openstudio-standards 0.4.0 → 0.5.0.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/inventory/thermal_bridging.csv +90 -0
- data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
- data/lib/openstudio-standards/btap/analysis.rb +8 -8
- data/lib/openstudio-standards/btap/bridging.rb +664 -645
- data/lib/openstudio-standards/btap/btap.model.rb +14 -14
- data/lib/openstudio-standards/btap/btap.rb +7 -7
- data/lib/openstudio-standards/btap/btap_result.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +23 -23
- data/lib/openstudio-standards/btap/envelope.rb +8 -8
- data/lib/openstudio-standards/btap/equest.rb +1 -1
- data/lib/openstudio-standards/btap/geometry.rb +2 -2
- data/lib/openstudio-standards/btap/mpc.rb +7 -7
- data/lib/openstudio-standards/btap/schedules.rb +1 -1
- data/lib/openstudio-standards/btap/simmanager.rb +4 -4
- data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
- data/lib/openstudio-standards/btap/utilities.rb +6 -6
- data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
- data/lib/openstudio-standards/constructions/information.rb +83 -0
- data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
- data/lib/openstudio-standards/constructions/modify.rb +80 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
- data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
- data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
- data/lib/openstudio-standards/daylighting/space.rb +47 -0
- data/lib/openstudio-standards/geometry/create.rb +801 -0
- data/lib/openstudio-standards/geometry/create_bar.rb +2171 -0
- data/lib/openstudio-standards/geometry/information.rb +462 -0
- data/lib/openstudio-standards/geometry/modify.rb +48 -0
- data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
- data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
- data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
- data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
- data/lib/openstudio-standards/qaqc/eui.rb +213 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
- data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
- data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
- data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
- data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
- data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
- data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
- data/lib/openstudio-standards/schedules/create.rb +364 -0
- data/lib/openstudio-standards/schedules/information.rb +169 -0
- data/lib/openstudio-standards/schedules/modify.rb +445 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
- data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
- data/lib/openstudio-standards/utilities/assertion.rb +128 -0
- data/lib/openstudio-standards/utilities/logging.rb +2 -3
- data/lib/openstudio-standards/utilities/object_info.rb +39 -18
- data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
- data/lib/openstudio-standards/utilities/simulation.rb +24 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
- data/lib/openstudio-standards/weather/information.rb +35 -0
- data/lib/openstudio-standards.rb +69 -5
- metadata +52 -16
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -0,0 +1,141 @@
|
|
1
|
+
# Module to apply QAQC checks to a model
|
2
|
+
module OpenstudioStandards
|
3
|
+
module QAQC
|
4
|
+
# @!group QAQC HTML reporting
|
5
|
+
|
6
|
+
# Cleanup and prepare HTML
|
7
|
+
# measures calling this must add the following require calls:
|
8
|
+
# require 'json'
|
9
|
+
# require 'erb'
|
10
|
+
#
|
11
|
+
# @param html_in_path [String] HTML input path
|
12
|
+
# @param sections [Array] sections from create_sections_from_check_attributes
|
13
|
+
# @param name [String] the name that a user will see
|
14
|
+
# @return [String] HTML output path
|
15
|
+
def self.create_qaqc_html(html_in_path, sections, name)
|
16
|
+
# read in template
|
17
|
+
if File.exist?(html_in_path)
|
18
|
+
html_in_path = html_in_path
|
19
|
+
else
|
20
|
+
html_in_path = "#{File.dirname(__FILE__)}/report.html.erb"
|
21
|
+
end
|
22
|
+
html_in = ''
|
23
|
+
File.open(html_in_path, 'r') do |file|
|
24
|
+
html_in = file.read
|
25
|
+
end
|
26
|
+
|
27
|
+
# configure template with variable values
|
28
|
+
# instance variables for erb
|
29
|
+
@sections = sections
|
30
|
+
@name = name
|
31
|
+
renderer = ERB.new(html_in)
|
32
|
+
html_out = renderer.result(binding)
|
33
|
+
|
34
|
+
# write html file
|
35
|
+
html_out_path = './report.html'
|
36
|
+
File.open(html_out_path, 'w') do |file|
|
37
|
+
file << html_out
|
38
|
+
# make sure data is written to the disk one way or the other
|
39
|
+
begin
|
40
|
+
file.fsync
|
41
|
+
rescue StandardError
|
42
|
+
file.flush
|
43
|
+
end
|
44
|
+
end
|
45
|
+
|
46
|
+
return html_out_path
|
47
|
+
end
|
48
|
+
|
49
|
+
# Make HTML sections from a collection of QAQC checks
|
50
|
+
#
|
51
|
+
# @param check_elems [OpenStudio::AttributeVector.new] vector of check elements
|
52
|
+
# @return [Array] Array of HTML sections
|
53
|
+
def self.create_sections_from_check_attributes(check_elems)
|
54
|
+
# developer notes
|
55
|
+
# method below is custom version of standard OpenStudio results methods. It passes an array of sections vs. a single section.
