urbanopt-cli 0.10.0 → 0.11.0

Sign up to get free protection for your applications and to get access to all the features.
Files changed (712) hide show
  1. checksums.yaml +4 -4
  2. data/.github/release.yml +24 -0
  3. data/.github/workflows/nightly_ci_build.yml +39 -29
  4. data/.gitignore +1 -0
  5. data/CHANGELOG.md +17 -0
  6. data/CMakeLists.txt +7 -7
  7. data/FindOpenStudioSDK.cmake +8 -8
  8. data/LICENSE.md +8 -35
  9. data/README.md +25 -10
  10. data/example_files/Gemfile +9 -9
  11. data/example_files/example_project_combined.json +6 -2
  12. data/example_files/example_project_with_ghe.json +859 -0
  13. data/example_files/mappers/Baseline.rb +39 -415
  14. data/example_files/mappers/ChilledWaterStorage.rb +1 -1
  15. data/example_files/mappers/CreateBar.rb +1 -1
  16. data/example_files/mappers/EvCharging.rb +1 -1
  17. data/example_files/mappers/FlexibleHotWater.rb +1 -1
  18. data/example_files/mappers/Floorspace.rb +1 -1
  19. data/example_files/mappers/HighEfficiency.rb +1 -1
  20. data/example_files/mappers/HighEfficiencyCreateBar.rb +1 -1
  21. data/example_files/mappers/HighEfficiencyFloorspace.rb +1 -1
  22. data/example_files/mappers/PeakHoursMelsShedding.rb +1 -1
  23. data/example_files/mappers/PeakHoursThermostatAdjust.rb +1 -1
  24. data/example_files/mappers/ThermalStorage.rb +1 -1
  25. data/example_files/mappers/base_workflow.osw +11 -4
  26. data/example_files/mappers/residential/template/util.rb +138 -0
  27. data/example_files/mappers/residential/util.rb +276 -0
  28. data/example_files/measures/BuildResidentialModel/measure.rb +118 -230
  29. data/example_files/measures/BuildResidentialModel/measure.xml +344 -233
  30. data/example_files/measures/BuildResidentialModel/resources/geometry.rb +7 -2
  31. data/example_files/measures/BuildResidentialModel/resources/unit_conversions.rb +5 -0
  32. data/example_files/measures/BuildResidentialModel/resources/util.rb +5 -0
  33. data/example_files/measures/BuildResidentialModel/tests/test_build_residential_model.rb +344 -0
  34. data/example_files/measures/BuildResidentialModel/tests/xml_building/17/feature1.xml +2112 -0
  35. data/example_files/measures/BuildResidentialModel/tests/xml_building/17/feature2.xml +2112 -0
  36. data/example_files/osm_building/7.osm +0 -2
  37. data/example_files/osm_building/8.osm +0 -2
  38. data/example_files/osm_building/9.osm +0 -2
  39. data/example_files/python_deps/dependencies.json +4 -3
  40. data/example_files/resources/hpxml-measures/.gitattributes +3 -0
  41. data/example_files/resources/hpxml-measures/.github/pull_request_template.md +2 -2
  42. data/example_files/resources/hpxml-measures/.github/workflows/add_to_project.yml +17 -0
  43. data/example_files/resources/hpxml-measures/.github/workflows/config.yml +37 -8
  44. data/example_files/resources/hpxml-measures/.gitignore +1 -0
  45. data/example_files/resources/hpxml-measures/.readthedocs.yml +6 -2
  46. data/example_files/resources/hpxml-measures/BuildResidentialHPXML/README.md +5596 -0
  47. data/example_files/resources/hpxml-measures/BuildResidentialHPXML/README.md.erb +41 -0
  48. data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.rb +1324 -1035
  49. data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.xml +325 -236
  50. data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/geometry.rb +119 -152
  51. data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{build_residential_hpxml_test.rb → test_build_residential_hpxml.rb} +225 -107
  52. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/README.md +96 -0
  53. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/README.md.erb +41 -0
  54. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/measure.rb +73 -31
  55. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/measure.xml +60 -40
  56. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/README.md +48 -23
  57. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/constants.rb +5 -0
  58. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/schedules.rb +6 -12
  59. data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/tests/{build_residential_schedule_file_test.rb → test_build_residential_schedule_file.rb} +162 -35
  60. data/example_files/resources/hpxml-measures/Changelog.md +57 -1
  61. data/example_files/resources/hpxml-measures/Gemfile +1 -1
  62. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/README.md +83 -0
  63. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/README.md.erb +41 -0
  64. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.rb +1081 -878
  65. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.xml +258 -204
  66. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/airflow.rb +205 -178
  67. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/battery.rb +43 -18
  68. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constants.rb +37 -112
  69. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constructions.rb +34 -73
  70. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/data/Xing_okstate_0664D_13659_Table_A-3.csv +4165 -0
  71. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/data/unavailable_periods.csv +2 -2
  72. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/energyplus.rb +5 -1
  73. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/generator.rb +13 -7
  74. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/geometry.rb +95 -42
  75. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hotwater_appliances.rb +132 -108
  76. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml.rb +1695 -1267
  77. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_defaults.rb +668 -589
  78. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schema/HPXML.xsd +304 -553
  79. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.xml +197 -112
  80. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac.rb +1140 -1745
  81. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac_sizing.rb +412 -325
  82. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/lighting.rb +56 -48
  83. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/location.rb +49 -38
  84. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/materials.rb +5 -0
  85. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure.rb +17 -1
  86. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/minitest_helper.rb +5 -0
  87. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/misc_loads.rb +94 -78
  88. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/output.rb +60 -2
  89. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/psychrometrics.rb +6 -1
  90. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/pv.rb +11 -5
  91. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-non-stochastic.csv +1 -1
  92. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic-30-mins.csv +52561 -0
  93. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_2.csv +8761 -0
  94. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_3.csv +8761 -0
  95. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_4.csv +8761 -0
  96. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_5.csv +8761 -0
  97. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_6.csv +8761 -0
  98. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedules.rb +129 -137
  99. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/simcontrols.rb +12 -21
  100. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/unit_conversions.rb +5 -0
  101. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/util.rb +7 -2
  102. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/utility_bills.rb +6 -1
  103. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/version.rb +7 -2
  104. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/waterheater.rb +179 -144
  105. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/weather.rb +129 -71
  106. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlhelper.rb +5 -0
  107. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlvalidator.rb +23 -6
  108. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_airflow.rb +129 -118
  109. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_battery.rb +25 -20
  110. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_defaults.rb +2282 -2239
  111. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_enclosure.rb +395 -204
  112. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_generator.rb +12 -7
  113. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb +56 -51
  114. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac.rb +369 -230
  115. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac_sizing.rb +371 -191
  116. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_lighting.rb +27 -20
  117. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_location.rb +55 -5
  118. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_miscloads.rb +35 -30
  119. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_pv.rb +13 -8
  120. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_schedules.rb +107 -93
  121. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_simcontrols.rb +11 -6
  122. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_validation.rb +757 -573
  123. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_water_heater.rb +77 -72
  124. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_weather.rb +36 -6
  125. data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/util.rb +5 -0
  126. data/example_files/resources/hpxml-measures/README.md +2 -0
  127. data/example_files/resources/hpxml-measures/Rakefile +10 -3
  128. data/example_files/resources/hpxml-measures/ReportSimulationOutput/README.md +787 -0
  129. data/example_files/resources/hpxml-measures/ReportSimulationOutput/README.md.erb +41 -0
  130. data/example_files/resources/hpxml-measures/ReportSimulationOutput/measure.rb +730 -418
  131. data/example_files/resources/hpxml-measures/ReportSimulationOutput/measure.xml +1215 -9
  132. data/example_files/resources/hpxml-measures/ReportSimulationOutput/tests/{output_report_test.rb → test_report_sim_output.rb} +130 -299
  133. data/example_files/resources/hpxml-measures/ReportUtilityBills/README.md +87 -0
  134. data/example_files/resources/hpxml-measures/ReportUtilityBills/README.md.erb +41 -0
  135. data/example_files/resources/hpxml-measures/ReportUtilityBills/measure.rb +261 -89
  136. data/example_files/resources/hpxml-measures/ReportUtilityBills/measure.xml +179 -94
  137. data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/Average_retail_price_of_electricity.csv +68 -68
  138. data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/NG_PRI_SUM_A_EPG0_PRS_DMCF_A.csv +3 -2
  139. data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/PET_PRI_WFR_A_EPD2F_PRS_DPGAL_W.csv +713 -685
  140. data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/PET_PRI_WFR_A_EPLLPA_PRS_DPGAL_W.csv +716 -688
  141. data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/README.md +5 -2
  142. data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/util.rb +18 -9
  143. data/example_files/resources/hpxml-measures/ReportUtilityBills/tests/test_report_utility_bills.rb +1308 -0
  144. data/example_files/resources/hpxml-measures/docs/requirements.txt +5 -0
  145. data/example_files/resources/hpxml-measures/docs/source/conf.py +1 -2
  146. data/example_files/resources/hpxml-measures/docs/source/intro.rst +3 -20
  147. data/example_files/resources/hpxml-measures/docs/source/usage_instructions.rst +1 -1
  148. data/example_files/resources/hpxml-measures/docs/source/workflow_inputs.rst +917 -564
  149. data/example_files/resources/hpxml-measures/docs/source/workflow_outputs.rst +79 -42
  150. data/example_files/resources/hpxml-measures/tasks.rb +2305 -2055
  151. data/example_files/resources/hpxml-measures/workflow/hpxml_inputs.json +270 -587
  152. data/example_files/resources/hpxml-measures/workflow/real_homes/house001.xml +559 -557
  153. data/example_files/resources/hpxml-measures/workflow/real_homes/house002.xml +522 -520
  154. data/example_files/resources/hpxml-measures/workflow/real_homes/house003.xml +534 -532
  155. data/example_files/resources/hpxml-measures/workflow/real_homes/house004.xml +547 -545
  156. data/example_files/resources/hpxml-measures/workflow/real_homes/house005.xml +546 -544
  157. data/example_files/resources/hpxml-measures/workflow/real_homes/house006.xml +603 -623
  158. data/example_files/resources/hpxml-measures/workflow/real_homes/house007.xml +613 -633
  159. data/example_files/resources/hpxml-measures/workflow/real_homes/house008.xml +699 -721
  160. data/example_files/resources/hpxml-measures/workflow/real_homes/house009.xml +662 -661
  161. data/example_files/resources/hpxml-measures/workflow/real_homes/house010.xml +657 -677
  162. data/example_files/resources/hpxml-measures/workflow/real_homes/house011.xml +470 -467
  163. data/example_files/resources/hpxml-measures/workflow/real_homes/house012.xml +441 -438
  164. data/example_files/resources/hpxml-measures/workflow/real_homes/house013.xml +468 -465
  165. data/example_files/resources/hpxml-measures/workflow/real_homes/house014.xml +469 -466
  166. data/example_files/resources/hpxml-measures/workflow/real_homes/house015.xml +468 -465
  167. data/example_files/resources/hpxml-measures/workflow/real_homes/house016.xml +717 -714
  168. data/example_files/resources/hpxml-measures/workflow/real_homes/house017.xml +647 -645
  169. data/example_files/resources/hpxml-measures/workflow/real_homes/house018.xml +569 -566
  170. data/example_files/resources/hpxml-measures/workflow/real_homes/house019.xml +602 -599
  171. data/example_files/resources/hpxml-measures/workflow/real_homes/house020.xml +630 -627
  172. data/example_files/resources/hpxml-measures/workflow/real_homes/house021.xml +776 -774
  173. data/example_files/resources/hpxml-measures/workflow/real_homes/house022.xml +670 -667
  174. data/example_files/resources/hpxml-measures/workflow/real_homes/house023.xml +632 -629
  175. data/example_files/resources/hpxml-measures/workflow/real_homes/house024.xml +731 -729
  176. data/example_files/resources/hpxml-measures/workflow/real_homes/house025.xml +672 -669
  177. data/example_files/resources/hpxml-measures/workflow/real_homes/house026.xml +667 -644
  178. data/example_files/resources/hpxml-measures/workflow/real_homes/house027.xml +646 -644
  179. data/example_files/resources/hpxml-measures/workflow/real_homes/house028.xml +690 -688
  180. data/example_files/resources/hpxml-measures/workflow/real_homes/house029.xml +701 -699
  181. data/example_files/resources/hpxml-measures/workflow/real_homes/house030.xml +637 -615
  182. data/example_files/resources/hpxml-measures/workflow/real_homes/house031.xml +690 -688
  183. data/example_files/resources/hpxml-measures/workflow/real_homes/house032.xml +557 -554
  184. data/example_files/resources/hpxml-measures/workflow/real_homes/house033.xml +534 -531
  185. data/example_files/resources/hpxml-measures/workflow/real_homes/house034.xml +636 -635
  186. data/example_files/resources/hpxml-measures/workflow/real_homes/house035.xml +616 -613
  187. data/example_files/resources/hpxml-measures/workflow/real_homes/house036.xml +601 -598
  188. data/example_files/resources/hpxml-measures/workflow/real_homes/house037.xml +581 -578
  189. data/example_files/resources/hpxml-measures/workflow/real_homes/house038.xml +624 -622
  190. data/example_files/resources/hpxml-measures/workflow/real_homes/house039.xml +584 -582
  191. data/example_files/resources/hpxml-measures/workflow/real_homes/house040.xml +631 -629
  192. data/example_files/resources/hpxml-measures/workflow/real_homes/house041.xml +922 -921
  193. data/example_files/resources/hpxml-measures/workflow/real_homes/house042.xml +855 -853
  194. data/example_files/resources/hpxml-measures/workflow/real_homes/house043.xml +739 -737
  195. data/example_files/resources/hpxml-measures/workflow/real_homes/house044.xml +798 -796
  196. data/example_files/resources/hpxml-measures/workflow/real_homes/house045.xml +696 -694
  197. data/example_files/resources/hpxml-measures/workflow/real_homes/house046.xml +487 -483
  198. data/example_files/resources/hpxml-measures/workflow/real_homes/house047.xml +443 -440
  199. data/example_files/resources/hpxml-measures/workflow/real_homes/house048.xml +688 -686
  200. data/example_files/resources/hpxml-measures/workflow/real_homes/house049.xml +722 -720
  201. data/example_files/resources/hpxml-measures/workflow/real_homes/house050.xml +619 -617
  202. data/example_files/resources/hpxml-measures/workflow/run_simulation.rb +13 -20
  203. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-coal.xml +9 -9
  204. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-portable.xml +11 -12
  205. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-whole-home.xml +11 -12
  206. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-multiple.xml +12 -13
  207. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier.xml +11 -12
  208. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-gas.xml +9 -9
  209. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-modified.xml +9 -9
  210. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-none.xml +4 -4
  211. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil.xml +9 -9
  212. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane.xml +9 -9
  213. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-wood.xml +9 -9
  214. data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-cathedral.xml +11 -11
  215. data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-conditioned.xml +10 -10
  216. data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-flat.xml +9 -9
  217. data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-radiant-barrier.xml +10 -11
  218. data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-unvented-insulated-roof.xml +9 -9
  219. data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-vented.xml +8 -8
  220. data/example_files/resources/hpxml-measures/workflow/sample_files/base-battery-scheduled.xml +571 -569
  221. data/example_files/resources/hpxml-measures/workflow/sample_files/base-battery.xml +9 -9
  222. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-multifamily-buffer-space.xml → base-bldgtype-mf-unit-adjacent-to-multifamily-buffer-space.xml} +5 -5
  223. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-multiple.xml → base-bldgtype-mf-unit-adjacent-to-multiple.xml} +17 -17
  224. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-non-freezing-space.xml → base-bldgtype-mf-unit-adjacent-to-non-freezing-space.xml} +5 -5
  225. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-other-heated-space.xml → base-bldgtype-mf-unit-adjacent-to-other-heated-space.xml} +5 -5
  226. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-other-housing-unit.xml → base-bldgtype-mf-unit-adjacent-to-other-housing-unit.xml} +5 -5
  227. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-infil-compartmentalization-test.xml → base-bldgtype-mf-unit-infil-compartmentalization-test.xml} +461 -461
  228. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-residents-1.xml → base-bldgtype-mf-unit-residents-1.xml} +453 -453
  229. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-baseboard.xml → base-bldgtype-mf-unit-shared-boiler-chiller-baseboard.xml} +11 -11
  230. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-fan-coil-ducted.xml → base-bldgtype-mf-unit-shared-boiler-chiller-fan-coil-ducted.xml} +11 -11
  231. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-fan-coil.xml → base-bldgtype-mf-unit-shared-boiler-chiller-fan-coil.xml} +11 -11
  232. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-boiler-chiller-water-loop-heat-pump.xml} +11 -11
  233. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-cooling-tower-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-boiler-cooling-tower-water-loop-heat-pump.xml} +11 -11
  234. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-baseboard.xml → base-bldgtype-mf-unit-shared-boiler-only-baseboard.xml} +11 -11
  235. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-fan-coil-ducted.xml → base-bldgtype-mf-unit-shared-boiler-only-fan-coil-ducted.xml} +11 -11
  236. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-fan-coil-eae.xml → base-bldgtype-mf-unit-shared-boiler-only-fan-coil-eae.xml} +11 -11
  237. data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-mf-unit-shared-boiler-only-fan-coil-fireplace-elec.xml +433 -0
  238. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml → base-bldgtype-mf-unit-shared-boiler-only-fan-coil.xml} +11 -11
  239. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-boiler-only-water-loop-heat-pump.xml} +11 -11
