urbanopt-cli 0.10.0 → 0.11.0
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.github/release.yml +24 -0
- data/.github/workflows/nightly_ci_build.yml +39 -29
- data/.gitignore +1 -0
- data/CHANGELOG.md +17 -0
- data/CMakeLists.txt +7 -7
- data/FindOpenStudioSDK.cmake +8 -8
- data/LICENSE.md +8 -35
- data/README.md +25 -10
- data/example_files/Gemfile +9 -9
- data/example_files/example_project_combined.json +6 -2
- data/example_files/example_project_with_ghe.json +859 -0
- data/example_files/mappers/Baseline.rb +39 -415
- data/example_files/mappers/ChilledWaterStorage.rb +1 -1
- data/example_files/mappers/CreateBar.rb +1 -1
- data/example_files/mappers/EvCharging.rb +1 -1
- data/example_files/mappers/FlexibleHotWater.rb +1 -1
- data/example_files/mappers/Floorspace.rb +1 -1
- data/example_files/mappers/HighEfficiency.rb +1 -1
- data/example_files/mappers/HighEfficiencyCreateBar.rb +1 -1
- data/example_files/mappers/HighEfficiencyFloorspace.rb +1 -1
- data/example_files/mappers/PeakHoursMelsShedding.rb +1 -1
- data/example_files/mappers/PeakHoursThermostatAdjust.rb +1 -1
- data/example_files/mappers/ThermalStorage.rb +1 -1
- data/example_files/mappers/base_workflow.osw +11 -4
- data/example_files/mappers/residential/template/util.rb +138 -0
- data/example_files/mappers/residential/util.rb +276 -0
- data/example_files/measures/BuildResidentialModel/measure.rb +118 -230
- data/example_files/measures/BuildResidentialModel/measure.xml +344 -233
- data/example_files/measures/BuildResidentialModel/resources/geometry.rb +7 -2
- data/example_files/measures/BuildResidentialModel/resources/unit_conversions.rb +5 -0
- data/example_files/measures/BuildResidentialModel/resources/util.rb +5 -0
- data/example_files/measures/BuildResidentialModel/tests/test_build_residential_model.rb +344 -0
- data/example_files/measures/BuildResidentialModel/tests/xml_building/17/feature1.xml +2112 -0
- data/example_files/measures/BuildResidentialModel/tests/xml_building/17/feature2.xml +2112 -0
- data/example_files/osm_building/7.osm +0 -2
- data/example_files/osm_building/8.osm +0 -2
- data/example_files/osm_building/9.osm +0 -2
- data/example_files/python_deps/dependencies.json +4 -3
- data/example_files/resources/hpxml-measures/.gitattributes +3 -0
- data/example_files/resources/hpxml-measures/.github/pull_request_template.md +2 -2
- data/example_files/resources/hpxml-measures/.github/workflows/add_to_project.yml +17 -0
- data/example_files/resources/hpxml-measures/.github/workflows/config.yml +37 -8
- data/example_files/resources/hpxml-measures/.gitignore +1 -0
- data/example_files/resources/hpxml-measures/.readthedocs.yml +6 -2
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/README.md +5596 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/README.md.erb +41 -0
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.rb +1324 -1035
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/measure.xml +325 -236
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/resources/geometry.rb +119 -152
- data/example_files/resources/hpxml-measures/BuildResidentialHPXML/tests/{build_residential_hpxml_test.rb → test_build_residential_hpxml.rb} +225 -107
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/README.md +96 -0
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/README.md.erb +41 -0
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/measure.rb +73 -31
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/measure.xml +60 -40
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/README.md +48 -23
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/constants.rb +5 -0
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/resources/schedules.rb +6 -12
- data/example_files/resources/hpxml-measures/BuildResidentialScheduleFile/tests/{build_residential_schedule_file_test.rb → test_build_residential_schedule_file.rb} +162 -35
- data/example_files/resources/hpxml-measures/Changelog.md +57 -1
- data/example_files/resources/hpxml-measures/Gemfile +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/README.md +83 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/README.md.erb +41 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.rb +1081 -878
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/measure.xml +258 -204
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/airflow.rb +205 -178
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/battery.rb +43 -18
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constants.rb +37 -112
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/constructions.rb +34 -73
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/data/Xing_okstate_0664D_13659_Table_A-3.csv +4165 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/data/unavailable_periods.csv +2 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/energyplus.rb +5 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/generator.rb +13 -7
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/geometry.rb +95 -42
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hotwater_appliances.rb +132 -108
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml.rb +1695 -1267
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_defaults.rb +668 -589
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schema/HPXML.xsd +304 -553
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hpxml_schematron/EPvalidator.xml +197 -112
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac.rb +1140 -1745
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/hvac_sizing.rb +412 -325
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/lighting.rb +56 -48
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/location.rb +49 -38
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/materials.rb +5 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/meta_measure.rb +17 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/minitest_helper.rb +5 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/misc_loads.rb +94 -78
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/output.rb +60 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/psychrometrics.rb +6 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/pv.rb +11 -5
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-non-stochastic.csv +1 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic-30-mins.csv +52561 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_2.csv +8761 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_3.csv +8761 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_4.csv +8761 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_5.csv +8761 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedule_files/occupancy-stochastic_6.csv +8761 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/schedules.rb +129 -137
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/simcontrols.rb +12 -21
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/unit_conversions.rb +5 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/util.rb +7 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/utility_bills.rb +6 -1
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/version.rb +7 -2
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/waterheater.rb +179 -144
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/weather.rb +129 -71
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlhelper.rb +5 -0
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/resources/xmlvalidator.rb +23 -6
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_airflow.rb +129 -118
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_battery.rb +25 -20
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_defaults.rb +2282 -2239
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_enclosure.rb +395 -204
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_generator.rb +12 -7
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hotwater_appliance.rb +56 -51
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac.rb +369 -230
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_hvac_sizing.rb +371 -191
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_lighting.rb +27 -20
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_location.rb +55 -5
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_miscloads.rb +35 -30
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_pv.rb +13 -8
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_schedules.rb +107 -93
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_simcontrols.rb +11 -6
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_validation.rb +757 -573
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_water_heater.rb +77 -72
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/test_weather.rb +36 -6
- data/example_files/resources/hpxml-measures/HPXMLtoOpenStudio/tests/util.rb +5 -0
- data/example_files/resources/hpxml-measures/README.md +2 -0
- data/example_files/resources/hpxml-measures/Rakefile +10 -3
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/README.md +787 -0
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/README.md.erb +41 -0
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/measure.rb +730 -418
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/measure.xml +1215 -9
- data/example_files/resources/hpxml-measures/ReportSimulationOutput/tests/{output_report_test.rb → test_report_sim_output.rb} +130 -299
- data/example_files/resources/hpxml-measures/ReportUtilityBills/README.md +87 -0
- data/example_files/resources/hpxml-measures/ReportUtilityBills/README.md.erb +41 -0
- data/example_files/resources/hpxml-measures/ReportUtilityBills/measure.rb +261 -89
- data/example_files/resources/hpxml-measures/ReportUtilityBills/measure.xml +179 -94
- data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/Average_retail_price_of_electricity.csv +68 -68
- data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/NG_PRI_SUM_A_EPG0_PRS_DMCF_A.csv +3 -2
- data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/PET_PRI_WFR_A_EPD2F_PRS_DPGAL_W.csv +713 -685
- data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/PET_PRI_WFR_A_EPLLPA_PRS_DPGAL_W.csv +716 -688
- data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/simple_rates/README.md +5 -2
- data/example_files/resources/hpxml-measures/ReportUtilityBills/resources/util.rb +18 -9
- data/example_files/resources/hpxml-measures/ReportUtilityBills/tests/test_report_utility_bills.rb +1308 -0
- data/example_files/resources/hpxml-measures/docs/requirements.txt +5 -0
- data/example_files/resources/hpxml-measures/docs/source/conf.py +1 -2
- data/example_files/resources/hpxml-measures/docs/source/intro.rst +3 -20
- data/example_files/resources/hpxml-measures/docs/source/usage_instructions.rst +1 -1
- data/example_files/resources/hpxml-measures/docs/source/workflow_inputs.rst +917 -564
- data/example_files/resources/hpxml-measures/docs/source/workflow_outputs.rst +79 -42
- data/example_files/resources/hpxml-measures/tasks.rb +2305 -2055
- data/example_files/resources/hpxml-measures/workflow/hpxml_inputs.json +270 -587
- data/example_files/resources/hpxml-measures/workflow/real_homes/house001.xml +559 -557
- data/example_files/resources/hpxml-measures/workflow/real_homes/house002.xml +522 -520
- data/example_files/resources/hpxml-measures/workflow/real_homes/house003.xml +534 -532
- data/example_files/resources/hpxml-measures/workflow/real_homes/house004.xml +547 -545
- data/example_files/resources/hpxml-measures/workflow/real_homes/house005.xml +546 -544
- data/example_files/resources/hpxml-measures/workflow/real_homes/house006.xml +603 -623
- data/example_files/resources/hpxml-measures/workflow/real_homes/house007.xml +613 -633
- data/example_files/resources/hpxml-measures/workflow/real_homes/house008.xml +699 -721
- data/example_files/resources/hpxml-measures/workflow/real_homes/house009.xml +662 -661
- data/example_files/resources/hpxml-measures/workflow/real_homes/house010.xml +657 -677
- data/example_files/resources/hpxml-measures/workflow/real_homes/house011.xml +470 -467
- data/example_files/resources/hpxml-measures/workflow/real_homes/house012.xml +441 -438
- data/example_files/resources/hpxml-measures/workflow/real_homes/house013.xml +468 -465
- data/example_files/resources/hpxml-measures/workflow/real_homes/house014.xml +469 -466
- data/example_files/resources/hpxml-measures/workflow/real_homes/house015.xml +468 -465
- data/example_files/resources/hpxml-measures/workflow/real_homes/house016.xml +717 -714
- data/example_files/resources/hpxml-measures/workflow/real_homes/house017.xml +647 -645
- data/example_files/resources/hpxml-measures/workflow/real_homes/house018.xml +569 -566
- data/example_files/resources/hpxml-measures/workflow/real_homes/house019.xml +602 -599
- data/example_files/resources/hpxml-measures/workflow/real_homes/house020.xml +630 -627
- data/example_files/resources/hpxml-measures/workflow/real_homes/house021.xml +776 -774
- data/example_files/resources/hpxml-measures/workflow/real_homes/house022.xml +670 -667
- data/example_files/resources/hpxml-measures/workflow/real_homes/house023.xml +632 -629
- data/example_files/resources/hpxml-measures/workflow/real_homes/house024.xml +731 -729
- data/example_files/resources/hpxml-measures/workflow/real_homes/house025.xml +672 -669
- data/example_files/resources/hpxml-measures/workflow/real_homes/house026.xml +667 -644
- data/example_files/resources/hpxml-measures/workflow/real_homes/house027.xml +646 -644
- data/example_files/resources/hpxml-measures/workflow/real_homes/house028.xml +690 -688
- data/example_files/resources/hpxml-measures/workflow/real_homes/house029.xml +701 -699
- data/example_files/resources/hpxml-measures/workflow/real_homes/house030.xml +637 -615
- data/example_files/resources/hpxml-measures/workflow/real_homes/house031.xml +690 -688
- data/example_files/resources/hpxml-measures/workflow/real_homes/house032.xml +557 -554
- data/example_files/resources/hpxml-measures/workflow/real_homes/house033.xml +534 -531
- data/example_files/resources/hpxml-measures/workflow/real_homes/house034.xml +636 -635
- data/example_files/resources/hpxml-measures/workflow/real_homes/house035.xml +616 -613
- data/example_files/resources/hpxml-measures/workflow/real_homes/house036.xml +601 -598
- data/example_files/resources/hpxml-measures/workflow/real_homes/house037.xml +581 -578
- data/example_files/resources/hpxml-measures/workflow/real_homes/house038.xml +624 -622
- data/example_files/resources/hpxml-measures/workflow/real_homes/house039.xml +584 -582
- data/example_files/resources/hpxml-measures/workflow/real_homes/house040.xml +631 -629
- data/example_files/resources/hpxml-measures/workflow/real_homes/house041.xml +922 -921
- data/example_files/resources/hpxml-measures/workflow/real_homes/house042.xml +855 -853
- data/example_files/resources/hpxml-measures/workflow/real_homes/house043.xml +739 -737
- data/example_files/resources/hpxml-measures/workflow/real_homes/house044.xml +798 -796
- data/example_files/resources/hpxml-measures/workflow/real_homes/house045.xml +696 -694
- data/example_files/resources/hpxml-measures/workflow/real_homes/house046.xml +487 -483
- data/example_files/resources/hpxml-measures/workflow/real_homes/house047.xml +443 -440
- data/example_files/resources/hpxml-measures/workflow/real_homes/house048.xml +688 -686
- data/example_files/resources/hpxml-measures/workflow/real_homes/house049.xml +722 -720
- data/example_files/resources/hpxml-measures/workflow/real_homes/house050.xml +619 -617
- data/example_files/resources/hpxml-measures/workflow/run_simulation.rb +13 -20
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-coal.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-portable.xml +11 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-ief-whole-home.xml +11 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier-multiple.xml +12 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-dehumidifier.xml +11 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-gas.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-modified.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-none.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-wood.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-cathedral.xml +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-conditioned.xml +10 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-flat.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-radiant-barrier.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-unvented-insulated-roof.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-atticroof-vented.xml +8 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-battery-scheduled.xml +571 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-battery.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-multifamily-buffer-space.xml → base-bldgtype-mf-unit-adjacent-to-multifamily-buffer-space.xml} +5 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-multiple.xml → base-bldgtype-mf-unit-adjacent-to-multiple.xml} +17 -17
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-non-freezing-space.xml → base-bldgtype-mf-unit-adjacent-to-non-freezing-space.xml} +5 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-other-heated-space.xml → base-bldgtype-mf-unit-adjacent-to-other-heated-space.xml} +5 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-adjacent-to-other-housing-unit.xml → base-bldgtype-mf-unit-adjacent-to-other-housing-unit.xml} +5 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-infil-compartmentalization-test.xml → base-bldgtype-mf-unit-infil-compartmentalization-test.xml} +461 -461
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-residents-1.xml → base-bldgtype-mf-unit-residents-1.xml} +453 -453
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-baseboard.xml → base-bldgtype-mf-unit-shared-boiler-chiller-baseboard.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-fan-coil-ducted.xml → base-bldgtype-mf-unit-shared-boiler-chiller-fan-coil-ducted.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-fan-coil.xml → base-bldgtype-mf-unit-shared-boiler-chiller-fan-coil.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-chiller-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-boiler-chiller-water-loop-heat-pump.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-cooling-tower-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-boiler-cooling-tower-water-loop-heat-pump.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-baseboard.xml → base-bldgtype-mf-unit-shared-boiler-only-baseboard.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-fan-coil-ducted.xml → base-bldgtype-mf-unit-shared-boiler-only-fan-coil-ducted.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-fan-coil-eae.xml → base-bldgtype-mf-unit-shared-boiler-only-fan-coil-eae.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-bldgtype-mf-unit-shared-boiler-only-fan-coil-fireplace-elec.xml +433 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-fan-coil.xml → base-bldgtype-mf-unit-shared-boiler-only-fan-coil.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-boiler-only-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-boiler-only-water-loop-heat-pump.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-baseboard.xml → base-bldgtype-mf-unit-shared-chiller-only-baseboard.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-fan-coil-ducted.xml → base-bldgtype-mf-unit-shared-chiller-only-fan-coil-ducted.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-fan-coil.xml → base-bldgtype-mf-unit-shared-chiller-only-fan-coil.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-chiller-only-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-chiller-only-water-loop-heat-pump.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-cooling-tower-only-water-loop-heat-pump.xml → base-bldgtype-mf-unit-shared-cooling-tower-only-water-loop-heat-pump.xml} +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-generator.xml → base-bldgtype-mf-unit-shared-generator.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-ground-loop-ground-to-air-heat-pump.xml → base-bldgtype-mf-unit-shared-ground-loop-ground-to-air-heat-pump.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-laundry-room-multiple-water-heaters.xml → base-bldgtype-mf-unit-shared-laundry-room-multiple-water-heaters.xml} +480 -480
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-laundry-room.xml → base-bldgtype-mf-unit-shared-laundry-room.xml} +10 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-mechvent-multiple.xml → base-bldgtype-mf-unit-shared-mechvent-multiple.xml} +15 -15
