openstudio-standards 0.2.10 → 0.2.11.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +5 -5
- data/data/geometry/ASHRAE90120042007LargeHotel.osm +101 -0
- data/data/geometry/ASHRAE90120042007RetailStandalone.osm +220 -0
- data/data/geometry/ASHRAE9012010LargeHotel.osm +101 -0
- data/data/geometry/ASHRAE9012010RetailStandalone.osm +218 -32
- data/data/geometry/ASHRAE9012013FullServiceRestaurant.osm +17 -0
- data/data/geometry/ASHRAE9012013Hospital.osm +288 -0
- data/data/geometry/ASHRAE9012013LargeHotel.osm +113 -12
- data/data/geometry/ASHRAE9012013LargeOffice.osm +205 -1
- data/data/geometry/ASHRAE9012013MediumOffice.osm +103 -1
- data/data/geometry/ASHRAE9012013Outpatient.osm +390 -102
- data/data/geometry/ASHRAE9012013PrimarySchool.osm +424 -0
- data/data/geometry/ASHRAE9012013QuickServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAE9012013RetailStandalone.osm +220 -0
- data/data/geometry/ASHRAE9012013SecondarySchool.osm +543 -0
- data/data/geometry/ASHRAE9012013SmallHotel.osm +50 -0
- data/data/geometry/ASHRAE9012013SmallOffice.osm +33 -0
- data/data/geometry/ASHRAE9012013Warehouse.osm +475 -238
- data/data/geometry/ASHRAEFullServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAEHospital.osm +288 -0
- data/data/geometry/ASHRAELargeOffice.osm +205 -1
- data/data/geometry/ASHRAELargeOfficeDetailed.osm +32 -32
- data/data/geometry/ASHRAEMediumOffice.osm +103 -1
- data/data/geometry/ASHRAEOutpatient.osm +390 -102
- data/data/geometry/ASHRAEPrimarySchool.osm +424 -0
- data/data/geometry/ASHRAEQuickServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAESecondarySchool.osm +1011 -162
- data/data/geometry/ASHRAESmallHotel.osm +50 -0
- data/data/geometry/ASHRAESmallOffice.osm +33 -0
- data/data/geometry/ASHRAEWarehouse.osm +476 -238
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/openstudio_standards_duplicates_log.csv +16 -0
- data/data/standards/test_performance_expected_dd_results.csv +1216 -1216
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.ddy +536 -0
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.epw +8768 -0
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.stat +544 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.ddy +533 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.epw +8768 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.stat +553 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.ddy +533 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.epw +8768 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.stat +544 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.ddy +533 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.epw +8768 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.stat +546 -0
- data/lib/openstudio-standards.rb +27 -0
- data/lib/openstudio-standards/btap/btap.model.rb +4 -4
- data/lib/openstudio-standards/btap/btap_result.rb +8 -8
- data/lib/openstudio-standards/btap/economics.rb +11 -11
- data/lib/openstudio-standards/btap/envelope.rb +5 -5
- data/lib/openstudio-standards/btap/hvac.rb +55 -11
- data/lib/openstudio-standards/btap/measures.rb +7 -7
- data/lib/openstudio-standards/btap/spaceloads.rb +4 -4
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +105 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.ControllerOutdoorAir.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +6 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +9 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +3 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +22 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +9 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +35 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +17 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +22 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +107 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +15 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +45 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +21 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -364
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +4 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +4 -5
- data/lib/openstudio-standards/refs/references.rb +4 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +283 -97
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +53 -45
- data/lib/openstudio-standards/standards/Standards.Fan.rb +10 -2
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +39 -18
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +8 -8
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +12 -12
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Space.rb +190 -181
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +36 -59
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Surface.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +16 -12
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +16 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +1354 -1075
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +557 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +28 -28
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +233 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +1356 -1077
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +28 -28
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +241 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +12 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +1367 -1087