  240. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-baseboard.xml → base-bldgtype-mf-unit-shared-chiller-only-baseboard.xml} +11 -11
  241. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-fan-coil-ducted.xml → base-bldgtype-mf-unit-shared-chiller-only-fan-coil-ducted.xml} +11 -11
  242. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml → base-bldgtype-mf-unit-shared-chiller-only-fan-coil.xml} +11 -11
  243. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-chiller-only-water-loop-heat-pump.xml} +11 -11
  244. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-cooling-tower-only-water-loop-heat-pump.xml} +11 -11
  245. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-generator.xml → base-bldgtype-mf-unit-shared-generator.xml} +13 -13
  246. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml → base-bldgtype-mf-unit-shared-ground-loop-ground-to-air-heat-pump.xml} +13 -13
  247. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-laundry-room-multiple-water-heaters.xml → base-bldgtype-mf-unit-shared-laundry-room-multiple-water-heaters.xml} +480 -480
  248. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-laundry-room.xml → base-bldgtype-mf-unit-shared-laundry-room.xml} +10 -10
  249. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-mechvent-multiple.xml → base-bldgtype-mf-unit-shared-mechvent-multiple.xml} +15 -15
  250. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-mechvent-preconditioning.xml → base-bldgtype-mf-unit-shared-mechvent-preconditioning.xml} +13 -13
  251. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-mechvent.xml → base-bldgtype-mf-unit-shared-mechvent.xml} +13 -13
  252. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-pv.xml → base-bldgtype-mf-unit-shared-pv.xml} +13 -13
  253. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-water-heater-recirc.xml → base-bldgtype-mf-unit-shared-water-heater-recirc.xml} +13 -13
  254. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-water-heater.xml → base-bldgtype-mf-unit-shared-water-heater.xml} +13 -13
  255. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily.xml → base-bldgtype-mf-unit.xml} +13 -13
  256. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached-2stories.xml → base-bldgtype-sfa-unit-2stories.xml} +610 -610
  257. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached-atticroof-cathedral.xml → base-bldgtype-sfa-unit-atticroof-cathedral.xml} +558 -558
  258. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached-infil-compartmentalization-test.xml → base-bldgtype-sfa-unit-infil-compartmentalization-test.xml} +610 -610
  259. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached.xml → base-bldgtype-sfa-unit.xml} +610 -610
  260. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless-outside.xml +8 -8
  261. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless.xml +9 -9
  262. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-2-speed.xml +9 -9
  263. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-gshp.xml +9 -9
  264. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-hpwh.xml +9 -9
  265. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-tankless.xml +9 -9
  266. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-var-speed.xml +9 -9
  267. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater.xml +9 -9
  268. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-dwhr.xml +9 -9
  269. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-detailed-setpoints.xml +507 -505
  270. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-dse.xml +9 -9
  271. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-outside.xml +8 -8
  272. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-standbyloss.xml +9 -9
  273. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-with-solar-fraction.xml +9 -9
  274. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect.xml +9 -9
  275. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-electric.xml +9 -9
  276. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-gas.xml +9 -9
  277. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-hpwh.xml +9 -9
  278. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-indirect.xml +9 -9
  279. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-low-flow-fixtures.xml +12 -10
  280. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-multiple.xml +14 -14
  281. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-none.xml +5 -5
  282. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-demand.xml +9 -9
  283. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-manual.xml +9 -9
  284. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-nocontrol.xml +9 -9
  285. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-temperature.xml +9 -9
  286. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-timer.xml +9 -9
  287. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-evacuated-tube.xml +9 -9
  288. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-flat-plate.xml +9 -9
  289. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-ics.xml +9 -9
  290. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-fraction.xml +9 -9
  291. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-indirect-flat-plate.xml +9 -9
  292. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-thermosyphon-flat-plate.xml +9 -9
  293. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-coal.xml +9 -9
  294. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-detailed-setpoints.xml +12 -10
  295. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-elec-uef.xml +9 -9
  296. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-outside.xml +8 -8
  297. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef-fhr.xml +9 -9
  298. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef.xml +9 -9
  299. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas.xml +9 -9
  300. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-detailed-schedules.xml +13 -11
  301. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-operating-mode-heat-pump-only.xml +9 -9
  302. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-outside.xml +8 -8
  303. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-uef.xml +9 -9
  304. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar-fraction.xml +9 -9
  305. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar.xml +9 -9
  306. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump.xml +9 -9
  307. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-model-type-stratified-detailed-occupancy-stochastic.xml +12 -10
  308. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-model-type-stratified.xml +9 -9
  309. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-oil.xml +9 -9
  310. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-wood.xml +9 -9
  311. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-detailed-setpoints.xml +12 -10
  312. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-outside.xml +8 -8
  313. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-uef.xml +9 -9
  314. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric.xml +9 -9
  315. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-uef.xml +9 -9
  316. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar-fraction.xml +9 -9
  317. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar.xml +9 -9
  318. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas.xml +9 -9
  319. data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-propane.xml +9 -9
  320. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories-garage.xml +13 -14
  321. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories.xml +11 -11
  322. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-1.xml +9 -9
  323. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-2.xml +9 -9
  324. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-4.xml +9 -9
  325. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-5.xml +9 -9
  326. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-ceilingtypes.xml +576 -576
  327. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-floortypes.xml +519 -519
  328. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-garage.xml +4 -5
  329. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ach-house-pressure.xml +9 -9
  330. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm-house-pressure.xml +9 -9
  331. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm50.xml +9 -9
  332. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ela.xml +548 -548
  333. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-flue.xml +9 -9
  334. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-ach.xml +9 -9
  335. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-cfm.xml +551 -551
  336. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-orientations.xml +9 -9
  337. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-overhangs.xml +9 -9
  338. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-rooftypes.xml +9 -9
  339. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-physical-properties.xml +9 -9
  340. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-shading.xml +9 -9
  341. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-storms.xml +9 -9
  342. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights.xml +9 -9
  343. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-level.xml +10 -11
  344. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-thermal-mass.xml +9 -9
  345. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-walltypes.xml +19 -19
  346. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-natural-ventilation-availability.xml +555 -553
  347. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-none.xml +9 -9
  348. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-physical-properties.xml +9 -9
  349. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-shading-seasons.xml +560 -558
  350. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-shading.xml +9 -9
  351. data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-storms.xml +9 -9
  352. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-ambient.xml +10 -10
  353. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-basement-garage.xml +10 -11
  354. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-belly-wing-no-skirt.xml +496 -0
  355. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-belly-wing-skirt.xml +496 -0
  356. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-complex.xml +18 -18
  357. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-schedules-simple-power-outage-natvent-unavailable.xml → base-foundation-conditioned-basement-slab-insulation-full.xml} +552 -564
  358. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-slab-insulation.xml +9 -9
  359. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-wall-insulation.xml +555 -555
  360. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-crawlspace.xml +8 -8
  361. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-multiple.xml +5 -5
  362. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-slab.xml +10 -11
  363. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-above-grade.xml +4 -4
  364. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-assembly-r.xml +4 -4
  365. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-wall-insulation.xml +4 -4
  366. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement.xml +4 -4
  367. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unvented-crawlspace.xml +9 -9
  368. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace-above-grade.xml +558 -0
  369. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace.xml +9 -9
  370. data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-walkout-basement.xml +15 -15
  371. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml +9 -9
  372. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-heating-capacity-17f.xml +552 -552
  373. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml +9 -9
  374. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-lockout-temperatures.xml +562 -562
  375. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-seer2-hspf2.xml +557 -557
  376. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed.xml +9 -9
  377. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-2-speed.xml +9 -9
  378. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler-hvac-seasons.xml +586 -586
  379. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler-switchover-temperature.xml +9 -9
  380. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler.xml +9 -9
  381. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-furnace.xml +9 -9
  382. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-acca.xml → base-hvac-air-to-air-heat-pump-var-speed-detailed-performance-other-temperatures.xml} +89 -13
  383. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-hers.xml → base-hvac-air-to-air-heat-pump-var-speed-detailed-performance.xml} +107 -13
  384. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed.xml +9 -9
  385. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-sizing-controls.xml +567 -565
  386. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize.xml +9 -9
  387. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-coal-only.xml +9 -9
  388. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-elec-only.xml +9 -9
  389. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-central-ac-1-speed.xml +9 -9
  390. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only-pilot.xml +512 -512
  391. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only.xml +9 -9
  392. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-oil-only.xml +9 -9
  393. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-propane-only.xml +9 -9
  394. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-wood-only.xml +9 -9
  395. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed-seer2.xml +536 -536
  396. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed.xml +9 -9
  397. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-2-speed.xml +9 -9
  398. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-central-ac-only-var-speed.xml → base-hvac-central-ac-only-var-speed-detailed-performance.xml} +49 -10
  399. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-var-speed.xml +9 -9
  400. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml +9 -9
  401. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dse.xml +9 -9
  402. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-lockout-temperatures.xml +559 -559
  403. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml +9 -9
  404. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.xml +9 -9
  405. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.xml +9 -9
  406. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-mini-split-heat-pump-ducted.xml +9 -9
  407. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-area-fractions.xml +11 -12
  408. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-area-multipliers.xml +558 -558
  409. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-buried.xml +554 -554
  410. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-furnace-gas-room-ac.xml → base-hvac-ducts-defaults.xml} +28 -14
  411. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-effective-rvalue.xml +552 -552
  412. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-cfm50.xml +9 -9
  413. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-percent.xml +9 -9
  414. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-elec-resistance-only.xml +9 -9
  415. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-furnace-gas.xml +9 -9
  416. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only-ducted.xml +9 -9
  417. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only.xml +9 -9
  418. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fireplace-wood-only.xml +9 -9
  419. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only.xml +15 -10
  420. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-coal-only.xml +9 -9
  421. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-central-ac-1-speed.xml +9 -9
  422. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-only.xml +9 -9
  423. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-2-speed.xml +9 -9
  424. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-var-speed.xml +9 -9
  425. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only-detailed-setpoints.xml +12 -10
  426. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only-pilot.xml +541 -541
  427. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only.xml +9 -9
  428. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-room-ac.xml +9 -9
  429. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-oil-only.xml +9 -9
  430. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-propane-only.xml +9 -9
  431. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-wood-only.xml +9 -9
  432. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-x3-dse.xml +9 -9
  433. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-cooling-only.xml +9 -9
  434. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-heating-only.xml +9 -9
  435. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump.xml +9 -9
  436. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-1-speed.xml +9 -9
  437. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-2-speed.xml +9 -9
  438. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-air-to-air-heat-pump-1-speed-autosized-backup.xml → base-hvac-install-quality-air-to-air-heat-pump-var-speed-detailed-performance.xml} +650 -556
  439. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-var-speed.xml +9 -9
  440. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-1-speed.xml +9 -9
  441. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-2-speed.xml +9 -9
  442. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-var-speed.xml +9 -9
  443. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-only.xml +9 -9
  444. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-ground-to-air-heat-pump.xml +9 -9
  445. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-mini-split-air-conditioner-only-ducted.xml +9 -9
  446. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-mini-split-heat-pump-ducted.xml +9 -9
  447. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ducted.xml +9 -9
  448. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-mini-split-air-conditioner-only-ducted.xml → base-hvac-mini-split-air-conditioner-only-ductless-detailed-performance.xml} +50 -49
  449. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ductless.xml +9 -9
  450. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-cooling-only.xml +9 -9
  451. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-maxload.xml → base-hvac-mini-split-heat-pump-ducted-detailed-performance.xml} +109 -14
  452. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-heating-only.xml +9 -9
  453. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted.xml +9 -9
  454. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-baseboard.xml +524 -524
  455. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted-backup-hardsized.xml → base-hvac-mini-split-heat-pump-ductless-backup-furnace-ducts-defaults.xml} +560 -552
  456. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-furnace.xml +563 -563
  457. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-stove.xml +9 -9
  458. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted.xml → base-hvac-mini-split-heat-pump-ductless-detailed-performance.xml} +108 -60
  459. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-heating-capacity-17f.xml +505 -505
  460. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless.xml +9 -9
  461. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple.xml +9 -9
  462. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-none.xml +10 -11
  463. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac-with-heating-electricity.xml +9 -9
  464. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac-with-heating-natural-gas.xml +504 -504
  465. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac.xml +9 -9
  466. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-pthp-heating-capacity-17f.xml +512 -512
  467. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-pthp.xml +9 -9
  468. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-33percent.xml +9 -9
  469. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-ceer.xml +9 -9
  470. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-detailed-setpoints.xml +12 -10
  471. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only.xml +9 -9
