openstudio-standards 0.2.10 → 0.2.11.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +5 -5
- data/data/geometry/ASHRAE90120042007LargeHotel.osm +101 -0
- data/data/geometry/ASHRAE90120042007RetailStandalone.osm +220 -0
- data/data/geometry/ASHRAE9012010LargeHotel.osm +101 -0
- data/data/geometry/ASHRAE9012010RetailStandalone.osm +218 -32
- data/data/geometry/ASHRAE9012013FullServiceRestaurant.osm +17 -0
- data/data/geometry/ASHRAE9012013Hospital.osm +288 -0
- data/data/geometry/ASHRAE9012013LargeHotel.osm +113 -12
- data/data/geometry/ASHRAE9012013LargeOffice.osm +205 -1
- data/data/geometry/ASHRAE9012013MediumOffice.osm +103 -1
- data/data/geometry/ASHRAE9012013Outpatient.osm +390 -102
- data/data/geometry/ASHRAE9012013PrimarySchool.osm +424 -0
- data/data/geometry/ASHRAE9012013QuickServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAE9012013RetailStandalone.osm +220 -0
- data/data/geometry/ASHRAE9012013SecondarySchool.osm +543 -0
- data/data/geometry/ASHRAE9012013SmallHotel.osm +50 -0
- data/data/geometry/ASHRAE9012013SmallOffice.osm +33 -0
- data/data/geometry/ASHRAE9012013Warehouse.osm +475 -238
- data/data/geometry/ASHRAEFullServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAEHospital.osm +288 -0
- data/data/geometry/ASHRAELargeOffice.osm +205 -1
- data/data/geometry/ASHRAELargeOfficeDetailed.osm +32 -32
- data/data/geometry/ASHRAEMediumOffice.osm +103 -1
- data/data/geometry/ASHRAEOutpatient.osm +390 -102
- data/data/geometry/ASHRAEPrimarySchool.osm +424 -0
- data/data/geometry/ASHRAEQuickServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAESecondarySchool.osm +1011 -162
- data/data/geometry/ASHRAESmallHotel.osm +50 -0
- data/data/geometry/ASHRAESmallOffice.osm +33 -0
- data/data/geometry/ASHRAEWarehouse.osm +476 -238
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/openstudio_standards_duplicates_log.csv +16 -0
- data/data/standards/test_performance_expected_dd_results.csv +1216 -1216
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.ddy +536 -0
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.epw +8768 -0
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.stat +544 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.ddy +533 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.epw +8768 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.stat +553 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.ddy +533 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.epw +8768 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.stat +544 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.ddy +533 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.epw +8768 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.stat +546 -0
- data/lib/openstudio-standards.rb +27 -0
- data/lib/openstudio-standards/btap/btap.model.rb +4 -4
- data/lib/openstudio-standards/btap/btap_result.rb +8 -8
- data/lib/openstudio-standards/btap/economics.rb +11 -11
- data/lib/openstudio-standards/btap/envelope.rb +5 -5
- data/lib/openstudio-standards/btap/hvac.rb +55 -11
- data/lib/openstudio-standards/btap/measures.rb +7 -7
- data/lib/openstudio-standards/btap/spaceloads.rb +4 -4
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +105 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.ControllerOutdoorAir.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +6 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +9 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +3 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +22 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +9 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +35 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +17 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +22 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +107 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +15 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +45 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +21 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -364
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +4 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +4 -5
- data/lib/openstudio-standards/refs/references.rb +4 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +283 -97
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +53 -45
- data/lib/openstudio-standards/standards/Standards.Fan.rb +10 -2
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +39 -18
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +8 -8
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +12 -12
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Space.rb +190 -181
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +36 -59
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Surface.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +16 -12
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +16 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +1354 -1075
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +557 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +28 -28
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +233 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +1356 -1077
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +28 -28
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +241 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +12 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +1367 -1087
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +233 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +20 -27
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +1432 -1138
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +241 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.climate_zone_sets.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.climate_zones.json +39 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +489 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +250 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +1920 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +5265 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +2441 -1925
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.construction_properties.json +16658 -2578
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +212 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +11 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +2403 -1889
