openstudio-standards 0.4.0 → 0.5.0.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/data/inventory/thermal_bridging.csv +90 -0
- data/data/standards/OpenStudio_Standards-deer-comstock.xlsx +0 -0
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/test_performance_expected_dd_results.csv +2014 -1891
- data/lib/openstudio-standards/btap/analysis.rb +8 -8
- data/lib/openstudio-standards/btap/bridging.rb +664 -645
- data/lib/openstudio-standards/btap/btap.model.rb +14 -14
- data/lib/openstudio-standards/btap/btap.rb +7 -7
- data/lib/openstudio-standards/btap/btap_result.rb +1 -1
- data/lib/openstudio-standards/btap/economics.rb +23 -23
- data/lib/openstudio-standards/btap/envelope.rb +8 -8
- data/lib/openstudio-standards/btap/equest.rb +1 -1
- data/lib/openstudio-standards/btap/geometry.rb +2 -2
- data/lib/openstudio-standards/btap/mpc.rb +7 -7
- data/lib/openstudio-standards/btap/schedules.rb +1 -1
- data/lib/openstudio-standards/btap/simmanager.rb +4 -4
- data/lib/openstudio-standards/btap/spaceloads.rb +26 -26
- data/lib/openstudio-standards/btap/utilities.rb +6 -6
- data/lib/openstudio-standards/btap/vintagizer.rb +1 -1
- data/lib/openstudio-standards/constructions/information.rb +83 -0
- data/lib/openstudio-standards/constructions/materials/modify.rb +72 -0
- data/lib/openstudio-standards/constructions/modify.rb +80 -0
- data/lib/openstudio-standards/create_typical/create_typical.rb +983 -0
- data/lib/openstudio-standards/create_typical/enumerations.rb +484 -0
- data/lib/openstudio-standards/create_typical/space_type_blend.rb +791 -0
- data/lib/openstudio-standards/create_typical/space_type_ratios.rb +494 -0
- data/lib/openstudio-standards/daylighting/space.rb +47 -0
- data/lib/openstudio-standards/geometry/create.rb +801 -0
- data/lib/openstudio-standards/geometry/create_bar.rb +2171 -0
- data/lib/openstudio-standards/geometry/information.rb +462 -0
- data/lib/openstudio-standards/geometry/modify.rb +48 -0
- data/lib/openstudio-standards/hvac/air_loop/information.rb +79 -0
- data/lib/openstudio-standards/hvac/cbecs_hvac.rb +616 -0
- data/lib/openstudio-standards/hvac/setpoint_managers/information.rb +91 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.rb +4 -36
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +3 -3
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.elevators.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.College.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Courthouse.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.FullServiceRestaurant.rb +14 -14
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.HighRiseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +16 -16
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Laboratory.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +7 -7
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MidriseApartment.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.QuickServiceRestaurant.rb +13 -13
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStripmall.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -9
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterHighITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallDataCenterLowITE.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallHotel.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOffice.rb +8 -8
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SmallOfficeDetailed.rb +11 -11
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperMarket.rb +10 -10
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SuperTallBuilding.rb +19 -19
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.TallBuilding.rb +18 -18
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Warehouse.rb +6 -6
- data/lib/openstudio-standards/prototypes/common/do_not_edit_metaclasses.rb +957 -957
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirConditionerVariableRefrigerantFlow.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingWaterToAirHeatPumpEquationFit.rb +84 -16
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingWaterToAirHeatPumpEquationFit.rb +61 -10
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ControllerWaterCoil.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoolingTower.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Fan.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.FanZoneExhaust.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.hvac.rb +4 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +43 -30
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.swh.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +18 -11
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +774 -117
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +340 -481
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.utilities.rb +3 -3
- data/lib/openstudio-standards/prototypes/common/prototype_metaprogramming.rb +22 -22
- data/lib/openstudio-standards/prototypes/deer/deer.Model.rb +1 -1
- data/lib/openstudio-standards/qaqc/calibration.rb +131 -0
- data/lib/openstudio-standards/qaqc/create_results.rb +983 -0
- data/lib/openstudio-standards/qaqc/envelope.rb +399 -0
- data/lib/openstudio-standards/qaqc/eui.rb +213 -0
- data/lib/openstudio-standards/qaqc/hvac.rb +1943 -0
- data/lib/openstudio-standards/qaqc/internal_loads.rb +568 -0
- data/lib/openstudio-standards/qaqc/reporting.rb +141 -0
- data/lib/openstudio-standards/qaqc/schedules.rb +129 -0
- data/lib/openstudio-standards/qaqc/service_water_heating.rb +273 -0
- data/lib/openstudio-standards/qaqc/weather_files.rb +497 -0
- data/lib/openstudio-standards/qaqc/zone_conditions.rb +278 -0
- data/lib/openstudio-standards/schedules/create.rb +364 -0
- data/lib/openstudio-standards/schedules/information.rb +169 -0
- data/lib/openstudio-standards/schedules/modify.rb +445 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +110 -71
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctVAVReheat.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.BoilerHotWater.rb +2 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +16 -10
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +17 -18
- data/lib/openstudio-standards/standards/Standards.CoolingTower.rb +6 -6
- data/lib/openstudio-standards/standards/Standards.CoolingTowerSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Fan.rb +6 -12
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.FluidCooler.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeaderedPumpsVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Model.rb +411 -261
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +94 -29
- data/lib/openstudio-standards/standards/Standards.Pump.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +14 -14
- data/lib/openstudio-standards/standards/Standards.Space.rb +37 -30
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +38 -29
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +7 -7
- data/lib/openstudio-standards/standards/Standards.Surface.rb +13 -13
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +109 -66
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +11 -4
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.Space.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Model.rb +5 -21
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirLoopHVAC.rb +36 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/comstock_ashrae_90_1_2016/comstock_ashrae_90_1_2016.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirLoopHVAC.rb +53 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.ZoneHVACComponent.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/comstock_ashrae_90_1_2019/comstock_ashrae_90_1_2019.AirLoopHVAC.rb +26 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +211 -211
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.economizers.json +14 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.AirLoopHVAC.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirLoopHVAC.rb +22 -28
