openstudio-geb 0.0.1 → 0.0.2
Sign up to get free protection for your applications and to get access to all the features.
- checksums.yaml +4 -4
- data/.gitignore +3 -0
- data/lib/measures/{add_rooftop_pv → add_rooftop_pv_simple}/LICENSE.md +0 -0
- data/lib/measures/{add_rooftop_pv → add_rooftop_pv_simple}/README.md +0 -0
- data/lib/measures/{Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Enable Demand Controlled Ventilation → add_rooftop_pv_simple}/README.md.erb +0 -0
- data/lib/measures/{add_rooftop_pv → add_rooftop_pv_simple}/measure.rb +0 -0
- data/lib/measures/{add_rooftop_pv → add_rooftop_pv_simple}/measure.xml +0 -0
- data/lib/measures/{add_rooftop_pv → add_rooftop_pv_simple}/tests/CZ06RV2.epw +0 -0
- data/lib/measures/{add_rooftop_pv → add_rooftop_pv_simple}/tests/add_rooftop_pv_test.rb +0 -0
- data/lib/measures/{add_rooftop_pv → add_rooftop_pv_simple}/tests/pv_test_input.osm +0 -0
- data/lib/openstudio/geb/utilities.rb +34 -6
- data/lib/openstudio/geb/version.rb +1 -1
- data/openstudio-geb.gemspec +1 -1
- metadata +10 -126
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/files/USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.epw +0 -8768
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/files/USA_NY_Buffalo.Niagara.Intl.AP.725280_TMY3.epw +0 -8768
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Enable Demand Controlled Ventilation/LICENSE.md +0 -27
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Enable Demand Controlled Ventilation/README.md +0 -32
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Enable Demand Controlled Ventilation/measure.rb +0 -156
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Enable Demand Controlled Ventilation/measure.xml +0 -117
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Enable Demand Controlled Ventilation/tests/0320_ModelWithHVAC_01.osm +0 -22223
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Enable Demand Controlled Ventilation/tests/EnableDemandControlledVentilation_Test.rb +0 -123
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/LICENSE.md +0 -27
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/README.md +0 -136
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/README.md.erb +0 -47
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/measure.rb +0 -586
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/measure.xml +0 -200
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/tests/EnvelopeAndLoadTestModel_01.osm +0 -14352
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/tests/EnvelopeAndLoadTestModel_01_Costed.osm +0 -14438
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/tests/HasSpaceWithNoLightsOrElec.osm +0 -16531
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/measures/Set Electric Equipment loads by EPD/tests/ReplaceElectricEquipmentWithEPD_Test.rb +0 -592
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/out.osw +0 -68
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/reports/eplustbl.html +0 -27183
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/data_point.zip +0 -0
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/data_point_out.json +0 -6
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.audit +0 -49
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.bnd +0 -1103
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.eio +0 -630
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.end +0 -1
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.err +0 -331
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.eso +0 -158559
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.mdd +0 -336
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.mtd +0 -2519
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.rdd +0 -638
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.shd +0 -902
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusout.sql +0 -0
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplusssz.csv +0 -147
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/eplustbl.htm +0 -27183
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/epluszsz.csv +0 -148
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/finished.job +0 -1
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/in.idf +0 -10384
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/in.osm +0 -13809
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/measure_attributes.json +0 -6
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/objectives.json +0 -2
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/pre-preprocess.idf +0 -10134
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/results.json +0 -6
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/run.log +0 -0
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/sqlite.err +0 -1
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/started.job +0 -1
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/stdout-energyplus +0 -271
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/run/stdout-expandobject +0 -3
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/stderr +0 -0
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/stdout +0 -0
- data/lib/measures/Enable Demand Controlled Ventilation/tests/MediumOffice-90.1-2010-ASHRAE 169-2013-5A_dcv/workflow.osw +0 -19
- data/lib/measures/add_rooftop_pv/README.md.erb +0 -42
@@ -1,630 +0,0 @@
|
|
1
|
-
Program Version,EnergyPlus, Version 9.4.0-998c4b761e, YMD=2021.07.19 13:49
|
2
|
-
! <Version>, Version ID
|
3
|
-
Version, 9.4
|
4
|
-
! <Timesteps per Hour>, #TimeSteps, Minutes per TimeStep {minutes}
|
5
|
-
Timesteps per Hour, 6, 10
|
6
|
-
! <System Convergence Limits>, Minimum System TimeStep {minutes}, Max HVAC Iterations, Minimum Plant Iterations, Maximum Plant Iterations
|
7
|
-
System Convergence Limits, 1, 20, 2, 8
|
8
|
-
! <Simulation Control>, Do Zone Sizing, Do System Sizing, Do Plant Sizing, Do Design Days, Do Weather Simulation, Do HVAC Sizing Simulation
|
9
|
-
Simulation Control, Yes, Yes, Yes, No, Yes, Yes
|
10
|
-
! <Performance Precision Tradeoffs>, Use Coil Direct Simulation, Zone Radiant Exchange Algorithm, Override Mode, Number of Timestep In Hour, Force Euler Method, Minimum Number of Warmup Days, Force Suppress All Begin Environment Resets, Minimum System Timestep, MaxZoneTempDiff, MaxAllowedDelTemp
|
11
|
-
Performance Precision Tradeoffs, No, ScriptF, Normal, 6, No, 1, No, 1.0, 0.300, 2.0000E-003
|
12
|
-
! <Output Reporting Tolerances>, Tolerance for Time Heating Setpoint Not Met, Tolerance for Zone Cooling Setpoint Not Met Time
|
13
|
-
Output Reporting Tolerances, 0.200, 0.200,
|
14
|
-
! <Site:GroundTemperature:BuildingSurface>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
|
15
|
-
Site:GroundTemperature:BuildingSurface, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00, 18.00
|
16
|
-
! <Site:GroundTemperature:FCfactorMethod>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
|
17
|
-
Site:GroundTemperature:FCfactorMethod, 9.70, 6.00, -2.20, -3.40, -4.20, 2.70, 7.50, 13.70, 18.60, 22.00, 20.70, 16.50
|
18
|
-
! <Site:GroundTemperature:Shallow>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
|
19
|
-
Site:GroundTemperature:Shallow, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00, 13.00
|
20
|
-
! <Site:GroundTemperature:Deep>,Jan{C},Feb{C},Mar{C},Apr{C},May{C},Jun{C},Jul{C},Aug{C},Sep{C},Oct{C},Nov{C},Dec{C}
|
21
|
-
Site:GroundTemperature:Deep, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00, 16.00
|
22
|
-
! <Site:GroundReflectance>,Jan{dimensionless},Feb{dimensionless},Mar{dimensionless},Apr{dimensionless},May{dimensionless},Jun{dimensionless},Jul{dimensionless},Aug{dimensionless},Sep{dimensionless},Oct{dimensionless},Nov{dimensionless},Dec{dimensionless}
|
23
|
-
Site:GroundReflectance, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20
|
24
|
-
! <Site:GroundReflectance:SnowModifier>, Normal, Daylighting {dimensionless}
|
25
|
-
Site:GroundReflectance:SnowModifier, 1.000, 1.000
|
26
|
-
! <Site:GroundReflectance:Snow>,Jan{dimensionless},Feb{dimensionless},Mar{dimensionless},Apr{dimensionless},May{dimensionless},Jun{dimensionless},Jul{dimensionless},Aug{dimensionless},Sep{dimensionless},Oct{dimensionless},Nov{dimensionless},Dec{dimensionless}
|
27
|
-
Site:GroundReflectance:Snow, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20
|
28
|
-
! <Site:GroundReflectance:Snow:Daylighting>,Jan{dimensionless},Feb{dimensionless},Mar{dimensionless},Apr{dimensionless},May{dimensionless},Jun{dimensionless},Jul{dimensionless},Aug{dimensionless},Sep{dimensionless},Oct{dimensionless},Nov{dimensionless},Dec{dimensionless}
|
29
|
-
Site:GroundReflectance:Snow:Daylighting, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20, 0.20
|
30
|
-
! <Environment:Weather Station>,Wind Sensor Height Above Ground {m},Wind Speed Profile Exponent {},Wind Speed Profile Boundary Layer Thickness {m},Air Temperature Sensor Height Above Ground {m},Wind Speed Modifier Coefficient-Internal,Temperature Modifier Coefficient-Internal
|
31
|
-
Environment:Weather Station,10.000,0.140,270.000,1.500,1.586,9.750E-003
|
32
|
-
! <Site:Location>, Location Name, Latitude {N+/S- Deg}, Longitude {E+/W- Deg}, Time Zone Number {GMT+/-}, Elevation {m}, Standard Pressure at Elevation {Pa}, Standard RhoAir at Elevation
|
33
|
-
Site:Location,Chicago Ohare Intl Ap IL USA TMY3 WMO#=725300,41.98,-87.92,-6.00,201.00,98934,1.1759
|
34
|
-
! <Site Water Mains Temperature Information>,Calculation Method{},Water Mains Temperature Schedule Name{},Annual Average Outdoor Air Temperature{C},Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC},Fixed Default Water Mains Temperature{C}
|
35
|
-
Site Water Mains Temperature Information,Correlation,NA,8.97,26.20,NA
|
36
|
-
! <Building Information>, Building Name,North Axis {deg},Terrain, Loads Convergence Tolerance Value,Temperature Convergence Tolerance Value, Solar Distribution,Maximum Number of Warmup Days,Minimum Number of Warmup Days
|
37
|
-
Building Information,-MediumOffice-ASHRAE 169-2013-5A created: 2021-03-07 23:30:32 -0800,0.000,City,4.00000E-002,0.20000,FullInteriorAndExterior,25,6
|
38
|
-
! <Inside Convection Algorithm>, Algorithm {Simple | TARP | CeilingDiffuser | AdaptiveConvectionAlgorithm}
|
39
|
-
Inside Convection Algorithm,TARP
|
40
|
-
! <Outside Convection Algorithm>, Algorithm {SimpleCombined | TARP | MoWitt | DOE-2 | AdaptiveConvectionAlgorithm}
|
41
|
-
Outside Convection Algorithm,TARP
|
42
|
-
! <Sky Radiance Distribution>, Value {Anisotropic}
|
43
|
-
Sky Radiance Distribution,Anisotropic
|
44
|
-
! <Zone Air Solution Algorithm>, Value {ThirdOrderBackwardDifference | AnalyticalSolution | EulerMethod}
|
45
|
-
Zone Air Solution Algorithm, ThirdOrderBackwardDifference
|
46
|
-
! <Zone Air Carbon Dioxide Balance Simulation>, Simulation {Yes/No}, Carbon Dioxide Concentration
|
47
|
-
Zone Air Carbon Dioxide Balance Simulation, No,N/A
|
48
|
-
! <Zone Air Generic Contaminant Balance Simulation>, Simulation {Yes/No}, Generic Contaminant Concentration
|
49
|
-
Zone Air Generic Contaminant Balance Simulation, No,N/A
|
50
|
-
! <Zone Air Mass Flow Balance Simulation>, Enforce Mass Balance, Adjust Zone Mixing, Adjust Zone Infiltration {AddInfiltration | AdjustInfiltration | None}, Infiltration Zones {MixingSourceZonesOnly | AllZones}
|
51
|
-
Zone Air Mass Flow Balance Simulation, No,N/A,N/A,N/A
|
52
|
-
! <HVACSystemRootFindingAlgorithm>, Value {RegulaFalsi | Bisection | BisectionThenRegulaFalsi | RegulaFalsiThenBisection}
|
53
|
-
HVACSystemRootFindingAlgorithm, RegulaFalsi
|
54
|
-
! <Environment:Site Atmospheric Variation>,Wind Speed Profile Exponent {},Wind Speed Profile Boundary Layer Thickness {m},Air Temperature Gradient Coefficient {K/m}
|
55
|
-
Environment:Site Atmospheric Variation,0.330,460.000,6.500000E-003