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.construction_properties.json +16664 -2584
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +209 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +11 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_properties.json +4113 -513
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_sets.json +40 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.elevators.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ground_temperatures.json +650 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps.json +90 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps_heating.json +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +1909 -32
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.water_heaters.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +147 -155
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +29 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +45 -73
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +4 -72
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.boilers.json +20 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.chillers.json +400 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_properties.json +4444 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_sets.json +391 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.economizers.json +536 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.elevators.json +36 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ground_temperatures.json +650 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps.json +290 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +40 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.prototype_inputs.json +704 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.refrigeration_compressors.json +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +6424 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.unitary_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +829 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +34 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +80 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +146 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ThermalZone.rb +23 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +8 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +16 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +18 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +5 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +5 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +5 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +8 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +12 -12
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +4 -0
- metadata +102 -18
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-cbes(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-cbes.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer.xlsx +0 -0
- data/data/standards/OpenStudio_Standards_LA100.xlsx +0 -0
- data/data/standards/junk/legacy_dd_results - Copy.csv +0 -960
- data/data/standards/junk/legacy_dd_results.csv +0 -960
- data/data/standards/junk/legacy_dd_results_new - Copy.csv +0 -960
- data/data/standards/junk/legacy_dd_results_new.csv +0 -960
- data/data/standards/junk/legacy_dd_results_original.csv +0 -960
- data/lib/openstudio-standards/standards/necb/NECB2011/newway.json +0 -8102
data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.25,
|
15
|
+
"pthp_cop_coefficient_2": 0.06,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.25,
|
15
|
+
"pthp_cop_coefficient_2": 0.06,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.25,
|
15
|
+
"pthp_cop_coefficient_2": 0.06,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.44,
|
15
|
+
"pthp_cop_coefficient_2": 0.063,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.44,
|
15
|
+
"pthp_cop_coefficient_2": 0.063,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.44,
|
15
|
+
"pthp_cop_coefficient_2": 0.063,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.81,
|
15
|
+
"pthp_cop_coefficient_2": 0.067,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 2.9,
|
15
|
+
"pthp_cop_coefficient_2": 0.026,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -70,7 +70,11 @@ class NECB2011
|
|
70
70
|
air_loop_sizing = mau_air_loop.sizingSystem # TODO units
|
71
71
|
air_loop_sizing.setTypeofLoadtoSizeOn('Sensible')
|
72
72
|
air_loop_sizing.autosizeDesignOutdoorAirFlowRate
|
73
|
-
|
73
|
+
if model.version < OpenStudio::VersionString.new('2.7.0')
|
74
|
+
air_loop_sizing.setMinimumSystemAirFlowRatio(1.0)
|
75
|
+
else
|
76
|
+
air_loop_sizing.setCentralHeatingMaximumSystemAirFlowRatio(1.0)
|
77
|
+
end
|
74
78
|
air_loop_sizing.setPreheatDesignTemperature(7.0)
|
75
79
|
air_loop_sizing.setPreheatDesignHumidityRatio(0.008)
|
76
80
|
air_loop_sizing.setPrecoolDesignTemperature(12.8)
|
@@ -49,7 +49,11 @@ class NECB2011
|
|
49
49
|
air_loop_sizing = air_loop.sizingSystem # TODO units
|
50
50
|
air_loop_sizing.setTypeofLoadtoSizeOn('Sensible')
|
51
51
|
air_loop_sizing.autosizeDesignOutdoorAirFlowRate
|
52
|
-
|
52
|
+
if model.version < OpenStudio::VersionString.new('2.7.0')
|
53
|
+
air_loop_sizing.setMinimumSystemAirFlowRatio(1.0)
|
54
|
+
else
|
55
|
+
air_loop_sizing.setCentralHeatingMaximumSystemAirFlowRatio(1.0)
|
56
|
+
end
|
53
57
|
air_loop_sizing.setPreheatDesignTemperature(7.0)
|
54
58
|
air_loop_sizing.setPreheatDesignHumidityRatio(0.008)
|
55
59
|
air_loop_sizing.setPrecoolDesignTemperature(13.0)
|
@@ -207,8 +207,11 @@ class NECB2011
|
|
207
207
|
air_loop_sizing.setCentralHeatingDesignSupplyAirTemperature(system_data[:CentralHeatingDesignSupplyAirTemperature] )
|
208
208
|
air_loop_sizing.setAllOutdoorAirinCooling(system_data[:AllOutdoorAirinCooling])
|
209
209
|
air_loop_sizing.setAllOutdoorAirinHeating(system_data[:AllOutdoorAirinHeating])
|
210
|
-
|
211
|
-
|
210
|
+
if model.version < OpenStudio::VersionString.new('2.7.0')
|
211
|
+
air_loop_sizing.setMinimumSystemAirFlowRatio(system_data[:MinimumSystemAirFlowRatio])
|
212
|
+
else
|
213
|
+
air_loop_sizing.setCentralHeatingMaximumSystemAirFlowRatio(system_data[:MinimumSystemAirFlowRatio])
|
214
|
+
end
|
212
215
|
|
213
216
|
supply_fan = OpenStudio::Model::FanVariableVolume.new(model, always_on)
|
214
217
|
supply_fan.setName('Sys6 Supply Fan')