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-mechvent-preconditioning.xml → base-bldgtype-mf-unit-shared-mechvent-preconditioning.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-mechvent.xml → base-bldgtype-mf-unit-shared-mechvent.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-pv.xml → base-bldgtype-mf-unit-shared-pv.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-water-heater-recirc.xml → base-bldgtype-mf-unit-shared-water-heater-recirc.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily-shared-water-heater.xml → base-bldgtype-mf-unit-shared-water-heater.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-multifamily.xml → base-bldgtype-mf-unit.xml} +13 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached-2stories.xml → base-bldgtype-sfa-unit-2stories.xml} +610 -610
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached-atticroof-cathedral.xml → base-bldgtype-sfa-unit-atticroof-cathedral.xml} +558 -558
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached-infil-compartmentalization-test.xml → base-bldgtype-sfa-unit-infil-compartmentalization-test.xml} +610 -610
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-bldgtype-attached.xml → base-bldgtype-sfa-unit.xml} +610 -610
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless-outside.xml +8 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-combi-tankless.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-2-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-gshp.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-hpwh.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-tankless.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater-var-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-desuperheater.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-dwhr.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-detailed-setpoints.xml +507 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-dse.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-outside.xml +8 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-standbyloss.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect-with-solar-fraction.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-indirect.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-electric.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-gas.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-hpwh.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-jacket-indirect.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-low-flow-fixtures.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-multiple.xml +14 -14
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-none.xml +5 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-demand.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-manual.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-nocontrol.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-temperature.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-recirc-timer.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-evacuated-tube.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-flat-plate.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-direct-ics.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-fraction.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-indirect-flat-plate.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-solar-thermosyphon-flat-plate.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-coal.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-detailed-setpoints.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-elec-uef.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-outside.xml +8 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef-fhr.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas-uef.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-gas.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-detailed-schedules.xml +13 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-operating-mode-heat-pump-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-outside.xml +8 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-uef.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar-fraction.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump-with-solar.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-heat-pump.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-model-type-stratified-detailed-occupancy-stochastic.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-model-type-stratified.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-oil.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tank-wood.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-detailed-setpoints.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-outside.xml +8 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric-uef.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-electric.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-uef.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar-fraction.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas-with-solar.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-gas.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-dhw-tankless-propane.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories-garage.xml +13 -14
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-2stories.xml +11 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-1.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-2.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-4.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-beds-5.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-ceilingtypes.xml +576 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-floortypes.xml +519 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-garage.xml +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ach-house-pressure.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm-house-pressure.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-cfm50.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-ela.xml +548 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-flue.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-ach.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-infil-natural-cfm.xml +551 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-orientations.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-overhangs.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-rooftypes.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-physical-properties.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-shading.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights-storms.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-skylights.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-split-level.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-thermal-mass.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-walltypes.xml +19 -19
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-natural-ventilation-availability.xml +555 -553
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-none.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-physical-properties.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-shading-seasons.xml +560 -558
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-shading.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-enclosure-windows-storms.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-ambient.xml +10 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-basement-garage.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-belly-wing-no-skirt.xml +496 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-belly-wing-skirt.xml +496 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-complex.xml +18 -18
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-schedules-simple-power-outage-natvent-unavailable.xml → base-foundation-conditioned-basement-slab-insulation-full.xml} +552 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-slab-insulation.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-basement-wall-insulation.xml +555 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-conditioned-crawlspace.xml +8 -8
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-multiple.xml +5 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-slab.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-above-grade.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-assembly-r.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement-wall-insulation.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unconditioned-basement.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-unvented-crawlspace.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace-above-grade.xml +558 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-vented-crawlspace.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-foundation-walkout-basement.xml +15 -15
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-cooling-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-heating-capacity-17f.xml +552 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-heating-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-lockout-temperatures.xml +562 -562
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed-seer2-hspf2.xml +557 -557
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-1-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-2-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler-hvac-seasons.xml +586 -586
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler-switchover-temperature.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-boiler.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed-backup-furnace.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-acca.xml → base-hvac-air-to-air-heat-pump-var-speed-detailed-performance-other-temperatures.xml} +89 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-hers.xml → base-hvac-air-to-air-heat-pump-var-speed-detailed-performance.xml} +107 -13
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-air-to-air-heat-pump-var-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-sizing-controls.xml +567 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-coal-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-elec-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-central-ac-1-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only-pilot.xml +512 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-gas-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-oil-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-propane-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-boiler-wood-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed-seer2.xml +536 -536
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-1-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-2-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-central-ac-only-var-speed.xml → base-hvac-central-ac-only-var-speed-detailed-performance.xml} +49 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-only-var-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-central-ac-plus-air-to-air-heat-pump-heating.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dse.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed-lockout-temperatures.xml +559 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-1-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-2-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-air-to-air-heat-pump-var-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-dual-fuel-mini-split-heat-pump-ducted.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-area-fractions.xml +11 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-area-multipliers.xml +558 -558
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-buried.xml +554 -554
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-furnace-gas-room-ac.xml → base-hvac-ducts-defaults.xml} +28 -14
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-effective-rvalue.xml +552 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-cfm50.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ducts-leakage-percent.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-elec-resistance-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-furnace-gas.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only-ducted.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-evap-cooler-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-fireplace-wood-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only.xml +15 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-coal-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-central-ac-1-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-elec-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-2-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-central-ac-var-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only-detailed-setpoints.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only-pilot.xml +541 -541
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-gas-room-ac.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-oil-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-propane-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-wood-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-furnace-x3-dse.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-cooling-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump-heating-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ground-to-air-heat-pump.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-1-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-2-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-air-to-air-heat-pump-1-speed-autosized-backup.xml → base-hvac-install-quality-air-to-air-heat-pump-var-speed-detailed-performance.xml} +650 -556
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-air-to-air-heat-pump-var-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-1-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-2-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-central-ac-var-speed.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-furnace-gas-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-ground-to-air-heat-pump.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-mini-split-air-conditioner-only-ducted.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-install-quality-mini-split-heat-pump-ducted.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ducted.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-mini-split-air-conditioner-only-ducted.xml → base-hvac-mini-split-air-conditioner-only-ductless-detailed-performance.xml} +50 -49
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-air-conditioner-only-ductless.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-cooling-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-maxload.xml → base-hvac-mini-split-heat-pump-ducted-detailed-performance.xml} +109 -14
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted-heating-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ducted.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-baseboard.xml +524 -524
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted-backup-hardsized.xml → base-hvac-mini-split-heat-pump-ductless-backup-furnace-ducts-defaults.xml} +560 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-furnace.xml +563 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-backup-stove.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-autosize-dual-fuel-mini-split-heat-pump-ducted.xml → base-hvac-mini-split-heat-pump-ductless-detailed-performance.xml} +108 -60
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless-heating-capacity-17f.xml +505 -505
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-mini-split-heat-pump-ductless.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-multiple.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-none.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac-with-heating-electricity.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac-with-heating-natural-gas.xml +504 -504
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-ptac.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-pthp-heating-capacity-17f.xml +512 -512
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-pthp.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-33percent.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-ceer.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only-detailed-setpoints.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-with-heating.xml +504 -504
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-room-ac-with-reverse-cycle.xml +517 -517
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-seasons.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints-daily-schedules.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints-daily-setbacks.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-setpoints.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-fixed-heater-gas-only.xml → base-hvac-space-heater-gas-only.xml} +10 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-oil-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-stove-wood-pellets-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-wall-furnace-elec-only.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-ceiling-fans.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-holiday.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-kwh-per-year.xml +531 -528
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-mixed.xml +536 -536
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none-ceiling-fans.xml +515 -515
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-lighting-none.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-AMY-2012.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-baltimore-md.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-capetown-zaf.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-dallas-tx.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-duluth-mn.xml +4 -4
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-helena-mt.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-honolulu-hi.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-miami-fl.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-phoenix-az.xml +10 -11
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-location-portland-or.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-balanced.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-bath-kitchen-fans.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-airflow-fraction-zero.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-dse.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-evap-cooler-only-ducted.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-supplemental-fan-exhaust.xml +576 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis-supplemental-fan-supply.xml +576 -576
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-cfis.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv-atre-asre.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-erv.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust-rated-flow-rate.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-exhaust.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv-asre.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-hrv.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-multiple.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-supply.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-mechvent-whole-house-fan.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-additional-properties.xml +21 -19
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv-detailed-only.xml +605 -605
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv-mixed.xml +587 -587
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-pv.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-defaults.xml +3 -3
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-emissions.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators-battery-scheduled.xml +587 -585
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators-battery.xml +584 -584
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-generators.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-ground-conductivity.xml +555 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon.xml +26 -26