  472. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-with-heating.xml +504 -504
  473. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-with-reverse-cycle.xml +517 -517
  474. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-seasons.xml +9 -9
  475. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints-daily-schedules.xml +9 -9
  476. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints-daily-setbacks.xml +9 -9
  477. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints.xml +9 -9
  478. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-fixed-heater-gas-only.xml → base-hvac-space-heater-gas-only.xml} +10 -10
  479. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-oil-only.xml +9 -9
  480. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-wood-pellets-only.xml +9 -9
  481. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized.xml +9 -9
  482. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-wall-furnace-elec-only.xml +9 -9
  483. data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-ceiling-fans.xml +9 -9
  484. data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-holiday.xml +9 -9
  485. data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-kwh-per-year.xml +531 -528
  486. data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-mixed.xml +536 -536
  487. data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none-ceiling-fans.xml +515 -515
  488. data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none.xml +9 -9
  489. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-AMY-2012.xml +9 -9
  490. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-baltimore-md.xml +9 -9
  491. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-capetown-zaf.xml +9 -9
  492. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-dallas-tx.xml +10 -11
  493. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-duluth-mn.xml +4 -4
  494. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-helena-mt.xml +9 -9
  495. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-honolulu-hi.xml +10 -11
  496. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-miami-fl.xml +10 -11
  497. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-phoenix-az.xml +10 -11
  498. data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-portland-or.xml +9 -9
  499. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-balanced.xml +9 -9
  500. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-bath-kitchen-fans.xml +9 -9
  501. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-airflow-fraction-zero.xml +9 -9
  502. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-dse.xml +9 -9
  503. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-evap-cooler-only-ducted.xml +9 -9
  504. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-supplemental-fan-exhaust.xml +576 -576
  505. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-supplemental-fan-supply.xml +576 -576
  506. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis.xml +9 -9
  507. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv-atre-asre.xml +9 -9
  508. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv.xml +9 -9
  509. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust-rated-flow-rate.xml +9 -9
  510. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust.xml +9 -9
  511. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv-asre.xml +9 -9
  512. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv.xml +9 -9
  513. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-multiple.xml +9 -9
  514. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-supply.xml +9 -9
  515. data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-whole-house-fan.xml +9 -9
  516. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-additional-properties.xml +21 -19
  517. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv-detailed-only.xml +605 -605
  518. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv-mixed.xml +587 -587
  519. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv.xml +9 -9
  520. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills.xml +9 -9
  521. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-defaults.xml +3 -3
  522. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-emissions.xml +9 -9
  523. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators-battery-scheduled.xml +587 -585
  524. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators-battery.xml +584 -584
  525. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators.xml +9 -9
  526. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-ground-conductivity.xml +555 -555
  527. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon.xml +26 -26
  528. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon2.xml +26 -26
  529. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-none.xml +9 -9
  530. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading-bldgtype-multifamily.xml +508 -508
  531. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading.xml +9 -9
  532. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-shielding-of-home.xml +9 -9
  533. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-schedules-simple-power-outage-natvent-available.xml → base-misc-unit-multiplier.xml} +553 -564
  534. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-usage-multiplier.xml +26 -26
  535. data/example_files/resources/hpxml-measures/workflow/sample_files/base-multiple-mf-units.xml +2755 -0
  536. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-multiple-buildings.xml → base-multiple-sfd-buildings.xml} +31 -22
  537. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-ah.xml +9 -9
  538. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-garage.xml +4 -5
  539. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-round-trip-efficiency.xml +597 -597
  540. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-scheduled.xml +599 -597
  541. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery.xml +9 -9
  542. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators-battery-scheduled.xml +615 -613
  543. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators-battery.xml +612 -612
  544. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators.xml +596 -596
  545. data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv.xml +9 -9
  546. data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-0-runperiod-1-month.xml +559 -559
  547. data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-0.xml +555 -555
  548. data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-1-misc-loads-large-uncommon.xml +616 -616
  549. data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-1-misc-loads-large-uncommon2.xml +616 -616
  550. data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-1.xml +547 -547
  551. data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-5.xml +515 -515
  552. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-all-10-mins.xml +14 -12
  553. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-crankcase-heater-40w.xml → base-schedules-detailed-mixed-timesteps-power-outage.xml} +565 -555
  554. data/example_files/resources/hpxml-measures/workflow/sample_files/{base-schedules-detailed-occupancy-stochastic-vacancy-year-round.xml → base-schedules-detailed-mixed-timesteps.xml} +554 -563
  555. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-10-mins.xml +12 -10
  556. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-power-outage.xml +566 -564
  557. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-vacancy.xml +12 -10
  558. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic.xml +12 -10
  559. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints-daily-schedules.xml +12 -10
  560. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints-daily-setbacks.xml +12 -10
  561. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints.xml +12 -10
  562. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-power-outage.xml +619 -619
  563. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-vacancy.xml +618 -618
  564. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple.xml +9 -9
  565. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-calendar-year-custom.xml +9 -9
  566. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-custom.xml +9 -9
  567. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-disabled.xml +9 -9
  568. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-runperiod-1-month.xml +9 -9
  569. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-temperature-capacitance-multiplier.xml +553 -553
  570. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins-occupancy-stochastic-10-mins.xml +12 -10
  571. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins-occupancy-stochastic-60-mins.xml +12 -10
  572. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins.xml +9 -9
  573. data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-30-mins.xml +552 -552
  574. data/example_files/resources/hpxml-measures/workflow/sample_files/base.xml +9 -9
  575. data/example_files/resources/hpxml-measures/workflow/template-build-and-run-hpxml-with-stochastic-occupancy.osw +2 -0
  576. data/example_files/resources/hpxml-measures/workflow/template-run-hpxml-with-stochastic-occupancy-subset.osw +2 -0
  577. data/example_files/resources/hpxml-measures/workflow/template-run-hpxml-with-stochastic-occupancy.osw +2 -0
  578. data/example_files/resources/hpxml-measures/workflow/template-run-hpxml.osw +4 -1
  579. data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Long_Residence.xml +385 -385
  580. data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Vatilo_Residence.xml +378 -380
  581. data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Victor_Residence.xml +369 -369
  582. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AC.xml +7 -7
  583. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AL.xml +7 -7
  584. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AC.xml +7 -7
  585. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AL.xml +7 -7
  586. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AC.xml +7 -7
  587. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AL.xml +7 -7
  588. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AC.xml +7 -7
  589. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AL.xml +7 -7
  590. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AC.xml +7 -7
  591. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AL.xml +7 -7
  592. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AC.xml +7 -7
  593. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AL.xml +7 -7
  594. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AC.xml +7 -7
  595. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AL.xml +7 -7
  596. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AC.xml +7 -7
  597. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AL.xml +7 -7
  598. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AC.xml +7 -7
  599. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AL.xml +7 -7
  600. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AC.xml +7 -7
  601. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AL.xml +7 -7
  602. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AC.xml +7 -7
  603. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AL.xml +7 -7
  604. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L302XC.xml +7 -8
  605. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L304XC.xml +7 -8
  606. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L322XC.xml +6 -6
  607. data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L324XC.xml +6 -6
  608. data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_sizing.csv +363 -0
  609. data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations1.csv +281 -0
  610. data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations1_bills.csv +281 -0
  611. data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations2.csv +141 -0
  612. data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations2_bills.csv +141 -0
  613. data/example_files/resources/hpxml-measures/workflow/tests/compare.py +12 -6
  614. data/example_files/resources/hpxml-measures/workflow/tests/util.rb +1141 -0
  615. data/example_files/weather/USA_CO_Denver.Intl.AP.725650_TMY3.ddy +536 -0
  616. data/example_files/weather/USA_CO_Denver.Intl.AP.725650_TMY3.epw +8768 -0
  617. data/example_files/weather/USA_CO_Denver.Intl.AP.725650_TMY3.stat +554 -0
  618. data/example_files/weather/USA_FL_MacDill.AFB.747880_TMY3.ddy +536 -0
  619. data/example_files/weather/USA_FL_MacDill.AFB.747880_TMY3.epw +8768 -0
  620. data/example_files/weather/USA_FL_MacDill.AFB.747880_TMY3.stat +553 -0
  621. data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3-cache.csv +35 -0
  622. data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3.ddy +536 -0
  623. data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3.epw +8768 -0
  624. data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3.stat +553 -0
  625. data/example_files/weather/USA_NY_Buffalo-Greater.Buffalo.Intl.AP.725280_TMY3-cache.csv +35 -0
  626. data/example_files/xml_building/17/README.md +4 -2
  627. data/example_files/xml_building/17/feature.xml +2112 -0
  628. data/lib/uo_cli/version.rb +1 -1
  629. data/lib/uo_cli.rb +110 -17
  630. data/uo_cli.gemspec +6 -8
  631. metadata +130 -177
  632. data/Jenkinsfile +0 -10
  633. data/example_files/base_workflow_res.osw +0 -276
  634. data/example_files/resources/hpxml-measures/ReportUtilityBills/tests/utility_bills_test.rb +0 -1226
  635. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil-location-miami-fl.xml +0 -551
  636. data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane-location-portland-or.xml +0 -551
  637. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-cooling-only.xml +0 -544
  638. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-heating-only.xml +0 -550
  639. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-acca.xml +0 -552
  640. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-hers.xml +0 -552
  641. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-maxload-miami-fl.xml +0 -552
  642. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-maxload.xml +0 -552
  643. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-acca.xml +0 -552
  644. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-hers.xml +0 -552
  645. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-maxload.xml +0 -552
  646. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-backup-boiler.xml +0 -569
  647. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-backup-furnace.xml +0 -599
  648. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-maxload.xml +0 -552
  649. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-elec-only.xml +0 -506
  650. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-gas-central-ac-1-speed.xml +0 -560
  651. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-gas-only.xml +0 -507
  652. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-only-1-speed.xml +0 -536
  653. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-only-2-speed.xml +0 -536
  654. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-plus-air-to-air-heat-pump-heating.xml +0 -565
  655. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-acca.xml +0 -553
  656. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-hers.xml +0 -553
  657. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-maxload.xml +0 -553
  658. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-elec-resistance-only.xml +0 -497
  659. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-evap-cooler-furnace-gas.xml +0 -544
  660. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-floor-furnace-propane-only.xml +0 -500
  661. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-elec-only.xml +0 -536
  662. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-central-ac-2-speed.xml +0 -551
  663. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-central-ac-var-speed.xml +0 -551
  664. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-only.xml +0 -536
  665. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-cooling-only.xml +0 -546
  666. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-heating-only.xml +0 -552
  667. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-acca.xml +0 -554
  668. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-hers.xml +0 -554
  669. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-maxload.xml +0 -554
  670. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-cooling-only.xml +0 -543
  671. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-heating-only.xml +0 -549
  672. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-acca.xml +0 -551
  673. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-hers.xml +0 -551
  674. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ductless-backup-baseboard.xml +0 -519
  675. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ductless-backup-stove.xml +0 -522
  676. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ptac-with-heating.xml +0 -503
  677. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ptac.xml +0 -496
  678. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-acca.xml +0 -518
  679. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-hers.xml +0 -518
  680. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-maxload.xml +0 -518
  681. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-only.xml +0 -496
  682. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-heating.xml +0 -503
  683. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-acca.xml +0 -518
  684. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-hers.xml +0 -518
  685. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-maxload.xml +0 -518
  686. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-stove-oil-only.xml +0 -500
  687. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-wall-furnace-elec-only.xml +0 -500
  688. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only-pilot-light.xml +0 -506
  689. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-portable-heater-gas-only.xml +0 -501
  690. data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized-allow-increased-fixed-capacities.xml +0 -556
  691. data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-none.xml +0 -548
  692. data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-vacancy-year-round.xml +0 -619
  693. data/example_files/resources/hpxml-measures/workflow/tests/base_results/results.csv +0 -475
  694. data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_bills.csv +0 -475
  695. data/example_files/resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb +0 -1313
  696. data/example_files/resources/measure-info.json +0 -26
  697. data/example_files/resources/meta_measure.rb +0 -301
  698. data/example_files/xml_building/17/unit 1.xml +0 -580
  699. data/example_files/xml_building/17/unit 2.xml +0 -553
  700. data/example_files/xml_building/17/unit 3.xml +0 -553
  701. data/example_files/xml_building/17/unit 4.xml +0 -580
  702. /data/example_files/{residential → mappers/residential/template/iecc}/clothes_dryer.tsv +0 -0
  703. /data/example_files/{residential → mappers/residential/template/iecc}/clothes_washer.tsv +0 -0
  704. /data/example_files/{residential → mappers/residential/template/iecc}/cooling_system.tsv +0 -0
  705. /data/example_files/{residential → mappers/residential/template/iecc}/dishwasher.tsv +0 -0
  706. /data/example_files/{residential → mappers/residential/template/iecc}/enclosure.tsv +0 -0
  707. /data/example_files/{residential → mappers/residential/template/iecc}/heat_pump.tsv +0 -0
  708. /data/example_files/{residential → mappers/residential/template/iecc}/heating_system.tsv +0 -0
  709. /data/example_files/{residential → mappers/residential/template/iecc}/mechanical_ventilation.tsv +0 -0
  710. /data/example_files/{residential → mappers/residential/template/iecc}/refrigerator.tsv +0 -0
  711. /data/example_files/{residential → mappers/residential/template/iecc}/water_heater.tsv +0 -0
  712. /data/example_files/resources/hpxml-measures/ReportUtilityBills/tests/{JacksonElectricMemberCorp-ResidentialSeniorCitizenLowIncomeAssistance.json → Detailed Rate.json} +0 -0
@@ -1,3 +1,8 @@
1
+ # *********************************************************************************
2
+ # URBANopt (tm), Copyright (c) Alliance for Sustainable Energy, LLC.
3
+ # See also https://github.com/urbanopt/urbanopt-cli/blob/develop/LICENSE.md
4
+ # *********************************************************************************
5
+
1
6
  # frozen_string_literal: true
2
7
 
