openstudio-standards 0.4.0 → 0.5.0.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/inventory/thermal_bridging.csv +90 -0
- data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
- data/lib/openstudio-standards/btap/analysis.rb +8 -8
- data/lib/openstudio-standards/btap/bridging.rb +664 -645
- data/lib/openstudio-standards/btap/btap.model.rb +14 -14
- data/lib/openstudio-standards/btap/btap.rb +7 -7
- data/lib/openstudio-standards/btap/btap_result.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +23 -23
- data/lib/openstudio-standards/btap/envelope.rb +8 -8
- data/lib/openstudio-standards/btap/equest.rb +1 -1
- data/lib/openstudio-standards/btap/geometry.rb +2 -2
- data/lib/openstudio-standards/btap/mpc.rb +7 -7
- data/lib/openstudio-standards/btap/schedules.rb +1 -1
- data/lib/openstudio-standards/btap/simmanager.rb +4 -4
- data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
- data/lib/openstudio-standards/btap/utilities.rb +6 -6
- data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
- data/lib/openstudio-standards/constructions/information.rb +83 -0
- data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
- data/lib/openstudio-standards/constructions/modify.rb +80 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
- data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
- data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
- data/lib/openstudio-standards/daylighting/space.rb +47 -0
- data/lib/openstudio-standards/geometry/create.rb +801 -0
- data/lib/openstudio-standards/geometry/create_bar.rb +2171 -0
- data/lib/openstudio-standards/geometry/information.rb +462 -0
- data/lib/openstudio-standards/geometry/modify.rb +48 -0
- data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
- data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
- data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
- data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
- data/lib/openstudio-standards/qaqc/eui.rb +213 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
- data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
- data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
- data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
- data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
- data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
- data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
- data/lib/openstudio-standards/schedules/create.rb +364 -0
- data/lib/openstudio-standards/schedules/information.rb +169 -0
- data/lib/openstudio-standards/schedules/modify.rb +445 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
- data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
- data/lib/openstudio-standards/utilities/assertion.rb +128 -0
- data/lib/openstudio-standards/utilities/logging.rb +2 -3
- data/lib/openstudio-standards/utilities/object_info.rb +39 -18
- data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
- data/lib/openstudio-standards/utilities/simulation.rb +24 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
- data/lib/openstudio-standards/weather/information.rb +35 -0
- data/lib/openstudio-standards.rb +69 -5
- metadata +52 -16
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
data/lib/openstudio-standards.rb
CHANGED
@@ -5,8 +5,51 @@ require_relative 'openstudio-standards/version'
|
|
5
5
|
module OpenstudioStandards
|
6
6
|
require 'json' # Used to load standards JSON files
|
7
7
|
|
8
|
-
#
|
9
|
-
|
8
|
+
# Load Modules
|
9
|
+
|
10
|
+
# Geometry Module
|
11
|
+
require_relative 'openstudio-standards/geometry/create'
|
12
|
+
require_relative 'openstudio-standards/geometry/create_bar'
|
13
|
+
require_relative 'openstudio-standards/geometry/modify'
|
14
|
+
require_relative 'openstudio-standards/geometry/information'
|
15
|
+
|
16
|
+
# Construction Module
|
