openstudio-standards 0.4.0 → 0.5.0.rc1

Sign up to get free protection for your applications and to get access to all the features.
Files changed (376) hide show
  1. checksums.yaml +4 -4
  2. data/data/inventory/thermal_bridging.csv +90 -0
  3. data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
  4. data/data/standards/manage_OpenStudio_Standards.rb +1 -1
  5. data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
  6. data/lib/openstudio-standards/btap/analysis.rb +8 -8
  7. data/lib/openstudio-standards/btap/bridging.rb +664 -645
  8. data/lib/openstudio-standards/btap/btap.model.rb +14 -14
  9. data/lib/openstudio-standards/btap/btap.rb +7 -7
  10. data/lib/openstudio-standards/btap/btap_result.rb +1 -1
  11. data/lib/openstudio-standards/btap/economics.rb +23 -23
  12. data/lib/openstudio-standards/btap/envelope.rb +8 -8
  13. data/lib/openstudio-standards/btap/equest.rb +1 -1
  14. data/lib/openstudio-standards/btap/geometry.rb +2 -2
  15. data/lib/openstudio-standards/btap/mpc.rb +7 -7
  16. data/lib/openstudio-standards/btap/schedules.rb +1 -1
  17. data/lib/openstudio-standards/btap/simmanager.rb +4 -4
  18. data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
  19. data/lib/openstudio-standards/btap/utilities.rb +6 -6
  20. data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
  21. data/lib/openstudio-standards/constructions/information.rb +83 -0
  22. data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
  23. data/lib/openstudio-standards/constructions/modify.rb +80 -0
  24. data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
  25. data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
  26. data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
  27. data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
  28. data/lib/openstudio-standards/daylighting/space.rb +47 -0
  29. data/lib/openstudio-standards/geometry/create.rb +801 -0
  30. data/lib/openstudio-standards/geometry/create_bar.rb +2171 -0
  31. data/lib/openstudio-standards/geometry/information.rb +462 -0
  32. data/lib/openstudio-standards/geometry/modify.rb +48 -0
  33. data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
  34. data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
  35. data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
  36. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
  37. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
  38. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  39. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
  40. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  41. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
  42. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
  43. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  44. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
  45. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
  46. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  47. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
  48. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
  49. data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
  50. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
  51. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
  52. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
  53. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
  54. data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
  55. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  56. data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  57. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
  58. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
  59. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
  60. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
  61. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
  62. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
  63. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
  64. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
  65. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
  66. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
  67. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
  68. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
  69. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
  70. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
  71. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
  72. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
  73. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
  74. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
  75. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
  76. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
  77. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
  78. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
  79. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
  80. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
  81. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
  82. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
  83. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
  84. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
  85. data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
  86. data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
  87. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
  88. data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
  89. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
  90. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
  91. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
  92. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
  93. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
  94. data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
  95. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
  96. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
  97. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
  98. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
  99. data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
  100. data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
  101. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
  102. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
  103. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
  104. data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
  105. data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
  106. data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
  107. data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
  108. data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
  109. data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
  110. data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
  111. data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
  112. data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
  113. data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
