openstudio-standards 0.4.0 → 0.5.0.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/inventory/thermal_bridging.csv +90 -0
- data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
- data/lib/openstudio-standards/btap/analysis.rb +8 -8
- data/lib/openstudio-standards/btap/bridging.rb +664 -645
- data/lib/openstudio-standards/btap/btap.model.rb +14 -14
- data/lib/openstudio-standards/btap/btap.rb +7 -7
- data/lib/openstudio-standards/btap/btap_result.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +23 -23
- data/lib/openstudio-standards/btap/envelope.rb +8 -8
- data/lib/openstudio-standards/btap/equest.rb +1 -1
- data/lib/openstudio-standards/btap/geometry.rb +2 -2
- data/lib/openstudio-standards/btap/mpc.rb +7 -7
- data/lib/openstudio-standards/btap/schedules.rb +1 -1
- data/lib/openstudio-standards/btap/simmanager.rb +4 -4
- data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
- data/lib/openstudio-standards/btap/utilities.rb +6 -6
- data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
- data/lib/openstudio-standards/constructions/information.rb +83 -0
- data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
- data/lib/openstudio-standards/constructions/modify.rb +80 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
- data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
- data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
- data/lib/openstudio-standards/daylighting/space.rb +47 -0
- data/lib/openstudio-standards/geometry/create.rb +801 -0
- data/lib/openstudio-standards/geometry/create_bar.rb +2171 -0
- data/lib/openstudio-standards/geometry/information.rb +462 -0
- data/lib/openstudio-standards/geometry/modify.rb +48 -0
- data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
- data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
- data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
- data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
- data/lib/openstudio-standards/qaqc/eui.rb +213 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
- data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
- data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
- data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
- data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
- data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
- data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
- data/lib/openstudio-standards/schedules/create.rb +364 -0
- data/lib/openstudio-standards/schedules/information.rb +169 -0
- data/lib/openstudio-standards/schedules/modify.rb +445 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
- data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
- data/lib/openstudio-standards/utilities/assertion.rb +128 -0
- data/lib/openstudio-standards/utilities/logging.rb +2 -3
- data/lib/openstudio-standards/utilities/object_info.rb +39 -18
- data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
- data/lib/openstudio-standards/utilities/simulation.rb +24 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
- data/lib/openstudio-standards/weather/information.rb +35 -0
- data/lib/openstudio-standards.rb +69 -5
- metadata +52 -16
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -6,7 +6,7 @@ class Standard
|
|
6
6
|
# Hard-size the resulting min OA into the sizing:system object.
|
7
7
|
#
|
8
8
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
9
|
-
# return [
|
9
|
+
# return [Boolean] returns true if successful, false if not
|
10
10
|
# @todo move building-type-specific code to Prototype classes
|
11
11
|
def air_loop_hvac_apply_multizone_vav_outdoor_air_sizing(air_loop_hvac)
|
12
12
|
# First time adjustment:
|
@@ -25,7 +25,7 @@ class Standard
|
|
25
25
|
#
|
26
26
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
27
27
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
28
|
-
# @return [
|
28
|
+
# @return [Boolean] returns true if successful, false if not
|
29
29
|
# @todo optimum start
|
30
30
|
# @todo night damper shutoff
|
31
31
|
# @todo nightcycle control
|
@@ -190,7 +190,7 @@ class Standard
|
|
190
190
|
#
|
191
191
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
192
192
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
193
|
-
# @return [
|
193
|
+
# @return [Boolean] returns true if successful, false if not
|
194
194
|
def air_loop_hvac_apply_prm_baseline_controls(air_loop_hvac, climate_zone)
|
195
195
|
# Economizers
|
196
196
|
if air_loop_hvac_prm_baseline_economizer_required?(air_loop_hvac, climate_zone)
|
@@ -233,7 +233,7 @@ class Standard
|
|
233
233
|
# Defaults to 90.1-2004 logic, which requires optimum start if > 10,000 cfm
|
234
234
|
#
|
235
235
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
236
|
-
# @return [
|
236
|
+
# @return [Boolean] returns true if required, false if not
|
237
237
|
def air_loop_hvac_optimum_start_required?(air_loop_hvac)
|
238
238
|
opt_start_required = false
|
239
239
|
|
@@ -268,7 +268,7 @@ class Standard
|
|
268
268
|
# Adds optimum start control to the airloop.
|
269
269
|
#
|
270
270
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
271
|
-
# @return [
|
271
|
+
# @return [Boolean] returns true if successful, false if not
|
272
272
|
def air_loop_hvac_enable_optimum_start(air_loop_hvac)
|
273
273
|
# Get the heating and cooling setpoint schedules
|
274
274
|
# for all zones on this airloop.
|
@@ -374,7 +374,7 @@ class Standard
|
|
374
374
|
end
|
375
375
|
|
376
376
|
# Set default fan curve to be VSD with static pressure reset
|
377
|
-
# @return [
|
377
|
+
# @return [String name of appropriate curve for this code version
|
378
378
|
def air_loop_hvac_set_vsd_curve_type
|
379
379
|
return 'Multi Zone VAV with VSD and SP Setpoint Reset'