17
|
+
require_relative 'openstudio-standards/constructions/information'
|
18
|
+
require_relative 'openstudio-standards/constructions/modify'
|
19
|
+
require_relative 'openstudio-standards/constructions/materials/modify'
|
20
|
+
|
21
|
+
# Daylighting Module
|
22
|
+
require_relative 'openstudio-standards/daylighting/space'
|
23
|
+
|
24
|
+
# Schedules Module
|
25
|
+
require_relative 'openstudio-standards/schedules/create'
|
26
|
+
require_relative 'openstudio-standards/schedules/modify'
|
27
|
+
require_relative 'openstudio-standards/schedules/information'
|
28
|
+
|
29
|
+
# HVAC Module
|
30
|
+
require_relative 'openstudio-standards/hvac/cbecs_hvac'
|
31
|
+
|
32
|
+
# CreateTypical Module
|
33
|
+
require_relative 'openstudio-standards/create_typical/enumerations'
|
34
|
+
require_relative 'openstudio-standards/create_typical/space_type_ratios'
|
35
|
+
require_relative 'openstudio-standards/create_typical/create_typical'
|
36
|
+
require_relative 'openstudio-standards/create_typical/space_type_blend'
|
37
|
+
|
38
|
+
# QAQC Module
|
39
|
+
require_relative 'openstudio-standards/qaqc/calibration'
|
40
|
+
require_relative 'openstudio-standards/qaqc/envelope'
|
41
|
+
require_relative 'openstudio-standards/qaqc/eui'
|
42
|
+
require_relative 'openstudio-standards/qaqc/hvac'
|
43
|
+
require_relative 'openstudio-standards/qaqc/internal_loads'
|
44
|
+
require_relative 'openstudio-standards/qaqc/schedules'
|
45
|
+
require_relative 'openstudio-standards/qaqc/service_water_heating'
|
46
|
+
require_relative 'openstudio-standards/qaqc/weather_files'
|
47
|
+
require_relative 'openstudio-standards/qaqc/zone_conditions'
|
48
|
+
require_relative 'openstudio-standards/qaqc/create_results'
|
49
|
+
require_relative 'openstudio-standards/qaqc/reporting'
|
50
|
+
|
51
|
+
# Weather Module
|
52
|
+
require_relative 'openstudio-standards/weather/information'
|
10
53
|
|
11
54
|
# Weather data
|
12
55
|
require_relative 'openstudio-standards/weather/Weather.Model'
|
@@ -25,6 +68,7 @@ module OpenstudioStandards
|
|
25
68
|
require_relative 'openstudio-standards/utilities/schedule_translator'
|
26
69
|
require_relative 'openstudio-standards/utilities/array'
|
27
70
|
require_relative 'openstudio-standards/utilities/object_info'
|
71
|
+
require_relative 'openstudio-standards/utilities/assertion'
|
28
72
|
|
29
73
|
stds = 'openstudio-standards/standards'
|
30
74
|
proto = 'openstudio-standards/prototypes'
|
@@ -282,13 +326,14 @@ module OpenstudioStandards
|
|
282
326
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas"
|
283
327
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater"
|
284
328
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR"
|
285
|
-
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower"
|
286
|
-
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed"
|
287
329
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat"
|
288
330
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface"
|
289
331
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone"
|
290
332
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType"
|
291
333
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.Surface"
|
334
|
+
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir"
|
335
|
+
require_relative "#{stds}/ashrae_90_1_prm/userdata_csv/userdata_enums.rb"
|
336
|
+
require_relative "#{stds}/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData"
|
292
337
|
|
293
338
|
# 90.1-PRM-2019
|
294
339
|
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019"
|
@@ -354,6 +399,26 @@ module OpenstudioStandards
|
|
354
399
|
require_relative "#{stds}/deer/deer.AirLoopHVAC"
|
355
400
|
require_relative "#{stds}/deer/deer.Space"
|
356
401
|
require_relative "#{stds}/deer/deer.PlanarSurface"
|
402
|
+
# DEER 2003
|
403
|
+
