openstudio-standards 0.2.10 → 0.2.11.rc1
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +5 -5
- data/data/geometry/ASHRAE90120042007LargeHotel.osm +101 -0
- data/data/geometry/ASHRAE90120042007RetailStandalone.osm +220 -0
- data/data/geometry/ASHRAE9012010LargeHotel.osm +101 -0
- data/data/geometry/ASHRAE9012010RetailStandalone.osm +218 -32
- data/data/geometry/ASHRAE9012013FullServiceRestaurant.osm +17 -0
- data/data/geometry/ASHRAE9012013Hospital.osm +288 -0
- data/data/geometry/ASHRAE9012013LargeHotel.osm +113 -12
- data/data/geometry/ASHRAE9012013LargeOffice.osm +205 -1
- data/data/geometry/ASHRAE9012013MediumOffice.osm +103 -1
- data/data/geometry/ASHRAE9012013Outpatient.osm +390 -102
- data/data/geometry/ASHRAE9012013PrimarySchool.osm +424 -0
- data/data/geometry/ASHRAE9012013QuickServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAE9012013RetailStandalone.osm +220 -0
- data/data/geometry/ASHRAE9012013SecondarySchool.osm +543 -0
- data/data/geometry/ASHRAE9012013SmallHotel.osm +50 -0
- data/data/geometry/ASHRAE9012013SmallOffice.osm +33 -0
- data/data/geometry/ASHRAE9012013Warehouse.osm +475 -238
- data/data/geometry/ASHRAEFullServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAEHospital.osm +288 -0
- data/data/geometry/ASHRAELargeOffice.osm +205 -1
- data/data/geometry/ASHRAELargeOfficeDetailed.osm +32 -32
- data/data/geometry/ASHRAEMediumOffice.osm +103 -1
- data/data/geometry/ASHRAEOutpatient.osm +390 -102
- data/data/geometry/ASHRAEPrimarySchool.osm +424 -0
- data/data/geometry/ASHRAEQuickServiceRestaurant.osm +16 -0
- data/data/geometry/ASHRAESecondarySchool.osm +1011 -162
- data/data/geometry/ASHRAESmallHotel.osm +50 -0
- data/data/geometry/ASHRAESmallOffice.osm +33 -0
- data/data/geometry/ASHRAEWarehouse.osm +476 -238
- data/data/standards/manage_OpenStudio_Standards.rb +1 -1
- data/data/standards/openstudio_standards_duplicates_log.csv +16 -0
- data/data/standards/test_performance_expected_dd_results.csv +1216 -1216
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.ddy +536 -0
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.epw +8768 -0
- data/data/weather/ARE_Abu.Dhabi.412170_IWEC.stat +544 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.ddy +533 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.epw +8768 -0
- data/data/weather/ARE_Dubai.Intl.AP.411940_IWEC2.stat +553 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.ddy +533 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.epw +8768 -0
- data/data/weather/VNM_Hanoi.488200_IWEC.stat +544 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.ddy +533 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.epw +8768 -0
- data/data/weather/VNM_Ho.Chi.Minh.City-Tan.Son.Nhat.AP.489000_IWEC2.stat +546 -0
- data/lib/openstudio-standards.rb +27 -0
- data/lib/openstudio-standards/btap/btap.model.rb +4 -4
- data/lib/openstudio-standards/btap/btap_result.rb +8 -8
- data/lib/openstudio-standards/btap/economics.rb +11 -11
- data/lib/openstudio-standards/btap/envelope.rb +5 -5
- data/lib/openstudio-standards/btap/hvac.rb +55 -11
- data/lib/openstudio-standards/btap/measures.rb +7 -7
- data/lib/openstudio-standards/btap/spaceloads.rb +4 -4
- data/lib/openstudio-standards/hvac_sizing/Siz.AirLoopHVAC.rb +105 -1
- data/lib/openstudio-standards/hvac_sizing/Siz.ControllerOutdoorAir.rb +2 -2
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2007/ashrae_90_1_2007.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +6 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.HeatExchangerAirToAirSensibleAndLatent.rb +9 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.rb +3 -1
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +22 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanConstantVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanOnOff.rb +33 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +32 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerAirToAirSensibleAndLatent.rb +9 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.elevators.rb +25 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +35 -0
- data/lib/openstudio-standards/prototypes/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.hvac_systems.rb +11 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Hospital.rb +17 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeHotel.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOffice.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.LargeOfficeDetailed.rb +22 -3
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOffice.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.MediumOfficeDetailed.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.Outpatient.rb +107 -5
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.PrimarySchool.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.RetailStandalone.rb +3 -0
- data/lib/openstudio-standards/prototypes/common/buildings/Prototype.SecondarySchool.rb +9 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.AirTerminalSingleDuctVAVReheat.rb +0 -8
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilCoolingDXTwoSpeed.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.CoilHeatingDXSingleSpeed.rb +2 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.HeatExchangerAirToAirSensibleAndLatent.rb +15 -4
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.exterior_lights.rb +2 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.Model.rb +45 -5
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.ServiceWaterHeating.rb +1 -1
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.SizingSystem.rb +21 -2
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.hvac_systems.rb +251 -364
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.radiant_system_controls.rb +4 -0
- data/lib/openstudio-standards/prototypes/common/objects/Prototype.refrigeration.rb +4 -5
- data/lib/openstudio-standards/refs/references.rb +4 -0
- data/lib/openstudio-standards/standards/Standards.AirLoopHVAC.rb +283 -97
- data/lib/openstudio-standards/standards/Standards.AirTerminalSingleDuctParallelPIUReheat.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.BuildingStory.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ChillerElectricEIR.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXSingleSpeed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.CoilCoolingDXTwoSpeed.rb +5 -5
- data/lib/openstudio-standards/standards/Standards.CoilDX.rb +3 -1
- data/lib/openstudio-standards/standards/Standards.CoilHeatingGasMultiStage.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Construction.rb +53 -45
- data/lib/openstudio-standards/standards/Standards.Fan.rb +10 -2
- data/lib/openstudio-standards/standards/Standards.FanVariableVolume.rb +4 -4
- data/lib/openstudio-standards/standards/Standards.HeatExchangerSensLat.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.Model.rb +39 -18
- data/lib/openstudio-standards/standards/Standards.PlanarSurface.rb +8 -8
- data/lib/openstudio-standards/standards/Standards.PlantLoop.rb +12 -12
- data/lib/openstudio-standards/standards/Standards.ScheduleConstant.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ScheduleRuleset.rb +2 -2
- data/lib/openstudio-standards/standards/Standards.Space.rb +190 -181
- data/lib/openstudio-standards/standards/Standards.SpaceType.rb +36 -59
- data/lib/openstudio-standards/standards/Standards.SubSurface.rb +3 -3
- data/lib/openstudio-standards/standards/Standards.Surface.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ThermalZone.rb +16 -12
- data/lib/openstudio-standards/standards/Standards.WaterHeaterMixed.rb +1 -1
- data/lib/openstudio-standards/standards/Standards.ZoneHVACComponent.rb +16 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/ashrae_90_1_2004.AirLoopHVAC.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/comstock_ashrae_90_1_2004/data/comstock_ashrae_90_1_2004.spc_typ.json +1354 -1075
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.construction_properties.json +557 -17
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.economizers.json +28 -28
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2004/data/ashrae_90_1_2004.spc_typ.json +233 -6
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/comstock_ashrae_90_1_2007/data/comstock_ashrae_90_1_2007.spc_typ.json +1356 -1077
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.economizers.json +28 -28
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2007/data/ashrae_90_1_2007.spc_typ.json +241 -14
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC.rb +0 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Space.rb +12 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/comstock_ashrae_90_1_2010/data/comstock_ashrae_90_1_2010.spc_typ.json +1367 -1087
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2010/data/ashrae_90_1_2010.spc_typ.json +233 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.AirLoopHVAC.rb +20 -27
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.Space.rb +8 -3
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/comstock_ashrae_90_1_2013/data/comstock_ashrae_90_1_2013.spc_typ.json +1432 -1138
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.construction_properties.json +480 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.ground_temperatures.json +36 -36
- data/lib/openstudio-standards/standards/ashrae_90_1/ashrae_90_1_2013/data/ashrae_90_1_2013.spc_typ.json +241 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.climate_zone_sets.json +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.climate_zones.json +39 -15