3
8
  require_relative '../resources/minitest_helper'
@@ -8,28 +13,29 @@ require_relative '../measure.rb'
8
13
  require_relative '../resources/util.rb'
9
14
  require_relative 'util.rb'
10
15
 
11
- class HPXMLtoOpenStudioHVACTest < MiniTest::Test
12
- def sample_files_dir
13
- return File.join(File.dirname(__FILE__), '..', '..', 'workflow', 'sample_files')
16
+ class HPXMLtoOpenStudioHVACTest < Minitest::Test
17
+ def setup
18
+ @root_path = File.absolute_path(File.join(File.dirname(__FILE__), '..', '..'))
19
+ @sample_files_path = File.join(@root_path, 'workflow', 'sample_files')
20
+ @tmp_hpxml_path = File.join(@sample_files_path, 'tmp.xml')
21
+ end
22
+
23
+ def teardown
24
+ File.delete(@tmp_hpxml_path) if File.exist? @tmp_hpxml_path
14
25
  end
15
26
 
16
27
  def test_central_air_conditioner_1_speed
17
28
  ['base-hvac-central-ac-only-1-speed.xml',
18
29
  'base-hvac-central-ac-only-1-speed-seer2.xml'].each do |hpxml_path|
19
30
  args_hash = {}
20
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, hpxml_path))
21
- model, hpxml = _test_measure(args_hash)
22
-
23
- # Get HPXML values
24
- cooling_system = hpxml.cooling_systems[0]
25
- capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
31
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, hpxml_path))
32
+ model, _hpxml, _hpxml_bldg = _test_measure(args_hash)
26
33
 
27
34
  # Check cooling coil
28
35
  assert_equal(1, model.getCoilCoolingDXSingleSpeeds.size)
29
36
  clg_coil = model.getCoilCoolingDXSingleSpeeds[0]
30
- cop = 3.73 # Expected value
31
- assert_in_epsilon(cop, clg_coil.ratedCOP, 0.01)
32
- assert_in_epsilon(capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01)
37
+ assert_in_epsilon(3.77, clg_coil.ratedCOP, 0.01)
38
+ assert_in_epsilon(7230, clg_coil.ratedTotalCoolingCapacity.get, 0.01)
33
39
 
34
40
  # Check EMS
35
41
  assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
@@ -41,21 +47,19 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
41
47
 
42
48
  def test_central_air_conditioner_2_speed
43
49
  args_hash = {}
44
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-central-ac-only-2-speed.xml'))
45
- model, hpxml = _test_measure(args_hash)
46
-
47
- # Get HPXML values
48
- cooling_system = hpxml.cooling_systems[0]
49
- capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
50
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-central-ac-only-2-speed.xml'))
51
+ model, _hpxml, _hpxml_bldg = _test_measure(args_hash)
50
52
 
51
53
  # Check cooling coil
52
54
  assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
53
55
  clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
54
- cops = [4.95, 4.59] # Expected values
55
- cops.each_with_index do |cop, i|
56
+ assert_equal(2, clg_coil.stages.size)
57
+ [4.95, 4.53].each_with_index do |cop, i|
56
58
  assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
57
59
  end
58
- assert_in_epsilon(capacity, clg_coil.stages[-1].grossRatedTotalCoolingCapacity.get, 0.01)
60
+ [5143, 7158].each_with_index do |capacity, i|
61
+ assert_in_epsilon(capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
62
+ end
59
63
 
60
64
  # Check EMS
61
65
  assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
@@ -66,21 +70,19 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
66
70
 
67
71
  def test_central_air_conditioner_var_speed
68
72
  args_hash = {}
69
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-central-ac-only-var-speed.xml'))
70
- model, hpxml = _test_measure(args_hash)
71
-
72
- # Get HPXML values
73
- cooling_system = hpxml.cooling_systems[0]
74
- capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
73
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-central-ac-only-var-speed.xml'))
74
+ model, _hpxml, _hpxml_bldg = _test_measure(args_hash)
75
75
 
76
76
  # Check cooling coil
77
77
  assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
78
78
  clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
79
- cops = [6.57, 6.81, 6.63, 6.14] # Expected values
80
- cops.each_with_index do |cop, i|
79
+ assert_equal(2, clg_coil.stages.size)
80
+ [5.89, 5.25].each_with_index do |cop, i|
81
81
  assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
82
82
  end
83
- assert_in_epsilon(capacity, clg_coil.stages[-1].grossRatedTotalCoolingCapacity.get, 0.01)
83
+ [2780, 7169].each_with_index do |capacity, i|
84
+ assert_in_epsilon(capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
85
+ end
84
86
 
85
87
  # Check EMS
86
88
  assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
@@ -91,11 +93,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
91
93
 
92
94
  def test_room_air_conditioner
93
95
  args_hash = {}
94
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-room-ac-only.xml'))
95
- model, hpxml = _test_measure(args_hash)
96
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-room-ac-only.xml'))
97
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
96
98
 
97
99
  # Get HPXML values
98
- cooling_system = hpxml.cooling_systems[0]
100
+ cooling_system = hpxml_bldg.cooling_systems[0]
99
101
  eer = cooling_system.cooling_efficiency_eer
100
102
  ceer = eer / 1.01 # convert to ceer
101
103
  cop = UnitConversions.convert(ceer, 'Btu/hr', 'W') # Expected value
@@ -110,11 +112,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
110
112
 
111
113
  def test_room_air_conditioner_ceer
112
114
  args_hash = {}
113
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-room-ac-only-ceer.xml'))
114
- model, hpxml = _test_measure(args_hash)
115
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-room-ac-only-ceer.xml'))
116
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
115
117
 
116
118
  # Get HPXML values
117
- cooling_system = hpxml.cooling_systems[0]
119
+ cooling_system = hpxml_bldg.cooling_systems[0]
118
120
  ceer = cooling_system.cooling_efficiency_ceer
119
121
  cop = UnitConversions.convert(ceer, 'Btu/hr', 'W') # Expected value
120
122
  capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
@@ -128,11 +130,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
128
130
 
129
131
  def test_room_ac_with_heating
130
132
  args_hash = {}
131
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-room-ac-with-heating.xml'))
132
- model, hpxml = _test_measure(args_hash)
133
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-room-ac-with-heating.xml'))
134
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
133
135
 