require_relative "#{stds}/deer/deer_2003/deer_2003.ThermalZone"
|
404
|
+
# DEER 2007
|
405
|
+
require_relative "#{stds}/deer/deer_2007/deer_2007.ThermalZone"
|
406
|
+
# DEER 2011
|
407
|
+
require_relative "#{stds}/deer/deer_2011/deer_2011.ThermalZone"
|
408
|
+
# DEER 2014
|
409
|
+
require_relative "#{stds}/deer/deer_2014/deer_2014.Space"
|
410
|
+
require_relative "#{stds}/deer/deer_2014/deer_2014.ThermalZone"
|
411
|
+
# DEER 2015
|
412
|
+
require_relative "#{stds}/deer/deer_2015/deer_2015.Space"
|
413
|
+
require_relative "#{stds}/deer/deer_2015/deer_2015.ThermalZone"
|
414
|
+
# DEER 2017
|
415
|
+
require_relative "#{stds}/deer/deer_2017/deer_2017.Space"
|
416
|
+
require_relative "#{stds}/deer/deer_2017/deer_2017.ThermalZone"
|
417
|
+
# DEER 2020
|
418
|
+
require_relative "#{stds}/deer/deer_2020/deer_2020.AirLoopHVAC"
|
419
|
+
require_relative "#{stds}/deer/deer_2020/deer_2020.FanVariableVolume"
|
420
|
+
require_relative "#{stds}/deer/deer_2020/deer_2020.Space"
|
421
|
+
require_relative "#{stds}/deer/deer_2020/deer_2020.ThermalZone"
|
357
422
|
# CBES Common
|
358
423
|
require_relative "#{stds}/cbes/cbes.AirLoopHVAC"
|
359
424
|
require_relative "#{stds}/cbes/cbes.Model"
|
@@ -497,7 +562,6 @@ module OpenstudioStandards
|
|
497
562
|
require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff"
|
498
563
|
require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume"
|
499
564
|
require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent"
|
500
|
-
require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model"
|
501
565
|
require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators"
|
502
566
|
require_relative "#{proto}/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems"
|
503
567
|
# ZE AEDG Multifamily
|
metadata
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
--- !ruby/object:Gem::Specification
|
2
2
|
name: openstudio-standards
|
3
3
|
version: !ruby/object:Gem::Version
|
4
|
-
version: 0.
|
4
|
+
version: 0.5.0.rc1
|
5
5
|
platform: ruby
|
6
6
|
authors:
|
7
7
|
- Andrew Parker
|
@@ -25,25 +25,26 @@ authors:
|
|
25
25
|
- Xuechen (Jerry) Lei
|
26
26
|
- Juan Gonzalez Matamoros
|
27
27
|
- Jeremy Lerond
|
28
|
+
- Carlos Duarte
|
28
29
|
autorequire:
|
29
30
|
bindir: bin
|
30
31
|
cert_chain: []
|
31
|
-
date: 2023-
|
32
|
+
date: 2023-10-13 00:00:00.000000000 Z
|
32
33
|
dependencies:
|
33
34
|
- !ruby/object:Gem::Dependency
|
34
35
|
name: minitest-reporters
|
35
36
|
requirement: !ruby/object:Gem::Requirement
|
36
37
|
requirements:
|
37
|
-
- -
|
38
|
+
- - '='
|
38
39
|
- !ruby/object:Gem::Version
|
39
|
-
version:
|
40
|
+
version: 1.6.1
|
40
41
|
type: :development
|
41
42
|
prerelease: false
|
42
43
|
version_requirements: !ruby/object:Gem::Requirement
|
43
44
|
requirements:
|
44
|
-
- -
|
45
|
+
- - '='
|
45
46
|
- !ruby/object:Gem::Version
|
46
|
-
version:
|
47
|
+
version: 1.6.1
|
47
48
|
- !ruby/object:Gem::Dependency
|
48
49
|
name: minitest-parallel_fork
|
49
50
|
requirement: !ruby/object:Gem::Requirement
|
@@ -625,7 +626,8 @@ files:
|
|
625
626
|
- data/geometry/DOERefSmallOffice.json
|
626
627
|
- data/geometry/DOERefWarehouse.json
|
627
628
|
- data/geometry/DOERefWarehouse.osm
|
628
|
-
- data/
|
629
|
+
- data/inventory/thermal_bridging.csv
|
630
|
+
- data/standards/OpenStudio_Standards-deer-comstock.xlsx
|
629
631
|
- data/standards/exclude_list.csv
|
630
632
|
- data/standards/export_OpenStudio_libraries.rb
|
631
633
|
- data/standards/legacy_dd_results.csv
|
@@ -1349,12 +1351,21 @@ files:
|
|
1349
1351
|
- lib/openstudio-standards/btap/utilities/weatherData1_xlsx_to_json.rb
|
1350
1352
|
- lib/openstudio-standards/btap/vintagizer.rb
|
1351
1353
|
- lib/openstudio-standards/btap/visualization.rb
|
1352
|
-
- lib/openstudio-standards/
|
1353
|
-
- lib/openstudio-standards/