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.constructions.json +489 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.curves.json +250 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.fans.json +12 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.materials.json +1920 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/data/ashrae_90_1.schedules.json +5265 -9
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/comstock_doe_ref_1980_2004/data/comstock_doe_ref_1980_2004.spc_typ.json +2441 -1925
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.construction_properties.json +16658 -2578
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.spc_typ.json +212 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.rb +11 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/ashrae_90_1.schedules.json +159 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/data/comstock_doe_ref_pre_1980.spc_typ.json +2403 -1889
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.construction_properties.json +16664 -2584
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.spc_typ.json +209 -7
- data/lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb +11 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_properties.json +4113 -513
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.construction_sets.json +40 -40
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.elevators.json +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.ground_temperatures.json +650 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps.json +90 -2
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.heat_pumps_heating.json +25 -5
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.spc_typ.json +1909 -32
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/data/nrel_zne_ready_2017.water_heaters.json +8 -8
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirLoopHVAC.rb +147 -155
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.AirTerminalSingleDuctVAVReheat.rb +1 -1
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.HeatExchangerSensLat.rb +29 -10
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.Model.rb +4 -4
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.PlantLoop.rb +45 -73
- data/lib/openstudio-standards/standards/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.ZoneHVACComponent.rb +4 -72
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.boilers.json +20 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.chillers.json +400 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_properties.json +4444 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.construction_sets.json +391 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.economizers.json +536 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.elevators.json +36 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ext_ltg.json +169 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.ground_temperatures.json +650 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps.json +290 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_pumps_heating.json +164 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.heat_rejection.json +40 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.motors.json +274 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.prototype_inputs.json +704 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.refrigeration_compressors.json +22 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.spc_typ.json +6424 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.unitary_acs.json +142 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_heaters.json +72 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps.json +31 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/data/ze_aedg_multifamily.water_source_heat_pumps_heating.json +13 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirLoopHVAC.rb +829 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.AirTerminalSingleDuctVAVReheat.rb +24 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower.rb +19 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerSingleSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerTwoSpeed.rb +5 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTowerVariableSpeed.rb +16 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.FanVariableVolume.rb +37 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.HeatExchangerSensLat.rb +34 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Model.rb +80 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.PlantLoop.rb +68 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.Space.rb +146 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ThermalZone.rb +23 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.ZoneHVACComponent.rb +8 -0
- data/lib/openstudio-standards/standards/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.rb +16 -0
- data/lib/openstudio-standards/standards/deer/deer_1985/data/deer_1985.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.economizers.json +18 -0
- data/lib/openstudio-standards/standards/deer/deer_1996/data/deer_1996.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2003/data/deer_2003.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2007/data/deer_2007.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2011/data/deer_2011.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2014/data/deer_2014.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2015/data/deer_2015.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2017/data/deer_2017.heat_pumps_heating.json +1 -1
- data/lib/openstudio-standards/standards/deer/deer_2020/data/deer_2020.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2025/data/deer_2025.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2030/data/deer_2030.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2035/data/deer_2035.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2040/data/deer_2040.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2045/data/deer_2045.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2050/data/deer_2050.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2055/data/deer_2055.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2060/data/deer_2060.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2065/data/deer_2065.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2070/data/deer_2070.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_2075/data/deer_2075.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/deer/deer_pre_1975/data/deer_pre_1975.heat_pumps_heating.json +5 -5
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_1_multi_speed.rb +5 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_3_and_8_multi_speed.rb +5 -1
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_system_6.rb +5 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/hvac_systems.rb +8 -2
- data/lib/openstudio-standards/standards/necb/NECB2011/qaqc/necb_qaqc.rb +12 -12
- data/lib/openstudio-standards/version.rb +1 -1
- data/lib/openstudio-standards/weather/Weather.Model.rb +4 -0
- metadata +102 -18
- data/data/standards/OpenStudio_Standards-ashrae_90_1(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-ashrae_90_1.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-cbes(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-cbes.xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer-ALL-comstock(space_types).xlsx +0 -0
- data/data/standards/OpenStudio_Standards-deer.xlsx +0 -0
- data/data/standards/OpenStudio_Standards_LA100.xlsx +0 -0
- data/data/standards/junk/legacy_dd_results - Copy.csv +0 -960
- data/data/standards/junk/legacy_dd_results.csv +0 -960
- data/data/standards/junk/legacy_dd_results_new - Copy.csv +0 -960
- data/data/standards/junk/legacy_dd_results_new.csv +0 -960
- data/data/standards/junk/legacy_dd_results_original.csv +0 -960
- data/lib/openstudio-standards/standards/necb/NECB2011/newway.json +0 -8102
@@ -0,0 +1,142 @@
|
|
1
|
+
{
|
2
|
+
"unitary_acs": [
|
3
|
+
{
|
4
|
+
"template": "ZE AEDG Multifamily",
|
5
|
+
"cooling_type": "AirCooled",
|
6
|
+
"heating_type": "All Other",
|
7
|
+
"subcategory": "PTAC",
|
8
|
+
"minimum_capacity": 0.0,
|
9
|
+
"maximum_capacity": 9999999.0,
|
10
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
11
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
12
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
13
|
+
"minimum_energy_efficiency_ratio": null,
|
14
|
+
"minimum_integrated_part_load_value": null,
|
15
|
+
"minimum_integrated_energy_efficiency_ratio": null,
|
16
|
+
"ptac_eer_coefficient_1": 14.0,
|
17
|
+
"ptac_eer_coefficient_2": 0.3,
|
18
|
+
"minimum_scop": null,
|
19
|
+
"cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT",
|
20
|
+
"cool_cap_fflow": "DX Coil Cap-FF",
|
21
|
+
"cool_eir_ft": "PSZ-AC DX Coil EIR-FT",
|
22
|
+
"cool_eir_fflow": "Split DX Coil EIR-FF",
|
23
|
+
"cool_plf_fplr": "HPACCOOLPLFFPLR",
|
24
|
+
"notes": " From 90.1-2016 Table 6.8.1-4"
|
25
|
+
},
|
26
|
+
{
|
27
|
+
"template": "ZE AEDG Multifamily",
|
28
|
+
"cooling_type": "AirCooled",
|
29
|
+
"heating_type": "All Other",
|
30
|
+
"subcategory": "Single Package",
|
31
|
+
"minimum_capacity": 0.0,
|
32
|
+
"maximum_capacity": 9999999.0,
|
33
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
34
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
