openstudio-standards 0.8.2 → 0.8.4
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +7962 -0
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +473 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/common_paths.rb +78 -0
- data/lib/openstudio-standards/btap/costing/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/costing/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/costing/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +61 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +1904 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/costing/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/costing/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_hvac.csv +1699 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +177 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +353 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +284 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +155 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +17 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +26 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/refrigeration/create_case.rb +58 -21
- data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +4 -2
- data/lib/openstudio-standards/refrigeration/create_walkin.rb +57 -22
- data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -31
- data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -76
- data/lib/openstudio-standards/service_water_heating/create_typical.rb +10 -10
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +10 -0
- data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -3
- data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +9 -9
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +49 -49
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +159 -159
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +7 -18
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +10 -20
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -15
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +5 -6
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +93 -43
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +135 -37
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Model.rb +48 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +648 -326
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +371 -90
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +1012 -296
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +443 -79
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +672 -306
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +354 -74
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +930 -604
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +415 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +602 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +1005 -333
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +642 -88
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +78 -26
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +722 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +1741 -426
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +1108 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +186 -62
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +62 -232
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +7 -18
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +154 -69
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps_heating.json +72 -72
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +382 -295
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +6 -1
- data/lib/openstudio-standards/standards/deer/data/deer.schedules.json +62 -232
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +2 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +46 -20
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +635 -248
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +43 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +43 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +214 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +8 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +15 -6
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +20 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +10 -0
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +190 -28
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +14 -5
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/utilities/simulation.rb +3 -2
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards.rb +12 -0
- metadata +56 -3
@@ -2,7 +2,7 @@ require 'openstudio'
|
|
2
2
|
require 'securerandom'
|
3
3
|
require 'optparse'
|
4
4
|
require 'yaml'
|
5
|
-
#require 'git-revision'
|
5
|
+
# require 'git-revision'
|
6
6
|
# resource_folder = File.join(__dir__, '..', '..', 'measures/btap_results/resources')
|
7
7
|
# OpenSSL::SSL::VERIFY_PEER = OpenSSL::SSL::VERIFY_NONE
|
8
8
|
|
@@ -77,7 +77,6 @@ class BTAPDatapoint
|
|
77
77
|
@dp_output_folder = File.join(output_folder, @options[:datapoint_id])
|
78
78
|
|
79
79
|
# Show versions in yml file.
|
80
|
-
@options[:btap_costing_git_revision] = Git::Revision.commit_short
|
81
80
|
@options[:os_git_revision] = OpenstudioStandards.git_revision
|
82
81
|
|
83
82
|
# Get users' inputs for the parameters needed for the calculation af net present value
|
@@ -125,7 +124,13 @@ class BTAPDatapoint
|
|
125
124
|
@standard.model_apply_standard(model: model,
|
126
125
|
epw_file: @options[:epw_file],
|
127
126
|
custom_weather_folder: weather_folder,
|
127
|
+
btap_weather: @options[:btap_weather],
|
128
128
|
sizing_run_dir: File.join(@dp_temp_folder, 'sizing_folder'),
|
129
|
+
hvac_system_primary: @options[:hvac_system_primary],
|
130
|
+
hvac_system_dwelling_units: @options[:hvac_system_dwelling_units],
|
131
|
+
hvac_system_washrooms: @options[:hvac_system_washrooms],
|
132
|
+
hvac_system_corridor: @options[:hvac_system_corridor],
|
133
|
+
hvac_system_storage: @options[:hvac_system_storage],
|
129
134
|
primary_heating_fuel: @options[:primary_heating_fuel],
|
130
135
|
necb_reference_hp: @options[:necb_reference_hp],
|
131
136
|
necb_reference_hp_supp_fuel: @options[:necb_reference_hp_supp_fuel],
|
@@ -185,6 +190,7 @@ class BTAPDatapoint
|
|
185
190
|
boiler_fuel: @options[:boiler_fuel],
|
186
191
|
boiler_cap_ratio: @options[:boiler_cap_ratio],
|
187
192
|
swh_fuel: @options[:swh_fuel],
|
193
|
+
airloop_fancoils_heating: @options[:airloop_fancoils_heating],
|
188
194
|
oerd_utility_pricing: @oerd_utility_pricing
|
189
195
|
)
|
190
196
|
end
|
@@ -241,10 +247,13 @@ class BTAPDatapoint
|
|
241
247
|
model.setSqlFile(sql)
|
242
248
|
|
243
249
|
@cost_result = nil
|
244
|
-
if
|
250
|
+
if @options[:enable_costing]
|
245
251
|
# Perform costing
|
246
|
-
|
252
|
+
costs_path = File.absolute_path(File.join(__dir__, '..','..','..','btap','costing','common_resources', 'costs.csv'))
|
253
|
+