|
380
380
|
end
|
@@ -387,7 +387,7 @@ class Standard
|
|
387
387
|
# if the proposed model had multiple fans (supply, return, exhaust, etc.)
|
388
388
|
#
|
389
389
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
390
|
-
# return [
|
390
|
+
# return [Boolean] true if successful, false if not
|
391
391
|
def air_loop_hvac_apply_prm_baseline_fan_power(air_loop_hvac)
|
392
392
|
# Main AHU fans
|
393
393
|
|
@@ -625,7 +625,7 @@ class Standard
|
|
625
625
|
# with or without the fans inside of fan powered terminals.
|
626
626
|
#
|
627
627
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
628
|
-
# @param include_terminal_fans [
|
628
|
+
# @param include_terminal_fans [Boolean] if true, power from fan powered terminals will be included
|
629
629
|
# @return [Double] total brake horsepower of the fans on the system, in units of horsepower
|
630
630
|
def air_loop_hvac_system_fan_brake_horsepower(air_loop_hvac, include_terminal_fans = true)
|
631
631
|
# @todo get the template from the parent model itself?
|
@@ -668,7 +668,7 @@ class Standard
|
|
668
668
|
# the system hitting the baseline allowable fan power
|
669
669
|
#
|
670
670
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
671
|
-
# @return [
|
671
|
+
# @return [Boolean] returns true if successful, false if not
|
672
672
|
def air_loop_hvac_apply_baseline_fan_pressure_rise(air_loop_hvac)
|
673
673
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "#{air_loop_hvac.name}-Setting #{template} baseline fan power.")
|
674
674
|
|
@@ -784,6 +784,10 @@ class Standard
|
|
784
784
|
# CoilCoolingWater
|
785
785
|
elsif sc.to_CoilCoolingWater.is_initialized
|
786
786
|
coil = sc.to_CoilCoolingWater.get
|
787
|
+
# error if the design coil capacity method isn't available
|
788
|
+
if coil.model.version < OpenStudio::VersionString.new('3.6.0')
|
789
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', 'Required CoilCoolingWater method .autosizedDesignCoilLoad is not available in pre-OpenStudio 3.6.0 versions. Use a more recent version of OpenStudio.')
|
790
|
+
end
|
787
791
|
if coil.autosizedDesignCoilLoad.is_initialized
|
788
792
|
# @todo Change to pull water coil nominal capacity instead of design load
|
789
793
|
total_cooling_capacity_w += coil.autosizedDesignCoilLoad.get
|
@@ -827,6 +831,10 @@ class Standard
|
|
827
831
|
# CoilCoolingWater
|
828
832
|
elsif clg_coil.to_CoilCoolingWater.is_initialized
|
829
833
|
coil = clg_coil.to_CoilCoolingWater.get
|
834
|
+
# error if the design coil capacity method isn't available
|
835
|
+
if coil.model.version < OpenStudio::VersionString.new('3.6.0')
|
836
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', 'Required CoilCoolingWater method .autosizedDesignCoilLoad is not available in pre-OpenStudio 3.6.0 versions. Use a more recent version of OpenStudio.')
|
837
|
+
end
|
830
838
|
if coil.autosizedDesignCoilLoad.is_initialized
|
831
839
|
# @todo Change to pull water coil nominal capacity instead of design load
|
832
840
|
total_cooling_capacity_w += coil.autosizedDesignCoilLoad.get
|
@@ -871,6 +879,10 @@ class Standard
|
|
871
879
|
# CoilCoolingWater
|
872
880
|
elsif clg_coil.to_CoilCoolingWater.is_initialized
|
873
881
|
coil = clg_coil.to_CoilCoolingWater.get
|
882
|
+
# error if the design coil capacity method isn't available
|
883
|
+
if coil.model.version < OpenStudio::VersionString.new('3.6.0')
|
884
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', 'Required CoilCoolingWater method .autosizedDesignCoilLoad is not available in pre-OpenStudio 3.6.0 versions. Use a more recent version of OpenStudio.')
|
885
|
+
end
|
874
886
|
if coil.autosizedDesignCoilLoad.is_initialized
|
875
887
|
# @todo Change to pull water coil nominal capacity instead of design load
|
876
888
|
total_cooling_capacity_w += coil.autosizedDesignCoilLoad.get
|
@@ -937,7 +949,7 @@ class Standard
|
|
937
949
|
#
|
938
950
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
939
951
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
940
|
-
# @return [
|
952
|
+
# @return [Boolean] returns true if an economizer is required, false if not
|
941
953
|
def air_loop_hvac_economizer_required?(air_loop_hvac, climate_zone)
|
942
954
|
economizer_required = false
|
943
955
|
|
@@ -1013,7 +1025,7 @@ class Standard
|
|
1013
1025
|
#
|
1014
1026
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1015
1027
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1016
|
-
# @return [
|
1028
|
+
# @return [Boolean] returns true if successful, false if not
|
1017
1029
|
def air_loop_hvac_apply_economizer_limits(air_loop_hvac, climate_zone)
|
1018
1030
|
# EnergyPlus economizer types
|
1019
1031
|
# 'NoEconomizer'
|
@@ -1060,6 +1072,12 @@ class Standard
|
|
1060
1072
|
oa_control.setEconomizerMaximumLimitDryBulbTemperature(drybulb_limit_c)
|
1061
1073
|
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Economizer type = #{economizer_type}, dry bulb limit = #{drybulb_limit_f}F")
|
1062
1074
|
end
|
1075
|
+
# Some templates include fixed enthalpy limits in addition to fixed dry bulb limits
|
1076
|
+
if enthalpy_limit_btu_per_lb
|
1077
|
+