|
@@ -284,7 +284,7 @@ class NECB2011
|
|
284
284
|
# @param (see #economizer_required?)
|
285
285
|
# @return [Bool] Returns true if required, false if not.
|
286
286
|
# @todo Add exception logic for systems serving parking garage, warehouse, or multifamily
|
287
|
-
def air_loop_hvac_apply_energy_recovery_ventilator(air_loop_hvac)
|
287
|
+
def air_loop_hvac_apply_energy_recovery_ventilator(air_loop_hvac, climate_zone)
|
288
288
|
# Get the oa system
|
289
289
|
oa_system = nil
|
290
290
|
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
@@ -1823,7 +1823,13 @@ class NECB2011
|
|
1823
1823
|
air_loop_sizing.setCentralHeatingDesignSupplyAirTemperature(system_data[:CentralHeatingDesignSupplyAirTemperature]) unless system_data[:CentralHeatingDesignSupplyAirTemperature].nil?
|
1824
1824
|
air_loop_sizing.setAllOutdoorAirinCooling(system_data[:AllOutdoorAirinCooling]) unless system_data[:AllOutdoorAirinCooling].nil?
|
1825
1825
|
air_loop_sizing.setAllOutdoorAirinHeating(system_data[:AllOutdoorAirinHeating]) unless system_data[:AllOutdoorAirinHeating].nil?
|
1826
|
-
|
1826
|
+
unless system_data[:MinimumSystemAirFlowRatio].nil?
|
1827
|
+
if model.version < OpenStudio::VersionString.new('2.7.0')
|
1828
|
+
air_loop_sizing.setMinimumSystemAirFlowRatio(system_data[:MinimumSystemAirFlowRatio])
|
1829
|
+
else
|
1830
|
+
air_loop_sizing.setCentralHeatingMaximumSystemAirFlowRatio(system_data[:MinimumSystemAirFlowRatio])
|
1831
|
+
end
|
1832
|
+
end
|
1827
1833
|
return mau_air_loop
|
1828
1834
|
end
|
1829
1835
|
|
@@ -653,7 +653,7 @@ class NECB2011
|
|
653
653
|
if !space.waterUseEquipment.empty?
|
654
654
|
waterUseEquipment_info={}
|
655
655
|
spaceinfo[:waterUseEquipment] << waterUseEquipment_info
|
656
|
-
waterUseEquipment_info[:peak_flow_rate]= space.waterUseEquipment[0].waterUseEquipmentDefinition.
|
656
|
+
waterUseEquipment_info[:peak_flow_rate]= space.waterUseEquipment[0].waterUseEquipmentDefinition.peakFlowRate
|
657
657
|
waterUseEquipment_info[:peak_flow_rate_per_area] = waterUseEquipment_info[:peak_flow_rate] / space.floorArea
|
658
658
|
area_per_occ = space.spaceType.get.people[0].spaceFloorAreaPerPerson
|
659
659
|
area_per_occ = validate_optional(area_per_occ, model, -1.0)
|
@@ -839,8 +839,8 @@ class NECB2011
|
|
839
839
|
air_loop_info[:cooling_coils][:dx_single_speed] << coil
|
840
840
|
single_speed = supply_comp.to_CoilCoolingDXSingleSpeed.get
|
841
841
|
coil[:name] = single_speed.name.get
|
842
|
-
coil[:cop] = single_speed.