|
56
|
-
! <Surface Geometry>,Starting Corner,Vertex Input Direction,Coordinate System,Daylight Reference Point Coordinate System,Rectangular (Simple) Surface Coordinate System
|
57
|
-
Surface Geometry,UpperLeftCorner,Counterclockwise,RelativeCoordinateSystem,RelativeCoordinateSystem,RelativeToZoneOrigin
|
58
|
-
! <Surface Heat Transfer Algorithm>, Value {CTF - ConductionTransferFunction | EMPD - MoisturePenetrationDepthConductionTransferFunction | CondFD - ConductionFiniteDifference | HAMT - CombinedHeatAndMoistureFiniteElement} - Description,Inside Surface Max Temperature Limit{C}, Surface Convection Coefficient Lower Limit {W/m2-K}, Surface Convection Coefficient Upper Limit {W/m2-K}
|
59
|
-
Surface Heat Transfer Algorithm, CTF - ConductionTransferFunction,200,0.10,1000.0
|
60
|
-
! <Shading Summary>, Number of Fixed Detached Shades, Number of Building Detached Shades, Number of Attached Shades
|
61
|
-
Shading Summary,0,0,0
|
62
|
-
! <Zone Summary>, Number of Zones, Number of Zone Surfaces, Number of SubSurfaces
|
63
|
-
Zone Summary,18,164,18
|
64
|
-
! <Zone Information>,Zone Name,North Axis {deg},Origin X-Coordinate {m},Origin Y-Coordinate {m},Origin Z-Coordinate {m},Centroid X-Coordinate {m},Centroid Y-Coordinate {m},Centroid Z-Coordinate {m},Type,Zone Multiplier,Zone List Multiplier,Minimum X {m},Maximum X {m},Minimum Y {m},Maximum Y {m},Minimum Z {m},Maximum Z {m},Ceiling Height {m},Volume {m3},Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall},Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST}, Floor Area {m2},Exterior Gross Wall Area {m2},Exterior Net Wall Area {m2},Exterior Window Area {m2}, Number of Surfaces, Number of SubSurfaces, Number of Shading SubSurfaces, Part of Total Building Area
|
65
|
-
Zone Information, CORE_BOTTOM ZN,0.0,0.00,0.00,0.00,24.96,16.64,1.37,1,1,1,4.57,45.34,4.57,28.70,0.00,2.74,2.74,2698.04,TARP,TARP,983.54,0.00,0.00,0.00,6,0,0,Yes
|
66
|
-
Zone Information, CORE_MID ZN,0.0,0.00,0.00,0.00,24.96,16.64,5.33,1,1,1,4.57,45.34,4.57,28.70,3.96,6.71,2.74,2698.04,TARP,TARP,983.54,0.00,0.00,0.00,6,0,0,Yes
|
67
|
-
Zone Information, CORE_TOP ZN,0.0,0.00,0.00,0.00,24.96,16.64,9.30,1,1,1,4.57,45.34,4.57,28.70,7.92,10.67,2.74,2698.04,TARP,TARP,983.54,0.00,0.00,0.00,6,0,0,Yes
|
68
|
-
Zone Information, FIRSTFLOOR_PLENUM ZN,0.0,0.00,0.00,0.00,24.96,16.64,3.35,1,1,1,0.00,49.91,0.00,33.27,2.74,3.96,1.22,2024.76,TARP,TARP,1660.73,202.84,202.84,0.00,14,0,0,No
|
69
|
-
Zone Information, MIDFLOOR_PLENUM ZN,0.0,0.00,0.00,0.00,24.96,16.64,7.32,1,1,1,0.00,49.91,0.00,33.27,6.71,7.92,1.22,2024.76,TARP,TARP,1660.73,202.84,202.84,0.00,14,0,0,No
|
70
|
-
Zone Information, PERIMETER_BOT_ZN_1 ZN,0.0,0.00,0.00,0.00,24.96,2.16,1.37,1,1,1,0.00,49.91,0.00,4.57,0.00,2.74,2.74,568.77,TARP,TARP,207.34,136.92,67.73,65.28,6,3,0,Yes
|
71
|
-
Zone Information, PERIMETER_BOT_ZN_2 ZN,0.0,0.00,0.00,0.00,47.82,16.64,1.37,1,1,1,45.34,49.91,0.00,33.27,0.00,2.74,2.74,360.08,TARP,TARP,131.26,91.28,45.80,43.52,6,2,0,Yes
|
72
|
-
Zone Information, PERIMETER_BOT_ZN_3 ZN,0.0,0.00,0.00,0.00,24.96,31.11,1.37,1,1,1,0.00,49.91,28.70,33.27,0.00,2.74,2.74,568.77,TARP,TARP,207.34,136.92,67.73,65.28,6,3,0,Yes
|
73
|
-
Zone Information, PERIMETER_BOT_ZN_4 ZN,0.0,0.00,0.00,0.00,2.09,16.64,1.37,1,1,1,0.00,4.57,0.00,33.27,0.00,2.74,2.74,360.05,TARP,TARP,131.25,91.28,45.80,43.52,6,2,0,Yes
|
74
|
-
Zone Information, PERIMETER_MID_ZN_1 ZN,0.0,0.00,0.00,0.00,24.96,2.16,5.33,1,1,1,0.00,49.91,0.00,4.57,3.96,6.71,2.74,568.77,TARP,TARP,207.34,136.92,71.63,65.28,6,1,0,Yes
|
75
|
-
Zone Information, PERIMETER_MID_ZN_2 ZN,0.0,0.00,0.00,0.00,47.82,16.64,5.33,1,1,1,45.34,49.91,0.00,33.27,3.96,6.71,2.74,360.08,TARP,TARP,131.26,91.28,47.75,43.52,6,1,0,Yes
|
76
|
-
Zone Information, PERIMETER_MID_ZN_3 ZN,0.0,0.00,0.00,0.00,24.96,31.11,5.33,1,1,1,0.00,49.91,28.70,33.27,3.96,6.71,2.74,568.77,TARP,TARP,207.34,136.92,71.63,65.28,6,1,0,Yes
|
77
|
-
Zone Information, PERIMETER_MID_ZN_4 ZN,0.0,0.00,0.00,0.00,2.09,16.64,5.33,1,1,1,0.00,4.57,0.00,33.27,3.96,6.71,2.74,360.05,TARP,TARP,131.25,91.28,47.75,43.52,6,1,0,Yes
|
78
|
-
Zone Information, PERIMETER_TOP_ZN_1 ZN,0.0,0.00,0.00,0.00,24.96,2.16,9.30,1,1,1,0.00,49.91,0.00,4.57,7.92,10.67,2.74,568.77,TARP,TARP,207.34,136.92,71.63,65.28,6,1,0,Yes
|
79
|
-
Zone Information, PERIMETER_TOP_ZN_2 ZN,0.0,0.00,0.00,0.00,47.82,16.64,9.30,1,1,1,45.34,49.91,0.00,33.27,7.92,10.67,2.74,360.08,TARP,TARP,131.26,91.28,47.75,43.52,6,1,0,Yes
|
80
|
-
Zone Information, PERIMETER_TOP_ZN_3 ZN,0.0,0.00,0.00,0.00,24.96,31.11,9.30,1,1,1,0.00,49.91,28.70,33.27,7.92,10.67,2.74,568.77,TARP,TARP,207.34,136.92,71.63,65.28,6,1,0,Yes
|
81
|
-
Zone Information, PERIMETER_TOP_ZN_4 ZN,0.0,0.00,0.00,0.00,2.09,16.64,9.30,1,1,1,0.00,4.57,0.00,33.27,7.92,10.67,2.74,360.05,TARP,TARP,131.25,91.28,47.75,43.52,6,1,0,Yes
|
82
|
-
Zone Information, TOPFLOOR_PLENUM ZN,0.0,0.00,0.00,0.00,24.96,16.64,11.28,1,1,1,0.00,49.91,0.00,33.27,10.67,11.89,1.22,2024.76,TARP,TARP,1660.73,202.84,202.84,0.00,10,0,0,No
|
83
|
-
! <Zone Internal Gains Nominal>,Zone Name, Floor Area {m2},# Occupants,Area per Occupant {m2/person},Occupant per Area {person/m2},Interior Lighting {W/m2},Electric Load {W/m2},Gas Load {W/m2},Other Load {W/m2},Hot Water Eq {W/m2},Steam Equipment {W/m2},Sum Loads per Area {W/m2},Outdoor Controlled Baseboard Heat
|
84
|
-
Zone Internal Gains Nominal, CORE_BOTTOM ZN,983.54,52.9,18.581,5.382E-002,9.688,40.938,0.000,0.000,0.000,0.000,50.626,No
|
85
|
-
Zone Internal Gains Nominal, CORE_MID ZN,983.54,52.9,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
86
|
-
Zone Internal Gains Nominal, CORE_TOP ZN,983.54,52.9,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
87
|
-
Zone Internal Gains Nominal, FIRSTFLOOR_PLENUM ZN,1660.73,0.0,N/A,0.000,0.000,0.000,0.000,0.000,0.000,0.000,0.000,No
|
88
|
-
Zone Internal Gains Nominal, MIDFLOOR_PLENUM ZN,1660.73,0.0,N/A,0.000,0.000,0.000,0.000,0.000,0.000,0.000,0.000,No
|
89
|
-
Zone Internal Gains Nominal, PERIMETER_BOT_ZN_1 ZN,207.34,11.2,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
90
|
-
Zone Internal Gains Nominal, PERIMETER_BOT_ZN_2 ZN,131.26,7.1,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
91
|
-
Zone Internal Gains Nominal, PERIMETER_BOT_ZN_3 ZN,207.34,11.2,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
92
|
-
Zone Internal Gains Nominal, PERIMETER_BOT_ZN_4 ZN,131.25,7.1,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
93
|
-
Zone Internal Gains Nominal, PERIMETER_MID_ZN_1 ZN,207.34,11.2,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
94
|
-
Zone Internal Gains Nominal, PERIMETER_MID_ZN_2 ZN,131.26,7.1,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
95
|
-
Zone Internal Gains Nominal, PERIMETER_MID_ZN_3 ZN,207.34,11.2,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
96
|
-
Zone Internal Gains Nominal, PERIMETER_MID_ZN_4 ZN,131.25,7.1,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
97
|
-
Zone Internal Gains Nominal, PERIMETER_TOP_ZN_1 ZN,207.34,11.2,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
98
|
-
Zone Internal Gains Nominal, PERIMETER_TOP_ZN_2 ZN,131.26,7.1,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
99
|
-
Zone Internal Gains Nominal, PERIMETER_TOP_ZN_3 ZN,207.34,11.2,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
100
|
-
Zone Internal Gains Nominal, PERIMETER_TOP_ZN_4 ZN,131.25,7.1,18.581,5.382E-002,9.688,8.073,0.000,0.000,0.000,0.000,17.760,No
|
101
|
-
Zone Internal Gains Nominal, TOPFLOOR_PLENUM ZN,1660.73,0.0,N/A,0.000,0.000,0.000,0.000,0.000,0.000,0.000,0.000,No
|
102
|
-
! <People Internal Gains Nominal>,Name,Schedule Name,Zone Name,Zone Floor Area {m2},# Zone Occupants,Number of People {},People/Floor Area {person/m2},Floor Area per person {m2/person},Fraction Radiant,Fraction Convected,Sensible Fraction Calculation,Activity level,ASHRAE 55 Warnings,Carbon Dioxide Generation Rate,Nominal Minimum Number of People,Nominal Maximum Number of People
|
103
|
-
People Internal Gains Nominal, CORE_BOTTOM ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,CORE_BOTTOM ZN,983.54,52.9,52.9,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,53
|
104
|
-
People Internal Gains Nominal, CORE_MID ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,CORE_MID ZN,983.54,52.9,52.9,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,53
|
105
|
-
People Internal Gains Nominal, CORE_TOP ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,CORE_TOP ZN,983.54,52.9,52.9,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,53
|
106
|
-
People Internal Gains Nominal, PERIMETER_BOT_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_BOT_ZN_1 ZN,207.34,11.2,11.2,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,11
|
107
|
-
People Internal Gains Nominal, PERIMETER_BOT_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_BOT_ZN_2 ZN,131.26,7.1,7.1,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,7
|
108
|
-
People Internal Gains Nominal, PERIMETER_BOT_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_BOT_ZN_3 ZN,207.34,11.2,11.2,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,11
|
109
|
-
People Internal Gains Nominal, PERIMETER_BOT_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_BOT_ZN_4 ZN,131.25,7.1,7.1,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,7
|
110
|
-
People Internal Gains Nominal, PERIMETER_MID_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_MID_ZN_1 ZN,207.34,11.2,11.2,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,11
|
111
|
-
People Internal Gains Nominal, PERIMETER_MID_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_MID_ZN_2 ZN,131.26,7.1,7.1,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,7
|
112
|
-
People Internal Gains Nominal, PERIMETER_MID_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_MID_ZN_3 ZN,207.34,11.2,11.2,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,11
|
113
|
-
People Internal Gains Nominal, PERIMETER_MID_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_MID_ZN_4 ZN,131.25,7.1,7.1,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,7
|
114
|
-
People Internal Gains Nominal, PERIMETER_TOP_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_TOP_ZN_1 ZN,207.34,11.2,11.2,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,11
|
115
|
-
People Internal Gains Nominal, PERIMETER_TOP_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_TOP_ZN_2 ZN,131.26,7.1,7.1,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,7
|
116
|
-
People Internal Gains Nominal, PERIMETER_TOP_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_TOP_ZN_3 ZN,207.34,11.2,11.2,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,11
|
117
|
-
People Internal Gains Nominal, PERIMETER_TOP_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE PEOPLE,OFFICEMEDIUM BLDG_OCC_SCH,PERIMETER_TOP_ZN_4 ZN,131.25,7.1,7.1,5.382E-002,18.581,0.300,0.700,AutoCalculate,OFFICEMEDIUM ACTIVITY_SCH,No,3.8200E-008,0,7
|
118
|
-
! <Lights Internal Gains Nominal>,Name,Schedule Name,Zone Name,Zone Floor Area {m2},# Zone Occupants,Lighting Level {W},Lights/Floor Area {W/m2},Lights per person {W/person},Fraction Return Air,Fraction Radiant,Fraction Short Wave,Fraction Convected,Fraction Replaceable,End-Use Category,Nominal Minimum Lighting Level {W},Nominal Maximum Lighting Level {W}
|
119
|
-
Lights Internal Gains Nominal, CORE_BOTTOM ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,CORE_BOTTOM ZN,983.54,52.9,9528.030,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,9528.030
|
120
|
-
Lights Internal Gains Nominal, CORE_MID ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,CORE_MID ZN,983.54,52.9,9528.030,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,9528.030
|
121
|
-