|
1354
|
-
- lib/openstudio-standards/
|
1355
|
-
- lib/openstudio-standards/
|
1356
|
-
- lib/openstudio-standards/
|
1357
|
-
- lib/openstudio-standards/
|
1354
|
+
- lib/openstudio-standards/constructions/information.rb
|
1355
|
+
- lib/openstudio-standards/constructions/materials/modify.rb
|
1356
|
+
- lib/openstudio-standards/constructions/modify.rb
|
1357
|
+
- lib/openstudio-standards/create_typical/create_typical.rb
|
1358
|
+
- lib/openstudio-standards/create_typical/enumerations.rb
|
1359
|
+
- lib/openstudio-standards/create_typical/space_type_blend.rb
|
1360
|
+
- lib/openstudio-standards/create_typical/space_type_ratios.rb
|
1361
|
+
- lib/openstudio-standards/daylighting/space.rb
|
1362
|
+
- lib/openstudio-standards/geometry/create.rb
|
1363
|
+
- lib/openstudio-standards/geometry/create_bar.rb
|
1364
|
+
- lib/openstudio-standards/geometry/information.rb
|
1365
|
+
- lib/openstudio-standards/geometry/modify.rb
|
1366
|
+
- lib/openstudio-standards/hvac/air_loop/information.rb
|
1367
|
+
- lib/openstudio-standards/hvac/cbecs_hvac.rb
|
1368
|
+
- lib/openstudio-standards/hvac/setpoint_managers/information.rb
|
1358
1369
|
- lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb
|
1359
1370
|
- lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PumpVariableSpeed.rb
|
1360
1371
|
- lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb
|
@@ -1408,7 +1419,6 @@ files:
|
|
1408
1419
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb
|
1409
1420
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb
|
1410
1421
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
|
1411
|
-
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb
|
1412
1422
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb
|
1413
1423
|
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb
|
1414
1424
|
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb
|
@@ -1490,7 +1500,21 @@ files:
|
|
1490
1500
|
- lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb
|
1491
1501
|
- lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb
|
1492
1502
|
- lib/openstudio-standards/prototypes/deer/deer.Model.rb
|
1503
|
+
- lib/openstudio-standards/qaqc/calibration.rb
|
1504
|
+
- lib/openstudio-standards/qaqc/create_results.rb
|
1505
|
+
- lib/openstudio-standards/qaqc/envelope.rb
|
1506
|
+
- lib/openstudio-standards/qaqc/eui.rb
|
1507
|
+
- lib/openstudio-standards/qaqc/hvac.rb
|
1508
|
+
- lib/openstudio-standards/qaqc/internal_loads.rb
|
1509
|
+
- lib/openstudio-standards/qaqc/reporting.rb
|
1510
|
+
- lib/openstudio-standards/qaqc/schedules.rb
|
1511
|
+
- lib/openstudio-standards/qaqc/service_water_heating.rb
|
1512
|
+
- lib/openstudio-standards/qaqc/weather_files.rb
|
1513
|
+
- lib/openstudio-standards/qaqc/zone_conditions.rb
|
1493
1514
|
- lib/openstudio-standards/refs/references.rb
|
1515
|
+
- lib/openstudio-standards/schedules/create.rb
|
1516
|
+
- lib/openstudio-standards/schedules/information.rb
|
1517
|
+
- lib/openstudio-standards/schedules/modify.rb
|
1494
1518
|
- lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb
|
1495
1519
|
- lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb
|
1496
1520
|
- lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb
|
@@ -1714,6 +1738,7 @@ files:
|
|
1714
1738
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ThermalZone.rb
|
1715
1739
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb
|
1716
1740
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.rb
|
1741
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb
|
1717
1742
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.rb
|
1718
1743
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/ashrae_90_1.schedules.json
|
1719
1744
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/data/comstock_ashrae_90_1_2016.ext_ltg.json
|
