openstudio-standards 0.8.2 → 0.8.4
This diff represents the content of publicly available package versions that have been released to one of the supported registries. The information contained in this diff is provided for informational purposes only and reflects changes between package versions as they appear in their respective public registries.
- checksums.yaml +4 -4
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/openstudio_standards_duplicates_log.csv +7962 -0
- data/lib/openstudio-standards/btap/costing/README.md +502 -0
- data/lib/openstudio-standards/btap/costing/btap_costing.rb +473 -0
- data/lib/openstudio-standards/btap/costing/btap_measure_helper.rb +359 -0
- data/lib/openstudio-standards/btap/costing/btap_workflow.rb +117 -0
- data/lib/openstudio-standards/btap/costing/common_paths.rb +78 -0
- data/lib/openstudio-standards/btap/costing/common_resources/ConstructionProperties.csv +52 -0
- data/lib/openstudio-standards/btap/costing/common_resources/Constructions.csv +37 -0
- data/lib/openstudio-standards/btap/costing/common_resources/construction_sets.csv +1270 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_glazing.csv +61 -0
- data/lib/openstudio-standards/btap/costing/common_resources/constructions_opaque.csv +2256 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs.csv +1904 -0
- data/lib/openstudio-standards/btap/costing/common_resources/costs_local_factors.csv +2315 -0
- data/lib/openstudio-standards/btap/costing/common_resources/hvac_vent_ahu.csv +925 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting.csv +364 -0
- data/lib/openstudio-standards/btap/costing/common_resources/lighting_sets.csv +2667 -0
- data/lib/openstudio-standards/btap/costing/common_resources/locations.csv +75 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_glazing.csv +35 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_hvac.csv +1699 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_lighting.csv +267 -0
- data/lib/openstudio-standards/btap/costing/common_resources/materials_opaque.csv +164 -0
- data/lib/openstudio-standards/btap/costing/copy_test_results_files_to_expected_results.rb +11 -0
- data/lib/openstudio-standards/btap/costing/cost_building_from_file.rb +136 -0
- data/lib/openstudio-standards/btap/costing/costing_database_wrapper.rb +177 -0
- data/lib/openstudio-standards/btap/costing/daylighting_sensor_control_costing.rb +353 -0
- data/lib/openstudio-standards/btap/costing/dcv_costing.rb +314 -0
- data/lib/openstudio-standards/btap/costing/dummy.epw +8768 -0
- data/lib/openstudio-standards/btap/costing/dummy.osm +5320 -0
- data/lib/openstudio-standards/btap/costing/envelope_costing.rb +284 -0
- data/lib/openstudio-standards/btap/costing/heating_cooling_costing.rb +2584 -0
- data/lib/openstudio-standards/btap/costing/led_lighting_costing.rb +155 -0
- data/lib/openstudio-standards/btap/costing/lighting_costing.rb +209 -0
- data/lib/openstudio-standards/btap/costing/mech_sizing.json +502 -0
- data/lib/openstudio-standards/btap/costing/neb_end_use_prices.csv +42 -0
- data/lib/openstudio-standards/btap/costing/necb_2011_spacetype_info.csv +225 -0
- data/lib/openstudio-standards/btap/costing/necb_reference_runs.csv +28705 -0
- data/lib/openstudio-standards/btap/costing/nv_costing.rb +547 -0
- data/lib/openstudio-standards/btap/costing/parallel_tests.rb +92 -0
- data/lib/openstudio-standards/btap/costing/pv_ground_costing.rb +687 -0
- data/lib/openstudio-standards/btap/costing/shw_costing.rb +705 -0
- data/lib/openstudio-standards/btap/costing/test_list.txt +17 -0
- data/lib/openstudio-standards/btap/costing/test_run_all_test_locally.rb +26 -0
- data/lib/openstudio-standards/btap/costing/test_run_costing_tests.rb +80 -0
- data/lib/openstudio-standards/btap/costing/ventilation_costing.rb +2616 -0
- data/lib/openstudio-standards/constructions/modify.rb +2 -1
- data/lib/openstudio-standards/refrigeration/create_case.rb +58 -21
- data/lib/openstudio-standards/refrigeration/create_typical_refrigeration.rb +4 -2
- data/lib/openstudio-standards/refrigeration/create_walkin.rb +57 -22
- data/lib/openstudio-standards/refrigeration/data/refrigerated_cases.csv +31 -31
- data/lib/openstudio-standards/refrigeration/data/refrigerated_walkins.csv +76 -76
- data/lib/openstudio-standards/service_water_heating/create_typical.rb +10 -10
- data/lib/openstudio-standards/service_water_heating/create_water_heater.rb +10 -0
- data/lib/openstudio-standards/service_water_heating/create_water_heating_loop.rb +16 -3
- data/lib/openstudio-standards/service_water_heating/data/convert_data.rb +9 -9
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.csv +49 -49
- data/lib/openstudio-standards/service_water_heating/data/typical_water_use_equipment.json +159 -159
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXMultiSpeed.rb +7 -18