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctParallelPIUReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.AirTerminalSingleDuctVAVReheat.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.BoilerHotWater.rb +1 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ChillerElectricEIR.rb +7 -59
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -21
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.DesignSpecificationOutdoorAir.rb +101 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanConstantVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanOnOff.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +643 -526
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlanarSurface.rb +8 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.PlantLoop.rb +17 -77
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Space.rb +74 -16
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.SpaceType.rb +96 -44
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Surface.rb +6 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ThermalZone.rb +18 -6
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.ZoneHVACComponent.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.rb +328 -74
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.Model.rb +0 -118
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/ashrae_90_1_prm_2019.rb +2 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_rejection.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/baseline_outdoor_air.md +35 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/docs/set_plug_load_measures.md +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +228 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_enums.rb +131 -0
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/userdata_space.csv +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb +5 -5
- data/lib/openstudio-standards/standards/cbes/cbes.Model.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2005/cbes_t24_2005.Space.rb +1 -1
- data/lib/openstudio-standards/standards/cbes/cbes_t24_2008/cbes_t24_2008.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer.AirLoopHVAC.rb +109 -27
- data/lib/openstudio-standards/standards/deer/deer.Space.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2003/deer_2003.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2007/deer_2007.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.economizers.json +246 -4
- data/lib/openstudio-standards/standards/deer/deer_2011/deer_2011.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2014/deer_2014.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2015/deer_2015.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2017/deer_2017.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.AirLoopHVAC.rb +18 -5
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2020/deer_2020.ThermalZone.rb +18 -18
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2025/deer_2025.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps.json +2 -2
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2030/deer_2030.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2035/deer_2035.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2040/deer_2040.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.economizers.json +260 -0
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2045/deer_2045.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2050/deer_2050.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2055/deer_2055.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2060/deer_2060.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2065/deer_2065.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2070/deer_2070.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.economizers.json +248 -6
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.AirLoopHVAC.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.FanVariableVolume.rb +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2075/deer_2075.Space.rb +3 -3
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.economizers.json +246 -4
- data/lib/openstudio-standards/standards/necb/BTAP1980TO2010/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_systems.rb +5 -2
- data/lib/openstudio-standards/standards/necb/ECMS/data/chiller_types.json +25 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/chillers.json +44 -0
- data/lib/openstudio-standards/standards/necb/ECMS/data/curves.json +225 -0
- data/lib/openstudio-standards/standards/necb/ECMS/ecms.rb +2 -2
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +193 -73
- data/lib/openstudio-standards/standards/necb/ECMS/pv_ground.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +10 -4
- data/lib/openstudio-standards/standards/necb/NECB2011/beps_compliance_path.rb +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/building_envelope.rb +4 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chiller_types.json +32 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/chillers.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +36 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernEducation.osm +47587 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/NorthernHealthCare.osm +49764 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Warehouse.osm +283 -297
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_type_unit_definitions.txt +2 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +447 -223
- data/lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +49 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +400 -202
- data/lib/openstudio-standards/standards/necb/NECB2011/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +18 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/necb_2015.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +637 -318
- data/lib/openstudio-standards/standards/necb/NECB2017/hvac_systems.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2017/necb_2017.rb +3 -3
- data/lib/openstudio-standards/standards/necb/NECB2020/building_envelope.rb +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2020/data/space_types.json +615 -307
- data/lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb +4 -4
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +10 -5
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +1 -1
- data/lib/openstudio-standards/utilities/assertion.rb +128 -0
- data/lib/openstudio-standards/utilities/logging.rb +2 -3
- data/lib/openstudio-standards/utilities/object_info.rb +39 -18
- data/lib/openstudio-standards/utilities/schedule_translator.rb +8 -6
- data/lib/openstudio-standards/utilities/simulation.rb +24 -11
- data/lib/openstudio-standards/utilities/sqlfile.rb +10 -5
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +8 -9
- data/lib/openstudio-standards/weather/Weather.stat_file.rb +3 -3
- data/lib/openstudio-standards/weather/information.rb +35 -0
- data/lib/openstudio-standards.rb +69 -5
- metadata +52 -16
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +0 -59
- data/lib/openstudio-standards/hvac_sizing/Siz.CoilCoolingWater.rb +0 -13
- data/lib/openstudio-standards/hvac_sizing/Siz.HVACComponent.rb +0 -36
- data/lib/openstudio-standards/hvac_sizing/Siz.HeatingCoolingFuels.rb +0 -898
- data/lib/openstudio-standards/hvac_sizing/Siz.Model.rb +0 -126
- data/lib/openstudio-standards/hvac_sizing/Siz.ThermalZone.rb +0 -356
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +0 -35
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTower.rb +0 -110
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoolingTowerVariableSpeed.rb +0 -5
@@ -0,0 +1,462 @@
|
|
1
|
+
# Methods to get information about model geometry
|
2
|
+
# Many of these methods may be moved to core OpenStudio
|
3
|
+
module OpenstudioStandards
|
4
|
+
module Geometry
|
5
|
+
# @!group Information
|
6
|
+
|
7
|
+
# calculate aspect ratio from area and perimeter
|
8
|
+
#
|
9
|
+
# @param area [Double] area
|
10
|
+
# @param perimeter [Double] perimeter
|
11
|
+
# @return [Double] aspect ratio
|
12
|
+
def self.aspect_ratio(area, perimeter)
|
13
|
+
length = 0.25 * (perimeter + Math.sqrt(perimeter**2 - 16 * area))
|
14
|
+
width = 0.25 * (perimeter - Math.sqrt(perimeter**2 - 16 * area))