@@ -1756,6 +1781,7 @@ files:
|
|
1756
1781
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ThermalZone.rb
|
1757
1782
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb
|
1758
1783
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.rb
|
1784
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb
|
1759
1785
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.rb
|
1760
1786
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/ashrae_90_1.schedules.json
|
1761
1787
|
- lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/data/comstock_ashrae_90_1_2019.ext_ltg.json
|
@@ -1946,8 +1972,7 @@ files:
|
|
1946
1972
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb
|
1947
1973
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb
|
1948
1974
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb
|
1949
|
-
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.
|
1950
|
-
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb
|
1975
|
+
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb
|
1951
1976
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Fan.rb
|
1952
1977
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb
|
1953
1978
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb
|
@@ -1992,6 +2017,7 @@ files:
|
|
1992
2017
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.fans.json
|
1993
2018
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/data/ashrae_90_1_prm.materials.json
|
1994
2019
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_building_rotation_exception.md
|
2020
|
+
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md
|
1995
2021
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/check_pump_power_and_control.md
|
1996
2022
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/dcv.md
|
1997
2023
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/dcv_implementation.png
|
@@ -2011,11 +2037,13 @@ files:
|
|
2011
2037
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/unmet_load_hours.md
|
2012
2038
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/vav_parallel_piu_terminals_fan_control.md
|
2013
2039
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/docs/vav_terminals_min_flow_setpoint.md
|
2040
|
+
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb
|
2014
2041
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_airloop_hvac.csv
|
2015
2042
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_airloop_hvac_doas.csv
|
2016
2043
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_building.csv
|
2017
2044
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_design_specification_outdoor_air.csv
|
2018
2045
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_electric_equipment.csv
|
2046
|
+
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb
|
2019
2047
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_exterior_lights.csv
|
2020
2048
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_gas_equipment.csv
|
2021
2049
|
- lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_lights.csv
|
@@ -2512,6 +2540,7 @@ files:
|
|
2512
2540
|
- lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.chillers.json
|
2513
2541
|
- lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.construction_properties.json
|
2514
2542
|
- lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.construction_sets.json
|
2543
|
+
- lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json
|
2515
2544
|
- lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.elevators.json
|
2516
2545
|
- lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.ext_ltg.json
|
2517
2546
|
- lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.heat_pumps.json
|
@@ -2748,6 +2777,8 @@ files:
|
|
2748
2777
|
- lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb
|
2749
2778
|
- lib/openstudio-standards/standards/necb/ECMS/data/boiler_set.json