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +10 -20
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +6 -15
- data/lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb +5 -6
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +93 -43
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXMultiSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilHeatingDXSingleSpeed.rb +135 -37
- data/lib/openstudio-standards/standards/Standards.CoilHeatingWaterToAirHeatPumpEquationFit.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Model.rb +48 -13
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps.json +648 -326
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.heat_pumps_heating.json +371 -90
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps.json +1012 -296
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.heat_pumps_heating.json +443 -79
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.water_heaters.json +66 -22
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps.json +672 -306
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.heat_pumps_heating.json +354 -74
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.computer_room_acs.json +302 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.energy_recovery.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps.json +930 -604
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.heat_pumps_heating.json +415 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.water_heaters.json +72 -24
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.computer_room_acs.json +602 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps.json +1005 -333
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.heat_pumps_heating.json +642 -88
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2016/data/ashrae_90_1_2016.water_heaters.json +78 -26
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.computer_room_acs.json +722 -140
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps.json +1741 -426
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.heat_pumps_heating.json +1108 -111
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2019/data/ashrae_90_1_2019.water_heaters.json +186 -62
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +62 -232
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXSingleSpeed.rb +2 -3
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilCoolingDXTwoSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilDX.rb +7 -18
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingDXSingleSpeed.rb +9 -7
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.CoilHeatingGas.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm.Model.rb +2 -2
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps.json +154 -69
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.heat_pumps_heating.json +72 -72
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/ashrae_90_1_prm_2019/data/ashrae_90_1_prm_2019.water_heaters.json +382 -295
- data/lib/openstudio-standards/standards/ashrae_90_1_prm/userdata_csv/ashrae_90_1_prm.UserData.rb +6 -1
- data/lib/openstudio-standards/standards/deer/data/deer.schedules.json +62 -232
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/btap_pre1980.rb +2 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_3_and_8_single_speed.rb +68 -27
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_4.rb +64 -25
- data/lib/openstudio-standards/standards/necb/BTAPPRE1980/hvac_system_6.rb +9 -14
- data/lib/openstudio-standards/standards/necb/ECMS/hvac_systems.rb +46 -20
- data/lib/openstudio-standards/standards/necb/NECB2011/autozone.rb +635 -248
- data/lib/openstudio-standards/standards/necb/NECB2011/data/constants.json +43 -7
- data/lib/openstudio-standards/standards/necb/NECB2011/data/fuel_type_sets.json +7 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/geometry/HighriseApartmentMult.osm +14272 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/heat_pumps_heating.json +6 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/necb_2015_table_c1.json +1 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/data/space_types.json +437 -437
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems.json +516 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/data/systems_including_sys5.json +588 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_namer.rb +489 -0
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_single_speed.rb +16 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_2_and_5.rb +48 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +2 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_single_speed.rb +35 -27
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_4.rb +34 -23
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +8 -6
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +43 -14
- data/lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb +214 -25