|
15
|
+
aspect_ratio = length / width
|
16
|
+
|
17
|
+
return aspect_ratio
|
18
|
+
end
|
19
|
+
|
20
|
+
# @!endgroup Information
|
21
|
+
|
22
|
+
# @!group Information:Surfaces
|
23
|
+
|
24
|
+
# return an array of z values for surfaces passed in. The values will be relative to the parent origin.
|
25
|
+
#
|
26
|
+
# @param surfaces [Array<OpenStudio::Model::Surface>] array of Surface objects
|
27
|
+
# @return [Array<Double>] array of z values in meters
|
28
|
+
def self.surfaces_get_z_values(surfaces)
|
29
|
+
z_values = []
|
30
|
+
|
31
|
+
# loop over all surfaces
|
32
|
+
surfaces.each do |surface|
|
33
|
+
# get the existing vertices
|
34
|
+
vertices = surface.vertices
|
35
|
+
vertices.each do |vertex|
|
36
|
+
# push z value to array
|
37
|
+
z_values << vertex.z
|
38
|
+
end
|
39
|
+
end
|
40
|
+
|
41
|
+
return z_values
|
42
|
+
end
|
43
|
+
|
44
|
+
# Check if a point is contained on any surface in an array of surfaces
|
45
|
+
#
|
46
|
+
# @param surfaces [Array<OpenStudio::Model::Surface>] array of Surface objects
|
47
|
+
# @param point [OpenStudio::Point3d] Point3d object
|
48
|
+
# @return [Boolean] true if on a surface in surface array, false if not
|
49
|
+
def self.surfaces_contain_point?(surfaces, point)
|
50
|
+
on_surface = false
|
51
|
+
|
52
|
+
surfaces.each do |surface|
|
53
|
+
# Check if sensor is on floor plane (I need to loop through all floors)
|
54
|
+
plane = surface.plane
|
55
|
+
point_on_plane = plane.project(point)
|
56
|
+
|
57
|
+
face_transform = OpenStudio::Transformation.alignFace(surface.vertices)
|
58
|
+
face_vertices = face_transform * surface.vertices
|
59
|
+
face_point_on_plane = face_transform * point_on_plane
|
60
|
+
|
61
|
+
if OpenStudio.pointInPolygon(face_point_on_plane, face_vertices.reverse, 0.01)
|
62
|
+
# initial_sensor location lands in this surface's polygon
|
63
|
+
on_surface = true
|
64
|
+
end
|
65
|
+
end
|
66
|
+
|
67
|
+
return on_surface
|
68
|
+
end
|
69
|
+
|
70
|
+
# @!endgroup Information:Surfaces
|
71
|
+
|
72
|
+
# @!group Information:Space
|
73
|
+
|
74
|
+
# @!endgroup Information:Space
|
75
|
+
|
76
|
+
# @!group Information:Spaces
|
77
|
+
|
78
|
+
# Get the total floor area of selected spaces
|
79
|
+
#
|
80
|
+
# @param spaces [Array<OpenStudio::Model::Space>] array of Space objects
|
81
|
+
# @param multiplier [Boolean] account for space multiplier
|
82
|
+
# @return [Double] total floor area of spaces in square meters
|
83
|
+
def self.spaces_get_floor_area(spaces, multiplier: true)
|
84
|
+
total_area = 0.0
|
85
|
+
spaces.each do |space|
|
86
|
+
space_multiplier = multiplier ? space.multiplier : 1.0
|
87
|
+
total_area += space.floorArea * space_multiplier
|
88
|
+
end
|
89
|
+
return total_area
|
90
|
+
end
|
91
|
+
|
92
|
+
# Get the total exterior area of selected spaces
|
93
|
+
#
|
94
|
+
# @param spaces [Array<OpenStudio::Model::Space>] array of Space objects
|
95
|
+
# @param multiplier [Boolean] account for space multiplier
|
96
|
+
# @return [Double] total exterior area of spaces in square meters
|
97
|
+
def self.spaces_get_exterior_area(spaces, multiplier: true)
|
98
|
+
total_area = 0.0
|
99
|
+
spaces.each do |space|
|
100
|
+
space_multiplier = multiplier ? space.multiplier : 1.0
|
101
|
+
total_area += space.exteriorArea * space_multiplier
|
102
|
+
end
|
103
|
+
return total_area
|
104
|
+
end
|
105
|
+
|
106
|
+
# Get the total exterior wall area of selected spaces
|
107
|
+
#
|
108
|
+
# @param spaces [Array<OpenStudio::Model::Space>] array of Space objects
|
109
|
+
# @param multiplier [Boolean] account for space multiplier
|
110
|
+
# @return [Double] total exterior wall area of spaces in square meters
|
111
|
+
def self.spaces_get_exterior_wall_area(spaces, multiplier: true)
|
112
|
+
total_area = 0.0
|
113
|
+
spaces.each do |space|
|
114
|
+
space_multiplier = multiplier ? space.multiplier : 1.0
|
115
|
+
total_area += space.exteriorWallArea * space_multiplier
|
116
|
+
end
|
117
|
+
return total_area
|
118
|
+
end
|
119
|
+
|
120
|
+
# @!endgroup Information:Spaces
|
121
|
+
|
122
|
+
# @!group Information:Story
|
123
|
+
|
124
|
+
# Calculate the story exterior wall perimeter. Selected story should have above grade walls. If not perimeter may return zero.