local_cost_factors_path = File.absolute_path(File.join(__dir__, '..','..','..','btap','costing','common_resources', 'costs_local_factors.csv'))
|
254
|
+
costing = BTAPCosting.new(costs_csv: costs_path, factors_csv: local_cost_factors_path)
|
247
255
|
costing.load_database
|
256
|
+
|
248
257
|
@cost_result, @btap_items = costing.cost_audit_all(model: model, prototype_creator: @standard, template_type: @options[:template])
|
249
258
|
@qaqc[:costing_information] = @cost_result
|
250
259
|
File.open(File.join(@dp_temp_folder, 'cost_results.json'), 'w') { |f| f.write(JSON.pretty_generate(@cost_result, allow_nan: true)) }
|
@@ -618,4 +627,4 @@ class BTAPDatapoint
|
|
618
627
|
#===================================================================================================================
|
619
628
|
end #output_timestep_data
|
620
629
|
#=====================================================================================================================
|
621
|
-
end
|
630
|
+
end
|
@@ -0,0 +1,14 @@
|
|
1
|
+
province,units,2005,2006,2007,2008,2009,2010,2011,2012,2013,2014,2015,2016,2017,2018,2019,2020,2021,2022,2023,2024,2025,2026,2027,2028,2029,2030,2031,2032,2033,2034,2035,2036,2037,2038,2039,2040,2041,2042,2043,2044,2045,2046,2047,2048,2049,2050
|
2
|
+
Alberta,tCO2e/GWh,958.7,991.3,925.2,916.8,822.5,843.4,794.1,754.5,785.7,789.4,744.9,768.4,765.3,604.3,568.6,530.2,458.3,382.1,304.5,301.4,265.2,226.8,210.2,172.1,165,170.9,166.2,153.9,145,138.4,118.8,106.5,100.3,82.3,77.2,71.4,69.9,70.3,70.9,71.5,71.6,70.6,70.3,68.6,43.9,19.2
|
3
|
+
British Columbia,tCO2e/GWh,20.7,20,17,25.3,20.9,21.6,9.4,10.1,10.6,6.9,4.6,2.9,2,5.4,11.6,5.3,8.2,5.7,5.1,5.4,5.3,4.2,3.9,3.7,1.5,1.4,1.4,1.3,1.2,1.1,1,0.6,0.6,0.5,0.5,0.5,0.1,0.1,0.1,0.1,0.1,0.1,0.1,0.1,0.1,0.1
|
4
|
+
Manitoba,tCO2e/GWh,19.4,24,26.7,21,9.6,4.5,5.8,5.4,5.4,5.6,5.6,3.2,3.1,1.8,1.8,1.9,2.6,2.1,1.8,1.1,0.5,0.7,0.7,0.7,0.7,0.7,0.7,0.7,0.7,0.7,0.7,0.7,0.7,0.7,0.6,0.6,0.6,0.6,0.6,0.6,0.6,0.6,0.6,0.6,0.6,0.6
|
5
|
+
New Brunswick,tCO2e/GWh,613,595.4,539,546.9,549.6,379.4,333.2,281.4,236.6,264.7,259.4,333.3,261.1,281.6,263,182.5,264.5,291.2,298.4,295.7,319.1,306,278.1,266.1,252,37,31.8,24.8,29.1,29,46.9,52.2,65,64.4,27.8,27.7,2.9,2.5,2.5,2.4,1.9,14.3,12.5,10.6,1.2,0.9
|
6
|
+
Newfoundland and Labrador,tCO2e/GWh,85.8,64.8,106.4,90.3,89.7,76.6,81.7,79.3,86,119.8,148.3,151.8,145.1,105.9,104.7,90.3,74.2,81.4,7.6,6.3,6.3,6.2,6,5.8,6.4,5.6,5.5,5.3,5.2,5.1,5,4.8,5,5.3,5.3,5.2,5.1,4.9,4.5,4.2,4.2,4.1,4.1,4,4,3.9
|
7
|
+
Northwest Territories,tCO2e/GWh,303.6,275.4,304.7,263.2,205.1,236.3,226.1,115.4,190.2,241.7,352.2,196.2,189.8,202.7,186.1,191.8,192.6,215.5,234.9,175,1,0,0,5.2,4.6,4.1,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
|
8
|
+
Nova Scotia,tCO2e/GWh,927.2,974.9,979,803.5,817.8,741.4,743,726.4,713.3,689.9,643.5,656.2,651.2,684.4,645.1,619.3,582.9,542.4,658.1,605.3,529.8,477.9,461.9,448.1,303.9,88.2,89.7,112,105,98.4,70.6,66.7,63.2,60.5,59,57.2,55.4,46.7,45.9,63.3,60.2,57.1,53.7,50.3,47.1,38.6
|
9
|
+
Nunavut,tCO2e/GWh,606,507.6,510.1,539,566.8,566.8,482.4,484.2,453.9,567.5,481.8,607.5,574.8,675.3,673.3,616.2,639.8,628.2,788.4,724.3,494.4,456.6,442.9,444.2,456.9,454.3,466.7,410.7,425,449,401,411.4,423.9,378.1,389.3,403.4,361.2,373.9,339.2,304.3,318.7,288.9,257.7,267.9,237.4,208.7
|
10
|
+
Ontario,tCO2e/GWh,224.3,206,228.7,189,112.2,143.4,91.2,90.9,67.3,40,42.1,36,16.4,25.5,24.8,24.2,26.3,30.2,23.9,55.5,65.3,76.1,56.9,50.4,50,65,55.9,65.8,68.4,76.1,30.5,23.3,19.1,13.6,10.7,13.1,12.9,11.9,11.7,11.5,14,13.8,13.6,13.4,12.5,3.4