- data/lib/openstudio-standards/standards/necb/NECB2011/system_fuels.rb +61 -1
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps.json +16 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/heat_pumps_heating.json +8 -0
- data/lib/openstudio-standards/standards/necb/NECB2015/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2015/data/unitary_acs.json +38 -38
- data/lib/openstudio-standards/standards/necb/NECB2015/hvac_systems.rb +15 -6
- data/lib/openstudio-standards/standards/necb/NECB2017/data/space_types.json +636 -636
- data/lib/openstudio-standards/standards/necb/NECB2020/data/chillers.json +71 -71
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps.json +20 -0
- data/lib/openstudio-standards/standards/necb/NECB2020/data/heat_pumps_heating.json +10 -0
- data/lib/openstudio-standards/standards/necb/README.md +343 -0
- data/lib/openstudio-standards/standards/necb/common/btap_data.rb +190 -28
- data/lib/openstudio-standards/standards/necb/common/btap_datapoint.rb +14 -5
- data/lib/openstudio-standards/standards/necb/common/eccc_electric_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/nir_gas_grid_intensity_20250311.csv +14 -0
- data/lib/openstudio-standards/standards/necb/common/system_types.yaml +0 -0
- data/lib/openstudio-standards/utilities/logging.rb +18 -14
- data/lib/openstudio-standards/utilities/simulation.rb +3 -2
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/modify.rb +2 -2
- data/lib/openstudio-standards.rb +12 -0
- metadata +56 -3
@@ -0,0 +1,364 @@
|
|
1
|
+
lighting_type_id,description,source,type,id,id_layers,unit,Id_layers_quantity_multipliers,material_descriptions,W/m2,Fix_1000ft
|
2
|
+
1,"Fluorescent Lighting 0.8 W/ft2 (8.6 W/m2), 20FC, 5 Fixtures/1000 Ft2",rs-means,Assembly,291904,"11,13,14,15,26",ft2,"0.003,0.128,0.005,0.005,0.005","Wire 600V #12 in raceway
|
3
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
4
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
5
|
+
Steel Outlet boxes, on framing
|
6
|
+
Recessed Ceiling Mount Fixtures: grid suspension, 2x4 fixtures, T8, 32 watt lamps, acrylic prismatic diffusers
|
7
|
+
",8.6,5
|
8
|
+
2,"Fluorescent Lighting 1.6 W/ft2 (17.2 W/m2), 40FC, 10 Fixtures per 1000 ft2",rs-means,Assembly,291905,"11,13,14,15,26",ft2,"0.005,0.256,0.01,0.01,0.01","Wire 600V #12 in raceway
|
9
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
10
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
11
|
+
Steel Outlet boxes, on framing
|
12
|
+
Recessed Ceiling Mount Fixtures: grid suspension, 2x4 fixtures, T8, 32 watt lamps, acrylic prismatic diffusers
|
13
|
+
",17.2,10
|
14
|
+
3,"Fluorescent Lighting 2.4 W/ft2 (25.8 W/m2), 60FC, 15 Fixtures per 1000 ft2",rs-means,Assembly,291906,"11,13,14,15,26",ft2,"0.008,0.384,0.015,0.015,0.015","Wire 600V #12 in raceway
|
15
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
16
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
17
|
+
Steel Outlet boxes, on framing
|
18
|
+
Recessed Ceiling Mount Fixtures: grid suspension, 2x4 fixtures, T8, 32 watt lamps, acrylic prismatic diffusers
|
19
|
+
",25.8,15
|
20
|
+
4,"Fluorescent Lighting 3.2 W/ft2 (34.4 W/m2), 80FC, 20 Fixtures per 1000 ft2",rs-means,Assembly,291907,"11,13,14,15,26",ft2,"0.01,0.512,0.02,0.02,0.02","Wire 600V #12 in raceway
|
21
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
22
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
23
|
+
Steel Outlet boxes, on framing
|
24
|
+
Recessed Ceiling Mount Fixtures: grid suspension, 2x4 fixtures, T8, 32 watt lamps, acrylic prismatic diffusers
|
25
|
+
",34.4,20
|
26
|
+
5,"Fluorescent Lighting 4 W/ft2 (43 W/m2), 100FC, 25 Fixtures per 1000 ft2",rs-means,Assembly,291908,"11,13,14,15,26",ft2,"0.013,0.64,0.025,0.025,0.025","Wire 600V #12 in raceway
|
27
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
28
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
29
|
+
Steel Outlet boxes, on framing
|
30
|
+
Recessed Ceiling Mount Fixtures: grid suspension, 2x4 fixtures, T8, 32 watt lamps, acrylic prismatic diffusers
|
31
|
+
",43,25
|
32
|
+
6,"High Bay (10 ft above work plane) Fluorescent Lighting .5 W/ft2 (5.4 W/m2), 29FC, 2 Fixtures per 1000 ft2",rs-means,Assembly,291909,"12,13,14,15,27",ft2,"0.002,0.1,0.002,0.002,0.002","Wire 600V #10 in raceway
|
33
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
34
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
35
|
+
Steel Outlet boxes, on framing
|
36
|
+
Pendant Mount, 4-54W T5HO 16"" x 4' fixtures, includes hardware
|
37
|
+
",5.4,2
|
38
|
+
7,"High Bay (10 ft above work plane) Fluorescent Lighting 1.5 W/ft2 (16 W/m2), 103FC, 7 Fixtures per 1000 ft2",rs-means,Assembly,291910,"12,13,14,15,27",ft2,"0.006,0.27,0.007,0.007,0.007","Wire 600V #10 in raceway
|
39
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
40
