openstudio-standards 0.4.0 → 0.5.0.rc1
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/inventory/thermal_bridging.csv +90 -0
- data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
- data/lib/openstudio-standards/btap/analysis.rb +8 -8
- data/lib/openstudio-standards/btap/bridging.rb +664 -645
- data/lib/openstudio-standards/btap/btap.model.rb +14 -14
- data/lib/openstudio-standards/btap/btap.rb +7 -7
- data/lib/openstudio-standards/btap/btap_result.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +23 -23
- data/lib/openstudio-standards/btap/envelope.rb +8 -8
- data/lib/openstudio-standards/btap/equest.rb +1 -1
- data/lib/openstudio-standards/btap/geometry.rb +2 -2
- data/lib/openstudio-standards/btap/mpc.rb +7 -7
- data/lib/openstudio-standards/btap/schedules.rb +1 -1
- data/lib/openstudio-standards/btap/simmanager.rb +4 -4
- data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
- data/lib/openstudio-standards/btap/utilities.rb +6 -6
- data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
- data/lib/openstudio-standards/constructions/information.rb +83 -0
- data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
- data/lib/openstudio-standards/constructions/modify.rb +80 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
- data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
- data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
- data/lib/openstudio-standards/daylighting/space.rb +47 -0
- data/lib/openstudio-standards/geometry/create.rb +801 -0
- data/lib/openstudio-standards/geometry/create_bar.rb +2171 -0
- data/lib/openstudio-standards/geometry/information.rb +462 -0
- data/lib/openstudio-standards/geometry/modify.rb +48 -0
- data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
- data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
- data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
- data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
- data/lib/openstudio-standards/qaqc/eui.rb +213 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
- data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
- data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
- data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
- data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
- data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
- data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
- data/lib/openstudio-standards/schedules/create.rb +364 -0
- data/lib/openstudio-standards/schedules/information.rb +169 -0
- data/lib/openstudio-standards/schedules/modify.rb +445 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
- data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
- data/lib/openstudio-standards/utilities/assertion.rb +128 -0
- data/lib/openstudio-standards/utilities/logging.rb +2 -3
- data/lib/openstudio-standards/utilities/object_info.rb +39 -18
- data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
- data/lib/openstudio-standards/utilities/simulation.rb +24 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
- data/lib/openstudio-standards/weather/information.rb +35 -0
- data/lib/openstudio-standards.rb +69 -5
- metadata +52 -16
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
|
@@ -28,7 +28,7 @@
|
|
|
28
28
|
"template": "DOE Ref 1980-2004",
|
|
29
29
|
"climate_zone": "ASHRAE 169-2006-2B",
|
|
30
30
|
"data_center": false,
|
|
31
|
-
"capacity_limit":
|
|
31
|
+
"capacity_limit": 135000.0,
|
|
32
32
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
33
33
|
"notes": "Same as 90.1-2004"
|
|
34
34
|
},
|
|
@@ -84,7 +84,7 @@
|
|
|
84
84
|
"template": "DOE Ref 1980-2004",
|
|
85
85
|
"climate_zone": "ASHRAE 169-2006-5A",
|
|
86
86
|
"data_center": false,
|
|
87
|
-
"capacity_limit":
|
|
87
|
+
"capacity_limit": 135000.0,
|
|
88
88
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
89
89
|
"notes": "Same as 90.1-2004"
|
|
90
90
|
},
|
|
@@ -108,7 +108,7 @@
|
|
|
108
108
|
"template": "DOE Ref 1980-2004",
|
|
109
109
|
"climate_zone": "ASHRAE 169-2006-6A",
|
|
110
110
|
"data_center": false,