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-large-uncommon2.xml +26 -26
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-loads-none.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading-bldgtype-multifamily.xml +508 -508
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-neighbor-shading.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-shielding-of-home.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-schedules-simple-power-outage-natvent-available.xml → base-misc-unit-multiplier.xml} +553 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-usage-multiplier.xml +26 -26
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-multiple-mf-units.xml +2755 -0
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-multiple-buildings.xml → base-multiple-sfd-buildings.xml} +31 -22
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-ah.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-garage.xml +4 -5
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-round-trip-efficiency.xml +597 -597
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery-scheduled.xml +599 -597
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-battery.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators-battery-scheduled.xml +615 -613
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators-battery.xml +612 -612
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv-generators.xml +596 -596
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-pv.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-0-runperiod-1-month.xml +559 -559
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-0.xml +555 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-1-misc-loads-large-uncommon.xml +616 -616
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-1-misc-loads-large-uncommon2.xml +616 -616
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-1.xml +547 -547
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-residents-5.xml +515 -515
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-all-10-mins.xml +14 -12
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-hvac-crankcase-heater-40w.xml → base-schedules-detailed-mixed-timesteps-power-outage.xml} +565 -555
- data/example_files/resources/hpxml-measures/workflow/sample_files/{base-schedules-detailed-occupancy-stochastic-vacancy-year-round.xml → base-schedules-detailed-mixed-timesteps.xml} +554 -563
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-10-mins.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-power-outage.xml +566 -564
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic-vacancy.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-occupancy-stochastic.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints-daily-schedules.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints-daily-setbacks.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-detailed-setpoints.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-power-outage.xml +619 -619
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-vacancy.xml +618 -618
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-calendar-year-custom.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-custom.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-daylight-saving-disabled.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-runperiod-1-month.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-temperature-capacitance-multiplier.xml +553 -553
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins-occupancy-stochastic-10-mins.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins-occupancy-stochastic-60-mins.xml +12 -10
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-10-mins.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-simcontrol-timestep-30-mins.xml +552 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base.xml +9 -9
- data/example_files/resources/hpxml-measures/workflow/template-build-and-run-hpxml-with-stochastic-occupancy.osw +2 -0
- data/example_files/resources/hpxml-measures/workflow/template-run-hpxml-with-stochastic-occupancy-subset.osw +2 -0
- data/example_files/resources/hpxml-measures/workflow/template-run-hpxml-with-stochastic-occupancy.osw +2 -0
- data/example_files/resources/hpxml-measures/workflow/template-run-hpxml.osw +4 -1
- data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Long_Residence.xml +385 -385
- data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Vatilo_Residence.xml +378 -380
- data/example_files/resources/hpxml-measures/workflow/tests/ACCA_Examples/Victor_Residence.xml +369 -369
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L100AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L110AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L120AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L130AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L140AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L150AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L155AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L160AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L170AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L200AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AC.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L202AL.xml +7 -7
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L302XC.xml +7 -8
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L304XC.xml +7 -8
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L322XC.xml +6 -6
- data/example_files/resources/hpxml-measures/workflow/tests/ASHRAE_Standard_140/L324XC.xml +6 -6
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_sizing.csv +363 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations1.csv +281 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations1_bills.csv +281 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations2.csv +141 -0
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_workflow_simulations2_bills.csv +141 -0
- data/example_files/resources/hpxml-measures/workflow/tests/compare.py +12 -6
- data/example_files/resources/hpxml-measures/workflow/tests/util.rb +1141 -0
- data/example_files/weather/USA_CO_Denver.Intl.AP.725650_TMY3.ddy +536 -0
- data/example_files/weather/USA_CO_Denver.Intl.AP.725650_TMY3.epw +8768 -0
- data/example_files/weather/USA_CO_Denver.Intl.AP.725650_TMY3.stat +554 -0
- data/example_files/weather/USA_FL_MacDill.AFB.747880_TMY3.ddy +536 -0
- data/example_files/weather/USA_FL_MacDill.AFB.747880_TMY3.epw +8768 -0
- data/example_files/weather/USA_FL_MacDill.AFB.747880_TMY3.stat +553 -0
- data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3-cache.csv +35 -0
- data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3.ddy +536 -0
- data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3.epw +8768 -0
- data/example_files/weather/USA_GA_Atlanta-Hartsfield-Jackson.Intl.AP.722190_TMY3.stat +553 -0
- data/example_files/weather/USA_NY_Buffalo-Greater.Buffalo.Intl.AP.725280_TMY3-cache.csv +35 -0
- data/example_files/xml_building/17/README.md +4 -2
- data/example_files/xml_building/17/feature.xml +2112 -0
- data/lib/uo_cli/version.rb +1 -1
- data/lib/uo_cli.rb +110 -17
- data/uo_cli.gemspec +6 -8
- metadata +130 -177
- data/Jenkinsfile +0 -10
- data/example_files/base_workflow_res.osw +0 -276
- data/example_files/resources/hpxml-measures/ReportUtilityBills/tests/utility_bills_test.rb +0 -1226
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-oil-location-miami-fl.xml +0 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-appliances-propane-location-portland-or.xml +0 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-cooling-only.xml +0 -544
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-heating-only.xml +0 -550
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-acca.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-hers.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-maxload-miami-fl.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-1-speed-sizing-methodology-maxload.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-acca.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-hers.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-2-speed-sizing-methodology-maxload.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-backup-boiler.xml +0 -569
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-backup-furnace.xml +0 -599
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-air-to-air-heat-pump-var-speed-sizing-methodology-maxload.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-elec-only.xml +0 -506
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-gas-central-ac-1-speed.xml +0 -560
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-boiler-gas-only.xml +0 -507
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-only-1-speed.xml +0 -536
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-only-2-speed.xml +0 -536
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-central-ac-plus-air-to-air-heat-pump-heating.xml +0 -565
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-acca.xml +0 -553
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-hers.xml +0 -553
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-dual-fuel-air-to-air-heat-pump-1-speed-sizing-methodology-maxload.xml +0 -553
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-elec-resistance-only.xml +0 -497
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-evap-cooler-furnace-gas.xml +0 -544
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-floor-furnace-propane-only.xml +0 -500
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-elec-only.xml +0 -536
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-central-ac-2-speed.xml +0 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-central-ac-var-speed.xml +0 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-furnace-gas-only.xml +0 -536
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-cooling-only.xml +0 -546
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-heating-only.xml +0 -552
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-acca.xml +0 -554
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-hers.xml +0 -554
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ground-to-air-heat-pump-sizing-methodology-maxload.xml +0 -554
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-cooling-only.xml +0 -543
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-heating-only.xml +0 -549
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-acca.xml +0 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ducted-sizing-methodology-hers.xml +0 -551
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ductless-backup-baseboard.xml +0 -519
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-mini-split-heat-pump-ductless-backup-stove.xml +0 -522
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ptac-with-heating.xml +0 -503
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-ptac.xml +0 -496
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-acca.xml +0 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-hers.xml +0 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-pthp-sizing-methodology-maxload.xml +0 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-only.xml +0 -496
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-heating.xml +0 -503
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-acca.xml +0 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-hers.xml +0 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-room-ac-with-reverse-cycle-sizing-methodology-maxload.xml +0 -518
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-stove-oil-only.xml +0 -500
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-autosize-wall-furnace-elec-only.xml +0 -500
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-floor-furnace-propane-only-pilot-light.xml +0 -506
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-portable-heater-gas-only.xml +0 -501
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-hvac-undersized-allow-increased-fixed-capacities.xml +0 -556
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-misc-bills-none.xml +0 -548
- data/example_files/resources/hpxml-measures/workflow/sample_files/base-schedules-simple-vacancy-year-round.xml +0 -619
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results.csv +0 -475
- data/example_files/resources/hpxml-measures/workflow/tests/base_results/results_bills.csv +0 -475
- data/example_files/resources/hpxml-measures/workflow/tests/hpxml_translator_test.rb +0 -1313
- data/example_files/resources/measure-info.json +0 -26
- data/example_files/resources/meta_measure.rb +0 -301
- data/example_files/xml_building/17/unit 1.xml +0 -580
- data/example_files/xml_building/17/unit 2.xml +0 -553
- data/example_files/xml_building/17/unit 3.xml +0 -553
- data/example_files/xml_building/17/unit 4.xml +0 -580
- /data/example_files/{residential → mappers/residential/template/iecc}/clothes_dryer.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/clothes_washer.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/cooling_system.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/dishwasher.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/enclosure.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/heat_pump.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/heating_system.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/mechanical_ventilation.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/refrigerator.tsv +0 -0
- /data/example_files/{residential → mappers/residential/template/iecc}/water_heater.tsv +0 -0
- /data/example_files/resources/hpxml-measures/ReportUtilityBills/tests/{JacksonElectricMemberCorp-ResidentialSeniorCitizenLowIncomeAssistance.json → Detailed Rate.json} +0 -0
@@ -1,10 +1,15 @@
|
|
1
|
+
# *********************************************************************************
|
2
|
+
# URBANopt (tm), Copyright (c) Alliance for Sustainable Energy, LLC.
|
3
|
+
# See also https://github.com/urbanopt/urbanopt-cli/blob/develop/LICENSE.md
|
4
|
+
# *********************************************************************************
|
5
|
+
|
1
6
|
# frozen_string_literal: true
|
2
7
|
|
3
8
|
class Airflow
|
4
9
|
# Constants
|
5
10
|
InfilPressureExponent = 0.65
|
6
11
|
|
7
|
-
def self.apply(model, runner, weather, spaces,
|
12
|
+
def self.apply(model, runner, weather, spaces, hpxml_header, hpxml_bldg, cfa, nbeds,
|
8
13
|
ncfl_ag, duct_systems, airloop_map, clg_ssn_sensor, eri_version,
|
9
14
|
frac_windows_operable, apply_ashrae140_assumptions, schedules_file,
|
10
15
|
unavailable_periods, hvac_availability_sensor)
|
@@ -13,16 +18,16 @@ class Airflow
|
|
13
18
|
|
14
19
|
@runner = runner
|
15
20
|
@spaces = spaces
|
16
|
-
@year =
|
17
|
-
@
|
18
|
-
@
|
21
|
+
@year = hpxml_header.sim_calendar_year
|
22
|
+
@conditioned_space = spaces[HPXML::LocationConditionedSpace]
|
23
|
+
@conditioned_zone = @conditioned_space.thermalZone.get
|
19
24
|
@nbeds = nbeds
|
20
25
|
@ncfl_ag = ncfl_ag
|
21
26
|
@eri_version = eri_version
|
22
27
|
@apply_ashrae140_assumptions = apply_ashrae140_assumptions
|
23
28
|
@cfa = cfa
|
24
|
-
@cooking_range_in_cond_space =
|
25
|
-
@clothes_dryer_in_cond_space =
|
29
|
+
@cooking_range_in_cond_space = hpxml_bldg.cooking_ranges.empty? ? true : HPXML::conditioned_locations_this_unit.include?(hpxml_bldg.cooking_ranges[0].location)
|
30
|
+
@clothes_dryer_in_cond_space = hpxml_bldg.clothes_dryers.empty? ? true : HPXML::conditioned_locations_this_unit.include?(hpxml_bldg.clothes_dryers[0].location)
|
26
31
|
@hvac_availability_sensor = hvac_availability_sensor
|
27
32
|
|
28
33
|
# Global sensors
|
@@ -34,19 +39,19 @@ class Airflow
|
|
34
39
|
@wout_sensor.setName('out wt s')
|
35
40
|
|
36
41
|
@win_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Air Humidity Ratio')
|
37
|
-
@win_sensor.setName(
|
38
|
-
@win_sensor.setKeyName(@
|
42
|
+
@win_sensor.setName('win s')
|
43
|
+
@win_sensor.setKeyName(@conditioned_zone.name.to_s)
|
39
44
|
|
40
45
|
@vwind_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Site Wind Speed')
|
41
46
|
@vwind_sensor.setName('site vw s')
|
42
47
|
|
43
48
|
@tin_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Mean Air Temperature')
|
44
|
-
@tin_sensor.setName(
|
45
|
-
@tin_sensor.setKeyName(@
|
49
|
+
@tin_sensor.setName('tin s')
|
50
|
+
@tin_sensor.setKeyName(@conditioned_zone.name.to_s)
|
46
51
|
|
47
52
|
@tout_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Outdoor Air Drybulb Temperature')
|
48
|
-
@tout_sensor.setName(
|
49
|
-
@tout_sensor.setKeyName(@
|
53
|
+
@tout_sensor.setName('tout s')
|
54
|
+
@tout_sensor.setKeyName(@conditioned_zone.name.to_s)
|
50
55
|
|
51
56
|
@adiabatic_const = nil
|
52
57
|
|
@@ -56,7 +61,7 @@ class Airflow
|
|
56
61
|
vent_fans_bath = []
|
57
62
|
vent_fans_whf = []
|
58
63
|
vent_fans_cfis_suppl = []
|
59
|
-
|
64
|
+
hpxml_bldg.ventilation_fans.each do |vent_fan|
|
60
65
|
next unless vent_fan.hours_in_operation.nil? || vent_fan.hours_in_operation > 0
|
61
66
|
|
62
67
|
if vent_fan.used_for_whole_building_ventilation
|
@@ -77,7 +82,7 @@ class Airflow
|
|
77
82
|
end
|
78
83
|
|
79
84
|
# Vented clothes dryers
|
80
|
-
vented_dryers =
|
85
|
+
vented_dryers = hpxml_bldg.clothes_dryers.select { |cd| cd.is_vented && cd.vented_flow_rate.to_f > 0 }
|
81
86
|
|
82
87
|
# Initialization
|
83
88
|
initialize_cfis(model, vent_fans_mech, airloop_map, unavailable_periods)
|
@@ -91,31 +96,31 @@ class Airflow
|
|
91
96
|
# Apply ducts
|
92
97
|
|
93
98
|
duct_systems.each do |ducts, object|
|
94
|
-
apply_ducts(model, ducts, object, vent_fans_mech)
|
99
|
+
apply_ducts(model, ducts, object, vent_fans_mech, hpxml_bldg.building_construction.number_of_units)
|
95
100
|
end
|
96
101
|
|
97
102
|
# Apply infiltration/ventilation
|
98
103
|
|
99
|
-
set_wind_speed_correction(model,
|
100
|
-
window_area =
|
104
|
+
set_wind_speed_correction(model, hpxml_bldg.site)
|
105
|
+
window_area = hpxml_bldg.windows.map { |w| w.area }.sum(0.0)
|
101
106
|
open_window_area = window_area * frac_windows_operable * 0.5 * 0.2 # Assume A) 50% of the area of an operable window can be open, and B) 20% of openable window area is actually open
|
102
107
|
|
103
|
-
vented_attic =
|
104
|
-
vented_crawl =
|
108
|
+
vented_attic = hpxml_bldg.attics.find { |attic| attic.attic_type == HPXML::AtticTypeVented }
|
109
|
+
vented_crawl = hpxml_bldg.foundations.find { |foundation| foundation.foundation_type == HPXML::FoundationTypeCrawlspaceVented }
|
105
110
|
|
106
|
-
_sla,
|
111
|
+
_sla, conditioned_ach50, nach, infil_volume, infil_height, a_ext = get_values_from_air_infiltration_measurements(hpxml_bldg, cfa, weather)
|
107
112
|
if @apply_ashrae140_assumptions
|
108
|
-
|
109
|
-
|
113
|
+
conditioned_const_ach = nach
|
114
|
+
conditioned_ach50 = nil
|
110
115
|
end
|
111
|
-
|
112
|
-
|
113
|
-
has_flue_chimney_in_cond_space =
|
116
|
+
conditioned_const_ach *= a_ext unless conditioned_const_ach.nil?
|
117
|
+
conditioned_ach50 *= a_ext unless conditioned_ach50.nil?
|
118
|
+
has_flue_chimney_in_cond_space = hpxml_bldg.air_infiltration.has_flue_or_chimney_in_conditioned_space
|
114
119
|
|
115
|
-
apply_natural_ventilation_and_whole_house_fan(model,
|
120
|
+
apply_natural_ventilation_and_whole_house_fan(model, hpxml_bldg.site, vent_fans_whf, open_window_area, clg_ssn_sensor, hpxml_bldg.header.natvent_days_per_week,
|
116
121
|
infil_volume, infil_height, unavailable_periods)
|
117
|
-
apply_infiltration_and_ventilation_fans(model, weather,
|
118
|
-
has_flue_chimney_in_cond_space,
|
122
|
+
apply_infiltration_and_ventilation_fans(model, weather, hpxml_bldg.site, vent_fans_mech, vent_fans_kitchen, vent_fans_bath, vented_dryers,
|
123
|
+
has_flue_chimney_in_cond_space, conditioned_ach50, conditioned_const_ach, infil_volume, infil_height,
|
119
124
|
vented_attic, vented_crawl, clg_ssn_sensor, schedules_file, vent_fans_cfis_suppl, unavailable_periods)
|
120
125
|
end
|
121
126
|
|
@@ -171,13 +176,13 @@ class Airflow
|
|
171
176
|
fail 'Unexpected error.'
|
172
177
|
end
|
173
178
|
|
174
|
-
def self.get_values_from_air_infiltration_measurements(
|
175
|
-
measurement = get_infiltration_measurement_of_interest(
|
179
|
+
def self.get_values_from_air_infiltration_measurements(hpxml_bldg, cfa, weather)
|
180
|
+
measurement = get_infiltration_measurement_of_interest(hpxml_bldg.air_infiltration_measurements)
|
176
181
|
|
177
182
|
volume = measurement.infiltration_volume
|
178
183
|
height = measurement.infiltration_height
|
179
184
|
if height.nil?