|
125
|
+
#
|
126
|
+
# @param story [OpenStudio::Model::BuildingStory]
|
127
|
+
# @param multiplier_adjustment [Double] Adjust the calculated perimeter to account for zone multipliers. The value represents the story_multiplier which reduces the adjustment by that factor over the full zone multiplier.
|
128
|
+
# @param exterior_boundary_conditions [Array<String>] Array of strings of exterior boundary conditions.
|
129
|
+
# @param bounding_box [OpenStudio::BoundingBox] bounding box to determine which spaces are included
|
130
|
+
# @todo this doesn't catch walls that are split that sit above floor surfaces that are not (e.g. main corridoor in secondary school model)
|
131
|
+
# @todo also odd with multi-height spaces
|
132
|
+
def self.story_get_exterior_wall_perimeter(story,
|
133
|
+
multiplier_adjustment: nil,
|
134
|
+
exterior_boundary_conditions: ['Outdoors', 'Ground'],
|
135
|
+
bounding_box: nil)
|
136
|
+
perimeter = 0
|
137
|
+
party_walls = []
|
138
|
+
story.spaces.each do |space|
|
139
|
+
# counter to use later
|
140
|
+
edge_hash = {}
|
141
|
+
edge_counter = 0
|
142
|
+
space.surfaces.each do |surface|
|
143
|
+
# get vertices
|
144
|
+
vertex_hash = {}
|
145
|
+
vertex_counter = 0
|
146
|
+
surface.vertices.each do |vertex|
|
147
|
+
vertex_counter += 1
|
148
|
+
vertex_hash[vertex_counter] = [vertex.x, vertex.y, vertex.z]
|
149
|
+
end
|
150
|
+
# make edges
|
151
|
+
counter = 0
|
152
|
+
vertex_hash.each do |k, v|
|
153
|
+
edge_counter += 1
|
154
|
+
counter += 1
|
155
|
+
if vertex_hash.size != counter
|
156
|
+
edge_hash[edge_counter] = [v, vertex_hash[counter + 1], surface, surface.outsideBoundaryCondition, surface.surfaceType]
|
157
|
+
else # different code for wrap around vertex
|
158
|
+
edge_hash[edge_counter] = [v, vertex_hash[1], surface, surface.outsideBoundaryCondition, surface.surfaceType]
|
159
|
+
end
|
160
|
+
end
|
161
|
+
end
|
162
|
+
|
163
|
+
# check edges for matches (need opposite vertices and proper boundary conditions)
|
164
|
+
edge_hash.each do |k1, v1|
|
165
|
+
# apply to any floor boundary condition. This supports used in floors above basements
|
166
|
+
next if v1[4] != 'Floor'
|
167
|
+
|
168
|
+
edge_hash.each do |k2, v2|
|
169
|
+
test_boundary_cond = false
|
170
|
+
next if !exterior_boundary_conditions.include?(v2[3]) # method arg takes multiple conditions
|
171
|
+
next if v2[4] != 'Wall'
|
172
|
+
|
173
|
+
# see if edges have same geometry
|
174
|
+
|
175
|
+
# found cases where the two lines below removed edges and resulted in lower than actual perimeter. Added new code with tolerance.
|
176
|
+
# next if not v1[0] == v2[1] # next if not same geometry reversed
|
177
|
+
# next if not v1[1] == v2[0]
|
178
|
+
|
179
|
+
# these are three item array's add in tollerance for each array entry
|
180
|
+
tolerance = 0.0001
|
181
|
+
test_a = true
|
182
|
+
test_b = true
|
183
|
+
3.times.each do |i|
|
184
|
+
if (v1[0][i] - v2[1][i]).abs > tolerance
|
185
|
+
test_a = false
|
186
|
+
end
|
187
|
+
if (v1[1][i] - v2[0][i]).abs > tolerance
|
188
|
+
test_b = false
|
189
|
+
end
|
190
|
+
end
|
191
|
+
|
192
|
+
next if test_a != true
|
193
|
+
next if test_b != true
|
194
|
+
|
195
|
+
# edge_bounding_box = OpenStudio::BoundingBox.new
|
196
|
+
# edge_bounding_box.addPoints(space.transformation() * v2[2].vertices)
|
197
|
+
# if not edge_bounding_box.intersects(bounding_box) doesn't seem to work reliably, writing custom code to check
|
198
|
+
|
199
|
+
point_one = OpenStudio::Point3d.new(v2[0][0], v2[0][1], v2[0][2])
|
200
|
+
point_one = (space.transformation * point_one)
|
201
|
+
point_two = OpenStudio::Point3d.new(v2[1][0], v2[1][1], v2[1][2])
|
202
|
+
point_two = (space.transformation * point_two)
|
203
|
+
|
204
|
+
if !bounding_box.nil? && (v2[3] == 'Adiabatic')
|
205
|
+
|
206
|
+
on_bounding_box = false
|
207
|
+
if ((bounding_box.minX.to_f - point_one.x).abs < tolerance) && ((bounding_box.minX.to_f - point_two.x).abs < tolerance)
|
208
|
+
on_bounding_box = true
|
209
|
+
elsif ((bounding_box.maxX.to_f - point_one.x).abs < tolerance) && ((bounding_box.maxX.to_f - point_two.x).abs < tolerance)
|
210
|
+
on_bounding_box = true
|
211
|
+
elsif ((bounding_box.minY.to_f - point_one.y).abs < tolerance) && ((bounding_box.minY.to_f - point_two.y).abs < tolerance)
|
212
|
+
on_bounding_box = true
|
213
|
+
elsif ((bounding_box.maxY.to_f - point_one.y).abs < tolerance) && ((bounding_box.maxY.to_f - point_two.y).abs < tolerance)
|
214
|
+
on_bounding_box = true
|
215
|
+
end
|
216
|
+
|
217
|
+
# if not edge_bounding_box.intersects(bounding_box) doesn't seem to work reliably, writing custom code to check
|
218
|
+
# todo - this is basic check for adiabatic party walls and won't catch all situations. Can be made more robust in the future
|
219
|
+
if on_bounding_box == true
|
220
|
+
length = OpenStudio::Vector3d.new(point_one - point_two).length
|
221
|
+
party_walls << v2[2]
|
222
|
+
length_ip_display = OpenStudio.convert(length, 'm', 'ft').get.round(2)
|
223
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Geometry.Create', " * #{v2[2].name} has an adiabatic boundary condition and sits in plane with the building bounding box. Adding #{length_ip_display} (ft) to perimeter length of #{story.name} for this surface, assuming it is a party wall.")