134
136
  # Get HPXML values
135
- cooling_system = hpxml.cooling_systems[0]
137
+ cooling_system = hpxml_bldg.cooling_systems[0]
136
138
  eer = cooling_system.cooling_efficiency_eer
137
139
  ceer = eer / 1.01 # convert to ceer
138
140
  cop = UnitConversions.convert(ceer, 'Btu/hr', 'W') # Expected value
@@ -158,11 +160,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
158
160
 
159
161
  def test_ptac
160
162
  args_hash = {}
161
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-ptac.xml'))
162
- model, hpxml = _test_measure(args_hash)
163
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-ptac.xml'))
164
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
163
165
 
164
166
  # Get HPXML values
165
- cooling_system = hpxml.cooling_systems[0]
167
+ cooling_system = hpxml_bldg.cooling_systems[0]
166
168
  eer = cooling_system.cooling_efficiency_eer
167
169
  ceer = eer / 1.01 # convert to ceer
168
170
  cop = UnitConversions.convert(ceer, 'Btu/hr', 'W') # Expected value
@@ -178,11 +180,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
178
180
 
179
181
  def test_ptac_with_heating_electricity
180
182
  args_hash = {}
181
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-ptac-with-heating-electricity.xml'))
182
- model, hpxml = _test_measure(args_hash)
183
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-ptac-with-heating-electricity.xml'))
184
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
183
185
 
184
186
  # Get HPXML values
185
- cooling_system = hpxml.cooling_systems[0]
187
+ cooling_system = hpxml_bldg.cooling_systems[0]
186
188
  eer = cooling_system.cooling_efficiency_eer
187
189
  ceer = eer / 1.01 # convert to ceer
188
190
  cop = UnitConversions.convert(ceer, 'Btu/hr', 'W') # Expected value
@@ -208,11 +210,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
208
210
 
209
211
  def test_ptac_with_heating_gas
210
212
  args_hash = {}
211
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-ptac-with-heating-electricity.xml'))
212
- model, hpxml = _test_measure(args_hash)
213
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-ptac-with-heating-electricity.xml'))
214
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
213
215
 
214
216
  # Get HPXML values
215
- cooling_system = hpxml.cooling_systems[0]
217
+ cooling_system = hpxml_bldg.cooling_systems[0]
216
218
  eer = cooling_system.cooling_efficiency_eer
217
219
  ceer = eer / 1.01 # convert to ceer
218
220
  cop = UnitConversions.convert(ceer, 'Btu/hr', 'W') # Expected value
@@ -238,11 +240,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
238
240
 
239
241
  def test_pthp
240
242
  args_hash = {}
241
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-pthp.xml'))
242
- model, hpxml = _test_measure(args_hash)
243
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-pthp.xml'))
244
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
243
245
 
244
246
  # Get HPXML values
245
- heat_pump = hpxml.heat_pumps[0]
247
+ heat_pump = hpxml_bldg.heat_pumps[0]
246
248
  backup_efficiency = heat_pump.backup_heating_efficiency_percent
247
249
  clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
248
250
  htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
@@ -273,11 +275,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
273
275
 
274
276
  def test_room_heat_pump
275
277
  args_hash = {}
276
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-room-ac-with-reverse-cycle.xml'))
277
- model, hpxml = _test_measure(args_hash)
278
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-room-ac-with-reverse-cycle.xml'))
279
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
278
280
 
279
281
  # Get HPXML values
280
- heat_pump = hpxml.heat_pumps[0]
282
+ heat_pump = hpxml_bldg.heat_pumps[0]
281
283
  clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
282
284
  htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
283
285
  supp_htg_capacity = UnitConversions.convert(heat_pump.backup_heating_capacity, 'Btu/hr', 'W')
@@ -310,11 +312,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
310
312
 
311
313
  def test_furnace_gas
312
314
  args_hash = {}
313
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-furnace-gas-only.xml'))
314
- model, hpxml = _test_measure(args_hash)
315
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-furnace-gas-only.xml'))
316
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
315
317
 
316
318
  # Get HPXML values
317
- heating_system = hpxml.heating_systems[0]
319
+ heating_system = hpxml_bldg.heating_systems[0]
318
320
  afue = heating_system.heating_efficiency_afue
319
321
  capacity = UnitConversions.convert(heating_system.heating_capacity, 'Btu/hr', 'W')
320
322
  fuel = heating_system.heating_system_fuel
@@ -329,11 +331,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
329
331
 
330
332
  def test_furnace_electric
331
333
  args_hash = {}
332
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-furnace-elec-only.xml'))
333
- model, hpxml = _test_measure(args_hash)
334
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-furnace-elec-only.xml'))
335
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
334
336
 
335
337
  # Get HPXML values
336
- heating_system = hpxml.heating_systems[0]
338
+ heating_system = hpxml_bldg.heating_systems[0]
337
339
  afue = heating_system.heating_efficiency_afue
338
340
  capacity = UnitConversions.convert(heating_system.heating_capacity, 'Btu/hr', 'W')
339
341
 
@@ -346,11 +348,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
346
348
 
347
349
  def test_boiler_gas
348
350
  args_hash = {}
349
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-boiler-gas-only.xml'))
350
- model, hpxml = _test_measure(args_hash)
351
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-boiler-gas-only.xml'))
352
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
351
353
 
352
354
  # Get HPXML values
353
- heating_system = hpxml.heating_systems[0]
355
+ heating_system = hpxml_bldg.heating_systems[0]
354
356
  afue = heating_system.heating_efficiency_afue
355
357
  capacity = UnitConversions.convert(heating_system.heating_capacity, 'Btu/hr', 'W')
356
358
  fuel = heating_system.heating_system_fuel
@@ -365,11 +367,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
365
367
 
366
368
  def test_boiler_coal
367
369
  args_hash = {}
368
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-boiler-coal-only.xml'))
369
- model, hpxml = _test_measure(args_hash)
370
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-boiler-coal-only.xml'))
371
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
370
372
 
371
373
  # Get HPXML values
372
- heating_system = hpxml.heating_systems[0]
374
+ heating_system = hpxml_bldg.heating_systems[0]
373
375
  afue = heating_system.heating_efficiency_afue
374
376
  capacity = UnitConversions.convert(heating_system.heating_capacity, 'Btu/hr', 'W')
375
377
  fuel = heating_system.heating_system_fuel
@@ -384,11 +386,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
384
386
 
385
387
  def test_boiler_electric
386
388
  args_hash = {}
387
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-boiler-elec-only.xml'))
388
- model, hpxml = _test_measure(args_hash)
389
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-boiler-elec-only.xml'))
390
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
389
391
 
390
392
  # Get HPXML values
391
- heating_system = hpxml.heating_systems[0]
393
+ heating_system = hpxml_bldg.heating_systems[0]
392
394
  afue = heating_system.heating_efficiency_afue
393
395
  capacity = UnitConversions.convert(heating_system.heating_capacity, 'Btu/hr', 'W')
394
396
  fuel = heating_system.heating_system_fuel
@@ -403,11 +405,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
403
405
 
404
406
  def test_electric_resistance
405
407
  args_hash = {}
406
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-elec-resistance-only.xml'))
407
- model, hpxml = _test_measure(args_hash)
408
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-elec-resistance-only.xml'))
409
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
408
410
 
409
411
  # Get HPXML values
410
- heating_system = hpxml.heating_systems[0]
412
+ heating_system = hpxml_bldg.heating_systems[0]
411
413
  efficiency = heating_system.heating_efficiency_percent
412
414
  capacity = UnitConversions.convert(heating_system.heating_capacity, 'Btu/hr', 'W')
413
415
 
@@ -420,11 +422,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
420
422
 
421
423
  def test_stove_oil
422
424
  args_hash = {}
423
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-stove-oil-only.xml'))
424
- model, hpxml = _test_measure(args_hash)
425
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-stove-oil-only.xml'))
426
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
425
427
 
426
428
  # Get HPXML values
427
- heating_system = hpxml.heating_systems[0]
429
+ heating_system = hpxml_bldg.heating_systems[0]
428
430
  efficiency = heating_system.heating_efficiency_percent
429
431
  capacity = UnitConversions.convert(heating_system.heating_capacity, 'Btu/hr', 'W')
430
432
  fuel = heating_system.heating_system_fuel
@@ -441,29 +443,25 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
441
443
  ['base-hvac-air-to-air-heat-pump-1-speed.xml',
442
444
  'base-hvac-air-to-air-heat-pump-1-speed-seer2-hspf2.xml'].each do |hpxml_path|
443
445
  args_hash = {}
444
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, hpxml_path))
445
- model, hpxml = _test_measure(args_hash)
446
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, hpxml_path))
447
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
446
448
 
447
449
  # Get HPXML values
448
- heat_pump = hpxml.heat_pumps[0]
450
+ heat_pump = hpxml_bldg.heat_pumps[0]
449
451
  backup_efficiency = heat_pump.backup_heating_efficiency_percent
450
- clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
451
- htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
452
452
  supp_htg_capacity = UnitConversions.convert(heat_pump.backup_heating_capacity, 'Btu/hr', 'W')
453
453
 
454
454
  # Check cooling coil
455
455
  assert_equal(1, model.getCoilCoolingDXSingleSpeeds.size)
456
456
  clg_coil = model.getCoilCoolingDXSingleSpeeds[0]
457
- cop = 3.73 # Expected value
458
- assert_in_epsilon(cop, clg_coil.ratedCOP, 0.01)
459
- assert_in_epsilon(clg_capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01)
457
+ assert_in_epsilon(3.77, clg_coil.ratedCOP, 0.01)
458
+ assert_in_epsilon(10846, clg_coil.ratedTotalCoolingCapacity.get, 0.01)
460
459
 
461
460
  # Check heating coil
462
461
  assert_equal(1, model.getCoilHeatingDXSingleSpeeds.size)
463
462
  htg_coil = model.getCoilHeatingDXSingleSpeeds[0]
464
- cop = 3.28 # Expected value
465
- assert_in_epsilon(cop, htg_coil.ratedCOP, 0.01)
466
- assert_in_epsilon(htg_capacity, htg_coil.ratedTotalHeatingCapacity.get, 0.01)
463
+ assert_in_epsilon(3.29, htg_coil.ratedCOP, 0.01)
464
+ assert_in_epsilon(10262, htg_coil.ratedTotalHeatingCapacity.get, 0.01)
467
465
 
468
466
  # Check supp heating coil
469
467
  assert_equal(1, model.getCoilHeatingElectrics.size)
@@ -487,11 +485,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
487
485
  'base-hvac-mini-split-heat-pump-ductless.xml',
488
486
  'base-hvac-mini-split-heat-pump-ductless-backup-baseboard.xml'].each do |hpxml_name|
489
487
  args_hash = {}
490
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, hpxml_name))
491
- model, hpxml = _test_measure(args_hash)
488
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, hpxml_name))
489
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
492
490
 
493
491
  # Get HPXML values
494
- heat_pump = hpxml.heat_pumps[0]
492
+ heat_pump = hpxml_bldg.heat_pumps[0]
495
493
  if not heat_pump.backup_heating_switchover_temp.nil?
496
494
  backup_lockout_temp = UnitConversions.convert(heat_pump.backup_heating_switchover_temp, 'F', 'C')
497
495
  compressor_lockout_temp = UnitConversions.convert(heat_pump.backup_heating_switchover_temp, 'F', 'C')
@@ -522,33 +520,35 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
522
520
 
523
521
  def test_air_to_air_heat_pump_2_speed
524
522
  args_hash = {}
525
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-air-to-air-heat-pump-2-speed.xml'))
526
- model, hpxml = _test_measure(args_hash)
523
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-air-to-air-heat-pump-2-speed.xml'))
524
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
527
525
 
528
526
  # Get HPXML values
529
- heat_pump = hpxml.heat_pumps[0]
527
+ heat_pump = hpxml_bldg.heat_pumps[0]
530
528
  backup_efficiency = heat_pump.backup_heating_efficiency_percent
531
- clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
532
- htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
533
529
  supp_htg_capacity = UnitConversions.convert(heat_pump.backup_heating_capacity, 'Btu/hr', 'W')
534
530
 
535
531
  # Check cooling coil
536
532
  assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
537
533
  clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
538
- cops = [4.95, 4.59] # Expected values
539
- cops.each_with_index do |cop, i|
534
+ assert_equal(2, clg_coil.stages.size)
535
+ [4.95, 4.53].each_with_index do |cop, i|
540
536
  assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
541
537
  end
542
- assert_in_epsilon(clg_capacity, clg_coil.stages[-1].grossRatedTotalCoolingCapacity.get, 0.01)
538
+ [7715, 10736].each_with_index do |clg_capacity, i|
539
+ assert_in_epsilon(clg_capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
540
+ end
543
541
 