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
41
|
+
Steel Outlet boxes, on framing
|
42
|
+
Pendant Mount, 4-54W T5HO 16"" x 4' fixtures, includes hardware
|
43
|
+
",16,7
|
44
|
+
8,"High Bay (10 ft above work plane) Fluorescent Lighting 2.5 W/ft2 (27 W/m2), 162FC, 11 Fixtures per 1000 ft2",rs-means,Assembly,291911,"12,13,14,15,27","0.006,0.27,0.007,0.007,0.007","0.009,0.465,0.011,0.011,0.011","Wire 600V #10 in raceway
|
45
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
46
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
47
|
+
Steel Outlet boxes, on framing
|
48
|
+
Pendant Mount, 4-54W T5HO 16"" x 4' fixtures, includes hardware
|
49
|
+
",27,11
|
50
|
+
9,"H.I.D. High Bay (16 ft above work plane) 1 W/ft2 (10.8 W/m2), 52FC, 1 Fixtures per 1000 ft2",rs-means,Assembly,291912,"12,13,14,15,60",ft2,"0.003,0.16,0.001,0.001,0.001","Wire 600V #10 in raceway
|
51
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
52
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
53
|
+
Steel Outlet boxes, on framing
|
54
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
55
|
+
",10.8,1
|
56
|
+
10,"H.I.D. High Bay (16 ft above work plane) 2 W/ft2 (21.5 W/m2), 105FC, 2 Fixtures per 1000 ft2",rs-means,Assembly,291913,"12,13,14,15,60",ft2,"0.007,0.32,0.002,0.002,0.002","Wire 600V #10 in raceway
|
57
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
58
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
59
|
+
Steel Outlet boxes, on framing
|
60
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
61
|
+
",21.5,2
|
62
|
+
11,"H.I.D. High Bay (16 ft above work plane) 4 W/ft2 (43 W/m2), 210FC, 4 Fixtures per 1000 ft2",rs-means,Assembly,291914,"12,13,14,15,60",ft2,"0.014,0.64,0.004,0.004,0.004","Wire 600V #10 in raceway
|
63
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
64
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
65
|
+
Steel Outlet boxes, on framing
|
66
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
67
|
+
",43,4
|
68
|
+
12,"H.I.D. High Bay (16 ft above work plane) 5 W/ft2 (54 W/m2), 262FC, 5Fixtures per 1000 ft2",rs-means,Assembly,291915,"12,13,14,15,60",ft2,"0.017,0.8,0.005,0.005,0.005","Wire 600V #10 in raceway
|
69
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
70
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
71
|
+
Steel Outlet boxes, on framing
|
72
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
73
|
+
",54,5
|
74
|
+
13,"H.I.D. High Bay (20 ft above work plane) 1 W/ft2 (10.8 W/m2), 50FC, 1 Fixtures per 1000 ft2",rs-means,Assembly,291916,"12,13,14,15,60",ft2,"0.005,0.16,0.001,0.001,0.001","Wire 600V #10 in raceway
|
75
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
76
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
77
|
+
Steel Outlet boxes, on framing
|
78
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
79
|
+
",10.8,1
|
80
|
+
14,"H.I.D. High Bay (20 ft above work plane) 2 W/ft2 (21.5 W/m2), 101FC, 2 Fixtures per 1000 ft2",rs-means,Assembly,291917,"12,13,14,15,60",ft2,"0.01,0.32,0.002,0.002,0.002","Wire 600V #10 in raceway
|
81
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
82
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
83
|
+
Steel Outlet boxes, on framing
|
84
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
85
|
+
",21.5,2
|
86
|
+
15,"H.I.D. High Bay (20 ft above work plane) 4 W/ft2 (43 W/m2), 202FC, 4 Fixtures per 1000 ft2",rs-means,Assembly,291918,"12,13,14,15,60",ft2,"0.02,0.64,0.004,0.004,0.004","Wire 600V #10 in raceway
|
87
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
88
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
89
|
+
Steel Outlet boxes, on framing
|
90
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
91
|
+
",43,4
|
92
|
+
16,"H.I.D. High Bay (20 ft above work plane) 5 W/ft2 (54 W/m2), 252FC, 5 Fixtures per 1000 ft2",rs-means,Assembly,291919,"12,13,14,15,60",ft2,"0.025,0.8,0.005,0.005,0.005","Wire 600V #10 in raceway
|
93
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
94
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
95
|
+
Steel Outlet boxes, on framing
|
96
|
+
Metal Halide 1000 W bulb Surface Mount, aluminum reflector, includes hardware
|
97
|
+
",54,5
|
98
|
+
17,"H.I.D. Low Bay (16 ft above work plane) 1 W/ft2 (10.8 W/m2), 28FC, 4 Fixtures per 1000 ft2",rs-means,Assembly,291920,"12,13,14,15,61",ft2,"0.01,0.328,0.004,0.004,0.004","Wire 600V #10 in raceway
|
99
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
100
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
101
|
+
Steel Outlet boxes, on framing
|
102
|
+
Metal Halide 250W lamps Type J Low Bay Surface Mount, aluminum reflector 28FC, includes hardware
|
103
|
+
",10.8,4
|
104
|
+
18,"H.I.D. Low Bay (16 ft above work plane) 2 W/ft2 (21.5 W/m2), 48FC, 7 Fixtures per 1000 ft2",rs-means,Assembly,291921,"12,13,14,15,61",ft2,"0.02,0.656,0.007,0.007,0.007","Wire 600V #10 in raceway