  114. data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
  115. data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
  116. data/lib/openstudio-standards/qaqc/eui.rb +213 -0
  117. data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
  118. data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
  119. data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
  120. data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
  121. data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
  122. data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
  123. data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
  124. data/lib/openstudio-standards/schedules/create.rb +364 -0
  125. data/lib/openstudio-standards/schedules/information.rb +169 -0
  126. data/lib/openstudio-standards/schedules/modify.rb +445 -0
  127. data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
  128. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
  129. data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
  130. data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
  131. data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
  132. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
  133. data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
  134. data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
  135. data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
  136. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
  137. data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
  138. data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
  139. data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
  140. data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
  141. data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
  142. data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
  143. data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
  144. data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
  145. data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
  146. data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
  147. data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
  148. data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
  149. data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
  150. data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
  151. data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
  152. data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
  153. data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
  154. data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
  155. data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
  156. data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
  157. data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
  158. data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
  159. data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
  160. data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
  161. data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
  162. data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
  163. data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
  164. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
  165. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
  166. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
  167. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
  168. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
  169. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
  170. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
  171. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
  172. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
  173. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
  174. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
  175. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
  176. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
  177. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
  178. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
  179. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
  180. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
  181. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
  182. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
  183. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
  184. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
  185. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
  186. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
  187. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
  188. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
  189. data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
  190. data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
  191. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
  192. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
  193. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
  194. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
  195. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
  196. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
  197. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
  198. data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
  199. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
  200. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
  201. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
  202. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
  203. data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
  204. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
  205. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
  206. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
  207. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
  208. data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
  209. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
  210. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
  211. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
  212. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
  213. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
  214. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
  215. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
  216. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
  217. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
  218. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
  219. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
  220. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
  221. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
  222. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
  223. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
  224. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
  225. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
  226. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