|
180
|
-
height =
|
185
|
+
height = hpxml_bldg.inferred_infiltration_height(volume)
|
181
186
|
end
|
182
187
|
|
183
188
|
sla, ach50, nach = nil
|
@@ -214,9 +219,9 @@ class Airflow
|
|
214
219
|
return sla, ach50, nach, volume, height, a_ext
|
215
220
|
end
|
216
221
|
|
217
|
-
def self.get_default_mech_vent_flow_rate(
|
222
|
+
def self.get_default_mech_vent_flow_rate(hpxml_bldg, vent_fan, weather, cfa, nbeds)
|
218
223
|
# Calculates Qfan cfm requirement per ASHRAE 62.2-2019
|
219
|
-
sla, _ach50, _nach, _volume, height, a_ext = get_values_from_air_infiltration_measurements(
|
224
|
+
sla, _ach50, _nach, _volume, height, a_ext = get_values_from_air_infiltration_measurements(hpxml_bldg, cfa, weather)
|
220
225
|
|
221
226
|
nl = get_infiltration_NL_from_SLA(sla, height)
|
222
227
|
q_inf = nl * weather.data.WSF * cfa / 7.3 # Effective annual average infiltration rate, cfm, eq. 4.5a
|
@@ -341,8 +346,8 @@ class Airflow
|
|
341
346
|
end
|
342
347
|
|
343
348
|
# Sensors
|
344
|
-
if @
|
345
|
-
thermostat = @
|
349
|
+
if @conditioned_zone.thermostatSetpointDualSetpoint.is_initialized
|
350
|
+
thermostat = @conditioned_zone.thermostatSetpointDualSetpoint.get
|
346
351
|
|
347
352
|
htg_sp_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Schedule Value')
|
348
353
|
htg_sp_sensor.setName('htg sp s')
|
@@ -357,23 +362,25 @@ class Airflow
|
|
357
362
|
nv_flow = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
358
363
|
nv_flow.setName(Constants.ObjectNameNaturalVentilation + ' flow')
|
359
364
|
nv_flow.setSchedule(model.alwaysOnDiscreteSchedule)
|
360
|
-
nv_flow.setSpace(@
|
365
|
+
nv_flow.setSpace(@conditioned_space)
|
361
366
|
nv_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(nv_flow, *EPlus::EMSActuatorZoneInfiltrationFlowRate)
|
362
367
|
nv_flow_actuator.setName("#{nv_flow.name} act")
|
368
|
+
nv_flow.additionalProperties.setFeature('ObjectType', Constants.ObjectNameNaturalVentilation)
|
363
369
|
|
364
370
|
whf_flow = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
365
371
|
whf_flow.setName(Constants.ObjectNameWholeHouseFan + ' flow')
|
366
372
|
whf_flow.setSchedule(model.alwaysOnDiscreteSchedule)
|
367
|
-
whf_flow.setSpace(@
|
373
|
+
whf_flow.setSpace(@conditioned_space)
|
368
374
|
whf_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(whf_flow, *EPlus::EMSActuatorZoneInfiltrationFlowRate)
|
369
375
|
whf_flow_actuator.setName("#{whf_flow.name} act")
|
376
|
+
whf_flow.additionalProperties.setFeature('ObjectType', Constants.ObjectNameWholeHouseFan)
|
370
377
|
|
371
378
|
# Electric Equipment (for whole house fan electricity consumption)
|
372
379
|
whf_equip_def = OpenStudio::Model::ElectricEquipmentDefinition.new(model)
|
373
380
|
whf_equip_def.setName(Constants.ObjectNameWholeHouseFan)
|
374
381
|
whf_equip = OpenStudio::Model::ElectricEquipment.new(whf_equip_def)
|
375
382
|
whf_equip.setName(Constants.ObjectNameWholeHouseFan)
|
376
|
-
whf_equip.setSpace(@
|
383
|
+
whf_equip.setSpace(@conditioned_space) # no heat gain, so assign the equipment to an arbitrary space
|
377
384
|
whf_equip_def.setFractionRadiant(0)
|
378
385
|
whf_equip_def.setFractionLatent(0)
|
379
386
|
whf_equip_def.setFractionLost(1)
|
@@ -390,12 +397,12 @@ class Airflow
|
|
390
397
|
whf_zone = @spaces[HPXML::LocationAtticUnvented].thermalZone.get
|
391
398
|
end
|
392
399
|
if not whf_zone.nil?
|
393
|
-
# Air from
|
400
|
+
# Air from conditioned space to WHF zone (attic)
|
394
401
|
zone_mixing = OpenStudio::Model::ZoneMixing.new(whf_zone)
|
395
402
|
zone_mixing.setName("#{Constants.ObjectNameWholeHouseFan} mix")
|
396
|
-
zone_mixing.setSourceZone(@
|
397
|
-
|
398
|
-
|
403
|
+
zone_mixing.setSourceZone(@conditioned_zone)
|
404
|
+
cond_to_zone_flow_rate_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(zone_mixing, *EPlus::EMSActuatorZoneMixingFlowRate)
|
405
|
+
cond_to_zone_flow_rate_actuator.setName("#{zone_mixing.name} act")
|
399
406
|
end
|
400
407
|
|
401
408
|
area = 0.6 * open_window_area # ft^2, for Sherman-Grimsrud
|
@@ -403,12 +410,13 @@ class Airflow
|
|
403
410
|
max_flow_rate = max_rate * infil_volume / UnitConversions.convert(1.0, 'hr', 'min')
|
404
411
|
neutral_level = 0.5
|
405
412
|
hor_lk_frac = 0.0
|
406
|
-
c_w, c_s = calc_wind_stack_coeffs(site, hor_lk_frac, neutral_level, @
|
413
|
+
c_w, c_s = calc_wind_stack_coeffs(site, hor_lk_frac, neutral_level, @conditioned_space, infil_height)
|
407
414
|
max_oa_hr = 0.0115 # From BA HSP
|
408
415
|
max_oa_rh = 0.7 # From BA HSP
|
409
416
|
|
410
417
|
# Program
|
411
418
|
vent_program = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
419
|
+
vent_program.additionalProperties.setFeature('ObjectType', Constants.ObjectNameNaturalVentilation)
|
412
420
|
vent_program.setName(Constants.ObjectNameNaturalVentilation + ' program')
|
413
421
|
vent_program.addLine("Set Tin = #{@tin_sensor.name}")
|
414
422
|
vent_program.addLine("Set Tout = #{@tout_sensor.name}")
|
@@ -430,7 +438,7 @@ class Airflow
|
|
430
438
|
vent_program.addLine("Set ClgSsnAvail = #{nv_clg_ssn_sensor.name}")
|
431
439
|
vent_program.addLine("Set #{nv_flow_actuator.name} = 0") # Init
|
432
440
|
vent_program.addLine("Set #{whf_flow_actuator.name} = 0") # Init
|
433
|
-
vent_program.addLine("Set #{
|
441
|
+
vent_program.addLine("Set #{cond_to_zone_flow_rate_actuator.name} = 0") unless whf_zone.nil? # Init
|
434
442
|
vent_program.addLine("Set #{whf_elec_actuator.name} = 0") # Init
|
435
443
|
infil_constraints = 'If ((Wout < MaxHR) && (Phiout < MaxRH) && (Tin > Tout) && (Tin > Tnvsp) && (ClgSsnAvail > 0))'
|
436
444
|
if not @hvac_availability_sensor.nil?
|
@@ -449,7 +457,7 @@ class Airflow
|
|
449
457
|
vent_program.addLine(' Set Adj = (@Max Adj 0)')
|
450
458
|
vent_program.addLine(' If (WHF_Flow > 0)') # If available, prioritize whole house fan
|
451
459
|
vent_program.addLine(" Set #{whf_flow_actuator.name} = WHF_Flow*Adj")
|
452
|
-
vent_program.addLine(" Set #{
|
460
|
+
vent_program.addLine(" Set #{cond_to_zone_flow_rate_actuator.name} = WHF_Flow*Adj") unless whf_zone.nil?
|
453
461
|
vent_program.addLine(' Set WHF_W = 0')
|
454
462
|
vent_fans_whf.each do |vent_whf|
|
455
463
|
vent_program.addLine(" Set WHF_W = WHF_W + #{vent_whf.fan_power} * #{whf_avail_sensors[vent_whf.id].name}")
|
@@ -472,6 +480,19 @@ class Airflow
|
|
472
480
|
manager.setName("#{vent_program.name} calling manager")
|
473
481
|
manager.setCallingPoint('BeginZoneTimestepAfterInitHeatBalance')
|
474
482
|
manager.addProgram(vent_program)
|
483
|
+
|
484
|
+
create_timeseries_flowrate_ems_output_var(model, nv_flow_actuator.name.to_s, vent_program)
|
485
|
+
create_timeseries_flowrate_ems_output_var(model, whf_flow_actuator.name.to_s, vent_program)
|
486
|
+
end
|
487
|
+
|
488
|
+
def self.create_timeseries_flowrate_ems_output_var(model, ems_var_name, ems_program)
|
489
|
+
# This is only used to report timeseries flow rates when requested
|
490
|
+
ems_output_var = OpenStudio::Model::EnergyManagementSystemOutputVariable.new(model, ems_var_name)
|
491
|
+
ems_output_var.setName("#{ems_var_name}_timeseries_outvar")
|
492
|
+
ems_output_var.setTypeOfDataInVariable('Averaged')
|
493
|
+
ems_output_var.setUpdateFrequency('ZoneTimestep')
|
494
|
+
ems_output_var.setEMSProgramOrSubroutineName(ems_program)
|
495
|
+
ems_output_var.setUnits('m^/s')
|
475
496
|
end
|
476
497
|
|
477
498
|
def self.create_nv_and_whf_avail_sch(model, obj_name, num_days_per_week, unavailable_periods = [])
|
@@ -499,9 +520,10 @@ class Airflow
|
|
499
520
|
return avail_sch
|
500
521
|
end
|
501
522
|
|
502
|
-
def self.create_return_air_duct_zone(model, loop_name)
|
523
|
+
def self.create_return_air_duct_zone(model, loop_name, unit_multiplier)
|
503
524
|
# Create the return air plenum zone, space
|
504
525
|
ra_duct_zone = OpenStudio::Model::ThermalZone.new(model)
|
526
|
+
ra_duct_zone.setMultiplier(unit_multiplier)
|
505
527
|
ra_duct_zone.setName(loop_name + ' ret air zone')
|
506
528
|
ra_duct_zone.setVolume(1.0)
|
507
529
|
|
@@ -539,7 +561,7 @@ class Airflow
|
|
539
561
|
return ra_duct_zone
|
540
562
|
end
|
541
563
|
|
542
|
-
def self.create_other_equipment_object_and_actuator(model:, name:, space:, frac_lat:, frac_lost:, hpxml_fuel_type: nil, end_use: nil
|
564
|
+
def self.create_other_equipment_object_and_actuator(model:, name:, space:, frac_lat:, frac_lost:, hpxml_fuel_type: nil, end_use: nil)
|
543
565
|
other_equip_def = OpenStudio::Model::OtherEquipmentDefinition.new(model)
|
544
566
|
other_equip_def.setName("#{name} equip")
|
545
567
|
other_equip = OpenStudio::Model::OtherEquipment.new(other_equip_def)
|
@@ -559,9 +581,6 @@ class Airflow
|
|
559
581
|
other_equip_def.setFractionRadiant(0.0)
|
560
582
|
actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(other_equip, *EPlus::EMSActuatorOtherEquipmentPower, other_equip.space.get)
|
561
583
|
actuator.setName("#{other_equip.name} act")
|
562
|
-
if not is_duct_load_for_report.nil?
|
563
|
-
other_equip.additionalProperties.setFeature(Constants.IsDuctLoadForReport, is_duct_load_for_report)
|
564
|
-
end
|
565
584
|
return actuator
|
566
585
|
end
|
567
586
|
|
@@ -654,7 +673,7 @@ class Airflow
|
|
654
673
|
end
|
655
674
|
end
|
656
675
|
|
657
|
-
def self.apply_ducts(model, ducts, object, vent_fans_mech)
|
676
|
+
def self.apply_ducts(model, ducts, object, vent_fans_mech, unit_multiplier)
|
658
677
|
ducts.each do |duct|
|
659
678
|
if not duct.loc_schedule.nil?
|
660
679
|
# Pass MF space temperature schedule name
|
@@ -674,16 +693,16 @@ class Airflow
|
|
674
693
|
# Most system types
|
675
694
|
|
676
695
|
# Set the return plenum
|
677
|
-
ra_duct_zone = create_return_air_duct_zone(model, object.name.to_s)
|
696
|
+
ra_duct_zone = create_return_air_duct_zone(model, object.name.to_s, unit_multiplier)
|
678
697
|
ra_duct_space = ra_duct_zone.spaces[0]
|
679
|
-
@
|
698
|
+
@conditioned_zone.setReturnPlenum(ra_duct_zone, object)
|
680
699
|
|
681
700
|
inlet_node = object.demandInletNode
|
682
701
|
elsif object.is_a? OpenStudio::Model::ZoneHVACFourPipeFanCoil
|
683
702
|
# Ducted fan coil
|
684
703
|
|
685
704
|
# No return plenum
|
686
|
-
ra_duct_space = @
|
705
|
+
ra_duct_space = @conditioned_space
|
687
706
|
|
688
707
|
inlet_node = object.inletNode.get
|
689
708
|
end
|
@@ -714,33 +733,33 @@ class Airflow
|
|
714
733
|
ah_wout_sensor.setName("#{ah_wout_var.name} s")
|
715
734
|
ah_wout_sensor.setKeyName(inlet_node.name.to_s)
|
716
735
|
|
717
|
-
|
718
|
-
@
|
736
|
+
conditioned_zone_return_air_node = nil
|
737
|
+
@conditioned_zone.returnAirModelObjects.each do |return_air_model_obj|
|
719
738
|
next if return_air_model_obj.to_Node.get.airLoopHVAC.get != object
|
720
739
|
|
721
|
-
|
740
|
+
conditioned_zone_return_air_node = return_air_model_obj
|
722
741
|
end
|
723
742
|
|
724
743
|
# Return air temperature
|
725
744
|
ra_t_var = OpenStudio::Model::EnergyManagementSystemGlobalVariable.new(model, "#{object.name} RA T".gsub(' ', '_'))
|
726
|
-
if not
|
745
|
+
if not conditioned_zone_return_air_node.nil?
|
727
746
|
ra_t_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'System Node Temperature')
|
728
747
|
ra_t_sensor.setName("#{ra_t_var.name} s")
|
729
|
-
ra_t_sensor.setKeyName(
|
748
|
+
ra_t_sensor.setKeyName(conditioned_zone_return_air_node.name.to_s)
|
730
749
|
else
|
731
750
|
ra_t_sensor = @tin_sensor
|
732
751
|
end
|
733
752
|
|
734
753
|
# Return air humidity ratio
|
735
754
|
ra_w_var = OpenStudio::Model::EnergyManagementSystemGlobalVariable.new(model, "#{object.name} Ra W".gsub(' ', '_'))
|
736
|
-
if not
|
755
|
+
if not conditioned_zone_return_air_node.nil?