35
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
36
|
+
"minimum_energy_efficiency_ratio": 11.2,
|
37
|
+
"minimum_integrated_part_load_value": null,
|
38
|
+
"minimum_integrated_energy_efficiency_ratio": 12.9,
|
39
|
+
"ptac_eer_coefficient_1": null,
|
40
|
+
"ptac_eer_coefficient_2": null,
|
41
|
+
"minimum_scop": null,
|
42
|
+
"cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI",
|
43
|
+
"cool_cap_fflow": "CoilClgDXDblQRatio_fCFMRatio",
|
44
|
+
"cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI",
|
45
|
+
"cool_eir_fflow": "CoilClgDXDblEIRRatio_fCFMRatio",
|
46
|
+
"cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac",
|
47
|
+
"notes": " From 90.1-2016 Table 6.8.1-4"
|
48
|
+
},
|
49
|
+
{
|
50
|
+
"template": "ZE AEDG Multifamily",
|
51
|
+
"cooling_type": "AirCooled",
|
52
|
+
"heating_type": "All Other",
|
53
|
+
"subcategory": "Split System",
|
54
|
+
"minimum_capacity": 0.0,
|
55
|
+
"maximum_capacity": 9999999.0,
|
56
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
57
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
58
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
59
|
+
"minimum_energy_efficiency_ratio": 11.2,
|
60
|
+
"minimum_integrated_part_load_value": null,
|
61
|
+
"minimum_integrated_energy_efficiency_ratio": 12.9,
|
62
|
+
"ptac_eer_coefficient_1": null,
|
63
|
+
"ptac_eer_coefficient_2": null,
|
64
|
+
"minimum_scop": null,
|
65
|
+
"cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI",
|
66
|
+
"cool_cap_fflow": "CoilClgDXDblQRatio_fCFMRatio",
|
67
|
+
"cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI",
|
68
|
+
"cool_eir_fflow": "CoilClgDXDblEIRRatio_fCFMRatio",
|
69
|
+
"cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac",
|
70
|
+
"notes": " From 90.1-2016 Table 6.8.1-4"
|
71
|
+
},
|
72
|
+
{
|
73
|
+
"template": "ZE AEDG Multifamily",
|
74
|
+
"cooling_type": "AirCooled",
|
75
|
+
"heating_type": "Electric Resistance or None",
|
76
|
+
"subcategory": "PTAC",
|
77
|
+
"minimum_capacity": 0.0,
|
78
|
+
"maximum_capacity": 9999999.0,
|
79
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
80
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
81
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
82
|
+
"minimum_energy_efficiency_ratio": null,
|
83
|
+
"minimum_integrated_part_load_value": null,
|
84
|
+
"minimum_integrated_energy_efficiency_ratio": null,
|
85
|
+
"ptac_eer_coefficient_1": 14.0,
|
86
|
+
"ptac_eer_coefficient_2": 0.3,
|
87
|
+
"minimum_scop": null,
|
88
|
+
"cool_cap_ft": "PSZ-Fine Storage DX Coil Cap-FT",
|
89
|
+
"cool_cap_fflow": "DX Coil Cap-FF",
|
90
|
+
"cool_eir_ft": "PSZ-AC DX Coil EIR-FT",
|
91
|
+
"cool_eir_fflow": "Split DX Coil EIR-FF",
|
92
|
+
"cool_plf_fplr": "HPACCOOLPLFFPLR",
|
93
|
+
"notes": " From 90.1-2016 Table 6.8.1-4"
|
94
|
+
},
|
95
|
+
{
|
96
|
+
"template": "ZE AEDG Multifamily",
|
97
|
+
"cooling_type": "AirCooled",
|
98
|
+
"heating_type": "Electric Resistance or None",
|
99
|
+
"subcategory": "Single Package",
|
100
|
+
"minimum_capacity": 0.0,
|
101
|
+
"maximum_capacity": 9999999.0,
|
102
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
103
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
104
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
105
|
+
"minimum_energy_efficiency_ratio": 11.2,
|
106
|
+
"minimum_integrated_part_load_value": null,
|
107
|
+
"minimum_integrated_energy_efficiency_ratio": 12.9,
|
108
|
+
"ptac_eer_coefficient_1": null,
|
109
|
+
"ptac_eer_coefficient_2": null,
|
110
|
+
"minimum_scop": null,
|
111
|
+
"cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI",
|
112
|
+
"cool_cap_fflow": "CoilClgDXDblQRatio_fCFMRatio",
|
113
|
+
"cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI",
|
114
|
+
"cool_eir_fflow": "CoilClgDXDblEIRRatio_fCFMRatio",
|
115
|
+
"cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac",
|
116
|
+
"notes": " From 90.1-2016 Table 6.8.1-4"
|
117
|
+
},
|
118
|
+
{
|
119
|
+
"template": "ZE AEDG Multifamily",
|
120
|
+
"cooling_type": "AirCooled",
|
121
|
+
"heating_type": "Electric Resistance or None",
|
122
|
+
"subcategory": "Split System",
|
123
|
+
"minimum_capacity": 0.0,
|
124
|
+
"maximum_capacity": 9999999.0,
|
125
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
126
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
127
|
+
"minimum_seasonal_energy_efficiency_ratio": null,
|
128
|
+
"minimum_energy_efficiency_ratio": 11.2,
|
129
|
+
"minimum_integrated_part_load_value": null,
|
130
|
+
"minimum_integrated_energy_efficiency_ratio": 12.9,
|
131
|
+
"ptac_eer_coefficient_1": null,
|
132
|
+
"ptac_eer_coefficient_2": null,
|
133
|
+
"minimum_scop": null,
|
134
|
+
"cool_cap_ft": "CoilClgDXQRatio_fTwbToadbSI",
|
135
|
+
"cool_cap_fflow": "CoilClgDXDblQRatio_fCFMRatio",
|
136
|
+
"cool_eir_ft": "CoilClgDXEIRRatio_fTwbToadbSI",
|
137
|
+
"cool_eir_fflow": "CoilClgDXDblEIRRatio_fCFMRatio",
|
138
|
+
"cool_plf_fplr": "CoilClgDXEIRRatio_fQFrac",
|
139
|
+
"notes": " From 90.1-2016 Table 6.8.1-4"
|
140
|
+
}
|
141
|
+
]
|
142
|
+
}
|
@@ -0,0 +1,72 @@
|
|
1
|
+
{
|
2
|
+
"water_heaters": [
|
3
|
+
{
|
4
|
+
"template": "ZE AEDG Multifamily",
|
5
|
+
"fuel_type": "Electricity",
|
6
|
+
"minimum_capacity": 0.0,
|
7
|
+
"maximum_capacity": 40945.99,
|
8
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
9
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
10
|
+
"energy_factor_base": 0.97,
|
11
|
+
"energy_factor_volume_derate": "",
|
12
|
+
"standby_loss_base": null,
|
13
|
+
"standby_loss_capacity_allowance": null,
|
14
|
+
"standby_loss_volume_allowance": null,
|
15
|
+
"hourly_loss_base": null,
|
16
|
+
"hourly_loss_volume_allowance": null,
|
17
|
+
"thermal_efficiency": null,
|
18
|
+
"notes": "Code of Federal Regulations 10 CFR Part 430."
|
19
|
+
},
|
20
|
+
{
|
21
|
+
"template": "ZE AEDG Multifamily",
|
22
|
+
"fuel_type": "Electricity",
|
23
|
+
"minimum_capacity": 40946.0,
|
24
|
+
"maximum_capacity": 99999999.0,
|
25
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
26
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
27
|
+
"energy_factor_base": null,
|
28
|
+
"energy_factor_volume_derate": null,
|
29
|
+
"standby_loss_base": 20.0,
|
30
|
+
"standby_loss_capacity_allowance": null,
|
31
|
+
"standby_loss_volume_allowance": 35.0,
|
32
|
+
"hourly_loss_base": null,
|
33
|
+
"hourly_loss_volume_allowance": null,
|
34
|
+
"thermal_efficiency": null,
|
35
|
+
"notes": "From 90.1-2016 Table 7.8"
|
36
|
+
},
|
37
|
+
{
|
38
|
+
"template": "ZE AEDG Multifamily",
|
39
|
+
"fuel_type": "NaturalGas",
|
40
|
+
"minimum_capacity": 0.0,
|
41
|
+
"maximum_capacity": 74999.99,
|
42
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
43
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
44
|
+
"energy_factor_base": 0.67,
|
45
|
+
"energy_factor_volume_derate": "",
|
46
|
+
"standby_loss_base": null,
|
47
|
+
"standby_loss_capacity_allowance": null,
|
48
|
+
"standby_loss_volume_allowance": null,
|
49
|
+
"hourly_loss_base": null,
|
50
|
+
"hourly_loss_volume_allowance": null,
|
51
|
+
"thermal_efficiency": null,
|
52
|
+
"notes": "Code of Federal Regulations 10 CFR Part 430."
|
53
|
+
},
|
54
|
+
{
|
55
|
+
"template": "ZE AEDG Multifamily",
|
56
|
+
"fuel_type": "NaturalGas",
|
57
|
+
"minimum_capacity": 75000.0,
|
58
|
+
"maximum_capacity": 99999999.0,
|
59
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
60
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
61
|
+
"energy_factor_base": null,
|
62
|
+
"energy_factor_volume_derate": null,
|
63
|
+
"standby_loss_base": null,
|
64
|
+
"standby_loss_capacity_allowance": 799.0,
|
65
|
+
"standby_loss_volume_allowance": 16.6,
|
66
|
+
"hourly_loss_base": null,
|
67
|
+
"hourly_loss_volume_allowance": null,
|
68
|
+
"thermal_efficiency": 0.8,
|
69
|
+
"notes": "From 90.1-2016 Table 7.8"
|
70
|
+
}
|
71
|
+
]
|
72
|
+
}
|
@@ -0,0 +1,31 @@
|
|
1
|
+
{
|
2
|
+
"water_source_heat_pumps": [
|
3
|
+
{
|
4
|
+
"template": "ZE AEDG Multifamily",
|
5
|
+
"minimum_capacity": 0.0,
|
6
|
+
"maximum_capacity": 16999.0,
|
7
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
8
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
9
|
+
"minimum_full_load_efficiency": 18.2,
|
10
|
+
"notes": "From ZE AEDG Multifamily Committee"
|
11
|
+
},
|
12
|
+
{
|
13
|
+
"template": "ZE AEDG Multifamily",
|
14
|
+
"minimum_capacity": 17000.0,
|
15
|
+
"maximum_capacity": 64999.0,
|
16
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
17
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
18
|
+
"minimum_full_load_efficiency": 18.2,
|
19
|
+
"notes": "From ZE AEDG Multifamily Committee"
|
20
|
+
},
|
21
|
+
{
|
22
|
+
"template": "ZE AEDG Multifamily",
|
23
|
+
"minimum_capacity": 65000.0,
|
24
|
+
"maximum_capacity": 134999.0,
|
25
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
26
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
27
|
+
"minimum_full_load_efficiency": 18.2,
|
28
|
+
"notes": "From ZE AEDG Multifamily Committee"
|
29
|
+
}
|
30
|
+
]
|
31
|
+
}
|
@@ -0,0 +1,13 @@
|
|
1
|
+
{
|
2
|
+
"water_source_heat_pumps_heating": [
|
3
|
+
{
|
4
|
+
"template": "ZE AEDG Multifamily",
|
5
|
+
"minimum_capacity": 0.0,
|
6
|
+
"maximum_capacity": 9999999.0,
|
7
|
+
"start_date": "1919-09-09T00:00:00+00:00",
|
8
|
+
"end_date": "2999-09-09T00:00:00+00:00",
|
9
|
+
"minimum_coefficient_of_performance_heating": 5.4,
|
10
|
+
"notes": "From ZE AEDG Multifamily Committee"
|
11
|
+
}
|
12
|
+
]