enthalpy_limit_j_per_kg = OpenStudio.convert(enthalpy_limit_btu_per_lb, 'Btu/lb', 'J/kg').get
|
1078
|
+
oa_control.setEconomizerMaximumLimitEnthalpy(enthalpy_limit_j_per_kg)
|
1079
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: additional economizer enthalpy limit = #{enthalpy_limit_btu_per_lb}Btu/lb")
|
1080
|
+
end
|
1063
1081
|
when 'FixedEnthalpy'
|
1064
1082
|
if enthalpy_limit_btu_per_lb
|
1065
1083
|
enthalpy_limit_j_per_kg = OpenStudio.convert(enthalpy_limit_btu_per_lb, 'Btu/lb', 'J/kg').get
|
@@ -1123,7 +1141,7 @@ class Standard
|
|
1123
1141
|
#
|
1124
1142
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1125
1143
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1126
|
-
# @return [
|
1144
|
+
# @return [Boolean] returns true if successful, false if not
|
1127
1145
|
def air_loop_hvac_apply_economizer_integration(air_loop_hvac, climate_zone)
|
1128
1146
|
# Determine if an integrated economizer is required
|
1129
1147
|
integrated_economizer_required = air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
|
@@ -1158,7 +1176,7 @@ class Standard
|
|
1158
1176
|
# Determine if the airloop includes hydronic cooling coils
|
1159
1177
|
#
|
1160
1178
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1161
|
-
# @return [
|
1179
|
+
# @return [Boolean] returns true if hydronic cooling coils are included on the airloop
|
1162
1180
|
def air_loop_hvac_include_hydronic_cooling_coil?(air_loop_hvac)
|
1163
1181
|
air_loop_hvac.supplyComponents.each do |comp|
|
1164
1182
|
return true if comp.to_CoilCoolingWater.is_initialized
|
@@ -1168,7 +1186,7 @@ class Standard
|
|
1168
1186
|
|
1169
1187
|
# Determine if the airloop includes cooling coils
|
1170
1188
|
#
|
1171
|
-
# @return [
|
1189
|
+
# @return [Boolean] returns true if cooling coils are included on the airloop
|
1172
1190
|
def air_loop_hvac_include_cooling_coil?(air_loop_hvac)
|
1173
1191
|
air_loop_hvac.supplyComponents.each do |comp|
|
1174
1192
|
return true if comp.to_CoilCoolingWater.is_initialized
|
@@ -1214,7 +1232,7 @@ class Standard
|
|
1214
1232
|
|
1215
1233
|
# Determine if the airloop includes evaporative coolers
|
1216
1234
|
#
|
1217
|
-
# @return [
|
1235
|
+
# @return [Boolean] returns true if evaporative coolers are included on the airloop
|
1218
1236
|
def air_loop_hvac_include_evaporative_cooler?(air_loop_hvac)
|
1219
1237
|
air_loop_hvac.supplyComponents.each do |comp|
|
1220
1238
|
return true if comp.to_EvaporativeCoolerDirectResearchSpecial.is_initialized
|
@@ -1225,7 +1243,7 @@ class Standard
|
|
1225
1243
|
|
1226
1244
|
# Determine if the airloop includes an air-economizer
|
1227
1245
|
#
|
1228
|
-
# @return [
|
1246
|
+
# @return [Boolean] returns true if the airloop has an air-economizer
|
1229
1247
|
def air_loop_hvac_include_economizer?(air_loop_hvac)
|
1230
1248
|
return false unless air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
1231
1249
|
|
@@ -1245,7 +1263,7 @@ class Standard
|
|
1245
1263
|
# Determine if the airloop includes WSHP cooling coils
|
1246
1264
|
#
|
1247
1265
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1248
|
-
# @return [
|
1266
|
+
# @return [Boolean] returns true if WSHP cooling coils are included on the airloop
|
1249
1267
|
def air_loop_hvac_include_wshp?(air_loop_hvac)
|
1250
1268
|
air_loop_hvac.supplyComponents.each do |comp|
|
1251
1269
|
return true if comp.to_CoilCoolingWaterToAirHeatPumpEquationFit.is_initialized
|
@@ -1261,7 +1279,7 @@ class Standard
|
|
1261
1279
|
|
1262
1280
|
# Determine if the air loop includes a unitary system
|
1263
1281
|
#
|
1264
|
-
# @return [
|
1282
|
+
# @return [Boolean] returns true if a unitary system is included on the air loop
|
1265
1283
|
def air_loop_hvac_include_unitary_system?(air_loop_hvac)
|
1266
1284
|
air_loop_hvac.supplyComponents.each do |comp|
|
1267
1285
|
return true if comp.to_AirLoopHVACUnitarySystem.is_initialized
|
@@ -1275,7 +1293,7 @@ class Standard
|
|
1275
1293
|
#
|
1276
1294
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1277
1295
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1278
|
-
# @return [
|
1296
|
+
# @return [Boolean] returns true if required, false if not
|
1279
1297
|
def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
|
1280
1298
|
# Determine if it is a VAV system
|
1281
1299
|
is_vav = air_loop_hvac_vav_system?(air_loop_hvac)
|
@@ -1353,7 +1371,7 @@ class Standard
|
|
1353
1371
|
#
|
1354
1372
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1355
1373
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1356
|
-
# @return [
|
1374
|
+
# @return [Boolean] returns true if required, false if not
|
1357
1375
|
def air_loop_hvac_prm_baseline_economizer_required?(air_loop_hvac, climate_zone)
|
1358
1376
|
economizer_required = false
|
1359
1377
|
|
@@ -1415,7 +1433,7 @@ class Standard
|
|
1415
1433
|
#
|
1416
1434
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1417
1435
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1418
|
-
# @return [
|
1436
|
+
# @return [Boolean] returns true if successful, false if not
|
1419
1437
|
def air_loop_hvac_apply_prm_baseline_economizer(air_loop_hvac, climate_zone)