|
11
|
+
Prince Edward Island,tCO2e/GWh,5,8.4,4.8,4,5.3,1.6,1.1,9,3.2,3.4,11.3,3.5,6.5,2.1,0.8,0.2,1.4,0.8,0.8,0.8,0.8,0.8,0.8,0.8,0.8,0.8,0.8,0.8,0.7,0.7,0.7,0.7,0.7,0.6,0.6,0.6,0.6,0.6,0.6,0.6,0.6,0.5,0.5,0.5,0.5,0.5
|
12
|
+
Quebec,tCO2e/GWh,3.2,5.1,8.7,2.5,3.5,2.4,2.7,2.5,1.4,1.5,1.3,1.5,1.4,1.4,1.5,1.8,1.5,1.3,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0
|
13
|
+
Saskatchewan,tCO2e/GWh,860.6,813.3,803.3,769.7,872,846.4,797.5,807.8,685.2,700.2,736.8,721.4,703.2,720.6,698.5,615.7,692.9,648.2,542.8,560.6,522.9,515.3,499.4,341.2,330.8,115.3,117.1,108.6,104.3,100.3,48.7,40.4,37,34.9,52.4,58.6,62.6,57.6,53.2,40.8,23.8,23.2,22.9,22.3,21.8,12.6
|
14
|
+
Yukon,tCO2e/GWh,70,53.4,53.2,51.2,44.6,48.6,68.7,42.8,41.4,41.4,44.6,47.1,53.5,76.2,113.1,111.3,79.3,73.3,120,107.6,7,6.9,6.8,7,8.3,10.2,41.9,48,52.1,52.3,58.9,57.4,55.2,53.2,52.3,46.3,29.8,28.7,27.3,25.2,24.5,24.6,28.5,27.2,27.3,27.6
|
@@ -0,0 +1,14 @@
|
|
1
|
+
province,units,2022
|
2
|
+
Alberta,g/m3,1962
|
3
|
+
British Columbia,g/m3,1966
|
4
|
+
Manitoba,g/m3,1915
|
5
|
+
New Brunswick,g/m3,1919
|
6
|
+
Newfoundland and Labrador,g/m3,1919
|
7
|
+
Northwest Territories,g/m3,1966
|
8
|
+
Nova Scotia,g/m3,1919
|
9
|
+
Nunavut,g/m3,1966
|
10
|
+
Ontario,g/m3,1921
|
11
|
+
Prince Edward Island,g/m3,1919
|
12
|
+
Quebec,g/m3,1926
|
13
|
+
Saskatchewan,g/m3,1920
|
14
|
+
Yukon,g/m3,1966
|
File without changes
|
@@ -4,23 +4,27 @@ $OPENSTUDIO_LOG.setLogLevel(OpenStudio::Debug)
|
|
4
4
|
|
5
5
|
# Log the info, warning, and error messages to a runner.
|
6
6
|
#
|
7
|
-
#
|
8
|
-
#
|
9
|
-
# @
|
10
|
-
def log_messages_to_runner(runner, debug = false)
|
7
|
+
# @param runner [OpenStudio::Measure::OSRunner] The Measure runner to add the messages to
|
8
|
+
# @param debug [Boolean] If true, include the debug messages in the log
|
9
|
+
# @param custom_exclusions [Array<String>] An array of custom strings to exclude from the log
|
10
|
+
def log_messages_to_runner(runner, debug = false, custom_exclusions: nil)
|
11
|
+
log_message_exclusions = [
|
12
|
+
'UseWeatherFile', # 'UseWeatherFile' is not yet a supported option for YearDescription
|
13
|
+
'Skipping layer', # Annoying/bogus "Skipping layer" warnings
|
14
|
+
'runmanager', # RunManager messages
|
15
|
+
'setFileExtension', # .ddy extension unexpected
|
16
|
+
'Translator', # Forward translator and geometry translator
|
17
|
+
'Successive data points', # Successive data points (2004-Jan-31 to 2001-Feb-01, ending on line 753) are greater than 1 day apart in EPW file
|
18
|
+
'has multiple parents', # Bogus errors about curves having multiple parents
|
19
|
+
'does not have an Output', # Warning from EMS translation
|
20
|
+
'Prior to OpenStudio 2.6.2, this field was returning a double, it now returns an Optional double' # Warning about OS API change
|
21
|
+
] + Array(custom_exclusions)
|
22
|
+
|
11
23
|
$OPENSTUDIO_LOG.logMessages.each do |msg|
|
12
24
|
# DLM: you can filter on log channel here for now
|
13
25
|
if /openstudio.*/ =~ msg.logChannel # /openstudio\.model\..*/
|
14
26
|
# Skip certain messages that are irrelevant/misleading
|
15
|
-
next if msg.logMessage.include?(
|
16
|
-
msg.logMessage.include?('Skipping layer') || # Annoying/bogus "Skipping layer" warnings
|
17
|
-
msg.logChannel.include?('runmanager') || # RunManager messages
|
18
|
-
msg.logChannel.include?('setFileExtension') || # .ddy extension unexpected
|
19
|
-