|
13
|
+
}
|
@@ -0,0 +1,829 @@
|
|
1
|
+
class ZEAEDGMultifamily < ASHRAE901
|
2
|
+
# @!group AirLoopHVAC
|
3
|
+
|
4
|
+
# Same as 90.1-2013
|
5
|
+
# Determine the limits for the type of economizer present on the AirLoopHVAC, if any.
|
6
|
+
# @return [Array<Double>] [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
|
7
|
+
def air_loop_hvac_economizer_limits(air_loop_hvac, climate_zone)
|
8
|
+
drybulb_limit_f = nil
|
9
|
+
enthalpy_limit_btu_per_lb = nil
|
10
|
+
dewpoint_limit_f = nil
|
11
|
+
|
12
|
+
# Get the OA system and OA controller
|
13
|
+
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
14
|
+
if oa_sys.is_initialized
|
15
|
+
oa_sys = oa_sys.get
|
16
|
+
else
|
17
|
+
return [nil, nil, nil] # No OA system
|
18
|
+
end
|
19
|
+
oa_control = oa_sys.getControllerOutdoorAir
|
20
|
+
economizer_type = oa_control.getEconomizerControlType
|
21
|
+
oa_control.resetEconomizerMinimumLimitDryBulbTemperature
|
22
|
+
|
23
|
+
case economizer_type
|
24
|
+
when 'NoEconomizer'
|
25
|
+
OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name} no economizer")
|
26
|
+
return [nil, nil, nil]
|
27
|
+
when 'FixedDryBulb'
|
28
|
+
case climate_zone
|
29
|
+
when 'ASHRAE 169-2006-0B',
|
30
|
+
'ASHRAE 169-2006-1B',
|
31
|
+
'ASHRAE 169-2006-2B',
|
32
|
+
'ASHRAE 169-2006-3B',
|
33
|
+
'ASHRAE 169-2006-3C',
|
34
|
+
'ASHRAE 169-2006-4B',
|
35
|
+
'ASHRAE 169-2006-4C',
|
36
|
+
'ASHRAE 169-2006-5B',
|
37
|
+
'ASHRAE 169-2006-5C',
|
38
|
+
'ASHRAE 169-2006-6B',
|
39
|
+
'ASHRAE 169-2006-7A',
|
40
|
+
'ASHRAE 169-2006-7B',
|
41
|
+
'ASHRAE 169-2006-8A',
|
42
|
+
'ASHRAE 169-2006-8B',
|
43
|
+
'ASHRAE 169-2013-0B',
|
44
|
+
'ASHRAE 169-2013-1B',
|
45
|
+
'ASHRAE 169-2013-2B',
|
46
|
+
'ASHRAE 169-2013-3B',
|
47
|
+
'ASHRAE 169-2013-3C',
|
48
|
+
'ASHRAE 169-2013-4B',
|
49
|
+
'ASHRAE 169-2013-4C',
|
50
|
+
'ASHRAE 169-2013-5B',
|
51
|
+
'ASHRAE 169-2013-5C',
|
52
|
+
'ASHRAE 169-2013-6B',
|
53
|
+
'ASHRAE 169-2013-7A',
|
54
|
+
'ASHRAE 169-2013-7B',
|
55
|
+
'ASHRAE 169-2013-8A',
|
56
|
+
'ASHRAE 169-2013-8B'
|
57
|
+
drybulb_limit_f = 75.0
|
58
|
+
when 'ASHRAE 169-2006-5A',
|
59
|
+
'ASHRAE 169-2006-6A',
|
60
|
+
'ASHRAE 169-2013-5A',
|
61
|
+
'ASHRAE 169-2013-6A'
|
62
|
+
drybulb_limit_f = 70.0
|
63
|
+
end
|
64
|
+
when 'FixedEnthalpy'
|
65
|
+
enthalpy_limit_btu_per_lb = 28.0
|
66
|
+
when 'FixedDewPointAndDryBulb'
|
67
|
+
drybulb_limit_f = 75.0
|
68
|
+
dewpoint_limit_f = 55.0
|
69
|
+
when 'DifferentialDryBulb', 'DifferentialEnthalpy'
|
70
|
+
OpenStudio.logFree(OpenStudio::Debug, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Economizer type = #{economizer_type}, no limits defined.")
|
71
|
+
end
|
72
|
+
|
73
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Economizer type = #{economizer_type}, limits [#{drybulb_limit_f},#{enthalpy_limit_btu_per_lb},#{dewpoint_limit_f}]")
|
74
|
+
|
75
|
+
return [drybulb_limit_f, enthalpy_limit_btu_per_lb, dewpoint_limit_f]
|
76
|
+
end
|
77
|
+
|
78
|
+
# Same as 90.1-2013
|
79
|
+
# Determine if the system economizer must be integrated or not.
|
80
|
+
# All economizers must be integrated in NREL ZNE Ready 2017
|
81
|
+
def air_loop_hvac_integrated_economizer_required?(air_loop_hvac, climate_zone)
|
82
|
+
integrated_economizer_required = true
|
83
|
+
return integrated_economizer_required
|
84
|
+
end
|
85
|
+
|
86
|
+
# Same as 90.1-2013
|
87
|
+
# Check the economizer type currently specified in the ControllerOutdoorAir object on this air loop
|
88
|
+
# is acceptable per the standard.
|
89
|
+
#
|
90
|
+
# @param (see #economizer_required?)
|
91
|
+
# @return [Bool] Returns true if allowable, if the system has no economizer or no OA system.
|
92
|
+
# Returns false if the economizer type is not allowable.
|
93
|
+
def air_loop_hvac_economizer_type_allowable?(air_loop_hvac, climate_zone)
|
94
|
+
# EnergyPlus economizer types
|
95
|
+
# 'NoEconomizer'
|
96
|
+
# 'FixedDryBulb'
|
97
|
+
# 'FixedEnthalpy'
|
98
|
+
# 'DifferentialDryBulb'
|
99
|
+
# 'DifferentialEnthalpy'
|
100
|
+
# 'FixedDewPointAndDryBulb'
|
101
|
+
# 'ElectronicEnthalpy'
|
102
|
+
# 'DifferentialDryBulbAndEnthalpy'
|
103
|
+
|
104
|
+
# Get the OA system and OA controller
|
105
|
+
oa_sys = air_loop_hvac.airLoopHVACOutdoorAirSystem
|
106
|
+
if oa_sys.is_initialized
|
107
|
+
oa_sys = oa_sys.get
|
108
|
+
else
|
109
|
+
return true # No OA system
|
110
|
+
end
|
111
|
+
oa_control = oa_sys.getControllerOutdoorAir
|
112
|
+
economizer_type = oa_control.getEconomizerControlType
|
113
|
+
|
114
|
+
# Return true if no economizer is present
|
115
|
+
if economizer_type == 'NoEconomizer'
|
116
|
+
return true
|
117
|
+
end
|
118
|
+
|
119
|
+
# Determine the prohibited types
|
120
|
+
prohibited_types = []
|
121
|
+
case climate_zone
|
122
|
+
when 'ASHRAE 169-2006-0B',
|
123
|
+
'ASHRAE 169-2006-1B',
|
124
|
+
'ASHRAE 169-2006-2B',
|
125
|
+
'ASHRAE 169-2006-3B',
|
126
|
+
'ASHRAE 169-2006-3C',
|
127
|
+
'ASHRAE 169-2006-4B',
|
128
|
+
'ASHRAE 169-2006-4C',
|
129
|
+
'ASHRAE 169-2006-5B',
|
130
|
+
'ASHRAE 169-2006-6B',
|
131
|
+
'ASHRAE 169-2006-7A',
|
132
|
+
'ASHRAE 169-2006-7B',
|
133
|
+
'ASHRAE 169-2006-8A',
|
134
|
+
'ASHRAE 169-2006-8B',
|
135
|
+
'ASHRAE 169-2013-0B',
|
136
|
+
'ASHRAE 169-2013-1B',
|
137
|
+
'ASHRAE 169-2013-2B',
|
138
|
+
'ASHRAE 169-2013-3B',
|
139
|
+
'ASHRAE 169-2013-3C',
|
140
|
+
'ASHRAE 169-2013-4B',
|
141
|
+
'ASHRAE 169-2013-4C',
|
142
|
+
'ASHRAE 169-2013-5B',
|
143
|
+
'ASHRAE 169-2013-6B',
|
144
|
+
'ASHRAE 169-2013-7A',
|
145
|
+
'ASHRAE 169-2013-7B',
|
146
|
+
'ASHRAE 169-2013-8A',
|
147
|
+
'ASHRAE 169-2013-8B'
|
148
|
+
prohibited_types = ['FixedEnthalpy']
|
149
|
+
when 'ASHRAE 169-2006-0A',
|
150
|
+
'ASHRAE 169-2006-1A',
|
151
|
+
'ASHRAE 169-2006-2A',
|
152
|
+
'ASHRAE 169-2006-3A',
|
153
|
+
'ASHRAE 169-2006-4A',
|
154
|
+
'ASHRAE 169-2013-0A',
|
155
|
+
'ASHRAE 169-2013-1A',
|
156
|
+
'ASHRAE 169-2013-2A',
|
157
|
+
'ASHRAE 169-2013-3A',
|
158
|
+
'ASHRAE 169-2013-4A'
|
159
|
+
prohibited_types = ['FixedDryBulb', 'DifferentialDryBulb']
|
160
|
+
when 'ASHRAE 169-2006-5A',
|
161
|
+
'ASHRAE 169-2006-6A',
|
162
|
+
'ASHRAE 169-2013-5A',
|
163
|
+
'ASHRAE 169-2013-6A'
|
164
|
+
prohibited_types = []
|
165
|
+
end
|
166
|
+
|
167
|
+
# Check if the specified type is allowed
|
168
|
+
economizer_type_allowed = true
|
169
|
+
if prohibited_types.include?(economizer_type)
|
170
|
+
economizer_type_allowed = false
|
171
|
+
end
|
172
|
+
|
173
|
+
return economizer_type_allowed
|
174
|
+
end
|
175
|
+
|
176
|
+
# Same as 90.1-2013
|
177
|
+
# Determine if multizone vav optimization is required.
|
178
|
+
#
|
179
|
+
# @param (see #economizer_required?)
|
180
|
+
# @return [Bool] Returns true if required, false if not.
|
181
|
+
# @todo Add exception logic for
|
182
|
+
# systems with AIA healthcare ventilation requirements
|
183
|
+
# dual duct systems
|
184
|
+
def air_loop_hvac_multizone_vav_optimization_required?(air_loop_hvac, climate_zone)
|
185
|
+
multizone_opt_required = false
|
186
|
+
|
187
|
+
# Not required for systems with fan-powered terminals
|
188
|
+
num_fan_powered_terminals = 0
|
189
|
+
air_loop_hvac.demandComponents.each do |comp|
|
190
|
+
if comp.to_AirTerminalSingleDuctParallelPIUReheat.is_initialized || comp.to_AirTerminalSingleDuctSeriesPIUReheat.is_initialized
|
191
|
+
num_fan_powered_terminals += 1
|
192
|
+
end
|
193
|
+
end
|
194
|
+
if num_fan_powered_terminals > 0
|
195
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, multizone vav optimization is not required because the system has #{num_fan_powered_terminals} fan-powered terminals.")