|
1420
1438
|
# EnergyPlus economizer types
|
1421
1439
|
# 'NoEconomizer'
|
@@ -1535,7 +1553,7 @@ class Standard
|
|
1535
1553
|
#
|
1536
1554
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1537
1555
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1538
|
-
# @return [
|
1556
|
+
# @return [Boolean] returns true if allowable, if the system has no economizer or no OA system
|
1539
1557
|
# Returns false if the economizer type is not allowable.
|
1540
1558
|
def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
|
1541
1559
|
# EnergyPlus economizer types
|
@@ -1620,7 +1638,7 @@ class Standard
|
|
1620
1638
|
#
|
1621
1639
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1622
1640
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1623
|
-
# @return [
|
1641
|
+
# @return [Boolean] returns true if required, false if not
|
1624
1642
|
# @todo Add exception logic for systems serving parking garage, warehouse, or multifamily
|
1625
1643
|
def air_loop_hvac_energy_recovery_ventilator_required?(air_loop_hvac, climate_zone)
|
1626
1644
|
# ERV Not Applicable for AHUs that serve
|
@@ -1780,7 +1798,7 @@ class Standard
|
|
1780
1798
|
#
|
1781
1799
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1782
1800
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1783
|
-
# @return [
|
1801
|
+
# @return [Boolean] returns true if required, false if not
|
1784
1802
|
# @todo Add exception logic for systems serving parking garage, warehouse, or multifamily
|
1785
1803
|
def air_loop_hvac_apply_energy_recovery_ventilator(air_loop_hvac, climate_zone)
|
1786
1804
|
# Get the OA system
|
@@ -1892,7 +1910,7 @@ class Standard
|
|
1892
1910
|
#
|
1893
1911
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1894
1912
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
1895
|
-
# @return [
|
1913
|
+
# @return [Boolean] returns true if required, false if not
|
1896
1914
|
# @todo Add exception logic for systems with AIA healthcare ventilation requirements dual duct systems
|
1897
1915
|
def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
|
1898
1916
|
multizone_opt_required = false
|
@@ -1903,7 +1921,7 @@ class Standard
|
|
1903
1921
|
# in the Controller:MechanicalVentilation object to 'VentilationRateProcedure'
|
1904
1922
|
#
|
1905
1923
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1906
|
-
# @return [
|
1924
|
+
# @return [Boolean] returns true if required, false if not
|
1907
1925
|
def air_loop_hvac_enable_multizone_vav_optimization(air_loop_hvac)
|
1908
1926
|
# Enable multizone vav optimization
|
1909
1927
|
# at each timestep.
|
@@ -1928,7 +1946,7 @@ class Standard
|
|
1928
1946
|
# in the Controller:MechanicalVentilation object to 'ZoneSum'
|
1929
1947
|
#
|
1930
1948
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1931
|
-
# @return [
|
1949
|
+
# @return [Boolean] returns true if required, false if not
|
1932
1950
|
def air_loop_hvac_disable_multizone_vav_optimization(air_loop_hvac)
|
1933
1951
|
# Disable multizone vav optimization
|
1934
1952
|
# at each timestep.
|
@@ -1957,9 +1975,9 @@ class Standard
|
|
1957
1975
|
# Set the minimum VAV damper positions.
|
1958
1976
|
#
|
1959
1977
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1960
|
-
# @param has_ddc [
|
1978
|
+
# @param has_ddc [Boolean] if true, will assume that there is DDC control of vav terminals.
|
1961
1979
|
# If false, assumes otherwise.
|
1962
|
-
# @return [
|
1980
|
+
# @return [Boolean] returns true if successful, false if not
|
1963
1981
|
def air_loop_hvac_apply_minimum_vav_damper_positions(air_loop_hvac, has_ddc = true)
|
1964
1982
|
air_loop_hvac.thermalZones.each do |zone|
|
1965
1983
|
zone.equipment.each do |equip|
|
@@ -1978,7 +1996,7 @@ class Standard
|
|
1978
1996
|
# system outdoor air flow
|
1979
1997
|
#
|
1980
1998
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
1981
|
-
# @return [
|
1999
|
+
# @return [Boolean] returns true if required, false if not
|
1982
2000
|
# @todo Add exception logic for systems serving parking garage, warehouse, or multifamily
|
1983
2001
|
def air_loop_hvac_adjust_minimum_vav_damper_positions(air_loop_hvac)
|
1984
2002
|
# Do not apply the adjustment to some of the system in
|
@@ -2027,7 +2045,13 @@ class Standard
|
|
2027
2045
|
num_zones_adj = 0
|
2028
2046
|
|
2029
2047
|
# Retrieve the sum of the zone minimum primary airflow
|
2030
|
-
|
2048
|
+
if air_loop_hvac.model.version < OpenStudio::VersionString.new('3.6.0')
|
2049
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', 'Required AirLoopHVAC method .autosizedSumMinimumHeatingAirFlowRates is not available in pre-OpenStudio 3.6.0 versions. Use a more recent version of OpenStudio.')
|
2050
|
+
elsif air_loop_hvac.autosizedSumMinimumHeatingAirFlowRates.is_initialized
|
2051
|
+
vpz_min_sum = air_loop_hvac.autosizedSumMinimumHeatingAirFlowRates.get
|
2052
|
+
else
|
2053
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', "autosizedSumMinimumHeatingAirFlowRates is not available for air loop #{air_loop_hvac}.")