  227. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
  228. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
  229. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
  230. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
  231. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
  232. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
  233. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
  234. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
  235. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
  236. data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
  237. data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
  238. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
  239. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
  240. data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
  241. data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
  242. data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
  243. data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
  244. data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
  245. data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
  246. data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
  247. data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
  248. data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
  249. data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
  250. data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
  251. data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
  252. data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
  253. data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
  254. data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
  255. data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
  256. data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
  257. data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
  258. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
  259. data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
  260. data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
  261. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
  262. data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
  263. data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
  264. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
  265. data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
  266. data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
  267. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
  268. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
  269. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
  270. data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
  271. data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
  272. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
  273. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
  274. data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
  275. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
  276. data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
  277. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
  278. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
  279. data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
  280. data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
  281. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
  282. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
  283. data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
  284. data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
  285. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
  286. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
  287. data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
  288. data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
  289. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
  290. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
  291. data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
  292. data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
  293. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
  294. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
  295. data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
  296. data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
  297. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
  298. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
  299. data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
  300. data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
  301. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
  302. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
  303. data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
  304. data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
  305. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
  306. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
  307. data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
  308. data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
  309. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
  310. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
  311. data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
  312. data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
  313. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
  314. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
  315. data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
  316. data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
  317. data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
  318. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
  319. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
  320. data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
  321. data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
  322. data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
  323. data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
  324. data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
  325. data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
  326. data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
  327. data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
  328. data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
  329. data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
  330. data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
  331. data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
  332. data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
  333. data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
  334. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
  335. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
  336. data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
  337. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
  338. data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