|
56
|
+
# It doesn't use the model or SQL file. It just gets data form OpenStudio attributes passed in
|
57
|
+
# It doesn't have a name_only section since it doesn't populate user arguments
|
58
|
+
|
59
|
+
# inspecting check attributes
|
60
|
+
# make single table with checks.
|
61
|
+
# make second table with flag description (with column for where it came from)
|
62
|
+
|
63
|
+
# array to hold sections
|
64
|
+
sections = []
|
65
|
+
|
66
|
+
# gather data for section
|
67
|
+
qaqc_check_summary = {}
|
68
|
+
qaqc_check_summary[:title] = 'List of Checks in Measure'
|
69
|
+
qaqc_check_summary[:header] = ['Name', 'Category', 'Flags', 'Description']
|
70
|
+
qaqc_check_summary[:data] = []
|
71
|
+
qaqc_check_summary[:data_color] = []
|
72
|
+
@qaqc_check_section = {}
|
73
|
+
@qaqc_check_section[:title] = 'QAQC Check Summary'
|
74
|
+
@qaqc_check_section[:tables] = [qaqc_check_summary]
|
75
|
+
|
76
|
+
# add sections to array
|
77
|
+
sections << @qaqc_check_section
|
78
|
+
|
79
|
+
# counter for flags thrown
|
80
|
+
num_flags = 0
|
81
|
+
|
82
|
+
check_elems.each do |check|
|
83
|
+
# gather data for section
|
84
|
+
qaqc_flag_details = {}
|
85
|
+
qaqc_flag_details[:title] = "List of Flags Triggered for #{check.valueAsAttributeVector.first.valueAsString}."
|
86
|
+
qaqc_flag_details[:header] = ['Flag Detail']
|
87
|
+
qaqc_flag_details[:data] = []
|
88
|
+
@qaqc_flag_section = {}
|
89
|
+
@qaqc_flag_section[:title] = check.valueAsAttributeVector.first.valueAsString.to_s
|
90
|
+
@qaqc_flag_section[:tables] = [qaqc_flag_details]
|
91
|
+
|
92
|
+
check_name = nil
|
93
|
+
check_cat = nil
|
94
|
+
check_desc = nil
|
95
|
+
flags = []
|
96
|
+
# loop through attributes (name,category,description,then optionally one or more flag attributes)
|
97
|
+
check.valueAsAttributeVector.each_with_index do |value, index|
|
98
|
+
if index == 0
|
99
|
+
check_name = value.valueAsString
|
100
|
+
elsif index == 1
|
101
|
+
check_cat = value.valueAsString
|
102
|
+
elsif index == 2
|
103
|
+
check_desc = value.valueAsString
|
104
|
+
else # should be flag
|
105
|
+
flags << value.valueAsString
|
106
|
+
qaqc_flag_details[:data] << [value.valueAsString]
|
107
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.QAQC', "#{check_name} - #{value.valueAsString}")
|
108
|
+
num_flags += 1
|
109
|
+
end
|
110
|
+
end
|
111
|
+
|
112
|
+
# add row to table for this check
|
113
|
+
qaqc_check_summary[:data] << [check_name, check_cat, flags.size, check_desc]
|
114
|
+
|
115
|
+
# add info message for check if no flags found (this way user still knows what ran)
|
116
|
+
if check.valueAsAttributeVector.size < 4
|
117
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.QAQC', "#{check_name} - no flags.")
|
118
|
+
end
|
119
|
+
|
120
|
+
# color cells based and add logging messages based on flag status
|
121
|
+
if !flags.empty?