Lights Internal Gains Nominal, CORE_TOP ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,CORE_TOP ZN,983.54,52.9,9528.030,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,9528.030
|
122
|
-
Lights Internal Gains Nominal, PERIMETER_BOT_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_BOT_ZN_1 ZN,207.34,11.2,2008.592,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,2008.592
|
123
|
-
Lights Internal Gains Nominal, PERIMETER_BOT_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_BOT_ZN_2 ZN,131.26,7.1,1271.605,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,1271.605
|
124
|
-
Lights Internal Gains Nominal, PERIMETER_BOT_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_BOT_ZN_3 ZN,207.34,11.2,2008.592,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,2008.592
|
125
|
-
Lights Internal Gains Nominal, PERIMETER_BOT_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_BOT_ZN_4 ZN,131.25,7.1,1271.522,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,1271.522
|
126
|
-
Lights Internal Gains Nominal, PERIMETER_MID_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_MID_ZN_1 ZN,207.34,11.2,2008.592,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,2008.592
|
127
|
-
Lights Internal Gains Nominal, PERIMETER_MID_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_MID_ZN_2 ZN,131.26,7.1,1271.605,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,1271.605
|
128
|
-
Lights Internal Gains Nominal, PERIMETER_MID_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_MID_ZN_3 ZN,207.34,11.2,2008.592,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,2008.592
|
129
|
-
Lights Internal Gains Nominal, PERIMETER_MID_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_MID_ZN_4 ZN,131.25,7.1,1271.522,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,1271.522
|
130
|
-
Lights Internal Gains Nominal, PERIMETER_TOP_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_TOP_ZN_1 ZN,207.34,11.2,2008.592,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,2008.592
|
131
|
-
Lights Internal Gains Nominal, PERIMETER_TOP_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_TOP_ZN_2 ZN,131.26,7.1,1271.605,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,1271.605
|
132
|
-
Lights Internal Gains Nominal, PERIMETER_TOP_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_TOP_ZN_3 ZN,207.34,11.2,2008.592,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,2008.592
|
133
|
-
Lights Internal Gains Nominal, PERIMETER_TOP_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE LIGHTS,OFFICEMEDIUM BLDG_LIGHT_SCH_2010,PERIMETER_TOP_ZN_4 ZN,131.25,7.1,1271.522,9.688,180.000,0.000,0.700,0.200,0.100,1.000,General,0.000,1271.522
|
134
|
-
! <ElectricEquipment Internal Gains Nominal>,Name,Schedule Name,Zone Name,Zone Floor Area {m2},# Zone Occupants,Equipment Level {W},Equipment/Floor Area {W/m2},Equipment per person {W/person},Fraction Latent,Fraction Radiant,Fraction Lost,Fraction Convected,End-Use SubCategory,Nominal Minimum Equipment Level {W},Nominal Maximum Equipment Level {W}
|
135
|
-
ElectricEquipment Internal Gains Nominal, 2 ELEVATOR FANS,OFFICEMEDIUM ELEV_LIGHT_FAN_SCH_ADD_DF,CORE_BOTTOM ZN,983.54,52.9,149.450,0.152,2.823,0.000,0.500,0.000,0.500,Elevators,0.000,103.121
|
136
|
-
ElectricEquipment Internal Gains Nominal, 2 ELEVATOR LIFT MOTORS,OFFICEMEDIUM BLDG_ELEVATORS,CORE_BOTTOM ZN,983.54,52.9,32110.000,32.647,606.610,0.000,0.500,0.000,0.500,Elevators,0.000,22155.900
|
137
|
-
ElectricEquipment Internal Gains Nominal, 2 ELEVATOR LIGHTS,OFFICEMEDIUM ELEV_LIGHT_FAN_SCH_ADD_DF,CORE_BOTTOM ZN,983.54,52.9,64.697,6.578E-002,1.222,0.000,0.500,0.000,0.500,Elevators,0.000,44.641
|
138
|
-
ElectricEquipment Internal Gains Nominal, CORE_BOTTOM ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,CORE_BOTTOM ZN,983.54,52.9,7940.025,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,7940.025
|
139
|
-
ElectricEquipment Internal Gains Nominal, CORE_MID ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,CORE_MID ZN,983.54,52.9,7940.025,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,7940.025
|
140
|
-
ElectricEquipment Internal Gains Nominal, CORE_TOP ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,CORE_TOP ZN,983.54,52.9,7940.025,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,7940.025
|
141
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_BOT_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_BOT_ZN_1 ZN,207.34,11.2,1673.827,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1673.827
|
142
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_BOT_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_BOT_ZN_2 ZN,131.26,7.1,1059.671,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1059.671
|
143
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_BOT_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_BOT_ZN_3 ZN,207.34,11.2,1673.827,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1673.827
|
144
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_BOT_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_BOT_ZN_4 ZN,131.25,7.1,1059.601,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1059.601
|
145
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_MID_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_MID_ZN_1 ZN,207.34,11.2,1673.827,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1673.827
|
146
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_MID_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_MID_ZN_2 ZN,131.26,7.1,1059.671,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1059.671
|
147
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_MID_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_MID_ZN_3 ZN,207.34,11.2,1673.827,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1673.827
|
148
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_MID_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_MID_ZN_4 ZN,131.25,7.1,1059.601,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1059.601
|
149
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_TOP_ZN_1 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_TOP_ZN_1 ZN,207.34,11.2,1673.827,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1673.827
|
150
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_TOP_ZN_2 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_TOP_ZN_2 ZN,131.26,7.1,1059.671,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1059.671
|
151
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_TOP_ZN_3 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_TOP_ZN_3 ZN,207.34,11.2,1673.827,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1673.827
|
152
|
-
ElectricEquipment Internal Gains Nominal, PERIMETER_TOP_ZN_4 ZN OFFICE WHOLEBUILDING - MD OFFICE ELEC EQUIP,OFFICEMEDIUM BLDG_EQUIP_SCH_2010,PERIMETER_TOP_ZN_4 ZN,131.25,7.1,1059.601,8.073,150.000,0.000,0.500,0.000,0.500,General,0.000,1059.601
|
153
|
-
! <Shadowing/Sun Position Calculations Annual Simulations>, Shading Calculation Method, Shading Calculation Update Frequency Method, Shading Calculation Update Frequency {days}, Maximum Figures in Shadow Overlap Calculations {}, Polygon Clipping Algorithm, Pixel Counting Resolution, Sky Diffuse Modeling Algorithm, Output External Shading Calculation Results, Disable Self-Shading Within Shading Zone Groups, Disable Self-Shading From Shading Zone Groups to Other Zones
|
154
|
-
Shadowing/Sun Position Calculations Annual Simulations,PolygonClipping,Periodic,7,15000,SutherlandHodgman,512,SimpleSkyDiffuseModeling,No,No,No
|
155
|
-
! <Zone/Window Adjacency Daylighting Counts>, Zone Name, Number of Exterior Windows, Number of Exterior Windows in Adjacent Zones
|
156
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_BOT_ZN_1 ZN,1,0
|
157
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_BOT_ZN_2 ZN,1,0
|
158
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_BOT_ZN_3 ZN,1,0
|
159
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_BOT_ZN_4 ZN,1,0
|
160
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_MID_ZN_1 ZN,1,0
|
161
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_MID_ZN_2 ZN,1,0
|
162
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_MID_ZN_3 ZN,1,0
|
163
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_MID_ZN_4 ZN,1,0
|
164
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_TOP_ZN_1 ZN,1,0
|
165
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_TOP_ZN_2 ZN,1,0
|
166
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_TOP_ZN_3 ZN,1,0
|
167
|
-
Zone/Window Adjacency Daylighting Counts, PERIMETER_TOP_ZN_4 ZN,1,0
|
168
|
-
! <Zone/Window Adjacency Daylighting Matrix>, Zone Name, Number of Adjacent Zones with Windows,Adjacent Zone Names - 1st 100 (max)
|
169
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_BOT_ZN_1 ZN,0
|
170
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_BOT_ZN_2 ZN,0
|
171
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_BOT_ZN_3 ZN,0
|
172
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_BOT_ZN_4 ZN,0
|
173
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_MID_ZN_1 ZN,0
|
174
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_MID_ZN_2 ZN,0
|
175
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_MID_ZN_3 ZN,0
|
176
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_MID_ZN_4 ZN,0
|
177
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_TOP_ZN_1 ZN,0
|
178
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_TOP_ZN_2 ZN,0
|
179
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_TOP_ZN_3 ZN,0
|
180
|
-
Zone/Window Adjacency Daylighting Matrix, PERIMETER_TOP_ZN_4 ZN,0
|
181
|
-
! <Water Heater Information>,Type,Name,Volume {m3},Maximum Capacity {W},Standard Rated Recovery Efficiency, Standard Rated Energy Factor
|
182
|
-
! <ZoneInfiltration Airflow Stats Nominal>,Name,Schedule Name,Zone Name, Zone Floor Area {m2}, # Zone Occupants,Design Volume Flow Rate {m3/s},Volume Flow Rate/Floor Area {m3/s-m2},Volume Flow Rate/Exterior Surface Area {m3/s-m2},ACH - Air Changes per Hour,Equation A - Constant Term Coefficient {},Equation B - Temperature Term Coefficient {1/C},Equation C - Velocity Term Coefficient {s/m}, Equation D - Velocity Squared Term Coefficient {s2/m2}
|
183
|
-
ZoneInfiltration Airflow Stats Nominal, FIRSTFLOOR_PLENUM INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,FIRSTFLOOR_PLENUM ZN,1660.73,0.0,0.116,6.957E-005,5.696E-004,0.205,0.000,0.000,0.224,0.000
|
184
|
-
ZoneInfiltration Airflow Stats Nominal, MIDFLOOR_PLENUM INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,MIDFLOOR_PLENUM ZN,1660.73,0.0,0.116,6.957E-005,5.696E-004,0.205,0.000,0.000,0.224,0.000
|
185
|
-
ZoneInfiltration Airflow Stats Nominal, ENTRY DOOR INFILTRATION,OFFICEMEDIUM INFIL_DOOR_OPENING_SCH,PERIMETER_BOT_ZN_1 ZN,207.34,11.2,0.679,3.273E-003,4.819E-003,4.296,1.000,0.000,0.000,0.000
|
186
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_BOT_ZN_1 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_BOT_ZN_1 ZN,207.34,11.2,8.021E-002,3.868E-004,5.696E-004,0.508,0.000,0.000,0.224,0.000
|
187
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_BOT_ZN_2 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_BOT_ZN_2 ZN,131.26,7.1,5.310E-002,4.045E-004,5.696E-004,0.531,0.000,0.000,0.224,0.000
|
188
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_BOT_ZN_3 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_BOT_ZN_3 ZN,207.34,11.2,8.021E-002,3.868E-004,5.696E-004,0.508,0.000,0.000,0.224,0.000
|
189
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_BOT_ZN_4 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_BOT_ZN_4 ZN,131.25,7.1,5.310E-002,4.046E-004,5.696E-004,0.531,0.000,0.000,0.224,0.000
|
190