  339. data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
  340. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
  341. data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
  342. data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
  343. data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
  344. data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
  345. data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
  346. data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
  347. data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
  348. data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
  349. data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
  350. data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
  351. data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
  352. data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
  353. data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
  354. data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
  355. data/lib/openstudio-standards/utilities/assertion.rb +128 -0
  356. data/lib/openstudio-standards/utilities/logging.rb +2 -3
  357. data/lib/openstudio-standards/utilities/object_info.rb +39 -18
  358. data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
  359. data/lib/openstudio-standards/utilities/simulation.rb +24 -11
  360. data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
  361. data/lib/openstudio-standards/version.rb +1 -1
  362. data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
  363. data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
  364. data/lib/openstudio-standards/weather/information.rb +35 -0
  365. data/lib/openstudio-standards.rb +69 -5
  366. metadata +52 -16
  367. data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
  368. data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
  369. data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
  370. data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
  371. data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
  372. data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
  373. data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
  374. data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
  375. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
  376. data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -5,8 +5,51 @@ require_relative 'openstudio-standards/version'
5
5
  module OpenstudioStandards
6
6
  require 'json' # Used to load standards JSON files
7
7
 
8
- # HVAC sizing
9
- require_relative 'openstudio-standards/hvac_sizing/Siz.Model'
8
+ # Load Modules
9
+
10
+ # Geometry Module
11
+ require_relative 'openstudio-standards/geometry/create'
12
+ require_relative 'openstudio-standards/geometry/create_bar'
13
+ require_relative 'openstudio-standards/geometry/modify'
14
+ require_relative 'openstudio-standards/geometry/information'
15
+
16
+ # Construction Module
17
+ require_relative 'openstudio-standards/constructions/information'
18
+ require_relative 'openstudio-standards/constructions/modify'
19
+ require_relative 'openstudio-standards/constructions/materials/modify'
20
+
21
+ # Daylighting Module
22
+ require_relative 'openstudio-standards/daylighting/space'
23
+
24
+ # Schedules Module
25
+ require_relative 'openstudio-standards/schedules/create'
26
+ require_relative 'openstudio-standards/schedules/modify'
27
+ require_relative 'openstudio-standards/schedules/information'
28
+
29
+ # HVAC Module
30
+ require_relative 'openstudio-standards/hvac/cbecs_hvac'
31
+
32
+ # CreateTypical Module
33
+ require_relative 'openstudio-standards/create_typical/enumerations'
34
+ require_relative 'openstudio-standards/create_typical/space_type_ratios'
35
+ require_relative 'openstudio-standards/create_typical/create_typical'
36
+ require_relative 'openstudio-standards/create_typical/space_type_blend'
37
+
38
+ # QAQC Module
39
+ require_relative 'openstudio-standards/qaqc/calibration'
40
+ require_relative 'openstudio-standards/qaqc/envelope'
41
+ require_relative 'openstudio-standards/qaqc/eui'
42
+ require_relative 'openstudio-standards/qaqc/hvac'
43
+ require_relative 'openstudio-standards/qaqc/internal_loads'
44
+ require_relative 'openstudio-standards/qaqc/schedules'
45
+ require_relative 'openstudio-standards/qaqc/service_water_heating'
46
+ require_relative 'openstudio-standards/qaqc/weather_files'
47
+ require_relative 'openstudio-standards/qaqc/zone_conditions'
48
+ require_relative 'openstudio-standards/qaqc/create_results'
49
+ require_relative 'openstudio-standards/qaqc/reporting'
50
+
51
+ # Weather Module
52
+ require_relative 'openstudio-standards/weather/information'
10
53
 
11
54
  # Weather data
12
55
  require_relative 'openstudio-standards/weather/Weather.Model'
@@ -25,6 +68,7 @@ module OpenstudioStandards
25
68
  require_relative 'openstudio-standards/utilities/schedule_translator'
26
69
  require_relative 'openstudio-standards/utilities/array'
27
70
  require_relative 'openstudio-standards/utilities/object_info'
71
+ require_relative 'openstudio-standards/utilities/assertion'
28
72
 
29
73
  stds = 'openstudio-standards/standards'
30
74
  proto = 'openstudio-standards/prototypes'
@@ -282,13 +326,14 @@ module OpenstudioStandards
282
326
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas"
283
327
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater"
284
328
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR"
285
- require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower"
286
- require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed"
287
329
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat"
288
330
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface"
289
331
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone"
290
332
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType"
291
333
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.Surface"
334
+ require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir"
335
+ require_relative "#{stds}/ashrae_90_1_prm/userdata_csv/userdata_enums.rb"
336
+ require_relative "#{stds}/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData"
292
337
 
293
338
  # 90.1-PRM-2019
294
339
  require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019"
@@ -354,6 +399,26 @@ module OpenstudioStandards
354
399
  require_relative "#{stds}/deer/deer.AirLoopHVAC"
355
400
  require_relative "#{stds}/deer/deer.Space"
356
401
  require_relative "#{stds}/deer/deer.PlanarSurface"
402
+ # DEER 2003
403
+ require_relative "#{stds}/deer/deer_2003/deer_2003.ThermalZone"
404
+ # DEER 2007
405
+ require_relative "#{stds}/deer/deer_2007/deer_2007.ThermalZone"
406
+ # DEER 2011
407
+ require_relative "#{stds}/deer/deer_2011/deer_2011.ThermalZone"
408
+ # DEER 2014
409
+ require_relative "#{stds}/deer/deer_2014/deer_2014.Space"
410
+ require_relative "#{stds}/deer/deer_2014/deer_2014.ThermalZone"
411
+ # DEER 2015
412
+ require_relative "#{stds}/deer/deer_2015/deer_2015.Space"