|
122
|
+
qaqc_check_summary[:data_color] << ['', '', 'indianred', '']
|
123
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.QAQC', "#{check_name.downcase.tr(' ', '_')} #{flags.size} flags")
|
124
|
+
else
|
125
|
+
qaqc_check_summary[:data_color] << ['', '', 'lightgreen', '']
|
126
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.QAQC', "#{check_name.downcase.tr(' ', '_')} #{flags.size} flags")
|
127
|
+
end
|
128
|
+
|
129
|
+
# add table for this check if there are flags
|
130
|
+
if !qaqc_flag_details[:data].empty?
|
131
|
+
sections << @qaqc_flag_section
|
132
|
+
end
|
133
|
+
end
|
134
|
+
|
135
|
+
# add total flags registerValue
|
136
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.QAQC', "total flags: #{num_flags}")
|
137
|
+
|
138
|
+
return sections
|
139
|
+
end
|
140
|
+
end
|
141
|
+
end
|
@@ -0,0 +1,129 @@
|
|
1
|
+
# Module to apply QAQC checks to a model
|
2
|
+
module OpenstudioStandards
|
3
|
+
module QAQC
|
4
|
+
# @!group Schedules
|
5
|
+
|
6
|
+
# Check that the lighting, equipment, and HVAC setpoint schedules coordinate with the occupancy schedules.
|
7
|
+
# This is defined as having start and end times within the specified number of hours away from the occupancy schedule.
|
8
|
+
#
|
9
|
+
# @param category [String] category to bin this check into
|
10
|
+
# @param target_standard [String] standard template, e.g. '90.1-2013'
|
11
|
+
# @param max_hrs [Double] threshold for throwing an error for schedule coordination
|
12
|
+
# @param name_only [Boolean] If true, only return the name of this check
|
13
|
+
# @return [OpenStudio::Attribute] OpenStudio Attribute object containing check results
|
14
|
+
def self.check_schedule_coordination(category, target_standard, max_hrs: 2.0, name_only: false)
|
15
|
+
# summary of the check
|
16
|
+
check_elems = OpenStudio::AttributeVector.new
|
17
|
+
check_elems << OpenStudio::Attribute.new('name', 'Schedule Coordination')
|
18
|
+
check_elems << OpenStudio::Attribute.new('category', category)
|
19
|
+
check_elems << OpenStudio::Attribute.new('description', 'Check that lighting, equipment, and HVAC schedules coordinate with occupancy.')
|
20
|
+
|
21
|
+
# stop here if only name is requested this is used to populate display name for arguments
|
22
|
+
if name_only == true
|
23
|
+
results = []
|
24
|
+
check_elems.each do |elem|
|
25
|
+
results << elem.valueAsString
|
26
|
+
end
|
27
|
+
return results
|
28
|
+
end
|
29
|
+
|
30
|
+
std = Standard.build(target_standard)
|
31
|
+
|
32
|
+
begin
|
33
|
+
# Convert max hr limit to OpenStudio Time
|
34
|
+
max_hrs = OpenStudio::Time.new(0, max_hrs.to_i, 0, 0)
|
35
|
+
|
36
|
+
# Check schedules in each space
|
37
|
+
@model.getSpaces.sort.each do |space|
|
38
|
+
# Occupancy, Lighting, and Equipment Schedules
|
39
|
+
coord_schs = []
|
40
|
+
occ_schs = []
|
41
|
+
# Get the space type (optional)
|
42
|
+
space_type = space.spaceType
|
43
|
+
|
44
|
+
# Occupancy
|
45
|
+
occs = []
|
46
|
+
occs += space.people # From space directly
|
47
|
+
occs += space_type.get.people if space_type.is_initialized # Inherited from space type
|
48
|
+
occs.each do |occ|
|
49
|
+
occ_schs << occ.numberofPeopleSchedule.get if occ.numberofPeopleSchedule.is_initialized
|
50
|
+
end
|
51
|
+
|
52
|
+
# Lights
|
53
|
+
lts = []
|
54
|
+
lts += space.lights # From space directly
|
55
|
+
lts += space_type.get.lights if space_type.is_initialized # Inherited from space type
|
56
|
+
lts.each do |lt|
|
57
|
+
coord_schs << lt.schedule.get if lt.schedule.is_initialized
|
58
|
+
end
|
59
|
+
|
60
|
+
# Equip
|
61
|
+
plugs = []
|
62
|
+
plugs += space.electricEquipment # From space directly
|
63
|
+
plugs += space_type.get.electricEquipment if space_type.is_initialized # Inherited from space type
|
64
|
+
plugs.each do |plug|
|
65
|
+
coord_schs << plug.schedule.get if plug.schedule.is_initialized
|
66
|
+
end
|
67
|
+
|
68
|
+
# HVAC Schedule (airloop-served zones only)
|
69
|
+
if space.thermalZone.is_initialized
|
70
|
+
zone = space.thermalZone.get
|
71
|
+
if zone.airLoopHVAC.is_initialized
|
72
|
+
coord_schs << zone.airLoopHVAC.get.availabilitySchedule
|
73
|
+
end
|
74
|
+
end
|
75
|
+
|
76
|
+
# Cannot check spaces with no occupancy schedule to compare against
|
77
|
+
next if occ_schs.empty?
