openstudio-standards 0.8.2 → 0.8.4
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +7962 -0
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +473 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/common_paths.rb +78 -0
- data/lib/openstudio-standards/btap/costing/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/costing/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/costing/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +61 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +1904 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/costing/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/costing/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_hvac.csv +1699 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +177 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +353 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +284 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +155 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +17 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +26 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/refrigeration/create_case.rb +58 -21
- data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +4 -2
- data/lib/openstudio-standards/refrigeration/create_walkin.rb +57 -22
- data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -31
- data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -76
- data/lib/openstudio-standards/service_water_heating/create_typical.rb +10 -10
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +10 -0
- data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -3
- data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +9 -9
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +49 -49
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +159 -159
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +7 -18
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +10 -20
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -15
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +5 -6
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +93 -43
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +135 -37
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Model.rb +48 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +648 -326
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +371 -90
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +1012 -296
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +443 -79
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +672 -306
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +354 -74
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +930 -604
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +415 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +602 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +1005 -333
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +642 -88
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +78 -26
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +722 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +1741 -426
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +1108 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +186 -62
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +62 -232
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +7 -18
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +154 -69
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps_heating.json +72 -72
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +382 -295
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +6 -1
- data/lib/openstudio-standards/standards/deer/data/deer.schedules.json +62 -232
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +2 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +46 -20
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +635 -248
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +43 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +43 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +214 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +8 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +15 -6
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +20 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +10 -0
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +190 -28
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +14 -5
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/utilities/simulation.rb +3 -2