|
843
|
-
coil[:nominal_total_capacity_w] = model.sqlFile
|
842
|
+
coil[:cop] = single_speed.ratedCOP.get
|
843
|
+
coil[:nominal_total_capacity_w] = model.sqlFile.get.execAndReturnFirstDouble("SELECT Value FROM TabularDataWithStrings WHERE ReportName='EquipmentSummary' AND ReportForString='Entire Facility' AND TableName='Cooling Coils' AND ColumnName='Nominal Total Capacity' AND RowName='#{coil[:name].upcase}' ")
|
844
844
|
coil[:nominal_total_capacity_w] = validate_optional(coil[:nominal_total_capacity_w], model, -1.0)
|
845
845
|
end
|
846
846
|
if supply_comp.to_CoilCoolingDXTwoSpeed.is_initialized
|
@@ -848,9 +848,9 @@ class NECB2011
|
|
848
848
|
air_loop_info[:cooling_coils][:dx_two_speed] << coil
|
849
849
|
two_speed = supply_comp.to_CoilCoolingDXTwoSpeed.get
|
850
850
|
coil[:name] = two_speed.name.get
|
851
|
-
coil[:cop_low] = two_speed.
|
852
|
-
coil[:cop_high] = two_speed.
|
853
|
-
coil[:nominal_total_capacity_w] = model.sqlFile
|
851
|
+
coil[:cop_low] = two_speed.ratedLowSpeedCOP.get
|
852
|
+
coil[:cop_high] = two_speed.ratedHighSpeedCOP.get
|
853
|
+
coil[:nominal_total_capacity_w] = model.sqlFile.get.execAndReturnFirstDouble("SELECT Value FROM TabularDataWithStrings WHERE ReportName='EquipmentSummary' AND ReportForString='Entire Facility' AND TableName='Cooling Coils' AND ColumnName='Nominal Total Capacity' AND RowName='#{coil[:name].upcase}' ")
|
854
854
|
coil[:nominal_total_capacity_w] = validate_optional(coil[:nominal_total_capacity_w], model, -1.0)
|
855
855
|
end
|
856
856
|
if supply_comp.to_CoilCoolingWater.is_initialized
|
@@ -858,9 +858,9 @@ class NECB2011
|
|
858
858
|
air_loop_info[:cooling_coils][:coil_cooling_water] << coil
|
859
859
|
coil_cooling_water = supply_comp.to_CoilCoolingWater.get
|
860
860
|
coil[:name] = coil_cooling_water.name.get
|
861
|
-
coil[:nominal_total_capacity_w] = model.sqlFile
|
861
|
+
coil[:nominal_total_capacity_w] = model.sqlFile.get.execAndReturnFirstDouble("SELECT Value FROM TabularDataWithStrings WHERE ReportName='EquipmentSummary' AND ReportForString='Entire Facility' AND TableName='Cooling Coils' AND ColumnName='Nominal Total Capacity' AND RowName='#{coil[:name].upcase}' ")
|
862
862
|
coil[:nominal_total_capacity_w] = validate_optional(coil[:nominal_total_capacity_w], model, -1.0)
|
863
|
-
coil[:nominal_sensible_heat_ratio] = model.sqlFile
|
863
|
+
coil[:nominal_sensible_heat_ratio] = model.sqlFile.get.execAndReturnFirstDouble("SELECT Value FROM TabularDataWithStrings WHERE ReportName='EquipmentSummary' AND ReportForString='Entire Facility' AND TableName='Cooling Coils' AND ColumnName='Nominal Sensible Heat Ratio' AND RowName='#{coil[:name].upcase}' ")
|
864
864
|
coil[:nominal_sensible_heat_ratio] = validate_optional(coil[:nominal_sensible_heat_ratio], model, -1.0)
|
865
865
|
end
|
866
866
|
end
|
@@ -875,8 +875,8 @@ class NECB2011
|
|
875
875
|
plant_loop_info[:name] = plant_loop.name.get
|
876
876
|
|
877
877
|
sizing = plant_loop.sizingPlant
|
878
|
-
plant_loop_info[:design_loop_exit_temperature] = sizing.