msg.logChannel.include?('Translator') || # Forward translator and geometry translator
|
20
|
-
msg.logMessage.include?('Successive data points') || # Successive data points (2004-Jan-31 to 2001-Feb-01, ending on line 753) are greater than 1 day apart in EPW file
|
21
|
-
msg.logMessage.include?('has multiple parents') || # Bogus errors about curves having multiple parents
|
22
|
-
msg.logMessage.include?('does not have an Output') || # Warning from EMS translation
|
23
|
-
msg.logMessage.include?('Prior to OpenStudio 2.6.2, this field was returning a double, it now returns an Optional double') # Warning about OS API change
|
27
|
+
next if log_message_exclusions.any? { |ex| msg.logMessage.include?(ex) }
|
24
28
|
|
25
29
|
# Report the message in the correct way
|
26
30
|
if msg.logLevel == OpenStudio::Info
|
@@ -29,7 +33,7 @@ def log_messages_to_runner(runner, debug = false)
|
|
29
33
|
runner.registerWarning("[#{msg.logChannel}] #{msg.logMessage}")
|
30
34
|
elsif msg.logLevel == OpenStudio::Error
|
31
35
|
runner.registerError("[#{msg.logChannel}] #{msg.logMessage}")
|
32
|
-
elsif msg.logLevel == OpenStudio::Debug
|
36
|
+
elsif debug && msg.logLevel == OpenStudio::Debug
|
33
37
|
runner.registerInfo("DEBUG - #{msg.logMessage}")
|
34
38
|
end
|
35
39
|
end
|
@@ -181,11 +181,12 @@ Standard.class_eval do
|
|
181
181
|
#
|
182
182
|
# @param model [OpenStudio::Model::Model] OpenStudio model object
|
183
183
|
# @param sizing_run_dir [String] file path location for the sizing run, defaults to 'SR' in the current directory
|
184
|
+
# @param sizing_run_simulation [Boolean] whether to run the simulation for the sizing periods, defaults to true
|
184
185
|
# @return [Boolean] returns true if successful, false if not
|
185
|
-
def model_run_sizing_run(model, sizing_run_dir = "#{Dir.pwd}/SR")
|
186
|
+
def model_run_sizing_run(model, sizing_run_dir = "#{Dir.pwd}/SR", sizing_run_simulation = true)
|
186
187
|
# Change the simulation to only run the sizing days
|
187
188
|
sim_control = model.getSimulationControl
|
188
|
-
sim_control.setRunSimulationforSizingPeriods(
|
189
|
+
sim_control.setRunSimulationforSizingPeriods(sizing_run_simulation)
|
189
190
|
sim_control.setRunSimulationforWeatherFileRunPeriods(false)
|
190
191
|
if model.version >= OpenStudio::VersionString.new('3.0.0')
|
191
192
|
sim_control.setDoHVACSizingSimulationforSizingPeriods(true)
|
@@ -79,7 +79,7 @@ module OpenstudioStandards
|
|
79
79
|
end
|
80
80
|
|
81
81
|
# set ground temperature shallow values based on .stat file
|
82
|
-
ground_temperature_shallow =
|
82
|
+
ground_temperature_shallow = model.getSiteGroundTemperatureShallow
|
83
83
|
ground_temperature_shallow.setJanuarySurfaceGroundTemperature(stat_file.monthly_undis_ground_temps_0p5m[0])
|
84
84
|
ground_temperature_shallow.setFebruarySurfaceGroundTemperature(stat_file.monthly_undis_ground_temps_0p5m[1])
|
85
85
|
ground_temperature_shallow.setMarchSurfaceGroundTemperature(stat_file.monthly_undis_ground_temps_0p5m[2])
|
@@ -113,7 +113,7 @@ module OpenstudioStandards
|
|
113
113
|
end
|
114
114
|
|
115
115
|
# set ground temperature deep values based on .stat file
|
116
|
-
ground_temperature_deep =
|
116
|
+
ground_temperature_deep = model.getSiteGroundTemperatureDeep
|
117
117
|
ground_temperature_deep.setJanuaryDeepGroundTemperature(stat_file.monthly_undis_ground_temps_4p0m[0])
|
118
118
|
ground_temperature_deep.setFebruaryDeepGroundTemperature(stat_file.monthly_undis_ground_temps_4p0m[1])
|
119
119
|