|
737
756
|
ra_w_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'System Node Humidity Ratio')
|
738
757
|
ra_w_sensor.setName("#{ra_w_var.name} s")
|
739
|
-
ra_w_sensor.setKeyName(
|
758
|
+
ra_w_sensor.setKeyName(conditioned_zone_return_air_node.name.to_s)
|
740
759
|
else
|
741
760
|
ra_w_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Mean Air Humidity Ratio')
|
742
761
|
ra_w_sensor.setName("#{ra_w_var.name} s")
|
743
|
-
ra_w_sensor.setKeyName(@
|
762
|
+
ra_w_sensor.setKeyName(@conditioned_zone.name.to_s)
|
744
763
|
end
|
745
764
|
|
746
765
|
# Get duct located zone or ambient temperature schedule objects
|
@@ -748,7 +767,7 @@ class Airflow
|
|
748
767
|
|
749
768
|
# Create one duct program for each duct location zone
|
750
769
|
duct_locations.each_with_index do |duct_location, i|
|
751
|
-
next if (not duct_location.nil?) && (duct_location.name.to_s == @
|
770
|
+
next if (not duct_location.nil?) && (duct_location.name.to_s == @conditioned_zone.name.to_s)
|
752
771
|
|
753
772
|
object_name_idx = "#{object.name}_#{i}"
|
754
773
|
|
@@ -784,7 +803,7 @@ class Airflow
|
|
784
803
|
dz_w = "#{dz_w_sensor.name}"
|
785
804
|
elsif duct_location.name.to_s == HPXML::LocationOtherHousingUnit
|
786
805
|
dz_w_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Mean Air Humidity Ratio')
|
787
|
-
dz_w_sensor.setKeyName(@
|
806
|
+
dz_w_sensor.setKeyName(@conditioned_zone.name.to_s)
|
788
807
|
dz_w_sensor.setName("#{dz_w_var.name} s")
|
789
808
|
dz_w = "#{dz_w_sensor.name}"
|
790
809
|
else
|
@@ -792,7 +811,7 @@ class Airflow
|
|
792
811
|
dz_w_sensor1.setName("#{dz_w_var.name} s 1")
|
793
812
|
dz_w_sensor2 = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Mean Air Humidity Ratio')
|
794
813
|
dz_w_sensor2.setName("#{dz_w_var.name} s 2")
|
795
|
-
dz_w_sensor2.setKeyName(@
|
814
|
+
dz_w_sensor2.setKeyName(@conditioned_zone.name.to_s)
|
796
815
|
dz_w = "(#{dz_w_sensor1.name} + #{dz_w_sensor2.name}) / 2"
|
797
816
|
end
|
798
817
|
else
|
@@ -814,47 +833,47 @@ class Airflow
|
|
814
833
|
end
|
815
834
|
|
816
835
|
# Other equipment objects to cancel out the supply air leakage directly into the return plenum
|
817
|
-
equip_act_infos << ['
|
818
|
-
equip_act_infos << ['
|
836
|
+
equip_act_infos << ['supply_sens_lk_to_cond', 'SupSensLkToCond', Constants.ObjectNameDuctLoad, @conditioned_space, 0.0, f_regain]
|
837
|
+
equip_act_infos << ['supply_lat_lk_to_cond', 'SupLatLkToCond', Constants.ObjectNameDuctLoad, @conditioned_space, 1.0 - f_regain, f_regain]
|
819
838
|
|
820
|
-
# Supply duct conduction load added to the
|
821
|
-
equip_act_infos << ['
|
839
|
+
# Supply duct conduction load added to the conditioned space
|
840
|
+
equip_act_infos << ['supply_cond_to_cond', 'SupCondToLv', Constants.ObjectNameDuctLoad, @conditioned_space, 0.0, f_regain]
|
822
841
|
|
823
842
|
# Return duct conduction load added to the return plenum zone
|
824
|
-
equip_act_infos << ['return_cond_to_rp', 'RetCondToRP',
|
843
|
+
equip_act_infos << ['return_cond_to_rp', 'RetCondToRP', Constants.ObjectNameDuctLoad, ra_duct_space, 0.0, f_regain]
|
825
844
|
|
826
845
|
# Return duct sensible leakage impact on the return plenum
|
827
|
-
equip_act_infos << ['return_sens_lk_to_rp', 'RetSensLkToRP',
|
846
|
+
equip_act_infos << ['return_sens_lk_to_rp', 'RetSensLkToRP', Constants.ObjectNameDuctLoad, ra_duct_space, 0.0, f_regain]
|
828
847
|
|
829
848
|
# Return duct latent leakage impact on the return plenum
|
830
|
-
equip_act_infos << ['return_lat_lk_to_rp', 'RetLatLkToRP',
|
849
|
+
equip_act_infos << ['return_lat_lk_to_rp', 'RetLatLkToRP', Constants.ObjectNameDuctLoad, ra_duct_space, 1.0 - f_regain, f_regain]
|
831
850
|
|
832
851
|
# Supply duct conduction impact on the duct zone
|
833
852
|
if not duct_location.is_a? OpenStudio::Model::ThermalZone # Outside or scheduled temperature
|
834
|
-
equip_act_infos << ['supply_cond_to_dz', 'SupCondToDZ',
|
853
|
+
equip_act_infos << ['supply_cond_to_dz', 'SupCondToDZ', nil, @conditioned_space, 0.0, 1.0] # Arbitrary space, all heat lost
|
835
854
|
else
|
836
|
-
equip_act_infos << ['supply_cond_to_dz', 'SupCondToDZ',
|
855
|
+
equip_act_infos << ['supply_cond_to_dz', 'SupCondToDZ', nil, duct_location.spaces[0], 0.0, 0.0]
|
837
856
|
end
|
838
857
|
|
839
858
|
# Return duct conduction impact on the duct zone
|
840
859
|
if not duct_location.is_a? OpenStudio::Model::ThermalZone # Outside or scheduled temperature
|
841
|
-
equip_act_infos << ['return_cond_to_dz', 'RetCondToDZ',
|
860
|
+
equip_act_infos << ['return_cond_to_dz', 'RetCondToDZ', nil, @conditioned_space, 0.0, 1.0] # Arbitrary space, all heat lost
|
842
861
|
else
|
843
|
-
equip_act_infos << ['return_cond_to_dz', 'RetCondToDZ',
|
862
|
+
equip_act_infos << ['return_cond_to_dz', 'RetCondToDZ', nil, duct_location.spaces[0], 0.0, 0.0]
|
844
863
|
end
|
845
864
|
|
846
865
|
# Supply duct sensible leakage impact on the duct zone
|
847
866
|
if not duct_location.is_a? OpenStudio::Model::ThermalZone # Outside or scheduled temperature
|
848
|
-
equip_act_infos << ['supply_sens_lk_to_dz', 'SupSensLkToDZ',
|
867
|
+
equip_act_infos << ['supply_sens_lk_to_dz', 'SupSensLkToDZ', nil, @conditioned_space, 0.0, 1.0] # Arbitrary space, all heat lost
|
849
868
|
else
|
850
|
-
equip_act_infos << ['supply_sens_lk_to_dz', 'SupSensLkToDZ',
|
869
|
+
equip_act_infos << ['supply_sens_lk_to_dz', 'SupSensLkToDZ', nil, duct_location.spaces[0], 0.0, 0.0]
|
851
870
|
end
|
852
871
|
|
853
872
|
# Supply duct latent leakage impact on the duct zone
|
854
873
|
if not duct_location.is_a? OpenStudio::Model::ThermalZone # Outside or scheduled temperature
|
855
|
-
equip_act_infos << ['supply_lat_lk_to_dz', 'SupLatLkToDZ',
|
874
|
+
equip_act_infos << ['supply_lat_lk_to_dz', 'SupLatLkToDZ', nil, @conditioned_space, 0.0, 1.0] # Arbitrary space, all heat lost
|
856
875
|
else
|
857
|
-
equip_act_infos << ['supply_lat_lk_to_dz', 'SupLatLkToDZ',
|
876
|
+
equip_act_infos << ['supply_lat_lk_to_dz', 'SupLatLkToDZ', nil, duct_location.spaces[0], 1.0, 0.0]
|
858
877
|
end
|
859
878
|
|
860
879
|
duct_vars = {}
|
@@ -870,34 +889,34 @@ class Airflow
|
|
870
889
|
equip_act_infos.each do |act_info|
|
871
890
|
var_name = "#{prefix}#{act_info[0]}"
|
872
891
|
object_name = "#{object_name_idx} #{prefix}#{act_info[1]}".gsub(' ', '_')
|
873
|
-
|
892
|
+
end_use = act_info[2]
|
874
893
|
space = act_info[3]
|
875
894
|
if is_cfis && (space == ra_duct_space)
|
876
895
|
# Move all CFIS return duct losses to the conditioned space so as to avoid extreme plenum temperatures
|
877
896
|
# due to mismatch between return plenum duct loads and airloop airflow rate (which does not actually
|
878
897
|
# increase due to the presence of CFIS).
|
879
|
-
space = @
|
898
|
+
space = @conditioned_space
|
880
899
|
end
|
881
900
|
frac_lat = act_info[4]
|
882
901
|
frac_lost = act_info[5]
|
883
902
|
if not is_cfis
|
884
903
|
duct_vars[var_name] = OpenStudio::Model::EnergyManagementSystemGlobalVariable.new(model, object_name)
|
885
904
|
end
|
886
|
-
duct_actuators[var_name] = create_other_equipment_object_and_actuator(model: model, name: object_name, space: space, frac_lat: frac_lat, frac_lost: frac_lost,
|
905
|
+
duct_actuators[var_name] = create_other_equipment_object_and_actuator(model: model, name: object_name, space: space, frac_lat: frac_lat, frac_lost: frac_lost, end_use: end_use)
|
887
906
|
end
|
888
907
|
end
|
889
908
|
|
890
|
-
# Two objects are required to model the air exchange between the duct zone and the
|
909
|
+
# Two objects are required to model the air exchange between the duct zone and the conditioned space since
|
891
910
|
# ZoneMixing objects can not account for direction of air flow (both are controlled by EMS)
|
892
911
|
|
893
912
|
# List of: [Var name, object name, space, frac load latent, frac load outside]
|
894
913
|
mix_act_infos = []
|
895
914
|
|
896
915
|
if duct_location.is_a? OpenStudio::Model::ThermalZone
|
897
|
-
# Accounts for leaks from the duct zone to the
|
898
|
-
mix_act_infos << ['
|
899
|
-
# Accounts for leaks from the
|
900
|
-
mix_act_infos << ['
|
916
|
+
# Accounts for leaks from the duct zone to the conditioned zone
|
917
|
+
mix_act_infos << ['dz_to_cond_flow_rate', 'ZoneMixDZToCond', @conditioned_zone, duct_location]
|
918
|
+
# Accounts for leaks from the conditioned zone to the duct zone
|
919
|
+
mix_act_infos << ['cond_to_dz_flow_rate', 'ZoneMixCondToDZ', duct_location, @conditioned_zone]
|
901
920
|
end
|
902
921
|
|
903
922
|
[false, true].each do |is_cfis|
|
@@ -922,6 +941,7 @@ class Airflow
|
|
922
941
|
zone_mixing.setSourceZone(source_zone)
|
923
942
|
duct_actuators[var_name] = OpenStudio::Model::EnergyManagementSystemActuator.new(zone_mixing, *EPlus::EMSActuatorZoneMixingFlowRate)
|
924
943
|
duct_actuators[var_name].setName("#{zone_mixing.name} act")
|
944
|
+
zone_mixing.additionalProperties.setFeature('ObjectType', Constants.ObjectNameDuctLoad)
|
925
945
|
end
|
926
946
|
end
|
927
947
|
|
@@ -965,7 +985,7 @@ class Airflow
|
|
965
985
|
|
966
986
|
duct_subroutine = OpenStudio::Model::EnergyManagementSystemSubroutine.new(model)
|
967
987
|
duct_subroutine.setName("#{object_name_idx} duct subroutine")
|
968
|
-
duct_subroutine.addLine("Set AH_MFR = #{ah_mfr_var.name}")
|
988
|
+
duct_subroutine.addLine("Set AH_MFR = #{ah_mfr_var.name} / #{unit_multiplier}")
|
969
989
|
duct_subroutine.addLine('If AH_MFR>0')
|
970
990
|
duct_subroutine.addLine(" Set AH_Tout = #{ah_tout_var.name}")
|
971
991
|
duct_subroutine.addLine(" Set AH_Wout = #{ah_wout_var.name}")
|
@@ -974,7 +994,7 @@ class Airflow
|
|
974
994
|
duct_subroutine.addLine(" Set Fan_RTF = #{@fan_rtf_var[object].name}")
|
975
995
|
duct_subroutine.addLine(" Set DZ_T = #{dz_t_var.name}")
|
976
996
|
duct_subroutine.addLine(" Set DZ_W = #{dz_w_var.name}")
|
977
|
-
duct_subroutine.addLine(" Set AH_VFR = #{ah_vfr_var.name}")
|
997
|
+
duct_subroutine.addLine(" Set AH_VFR = #{ah_vfr_var.name} / #{unit_multiplier}")
|
978
998
|
duct_subroutine.addLine(' Set h_SA = (@HFnTdbW AH_Tout AH_Wout)') # J/kg
|
979
999
|
duct_subroutine.addLine(' Set h_RA = (@HFnTdbW RA_T RA_W)') # J/kg
|
980
1000
|
duct_subroutine.addLine(' Set h_fg = (@HfgAirFnWTdb AH_Wout AH_Tout)') # J/kg
|
@@ -984,31 +1004,31 @@ class Airflow
|
|
984
1004
|
if not leakage_fracs[HPXML::DuctTypeSupply].nil?
|
985
1005
|
duct_subroutine.addLine(" Set f_sup = #{leakage_fracs[HPXML::DuctTypeSupply]}") # frac
|
986
1006
|
elsif not leakage_cfm25s[HPXML::DuctTypeSupply].nil?
|
987
|
-
duct_subroutine.addLine(" Set f_sup = #{UnitConversions.convert(leakage_cfm25s[HPXML::DuctTypeSupply], 'cfm', 'm^3/s').round(6)} / (#{@fan_mfr_max_var[object].name} * 1.0135)") # frac
|
1007
|
+
duct_subroutine.addLine(" Set f_sup = #{UnitConversions.convert(leakage_cfm25s[HPXML::DuctTypeSupply], 'cfm', 'm^3/s').round(6)} / (#{@fan_mfr_max_var[object].name}/#{unit_multiplier} * 1.0135)") # frac
|
988
1008
|
else
|
989
1009
|
duct_subroutine.addLine(' Set f_sup = 0.0') # frac
|
990
1010
|
end
|
991
1011
|
if not leakage_fracs[HPXML::DuctTypeReturn].nil?
