
  8. data/data/geometry/DEER_ERC.osm +1 -1
  9. data/data/geometry/DEER_ESe.osm +1 -1
  10. data/data/geometry/DEER_EUn.osm +1 -1
  11. data/data/geometry/DEER_Hsp.osm +1 -1
  12. data/data/geometry/DEER_Htl.osm +1 -1
  13. data/data/geometry/DEER_MBT.osm +1 -1
  14. data/data/geometry/DEER_MFm.osm +1 -1
  15. data/data/geometry/DEER_Nrs.osm +1 -1
  16. data/data/geometry/DEER_OfL.osm +1 -1
  17. data/data/geometry/DEER_OfS.osm +1 -1
  18. data/data/geometry/DEER_RFF.osm +1 -1
  19. data/data/geometry/DEER_RSD.osm +1 -1
  20. data/data/geometry/DEER_Rt3.osm +1 -1
  21. data/data/geometry/DEER_RtS.osm +1 -1
  22. data/data/standards/export_OpenStudio_libraries.rb +2 -3
  23. data/data/standards/test_performance_expected_dd_results.csv +42 -42
  24. data/lib/openstudio-standards/btap/NECB_building_types.csv +35 -0
  25. data/lib/openstudio-standards/btap/NECB_space_types.csv +109 -0
  26. data/lib/openstudio-standards/btap/activity.rb +480 -0
  27. data/lib/openstudio-standards/btap/attributes.rb +166 -0
  28. data/lib/openstudio-standards/btap/bridging.rb +561 -1402
  29. data/lib/openstudio-standards/btap/btap.rb +4 -2
  30. data/lib/openstudio-standards/btap/btap_test_helper.rb +86 -0
  31. data/lib/openstudio-standards/btap/carbon/btap_carbon.rb +177 -0
  32. data/lib/openstudio-standards/btap/{costing/common_paths.rb → common_paths.rb} +14 -11
  33. data/lib/openstudio-standards/btap/common_resources/carbon_frame.csv +35 -0
  34. data/lib/openstudio-standards/btap/common_resources/carbon_glazing.csv +35 -0
  35. data/lib/openstudio-standards/btap/common_resources/carbon_opaque.csv +164 -0
  36. data/lib/openstudio-standards/btap/common_resources/constructions_glazing.csv +121 -0
  37. data/lib/openstudio-standards/btap/common_resources/costs.csv +1897 -0
  38. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting.csv +59 -59
  39. data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_hvac.csv +1019 -1032
  40. data/lib/openstudio-standards/btap/costing/btap_costing.rb +3 -7
  41. data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +1 -5
  42. data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +5 -4
  43. data/lib/openstudio-standards/btap/costing/dcv_costing.rb +1 -1
  44. data/lib/openstudio-standards/btap/costing/envelope_costing.rb +112 -181
  45. data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +4 -4
  46. data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +2 -1
  47. data/lib/openstudio-standards/btap/costing/lighting_costing.rb +3 -3
  48. data/lib/openstudio-standards/btap/costing/test_list.txt +15 -17
  49. data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +10 -9
  50. data/lib/openstudio-standards/btap/geometry.rb +86 -6
  51. data/lib/openstudio-standards/btap/structure.rb +657 -0
  52. data/lib/openstudio-standards/create_typical/create_typical.rb +17 -33
  53. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +36 -36
  54. data/lib/openstudio-standards/equipment/create_transformer.rb +104 -0
  55. data/lib/openstudio-standards/equipment/create_typical_equipment.rb +117 -0
  56. data/lib/openstudio-standards/equipment/data/electric_equipment_space_types.json +1514 -0
  57. data/lib/openstudio-standards/equipment/data/gas_equipment_space_types.json +227 -0
  58. data/lib/openstudio-standards/exterior_lighting/create.rb +22 -22
  59. data/lib/openstudio-standards/exterior_lighting/information.rb +3 -2
  60. data/lib/openstudio-standards/hvac/components/air_conditioner_vrf.rb +482 -0
  61. data/lib/openstudio-standards/hvac/components/air_terminal.rb +31 -0
  62. data/lib/openstudio-standards/hvac/components/boiler_hot_water.rb +163 -0
  63. data/lib/openstudio-standards/hvac/components/central_air_source_heat_pump.rb +220 -0
  64. data/lib/openstudio-standards/hvac/components/chiller.rb +25 -0
  65. data/lib/openstudio-standards/hvac/components/coil.rb +276 -0
  66. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_multi_speed.rb +40 -0
  67. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_single_speed.rb +300 -0
  68. data/lib/openstudio-standards/hvac/components/coil_cooling_dx_two_speed.rb +187 -0
  69. data/lib/openstudio-standards/hvac/components/coil_cooling_water.rb +80 -0
  70. data/lib/openstudio-standards/hvac/components/coil_cooling_water_to_air_heat_pump_equation_fit.rb +182 -0
  71. data/lib/openstudio-standards/hvac/components/coil_heating_dx_single_speed.rb +220 -0
  72. data/lib/openstudio-standards/hvac/components/coil_heating_electric.rb +56 -0
  73. data/lib/openstudio-standards/hvac/components/coil_heating_gas.rb +90 -0
  74. data/lib/openstudio-standards/hvac/components/coil_heating_gas_multi_stage.rb +33 -0
  75. data/lib/openstudio-standards/hvac/components/coil_heating_water.rb +98 -0
  76. data/lib/openstudio-standards/hvac/components/coil_heating_water_to_air_heat_pump_equation_fit.rb +147 -0
  77. data/lib/openstudio-standards/hvac/components/component.rb +39 -0
  78. data/lib/openstudio-standards/{standards/ashrae_90_1/data/ashrae_90_1.fans.json → hvac/components/data/fans.json} +6 -6
  79. data/lib/openstudio-standards/hvac/components/fan.rb +363 -0
  80. data/lib/openstudio-standards/hvac/components/heat_exchanger_air_to_air.rb +203 -0
  81. data/lib/openstudio-standards/hvac/components/pump.rb +181 -0
  82. data/lib/openstudio-standards/hvac/controls/radiant_system_controls.rb +594 -0
  83. data/lib/openstudio-standards/hvac/conversions.rb +222 -0
  84. data/lib/openstudio-standards/hvac/curves.rb +192 -0
  85. data/lib/openstudio-standards/hvac/helpers.rb +357 -0
  86. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +4 -4