|
2750
2779
|
- lib/openstudio-standards/standards/necb/ECMS/data/chiller_set.json
|
2780
|
+
- lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json
|
2781
|
+
- lib/openstudio-standards/standards/necb/ECMS/data/chillers.json
|
2751
2782
|
- lib/openstudio-standards/standards/necb/ECMS/data/curves.json
|
2752
2783
|
- lib/openstudio-standards/standards/necb/ECMS/data/equip_eff_lim.json
|
2753
2784
|
- lib/openstudio-standards/standards/necb/ECMS/data/erv.json
|
@@ -2767,6 +2798,7 @@ files:
|
|
2767
2798
|
- lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb
|
2768
2799
|
- lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb
|
2769
2800
|
- lib/openstudio-standards/standards/necb/NECB2011/data/boilers.json
|
2801
|
+
- lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json
|
2770
2802
|
- lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json
|
2771
2803
|
- lib/openstudio-standards/standards/necb/NECB2011/data/climate_zone_sets.json
|
2772
2804
|
- lib/openstudio-standards/standards/necb/NECB2011/data/constants.json
|
@@ -2783,6 +2815,8 @@ files:
|
|
2783
2815
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LowriseApartment.osm
|
2784
2816
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/MediumOffice.osm
|
2785
2817
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/MidriseApartment.osm
|
2818
|
+
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm
|
2819
|
+
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm
|
2786
2820
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Outpatient.osm
|
2787
2821
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/PrimarySchool.osm
|
2788
2822
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/QuickServiceRestaurant.osm
|
@@ -2891,6 +2925,7 @@ files:
|
|
2891
2925
|
- lib/openstudio-standards/standards/oeesc/oeesc_2014/oeesc_2014.rb
|
2892
2926
|
- lib/openstudio-standards/standards/standard.rb
|
2893
2927
|
- lib/openstudio-standards/utilities/array.rb
|
2928
|
+
- lib/openstudio-standards/utilities/assertion.rb
|
2894
2929
|
- lib/openstudio-standards/utilities/define_thermal_zone_and_mulitpliers.rb
|
2895
2930
|
- lib/openstudio-standards/utilities/delete_all_objs_except_geo.rb
|
2896
2931
|
- lib/openstudio-standards/utilities/generate_prototype_database.rb
|
@@ -2908,6 +2943,7 @@ files:
|
|
2908
2943
|
- lib/openstudio-standards/version.rb
|
2909
2944
|
- lib/openstudio-standards/weather/Weather.Model.rb
|
2910
2945
|
- lib/openstudio-standards/weather/Weather.stat_file.rb
|
2946
|
+
- lib/openstudio-standards/weather/information.rb
|
2911
2947
|
homepage: http://openstudio.net
|
2912
2948
|
licenses:
|
2913
2949
|
- LGPL
|
Binary file
|
@@ -1,59 +0,0 @@
|
|
1
|
-
|
2
|
-
# Reopen the OpenStudio class to add methods to apply standards to this object
|
3
|
-
class OpenStudio::Model::AirLoopHVAC
|
4
|
-
|
5
|
-
# Retrieves an airloop sum of air terminal minimum heating flow rates: sum(Vpz_min)
|
6
|
-
def autosizeSumMinimumHeatingAirFlowRates
|
7
|
-
result = OpenStudio::OptionalDouble.new
|
8
|
-
name = self.name.get.upcase
|
9
|
-
sql = self.model.sqlFile
|
10
|
-
if sql.is_initialized
|
11
|
-
sql = sql.get
|
12
|
-
query = "SELECT Value
|
13
|
-
FROM tabulardatawithstrings
|
14
|
-
WHERE ReportName='ComponentSizingSummary'
|
15
|
-
AND ReportForString='Entire Facility'
|
16
|
-
AND TableName='AirLoopHVAC'
|
17
|
-
AND ColumnName='Sum of Air Terminal Minimum Heating Flow Rates'
|
18
|
-
AND RowName='#{name}'
|
19
|
-
AND Units='m3/s'"
|
20
|
-
val = sql.execAndReturnFirstDouble(query)
|
21
|
-
if val.is_initialized
|
22
|
-
result = OpenStudio::OptionalDouble.new(val.get)
|
23
|
-
end
|
24
|
-
else
|
25
|
-
OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Model has no sql file containing results, cannot lookup data.')