|
|
111
|
-
"capacity_limit":
|
|
111
|
+
"capacity_limit": 135000.0,
|
|
112
112
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
113
113
|
"notes": "Same as 90.1-2004"
|
|
114
114
|
},
|
|
@@ -124,7 +124,7 @@
|
|
|
124
124
|
"template": "DOE Ref 1980-2004",
|
|
125
125
|
"climate_zone": "ASHRAE 169-2006-7A",
|
|
126
126
|
"data_center": false,
|
|
127
|
-
"capacity_limit":
|
|
127
|
+
"capacity_limit": 135000.0,
|
|
128
128
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
129
129
|
"notes": "Same as 90.1-2004"
|
|
130
130
|
},
|
|
@@ -132,7 +132,7 @@
|
|
|
132
132
|
"template": "DOE Ref 1980-2004",
|
|
133
133
|
"climate_zone": "ASHRAE 169-2006-7B",
|
|
134
134
|
"data_center": false,
|
|
135
|
-
"capacity_limit":
|
|
135
|
+
"capacity_limit": 135000.0,
|
|
136
136
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
137
137
|
"notes": "Same as 90.1-2004"
|
|
138
138
|
},
|
|
@@ -140,7 +140,7 @@
|
|
|
140
140
|
"template": "DOE Ref 1980-2004",
|
|
141
141
|
"climate_zone": "ASHRAE 169-2006-8A",
|
|
142
142
|
"data_center": false,
|
|
143
|
-
"capacity_limit":
|
|
143
|
+
"capacity_limit": 135000.0,
|
|
144
144
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
145
145
|
"notes": "Same as 90.1-2004"
|
|
146
146
|
},
|
|
@@ -148,7 +148,7 @@
|
|
|
148
148
|
"template": "DOE Ref 1980-2004",
|
|
149
149
|
"climate_zone": "ASHRAE 169-2006-8B",
|
|
150
150
|
"data_center": false,
|
|
151
|
-
"capacity_limit":
|
|
151
|
+
"capacity_limit": 135000.0,
|
|
152
152
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
153
153
|
"notes": "Same as 90.1-2004"
|
|
154
154
|
},
|
|
@@ -180,7 +180,7 @@
|
|
|
180
180
|
"template": "DOE Ref 1980-2004",
|
|
181
181
|
"climate_zone": "ASHRAE 169-2013-2B",
|
|
182
182
|
"data_center": false,
|
|
183
|
-
"capacity_limit":
|
|
183
|
+
"capacity_limit": 135000.0,
|
|
184
184
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
185
185
|
"notes": "Same as 90.1-2004"
|
|
186
186
|
},
|
|
@@ -236,7 +236,7 @@
|
|
|
236
236
|
"template": "DOE Ref 1980-2004",
|
|
237
237
|
"climate_zone": "ASHRAE 169-2013-5A",
|
|
238
238
|
"data_center": false,
|
|
239
|
-
"capacity_limit":
|
|
239
|
+
"capacity_limit": 135000.0,
|
|
240
240
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
241
241
|
"notes": "Same as 90.1-2004"
|
|
242
242
|
},
|
|
@@ -260,7 +260,7 @@
|
|
|
260
260
|
"template": "DOE Ref 1980-2004",
|
|
261
261
|
"climate_zone": "ASHRAE 169-2013-6A",
|
|
262
262
|
"data_center": false,
|
|
263
|
-
"capacity_limit":
|
|
263
|
+
"capacity_limit": 135000.0,
|
|
264
264
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
265
265
|
"notes": "Same as 90.1-2004"
|
|
266
266
|
},
|
|
@@ -276,7 +276,7 @@
|
|
|
276
276
|
"template": "DOE Ref 1980-2004",
|
|
277
277
|
"climate_zone": "ASHRAE 169-2013-7A",
|
|
278
278
|
"data_center": false,
|
|
279
|
-
"capacity_limit":
|
|
279
|
+
"capacity_limit": 135000.0,
|
|
280
280
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
281
281
|
"notes": "Same as 90.1-2004"
|
|
282
282
|
},
|
|
@@ -284,7 +284,7 @@
|
|
|
284
284
|
"template": "DOE Ref 1980-2004",
|
|
285
285
|
"climate_zone": "ASHRAE 169-2013-7B",
|
|
286
286
|
"data_center": false,
|
|
287
|
-
"capacity_limit":
|
|
287
|
+
"capacity_limit": 135000.0,
|
|
288
288
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
289
289
|
"notes": "Same as 90.1-2004"
|
|
290
290
|
},
|
|
@@ -292,7 +292,7 @@
|
|
|
292
292
|
"template": "DOE Ref 1980-2004",
|
|
293
293
|
"climate_zone": "ASHRAE 169-2013-8A",
|
|
294
294
|
"data_center": false,
|
|
295
|
-
"capacity_limit":
|
|
295
|
+
"capacity_limit": 135000.0,
|
|
296
296
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
297
297
|
"notes": "Same as 90.1-2004"
|
|
298
298
|
},
|
|
@@ -300,7 +300,7 @@
|
|
|
300
300
|
"template": "DOE Ref 1980-2004",
|
|
301
301
|
"climate_zone": "ASHRAE 169-2013-8B",
|
|
302
302
|
"data_center": false,
|
|
303
|
-
"capacity_limit":
|
|
303
|
+
"capacity_limit": 135000.0,
|
|
304
304
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
305
305
|
"notes": "Same as 90.1-2004"