  87. data/lib/openstudio-standards/interior_lighting/create_lights.rb +52 -0
  88. data/lib/openstudio-standards/interior_lighting/create_typical_interior_lighting.rb +254 -0
  89. data/lib/openstudio-standards/interior_lighting/data/convert_lighting_data.rb +249 -0
  90. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.csv +96 -0
  91. data/lib/openstudio-standards/interior_lighting/data/lighting_space_types.json +1429 -0
  92. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.csv +46 -0
  93. data/lib/openstudio-standards/interior_lighting/data/lighting_technology.json +859 -0
  94. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  95. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  96. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  97. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -4
  98. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  99. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -4
  100. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  101. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  102. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +6 -7
  103. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +15 -15
  104. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +4 -4
  105. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +5 -5
  106. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +6 -6
  107. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +7 -7
  108. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +4 -4
  109. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +6 -6
  110. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +5 -1
  111. data/lib/openstudio-standards/prototypes/common/data/prototype_space_type_map.json +2594 -0
  112. data/lib/openstudio-standards/prototypes/common/data/thermostat_schedule_lookup.json +2108 -0
  113. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +33 -0
  114. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +0 -140
  115. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -73
  116. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -69
  117. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +0 -116
  118. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +0 -61
  119. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +2 -2
  120. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +128 -13
  121. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +606 -607
  122. data/lib/openstudio-standards/prototypes/common/prototype_space_type_map.rb +41 -0
  123. data/lib/openstudio-standards/prototypes/common/space_type_equipment_map.rb +184 -0
  124. data/lib/openstudio-standards/prototypes/common/space_type_thermostat_schedule_map.rb +116 -0
  125. data/lib/openstudio-standards/qaqc/hvac.rb +12 -12
  126. data/lib/openstudio-standards/refrigeration/create_compressor.rb +2 -5
  127. data/lib/openstudio-standards/refrigeration/data/refrigeration_compressors.csv +4 -4
  128. data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +1 -2
  129. data/lib/openstudio-standards/service_water_heating/create_water_use.rb +5 -5
  130. data/lib/openstudio-standards/space_type/data/level_1_space_types.json +612 -0
  131. data/lib/openstudio-standards/space_type/standards_space_type.rb +53 -0
  132. data/lib/openstudio-standards/standards/Standards.AirConditionerVariableRefrigerantFlow.rb +8 -26
  133. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +13 -13
  134. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +0 -24
  135. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +6 -43
  136. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +7 -24
  137. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +19 -44
  138. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +25 -50
  139. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +25 -33
  140. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +9 -22
  141. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +15 -157
  142. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +2 -2
  143. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +18 -105
  144. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +3 -23
  145. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +0 -24
  146. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -86
  147. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +0 -107
  148. data/lib/openstudio-standards/standards/Standards.Model.rb +6 -11
  149. data/lib/openstudio-standards/standards/Standards.People.rb +113 -0
  150. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +11 -11
  151. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -147
  152. data/lib/openstudio-standards/standards/Standards.PumpVariableSpeed.rb +57 -41
  153. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +30 -153
  154. data/lib/openstudio-standards/standards/Standards.Ventilation.rb +74 -0
  155. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +1 -1
  156. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +4 -4
  157. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +3 -3
  158. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +37 -112
  159. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +37 -102
  160. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +3 -3
  161. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +37 -112
  162. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  163. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +37 -37
  164. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +6 -6
  165. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +37 -37
  166. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  167. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.BoilerHotWater.rb +1 -1