|
224
|
+
elsif space.multiplier == 1
|
225
|
+
length = OpenStudio::Vector3d.new(point_one - point_two).length
|
226
|
+
party_walls << v2[2]
|
227
|
+
length_ip_display = OpenStudio.convert(length, 'm', 'ft').get.round(2)
|
228
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.Geometry.Create', " * #{v2[2].name} has an adiabatic boundary condition and is in a zone with a multiplier of 1. Adding #{length_ip_display} (ft) to perimeter length of #{story.name} for this surface, assuming it is a party wall.")
|
229
|
+
else
|
230
|
+
length = 0
|
231
|
+
end
|
232
|
+
|
233
|
+
else
|
234
|
+
length = OpenStudio::Vector3d.new(point_one - point_two).length
|
235
|
+
end
|
236
|
+
|
237
|
+
if multiplier_adjustment.nil?
|
238
|
+
perimeter += length
|
239
|
+
else
|
240
|
+
# adjust for multiplier
|
241
|
+
non_story_multiplier = space.multiplier / multiplier_adjustment.to_f
|
242
|
+
perimeter += length * non_story_multiplier
|
243
|
+
end
|
244
|
+
end
|
245
|
+
end
|
246
|
+
end
|
247
|
+
|
248
|
+
return { perimeter: perimeter, party_walls: party_walls }
|
249
|
+
end
|
250
|
+
|
251
|
+
# @!endgroup Information:Story
|
252
|
+
|
253
|
+
# @!group Information:Model
|
254
|
+
|
255
|
+
# Returns the window to wall ratio
|
256
|
+
#
|
257
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
258
|
+
# @param spaces [Array<OpenStudio::Model::Space>] optional array of Space objects.
|
259
|
+
# If provided, the return will report for only those spaces.
|
260
|
+
# @return [Double] window to wall ratio
|
261
|
+
def self.model_get_exterior_window_to_wall_ratio(model, spaces: [])
|
262
|
+
# counters
|
263
|
+
total_gross_ext_wall_area = 0
|
264
|
+
total_ext_window_area = 0
|
265
|
+
|
266
|
+
if spaces.empty?
|
267
|
+
spaces = model.getSpaces
|
268
|
+
end
|
269
|
+
|
270
|
+
spaces.each do |space|
|
271
|
+
# get surface area adjusting for zone multiplier
|
272
|
+
zone = space.thermalZone
|
273
|
+
if !zone.empty?
|
274
|
+
zone_multiplier = zone.get.multiplier
|
275
|
+
if zone_multiplier > 1
|
276
|
+
end
|
277
|
+
else
|
278
|
+
zone_multiplier = 1 # space is not in a thermal zone
|
279
|
+
end
|
280
|
+
|
281
|
+
space.surfaces.each do |s|
|
282
|
+
next if s.surfaceType != 'Wall'
|
283
|
+
next if s.outsideBoundaryCondition != 'Outdoors'
|
284
|
+
|
285
|
+
surface_gross_area = s.grossArea * zone_multiplier
|
286
|
+
|
287
|
+
# loop through sub surfaces and add area including multiplier
|
288
|
+
ext_window_area = 0
|
289
|
+
s.subSurfaces.each do |sub_surface|
|
290
|
+
ext_window_area += sub_surface.grossArea * sub_surface.multiplier * zone_multiplier