|
26
|
-
end
|
27
|
-
|
28
|
-
return result.to_f
|
29
|
-
|
30
|
-
end
|
31
|
-
|
32
|
-
# Retrieve an airloop's sum of air terminal maximum flow rates: sum(Vpz)
|
33
|
-
def autosizeSumAirTerminalMaxAirFlowRate
|
34
|
-
result = OpenStudio::OptionalDouble.new
|
35
|
-
name = self.name.get.upcase
|
36
|
-
sql = self.model.sqlFile
|
37
|
-
if sql.is_initialized
|
38
|
-
sql = sql.get
|
39
|
-
query = "SELECT Value
|
40
|
-
FROM tabulardatawithstrings
|
41
|
-
WHERE ReportName='ComponentSizingSummary'
|
42
|
-
AND ReportForString='Entire Facility'
|
43
|
-
AND TableName='AirLoopHVAC'
|
44
|
-
AND ColumnName='Sum of Air Terminal Maximum Flow Rates'
|
45
|
-
AND RowName='#{name}'
|
46
|
-
AND Units='m3/s'"
|
47
|
-
val = sql.execAndReturnFirstDouble(query)
|
48
|
-
if val.is_initialized
|
49
|
-
result = OpenStudio::OptionalDouble.new(val.get)
|
50
|
-
end
|
51
|
-
else
|
52
|
-
OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Model has no sql file containing results, cannot lookup data.')
|
53
|
-
end
|
54
|
-
|
55
|
-
return result.to_f
|
56
|
-
|
57
|
-
end
|
58
|
-
|
59
|
-
end
|
@@ -1,13 +0,0 @@
|
|
1
|
-
|
2
|
-
# open the class to add methods to return sizing values
|
3
|
-
class OpenStudio::Model::CoilCoolingWater
|
4
|
-
|
5
|
-
# returns the autosized design coil load
|
6
|
-
def autosizedDesignCoilLoad
|
7
|
-
|
8
|
-
return self.getAutosizedValue('Design Size Design Coil Load', 'W')
|
9
|
-
|
10
|
-
end
|
11
|
-
|
12
|
-
|
13
|
-
end
|
@@ -1,36 +0,0 @@
|
|
1
|
-
|
2
|
-
###### IMPORTANT NOTE ######
|
3
|
-
# These methods should be done via extension to OS model objects
|
4
|
-
# directly in the C++ SDK.
|
5
|
-
###### IMPORTANT NOTE ######
|
6
|
-
|
7
|
-
class OpenStudio::Model::HVACComponent
|
8
|
-
# Returns the number of individual pieces of equipment
|
9
|
-
# represented by a particular HVAC component. Pulls from
|
10
|
-
# the additionalProperties object attached to the component.
|
11
|
-
# This can be used during the application of efficiency
|
12
|
-
# levels that are based on component capacities, flowrates, etc.
|
13
|
-
# @return [Integer] the number of components, 1 if not set
|
14
|
-
def component_quantity
|
15
|
-
addl_props = self.additionalProperties
|
16
|
-
if addl_props.getFeatureAsInteger('component_quantity').is_initialized
|
17
|
-
comp_qty = addl_props.getFeatureAsInteger('component_quantity').get
|
18
|
-
else
|
19
|
-
comp_qty = 1
|
20
|
-
end
|
21
|
-
|
22
|
-
return comp_qty
|
23
|
-
end
|
24
|
-
|
25
|
-
# Sets the number of individual pieces of equipment
|
26
|
-
# represented by a particular HVAC component. Uses the
|
27
|
-
# additionalProperties object attached to the component.
|
28
|
-
# This can be used during the application of efficiency
|
29
|
-
# levels that are based on component capacities, flowrates, etc.
|
30
|
-
# @param comp_qty [Integer] the number of individual pieces of equipment
|
31
|
-
# represented by this HVAC component
|
32
|
-
# @return [Bool] returns true if successful, false if not
|
33
|
-
def set_component_quantity(comp_qty)
|
34
|
-
return self.additionalProperties.setFeature('component_quantity', comp_qty)
|
35
|
-
end
|
36
|
-
end
|