  168. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +37 -102
  169. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +6 -6
  170. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +37 -37
  171. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  172. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.BoilerHotWater.rb +1 -1
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.spc_typ.json +45 -109
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +6 -6
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.spc_typ.json +37 -37
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +1 -1
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.BoilerHotWater.rb +1 -1
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoilHeatingGas.rb +1 -1
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.spc_typ.json +45 -109
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +6 -6
  182. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.spc_typ.json +37 -37
  183. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +0 -200
  184. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +37 -37
  185. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +37 -37
  186. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +37 -37
  187. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +37 -37
  188. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  189. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +5 -5
  190. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  191. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +5 -5
  192. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +1 -1
  193. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +2 -2
  194. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -68
  195. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +2 -35
  196. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +42 -0
  197. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +5 -2
  198. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +2 -2
  199. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +3 -3
  200. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +1 -0
  202. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019_WaterHeaterMixed.rb +2 -4
  203. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.curves.json +0 -200
  204. data/lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json +5 -5
  205. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +1 -0
  206. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +0 -1
  207. data/lib/openstudio-standards/standards/cbes/data/cbes.curves.json +0 -200
  208. data/lib/openstudio-standards/standards/deer/data/deer.curves.json +0 -200
  209. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +19 -10
  210. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +12 -11
  211. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +4 -4
  212. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +1 -1
  213. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +69 -92
  214. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +2 -1
  215. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +16 -12
  216. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +799 -46
  217. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +33 -51
  218. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +32 -0
  219. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +18 -0
  220. data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +21 -15
  221. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +5 -5
  222. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +2 -0
  223. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +30 -141
  224. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +233 -112
  225. data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +10 -2
  226. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +2 -2
  227. data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +16 -6
  228. data/lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json +60 -61
  229. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +30 -30
  230. data/lib/openstudio-standards/standards/necb/common/btap_analysis.rb +79 -0
  231. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +16 -4
  232. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +65 -42
  233. data/lib/openstudio-standards/thermal_zone/{thermal_zone.rb → information.rb} +12 -45
  234. data/lib/openstudio-standards/thermal_zone/thermostat_schedules.rb +152 -0
  235. data/lib/openstudio-standards/version.rb +1 -1
  236. data/lib/openstudio-standards/weather/stat_file.rb +2 -2
  237. data/lib/openstudio-standards.rb +55 -38
  238. metadata +106 -66
  239. data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +0 -61
  240. data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +0 -1904
  241. data/lib/openstudio-standards/hvac/components/create.rb +0 -169
  242. data/lib/openstudio-standards/hvac/components/modify.rb +0 -42
  243. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +0 -438
  244. data/lib/openstudio-standards/prototypes/common/objects/Prototype.BoilerHotWater.rb +0 -123
  245. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CentralAirSourceHeatPump.rb +0 -216
  246. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXSingleSpeed.rb +0 -273
  247. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +0 -159
  248. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWater.rb +0 -77
  249. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +0 -154
  250. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +0 -214