|
291
|
+
end
|
292
|
+
|
293
|
+
total_gross_ext_wall_area += surface_gross_area
|
294
|
+
total_ext_window_area += ext_window_area
|
295
|
+
end
|
296
|
+
end
|
297
|
+
|
298
|
+
if total_gross_ext_wall_area > 0
|
299
|
+
result = total_ext_window_area / total_gross_ext_wall_area
|
300
|
+
else
|
301
|
+
result = 0.0
|
302
|
+
end
|
303
|
+
|
304
|
+
return result
|
305
|
+
end
|
306
|
+
|
307
|
+
# Returns the wall area and window area by orientation
|
308
|
+
#
|
309
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
310
|
+
# @param spaces [Array<OpenStudio::Model::Space>] optional array of Space objects.
|
311
|
+
# If provided, the return will report for only those spaces.
|
312
|
+
# @return [Hash] Hash of wall area in square meters and window to wall ratio for each orientation
|
313
|
+
def self.model_get_exterior_window_and_wall_area_by_orientation(model, spaces: [])
|
314
|
+
# counters
|
315
|
+
total_gross_ext_wall_area_north = 0.0
|
316
|
+
total_gross_ext_wall_area_south = 0.0
|
317
|
+
total_gross_ext_wall_area_east = 0.0
|
318
|
+
total_gross_ext_wall_area_west = 0.0
|
319
|
+
total_ext_window_area_north = 0.0
|
320
|
+
total_ext_window_area_south = 0.0
|
321
|
+
total_ext_window_area_east = 0.0
|
322
|
+
total_ext_window_area_west = 0.0
|
323
|
+
|
324
|
+
if spaces.empty?
|
325
|
+
spaces = model.getSpaces
|
326
|
+
end
|
327
|
+
|
328
|
+
spaces.each do |space|
|
329
|
+
# get surface area adjusting for zone multiplier
|
330
|
+
zone = space.thermalZone
|
331
|
+
if !zone.empty?
|
332
|
+
zone_multiplier = zone.get.multiplier
|
333
|
+
if zone_multiplier > 1
|
334
|
+
end
|
335
|
+
else
|
336
|
+
zone_multiplier = 1 # space is not in a thermal zone
|
337
|
+
end
|
338
|
+
|
339
|
+
space.surfaces.each do |s|
|
340
|
+
next if s.surfaceType != 'Wall'
|
341
|
+
next if s.outsideBoundaryCondition != 'Outdoors'
|
342
|
+
|
343
|
+
surface_gross_area = s.grossArea * zone_multiplier
|
344
|
+
|
345
|
+
# loop through sub surfaces and add area including multiplier
|
346
|
+
ext_window_area = 0
|
347
|
+
s.subSurfaces.each do |sub_surface|
|
348
|
+
ext_window_area += sub_surface.grossArea * sub_surface.multiplier * zone_multiplier
|
349
|
+
end
|
350
|
+
|
351
|
+
absolute_azimuth = OpenStudio.convert(s.azimuth, 'rad', 'deg').get + s.space.get.directionofRelativeNorth + model.getBuilding.northAxis
|
352
|
+
absolute_azimuth -= 360.0 until absolute_azimuth < 360.0
|
353
|
+
|
354
|
+
# add to exterior wall counter if north or south
|
355
|
+
if (absolute_azimuth >= 45.0) && (absolute_azimuth < 125.0)
|
356
|
+
# east exterior walls
|
357
|
+
total_gross_ext_wall_area_east += surface_gross_area
|
358
|
+
total_ext_window_area_east += ext_window_area
|
359
|
+
elsif (absolute_azimuth >= 125.0) && (absolute_azimuth < 225.0)
|
360
|
+
# south exterior walls
|
361
|
+
total_gross_ext_wall_area_south += surface_gross_area
|
362
|
+
total_ext_window_area_south += ext_window_area
|
363
|
+
elsif (absolute_azimuth >= 225.0) && (absolute_azimuth < 315.0)
|
364
|
+
# west exterior walls
|
365
|
+
total_gross_ext_wall_area_west += surface_gross_area
|
366
|
+
total_ext_window_area_west += ext_window_area
|
367
|
+
else
|
368
|
+
# north exterior walls
|
369
|
+
total_gross_ext_wall_area_north += surface_gross_area
|
370
|
+
total_ext_window_area_north += ext_window_area
|
371
|
+
end
|
372
|
+
end
|
373
|
+
end
|
374
|
+
|
375
|
+
result = { 'north_wall' => total_gross_ext_wall_area_north,
|
376
|
+
'north_window' => total_ext_window_area_north,
|
377
|
+
'south_wall' => total_gross_ext_wall_area_south,
|
378
|
+
'south_window' => total_ext_window_area_south,
|
379
|
+
'east_wall' => total_gross_ext_wall_area_east,
|
380
|
+
'east_window' => total_ext_window_area_east,
|
381
|
+
'west_wall' => total_gross_ext_wall_area_west,
|
382
|
+
'west_window' => total_ext_window_area_west }
|
383
|
+
return result
|
384
|
+
end
|
385
|
+
|
386
|
+
# Calculates the exterior perimeter length, checking checks for edges shared by a ground exposed floor and exterior exposed wall.