|
|
306
306
|
}
|
|
@@ -5,7 +5,7 @@ class DOERef1980to2004 < ASHRAE901
|
|
|
5
5
|
# Currently doesn't do anything for the DOE prototype buildings.
|
|
6
6
|
#
|
|
7
7
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
8
|
-
# return [
|
|
8
|
+
# return [Boolean] returns true if successful, false if not
|
|
9
9
|
# @todo enable damper position adjustment for legacy IDFS
|
|
10
10
|
def air_loop_hvac_apply_multizone_vav_outdoor_air_sizing(air_loop_hvac)
|
|
11
11
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', 'Damper positions not modified for DOE Ref Pre-1980 or DOE Ref 1980-2004 vintages.')
|
|
@@ -21,8 +21,8 @@ class DOERef1980to2004 < ASHRAE901
|
|
|
21
21
|
# be added to the OpenStudio data model.
|
|
22
22
|
#
|
|
23
23
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
24
|
-
# @param has_ddc [
|
|
25
|
-
# return [
|
|
24
|
+
# @param has_ddc [Boolean] whether or not the system has DDC control over VAV terminals.
|
|
25
|
+
# return [Boolean] returns true if static pressure reset is required, false if not
|
|
26
26
|
def air_loop_hvac_static_pressure_reset_required?(air_loop_hvac, has_ddc)
|
|
27
27
|
sp_reset_required = false
|
|
28
28
|
return sp_reset_required
|
|
@@ -32,7 +32,7 @@ class DOERef1980to2004 < ASHRAE901
|
|
|
32
32
|
# Not required by DOE Ref 1980-2004.
|
|
33
33
|
#
|
|
34
34
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
35
|
-
# @return [
|
|
35
|
+
# @return [Boolean] returns true if required, false if not
|
|
36
36
|
def air_loop_hvac_optimum_start_required?(air_loop_hvac)
|
|
37
37
|
opt_start_required = false
|
|
38
38
|
return opt_start_required
|
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb
CHANGED
|
@@ -7,7 +7,7 @@ class DOERef1980to2004 < ASHRAE901
|
|
|
7
7
|
# no changes are actually made to the model.
|
|
8
8
|
#
|
|
9
9
|
# base infiltration rates off of.
|
|
10
|
-
# @return [
|
|
10
|
+
# @return [Boolean] returns true if successful, false if not
|
|
11
11
|
# @todo This infiltration method is not used by the Reference
|
|
12
12
|
# buildings, fix this inconsistency.
|
|
13
13
|
def model_apply_infiltration_standard(model)