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_MID_ZN_1 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_MID_ZN_1 ZN,207.34,11.2,7.798E-002,3.761E-004,5.696E-004,0.494,0.000,0.000,0.224,0.000
|
191
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_MID_ZN_2 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_MID_ZN_2 ZN,131.26,7.1,5.199E-002,3.961E-004,5.696E-004,0.520,0.000,0.000,0.224,0.000
|
192
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_MID_ZN_3 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_MID_ZN_3 ZN,207.34,11.2,7.798E-002,3.761E-004,5.696E-004,0.494,0.000,0.000,0.224,0.000
|
193
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_MID_ZN_4 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_MID_ZN_4 ZN,131.25,7.1,5.199E-002,3.961E-004,5.696E-004,0.520,0.000,0.000,0.224,0.000
|
194
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_TOP_ZN_1 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_TOP_ZN_1 ZN,207.34,11.2,7.798E-002,3.761E-004,5.696E-004,0.494,0.000,0.000,0.224,0.000
|
195
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_TOP_ZN_2 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_TOP_ZN_2 ZN,131.26,7.1,5.199E-002,3.961E-004,5.696E-004,0.520,0.000,0.000,0.224,0.000
|
196
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_TOP_ZN_3 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_TOP_ZN_3 ZN,207.34,11.2,7.798E-002,3.761E-004,5.696E-004,0.494,0.000,0.000,0.224,0.000
|
197
|
-
ZoneInfiltration Airflow Stats Nominal, PERIMETER_TOP_ZN_4 INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,PERIMETER_TOP_ZN_4 ZN,131.25,7.1,5.199E-002,3.961E-004,5.696E-004,0.520,0.000,0.000,0.224,0.000
|
198
|
-
ZoneInfiltration Airflow Stats Nominal, TOPFLOOR_PLENUM INFILTRATION,OFFICEMEDIUM INFIL_SCH_PNNL,TOPFLOOR_PLENUM ZN,1660.73,0.0,0.116,6.957E-005,6.199E-005,0.205,0.000,0.000,0.224,0.000
|
199
|
-
! <AirFlow Model>, Simple
|
200
|
-
AirFlow Model, Simple
|
201
|
-
! <RoomAir Model>, Zone Name, Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined
|
202
|
-
RoomAir Model,CORE_BOTTOM ZN,Mixing/Well-Stirred
|
203
|
-
RoomAir Model,CORE_MID ZN,Mixing/Well-Stirred
|
204
|
-
RoomAir Model,CORE_TOP ZN,Mixing/Well-Stirred
|
205
|
-
RoomAir Model,FIRSTFLOOR_PLENUM ZN,Mixing/Well-Stirred
|
206
|
-
RoomAir Model,MIDFLOOR_PLENUM ZN,Mixing/Well-Stirred
|
207
|
-
RoomAir Model,PERIMETER_BOT_ZN_1 ZN,Mixing/Well-Stirred
|
208
|
-
RoomAir Model,PERIMETER_BOT_ZN_2 ZN,Mixing/Well-Stirred
|
209
|
-
RoomAir Model,PERIMETER_BOT_ZN_3 ZN,Mixing/Well-Stirred
|
210
|
-
RoomAir Model,PERIMETER_BOT_ZN_4 ZN,Mixing/Well-Stirred
|
211
|
-
RoomAir Model,PERIMETER_MID_ZN_1 ZN,Mixing/Well-Stirred
|
212
|
-
RoomAir Model,PERIMETER_MID_ZN_2 ZN,Mixing/Well-Stirred
|
213
|
-
RoomAir Model,PERIMETER_MID_ZN_3 ZN,Mixing/Well-Stirred
|
214
|
-
RoomAir Model,PERIMETER_MID_ZN_4 ZN,Mixing/Well-Stirred
|
215
|
-
RoomAir Model,PERIMETER_TOP_ZN_1 ZN,Mixing/Well-Stirred
|
216
|
-
RoomAir Model,PERIMETER_TOP_ZN_2 ZN,Mixing/Well-Stirred
|
217
|
-
RoomAir Model,PERIMETER_TOP_ZN_3 ZN,Mixing/Well-Stirred
|
218
|
-
RoomAir Model,PERIMETER_TOP_ZN_4 ZN,Mixing/Well-Stirred
|
219
|
-
RoomAir Model,TOPFLOOR_PLENUM ZN,Mixing/Well-Stirred
|
220
|
-
! <AirflowNetwork Model:Control>, No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation
|
221
|
-
AirflowNetwork Model:Control,NoMultizoneOrDistribution
|
222
|
-
! <Zone Volume Capacitance Multiplier>, Sensible Heat Capacity Multiplier, Moisture Capacity Multiplier, Carbon Dioxide Capacity Multiplier, Generic Contaminant Capacity Multiplier
|
223
|
-
Zone Volume Capacitance Multiplier, 1.000 , 1.000, 1.000, 1.000
|
224
|
-
! <Load Timesteps in Zone Design Calculation Averaging Window>, Value
|
225
|
-
Load Timesteps in Zone Design Calculation Averaging Window, 6
|
226
|
-
! <Heating Sizing Factor Information>, Sizing Factor ID, Value
|
227
|
-
Heating Sizing Factor Information, Global, 1.0000
|
228
|
-
! <Cooling Sizing Factor Information>, Sizing Factor ID, Value
|
229
|
-
Cooling Sizing Factor Information, Global, 1.0000
|
230
|
-
! <Sky Daylight Factors>, MonthAndDay, Zone Name, Window Name, Reference Point, Daylight Factor
|
231
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 1,6.5144E-002
|
232
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 2,6.4887E-002
|
233
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 1,6.3243E-002
|
234
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 2,6.2703E-002
|
235
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 1,5.1630E-002
|
236
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 2,5.1204E-002
|
237
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 1,4.5104E-002
|
238
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_1 ZN,PERIMETER_BOT_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_BOT_ZN_1 DAYLT SENSOR 2,4.5295E-002
|
239
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 1,4.6140E-002
|
240
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 2,4.5176E-002
|
241
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 1,4.1085E-002
|
242
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 2,4.0219E-002
|
243
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 1,3.3902E-002
|
244
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 2,3.3338E-002
|
245
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 1,4.5679E-002
|
246
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_2 ZN,PERIMETER_BOT_ZN_2_WALL_EAST_WINDOW,PERIMETER_BOT_ZN_2 DAYLT SENSOR 2,4.5198E-002
|
247
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 1,3.6907E-002
|
248
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 2,3.6394E-002
|
249
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 1,3.0917E-002
|
250
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 2,3.0504E-002
|
251
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 1,2.3174E-002
|
252
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 2,2.2967E-002
|
253
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 1,4.5295E-002
|
254
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_3 ZN,PERIMETER_BOT_ZN_3_WALL_NORTH_WINDOW,PERIMETER_BOT_ZN_3 DAYLT SENSOR 2,4.5103E-002
|
255
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 1,4.6763E-002
|
256
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 2,4.6129E-002
|
257
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 1,4.1788E-002
|
258
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 2,4.1294E-002
|
259
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 1,3.4541E-002
|
260
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 2,3.4307E-002
|
261
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 1,4.5679E-002
|
262
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_BOT_ZN_4 ZN,PERIMETER_BOT_ZN_4_WALL_WEST_WINDOW,PERIMETER_BOT_ZN_4 DAYLT SENSOR 2,4.5186E-002
|
263
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 1,6.3343E-002
|
264
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 2,6.3086E-002
|
265
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 1,6.1514E-002
|
266
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 2,6.0974E-002
|
267
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 1,5.0320E-002
|
268
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 2,4.9894E-002
|
269
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 1,4.4108E-002
|
270
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_1 ZN,PERIMETER_MID_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_MID_ZN_1 DAYLT SENSOR 2,4.4300E-002
|
271
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 1,4.5078E-002
|
272
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 2,4.4114E-002
|
273
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 1,4.0190E-002
|
274
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 2,3.9324E-002
|
275
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 1,3.3276E-002
|
276
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 2,3.2712E-002
|
277
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 1,4.4788E-002
|
278
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_2 ZN,PERIMETER_MID_ZN_2_WALL_EAST_WINDOW,PERIMETER_MID_ZN_2 DAYLT SENSOR 2,4.4307E-002
|
279
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 1,3.6020E-002
|
280
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 2,3.5507E-002
|
281
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 1,3.0244E-002
|
282
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 2,2.9832E-002
|
283
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 1,2.2805E-002
|
284
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 2,2.2597E-002
|
285
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 1,4.4300E-002
|
286
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_3 ZN,PERIMETER_MID_ZN_3_WALL_NORTH_WINDOW,PERIMETER_MID_ZN_3 DAYLT SENSOR 2,4.4107E-002
|
287
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 1,4.5682E-002
|
288
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 2,4.5048E-002
|
289
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 1,4.0870E-002
|
290
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 2,4.0376E-002
|
291
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 1,3.3895E-002
|
292
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 2,3.3660E-002
|
293
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 1,4.4788E-002
|
294
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_MID_ZN_4 ZN,PERIMETER_MID_ZN_4_WALL_WEST_WINDOW,PERIMETER_MID_ZN_4 DAYLT SENSOR 2,4.4295E-002
|
295
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 1,6.3339E-002
|
296
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 2,6.3082E-002
|
297
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 1,6.1510E-002
|
298
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 2,6.0970E-002
|
299
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 1,5.0315E-002
|
300
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 2,4.9889E-002
|
301
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 1,4.4104E-002
|
302
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_1 ZN,PERIMETER_TOP_ZN_1_WALL_SOUTH_WINDOW,PERIMETER_TOP_ZN_1 DAYLT SENSOR 2,4.4296E-002
|
303
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 1,4.5077E-002
|
304
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 2,4.4113E-002
|
305
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 1,4.0188E-002
|
306
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 2,3.9322E-002
|
307
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 1,3.3273E-002
|
308
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 2,3.2709E-002
|
309
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 1,4.4784E-002
|
310
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_2 ZN,PERIMETER_TOP_ZN_2_WALL_EAST_WINDOW,PERIMETER_TOP_ZN_2 DAYLT SENSOR 2,4.4303E-002
|
311
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 1,3.6020E-002
|
312
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 2,3.5507E-002
|
313
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 1,3.0244E-002
|
314
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 2,2.9832E-002
|
315
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 1,2.2803E-002
|
316
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 2,2.2596E-002
|
317
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 1,4.4296E-002
|
318
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_3 ZN,PERIMETER_TOP_ZN_3_WALL_NORTH_WINDOW,PERIMETER_TOP_ZN_3 DAYLT SENSOR 2,4.4103E-002
|
319
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 1,4.5681E-002
|
320
|
-
Sky Daylight Factors,Clear Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 2,4.5046E-002
|
321
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 1,4.0868E-002
|
322
|
-