|
992
1012
|
duct_subroutine.addLine(" Set f_ret = #{leakage_fracs[HPXML::DuctTypeReturn]}") # frac
|
993
1013
|
elsif not leakage_cfm25s[HPXML::DuctTypeReturn].nil?
|
994
|
-
duct_subroutine.addLine(" Set f_ret = #{UnitConversions.convert(leakage_cfm25s[HPXML::DuctTypeReturn], 'cfm', 'm^3/s').round(6)} / (#{@fan_mfr_max_var[object].name} * 1.0135)") # frac
|
1014
|
+
duct_subroutine.addLine(" Set f_ret = #{UnitConversions.convert(leakage_cfm25s[HPXML::DuctTypeReturn], 'cfm', 'm^3/s').round(6)} / (#{@fan_mfr_max_var[object].name}/#{unit_multiplier} * 1.0135)") # frac
|
995
1015
|
else
|
996
1016
|
duct_subroutine.addLine(' Set f_ret = 0.0') # frac
|
997
1017
|
end
|
998
1018
|
duct_subroutine.addLine(' Set sup_lk_mfr = f_sup * AH_MFR') # kg/s
|
999
1019
|
duct_subroutine.addLine(' Set ret_lk_mfr = f_ret * AH_MFR') # kg/s
|
1000
1020
|
|
1001
|
-
# Supply leakage to
|
1002
|
-
duct_subroutine.addLine(' Set
|
1003
|
-
duct_subroutine.addLine(' Set
|
1004
|
-
duct_subroutine.addLine(' Set
|
1021
|
+
# Supply leakage to conditioned space
|
1022
|
+
duct_subroutine.addLine(' Set SupTotLkToCond = sup_lk_mfr*(h_RA - h_SA)') # W
|
1023
|
+
duct_subroutine.addLine(' Set SupLatLkToCond = sup_lk_mfr*h_fg*(RA_W-AH_Wout)') # W
|
1024
|
+
duct_subroutine.addLine(' Set SupSensLkToCond = SupTotLkToCond-SupLatLkToCond') # W
|
1005
1025
|
|
1006
1026
|
# Supply conduction
|
1007
1027
|
duct_subroutine.addLine(" Set supply_ua = #{UnitConversions.convert(ua_values[HPXML::DuctTypeSupply], 'Btu/(hr*F)', 'W/K').round(3)}")
|
1008
1028
|
duct_subroutine.addLine(' Set eTm = 0-((Fan_RTF/(AH_MFR*air_cp))*supply_ua)')
|
1009
1029
|
duct_subroutine.addLine(' Set t_sup = DZ_T+((AH_Tout-DZ_T)*(@Exp eTm))') # deg-C
|
1010
|
-
duct_subroutine.addLine(' Set
|
1011
|
-
duct_subroutine.addLine(' Set SupCondToDZ = 0-
|
1030
|
+
duct_subroutine.addLine(' Set SupCondToCond = AH_MFR*air_cp*(t_sup-AH_Tout)') # W
|
1031
|
+
duct_subroutine.addLine(' Set SupCondToDZ = 0-SupCondToCond') # W
|
1012
1032
|
|
1013
1033
|
# Return conduction
|
1014
1034
|
duct_subroutine.addLine(" Set return_ua = #{UnitConversions.convert(ua_values[HPXML::DuctTypeReturn], 'Btu/(hr*F)', 'W/K').round(3)}")
|
@@ -1022,9 +1042,9 @@ class Airflow
|
|
1022
1042
|
duct_subroutine.addLine(' Set RetSensLkToRP = ret_lk_mfr*air_cp*(DZ_T-RA_T)') # W
|
1023
1043
|
|
1024
1044
|
# Supply leakage to duct zone
|
1025
|
-
# The below terms are not the same as
|
1045
|
+
# The below terms are not the same as SupLatLkToCond and SupSensLkToCond.
|
1026
1046
|
# To understand why, suppose the AHzone temperature equals the supply air temperature. In this case, the terms below
|
1027
|
-
# should be zero while
|
1047
|
+
# should be zero while SupLatLkToCond and SupSensLkToCond should still be non-zero.
|
1028
1048
|
duct_subroutine.addLine(' Set SupTotLkToDZ = sup_lk_mfr*(h_SA-h_DZ)') # W
|
1029
1049
|
duct_subroutine.addLine(' Set SupLatLkToDZ = sup_lk_mfr*h_fg*(AH_Wout-DZ_W)') # W
|
1030
1050
|
duct_subroutine.addLine(' Set SupSensLkToDZ = SupTotLkToDZ-SupLatLkToDZ') # W
|
@@ -1033,17 +1053,17 @@ class Airflow
|
|
1033
1053
|
duct_subroutine.addLine(" Set oa_vfr = #{f_oa} * f_imbalance * AH_VFR") # m3/s
|
1034
1054
|
duct_subroutine.addLine(' Set sup_lk_vfr = f_sup * AH_VFR') # m3/s
|
1035
1055
|
duct_subroutine.addLine(' Set ret_lk_vfr = f_ret * AH_VFR') # m3/s
|
1036
|
-
duct_subroutine.addLine(' If f_sup > f_ret') #
|
1037
|
-
duct_subroutine.addLine(' Set
|
1038
|
-
duct_subroutine.addLine(' Set
|
1039
|
-
duct_subroutine.addLine(' Else') #
|
1040
|
-
duct_subroutine.addLine(' Set
|
1041
|
-
duct_subroutine.addLine(' Set
|
1056
|
+
duct_subroutine.addLine(' If f_sup > f_ret') # Conditioned zone is depressurized relative to duct zone
|
1057
|
+
duct_subroutine.addLine(' Set ZoneMixCondToDZ = 0') # m3/s
|
1058
|
+
duct_subroutine.addLine(' Set ZoneMixDZToCond = (sup_lk_vfr-ret_lk_vfr)-oa_vfr') # m3/s
|
1059
|
+
duct_subroutine.addLine(' Else') # Conditioned zone is pressurized relative to duct zone
|
1060
|
+
duct_subroutine.addLine(' Set ZoneMixCondToDZ = (ret_lk_vfr-sup_lk_vfr)+oa_vfr') # m3/s
|
1061
|
+
duct_subroutine.addLine(' Set ZoneMixDZToCond = 0') # m3/s
|
1042
1062
|
duct_subroutine.addLine(' EndIf')
|
1043
1063
|
duct_subroutine.addLine('Else') # No air handler flow rate
|
1044
|
-
duct_subroutine.addLine(' Set
|
1045
|
-
duct_subroutine.addLine(' Set
|
1046
|
-
duct_subroutine.addLine(' Set
|
1064
|
+
duct_subroutine.addLine(' Set SupLatLkToCond = 0')
|
1065
|
+
duct_subroutine.addLine(' Set SupSensLkToCond = 0')
|
1066
|
+
duct_subroutine.addLine(' Set SupCondToCond = 0')
|
1047
1067
|
duct_subroutine.addLine(' Set RetCondToRP = 0')
|
1048
1068
|
duct_subroutine.addLine(' Set RetLatLkToRP = 0')
|
1049
1069
|
duct_subroutine.addLine(' Set RetSensLkToRP = 0')
|
@@ -1051,12 +1071,12 @@ class Airflow
|
|
1051
1071
|
duct_subroutine.addLine(' Set SupCondToDZ = 0')
|
1052
1072
|
duct_subroutine.addLine(' Set SupLatLkToDZ = 0')
|
1053
1073
|
duct_subroutine.addLine(' Set SupSensLkToDZ = 0')
|
1054
|
-
duct_subroutine.addLine(' Set
|
1055
|
-
duct_subroutine.addLine(' Set
|
1074
|
+
duct_subroutine.addLine(' Set ZoneMixCondToDZ = 0') # m3/s
|
1075
|
+
duct_subroutine.addLine(' Set ZoneMixDZToCond = 0') # m3/s
|
1056
1076
|
duct_subroutine.addLine('EndIf')
|
1057
|
-
duct_subroutine.addLine("Set #{duct_vars['
|
1058
|
-
duct_subroutine.addLine("Set #{duct_vars['
|
1059
|
-
duct_subroutine.addLine("Set #{duct_vars['
|
1077
|
+
duct_subroutine.addLine("Set #{duct_vars['supply_lat_lk_to_cond'].name} = SupLatLkToCond")
|
1078
|
+
duct_subroutine.addLine("Set #{duct_vars['supply_sens_lk_to_cond'].name} = SupSensLkToCond")
|
1079
|
+
duct_subroutine.addLine("Set #{duct_vars['supply_cond_to_cond'].name} = SupCondToCond")
|
1060
1080
|
duct_subroutine.addLine("Set #{duct_vars['return_cond_to_rp'].name} = RetCondToRP")
|
1061
1081
|
duct_subroutine.addLine("Set #{duct_vars['return_lat_lk_to_rp'].name} = RetLatLkToRP")
|
1062
1082
|
duct_subroutine.addLine("Set #{duct_vars['return_sens_lk_to_rp'].name} = RetSensLkToRP")
|
@@ -1064,11 +1084,11 @@ class Airflow
|
|
1064
1084
|
duct_subroutine.addLine("Set #{duct_vars['supply_cond_to_dz'].name} = SupCondToDZ")
|
1065
1085
|
duct_subroutine.addLine("Set #{duct_vars['supply_lat_lk_to_dz'].name} = SupLatLkToDZ")
|
1066
1086
|
duct_subroutine.addLine("Set #{duct_vars['supply_sens_lk_to_dz'].name} = SupSensLkToDZ")
|
1067
|
-
if not duct_actuators['
|
1068
|
-
duct_subroutine.addLine("Set #{duct_vars['
|
1087
|
+
if not duct_actuators['cond_to_dz_flow_rate'].nil?
|
1088
|
+
duct_subroutine.addLine("Set #{duct_vars['cond_to_dz_flow_rate'].name} = ZoneMixCondToDZ")
|
1069
1089
|
end
|
1070
|
-
if not duct_actuators['
|
1071
|
-
duct_subroutine.addLine("Set #{duct_vars['
|
1090
|
+
if not duct_actuators['dz_to_cond_flow_rate'].nil?
|
1091
|
+
duct_subroutine.addLine("Set #{duct_vars['dz_to_cond_flow_rate'].name} = ZoneMixDZToCond")
|
1072
1092
|
end
|
1073
1093
|
|
1074
1094
|
# Duct Program
|
@@ -1088,9 +1108,9 @@ class Airflow
|
|
1088
1108
|
duct_program.addLine("Set #{dz_t_var.name} = #{dz_t_sensor.name}")
|
1089
1109
|
duct_program.addLine("Set #{dz_w_var.name} = #{dz_w}")
|
1090
1110
|
duct_program.addLine("Run #{duct_subroutine.name}")
|
1091
|
-
duct_program.addLine("Set #{duct_actuators['
|
1092
|
-
duct_program.addLine("Set #{duct_actuators['
|
1093
|
-
duct_program.addLine("Set #{duct_actuators['
|
1111
|
+
duct_program.addLine("Set #{duct_actuators['supply_sens_lk_to_cond'].name} = #{duct_vars['supply_sens_lk_to_cond'].name}")
|
1112
|
+
duct_program.addLine("Set #{duct_actuators['supply_lat_lk_to_cond'].name} = #{duct_vars['supply_lat_lk_to_cond'].name}")
|
1113
|
+
duct_program.addLine("Set #{duct_actuators['supply_cond_to_cond'].name} = #{duct_vars['supply_cond_to_cond'].name}")
|
1094
1114
|
duct_program.addLine("Set #{duct_actuators['return_sens_lk_to_rp'].name} = #{duct_vars['return_sens_lk_to_rp'].name}")
|
1095
1115
|
duct_program.addLine("Set #{duct_actuators['return_lat_lk_to_rp'].name} = #{duct_vars['return_lat_lk_to_rp'].name}")
|
1096
1116
|
duct_program.addLine("Set #{duct_actuators['return_cond_to_rp'].name} = #{duct_vars['return_cond_to_rp'].name}")
|
@@ -1098,11 +1118,11 @@ class Airflow
|
|
1098
1118
|
duct_program.addLine("Set #{duct_actuators['supply_cond_to_dz'].name} = #{duct_vars['supply_cond_to_dz'].name}")
|
1099
1119
|
duct_program.addLine("Set #{duct_actuators['supply_sens_lk_to_dz'].name} = #{duct_vars['supply_sens_lk_to_dz'].name}")
|
1100
1120
|
duct_program.addLine("Set #{duct_actuators['supply_lat_lk_to_dz'].name} = #{duct_vars['supply_lat_lk_to_dz'].name}")
|
1101
|
-
if not duct_actuators['
|
1102
|
-
duct_program.addLine("Set #{duct_actuators['
|
1121
|
+
if not duct_actuators['dz_to_cond_flow_rate'].nil?
|
1122
|
+
duct_program.addLine("Set #{duct_actuators['dz_to_cond_flow_rate'].name} = #{duct_vars['dz_to_cond_flow_rate'].name}")
|
1103
1123
|
end
|
1104
|
-
if not duct_actuators['
|
1105
|
-
duct_program.addLine("Set #{duct_actuators['
|
1124
|
+
if not duct_actuators['cond_to_dz_flow_rate'].nil?