|
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb
CHANGED
|
@@ -5,7 +5,7 @@ class DOERef1980to2004 < ASHRAE901
|
|
|
5
5
|
# Not required for the older DOE buildings.
|
|
6
6
|
#
|
|
7
7
|
# @param plant_loop [OpenStudio::Model::PlantLoop] plant loop
|
|
8
|
-
# @return [
|
|
8
|
+
# @return [Boolean] returns true if required, false if not
|
|
9
9
|
def plant_loop_supply_water_temperature_reset_required?(plant_loop)
|
|
10
10
|
reset_required = false
|
|
11
11
|
return reset_required
|
|
@@ -28,7 +28,7 @@
|
|
|
28
28
|
"template": "DOE Ref Pre-1980",
|
|
29
29
|
"climate_zone": "ASHRAE 169-2006-2B",
|
|
30
30
|
"data_center": false,
|
|
31
|
-
"capacity_limit":
|
|
31
|
+
"capacity_limit": 135000.0,
|
|
32
32
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
33
33
|
"notes": "Same as 90.1-2004"
|
|
34
34
|
},
|
|
@@ -84,7 +84,7 @@
|
|
|
84
84
|
"template": "DOE Ref Pre-1980",
|
|
85
85
|
"climate_zone": "ASHRAE 169-2006-5A",
|
|
86
86
|
"data_center": false,
|
|
87
|
-
"capacity_limit":
|
|
87
|
+
"capacity_limit": 135000.0,
|
|
88
88
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
89
89
|
"notes": "Same as 90.1-2004"
|
|
90
90
|
},
|
|
@@ -108,7 +108,7 @@
|
|
|
108
108
|
"template": "DOE Ref Pre-1980",
|
|
109
109
|
"climate_zone": "ASHRAE 169-2006-6A",
|
|
110
110
|
"data_center": false,
|
|
111
|
-
"capacity_limit":
|
|
111
|
+
"capacity_limit": 135000.0,
|
|
112
112
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
113
113
|
"notes": "Same as 90.1-2004"
|
|
114
114
|
},
|
|
@@ -124,7 +124,7 @@
|
|
|
124
124
|
"template": "DOE Ref Pre-1980",
|
|
125
125
|
"climate_zone": "ASHRAE 169-2006-7A",
|
|
126
126
|
"data_center": false,
|
|
127
|
-
"capacity_limit":
|
|
127
|
+
"capacity_limit": 135000.0,
|
|
128
128
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
129
129
|
"notes": "Same as 90.1-2004"
|
|
130
130
|
},
|
|
@@ -132,7 +132,7 @@
|
|
|
132
132
|
"template": "DOE Ref Pre-1980",
|
|
133
133
|
"climate_zone": "ASHRAE 169-2006-7B",
|
|
134
134
|
"data_center": false,
|
|
135
|
-
"capacity_limit":
|
|
135
|
+
"capacity_limit": 135000.0,
|
|
136
136
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
137
137
|
"notes": "Same as 90.1-2004"
|
|
138
138
|
},
|
|
@@ -140,7 +140,7 @@
|
|
|
140
140
|
"template": "DOE Ref Pre-1980",
|
|
141
141
|
"climate_zone": "ASHRAE 169-2006-8A",
|
|
142
142
|
"data_center": false,
|
|
143
|
-
"capacity_limit":
|
|
143
|
+
"capacity_limit": 135000.0,
|
|
144
144
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
145
145
|
"notes": "Same as 90.1-2004"
|
|
146
146
|
},
|
|
@@ -148,7 +148,7 @@
|
|
|
148
148
|
"template": "DOE Ref Pre-1980",
|
|
149
149
|
"climate_zone": "ASHRAE 169-2006-8B",
|
|
150
150
|
"data_center": false,
|
|
151
|
-
"capacity_limit":
|
|
151
|
+
"capacity_limit": 135000.0,
|
|
152
152
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
153
153
|
"notes": "Same as 90.1-2004"
|
|
154
154
|
},
|
|
@@ -180,7 +180,7 @@
|
|
|
180
180
|
"template": "DOE Ref Pre-1980",
|
|
181
181
|
"climate_zone": "ASHRAE 169-2013-2B",
|
|
182
182
|
"data_center": false,
|
|
183
|
-
"capacity_limit":
|
|
183
|
+
"capacity_limit": 135000.0,
|
|
184
184
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
185
185
|
"notes": "Same as 90.1-2004"
|
|
186
186
|
},
|
|
@@ -236,7 +236,7 @@
|
|
|
236
236
|
"template": "DOE Ref Pre-1980",
|
|
237
237
|
"climate_zone": "ASHRAE 169-2013-5A",
|
|
238
238
|
"data_center": false,
|
|
239
|
-
"capacity_limit":
|
|
239
|
+