|
2054
|
+
end
|
2031
2055
|
|
2032
2056
|
air_loop_hvac.thermalZones.sort.each do |zone|
|
2033
2057
|
# Breathing zone airflow rate
|
@@ -2043,6 +2067,12 @@ class Standard
|
|
2043
2067
|
# max of heating and cooling
|
2044
2068
|
# design air flow rates
|
2045
2069
|
v_pz = 0.0
|
2070
|
+
|
2071
|
+
# error if zone autosized methods are not available
|
2072
|
+
if air_loop_hvac.model.version < OpenStudio::VersionString.new('3.6.0')
|
2073
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', 'Required ThermalZone method .autosizedCoolingDesignAirFlowRate and .autosizedHeatingDesignAirFlowRate are not available in pre-OpenStudio 3.6.0 versions. Use a more recent version of OpenStudio.')
|
2074
|
+
end
|
2075
|
+
|
2046
2076
|
clg_dsn_flow = zone.autosizedCoolingDesignAirFlowRate
|
2047
2077
|
if clg_dsn_flow.is_initialized
|
2048
2078
|
clg_dsn_flow = clg_dsn_flow.get
|
@@ -2174,7 +2204,17 @@ class Standard
|
|
2174
2204
|
# zone airflow are lower than the calculated system
|
2175
2205
|
# outdoor air intake
|
2176
2206
|
if v_ot_adj > vpz_min_sum && v_ot_adj > 0
|
2177
|
-
|
2207
|
+
|
2208
|
+
# Retrieve the sum of the zone maximum air flow rates
|
2209
|
+
if air_loop_hvac.model.version < OpenStudio::VersionString.new('3.6.0')
|
2210
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', 'Required AirLoopHVAC method .autosizedSumAirTerminalMaxAirFlowRate is not available in pre-OpenStudio 3.6.0 versions. Use a more recent version of OpenStudio.')
|
2211
|
+
elsif air_loop_hvac.autosizedSumAirTerminalMaxAirFlowRate.is_initialized
|
2212
|
+
v_max = air_loop_hvac.autosizedSumAirTerminalMaxAirFlowRate.get
|
2213
|
+
else
|
2214
|
+
OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.AirLoopHVAC', "autosizedSumAirTerminalMaxAirFlowRate is not available for air loop #{air_loop_hvac}.")
|
2215
|
+
end
|
2216
|
+
|
2217
|
+
mdp_adj = [v_ot_adj / v_max, 1].min
|
2178
2218
|
air_loop_hvac.thermalZones.sort.each do |zone|
|
2179
2219
|
air_loop_hvac_set_minimum_damper_position(zone, mdp_adj)
|
2180
2220
|
end
|
@@ -2200,7 +2240,7 @@ class Standard
|
|
2200
2240
|
#
|
2201
2241
|
# @param zone [OpenStudio::Model::ThermalZone] thermal zone
|
2202
2242
|
# @param mdp [Double] minimum damper position
|
2203
|
-
# @return [
|
2243
|
+
# @return [Boolean] returns true if successful, false if not
|
2204
2244
|
def air_loop_hvac_set_minimum_damper_position(zone, mdp)
|
2205
2245
|
zone.equipment.each do |equip|
|
2206
2246
|
if equip.to_AirTerminalSingleDuctVAVHeatAndCoolNoReheat.is_initialized
|
@@ -2229,7 +2269,7 @@ class Standard
|
|
2229
2269
|
# the results of the current climate zone
|
2230
2270
|
#
|
2231
2271
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2232
|
-
# @return [
|
2272
|
+
# @return [Boolean] returns true if successful, false if not
|
2233
2273
|
def air_loop_hvac_adjust_minimum_vav_damper_positions_outpatient(air_loop_hvac)
|
2234
2274
|
air_loop_hvac.model.getSpaces.sort.each do |space|
|
2235
2275
|
zone = space.thermalZone.get
|
@@ -2267,7 +2307,7 @@ class Standard
|
|
2267
2307
|
#
|
2268
2308
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2269
2309
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
2270
|
-
# @return [
|
2310
|
+
# @return [Boolean] returns true if required, false if not
|
2271
2311
|
# @todo Add exception logic for systems that serve multifamily, parking garage, warehouse
|
2272
2312
|
def air_loop_hvac_demand_control_ventilation_required?(air_loop_hvac, climate_zone)
|
2273
2313
|
dcv_required = false
|
@@ -2362,7 +2402,7 @@ class Standard
|
|
2362
2402
|
# when an energy recovery device is present. Defaults to true.
|
2363
2403
|
#
|
2364
2404
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2365
|
-
# @return [
|
2405
|
+
# @return [Boolean] returns true if required, false if not
|
2366
2406
|
def air_loop_hvac_dcv_required_when_erv(air_loop_hvac)
|
2367
2407
|
dcv_required_when_erv_present = false
|
2368
2408
|
return dcv_required_when_erv_present
|
@@ -2374,7 +2414,7 @@ class Standard
|
|
2374
2414
|
#
|
2375
2415
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2376
2416
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
2377
|
-
# @return [
|
2417
|
+
# @return [Boolean] returns true if required, false if not
|
2378
2418
|
def air_loop_hvac_enable_demand_control_ventilation(air_loop_hvac, climate_zone)