|
78
|
+
|
79
|
+
# Get start and end occupancy times from the first occupancy schedule
|
80
|
+
times = OpenstudioStandards::Schedules.schedule_ruleset_get_start_and_end_times(occ_schs[0])
|
81
|
+
occ_start_time = times['start_time']
|
82
|
+
occ_end_time = times['end_time']
|
83
|
+
|
84
|
+
# Cannot check a space where the occupancy start time or end time cannot be determined
|
85
|
+
next if occ_start_time.nil? || occ_end_time.nil?
|
86
|
+
|
87
|
+
# Check all schedules against occupancy
|
88
|
+
|
89
|
+
# Lights should have a start and end within X hrs of the occupancy start and end
|
90
|
+
coord_schs.each do |coord_sch|
|
91
|
+
# Get start and end time of load/HVAC schedule
|
92
|
+
times = OpenstudioStandards::Schedules.schedule_ruleset_get_start_and_end_times(coord_sch)
|
93
|
+
start_time = times['start_time']
|
94
|
+
end_time = times['end_time]']
|
95
|
+
|
96
|
+
if start_time.nil?
|
97
|
+
check_elems << OpenStudio::Attribute.new('flag', "Could not determine start time of a schedule called #{coord_sch.name}, cannot determine if schedule coordinates with occupancy schedule.")
|
98
|
+
next
|
99
|
+
elsif end_time.nil?
|
100
|
+
check_elems << OpenStudio::Attribute.new('flag', "Could not determine end time of a schedule called #{coord_sch.name}, cannot determine if schedule coordinates with occupancy schedule.")
|
101
|
+
next
|
102
|
+
end
|
103
|
+
|
104
|
+
# Check start time
|
105
|
+
if (occ_start_time - start_time) > max_hrs || (start_time - occ_start_time) > max_hrs
|
106
|
+
check_elems << OpenStudio::Attribute.new('flag', "The start time of #{coord_sch.name} is #{start_time}, which is more than #{max_hrs} away from the occupancy schedule start time of #{occ_start_time} for #{occ_schs[0].name} in #{space.name}. Schedules do not coordinate.")
|
107
|
+
end
|
108
|
+
|
109
|
+
# Check end time
|
110
|
+
if (occ_end_time - end_time) > max_hrs || (end_time - occ_end_time) > max_hrs
|
111
|
+
check_elems << OpenStudio::Attribute.new('flag', "The end time of #{coord_sch.name} is #{end_time}, which is more than #{max_hrs} away from the occupancy schedule end time of #{occ_end_time} for #{occ_schs[0].name} in #{space.name}. Schedules do not coordinate.")
|
112
|
+
end
|
113
|
+
end
|
114
|
+
end
|
115
|
+
rescue StandardError => e
|
116
|
+
# brief description of ruby error
|
117
|
+
check_elems << OpenStudio::Attribute.new('flag', "Error prevented QAQC check from running (#{e}).")