|
105
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
106
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
107
|
+
Steel Outlet boxes, on framing
|
108
|
+
Metal Halide 250W lamps Type J Low Bay Surface Mount, aluminum reflector 28FC, includes hardware
|
109
|
+
",21.5,7
|
110
|
+
19,"H.I.D. Low Bay (16 ft above work plane) 4 W/ft2 (43 W/m2), 95FC, 14 Fixtures per 1000 ft2",rs-means,Assembly,291922,"12,13,14,15,61",ft2,"0.04,1.312,0.014,0.014,0.014","Wire 600V #10 in raceway
|
111
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
112
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
113
|
+
Steel Outlet boxes, on framing
|
114
|
+
Metal Halide 250W lamps Type J Low Bay Surface Mount, aluminum reflector 28FC, includes hardware
|
115
|
+
",43,14
|
116
|
+
20,"H.I.D. Low Bay (16 ft above work plane) 5 W/ft2 (54 W/m2), 122FC, 18 Fixtures per 1000 ft2",rs-means,Assembly,291923,"12,13,14,15,61",ft2,"0.05,1.64,0.018,0.018,0.018","Wire 600V #10 in raceway
|
117
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
118
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
119
|
+
Steel Outlet boxes, on framing
|
120
|
+
Metal Halide 250W lamps Type J Low Bay Surface Mount, aluminum reflector 28FC, includes hardware
|
121
|
+
",54,18
|
122
|
+
21,"LED Lighting 23 W 2 x4 troffer recess mounted 400 Lux, 12 Fixtures/1000 Ft2 for max. 8 ft ceiling",rs-means,Assembly,291904,"10,13,14,15,104",ft2,"0.003,0.128,0.012,0.012,0.012","Wire 600V #14 Stranded THWN-THHN
|
123
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
124
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
125
|
+
Steel Outlet boxes, on framing
|
126
|
+
Interior LED fixtures, troffer, recess mounted, 37 Watts, 3200 Lumens, 2' x 4', incl lamps, mounting hardware and connections, replaces 2 T8s
|
127
|
+
",3,12
|
128
|
+
22,"LED Lighting 23 W 2 x4 troffer recess mounted 188 Lux, 6 Fixtures/1000 Ft2 for max. 8 foot ceilings",rs-means,Assembly,291904,"10,13,14,15,104",ft2,"0.003,0.128,0.006,0.006,0.006","Wire 600V #14 Stranded THWN-THHN
|
129
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
130
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
131
|
+
Steel Outlet boxes, on framing
|
132
|
+
Interior LED fixtures, troffer, recess mounted, 37 Watts, 3200 Lumens, 2' x 4', incl lamps, mounting hardware and connections, replaces 2 T8s
|
133
|
+
",1.6,6
|
134
|
+
23,"LED Lighting 23 W 2 x4 troffer recess mounted 400 Lux, 20 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,104",ft2,"0.003,0.128,0.02,0.02,0.02","Wire 600V #14 Stranded THWN-THHN
|
135
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
136
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
137
|
+
Steel Outlet boxes, on framing
|
138
|
+
Interior LED fixtures, troffer, recess mounted, 37 Watts, 3200 Lumens, 2' x 4', incl lamps, mounting hardware and connections, replaces 2 T8s
|
139
|
+
",5,20
|
140
|
+
24,"LED Lighting 23 W 2 x4 troffer recess mounted 200 Lux, 9 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,104",ft2,"0.003,0.128,0.009,0.009,0.009","Wire 600V #14 Stranded THWN-THHN
|
141
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
142
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
143
|
+
Steel Outlet boxes, on framing
|
144
|
+
Interior LED fixtures, troffer, recess mounted, 37 Watts, 3200 Lumens, 2' x 4', incl lamps, mounting hardware and connections, replaces 2 T8s
|
145
|
+
",2.26,9
|
146
|
+
25,"LED Lighting 23 W 2 x4 troffer recess mounted 500 Lux, 16 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,104",ft2,"0.003,0.128,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
147
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
148
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
149
|
+
Steel Outlet boxes, on framing
|
150
|
+
Interior LED fixtures, troffer, recess mounted, 37 Watts, 3200 Lumens, 2' x 4', incl lamps, mounting hardware and connections, replaces 2 T8s
|
151
|
+
",4,16
|
152
|
+
26,"LED Lighting 23 W 2 x4 troffer recess mounted 600 Lux, 20 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,104",ft2,"0.003,0.128,0.02,0.02,0.02","Wire 600V #14 Stranded THWN-THHN
|
153
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
154
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
155
|
+
Steel Outlet boxes, on framing
|
156
|
+
Interior LED fixtures, troffer, recess mounted, 37 Watts, 3200 Lumens, 2' x 4', incl lamps, mounting hardware and connections, replaces 2 T8s
|
157
|
+
",5,20
|
158
|
+
27,"LED Lighting 23 W 2 x4 troffer recess mounted 1000 Lux, 36 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,104",ft2,"0.003,0.128,0.036,0.036,0.036","Wire 600V #14 Stranded THWN-THHN
|
159
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
160
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
161
|
+
Steel Outlet boxes, on framing