|
2379
2419
|
# Get the OA intake
|
2380
2420
|
controller_oa = nil
|
@@ -2407,7 +2447,7 @@ class Standard
|
|
2407
2447
|
#
|
2408
2448
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2409
2449
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
2410
|
-
# @return [
|
2450
|
+
# @return [Boolean] returns true if required, false if not
|
2411
2451
|
def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
|
2412
2452
|
is_sat_reset_required = false
|
2413
2453
|
return is_sat_reset_required
|
@@ -2416,7 +2456,7 @@ class Standard
|
|
2416
2456
|
# Enable supply air temperature (SAT) reset based on the cooling demand of the warmest zone.
|
2417
2457
|
#
|
2418
2458
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2419
|
-
# @return [
|
2459
|
+
# @return [Boolean] returns true if successful, false if not
|
2420
2460
|
def air_loop_hvac_enable_supply_air_temperature_reset_warmest_zone(air_loop_hvac)
|
2421
2461
|
# Get the current setpoint and calculate
|
2422
2462
|
# the new setpoint.
|
@@ -2463,7 +2503,7 @@ class Standard
|
|
2463
2503
|
# and reset linearly when outdoor air is between 50F and 70F.
|
2464
2504
|
#
|
2465
2505
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2466
|
-
# @return [
|
2506
|
+
# @return [Boolean] returns true if successful, false if not
|
2467
2507
|
def air_loop_hvac_enable_supply_air_temperature_reset_outdoor_temperature(air_loop_hvac)
|
2468
2508
|
# for AHU1 in Outpatient, SAT is 52F constant, no reset
|
2469
2509
|
return true if air_loop_hvac.name.get == 'PVAV Outpatient F1'
|
@@ -2506,7 +2546,7 @@ class Standard
|
|
2506
2546
|
# Determine if the system has an economizer
|
2507
2547
|
#
|
2508
2548
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2509
|
-
# @return [
|
2549
|
+
# @return [Boolean] returns true if required, false if not
|
2510
2550
|
def air_loop_hvac_economizer?(air_loop_hvac)
|
2511
2551
|
# Get the OA system and OA controller
|
2512
2552
|
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
@@ -2525,7 +2565,7 @@ class Standard
|
|
2525
2565
|
# Determine if the system is a VAV system based on the fan which may be inside of a unitary system.
|
2526
2566
|
#
|
2527
2567
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2528
|
-
# @return [
|
2568
|
+
# @return [Boolean] returns true if vav system, false if not
|
2529
2569
|
def air_loop_hvac_vav_system?(air_loop_hvac)
|
2530
2570
|
is_vav = false
|
2531
2571
|
air_loop_hvac.supplyComponents.reverse.each do |comp|
|
@@ -2552,7 +2592,7 @@ class Standard
|
|
2552
2592
|
# Determine if the system is a multizone VAV system
|
2553
2593
|
#
|
2554
2594
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2555
|
-
# @return [
|
2595
|
+
# @return [Boolean] returns true if multizone vav, false if not
|
2556
2596
|
def air_loop_hvac_multizone_vav_system?(air_loop_hvac)
|
2557
2597
|
multizone_vav_system = false
|
2558
2598
|
|
@@ -2576,7 +2616,7 @@ class Standard
|
|
2576
2616
|
# Determine if the system has terminal reheat
|
2577
2617
|
#
|
2578
2618
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2579
|
-
# @return [
|
2619
|
+
# @return [Boolean] returns true if has one or more reheat terminals, false if it doesn't
|
2580
2620
|
def air_loop_hvac_terminal_reheat?(air_loop_hvac)
|
2581
2621
|
has_term_rht = false
|
2582
2622
|
air_loop_hvac.demandComponents.each do |sc|
|
@@ -2596,7 +2636,7 @@ class Standard
|
|
2596
2636
|
# Determine if the system has energy recovery already
|
2597
2637
|
#
|
2598
2638
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2599
|
-
# @return [
|
2639
|
+
# @return [Boolean] returns true if an ERV is present, false if not
|
2600
2640
|
def air_loop_hvac_energy_recovery?(air_loop_hvac)
|
2601
2641
|
has_erv = false
|
2602
2642
|
|
@@ -2618,7 +2658,7 @@ class Standard
|
|
2618
2658
|
# Determine if the air loop is a unitary system
|
2619
2659
|
#
|
2620
2660
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2621
|
-
# @return [
|
2661
|
+
# @return [Boolean] returns true if a unitary system is present, false if not
|
2622
2662
|
def air_loop_hvac_unitary_system?(air_loop_hvac)