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards.rb +12 -0
- metadata +56 -3
@@ -25,7 +25,9 @@
|
|
25
25
|
"uniform_energy_factor_base": null,
|
26
26
|
"uniform_energy_factor_volume_allowance": null,
|
27
27
|
"cop": null,
|
28
|
-
"r_value": null
|
28
|
+
"r_value": null,
|
29
|
+
"first_hour_rating": null,
|
30
|
+
"solar_energy_factor": null
|
29
31
|
},
|
30
32
|
{
|
31
33
|
"equipment_type": "Table Top Water Heaters",
|
@@ -52,7 +54,9 @@
|
|
52
54
|
"uniform_energy_factor_base": null,
|
53
55
|
"uniform_energy_factor_volume_allowance": null,
|
54
56
|
"cop": null,
|
55
|
-
"r_value": null
|
57
|
+
"r_value": null,
|
58
|
+
"first_hour_rating": null,
|
59
|
+
"solar_energy_factor": null
|
56
60
|
},
|
57
61
|
{
|
58
62
|
"equipment_type": "Storage Water Heaters",
|
@@ -79,7 +83,9 @@
|
|
79
83
|
"uniform_energy_factor_base": null,
|
80
84
|
"uniform_energy_factor_volume_allowance": null,
|
81
85
|
"cop": null,
|
82
|
-
"r_value": null
|
86
|
+
"r_value": null,
|
87
|
+
"first_hour_rating": null,
|
88
|
+
"solar_energy_factor": null
|
83
89
|
},
|
84
90
|
{
|
85
91
|
"equipment_type": "Storage Water Heaters",
|
@@ -106,7 +112,9 @@
|
|
106
112
|
"uniform_energy_factor_base": null,
|
107
113
|
"uniform_energy_factor_volume_allowance": null,
|
108
114
|
"cop": null,
|
109
|
-
"r_value": null
|
115
|
+
"r_value": null,
|
116
|
+
"first_hour_rating": null,
|
117
|
+
"solar_energy_factor": null
|
110
118
|
},
|
111
119
|
{
|
112
120
|
"equipment_type": "Storage Water Heaters",
|
@@ -133,7 +141,9 @@
|
|
133
141
|
"uniform_energy_factor_base": null,
|
134
142
|
"uniform_energy_factor_volume_allowance": null,
|
135
143
|
"cop": null,
|
136
|
-
"r_value": null
|
144
|
+
"r_value": null,
|
145
|
+
"first_hour_rating": null,
|
146
|
+
"solar_energy_factor": null
|
137
147
|
},
|
138
148
|
{
|
139
149
|
"equipment_type": "Storage Water Heaters",
|
@@ -160,7 +170,9 @@
|
|
160
170
|
"uniform_energy_factor_base": null,
|
161
171
|
"uniform_energy_factor_volume_allowance": null,
|
162
172
|
"cop": null,
|
163
|
-
"r_value": null
|
173
|
+
"r_value": null,
|
174
|
+
"first_hour_rating": null,
|
175
|
+
"solar_energy_factor": null
|
164
176
|
},
|
165
177
|
{
|
166
178
|
"equipment_type": "Storage Water Heaters",
|
@@ -187,7 +199,9 @@
|
|
187
199
|
"uniform_energy_factor_base": null,
|
188
200
|
"uniform_energy_factor_volume_allowance": null,
|
189
201
|
"cop": null,
|
190
|
-
"r_value": null
|
202
|
+
"r_value": null,
|
203
|
+
"first_hour_rating": null,
|
204
|
+
"solar_energy_factor": null
|
191
205
|
},
|
192
206
|
{
|
193
207
|
"equipment_type": "Storage Water Heaters",
|
@@ -214,7 +228,9 @@
|
|
214
228
|
"uniform_energy_factor_base": null,
|
215
229
|
"uniform_energy_factor_volume_allowance": null,
|
216
230
|
"cop": null,
|
217
|
-
"r_value": null
|
231
|
+
"r_value": null,
|
232
|
+
"first_hour_rating": null,
|
233
|
+
"solar_energy_factor": null
|
218
234
|
},
|
219
235
|
{
|
220
236
|
"equipment_type": "Instantaneous Water Heaters",
|
@@ -241,7 +257,9 @@
|
|
241
257
|
"uniform_energy_factor_base": null,
|
242
258
|
"uniform_energy_factor_volume_allowance": null,
|
243
259
|
"cop": null,
|
244
|
-
"r_value": null
|
260
|
+
"r_value": null,
|
261
|
+
"first_hour_rating": null,
|
262
|
+
"solar_energy_factor": null
|
245
263
|
},
|
246
264
|
{
|
247
265
|
"equipment_type": "Instantaneous Water Heaters",
|
@@ -268,7 +286,9 @@
|
|
268
286
|
"uniform_energy_factor_base": null,
|
269
287
|
"uniform_energy_factor_volume_allowance": null,
|
270
288
|
"cop": null,
|
271
|
-
"r_value": null
|
289
|
+
"r_value": null,
|
290
|
+
"first_hour_rating": null,
|
291
|
+
"solar_energy_factor": null
|
272
292
|
},
|
273
293
|
{
|
274
294
|
"equipment_type": "Instantaneous Water Heaters",
|
@@ -295,7 +315,9 @@
|
|
295
315
|
"uniform_energy_factor_base": null,
|
296
316
|
"uniform_energy_factor_volume_allowance": null,
|
297
317
|
"cop": null,
|
298
|
-
"r_value": null
|
318
|
+
"r_value": null,
|
319
|
+
"first_hour_rating": null,
|
320
|
+
"solar_energy_factor": null
|
299
321
|
},
|
300
322
|
{
|
301
323
|
"equipment_type": "Storage Water Heaters",
|
@@ -322,7 +344,9 @@
|
|
322
344
|
"uniform_energy_factor_base": null,
|
323
345
|
"uniform_energy_factor_volume_allowance": null,
|
324
346
|
"cop": null,
|
325
|
-
"r_value": null
|
347
|
+
"r_value": null,
|
348
|
+
"first_hour_rating": null,
|
349
|
+
"solar_energy_factor": null
|
326
350
|
},
|
327
351
|
{