"capacity_limit": 135000.0,
|
|
240
240
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
241
241
|
"notes": "Same as 90.1-2004"
|
|
242
242
|
},
|
|
@@ -260,7 +260,7 @@
|
|
|
260
260
|
"template": "DOE Ref Pre-1980",
|
|
261
261
|
"climate_zone": "ASHRAE 169-2013-6A",
|
|
262
262
|
"data_center": false,
|
|
263
|
-
"capacity_limit":
|
|
263
|
+
"capacity_limit": 135000.0,
|
|
264
264
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
265
265
|
"notes": "Same as 90.1-2004"
|
|
266
266
|
},
|
|
@@ -276,7 +276,7 @@
|
|
|
276
276
|
"template": "DOE Ref Pre-1980",
|
|
277
277
|
"climate_zone": "ASHRAE 169-2013-7A",
|
|
278
278
|
"data_center": false,
|
|
279
|
-
"capacity_limit":
|
|
279
|
+
"capacity_limit": 135000.0,
|
|
280
280
|
"fixed_dry_bulb_high_limit_shutoff_temp": 70.0,
|
|
281
281
|
"notes": "Same as 90.1-2004"
|
|
282
282
|
},
|
|
@@ -284,7 +284,7 @@
|
|
|
284
284
|
"template": "DOE Ref Pre-1980",
|
|
285
285
|
"climate_zone": "ASHRAE 169-2013-7B",
|
|
286
286
|
"data_center": false,
|
|
287
|
-
"capacity_limit":
|
|
287
|
+
"capacity_limit": 135000.0,
|
|
288
288
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
289
289
|
"notes": "Same as 90.1-2004"
|
|
290
290
|
},
|
|
@@ -292,7 +292,7 @@
|
|
|
292
292
|
"template": "DOE Ref Pre-1980",
|
|
293
293
|
"climate_zone": "ASHRAE 169-2013-8A",
|
|
294
294
|
"data_center": false,
|
|
295
|
-
"capacity_limit":
|
|
295
|
+
"capacity_limit": 135000.0,
|
|
296
296
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
297
297
|
"notes": "Same as 90.1-2004"
|
|
298
298
|
},
|
|
@@ -300,7 +300,7 @@
|
|
|
300
300
|
"template": "DOE Ref Pre-1980",
|
|
301
301
|
"climate_zone": "ASHRAE 169-2013-8B",
|
|
302
302
|
"data_center": false,
|
|
303
|
-
"capacity_limit":
|
|
303
|
+
"capacity_limit": 135000.0,
|
|
304
304
|
"fixed_dry_bulb_high_limit_shutoff_temp": 75.0,
|
|
305
305
|
"notes": "Same as 90.1-2004"
|
|
306
306
|
}
|
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb
CHANGED
|
@@ -5,7 +5,7 @@ class DOERefPre1980 < ASHRAE901
|
|
|
5
5
|
# Currently doesn't do anything for the DOE prototype buildings.
|
|
6
6
|
#
|
|
7
7
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
8
|
-
# return [
|
|
8
|
+
# return [Boolean] returns true if successful, false if not
|
|
9
9
|
# @todo enable damper position adjustment for legacy IDFS
|
|
10
10
|
def air_loop_hvac_apply_multizone_vav_outdoor_air_sizing(air_loop_hvac)
|
|
11
11
|
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', 'Damper positions not modified for DOE Ref Pre-1980 or DOE Ref 1980-2004 vintages.')
|
|
@@ -21,8 +21,8 @@ class DOERefPre1980 < ASHRAE901
|
|
|
21
21
|
# be added to the OpenStudio data model.
|
|
22
22
|
#
|
|
23
23
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
24
|
-
# @param has_ddc [
|
|
25
|
-
# return [
|
|
24
|
+
# @param has_ddc [Boolean] whether or not the system has DDC control over VAV terminals.
|
|
25
|
+
# return [Boolean] returns true if static pressure reset is required, false if not
|
|
26
26
|
def air_loop_hvac_static_pressure_reset_required?(air_loop_hvac, has_ddc)
|
|
27
27
|
sp_reset_required = false
|
|
28
28
|
return sp_reset_required
|
|
@@ -32,7 +32,7 @@ class DOERefPre1980 < ASHRAE901
|
|
|
32
32
|
# Not required by DOE Pre-1980.
|
|
33
33
|
#
|
|
34
34
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
35
|
-
# @return [
|
|
35
|
+
# @return [Boolean] returns true if required, false if not
|
|
36
36
|
def air_loop_hvac_optimum_start_required?(air_loop_hvac)