413
+ require_relative "#{stds}/deer/deer_2015/deer_2015.ThermalZone"
414
+ # DEER 2017
415
+ require_relative "#{stds}/deer/deer_2017/deer_2017.Space"
416
+ require_relative "#{stds}/deer/deer_2017/deer_2017.ThermalZone"
417
+ # DEER 2020
418
+ require_relative "#{stds}/deer/deer_2020/deer_2020.AirLoopHVAC"
419
+ require_relative "#{stds}/deer/deer_2020/deer_2020.FanVariableVolume"
420
+ require_relative "#{stds}/deer/deer_2020/deer_2020.Space"
421
+ require_relative "#{stds}/deer/deer_2020/deer_2020.ThermalZone"
357
422
  # CBES Common
358
423
  require_relative "#{stds}/cbes/cbes.AirLoopHVAC"
359
424
  require_relative "#{stds}/cbes/cbes.Model"
@@ -497,7 +562,6 @@ module OpenstudioStandards
497
562
  require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff"
498
563
  require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume"
499
564
  require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent"
500
- require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model"
501
565
  require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators"
502
566
  require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems"
503
567
  # ZE AEDG Multifamily
metadata CHANGED
@@ -1,7 +1,7 @@
1
1
  --- !ruby/object:Gem::Specification
2
2
  name: openstudio-standards
3
3
  version: !ruby/object:Gem::Version
4
- version: 0.4.0
4
+ version: 0.5.0.rc1
5
5
  platform: ruby
6
6
  authors:
7
7
  - Andrew Parker
@@ -25,25 +25,26 @@ authors:
25
25
  - Xuechen (Jerry) Lei
26
26
  - Juan Gonzalez Matamoros
27
27
  - Jeremy Lerond
28
+ - Carlos Duarte
28
29
  autorequire:
29
30
  bindir: bin
30
31
  cert_chain: []
31
- date: 2023-04-11 00:00:00.000000000 Z
32
+ date: 2023-10-13 00:00:00.000000000 Z
32
33
  dependencies:
33
34
  - !ruby/object:Gem::Dependency
34
35
  name: minitest-reporters
35
36
  requirement: !ruby/object:Gem::Requirement
36
37
  requirements:
37
- - - ">="
38
+ - - '='
38
39
  - !ruby/object:Gem::Version
39
- version: '0'
40
+ version: 1.6.1
40
41
  type: :development
41
42
  prerelease: false
42
43
  version_requirements: !ruby/object:Gem::Requirement
43
44
  requirements:
44
- - - ">="
45
+ - - '='
45
46
  - !ruby/object:Gem::Version
46
- version: '0'
47
+ version: 1.6.1
47
48
  - !ruby/object:Gem::Dependency
48
49
  name: minitest-parallel_fork
49
50
  requirement: !ruby/object:Gem::Requirement
@@ -625,7 +626,8 @@ files:
625
626
  - data/geometry/DOERefSmallOffice.json
626
627
  - data/geometry/DOERefWarehouse.json
627
628
  - data/geometry/DOERefWarehouse.osm
628
- - data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx
629
+ - data/inventory/thermal_bridging.csv
630
+ - data/standards/OpenStudio_Standards-deer-comstock.xlsx
629
631
  - data/standards/exclude_list.csv
630
632
  - data/standards/export_OpenStudio_libraries.rb
631
633
  - data/standards/legacy_dd_results.csv
@@ -1349,12 +1351,21 @@ files:
1349
1351
  - lib/openstudio-standards/btap/utilities/weatherData1_xlsx_to_json.rb
1350
1352
  - lib/openstudio-standards/btap/vintagizer.rb
1351
1353
  - lib/openstudio-standards/btap/visualization.rb
1352
- - lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb
1353
- - lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb
1354
- - lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb
1355
- - lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb
1356
- - lib/openstudio-standards/hvac_sizing/Siz.Model.rb
1357
- - lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb
1354
+ - lib/openstudio-standards/constructions/information.rb
1355
+ - lib/openstudio-standards/constructions/materials/modify.rb
1356
+ - lib/openstudio-standards/constructions/modify.rb
1357
+ - lib/openstudio-standards/create_typical/create_typical.rb
1358
+ - lib/openstudio-standards/create_typical/enumerations.rb
1359
+ - lib/openstudio-standards/create_typical/space_type_blend.rb
1360
+ - lib/openstudio-standards/create_typical/space_type_ratios.rb
1361
+ - lib/openstudio-standards/daylighting/space.rb
1362
+ - lib/openstudio-standards/geometry/create.rb
1363
+ - lib/openstudio-standards/geometry/create_bar.rb
1364
+ - lib/openstudio-standards/geometry/information.rb
1365
+ - lib/openstudio-standards/geometry/modify.rb
1366
+ - lib/openstudio-standards/hvac/air_loop/information.rb
1367
+ - lib/openstudio-standards/hvac/cbecs_hvac.rb
1368
+ - lib/openstudio-standards/hvac/setpoint_managers/information.rb
1358
1369
  - lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb
1359
1370
  - lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb
1360
1371
  - lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb
@@ -1408,7 +1419,6 @@ files:
1408
1419
  - lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb
1409
1420
  - lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb
1410
1421
  - lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
1411
- - lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb
1412
1422
  - lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb
1413
1423
  - lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb
1414
1424
  - lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb
@@ -1490,7 +1500,21 @@ files:
1490
1500
  - lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb
1491
1501
  - lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb
1492
1502
  - lib/openstudio-standards/prototypes/deer/deer.Model.rb
1503
+ - lib/openstudio-standards/qaqc/calibration.rb
1504
+ - lib/openstudio-standards/qaqc/create_results.rb
1505
+ - lib/openstudio-standards/qaqc/envelope.rb
1506
+ - lib/openstudio-standards/qaqc/eui.rb
1507
+ - lib/openstudio-standards/qaqc/hvac.rb
1508
+ - lib/openstudio-standards/qaqc/internal_loads.rb
1509
+ - lib/openstudio-standards/qaqc/reporting.rb
1510
+ - lib/openstudio-standards/qaqc/schedules.rb
1511
+ - lib/openstudio-standards/qaqc/service_water_heating.rb
1512
+ - lib/openstudio-standards/qaqc/weather_files.rb
1513
+ - lib/openstudio-standards/qaqc/zone_conditions.rb
1493
1514
  - lib/openstudio-standards/refs/references.rb
1515
+ - lib/openstudio-standards/schedules/create.rb
1516
+ - lib/openstudio-standards/schedules/information.rb
1517
+ - lib/openstudio-standards/schedules/modify.rb
1494
1518
  - lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb
1495
1519
  - lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb
1496
1520
  - lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb
@@ -1714,6 +1738,7 @@ files:
1714
1738
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb
1715
1739
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb
1716
1740
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb
1741
+ - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb
1717
1742
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb
1718
1743
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json
1719
1744
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json
@@ -1756,6 +1781,7 @@ files:
1756
1781
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb
1757
1782
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb
1758
1783