ground_temperature_deep.setMarchDeepGroundTemperature(stat_file.monthly_undis_ground_temps_4p0m[2])
|
data/lib/openstudio-standards.rb
CHANGED
@@ -106,6 +106,17 @@ module OpenstudioStandards
|
|
106
106
|
|
107
107
|
# BTAP (Natural Resources Canada)
|
108
108
|
require_relative 'openstudio-standards/btap/btap'
|
109
|
+
require_relative 'openstudio-standards/btap/costing/btap_costing'
|
110
|
+
require_relative 'openstudio-standards/btap/costing/ventilation_costing'
|
111
|
+
require_relative 'openstudio-standards/btap/costing/envelope_costing'
|
112
|
+
require_relative 'openstudio-standards/btap/costing/lighting_costing'
|
113
|
+
require_relative 'openstudio-standards/btap/costing/heating_cooling_costing'
|
114
|
+
require_relative 'openstudio-standards/btap/costing/shw_costing'
|
115
|
+
require_relative 'openstudio-standards/btap/costing/dcv_costing'
|
116
|
+
require_relative 'openstudio-standards/btap/costing/daylighting_sensor_control_costing'
|
117
|
+
require_relative 'openstudio-standards/btap/costing/led_lighting_costing'
|
118
|
+
require_relative 'openstudio-standards/btap/costing/pv_ground_costing'
|
119
|
+
require_relative 'openstudio-standards/btap/costing/nv_costing'
|
109
120
|
|
110
121
|
# Utilities
|
111
122
|
require_relative 'openstudio-standards/utilities/logging'
|
@@ -137,6 +148,7 @@ module OpenstudioStandards
|
|
137
148
|
require_relative "#{stds}/necb/NECB2011/hvac_system_3_and_8_multi_speed"
|
138
149
|
require_relative "#{stds}/necb/NECB2011/hvac_system_4"
|
139
150
|
require_relative "#{stds}/necb/NECB2011/hvac_system_6"
|
151
|
+
require_relative "#{stds}/necb/NECB2011/hvac_namer"
|
140
152
|
require_relative "#{stds}/necb/NECB2011/service_water_heating"
|
141
153
|
require_relative "#{stds}/necb/NECB2011/electrical_power_systems_and_motors"
|
142
154
|
require_relative "#{stds}/necb/NECB2011/beps_compliance_path"
|
metadata
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
--- !ruby/object:Gem::Specification
|
2
2
|
name: openstudio-standards
|
3
3
|
version: !ruby/object:Gem::Version
|
4
|
-
version: 0.8.
|
4
|
+
version: 0.8.4
|
5
5
|
platform: ruby
|
6
6
|
authors:
|
7
7
|
- Mark Adams
|
@@ -39,7 +39,7 @@ authors:
|
|
39
39
|
autorequire:
|
40
40
|
bindir: bin
|
41
41
|
cert_chain: []
|
42
|
-
date: 2025-
|
42
|
+
date: 2025-09-26 00:00:00.000000000 Z
|
43
43
|
dependencies:
|
44
44
|
- !ruby/object:Gem::Dependency
|
45
45
|
name: bundler
|
@@ -598,9 +598,11 @@ files:
|
|
598
598
|
- data/geometry/DOERefWarehouse.json
|
599
599
|
- data/geometry/DOERefWarehouse.osm
|
600
600
|
- data/inventory/thermal_bridging.csv
|
601
|
+
- data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx
|
601
602
|
- data/standards/exclude_list.csv
|
602
603
|
- data/standards/export_OpenStudio_libraries.rb
|
603
604
|
- data/standards/manage_OpenStudio_Standards.rb
|
605
|
+
- data/standards/openstudio_standards_duplicates_log.csv
|
604
606
|
- data/standards/templates_to_climate_zones.json
|
605
607
|
- data/standards/test_performance_expected_dd_results.csv
|
606
608
|
- data/weather/ARCATA_725945_CZ2010.ddy
|
@@ -827,6 +829,49 @@ files:
|
|
827
829
|
- lib/openstudio-standards/btap/bridging.rb
|
828
830
|
- lib/openstudio-standards/btap/btap.rb
|
829
831
|
- lib/openstudio-standards/btap/btap_result.rb
|
832
|
+
- lib/openstudio-standards/btap/costing/README.md
|
833
|
+
- lib/openstudio-standards/btap/costing/btap_costing.rb
|
834
|
+
- lib/openstudio-standards/btap/costing/btap_measure_helper.rb