|
|
37
37
|
opt_start_required = false
|
|
38
38
|
return opt_start_required
|
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
CHANGED
|
@@ -7,7 +7,7 @@ class DOERefPre1980 < ASHRAE901
|
|
|
7
7
|
# no changes are actually made to the model.
|
|
8
8
|
#
|
|
9
9
|
# base infiltration rates off of.
|
|
10
|
-
# @return [
|
|
10
|
+
# @return [Boolean] returns true if successful, false if not
|
|
11
11
|
# @todo This infiltration method is not used by the Reference
|
|
12
12
|
# buildings, fix this inconsistency.
|
|
13
13
|
def model_apply_infiltration_standard(model)
|
data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb
CHANGED
|
@@ -5,7 +5,7 @@ class DOERefPre1980 < ASHRAE901
|
|
|
5
5
|
# Not required for the older DOE buildings.
|
|
6
6
|
#
|
|
7
7
|
# @param plant_loop [OpenStudio::Model::PlantLoop] plant loop
|
|
8
|
-
# @return [
|
|
8
|
+
# @return [Boolean] returns true if required, false if not
|
|
9
9
|
def plant_loop_supply_water_temperature_reset_required?(plant_loop)
|
|
10
10
|
reset_required = false
|
|
11
11
|
return reset_required
|
|
@@ -82,7 +82,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
82
82
|
#
|
|
83
83
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
84
84
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
85
|
-
# @return [
|
|
85
|
+
# @return [Boolean] returns true if required, false if not
|
|
86
86
|
def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
|
|
87
87
|
return true
|
|
88
88
|
end
|
|
@@ -93,7 +93,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
93
93
|
#
|
|
94
94
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
95
95
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
96
|
-
# @return [
|
|
96
|
+
# @return [Boolean] Returns true if allowable, if the system has no economizer or no OA system.
|
|
97
97
|
# Returns false if the economizer type is not allowable.
|
|
98
98
|
def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
|
|
99
99
|
# EnergyPlus economizer types
|
|
@@ -181,7 +181,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
181
181
|
#
|
|
182
182
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
183
183
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
184
|
-
# @return [
|
|
184
|
+
# @return [Boolean] returns true if required, false if not
|
|
185
185
|
# @todo Add exception logic for systems with AIA healthcare ventilation requirements dual duct systems
|
|
186
186
|
def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
|
|
187
187
|
multizone_opt_required = false
|
|
@@ -278,7 +278,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
278
278
|
# DCV and an ERV may be used in conjunction.
|
|
279
279
|
#
|
|
280
280
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
281
|
-
# @return [
|
|
281
|
+
# @return [Boolean] returns true if required, false if not
|
|
282
282
|
def air_loop_hvac_dcv_required_when_erv(air_loop_hvac)
|
|
283
283
|
dcv_required_when_erv_present = true
|
|
284
284
|
return dcv_required_when_erv_present
|
|
@@ -347,7 +347,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
347
347
|
#
|
|
348
348
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
349
349
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
350
|
-
# @return [
|
|
350
|
+
# @return [Boolean] returns true if required, false if not
|
|
351
351
|
def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
|
|
352
352
|
is_sat_reset_required = false
|
|
353
353
|
|
|
@@ -418,7 +418,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
418
418
|
#
|
|
419
419
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
420
420
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
421
|
-
# @return [
|
|
421
|
+
# @return [Boolean] Returns true if required, false if not
|
|
422
422
|
def air_loop_hvac_energy_recovery_ventilator_required?(air_loop_hvac, climate_zone)
|
|
423
423
|
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
|
424
424
|
oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
|
|
@@ -5,7 +5,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
5
5
|
# For terminals with hot water heat and DDC, the minimum is 20%, otherwise the minimum is 30%.
|
|
6
6
|
#
|
|
7
7
|
# @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
|
|
8
|
-
# @param has_ddc [
|
|
8
|
+
# @param has_ddc [Boolean] whether or not there is DDC control of the VAV terminal in question
|
|
9
9
|
# @return [Double] minimum damper position
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_minimum_damper_position(air_terminal_single_duct_vav_reheat, has_ddc = true)
|
|
11
11
|
min_damper_position = nil
|
|
@@ -6,7 +6,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
6
6
|
# Apply the efficiency, plus Multicell heat rejection with VSD per 90.1-2013 6.5.2.2
|
|
7
7
|
#
|
|
8
8
|
# @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] variable speed cooling tower
|
|
9
|
-
# @return [
|
|
9
|
+
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
|
|
11
11
|
cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
|
|
12
12
|
cooling_tower_variable_speed.setCellControl('MaximalCell')