|
162
|
+
Interior LED fixtures, troffer, recess mounted, 37 Watts, 3200 Lumens, 2' x 4', incl lamps, mounting hardware and connections, replaces 2 T8s
|
163
|
+
",9,36
|
164
|
+
28,"LED Lighting 22 W strip LED suspended 350 Lux, 16 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,111",ft2,"0.003,0.128,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
165
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
166
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
167
|
+
Steel Outlet boxes, on framing
|
168
|
+
Interior LED fixtures, strip, surface mounted, 37 Watts, 3500K, one light bar 4' long, incl lamps, mounting hardware and connections
|
169
|
+
",4,16
|
170
|
+
29,"LED Lighting 22 W strip LED suspended 150 Lux, 6 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,111",ft2,"0.003,0.128,0.006,0.006,0.006","Wire 600V #14 Stranded THWN-THHN
|
171
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
172
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
173
|
+
Steel Outlet boxes, on framing
|
174
|
+
Interior LED fixtures, strip, surface mounted, 37 Watts, 3500K, one light bar 4' long, incl lamps, mounting hardware and connections
|
175
|
+
",2.5,6
|
176
|
+
30,"LED Lighting 25 W LED suspended 300 Lux, 12 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.012,0.012,0.012","Wire 600V #14 Stranded THWN-THHN
|
177
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
178
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
179
|
+
Steel Outlet boxes, on framing
|
180
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
181
|
+
",3.3,12
|
182
|
+
31,"LED Lighting 25 W LED suspended 400 Lux, 16 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
183
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
184
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
185
|
+
Steel Outlet boxes, on framing
|
186
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
187
|
+
",4.3,16
|
188
|
+
32,"LED Lighting 25 W LED suspended 500 Lux, 20 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.02,0.02,0.02","Wire 600V #14 Stranded THWN-THHN
|
189
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
190
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
191
|
+
Steel Outlet boxes, on framing
|
192
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
193
|
+
",5.2,20
|
194
|
+
33,"LED Lighting 25 W LED suspended 600 Lux, 25 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.025,0.025,0.025","Wire 600V #14 Stranded THWN-THHN
|
195
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
196
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
197
|
+
Steel Outlet boxes, on framing
|
198
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
199
|
+
",6.5,25
|
200
|
+
34,"LED Lighting 25 W LED suspended 800 Lux, 36 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.036,0.036,0.036","Wire 600V #14 Stranded THWN-THHN
|
201
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
202
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
203
|
+
Steel Outlet boxes, on framing
|
204
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
205
|
+
",11.8,36
|
206
|
+
35,"LED Lighting 25 W LED suspended 1000 Lux, 42 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.042,0.042,0.042","Wire 600V #14 Stranded THWN-THHN
|
207
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
208
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
209
|
+
Steel Outlet boxes, on framing
|
210
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
211
|
+
",14.8,42
|
212
|
+
36,"LED Lighting 25 W LED suspended 1600 Lux, 64 Fixtures/1000 Ft2 for max. 8 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.064,0.064,0.064","Wire 600V #14 Stranded THWN-THHN
|
213
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
214
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
215
|
+
Steel Outlet boxes, on framing
|
216
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
217
|
+
",17.4,64
|
218
|
+
37,"LED Lighting 25 W LED suspended 300 Lux, 16 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
219
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
220
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
221
|
+
Steel Outlet boxes, on framing
|
222
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
223
|
+
",4.8,16
|
224
|
+
38,"LED Lighting 25 W LED suspended 150 Lux, 9 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.009,0.009,0.009","Wire 600V #14 Stranded THWN-THHN
|
225
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
226
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
227
|
+
Steel Outlet boxes, on framing
|
228
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
229
|
+
",2.7,9
|
230
|
+
39,"LED Lighting 25 W LED suspended 500 Lux, 25 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.025,0.025,0.025","Wire 600V #14 Stranded THWN-THHN