|
2623
2663
|
is_unitary_system = false
|
2624
2664
|
air_loop_hvac.supplyComponents.each do |component|
|
@@ -2634,7 +2674,7 @@ class Standard
|
|
2634
2674
|
# Set the VAV damper control to single maximum or dual maximum control depending on the standard.
|
2635
2675
|
#
|
2636
2676
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2637
|
-
# @return [
|
2677
|
+
# @return [Boolean] returns true if successful, false if not
|
2638
2678
|
# @todo see if this impacts the sizing run.
|
2639
2679
|
def air_loop_hvac_apply_vav_damper_action(air_loop_hvac)
|
2640
2680
|
damper_action = air_loop_hvac_vav_damper_action(air_loop_hvac)
|
@@ -2664,11 +2704,11 @@ class Standard
|
|
2664
2704
|
if term.reheatCoil.to_CoilHeatingWater.is_initialized
|
2665
2705
|
term.setDamperHeatingAction(damper_action_eplus)
|
2666
2706
|
control_type_set = true
|
2707
|
+
term.setMaximumFlowFractionDuringReheat(0.5)
|
2667
2708
|
end
|
2668
2709
|
else
|
2669
2710
|
term.setDamperHeatingAction(damper_action_eplus)
|
2670
2711
|
control_type_set = true
|
2671
|
-
term.setMaximumFlowFractionDuringReheat(0.5)
|
2672
2712
|
end
|
2673
2713
|
end
|
2674
2714
|
end
|
@@ -2694,7 +2734,7 @@ class Standard
|
|
2694
2734
|
#
|
2695
2735
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2696
2736
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
2697
|
-
# @return [
|
2737
|
+
# @return [Boolean] returns true if required, false if not
|
2698
2738
|
def air_loop_hvac_motorized_oa_damper_required?(air_loop_hvac, climate_zone)
|
2699
2739
|
motorized_oa_damper_required = false
|
2700
2740
|
|
@@ -2789,7 +2829,7 @@ class Standard
|
|
2789
2829
|
# @param min_occ_pct [Double] the fractional value below which the system will be considered unoccupied.
|
2790
2830
|
# @param occ_sch [OpenStudio::Model::Schedule] the occupancy schedule.
|
2791
2831
|
# If not supplied, one will be created based on the supplied occupancy threshold.
|
2792
|
-
# @return [
|
2832
|
+
# @return [Boolean] returns true if successful, false if not
|
2793
2833
|
def air_loop_hvac_add_motorized_oa_damper(air_loop_hvac, min_occ_pct = 0.05, occ_sch = nil)
|
2794
2834
|
# Get the OA system and OA controller
|
2795
2835
|
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
@@ -2832,7 +2872,7 @@ class Standard
|
|
2832
2872
|
# increases building loads unnecessarily during unoccupied hours.
|
2833
2873
|
#
|
2834
2874
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2835
|
-
# @return [
|
2875
|
+
# @return [Boolean] returns true if successful, false if not
|
2836
2876
|
def air_loop_hvac_remove_motorized_oa_damper(air_loop_hvac)
|
2837
2877
|
# Get the OA system and OA controller
|
2838
2878
|
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
@@ -2870,7 +2910,7 @@ class Standard
|
|
2870
2910
|
#
|
2871
2911
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
2872
2912
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
2873
|
-
# @return [
|
2913
|
+
# @return [Boolean] returns true if successful, false if not
|
2874
2914
|
def air_loop_hvac_apply_single_zone_controls(air_loop_hvac, climate_zone)
|
2875
2915
|
# These controls only apply to systems with DX cooling
|
2876
2916
|
unless air_loop_hvac_dx_cooling?(air_loop_hvac)
|
@@ -3242,8 +3282,8 @@ class Standard
|
|
3242
3282
|
# be added to the OpenStudio data model.
|
3243
3283
|
#
|
3244
3284
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
3245
|
-
# @param has_ddc [
|
3246
|
-
# return [
|
3285
|
+
# @param has_ddc [Boolean] whether or not the system has DDC control over VAV terminals.
|
3286
|
+
# return [Boolean] returns true if static pressure reset is required, false if not
|
3247
3287
|
def air_loop_hvac_static_pressure_reset_required?(air_loop_hvac, has_ddc)
|
3248
3288
|
sp_reset_required = false
|
3249
3289
|
|
@@ -3261,7 +3301,7 @@ class Standard
|
|
3261
3301
|
# Per ASHRAE 90.1 section 6.4.3.3, HVAC systems are required to have off-hour controls
|
3262
3302
|
#
|
3263
3303
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
3264
|
-
# @return [
|
3304
|
+
# @return [Boolean] returns true if required, false if not
|
3265
3305
|
def air_loop_hvac_unoccupied_fan_shutoff_required?(air_loop_hvac)
|
3266
3306
|
shutoff_required = true
|
3267
3307
|
|
@@ -3305,7 +3345,7 @@ class Standard
|
|
3305
3345
|
#
|
3306
3346
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
3307
3347
|
# @param min_occ_pct [Double] the fractional value below which the system will be considered unoccupied.
|
3308
|
-
# @return [
|
3348
|
+
# @return [Boolean] returns true if successful, false if not
|
3309
3349
|
def air_loop_hvac_enable_unoccupied_fan_shutoff(air_loop_hvac, min_occ_pct = 0.05)
|
3310
3350
|
# Set the system to night cycle
|
3311
3351
|
# The fan of a parallel PIU terminal are set to only cycle during heating operation
|
@@ -3510,7 +3550,7 @@ class Standard
|
|
3510
3550
|
#
|
3511
3551
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
3512
3552
|
# @param max_reheat_c [Double] the maximum reheat temperature, in degrees Celsius
|
3513
|
-
# @return [
|
3553
|
+
# @return [Boolean] returns true if successful, false if not
|
3514
3554
|
def air_loop_hvac_apply_maximum_reheat_temperature(air_loop_hvac, max_reheat_c)
|
3515
3555
|
air_loop_hvac.demandComponents.each do |sc|
|
3516
3556
|
if sc.to_AirTerminalSingleDuctConstantVolumeReheat.is_initialized
|
@@ -3538,7 +3578,7 @@ class Standard
|
|
3538
3578
|
# Set the system sizing properties based on the zone sizing information
|
3539
3579
|
#
|
3540
3580
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
3541
|
-
# @return [
|
3581
|
+
# @return [Boolean] returns true if successful, false if not
|
3542
3582
|
def air_loop_hvac_apply_prm_sizing_temperatures(air_loop_hvac)