|
|
@@ -4,7 +4,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
4
4
|
# Applies the chilled water pumping controls to the loop based on Appendix G.
|
|
5
5
|
#
|
|
6
6
|
# @param plant_loop [OpenStudio::Model::PlantLoop] chilled water loop
|
|
7
|
-
# @return [
|
|
7
|
+
# @return [Boolean] returns true if successful, false if not
|
|
8
8
|
def plant_loop_apply_prm_baseline_chilled_water_pumping_type(plant_loop)
|
|
9
9
|
pri_control_type = 'VSD DP Reset'
|
|
10
10
|
sec_control_type = 'VSD DP Reset'
|
data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb
CHANGED
|
@@ -79,9 +79,9 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
79
79
|
# @param areas [Hash] a hash of daylighted areas
|
|
80
80
|
# @param sorted_windows [Hash] a hash of windows, sorted by priority
|
|
81
81
|
# @param sorted_skylights [Hash] a hash of skylights, sorted by priority
|
|
82
|
-
# @param req_top_ctrl [
|
|
83
|
-
# @param req_pri_ctrl [
|
|
84
|
-
# @param req_sec_ctrl [
|
|
82
|
+
# @param req_top_ctrl [Boolean] if toplighting controls are required
|
|
83
|
+
# @param req_pri_ctrl [Boolean] if primary sidelighting controls are required
|
|
84
|
+
# @param req_sec_ctrl [Boolean] if secondary sidelighting controls are required
|
|
85
85
|
# @return [Array] array of 4 items
|
|
86
86
|
# [sensor 1 fraction, sensor 2 fraction, sensor 1 window, sensor 2 window]
|
|
87
87
|
def space_daylighting_fractions_and_windows(space,
|
|
@@ -140,7 +140,7 @@ class NRELZNEReady2017 < ASHRAE901
|
|
|
140
140
|
# Baseline infiltration rate
|
|
141
141
|
#
|
|
142
142
|
# @return [Double] the baseline infiltration rate, in cfm/ft^2 exterior above grade wall area at 75 Pa
|
|
143
|
-
def space_infiltration_rate_75_pa(space)
|
|
143
|
+
def space_infiltration_rate_75_pa(space = nil)
|
|
144
144
|
basic_infil_rate_cfm_per_ft2 = 0.5 # Half of 90.1-2013
|
|
145
145
|
return basic_infil_rate_cfm_per_ft2
|
|
146
146
|
end
|
|
@@ -82,7 +82,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
82
82
|
#
|
|
83
83
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
84
84
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
85
|
-
# @return [
|
|
85
|
+
# @return [Boolean] returns true if required, false if not
|
|
86
86
|
def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
|
|
87
87
|
return true
|
|
88
88
|
end
|
|
@@ -93,7 +93,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
93
93
|
#
|
|
94
94
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
95
95
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
96
|
-
# @return [
|
|
96
|
+
# @return [Boolean] Returns true if allowable, if the system has no economizer or no OA system.
|
|
97
97
|
# Returns false if the economizer type is not allowable.
|
|
98
98
|
def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
|
|
99
99
|
# EnergyPlus economizer types
|
|
@@ -181,7 +181,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
181
181
|
#
|
|
182
182
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
183
183
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
184
|
-
# @return [
|
|
184
|
+
# @return [Boolean] returns true if required, false if not
|
|
185
185
|
# @todo Add exception logic for systems with AIA healthcare ventilation requirements dual duct systems
|
|
186
186
|
def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
|
|
187
187
|
multizone_opt_required = false
|
|
@@ -278,7 +278,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
278
278
|
# DCV and an ERV may be used in conjunction.
|
|
279
279
|
#
|
|
280
280
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
281
|
-
# @return [
|
|
281
|
+
# @return [Boolean] returns true if required, false if not
|
|
282
282
|
def air_loop_hvac_dcv_required_when_erv(air_loop_hvac)
|
|
283
283
|
dcv_required_when_erv_present = true
|
|
284
284
|
return dcv_required_when_erv_present
|
|
@@ -347,7 +347,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
347
347
|
#
|
|
348
348
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
349
349
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
350
|
-
# @return [
|
|
350
|
+
# @return [Boolean] returns true if required, false if not
|
|
351
351
|
def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
|
|
352
352
|
is_sat_reset_required = false
|
|
353
353
|
|
|
@@ -418,7 +418,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
418
418
|
#
|
|
419
419
|
# @param air_loop_hvac [OpenStudio::Model::AirLoopHVAC] air loop
|
|
420
420
|
# @param climate_zone [String] ASHRAE climate zone, e.g. 'ASHRAE 169-2013-4A'
|
|
421
|
-
# @return [
|
|
421
|
+
# @return [Boolean] Returns true if required, false if not
|
|
422
422
|
def air_loop_hvac_energy_recovery_ventilator_required?(air_loop_hvac, climate_zone)