|
879
|
-
plant_loop_info[:loop_design_temperature_difference] = sizing.
|
878
|
+
plant_loop_info[:design_loop_exit_temperature] = sizing.designLoopExitTemperature
|
879
|
+
plant_loop_info[:loop_design_temperature_difference] = sizing.loopDesignTemperatureDifference
|
880
880
|
|
881
881
|
#Create Container for plant equipment arrays.
|
882
882
|
plant_loop_info[:pumps] = []
|
@@ -899,7 +899,7 @@ class NECB2011
|
|
899
899
|
pump_info[:water_flow_m3_per_s] = validate_optional(pump_info[:water_flow_m3_per_s], model, -1.0)
|
900
900
|
pump_info[:electric_power_w] = model.sqlFile().get().execAndReturnFirstDouble("SELECT Value FROM TabularDataWithStrings WHERE ReportName='EquipmentSummary' AND ReportForString='Entire Facility' AND TableName='Pumps' AND ColumnName='Electric Power' AND RowName='#{pump_info[:name].upcase}' ")
|
901
901
|
pump_info[:electric_power_w] = validate_optional(pump_info[:electric_power_w], model, -1.0)
|
902
|
-
pump_info[:motor_efficency] = pump.
|
902
|
+
pump_info[:motor_efficency] = pump.motorEfficiency
|
903
903
|
end
|
904
904
|
|
905
905
|
#Collect Variable Speed
|
@@ -915,7 +915,7 @@ class NECB2011
|
|
915
915
|
pump_info[:water_flow_m3_per_s] = validate_optional(pump_info[:water_flow_m3_per_s], model, -1.0)
|
916
916
|
pump_info[:electric_power_w] = model.sqlFile().get().execAndReturnFirstDouble("SELECT Value FROM TabularDataWithStrings WHERE ReportName='EquipmentSummary' AND ReportForString='Entire Facility' AND TableName='Pumps' AND ColumnName='Electric Power' AND RowName='#{pump_info[:name].upcase}' ")
|
917
917
|
pump_info[:electric_power_w] = validate_optional(pump_info[:electric_power_w], model, -1.0)
|
918
|
-
pump_info[:motor_efficency] = pump.
|
918
|
+
pump_info[:motor_efficency] = pump.motorEfficiency
|
919
919
|
end
|
920
920
|
|
921
921
|
# Collect HotWaterBoilers
|
@@ -14,6 +14,8 @@ class Standard
|
|
14
14
|
|
15
15
|
# Define the weather file for each climate zone
|
16
16
|
climate_zone_weather_file_map = {
|
17
|
+
'ASHRAE 169-2006-0A' => 'VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.epw',
|
18
|
+
'ASHRAE 169-2006-0B' => 'ARE_Dubai.Intl.AP.411940_IWEC2.epw',
|
17
19
|
'ASHRAE 169-2006-1A' => 'USA_FL_Miami.Intl.AP.722020_TMY3.epw',
|
18
20
|
'ASHRAE 169-2006-1B' => 'SAU_Riyadh.404380_IWEC.epw',
|
19
21
|
'ASHRAE 169-2006-2A' => 'USA_TX_Houston-Bush.Intercontinental.AP.722430_TMY3.epw',
|
@@ -33,6 +35,8 @@ class Standard
|
|
33
35
|
'ASHRAE 169-2006-7B' => 'USA_MN_Duluth.Intl.AP.727450_TMY3.epw',
|
34
36
|
'ASHRAE 169-2006-8A' => 'USA_AK_Fairbanks.Intl.AP.702610_TMY3.epw',
|
35
37
|
'ASHRAE 169-2006-8B' => 'USA_AK_Fairbanks.Intl.AP.702610_TMY3.epw',
|
38
|
+
'ASHRAE 169-2013-0A' => 'VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.epw',
|
39
|
+
'ASHRAE 169-2013-0B' => 'ARE_Dubai.Intl.AP.411940_IWEC2.epw',
|
36
40
|
'ASHRAE 169-2013-1A' => 'USA_HI_Honolulu.Intl.AP.911820_TMY3.epw',
|
37
41
|
'ASHRAE 169-2013-1B' => 'IND_Delhi_New.Delhi-Safdarjung.AP.421820_IWEC2.epw',
|
38
42
|
'ASHRAE 169-2013-2A' => 'USA_FL_Tampa-MacDill.AFB.747880_TMY3.epw',
|
metadata
CHANGED
@@ -1,7 +1,7 @@
|
|
1
1
|
--- !ruby/object:Gem::Specification
|
2
2
|
name: openstudio-standards
|
3
3
|
version: !ruby/object:Gem::Version
|
4
|
-
version: 0.2.