|
1125
|
+
duct_program.addLine("Set #{duct_actuators['cond_to_dz_flow_rate'].name} = #{duct_vars['cond_to_dz_flow_rate'].name}")
|
1106
1126
|
end
|
1107
1127
|
|
1108
1128
|
if @cfis_airloop.values.include? object
|
@@ -1124,9 +1144,9 @@ class Airflow
|
|
1124
1144
|
duct_program.addLine(" Set #{ra_t_var.name} = #{ra_t_sensor.name}")
|
1125
1145
|
duct_program.addLine(" Set #{ra_w_var.name} = #{ra_w_sensor.name}")
|
1126
1146
|
duct_program.addLine(" Run #{duct_subroutine.name}")
|
1127
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1128
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1129
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1147
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_supply_sens_lk_to_cond'].name} = #{duct_vars['supply_sens_lk_to_cond'].name}")
|
1148
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_supply_lat_lk_to_cond'].name} = #{duct_vars['supply_lat_lk_to_cond'].name}")
|
1149
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_supply_cond_to_cond'].name} = #{duct_vars['supply_cond_to_cond'].name}")
|
1130
1150
|
duct_program.addLine(" Set #{duct_actuators['cfis_return_sens_lk_to_rp'].name} = #{duct_vars['return_sens_lk_to_rp'].name}")
|
1131
1151
|
duct_program.addLine(" Set #{duct_actuators['cfis_return_lat_lk_to_rp'].name} = #{duct_vars['return_lat_lk_to_rp'].name}")
|
1132
1152
|
duct_program.addLine(" Set #{duct_actuators['cfis_return_cond_to_rp'].name} = #{duct_vars['return_cond_to_rp'].name}")
|
@@ -1134,17 +1154,17 @@ class Airflow
|
|
1134
1154
|
duct_program.addLine(" Set #{duct_actuators['cfis_supply_cond_to_dz'].name} = #{duct_vars['supply_cond_to_dz'].name}")
|
1135
1155
|
duct_program.addLine(" Set #{duct_actuators['cfis_supply_sens_lk_to_dz'].name} = #{duct_vars['supply_sens_lk_to_dz'].name}")
|
1136
1156
|
duct_program.addLine(" Set #{duct_actuators['cfis_supply_lat_lk_to_dz'].name} = #{duct_vars['supply_lat_lk_to_dz'].name}")
|
1137
|
-
if not duct_actuators['
|
1138
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1157
|
+
if not duct_actuators['dz_to_cond_flow_rate'].nil?
|
1158
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_dz_to_cond_flow_rate'].name} = #{duct_vars['dz_to_cond_flow_rate'].name}")
|
1139
1159
|
end
|
1140
|
-
if not duct_actuators['
|
1141
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1160
|
+
if not duct_actuators['cond_to_dz_flow_rate'].nil?
|
1161
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_cond_to_dz_flow_rate'].name} = #{duct_vars['cond_to_dz_flow_rate'].name}")
|
1142
1162
|
end
|
1143
1163
|
duct_program.addLine('Else')
|
1144
1164
|
end
|
1145
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1146
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1147
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1165
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_supply_sens_lk_to_cond'].name} = 0")
|
1166
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_supply_lat_lk_to_cond'].name} = 0")
|
1167
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_supply_cond_to_cond'].name} = 0")
|
1148
1168
|
duct_program.addLine(" Set #{duct_actuators['cfis_return_sens_lk_to_rp'].name} = 0")
|
1149
1169
|
duct_program.addLine(" Set #{duct_actuators['cfis_return_lat_lk_to_rp'].name} = 0")
|
1150
1170
|
duct_program.addLine(" Set #{duct_actuators['cfis_return_cond_to_rp'].name} = 0")
|
@@ -1152,11 +1172,11 @@ class Airflow
|
|
1152
1172
|
duct_program.addLine(" Set #{duct_actuators['cfis_supply_cond_to_dz'].name} = 0")
|
1153
1173
|
duct_program.addLine(" Set #{duct_actuators['cfis_supply_sens_lk_to_dz'].name} = 0")
|
1154
1174
|
duct_program.addLine(" Set #{duct_actuators['cfis_supply_lat_lk_to_dz'].name} = 0")
|
1155
|
-
if not duct_actuators['
|
1156
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1175
|
+
if not duct_actuators['dz_to_cond_flow_rate'].nil?
|
1176
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_dz_to_cond_flow_rate'].name} = 0")
|
1157
1177
|
end
|
1158
|
-
if not duct_actuators['
|
1159
|
-
duct_program.addLine(" Set #{duct_actuators['
|
1178
|
+
if not duct_actuators['cond_to_dz_flow_rate'].nil?
|
1179
|
+
duct_program.addLine(" Set #{duct_actuators['cfis_cond_to_dz_flow_rate'].name} = 0")
|
1160
1180
|
end
|
1161
1181
|
if add_cfis_duct_losses
|
1162
1182
|
duct_program.addLine('EndIf')
|
@@ -1272,7 +1292,7 @@ class Airflow
|
|
1272
1292
|
equip_def.setName(obj_name)
|
1273
1293
|
equip = OpenStudio::Model::ElectricEquipment.new(equip_def)
|
1274
1294
|
equip.setName(obj_name)
|
1275
|
-
equip.setSpace(@
|
1295
|
+
equip.setSpace(@conditioned_space) # no heat gain, so assign the equipment to an arbitrary space
|
1276
1296
|
equip_def.setDesignLevel(vent_object.fan_power * vent_object.count)
|
1277
1297
|
equip_def.setFractionRadiant(0)
|
1278
1298
|
equip_def.setFractionLatent(0)
|
@@ -1284,20 +1304,20 @@ class Airflow
|
|
1284
1304
|
end
|
1285
1305
|
|
1286
1306
|
def self.apply_dryer_exhaust(model, vented_dryer, schedules_file, index, unavailable_periods)
|
1287
|
-
obj_name = "#{Constants.
|
1307
|
+
obj_name = "#{Constants.ObjectNameClothesDryer} exhaust #{index}"
|
1288
1308
|
|
1289
1309
|
# Create schedule
|
1290
1310
|
obj_sch = nil
|
1291
1311
|
if not schedules_file.nil?
|
1292
1312
|
obj_sch_name = SchedulesFile::ColumnClothesDryer
|
1293
|
-
obj_sch = schedules_file.create_schedule_file(col_name: obj_sch_name)
|
1313
|
+
obj_sch = schedules_file.create_schedule_file(model, col_name: obj_sch_name)
|
1294
1314
|
full_load_hrs = schedules_file.annual_equivalent_full_load_hrs(col_name: obj_sch_name)
|
1295
1315
|
end
|
1296
1316
|
if obj_sch.nil?
|
1297
1317
|
cd_weekday_sch = vented_dryer.weekday_fractions
|
1298
1318
|
cd_weekend_sch = vented_dryer.weekend_fractions
|
1299
1319
|
cd_monthly_sch = vented_dryer.monthly_multipliers
|
1300
|
-
obj_sch = MonthWeekdayWeekendSchedule.new(model,
|
1320
|
+
obj_sch = MonthWeekdayWeekendSchedule.new(model, obj_name + ' schedule', cd_weekday_sch, cd_weekend_sch, cd_monthly_sch, Constants.ScheduleTypeLimitsFraction, unavailable_periods: unavailable_periods)
|
1301
1321
|
obj_sch = obj_sch.schedule
|
1302
1322
|
obj_sch_name = obj_sch.name.to_s
|
1303
1323
|
full_load_hrs = Schedule.annual_equivalent_full_load_hrs(@year, obj_sch)
|
@@ -1318,6 +1338,7 @@ class Airflow
|
|
1318
1338
|
def self.calc_hrv_erv_effectiveness(vent_mech_fans)
|
1319
1339
|
# Create the mapping between mech vent instance and the effectiveness results
|
1320
1340
|
hrv_erv_effectiveness_map = {}
|
1341
|
+
p_atm = UnitConversions.convert(1.0, 'atm', 'psi')
|
1321
1342
|
vent_mech_fans.each do |vent_mech|
|
1322
1343
|
hrv_erv_effectiveness_map[vent_mech] = {}
|
1323
1344
|
|
@@ -1331,7 +1352,7 @@ class Airflow
|
|
1331
1352
|
cp_a = 1006.0
|
1332
1353
|
p_fan = vent_mech.average_unit_fan_power # Watts
|
1333
1354
|
|
1334
|
-
m_fan = UnitConversions.convert(vent_mech_cfm, 'cfm', 'm^3/s') *
|
1355
|
+
m_fan = UnitConversions.convert(vent_mech_cfm, 'cfm', 'm^3/s') * UnitConversions.convert(Psychrometrics.rhoD_fT_w_P(UnitConversions.convert(t_sup_in, 'C', 'F'), w_sup_in, p_atm), 'lbm/ft^3', 'kg/m^3') # kg/s
|
1335
1356
|
|
1336
1357
|
if not vent_mech.sensible_recovery_efficiency.nil?
|
1337
1358
|
# The following is derived from CSA 439, Clause 9.3.3.1, Eq. 12:
|
@@ -1367,7 +1388,7 @@ class Airflow
|
|
1367
1388
|
t_exh_in = 24.0
|
1368
1389
|
w_exh_in = 0.0092
|
1369
1390
|
|
1370
|
-
m_fan = UnitConversions.convert(vent_mech_cfm, 'cfm', 'm^3/s') * UnitConversions.convert(Psychrometrics.rhoD_fT_w_P(UnitConversions.convert(t_sup_in, 'C', 'F'), w_sup_in,
|
1391
|
+
m_fan = UnitConversions.convert(vent_mech_cfm, 'cfm', 'm^3/s') * UnitConversions.convert(Psychrometrics.rhoD_fT_w_P(UnitConversions.convert(t_sup_in, 'C', 'F'), w_sup_in, p_atm), 'lbm/ft^3', 'kg/m^3') # kg/s
|
1371
1392
|
|
1372
1393
|
t_sup_out_gross = t_sup_in - vent_mech_sens_eff * (t_sup_in - t_exh_in)
|
1373
1394
|
t_sup_out = t_sup_out_gross + p_fan / (m_fan * cp_a)
|
@@ -1519,7 +1540,7 @@ class Airflow
|
|
1519
1540
|
equip_def.setName(obj_name)
|
1520
1541
|
equip = OpenStudio::Model::ElectricEquipment.new(equip_def)
|
1521
1542
|
equip.setName(obj_name)
|
1522
|
-
equip.setSpace(@
|
1543
|
+
equip.setSpace(@conditioned_space)
|
1523
1544
|
equip_def.setFractionRadiant(0)
|
1524
1545
|
equip_def.setFractionLatent(0)
|
1525
1546
|
equip.setSchedule(avail_sch)
|
@@ -1541,9 +1562,9 @@ class Airflow
|
|
1541
1562
|
def self.setup_mech_vent_vars_actuators(model:, program:)
|
1542
1563
|
# Actuators for mech vent fan
|
1543
1564
|
sens_name = "#{Constants.ObjectNameMechanicalVentilationHouseFan} sensible load"
|
1544
|
-
fan_sens_load_actuator = create_other_equipment_object_and_actuator(model: model, name: sens_name, space: @
|
1565
|
+
fan_sens_load_actuator = create_other_equipment_object_and_actuator(model: model, name: sens_name, space: @conditioned_space, frac_lat: 0.0, frac_lost: 0.0, end_use: Constants.ObjectNameMechanicalVentilationHouseFan)
|
1545
1566
|
lat_name = "#{Constants.ObjectNameMechanicalVentilationHouseFan} latent load"
|
1546
|
-
fan_lat_load_actuator = create_other_equipment_object_and_actuator(model: model, name: lat_name, space: @
|
1567
|
+
fan_lat_load_actuator = create_other_equipment_object_and_actuator(model: model, name: lat_name, space: @conditioned_space, frac_lat: 1.0, frac_lost: 0.0, end_use: Constants.ObjectNameMechanicalVentilationHouseFan)
|
1547
1568
|
program.addLine("Set #{fan_sens_load_actuator.name} = 0.0")
|
1548
1569
|
program.addLine("Set #{fan_lat_load_actuator.name} = 0.0")
|
1549
1570
|
# Air property at inlet nodes on both sides
|
@@ -1627,6 +1648,9 @@ class Airflow
|
|
1627
1648
|
infil_program.addLine('Set Qinf_adj = Qtot - Qu - Qb')
|
1628
1649
|
end
|
1629
1650
|
infil_program.addLine("Set #{infil_flow_actuator.name} = Qinf_adj")
|
1651
|
+
|
1652
|
+
create_timeseries_flowrate_ems_output_var(model, 'Qfan', infil_program)
|
1653
|
+
create_timeseries_flowrate_ems_output_var(model, infil_flow_actuator.name.to_s, infil_program)
|
1630
1654
|
end
|
1631
1655
|
|
1632
1656
|
def self.calculate_fan_loads(infil_program, vent_mech_erv_hrv_tot, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, q_var, preconditioned = false)
|
@@ -1663,15 +1687,15 @@ class Airflow
|
|
1663
1687
|
infil_program.addLine('Set ZoneInEnth = ERVSupOutEnth')
|
1664
1688
|
infil_program.addLine('Set ZoneInTemp = ERVSupOutTemp')
|
1665
1689
|
end
|
1666
|
-
infil_program.addLine('Set
|
1667
|
-
infil_program.addLine('Set
|
1668
|
-
infil_program.addLine('Set
|
1690
|
+
infil_program.addLine('Set FanTotalToCond = Fan_MFR * (ZoneInEnth - ZoneAirEnth)')
|
1691
|
+
infil_program.addLine('Set FanSensToCond = Fan_MFR * ZoneCp * (ZoneInTemp - ZoneTemp)')
|
1692
|
+
infil_program.addLine('Set FanLatToCond = FanTotalToCond - FanSensToCond')
|
1669
1693
|
|
1670
1694
|
# Actuator,
|
1671
1695
|
# If preconditioned, handle actuators later in calculate_precond_loads
|
1672
1696
|
if not preconditioned
|
1673
|
-
infil_program.addLine("Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} +
|
1674
|
-
infil_program.addLine("Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} +
|
1697
|
+
infil_program.addLine("Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} + FanSensToCond")
|
1698
|
+
infil_program.addLine("Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} + FanLatToCond")
|
1675
1699
|
end
|
1676
1700
|
end
|
1677
1701
|
|
@@ -1680,19 +1704,20 @@ class Airflow
|
|
1680
1704
|
# Assume introducing no sensible loads to zone if preconditioned
|
1681
1705
|
if not vent_mech_preheat.empty?
|
1682
1706
|
htg_stp_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Thermostat Heating Setpoint Temperature')
|
1683
|
-
htg_stp_sensor.setName(
|
1684
|
-
htg_stp_sensor.setKeyName(@
|
1707
|
+
htg_stp_sensor.setName('htg stp s')
|
1708
|
+
htg_stp_sensor.setKeyName(@conditioned_zone.name.to_s)
|
1685
1709
|
infil_program.addLine("Set HtgStp = #{htg_stp_sensor.name}") # heating thermostat setpoint
|
1686
1710
|
end
|
1687
1711
|
if not vent_mech_precool.empty?