|
118
|
+
|
119
|
+
# backtrace of ruby error for diagnostic use
|
120
|
+
if @error_backtrace then check_elems << OpenStudio::Attribute.new('flag', e.backtrace.join("\n").to_s) end
|
121
|
+
end
|
122
|
+
|
123
|
+
# add check_elms to new attribute
|
124
|
+
check_elem = OpenStudio::Attribute.new('check', check_elems)
|
125
|
+
|
126
|
+
return check_elem
|
127
|
+
end
|
128
|
+
end
|
129
|
+
end
|
@@ -0,0 +1,273 @@
|
|
1
|
+
# Module to apply QAQC checks to a model
|
2
|
+
module OpenstudioStandards
|
3
|
+
module QAQC
|
4
|
+
# @!group Service Water Heating
|
5
|
+
|
6
|
+
# Checks the hot water use in a model for typical values
|
7
|
+
#
|
8
|
+
# @param category [String] category to bin this check into
|
9
|
+
# @param target_standard [String] standard template, e.g. '90.1-2013'
|
10
|
+
# @param min_pass_pct [Double] threshold for throwing an error for percent difference
|
11
|
+
# @param max_pass_pct [Double] threshold for throwing an error for percent difference
|
12
|
+
# @param name_only [Boolean] If true, only return the name of this check
|
13
|
+
# @return [OpenStudio::Attribute] OpenStudio Attribute object containing check results
|
14
|
+
def self.check_service_hot_water(category, target_standard, min_pass_pct: 0.25, max_pass_pct: 0.25, name_only: false)
|
15
|
+
# @todo could expose meal turnover and people per unit for res and hotel into arguments
|
16
|
+
|
17
|
+
# summary of the check
|
18
|
+
check_elems = OpenStudio::AttributeVector.new
|
19
|
+
check_elems << OpenStudio::Attribute.new('name', 'Domestic Hot Water')
|
20
|
+
check_elems << OpenStudio::Attribute.new('category', category)
|
21
|
+
if target_standard == 'ICC IECC 2015'
|
22
|
+
check_elems << OpenStudio::Attribute.new('description', 'Check service water heating consumption against Table R405.5.2(1) in ICC IECC 2015 Residential Provisions.')
|
23
|
+
else
|
24
|
+
check_elems << OpenStudio::Attribute.new('description', 'Check against the 2011 ASHRAE Handbook - HVAC Applications, Table 7 section 50.14.')
|
25
|
+
end
|
26
|
+
|
27
|
+
# stop here if only name is requested this is used to populate display name for arguments
|
28
|
+
if name_only == true
|
29
|
+
results = []
|
30
|
+
check_elems.each do |elem|
|
31
|
+
results << elem.valueAsString
|
32
|
+
end
|
33
|
+
return results
|
34
|
+
end
|
35
|
+
|
36
|
+
std = Standard.build(target_standard)
|
37
|
+
|
38
|
+
begin
|
39
|
+
# loop through water_use_equipment
|
40
|
+
service_water_consumption_daily_avg_gal = 0.0
|
41
|
+
@model.getWaterUseEquipments.each do |water_use_equipment|
|
42
|
+
# get peak flow rate from def
|
43
|
+
peak_flow_rate_si = water_use_equipment.waterUseEquipmentDefinition.peakFlowRate
|
44
|
+
source_units = 'm^3/s'
|
45
|
+
target_units = 'gal/min'
|
46
|
+
peak_flow_rate_ip = OpenStudio.convert(peak_flow_rate_si, source_units, target_units).get
|
47
|
+
|
48
|
+
# get value from flow rate schedule
|
49
|
+
if water_use_equipment.flowRateFractionSchedule.is_initialized
|
50
|
+
# get annual equiv for model schedule
|
51
|
+
schedule_inst = water_use_equipment.flowRateFractionSchedule.get
|
52
|
+
if schedule_inst.to_ScheduleRuleset.is_initialized
|
53
|
+
annual_equiv_flow_rate = std.schedule_ruleset_annual_equivalent_full_load_hrs(schedule_inst.to_ScheduleRuleset.get)
|
54
|
+
elsif schedule_inst.to_ScheduleConstant.is_initialized
|
55
|
+
annual_equiv_flow_rate = std.schedule_constant_annual_equivalent_full_load_hrs(schedule_inst.to_ScheduleConstant.get)
|
56
|
+
else
|
57
|
+
check_elems << OpenStudio::Attribute.new('flag', "#{schedule_inst.name} isn't a Ruleset or Constant schedule. Can't calculate annual equivalent full load hours.")
|
58
|
+
next
|
59
|
+
end
|
60
|
+
else
|
61
|
+
# issue flag
|
62
|
+
check_elems << OpenStudio::Attribute.new('flag', "#{water_use_equipment.name} doesn't have a schedule. Can't identify hot water consumption.")