Sky Daylight Factors,Clear Turbid Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 2,4.0374E-002
|
323
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 1,3.3892E-002
|
324
|
-
Sky Daylight Factors,Intermediate Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 2,3.3657E-002
|
325
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 1,4.4784E-002
|
326
|
-
Sky Daylight Factors,Overcast Sky,07/21,PERIMETER_TOP_ZN_4 ZN,PERIMETER_TOP_ZN_4_WALL_WEST_WINDOW,PERIMETER_TOP_ZN_4 DAYLT SENSOR 2,4.4291E-002
|
327
|
-
! <Zone Sizing Information>, Zone Name, Load Type, Calc Des Load {W}, User Des Load {W}, Calc Des Air Flow Rate {m3/s}, User Des Air Flow Rate {m3/s}, Design Day Name, Date/Time of Peak, Temperature at Peak {C}, Humidity Ratio at Peak {kgWater/kgDryAir}, Floor Area {m2}, # Occupants, Calc Outdoor Air Flow Rate {m3/s}, Calc DOAS Heat Addition Rate {W}
|
328
|
-
Zone Sizing Information, CORE_BOTTOM ZN, Cooling, 53584.14878, 53584.14878, 3.94846, 3.94846, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 08:00:00, 23.41800, 1.33548E-002, 983.53657, 52.93350, 0.42469, 0.00000
|
329
|
-
Zone Sizing Information, CORE_BOTTOM ZN, Heating, 9940.79936, 9940.79936, 0.28609, 0.42469, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:20:00, -16.30000, 9.24091E-004, 983.53657, 52.93350, 0.42469, 0.00000
|
330
|
-
Zone Sizing Information, CORE_MID ZN, Cooling, 32563.15528, 32563.15528, 2.39604, 2.39604, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 08:00:00, 23.41800, 1.33548E-002, 983.53657, 52.93350, 0.42469, 0.00000
|
331
|
-
Zone Sizing Information, CORE_MID ZN, Heating, 14665.01637, 14665.01637, 0.41820, 0.42469, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 983.53657, 52.93350, 0.42469, 0.00000
|
332
|
-
Zone Sizing Information, CORE_TOP ZN, Cooling, 32911.76910, 32911.76910, 2.42182, 2.42182, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 08:00:00, 23.41800, 1.33548E-002, 983.53657, 52.93350, 0.42469, 0.00000
|
333
|
-
Zone Sizing Information, CORE_TOP ZN, Heating, 27812.77010, 27812.77010, 0.79569, 0.79569, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 983.53657, 52.93350, 0.42469, 0.00000
|
334
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_1 ZN, Cooling, 10574.00391, 10574.00391, 0.78518, 0.78518, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 13:20:00, 29.99000, 1.33664E-002, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
335
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_1 ZN, Heating, 10356.10699, 10356.10699, 0.29670, 0.29670, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
336
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_2 ZN, Cooling, 9449.84825, 9449.84825, 0.70170, 0.70170, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 09:00:00, 25.18500, 1.33579E-002, 131.26219, 7.06447, 5.66790E-002, 0.00000
|
337
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_2 ZN, Heating, 6697.63615, 6697.63615, 0.19189, 0.19189, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 131.26219, 7.06447, 5.66790E-002, 0.00000
|
338
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_3 ZN, Cooling, 7110.56079, 7110.56079, 0.52801, 0.52801, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 14:30:00, 30.30000, 1.33670E-002, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
339
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_3 ZN, Heating, 10256.86473, 10256.86473, 0.29385, 0.29385, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
340
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_4 ZN, Cooling, 9684.58512, 9684.58512, 0.71914, 0.71914, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 17:20:00, 28.68800, 1.33641E-002, 131.25358, 7.06401, 5.66753E-002, 0.00000
|
341
|
-
Zone Sizing Information, PERIMETER_BOT_ZN_4 ZN, Heating, 6792.20797, 6792.20797, 0.19461, 0.19461, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 131.25358, 7.06401, 5.66753E-002, 0.00000
|
342
|
-
Zone Sizing Information, PERIMETER_MID_ZN_1 ZN, Cooling, 12146.78881, 12146.78881, 0.90198, 0.90198, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 13:00:00, 29.83500, 1.33661E-002, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
343
|
-
Zone Sizing Information, PERIMETER_MID_ZN_1 ZN, Heating, 9841.61425, 9841.61425, 0.28191, 0.28191, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
344
|
-
Zone Sizing Information, PERIMETER_MID_ZN_2 ZN, Cooling, 11736.22592, 11736.22592, 0.86538, 0.86538, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 08:00:00, 23.41800, 1.33548E-002, 131.26219, 7.06447, 5.66790E-002, 0.00000
|
345
|
-
Zone Sizing Information, PERIMETER_MID_ZN_2 ZN, Heating, 6382.61717, 6382.61717, 0.18284, 0.18284, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 131.26219, 7.06447, 5.66790E-002, 0.00000
|
346
|
-
Zone Sizing Information, PERIMETER_MID_ZN_3 ZN, Cooling, 8028.28476, 8028.28476, 0.59616, 0.59616, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 14:20:00, 30.30000, 1.33670E-002, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
347
|
-
Zone Sizing Information, PERIMETER_MID_ZN_3 ZN, Heating, 9709.52914, 9709.52914, 0.27812, 0.27812, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
348
|
-
Zone Sizing Information, PERIMETER_MID_ZN_4 ZN, Cooling, 11555.26100, 11555.26100, 0.85805, 0.85805, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 16:50:00, 29.12200, 1.33649E-002, 131.25358, 7.06401, 5.66753E-002, 0.00000
|
349
|
-
Zone Sizing Information, PERIMETER_MID_ZN_4 ZN, Heating, 6476.21341, 6476.21341, 0.18553, 0.18553, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 131.25358, 7.06401, 5.66753E-002, 0.00000
|
350
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_1 ZN, Cooling, 12586.01817, 12586.01817, 0.93460, 0.93460, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 13:00:00, 29.83500, 1.33661E-002, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
351
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_1 ZN, Heating, 12454.00101, 12454.00101, 0.35691, 0.35691, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
352
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_2 ZN, Cooling, 11760.25416, 11760.25416, 0.86716, 0.86716, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 08:00:00, 23.41800, 1.33548E-002, 131.26219, 7.06447, 5.66790E-002, 0.00000
|
353
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_2 ZN, Heating, 8034.24164, 8034.24164, 0.23025, 0.23025, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 131.26219, 7.06447, 5.66790E-002, 0.00000
|
354
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_3 ZN, Cooling, 8575.23553, 8575.23553, 0.63677, 0.63677, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 14:40:00, 30.30000, 1.33670E-002, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
355
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_3 ZN, Heating, 12348.45852, 12348.45852, 0.35388, 0.35388, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 207.33814, 11.15885, 8.95286E-002, 0.00000
|
356
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_4 ZN, Cooling, 11927.33697, 11927.33697, 0.88568, 0.88568, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 16:50:00, 29.12200, 1.33649E-002, 131.25358, 7.06401, 5.66753E-002, 0.00000
|
357
|
-
Zone Sizing Information, PERIMETER_TOP_ZN_4 ZN, Heating, 8130.68406, 8130.68406, 0.23302, 0.23302, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 08:00:00, -16.30000, 9.24091E-004, 131.25358, 7.06401, 5.66753E-002, 0.00000
|
358
|
-
! <System Sizing Information>, System Name, Load Type, Peak Load Kind, User Design Capacity, Calc Des Air Flow Rate [m3/s], User Des Air Flow Rate [m3/s], Design Day Name, Date/Time of Peak
|
359
|
-
System Sizing Information, 5 ZONE PVAV, Cooling, Sensible, 86864.88, 5.99399, 5.99399, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 00:00:00
|
360
|
-
System Sizing Information, 5 ZONE PVAV, Heating, Sensible, 40941.32, 1.40174, 1.40174, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 18:00:00
|
361
|
-
System Sizing Information, 5 ZONE PVAV 1, Cooling, Sensible, 69683.61, 4.75782, 4.75782, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 00:00:00
|
362
|
-
System Sizing Information, 5 ZONE PVAV 1, Heating, Sensible, 41063.28, 1.35309, 1.35309, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 12:00:00
|
363
|
-
System Sizing Information, 5 ZONE PVAV 2, Cooling, Sensible, 73974.66, 4.90984, 4.90984, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB, 7/21 00:00:00
|
364
|
-
System Sizing Information, 5 ZONE PVAV 2, Heating, Sensible, 40935.59, 1.96975, 1.96975, BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB, 1/21 06:10:00
|
365
|
-
! <Component Sizing Information>, Component Type, Component Name, Input Field Description, Value
|
366
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_BOTTOM ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 3.94846
|
367
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_BOTTOM ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.18981
|
368
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_BOTTOM ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.21461
|
369
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_BOTTOM ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.84737
|
370
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_BOTTOM ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 8.61557E-004
|
371
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_BOTTOM ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.21461
|
372
|
-
Component Sizing Information, Coil:Heating:Electric, CORE_BOTTOM ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 37819.78785
|
373
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_MID ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 2.39604
|
374
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_MID ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.31279
|
375
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_MID ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.21079
|
376
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_MID ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.50506
|
377
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_MID ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 5.13513E-004
|
378
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_MID ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.21079
|
379
|
-
Component Sizing Information, Coil:Heating:Electric, CORE_MID ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 22541.67539
|
380
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_TOP ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 2.42182
|
381
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_TOP ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.30946
|
382
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_TOP ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20642
|
383
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_TOP ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.49991
|
384
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_TOP ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 5.08280E-004
|
385
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, CORE_TOP ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20642
|
386
|
-
Component Sizing Information, Coil:Heating:Electric, CORE_TOP ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 35513.04782
|
387
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_1 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.78518
|
388
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_1 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.20122
|
389
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_1 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20268