|
3543
3583
|
# Get the design heating and cooling SAT information
|
3544
3584
|
# for all zones served by the system.
|
@@ -3610,7 +3650,7 @@ class Standard
|
|
3610
3650
|
# Determine if this Air Loop uses DX cooling.
|
3611
3651
|
#
|
3612
3652
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
3613
|
-
# @return [
|
3653
|
+
# @return [Boolean] returns true if uses DX cooling, false if not
|
3614
3654
|
def air_loop_hvac_dx_cooling?(air_loop_hvac)
|
3615
3655
|
dx_clg = false
|
3616
3656
|
|
@@ -3658,7 +3698,7 @@ class Standard
|
|
3658
3698
|
# Determine if this Air Loop uses multi-stage DX cooling.
|
3659
3699
|
#
|
3660
3700
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
3661
|
-
# @return [
|
3701
|
+
# @return [Boolean] returns true if uses multi-stage DX cooling, false if not
|
3662
3702
|
def air_loop_hvac_multi_stage_dx_cooling?(air_loop_hvac)
|
3663
3703
|
dx_clg = false
|
3664
3704
|
|
@@ -3701,8 +3741,8 @@ class Standard
|
|
3701
3741
|
|
3702
3742
|
# Get return fan power for airloop
|
3703
3743
|
#
|
3704
|
-
# @param
|
3705
|
-
# @return [
|
3744
|
+
# @param air_loop [OpenStudio::Model::AirLoopHVAC] AirLoopHVAC object
|
3745
|
+
# @return [Double] Fan power
|
3706
3746
|
def air_loop_hvac_get_return_fan_power(air_loop)
|
3707
3747
|
return_fan_power = 0
|
3708
3748
|
|
@@ -3728,8 +3768,8 @@ class Standard
|
|
3728
3768
|
|
3729
3769
|
# Get supply fan power for airloop
|
3730
3770
|
#
|
3731
|
-
# @param
|
3732
|
-
# @return [
|
3771
|
+
# @param air_loop [OpenStudio::Model::AirLoopHVAC] AirLoopHVAC object
|
3772
|
+
# @return [Double] Fan power
|
3733
3773
|
def air_loop_hvac_get_supply_fan_power(air_loop)
|
3734
3774
|
supply_fan_power = 0
|
3735
3775
|
|
@@ -3746,7 +3786,7 @@ class Standard
|
|
3746
3786
|
|
3747
3787
|
# Get supply fan for airloop
|
3748
3788
|
#
|
3749
|
-
# @param
|
3789
|
+
# @param air_loop [OpenStudio::Model::AirLoopHVAC] AirLoopHVAC object
|
3750
3790
|
# @return fan
|
3751
3791
|
def air_loop_hvac_get_supply_fan(air_loop)
|
3752
3792
|
fan = nil
|
@@ -3786,8 +3826,8 @@ class Standard
|
|
3786
3826
|
|
3787
3827
|
# Get relief fan power for airloop
|
3788
3828
|
#
|
3789
|
-
# @param
|
3790
|
-
# @return [
|
3829
|
+
# @param air_loop [OpenStudio::Model::AirLoopHVAC] AirLoopHVAC object
|
3830
|
+
# @return [Double] Fan power
|
3791
3831
|
def air_loop_hvac_get_relief_fan_power(air_loop)
|
3792
3832
|
relief_fan_power = 0
|
3793
3833
|
|
@@ -3817,8 +3857,8 @@ class Standard
|
|
3817
3857
|
# by scheduling air terminal dampers (so load can
|
3818
3858
|
# still be met) and cycling unitary system fans
|
3819
3859
|
#
|
3820
|
-
# @param air_loop_hvac [OpenStudio::
|
3821
|
-
# @param
|
3860
|
+
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] OpenStudio AirLoopHVAC object
|
3861
|
+
# @param standby_mode_spaces [Array<OpenStudio::Model::Space>] List of all spaces required to have standby mode controls
|
3822
3862
|
# @return [Boolean] true if sucessful, false otherwise
|
3823
3863
|
def air_loop_hvac_standby_mode_occupancy_control(air_loop_hvac, standby_mode_spaces)
|
3824
3864
|
return true
|
@@ -3830,7 +3870,6 @@ class Standard
|
|
3830
3870
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] HVAC air loop object
|
3831
3871
|
# @param oa_control [OpenStudio::Model::ControllerOutdoorAir] Outdoor air controller object to have this maximum OA fraction schedule
|
3832
3872
|
# @param snc [String] System name
|
3833
|
-
#
|
3834
3873
|
# @return [OpenStudio::Model::ScheduleRuleset] Generated maximum outdoor air fraction schedule for later use
|
3835
3874
|
def set_maximum_fraction_outdoor_air_schedule(air_loop_hvac, oa_control, snc)
|
3836
3875
|
max_oa_sch_name = "#{snc}maxOASch"
|
@@ -3839,7 +3878,7 @@ class Standard
|
|
3839
3878
|
max_oa_sch.defaultDaySchedule.setName("#{max_oa_sch_name}Default")
|
3840
3879
|
max_oa_sch.defaultDaySchedule.addValue(OpenStudio::Time.new(0, 24, 0, 0), 0.7)
|
3841
3880
|
oa_control.setMaximumFractionofOutdoorAirSchedule(max_oa_sch)
|
3842
|
-
max_oa_sch
|
3881
|
+
return max_oa_sch
|
3843
3882
|
end
|
3844
3883
|
|
3845
3884
|
# Checks if zones served by the air loop use zone exhaust fan
|