|
4
|
+
version: 0.2.11.rc1
|
5
5
|
platform: ruby
|
6
6
|
authors:
|
7
7
|
- Andrew Parker
|
@@ -22,7 +22,7 @@ authors:
|
|
22
22
|
autorequire:
|
23
23
|
bindir: bin
|
24
24
|
cert_chain: []
|
25
|
-
date:
|
25
|
+
date: 2020-03-19 00:00:00.000000000 Z
|
26
26
|
dependencies:
|
27
27
|
- !ruby/object:Gem::Dependency
|
28
28
|
name: minitest-reporters
|
@@ -234,6 +234,34 @@ dependencies:
|
|
234
234
|
- - '='
|
235
235
|
- !ruby/object:Gem::Version
|
236
236
|
version: 0.15.4
|
237
|
+
- !ruby/object:Gem::Dependency
|
238
|
+
name: signet
|
239
|
+
requirement: !ruby/object:Gem::Requirement
|
240
|
+
requirements:
|
241
|
+
- - "<"
|
242
|
+
- !ruby/object:Gem::Version
|
243
|
+
version: 0.12.0
|
244
|
+
type: :development
|
245
|
+
prerelease: false
|
246
|
+
version_requirements: !ruby/object:Gem::Requirement
|
247
|
+
requirements:
|
248
|
+
- - "<"
|
249
|
+
- !ruby/object:Gem::Version
|
250
|
+
version: 0.12.0
|
251
|
+
- !ruby/object:Gem::Dependency
|
252
|
+
name: launchy
|
253
|
+
requirement: !ruby/object:Gem::Requirement
|
254
|
+
requirements:
|
255
|
+
- - "<"
|
256
|
+
- !ruby/object:Gem::Version
|
257
|
+
version: 2.5.0
|
258
|
+
type: :development
|
259
|
+
prerelease: false
|
260
|
+
version_requirements: !ruby/object:Gem::Requirement
|
261
|
+
requirements:
|
262
|
+
- - "<"
|
263
|
+
- !ruby/object:Gem::Version
|
264
|
+
version: 2.5.0
|
237
265
|
- !ruby/object:Gem::Dependency
|
238
266
|
name: google-api-client
|
239
267
|
requirement: !ruby/object:Gem::Requirement
|
@@ -248,6 +276,20 @@ dependencies:
|
|
248
276
|
- - '='
|
249
277
|
- !ruby/object:Gem::Version
|
250
278
|
version: 0.8.6
|
279
|
+
- !ruby/object:Gem::Dependency
|
280
|
+
name: simplecov-html
|
281
|
+
requirement: !ruby/object:Gem::Requirement
|
282
|
+
requirements:
|
283
|
+
- - "<"
|
284
|
+
- !ruby/object:Gem::Version
|
285
|
+
version: 0.11.0
|
286
|
+
type: :development
|
287
|
+
prerelease: false
|
288
|
+
version_requirements: !ruby/object:Gem::Requirement
|
289
|
+
requirements:
|
290
|
+
- - "<"
|
291
|
+
- !ruby/object:Gem::Version
|
292
|
+
version: 0.11.0
|
251
293
|
- !ruby/object:Gem::Dependency
|
252
294
|
name: codecov
|
253
295
|
requirement: !ruby/object:Gem::Requirement
|
@@ -631,24 +673,11 @@ files:
|
|
631
673
|
- data/geometry/DOERefSmallOffice.json
|
632
674
|
- data/geometry/DOERefWarehouse.json
|
633
675
|
- data/geometry/DOERefWarehouse.osm
|
634
|
-
- data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx
|
635
|
-
- data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx
|
636
|
-
- data/standards/OpenStudio_Standards-ashrae_90_1.xlsx
|
637
|
-
- data/standards/OpenStudio_Standards-cbes(space_types).xlsx
|
638
|
-
- data/standards/OpenStudio_Standards-cbes.xlsx
|
639
|
-
- data/standards/OpenStudio_Standards-deer(space_types).xlsx
|
640
|
-
- data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx
|
641
|
-
- data/standards/OpenStudio_Standards-deer.xlsx
|
642
|
-
- data/standards/OpenStudio_Standards_LA100.xlsx
|
643
676
|
- data/standards/OpenStudio_Standards_space_types.json
|
644
677
|
- data/standards/export_OpenStudio_libraries.rb
|
645
|
-
- data/standards/junk/legacy_dd_results - Copy.csv
|
646
|
-
- data/standards/junk/legacy_dd_results.csv
|
647
|
-
- data/standards/junk/legacy_dd_results_new - Copy.csv
|
648
|
-
- data/standards/junk/legacy_dd_results_new.csv
|
649
|
-
- data/standards/junk/legacy_dd_results_original.csv
|
650
678
|
- data/standards/legacy_idf_results.csv
|
651
679
|
- data/standards/manage_OpenStudio_Standards.rb
|
680
|
+
- data/standards/openstudio_standards_duplicates_log.csv
|
652
681
|
- data/standards/templates_to_climate_zones.json
|
653
682
|
- data/standards/test_performance_expected_dd_results.csv
|
654
683
|
- data/weather/ALTURAS_725958_CZ2010.ddy
|
@@ -657,6 +686,12 @@ files:
|
|
657
686
|
- data/weather/ARCATA_725945_CZ2010.ddy
|
658
687
|
- data/weather/ARCATA_725945_CZ2010.epw