  251. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingElectric.rb +0 -53
  252. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +0 -72
  253. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWater.rb +0 -95
  254. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +0 -125
  255. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +0 -17
  256. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.transformers.rb +0 -90
  257. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Pump.rb +0 -4
  258. data/lib/openstudio-standards/prototypes/common/objects/Prototype.PumpVariableSpeed.rb +0 -70
  259. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +0 -590
  260. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +0 -901
  261. data/lib/openstudio-standards/standards/Standards.FanConstantVolume.rb +0 -5
  262. data/lib/openstudio-standards/standards/Standards.FanOnOff.rb +0 -5
  263. data/lib/openstudio-standards/standards/Standards.FanZoneExhaust.rb +0 -5
  264. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsConstantSpeed.rb +0 -5
  265. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +0 -55
  266. data/lib/openstudio-standards/standards/Standards.PumpConstantSpeed.rb +0 -5
  267. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +0 -5
  268. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +0 -5
  269. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanZoneExhaust.rb +0 -5
  270. data/lib/openstudio-standards/standards/cbes/data/cbes.fans.json +0 -328
  271. data/lib/openstudio-standards/standards/deer/data/deer.fans.json +0 -328
  272. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/ConstructionProperties.csv +0 -0
  273. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/Constructions.csv +0 -0
  274. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/construction_sets.csv +0 -0
  275. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/constructions_opaque.csv +0 -0
  276. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/costs_local_factors.csv +0 -0
  277. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/hvac_vent_ahu.csv +0 -0
  278. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/lighting_sets.csv +0 -0
  279. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/locations.csv +0 -0
  280. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_glazing.csv +0 -0
  281. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_lighting.csv +0 -0
  282. /data/lib/openstudio-standards/btap/{costing/common_resources → common_resources}/materials_opaque.csv +0 -0
  283. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb +0 -0
  284. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.PumpVariableSpeed.rb +0 -0
  285. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.PumpVariableSpeed.rb +0 -0
  286. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.PumpVariableSpeed.rb +0 -0
  287. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.PumpVariableSpeed.rb +0 -0
  288. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump.rb +0 -0
  289. /data/lib/openstudio-standards/{prototypes → standards}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed.rb +0 -0
@@ -105,8 +105,8 @@ Standard.class_eval do
105
105
  model_update_exhaust_fan_efficiency(model)
106
106
  model_update_fan_efficiency(model)
107
107
  # rename air loop and plant loop nodes for readability
108
- rename_air_loop_nodes(model)
109
- rename_plant_loop_nodes(model)
108
+ OpenstudioStandards::HVAC.rename_air_loop_nodes(model)
109
+ OpenstudioStandards::HVAC.rename_plant_loop_nodes(model)
110
110
  # remove unused objects
111
111
  model_remove_unused_resource_objects(model)
112
112
  # Add output variables for debugging
@@ -118,6 +118,28 @@ Standard.class_eval do
118
118
  return measure_model
119
119
  end
120
120
 
121
+ # Loads a JSON file containing the space type map into a hash
122
+ #
123
+ # @param hvac_map_file [String] path to JSON file, relative to the /data folder
124
+ # @return [Hash] returns a hash that contains the space type map
125
+ def load_hvac_map(hvac_map_file)
126
+ # Load the geometry .osm from relative to the data folder
127
+ rel_path_to_hvac_map = "../../../../../data/#{hvac_map_file}"
128
+
129
+ # Load the JSON depending on whether running from normal gem location
130
+ # or from the embedded location in the OpenStudio CLI
131
+ if File.dirname(__FILE__)[0] == ':'
132
+ # running from embedded location in OpenStudio CLI
133
+ hvac_map_string = load_resource_relative(rel_path_to_hvac_map)
134
+ hvac_map = JSON.parse(hvac_map_string)
135
+ else
136
+ abs_path = File.join(File.dirname(__FILE__), rel_path_to_hvac_map)
137
+ hvac_map = JSON.parse(File.read(abs_path)) if File.exist?(abs_path)
138
+ end
139
+
140
+ return hvac_map
141
+ end
142
+
121
143
  # Replaces the contents of 'model_to_replace' with the contents of 'new_model.'
122
144
  # This method can be used when the memory location of model_to_replace needs
123
145
  # to be preserved, for example, when a measure is passed.
@@ -183,6 +205,105 @@ Standard.class_eval do
183
205
  return true
184
206
  end
185
207
 
208
+
209
+ # load a model into OS & version translates, exiting and erroring if a problem is found
210
+ #
211
+ # @param model_path_string [String] file path to OpenStudio model file
212
+ # @return [OpenStudio::Model::Model] OpenStudio model object
213
+ def safe_load_model(model_path_string)
214
+ model_path = OpenStudio::Path.new(model_path_string)
215
+ if OpenStudio.exists(model_path)
216
+ version_translator = OpenStudio::OSVersion::VersionTranslator.new
217
+ model = version_translator.loadModel(model_path)
218
+ if model.empty?