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +233 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +20 -27
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +1432 -1138
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +241 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.climate_zone_sets.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.climate_zones.json +39 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +489 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +250 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +1920 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +5265 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +2441 -1925
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.construction_properties.json +16658 -2578
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +212 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +11 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +2403 -1889
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.construction_properties.json +16664 -2584
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +209 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +11 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_properties.json +4113 -513
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_sets.json +40 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.elevators.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ground_temperatures.json +650 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps.json +90 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps_heating.json +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +1909 -32
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.water_heaters.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +147 -155
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +29 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +45 -73
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +4 -72
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.boilers.json +20 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.chillers.json +400 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_properties.json +4444 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_sets.json +391 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.economizers.json +536 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.elevators.json +36 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ground_temperatures.json +650 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps.json +290 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +40 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.prototype_inputs.json +704 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.refrigeration_compressors.json +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +6424 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.unitary_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +829 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +34 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +80 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +146 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ThermalZone.rb +23 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +8 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +16 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +18 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +5 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +5 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +5 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +8 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +12 -12
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +4 -0
- metadata +102 -18
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-cbes(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-cbes.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer.xlsx +0 -0
- data/data/standards/OpenStudio_Standards_LA100.xlsx +0 -0
- data/data/standards/junk/legacy_dd_results - Copy.csv +0 -960
- data/data/standards/junk/legacy_dd_results.csv +0 -960
- data/data/standards/junk/legacy_dd_results_new - Copy.csv +0 -960
- data/data/standards/junk/legacy_dd_results_new.csv +0 -960
- data/data/standards/junk/legacy_dd_results_original.csv +0 -960
- data/lib/openstudio-standards/standards/necb/NECB2011/newway.json +0 -8102
@@ -0,0 +1,23 @@
|
|
1
|
+
class ZEAEDGMultifamily < ASHRAE901
|
2
|
+
# @!group ThermalZone
|
3
|
+
|
4
|
+
# Determine the area and occupancy level limits for
|
5
|
+
# demand control ventilation.
|
6
|
+
#
|
7
|
+
# @param thermal_zone [OpenStudio::Model::ThermalZone] the thermal zone
|
8
|
+
# @return [Array<Double>] the minimum area, in m^2
|
9
|
+
# and the minimum occupancy density in m^2/person. Returns nil
|
10
|
+
# if there is no requirement.
|
11
|
+
def thermal_zone_demand_control_ventilation_limits(thermal_zone)
|
12
|
+
min_area_ft2 = 500
|
13
|
+
min_occ_per_1000_ft2 = 12 # half of 90.1-2013
|
14
|
+
|
15
|
+
# Convert to SI
|
16
|
+
min_area_m2 = OpenStudio.convert(min_area_ft2, 'ft^2', 'm^2').get
|
17
|
+
min_occ_per_ft2 = min_occ_per_1000_ft2 / 1000.0
|
18
|
+
min_ft2_per_occ = 1.0 / min_occ_per_ft2
|
19
|
+
min_m2_per_occ = OpenStudio.convert(min_ft2_per_occ, 'ft^2', 'm^2').get
|
20
|
+
|
21
|
+
return [min_area_m2, min_m2_per_occ]