|
63
|
+
next
|
64
|
+
end
|
65
|
+
|
66
|
+
# add to global service water consumpiton value
|
67
|
+
service_water_consumption_daily_avg_gal += 60.0 * peak_flow_rate_ip * annual_equiv_flow_rate / 365.0
|
68
|
+
end
|
69
|
+
|
70
|
+
if target_standard == 'ICC IECC 2015'
|
71
|
+
|
72
|
+
num_people = 0.0
|
73
|
+
@model.getSpaceTypes.each do |space_type|
|
74
|
+
next if !space_type.standardsSpaceType.is_initialized
|
75
|
+
next if space_type.standardsSpaceType.get != 'Apartment' # currently only supports midrise apt space type
|
76
|
+
|
77
|
+
space_type_floor_area = space_type.floorArea
|
78
|
+
space_type_num_people = space_type.getNumberOfPeople(space_type_floor_area)
|
79
|
+
num_people += space_type_num_people
|
80
|
+
end
|
81
|
+
|
82
|
+
# lookup target gal/day for the building
|
83
|
+
bedrooms_per_unit = 2.0 # assumption
|
84
|
+
num_units = num_people / 2.5 # Avg 2.5 units per person.
|
85
|
+
target_consumption = std.model_find_icc_iecc_2015_hot_water_demand(@model, num_units, bedrooms_per_unit)
|
86
|
+
else
|
87
|
+
# only other path for now is 90.1-2013
|
88
|
+
|
89
|
+
# get building type
|
90
|
+
building_type = ''
|
91
|
+
if @model.getBuilding.standardsBuildingType.is_initialized
|
92
|
+
building_type = @model.getBuilding.standardsBuildingType.get
|
93
|
+
end
|
94
|
+
|
95
|
+
# lookup data from standards
|
96
|
+
ashrae_hot_water_demand = std.model_find_ashrae_hot_water_demand(@model)
|
97
|
+
|
98
|
+
# building type specific logic for water consumption
|
99
|
+
# todo - update test to exercise various building types
|
100
|
+
if !ashrae_hot_water_demand.empty?
|
101
|
+
|
102
|
+
if building_type == 'FullServiceRestaurant'
|
103
|
+
num_people_hours = 0.0
|
104
|
+
@model.getSpaceTypes.each do |space_type|
|
105
|
+
next if !space_type.standardsSpaceType.is_initialized
|
106
|
+
next if space_type.standardsSpaceType.get != 'Dining'
|
107
|
+
|
108
|
+
space_type_floor_area = space_type.floorArea
|
109
|
+
|
110
|
+
space_type_num_people_hours = 0.0
|
111
|
+
# loop through peole instances
|
112
|
+
space_type.peoples.each do |inst|
|
113
|
+
inst_num_people = inst.getNumberOfPeople(space_type_floor_area)
|
114
|
+
inst_schedule = inst.numberofPeopleSchedule.get # sim will fail prior to this if doesn't have it
|
115
|
+
|
116
|
+
if inst_schedule.to_ScheduleRuleset.is_initialized
|
117
|
+
annual_equiv_flow_rate = std.schedule_ruleset_annual_equivalent_full_load_hrs(inst_schedule.to_ScheduleRuleset.get)
|
118
|
+
elsif inst_schedule.to_ScheduleConstant.is_initialized
|
119
|
+
annual_equiv_flow_rate = std.schedule_constant_annual_equivalent_full_load_hrs(inst_schedule.to_ScheduleConstant.get)
|
120
|
+
else
|
121
|
+
check_elems << OpenStudio::Attribute.new('flag', "#{inst_schedule.name} isn't a Ruleset or Constant schedule. Can't calculate annual equivalent full load hours.")
|
122
|
+
annual_equiv_flow_rate = 0.0
|
123
|
+
end
|
124
|
+
|
125
|
+
inst_num_people_horus = annual_equiv_flow_rate * inst_num_people
|
126
|
+
space_type_num_people_hours += inst_num_people_horus
|
127
|
+
end
|
128
|
+
|
129
|
+
num_people_hours += space_type_num_people_hours
|
130
|
+
end
|
131
|
+
num_meals = num_people_hours / 365.0 * 1.5 # 90 minute meal
|
132
|
+
target_consumption = num_meals * ashrae_hot_water_demand.first[:avg_day_unit]
|
133
|
+
|
134
|
+
elsif ['LargeHotel', 'SmallHotel'].include? building_type
|
135
|
+
num_people = 0.0
|
136
|
+
@model.getSpaceTypes.each do |space_type|
|
137
|
+
next if !space_type.standardsSpaceType.is_initialized
|
138
|
+
next if space_type.standardsSpaceType.get != 'GuestRoom'
|
139
|
+
|
140
|
+
space_type_floor_area = space_type.floorArea
|
141
|
+
space_type_num_people = space_type.getNumberOfPeople(space_type_floor_area)
|
142
|
+
num_people += space_type_num_people
|
143
|
+
end
|
144
|
+
|
145
|
+
# find best fit from returned results
|
146
|
+
num_units = num_people / 2.0 # 2 people per room design load, not typical occupancy
|
147
|
+
avg_day_unit = nil
|
148
|
+
fit = nil
|
149
|
+
ashrae_hot_water_demand.each do |block|
|
150
|
+
if fit.nil?