|
387
|
+
#
|
388
|
+
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
389
|
+
# @return [Double] perimeter length in meters
|
390
|
+
# @todo this doesn't catch walls that are split that sit above floor surfaces that are not (e.g. main corridoor in secondary school model)
|
391
|
+
# @todo also odd with multi-height spaces
|
392
|
+
def self.model_get_perimeter_length(model)
|
393
|
+
perimeter = 0.0
|
394
|
+
model.getSpaces.sort.each do |space|
|
395
|
+
# counter to use later
|
396
|
+
edge_hash = {}
|
397
|
+
edge_counter = 0
|
398
|
+
space.surfaces.sort.each do |surface|
|
399
|
+
# get vertices
|
400
|
+
vertex_hash = {}
|
401
|
+
vertex_counter = 0
|
402
|
+
surface.vertices.each do |vertex|
|
403
|
+
vertex_counter += 1
|
404
|
+
vertex_hash[vertex_counter] = [vertex.x, vertex.y, vertex.z]
|
405
|
+
end
|
406
|
+
# make edges
|
407
|
+
counter = 0
|
408
|
+
vertex_hash.each do |k, v|
|
409
|
+
edge_counter += 1
|
410
|
+
counter += 1
|
411
|
+
if vertex_hash.size != counter
|
412
|
+
edge_hash[edge_counter] = [v, vertex_hash[counter + 1], surface, surface.outsideBoundaryCondition, surface.surfaceType]
|
413
|
+
else # different code for wrap around vertex
|
414
|
+
edge_hash[edge_counter] = [v, vertex_hash[1], surface, surface.outsideBoundaryCondition, surface.surfaceType]
|
415
|
+
end
|
416
|
+
end
|
417
|
+
end
|
418
|
+
|
419
|
+
# check edges for matches (need opposite vertices and proper boundary conditions)
|
420
|
+
edge_hash.each do |k1, v1|
|
421
|
+
next if v1[3] != 'Ground' # skip if not ground exposed floor
|
422
|
+
next if v1[4] != 'Floor'
|
423
|
+
|
424
|
+
edge_hash.each do |k2, v2|
|
425
|
+
next if v2[3] != 'Outdoors' # skip if not exterior exposed wall (todo - update to handle basement)
|
426
|
+
next if v2[4] != 'Wall'
|
427
|
+
|
428
|
+
# see if edges have same geometry
|
429
|
+
# found cases where the two lines below removed edges and resulted in lower than actual perimeter. Added new code with tolerance.
|
430
|
+
# next if not v1[0] == v2[1] # next if not same geometry reversed
|
431
|
+
# next if not v1[1] == v2[0]
|
432
|
+
|
433
|
+
# these are three item array's add in tollerance for each array entry
|
434
|
+
tolerance = 0.0001
|
435
|
+
test_a = true
|
436
|
+
test_b = true
|
437
|
+
3.times.each do |i|
|
438
|
+
if (v1[0][i] - v2[1][i]).abs > tolerance
|
439
|
+
test_a = false
|
440
|
+
end
|
441
|
+
if (v1[1][i] - v2[0][i]).abs > tolerance
|
442
|
+
test_b = false
|
443
|
+
end
|
444
|
+
end
|
445
|
+
|
446
|
+
next if test_a != true
|
447
|
+
next if test_b != true
|
448
|
+
|
449
|
+
point_one = OpenStudio::Point3d.new(v1[0][0], v1[0][1], v1[0][2])
|
450
|
+
point_two = OpenStudio::Point3d.new(v1[1][0], v1[1][1], v1[1][2])
|
451
|
+
length = OpenStudio::Vector3d.new(point_one - point_two).length
|
452
|
+
perimeter += length
|
453
|
+
end
|
454
|
+
end
|
455
|
+
end
|
456
|
+
|
457
|
+
return perimeter
|
458
|
+
end
|
459
|
+
|
460
|
+
# @!endgroup Information:Model
|
461
|
+
end
|
462
|
+
end
|
@@ -0,0 +1,48 @@
|
|
1
|
+
# Methods to modify geometry
|
2
|
+
module OpenstudioStandards
|
3
|
+
module Geometry
|
4
|
+
# @!group Modify
|
5
|
+
|
6
|
+
# lower z value of vertices with starting value above z_value_target to z_value_target
|
7
|
+
#
|
8
|
+
# @param surfaces [Array<OpenStudio::Model::Surface>] array of Surface objects
|
9
|
+
# @param z_value_target [Double]
|
10
|
+
# @return [Array] array of z values in meters
|
11
|
+
def self.surfaces_lower_z_values(surfaces, z_value_target)
|
12
|
+
count = 0
|
13
|
+
|
14
|
+
# loop over all surfaces
|
15
|
+
surfaces.each do |surface|
|
16
|
+
# create a new set of vertices
|
17
|
+
new_vertices = OpenStudio::Point3dVector.new
|
18
|
+
|
19
|
+
# get the existing vertices for this interior partition
|
20
|
+
vertices = surface.vertices
|
21
|
+
flag = false
|
22
|
+
vertices.each do |vertex|
|
23
|
+
# initialize new vertex to old vertex
|
24
|
+
x = vertex.x
|
25
|
+
y = vertex.y
|
26
|
+
z = vertex.z
|
27
|
+
|
28
|
+
# if this z vertex is not on the z = 0 plane
|
29
|
+
if z > z_value_target
|
30
|
+
z = z_value_target
|
31
|
+
flag = true
|
32
|
+
end
|
33
|
+
|
34
|
+
# add point to new vertices
|
35
|
+
new_vertices << OpenStudio::Point3d.new(x, y, z)