|
390
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_1 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.15914
|
391
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_1 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 7.67548E-004
|
392
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_1 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20268
|
393
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_BOT_ZN_1 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 13242.14897
|
394
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_2 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.70170
|
395
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_2 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.14254
|
396
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_2 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20000
|
397
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_2 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.14034
|
398
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_2 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 1.06916E-003
|
399
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_2 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20000
|
400
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_BOT_ZN_2 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 8564.48910
|
401
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_3 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.52801
|
402
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_3 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.29922
|
403
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_3 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.30066
|
404
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_3 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.15875
|
405
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_3 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 7.65661E-004
|
406
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_3 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.30066
|
407
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_BOT_ZN_3 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 13114.99353
|
408
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_4 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.71914
|
409
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_4 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.13908
|
410
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_4 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20000
|
411
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_4 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.14383
|
412
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_4 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 1.09580E-003
|
413
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_BOT_ZN_4 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20000
|
414
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_BOT_ZN_4 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 8685.67827
|
415
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_1 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.90198
|
416
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_1 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.17516
|
417
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_1 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.21079
|
418
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_1 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.19013
|
419
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_1 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 9.16987E-004
|
420
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_1 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.21079
|
421
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_MID_ZN_1 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 12582.29944
|
422
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_2 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.86538
|
423
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_2 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.11558
|
424
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_2 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.21079
|
425
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_2 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.18241
|
426
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_2 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 1.38968E-003
|
427
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_2 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.21079
|
428
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_MID_ZN_2 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 8160.44735
|
429
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_3 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.59616
|
430
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_3 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.26502
|
431
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_3 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.21079
|
432
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_3 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.12566
|
433
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_3 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 6.06076E-004
|
434
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_3 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.21079
|
435
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_MID_ZN_3 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 12413.05743
|
436
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_4 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.85805
|
437
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_4 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.11656
|
438
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_4 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.21079
|
439
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_4 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.18087
|
440
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_4 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 1.37799E-003
|
441
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_MID_ZN_4 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.21079
|
442
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_MID_ZN_4 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 8280.38242
|
443
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_1 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.93460
|
444
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_1 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.16905
|
445
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_1 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20642
|
446
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_1 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.19292
|
447
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_1 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 9.30457E-004
|
448
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_1 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20642
|
449
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_TOP_ZN_1 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 15929.38173
|
450
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_2 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.86716
|
451
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_2 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.11534
|
452
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_2 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20642
|
453
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_2 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.17900
|
454
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_2 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 1.36368E-003
|
455
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_2 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20642
|
456
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_TOP_ZN_2 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 10276.55800
|
457
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_3 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.63677
|
458
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_3 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.24811
|
459
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_3 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20642
|
460
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_3 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.13144
|
461
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_3 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 6.33952E-004
|
462
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_3 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20642
|
463
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_TOP_ZN_3 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 15794.15252
|
464
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_4 ZN VAV TERMINAL, Design Size Maximum Air Flow Rate [m3/s], 0.88568
|
465
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_4 ZN VAV TERMINAL, Design Size Constant Minimum Air Flow Fraction, 0.11292
|
466
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_4 ZN VAV TERMINAL, User-Specified Constant Minimum Air Flow Fraction, 0.20642
|
467
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_4 ZN VAV TERMINAL, Design Size Minimum Air Flow Rate [m3/s], 0.18282
|
468
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_4 ZN VAV TERMINAL, Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2], 1.39289E-003
|
469
|
-
Component Sizing Information, AirTerminal:SingleDuct:VAV:Reheat, PERIMETER_TOP_ZN_4 ZN VAV TERMINAL, Design Size Maximum Flow Fraction during Reheat [], 0.20642
|
470
|
-
Component Sizing Information, Coil:Heating:Electric, PERIMETER_TOP_ZN_4 ZN ELECTRIC REHEAT COIL, Design Size Nominal Capacity [W], 10400.13695
|
471
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Sum of Air Terminal Maximum Heating Flow Rates [m3/s], 1.44943
|
472
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Sum of Air Terminal Minimum Heating Flow Rates [m3/s], 1.44943
|
473
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Sum of Air Terminal Maximum Flow Rates [m3/s], 6.68249
|
474
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Adjusted Heating Design Air Flow Rate [m3/s], 1.44943
|
475
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Adjusted Cooling Design Air Flow Rate [m3/s], 5.99399
|
476
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Adjusted Main Design Air Flow Rate [m3/s], 5.99399
|
477
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, User Heating Air Flow Ratio [], 0.30000
|
478
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Calculated Heating Air Flow Ratio [], 0.24181
|
479
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Sum of Air Terminal Maximum Heating Flow Rates [m3/s], 1.18413
|
480
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Sum of Air Terminal Minimum Heating Flow Rates [m3/s], 1.18413
|
481
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Sum of Air Terminal Maximum Flow Rates [m3/s], 5.61760
|
482
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Adjusted Heating Design Air Flow Rate [m3/s], 1.35309
|
483
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Adjusted Cooling Design Air Flow Rate [m3/s], 4.75782