544
542
  # Check heating coil
545
543
  assert_equal(1, model.getCoilHeatingDXMultiSpeeds.size)
546
544
  htg_coil = model.getCoilHeatingDXMultiSpeeds[0]
547
- cops = [4.52, 4.08] # Expected values
548
- cops.each_with_index do |cop, i|
545
+ assert_equal(2, htg_coil.stages.size)
546
+ [4.52, 3.93].each_with_index do |cop, i|
549
547
  assert_in_epsilon(cop, htg_coil.stages[i].grossRatedHeatingCOP, 0.01)
550
548
  end
551
- assert_in_epsilon(htg_capacity, htg_coil.stages[-1].grossRatedHeatingCapacity.get, 0.01)
549
+ [7499, 10360].each_with_index do |htg_capacity, i|
550
+ assert_in_epsilon(htg_capacity, htg_coil.stages[i].grossRatedHeatingCapacity.get, 0.01)
551
+ end
552
552
 
553
553
  # Check supp heating coil
554
554
  assert_equal(1, model.getCoilHeatingElectrics.size)
@@ -565,33 +565,35 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
565
565
 
566
566
  def test_air_to_air_heat_pump_var_speed
567
567
  args_hash = {}
568
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-air-to-air-heat-pump-var-speed.xml'))
569
- model, hpxml = _test_measure(args_hash)
568
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-air-to-air-heat-pump-var-speed.xml'))
569
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
570
570
 
571
571
  # Get HPXML values
572
- heat_pump = hpxml.heat_pumps[0]
572
+ heat_pump = hpxml_bldg.heat_pumps[0]
573
573
  backup_efficiency = heat_pump.backup_heating_efficiency_percent
574
- clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
575
- htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
576
574
  supp_htg_capacity = UnitConversions.convert(heat_pump.backup_heating_capacity, 'Btu/hr', 'W')
577
575
 
578
576
  # Check cooling coil
579
577
  assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
580
578
  clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
581
- cops = [5.93, 6.15, 5.98, 5.54] # Expected values
582
- cops.each_with_index do |cop, i|
579
+ assert_equal(2, clg_coil.stages.size)
580
+ [5.39, 4.77].each_with_index do |cop, i|
583
581
  assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
584
582
  end
585
- assert_in_epsilon(clg_capacity, clg_coil.stages[-1].grossRatedTotalCoolingCapacity.get, 0.01)
583
+ [4169, 10753].each_with_index do |clg_capacity, i|
584
+ assert_in_epsilon(clg_capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
585
+ end
586
586
 
587
587
  # Check heating coil
588
588
  assert_equal(1, model.getCoilHeatingDXMultiSpeeds.size)
589
589
  htg_coil = model.getCoilHeatingDXMultiSpeeds[0]
590
- cops = [5.67, 4.84, 4.09, 3.91] # Expected values
591
- cops.each_with_index do |cop, i|
590
+ assert_equal(2, htg_coil.stages.size)
591
+ [4.56, 3.89].each_with_index do |cop, i|
592
592
  assert_in_epsilon(cop, htg_coil.stages[i].grossRatedHeatingCOP, 0.01)
593
593
  end
594
- assert_in_epsilon(htg_capacity, htg_coil.stages[-2].grossRatedHeatingCapacity.get, 0.01)
594
+ [3876, 10634].each_with_index do |htg_capacity, i|
595
+ assert_in_epsilon(htg_capacity, htg_coil.stages[i].grossRatedHeatingCapacity.get, 0.01)
596
+ end
595
597
 
596
598
  # Check supp heating coil
597
599
  assert_equal(1, model.getCoilHeatingElectrics.size)
@@ -606,33 +608,77 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
606
608
  assert(program_values.empty?) # Check no EMS program
607
609
  end
608
610
 
609
- def test_mini_split_heat_pump
611
+ def test_air_to_air_heat_pump_var_speed_detailed_performance
610
612
  args_hash = {}
611
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-mini-split-heat-pump-ductless.xml'))
612
- model, hpxml = _test_measure(args_hash)
613
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-air-to-air-heat-pump-var-speed-detailed-performance.xml'))
614
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
613
615
 
614
616
  # Get HPXML values
615
- heat_pump = hpxml.heat_pumps[0]
616
- clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
617
- htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
617
+ heat_pump = hpxml_bldg.heat_pumps[0]
618
618
 
619
619
  # Check cooling coil
620
620
  assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
621
621
  clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
622
- cops = [5.76, 4.99, 4.19, 3.10] # Expected values
623
- cops.each_with_index do |cop, i|
622
+ assert_equal(2, clg_coil.stages.size)
623
+ [4.51, 2.88].each_with_index do |cop, i|
624
624
  assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
625
625
  end
626
- assert_in_epsilon(clg_capacity * 1.2, clg_coil.stages[-1].grossRatedTotalCoolingCapacity.get, 0.01)
626
+ [3435, 10726].each_with_index do |clg_capacity, i|
627
+ assert_in_epsilon(clg_capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
628
+ end
627
629
 
628
630
  # Check heating coil
629
631
  assert_equal(1, model.getCoilHeatingDXMultiSpeeds.size)
630
632
  htg_coil = model.getCoilHeatingDXMultiSpeeds[0]
631
- cops = [5.42, 4.34, 3.98, 3.60] # Expected values
632
- cops.each_with_index do |cop, i|
633
+ assert_equal(2, htg_coil.stages.size)
634
+ [4.75, 3.59].each_with_index do |cop, i|
633
635
  assert_in_epsilon(cop, htg_coil.stages[i].grossRatedHeatingCOP, 0.01)
634
636
  end
635
- assert_in_epsilon(htg_capacity * 1.2, htg_coil.stages[-1].grossRatedHeatingCapacity.get, 0.01)
637
+ [2927, 10376].each_with_index do |htg_capacity, i|
638
+ assert_in_epsilon(htg_capacity, htg_coil.stages[i].grossRatedHeatingCapacity.get, 0.01)
639
+ end
640
+
641
+ # Check supp heating coil
642
+ backup_efficiency = heat_pump.backup_heating_efficiency_percent
643
+ supp_htg_capacity = UnitConversions.convert(heat_pump.backup_heating_capacity, 'Btu/hr', 'W')
644
+ assert_equal(1, model.getCoilHeatingElectrics.size)
645
+ supp_htg_coil = model.getCoilHeatingElectrics[0]
646
+ assert_in_epsilon(backup_efficiency, supp_htg_coil.efficiency, 0.01)
647
+ assert_in_epsilon(supp_htg_capacity, supp_htg_coil.nominalCapacity.get, 0.01)
648
+
649
+ # Check EMS
650
+ assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
651
+ unitary_system = model.getAirLoopHVACUnitarySystems[0]
652
+ program_values = get_ems_values(model.getEnergyManagementSystemPrograms, "#{unitary_system.name} IQ")
653
+ assert(program_values.empty?) # Check no EMS program
654
+ end
655
+
656
+ def test_mini_split_heat_pump
657
+ args_hash = {}
658
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-mini-split-heat-pump-ductless.xml'))
659
+ model, _hpxml, _hpxml_bldg = _test_measure(args_hash)
660
+
661
+ # Check cooling coil
662
+ assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
663
+ clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
664
+ assert_equal(2, clg_coil.stages.size)
665
+ [4.40, 3.20].each_with_index do |cop, i|
666
+ assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
667
+ end
668
+ [2691, 10606].each_with_index do |clg_capacity, i|
669
+ assert_in_epsilon(clg_capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
670
+ end
671
+
672
+ # Check heating coil
673
+ assert_equal(1, model.getCoilHeatingDXMultiSpeeds.size)
674
+ htg_coil = model.getCoilHeatingDXMultiSpeeds[0]
675
+ assert_equal(2, htg_coil.stages.size)
676
+ [4.63, 3.31].each_with_index do |cop, i|
677
+ assert_in_epsilon(cop, htg_coil.stages[i].grossRatedHeatingCOP, 0.01)
678
+ end
679
+ [3273, 12890].each_with_index do |htg_capacity, i|
680
+ assert_in_epsilon(htg_capacity, htg_coil.stages[i].grossRatedHeatingCapacity.get, 0.01)
681
+ end
636
682
 
637
683
  # Check supp heating coil
638
684
  assert_equal(0, model.getCoilHeatingElectrics.size)
@@ -644,23 +690,58 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
644
690
  assert(program_values.empty?) # Check no EMS program
645
691
  end
646
692
 
647
- def test_mini_split_air_conditioner
693
+ def test_mini_split_heat_pump_detailed_performance
648
694
  args_hash = {}
649
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-mini-split-air-conditioner-only-ductless.xml'))
650
- model, hpxml = _test_measure(args_hash)
695
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-mini-split-heat-pump-ductless-detailed-performance.xml'))
696
+ model, _hpxml = _test_measure(args_hash)
651
697
 
652
- # Get HPXML values
653
- cooling_system = hpxml.cooling_systems[0]
654
- clg_capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
698
+ # Check cooling coil
699
+ assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
700
+ clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
701
+ assert_equal(2, clg_coil.stages.size)
702
+ [4.06, 3.33].each_with_index do |cop, i|
703
+ assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
704
+ end
705
+ [3041, 12557].each_with_index do |clg_capacity, i|
706
+ assert_in_epsilon(clg_capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
707
+ end
708
+
709
+ # Check heating coil
710
+ assert_equal(1, model.getCoilHeatingDXMultiSpeeds.size)
711
+ htg_coil = model.getCoilHeatingDXMultiSpeeds[0]
712
+ assert_equal(2, htg_coil.stages.size)
713
+ [4.82, 3.23].each_with_index do |cop, i|
714
+ assert_in_epsilon(cop, htg_coil.stages[i].grossRatedHeatingCOP, 0.01)
715
+ end
716
+ [3557, 16426].each_with_index do |htg_capacity, i|
717
+ assert_in_epsilon(htg_capacity, htg_coil.stages[i].grossRatedHeatingCapacity.get, 0.01)
718
+ end
719
+
720
+ # Check supp heating coil
721
+ assert_equal(0, model.getCoilHeatingElectrics.size)
722
+
723
+ # Check EMS
724
+ assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
725
+ unitary_system = model.getAirLoopHVACUnitarySystems[0]
726
+ program_values = get_ems_values(model.getEnergyManagementSystemPrograms, "#{unitary_system.name} IQ")
727
+ assert(program_values.empty?) # Check no EMS program
728
+ end
729
+
730
+ def test_mini_split_air_conditioner
731
+ args_hash = {}
732
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-mini-split-air-conditioner-only-ductless.xml'))
733
+ model, _hpxml, _hpxml_bldg = _test_measure(args_hash)
655
734
 
656
735
  # Check cooling coil
657
736
  assert_equal(1, model.getCoilCoolingDXMultiSpeeds.size)
658
737
  clg_coil = model.getCoilCoolingDXMultiSpeeds[0]
659
- cops = [5.76, 4.99, 4.19, 3.10] # Expected values
660
- cops.each_with_index do |cop, i|
738
+ assert_equal(2, clg_coil.stages.size)
739
+ [4.40, 3.23].each_with_index do |cop, i|
661
740
  assert_in_epsilon(cop, clg_coil.stages[i].grossRatedCoolingCOP, 0.01)
662
741
  end
663
- assert_in_epsilon(clg_capacity * 1.2, clg_coil.stages[-1].grossRatedTotalCoolingCapacity.get, 0.01)
742
+ [1794, 7086].each_with_index do |clg_capacity, i|
743
+ assert_in_epsilon(clg_capacity, clg_coil.stages[i].grossRatedTotalCoolingCapacity.get, 0.01)
744
+ end
664
745
 
665
746
  # Check EMS
666
747
  assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
@@ -671,11 +752,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
671
752
 
672
753
  def test_ground_to_air_heat_pump
673
754
  args_hash = {}
674
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-ground-to-air-heat-pump.xml'))
675
- model, hpxml = _test_measure(args_hash)
755
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-ground-to-air-heat-pump.xml'))
756
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
676
757
 
677
758
  # Get HPXML values
678
- heat_pump = hpxml.heat_pumps[0]
759
+ heat_pump = hpxml_bldg.heat_pumps[0]
679
760
  backup_efficiency = heat_pump.backup_heating_efficiency_percent
680
761
  clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
681
762
  htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
@@ -684,15 +765,13 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
684
765
  # Check cooling coil
685
766
  assert_equal(1, model.getCoilCoolingWaterToAirHeatPumpEquationFits.size)
686
767
  clg_coil = model.getCoilCoolingWaterToAirHeatPumpEquationFits[0]
687
- cop = 5.36 # Expected values
688
- assert_in_epsilon(cop, clg_coil.ratedCoolingCoefficientofPerformance, 0.01)
768
+ assert_in_epsilon(4.87, clg_coil.ratedCoolingCoefficientofPerformance, 0.01)
689
769
  assert_in_epsilon(clg_capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01)
690
770
 