|
835
|
+
- lib/openstudio-standards/btap/costing/btap_workflow.rb
|
836
|
+
- lib/openstudio-standards/btap/costing/common_paths.rb
|
837
|
+
- lib/openstudio-standards/btap/costing/common_resources/ConstructionProperties.csv
|
838
|
+
- lib/openstudio-standards/btap/costing/common_resources/Constructions.csv
|
839
|
+
- lib/openstudio-standards/btap/costing/common_resources/construction_sets.csv
|
840
|
+
- lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv
|
841
|
+
- lib/openstudio-standards/btap/costing/common_resources/constructions_opaque.csv
|
842
|
+
- lib/openstudio-standards/btap/costing/common_resources/costs.csv
|
843
|
+
- lib/openstudio-standards/btap/costing/common_resources/costs_local_factors.csv
|
844
|
+
- lib/openstudio-standards/btap/costing/common_resources/hvac_vent_ahu.csv
|
845
|
+
- lib/openstudio-standards/btap/costing/common_resources/lighting.csv
|
846
|
+
- lib/openstudio-standards/btap/costing/common_resources/lighting_sets.csv
|
847
|
+
- lib/openstudio-standards/btap/costing/common_resources/locations.csv
|
848
|
+
- lib/openstudio-standards/btap/costing/common_resources/materials_glazing.csv
|
849
|
+
- lib/openstudio-standards/btap/costing/common_resources/materials_hvac.csv
|
850
|
+
- lib/openstudio-standards/btap/costing/common_resources/materials_lighting.csv
|
851
|
+
- lib/openstudio-standards/btap/costing/common_resources/materials_opaque.csv
|
852
|
+
- lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb
|
853
|
+
- lib/openstudio-standards/btap/costing/cost_building_from_file.rb
|
854
|
+
- lib/openstudio-standards/btap/costing/costing_database_wrapper.rb
|
855
|
+
- lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb
|
856
|
+
- lib/openstudio-standards/btap/costing/dcv_costing.rb
|
857
|
+
- lib/openstudio-standards/btap/costing/dummy.epw
|
858
|
+
- lib/openstudio-standards/btap/costing/dummy.osm
|
859
|
+
- lib/openstudio-standards/btap/costing/envelope_costing.rb
|
860
|
+
- lib/openstudio-standards/btap/costing/heating_cooling_costing.rb
|
861
|
+
- lib/openstudio-standards/btap/costing/led_lighting_costing.rb
|
862
|
+
- lib/openstudio-standards/btap/costing/lighting_costing.rb
|
863
|
+
- lib/openstudio-standards/btap/costing/mech_sizing.json
|
864
|
+
- lib/openstudio-standards/btap/costing/neb_end_use_prices.csv
|
865
|
+
- lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv
|
866
|
+
- lib/openstudio-standards/btap/costing/necb_reference_runs.csv
|
867
|
+
- lib/openstudio-standards/btap/costing/nv_costing.rb
|
868
|
+
- lib/openstudio-standards/btap/costing/parallel_tests.rb
|
869
|
+
- lib/openstudio-standards/btap/costing/pv_ground_costing.rb
|
870
|
+
- lib/openstudio-standards/btap/costing/shw_costing.rb
|
871
|
+
- lib/openstudio-standards/btap/costing/test_list.txt
|
872
|
+
- lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb
|
873
|
+
- lib/openstudio-standards/btap/costing/test_run_costing_tests.rb
|
874
|
+
- lib/openstudio-standards/btap/costing/ventilation_costing.rb
|
830
875
|
- lib/openstudio-standards/btap/envelope.rb
|
831
876
|
- lib/openstudio-standards/btap/fileio.rb
|
832
877
|
- lib/openstudio-standards/btap/geometry.rb
|
@@ -2287,6 +2332,7 @@ files:
|
|
2287
2332
|
- lib/openstudio-standards/standards/necb/NECB2011/data/furnaces.json
|
2288
2333
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/FullServiceRestaurant.osm
|
2289
2334
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartment.osm