|
484
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Adjusted Main Design Air Flow Rate [m3/s], 4.75782
|
485
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, User Heating Air Flow Ratio [], 0.30000
|
486
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Calculated Heating Air Flow Ratio [], 0.28439
|
487
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Sum of Air Terminal Maximum Heating Flow Rates [m3/s], 1.18609
|
488
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Sum of Air Terminal Minimum Heating Flow Rates [m3/s], 1.18609
|
489
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Sum of Air Terminal Maximum Flow Rates [m3/s], 5.74603
|
490
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Adjusted Heating Design Air Flow Rate [m3/s], 1.96975
|
491
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Adjusted Cooling Design Air Flow Rate [m3/s], 4.90984
|
492
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Adjusted Main Design Air Flow Rate [m3/s], 4.90984
|
493
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, User Heating Air Flow Ratio [], 0.30000
|
494
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Calculated Heating Air Flow Ratio [], 0.40118
|
495
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV, Design Supply Air Flow Rate [m3/s], 5.99399
|
496
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 1, Design Supply Air Flow Rate [m3/s], 4.75782
|
497
|
-
Component Sizing Information, AirLoopHVAC, 5 ZONE PVAV 2, Design Supply Air Flow Rate [m3/s], 4.90984
|
498
|
-
!<Controller:MechanicalVentilation>,Name,Availability Schedule Name,Demand Controlled Ventilation {Yes/No},System Outdoor Air Method,Zone Maximum Outdoor Air Fraction,Number of Zones,Zone Name,DSOA Name,DSZAD Name
|
499
|
-
Controller:MechanicalVentilation,5 ZONE PVAV VENTILATION CONTROLLER,OFFICEMEDIUM MINOA_MOTORIZEDDAMPER_SCHED,Yes,VentilationRateProcedure,1.00,5,CORE_BOTTOM ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_BOT_ZN_1 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_BOT_ZN_2 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_BOT_ZN_3 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_BOT_ZN_4 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,
|
500
|
-
Controller:MechanicalVentilation,5 ZONE PVAV 1 VENTILATION CONTROLLER,OFFICEMEDIUM MINOA_MOTORIZEDDAMPER_SCHED,Yes,VentilationRateProcedure,1.00,5,CORE_MID ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_MID_ZN_1 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_MID_ZN_2 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_MID_ZN_3 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_MID_ZN_4 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,
|
501
|
-
Controller:MechanicalVentilation,5 ZONE PVAV 2 VENTILATION CONTROLLER,OFFICEMEDIUM MINOA_MOTORIZEDDAMPER_SCHED,Yes,VentilationRateProcedure,1.00,5,CORE_TOP ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_TOP_ZN_1 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_TOP_ZN_2 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_TOP_ZN_3 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,,PERIMETER_TOP_ZN_4 ZN,OFFICE WHOLEBUILDING - MD OFFICE VENTILATION,
|
502
|
-
Component Sizing Information, Controller:OutdoorAir, CONTROLLER OUTDOOR AIR 1, Maximum Outdoor Air Flow Rate [m3/s], 5.99399
|
503
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER, Design Size High Speed Rated Air Flow Rate [m3/s], 5.99399
|
504
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER, Design Size High Speed Gross Rated Total Cooling Capacity [W], 123149.60966
|
505
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER, Design Size High Speed Rated Sensible Heat Ratio, 0.76522
|
506
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER, Design Size Low Speed Rated Air Flow Rate [m3/s], 1.99780
|
507
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER, Design Size Low Speed Gross Rated Total Cooling Capacity [W], 41045.76490
|
508
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER, Design Size Low Speed Gross Rated Sensible Heat Ratio, 0.76522
|
509
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER, User-Specified Low Speed Gross Rated Sensible Heat Ratio, 0.69000
|
510
|
-
Component Sizing Information, Fan:VariableVolume, 5 ZONE PVAV FAN, Design Size Maximum Flow Rate [m3/s], 5.99399
|
511
|
-
! <VAV DX Cooling Coil Standard Rating Information>, DX Coil Type, DX Coil Name, Fan Type, Fan Name, Standard Net Cooling Capacity {W}, Standard Net Cooling Capacity {Btu/h}, IEER {Btu/W-h}, COP 100% Capacity {W/W}, COP 75% Capacity {W/W}, COP 50% Capacity {W/W}, COP 25% Capacity {W/W}, EER 100% Capacity {Btu/W-h}, EER 75% Capacity {Btu/W-h}, EER 50% Capacity {Btu/W-h}, EER 25% Capacity {Btu/W-h}, Supply Air Flow 100% {kg/s}, Supply Air Flow 75% {kg/s},Supply Air Flow 50% {kg/s},Supply Air Flow 25% {kg/s}
|
512
|
-
VAV DX Cooling Coil Standard Rating Information, Coil:Cooling:DX:TwoSpeed,5 ZONE PVAV 2SPD DX CLG COIL 376KBTU/HR 9.8EER,Fan:VariableVolume,5 ZONE PVAV FAN,122135.58,416743.89,11.39,2.76,3.27,3.48,3.50,9.43,11.15,11.87,11.96,6.7699,5.0382,3.1905,1.4390,
|
513
|
-
Component Sizing Information, Coil:Heating:Fuel, 5 ZONE PVAV MAIN GAS HTG COIL, Design Size Nominal Capacity [W], 35205.66694
|
514
|
-
Component Sizing Information, Controller:OutdoorAir, CONTROLLER OUTDOOR AIR 2, Maximum Outdoor Air Flow Rate [m3/s], 4.75782
|
515
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 1 2SPD DX CLG COIL 310KBTU/HR 9.8EER, Design Size High Speed Rated Air Flow Rate [m3/s], 4.75782
|
516
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 1 2SPD DX CLG COIL 310KBTU/HR 9.8EER, Design Size High Speed Gross Rated Total Cooling Capacity [W], 103342.52336
|
517
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 1 2SPD DX CLG COIL 310KBTU/HR 9.8EER, Design Size High Speed Rated Sensible Heat Ratio, 0.74520
|
518
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 1 2SPD DX CLG COIL 310KBTU/HR 9.8EER, Design Size Low Speed Rated Air Flow Rate [m3/s], 1.58578
|
519
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 1 2SPD DX CLG COIL 310KBTU/HR 9.8EER, Design Size Low Speed Gross Rated Total Cooling Capacity [W], 34444.06304
|
520
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 1 2SPD DX CLG COIL 310KBTU/HR 9.8EER, User-Specified Low Speed Gross Rated Sensible Heat Ratio, 0.69000
|
521
|
-
Component Sizing Information, Fan:VariableVolume, 5 ZONE PVAV 1 FAN, Design Size Maximum Flow Rate [m3/s], 4.75782
|
522
|
-
VAV DX Cooling Coil Standard Rating Information, Coil:Cooling:DX:TwoSpeed,5 ZONE PVAV 1 2SPD DX CLG COIL 310KBTU/HR 9.8EER,Fan:VariableVolume,5 ZONE PVAV 1 FAN,102352.93,349242.70,11.42,2.81,3.28,3.48,3.51,9.59,11.20,11.87,11.97,5.3737,4.0592,2.5980,1.1703,
|
523
|
-
Component Sizing Information, Coil:Heating:Fuel, 5 ZONE PVAV 1 MAIN GAS HTG COIL, Design Size Nominal Capacity [W], 38808.46856
|
524
|
-
Component Sizing Information, Controller:OutdoorAir, CONTROLLER OUTDOOR AIR 3, Maximum Outdoor Air Flow Rate [m3/s], 4.90984
|
525
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2 2SPD DX CLG COIL 327KBTU/HR 9.8EER, Design Size High Speed Rated Air Flow Rate [m3/s], 4.90984
|
526
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2 2SPD DX CLG COIL 327KBTU/HR 9.8EER, Design Size High Speed Gross Rated Total Cooling Capacity [W], 105034.19600
|
527
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2 2SPD DX CLG COIL 327KBTU/HR 9.8EER, Design Size High Speed Rated Sensible Heat Ratio, 0.75049
|
528
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2 2SPD DX CLG COIL 327KBTU/HR 9.8EER, Design Size Low Speed Rated Air Flow Rate [m3/s], 1.63645
|
529
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2 2SPD DX CLG COIL 327KBTU/HR 9.8EER, Design Size Low Speed Gross Rated Total Cooling Capacity [W], 35007.89753
|
530
|
-
Component Sizing Information, Coil:Cooling:DX:TwoSpeed, 5 ZONE PVAV 2 2SPD DX CLG COIL 327KBTU/HR 9.8EER, User-Specified Low Speed Gross Rated Sensible Heat Ratio, 0.69000
|
531
|
-
Component Sizing Information, Fan:VariableVolume, 5 ZONE PVAV 2 FAN, Design Size Maximum Flow Rate [m3/s], 4.90984
|
532
|
-
VAV DX Cooling Coil Standard Rating Information, Coil:Cooling:DX:TwoSpeed,5 ZONE PVAV 2 2SPD DX CLG COIL 327KBTU/HR 9.8EER,Fan:VariableVolume,5 ZONE PVAV 2 FAN,104007.92,354889.74,11.40,2.79,3.27,3.48,3.51,9.51,11.16,11.86,11.96,5.5454,4.1707,2.6610,1.1995,
|
533
|
-
Component Sizing Information, Coil:Heating:Fuel, 5 ZONE PVAV 2 MAIN GAS HTG COIL, Design Size Nominal Capacity [W], 39409.88472
|
534
|
-
Water Heater Information,WaterHeater:Mixed,100GAL NATURAL GAS WATER HEATER - 100KBTU/HR 0.808 THERM EFF,0.3785,29307.1,0.973,0.1701
|
535
|
-
Component Sizing Information, PlantLoop, MAIN SERVICE WATER LOOP, Initial Maximum Loop Flow Rate [m3/s], 5.36265E-005
|
536
|
-
Component Sizing Information, PlantLoop, MAIN SERVICE WATER LOOP, Initial Plant Loop Volume [m3], 6.43518E-003
|
537
|
-
Component Sizing Information, Pump:ConstantSpeed, MAIN SERVICE WATER LOOP CIRCULATOR PUMP, Initial Design Flow Rate [m3/s], 5.36265E-005
|
538
|
-
Component Sizing Information, Pump:ConstantSpeed, MAIN SERVICE WATER LOOP CIRCULATOR PUMP, Initial Design Power Consumption [W], 2.40358
|
539
|
-
Component Sizing Information, WaterHeater:Mixed, 100GAL NATURAL GAS WATER HEATER - 100KBTU/HR 0.808 THERM EFF, Initial Use Side Design Flow Rate [m3/s], 5.36265E-005
|
540
|
-
! <Environment>,Environment Name,Environment Type, Start Date, End Date, Start DayOfWeek, Duration {#days}, Source:Start DayOfWeek, Use Daylight Saving, Use Holidays, Apply Weekend Holiday Rule, Use Rain Values, Use Snow Values, Sky Temperature Model
|
541
|
-
! <Environment:Special Days>, Special Day Name, Special Day Type, Source, Start Date, Duration {#days}
|
542
|
-
! <Environment:Daylight Saving>, Daylight Saving Indicator, Source, Start Date, End Date
|
543
|
-
! <Environment:WarmupDays>, NumberofWarmupDays
|
544
|
-
Environment,RUN PERIOD 1,WeatherFileRunPeriod,01/01/2006,12/31/2006,Sunday,365,Use RunPeriod Specified Day,No,No,No,Yes,Yes,Clark and Allen
|
545
|
-
Environment:Daylight Saving,Yes,InputFile,03/12,11/05
|
546
|
-
! <Environment:Design Day Data>, Max Dry-Bulb Temp {C}, Temp Range {dC}, Temp Range Ind Type, Hum Ind Type, Hum Ind Value at Max Temp, Hum Ind Units, Pressure {Pa}, Wind Direction {deg CW from N}, Wind Speed {m/s}, Clearness, Rain, Snow
|
547
|
-
! <Environment:Design Day Misc>,DayOfYear,ASHRAE A Coeff,ASHRAE B Coeff,ASHRAE C Coeff,Solar Constant-Annual Variation,Eq of Time {minutes}, Solar Declination Angle {deg}, Solar Model
|
548
|
-
Environment:Design Day Data,30.30,9.30,DefaultMultipliers,Wetbulb,21.80,{C},98769,240,5.7,0.00,No,No
|
549
|
-
Environment:Design Day Misc,202,1084.4,0.2082,0.1365,1.0,-6.23,20.6,ASHRAETau
|
550
|
-
Environment:WarmupDays, 6
|
551
|
-
! <Tabular Report>,Style,Unit Conversion
|
552
|
-
Tabular Report,HTML,None
|
553
|
-
! <Warmup Convergence Information>,Zone Name,Environment Type/Name,Average Warmup Temperature Difference {deltaC},Std Dev Warmup Temperature Difference {deltaC},Max Temperature Pass/Fail Convergence,Min Temperature Pass/Fail Convergence,Average Warmup Load Difference {W},Std Dev Warmup Load Difference {W},Heating Load Pass/Fail Convergence,Cooling Load Pass/Fail Convergence
|
554
|
-
Warmup Convergence Information,CORE_BOTTOM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.3468008555,0.6539890599,Pass,Pass,0.2420098730,0.4576479379,Pass,Pass
|
555
|
-
Warmup Convergence Information,CORE_MID ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1603787029,0.3074971579,Pass,Pass,0.1732831330,0.4025826321,Pass,Pass
|
556
|
-