|
22
|
+
end
|
23
|
+
end
|
data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb
ADDED
@@ -0,0 +1,16 @@
|
|
1
|
+
# This class holds methods that apply the "standard" assumptions
|
2
|
+
# for Zero Energy Advanced Energy Design Guide for Multifamily Buildings to a given model.
|
3
|
+
# @ref [References::ZEAEDGMultifamily]
|
4
|
+
class ZEAEDGMultifamily < ASHRAE901
|
5
|
+
register_standard 'ZE AEDG Multifamily'
|
6
|
+
attr_reader :template
|
7
|
+
|
8
|
+
def initialize
|
9
|
+
@template = 'ZE AEDG Multifamily'
|
10
|
+
load_standards_database
|
11
|
+
end
|
12
|
+
|
13
|
+
def load_standards_database(data_directories = [])
|
14
|
+
super([__dir__] + data_directories)
|
15
|
+
end
|
16
|
+
end
|
data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 2.9,
|
15
|
+
"pthp_cop_coefficient_2": 0.026,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -0,0 +1,18 @@
|
|
1
|
+
{
|
2
|
+
"economizers": [
|
3
|
+
{
|
4
|
+
"template": "DEER 1996",
|
5
|
+
"climate_zone": "Any",
|
6
|
+
"data_center": false,
|
7
|
+
"capacity_limit": null,
|
8
|
+
"notes": "From MASControl2"
|
9
|
+
},
|
10
|
+
{
|
11
|
+
"template": "DEER 1996",
|
12
|
+
"climate_zone": "Any",
|
13
|
+
"data_center": true,
|
14
|
+
"capacity_limit": null,
|
15
|
+
"notes": "From MASControl2"
|
16
|
+
}
|
17
|
+
]
|
18
|
+
}
|
data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 2.9,
|
15
|
+
"pthp_cop_coefficient_2": 0.026,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 3.2,
|
15
|
+
"pthp_cop_coefficient_2": 0.026,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 3.2,
|
15
|
+
"pthp_cop_coefficient_2": 0.026,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 3.2,
|
15
|
+
"pthp_cop_coefficient_2": 0.026,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 3.7,
|
15
|
+
"pthp_cop_coefficient_2": 0.052,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 3.7,
|
15
|
+
"pthp_cop_coefficient_2": 0.052,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.heat_pumps_heating.json
CHANGED
@@ -5,7 +5,7 @@
|
|
5
5
|
"cooling_type": "AirCooled",
|
6
6
|
"subcategory": "Split System",
|
7
7
|
"minimum_capacity": 0.0,
|
8
|
-
"maximum_capacity":
|
8
|
+
"maximum_capacity": 9999999.0,
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 3.9,
|
15
|
+
"pthp_cop_coefficient_2": 0.055,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 3.9,
|
15
|
+
"pthp_cop_coefficient_2": 0.055,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.07,
|
15
|
+
"pthp_cop_coefficient_2": 0.057,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.07,
|
15
|
+
"pthp_cop_coefficient_2": 0.057,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|
data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.heat_pumps_heating.json
CHANGED
@@ -9,10 +9,10 @@
|
|
9
9
|
"start_date": "1919-09-09T00:00:00+00:00",
|
10
10
|
"end_date": "2999-09-09T00:00:00+00:00",
|
11
11
|
"minimum_heating_seasonal_performance_factor": null,
|
12
|
-
"minimum_coefficient_of_performance_heating":
|
12
|
+
"minimum_coefficient_of_performance_heating": null,
|
13
13
|
"minimum_energy_efficiency_ratio": null,
|
14
|
-
"pthp_cop_coefficient_1":
|
15
|
-
"pthp_cop_coefficient_2":
|
14
|
+
"pthp_cop_coefficient_1": 4.07,
|
15
|
+
"pthp_cop_coefficient_2": 0.057,
|
16
16
|
"heat_cap_ft": "DX-Heat-Cap-fEDB&OAT",
|
17
17
|
"heat_cap_fflow": "DXHEAT-NECB2011-REF-CAPFFLOW",
|
18
18
|
"heat_eir_ft": "PTAC-EIR-fEWB&OAT",
|
@@ -25,7 +25,7 @@
|
|
25
25
|
"cooling_type": "AirCooled",
|
26
26
|
"subcategory": "Single Package",
|
27
27
|
"minimum_capacity": 0.0,
|
28
|
-
"maximum_capacity":
|
28
|
+
"maximum_capacity": 9999999.0,
|
29
29
|
"start_date": "1919-09-09T00:00:00+00:00",
|
30
30
|
"end_date": "2999-09-09T00:00:00+00:00",
|
31
31
|
"minimum_heating_seasonal_performance_factor": null,
|
@@ -45,7 +45,7 @@
|
|
45
45
|
"cooling_type": "AirCooled",
|
46
46
|
"subcategory": "Split System",
|
47
47
|
"minimum_capacity": 0.0,
|
48
|
-
"maximum_capacity":
|
48
|
+
"maximum_capacity": 9999999.0,
|
49
49
|
"start_date": "1919-09-09T00:00:00+00:00",
|
50
50
|
"end_date": "2999-09-09T00:00:00+00:00",
|
51
51
|
"minimum_heating_seasonal_performance_factor": null,
|