691
771
  # Check heating coil
692
772
  assert_equal(1, model.getCoilHeatingWaterToAirHeatPumpEquationFits.size)
693
773
  htg_coil = model.getCoilHeatingWaterToAirHeatPumpEquationFits[0]
694
- cop = 3.65 # Expected values
695
- assert_in_epsilon(cop, htg_coil.ratedHeatingCoefficientofPerformance, 0.01)
774
+ assert_in_epsilon(3.6, htg_coil.ratedHeatingCoefficientofPerformance, 0.01)
696
775
  assert_in_epsilon(htg_capacity, htg_coil.ratedHeatingCapacity.get, 0.01)
697
776
 
698
777
  # Check supp heating coil
@@ -706,83 +785,95 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
706
785
  unitary_system = model.getAirLoopHVACUnitarySystems[0]
707
786
  program_values = get_ems_values(model.getEnergyManagementSystemPrograms, "#{unitary_system.name} IQ")
708
787
  assert(program_values.empty?) # Check no EMS program
788
+
789
+ # Check ghx
790
+ assert(1, model.getGroundHeatExchangerVerticals.size)
791
+ ghx = model.getGroundHeatExchangerVerticals[0]
792
+
793
+ # Check xing
794
+ assert(1, model.getSiteGroundTemperatureUndisturbedXings.size)
795
+ xing = model.getSiteGroundTemperatureUndisturbedXings[0]
796
+ assert_in_epsilon(ghx.groundThermalConductivity.get, xing.soilThermalConductivity, 0.01)
797
+ assert_in_epsilon(962, xing.soilDensity, 0.01)
798
+ assert_in_epsilon(ghx.groundThermalHeatCapacity.get / xing.soilDensity, xing.soilSpecificHeat, 0.01)
799
+ assert_in_epsilon(ghx.groundTemperature.get, xing.averageSoilSurfaceTemperature, 0.01)
800
+ assert_in_epsilon(12.5, xing.soilSurfaceTemperatureAmplitude1, 0.01)
801
+ assert_in_epsilon(-1.3, xing.soilSurfaceTemperatureAmplitude2, 0.01)
802
+ assert_in_epsilon(20, xing.phaseShiftofTemperatureAmplitude1, 0.01)
803
+ assert_in_epsilon(31, xing.phaseShiftofTemperatureAmplitude2, 0.01)
709
804
  end
710
805
 
711
806
  def test_shared_chiller_baseboard
712
807
  args_hash = {}
713
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-chiller-only-baseboard.xml'))
714
- model, hpxml = _test_measure(args_hash)
808
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-chiller-only-baseboard.xml'))
809
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
715
810
 
716
811
  # Get HPXML values
717
- cooling_system = hpxml.cooling_systems[0]
812
+ cooling_system = hpxml_bldg.cooling_systems[0]
718
813
  capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
719
814
 
720
815
  # Check cooling coil
721
816
  assert_equal(1, model.getCoilCoolingDXSingleSpeeds.size)
722
817
  clg_coil = model.getCoilCoolingDXSingleSpeeds[0]
723
- cop = 3.85 # Expected value
724
- assert_in_epsilon(cop, clg_coil.ratedCOP, 0.01)
818
+ assert_in_epsilon(3.62, clg_coil.ratedCOP, 0.01)
725
819
  refute_in_epsilon(capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01) # Uses autosized capacity
726
820
  end
727
821
 
728
822
  def test_shared_chiller_fan_coil
729
823
  args_hash = {}
730
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml'))
731
- model, hpxml = _test_measure(args_hash)
824
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-chiller-only-fan-coil.xml'))
825
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
732
826
 
733
827
  # Get HPXML values
734
- cooling_system = hpxml.cooling_systems[0]
828
+ cooling_system = hpxml_bldg.cooling_systems[0]
735
829
  capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
736
830
 
737
831
  # Check cooling coil
738
832
  assert_equal(1, model.getCoilCoolingDXSingleSpeeds.size)
739
833
  clg_coil = model.getCoilCoolingDXSingleSpeeds[0]
740
- cop = 3.45 # Expected value
741
- assert_in_epsilon(cop, clg_coil.ratedCOP, 0.01)
834
+ assert_in_epsilon(3.31, clg_coil.ratedCOP, 0.01)
742
835
  refute_in_epsilon(capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01) # Uses autosized capacity
743
836
  end
744
837
 
745
838
  def test_shared_chiller_water_loop_heat_pump
746
839
  args_hash = {}
747
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml'))
748
- model, hpxml = _test_measure(args_hash)
840
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-chiller-only-water-loop-heat-pump.xml'))
841
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
749
842
 
750
843
  # Get HPXML values
751
- cooling_system = hpxml.cooling_systems[0]
844
+ cooling_system = hpxml_bldg.cooling_systems[0]
752
845
  capacity = UnitConversions.convert(cooling_system.cooling_capacity, 'Btu/hr', 'W')
753
846
 
754
847
  # Check cooling coil
755
848
  assert_equal(1, model.getCoilCoolingDXSingleSpeeds.size)
756
849
  clg_coil = model.getCoilCoolingDXSingleSpeeds[0]
757
- cop = 1.30 # Expected value
758
- assert_in_epsilon(cop, clg_coil.ratedCOP, 0.01)
850
+ assert_in_epsilon(1.50, clg_coil.ratedCOP, 0.01)
759
851
  refute_in_epsilon(capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01) # Uses autosized capacity
760
852
  end
761
853
 
762
854
  def test_shared_cooling_tower_water_loop_heat_pump
763
855
  args_hash = {}
764
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml'))
765
- model, hpxml = _test_measure(args_hash)
856
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-cooling-tower-only-water-loop-heat-pump.xml'))
857
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
766
858
 
767
859
  # Get HPXML values
768
- cooling_system = hpxml.cooling_systems[0]
860
+ cooling_system = hpxml_bldg.cooling_systems[0]
769
861
  capacity = UnitConversions.convert(cooling_system.cooling_capacity.to_f, 'Btu/hr', 'W')
770
862
 
771
863
  # Check cooling coil
772
864
  assert_equal(1, model.getCoilCoolingDXSingleSpeeds.size)
773
865
  clg_coil = model.getCoilCoolingDXSingleSpeeds[0]
774
- cop = 3.68 # Expected value
775
- assert_in_epsilon(cop, clg_coil.ratedCOP, 0.01)
866
+ assert_in_epsilon(3.50, clg_coil.ratedCOP, 0.01)
776
867
  refute_in_epsilon(capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01) # Uses autosized capacity
777
868
  end
778
869
 
779
870
  def test_shared_boiler_baseboard
780
871
  args_hash = {}
781
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-boiler-only-baseboard.xml'))
782
- model, hpxml = _test_measure(args_hash)
872
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-boiler-only-baseboard.xml'))
873
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
783
874
 
784
875
  # Get HPXML values
785
- heating_system = hpxml.heating_systems[0]
876
+ heating_system = hpxml_bldg.heating_systems[0]
786
877
  afue = heating_system.heating_efficiency_afue
787
878
  capacity = UnitConversions.convert(heating_system.heating_capacity.to_f, 'Btu/hr', 'W')
788
879
  fuel = heating_system.heating_system_fuel
@@ -797,11 +888,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
797
888
 
798
889
  def test_shared_boiler_fan_coil
799
890
  args_hash = {}
800
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml'))
801
- model, hpxml = _test_measure(args_hash)
891
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-boiler-only-fan-coil.xml'))
892
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
802
893
 
803
894
  # Get HPXML values
804
- heating_system = hpxml.heating_systems[0]
895
+ heating_system = hpxml_bldg.heating_systems[0]
805
896
  afue = heating_system.heating_efficiency_afue
806
897
  capacity = UnitConversions.convert(heating_system.heating_capacity.to_f, 'Btu/hr', 'W')
807
898
  fuel = heating_system.heating_system_fuel
@@ -816,15 +907,15 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
816
907
 
817
908
  def test_shared_boiler_water_loop_heat_pump
818
909
  args_hash = {}
819
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml'))
820
- model, hpxml = _test_measure(args_hash)
910
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-boiler-only-water-loop-heat-pump.xml'))
911
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
821
912
 
822
913
  # Get HPXML values
823
- heating_system = hpxml.heating_systems[0]
914
+ heating_system = hpxml_bldg.heating_systems[0]
824
915
  afue = heating_system.heating_efficiency_afue
825
916
  capacity = UnitConversions.convert(heating_system.heating_capacity.to_f, 'Btu/hr', 'W')
826
917
  fuel = heating_system.heating_system_fuel
827
- heat_pump = hpxml.heat_pumps[0]
918
+ heat_pump = hpxml_bldg.heat_pumps[0]
828
919
  wlhp_cop = heat_pump.heating_efficiency_cop
829
920
 
830
921
  # Check boiler
@@ -849,11 +940,11 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
849
940
 
850
941
  def test_shared_ground_loop_ground_to_air_heat_pump
851
942
  args_hash = {}
852
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml'))
853
- model, hpxml = _test_measure(args_hash)
943
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-bldgtype-mf-unit-shared-ground-loop-ground-to-air-heat-pump.xml'))
944
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
854
945
 
855
946
  # Get HPXML values
856
- heat_pump = hpxml.heat_pumps[0]
947
+ heat_pump = hpxml_bldg.heat_pumps[0]
857
948
  backup_efficiency = heat_pump.backup_heating_efficiency_percent
858
949
  clg_capacity = UnitConversions.convert(heat_pump.cooling_capacity, 'Btu/hr', 'W')
859
950
  htg_capacity = UnitConversions.convert(heat_pump.heating_capacity, 'Btu/hr', 'W')
@@ -862,15 +953,13 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
862
953
  # Check cooling coil
863
954
  assert_equal(1, model.getCoilCoolingWaterToAirHeatPumpEquationFits.size)
864
955
  clg_coil = model.getCoilCoolingWaterToAirHeatPumpEquationFits[0]
865
- cop = 5.36 # Expected values
866
- assert_in_epsilon(cop, clg_coil.ratedCoolingCoefficientofPerformance, 0.01)
956
+ assert_in_epsilon(4.87, clg_coil.ratedCoolingCoefficientofPerformance, 0.01)
867
957
  assert_in_epsilon(clg_capacity, clg_coil.ratedTotalCoolingCapacity.get, 0.01)
868
958
 
869
959
  # Check heating coil
870
960
  assert_equal(1, model.getCoilHeatingWaterToAirHeatPumpEquationFits.size)
871
961
  htg_coil = model.getCoilHeatingWaterToAirHeatPumpEquationFits[0]
872
- cop = 3.65 # Expected values
873
- assert_in_epsilon(cop, htg_coil.ratedHeatingCoefficientofPerformance, 0.01)
962
+ assert_in_epsilon(3.6, htg_coil.ratedHeatingCoefficientofPerformance, 0.01)
874
963
  assert_in_epsilon(htg_capacity, htg_coil.ratedHeatingCapacity.get, 0.01)
875
964
 
876
965
  # Check supp heating coil
@@ -880,13 +969,13 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
880
969
  assert_in_epsilon(supp_htg_capacity, supp_htg_coil.nominalCapacity.get, 0.01)
881
970
  end
882
971
 
883
- def test_install_quality_air_to_air_heat_pump_1_speed_ratio
972
+ def test_install_quality_air_to_air_heat_pump_1_speed
884
973
  args_hash = {}
885
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-air-to-air-heat-pump-1-speed.xml'))
886
- model, hpxml = _test_measure(args_hash)
974
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-air-to-air-heat-pump-1-speed.xml'))
975
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
887
976
 
888
977
  # Get HPXML values
889
- heat_pump = hpxml.heat_pumps[0]
978
+ heat_pump = hpxml_bldg.heat_pumps[0]
890
979
  charge_defect = heat_pump.charge_defect_ratio
891
980
  fan_watts_cfm = heat_pump.fan_watts_per_cfm
892
981
 
@@ -920,34 +1009,59 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
920
1009
  assert_in_epsilon(program_values['FF_AF_htg'].sum, heating_cfm / rated_airflow_cfm_htg, 0.01)
921
1010
  end
922
1011
 
923
- def test_install_quality_air_to_air_heat_pump_2_speed_ratio
1012
+ def test_install_quality_air_to_air_heat_pump_2_speed
924
1013
  args_hash = {}
925
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-air-to-air-heat-pump-2-speed.xml'))
926
- model, hpxml = _test_measure(args_hash)
1014
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-air-to-air-heat-pump-2-speed.xml'))
1015
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
927
1016
 