|
196
|
+
return multizone_opt_required
|
197
|
+
end
|
198
|
+
|
199
|
+
# Not required for systems that require an ERV
|
200
|
+
if air_loop_hvac_energy_recovery?(air_loop_hvac)
|
201
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: multizone vav optimization is not required because the system has Energy Recovery.")
|
202
|
+
return multizone_opt_required
|
203
|
+
end
|
204
|
+
|
205
|
+
# Get the OA intake
|
206
|
+
controller_oa = nil
|
207
|
+
controller_mv = nil
|
208
|
+
oa_system = nil
|
209
|
+
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
210
|
+
oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
|
211
|
+
controller_oa = oa_system.getControllerOutdoorAir
|
212
|
+
controller_mv = controller_oa.controllerMechanicalVentilation
|
213
|
+
else
|
214
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, multizone optimization is not applicable because system has no OA intake.")
|
215
|
+
return multizone_opt_required
|
216
|
+
end
|
217
|
+
|
218
|
+
# Get the AHU design supply air flow rate
|
219
|
+
dsn_flow_m3_per_s = nil
|
220
|
+
if air_loop_hvac.designSupplyAirFlowRate.is_initialized
|
221
|
+
dsn_flow_m3_per_s = air_loop_hvac.designSupplyAirFlowRate.get
|
222
|
+
elsif air_loop_hvac.autosizedDesignSupplyAirFlowRate.is_initialized
|
223
|
+
dsn_flow_m3_per_s = air_loop_hvac.autosizedDesignSupplyAirFlowRate.get
|
224
|
+
else
|
225
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name} design supply air flow rate is not available, cannot apply efficiency standard.")
|
226
|
+
return multizone_opt_required
|
227
|
+
end
|
228
|
+
dsn_flow_cfm = OpenStudio.convert(dsn_flow_m3_per_s, 'm^3/s', 'cfm').get
|
229
|
+
|
230
|
+
# Get the minimum OA flow rate
|
231
|
+
min_oa_flow_m3_per_s = nil
|
232
|
+
if controller_oa.minimumOutdoorAirFlowRate.is_initialized
|
233
|
+
min_oa_flow_m3_per_s = controller_oa.minimumOutdoorAirFlowRate.get
|
234
|
+
elsif controller_oa.autosizedMinimumOutdoorAirFlowRate.is_initialized
|
235
|
+
min_oa_flow_m3_per_s = controller_oa.autosizedMinimumOutdoorAirFlowRate.get
|
236
|
+
else
|
237
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{controller_oa.name}: minimum OA flow rate is not available, cannot apply efficiency standard.")
|
238
|
+
return multizone_opt_required
|
239
|
+
end
|
240
|
+
min_oa_flow_cfm = OpenStudio.convert(min_oa_flow_m3_per_s, 'm^3/s', 'cfm').get
|
241
|
+
|
242
|
+
# Calculate the percent OA at design airflow
|
243
|
+
pct_oa = min_oa_flow_m3_per_s / dsn_flow_m3_per_s
|
244
|
+
|
245
|
+
# Not required for systems where
|
246
|
+
# exhaust is more than 70% of the total OA intake.
|
247
|
+
if pct_oa > 0.7
|
248
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{controller_oa.name}: multizone optimization is not applicable because system is more than 70% OA.")
|
249
|
+
return multizone_opt_required
|
250
|
+
end
|
251
|
+
|
252
|
+
# TODO: Not required for dual-duct systems
|
253
|
+
# if self.isDualDuct
|
254
|
+
# OpenStudio::logFree(OpenStudio::Info, "openstudio.standards.AirLoopHVAC", "For #{controller_oa.name}: multizone optimization is not applicable because it is a dual duct system")
|
255
|
+
# return multizone_opt_required
|
256
|
+
# end
|
257
|
+
|
258
|
+
# If here, multizone vav optimization is required
|
259
|
+
multizone_opt_required = true
|
260
|
+
|
261
|
+
return multizone_opt_required
|
262
|
+
end
|
263
|
+
|
264
|
+
# Determines the OA flow rates above which an economizer is required.
|
265
|
+
# Two separate rates, one for systems with an economizer and another
|
266
|
+
# for systems without.
|
267
|
+
# are zero for both types.
|
268
|
+
# @return [Array<Double>] [min_oa_without_economizer_cfm, min_oa_with_economizer_cfm]
|
269
|
+
def air_loop_hvac_demand_control_ventilation_limits(air_loop_hvac)
|
270
|
+
min_oa_without_economizer_cfm = 1500.0 # half the 90.1-2013 requirement
|
271
|
+
min_oa_with_economizer_cfm = 375.0 # half the 90.1-2013 requirement
|
272
|
+
return [min_oa_without_economizer_cfm, min_oa_with_economizer_cfm]
|
273
|
+
end
|
274
|
+
|
275
|
+
# Determine if the standard has an exception for demand control ventilation when an energy recovery device is present.
|
276
|
+
# DCV and an ERV may be used in conjunction.
|
277
|
+
def air_loop_hvac_dcv_required_when_erv(air_loop_hvac)
|
278
|
+
dcv_required_when_erv_present = true
|
279
|
+
return dcv_required_when_erv_present
|
280
|
+
end
|
281
|
+
|
282
|
+
# Same as 90.1-2013
|
283
|
+
# Determine the air flow and number of story limits for whether motorized OA damper is required.
|
284
|
+
# @return [Array<Double>] [minimum_oa_flow_cfm, maximum_stories]
|
285
|
+
def air_loop_hvac_motorized_oa_damper_limits(air_loop_hvac, climate_zone)
|
286
|
+
case climate_zone
|
287
|
+
when 'ASHRAE 169-2006-0A',
|
288
|
+
'ASHRAE 169-2006-0B',
|
289
|
+
'ASHRAE 169-2006-1A',
|
290
|
+
'ASHRAE 169-2006-1B',
|
291
|
+
'ASHRAE 169-2006-2A',
|
292
|
+
'ASHRAE 169-2006-2B',
|
293
|
+
'ASHRAE 169-2006-3A',
|
294
|
+
'ASHRAE 169-2006-3B',
|
295
|
+
'ASHRAE 169-2006-3C',
|
296
|
+
'ASHRAE 169-2013-0A',
|
297
|
+
'ASHRAE 169-2013-0B',
|
298
|
+
'ASHRAE 169-2013-1A',
|
299
|
+
'ASHRAE 169-2013-1B',
|
300
|
+
'ASHRAE 169-2013-2A',
|
301
|
+
'ASHRAE 169-2013-2B',
|
302
|
+
'ASHRAE 169-2013-3A',
|
303
|
+
'ASHRAE 169-2013-3B',
|
304
|
+
'ASHRAE 169-2013-3C'
|
305
|
+
minimum_oa_flow_cfm = 0
|
306
|
+
maximum_stories = 999 # Any number of stories
|
307
|
+
else
|
308
|
+
minimum_oa_flow_cfm = 0
|
309
|
+
maximum_stories = 0
|
310
|
+
end
|
311
|
+
|
312
|
+
return [minimum_oa_flow_cfm, maximum_stories]
|
313
|
+
end
|
314
|
+
|
315
|
+
# Same as 90.1-2013
|
316
|
+
# Determine the number of stages that should be used as controls for single zone DX systems.
|
317
|
+
# 90.1-2013 depends on the cooling capacity of the system.
|
318
|
+
#
|
319
|
+
# @return [Integer] the number of stages: 0, 1, 2
|
320
|
+
def air_loop_hvac_single_zone_controls_num_stages(air_loop_hvac, climate_zone)
|
321
|
+
min_clg_cap_btu_per_hr = 65_000
|
322
|
+
clg_cap_btu_per_hr = OpenStudio.convert(air_loop_hvac_total_cooling_capacity(air_loop_hvac), 'W', 'Btu/hr').get
|
323
|
+
if clg_cap_btu_per_hr >= min_clg_cap_btu_per_hr
|
324
|
+
num_stages = 2
|
325
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: two-stage control is required since cooling capacity of #{clg_cap_btu_per_hr.round} Btu/hr exceeds the minimum of #{min_clg_cap_btu_per_hr.round} Btu/hr .")
|
326
|
+
else
|
327
|
+
num_stages = 1
|
328
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: two-stage control is not required since cooling capacity of #{clg_cap_btu_per_hr.round} Btu/hr is less than the minimum of #{min_clg_cap_btu_per_hr.round} Btu/hr .")