Warmup Convergence Information,CORE_TOP ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1559339212,0.2983112091,Pass,Pass,0.1706048744,0.3925218211,Pass,Pass
|
557
|
-
Warmup Convergence Information,FIRSTFLOOR_PLENUM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,7.2846563996E-002,0.1046934162,Pass,Pass,0.5270464679,3.0357053899,Pass,Pass
|
558
|
-
Warmup Convergence Information,MIDFLOOR_PLENUM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,3.5792122215E-002,5.9544572535E-002,Pass,Pass,0.2171875033,0.4559218934,Pass,Pass
|
559
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_1 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1229094065,0.2355018074,Pass,Pass,0.1918660848,0.3798080037,Pass,Pass
|
560
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_2 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1850900946,0.3572140608,Pass,Pass,0.1881768779,0.3653660076,Pass,Pass
|
561
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_3 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1242700161,0.2278098679,Pass,Pass,0.1884363686,0.3753395115,Pass,Pass
|
562
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_4 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1661468902,0.3191940264,Pass,Pass,0.1957916509,0.3717703428,Pass,Pass
|
563
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_1 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1441213858,0.2805644463,Pass,Pass,0.1545694264,0.3362798261,Pass,Pass
|
564
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_2 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.2163493190,0.4242189100,Pass,Pass,0.1559876352,0.3360838824,Pass,Pass
|
565
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_3 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1255743860,0.2512777302,Pass,Pass,0.1529828696,0.3379733555,Pass,Pass
|
566
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_4 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1841188133,0.3528303094,Pass,Pass,0.1603311116,0.3370450143,Pass,Pass
|
567
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_1 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1430379735,0.2731382200,Pass,Pass,0.1549345898,0.3368911674,Pass,Pass
|
568
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_2 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.2116745187,0.4119043386,Pass,Pass,0.1562163147,0.3362999981,Pass,Pass
|
569
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_3 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1262559549,0.2485198489,Pass,Pass,0.1520562305,0.3371945187,Pass,Pass
|
570
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_4 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,0.1833466968,0.3466446625,Pass,Pass,0.1615881924,0.3377123992,Pass,Pass
|
571
|
-
Warmup Convergence Information,TOPFLOOR_PLENUM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1,4.0513107687E-002,5.2709894091E-002,Pass,Pass,0.8807543487,3.3512474097,Pass,Pass
|
572
|
-
Environment:Design Day Data,-16.30,0.00,DefaultMultipliers,Wetbulb,-16.30,{C},98769,270,5.1,0.00,No,No
|
573
|
-
Environment:Design Day Misc, 21,1229.0,0.1415,5.7310E-002,1.0,-11.15,-20.1,ASHRAEClearSky
|
574
|
-
Environment:WarmupDays, 10
|
575
|
-
Warmup Convergence Information,CORE_BOTTOM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.1078439739,0.2268519362,Pass,Pass,0.2918676642,0.4934881018,Pass,Pass
|
576
|
-
Warmup Convergence Information,CORE_MID ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.1144527618,0.2352314106,Pass,Pass,0.3554881595,0.7623613200,Pass,Pass
|
577
|
-
Warmup Convergence Information,CORE_TOP ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.1527502297,0.3016457486,Pass,Pass,0.4047160380,1.5903413490,Pass,Pass
|
578
|
-
Warmup Convergence Information,FIRSTFLOOR_PLENUM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,3.6769871002E-002,5.4885150473E-002,Pass,Pass,0.3222049370,0.9386473300,Pass,Pass
|
579
|
-
Warmup Convergence Information,MIDFLOOR_PLENUM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,4.3831739724E-002,6.3404048487E-002,Pass,Pass,0.3204827991,0.9427946948,Pass,Pass
|
580
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_1 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.3474765415,0.4981761630,Pass,Pass,0.2484286813,0.4313169778,Pass,Pass
|
581
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_2 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.3874503489,0.6039758430,Pass,Pass,0.2718234176,0.5159491608,Pass,Pass
|
582
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_3 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.3423819033,0.4926572070,Pass,Pass,0.2488188412,0.4350762548,Pass,Pass
|
583
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_4 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.3958305097,0.6170818453,Pass,Pass,0.2716562332,0.5141537078,Pass,Pass
|
584
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_1 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.3743210159,0.5345568177,Pass,Pass,0.2654080821,0.4949308948,Pass,Pass
|
585
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_2 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.4308703159,0.7010050022,Pass,Pass,0.3006424845,0.7735128866,Pass,Pass
|
586
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_3 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.3259606333,0.4349183667,Pass,Pass,0.2726908692,0.4522398553,Pass,Pass
|
587
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_4 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.4351969820,0.7006596288,Pass,Pass,0.3240622469,1.0394263189,Pass,Pass
|
588
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_1 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.4537814376,0.6298588489,Pass,Pass,0.2664853417,0.4482798800,Pass,Pass
|
589
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_2 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.5173882076,0.7746519368,Pass,Pass,0.2618069411,0.4652053271,Pass,Pass
|
590
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_3 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.3732112437,0.4878821004,Pass,Pass,0.2505194279,0.4316748669,Pass,Pass
|
591
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_4 ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.5261482399,0.7886375429,Pass,Pass,0.2621148660,0.4647305235,Pass,Pass
|
592
|
-
Warmup Convergence Information,TOPFLOOR_PLENUM ZN,SizingPeriod: BUFFALO.NIAGARA.INTL.AP_NY_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1,0.1020507143,0.1309338430,Pass,Pass,0.2568802057,0.4389782588,Pass,Pass
|
593
|
-
Environment:Design Day Data,30.30,9.30,DefaultMultipliers,Wetbulb,21.80,{C},98769,240,5.7,0.00,No,No
|
594
|
-
Environment:Design Day Misc,202,1084.4,0.2082,0.1365,1.0,-6.23,20.6,ASHRAETau
|
595
|
-
Component Sizing Information, PlantLoop, MAIN SERVICE WATER LOOP, Maximum Loop Flow Rate [m3/s], 5.36265E-005
|
596
|
-
Component Sizing Information, PlantLoop, MAIN SERVICE WATER LOOP, Plant Loop Volume [m3], 6.43518E-003
|
597
|
-
Component Sizing Information, WaterHeater:Mixed, 100GAL NATURAL GAS WATER HEATER - 100KBTU/HR 0.808 THERM EFF, Use Side Design Flow Rate [m3/s], 5.36265E-005
|
598
|
-
Component Sizing Information, Pump:ConstantSpeed, MAIN SERVICE WATER LOOP CIRCULATOR PUMP, Design Flow Rate [m3/s], 5.36265E-005
|
599
|
-
Component Sizing Information, Pump:ConstantSpeed, MAIN SERVICE WATER LOOP CIRCULATOR PUMP, Design Power Consumption [W], 2.40358
|
600
|
-
Environment:Design Day Data,-16.30,0.00,DefaultMultipliers,Wetbulb,-16.30,{C},98769,270,5.1,0.00,No,No
|
601
|
-
Environment:Design Day Misc, 21,1229.0,0.1415,5.7310E-002,1.0,-11.15,-20.1,ASHRAEClearSky
|
602
|
-
Environment,RUN PERIOD 1,WeatherFileRunPeriod,01/01/2006,12/31/2006,Sunday,365,Use RunPeriod Specified Day,No,No,No,Yes,Yes,Clark and Allen
|
603
|
-
Environment:Design Day Data,30.30,9.30,DefaultMultipliers,Wetbulb,21.80,{C},98769,240,5.7,0.00,No,No
|
604
|
-
Environment:Design Day Misc,202,1084.4,0.2082,0.1365,1.0,-6.23,20.6,ASHRAETau
|
605
|
-
Environment:Design Day Data,-16.30,0.00,DefaultMultipliers,Wetbulb,-16.30,{C},98769,270,5.1,0.00,No,No
|
606
|
-
Environment:Design Day Misc, 21,1229.0,0.1415,5.7310E-002,1.0,-11.15,-20.1,ASHRAEClearSky
|
607
|
-
Environment,RUN PERIOD 1,WeatherFileRunPeriod,01/01/2006,12/31/2006,Sunday,365,Use RunPeriod Specified Day,No,No,No,Yes,Yes,Clark and Allen
|
608
|
-
Environment:Daylight Saving,Yes,InputFile,03/12,11/05
|
609
|
-
Environment:WarmupDays, 16
|
610
|
-
Warmup Convergence Information,CORE_BOTTOM ZN,RunPeriod: RUN PERIOD 1,3.9820116453E-002,2.3811350976E-002,Pass,Pass,0.4861347979,0.4892376047,Pass,Pass
|
611
|
-
Warmup Convergence Information,CORE_MID ZN,RunPeriod: RUN PERIOD 1,1.5205664448E-002,9.8452027670E-003,Pass,Pass,0.4906194600,0.4926882563,Pass,Pass
|
612
|
-
Warmup Convergence Information,CORE_TOP ZN,RunPeriod: RUN PERIOD 1,8.3665472694E-002,8.5797348090E-002,Pass,Pass,6.4128019170,17.5573040278,Pass,Pass
|
613
|
-
Warmup Convergence Information,FIRSTFLOOR_PLENUM ZN,RunPeriod: RUN PERIOD 1,4.5083663650E-002,3.0143228811E-002,Pass,Pass,0.4990380749,0.4753108668,Pass,Pass
|
614
|
-
Warmup Convergence Information,MIDFLOOR_PLENUM ZN,RunPeriod: RUN PERIOD 1,4.9991910380E-002,3.3130325383E-002,Pass,Pass,0.4976143609,0.4824200281,Pass,Pass
|
615
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_1 ZN,RunPeriod: RUN PERIOD 1,0.1806195441,0.2353430972,Pass,Pass,4.3639408916,19.4216753413,Pass,Pass
|
616
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_2 ZN,RunPeriod: RUN PERIOD 1,0.2768100523,0.3312648329,Pass,Pass,21.0378808232,153.0564076187,Pass,Pass
|
617
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_3 ZN,RunPeriod: RUN PERIOD 1,0.3643099230,0.3518729996,Pass,Pass,2.5623200559,12.6516127153,Pass,Pass
|
618
|
-
Warmup Convergence Information,PERIMETER_BOT_ZN_4 ZN,RunPeriod: RUN PERIOD 1,0.3748378725,0.3815629629,Pass,Pass,7.2709540488,20.5681212413,Pass,Pass
|
619
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_1 ZN,RunPeriod: RUN PERIOD 1,0.2418578466,0.2925119711,Pass,Pass,2.6821960522,11.8232318724,Pass,Pass
|
620
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_2 ZN,RunPeriod: RUN PERIOD 1,0.2840150185,0.3455062671,Pass,Pass,5.0580722195,37.0819693491,Pass,Pass
|
621
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_3 ZN,RunPeriod: RUN PERIOD 1,0.3329130737,0.3183975096,Pass,Pass,0.7698192217,0.8424430889,Pass,Pass
|
622
|
-
Warmup Convergence Information,PERIMETER_MID_ZN_4 ZN,RunPeriod: RUN PERIOD 1,0.3514371281,0.3850786375,Pass,Pass,32.0152373066,351.4724853603,Pass,Pass
|
623
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_1 ZN,RunPeriod: RUN PERIOD 1,0.3294175033,0.3944502614,Pass,Pass,3.6710843863,29.4084535434,Pass,Pass
|
624
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_2 ZN,RunPeriod: RUN PERIOD 1,0.4106282386,0.4617091612,Pass,Pass,3.3611389325,13.5895037529,Pass,Pass
|
625
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_3 ZN,RunPeriod: RUN PERIOD 1,0.4729789862,0.4038101023,Pass,Pass,13.1796380202,60.0231906814,Pass,Pass
|
626
|
-
Warmup Convergence Information,PERIMETER_TOP_ZN_4 ZN,RunPeriod: RUN PERIOD 1,0.4930007178,0.5004707991,Pass,Pass,12.4678526142,94.7725767590,Pass,Pass
|
627
|
-
Warmup Convergence Information,TOPFLOOR_PLENUM ZN,RunPeriod: RUN PERIOD 1,0.1321872151,8.9388705468E-002,Pass,Pass,0.4898090947,0.4917409065,Pass,Pass
|
628
|
-
! <Program Control Information:Threads/Parallel Sims>, Threading Supported,Maximum Number of Threads, Env Set Threads (OMP_NUM_THREADS), EP Env Set Threads (EP_OMP_NUM_THREADS), IDF Set Threads, Number of Threads Used (Interior Radiant Exchange), Number Nominal Surfaces, Number Parallel Sims
|
629
|
-
Program Control:Threads/Parallel Sims, No,1, N/A, N/A, N/A, N/A, N/A, N/A
|
630
|
-
End of Data
|