|
|
423
423
|
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
|
424
424
|
oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
|
|
@@ -5,7 +5,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
5
5
|
# For terminals with hot water heat and DDC, the minimum is 20%, otherwise the minimum is 30%.
|
|
6
6
|
#
|
|
7
7
|
# @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
|
|
8
|
-
# @param has_ddc [
|
|
8
|
+
# @param has_ddc [Boolean] whether or not there is DDC control of the VAV terminal in question
|
|
9
9
|
# @return [Double] minimum damper position
|
|
10
10
|
def air_terminal_single_duct_vav_reheat_minimum_damper_position(air_terminal_single_duct_vav_reheat, has_ddc = true)
|
|
11
11
|
min_damper_position = nil
|
|
@@ -6,7 +6,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
6
6
|
# Apply the efficiency, plus Multicell heat rejection with VSD per 90.1-2013 6.5.2.2
|
|
7
7
|
#
|
|
8
8
|
# @param cooling_tower_variable_speed [OpenStudio::Model::CoolingTowerVariableSpeed] variable speed cooling tower
|
|
9
|
-
# @return [
|
|
9
|
+
# @return [Boolean] returns true if successful, false if not
|
|
10
10
|
def cooling_tower_variable_speed_apply_efficiency_and_curves(cooling_tower_variable_speed)
|
|
11
11
|
cooling_tower_apply_minimum_power_per_flow(cooling_tower_variable_speed)
|
|
12
12
|
cooling_tower_variable_speed.setCellControl('MaximalCell')
|
|
@@ -4,7 +4,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
4
4
|
# Applies the chilled water pumping controls to the loop based on Appendix G.
|
|
5
5
|
#
|
|
6
6
|
# @param plant_loop [OpenStudio::Model::PlantLoop] chilled water loop
|
|
7
|
-
# @return [
|
|
7
|
+
# @return [Boolean] returns true if successful, false if not
|
|
8
8
|
def plant_loop_apply_prm_baseline_chilled_water_pumping_type(plant_loop)
|
|
9
9
|
pri_control_type = 'VSD DP Reset'
|
|
10
10
|
sec_control_type = 'VSD DP Reset'
|
data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb
CHANGED
|
@@ -79,9 +79,9 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
79
79
|
# @param areas [Hash] a hash of daylighted areas
|
|
80
80
|
# @param sorted_windows [Hash] a hash of windows, sorted by priority
|
|
81
81
|
# @param sorted_skylights [Hash] a hash of skylights, sorted by priority
|
|
82
|
-
# @param req_top_ctrl [
|
|
83
|
-
# @param req_pri_ctrl [
|
|
84
|
-
# @param req_sec_ctrl [
|
|
82
|
+
# @param req_top_ctrl [Boolean] if toplighting controls are required
|
|
83
|
+
# @param req_pri_ctrl [Boolean] if primary sidelighting controls are required
|
|
84
|
+
# @param req_sec_ctrl [Boolean] if secondary sidelighting controls are required
|
|
85
85
|
# @return [Array] array of 4 items
|
|
86
86
|
# [sensor 1 fraction, sensor 2 fraction, sensor 1 window, sensor 2 window]
|
|
87
87
|
def space_daylighting_fractions_and_windows(space,
|
|
@@ -141,7 +141,7 @@ class ZEAEDGMultifamily < ASHRAE901
|
|
|
141
141
|
#
|
|
142
142
|
# @return [Double] the baseline infiltration rate, in cfm/ft^2
|
|
143
143
|
# defaults to no infiltration.
|
|
144
|
-
def space_infiltration_rate_75_pa(space)
|
|
144
|
+
def space_infiltration_rate_75_pa(space = nil)
|
|
145
145
|
basic_infil_rate_cfm_per_ft2 = 0.5 # Half of 90.1-2013
|
|
146
146
|
return basic_infil_rate_cfm_per_ft2
|
|
147
147
|
end
|