|
329
|
+
end
|
330
|
+
|
331
|
+
return num_stages
|
332
|
+
end
|
333
|
+
|
334
|
+
# Same as 90.1-2013
|
335
|
+
# Determine if the system required supply air temperature (SAT) reset.
|
336
|
+
# For 90.1-2013, SAT reset requirements are based on climate zone.
|
337
|
+
#
|
338
|
+
# @param (see #economizer_required?)
|
339
|
+
# @return [Bool] Returns true if required, false if not.
|
340
|
+
def air_loop_hvac_supply_air_temperature_reset_required?(air_loop_hvac, climate_zone)
|
341
|
+
is_sat_reset_required = false
|
342
|
+
|
343
|
+
# Only required for multizone VAV systems
|
344
|
+
unless air_loop_hvac_multizone_vav_system?(air_loop_hvac)
|
345
|
+
return is_sat_reset_required
|
346
|
+
end
|
347
|
+
|
348
|
+
case climate_zone
|
349
|
+
when 'ASHRAE 169-2006-0A',
|
350
|
+
'ASHRAE 169-2006-1A',
|
351
|
+
'ASHRAE 169-2006-2A',
|
352
|
+
'ASHRAE 169-2006-3A',
|
353
|
+
'ASHRAE 169-2013-0A',
|
354
|
+
'ASHRAE 169-2013-1A',
|
355
|
+
'ASHRAE 169-2013-2A',
|
356
|
+
'ASHRAE 169-2013-3A'
|
357
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is not required per 6.5.3.4 Exception 1, the system is located in climate zone #{climate_zone}.")
|
358
|
+
return is_sat_reset_required
|
359
|
+
when 'ASHRAE 169-2006-0B',
|
360
|
+
'ASHRAE 169-2006-1B',
|
361
|
+
'ASHRAE 169-2006-2B',
|
362
|
+
'ASHRAE 169-2006-3B',
|
363
|
+
'ASHRAE 169-2006-3C',
|
364
|
+
'ASHRAE 169-2006-4A',
|
365
|
+
'ASHRAE 169-2006-4B',
|
366
|
+
'ASHRAE 169-2006-4C',
|
367
|
+
'ASHRAE 169-2006-5A',
|
368
|
+
'ASHRAE 169-2006-5B',
|
369
|
+
'ASHRAE 169-2006-5C',
|
370
|
+
'ASHRAE 169-2006-6A',
|
371
|
+
'ASHRAE 169-2006-6B',
|
372
|
+
'ASHRAE 169-2006-7A',
|
373
|
+
'ASHRAE 169-2006-7B',
|
374
|
+
'ASHRAE 169-2006-8A',
|
375
|
+
'ASHRAE 169-2006-8B',
|
376
|
+
'ASHRAE 169-2013-0B',
|
377
|
+
'ASHRAE 169-2013-1B',
|
378
|
+
'ASHRAE 169-2013-2B',
|
379
|
+
'ASHRAE 169-2013-3B',
|
380
|
+
'ASHRAE 169-2013-3C',
|
381
|
+
'ASHRAE 169-2013-4A',
|
382
|
+
'ASHRAE 169-2013-4B',
|
383
|
+
'ASHRAE 169-2013-4C',
|
384
|
+
'ASHRAE 169-2013-5A',
|
385
|
+
'ASHRAE 169-2013-5B',
|
386
|
+
'ASHRAE 169-2013-5C',
|
387
|
+
'ASHRAE 169-2013-6A',
|
388
|
+
'ASHRAE 169-2013-6B',
|
389
|
+
'ASHRAE 169-2013-7A',
|
390
|
+
'ASHRAE 169-2013-7B',
|
391
|
+
'ASHRAE 169-2013-8A',
|
392
|
+
'ASHRAE 169-2013-8B'
|
393
|
+
is_sat_reset_required = true
|
394
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: Supply air temperature reset is required.")
|
395
|
+
return is_sat_reset_required
|
396
|
+
end
|
397
|
+
end
|
398
|
+
|
399
|
+
# Default occupancy fraction threshold for determining if the spaces on the air loop are occupied
|
400
|
+
def air_loop_hvac_unoccupied_threshold
|
401
|
+
return 0.05
|
402
|
+
end
|
403
|
+
|
404
|
+
# Same as Standards method but with no DCV exception
|
405
|
+
# Check if ERV is required on this airloop.
|
406
|
+
#
|
407
|
+
# @return [Bool] Returns true if required, false if not.
|
408
|
+
def air_loop_hvac_energy_recovery_ventilator_required?(air_loop_hvac, climate_zone)
|
409
|
+
|
410
|
+
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
411
|
+
oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
|
412
|
+
controller_oa = oa_system.getControllerOutdoorAir
|
413
|
+
controller_mv = controller_oa.controllerMechanicalVentilation
|
414
|
+
else
|
415
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, ERV not applicable because it has no OA intake.")
|
416
|
+
return false
|
417
|
+
end
|
418
|
+
|
419
|
+
# Get the AHU design supply air flow rate
|
420
|
+
dsn_flow_m3_per_s = nil
|
421
|
+
if air_loop_hvac.designSupplyAirFlowRate.is_initialized
|
422
|
+
dsn_flow_m3_per_s = air_loop_hvac.designSupplyAirFlowRate.get
|
423
|
+
elsif air_loop_hvac.autosizedDesignSupplyAirFlowRate.is_initialized
|
424
|
+
dsn_flow_m3_per_s = air_loop_hvac.autosizedDesignSupplyAirFlowRate.get
|
425
|
+
else
|
426
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name} design supply air flow rate is not available, cannot apply efficiency standard.")
|
427
|
+
return false
|
428
|
+
end
|
429
|
+
dsn_flow_cfm = OpenStudio.convert(dsn_flow_m3_per_s, 'm^3/s', 'cfm').get
|
430
|
+
|
431
|
+
# Get the minimum OA flow rate
|
432
|
+
min_oa_flow_m3_per_s = nil
|
433
|
+
if controller_oa.minimumOutdoorAirFlowRate.is_initialized
|
434
|
+
min_oa_flow_m3_per_s = controller_oa.minimumOutdoorAirFlowRate.get
|
435
|
+
elsif controller_oa.autosizedMinimumOutdoorAirFlowRate.is_initialized
|
436
|
+
min_oa_flow_m3_per_s = controller_oa.autosizedMinimumOutdoorAirFlowRate.get
|
437
|
+
else
|
438
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{controller_oa.name}: minimum OA flow rate is not available, cannot apply efficiency standard.")
|
439
|
+
return false
|
440
|
+
end
|
441
|
+
min_oa_flow_cfm = OpenStudio.convert(min_oa_flow_m3_per_s, 'm^3/s', 'cfm').get
|
442
|
+
|
443
|
+
# Calculate the percent OA at design airflow
|
444
|
+
pct_oa = min_oa_flow_m3_per_s / dsn_flow_m3_per_s
|
445
|
+
|
446
|
+
# Determine the airflow limit
|
447
|
+
erv_cfm = air_loop_hvac_energy_recovery_ventilator_flow_limit(air_loop_hvac, climate_zone, pct_oa)
|
448
|
+
|
449
|
+
# Determine if an ERV is required
|
450
|
+
if erv_cfm.nil?
|
451
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, ERV not required based on #{(pct_oa * 100).round}% OA flow, design supply air flow of #{dsn_flow_cfm.round}cfm, and climate zone #{climate_zone}.")
|
452
|
+
erv_required = false
|
453
|
+
elsif dsn_flow_cfm < erv_cfm
|
454
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, ERV not required based on #{(pct_oa * 100).round}% OA flow, design supply air flow of #{dsn_flow_cfm.round}cfm, and climate zone #{climate_zone}. Does not exceed minimum flow requirement of #{erv_cfm}cfm.")
|
455
|
+
erv_required = false
|
456
|
+
else
|
457
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}, ERV required based on #{(pct_oa * 100).round}% OA flow, design supply air flow of #{dsn_flow_cfm.round}cfm, and climate zone #{climate_zone}. Exceeds minimum flow requirement of #{erv_cfm}cfm.")
|
458
|
+
erv_required = true
|
459
|
+
end
|
460
|
+
|
461
|
+
return erv_required
|
462
|
+
end
|
463
|
+
|
464
|
+
# Same as 90.1-2016
|
465
|
+
# Determine the airflow limits that govern whether or not an ERV is required.
|
466
|
+
# Based on climate zone and % OA, plus the number of operating hours the system has.
|
467
|
+
# @return [Double] the flow rate above which an ERV is required.
|
468
|
+
# if nil, ERV is never required.
|
469
|
+
def air_loop_hvac_energy_recovery_ventilator_flow_limit(air_loop_hvac, climate_zone, pct_oa)
|
470
|
+
# Calculate the number of system operating hours
|
471
|
+
# based on the availability schedule.
|
472
|
+
ann_op_hrs = 0.0
|
473
|
+
avail_sch = air_loop_hvac.availabilitySchedule
|
474
|
+
if avail_sch == air_loop_hvac.model.alwaysOnDiscreteSchedule
|
475
|
+
ann_op_hrs = 8760.0
|
476
|
+
elsif avail_sch.to_ScheduleRuleset.is_initialized
|
477
|
+
avail_sch = avail_sch.to_ScheduleRuleset.get
|
478
|
+
ann_op_hrs = schedule_ruleset_annual_hours_above_value(avail_sch, 0.0)
|
479
|
+
else
|
480
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.AirLoopHVAC', "For #{air_loop_hvac.name}: could not determine annual operating hours. Assuming less than 8,000 for ERV determination.")