|
36
|
+
end
|
37
|
+
|
38
|
+
# set vertices to new vertices
|
39
|
+
# @todo check if this was made, and issue warning if it was not. Could happen if resulting surface not planer.
|
40
|
+
surface.setVertices(new_vertices)
|
41
|
+
|
42
|
+
count += 1 if flag
|
43
|
+
end
|
44
|
+
|
45
|
+
return count
|
46
|
+
end
|
47
|
+
end
|
48
|
+
end
|
@@ -0,0 +1,79 @@
|
|
1
|
+
# Method to apply a typical CBECS HVAC system to thermal zones
|
2
|
+
module OpenstudioStandards
|
3
|
+
module HVAC
|
4
|
+
# @!group AirLoop:Information
|
5
|
+
|
6
|
+
# Returns whether air loop HVAC is a direct evaporative system
|
7
|
+
#
|
8
|
+
# @param air_loop_hvac [<OpenStudio::Model::AirLoopHVAC>] OpenStudio AirLoopHVAC object
|
9
|
+
# @return [Bool] returns true if successful, false if not
|
10
|
+
def self.air_loop_hvac_direct_evap?(air_loop_hvac)
|
11
|
+
# check if direct evap
|
12
|
+
is_direct_evap = false
|
13
|
+
air_loop_hvac.supplyComponents.each do |component|
|
14
|
+
# Get the object type
|
15
|
+
obj_type = component.iddObjectType.valueName.to_s
|
16
|
+
case obj_type
|
17
|
+
when 'OS_EvaporativeCooler_Direct_ResearchSpecial', 'OS_EvaporativeCooler_Indirect_ResearchSpecial'
|
18
|
+
is_direct_evap = true
|
19
|
+
end
|
20
|
+
end
|
21
|
+
return is_direct_evap
|
22
|
+
end
|
23
|
+
|
24
|
+
# Returns whether air loop HVAC is a unitary system
|
25
|
+
#
|
26
|
+
# @param air_loop_hvac [<OpenStudio::Model::AirLoopHVAC>] OpenStudio AirLoopHVAC object
|
27
|
+
# @return [Bool] returns true if air_loop_hvac is a unitary system, false if not
|
28
|
+
def self.air_loop_hvac_unitary_system?(air_loop_hvac)
|
29
|
+
# check if unitary system
|
30
|
+
is_unitary_system = false
|
31
|
+
air_loop_hvac.supplyComponents.each do |component|
|
32
|
+
# Get the object type
|
33
|
+
obj_type = component.iddObjectType.valueName.to_s
|
34
|
+
case obj_type
|
35
|
+
when 'OS_AirLoopHVAC_UnitarySystem', 'OS_AirLoopHVAC_UnitaryHeatPump_AirToAir', 'OS_AirLoopHVAC_UnitaryHeatPump_AirToAir_MultiSpeed', 'OS_AirLoopHVAC_UnitaryHeatCool_VAVChangeoverBypass'
|
36
|
+
is_unitary_system = true
|
37
|
+
end
|
38
|
+
end
|
39
|
+
return is_unitary_system
|
40
|
+
end
|
41
|
+
|
42
|
+
# Returns the unitary system minimum and maximum design temperatures
|
43
|
+
#
|
44
|
+
# @param unitary_system [<OpenStudio::Model::ModelObject>] OpenStudio ModelObject object
|
45
|
+
# @return [Hash] returns as hash with 'min_temp' and 'max_temp' in degrees Fahrenheit
|
46
|
+
def self.unitary_system_min_max_temperature_value(unitary_system)
|
47
|
+
min_temp = nil
|
48
|
+
max_temp = nil
|
49
|
+
# Get the object type
|
50
|
+
obj_type = unitary_system.iddObjectType.valueName.to_s
|
51
|
+
case obj_type
|
52
|
+
when 'OS_AirLoopHVAC_UnitarySystem'
|
53
|
+
unitary_system = unitary_system.to_AirLoopHVACUnitarySystem.get
|
54
|
+
if unitary_system.useDOASDXCoolingCoil
|
55
|
+
min_temp = OpenStudio.convert(unitary_system.dOASDXCoolingCoilLeavingMinimumAirTemperature, 'C', 'F').get
|
56
|
+
end
|
57
|
+
if unitary_system.maximumSupplyAirTemperature.is_initialized
|
58
|
+
max_temp = OpenStudio.convert(unitary_system.maximumSupplyAirTemperature.get, 'C', 'F').get
|
59
|
+
end
|
60
|
+
when 'OS_AirLoopHVAC_UnitaryHeatPump_AirToAir'
|
61
|
+
unitary_system = unitary_system.to_AirLoopHVACUnitaryHeatPumpAirToAir.get
|
62
|
+
if unitary_system.maximumSupplyAirTemperaturefromSupplementalHeater.is_initialized
|
63
|
+
max_temp = OpenStudio.convert(unitary_system.maximumSupplyAirTemperaturefromSupplementalHeater.get, 'C', 'F').get
|
64
|
+
end
|
65
|
+
when 'OS_AirLoopHVAC_UnitaryHeatPump_AirToAir_MultiSpeed'
|
66
|
+
unitary_system = unitary_system.to_AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed.get
|
67
|
+
if unitary_system.maximumSupplyAirTemperaturefromSupplementalHeater.is_initialized
|
68
|
+
max_temp = OpenStudio.convert(unitary_system.maximumSupplyAirTemperaturefromSupplementalHeater.get, 'C', 'F').get
|
69
|
+
end
|
70
|
+
when 'OS_AirLoopHVAC_UnitaryHeatCool_VAVChangeoverBypass'
|
71
|
+
unitary_system = unitary_system.to_AirLoopHVACUnitaryHeatCoolVAVChangeoverBypass.get
|
72
|
+
min_temp = OpenStudio.convert(unitary_system.minimumOutletAirTemperatureDuringCoolingOperation, 'C', 'F').get
|
73
|
+
max_temp = OpenStudio.convert(unitary_system.maximumOutletAirTemperatureDuringHeatingOperation, 'C', 'F').get
|
74
|
+
end
|
75
|
+
|
76
|
+
return { 'min_temp' => min_temp, 'max_temp' => max_temp }
|
77
|
+
end
|
78
|
+
end
|
79
|
+