928
1017
  # Get HPXML values
929
- heat_pump = hpxml.heat_pumps[0]
930
- _check_install_quality_multispeed_ratio(heat_pump, model, heat_pump)
1018
+ heat_pump = hpxml_bldg.heat_pumps[0]
1019
+ program_values = _check_install_quality_multispeed_ratio(heat_pump, model, heat_pump)
1020
+ [1.088, 1.088].each_with_index do |rated_airflow_ratio, i|
1021
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_clg'][i], 0.01)
1022
+ end
1023
+ [0.806, 0.806].each_with_index do |rated_airflow_ratio, i|
1024
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_htg'][i], 0.01)
1025
+ end
931
1026
  end
932
1027
 
933
- def test_install_quality_air_to_air_heat_pump_var_speed_ratio
1028
+ def test_install_quality_air_to_air_heat_pump_var_speed
934
1029
  args_hash = {}
935
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-air-to-air-heat-pump-var-speed.xml'))
936
- model, hpxml = _test_measure(args_hash)
1030
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-air-to-air-heat-pump-var-speed.xml'))
1031
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
1032
+
1033
+ # Get HPXML values
1034
+ heat_pump = hpxml_bldg.heat_pumps[0]
1035
+ program_values = _check_install_quality_multispeed_ratio(heat_pump, model, heat_pump)
1036
+ [0.936, 0.936].each_with_index do |rated_airflow_ratio, i|
1037
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_clg'][i], 0.01)
1038
+ end
1039
+ [0.71, 0.71].each_with_index do |rated_airflow_ratio, i|
1040
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_htg'][i], 0.01)
1041
+ end
1042
+
1043
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-air-to-air-heat-pump-var-speed-detailed-performance.xml'))
1044
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
937
1045
 
938
1046
  # Get HPXML values
939
- heat_pump = hpxml.heat_pumps[0]
940
- _check_install_quality_multispeed_ratio(heat_pump, model, heat_pump)
1047
+ heat_pump = hpxml_bldg.heat_pumps[0]
1048
+ program_values = _check_install_quality_multispeed_ratio(heat_pump, model, heat_pump)
1049
+ [0.936, 0.936].each_with_index do |rated_airflow_ratio, i|
1050
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_clg'][i], 0.01)
1051
+ end
1052
+ [0.71, 0.71].each_with_index do |rated_airflow_ratio, i|
1053
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_htg'][i], 0.01)
1054
+ end
941
1055
  end
942
1056
 
943
- def test_install_quality_furnace_central_air_conditioner_1_speed_ratio
1057
+ def test_install_quality_furnace_central_air_conditioner_1_speed
944
1058
  args_hash = {}
945
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-furnace-gas-central-ac-1-speed.xml'))
946
- model, hpxml = _test_measure(args_hash)
1059
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-furnace-gas-central-ac-1-speed.xml'))
1060
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
947
1061
 
948
1062
  # Get HPXML values
949
- cooling_system = hpxml.cooling_systems[0]
950
- heating_system = hpxml.heating_systems[0]
1063
+ cooling_system = hpxml_bldg.cooling_systems[0]
1064
+ heating_system = hpxml_bldg.heating_systems[0]
951
1065
  charge_defect = cooling_system.charge_defect_ratio
952
1066
  fan_watts_cfm = cooling_system.fan_watts_per_cfm
953
1067
  fan_watts_cfm2 = heating_system.fan_watts_per_cfm
@@ -978,33 +1092,39 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
978
1092
  assert_in_epsilon(program_values['FF_AF_clg'].sum, cooling_cfm / rated_airflow_cfm, 0.01)
979
1093
  end
980
1094
 
981
- def test_install_quality_furnace_central_air_conditioner_2_speed_ratio
1095
+ def test_install_quality_furnace_central_air_conditioner_2_speed
982
1096
  args_hash = {}
983
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-furnace-gas-central-ac-2-speed.xml'))
984
- model, hpxml = _test_measure(args_hash)
1097
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-furnace-gas-central-ac-2-speed.xml'))
1098
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
985
1099
 
986
1100
  # Get HPXML values
987
- cooling_system = hpxml.cooling_systems[0]
988
- _check_install_quality_multispeed_ratio(cooling_system, model)
1101
+ cooling_system = hpxml_bldg.cooling_systems[0]
1102
+ program_values = _check_install_quality_multispeed_ratio(cooling_system, model)
1103
+ [1.088, 1.088].each_with_index do |rated_airflow_ratio, i|
1104
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_clg'][i])
1105
+ end
989
1106
  end
990
1107
 
991
- def test_install_quality_furnace_central_air_conditioner_var_speed_ratio
1108
+ def test_install_quality_furnace_central_air_conditioner_var_speed
992
1109
  args_hash = {}
993
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-furnace-gas-central-ac-var-speed.xml'))
994
- model, hpxml = _test_measure(args_hash)
1110
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-furnace-gas-central-ac-var-speed.xml'))
1111
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
995
1112
 
996
1113
  # Get HPXML values
997
- cooling_system = hpxml.cooling_systems[0]
998
- _check_install_quality_multispeed_ratio(cooling_system, model)
1114
+ cooling_system = hpxml_bldg.cooling_systems[0]
1115
+ program_values = _check_install_quality_multispeed_ratio(cooling_system, model)
1116
+ [0.936, 0.936].each_with_index do |rated_airflow_ratio, i|
1117
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_clg'][i])
1118
+ end
999
1119
  end
1000
1120
 
1001
- def test_install_quality_furnace_gas_ratio
1121
+ def test_install_quality_furnace_gas
1002
1122
  args_hash = {}
1003
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-furnace-gas-only.xml'))
1004
- model, hpxml = _test_measure(args_hash)
1123
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-furnace-gas-only.xml'))
1124
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
1005
1125
 
1006
1126
  # Get HPXML values
1007
- heating_system = hpxml.heating_systems[0]
1127
+ heating_system = hpxml_bldg.heating_systems[0]
1008
1128
  fan_watts_cfm = heating_system.fan_watts_per_cfm
1009
1129
 
1010
1130
  assert_equal(1, model.getAirLoopHVACUnitarySystems.size)
@@ -1015,13 +1135,13 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
1015
1135
  assert_in_epsilon(fan_watts_cfm, fan.designPressureRise / fan.fanTotalEfficiency * UnitConversions.convert(1.0, 'cfm', 'm^3/s'), 0.01)
1016
1136
  end
1017
1137
 
1018
- def test_install_quality_ground_to_air_heat_pump_ratio
1138
+ def test_install_quality_ground_to_air_heat_pump
1019
1139
  args_hash = {}
1020
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-ground-to-air-heat-pump.xml'))
1021
- model, hpxml = _test_measure(args_hash)
1140
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-ground-to-air-heat-pump.xml'))
1141
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
1022
1142
 
1023
1143
  # Get HPXML values
1024
- heat_pump = hpxml.heat_pumps[0]
1144
+ heat_pump = hpxml_bldg.heat_pumps[0]
1025
1145
  charge_defect = heat_pump.charge_defect_ratio
1026
1146
  fan_watts_cfm = heat_pump.fan_watts_per_cfm
1027
1147
 
@@ -1055,33 +1175,42 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
1055
1175
  assert_in_epsilon(program_values['FF_AF_htg'].sum, heating_cfm / rated_airflow_cfm_htg, 0.01)
1056
1176
  end
1057
1177
 
1058
- def test_install_quality_mini_split_air_conditioner_ratio
1178
+ def test_install_quality_mini_split_air_conditioner
1059
1179
  args_hash = {}
1060
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-mini-split-air-conditioner-only-ducted.xml'))
1061
- model, hpxml = _test_measure(args_hash)
1180
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-mini-split-air-conditioner-only-ducted.xml'))
1181
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
1062
1182
 
1063
1183
  # Get HPXML values
1064
- cooling_system = hpxml.cooling_systems[0]
1065
- _check_install_quality_multispeed_ratio(cooling_system, model)
1184
+ cooling_system = hpxml_bldg.cooling_systems[0]
1185
+ program_values = _check_install_quality_multispeed_ratio(cooling_system, model)
1186
+ [0.936, 0.936].each_with_index do |rated_airflow_ratio, i|
1187
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_clg'][i])
1188
+ end
1066
1189
  end
1067
1190
 
1068
- def test_install_quality_mini_split_heat_pump_ratio
1191
+ def test_install_quality_mini_split_heat_pump
1069
1192
  args_hash = {}
1070
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-install-quality-mini-split-heat-pump-ducted.xml'))
1071
- model, hpxml = _test_measure(args_hash)
1193
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-install-quality-mini-split-heat-pump-ducted.xml'))
1194
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
1072
1195
 
1073
1196
  # Get HPXML values
1074
- heat_pump = hpxml.heat_pumps[0]
1075
- _check_install_quality_multispeed_ratio(heat_pump, model, heat_pump)
1197
+ heat_pump = hpxml_bldg.heat_pumps[0]
1198
+ program_values = _check_install_quality_multispeed_ratio(heat_pump, model, heat_pump)
1199
+ [0.936, 0.936].each_with_index do |rated_airflow_ratio, i|
1200
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_clg'][i], 0.01)
1201
+ end
1202
+ [0.71, 0.71].each_with_index do |rated_airflow_ratio, i|
1203
+ assert_in_epsilon(rated_airflow_ratio, program_values['FF_AF_htg'][i], 0.01)
1204
+ end
1076
1205
  end
1077
1206
 
1078
1207
  def test_custom_seasons
1079
1208
  args_hash = {}
1080
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-seasons.xml'))
1081
- model, hpxml = _test_measure(args_hash)
1209
+ args_hash['hpxml_path'] = File.absolute_path(File.join(@sample_files_path, 'base-hvac-seasons.xml'))
1210
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
1082
1211
 
1083
1212
  # Get HPXML values
1084
- hvac_control = hpxml.hvac_controls[0]
1213
+ hvac_control = hpxml_bldg.hvac_controls[0]
1085
1214
  seasons_heating_begin_month = hvac_control.seasons_heating_begin_month
1086
1215
  seasons_heating_begin_day = hvac_control.seasons_heating_begin_day
1087
1216
  seasons_heating_end_month = hvac_control.seasons_heating_end_month
@@ -1133,11 +1262,14 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
1133
1262
 
1134
1263
  def test_crankcase_heater_watts
1135
1264
  args_hash = {}
1136
- args_hash['hpxml_path'] = File.absolute_path(File.join(sample_files_dir, 'base-hvac-crankcase-heater-40w.xml'))
1137
- model, hpxml = _test_measure(args_hash)
1265
+ args_hash['hpxml_path'] = @tmp_hpxml_path
1266
+ hpxml, hpxml_bldg = _create_hpxml('base.xml')
1267
+ hpxml_bldg.cooling_systems[0].crankcase_heater_watts = 40.0
1268
+ XMLHelper.write_file(hpxml.to_doc, @tmp_hpxml_path)
1269
+ model, _hpxml, hpxml_bldg = _test_measure(args_hash)
1138
1270
 
1139
1271
  # Get HPXML values
1140
- cooling_system = hpxml.cooling_systems[0]
1272
+ cooling_system = hpxml_bldg.cooling_systems[0]
1141
1273
  crankcase_heater_watts = cooling_system.crankcase_heater_watts
1142
1274
 
1143
1275
  # Check cooling coil
@@ -1180,7 +1312,7 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
1180
1312
 
1181
1313
  File.delete(File.join(File.dirname(__FILE__), 'in.xml'))
1182
1314
 
1183
- return model, hpxml
1315
+ return model, hpxml, hpxml.buildings[0]
1184
1316
  end
1185
1317
 
1186
1318
  def _check_install_quality_multispeed_ratio(hpxml_clg_sys, model, hpxml_htg_sys = nil)
@@ -1227,5 +1359,12 @@ class HPXMLtoOpenStudioHVACTest < MiniTest::Test
1227
1359
  htg_speed_cfms = htg_ratios.map { |ratio| heating_cfm * ratio }
1228
1360
  assert_in_epsilon(program_values['FF_AF_htg'].sum, htg_speed_cfms.zip(rated_airflow_cfm_htg).map { |cfm, rated_cfm| cfm / rated_cfm }.sum, 0.01)
1229
1361
  end
1362
+
1363
+ return program_values
1364
+ end
1365
+
1366
+ def _create_hpxml(hpxml_name)
1367
+ hpxml = HPXML.new(hpxml_path: File.join(@sample_files_path, hpxml_name))
1368
+ return hpxml, hpxml.buildings[0]
1230
1369
  end
1231
1370
  end