|
481
|
+
end
|
482
|
+
|
483
|
+
if ann_op_hrs < 8000.0
|
484
|
+
# Table 6.5.6.1-1, less than 8000 hrs
|
485
|
+
case climate_zone
|
486
|
+
when 'ASHRAE 169-2006-3B',
|
487
|
+
'ASHRAE 169-2006-3C',
|
488
|
+
'ASHRAE 169-2006-4B',
|
489
|
+
'ASHRAE 169-2006-4C',
|
490
|
+
'ASHRAE 169-2006-5B',
|
491
|
+
'ASHRAE 169-2013-3B',
|
492
|
+
'ASHRAE 169-2013-3C',
|
493
|
+
'ASHRAE 169-2013-4B',
|
494
|
+
'ASHRAE 169-2013-4C',
|
495
|
+
'ASHRAE 169-2013-5B'
|
496
|
+
if pct_oa < 0.1
|
497
|
+
erv_cfm = nil
|
498
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
499
|
+
erv_cfm = nil
|
500
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
501
|
+
erv_cfm = nil
|
502
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
503
|
+
erv_cfm = nil
|
504
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
505
|
+
erv_cfm = nil
|
506
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
507
|
+
erv_cfm = nil
|
508
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
509
|
+
erv_cfm = nil
|
510
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
511
|
+
erv_cfm = nil
|
512
|
+
elsif pct_oa >= 0.8
|
513
|
+
erv_cfm = nil
|
514
|
+
end
|
515
|
+
when 'ASHRAE 169-2006-0B',
|
516
|
+
'ASHRAE 169-2006-1B',
|
517
|
+
'ASHRAE 169-2006-2B',
|
518
|
+
'ASHRAE 169-2006-5C',
|
519
|
+
'ASHRAE 169-2013-0B',
|
520
|
+
'ASHRAE 169-2013-1B',
|
521
|
+
'ASHRAE 169-2013-2B',
|
522
|
+
'ASHRAE 169-2013-5C'
|
523
|
+
if pct_oa < 0.1
|
524
|
+
erv_cfm = nil
|
525
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
526
|
+
erv_cfm = nil
|
527
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
528
|
+
erv_cfm = nil
|
529
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
530
|
+
erv_cfm = nil
|
531
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
532
|
+
erv_cfm = nil
|
533
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
534
|
+
erv_cfm = 26_000
|
535
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
536
|
+
erv_cfm = 12_000
|
537
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
538
|
+
erv_cfm = 5000
|
539
|
+
elsif pct_oa >= 0.8
|
540
|
+
erv_cfm = 4000
|
541
|
+
end
|
542
|
+
when 'ASHRAE 169-2006-6B',
|
543
|
+
'ASHRAE 169-2013-6B'
|
544
|
+
if pct_oa < 0.1
|
545
|
+
erv_cfm = nil
|
546
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
547
|
+
erv_cfm = 28_000
|
548
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
549
|
+
erv_cfm = 26_500
|
550
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
551
|
+
erv_cfm = 11_000
|
552
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
553
|
+
erv_cfm = 5500
|
554
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
555
|
+
erv_cfm = 4500
|
556
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
557
|
+
erv_cfm = 3500
|
558
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
559
|
+
erv_cfm = 2500
|
560
|
+
elsif pct_oa >= 0.8
|
561
|
+
erv_cfm = 1500
|
562
|
+
end
|
563
|
+
when 'ASHRAE 169-2006-0A',
|
564
|
+
'ASHRAE 169-2006-1A',
|
565
|
+
'ASHRAE 169-2006-2A',
|
566
|
+
'ASHRAE 169-2006-3A',
|
567
|
+
'ASHRAE 169-2006-4A',
|
568
|
+
'ASHRAE 169-2006-5A',
|
569
|
+
'ASHRAE 169-2006-6A',
|
570
|
+
'ASHRAE 169-2013-0A',
|
571
|
+
'ASHRAE 169-2006-1A',
|
572
|
+
'ASHRAE 169-2013-2A',
|
573
|
+
'ASHRAE 169-2013-3A',
|
574
|
+
'ASHRAE 169-2013-4A',
|
575
|
+
'ASHRAE 169-2013-5A',
|
576
|
+
'ASHRAE 169-2013-6A'
|
577
|
+
if pct_oa < 0.1
|
578
|
+
erv_cfm = nil
|
579
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
580
|
+
erv_cfm = 26_000
|
581
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
582
|
+
erv_cfm = 16_000
|
583
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
584
|
+
erv_cfm = 5500
|
585
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
586
|
+
erv_cfm = 4500
|
587
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
588
|
+
erv_cfm = 3500
|
589
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
590
|
+
erv_cfm = 2000
|
591
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
592
|
+
erv_cfm = 1000
|
593
|
+
elsif pct_oa >= 0.8
|
594
|
+
erv_cfm = 120
|
595
|
+
end
|
596
|
+
when 'ASHRAE 169-2006-7A',
|
597
|
+
'ASHRAE 169-2006-7B',
|
598
|
+
'ASHRAE 169-2006-8A',
|
599
|
+
'ASHRAE 169-2006-8B',
|
600
|
+
'ASHRAE 169-2013-7A',
|
601
|
+
'ASHRAE 169-2013-7B',
|
602
|
+
'ASHRAE 169-2013-8A',
|
603
|
+
'ASHRAE 169-2013-8B'
|
604
|
+
if pct_oa < 0.1
|
605
|
+
erv_cfm = nil
|
606
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
607
|
+
erv_cfm = 4500
|
608
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
609
|
+
erv_cfm = 4000
|
610
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
611
|
+
erv_cfm = 2500
|
612
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
613
|
+
erv_cfm = 1000
|
614
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
615
|
+
erv_cfm = 140
|
616
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
617
|
+
erv_cfm = 120
|
618
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
619
|
+
erv_cfm = 100
|
620
|
+
elsif pct_oa >= 0.8
|
621
|
+
erv_cfm = 80
|
622
|
+
end
|
623
|
+
end
|
624
|
+
else
|
625
|
+
# Table 6.5.6.1-2, above 8000 hrs
|
626
|
+
case climate_zone
|
627
|
+
when 'ASHRAE 169-2006-3C',
|
628
|
+
'ASHRAE 169-2013-3C'
|
629
|
+
erv_cfm = nil
|
630
|
+
when 'ASHRAE 169-2006-0B',
|
631
|
+
'ASHRAE 169-2006-1B',
|
632
|
+
'ASHRAE 169-2006-2B',
|
633
|
+
'ASHRAE 169-2006-3B',
|
634
|
+
'ASHRAE 169-2006-4C',
|
635
|
+
'ASHRAE 169-2006-5C',
|
636
|
+
'ASHRAE 169-2013-0B',
|
637
|
+
'ASHRAE 169-2013-1B',
|
638
|
+
'ASHRAE 169-2013-2B',
|
639
|
+
'ASHRAE 169-2013-3B',
|
640
|
+
'ASHRAE 169-2013-4C',
|
641
|
+
'ASHRAE 169-2013-5C'
|
642
|
+
if pct_oa < 0.1
|
643
|
+
erv_cfm = nil
|
644
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
645
|
+
erv_cfm = nil
|
646
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
647
|
+
erv_cfm = 19_500
|
648
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
649
|
+
erv_cfm = 9000
|
650
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
651
|
+
erv_cfm = 5000
|
652
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
653
|
+
erv_cfm = 4000
|
654
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
655
|
+
erv_cfm = 3000
|
656
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
657
|
+
erv_cfm = 1500
|
658
|
+
elsif pct_oa >= 0.8
|
659
|
+
erv_cfm = 120
|
660
|
+
end
|
661
|
+
when 'ASHRAE 169-2006-0A',
|
662
|
+
'ASHRAE 169-2006-1A',
|
663
|
+
'ASHRAE 169-2006-2A',
|
664
|
+
'ASHRAE 169-2006-3A',
|
665
|
+
'ASHRAE 169-2006-4B',
|
666
|
+
'ASHRAE 169-2006-5B',
|
667
|
+
'ASHRAE 169-2013-0A',
|
668
|
+
'ASHRAE 169-2013-1A',
|
669
|
+
'ASHRAE 169-2013-2A',
|
670
|
+
'ASHRAE 169-2013-3A',
|
671
|
+
'ASHRAE 169-2013-4B',
|
672
|
+
'ASHRAE 169-2013-5B'
|
673
|
+
if pct_oa < 0.1
|
674
|
+
erv_cfm = nil
|
675
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
676
|
+
erv_cfm = 2500
|
677
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
678
|
+
erv_cfm = 2000
|
679
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
680
|
+
erv_cfm = 1000
|
681
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
682
|
+
erv_cfm = 500
|
683
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
684
|
+
erv_cfm = 140
|
685
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
686
|
+
erv_cfm = 120
|
687
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
688
|
+
erv_cfm = 100
|
689
|
+
elsif pct_oa >= 0.8
|
690
|
+
erv_cfm = 80
|
691
|
+
end
|
692
|
+
when 'ASHRAE 169-2006-4A',
|
693
|
+
'ASHRAE 169-2006-5A',
|
694
|
+
'ASHRAE 169-2006-6A',
|
695
|
+
'ASHRAE 169-2006-6B',
|
696
|
+
'ASHRAE 169-2006-7A',
|
697
|
+
'ASHRAE 169-2006-7B',
|
698
|
+
'ASHRAE 169-2006-8A',
|
699
|
+
'ASHRAE 169-2006-8B',
|
700
|
+
'ASHRAE 169-2013-4A',
|
701
|
+
'ASHRAE 169-2013-5A',
|
702
|
+
'ASHRAE 169-2013-6A',
|
703
|
+
'ASHRAE 169-2013-6B',
|
704
|
+
'ASHRAE 169-2013-7A',
|
705
|
+
'ASHRAE 169-2013-7B',
|
706
|
+
'ASHRAE 169-2013-8A',
|
707
|
+
'ASHRAE 169-2013-8B'
|
708
|
+
if pct_oa < 0.1
|
709
|
+
erv_cfm = nil
|
710
|
+
elsif pct_oa >= 0.1 && pct_oa < 0.2
|
711
|
+
erv_cfm = 200
|
712
|
+
elsif pct_oa >= 0.2 && pct_oa < 0.3
|
713
|
+
erv_cfm = 130
|
714
|
+
elsif pct_oa >= 0.3 && pct_oa < 0.4
|
715
|
+
erv_cfm = 100
|
716
|
+
elsif pct_oa >= 0.4 && pct_oa < 0.5
|
717
|
+
erv_cfm = 80
|
718
|
+
elsif pct_oa >= 0.5 && pct_oa < 0.6
|
719
|
+
erv_cfm = 70
|
720
|
+
elsif pct_oa >= 0.6 && pct_oa < 0.7
|
721
|
+
erv_cfm = 60
|
722
|
+
elsif pct_oa >= 0.7 && pct_oa < 0.8
|
723
|
+
erv_cfm = 50
|
724
|
+
elsif pct_oa >= 0.8
|
725
|
+
erv_cfm = 40
|
726
|
+
end
|
727
|
+
end
|
728
|
+
end
|
729
|
+
|
730
|
+
return erv_cfm
|
731
|
+
end
|
732
|
+
|
733
|
+
# Determine whether to apply an Energy Recovery Ventilator 'ERV' or a Heat Recovery Ventilator 'HRV' depending on the climate zone