|
231
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
232
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
233
|
+
Steel Outlet boxes, on framing
|
234
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
235
|
+
",7.6,25
|
236
|
+
40,"LED Lighting 25 W LED suspended 250 Lux, 16 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
237
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
238
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
239
|
+
Steel Outlet boxes, on framing
|
240
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
241
|
+
",5.25,16
|
242
|
+
41,"LED Lighting 25 W LED suspended 600 Lux, 36 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,114",ft2,"0.003,0.128,0.036,0.036,0.036","Wire 600V #14 Stranded THWN-THHN
|
243
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
244
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
245
|
+
Steel Outlet boxes, on framing
|
246
|
+
Interior LED fixtures, linear, suspended mounted, 37 watt, one light bar 4' long, incl lamps, mounting hardware and connections
|
247
|
+
",10.36,36
|
248
|
+
42,"LED Lighting 87 W LED suspended 1000 Lux, 16 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,116",ft2,"0.003,0.128,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
249
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
250
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
251
|
+
Steel Outlet boxes, on framing
|
252
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
253
|
+
",15,16
|
254
|
+
43,"LED Lighting 87 W LED suspended 1600 Lux, 28 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,116",ft2,"0.003,0.128,0.028,0.028,0.028","Wire 600V #14 Stranded THWN-THHN
|
255
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
256
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
257
|
+
Steel Outlet boxes, on framing
|
258
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
259
|
+
",22,28
|
260
|
+
44,"LED Lighting 22 W strip LED suspended 150 Lux, 6 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,111",ft2,"0.003,0.128,0.006,0.006,0.006","Wire 600V #14 Stranded THWN-THHN
|
261
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
262
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
263
|
+
Steel Outlet boxes, on framing
|
264
|
+
Interior LED fixtures, strip, surface mounted, 37 Watts, 3500K, one light bar 4' long, incl lamps, mounting hardware and connections
|
265
|
+
",2.8,6
|
266
|
+
45,"LED Lighting 22 W strip LED suspended 350 Lux, 20 Fixtures/1000 Ft2 for max. 15 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,111",ft2,"0.003,0.128,0.02,0.02,0.02","Wire 600V #14 Stranded THWN-THHN
|
267
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
268
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
269
|
+
Steel Outlet boxes, on framing
|
270
|
+
Interior LED fixtures, strip, surface mounted, 37 Watts, 3500K, one light bar 4' long, incl lamps, mounting hardware and connections
|
271
|
+
",5,20
|
272
|
+
46,"LED Lighting 130 W High Bay LED suspended round 500 Lux, 4 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,118",ft2,"0.003,0.128,0.004, 0.004,0.004,0.004","Wire 600V #14 Stranded THWN-THHN
|
273
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
274
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
275
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
276
|
+
Steel Outlet boxes, on framing
|
277
|
+
Interior LED fixtures, high bay, surface mounted, round, 150 watt
|
278
|
+
",6.8,4
|
279
|
+
47,"LED Lighting 74 W High Bay LED suspended round 400 Lux, 9 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.009,0.009,0.009,0.009","Wire 600V #14 Stranded THWN-THHN
|
280
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
281
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
282
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
283
|
+
Steel Outlet boxes, on framing
|
284
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
285
|
+
",8,9
|
286
|
+
48,"LED Lighting 74 W High Bay LED suspended round 250 Lux, 6 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.006,0.006,0.006,0.006","Wire 600V #14 Stranded THWN-THHN
|
287
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
288
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
289
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
290
|
+
Steel Outlet boxes, on framing
|
291
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
292
|
+
",6.6,6
|
293
|
+
49,"LED Lighting 74 W High Bay LED suspended round 150 Lux, 4 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.004,0.004,0.004,0.004","Wire 600V #14 Stranded THWN-THHN
|
294
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
295
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
296
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
297
|
+
Steel Outlet boxes, on framing
|
298