|
328
352
|
"equipment_type": "Storage Water Heaters",
|
@@ -349,7 +373,9 @@
|
|
349
373
|
"uniform_energy_factor_base": null,
|
350
374
|
"uniform_energy_factor_volume_allowance": null,
|
351
375
|
"cop": null,
|
352
|
-
"r_value": null
|
376
|
+
"r_value": null,
|
377
|
+
"first_hour_rating": null,
|
378
|
+
"solar_energy_factor": null
|
353
379
|
},
|
354
380
|
{
|
355
381
|
"equipment_type": "Instantaneous Water Heaters",
|
@@ -376,7 +402,9 @@
|
|
376
402
|
"uniform_energy_factor_base": null,
|
377
403
|
"uniform_energy_factor_volume_allowance": null,
|
378
404
|
"cop": null,
|
379
|
-
"r_value": null
|
405
|
+
"r_value": null,
|
406
|
+
"first_hour_rating": null,
|
407
|
+
"solar_energy_factor": null
|
380
408
|
},
|
381
409
|
{
|
382
410
|
"equipment_type": "Instantaneous Water Heaters",
|
@@ -403,7 +431,9 @@
|
|
403
431
|
"uniform_energy_factor_base": null,
|
404
432
|
"uniform_energy_factor_volume_allowance": null,
|
405
433
|
"cop": null,
|
406
|
-
"r_value": null
|
434
|
+
"r_value": null,
|
435
|
+
"first_hour_rating": null,
|
436
|
+
"solar_energy_factor": null
|
407
437
|
},
|
408
438
|
{
|
409
439
|
"equipment_type": "Instantaneous Water Heaters",
|
@@ -430,7 +460,9 @@
|
|
430
460
|
"uniform_energy_factor_base": null,
|
431
461
|
"uniform_energy_factor_volume_allowance": null,
|
432
462
|
"cop": null,
|
433
|
-
"r_value": null
|
463
|
+
"r_value": null,
|
464
|
+
"first_hour_rating": null,
|
465
|
+
"solar_energy_factor": null
|
434
466
|
},
|
435
467
|
{
|
436
468
|
"equipment_type": "Hot Water Supply Boiler",
|
@@ -457,7 +489,9 @@
|
|
457
489
|
"uniform_energy_factor_base": null,
|
458
490
|
"uniform_energy_factor_volume_allowance": null,
|
459
491
|
"cop": null,
|
460
|
-
"r_value": null
|
492
|
+
"r_value": null,
|
493
|
+
"first_hour_rating": null,
|
494
|
+
"solar_energy_factor": null
|
461
495
|
},
|
462
496
|
{
|
463
497
|
"equipment_type": "Hot Water Supply Boiler",
|
@@ -484,7 +518,9 @@
|
|
484
518
|
"uniform_energy_factor_base": null,
|
485
519
|
"uniform_energy_factor_volume_allowance": null,
|
486
520
|
"cop": null,
|
487
|
-
"r_value": null
|
521
|
+
"r_value": null,
|
522
|
+
"first_hour_rating": null,
|
523
|
+
"solar_energy_factor": null
|
488
524
|
},
|
489
525
|
{
|
490
526
|
"equipment_type": "Hot Water Supply Boiler",
|
@@ -511,7 +547,9 @@
|
|
511
547
|
"uniform_energy_factor_base": null,
|
512
548
|
"uniform_energy_factor_volume_allowance": null,
|
513
549
|
"cop": null,
|
514
|
-
"r_value": null
|
550
|
+
"r_value": null,
|
551
|
+
"first_hour_rating": null,
|
552
|
+
"solar_energy_factor": null
|
515
553
|
},
|
516
554
|
{
|
517
555
|
"equipment_type": "Hot Water Supply Boiler",
|
@@ -538,7 +576,9 @@
|
|
538
576
|
"uniform_energy_factor_base": null,
|
539
577
|
"uniform_energy_factor_volume_allowance": null,
|
540
578
|
"cop": null,
|
541
|
-
"r_value": null
|
579
|
+
"r_value": null,
|
580
|
+
"first_hour_rating": null,
|
581
|
+
"solar_energy_factor": null
|
542
582
|
},
|
543
583
|
{
|
544
584
|
"equipment_type": "Pool Heater",
|
@@ -565,7 +605,9 @@
|
|
565
605
|
"uniform_energy_factor_base": null,
|
566
606
|
"uniform_energy_factor_volume_allowance": null,
|
567
607
|
"cop": null,
|
568
|
-
"r_value": null
|
608
|
+
"r_value": null,
|
609
|
+
"first_hour_rating": null,
|
610
|
+
"solar_energy_factor": null
|
569
611
|
},
|
570
612
|
{
|
571
613
|
"equipment_type": "Pool Heater",
|
@@ -592,7 +634,9 @@
|
|
592
634
|
"uniform_energy_factor_base": null,
|
593
635
|
"uniform_energy_factor_volume_allowance": null,
|
594
636
|
"cop": null,
|
595
|
-
"r_value": null
|
637
|
+
"r_value": null,
|
638
|
+
"first_hour_rating": null,
|
639
|
+
"solar_energy_factor": null
|
596
640
|
},
|
597
641
|
{
|
598
642
|
"equipment_type": "Heat Pump Pool Heater",
|
@@ -619,7 +663,9 @@
|
|
619
663
|
"uniform_energy_factor_base": null,
|
620
664
|
"uniform_energy_factor_volume_allowance": null,
|
621
665
|
"cop": 4,
|
622
|
-
"r_value": null
|
666
|
+
"r_value": null,
|
667
|
+
"first_hour_rating": null,
|
668
|
+
"solar_energy_factor": null
|
623
669
|
},
|
624
670
|
{
|
625
671
|
"equipment_type": "Unfired Storage Tank",
|
@@ -646,7 +692,9 @@
|
|
646
692
|
"uniform_energy_factor_base": null,
|
647
693
|
"uniform_energy_factor_volume_allowance": null,
|
648
694
|
"cop": null,
|
649
|
-
"r_value": 12.5
|
695
|
+
"r_value": 12.5,
|
696
|
+
"first_hour_rating": null,
|
697
|
+
"solar_energy_factor": null
|
650
698
|
}
|
651
699
|
]
|
652
700
|
}
|