219
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', "Version translation failed for #{model_path_string}")
220
+ return false
221
+ else
222
+ model = model.get
223
+ end
224
+ else
225
+ OpenStudio.logFree(OpenStudio::Error, 'openstudio.model.Model', "#{model_path_string} couldn't be found")
226
+ return false
227
+ end
228
+ return model
229
+ end
230
+
231
+ # Remove all resource objects in the model
232
+ #
233
+ # @param model [OpenStudio::Model::Model] OpenStudio model object
234
+ # @return [OpenStudio::Model::Model] OpenStudio model object
235
+ def strip_model(model)
236
+ # remove all materials
237
+ model.getMaterials.each(&:remove)
238
+
239
+ # remove all constructions
240
+ model.getConstructions.each(&:remove)
241
+
242
+ # remove performance curves
243
+ model.getCurves.each do |curve|
244
+ model.removeObject(curve.handle)
245
+ end
246
+
247
+ # remove all zone equipment
248
+ model.getThermalZones.sort.each do |zone|
249
+ zone.equipment.each(&:remove)
250
+ end
251
+
252
+ # remove all thermostats
253
+ model.getThermostatSetpointDualSetpoints.each(&:remove)
254
+
255
+ # remove all people
256
+ model.getPeoples.each(&:remove)
257
+ model.getPeopleDefinitions.each(&:remove)
258
+
259
+ # remove all lights
260
+ model.getLightss.each(&:remove)
261
+ model.getLightsDefinitions.each(&:remove)
262
+
263
+ # remove all electric equipment
264
+ model.getElectricEquipments.each(&:remove)
265
+ model.getElectricEquipmentDefinitions.each(&:remove)
266
+
267
+ # remove all gas equipment
268
+ model.getGasEquipments.each(&:remove)
269
+ model.getGasEquipmentDefinitions.each(&:remove)
270
+
271
+ # remove all outdoor air
272
+ model.getDesignSpecificationOutdoorAirs.each(&:remove)
273
+
274
+ # remove all infiltration
275
+ model.getSpaceInfiltrationDesignFlowRates.each(&:remove)
276
+
277
+ # Remove all internal mass
278
+ model.getInternalMasss.each(&:remove)
279
+
280
+ # Remove all internal mass defs
281
+ model.getInternalMassDefinitions.each(&:remove)
282
+
283
+ # Remove all thermal zones
284
+ model.getThermalZones.each(&:remove)
285
+
286
+ # Remove all schedules
287
+ model.getSchedules.each(&:remove)
288
+
289
+ # Remove all schedule type limits
290
+ model.getScheduleTypeLimitss.each(&:remove)
291
+
292
+ # Remove the sizing parameters
293
+ model.getSizingParameters.remove
294
+
295
+ # Remove the design days
296
+ model.getDesignDays.each(&:remove)
297
+
298
+ # Remove the rendering colors
299
+ model.getRenderingColors.each(&:remove)
300
+
301
+ # Remove the daylight controls
302
+ model.getDaylightingControls.each(&:remove)
303
+
304
+ return model
305
+ end
306
+
186
307
  # Read the space type to space map from the model
187
308
  # instead of relying on an externally-defined mapping.
188
309
  def get_space_type_maps_from_model(model)
@@ -242,10 +363,13 @@ Standard.class_eval do
242
363
  space_type_apply_rendering_color(space_type)
243
364
 
244
365
  # Loads
245
- space_type_apply_internal_loads(space_type, true, true, true, true, true)
366
+ space_type_apply_internal_loads(space_type)
246
367
 
247
368
  # Schedules
248
- space_type_apply_internal_load_schedules(space_type, true, true, true, true, true, true)
369
+ space_type_apply_internal_load_schedules(space_type)
370
+
371
+ # Thermostat Schedules
372
+ space_type_apply_thermostat_schedules(space_type)
249
373
  end
250
374
 
251
375
  OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Finished applying space types (loads)')
@@ -1421,18 +1545,9 @@ Standard.class_eval do
1421
1545
  model.getFanOnOffs.sort.each { |obj| prototype_fan_apply_prototype_fan_efficiency(obj) }
1422
1546
  model.getFanZoneExhausts.sort.each { |obj| prototype_fan_apply_prototype_fan_efficiency(obj) }
1423
1547
 
1424
- # Gas Heating Coil
1425
- model.getCoilHeatingGass.sort.each { |obj| coil_heating_gas_apply_prototype_efficiency(obj) }
1426
-
1427
1548
  # Add Economizers
1428
1549
  apply_economizers(climate_zone, model)
1429
1550
 
1430
- # @todo What is the logic behind hard-sizing hot water coil convergence tolerances?
1431
- model.getControllerWaterCoils.sort.each { |obj| controller_water_coil_set_convergence_limits(obj) }
1432
-
1433
- # Adjust defrost curve limits for coil heating dx single speed
1434
- model.getCoilHeatingDXSingleSpeeds.sort.each { |obj| coil_heating_dx_single_speed_apply_defrost_eir_curve_limits(obj) }
1435
-
1436
1551
  # Pump part load performances
1437
1552
  model.getPumpVariableSpeeds.sort.each { |obj| pump_variable_speed_control_type(obj) }
1438
1553