|
151
|
+
avg_day_unit = block[:avg_day_unit]
|
152
|
+
fit = (avg_day_unit - block[:block]).abs
|
153
|
+
elsif (avg_day_unit - block[:block]).abs - fit
|
154
|
+
avg_day_unit = block[:avg_day_unit]
|
155
|
+
fit = (avg_day_unit - block[:block]).abs
|
156
|
+
end
|
157
|
+
end
|
158
|
+
target_consumption = num_units * avg_day_unit
|
159
|
+
|
160
|
+
elsif building_type == 'MidriseApartment'
|
161
|
+
num_people = 0.0
|
162
|
+
@model.getSpaceTypes.each do |space_type|
|
163
|
+
next if !space_type.standardsSpaceType.is_initialized
|
164
|
+
next if space_type.standardsSpaceType.get != 'Apartment'
|
165
|
+
|
166
|
+
space_type_floor_area = space_type.floorArea
|
167
|
+
space_type_num_people = space_type.getNumberOfPeople(space_type_floor_area)
|
168
|
+
num_people += space_type_num_people
|
169
|
+
end
|
170
|
+
|
171
|
+
# find best fit from returned results
|
172
|
+
num_units = num_people / 2.5 # Avg 2.5 units per person.
|
173
|
+
avg_day_unit = nil
|
174
|
+
fit = nil
|
175
|
+
ashrae_hot_water_demand.each do |block|
|
176
|
+
if fit.nil?
|
177
|
+
avg_day_unit = block[:avg_day_unit]
|
178
|
+
fit = (avg_day_unit - block[:block]).abs
|
179
|
+
elsif (avg_day_unit - block[:block]).abs - fit
|
180
|
+
avg_day_unit = block[:avg_day_unit]
|
181
|
+
fit = (avg_day_unit - block[:block]).abs
|
182
|
+
end
|
183
|
+
end
|
184
|
+
target_consumption = num_units * avg_day_unit
|
185
|
+
|
186
|
+
elsif ['Office', 'LargeOffice', 'MediumOffice', 'SmallOffice'].include? building_type
|
187
|
+
num_people = @model.getBuilding.numberOfPeople
|
188
|
+
target_consumption = num_people * ashrae_hot_water_demand.first[:avg_day_unit]
|
189
|
+
elsif building_type == 'PrimarySchool'
|
190
|
+
num_people = 0.0
|
191
|
+
@model.getSpaceTypes.each do |space_type|
|
192
|
+
next if !space_type.standardsSpaceType.is_initialized
|
193
|
+
next if space_type.standardsSpaceType.get != 'Classroom'
|
194
|
+
|
195
|
+
space_type_floor_area = space_type.floorArea
|
196
|
+
space_type_num_people = space_type.getNumberOfPeople(space_type_floor_area)
|
197
|
+
num_people += space_type_num_people
|
198
|
+
end
|
199
|
+
target_consumption = num_people * ashrae_hot_water_demand.first[:avg_day_unit]
|
200
|
+
elsif building_type == 'QuickServiceRestaurant'
|
201
|
+
num_people_hours = 0.0
|
202
|
+
@model.getSpaceTypes.each do |space_type|
|
203
|
+
next if !space_type.standardsSpaceType.is_initialized
|
204
|
+
next if space_type.standardsSpaceType.get != 'Dining'
|
205
|
+
|
206
|
+
space_type_floor_area = space_type.floorArea
|
207
|
+
|
208
|
+
space_type_num_people_hours = 0.0
|
209
|
+
# loop through peole instances
|
210
|
+
space_type.peoples.each do |inst|
|
211
|
+
inst_num_people = inst.getNumberOfPeople(space_type_floor_area)
|
212
|
+
inst_schedule = inst.numberofPeopleSchedule.get # sim will fail prior to this if doesn't have it
|
213
|
+
|
214
|
+
if inst_schedule.to_ScheduleRuleset.is_initialized
|
215
|
+
annual_equiv_flow_rate = std.schedule_ruleset_annual_equivalent_full_load_hrs(inst_schedule.to_ScheduleRuleset.get)
|
216
|
+
elsif inst_schedule.to_ScheduleConstant.is_initialized
|
217
|
+
annual_equiv_flow_rate = std.schedule_constant_annual_equivalent_full_load_hrs(inst_schedule.to_ScheduleConstant.get)
|
218
|
+
else
|
219
|
+
check_elems << OpenStudio::Attribute.new('flag', "#{inst_schedule.name} isn't a Ruleset or Constant schedule. Can't calculate annual equivalent full load hours.")