|
659
688
|
- data/weather/ARCATA_725945_CZ2010.stat
|
689
|
+
- data/weather/ARE_Abu.Dhabi.412170_IWEC.ddy
|
690
|
+
- data/weather/ARE_Abu.Dhabi.412170_IWEC.epw
|
691
|
+
- data/weather/ARE_Abu.Dhabi.412170_IWEC.stat
|
692
|
+
- data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.ddy
|
693
|
+
- data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.epw
|
694
|
+
- data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.stat
|
660
695
|
- data/weather/BAKERSFIELD_723840_CZ2010.ddy
|
661
696
|
- data/weather/BAKERSFIELD_723840_CZ2010.epw
|
662
697
|
- data/weather/BAKERSFIELD_723840_CZ2010.stat
|
@@ -1233,6 +1268,12 @@ files:
|
|
1233
1268
|
- data/weather/VISALIA_723896_CZ2010.ddy
|
1234
1269
|
- data/weather/VISALIA_723896_CZ2010.epw
|
1235
1270
|
- data/weather/VISALIA_723896_CZ2010.stat
|
1271
|
+
- data/weather/VNM_Hanoi.488200_IWEC.ddy
|
1272
|
+
- data/weather/VNM_Hanoi.488200_IWEC.epw
|
1273
|
+
- data/weather/VNM_Hanoi.488200_IWEC.stat
|
1274
|
+
- data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.ddy
|
1275
|
+
- data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.epw
|
1276
|
+
- data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.stat
|
1236
1277
|
- data/weather/Wth_Processing/CAN_NF_Battle.Harbour.718170_CWECEPW.csv
|
1237
1278
|
- data/weather/Wth_Processing/CAN_NS_Truro.713980_CWECEPW.csv
|
1238
1279
|
- data/weather/Wth_Processing/CAN_ON_Kingston.716200_CWECEPW.csv
|
@@ -1380,9 +1421,18 @@ files:
|
|
1380
1421
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanConstantVolume.rb
|
1381
1422
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanOnOff.rb
|
1382
1423
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.FanVariableVolume.rb
|
1424
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb
|
1383
1425
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
|
1384
1426
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb
|
1385
1427
|
- lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.hvac_systems.rb
|
1428
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb
|
1429
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb
|
1430
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb
|
1431
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb
|
1432
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb
|
1433
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb
|
1434
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb
|
1435
|
+
- lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb
|
1386
1436
|
- lib/openstudio-standards/prototypes/cbes/cbes.Model.elevators.rb
|
1387
1437
|
- lib/openstudio-standards/prototypes/cbes/cbes.refrigeration.rb
|
1388
1438
|
- lib/openstudio-standards/prototypes/cbes/cbes_t24_2008/cbes_t24_2008.FanConstantVolume.rb
|
@@ -1740,6 +1790,7 @@ files:
|
|
1740
1790
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.economizers.json
|
1741
1791
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.elevators.json
|
1742
1792
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ext_ltg.json
|
1793
|
+
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ground_temperatures.json
|
1743
1794
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps.json
|
1744
1795
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps_heating.json
|
1745
1796
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_rejection.json
|
@@ -1765,6 +1816,39 @@ files:
|
|
1765
1816
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ThermalZone.rb
|
1766
1817
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb
|
1767
1818
|
- lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.rb
|
1819
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.boilers.json
|
1820
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.chillers.json
|
1821
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_properties.json
|
1822
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_sets.json