|
1688
1712
|
clg_stp_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Thermostat Cooling Setpoint Temperature')
|
1689
|
-
clg_stp_sensor.setName(
|
1690
|
-
clg_stp_sensor.setKeyName(@
|
1713
|
+
clg_stp_sensor.setName('clg stp s')
|
1714
|
+
clg_stp_sensor.setKeyName(@conditioned_zone.name.to_s)
|
1691
1715
|
infil_program.addLine("Set ClgStp = #{clg_stp_sensor.name}") # cooling thermostat setpoint
|
1692
1716
|
end
|
1693
1717
|
vent_mech_preheat.each_with_index do |f_preheat, i|
|
1694
1718
|
infil_program.addLine("If (OASupInTemp < HtgStp) && (#{clg_ssn_sensor.name} < 1)")
|
1695
|
-
|
1719
|
+
cnt = model.getOtherEquipments.select { |e| e.endUseSubcategory.start_with? Constants.ObjectNameMechanicalVentilationPreheating }.size # Ensure unique meter for each preheating system
|
1720
|
+
htg_energy_actuator = create_other_equipment_object_and_actuator(model: model, name: "shared mech vent preheating energy #{i}", space: @conditioned_space, frac_lat: 0.0, frac_lost: 1.0, hpxml_fuel_type: f_preheat.preheating_fuel, end_use: "#{Constants.ObjectNameMechanicalVentilationPreheating}#{cnt + 1}")
|
1696
1721
|
htg_energy_actuator.actuatedComponent.get.additionalProperties.setFeature('HPXML_ID', f_preheat.id) # Used by reporting measure
|
1697
1722
|
infil_program.addLine(" Set Qpreheat = #{UnitConversions.convert(f_preheat.average_oa_unit_flow_rate, 'cfm', 'm^3/s').round(4)}")
|
1698
1723
|
if [HPXML::MechVentTypeERV, HPXML::MechVentTypeHRV].include? f_preheat.fan_type
|
@@ -1706,7 +1731,7 @@ class Airflow
|
|
1706
1731
|
infil_program.addLine(' Set FanSensToSpt = Fan_MFR * ZoneCp * (ZoneInTemp - HtgStp)')
|
1707
1732
|
infil_program.addLine(" Set PreHeatingWatt = (-FanSensToSpt) * #{f_preheat.preheating_fraction_load_served}")
|
1708
1733
|
infil_program.addLine(" Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} + PreHeatingWatt")
|
1709
|
-
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} -
|
1734
|
+
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} - FanLatToCond")
|
1710
1735
|
infil_program.addLine(' Else')
|
1711
1736
|
infil_program.addLine(' Set PreHeatingWatt = 0.0')
|
1712
1737
|
infil_program.addLine(' EndIf')
|
@@ -1717,7 +1742,8 @@ class Airflow
|
|
1717
1742
|
end
|
1718
1743
|
vent_mech_precool.each_with_index do |f_precool, i|
|
1719
1744
|
infil_program.addLine("If (OASupInTemp > ClgStp) && (#{clg_ssn_sensor.name} > 0)")
|
1720
|
-
|
1745
|
+
cnt = model.getOtherEquipments.select { |e| e.endUseSubcategory.start_with? Constants.ObjectNameMechanicalVentilationPrecooling }.size # Ensure unique meter for each precooling system
|
1746
|
+
clg_energy_actuator = create_other_equipment_object_and_actuator(model: model, name: "shared mech vent precooling energy #{i}", space: @conditioned_space, frac_lat: 0.0, frac_lost: 1.0, hpxml_fuel_type: f_precool.precooling_fuel, end_use: "#{Constants.ObjectNameMechanicalVentilationPrecooling}#{cnt + 1}")
|
1721
1747
|
clg_energy_actuator.actuatedComponent.get.additionalProperties.setFeature('HPXML_ID', f_precool.id) # Used by reporting measure
|
1722
1748
|
infil_program.addLine(" Set Qprecool = #{UnitConversions.convert(f_precool.average_oa_unit_flow_rate, 'cfm', 'm^3/s').round(4)}")
|
1723
1749
|
if [HPXML::MechVentTypeERV, HPXML::MechVentTypeHRV].include? f_precool.fan_type
|
@@ -1731,7 +1757,7 @@ class Airflow
|
|
1731
1757
|
infil_program.addLine(' Set FanSensToSpt = Fan_MFR * ZoneCp * (ZoneInTemp - ClgStp)')
|
1732
1758
|
infil_program.addLine(" Set PreCoolingWatt = FanSensToSpt * #{f_precool.precooling_fraction_load_served}")
|
1733
1759
|
infil_program.addLine(" Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} - PreCoolingWatt")
|
1734
|
-
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} -
|
1760
|
+
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} - FanLatToCond") # Fixme:Does this assumption still apply?
|
1735
1761
|
infil_program.addLine(' Else')
|
1736
1762
|
infil_program.addLine(' Set PreCoolingWatt = 0.0')
|
1737
1763
|
infil_program.addLine(' EndIf')
|
@@ -1742,7 +1768,7 @@ class Airflow
|
|
1742
1768
|
end
|
1743
1769
|
end
|
1744
1770
|
|
1745
|
-
def self.apply_infiltration_ventilation_to_conditioned(model, site, vent_fans_mech,
|
1771
|
+
def self.apply_infiltration_ventilation_to_conditioned(model, site, vent_fans_mech, conditioned_ach50, conditioned_const_ach, infil_volume, infil_height, weather,
|
1746
1772
|
vent_fans_kitchen, vent_fans_bath, vented_dryers, has_flue_chimney_in_cond_space, clg_ssn_sensor, schedules_file,
|
1747
1773
|
vent_fans_cfis_suppl, unavailable_periods)
|
1748
1774
|
# Categorize fans into different types
|
@@ -1779,16 +1805,18 @@ class Airflow
|
|
1779
1805
|
infil_flow = OpenStudio::Model::SpaceInfiltrationDesignFlowRate.new(model)
|
1780
1806
|
infil_flow.setName(Constants.ObjectNameInfiltration + ' flow')
|
1781
1807
|
infil_flow.setSchedule(model.alwaysOnDiscreteSchedule)
|
1782
|
-
infil_flow.setSpace(@
|
1808
|
+
infil_flow.setSpace(@conditioned_space)
|
1783
1809
|
infil_flow_actuator = OpenStudio::Model::EnergyManagementSystemActuator.new(infil_flow, *EPlus::EMSActuatorZoneInfiltrationFlowRate)
|
1784
1810
|
infil_flow_actuator.setName("#{infil_flow.name} act")
|
1811
|
+
infil_flow.additionalProperties.setFeature('ObjectType', Constants.ObjectNameInfiltration)
|
1785
1812
|
|
1786
|
-
#
|
1813
|
+
# Conditioned Space Infiltration Calculation/Program
|
1787
1814
|
infil_program = OpenStudio::Model::EnergyManagementSystemProgram.new(model)
|
1815
|
+
infil_program.additionalProperties.setFeature('ObjectType', Constants.ObjectNameInfiltration)
|
1788
1816
|
infil_program.setName(Constants.ObjectNameInfiltration + ' program')
|
1789
1817
|
|
1790
1818
|
# Calculate infiltration without adjustment by ventilation
|
1791
|
-
apply_infiltration_to_conditioned(site,
|
1819
|
+
apply_infiltration_to_conditioned(site, conditioned_ach50, conditioned_const_ach, infil_program, weather, has_flue_chimney_in_cond_space, infil_volume, infil_height)
|
1792
1820
|
|
1793
1821
|
# Common variable and load actuators across multiple mech vent calculations, create only once
|
1794
1822
|
fan_sens_load_actuator, fan_lat_load_actuator = setup_mech_vent_vars_actuators(model: model, program: infil_program)
|
@@ -1825,11 +1853,11 @@ class Airflow
|
|
1825
1853
|
end
|
1826
1854
|
|
1827
1855
|
def self.apply_infiltration_and_ventilation_fans(model, weather, site, vent_fans_mech, vent_fans_kitchen, vent_fans_bath, vented_dryers,
|
1828
|
-
has_flue_chimney_in_cond_space,
|
1856
|
+
has_flue_chimney_in_cond_space, conditioned_ach50, conditioned_const_ach, infil_volume, infil_height, vented_attic,
|
1829
1857
|
vented_crawl, clg_ssn_sensor, schedules_file, vent_fans_cfis_suppl, unavailable_periods)
|
1830
1858
|
|
1831
1859
|
# Infiltration for unconditioned spaces
|
1832
|
-
apply_infiltration_to_garage(model, site,
|
1860
|
+
apply_infiltration_to_garage(model, site, conditioned_ach50)
|
1833
1861
|
apply_infiltration_to_unconditioned_basement(model)
|
1834
1862
|
apply_infiltration_to_vented_crawlspace(model, weather, vented_crawl)
|
1835
1863
|
apply_infiltration_to_unvented_crawlspace(model)
|
@@ -1837,23 +1865,23 @@ class Airflow
|
|
1837
1865
|
apply_infiltration_to_unvented_attic(model)
|
1838
1866
|
|
1839
1867
|
# Infiltration/ventilation for conditioned space
|
1840
|
-
apply_infiltration_ventilation_to_conditioned(model, site, vent_fans_mech,
|
1868
|
+
apply_infiltration_ventilation_to_conditioned(model, site, vent_fans_mech, conditioned_ach50, conditioned_const_ach, infil_volume, infil_height, weather,
|
1841
1869
|
vent_fans_kitchen, vent_fans_bath, vented_dryers, has_flue_chimney_in_cond_space, clg_ssn_sensor, schedules_file,
|
1842
1870
|
vent_fans_cfis_suppl, unavailable_periods)
|
1843
1871
|
end
|
1844
1872
|
|
1845
|
-
def self.apply_infiltration_to_conditioned(site,
|
1873
|
+
def self.apply_infiltration_to_conditioned(site, conditioned_ach50, conditioned_const_ach, infil_program, weather, has_flue_chimney_in_cond_space, infil_volume, infil_height)
|
1846
1874
|
site_ap = site.additional_properties
|
1847
1875
|
|
1848
|
-
if
|
1876
|
+
if conditioned_ach50.to_f > 0
|
1849
1877
|
# Based on "Field Validation of Algebraic Equations for Stack and
|
1850
1878
|
# Wind Driven Air Infiltration Calculations" by Walker and Wilson (1998)
|
1851
1879
|
|
1852
|
-
outside_air_density = UnitConversions.convert(weather.header.LocalPressure, 'atm', 'Btu/ft^3') / (Gas.Air.r * (weather.data.AnnualAvgDrybulb
|
1880
|
+
outside_air_density = UnitConversions.convert(weather.header.LocalPressure, 'atm', 'Btu/ft^3') / (Gas.Air.r * UnitConversions.convert(weather.data.AnnualAvgDrybulb, 'F', 'R'))
|
1853
1881
|
|
1854
1882
|
n_i = InfilPressureExponent
|
1855
|
-
|
1856
|
-
a_o =
|
1883
|
+
conditioned_sla = get_infiltration_SLA_from_ACH50(conditioned_ach50, n_i, @cfa, infil_volume) # Calculate SLA
|
1884
|
+
a_o = conditioned_sla * @cfa # Effective Leakage Area (ft^2)
|
1857
1885
|
|
1858
1886
|
# Flow Coefficient (cfm/inH2O^n) (based on ASHRAE HoF)
|
1859
1887
|
inf_conv_factor = 776.25 # [ft/min]/[inH2O^(1/2)*ft^(3/2)/lbm^(1/2)]
|
@@ -1903,7 +1931,7 @@ class Airflow
|
|
1903
1931
|
f_i = 0.0 # Additive flue function (eq. 12)
|
1904
1932
|
end
|
1905
1933
|
f_s = ((1.0 + n_i * r_i) / (n_i + 1.0)) * (0.5 - 0.5 * m_i**1.2)**(n_i + 1.0) + f_i
|
1906
|
-
stack_coef = f_s * (UnitConversions.convert(outside_air_density * Constants.g * infil_height, 'lbm/(ft*s^2)', 'inH2O') / (Constants.AssumedInsideTemp
|
1934
|
+
stack_coef = f_s * (UnitConversions.convert(outside_air_density * Constants.g * infil_height, 'lbm/(ft*s^2)', 'inH2O') / UnitConversions.convert(Constants.AssumedInsideTemp, 'F', 'R'))**n_i # inH2O^n/R^n
|
1907
1935
|
|
1908
1936
|
# Calculate wind coefficient
|
1909
1937
|
if not @spaces[HPXML::LocationCrawlspaceVented].nil?
|
@@ -1940,9 +1968,8 @@ class Airflow
|
|
1940
1968
|
infil_program.addLine('Set Qinf = (((c*Cs*(dT^n))^2)+temp1)^0.5')
|
1941
1969
|
infil_program.addLine('Set Qinf = (@Max Qinf 0)')
|
1942
1970
|
|
1943
|
-
elsif
|
1944
|
-
|
1945
|
-
infil_program.addLine("Set Qinf = #{living_ach * UnitConversions.convert(infil_volume, 'ft^3', 'm^3') / UnitConversions.convert(1.0, 'hr', 's')}")
|
1971
|
+
elsif conditioned_const_ach.to_f > 0
|
1972
|
+
infil_program.addLine("Set Qinf = #{conditioned_const_ach * UnitConversions.convert(infil_volume, 'ft^3', 'm^3') / UnitConversions.convert(1.0, 'hr', 's')}")
|
1946
1973
|
else
|
1947
1974
|
infil_program.addLine('Set Qinf = 0')
|
1948
1975
|
end
|
@@ -1957,7 +1984,7 @@ class Airflow
|
|
1957
1984
|
f_t_SG = site_ap.site_terrain_multiplier * ((space_height + coord_z) / 32.8)**site_ap.site_terrain_exponent / (site_ap.terrain_multiplier * (site_ap.height / 32.8)**site_ap.terrain_exponent)
|
1958
1985
|
f_s_SG = 2.0 / 3.0 * (1 + hor_lk_frac / 2.0) * (2.0 * neutral_level * (1.0 - neutral_level))**0.5 / (neutral_level**0.5 + (1.0 - neutral_level)**0.5)
|
1959
1986
|
f_w_SG = site_ap.s_g_shielding_coef * (1.0 - hor_lk_frac)**(1.0 / 3.0) * f_t_SG
|
1960
|
-
c_s_SG = f_s_SG**2.0 * Constants.g * space_height / (Constants.AssumedInsideTemp
|
1987
|
+
c_s_SG = f_s_SG**2.0 * Constants.g * space_height / UnitConversions.convert(Constants.AssumedInsideTemp, 'F', 'R')
|
1961
1988
|
c_w_SG = f_w_SG**2.0
|
1962
1989
|
return c_w_SG, c_s_SG
|
1963
1990
|
end
|