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
299
|
+
",4.6,4
|
300
|
+
50,"LED Lighting 74 W High Bay LED suspended round 1500 Lux, 36 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.036,0.036,0.036,0.036","Wire 600V #14 Stranded THWN-THHN
|
301
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
302
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
303
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
304
|
+
Steel Outlet boxes, on framing
|
305
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
306
|
+
",23.6,36
|
307
|
+
51,"LED Lighting 74 W High Bay LED suspended round 1000 Lux, 25 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.025,0.025,0.025,0.025","Wire 600V #14 Stranded THWN-THHN
|
308
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
309
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
310
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
311
|
+
Steel Outlet boxes, on framing
|
312
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
313
|
+
",18.9,25
|
314
|
+
52,"LED Lighting 74 W High Bay LED suspended round 800 Lux, 20 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.02,0.02,0.02,0.02","Wire 600V #14 Stranded THWN-THHN
|
315
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
316
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
317
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
318
|
+
Steel Outlet boxes, on framing
|
319
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
320
|
+
",16.8,20
|
321
|
+
53,"LED Lighting 74 W High Bay LED suspended round 600 Lux, 16 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.016,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
322
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
323
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
324
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
325
|
+
Steel Outlet boxes, on framing
|
326
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
327
|
+
",11.2,16
|
328
|
+
54,"LED Lighting 74 W High Bay LED surface mount garage 500 Lux, 12 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,128",ft2,"0.003,0.128,0.012,0.012,0.012","Wire 600V #14 Stranded THWN-THHN
|
329
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
330
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
331
|
+
Steel Outlet boxes, on framing
|
332
|
+
Interior LED fixtures, garage, surface mounted, 103 watts
|
333
|
+
",7.7,12
|
334
|
+
55,"LED Lighting 54 W High Bay LED suspended 4 ft. 2-bar 300 Lux, 16 Fixtures/1000 Ft2 for max. 20 ft. ceilings",rs-means,Assembly,291904,"10,13,4,14,15,116",ft2,"0.003,0.128,0.016,0.016,0.016,0.016","Wire 600V #14 Stranded THWN-THHN
|
335
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
336
|
+
Fixture Hanger 0.75 in diameter 6 ft long
|
337
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
338
|
+
Steel Outlet boxes, on framing
|
339
|
+
Interior LED fixtures, linear, suspended mounted, 74 watt, two light bar 4' long, incl lamps, mounting hardware and connections
|
340
|
+
",9.4,16
|
341
|
+
56,"LED Lighting 74 W High Bay LED surface mount garage 500 Lux, 6 Fixtures/1000 Ft2 for max. 10 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,128",ft2,"0.003,0.128,0.006,0.006,0.006","Wire 600V #14 Stranded THWN-THHN
|
342
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
343
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
344
|
+
Steel Outlet boxes, on framing
|
345
|
+
Interior LED fixtures, garage, surface mounted, 103 watts
|
346
|
+
",4.2,6
|
347
|
+
57,"LED Lighting 13 W strip LED suspended 291 Lux, 20 Fixtures/1000 Ft2 for max. 8.5 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,284",ft2,"0.003,0.128,0.006,0.006,0.02","Wire 600V #14 Stranded THWN-THHN
|
348
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
349
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
350
|
+
Steel Outlet boxes, on framing
|
351
|
+
LED 13 watt dimmable warm white
|
352
|
+
",2.8,6
|
353
|
+
58,"LED Lighting 13 W strip LED suspended 291 Lux, 25 Fixtures/1000 Ft2 for max. 8.5 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,284",ft2,"0.003,0.128,0.006,0.006,0.025","Wire 600V #14 Stranded THWN-THHN
|
354
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
355
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
356
|
+
Steel Outlet boxes, on framing
|
357
|
+
LED 13 watt dimmable warm white
|
358
|
+
",2.8,6
|
359
|
+
59,"LED Lighting 13 W strip LED suspended 254 Lux, 16 Fixtures/1000 Ft2 for max. 8.5 ft. ceilings",rs-means,Assembly,291904,"10,13,14,15,284",ft2,"0.003,0.128,0.006,0.006,0.016","Wire 600V #14 Stranded THWN-THHN
|
360
|
+
Metal conduit. 0.5 in diamater, 11 coupling per 100 LF
|
361
|
+
Steel Outlet boxes, set flush in concrete 4 "" deep
|
362
|
+
Steel Outlet boxes, on framing
|
363
|
+
LED 13 watt dimmable warm white
|
364
|
+
",2.8,6
|