|
220
|
+
annual_equiv_flow_rate = 0.0
|
221
|
+
end
|
222
|
+
|
223
|
+
inst_num_people_horus = annual_equiv_flow_rate * inst_num_people
|
224
|
+
space_type_num_people_hours += inst_num_people_horus
|
225
|
+
end
|
226
|
+
|
227
|
+
num_people_hours += space_type_num_people_hours
|
228
|
+
end
|
229
|
+
num_meals = num_people_hours / 365.0 * 0.5 # 30 minute leal
|
230
|
+
# todo - add logic to address drive through traffic
|
231
|
+
target_consumption = num_meals * ashrae_hot_water_demand.first[:avg_day_unit]
|
232
|
+
|
233
|
+
elsif building_type == 'SecondarySchool'
|
234
|
+
num_people = 0.0
|
235
|
+
@model.getSpaceTypes.each do |space_type|
|
236
|
+
next if !space_type.standardsSpaceType.is_initialized
|
237
|
+
next if space_type.standardsSpaceType.get != 'Classroom'
|
238
|
+
|
239
|
+
space_type_floor_area = space_type.floorArea
|
240
|
+
space_type_num_people = space_type.getNumberOfPeople(space_type_floor_area)
|
241
|
+
num_people += space_type_num_people
|
242
|
+
end
|
243
|
+
target_consumption = num_people * ashrae_hot_water_demand.first[:avg_day_unit]
|
244
|
+
else
|
245
|
+
check_elems << OpenStudio::Attribute.new('flag', "No rule of thumb values exist for #{building_type}. Hot water consumption was not checked.")
|
246
|
+
end
|
247
|
+
|
248
|
+
else
|
249
|
+
check_elems << OpenStudio::Attribute.new('flag', "No rule of thumb values exist for #{building_type}. Hot water consumption was not checked.")
|
250
|
+
end
|
251
|
+
end
|
252
|
+
|
253
|
+
# check actual against target
|
254
|
+
if service_water_consumption_daily_avg_gal < target_consumption * (1.0 - min_pass_pct)
|
255
|
+
check_elems << OpenStudio::Attribute.new('flag', "Annual average of #{service_water_consumption_daily_avg_gal.round} gallons per day of hot water is more than #{min_pass_pct * 100} % below the expected value of #{target_consumption.round} gallons per day.")
|
256
|
+
elsif service_water_consumption_daily_avg_gal > target_consumption * (1.0 + max_pass_pct)
|
257
|
+
check_elems << OpenStudio::Attribute.new('flag', "Annual average of #{service_water_consumption_daily_avg_gal.round} gallons per day of hot water is more than #{max_pass_pct * 100} % above the expected value of #{target_consumption.round} gallons per day.")
|
258
|
+
end
|
259
|
+
rescue StandardError => e
|
260
|
+
# brief description of ruby error
|
261
|
+
check_elems << OpenStudio::Attribute.new('flag', "Error prevented QAQC check from running (#{e}).")
|
262
|
+
|
263
|
+
# backtrace of ruby error for diagnostic use
|
264
|
+
if @error_backtrace then check_elems << OpenStudio::Attribute.new('flag', e.backtrace.join("\n").to_s) end
|
265
|
+
end
|
266
|
+
|
267
|
+
# add check_elms to new attribute
|
268
|
+
check_elem = OpenStudio::Attribute.new('check', check_elems)
|
269
|
+
|
270
|
+
return check_elem
|
271
|
+
end
|
272
|
+
end
|
273
|
+
end
|