|
1823
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.economizers.json
|
1824
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.elevators.json
|
1825
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ext_ltg.json
|
1826
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ground_temperatures.json
|
1827
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps.json
|
1828
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps_heating.json
|
1829
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json
|
1830
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.motors.json
|
1831
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.prototype_inputs.json
|
1832
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.refrigeration_compressors.json
|
1833
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json
|
1834
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.unitary_acs.json
|
1835
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json
|
1836
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps.json
|
1837
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps_heating.json
|
1838
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb
|
1839
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb
|
1840
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb
|
1841
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerSingleSpeed.rb
|
1842
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerTwoSpeed.rb
|
1843
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb
|
1844
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb
|
1845
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb
|
1846
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb
|
1847
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb
|
1848
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb
|
1849
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ThermalZone.rb
|
1850
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb
|
1851
|
+
- lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb
|
1768
1852
|
- lib/openstudio-standards/standards/cbes/cbes.AirLoopHVAC.rb
|
1769
1853
|
- lib/openstudio-standards/standards/cbes/cbes.Model.rb
|
1770
1854
|
- lib/openstudio-standards/standards/cbes/cbes.PlantLoop.rb
|
@@ -1923,6 +2007,7 @@ files:
|
|
1923
2007
|
- lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.chillers.json
|
1924
2008
|
- lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.construction_properties.json
|
1925
2009
|
- lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.construction_sets.json
|
2010
|
+
- lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json
|
1926
2011
|
- lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.elevators.json
|
1927
2012
|
- lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.ext_ltg.json
|
1928
2013
|
- lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.heat_pumps.json
|
@@ -2503,7 +2588,6 @@ files:
|
|
2503
2588
|
- lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb
|
2504
2589
|
- lib/openstudio-standards/standards/necb/NECB2011/lighting.rb
|
2505
2590
|
- lib/openstudio-standards/standards/necb/NECB2011/necb_2011.rb
|
2506
|
-
- lib/openstudio-standards/standards/necb/NECB2011/newway.json
|
2507
2591
|
- lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb
|
2508
2592
|
- lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_data/design_supply_temp.json
|
2509
2593
|
- lib/openstudio-standards/standards/necb/NECB2011/qaqc/qaqc_data/economizer.json
|
@@ -2587,7 +2671,7 @@ required_rubygems_version: !ruby/object:Gem::Requirement
|
|
2587
2671
|
version: 1.3.6
|
2588
2672
|
requirements: []
|
2589
2673
|
rubyforge_project:
|
2590
|
-
rubygems_version: 2.
|
2674
|
+
rubygems_version: 2.4.5.1
|
2591
2675
|
signing_key:
|
2592
2676
|
specification_version: 4
|
2593
2677
|
summary: Creates DOE Prototype building models and transforms proposed OpenStudio
|