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb
1784
+ - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb
1759
1785
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb
1760
1786
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json
1761
1787
  - lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json
@@ -1946,8 +1972,7 @@ files:
1946
1972
  - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb
1947
1973
  - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb
1948
1974
  - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb
1949
- - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb
1950
- - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb
1975
+ - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb
1951
1976
  - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Fan.rb
1952
1977
  - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb
1953
1978
  - lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb
@@ -1992,6 +2017,7 @@ files:
1992
2017
  - lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json
1993
2018
  - lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.materials.json
1994
2019
  - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_building_rotation_exception.md
2020
+ - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md
1995
2021
  - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/check_pump_power_and_control.md
1996
2022
  - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/dcv.md
1997
2023
  - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/dcv_implementation.png
@@ -2011,11 +2037,13 @@ files:
2011
2037
  - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/unmet_load_hours.md
2012
2038
  - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/vav_parallel_piu_terminals_fan_control.md
2013
2039
  - lib/openstudio-standards/standards/ashrae_90_1_prm/docs/vav_terminals_min_flow_setpoint.md
2040
+ - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb
2014
2041
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_airloop_hvac.csv
2015
2042
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_airloop_hvac_doas.csv
2016
2043
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_building.csv
2017
2044
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_design_specification_outdoor_air.csv
2018
2045
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_electric_equipment.csv
2046
+ - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb
2019
2047
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_exterior_lights.csv
2020
2048
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_gas_equipment.csv
2021
2049
  - lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_lights.csv
@@ -2512,6 +2540,7 @@ files:
2512
2540
  - lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.chillers.json
2513
2541
  - lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.construction_properties.json
2514
2542
  - lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.construction_sets.json
2543
+ - lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json
2515
2544
  - lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.elevators.json
2516
2545
  - lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ext_ltg.json
2517
2546
  - lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.heat_pumps.json
@@ -2748,6 +2777,8 @@ files:
2748
2777
  - lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb
2749
2778
  - lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json
2750
2779
  - lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json
2780
+ - lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json
2781
+ - lib/openstudio-standards/standards/necb/ECMS/data/chillers.json
2751
2782
  - lib/openstudio-standards/standards/necb/ECMS/data/curves.json
2752
2783
  - lib/openstudio-standards/standards/necb/ECMS/data/equip_eff_lim.json
2753
2784
  - lib/openstudio-standards/standards/necb/ECMS/data/erv.json
@@ -2767,6 +2798,7 @@ files:
2767
2798
  - lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb
2768
2799
  - lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb
2769
2800
  - lib/openstudio-standards/standards/necb/NECB2011/data/boilers.json
2801
+ - lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json
2770
2802
  - lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json
2771
2803
  - lib/openstudio-standards/standards/necb/NECB2011/data/climate_zone_sets.json
2772
2804
  - lib/openstudio-standards/standards/necb/NECB2011/data/constants.json
@@ -2783,6 +2815,8 @@ files:
2783
2815
  - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm
2784
2816
  - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/MediumOffice.osm
2785
2817
  - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/MidriseApartment.osm
2818
+ - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm
2819
+ - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm
2786
2820
  - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Outpatient.osm
2787
2821
  - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/PrimarySchool.osm
2788
2822
  - lib/openstudio-standards/standards/necb/NECB2011/data/geometry/QuickServiceRestaurant.osm
@@ -2891,6 +2925,7 @@ files:
2891
2925
  - lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb
2892
2926
  - lib/openstudio-standards/standards/standard.rb
2893
2927
  - lib/openstudio-standards/utilities/array.rb
2928
+ - lib/openstudio-standards/utilities/assertion.rb
2894
2929
  - lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb
2895
2930
  - lib/openstudio-standards/utilities/delete_all_objs_except_geo.rb
2896
2931
  - lib/openstudio-standards/utilities/generate_prototype_database.rb
@@ -2908,6 +2943,7 @@ files:
2908
2943
  - lib/openstudio-standards/version.rb
2909
2944
  - lib/openstudio-standards/weather/Weather.Model.rb
2910
2945
  - lib/openstudio-standards/weather/Weather.stat_file.rb
2946
+ - lib/openstudio-standards/weather/information.rb
2911
2947
  homepage: http://openstudio.net
2912
2948
  licenses:
2913
2949
  - LGPL
@@ -1,59 +0,0 @@
1
-
2
- # Reopen the OpenStudio class to add methods to apply standards to this object
3
- class OpenStudio::Model::AirLoopHVAC
4
-
5
- # Retrieves an airloop sum of air terminal minimum heating flow rates: sum(Vpz_min)
6
- def autosizeSumMinimumHeatingAirFlowRates
7
- result = OpenStudio::OptionalDouble.new
8
- name = self.name.get.upcase
9
- sql = self.model.sqlFile
10
- if sql.is_initialized
11
- sql = sql.get
12
- query = "SELECT Value
13
- FROM tabulardatawithstrings
14
- WHERE ReportName='ComponentSizingSummary'
15
- AND ReportForString='Entire Facility'
16
- AND TableName='AirLoopHVAC'
17
- AND ColumnName='Sum of Air Terminal Minimum Heating Flow Rates'
18
- AND RowName='#{name}'
19
- AND Units='m3/s'"
20
- val = sql.execAndReturnFirstDouble(query)
21
- if val.is_initialized
22
- result = OpenStudio::OptionalDouble.new(val.get)
23
- end
24
- else
25
- OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Model has no sql file containing results, cannot lookup data.')