|
734
|
+
# Defaults to ERV.
|
735
|
+
# @return [String] the ERV type
|
736
|
+
def air_loop_hvac_energy_recovery_ventilator_type(air_loop_hvac, climate_zone)
|
737
|
+
erv_type = 'ERV'
|
738
|
+
return erv_type
|
739
|
+
end
|
740
|
+
|
741
|
+
# Determine whether to use a Plate-Frame or Rotary Wheel style ERV depending on air loop outdoor air flow rate
|
742
|
+
# Defaults to Rotary.
|
743
|
+
# @return [String] the ERV type
|
744
|
+
def air_loop_hvac_energy_recovery_ventilator_heat_exchanger_type(air_loop_hvac)
|
745
|
+
# Get the OA system
|
746
|
+
if air_loop_hvac.airLoopHVACOutdoorAirSystem.is_initialized
|
747
|
+
oa_system = air_loop_hvac.airLoopHVACOutdoorAirSystem.get
|
748
|
+
controller_oa = oa_system.getControllerOutdoorAir
|
749
|
+
else
|
750
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.nrel_zne_ready_2017.AirLoopHVAC', "For #{air_loop_hvac.name}, ERV type not applicable because it has no OA intake.")
|
751
|
+
return false
|
752
|
+
end
|
753
|
+
|
754
|
+
# Get the minimum OA flow rate
|
755
|
+
if controller_oa.maximumOutdoorAirFlowRate.is_initialized
|
756
|
+
max_oa_flow_m3_per_s = controller_oa.maximumOutdoorAirFlowRate.get
|
757
|
+
elsif controller_oa.autosizedMaximumOutdoorAirFlowRate.is_initialized
|
758
|
+
max_oa_flow_m3_per_s = controller_oa.autosizedMaximumOutdoorAirFlowRate.get
|
759
|
+
else
|
760
|
+
OpenStudio.logFree(OpenStudio::Warn, 'openstudio.nrel_zne_ready_2017.AirLoopHVAC', "For #{controller_oa.name}: maximum OA flow rate is not available, cannot determine ERV type.")
|
761
|
+
return false
|
762
|
+
end
|
763
|
+
max_oa_flow_cfm = OpenStudio.convert(max_oa_flow_m3_per_s, 'm^3/s', 'cfm').get
|
764
|
+
|
765
|
+
# Use a 500 cfm threshold
|
766
|
+
if max_oa_flow_cfm < 500.0
|
767
|
+
heat_exchanger_type = 'Plate'
|
768
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.nrel_zne_ready_2017.AirLoopHVAC', "For #{air_loop_hvac.name}, maximum outdoor air flow rate is less than 500 cfm, assuming a plate and frame heat exchanger.")
|
769
|
+
else
|
770
|
+
heat_exchanger_type = 'Rotary'
|
771
|
+
OpenStudio.logFree(OpenStudio::Info, 'openstudio.nrel_zne_ready_2017.AirLoopHVAC', "For #{air_loop_hvac.name}, maximum outdoor air flow rate is greater than 500 cfm, assuming a rotary wheel heat exchanger.")
|
772
|
+
end
|
773
|
+
|
774
|
+
return heat_exchanger_type
|
775
|
+
end
|
776
|
+
|
777
|
+
# Apply efficiency values to the erv
|
778
|
+
#
|
779
|
+
# @param erv [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] erv to apply efficiency values
|
780
|
+
# @param erv_type [String] erv type ERV or HRV
|
781
|
+
# @param heat_exchanger_type [String] heat exchanger type Rotary or Plate
|
782
|
+
# @return erv [OpenStudio::Model::HeatExchangerAirToAirSensibleAndLatent] erv to apply efficiency values
|
783
|
+
def air_loop_hvac_apply_energy_recovery_ventilator_efficiency(erv, erv_type: 'ERV', heat_exchanger_type: 'Rotary')
|
784
|
+
if heat_exchanger_type == 'Plate'
|
785
|
+
# based on Zehnder ComfoAir
|
786
|
+
if erv_type == 'HRV'
|
787
|
+
erv.setSensibleEffectivenessat100HeatingAirFlow(0.865)
|
788
|
+
erv.setLatentEffectivenessat100HeatingAirFlow(0.0)
|
789
|
+
erv.setSensibleEffectivenessat75HeatingAirFlow(0.887)
|
790
|
+
erv.setLatentEffectivenessat75HeatingAirFlow(0.0)
|
791
|
+
erv.setSensibleEffectivenessat100CoolingAirFlow(0.865)
|
792
|
+
erv.setLatentEffectivenessat100CoolingAirFlow(0.0)
|
793
|
+
erv.setSensibleEffectivenessat75CoolingAirFlow(0.887)
|
794
|
+
erv.setLatentEffectivenessat75CoolingAirFlow(0.0)
|
795
|
+
else
|
796
|
+
erv.setSensibleEffectivenessat100HeatingAirFlow(0.755)
|
797
|
+
erv.setLatentEffectivenessat100HeatingAirFlow(0.564)
|
798
|
+
erv.setSensibleEffectivenessat75HeatingAirFlow(0.791)
|
799
|
+
erv.setLatentEffectivenessat75HeatingAirFlow(0.625)
|
800
|
+
erv.setSensibleEffectivenessat100CoolingAirFlow(0.755)
|
801
|
+
erv.setLatentEffectivenessat100CoolingAirFlow(0.564)
|
802
|
+
erv.setSensibleEffectivenessat75CoolingAirFlow(0.791)
|
803
|
+
erv.setLatentEffectivenessat75CoolingAirFlow(0.625)
|
804
|
+
end
|
805
|
+
else
|
806
|
+
if erv_type == 'HRV'
|
807
|
+
erv.setSensibleEffectivenessat100HeatingAirFlow(0.75)
|
808
|
+
erv.setLatentEffectivenessat100HeatingAirFlow(0.0)
|
809
|
+
erv.setSensibleEffectivenessat75HeatingAirFlow(0.79)
|
810
|
+
erv.setLatentEffectivenessat75HeatingAirFlow(0.0)
|
811
|
+
erv.setSensibleEffectivenessat100CoolingAirFlow(0.75)
|
812
|
+
erv.setLatentEffectivenessat100CoolingAirFlow(0.0)
|
813
|
+
erv.setSensibleEffectivenessat75CoolingAirFlow(0.78)
|
814
|
+
erv.setLatentEffectivenessat75CoolingAirFlow(0.0)
|
815
|
+
else
|
816
|
+
erv.setSensibleEffectivenessat100HeatingAirFlow(0.75)
|
817
|
+
erv.setLatentEffectivenessat100HeatingAirFlow(0.74)
|
818
|
+
erv.setSensibleEffectivenessat75HeatingAirFlow(0.79)
|
819
|
+
erv.setLatentEffectivenessat75HeatingAirFlow(0.79)
|
820
|
+
erv.setSensibleEffectivenessat100CoolingAirFlow(0.75)
|
821
|
+
erv.setLatentEffectivenessat100CoolingAirFlow(0.74)
|
822
|
+
erv.setSensibleEffectivenessat75CoolingAirFlow(0.78)
|
823
|
+
erv.setLatentEffectivenessat75CoolingAirFlow(0.78)
|
824
|
+
end
|
825
|
+
end
|
826
|
+
|
827
|
+
return erv
|
828
|
+
end
|
829
|
+
end
|