|
2335
|
+
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm
|
2290
2336
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/Hospital.osm
|
2291
2337
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LEEPMidriseApartment.osm
|
2292
2338
|
- lib/openstudio-standards/standards/necb/NECB2011/data/geometry/LEEPMultiTower.osm
|
@@ -2325,10 +2371,13 @@ files:
|
|
2325
2371
|
- lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json
|
2326
2372
|
- lib/openstudio-standards/standards/necb/NECB2011/data/standards_data.rb
|
2327
2373
|
- lib/openstudio-standards/standards/necb/NECB2011/data/surface_thermal_transmittance.json
|
2374
|
+
- lib/openstudio-standards/standards/necb/NECB2011/data/systems.json
|
2375
|
+
- lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json
|
2328
2376
|
- lib/openstudio-standards/standards/necb/NECB2011/data/unitary_acs.json
|
2329
2377
|
- lib/openstudio-standards/standards/necb/NECB2011/daylighting_control.md
|
2330
2378
|
- lib/openstudio-standards/standards/necb/NECB2011/demand_controlled_ventilation.md
|
2331
2379
|
- lib/openstudio-standards/standards/necb/NECB2011/electrical_power_systems_and_motors.rb
|
2380
|
+
- lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb
|
2332
2381
|
- lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb
|
2333
2382
|
- lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb
|
2334
2383
|
- lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb
|
@@ -2395,15 +2444,19 @@ files:
|
|
2395
2444
|
- lib/openstudio-standards/standards/necb/NECB2020/data/unitary_acs.json
|
2396
2445
|
- lib/openstudio-standards/standards/necb/NECB2020/necb_2020.rb
|
2397
2446
|
- lib/openstudio-standards/standards/necb/NECB2020/service_water_heating.rb
|
2447
|
+
- lib/openstudio-standards/standards/necb/README.md
|
2398
2448
|
- lib/openstudio-standards/standards/necb/common/bc_step_code_indicators.md
|
2399
2449
|
- lib/openstudio-standards/standards/necb/common/btap_data.rb
|
2400
2450
|
- lib/openstudio-standards/standards/necb/common/btap_datapoint.rb
|
2401
2451
|
- lib/openstudio-standards/standards/necb/common/construction_defaults.osm
|
2452
|
+
- lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv
|
2402
2453
|
- lib/openstudio-standards/standards/necb/common/national_carbon_price_sched_feb_2025.json
|
2403
2454
|
- lib/openstudio-standards/standards/necb/common/neb_end_use_prices.csv
|
2404
2455
|
- lib/openstudio-standards/standards/necb/common/necb_reference_runs.csv
|
2456
|
+
- lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv
|
2405
2457
|
- lib/openstudio-standards/standards/necb/common/phius.md
|
2406
2458
|
- lib/openstudio-standards/standards/necb/common/space_type_upgrade_map.json
|
2459
|
+
- lib/openstudio-standards/standards/necb/common/system_types.yaml
|
2407
2460
|
- lib/openstudio-standards/standards/necb/common/utility_pricing_2025-02-20.csv
|
2408
2461
|
- lib/openstudio-standards/standards/necb/docs/air_system_names_method.md
|
2409
2462
|
- lib/openstudio-standards/standards/oeesc/oeesc.rb
|
@@ -2450,7 +2503,7 @@ required_rubygems_version: !ruby/object:Gem::Requirement
|
|
2450
2503
|
- !ruby/object:Gem::Version
|
2451
2504
|
version: 1.3.6
|
2452
2505
|
requirements: []
|
2453
|
-
rubygems_version: 3.
|
2506
|
+
rubygems_version: 3.5.17
|
2454
2507
|
signing_key:
|
2455
2508
|
specification_version: 4
|
2456
2509
|
summary: Creates OpenStudio models of typical buildings, creates standard baselines
|