26
- end
27
-
28
- return result.to_f
29
-
30
- end
31
-
32
- # Retrieve an airloop's sum of air terminal maximum flow rates: sum(Vpz)
33
- def autosizeSumAirTerminalMaxAirFlowRate
34
- result = OpenStudio::OptionalDouble.new
35
- name = self.name.get.upcase
36
- sql = self.model.sqlFile
37
- if sql.is_initialized
38
- sql = sql.get
39
- query = "SELECT Value
40
- FROM tabulardatawithstrings
41
- WHERE ReportName='ComponentSizingSummary'
42
- AND ReportForString='Entire Facility'
43
- AND TableName='AirLoopHVAC'
44
- AND ColumnName='Sum of Air Terminal Maximum Flow Rates'
45
- AND RowName='#{name}'
46
- AND Units='m3/s'"
47
- val = sql.execAndReturnFirstDouble(query)
48
- if val.is_initialized
49
- result = OpenStudio::OptionalDouble.new(val.get)
50
- end
51
- else
52
- OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Model has no sql file containing results, cannot lookup data.')
53
- end
54
-
55
- return result.to_f
56
-
57
- end
58
-
59
- end
@@ -1,13 +0,0 @@
1
-
2
- # open the class to add methods to return sizing values
3
- class OpenStudio::Model::CoilCoolingWater
4
-
5
- # returns the autosized design coil load
6
- def autosizedDesignCoilLoad
7
-
8
- return self.getAutosizedValue('Design Size Design Coil Load', 'W')
9
-
10
- end
11
-
12
-
13
- end
@@ -1,36 +0,0 @@
1
-
2
- ###### IMPORTANT NOTE ######
3
- # These methods should be done via extension to OS model objects
4
- # directly in the C++ SDK.
5
- ###### IMPORTANT NOTE ######
6
-
7
- class OpenStudio::Model::HVACComponent
8
- # Returns the number of individual pieces of equipment
9
- # represented by a particular HVAC component. Pulls from
10
- # the additionalProperties object attached to the component.
11
- # This can be used during the application of efficiency
12
- # levels that are based on component capacities, flowrates, etc.
13
- # @return [Integer] the number of components, 1 if not set
14
- def component_quantity
15
- addl_props = self.additionalProperties
16
- if addl_props.getFeatureAsInteger('component_quantity').is_initialized
17
- comp_qty = addl_props.getFeatureAsInteger('component_quantity').get
18
- else
19
- comp_qty = 1
20
- end
21
-
22
- return comp_qty
23
- end
24
-
25
- # Sets the number of individual pieces of equipment
26
- # represented by a particular HVAC component. Uses the
27
- # additionalProperties object attached to the component.
28
- # This can be used during the application of efficiency
29
- # levels that are based on component capacities, flowrates, etc.
30
- # @param comp_qty [Integer] the number of individual pieces of equipment
31
- # represented by this HVAC component
32
- # @return [Bool] returns true if successful, false if not
33
- def set_component_quantity(comp_qty)
34
- return self.additionalProperties.setFeature('component_quantity', comp_qty)
35
- end
36
- end